DESIGN OF WALL FOOT

For Wall Footings Applied with Concentric Loads, Lat

DESIGN CRITERIA

Wall Thickness, t
Height of Soil above the footing, hs

300.00 mm
740.00 mm

Thickness of the Footing, hc


Concrete Cover
Diameter of Main Reinforcements
Eccentricity of Lateral Loads, e

477.50
75.00
25.00
300.00

Effective depth of the Footing, d


Depth of Embedment, D

mm
mm
mm
mm

390.00 mm
1,217.50 mm

FOOTING DIMENSION DETERMINATION


Effective Soil Pressure, qe
Required Width of Footing, B

FOOTING THICKNESS ADEQUACY

Width of Footing, B
2,200.00 mm
176.70 kPa
2,200.00 mm

REMARKS
Adequate

From the Actual Soil Pressure Diagram


Minimum Actual Soil Pressure, qumin

240.00 kPa

Maximum Actual Soil Pressure, qumax

240.00 kPa

Actual Soil Pressure @ Critical Section, qu1

240.00 kPa

Actual Soil Pressure at the Face of Wall, qu2

240.00 kPa

Check for One-Way Shear / Beam-Action Failure


Shear Capacity, Vn
Actual Shear @ Critical Section, Vu1

263.12 kN/m
134.40 kN/m

BEARING REINFORCEMENT
Diameter of Bars for Dowels
Yield Strength of Dowels
Bearing Strength, Pnb
At Wall
At Footing
Ultimate Bearing Capacity, Pn
Remarks
Minimum Dowel Requirement
Minimum Area of Dowel Reinforcement
No. of Bars
Spacing

REMARKS
Dowels are NOT Required
25.00
280.00
4,641.00
4,641.00
9,282.00

mm
Mpa
kN/m
kN/m
kN/m

528.00 kN/m
Dowels are NOT Required

1,500.00 mm2
4 pcs
900.00 mm

Spacing Requirements as Specied by the Code


Minimum Clear Spacing, Smin
25.40 mm
db
4/3(Max. Aggregate)
25mm
Remarks
Dowel Requirement (If Dowels are REQUIRED)
Excess Load, Pe

25.00 mm
25.40 mm
25.00 mm
Ok for Rebar Clear Spacing

N/A kN/m

No. of Bars

N/A mm2
N/A pcs

Spacing

N/A mm

Required Area of Dowel Reinforcement

Spacing Requirements as Specied by the Code


Minimum Clear Spacing, Smin
N/A mm
db
25.00 mm
4/3(Max. Aggregate)
25.40 mm
25mm
25.00 mm
Remarks

N/A

DETAILING

DIMENSIONS
Thickness of Wall, t
Depth of Embedment, D
Thickness of Footing, hc
Width of Footing, B

Transverse Reinforcements
Longitudinal Reniforcements
Dowels

REINFORCEMENTS
25.00
7
25.00
25.00

SIGN OF WALL FOOTING

plied with Concentric Loads, Lateral Loads & Moments

DESIGN CRITERIA
NSCP 2010

DESIGN REFERENCE

Type of Loads

Load

Dead Load, PDL

200.00

Live Load, PLL

180.00

Wind Load, PWL


Eathquake Load, PEQ
Total Pa

Type of Loads

0.00

280.00

528.00

420.00

Pu

420.00

0.00

528.00

0.00
380.00
Lateral Loads, H (kN/m)
Load Combination
I
II
III
IV

Load

Dead Load, HDL

0.00

Live Load, HLL

0.00

Wind Load, HWL

0.00

Eathquake Load, HEQ


Total Ha

0.00
0.00

Type of Loads

Concentric Loads, P (kN/m)


Load Combination
I
II
III
IV

0.00

0.00

Live Load, MLL

0.00

Wind Load, MWL

0.00

Eathquake Load, MEQ


Total Ma

0.00
0.00

0.00

0.00

Moments, M (kN-m/m)
Load Combination
I
II
III
IV

Load

Dead Load, MDL

0.00

0.00

Type of Concrete
Compressive Strength of Footing, fc'

0.00

0.00

Hu

0.00

Mu

0.00

0.00

Normal-Weight Concrete
28.00 Mpa

Compressive Strength of Wall, fc'


