Section II Manual, Setup, Operation and Test
US Patent #7940051
satinAMERICAN
CORPORATION
shelton, ct 1-800-272-7711
www.satinamerican.com
Note: this equipment has been tested and found to comply with the
limits for a class A digital device, pursuant to part 15 of the FCC
rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own
expense.
1.0
Introduction:
WARNING!!
TO PREVENT ELECTRICAL SHOCK OR INJURY, DISCONNECT THE BREAKER FROM
ALL PRIMARY AND SECONDARY POWER SOURCES AND CONFIRM THAT THE
BREAKER IS OPEN AND THE CHARGING SPRINGS ARE DISCHARGED BEFORE
DOING ANY WORK.
revision --,
2-3-12
2.0
Hardware Overview:
1.
1A
1C
1D
1B
1E
1F
1G
1H
ITEM
DESCRIPTION
1A
Reset
1B
1C
Serial number
and date code
Pickup LED
1D
Monitoring
LED
1E
Display
1F
Soft keys
1G
Battery access
1J
Test port
This button projects when the breaker trips on an overcurrent. The breaker will not
reclose until this button is depressed.
revision --,
2-3-12
2C
2B
2A
2I
2H
2D
2G
2F
2E
FIGURE 2,
Bottom view of etc-12Q.series Showing Notable Hardware Features
ITEM
DESCRIPTION
2A
2B
2C
2D
Neutral CT
Phase 1 CT
Phase 2 CT
Phase 3 CT
2E
Auxiliary
2F
MOC
2G
24 V control
power
2H
Flux
2I
TH
revision --,
2-3-12
3A
3B
3C
3D
ITEM
DESCRIPTION
3A
MODBUS
interface
3B
Trip Alarm
3C
Pre-Trip Alarm
3D
Plug-in
terminal block
Requires breaker to have 24VDC control power. Individual units must be assigned a
unique ID through t before they are connected to a network with multiple units. ID
#210 is universal and cannot be polled when multiple units are connected on a
network.
Requires breaker to have 24VDC control power. Normally open contacts change
state when etc-12Q.series initiates a breaker trip. Contacts do not change state
when breaker is open manually or through shunt trip. Contacts are reset by pressing
the CLEAR softkey that appears on the display after a trip. Contacts are also reset
by closing the breaker onto more than 1 phase of current. Contacts are rated at 6A.
250 VAC.
Normally open, optically coupled contacts that change state when current
approaches long-time pickup. Trigger value is factory set at 90% of the long-time
pickup value provided that this current is at least 35% of the breaker CT rating (In).
Value can be field customized through MODBUS port. Contacts are rated at 200mA,
120V.
Terminal block for auxiliary connector. Accepts 16 30 AWG wire.
revision --,
2-3-12
3.0
revision --,
2-3-12
Parameter
Breaker type
Frame Size
Current sensor tap
rating
Long-time pickup
See figure 9.
Short time I t
Short time delay
Instantaneous pickup
May be defeated if
instantaneous is enabled.
May be defeated on H1
and N1 breaker types
provided that short-time is
enabled.
For pickups below 4L,
pickups can be set in
increments of .5L. In all
other cases, pickups can
be set in increments of
1.0L.
Constant or I t
.100, .150, .200, .300, .400, or .500 seconds
revision --,
2-3-12
flashSAFE Ground
fault pickup.
Phase imbalance
pickup
Phase imbalance
delay
Parameter
Frequency
Allow settings
changes when in
service.
Permit activation of
flashSAFE from front
panel.
Permit shunt trip from
front panel.
Permit display of
ground fault current
Range of Settings
Notes
Default
Value
On
Off
May be defeated.
Off
Off
On or Off
May be defeated.
Off
On or Off
May be defeated.
Off
Select or Skip
Off
On or Off
Off
On or Off
Off
On or Off
Off
On or Off
Off
Range of Settings
50 or 60 Hz
Yes or No
Default
Value
60 Hz
No
Yes or No
No
Yes or No
No
Yes or No
No
revision --,
2-3-12
revision --,
2-3-12
S/N:10100
V:06.04.00.02.006Q
QUIT
NEXT
BREAKER TYPE
H1 STANDARD IC
QUIT
SELECT
QUIT
SELECT
FIGURE 9,
NAMEPLATE SHOWING TYPE NUMBER
AND FRAME SIZE
revision --,
2-3-12
SELECT
CURRENT SENSOR
TAP: 2500/0.1 AMPS
QUIT
SELECT
Where:
t = time to trip in seconds
LTD = long time delay expressed in
seconds at 150% of pickup
I = current in amps
LONG-TIME DELAY
48 SEC
@ 1.5X LTP
QUIT
SELECT
revision --,
2-3-12
SELECT
5.9. Short-Time Pickup (STP): If the shorttime band was selected on the previous
screen, the user is then prompted to
enter the short-time pickup on the screen
shown in figure 17. OEM trip units
designate this parameter as Im and it is
expressed as a multiple of the long-time
pickup.
