DPX 125
MCCBs
P. 22
Dimensions
NEW
Energy metering
Isolating switches:
- Vistop
- DPX-IS
Proximity
switches,
fuse isolating
switches,
cartridge fuses
Protection
and
switching
NEW
Electrical
energy metering
(P. 28)
12
P. 28
Electrical
energy metering
on door
P. 31
DX-IS Isolating
switches
P. 39
Proximity switches
63A to 160A
P. 42
Domestic
cartridge fuses
P. 20
DPX
auxiliaries
P.21
Residual
current
relay coils
P. 34
DPX-IS 250
160A to 250A
P. 36
DPX-IS 630
400A to 630A
P. 38
DPX-IS 1600
800A to 1600A
P. 44
HRC blade type
cartridge fuses
P. 46
Technical
characteristics
P. 17
DPX 160
P. 18
DPX 250 ER
P. 25
Tripping curves
P. 26
Selectivity tables
P. 30
Electrical
energy metering
on Din rail
P. 32
Vistop 63A
to 160A
P. 40
SP fuse
carriers
P. 43
HRC
cartridge fuses
13
Mounting
Connection (2 options)
Via front terminals
Connect directly on plate (bar or cable with lug)
or via cage terminal (cables) or on a base
(for plug-in or draw-out versions)
Type of release
[thermal magnetic or electronic]
and breaking capacity [16, 25, 36, 50,
70 and 100 kA]
Size of unit:
125, 160, 250 ER, 250, 630, 1 250, 1 600
Version: fixed, plug-in or draw-out
[from 250 A]
A perfect t: in the new
XL3 cabinets and enclosures
Auxiliaries that are common
to the whole range
= 1 catalogue number
14
DPXTM MCCBs
electrical characteristics
DEVICES
DPX 125
DPX-E
16 KA
TYPE OF MCCB
1P
Number of poles
Nominal rating (A)
DPX 160
DPX
25 KA
DPX
36 KA
DPX
25 KA
3P - 3P + N/2 - 4P
16 - 125
16 - 125
DPX 250 ER
DPX
36 KA
DPX
50 KA
3P - 3P + N/2 - 4P
DPX
36 KA
DPX
50 KA
3P - 3P + N/2 - 4P
63 - 160
63 - 160
40 - 160
100 - 250
25
36
50
36
50
16
25
36
230 V
Breaking capacity Ics (% Icu)
16
22
35
40
40
50
65
50
65
50
100
50
75
100
75
50
75
50
Characteristics of use
50/60 Hz
Nominal frequency
Maximum rated operating voltage
Ue (V)
500 V - 250 V=
230 V
50/60 Hz
50/60 Hz
500 V - 250 V=
500 V - 250 V=
Category of use
Thermal-magnetic adjustment
Thermal
0.7 to 1 In
0.64 to 1 In
0.64 to 1 In
Magnetic
S2
70 mm2
95 mm2
185 mm2
50 mm
70 mm
150 mm2
12 mm (1)
18 mm (1)
22 mm (1)
6 Nm
10 Nm
10 Nm
Tightening torque
Nominal current (In) at 40 C (A)
In (A)
16
25
40
63
100
125
40
63
100
160
160
250
Phase
16
25
40
63
100
125
40
63
100
160
160
250
16
25
40
63
100
125
40
63
100
160
160
250
63
100
160
N/2
Magnetic threshold (Im) (A) (2)
Fixed
In (A)
16
25
40
63
100
125
40
63
100
160
160
250
Phase
480
625
800
950
1250
1250
400
630
1000
1600
1600
2500
480
625
800
950
1250
1250
400
630
1000
1600
1600
2500
950
N/2
1000
1600
(1) Copper bar only. (2) Trip current for 50/60Hz. For direct current, multiply by 1.5.
15
DPXTM 125
thermal magnetic MCCBs from 16 to 125 A
262 01
250 59
250 38
250 45 + 260 13
Pack
Cat. No.
Pack
Cat. No.
1
1
1
1
1
1
1
1
1
1
In
250 00
250 01
250 02
250 03
250 04
250 05
250 06
250 07
250 08
250 09
16 A
20 A
25 A
32 A
40 A
50 A
63 A
80 A
100 A
125 A
4P
260 02
260 03
63 A
In
260 12
260 13
125 A
262 01
Direct on DPX
Standard (grey)
262 75
262 76
Vari-depth handle IP 55
Comprising: connection rod, bracket, drilling template,
fixing accessories, door lock mechanism
Standard (grey)
For emergency use (red/yellow)
Rotary handles
DPX 125 - fixed version
3P
4P
250 36
250 37
250 38
250 39
250 40
250 41
250 44
250 45
250 46
250 47
250 48
250 49
3P
4P
250 50
250 51
250 52
250 53
250 54
250 55
250 58
250 59
250 60
250 61
250 62
250 63
In
16 A
25 A
40 A
63 A
100 A
125 A
1
1
Accessories
16
In
16 A
25 A
40 A
63 A
100 A
125 A
3P
262 05
263 00
DPXTM 160
thermal magnetic MCCBs from 40 to 160 A
262 11
251 72
251 25
251 33 + 260 21
Fixed version
Cat. No.
Pack
1
1
1
3P
4P
251 23
251 24
251 25
251 31
251 32
251 33
3P + N/2
Rotary handles
Cat. No.
Direct on DPX
1
262 11
Standard (grey)
Vari-depth handle IP 55
In
63 A
100 A
160 A
262 77
Standard (grey)
In
251 27
160 A
Accessories
3P
4P
251 49
251 50
251 51
251 57
251 58
251 59
In
63 A
100 A
160 A
3P
4P
251 62
251 63
251 64
251 65
251 70
251 71
251 72
251 73
In
40 A
63 A
100 A
160 A
3P
4P
262 15
262 16
262 18
262 19
262 17
Mounting plate
For mechanical interlocking of 2 DPX of the same
size for use in normal or automatic modes
264 01
3P
263 10
3P
4P
260 20
260 21
17
DPXTM 250 ER
For DPX 125 & DPX 250 ER, 630A, 415V, 50Hz rated chassis
tested at 36KA for 1s (76.6KA peak) in accordance with AS
3439-1:2002 clause 8.2.3
262 11
252 55
Fixed version
Cat. No.
3P
4P
252 24
252 25
252 26
252 34
252 35
252 36
3P
4P
252 44
252 45
252 46
252 54
252 55
252 56
In
100 A
160 A
250 A
264 02
Pack
Cat. No.
In
100 A
160 A
250 A
Pack
Cat. No.
Mounting plate
Rotary handles
Direct on DPX
262 11 Standard (grey)
Vari-depth handle IP 55
Comprising: connecting rod, bracket,
drilling template, fixing accessories,
door lock mechanism
262 77 Standard (grey)
Accessories
3P
1
1
262 85
Cage terminals
262 88 (1) Set of 4
For cable without lug 185 mm2 (rigid) or 150 mm2 (flexible)
for DPX 250 ER and DPX-IS 250
262 90
Spreaders
Set of incoming or outgoing spreaders
265 10
Rear terminals
Used to convert the fixed version with front terminals
to the fixed version with rear terminals
Set of upstream and downstream rear terminals
3P
18
mounting accessories
connection
Connection
DPX front terminals
Connection with cables
048 67
DPX 125 160 250 ER
D
12 18
18
262 08
252 25 +
DPX250ERLK
048 68
Cat. No.
Fixing plates
Distribution terminal
262 09
Insulated shields
160 A
47
6.5
250 A
12.5
60
26.5
10.5
16
6.5
10
30
17
10
25
Pack
262 00
Set of 3
80
56
Insulated shields
Distribution terminals
1
048 67
048 68
Padlocks
For locking in "off" position
1
262 00
262 10
1
1
19
DPXTM auxiliaries
DPXTM auxiliaries
Auxiliary contact or
fault signal
A single Cat. No. 261 60
auxiliary contact or fault signal
261 94
261 85
Pack
Cat. No.
261 60
Under-voltage releases
Releases
Allow remote tripping of a DPX
Shunt releases
For DPX-IS and DPX
Shunt inrush power 300 VA
261 64
261 67
For
DPX 125
DPX-IS
250, 630
Shunt releases
=
Coil voltage 230 V/=
Coil voltage 24 V /
Undervoltage releases
261 70
261 80
Coil voltage 24 V
261 71
261 81
Coil voltage 24 V
261 73
261 83
261 90
261 75
Undervoltage releases
For DPX/DPX-I 125, DPX -IS 250,630
261 85
Undervoltage releases
For DPX/DPX-I 160, 250ER, and DPX -IS 1600
modules
Device
Auxiliary contact
AC
EBAC
FS
Shunt release
or undervoltage release
Without
release
DPX-IS 250
Without
release
DPX-IS 630
With
release
DPX-IS 1600
AC = auxiliary contact
EBAC = "early" auxiliary contact
FS = break on trip contact
Pack
Cat. No.
