Ethernet
Switch
Upgrade Guide
R1.0
V2.09.10
Version
Internal Use On
ly
LEGAL INFORMATION
By accepting this certain document of ZTE CORPORAT ION you agree to the following terms. If you do
not agree to the following terms, please notice that you are not allowed to use this document.
Copyright 2014 ZT E CORPORAT ION. Any rights not expressly granted herein are reserved. This
document contains proprietar y information of ZTE CORPORAT ION. Any reproduction, transfer,
distribution, use or disclosure of this document or any por tion of this document, in any form by any
means, without the prior written consent of ZTE CORPORAT ION is prohibited.
and
are registered trademarks of ZTE CORPORAT ION. ZTEs company name, logo
and product names referenced herein are either trademarks or registered trademar ks of ZTE
CORPORAT ION. Other product and company names mentioned herein may be trademarks or trade
names of their respective ow ners. Without the prior written consent of ZTE CORP ORAT ION or the
third party owner thereof, anyones access to this document should not be construed as granting, by
implication, estopped or otherwise, any license or right to use any mar ks appearing in the document.
The design of this pr oduct complies with requirements of environmental protection and personal
security. This product shall be stored, used or discarded in accordance with product manual, relevant
contract or laws and regulations in relevant countr y (countries).
This document is provided as is and as available. Information contained in this document is subject
to continuous update without further notice due to improvement and update of ZT E CORPORAT IONs
products and technologies.
ZTE CORPORATION
Address:
NO. 55
Hi-tech Road South
ShenZhen
P.R.China
518057
Website:
Email:
TSM.Aftersales@zte.com.cn
Internal Use On
ly
Revision History
Product Version
V2.09.10
Document Version
R1.0
Serial Number
Author
Date
2013-1-11
Document Version
R1.0
Prepared by
Yang Zheng
Reviewed by
Approved by
Huang Zhiyan
II
Applicable to:
Internal Use On
ly
Proposal: Before reading this document, you had better have the following knowledge and skills.
SEQ
Reference material
1
2
3
Follow-up document: After reading this document, you may need the following information
SEQ
Reference material
Information
1
2
3
III
Internal Use On
ly
Description
Version Information
Upgrade Flow
Bootrom Upgrade
Version Rollback
upgrade
IV
Internal Use On
ly
TABLE OF CONTENTS
1
3
3.1
3.2
3.3
3.4
3.5
3.5.1
3.5.2
3.6
3.6.1
3.6.2
3.6.3
3.6.4
4
4.1
4.2
4.3
4.4
4.4.1
4.4.2
4.4.3
4.4.4
4.4.5
5
5.1
5.2
5.3
5.4
5.4.1
5.4.2
5.4.3
5.4.4
5.4.5
5.4.6
5.4.7
5.4.8
5.4.9
Internal Use On
ly
6
6.1
6.2
6.3
6.4
AppA
A.1
A.1.1
A.1.2
A.2
A.2.1
A.2.2
A.3
Usage Guideline for Common Terminal Software and FTP Software ........ 20
Terminal Software ............................................................................................... 20
HyperTerminal..................................................................................................... 20
SecureCRT ......................................................................................................... 20
FTP Tool.............................................................................................................. 21
3CDaemon .......................................................................................................... 21
WFTPD................................................................................................................ 22
Araxis merge ....................................................................................................... 23
VI
Internal Use On
ly
FIGURES
Figure 2-1 Version Upgrade Flow............................................................................................ 1
Figure 4-1 Bootrom Upgrade Flow .......................................................................................... 8
Figure 5-1 Software Version Upgrade Flow .......................................................................... 12
TABLES
Table 1-1 Product Model.......................................................................................................... 1
Table 3-1 Preparation Records before Upgrade ..................................................................... 2
Table 3-2 Checklist of System Running State......................................................................... 6
Table 4-1 Bootrom Upgrade Process ...................................................................................... 9
Table 5-1 Software Version Upgrade Process ...................................................................... 13
VII
Internal Use On
ly
Version Information
Tip:
This guide is applicable to engineers who are familiar with data products, have experiences
in data product upgrade, and pass ZTE Data Products Certificate Test-Level I or above.
