CellaTemp PK 18
The CellaTemp PK 18 comes with an especially resilient lens,
allowing its use even in extreme environmental conditions,
such as in asphalt and concrete mixing plants, preventing the
lens from damage caused by aggressive vapours and dust.
Compact pyrometers
CellaTemp PK 29
Type
Temp. range
The CellaTemp PK 29 is equipped with a special UV blocking filter, thus avoiding that the measurement is affected by
daylight. This pyrometer also responds in a substantially less
sensitive way to reflective external radiation from nearby hot
objects than conventional devices working at short wavelengths. Therefore, the CellaTemp PK 29 can be used for a
variety of applications in the metal-working industry and, in
particular, for temperature measurements of aluminium and
bright metals at low temperatures. Thanks to the UV blocking
filter, it is also suitable to measure processes where diodes,
Nd:YAG or CO2 lasers are used for heating. This high-energy
laser radiation does not affect the measurement.
Application
PK 11
0 - 1000 C
nonmetals
PK 12
-30 - 1300 C
PK 14
0 - 1500 C
large objects
PK 18
0 - 1500 C
nonmetals in an aggressive
environment
PK 21
250 - 1600 C
metals, ceramics,
molten glass
PK 29
150 - 1800 C
PK 31
500 - 2500 C
PK 41
300 - 1300 C
glass surfaces
PK 42
500 - 2500 C
glass surfaces
PK 51
400 - 1400 C
flame-heated furnaces
CellaTemp PK 41 / 42
In the range of 4.5 - 8 m glass has an emissivity of almost
100%. Above 5 m, atmospheric influences, such as humidity or water vapour, have an adverse influence on the measurement readings. The CellaTemp PK 41/42 is provided with a
blocking filter with a spectral sensitivity of 4.5 - 4.8 m. allowing
it to measure the temperature from the near surface area of the
glass. Owing to its wavelength, changes in thickness, different
types of glass, or varying moisture contents in the atmosphere
do not affect the measurement reading.
CellaTemp PK 51
The CellaTemp PK 51 was developed especially for temperature measurements in flame heated furnaces. Thanks to the
selective spectral range of 3.9 m, water vapour and CO2 in
the pyrometers field of vision have no effect on the measuring results, even when measuring from large distances. This
allows for precise measurements through flames and combustion gases.
CellaTemp PKF 26 / 36
Type
Temp. range
Application
PKF 26
300 - 1600 C
metals, ceramics,
molten glass
PKF 36
550 - 2500 C
Test function
LED for C / F
Plug M12
M30 thread
7- segment
LED display
3 control keys
Service function
Function
The radiation thermometer CellaTemp
PK detects the infrared radiation emitted by an object and converts it into
an electric signal. The detected temperature is displayed and transmitted
to the analogue output for further processing.
A unique combination of analogue
and digital linearization features
provides the CellaTemp PK with a
high-resolution signal processing unit.
Therefore, even with wide measuring
ranges, the sensor has a very high
temperature resolution while its noise
equivalent temperature difference is
extremely low. The pyrometer thus
supplies stable measurement readings even when the response times
are extremely short and the measured
temperatures are very low.
A microprocessor with high clock
speed allows for short response times
starting at 2ms.
The very bright display unit is equipped
with state-of-the-art technology. Even
from a great distance it is easy to read
and it is energy-efficient at the same
time.
Analogue output
Switching output
The presence of a hot object in the
sensors field of vision triggers a
switching operation when a pre-defined temperature threshold is exceeded. An LED indicates this switching status.
Optionally, the output can operate as
a normally closed or normally open
contact.
This configurable switch on/switch off
delay allows for a suppression of short
interference pulses and for an ideal
adaptation of the switching output to
the response time of a PLC.
Diagnostic function
The diagnostic function ensures a
high operational reliability. Incorrect
supply voltages, reverse polarities of
connections, overloads at the switching output, unacceptable ambient
temperatures or out-of-range object
temperatures appear on the display
as error messages.
Optical system
The optical system of the CellaTemp
PK is equipped with lenses with anti-reflective coatings. This makes the
lenses very durable, easy to clean
and perfectly suitable for rough industrial use.
The excellent imaging characteristics
of the precision lenses provide a high
optical resolution and a minimum sensitivity to stray light. This keeps the
measurement reading stable even
when object sizes and distances
change.
Laser module
During setup of the CellaTemp PKF
26/36 the laser module PS 01/P is
mounted to the end of the fibre optic
cable to adjust the sensors focussing
range and to perform an alignment to
the target.
Technical data
Resolution
Current output
0.2 K + 0.03 % of selected range
Display
0.1 K for T < 200 C
1 K for T 200 C
Voltage supply
18 ... 32 V DC
Current consumption
50 mA at 24 V DC
without load current
Ambient temperature
0 - 65 C
Storage temperature
-20 - +80 C
Permissible humidity
95 % r.H. max.