261 94
20
Shunt release
or undervoltage release
Device
DPX 125
Weight: 0.900 kg
DPX 160
DPX 250 ER
NEW
45
35
88
260 98
90
60
44
35
260 88
Add residual current protection to DPX trip-free switches and DPX MCCBs
equipped with release
Coils
M
D
5
E
Adjustable sensitivity: 0.03, 0.05, 0.075, 0.1, 0.15, 0.2, 0.3, 0.5, 0.75, 1,
1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A
- 110 to 210 mm
5.5
(KQ\Z[HISL[YPW!ZLJVUKZ
:\WWS`]VS[HNL!=/a
260 88
Number of
modules
45 34
79
L
C
-VY\ZL^P[OJVPSZ!
- 35 and 80 mm
23
*VTWYPZLZ!
- a tinged, sealable window
- an auxiliary contact
- a green Led indicating energisation
- 3 yellow Leds indicating respectively the max. phase earth insulation
current: 20, 40 and 60 %
- a red Led indicating
Fixed: exceeding of the insulation fault current value
Flashing: breaking of one of the connections between coils and relays
22
Cat. No.
Pack
Cat. No.
260 92
260 93
260 94
260 95
260 96
260 97
A
35
80
110
140
210
150
B
75
108
148
177
270
225
C
85
132
170
206
295
259
D
42
67
86
104
150
133
E
92
125
165
200
290
245
H
36
36
36
36
44
275
L
43
65
84
102
145
95
M
56
56
56
56
64
113
Coils
21
5
260 92
260 93
260 94
260 95
260 96
260 97
260 98
58
1
1
1
1
1
1
1
25
371 92
Grey
Nominal
cross
section
(mm2)
4
Capacity
Rigid
Flexible
wire
wire
2
(mm )
(mm2)
0.25 to 4
0.25 to 4
Pitch
(mm)
310
30
368
400
21
DPXTM 125
Dimensions
Rotary handle-direct on DPX
60
75.5
32
25.4
103
12.7
81
A
Terminal shields
A
DPX 125
170
260
Fixed version, front terminals with earth leakage module mounted side by
side (1)
202
101
12.7
113.7
22
10
74
45
103
120
37.8
97
101
25.4
20
358.5 max.
173.5 min.(2)
0.8/2
62.5
(1) Dimensions of 3-pole earth leakage modules are the same as 4-pole earth leakage
modules
(2) 70 mm without mechanical system
39
10
74
M4
25.4
M8
M4
103
45
25.4
70
97
74
101
45
25.4 25.4
101
120
101
25.4
M4
48
40.2
80
M4
25.4
25.4
74
101
45
120
101
45
120
37.8
12
11.2
101
75.6
12
80
97
74
20
DPXTM 160
Dimensions
30
97
74
120
74
60
48
35
23
80
45
150
45
150
45
115
38.5 11.25
90
M4
1.5 max.
M4
30
18 max.
30
15
75.5
23
97
120
M4
74
30 30 30
74
358.5 max.
141.5 min.(2)
0.8/2
62.5
48
95
30 30
115
45
150
(1) Dimensions of 3-pole earth leakage modules are the same as 4-pole earth leakage
modules
(2) 70 mm without mechanical system
97
120
M4
60
132
150
86
95
30
==
74
45
Y
120
30
45
15
135
Y
Terminal shields
A
DPX 160
278
393
23
DPXTM 250 ER
Dimensions
Terminal shields
97
74
A
115
76.5
M4
max.
18
1.6
30 30 30
18
11.5
74
45
M4
20 max.
69
53.5
38.5
45
145
115
176
18
10 max.
120
30 30 30
90
97
296
DPX 250 ER
30
M4
74
270
150
30
30
30
176
145
1.5 max
15
75.5
69
53.5
38.5
115
215.5
38.5
80
30
35
15
11.25
30
115
30
60
48
20 max.
30
30
30
30
30
5
45
70
M4
74
358.5 max.
141.5 min.(2)
0.8/2
115
160 A
240
120
120
30
==
62.5
176
95
(1) Dimensions of 3-pole earth leakage modules are the same as 4-pole earth leakage
modules
(2) 70 mm without mechanical system
60
30
45
15
135
Y
24
DPXTM
reading DPX characteristic curves and adjustment ranges
selection table DPXTM / DPXTM thermal-magnetic
Tripping curve for a DPX thermal-magnetic
10 000
Ir overload
trip threshold
(thermal)
Im short-circuit
trip threshold
(magnetic)
t (s)
Thermal realease zone
when cold
1 000
DPX 125
DPX 160
DPX 250 ER
0.7 to 1 In
0.64 to 1 In
fixed: 10 In
(100 and
125 rating)
fixed: 10 In
100
10
1
Adjustable magnetic
realease zone
0.1
Im
0.01
0.001
3 4 5
10
20
30
50
100
I/Ir
I: actual current
Ir: thermal protection against overloads (setting: Ir = x In)
Im: magnetic protection against short-circuits (setting: Im = x In or Im = x Ir)
As the abscissa of the curves represents the ratio I/Ir, modifying the setting of Ir will not
change the graphical representation of the thermal trip. However, the magnetic setting
can be read directly (between 3.5 and 10 in the example).
125
1.25
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
0.63
1.6
1.6
2.5
2.5
2.5
1
1
1.6
1.6
1.6
2.5
2.5
2.5
2.5
25
DPX 125
36 kA
25
DPX-E 125
DPX 125 (1)
DPX 250 ER
36 kA
36
36
36
36
DX-H
10 kA
B and C (1)
curves
DPX 250 ER
2 to
32 A
40 to
63 A
16 to
125 A
16 to
125 A
63 A
1 to 20 A
25
125
16
25
25 A
25
125
16
25
32 A
125
16
40 A
125
100 A
160 A
250 A
25
25
25
25
25
25
25
25
25
25
25
25
25
16
25
25
25
25
25
50 A
16
25
25
63 A
16
25
1 to 16 A
16
25
20 A
16
25
25 A
16
32 A
MCBs downstream
DX-E 6 kA
DX-D
D (1) curve
25
20
20
20
15
15
25
25
25
25
25
25
25
25
25
25
25
25
25
16
25
25
25
25
25
40 A
16
25
25
25
25
25
50 A
16
25
25
25
20
20
63 A
16
25
25
20
15
15
20
80 A
20
20
100 A
20
20
20
15
15
125 A
(1) The magnetic threshold of the upstream circuit breaker must be higher than the magnetic threshold of the downstream circuit breaker
50 A
40 to
63 A
50
16 to
125 A
DPX-E
125
16 to
125 A
DPX 125
DPX 250 ER
63 A
100 A
160 A
250 A
25
22
35
50
50
50
25
22
35
50
50
50
50
16
25
36
36
36
36
63 A
16
25
30
30
30
80 A
16
25
25
25
25
100 A
16
25
125 A
DX-H
10 kA
B and C(1)
curves
50
25
25
25
25
1 to 40 A
22
35
50
50
50
50
50 A
16
25
36
36
36
36
63 A
16
25
30
30
30
(1) The magnetic threshold of the upstream circuit breaker must be higher than the magnetic threshold of the downstream circuit breaker
TT or TNS neutral earthing systems : For a 230/400 V supply in order to determine the breaking capacity of a 2 P MCB used as L + N (230 V) downstream a 2 P or 4 P circuit breaker use values indicated in the table for 230/240 V
Note: selectivity table - MCCBs (see previous page)
26
Technical information
10
16
20
25
32
40
50
63
80
100
Type B
21
21
24
25
11
11
15
17
24
31
45
55
125
-
Type C
21
21
24
25
11
11
15
17
24
31
45
55
88
78
156
Type D
21
21
24
25
11
11
15
17
24
31
45
55
88
78
156
Mechanical characteristics
Endurance: 20 000 mechanical switching operations
10 000 on load switching operations at In x cos 09
In ) 63 A
In * 80 A
25 Nm
3 Nm
In at 30 C
0 C
10 C
20 C
Ambient temperature
30 C
40 C
50 C
60 C
1
2
11
22
107
21
103
206
1
2
097
194
093
186
090
180
3
4
6
33
44
66
32
42
64
31
41
62
3
4
6
29
39
58
28
38
55
26
36
54
10
11
107
103
10
97
93
90
16
20
18
224
173
216
166
208
16
20
154
192
147
184
141
176
25
32
283
362
272
349
26
333
25
32
24
307
227
291
217
278
40
50
46
575
44
55
42
525
40
50
38
475
36
45
34
425
63
80
731
91
699
88
661
84
63
80
598
76
561
72
529
69
100
114
110
105
100
95
90
86
125
142
137
131
125
119
113
108
Technical information
Derating of MCBs according to the number of adjacent MCBs
Number of adjacent MCBs
Coefficient
from 1 to 3
from 4 to 6
from 7 to 9
over 10
08
07
06
27
146 65
146 61
Pack
047 79
Cat. No.