ZXR10 5960& 5900E series switches include 2 product series, among which 5900E
series switches contain multiple product models, as shown in Table 1-1.
Table 1-1
Product Model
Product Series
Product Model
5900E series
5960 series
The soft ware package for ZXR10 5960&5900E Series switches contains many files.
Refer to for the list of the files.
Table 1-1
File Name
(Including
Path)
File Type
\5960\
\59E\xls108
Note:
The V2.9.10 version supports 5900E xls108 sub-card only. The 5900E device running 8270
sub-card cannot be upgraded to this version. During the version upgrade on site, it may need
to upgrade the bootrom. For detailed information, refer to the release notes.
Internal Use On
ly
Upgrade Flow
Figure 2-1 depicts the upgrade flow of ZXR10 5960&5900E Series switches.
Figure 2-1
Start
Preparation before
upgrade
Whether
bootrom needs
to be
upgraded?
Upgrade Bootrom
Version rollback
Upgrade software
version
Upgrade
succeeds?
Y
End
1.
2.
Bootrom Upgrade
During the preparation, make clear whether Boot rom upgrade is needed in the
upgrade. If yes, refer to 4 BOOTROM UPGRADE to perform the upgrade.
This process lasts about 5-10 minutes.
3.
Internal Use On
ly
Version Rollback
If the version upgrade fails, the version rollback should be performed. Specific
failure situation requires specific rollback procedure. For detailed method, refer to 6
VERSION ROLLBACK.
The rollback lasts about 30 minutes.
Internal Use On
ly
3.1
Table 3-1
S/N
3.2
Completed
or Not
Read
version
accompanying documents
Prepare
hardware
Set
up
environment
Back
up
information
Check services
software
Record of Preparation
and
upgrade
configuration
2.
Internal Use On
ly
3.3
2.
3.4
Hardware preparation
If possible, prepare spare parts for switches at key nodes and tools necessary
for the replacement;
Prepare serial console cables and net work cables needed; and check whether
they are usable.
Software preparation
Prepare FTP/ TFTP tool software nec essary for upgrade, and check if t hey are
usable;
Data Bits: 8
Parity: None
Stop Bits: 1
Internal Use On
ly
After the configuration, make s ure that access to the device is available via the
serial port. Next, enable aut omatic logging function for the terminal software.
For detailed setting method, refer to A.1 Terminal Software.
2.
3.
3.5
Backing up Data
3.5.1
Check current configuration of the devic e and save t he dis played configuration to
the background server.
ZXR10#show running-config
2.
Save the current configuration and make sure that it is saved properly.
ZXR10#write
Building configuration...
..[OK]
ZXR10#cd cfg
ZXR10#dir
Directory of flash:/cfg
attribute
size
date
time
name
drwx
2048
Jan-11-2013
14:11:27
drwx
2048
Jan-01-2000
00:00:24
..
Internal Use On
ly
----
3233
Jan-11-2013
14:11:27
startrun.dat
-rw-
7177
Jul-03-2012
10:21:00
lacpv6.dat
-rw-
8185
Jul-03-2012
08:44:20
mc234.dat
3.
bytes free)
On 5900E:
ZXR10#copy flash: /cfg/startrun.dat ftp: //169.1.3.12/startrun.dat@ztezte:ztezte
On 5960:
ZXR10#copy root flash/cfg/startrun.dat ftp: //169.1.3.12/startrun.dat@ztezte:ztezte
On 5900E:
ZXR10#copy flash: /cfg/startrun.dat ftp: mng //169.1.3.12/startrun.dat@ztezte:ztezte
On 5960:
ZXR10#copy root flash/cfg/startrun.dat ftp: mng //169.1.3.12/startrun.dat@ztezte:ztezte
Note:
1. The version that the 5960 device can start to run is V2.09.10.
2. In this document, the 5900E device is upgraded from V2.8.23.C to V2.09.10. Note that the
copy command is different from that on the 5960 device.
3.5.2
ZXR10#dir img
Directory of flash:/img
attribute
size
date
time
name
drwx
2048
Sep-10-2012
16:10:09
drwx
2048
Jan-01-2000
00:00:24
..
