Vous êtes sur la page 1sur 42

CONTENTS

iPASOLINK EX

CHAPTER I INSTALLATION

CONTENTS

OVERVIEW ..........................................................................................................................................1-1

CONTENTS AND REQUIRED PARTS ...............................................................................................2-1

UNPACKING IPASOLINK EX .............................................................................................................3-1

MOUNTINIG IPASOLINK EX ..............................................................................................................4-1

CONNECTING AND FORMING CABLES ..........................................................................................5-1

GROUNDING THE FRAME .................................................................................................................6-1

START UP / SHUT DOWN ..................................................................................................................7-1

ORIENTING ANTENNA.......................................................................................................................8-1

Installation

NWD-153831-01E

ii

CONTENTS

This page is intentionally left blank

NWD-153831-01E

Installation

OVERVIEW

1-1

OVERVIEW

The standard installation is summarized in this section. Following shows the installation work flow.

Unpacking iPASOLINK EX
See Section3
Mounting iPASOLINK EX
See Section4
Connecting and Forming Cables
See Section5
Grounding the Frames
See Section6

Start up iPASOLINK EX
See Section7
WebLCT should be prepared here.
Refer to Chapter II Operation.

Antenna Orientation
See Section8

Figure 1-1 Installation Flow

Installation

NWD-153831-01E

1-2

OVERVIEW

This page is intentionally left blank

NWD-153831-01E

Installation

CONTENTS AND REQUIRED PARTS

2-1

CONTENTS AND REQUIRED PARTS

Following shows the list of iPASOLINK EX installation. Confirm them before starting the installation.

2.1 Contents Parts List

No.

Description

Drawing No.

TRP-80G1000MB-1A

Figure 2-1

Power cable

Figure 2-2

Figure 2-1 iPASOLINK EX

Figure 2-2 Power Cable

Installation

NWD-153831-01E

CONTENTS AND REQUIRED PARTS

2-2

This page is intentionally left blank

NWD-153831-01E

Installation

CONTENTS AND REQUIRED PARTS

2-3

2.2 Required parts List

No.

Description

Drawing No.

Ethernet Cable with Waterproofing Cap (ELE type)

Figure 2-3

Ethernet Cable with Waterproofing Cap (Opt type)

Figure 2-4

Antenna (with Pole Mounting Bracket)

Figure 2-5, 2-6, 2-7


(The details are referred to the installation
manual which is attached the antenna.)

Figure 2-3 EthernetCablewithWaterproofingCap(ELEtype)

Figure 2-4 EthernetCablewithWaterproofingCap(OPTtype)

Figure 2-5 Antenna(example)

Installation

NWD-153831-01E

2-4

CONTENTS AND REQUIRED PATRS

Figure 2-6 PoleMountBracket(example)

Figure 2-7 AntennaBracket(example)

NWD-153831-01E

Installation

UNPACKING iPASOLINK EX

3-1

UNPACKING IPASOLINK EX

The unpacking procedures for the iPASOLINK EX is shown in following chart.


Note When conveying the iPASOLINK EX to another place, the original packing should be used to avoid
damage.

1 Open the top cover of the packing box.

Care Mark

2 Take out Power Cable and the iPASOLINK EX cushioning materials (pads) and poly sheet.

Power Cable
Top PAD

iPASOLINK EX

Poly Sheet

Bottom pad B

Bottom pad A

Inner Packing BOX

3 Take out the iPASOLINK EX from the poly sheet.


4 Inspect the iPASOLINK EX

Installation

NWD-153831-01E

3-2

UNPACKING iPASOLINK EX

This page is intentionally left blank

NWD-153831-01E

Installation

MOUNTING iPASOLINK EX

4-1

MOUNTINIG IPASOLINK EX

This section provides the installation procedures to mount iPASOLINK EX an d


A n t e n n a onto a Pole.

Tools required for the installation are listed below.

Table 4-1 Tools

TOOLS

Wrench or Monkey Wrench

Screwdriver

Torque Wrench

4.1 For Placing Equipment

NOTICE

1.

iPASOLINK EX (equipment) generates non-ionizing radiation. Installing


the equipment indoors may affect, which needs to take the adequate
measures, if occurs.