Pack
Cat. No.
Ammeters
Measure the intensity in amperes (A) of the current
Connected via a 0 - 5 A output current transformer (CT)
To be fitted with a measuring dial appropriate for the current to be
measured
1
146 01
Square barrel 68 x 68 mm
Measuring dial for ammeters
046 31
046 34
046 36
047 75
046 38
1
1
1
047 76
047 77
047 78
047 79
1
1
046 45
046 46
1
1
047 80
046 48
146 10
0 - 50 A
146 13
0 - 100 A
146 15
0 - 200 A
146 16
0 - 250 A
146 17
0 - 300 A
146 18
0 - 400 A
146 20
0 - 600 A
146 21
0 - 800 A
146 22
0 - 1000 A
146 66
0 - 1250 A
146 24
0 - 1500 A
146 25
0 - 2000 A
146 26
0 - 2500 A
146 28
1
1
1
0 - 4000 A
Voltmeters
Measure the voltage in volts (V) AC ou DC
Scale: 0 - 500 V
146 61
Square barrel 68 x 68 mm
Multi-function centrals
For measuring: current and voltage per phase, frequency, power factor,
active and reactive energy
Adapts to 3-phase balanced or unbalanced supplies with or without
neutral
Max. measurement: 8000 A
220 V
1
146 65
Standard
146 67
Communicating Modbus/JBUS
Data speed transmission: 1200 to 9600 Bauds
28
Current transformer
Frequency: 50/60 Hz
Precision class: 1.5 %
Operating temperature: - 10 C to + 40 C
Storage temperature: - 20 C to + 80 C
Consumption:
ammeter: 1.1 VA
voltmeter: 3 VA
Connection capacity: 2 x 2.5 mm2 with screws or
Conform to IEC 60051, VDE 0410, BS 89,
EN 60051-1, cenelec HD 223
Degree of protection: IP 20
Frequency: 50/60 Hz
Dimensions
Opening
for bar
width x th. (mm)
Fixing center
for fixing on
plate (mm)
50/5
100/5
200/5
21
16 x 12.5
on rail EN 50022
CT 300/5
23
20.5 x 12.5
25.5 x 11.5
30.5 x 10.5
50 x 45
CT 400/5
35
40.5 x 10.5
54 x 45
CT 600/5
800/5
1000/5
65 x 32
fix on bar
CT 1250/5
84 x 34
fix on bar
CT 1500/5
CT 2000/5
127 x 38
fix on bar
CT 2500/5
4000/5
127 x 54
fix on bar
Single phase CT
CT
Opening
for cable
max. (mm)
A
E
400
Dimensions (mm)
B
C
D
72
66.5
44
12
680,7
*VUZ\TW[PVU!
voltage: 0.5 VA / phase
current: 0.75 VA / phase
(\_PSPHY`WV^LYZ\WWS`!
single-phase voltage 230 V (196 to 253 V)
frequency 50 Hz (47 to 63 Hz)
self consumption 6 VA - 3.5 W
A
E
A
E
A
96x96
Dimensions (mm)
B
C
D
90x90
Output:
Energy pulse duration = 100 ms via volt free contact:
- for 5 A, 1 pulse/Wh
- from 20 to 150 A, 1 pulse/10 Wh
- from 200 to 1600 A, 1 pulse/100 Wh
- from 2000 to 8000 A, 1 pulse/kWh
Breaking capacity 110 V / - 50 mA
4-wire connection - 3 CT:
64.5
20
E
92x92
Input
2 5 8 11 1
Output
Supply
12 13
20 21
L1
L2
L3
N
29
046 81
046 72
046 74
046 65
Cat. No.
- 50/60 Hz
046 81
Up to 32 A
Display: LCD screens
6 digits including 1 decimal place
1 unit = 0.1 kWh
Partial counting with reset
Pack
Number
of modules
1
1
046 72
Up to 63 A
Display: LCD screen
6 digits including 1 decimal place
1 unit: 0.1 kWh
Partial counting with reset
With pulse transmitter to feed back remote
electronical energy consumption pulse
output: 1 imp/10 Wh
Technical characteristics
046 73
Number
of modules
Up to 63 A per phase
Power supply:
- 230 V - 50/60 Hz (3 phase)
- 400 V - 50/60 Hz (3 phase + N)
Programmable pulse output:
1 x 200 ms pulse every 1 kWh (default value)
30
046 74
Power supply:
- 230 V - 50/60 Hz (3 phase + N)
- 400 V - 50/60 Hz (3 phase + N)
Programmable pulse output:
1 x 200 ms pulse every 1 kWh (default value)
Current transformation ratio:
50/5 to 8000/5
Display:
3 green LED displays with manual selection:
- Current per phase
- Phase-to-phase voltage
- Phase voltage
- Instantaneous power: active, reactive and apparent
- Frequency and power factor (inductive/capacitive indication)
- Active energy
Unit of measurement: display according to the CT ratios
Automatic change of rating
Energy metering: totalising 9 digits in kWh, resolution 10 Wh
Input:
Voltage measurement consumption < 1 VA per phase
Current measurement consumption < 0.5 VA per phase
Auxiliary power supply:
Voltage 230 V single phase (+/- 10%)
Frequency 50 Hz (47 to 63 Hz)
Consumption < 6 VA - 3.5 W
Connection via a 0 - 5 A
current transformer (CT)
1
Multi-function centrals
Measure via a 0 - 5 A output current transformer (CT),
electrical values for low voltage applications:
For measuring current per phase, phase-to-phase voltage,
frequency, power factor, instantaneous power (active, reactive, apparent),
active and reactive energy
Adapt to 3-phase balanced or unbalanced supplies
with or without neutral
220 V - max. measurement: 8000 A
046 65 Standard
046 67 Communicating Modbus/JBUS
Data speed transmission: 1200 to 9600 Bauds
3-phase meters
Direct connection
Cat. No.
Output:
Energy pulse: duration > 100 ms
Via volt free contact
Connection
3 or 4-wire connection - 3 CT
isolating switches
selection chart
Front handle
63
Side handle
3P
4P
3P
4P
225 12
225 15
225 16
225 18
100
225 20
225 22
225 25
225 27
125
225 34
225 39
225 44
225 46
160
225 51
225 53
225 54
225 56
Front handle
3P
4P
Right-hand
Left-hand
side handle
side handle
3P
4P
266 12
3P
4P
160
266 02
266 22
250
266 03
266 07
266 13
266 17
266 23
266 27
400
266 60
266 62
266 64
266 66
266 68
266 70
630
266 61
266 63
266 65
266 67
266 69
266 71
800
265 91
265 95
with release
1 000
265 92
265 96
with release
1 250
265 93
265 97
with release
1 600
265 94
265 98
with release
Devices
3P
125
DPX-I 125
250 98
160
DPX-I 160
251 98
250
DPX-I 250 ER
252 98
250
DPX-I 250
253 98
400
DPX-I 630
255 86
630
DPX-I 630
255 88
800
DPX-I 1 600
257 94
1 250
DPX-I 1 600
257 96
1 600
DPX-I 1 600
257 98
2P
043 21
3P
16
1P
043 01
20
043 02
043 22
043 42
043 62
32
043 05
043 25
043 45
043 65
40
043 07
043 27
043 47
043 67
63
043 10
043 30
043 50
043 70
100
043 14
043 34
043 54
043 74
043 38
043 58
043 78
125
4P
DX-IS
VISTOP
DPX-IS
31
VistopTM 63 to 160 A
trip-free switches
225 15
255 88
250 98
Cat.No
DPX-I 125
In
3P
250 98
In
3P
251 98
125 A
DPX-I 250 ER
160 A
3P
252 96
252 98
Pack
Cat. No.
Front
handle
Side
handle
3P
255 86
255 88
1
1
3P
257 96
257 98
No of 17.5 mm
modules
1/10
225 12
225 16
3-pole
160 A
250 A
1/10
225 15
225 18
4-pole
1/10
225 20
225 25
3-pole
7.5
1/10
225 22
225 27
4-pole
100 A
In
250 A
125 A
1/10
225 34
225 44
3-pole
7.5
1/10
225 39
225 46
4-pole
DPX-I 630
1
1
Black handle
63 A
In
DPX-I 250
3P
253 98
225 18
Safety isolating switches with visible breaking of load and positive action of
the contacts
Double breaking of the phases by self-cleaning snap open/close action
contacts
Label holders for identification of the circuits
Connection via cage terminals tightened by Allen key (except 63 A ; by PZ 2
screws)
Screw-fixing or on EN 50022 4 rail (only on rail for 63 A Vistop)
Two versions for mounting on faceplate:
>P[OSLM[VYYPNO[L_[LYUHSZPKLOHUKSL^P[OZLHS[VTHPU[HPU[OL07WYV[LJ[PVU
(up to IP 55), mounting accessories, self-adhesive drilling template,
adjustable extension rod (30 to 170 mm)
>P[OKPYLJ[VYL_[LYUHSMYVU[OHUKSL^P[O*H[5V[VILVYKLYLK
separately
Possibility of attaching a 2-pole - 16 A auxiliary isolating switch Cat. No. 227 22,
or one or two N/C + N/O auxiliary Cat. No. 227 04/07
DPX-I 250 ER
1
1
In
400 A
630 A
DPX-I 1 600
In
1 250 A
1 600 A
4 rail xing
160 A
1/10
225 51
225 54
3-pole
7.5
1/10
225 53
225 56
4-pole
Vistop accessories
TM
Pack
Cat. No.