-rwx
15990287
Jul-03-2012
15:42:51
16p01.zar
-rwx
16423968
Jun-14-2001
02:16:46
B2.zar
-rwx
16279272
Mar-16-2012
09:25:03
zxr10.zar04
-rwx
16298516
Apr-26-2012
17:30:03
zxr10.zar07
-rw-
17216928
Nov-12-2012
15:39:42
B8.dat
-rwx
16939008
Dec-10-2012
09:36:01
B10.zar
-rwx
16004107
Dec-10-2012
10:54:58
P02.zar
10
-rwx
16003448
Jan-11-2013
13:56:16
zxr10.zar
11
-rwx
642432
2.
Nov-21-2012
10:24:30
Internal Use On
ly
bootrom.bin
bytes free)
On 5900E:
ZXR10#copy flash: /img/zxr10.zar ftp: //169.1.3.12/zxr10.zar@ztezte:ztezte
On 5960:
ZXR10#copy root flash/img/zxr10.zar ftp: //169.1.3.12/zxr10.zar@ztezte:ztezte
On 5900E:
ZXR10#copy flash: /img/zxr10.zar ftp: mng //169.1.3.12/zxr10.zar@ztezte:ztezte
On 5960:
ZXR10#copy root flash/img/zxr10.zar ftp: mng //169.1.3.12/zxr10.zar@ztezte:ztezte
3.6
3.6.1
RUN indicat or
Off The main board is faulty.
Flash The main board is working normally.
2.
PWR indicator
Constantly on The system power is working normally.
Off The system power is faulty.
3.
Internal Use On
ly
LINK/ACT indicator
Flash There are packets being received or sent on the interface.
On A link has been established on this interface.
Off No interconnection is established between this interface and another interfac e.
4.
FDX/ COL
On The interface link is in full duplex mode.
Off The interface link is in half duplex mode.
Flash There is a receiving/sending conflict on this interface.
3.6.2
Table 3-2
Command
show version
show bootrom
Display
the
current
configuration file
show running-config
show process
Display
information
show ip route
routing
Display
statistics
show interface
port
Display
layer-3
information
traffic
port
show mac
Display
ARP
information
show arp
dir data
Remark
Item
Command
Internal Use On
ly
Remark
file folder
3.6.3
Display
PIM-SM
adjacency information
show ip mroute
show clock
Checking Services
Check running status of services on the device. Items to be checked can be adjusted
according to specific services at the sites where the devices are to be upgraded.
The customers should assist in inspecting services and confirm the results.
3.6.4
ZXR10#dir
Directory of flash:/
attribute
size
date
time
name
drwx
2048
Jan-01-2000
00:00:24
drwx
Jan-01-2000
00:00:26
..
----
131072
Jan-01-2000
00:00:24
capture
-rwx
714664
Mar-23-2012
16:09:47
zdbagent
-rwx
309900
Mar-26-2012
10:54:00
ztam
drwx
2048
Sep-10-2012
16:10:09
img
drwx
2048
Jan-04-2013
09:14:38
data
----
393152
Jan-01-2000
00:00:33
record
drwx
2048
Jan-11-2013
14:11:27
cfg
10
drwx
2048
Jan-01-2000
00:00:03
lost+found
10
2.
Internal Use On
ly
ZXR10#cd cfg
ZXR10#dir
Directory of flash:/cfg
attribute
size
date
time
name
drwx
2048
Jan-11-2013
14:11:27
drwx
2048
Jan-01-2000
00:00:24
..
----
3233
Jan-11-2013
14:11:27
startrun.dat
-rw-
7177
Jul-03-2012
10:21:00
lacpv6.dat
-rw-
8185
Jul-03-2012
08:44:20
mc234.dat
11
Internal Use On
ly
Bootrom Upgrade
Please skip this chapter if the boot rom doesnt need to be upgraded.
This chapter covers precautions, upgrade procedures, emergency handling and bootrom
burning proc edures.
4.1
Precautions
ZXR10 5960&5900E switches support live upgrade of the bootrom. In the upgrade, the
following items should be noted:
1.
Never upgrade the boot rom online when CP U utilizations are high;
2.
Never power off the system during the live upgrade of the boot rom, otherwise the
system will be unable to start.
3.
The 108CP U sub-cards of 5960 and 5900E are both set with bootrom
master/slave zones.
ii.
iii.