2. The equipment should be installed in the appropriate site. Do not install it


on a slant or unstable spot. Improper installation raise the temperature
inside the equipment, which may damage the equipment.

3. Places where the iPASOLINK EX is/are installed should be restricted to a


Telecommunication Center or equivalent.

Accessing to the equipment is only by the SERVICE PERSONNEL or


by USERS who are well trained with enough skills and knowledge
regarding these restrictions, precautions and installation sites.

Accessing must be protected using a tool, locks, keys, and/or other


means of security, which should be managed by the authority who is
responsible for the installed site.

The other end of the Frame Ground (FG) should be connected to the
station earth point. For details, refer to 6. GROUNDING AND FORMING
CABLE section

Installation

NWD-153831-01E

MOUNTING iPASOLINK EX

4-2

4.2 Antenna Direct Mounting

4.2.1 Installation of Antenna and Adapter

Note: The details are referred to the installation manual which is attached the antenna.

4.2.2 Installation of iPASOLINK EX onto the Mounting Brackets.


Fix the iPASOLINK EX to the bracket by tightening the M6 screws which are equipped
iPASOLINK EX.
Note:The tightening torque of M6 screws is 4.0Nm 10
1 Install the iPASOLINK EX Horizontal

Figure 4-1 Mount iPASOLINK EX(Horizontal)

NWD-153831-01E

Installation

MOUNTING iPASOLINK EX

4-3

2 Install the iPASOLINK EX Vertical type

Figure 4-2 Mount iPASOLINK EX(Vertical)

Installation

NWD-153831-01E

MOUNTING iPASOLINK EX

4-4

This page is intentionally left blank

NWD-153831-01E

Installation

CONNECTING AND FORMING CABLES

5-1

CONNECTING AND FORMING CABLES

5.1 Overview

This section provides the descriptions for connecting traffic cables, power cable and
frame ground cable.

Following shows the summary of the cable installation:

1. Connect the Ground Cable to FG Terminal on iPASOLINK EX.

NOTE: Tightening torque is 13 2 kgcm

2. Connect Power Cable


NOTE: If you use the PoE, connection Power Cables are not required.

3. Connect Ethernet Cables for the use of power supply and communication.

(1)

Connect Ethernet Cable for power supply and communication to


P1(PoE)Port on iPASOLINK EX and a connection port on a power
injector.

NOTE: Confirm that the power injector is off. If it is powered on,


connecting the Ethernet cable to P1(PoE) port immediately
turns on the iPASOLINK EX.

NOTE: When using -48V if you do not need. If you want to use as the
P1 Port a Communication Port, Please connect the P1 Port.

4. Connect LAN Cable for WebLCT.

To operate WebLCT, connect your PC (web browser must be installed) and


LCT port on iPASOLINK EX.

NOTE: Please connect when use NMS/Web LCT.

Installation

NWD-153831-01E

CONNECTING AND FORMING CABLES

5-2

5.2 Connecting Terminals

5.2.1 iPASOLINK EX

iPASOLINK EX has following terminals.

4 2

1 3

Figure 5-1 Terminals on iPASOLINK EX

PORTS

No.
INDICATION

PURPOSE

FG

Terminal for Frame Ground (dia. 5 mm)

RX LEV MON

DCN

Terminal for Monitoring Receiving Signal


L
l
Terminal for WebLCT or NMS Connection

P4

Terminal for GbE (LC)

P2/P3

P2/ Terminal for GbE (RJ-45)


P3/ Terminal for GbE (LC)

P1(PoE)

Terminal for GbE/PoE (RJ-45)

DC-48V

Terminal for power supply

NWD-153831-01E

Installation

CONNECTING AND FORMING CABLES

5-3

5.3 Frame Ground Cable

Following shows the location of Frame Ground (FG) terminal.

FGterminal(M5

Figure 5-2 Location of FG Terminal

Installation

NWD-153831-01E

CONNECTING AND FORMING CABLES

5-4

5.4 Power Cable


Power cable to connect with iPASOLINK EX should wear a waterproofing cap.
Following shows the connecting method of Power cable with a waterproofing cap.

1. Uncover the protected port.

Waterproofing cap can be off by turning it counterclockwise

The removed cap should be protected by self-fusing tapes in order to


prevent the cap from getting water inside.

