Vous êtes sur la page 1sur 11

PROJECT INFORMATION

Building Analysis Data


Length of Building

12.52

Width of Building

12.00

Height of Building

10.35

Basic Wind Speed (V)


Topographic Location

45.00

m/s

Ground Roughness

1.00

from Section 5.5.1 of CP 3: Chapter V Part 2

from Section 5.5.2 of CP 3: Chapter V Part 2

Cladding & Building Size Class


S3 - Multiplying Factor Relating to Life of Structure

1.00

Cf

0.95

Calculate and View Result


Table 2 or Section 5.4
Table 3
Section 5.5.1
Section 5.5.2
Tabe 10 force coefficient

from Section 5.4 0r Table 2 of CP 3: Chapter V Part 2

from Figure 2 of CP 3: Chapter V Part 2


Force Coefficient from Table 10

of CP 3: Chapter V Part 2

Chapter V Part 2

Chapter V Part 2

WIND LOAD CALCULATION


Wind Analysis Data for CP3 Chapter V Part 2
Length of Building

12.5200

Width of Building

12.000

Height of Building

10.350

Basic Wind Speed (V)


Topographic Location

45.00
A

m/s
from Section 5.4 0r Table 2 of CP 3: Chapter V Part 2

Ground Roughness

1.00

from Section 5.5.1 of CP 3: Chapter V Part 2

from Section 5.5.2 of CP 3: Chapter V Part 2

Cladding & Building Size Class


Wind Pressure Calculation
Wk

Vs

0.613 Vs2
V S1 S2 S3

S1

1.00

( from Section 4.3 of CP 3: Chapter V Part 2 )


Multiplying Factor Relating to topology

S2

1.03

( from Table 2 of CP 3: Chapter V Part 2 )


Multiplying Factor Relating to Height above Ground & Wind Breaking

S3

1.00

( from Table 3 of CP 3: Chapter V Part 2 )


Multiplying Factor Relating to Life of Structure

Vs

46.35

m/s

Wk

1316.922

N/m2

Wk

1.317

kN/m2

0.950

1.251

kN/m2

1.251

kN/m 2

Characteristic Wind Pressure (N/m 2 )


Design Wind Speed (m/s)

( from Figure 2 of CP 3: Chapter V Part 2 )