If the bootrom update fails, do not restart the device directly. Try to upgrade the
bootrom a few more times.
iv.
After the bootrom upgrade, if the device fails to load the boot file upon restart,
then, when the timer expires, the system will switch back to the current zone to
start, so as to make sure that the devic e can restore basic operation.
12
4.2
Internal Use On
ly
Upgrade Flow
Figure 4-1
Update bootrom
Verify upgrade
End
4.3
Table 4-1
S/N
4.4
Delete
Files
Remaining
Verify Upgrade
Completed
or Not
Record of Implementation
Boot
Upgrade Procedure
Detailed upgrade steps are as follows.
13
4.4.1
Internal Use On
ly
size
date
time
name
drwx
2048
Sep-10-2012
16:10:09
drwx
2048
Jan-01-2000
00:00:24
..
-rwx
15990287
Jul-03-2012
15:42:51
16p01.zar
-rwx
16423968
Jun-14-2001
02:16:46
B2.zar
-rwx
16279272
Mar-16-2012
09:25:03
zxr10.zar04
-rwx
16298516
Apr-26-2012
17:30:03
zxr10.zar07
-rw-
17216928
Nov-12-2012
15:39:42
B8.dat
-rwx
16939008
Dec-10-2012
09:36:01
B10.zar
-rwx
16004107
Dec-10-2012
10:54:58
P02.zar
10
-rwx
16003448
Jan-11-2013
13:56:16
zxr10.zar
11
-rwx
642432
Nov-21-2012
10:24:30
bootrom.bin
4.4.2
On 5900E:
ZXR10#copy ftp: //169.1.3.12/bootrom.bin@ztezte:ztezte flash: /img/bootrom.bin
On 5960:
ZXR10#copy ftp: //169.1.3.12/bootrom.bin@ztezte:ztezte root flash/img/bootrom.bin
On 5900E:
14
Internal Use On
ly
size
date
time
name
drwx
2048
Jan-11-2013
14:38:08
drwx
2048
Jan-01-2000
00:00:24
..
-rw-
650144
Jan-11-2013
14:38:10
bootrom.bin
-rwx
15990287
Jul-03-2012
15:42:51
16p01.zar
-rwx
16423968
Jun-14-2001
02:16:46
B2.zar
-rwx
16279272
Mar-16-2012
09:25:03
zxr10.zar04
-rwx
16298516
Apr-26-2012
17:30:03
zxr10.zar07
-rw-
17216928
Nov-12-2012
15:39:42
B8.dat
-rwx
16939008
Dec-10-2012
09:36:01
B10.zar
10
-rwx
16004107
Dec-10-2012
10:54:58
P02.zar
11
-rwx
16003448
Jan-11-2013
13:56:16
zxr10.zar
Note:
File name of the boot saved to the FLASH must be correct and identical to that in the
software package.
After copying, execute the dir img command to check whet her the boot file size is
consistent with that on the FTP server.
4.4.3
Upgrading bootrom
Record information of the old boot:
ZXR10#sho bootrom
Common Zone Version : V1.01
Creation Date
: 2011/8/5
: 2012/1/15
: V3.14
: 2012/1/15
The device boot from slave boot zone this time. ---The currently used zone is the slave
zone.
15
1.
Internal Use On
ly
ZXR10#olleh
zxr10(config-increte)#
2.
ZXR10(config-increte)#bootrom update
If t he update succeeds, the system will give out a message to indicate that the update is
successful.
Tip:
If it shows that the update fails, please delete the corresponding boot file under the img
directory and recopy a new one to perform the update again. If the upgrade still fails after
several times of attempts, replace bootrom chip of corresponding card manually.
4.4.4
3.
4.
Verifying Upgrade
After updating the boot, check whet her the boot has been updated:
ZXR10#show bootrom
Common Zone Version : V1.01
Creation Date
: 2011/8/5
Master Zone Version : V3.33 -----the zone where the boot should be updated
Creation Date
: 2013/1/11
: V3.14
: 2012/1/12
slave zone
Note: The command bootrom update is used to update the boot in the idle zone. In this
example, the currently used zone is slave while the idle zone is master. Hence, it is the
master zone that is updated.