Insert the plug of Power Cable to the iPASOLINX EX and tighten the
Connector to the iPASOLINK EX with engage connector nut only using
fingers.

NWD-153831-01E

Installation

CONNECTING AND FORMING CABLES

5-5

Wrapping connector and cable by Self-Fusing tape for protection.

Installation

NWD-153831-01E

CONNECTING AND FORMING CABLES

5-6

5.5 Ethernet Cables

5.5.1 Connecting Ports


1. PoE Port Connection
To iPASOLINK EX, the power is supplied by a power injector using Ethernet cable.
Before connecting Ethernet cables, ensure that the power injector is off. Leaving the
power injector on in the installation allows iPASOLINK EX to start up immediately
after the connection of Ethernet cable to P1 terminal.

If the power injector is left on, iPASOLINK EX starts up immediately after


connecting the Ethernet Cable and P1 Port.

PoEPort
(Port1)

2. GbE/FE Port or Opt Connection

GbE/FEPort

OptPort

DCNPort

NWD-153831-01E

Installation

CONNECTING AND FORMING CABLES

5-7

5.5.2 Connect Ethernet Cables

Each Ethernet cable to connect with iPASOLINK EX should wear a waterproofing


cap. Following shows the connecting method of Ethernet cable with a waterproofing
cap.

1. Uncover the protected port.

Waterproofing cap can be off by turning it counterclockwise.

Figure 5-3 Remove Waterproofing Cap

The removed cap(s) should be protected by self-fusing tapes in order to


prevent the cap from getting water inside.

CAP (REAR)
CAP (FRONT)

Fully wrap to cover


inner cap completely.

Figure 5-4 Wrap Self-Fusing Tape around Removed Cap

Installation

NWD-153831-01E

CONNECTING AND FORMING CABLES

5-8

2. Insert the plug of Ethernet Cable with waterproofing cap.

Figure 5-5 Connect Ethernet Cable

3. Slide the waterproofing cap toward the port fully.

WATERPROOFING CAP

Figure 5-6 Place Waterproofing Cap

NWD-153831-01E

Installation

CONNECTING AND FORMING CABLES

5-9

4. Turn the waterproofing cap clockwise to lock the cap.

UNLOCKED

LOCKED

Figure 5-7 Lock Waterproofing Cap

Ensure that the locked mark is placed on top.

5. Using the self-fusing tape, secure the removed port cap onto the
waterproofing cap of the Ethernet Cable.

Secure removed port cap on


waterproofing cap of Ethernet
Cable using Self-Fusing tape.

Figure 5-8 Secure Waterproofing Cap Removed from Port


This step ends the procedure.

Installation

NWD-153831-01E

CONNECTING AND FORMING CABLES

5-10

5.5.3 Disconnect Ethernet Cables

1. Remove the bound cap away from the cables waterproofing cap.

Remove the self-fusing tape using a cutter knife or equivalent.

Remove self-fusing tape.

Figure 5-9 Waterproofing Cap of Port Secured by Self-Fusing Tape

Remove the self-fusing tape protecting the inner cap as well.

Remove self-fusing tape.

Figure 5-10 Port Cap Protected by Self-Fusing Tape

This cap is used to protect the vacant port after disconnecting the Ethernet
Cable (in Step 3.)

NWD-153831-01E

Installation

CONNECTING AND FORMING CABLES

5-11

2. Unlock the Waterproofing Cap by turning it counterclockwise, and release it


from the port.

LOCKED

UNLOCKED

Figure 5-11 Unlock Waterproofing Cap

3. Ensure to attach the waterproofing cap after disconnect the Ethernet Cable.

Figure 5-12 Attach Waterproofing Cap

This step ends the procedure.

Installation

NWD-153831-01E

CONNECTING AND FORMING CABLES

5-12

5.6 Pin Assignment of Connectors

Following shows the pin assignment of connectors used by iPASOLINK EX.

5.6.1 Ethernet Port (PoE PD)

Indication:

P1/DCIN

Connector Type:

RJ-45

Table5-1 Pin Assignment of P1 Port

RJ-45

1
2
3
4
5
6
7
8

PIN No.