Yield Strength of Main Reinforcements
Allowable Soil Pressure, qa
Surcharge, q
Unit Weight of Concrete, c
Unit Weight of Soil, s

28.00
280.00
200.00
0.00
24.00
16.00

Strength Reduction Factors,


a. Tension-contolled Sections
b. Shear & Torsion
c. Bearing

0.90
0.75
0.65

Mpa
Mpa
kPa
kPa
kN/m3
kN/m3

0.00

0.85

=
=

0.85
0.0020

0.00

Modification Factor,

1.00

FLEXURAL REINFORCEMENTS

Spacing of Bars
No. of Long Bars

From the Actual Soil Pressure Diagram


Actual Moment @ Critical Section, Mu

350.00
7

108.30 kN-m

For the Transverse Reinforcements


Coeffiecient of Resistance, Ru
Required Steel Ratio, req
Minimum Steel Ratio Requirements
Approach
Minimum Steel Ratio, min
Remarks
Area of Steel @ Transverse Direction
Actual Spacing
Actual Clear Spacing
Provided Spacing
Spacing Requirements
Maximum Spacing, Smax
3hc
450 mm

0.79 Mpa
0.0029

Conservative
0.0020
Use req
0.0029
1,372.39
357.67
332.67
350.00

mm2
mm
mm
mm

450.00 mm
1,432.50 mm
450.00 mm

Remarks, Use S

350.00 mm

Minimum Clear Spacing, Smin


db
4/3(Max. Aggregate)
25mm
Remarks, Use S

25.40
25.00
25.40
25.00
350.00

Spacing, S
For the Longitudinal Reinforcements
Required No. of Longitudinal Bars
Spacing, S

350.00 mm
7.00 pcs
350.00 mm

Adequate
Adequate

Wall
Footing

DEVELOPMENT LENGTH

mm
mm
mm
mm
mm

Development for Tension (Transverse Bars)


Uncoated or Galvanized
Coating of Bars
Factors,
t
1.30
e
1.00
s
1.00
Checking of Factors
t e
Required t e
Cb
Distance from the nearest concrete surface
Half of Spacing, S

1.30
1.30
87.50 mm
87.50 mm
175.00 mm

Minimum Development Length (ld)

300.00 mm

Basic Development Length (ldb)


Development Length (ld)
Actual Development Length (ld)
Remarks

446.69 mm
437.11 mm
875.00 mm
Adequate

Development for Compression (Dowels)


At Wall
Minimum Basic Development Length (ldb)

200.00 mm

Basic Development Length (ldb)


(0.24fydb)/(fc')

317.49 mm
317.49 mm

0.043dbfy
Development Length (ld)
Remarks

301.00 mm
873.19 mm
Adequate

At Footing
Basic Development Length (ldb)

317.49 mm

(0.24fydb)/(fc')

317.49 mm

0.043dbfy
30.10 mm
Development Length (ld)
873.19 mm
Actual Development Length (ld)
352.50 mm
Inadequate: Increase hc or Requires Bending
Remarks
If Bending of Bars are Considered
Bend Diameter
Actual Splice
Maximum Length of Bend
Remarks

DETAILING

SIONS
300.00
1,217.50
477.50
2,200.00

mm
mm
mm
mm

CEMENTS
mm dia. @
mm dia. @
mm dia. @

350.00 mm
350.00 mm
900.00 mm

150.00 mm
465.32 mm
950.00 mm
Adequate

mm
pcs

Adequate
Adequate

CODE
NSCP 2001
NSCP 2010

Strength-Reduction Factors
Tension-controlled
Shear & Torsion
Bearing on Conrete
Sections
0.90
0.85
0.70
0.90
0.75
0.65

Conservative
More Conservative

Epoxy-Coated
Other Epoxy-coating
Uncoated or Galvanized

1.50
1.20
1.00

Modification Factors
Normal-Weight
Lightweight
Sand-lightweight
Concrete
Concrete
Concrete
1.00
0.75
0.85
1.00
0.75
0.85

GENERAL NOTES

1 Text in GREEN is the design input. This where you must type/input the values according to your design spe
2 Text in BLUE is the result of values you have typed/selected.
3 Text in BLACK is for general instructions.

es according to your design specifications