Areas of Application
Preventive concrete protection against aggressive atmospheric pollutants
Surface protection for non-driven-on exterior areas
Carbonation protection in the course of concrete repair, while maintaining the diffusion capability of the
structures
Architectural colour design of exposed concrete structures
May be used in spray zones of de-icing salts
REACh-assessed exposure scenarios: periodical water-contact, periodical inhalation, application
Principle 1, 2 and 8; procedure 1.3, 2.2 and 8.2 (EN 1504-9)
Application
Substrate Preparation
See leaflet General Application Advice for Surface
Protection Systems
Application
Nafufill BS is ready-to-use and must be mixed
thoroughly before application. It can be applied by
roller, suitable airless-spraying method and by
worm pumps with adjustable discharge flow. If
planning to use spraying method please ask
for our assistance or the equipment planner
leaflet.
The product may not be applied in case of rain,
high humidity, frost or frost warnings. Freshly
applied coatings must be protected from dew, rain
and frost.
Standard Systems
Nafufill BS is usually applied in two layers. In combination with Emcephob WM (hydrophobic agent)
and with the fine fillers Nafufill KM 103 and Nafufill
KM 110, Nafufill BS is tested and approved as surface protection system.
Special Systems
On all other substrates priming with Betonflair
Uniprimer is necessary beforehand.
Afterwards Nafufill BS is applied in two layers.
Overcoating Time, Rain Proof
See table: Technical Data
General Information
Coverage rates depend on condition of the substrate which may lead to over- or under-consumption. Please observe the surface roughness
surcharges indicated in the Application Advice.
The colouring effect on the object also depends on
a number of factors, e.g. the light, the perspective,
the surrounding and substrate conditions (smooth/
rough, absorbent/impervious). The colouring effect
is therefore often a matter of subjective judgement. Choosing a shade from a small colour chart
is very difficult. We therefore recommend to apply
a trial area with the chosen system/colour code.
Joining areas should only be applied with material
from the same batch.
MC-Bauchemie Am Kruppwald 1-8 46238 Bottrop Tel. +49 (0) 20 41-101 10 Fax: +49 (0) 20 41-101 188
info@mc-bauchemie.de www.mc-bauchemie.de
Unit
Value*
Comments
Density
kg/dm3
1.02
1.54
Betonflair Uniprimer
Nafufill BS
seconds
50 texturally
viscous
Betonflair Uniprimer
Nafufill BS
Touch-dry
hours
approx. 1
Overcoating time
hours
approx. 1
24
approx. 1
on Betonflair Uniprimer
on Emcephob WM
on Nafufill BS
Diffusion resistance
against water vapour
0.1
Diffusion resistance
against carbon dioxide
> 200
Coverage**
ml/m2
approx. 100
2 x 130
Betonflair Uniprimer
Nafufill BS
Solid content
vol.-%
approx. 51
Nafufill BS
Rain proof
hours
3-6
Nafufill BS
Application conditions
C
%
K
8 - 30
85
3
Standard colours
Storage
Can be stored for at least one year in original unopened packs. Keep
dry and cool and protect from frost.
Disposal
EU-regulation 2004/42
(Decopaint standard)
MC-Bauchemie Am Kruppwald 1-8 46238 Bottrop Tel. +49 (0) 20 41-101 10 Fax: +49 (0) 20 41-101 188