4.4.5
16
Internal Use On
ly
ZXR10(config-increte)#bootrom update
After that, check whether the boot of master and slave zones has been updated successfu
lly:
ZXR10#show bootrom
Common Zone Version : V1.01
Creation Date
: 2011/8/5
: 2013/1/11
: V3.33
: 2013/1/11
17
Internal Use On
ly
5.1
5.2
Precautions
1.
Set the aut o-logging function of the t erminal software before the upgrade for later
analysis of the reason behind the unexpected upgrade failure;
2.
During the process of writing the version int o the FLASH, never restart the device or
power it off, otherwise the FLAS H may be damaged;
3.
During the process of writing the version into the FLASH, CP U utilization will rise, so
it is forbidden to implement other operations on the de vice.
4.
5.
Upgrade Flow
Figure 5-1 depicts the software version upgrade flow.
18
Figure 5-1
Internal Use On
ly
Reboot switch
Check configuration
information
Verify upgrade
End
5.3
Table 5-1
S/N
1
Completed
or Not
Record of Implementation
19
Step
S/N
5.4
Restart Switch
Check
Device
Check
New
Information
Check
Information
Verify Upgrade
Boot
Completed
or Not
Status
Internal Use On
ly
Record of Implementation
of
Version
Configuration
Upgrade Procedure
Detailed upgrade steps are as follows.
5.4.1
Delet e the old version file if the FLASH cannot accommodate two versions:
ZXR10#cd img
ZXR10#delete zxr10.zar
5.4.2
Note:
The name of the target version file saved to the FLASH must be zxr10.zar.
On 5900E:
ZXR10#copy ftp: //169.1.3.12/zxr10.zar@ztezte:ztezte flash: /img/zxr10.zar
On 5960:
ZXR10#copy ftp: //169.1.3.12/zxr10.zar@ztezte:ztezte root flash:/img/zxr10.zar
On 5900E:
ZXR10#copy ftp: mng //169.1.3.12/zxr10.zar@ztezte:ztezte flash: /img/zxr10.zar
20
Internal Use On
ly
On 5960:
ZXR10#copy ftp: mng //169.1.3.12/zxr10.zar@ztezte:ztezte root flash/img/zxr10.zar
After downloading, execut e command dir img to check whet her t he version file size is
consistent with that on FTP server.
ZXR10#dir
Directory of flash:/img
attribute
size
date
time
name
drwx
2048
Jan-11-2013
14:43:32
drwx
2048
Jan-01-2000
00:00:24
..
-rw-
16950384
Jan-11-2013
14:44:25
zxr10.zar
-rwx
16003448
Jan-11-2013
13:56:16
backup.zar
-rw-
650144
Jan-11-2013
14:38:10
bootrom.bin
-rwx
15990287
Jul-03-2012
15:42:51
16p01.zar
-rwx
16423968
Jun-14-2001
02:16:46
B2.zar
-rwx
16279272
Mar-16-2012
09:25:03
zxr10.zar04
-rwx
16298516
Apr-26-2012
17:30:03
zxr10.zar07
10
-rw-
17216928
Nov-12-2012
15:39:42
B8.dat
11
-rwx
16939008
Dec-10-2012
09:36:01
B10.zar
12
-rwx
16004107
Dec-10-2012
10:54:58
P02.zar
5.4.3
If the boot mode is the boot via network, you can execute relevant command to change it
to the local boot, and save the configuration:
ZXR10(config)#nvram imgfile-location local
ZXR10(config)#exit
ZXR10#write
21
5.4.4
Internal Use On
ly
Configure the backup version as the file backup.zar in the IMG directory of the flash:
2.
ZXR10#show nvram-info
nvram boot-username ztezte
nvram boot-password ztezte
nvram boot-server 169.1.3.12
nvram default-gateway 169.1.3.12
nvram mng-ip-address 169.1.3.124 255.255.255.0
nvram imgfile-location local flash img/zxr10.zar
nvram backup-imgfile img/backup.zar
When the device starts, if there is no file zxr10.zar, it will start from the backup file
backup.zar.
5.4.5
Note:
If the device cannot start normally, and the reason could not be spotted within 20 minutes,
this upgrade is regarded as failed. Refer to emergency handling to roll back to the old
version.