PoE+(PD) ASSIGNMENT

Positive VPD, Negative VPD

Positive VPD, Negative VPD

Positive VPD, Negative VPD

Positive VPD, Negative VPD

Positive VPD, Negative VPD

Positive VPD, Negative VPD

Positive VPD, Negative VPD

Positive VPD, Negative VPD

NWD-153831-01E

Installation

CONNECTING AND FORMING CABLES

5-13

5.6.2 Ethernet Port (GbE)

Indication:

P2

Connector Type:

RJ-45

Table5-2 Pin Assignment of P2 Port

RJ-45

1
2
3
4
5
6
7
8

PIN No.

GbE ASSIGNMENT

DA+

DA

DB+

DC+

DC

DB

DD+

DD

Installation

NWD-153831-01E

CONNECTING AND FORMING CABLES

5-14

5.6.3 Ethernet Port (Opt)

Indication:

P3,P4

Connector Type:

LC

Table5-3 Pin Assignment of Optical Port

1000BASE-SX/LX

PIN No.

Opt ASSIGNMENT

TX

RX

NWD-153831-01E

Installation

CONNECTING AND FORMING CABLES

5-15

5.6.4 Ethernet Port (FE)

Indication:

LCT

Connector Type:

RJ-45

Table5-4 Pin Assignment of LCT Port

RJ-45

1
2
3
4
5
6
7
8

PIN No.

Installation

FE ASSIGNMENT

TD+

TD

RD+

RD

NWD-153831-01E

CONNECTING AND FORMING CABLES

5-16

5.6.5 Power Port and Cable

Pin8

Pin6

Pin7

Pin3

Pin1

Pin5

Pin4

Pin2
Figure 2-2 Pin Assign (Power Port)

Table5-5 Pin Assignment of Power Port


Pin

Purpose

Ground

-48V

NWD-153831-01E

Installation

CONNECTING AND FORMING CABLES

Pin7

5-17

Pin8

Pin6

Pin1

Pin3

Pin4

Pin5

Pin2

Figure 2-3 Pin Assign (Power Cable)

Table5-5 Pin Assignment of Power Cable


Pin

Purpose

Ground (Red Cable)

-48V (Blue Cable)

Installation

NWD-153831-01E

5-18

CONNECTING AND FORMING CABLES

This page is intentionally left blank

NWD-153831-01E

Installation

GROUNDING THE FRAME

6-1

GROUNDING THE FRAME

When mounting iPASOLINK EX, ground the frame. The location of the ground terminal
on iPASOLINK EX method of Figure 6-1.

NOTES:
1. Connect the Frame Ground(FG) terminal on iPASOLINK EX to its rack using the erath
cable. In addition, connect the rack to the indoor earth terminal using the earth, and
connect the FG terminal in the iPASOLINK EX to the ground ( refer to Figure 6-1)

2. Screw torque should be within 132kgfcm

owerCable

Power Cable

Cautions:
1. Ensure to install iPASOLINK EX within the area protected by lightning rod.
2. To avoid surge currents caused by lightning circulating in the equipment earth
system,connect the equipment earth system (frame ground) to the ground of the lightning
rod at the ground level.

NOTES:
1.

2.

FrameGroundterminaloftheiPASOLINKEX(5mmsquarecable,whichmeansmorethan
2.5mmdiametercable;AWG#10)isrecommendedtoapplyfortheearthgrounding.The
properpressfixterminaltoolshallbeused.)
Screwtorqueshouldbewithin132kgfcm

Figure 6-1 Connection for Frame Grounding (Example-1/2)

Installation

NWD-153831-01E

GROUNDING THE FRAME

6-2

Power Cable

Notes:
* NEC recommends that frame ground of iPASOLINK EX should be connected to earth
line as NECs standard installation.
EP Earth Ground Point of tower.
FG Frame Ground terminal of the iPASOLINK EX (5mm square cable (means more than
2.5mm diameter cable(AWG#10) is recommended to apply for the earth grounding. The
proper press fix terminal tool shall be used.)

Figure 6-2 Connection for Frame Grounding (Example-2/2)

NWD-153831-01E

Installation

START UP / SHUT DOWN

7-1

START UP / SHUT DOWN

7.1 Start Up iPASOLINK EX

CAUTION:
Equipment surface may be hot during the operation. Ensure not to
touch the equipment.

1. Verify that the Power Cable or Ethernet Cable(PoE) connection.

2. Powering on the power supply or injector starts supplying the power to


iPASOLINK EX.