Auxiliary contacts
Set of 2 auxiliary switches for
on/off signalling 5A/250V
1/100
227 04
1/100
227 07
227 32
50
227 98
32
227 22
Vistop 63 to 160 A
TM
isolating switch
2 rail mounting
Electrical characteristics
78
C 2
83
63
45
22
6
C
44
m in . 1 1 4 - m a x . 5 2 3
32
24
C1
22,5
C2
83
66
63
45
Index of Protection
22
44
60
C
C1
C2
C1
C1
C1
C
Front handle
63 A
100 A, 125 A, 160 A
3 and 4-pole
3P
4P
125
133
160
17.7
26.7
90
91
16
50
100 A
cage
cage
4 to 352
4 to 502
Insulating voltage
690 V
(Ui)
Impulse resistant
8 kV
voltage (U imp)
400 V 63 A (35 kW)
AC 22 A
500 V 63 A (44 kW)
AC 23 A (1)
690 V 40 A (38 kW)
DC 22 A/250 V (1) (2)*
63
63
DC 23 A/250 V (1) (2)*
Breaking capacity
(Icu) (kA peak)
1 s resistant
current (kA rms) (Icw)
Icc
with fuses
(kA rms)
Fuse rupture
capacity
98
74
60
C 1
Terminals
Connec- Cu(flexible)
tion
Cu (rigid)
63 A
800 V
8 kV
100 A (55 kW)
100 A (69 kW)
100 A (96 kW)
125
125
125 A
160 A
switch
16 A (4)
cage
cage
cage
4 to 50 mm2
4 to 70 mm2
800 V
800 V
8 kV
8 kV
62
62
400 V
-
16 A
-
15
15
15
15
2,5
3,5
3,5
3,5
100
100
100
80
100
63 A
100 A (gG)
63 A (aM) (3)
125 A (gG)
125 A (aM) (3)
160 A (gG)
125 A (aM)
12
12
12
> 30 000
> 30 000
> 30 000
> 30 000
> 30 000
IP 2x B
(IP 3x C under
frontplates)
33
266 07
266 17
262 39
Isolating switches for on-load circuit breaking by visible isolation and positive action of the contacts
Padlock integrated in the handle
Connection with cage terminals
Supplied with terminal shields
Conform to IEC 60947-3
Category of use AC 23 A
Accept the same electrical auxiliaries as the DPX (p. 20)
Pack
Cat. No.
3P
4P
1
1
266 02
266 03
1
1
266 12
266 13
1
1
266 22
266 23
Pack
Rotary handles
Cat. No.
Front handle
Vari-depth handle IP 55
160 A
266 07 250 A
160 A
266 17 250 A
266 86
Accessories
Cage terminals
Mounting on rail
262 39
262 88 (1)
273 22
Set of 4
For cable 185 mm2 (rigid) or 150 mm2 (flexible) for DPX 250
ER and DPX-IS 250
Spreaders
Set of upstream and downstream spreaders
Rear terminals
Used to convert the fixed version with front terminals to the
fixed version with rear terminals
3P
4P
265 10
262 87
Set of 2
262 99
34
Electrical characteristics
160 A
150 mm
185 mm2
Width max. 28 mm
690 V - 250 V
800 V
Copper bar
Nominal rating (Ue)
Rated insulation voltage (Ui)
11.5
160 A
160 A
160 A
8.5
250 A
160 A
250 A
1
75
76.5
195
40 kA
12 kA efficient
100 kA efficient
250 A
160 A
105
72.5
85.5
70
160 A
74
35
40 kA
42
138
2500 operations
258
25000 operations
mechanical
electrical
(AC 23 - 400 V)
Index of protection
Endurance
45
11.5
(Icm)
129
60
AC 22 A
138
35
8 kV
400 V
690 V
690 V
AC 23 A
74
40.5
105
70
35
45
42
Cu flexible
Cu rigid / Alu
Connection
250 A
2
27
Rating
IP 20 front panel
40.5
Dimensions
Front handle
45
1.5
28
max.
1-6
74
Mounting
Mounted on rail with plate
11.5
18
35 35 35
160
195
55
195
50 min. 32
300 max.
11.5
42
M4
18
8
74
77
45
10 max.
18 max.
10 max.
M4
138
77
17.5
140
90
35 35 35
Spacer
262 99
40.4
90
227
195
35 35 35
45
77
42
138
107
132
M4
74
17.5
Plate 262 39
35 35 35
162
Distribution terminal
048 68
42
77
45
107
138
132
M4
90
35 35 35
17.5
74
162
35
266 70
262 50
266 62
Isolating switches for on-load circuit breaking by visible isolation and positive action of the contacts
Padlock integrated in the handle
Supplied with terminal shields, and cage terminals
Conform to IEC 60947-3
Category of use AC 23 A
Accept the same electrical auxiliaries as the DPX (p. 20)
Pack
1
1
Cat. No.
3P
4P
266 60
266 61
266 62
266 63
Pack
Cat. No.
262 50
Cage terminals
Front handle
400 A
630 A
Right-hand side handle
1
1
266 64
266 65
266 66
266 67
Accessories
400 A
630 A
3P
4P
262 48
262 49
266 68
266 69
266 70
266 71
400 A
630 A
263 50
263 51
263 52
263 53
Rotary handles
36
266 86
Spreaders
262 45
Set of 2
Padlock
For locking mechanism in open position
266 97
Ronis
DPX-ISTM 630
Technical characteristics
630 A
cage
43.5 43.5
48.1
17
M5
630
630
400
630
A
A
A
A
20 kA RMS
42
A
A
A
A
94
1 38
160
200
8 kV ac
400
400
400
400
26.4
105
100 kA
181
400 A
400 A
630 A
630 A
40 kA
15 000 operations
1 500 operations
1 3 0 .5
87
4 3 .5
1 0 8 .2
IP 20 front panel
48.1
43.5 43.5
105
0
90
1 6 5 .3
38.2
28
11
17
3 8 .7
26.4
42
15 max.
M5
200
138
1 8 3 .2
25 max.
43.5
43.5
94
Front handle
42
200
Dimensions
32 max.
132
90
Copper bar
Nominal Rating (Ue)
Rated insulation voltage (Ui)
Rated impulse withstand
voltage (Uimp)
400 V ac
AC 23 A
500 V ac
690 V ac
AC 22 A
690 V ac
I admissible ls (Icw)
I admissible with fuse
(kA efficient) (Icc)
Max. rating of fuse gG
Max. rating of fuse aM
Short-circuit
making capacity (kA efficient)
(Icm)
Mechanical endurance
Electrical endurance
(AC 23 400 V ac)
Index of protection
265
6 5 .3
Connection
297.4
Cu flexible
Cu rigid
3 3 0 .6
Rating
Terminals
8 1 .8
265
105
116
11
28
43.5
265
297.4
265
48.1
17
43.5 43.5
42
200
160
138
94
M5
132
90
105
26.4
43.5
43.5
43.5
181
37
800 to 1 600 A
accessories
Electrical characteristics
Rating
800 A
Connection
1 000 A
Alu
690 V
690 V
Rated impulse
withstand voltage (Uimp)
8 kV
262 65
Cat. No.
3P
4P
265 91
800 A
265 92
1 000 A
265 93
265 97 1 250 A
265 94
265 98 1 600 A
1 600 A
Cu rigide
Copper bar
265 98
1 250 A
Cu flexible
400 V
800 A
1 000 A
1 250 A
1 600 A
AC 23 A
500 V
800 A
1 000 A
1 250 A
1 600 A
690 V
800 A
1 000 A
1 250 A
1 600 A
DC 23 A
250 V
800 A
1 000 A
1 250 A
1 600 A
20 kA RMS
100 kA RMS
1 000 A
1 250 A
40 kA
Mechanical endurance
10 000
Electrical endurance
(AC 23 A - 400 V)
3 000
3 000
2 000
1 600 A
2 000
IP 20 front panel
Index of protection
Dimensions
Front handle with terminal shields
Mounting accessories
262 70
3P
4P
262 73
262 74
1
1
263 80
263 81
263 82
1
1
262 67
262 68
25
50
158
35
140
210
M12
M10
Terminal shields
downstream
Short terminals
Long terminals
38
94
24 max.
Cage terminals
262 69
205
100
298
320
Connection accessories
1
64
278
262 66
70
204
70
320
262 65
70
42
262 64
280
149
4P
280
3P
140
Cat. No.