5.4.6
PhyMem
Buffer
Memory
22
MP(M)
28%
26%
48%
512
0%
Internal Use On
ly
62.068%
14:53:19 01/11/201
5.4.7
9 2013, 16:12:57
V1.2
System temperature(Celsius):50
5.4.8
5.4.9
Verifying Upgrade
Items to be verified after the upgrade should be substantially identical to that before the
upgrade, which mainly covers the following parts:
23
1.
Internal Use On
ly
2.
3.
Check services
Check running state of services on the device. Items to be checked can be adjusted
according to specific services at the sites where the devices are to be upgraded.
The customers should assist in inspecting services and confirm the results.
Note:
In case the services are abnormal and are caused by the device itself, but the causes could not
be located within 20 minutes, the upgrade is regarded failed. Refer to Emergency Handling
to roll back to the old version.
24
Internal Use On
ly
Version Rollback
This chapter describes specific rollback steps for diverse situations.
6.1
Rollback Application
If the upgrade fails, you s hould perform the version rollback. You s hould take different
rollback steps for different failures.
Roll back to the old version if the upgrade from V2823 C to V2.09.10 fails.
Roll back to the old boot rom version of V2823C. For details, refer to 6.4.
Note:
If the rollback fails, or an accident occurs, please contact instructors from Customer Service
Department.
6.2
2.
25
Internal Use On
ly
7 2013, 09:00:43
[boot]: c
'.' = clear field;
'^' = quit
: 169.1.3.124
address
Netmask
: 255.255.255.0
Server IP
: 169.1.3.12
: 169.1.3.12
server
Gateway IP
address of port number
FTP User
: ztezte
FTP Password
Bootfile
: zxr10.zar
Enable Password
[boot]:
3.
[boot]: b
Boot Location [0:Net,1:Flash] : 0
Client IP
: 169.1.3.124
Netmask
: 255.255.255.0
Server IP
: 169.1.3.12
Gateway IP
: 169.1.3.12
FTP User
: ztezte
FTP Password
Bootfile
: zxr10.zar
Enable Password
MAC Address
: 00.00.00.00.11.00
4.
Verify rollback
After restarting the s witch, check whet her t he version number is the old version
number and whether the servic es are normal.
5.
26
Internal Use On
ly
After making sure that the device and services work normally, delete the version
with a problem during the upgrade, and writ e the normal version file to the directory
img of flash.
On 5900E:
ZXR10#copy ftp: //169.1.3.12/zxr10.zar@ztezte:ztezte flash: /img/ zxr10.zar
On 5960:
ZXR10#copy ftp: //169.1.3.12/zxr10.zar@ztezte:ztezte root flash/img/ zxr10.zar
On 5900E:
ZXR10#copy ftp: mng //169.1.3.12/zxr10.zar@ztezte:ztezte flash: /img/zxr10.zar
On 5960:
ZXR10#copy ftp: mng //169.1.3.12/zxr10.zar@ztezte:ztezte root flash/img/zxr10.zar
6.
6.3
Delet e the new version file that is copied to the img directory of FLASH during the
upgrade, and modify the name of the old version file to zxr10.zar.
ZXR10#delete zxr10.zar
ZXR10#rename old.zar zxr10.zar
Note:
Since the FLASH has no sufficient space and the old version file has been deleted before
upgrade, it is necessary to recopy the old version file to FLASH. For detailed steps, see 5.4.2.
2.
3.
27
Internal Use On
ly
After restarting the s witch, check whet her t he version number is the old version
number and whether the servic es are normal.
6.4
V2.8.23C
Being
After the onsite devices are upgraded from V2.8.23C to V2.09.10, if the services become
abnormal, it is necessary to roll back the software version and bootrom version.
In this scenario, the rollback procedures are slightly different from the upgrade
procedures. To go back to the V2.8. 23C, first roll back the bootrom version and then the
software version. Follow the steps below for rollback.
1.
Delet e the new version file copied to the IMG directory of the flash during the
upgrade, and rename the old version file as zxr10.zar.
2.
Copy the boot file of the old version file to the flash, degrade the bootrom of the
devic e. For how to degrade the bootrom, refer to 4 Bootrom Upgrade.
3.
4.
Restart the old version to confirm whether the device is started normally.
5.