3. When the power is supplied, PWR LED (Green) and ONLINE LED(Green) at
DCN Port will blinking.

4. When iPASOLINK EX started up completely, PWR LED (Green) and


ONLINE LED(Green) will lights up.

5. For the first time only, the equipment starts up disabling the radio output.

WARNING:
Once the equipment is powered on, wait at least 5 minutes before
turning its power off. Repeatedly turning the power on and off
within a short interval may cause the equipment failure.

7.2 Check Reception Level

Refer to 8.ORIENTING ANTENNA for checking the reception levels.

Installation

NWD-153831-01E

START UP / SHUT DOWN

7-2

7.3 Shut Down iPASOLINK EX

1. Powering off the power supply or injector shuts down iPASOLINK EX.

WARNING:
Disconnecting Ethernet Cable from P1(PoE) Port while the
equipment is powered on may cause the equipment failure.

NWD-153831-01E

Installation

ORIENTING ANTENNA

8-1

ORIENTING ANTENNA

After the initial setup has been completed, an antenna orientation will be performed
between two stations according to the following procedure

8.1 Procedure
Apparatus

Digital Multimeter with test leads

Connect the PC to the LCT port on the iPASOLINK EX using LAN cable (see
Operation manual),

At each station, set Maintenance Control in LCT Menu,

Note

In Maintenance On condition, remote control can not be performed.

Click and select for the following control items in Maintenance Control,

Notes

1.

Retain the present status for other control items.

2.

When the TX power control mode is set to ATPC, se t it to MTPC and


required le vel for th e P ASOLINK link on the Equipment Setup and
Provisioning.

TX Power Control:
(at opposite site)

MTPC in Equipment Setup


Required level in Provisioning

At receiving station, remove a cap from the RX LEV MON jack,

At each station connect the digital multimeter to the RX LEV MON jack on the
iPASOLINK EX,

Installation

NWD-153831-01E

ORIENTING ANTENNA

8-2

At each station, adjust the azimuth and elevation angle of the antenna alternately
so that the measured voltage becomes maximum,

Note

The relation of the RX INPUT L EVEL versus RX LEVEL MON(V) is


shown below.

RX LEVEL MON vs RX INPUT LEVEL (Typical)

4.5

3.5

RX LEVEL MON [V]

2.5
2
1.5
1

0.5

0
-80

-70

-60

-50

-40

-30

-20

RX INPUT LEVEL [dBm]

NWD-153831-01E

Installation

ORIENTING ANTENNA

8-3

Digital Multimeter

RX LEV MON

Notes

1.

The RX LEV MON terminal on the iPASOLINK EX


(conformed to IEC61169-24).

2.

The RX LEV MON terminal must be capped for waterproof.

Caution: Be careful, surface of iPASOLINK EX is hot in operation.

Figure 11-2 Antenna Orientation Test Setup

Note

The fixed bolts and nuts to be used for the antenna orientation differ with
antenna bracket types, refer to antenna bracket shown in Figure 8-2.

Installation

NWD-153831-01E

ORIENTING ANTENNA

8-4

ANTENNA DIRECT MOUNTING TYPE

A. USING ANDREW BRACKET

Azimuth Angle Adjustment

A-1

Loosen bolts (1 in Figure 8-2),

A-2

Adjust the azimuth angle by adjusting bolt (2 in Figure 8-2),

A-3

Secure bolts loosened in step A-1,

Elevation Angle Adjustment

A-4

Loosen bolts (3 in Figure 8-2),

A-5

Adjust the elevation angle by adjusting bolt (4 in Figure 8-2),

A-6

Secure bolts loosened in step A-4.

1.

2.

3.

4.

Figure 8-2 Location of Adjusting Nuts and Bolts (ANDREW Bracket)

At each station, reset control items to original using LCT.,

NWD-153831-01E

Installation

ORIENTING ANTENNA

8-5

At each station, restore the MAINT Mode to off position using the LCT,

At each station, disconnect the digital multimeter from the RX LEV MON
connector,

10 At each station, reconnect the cap removed in step 4,

Note

The RX LEV MON connector must be capped for waterproof.

Installation

NWD-153831-01E

8-6

ORIENTING ANTENNA