63 A
226 15/17
Vistop 63 A p. 118
Characteristics
100 A
226 25/27
125 A
226 33/34
160 A
226 35/37
Dimensions
E
226 37
226 17
Pack
Cat. No.
Cat. No.
290
190
263
95
102
332
262
316
132
132
226 35/37
382
292
346
132
132
226 15/17
63 A
160 A
226 15
226 17
3P
cage terminals
50 mm2
4P
50 mm flexible
70 mm2 rigid
50 mm2
100 A - IK 07
Supplied with 2 cable glands 36P - ISO 50
1
226 25
3P
cage terminals
50 mm2
226 27
4P
50 mm2 flexible
70 mm2 rigid
50 mm2
125 A - IK 07
Supplied with 2 cable glands 36P - ISO 50
1
226 33
226 34
3P
cage terminals
50 mm2
4P
50 mm flexible
70 mm2 rigid
50 mm2
160 A - IK 07
Supplied with 2 cable glands 36P - ISO 50
1
226 35
3P
cage terminals
50 mm2
226 37
4P
50 mm2 flexible
70 mm2 rigid
50 mm2
39
SP fuse carriers
with protected terminals
058 06
058 28
215 04
216 01
Cat. No.
Single pole
10
10
058 06 (1)
058 08
8.5 x 32
10 x 38
058 18
10 x 38
Double pole
058 28
058 38
058 48
1
1
500 V
500 V
10 x 38
500 V
3-pole
10 x 38
3-pole + neutral
10 x 38
500 V
Cat. No.
Number
of 17.5 mm
modules
400 V
500 V
Pack
Voltage
215 01
Single pole
215 04
Triple pole
216 01
216 04
Triple pole
1 x 35 mm2
or
2 x 16 mm2
1.5
2
or
2 x 25 mm2
changeover micro-switch
057 96
057 99
216 36
Triple pole
1 x 50 mm2
or
2 x 25 mm2
Accessory
057 90
4.5
With 5 A - 250 V
3
Accessories
10
216 96
SP 51 or SP 58
Length 300 mm
Can be cut to
required length
40
No of
17.5 mm
modules
Blow-out indicator
Connection
SP 51 and SP 58
J
H
4.4
058 21
058 24
With label-holders
With insulated carrier class II O, padlockable
Coupling via supply busbars
Shielded terminals capacity 2 x 10 mm
Indicator to signal blown fuse with Cat. No. 057 90
Pack
Cat. No.
B2
B1
U
V
In mm
B1
B2
SP 51
SP 58
106
140
54.5
74
45
65
35
45
51.5
66
55
59
53
53
In mm
SP 51
SP 58
058 14
44
058 11
B1
B2
4.4
J
L
multi.
99
20.7
114 27
U
U
2P 3P
26.5 53
36
72
9
9
U
V
V
4P 1P 2P
79.5 26.5 53
108 36
72
H
1P
81
87
H
multi.
84
90
V
V
3P 4P
79.5 106
108 144
J
1P
96 --111
W
W
1 P multi.
87 90
101 109
Single pole
For
domestic
cartridges
10
10
10
10
10
058 10
058 11
058 12
058 13
058 14
10 A - 230 V
16 A
20 A - 400 V
25 A
32 A
Cartridge
dimensions
(mm)
of 17.5 mm
modules
Number
8.5 x 23
10.3 x 25.8
8.5 x 31.5
10.3 x 31.5
10.3 x 38
1
1
1
1
1
058
058
058
058
21
24
20
22
16 A - 230 V
32 A- 400 V
10A - 230 V
20A - 400 V
10.3 x 25.8
10.3 x 38
8.5 x 23
8.5 x 31.5
1
1
1
1
058 00
5 x 20
Voltage
250 V
Number
of 17.5 mm
modules
Choice of equipment
Type
Rated current
SP 51
50 A
SP 58
100 A
(125 A in 400 V)
Maximum cartridge
rating
400 V
500 V
690 V
gG aM gG aM gG aM
40
25 25
50
50
50
50 50
0.9
0.8
0.7
0.6
x
x
x
x
ln
ln
ln
ln
41
FUSE CARRIERS
>>>
Practical and
completely safe
102 63
Pack
Cat. No.
103 06
Miniature type 5 x 20
Instant reaction fuse - Ceramic body
Conform to IEC 60127 - NF EN 60127 VDE 0820-1
High rupture capacity (A)
For use with dimmers, Viking terminals and
emergency lighting units
10
10
10
10
10
10
10
10
10
10
10
10
102 02
102 05
102 06
102 10
102 12
102 16
102 20
102 25
102 30
102 50
102 63
102 96 (1)
Rating
Voltage
(Amps)
(Volts)
0.2
0.5
0.63
1.0
1.25
1.6
2.0
2.5
3.15
5.0
6.3
10.0
Rupture
capacity (Amps)
250
1500
250
500
Rating
Voltage
Rupture
Protected
(Amps)
(Volts)
capacity
section
(Amps)
(mm2)
Copper
103 06 (1)
6.3 x 23
6
10
10
10
10
113 02
113 04
113 06
113 10
8.5 x 23
2
4
6
10
10
10
10
116 06 (2)
116 10 (2)
116 16 (2)
10
10
10
10
10
10
10
10
10
123 01
123 02
123 04
123 06
123 08
123 10
123 12
123 16
123 20
10
10
10
126 16
126 20
126 25
10
133 32
10
10.3 x 25.8
6
10
16
230
6 000
1.5
230
6 000
1.5
230
6 000
2.5
400
20 000
2.5
400
20 000
400
20 000
8.5 x 31.5
1
2
4
6
8
10
12
16
20
10.3 x 31.5
16
20
25
10.3 x 38
32
Neutral links
10
10
123 00
133 00
8.5 x 31.5
10 x 38
(1) Overrating not described by standards
(2) Conform to BS 1361 (1971)
42
120 04
133 08
143 10
140 12
153 96
150 50
Cat. No.
Cylindrical type gG
Pack
Cat. No.
Rating (amp)
10
133 94
0.5
10
133 01
10
133 02
10
133 04
10
133 06
10
133 08
10
133 10
10
10
133 12
12
10
133 16
16
10
133 20
20
10
133 25
25
10
133 32
32
14 X 51mm 500 V, 100 KA HRC
10
143 02
10
143 04
10
143 06
10
143 10
10
10
143 16
16
10
143 20
20
10
143 25
25
10
143 32
32
10
143 40
10
10
10
10
10
10
10
10
10
10
130
130
130
130
130
130
130
130
130
130
92
95
01
02
04
06
08
10
12
16
10
10
130 20 (2)
130 25 (2)
20
25
10
10
10
10
10
10
10
10
10
10
10
140
140
140
140
140
140
140
140
140
140
140
2
4
6
8
10
12
16
20
25
32
40
40
10
10
140 45 (1)
140 50 (1)
45
50
10
10
10
10
10
10
10
10
10
150
150
150
150
150
150
150
150
150
16
20
25
32
40
50
63
80
96
16
20
25
32
40
50
63
80
100
10
150 97
125
10
10
10
10
123
133
143
153
8.5 X 31.5
10.3 X 38
14 X 51
22 X 58
50
22 X 58mm 500 V, 100 KA HRC
10
153 16
16
10
153 20
20
10
153 25
25
10
153 32
32
10
153 40
40
10
153 50
50
10
153 63
63
10
153 80
80
10
153 96
100
10
153 97
125
0.25
0.5
1
2
4
6
8
10
12
16
10 X 38mm 400 V, 100 KA HRC
10
Neutral links
00
00
00
00
43
168 35
178 65
Cat. No.
Pack
Cat. No.
10
10
10
10
10
10
10
10
10
10
163 18
163 20
163 22
163 25
163 30
163 35
163 40
163 45
163 50
163 55
With
striker
Size 00
25
32
35
40
50
63
80
100
125
160
500
120000
168 35
168 40
168 45
168 50
168 55
168 60 (1)
63
80
100
125
160
200
With
indicator
3
3
3
3
3
3
With
striker
160 25
160 30
160 35
160 40
160 45
160 50
Size 00
40
50
63
80
100
125
500
120000
400
Size 0
Size 0
3
3
3
3
3
3
Conform to EN 60269-1
IEC 60269-1, 2 and VDE 0636-1
Veritas approved
Fully insulated end plate and handle lugs
Rating
Voltage
Rupture capacity
(Amps)
(Volts)
(Amps)
With
indicator
3
3
3
3
3
166 35
166 40
166 45
166 50
166 55
3
3
3
3
170 50
170 55
170 60
170 65
3
3
3
3
175 60
175 65
175 70
175 75
3
3
180 25
180 30
63
80
100
125
160
500
120000
500
120000
500
120000
500
120000
Size 1
500
120000
171 60
125
160
200
250
Size 2
Size 1
3
3
3
3
173 50
173 55
173 60
173 65
125
160
200
250
500
120000
Size 3
Size 2
3
3
3
3
178 60
178 65
178 70
178 75
3
3
181 25
181 30
200
250
315
400
500
500
120000
500
630
Neutral blades
120000
Size 3
500
630
176 70
200
250
315
400
10
1
1
1
1
163 04
168 04
173 04
178 04
181 04
Size 00
Size 0
Size 1
Size 2
Size 3
44
160 00
160 05
199 16
Cat. No.