(non-condensing)
Protection
IP65 according to DIN 40050
Protection class III
Housing material
V2A (1.4305)
Connectivity
M12 thread 5-pin connection
A-coding (DIN EN 61076-2-101)
Weight
approx. 0.4 kg
Adjustable parameters
Outputs
Analogue output
0/4 - 20 mA linear according to
NAMUR 43, scalable
Load max. 500
Switching output
PNP open collector active from
supply voltage (positive)
NC or NO contact
Current rating150 mA
timed safety shutdown at
overload 250 mA
Reverse polarity protection
for supply voltage
for analogue output
for switching output
Test input
Digital input
Typ 3 (IEC 61131-2)
Low level 5 V DC
High level 11 V DC
Load current 11.6 mA at 30 V DC
Display
LED display
4 x 7 segments, red
Height of digits 8 mm
1 x LED
Display of switching status,
overload and incorrect connection
of supply voltage
Analogue output
0/4 - 20 mA
Scaling of analogue output
Switching output
Switching point and reset point
Switching function:
NC / NO contact
Switch on/switch off delay
General parameters
Quick emissivity setting via
temperature display
Damping time constant
Hold time of peak picker
Reset to factory default setting
Key lock
Display
Temperature unit C / F
Temperature simulation
Test function
Error diagnostic
Output overload
Sensor excess temperature
Out-of-range (high/low)
Incorrect supply voltage connection
Incorrect supply voltage
Pin assignment
2 x LED
Display of temperature unit
(C or F)
Approvals
EMC
EN 61000-6-4
EN 61000-6-2
Shock resistance (EN 60068-2-27)
30 g (11 mg)
Vibration resistance (EN 60068-2-6)
5 g (10...2000 Hz)
Operating elements
3 control keys
Weight
LWL-2HT
2m
0.08 kg
LWL-5HT
5m
0.19 kg
LWL-10HT
10 m
0.38 kg
Type
It is imperative to use
a shielded cable
Shipment includes
Radiation thermometer
Operating manual
2 Mounting nuts
Additionally with CellaTemp PKF
Measuring head
Laser module PS 01/P
Fibre optic cable
(state required length)
Type
Temp.
range
Spectral
range
Focus
range
Spot size
Precision*
Response Repeatability
time t 98
Temperature
coefficient
0 - 1000 C
32 - 1832 F
0.3 m
11 mm
PK 12 AF 1
-30 - 300 C
-22 - 572 F
0.3 m
19 mm
8 - 14 m
60 ms
0.75% of temp.
reading [C]
plus 2.0 K
90 ms
PK 14 AF 1
0 - 500 C
32 - 932 F
1.0 m
0.5 m
60 ms
PK 18 AF 1
0 - 500 C
32 - 932 F
0.3 m
11 mm
60 ms
PK 21 AF 1
250 - 1600 C
482 - 2912 F
1.0 1.7 m
1.5 m
12 mm
0.3% of temp.
reading [C]
plus 2.5 K
2 ms for
T > 600 C
PK 29 AF 1
150 - 800 C
302 - 1472 F
1.8 2.2 m
0.3 m
7.5 mm
0.5% of temp.
reading [C]
plus 2.5 K
2 ms for
T > 300 C
PK 31 AF 1
500 - 2500 C
932 - 4532 F
0.78 1.06 m
1.5 m
9 mm
0.2% of temp.
reading [C]
plus 2.5 K
2 ms for
T > 900 C
PK 41 AF 1
300 - 1300 C
572 - 2372 F
12 mm
0.5% of temp.
reading [C]
plus 2.5 K
4.6 4.9 m
PK 42 AF 1
500 - 2500 C
932 - 4532 F
PK 51 AF 1
400 - 1400 C
752 - 2552 F
3.8 4.0 m
0.4 m
0.4 m
8.5 mm
1.0% of temp.
reading [C]
12 mm
1.0% of temp.
reading [C]
1K
0.1 K/K
(fr T < 250 C)
0.04 %/K
(fr T > 250 C)
1K
0.07 %/K
1K
0.07 %/K
2K
100 ms
0.04 %/K
4K
100 ms
2K
0.04 %/K
2K
0.07 %/K
300 - 1600 C
572 - 2912 F
1.0 1.7 m
180 : 1
0.3% of temp.
reading [C]
plus 2.5 K
0.2 m ...
