Abstract
Safety control and protection strategy of high-voltage system of electric vehicles include analysis of circuit condition
before connection to high voltage terminal, transient current prevention for capacitive load, real-time monitoring and
analysis of high-voltage system during operation, disconnecting strategy of high voltage terminals, vehicle dynamic safety
and cooperative management of electrical systems, etc. Monitoring and analysis of some critical parameters of high
voltage system such as insulation, electrical harness and connector condition are the basis and difficulties in high-voltage
safety and protection. This paper presents several mathematical models of monitoring critical parameters, and experiments
were also done to evaluate the model. Disadvantages of the commonly used calculation method are discussed. Single
point insulation defect model is introduced and diagnosis method of multiple points defect is also discussed. To satisfy
high voltage safety management system based on micro-controller, online diagnosis method of related parameters is
studied. Hardware-in-loop (HIL) and complete vehicle experiment were conducted to prove the validity, response and
reliability of the proposed method.
Keywordshigh-voltage system, On-line monitoring methods,electric vehicles
1 Introduction
Page000233
2.2
R0 Ri R0
With (1) and (2), not only insulation resistance of high
voltage system can be obtained, but also the insulation
weakness can be located by (3a) and (3b)
Ri
R0
(Vb V1 V2 )
V1 V2
V1
U
Vb
V1 V2
(3a)
(3b)
2.4
electrical system
There are two methods to monitor connection condition
of electrical system for propulsion. One is auxiliary low
voltage circuit method and the other is dynamic
electrical parameter method. The first one needs
additional low voltage circuit and the advantage is
accurate measurement on contact resistance of certain
part of the circuit, however high voltage circuit or failure
may cause safety problems.
The second method dynamically variance of contact
resistance of the circuit of which voltage and current are
measured. It simplifies a high voltage system to the
configuration shown in Fig. 3. The battery is considered
to be a constant voltage source E and internal resistance
of Ri in series, R is the sum of wiring resistance and
contact resistance, so we have R+Ri=(E-V)/I. If one
point is taken to be base point which has current of I1
and voltage of V1, measurement at any point with
current I2 and voltage V2 can be used to calculate
instantaneous contact resistance by equation,
R Ri (V1 V2 ) /( I1 I 2 )
2.5
2.3
weakness
Single-point insulation weakness is one of the
phenomenons of insulation degradation. If insulation
Page000234
START
connect AV100 to
port 1 and 3 ,then
get V1av1
connect AV100 to port
2 and 3 ,then get
V2av1
connect port 1 and 3 to
5Mohm resistance ,
connect AV100 to port 2
and 3 ,then get V3av1
connect port 2 and 3 to
5Mohm resistance ,
connect AV100 to port 1
and 3 ,then get V3av2
V1av1=0&V2av1=0&
V3av1+V3av2=V0
YES
YES
Insulation gration;
measure insulation
resistance by LV28-P
V1av1V2av1?
NO
V3av1+V3av2<V0
YES
multiple points
insulation degration;
save the data
connect LV28-P to
port 1 and 3 ,then
get V1v280
NO
connect LV28-P to
port 2 and 3 ,then
get V1v280
END
NO
V1av1!=0|
V2av1!=0
YES
connect LV28-P to
port 1 and 3 ,then
get V1v281
connect LV28-P to
port 2 and 3,then
get V1v282
NO
data error
END
END
master
contactor
switch-off
master
contactor
part
voltage
of + to
bodywork
V
voltage
of - to
bodywork
V
total+
120.12
1.81
total-
123.24
grouped
56.16
63.96
total+
120.12
1.86
total-
123.56
grouped
57.72
63.74
total+
total-
grouped
idem
idem
idem
idem
idem
idem
switch-on
no-load
30km/h
result
R=52.3k
U=281.3V
R=51.3k
U=0V
R=53.7k
U=133.5V
R=52.2k
U=280.9.3V
R=51.4k
U=0V
R=52.6k
U=130.8V
Page000235
Page000236
abnormal
points
bus
current/A
contact resistance
calculated by
current base point
of 2.4A/m
4949~4952
120.3
348~357
-4000~-3330
4953~4957
112.9
362~380
847~1695
4958~4961
120.3
383~393
476~544
4973
87.9
473
-54.7
5010
83.3
418
-84.5
6445~6449
17.2
2162~2297
127~148
7027~7058
113.1
433~451
-175~-520
7791
118.5
508
-4000
analyse
calculated normally
by current base point
of 2.4A
calculated normally
by current base point
of 2.4A
calculated normally
by current base point
of 2.4A
calculated normally
by current base point
of 2.4A
calculated normally
by current base point
of 2.4A
calculated normally
by current base point
of 118.9A but
smaller(influenced by
SOC)
calculated normally
by current base point
of 2.4A
calculated normally
by current base point
of 2.4A
power
off
power
on
switch-off
bus
curre
nt/A
switch-on
+11.70
switch-off
-0.002
switch-on
+11.63
switch-on
switch-on
switch-on
switch-on
2.3
3
4
10
+11.69
+11.69
+11.64
+11.59
switch-on
15
+11.66
contactor
voltage of
measure point/V
-0.001
Page000237
5 conclusion
The mathematical model of diagnosis method for several
critical condition is studied and validated with experiment.
To satisfy the requirement of failure diagnosis and high
voltage safety management based on microprocessor,
online diagnosis strategy is studied and its effectiveness,
response and reliability are validated in hardware-in-loop
and actual vehicle test.
Authors
Professor level senior engineer, Zhao chunming
China Automotive Technology And Research Center,
Tel: 13920025865
Fax: 022-66320013-6615
Email:zhaochunming@catarc.ac.cn
assistant engineer, Li qing
Tianjin Qingyuan Electric Vehicle Co.Ltd
Tel: 15900343194
Fax: 022-66320013-6615
Email:lq@qyev.com
4.2
15
25
35
140
304.8
301.4
299.2
297.8
276.8
17
3122