Number of
pole
Pack
Cat No.
199 02
10
199 09
Separation dividers
Amps
160 00
00
1P
100 A
10
199 15
Size 0
160 04
00
3P
100 A
10
199 16
Size 1
162 00
00
1P
125/160 A
10
199 17
Size 2
162 04
00
3P
125/160 A
199 18
Size 3
160 01
00
1P
100 A
160 05
00
3P
100 A
165 00
1P
160 A
165 02
1P
160 A
165 03
3P
160 A
170 00
1P
250 A
170 02
1P
250 A
170 03
3P
250 A
175 00
1P
400 A
175 02
1P
400 A
175 03
3P
400 A
Terminal shields
199 20
Size 00
10
199 21
Size 0
10
199 22
Size 1
10
199 23
Size 2
45
cartridge fuses
HRC cylindrical
Size 0 to 3 (continued)
Single pole with micro-switch
57.5
36
M8
Size 0 to 3
Single pole Cat. No. 160 01 - 162 00
10
D
C
7.5
D
7.5
7.5
57
15.5
84
20
39
Blade type
C
B
D2
D1
M
102
37.5
51.5
20
10
6
M8
37.5
57
84
25
100
L
E
15.5
120
7.5
J
68
Sizes 0 to 3
Single pole without micro-switch
J
1
200
175
72
25
30
25
150
80
28
68
35
46
38
13.5
20
10.5
10
85
215
2
225
200
78
30
30
25
170
80
32
83
35
58
39
13.5
20
10.5
10
90
229
3
250
210
91
41
30
25
158
83
35
92
35
68
40
14
20
10.5
12
94
242
Size 0 - 1 - 2
Triple pole
F
0
171
150
63
20
25
125
75
23
68
24
43
28
11.5
14
7.5
8
75
198
E
M
25
57.5
3
150
61
75
70
64
75
14
2.5
36
6
23
14.5
88
10
18
2
150
64
74
50
50
60
14
3
28
6
19
14.5
72
10
14.5
1
135
64
74
47
47
52
14
3
21
6
16
14.5
64
10
14.5
0
125
62
67
36
39
46
14
2.5
15
6
14.5
14.5
59
10
14.5
Size (mm) 00
A
78
B
44
C
52
D1
30
D2
E
46
F
G
2.5
H
15
I
6
J
K
L
59
M
10
N
14.5
B
A
Size (mm)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
C
6.3
10
13
16
120
B
31.5
38
51
58
25
A
8.5
10.3
14.3
22.2
100
Size (mm)
8 x 32
10 x 38
14 x 51
22 x 58
Removable handle
23
124
83
46
Size (mm)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
171
150
47
20
25
125
75
23
68
24
43
28
11.5
14
7.5
8
96
180
200
175
59
25
30
25
150
80
28
68
35
46
38
13.5
20
10.5
10
107
224
225
200
67
30
30
25
170
80
32
83
35
58
39
13.5
20
10.5
10
121
240
250
210
82
41
30
25
158
83
35
92
35
68
40
14
20
10.5
12
110
266
Size (mm)
A
B
C
D
0
171
48
144
67
1
200
62.5
180
81
2
225
68
204
93
selection charts
Downstream
maximum rating determined according to class
and voltage to obtain selection
aM
2
4
6
8
10
12
16
20
25
32
35
40
50
63
80
100
125
160
200
250
315
400
500
630
gG
1
2
2
2
2
4
6
8
10
12
12
16
20
25
36
40
63
80
125
125
160
200
250
Upstream
rating
aM cartridge fuse
(A)
Downstream
maximum rating determined according to class
and voltage to obtain selection
aM
1
2
2
4
6
6
10
12
12
20
20
25
25
40
50
63
80
100
125
160
200
250
315
400
2
4
6
8
10
12
16
20
25
32
36
40
50
63
80
100
125
160
200
250
315
400
500
630
1
2
2
4
4
6
10
16
20
20
25
32
40
50
63
80
100
125
160
200
250
315
400
gG
1
4
6
8
10
12
16
20
25
32
32
32
40
50
63
80
100
125
160
160
200
250
315
400
Motor protection
Motor three-phase
400 V
230 V
kW
0.37
0.75
1.1
1.8
2.2
3
4
5.5
7.5
10
11
15
18.5
22
25
30
45
55
75
80
90
110
132
160
Hp
In A
kW
0.37
0.5 1.8 0.75
1
3.5 1.5
1.5 4.4 2.2
2.5
7
3
3
8.7
4
4
11.5 5.5
5.5 14.3 7.5
7.5
20
11
10
27
15
13.5 35 18.5
15
39
22
20
52
25
25
64
30
30
75
37
35
85
45
40 103 55
60 147 75
75 182 90
100 239 110
160 260 132
125 295 160
150 356 200
180 425 250
218 520 315
Hp
0.5
1
2
3
4
5.5
7.5
10
15
20
25
30
34
40
50
60
75
100
125
150
180
218
270
340
430
500 V
In A kW
1.03 0.75
2
1.5
3.5 2.2
5
3.7
6.6
4
8.5 5.5
11.5 7.5
15.5 11
22
15
30 18.5
37
25
44
30
51
40
60
45
72
51
85
63
105 80
138 110
170 132
205 160
245 220
300
370 250
475 335
584 450
Hp
1
2
3
5
5.5
7.5
10
15
20
25
34
40
54
60
70
109
110
150
180
220
300
In A
1.5
2.6
3.8
5.9
6.5
9
12
18.4
23
28.5
39.4
45
60
65
75
89
112
156
187
220
310
340
450
610
360
472
608
10 x 38
ratings
gG
aM
4
2
6
4
8
4
12
6
16
8
20
10
25
12
20 (1)
20 (1)
14 x 51
22 x 58
ratings
ratings
gG
aM gG
aM
4
2
6
4
8
4
12
6
16
8
16
20
10
20
25
12
25
32
20
32
20
50
25
50
25
32
50
32
40
63
40
50
50 (1) 80
100
63
80
80
100
125 (1)
S. 00
ratings
gG
aM
25
32
50
50
63
80
100
125
125
160
20
25
32
40
50
63
80
80
100
125
Cartridges
S. 0
ratings
gG
aM
63
80
100
125
125
160
200
63
80
80
100
125
160
S. 1
ratings
gG
aM
125
125
160
200
250
125
160
200
250
S. 2
ratings
gG
aM
200
250
315
400
S. 3
ratings
gG
aM
200
250
315
315
400
500
630
47
The gG or aM types protect the conductors of electrical circuits in the event of overbad or short-circuit
gG cartridge fuses:
The selectivity ratio is 1.6 instead of 2
The breaking capacity of 120000 A provides full protection in the most critical situations
aM cartridge fuses:
These cartridge fuses must be combined with a low-overload thermal protection device
The breaking capacity of 100000 A from size 10 x 38 upwards provides full protection in the most critical situations
Cylindrical industrial cartridge fuses can be used to protect DC circuits supplied at up to 48 V max.