Wind Load Calculation


Cf
Cf Wk

Force Coefficient

Design Wind Pressure Cf.Wk


Cf.Wk

WIND LOAD CALCULATION


Design Wind Pressure Cf.Wk
Cf.Wk

kN/m 2

1.251

DIRECTION 1 +
Height
STOREY 1
STOREY 2
STOREY 3
STOREY 4

Width

Area

Force

LOWER

0.2

12.52

2.504

3.133

UPPER

1.65

12.52

20.658

25.845

LOWER

1.65

12.52

20.658

25.845

UPPER

1.65

8.514

14.0481

17.575

LOWER

1.65

8.514

14.0481

17.575

UPPER

1.5

7.35

11.025

13.793

LOWER

1.5

7.35

11.025

13.793

UPPER

0.25

7.35

1.8375

2.299

Total Force

Location

28.977

6.260

43.420

5.449

31.368

4.001

16.092

3.675

Total Force

Location

28.977

6.260

43.420

5.449

31.368

4.001

16.092

3.675

Total Force

Location

27.774

6.000

49.543

6.000

36.031

5.063

13.136

3.000

Total Force

Location

27.774

6.000

49.543

6.000

36.031

5.063

13.136

3.000

4
3
2
1

DIRECTION 1 Height
STOREY 1
STOREY 2
STOREY 3
STOREY 4

Width

Area

Force

LOWER

0.2

12.52

2.504

3.133

UPPER

1.65

12.52

20.658

25.845

LOWER

1.65

12.52

20.658

25.845

UPPER

1.65

8.514

14.0481

17.575

LOWER

1.65

8.514

14.0481

17.575

UPPER

1.5

7.35

11.025

13.793

LOWER

1.5

7.35

11.025

13.793

UPPER

0.25

7.35

1.8375

2.299

4
3

DIRECTION 2 +
Height
STOREY 1
STOREY 2
STOREY 3
STOREY 4

Width

Area

Force

LOWER

0.2

12

2.4

3.003

UPPER

1.65

12

19.8

24.771

LOWER

1.65

12

19.8

24.771

UPPER

1.65

12

19.8

24.771

LOWER

1.65

12

19.8

24.771

UPPER

1.5

11.260

LOWER

1.5

11.260

UPPER

0.25

1.5

1.877

DIRECTION 2 Height
STOREY 1
STOREY 2
STOREY 3
STOREY 4

Width

Area

Force

LOWER

0.2

12

2.4

3.003

UPPER

1.65

12

19.8

24.771

LOWER

1.65

12

19.8

24.771

UPPER

1.65

12

19.8

24.771

LOWER

1.65

12

19.8

24.771

UPPER

1.5

11.260

LOWER

1.5

11.260

UPPER

0.25

1.5

1.877

1&2

WIND LOAD CALCULATION


Wind Analysis Data for CP3 Chapter V Part 2

A or B
3.269 m2
0.958 m2

5.821 m2

4.227 m2

cf.wk x Area(A)
7.300 kN
C or D

cf.wk x Area(A)
5.300 kN

1.375

4.563 m2
1.258 m2

2.45

A or B

C or D

3.637 m2
0.000 m2

2.606 m2
0.000 m2

3.637 m2

2.606 m2

4.600 kN

3.300 kN

2.125

Dir2

0.15

Dir1

0.50 0.40

OPTION 1: CONCENTRATED LOAD ON BEAM-COLUMN JOINT

Dir2

1.258 m2
cf.wk x Area(A)
1.600 kN
A or B
2.645 m
cf.wk x width(A)
3.400 kN/m

A or B (Parapet)
0.958 m2
cf.wk x Area(A)
1.200 kN
A or B

2.45

A or B (Parapet)

1.895 m
cf.wk x width(A)
2.400 kN/m

0.15

Dir1

0.50 0.40

OPTION 2: UNIFORMLY DISTRIBUTED LOAD ON COLUMN

A
9.125 m2
2.516 m2

6.538 m2
1.916 m2

11.641 m2

8.454 m2

cf.wk x Area(A)
14.600 kN

cf.wk x Area(A)
10.600 kN
B

7.274 m2
0.000 m2

5.211 m2
0.000 m2

7.274 m2

5.211 m2

cf.wk x Area(A)
9.200 kN

cf.wk x Area(A)
6.600 kN

B
0.15

2.45

2.125

Dir2

1.375

Dir1

0.50 0.40

OPTION 3: CONCENTRATED LOAD ON THE CENTER OF BUILDING WIDTH PER FLOOR

Topography Factor
Topography
Value of S1
a
1
b
1.1
c
0.9
Topographic Location
a
All cases except those in b and c
b
Very exposed hill slopes and crests where
acceleration of the wind is known to occur
c
steep sided, enclosed valleys sheltered fromm all winds

GO TO DATA INPUTS

(1) Open Country with No Obstructions


Height

1
2
3
5
10
15
20
30
40
50
60
80
100
120
140
160
180
200

0.83
0.83
0.83
0.88
1
1.03
1.06
1.09
1.12
1.14
1.15
1.18
1.2
1.22
1.24
1.25
1.26
1.27

0.78
0.78
0.78
0.83
0.95
0.99
1.01
1.05
1.08
1.1
1.12
1.15
1.17
1.19
1.2
1.22
1.23
1.24

0.73
0.73
0.73
0.78
0.9
0.94
0.96
1
1.03
1.06
1.08
1.11
1.13
1.15
1.17
1.19
1.2
1.21

(2) Open Country with


Scattered Windbreaks
Height
A
B
1
2
3
5
10
15
20
30
40
50
60
80
100
120
140
160
180
200

0.72
0.72
0.72
0.79
0.93
1
1.03
1.07
1.1
1.12
1.14
1.17
1.19
1.21
1.22
1.24
1.25
1.26

Height of Building

10.35

Height of Building

Cladding & Building Size Class

15
A

Ground Roughness

1.00

s2

1.03

0.67
0.67
0.67
0.74
0.88
0.95
0.98
1.03
1.06
1.08
1.1
1.13
1.16
1.18
1.19
1.21
1.22
1.24

C
0.63
0.63
0.63
0.7
0.83
0.91
0.94
0.98
1.01
1.04
1.06
1.09
1.12
1.14
1.16
1,18
1.19
1.21

(3) Country with many windbreaks;


Small towns; outskirts of large cities
Height
A
B
C
1
2
3
5
10
15
20
30
40
50
60
80
100
120
140
160
180
200

