Pump Catalog
Number Product Description
Flow range 0.1-40 ml/min
731-8300 Standard BioLogic LP System, 110/120 V,
Maximum counterpressure 30 psi (2 bar) includes BioLogic LP Controller, BioLogic Rack,
Gradient formation Solenoid-activated proportioning valve. and Accessory Kit containing inject valve (MV-6),
Mixer volume ~750 µl proportioning valve/mixer, (Econo) UV optics,
conductivity cell, tubing and fittings kit, user manual,
starter kit and conductivity cell/column holder
Detection Performance
731-8301 Standard BioLogic LP System, same as 731-8300 except 220/240 V
UV Single channel, 280/254 nm with auto zero.
Detection range: 0.001-2 AUFS 731-8302 BioLogic LP System with 2110 Fraction Collector, 110/120 V,
includes BioLogic LP Controller, BioLogic Rack,
Conductivity Detection range: 0.5-500 mS/cm FS and Accessory Kit containing inject valve (MV-6),
proportioning valve/mixer, (Econo) UV optics, conductivity
Temperature Range 4-40 °C cell, tubing and fittings kit, user manual, starter kit and
conductivity cell/column holder, plus Model 2110
Fraction Collector.
Sample loading Manual loop fill
Automatic loading through SV-5 731-8303 BioLogic LP System with 2110 Fraction Collector, 220/240 V
Buffer Select Valve 731-8304 BioLogic LP System with 2128 Fraction Collector, 110/120 V,
includes BioLogic LP Controller, BioLogic Rack, and Accessory
Kit containing Inject valve (MV-6), proportioning valve/mixer,
Fraction Collector Specifications (Econo) UV optics, conductivity cell, tubing and fittings kit,
user manual, starter kit and conductivity cell/column holder,
plus Model 2110 Fraction Collector.
Model 2110 Fraction Collector
731-8305 BioLogic LP System with 2128 Fraction Collector, 220/240 V
Capacity Eighty 13 x 100 mm glass, polypropylene,
or polystyrene test tubes, or 1.5 ml micro test 731-8306 BioLogic LP System with 2110 Fraction Collector
tubes when using optional adaptor and chart recorder, 110/120 V, includes BioLogic LP Controller,
BioLogic Rack, and Accessory Kit containing Inject valve
Collection basis 1-999 drops in 1 drop increments
(MV-6), proportioning valve/mixer, (Econo) UV optics,
0.05-9.99 minutes in 0.01 minute increments
conductivity cell, tubing and fittings kit, user manual,
10.0-99.9 minutes in 0.1 minute increments
starter kit and conductivity cell/column holder, plus
Materials of construction Case and carousel: polypropylene Model 2110 Fraction Collector and Model 1327 Chart Recorder.
Front panel: hard-coated polycarbonate
731-8307 BioLogic LP System with 2110 Fraction Collector
Drop former: silicone rubber
and chart recorder, 220/240 V
Waste outlet tube: polyurethane
731-8308 BioLogic LP System with 2128 Fraction Collector
Operating temperature 4-40 ˚C
and chart recorder, 110/120 V, includes BioLogic LP Controller,
Dimensions 24 x 33 x 25 cm (W x D x H) BioLogic Rack, and Accessory Kit containing Inject valve
(MV-6), proportioning valve/mixer, (Econo) UV optics,
Safety certification Meets I.E.C. 1010 and C.S.A. 22.2
conductivity cell, tubing and fittings kit, user manual,
Model 2128 Fraction Collector starter kit and conductivity cell/column holder, plus
Model 2110 Fraction Collector and Model 1327 Chart Recorder.
Fractionation Time, drop or volume
Time: 0.03-99.9 min in 0.1 min units 731-8309 BioLogic LP System with 2128 Fraction Collector
Drop: 0-999 drops and chart recorder, same as 731-8308 except 220/240 V
Bio-Rad
Laboratories
Life Science Group U.S. (800) 4BIORAD California (510) 741-1000 Australia 02-9914-2800 Austria (1)-877 89 01 Belgium 09-385 55 11 Canada (905) 712-2771 China (01) 2046622 Denmark 39 17 9947
Finland 90 804 2200 France (1) 49 60 68 34 Germany 089 31884-0 Hong Kong 7893300 India 91-11-461-0103 Italy 02-21609 1 Japan 03-5811-6270 The Netherlands 0318-540666
New Zealand 09-443 3099 Singapore (65) 272-9877 Spain (91) 661 70 85 Sweden 46 (0) 8 627 50 00 Switzerland 01-809 55 55 United Kingdom 0800 181134 SIG 072296
(P)96-0155 REV.A 796 Bulletin 2038