Times in seconds
10 000
100
125
160
200
250
315
400
500
630
gG type
10 000
1 000
1 000
Time in seconds
10 000
10 000
1 000
1 000
100
100
100
10
10
10
10
0.01
1
10
100
1 000
Current in Amps
0.01
100 000
10 000
0.1
0.1
0.1
0.1
25
32
40
50
63
80
100
125
160
200
250
315
400
500
630
100
0.01
1
10
100
1 000
Current in Amps
10 000 000
10 000
10 000 000
Thermal stress in A s
1 000 000
1 000 000
Thermal stress in A s
100 000
10 000
1 000
100
25
50
35
40
32
80
63
315
500
125
200
400
630
100
160
250
Rating in Amps
100 000
10 000
1 000
100
25
40
32
63
50
80
100
630
500
400
315
250
200
160
125
100
80
63
50
40
32
25
30
10
2.5
Ief
0.3
0.1
0.1
0.2
0.5
1
2
5
10
Prospective short-circuit at kA rms
20
50
100
(1) For aM cartridge fuses, see technical data sheets in the Legrand e-catalogue
48
Fuse
ratings (A)
25
32
35
40
50
63
80
100
125
160
200
250
315
400
500
630
Cartridge fuses
gG
Size 00
2.1
3
3
3.3
4.5
6
7
7.5
13
15
aM
Size 0 to 4
4.2
5.5
6.5
8.5
9.5
12
15
19
23
24
33
36
45
Size 00
1.3
1.8
2.5
3
3.6
5.2
6
7
Size 0 to 4
3.9
5.5
6.5
8.5
11.5
13.5
17
24
28
34
41
0.01
100 000
49
NEW
P. 56
DX-E; DX 6000
MCBs from
1 to 63A
Protection:
- DX
- DX-E
- DX-H
- DX-D
- RCD
- RCBO
P. 58
DX-D MCBs
up to 63A
D curve
P.64
Surge protection
Voltage surge
protectors, fuse
carriers and fuses
A1
1
Contactors and
time switches
2
P. 68
Modular
contactors
4
A2
P. 75
AlphaRex Astro
digital
Lexic
Din-rail
equipment
NEW
25 A
Power contactors
(P.68)
50
P. 57
DX-H 10000
MCBs from 1 to 63A
P. 58
DX-D
MCBs from 6 to 63A
P. 59
DX RCBO
RCD
P. 60
Auxiliaries
P. 61
Technical
characteristics
P. 66
Technical
characteristics
18
4
12
10
P. 73
AlphaRex
4 channel
digital
14
18
16
12
P. 79
Hour counter
16
10
P. 77
Electro-mechanical
surface mounting
14
P. 76
Electro-mechanical
Din
24
24
P. 72
EcoRex
digital
22
22
P. 71
MicroRex
digital
20
20
P. 70
AlphaRex
digital
51
52
DISTRIBUTION BOARDS
PROTECTION
(See p. 85)
ISOLATION
SWITCHES
VistopTM 63
to 160 A
(See p. 31)
VOLTAGE SURGE
PROTECTORS
(See p. 64-65))
Efficient protection
against lightning effects
NEW
POWER CONTACTORS
(See p. 68)
Can control loads
up to 63 A
PROGRAMMABLE
TIME SWITCHES
(See p. 70)
For switching ON
and OFF an electric circuit
for pre-programmed periods
LIGHT SENSITIVE
SWITCHES
(See p. 75)
Automatic control of
different loads, based
on lighting conditions
(nightfall/daybreak)
53
Designation
DX 6000 /6kA
1P
2P
3P
4P
1P
2P
1/2/3/6/10/13/
16/20/25/32
40/50/63
1/2/3/6/10/13/
16/20/25/32
40/50/63
1/2/3/6/10/13/
16/20/25/32
40/50/63
1/2/3/6/10/13/
16/20/25/32
40/50/63
1/2/3/6/10
16/20/25/32
40/50/63
1/2/3/6/10
16/20/25/32
40/50/63
B and C
B and C
B and C
B and C
B and C
B and C
230/400 V
400 V
400 V
400 V
230/400 V
400 V
Nominal frequency
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
240/415 V
415 V
415 V
415 V
240/415 V
415 V
6000 A
6000 A
6000 A
6000 A
6 000 A
6 000 A
6000 A
6000 A
6000 A
6000 A
6 000 A
6 000 A
6 kA
6 kA
6 kA
6 kA
10 kA
Curve B: 25 kA
Curve C:
0U(!R(
In > 32 A: 20 kA
6 kA
6 kA
6 kA
6 kA
10 kA
10 kA
100%
100%
100%
100%
100%
100%
500 V
500 V
500 V
500 V
500 V
500 V
6 kV
6 kV
6 kV
6 kV
6 kV
6 kV
20 000
20 000
20 000
20 000
20 000
20 000
10 000
10 000
10 000
10 000
10 000
10 000
2 500 V
2 500 V
2 500 V
2 500 V
2 500 V
2 500 V
Remote control
yes
yes
Add-on module
yes
-25 C to + 70 C
-25 C to + 70 C
-25 C to + 70 C
-25 C to + 70 C
-25 C to + 70 C
-25 C to + 70 C
Number of poles
Type of curve
Breaking capacity
Icu 50/60 Hz with 127/230 V supply
acc. to AS 60947-2 with 240/415 V supply
Endurance
(operating cycles)
mechanical
electrical
Operating temperature
54
DX 6000 /6kA
3P and 4P
1P
2P
3P, 4P
1P
2P
3P and 4P
1/2/3/6/10
16/20/25/32
40/50/63
1/2/3/6/10
13/16/20/25
32/40/50/63
80/100/125
1/2/3/6/10
13/16/20/25
32/40/50/63
80/100/125
1/2/3/6/10
13/16/20/25
32/40/50/63
80/100/125
1/2/3/6/10/
13/16/20/25
32/40/50/63
1/2/3/6/10
16/20/25/32
40/50/63
80/100/125
1/2/3/6/10
16/20/25
32/40/50/63
80/100/125
B and C
B and C
B and C
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
415 V
240/415 V
415 V
415 V
240/415 V
415 V
415 V
6 000 A
10 000 A
10 000 A
10 000 A
6 000 A
6 000 A
6 000 A
6 000 A
10 000 A
10 000 A
10 000 A
6 000 A
6 000 A
6 000 A
Curve B: 25 kA
Curve C:
0U(!R(
In > 32 A: 20 kA
25 kA
0U(!R(
In > 40 A: 25 kA
0U(!R(
In 50/63 A: 25 kA
In > 63 A: 16 kA
0U(!R(
0U(!R(
In > 63 A: 16 kA
0U(!R(
0U(!R(
In > 63 A: 16 kA
0U(!R(
0U(!R(
In > 63 A: 16 kA
10 kA
0U(!R(
In 25 A: 20 kA
In 32 A: 15 kA
In > 32 A: 12,5 kA
0U(!R(
In 25 A: 25 kA
In 32/40 A: 20 kA
In > 40 A: 15 kA
0U(!R(
In 25 A: 20 kA
In 32/40 A: 15 kA
In > 40 A: 12,5 kA
0U(!R(
In > 32 A: 10 kA
0U(!R(
In > 32 A: 10 kA
0U(!R(
In > 32 A: 10 kA
100%
75%
75%
75%
75%
80%
75%
500 V
500 V
500 V
500 V
500 V
500 V
500 V
6 kV
6 kV
6 kV
6 kV
6 kV
6 kV
6 kV
20 000
20 000
20 000
20 000
20 000
20 000
20 000
10 000
10 000
10 000
10 000
10 000
10 000
10 000
2 500 V
2 500 V
2 500 V
2 500 V
2 500 V
2 500 V
2 500 V
yes
yes
yes
yes
yes
(!yes
(!yes
yes
yes
yes
yes
yes
-25 C to + 70 C
-25 C to + 70 C
-25 C to + 70 C
-25 C to + 70 C
-25 C to + 70 C
-25 C to + 70 C
-25 C to + 70 C
55
DXTM 6 000
034 33
034 53
10
10
10
10
10
10
10
10
10
Cat. No.
064 68
Pack
C
curve
Nominal
rating
(A)
033 82
033 84
033 86
033 87
033 88
033 89
033 90
033 91
033 92
6
10
16
20
25
32
40
50
63
Number
of 17.5 mm
modules
1
1
1
1
1
1
1
1
1
1
1
1
1
10
10
1
1
1
1
1
1
Cat. No.
C
curve
Nominal
rating
(A)
063 68
063 69
063 70
063 72
063 74
063 76
063 77
063 78
063 79
063 80
063 81
063 82
1
2
3
6
10
16
20
25
32
40
50
63
034
034
034
034
034
034
034
034
29
31
33
34
35
36
37
38
6
10
16
20
25
32
40
50
2
2
2
2
2
2
2
2
034 39
63
3 pole - 400 V
C
curve
Nominal
rating
(A)
1
1
1
1
1
1
1
1
034 47
034 49
034 51
034 52
034 53
034 54
034 55
034 56
6
10
16
20
25
32
40
50
3
3
3
3
3
3
3
3
034 57
63
1
1
1
1
1
1
1
1
1
56
C
curve
Nominal
rating
(A)
034 89
034 91
034 93
034 94
034 95
034 96
034 97
034 98
034 99
6
10
16
20
25
32
40
50
63
1
1
1
1
5
5
1
1
1
1
1
1
C
curve
Nominal
rating
(A)
064 60
064 61
064 62
064 64
064 66
064 68
064 69
064 70
064 71
064 72
064 73
064 74
1
2
3
6
10
16
20
25
32
40
50
63
Number
of 17.5 mm
modules
4 pole - 400 V
Number
of 17.5 mm
modules
4
4
4
4
4
4
4
4
4
Number
of 17.5 mm
modules
1
1
1
1
1
1
1
1
1
1
1
1
Number
of 17.5 mm
modules
5
5
5
5
5
5
5
5
C
curve
063 76
Number
of 17.5 mm
modules
2
2
2
2
2
2
2
2
2
2
2
2
3-pole - 400 V
1
1
1
1
1
1
1
1
1
1
1
1
C
curve
Nominal
rating
(A)
064 80
064 81
064 82
064 84
064 86
064 88
064 89
064 90
064 91
064 92
064 93
064 94
1
2
3
6
10
16
20
25
32
40
50
63
Number
of 17.5 mm
modules
3
3
3
3
3
3
3
3
3
3
3
3
4-pole - 400 V
1
1
1
1
1
1
1
1
1
1
1
1
C
curve
Nominal
rating
(A)
065 55
065 56
065 57
065 59
065 61
065 63
065 64
065 65
065 66
065 67
065 68
065 69
1
2
3
6
10
16
20
25
32
40
50
63
Number
of 17.5 mm
modules
4
4
4
4
4
4
4
4
4
4
4
4
DX-H 10 000
thermal magnetic MCBs
high breaking capacity from 1 to 63A
C curve
069 20
068 60
070 00
069 46
Pack
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Cat. No.