PKF 36 AF 1
550 - 2500 C
1022 - 4532 F
0.78 1.06 m
190 : 1
2 ms for
T > 600 C
2 ms for
T > 900 C
Dimensions
Lengths of compact pyrometers
Compact pyrometer
Length
Type
PK 11
PK 12
183 mm
PK 14
PK 18
PK 21
PK 29
208 mm
PK 31
PK 41
PK 42
199 mm
PK 51
M30x1,5
34,5 mm
67,9 mm
Target diagram1
CellaTemp PK 11 / 18
CellaTemp PK 12
Target diameter [mm]
13
11
20
29
39
48
57
66
75
100
200
300
400
500
600
700
800
900 1000
259
350
442
18
18,5
19
31
44
56
68
81
93
105
2000 3000
4000
5000
100
200
300
400
500
600
700
800
900
1000 2000
167
230
350
475
600
CellaTemp PK 14
CellaTemp PK 21
Target diameter [mm]
100
150
200
250
300
350
400
450
500
1000
12
12
12
12
12
12
100
200
300
400
500
600
700
800
900
1000 2000
100
200
300
400
500
1000
12
20
1500
2000
28
2500 3000
36
44
52
60
68
3500
4000
4500
5000
Target diagram1
CellaTemp PK 29
CellaTemp PK 31
Target diameter [mm]
100
280
400
505
14,6
14,2
13,8
13,4
13
11
2000 3000
4000
5000
100
200
300
400
500
1000
190
14
10,5
21
32
42
53
63
74
84
200
300
400
500
600
700
800
900 1000
12
20
28
35
43
50
100
200
300
400
500
600
700
800
900
134
58
1000 2000
209
285
16
13
11
8.5
15
22
28
35
42
100
200
300
400
500
600
49
57
65
3500
4000
4500
5000
700
800
900
48
115
181
247
1000 2000
313
CellaTemp PKF 26 2
CellaTemp PKF 36 2
Target diameter [mm]
11
17
22
28
33
39
44
50
56
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
D = 190:1
10.5
16
21
26
31.5
37
42
47
52.5
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
2500 3000
360
2000
41
33
16
1500
25
CellaTemp PK 42
17
17
CellaTemp PK 41 / 51
D = 180:1
Taking into account the lens tolerances at 90% of the maximum amount of radiated energy.
The specified target spot diameter is valid for the specified distance.
Supplementary lenses
An additional lens can be mounted onto the pyrometers lens
system to capture smaller target spots.
Pyrometer
Supplementary lens
Distance
[mm]
Spot size
[mm]
PK 11
PK 11/E AF 1
45
PK 21 / 31
PK 21/E AF 1
520
Pyrometer PK
Supplementary lens
7
Accessories
shielded cable
VK 02 / L AF 1: 15 m
VK 02 / L AF 2: 10 m
Laser pointer
PS 01/M AF 3
Laser pointer
PS 01/P
Air purge
PS 01/A
Air purge
PS 01/A AF 2
Oscillating mirror
PZ 20/X AF 5
Thermal insulating
tube PS 01/K
Cooling jacket
PS 01/B AF 2
Bayonet coupling
PS 11/N AF 4
90 Deflection mirror
PS 11/W
Supplementary tube
ZA 01/Q-35
Intermediate tube
ZA 01/M
Intermediate tube
ZA 01/B
Intermediate tube
ZA 01/Q AF 2
Mounting bracket
PS 11/U
Flange
PS 01/N
Flange
ZA 01/I
Flange
ZA 01/W
Flange
DN 50
Tube cap
ZA 01/A
Bracket
PS 11/P
Ball flange
ZA 01/D
Supplementary lens
PK 11/E (for PK 11)
PK 21/E (for PK 21/ 31)
Protective lens
PS 01/I AF 2 (quartz)
PS 15/I (sapphire)
PS 11/D AF 2 (ZnS)
Typical assemblies
Applications
Crystal growing
Coke oven
Runner
Incineration plant
Rolling mill
Power plant
Continuous casting
Rotary kiln
Sinter plant
Glass production
Induction heating
10
Other products
Portix Series
Almost indestructible, portable
pyrometers with rugged aluminum
housing for universal, rapid
measurement.
CellaPort Series
Portable one- and two-colourpyrometers with through-the-lens
sighting, laser pilot light and
USB port.
CellaTemp PA
Versatile pyrometers with focusable
lens, through-the-lens sighting/ laser
spotlight or video camera.
CellaTemp PA-LWL
Versatile fiber optics pyrometers with
focusable head and laser spotlight.
CellaTemp PZ
Profibus pyrometers with focusable
lens, through the lens sighting or
laser spotlight.
Mikro PV
Intensity comparison pyrometer for
ultra accurate measurement.
CellaTemp PM
Ultra miniature pyrometers
for very small spaces.
CellaSwitch
Compact infrared switch with LED
display and auto-diagnostics.
CellaSwitch-LWL
Compact fiber optics infrared
switch with LED display and autodiagnostics.
11
China
www.keller-msr.cn
Tel. +86 (10) 82 86 79 20
keller@germantech.com.cn
www.keller-msr.com
Tel. +49 (0) 54 51 85 0
Fax +49 (0) 54 51 89 73 92
info@keller-msr.de
France
www.keller-msr.fr
Tel. +33 (0) 9 51 45 30 50
france@keller-msr.de
India
www.earthtekniks.com
Tel. +91 (44) 27 46 37 47
pav@keller-msr-asia.com
Russia
www.keller-msr.ru
Tel. +7 (495) 664 27 84
info@keller-msr.ru
Foreign Distributors