SHORT-TIME PICKUP
10000 AMPS
=4.00 LTP
SELECT
QUIT
Note: The ramped delay of the shorttime I2t curve ends when current
exceeds 10 times LTP. At or above
these currents, the trip time will be a
constant value equal to the short-time
delay setting.
ST DELAY MODE
I^2 ENERGY
QUIT
SELECT
revision --,
2-3-12
SHORT-TIME DELAY
.100 SEC
QUIT
SELECT
INSTANTANEOUS
20000 AMPS
= 8.00 LTP
QUIT
SELECT
GROUND FAULT
ENABLE
QUIT
SELECT
revision --,
2-3-12
SELECT
Note: The ramped delay of the groundfault I2t curve ends when current
exceeds 2 times the sensor rating (In).
At or above these currents, the etc12Q.series will trip at a constant value
equal to the ground-fault delay setting.
SELECT
Where:
t = time to trip in seconds
GFD = ground fault delay, expressed as
time to trip when current is 2x
sensor rating.
IGF = ground fault current in amps
SELECT
revision --,
2-3-12
6.0
Advanced Features:
ADVANCED FEATURES
QUIT
SELECT
SKIP
WARNING!!
flashSAFE settings must be determined by a qualified engineer after short
circuit and arc-flash studies have been completed. Improper settings can
result in injury or death to personnel, equipment damage and nuisance
tripping.
This device is intended to augment an existing safety system and does not
eliminate the need for personnel to be trained and equipped with appropriate
levels of PPE. Refer to NFPA-70E for comprehensive guidelines for workplace
electrical safety.
It is vital that breakers are suitably adjusted and maintained as any advantage
gained by faster response from the trip unit will be negated by improper
mechanical operation.
When properly used, flashSAFE can reduce the arc-flash hazard levels at
locations electrically downstream from where it is applied. Arc-flash danger is
NOT decreased at the breaker flashSAFE is installed OR upstream of the
Instructions for etc-12Q.series retrofit.
device.
page 14 of 20
revision --,
2-3-12
QUIT
FLASHSAFE
SELECT
PICKUP:
=
QUIT
SELECT
GND FAULT:
YES
QUIT
INSTANT
1200 AMPS
1.50 LTP
INSTANT
YES
FLASHSAFE
SELECT
FLASHSAFE
revision --,
2-3-12
PHASE IMBALANCE
YES
QUIT
SELECT
PHASE IMBALANCE
PICKUP: 15%
QUIT
SELECT
PHASE IMBALANCE
DELAY: 10 SEC
QUIT
SELECT
LONG-TIME THERMAL
DISABLE
QUIT
SELECT
revision --,
2-3-12
SELECT
6.8.
QUIT
SELECT
SEND RESTRAINT ON
SHORT-TIME PICKUP
NO
QUIT
SELECT
SEND RESTRAINT ON
GROUND-FAULT PICKUP
NO
QUIT
SELECT
RESTRAIN TRIPS ON
SHORT-TIME BAND
NO
QUIT
SELECT
RESTRAIN TRIPS ON
GROUND-FAULT BAND
NO
QUIT
SELECT
revision --,
2-3-12
OPTIONS MENU
SELECT
WARNING!!
OPTIONS
SKIP
SELECT
FREQUENCY
60 Hz
QUIT
SELECT
ENABLE FLASHSAFE
FROM FRONT PANEL
YES
QUIT
SELECT
revision --,
2-3-12
SELECT
ACTIVATE DISPLAY OF
GROUND FAULT AMPS
NO
QUIT
SELECT
SAVE SETTINGS?
QUIT
SAVE
IMPORTANT!!
RETROFITTED BREAKERS MUST BE
PERFORMANCE TESTED BEFORE
BEING RETURNED TO SERVICE.
PRIMARY INJECTION TESTING IS
STRONGLY RECOMMENDED.
revision --,
2-3-12