Note:
To ensure the stability of the two systems, use the matched bootrom versions during the
inter-version upgrade or degrade.
28
Internal Use On
ly
2.
3.
Q: When an accident occurs, what information needs being collected for further
analysis?
A: Printing information on the serial port, alarming information on the device and
basic information on the device when the services become abnormal. Furthermore,
if the device fails to start normally, note which status the indicators on the card are
in.
4.
Q: In the process of V 2.8.23B being upgraded into V 2.8.23C, after the Boot rom
online upgrade is finished, you can find the version ID doesnt change while the
creation time changes by executing the show bootrom command.
A: This problem is the data reading problem in the bootrom updat e of the V2.8.23B.
It has no influence on the bootrom version update. You can check the bootrom state
after the device is restarted to see whether the bootrom updat e is successful.
29
Internal Use On
ly
A.1
Common terminal soft ware includes HyperTerminal and Sec ureCRT. Here, we will
introduce how to set the two types of software. Items to be set contain:
A.1.1
Port attribute
HyperTerminal
The HyperTerminal is usually used for the serial port connection. The following describes
the setting for it.
A.1.2
1.
2.
Type the name of the connection in <Name> of [Connection Description] dialog box,
and click <OK>. The [Connect To] dialog box will be presented.
3.
Select the COM port in <Connect using> option of [Connect To] dialog box for the
host to connect to the device and click the OK. [COM Properties] dialog box pops
up.
4.
Click <Restore Defaults (R)> in <COM Properties> dialog box, modify <Bits per
second (B )> as required, click <OK> to finish the setting and ent er HyperTerminal
main interface.
5.
If it is nec essary to record operation logs, click [Trans fer (T)] menu and select [Text
Capt ure (C)]. Then the [Text Capture] dialog box pops up. Select log file in the
dialog box and click <Start> to finish the setting.
SecureCRT
SecureCRT is commonly used for the serial port connection and telnet connection.
1.
Run the S ecureCRT software. The SecureCRT main interface and [connect] dialog
box will pop up.
30
Internal Use On
ly
If [connect] dialog box is closed, you can click the first button <Connect> on the tool
bar of the main interface or select [Connect] in [File] menu to open it.
2.
Click the third button <New S ession> on the tool bar of [ Connect] dialog box to
establish a new session. [Session Options] dialog box will pop up.
3.
ii.
Click <OK> to finish the setting and enter Sec ureCRT main interface.
4.
A.2
If it is necessary to record operation logs, click [File] menu, and select [Log Session].
And the corresponding dialog box pops up. Select the log file in the dialog box and
click <Save (S)> to finish the setting.
FTP Tool
Common FTP server tools include 3CDaemon and WFTPD. The following will introduce
how to set the two types of soft ware. Items to be set contain:
FTP username/password
Directory on the server used for storing the version file or configuration file
31
Internal Use On
ly
A.2.1
3CDaemon
1.
2.
Open [FTP Server] module on the left, click [Configure FTP Server]. And
[3CDaemon Configuration] dialog b ox pops up. Then perform the following
operations:
i.
ii.
iii.
In the input box below, type directory, e.g. IMG directory of Disk D used for
saving version file or configuration file, or click the button on the right of the
input box to select the directory;
iv.
Select Login, Download and Upload in the list below < This user can:>;
v.
AppFigure A-1
3CDaemon Window
32
A.2.2
Internal Use On
ly
WFTPD
1.
2.
3.
i.
Click <New Us er...> to create a user, such as target, and set a password.
ii.
iii.
Type in a directory in the <Home Directory> box, such as, the IMG directory on
Disk D to save version file and configuration file.
AppFigure A-2
A.3
WFTP D Window
Araxis merge
Araxis merge is a file comparison tool. During the version upgrade, it is commonly used
to compare configurations after and before upgrade.
The Araxis merge is very easy to use.
1.
Run the Araxis merge. Then the main interface pops up. We can see the main
interface is divided into two parts: left and right. Each part has an input box,
displaying Y ou can type a filename here.
33
2.
Internal Use On
ly
Click the button <...> on the right of each input box respectively, and select two files
that needs to be compared. The selected files are displayed on the two sides of the
main interface, and the different places are clearly marked.
AppFigure A-3
34