Ground Roughness
1
1.03
2
1
3
0.88
4
0.74

0.64
0.64
0.64
0.7
0.78
0.88
0.95
1.01
1.05
1.08
1.1
1.13
1.16
1.18
1.2
1.21
1.23
1.24

0.6
0.6
0.6
0.65
0.74
0.83
0.9
0.97
1.01
1.04
1.06
1.1
1.12
1.15
1.17
1.18
1.2
1.21

0.55
0.55
0.55
0.6
0.69
0.78
0.85
0.92
0.96
1
1.02
1.06
1.09
1.11
1.13
1.15
1.17
1.18

(4) Surface with large and frequent


obstructions, e.g. city centes
Height
A
B
C
1
2
3
5
10
15
20
30
40
50
60
80
100
120
140
160
180
200

0.56
0.56
0.56
0.6
0.67
0.74
0.79
0.9
0.97
1.02
1.05
1.1
1.13
1.15
1.17
1.19
1.2
1.22

GO TO DATA INPUTS

0.52
0.52
0.52
0.55
0.62
0.69
0.75
0.85
0.93
0.98
1.02
1.07
1.1
1.13
1.15
1.17
1.19
1.21

0.47
0.47
0.47
0.5
0.58
0.64
0.7
0.79
0.89
0.94
0.98
1.03
1.07
1.1
1.12
1.14
1.16
1.18

GROUND ROUGHNESS CATEGORY


Ground Roughness 1

Long fetches of open, level or nearly level country with no shelter.


Examples are flat coastal fringes, fens, airfields and grasslands,
moorland or farmland without hedges or walls around the fields.

Ground Roughness 2

Flat or undulating country with obstructions such as hedges or walls


around fields, scattered windbreaks of tress and occasional buildings.
Examples are most farmland and country estates with the exception
of those parts that are well wooded.

Ground Roughness 3

Surfaces covered by numerous large obstructions.


Examples are well-wooded parkland and forest areas, towns and their
shrubs, and their suburbs, and the outskirts of large cities. The general
level of rooftops and obstructions is assumed at about 10m, but the
category will include built-up areas generaaly apart from those that
qualify for category 4.

Ground Roughness 4

Surfaces covered by numerous large obstructions with a general


roof height of about 25 m, or more. This category covers onty the
centres of large towns and cities where the buildings are not only
high, but are also bot too widely spaced,

GO TO DATA INPUTS

CLADDING AND BUILDING SIZE CATEGORY


CLASS

All units of cladding, glazing and roofing and their immediate


fixings and individual members of unclad structures

CLASS

All buildings and structures where neither the greatest horizontal


dimension nor the greatest vertical dimension exceeds 50 m (165ft).

CLASS

All buildings and structures whose greatest horizontal dimension


and greatest vertical dimension exceeds 50 m (165ft).

GO TO DATA INPUTS

L/W
4
3
2
1.5
1

h/b HEIGHT OVER BREADTH RATIO


cf FORCE COEFFICIENT
1
2
4
6
10
1.3
1.4
1.5
1.6
1.6
0.7
0.75
0.75
0.75
0.75
1.2
1.25
1.35
1.4
1.4
0.75
0.75
0.75
0.8
0.8
1.05
1.1
1.15
1.2
1.2
0.75
0.8
0.85
0.9
0.9
1
1.05
1.1
1.15
1.15
0.85
0.9
0.95
1
1
0.95
1
1.05
1.1
1.2

b/d
>4
<1/4
3
1/3
2
1/2
1.5
2/3
1

0.5
1.2
0.7
1.1
0.7
1
0.75
0.95
0.8
0.9

cf

GO TO DATA INPUTS

0.95

20
1.6
0.75
1.4
0.8
1.2
0.9
1.15
1
1.4

PROJECT INFORMATION
Building Analysis Data
Length of Building

12.52

Width of Building

12.00

Height of Building

10.35

Basic Wind Speed (V)


Topographic Location

45.00

m/s

Ground Roughness

1.00

from Section 5.5.1 of CP 3: Chapter V Part 2

from Section 5.5.2 of CP 3: Chapter V Part 2

Cladding & Building Size Class


S3 - Multiplying Factor Relating to Life of Structure

1.00

Cf

0.95

from Section 5.4 0r Table 2 of CP 3: Chapter V Part 2

from Figure 2 of CP 3: Chapter V Part 2


Force Coefficient from Table 10

Calculate and View Result

Table 2 or Section 5.4

Table 3

Section 5.5.1

Section 5.5.2

Table 10 force coefficient

Vous aimerez peut-être aussi