C
curve
Nominal
rating
(A)
Number
of 17.5 mm
modules
068 52
068 53
068 54
068 56
068 58
068 60
068 61
068 62
068 63
068 64
068 65
068 66
063 83
063 84
063 85
1
2
3
6
10
16
20
25
32
40
50
63
80
100
125
1
1
1
1
1
1
1
1
1
1
1
1
1,5
1,5
1,5
Pack
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Cat. No.
C
curve
Nominal
rating
(A)
Number
of 17.5 mm
modules
069 32
069 33
069 34
069 36
069 38
069 40
069 41
069 42
069 43
069 44
069 45
069 46
064 95
064 96
064 97
1
2
3
6
10
16
20
25
32
40
50
63
80
100
125
3
3
3
3
3
3
3
3
3
3
3
3
4,5
4,5
4,5
1
1
1
1
1
1
1
1
1
1
1
1
C
curve
Nominal
rating
(A)
Number
of 17.5 mm
modules
069 12
069 13
069 14
069 16
069 18
069 20
069 21
069 22
069 23
069 24
069 25
069 26
1
2
3
6
10
16
20
25
32
40
50
63
2
2
2
2
2
2
2
2
2
2
2
2
3-pole - 400 V
4-pole - 400 V
1
1
1
1
1
1
1
1
1
1
1
1
C
curve
Nominal
rating
(A)
Number
of 17.5 mm
modules
069 92
069 93
069 94
069 96
069 98
070 00
070 01
070 02
070 03
070 04
070 05
070 06
1
2
3
6
10
16
20
25
32
40
50
63
4
4
4
4
4
4
4
4
4
4
4
4
57
DX-D 6 000
DXTM
066 36
066 71
Pack
1
1
1
1
1
1
1
1
1
Cat. No.
D
curve
Nominal
rating
(A)
Number
17.5 mm
modules
065 79
065 81
065 83
065 84
065 85
065 86
065 87
065 88
065 89
6
10
16
20
25
32
40
50
63
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
066
066
066
066
066
066
066
066
066
29
31
33
34
35
36
37
38
39
Cat. No.
Type AC
Double pole - 230/400 V
Sensitivity
074 02
Nominal
rating
(A)
Number
17.5 mm
modules
6
10
16
20
25
32
40
50
63
2
2
2
2
2
2
2
2
2
074 02
Maximum
rating
(A)
Number
of 17.5 mm
modules
63
30mA
Sensitivity
074 29
Maximum
rating
(A)
Number
of 17.5 mm
modules
63
30mA
066
066
066
066
066
066
066
066
066
49
51
53
54
55
56
57
58
59
6
10
16
20
25
32
40
50
63
58
7
T
Number
17.5 mm
modules
3
3
3
3
3
3
3
3
3
Maximum
rating
(A)
D
curve
Nominal
rating
(A)
Number
17.5 mm
modules
066 69
066 71
066 73
066 74
066 75
066 76
066 77
066 78
066 79
6
10
16
20
25
32
40
50
63
4
4
4
4
4
4
4
4
4
Number
of 17.5 mm
modules
074 55
30mA
32
074 56
30mA
63
4-pole - 400 V
1
1
1
1
1
1
1
1
1
4-pole - 400 V
Sensitivity
1
1
1
1
1
1
1
1
1
2 4
Nominal
rating
(A)
3-pole - 400 V
3-pole - 400 V
D
curve
2 4
DXTM 6 000
DXTM
RCBO up to 40 A - type AC
residual current devices - type AC
078 86
090 12
089 28
6064 12
Conform to AS/NZS61008-1
Pack
Cat. No.
Type AC
Single pole + neutral - 230V
Pack
Cat. No.
Sensitivity
1
1
1
1
1
1
1
078 79
078 84
078 86
078 87
078 88
078 89
078 90
10ma
30ma
30ma
30ma
30ma
30ma
30ma
Nominal
rating
(A)
Number
of modules
16
10
16
20
25
32
40
2
2
2
2
2
2
2
Type AC
(1) (2)
Single pole + neutral - 230V
Breaking capacity
10000 A - AS/NZS61009-1
Sensitivity
1
1
1
1
1
1
6064
6064
6064
6064
6064
6064
10
11
12
13
14
15
30ma
30ma
30ma
30ma
30ma
30ma
Nominal
rating
(A)
Number
of modules
10
16
20
25
32
45
1
1
1
1
1
1
1
1
1
1
1
1
089
089
089
089
089
089
09
10
11
16
17
28
Type AC
2 - pole - 230V
Sensitivity
Nominal
rating
(A)
Number
of modules
30ma
30ma
30ma
100ma
300ma
300ma
25
40
63
40
63
40
2
2
2
2
2
2
4 - pole - 400V
Neutral on right-hand side
1
1
1
1
1
1
1
1
089 93
089 94
089 95
089 96
090 00
090 12
090 13
090 14
Sensitivity
Nominal
rating
(A)
Number
of modules
30ma
30ma
30ma
30ma
100ma
300ma
300ma
300ma
25
40
63
80
40
40
63
80
4
4
4
4
4
4
4
4
59
073 50
Pack
073 54
Cat. No.
073 61
Pack
073 50
073 51
1
073 53
073 54
073 61
1
1
1
073 65
073 66
073 68
Auxiliary changeover
switch. 6 A - 250 V
Indicates the position of
the switches
Fault signalling changeover switch.
6 A - 250 V
Indicates tripping of the
MCB at a fault
Auxiliary changeover 6 A - 250 V
Z^P[JO^OPJOJHUILTVKPLK
to a fault signalling switch
Auxiliary changeover 6 A - 250 V
switch + fault signalling
Z^P[JOJHUILTVKPLK
to 2 auxiliary changeover
switches
Command auxiliaries
Shunt trip
Enable the MCB to be
tripped from a remote location
110 to 415 V
110 to 125 V
Minimum voltage trips.
Time delay adjustable
from 0 to 300 ms
24 V
48 V
230 V
044 42
=
=
Support for 4 mm
or 6 mm padlock for DX, DX-H,
MCBs and 2 P RCDs
0.5
Terminal shields
1
044 39
Accessories
Padlocking
Number
of 17.5 mm
modules
Signalling auxiliaries
1
Cat. No.
073 68
044 47
1
1
1
60
DX
B and C curves
D curve < 63 A
DX-H
B and C curves
DX D curve
80 to 125 A
DX-L
C curve
Icn 1
4500 A
6 kA
10 kA
25 kA
Ui
250 V
500 V
500 V
500 V
exible
s $8 SINGLE POLE NEUTRAL
with or without add-on modules
16
10
32
25
70
50
s !UXILIARIES
2.5
2.5
Consumption
U min.
U max.
12 to 48 V
110 to 415 V
522 mA
69 mA
2610 mA
259 mA
Undervoltage releases
nominal voltage (Un)
24 V
48 V
230 V
=
=
7\SSPU]VS[HNL!<U
Tripping time: from 100 to 400 ms 10% (adjustable)
Power consumption: 24 V= 0.1 VA
48 V= 0.2 VA
230 VA 1 VA
Thermal
(low overvoltage:
slow release)
1h
Z B
Magnetic
(high overvoltage:
fast release)
0.01 s
1
10
20 30 50
100
200
2 3 4 5
1.3
B
C
D
x In (rating)
1.45
Thermal release for an ambient temperature = 30 C
Curves
Z (1)
B
C
D
MA (1)
61
Protection of DC circuits
3L_PJ+?HUK+?/4*)Z77770U(KLZPNULKMVY\ZLPU
230/400 V supplies, can also be used in DC circuits
In this case, the following deratings and precautions must be taken into
account
1 - Protection against short-circuits
Max. magnetic tripping threshold: multiplied by 1.4
Example: For a C curve MCB for which the AC tripping threshold is
between 5 and 10 In, the DC tripping threshold will be between
7 and 14 In
DX-H LEXIC
Acc. to
voltage
single-pole
2P
48 V
10 kA
10 kA
110 V
10 kA
3P
4P
10 kA
230 V
15 kA
4 - Breaking capacity
4000 A for a single pole MCB at max. voltage (80 V= per pole)
At other voltages, the breaking capacities are as follows:
+
DX
voltage
Acc. to
48 V
single-pole
2P
6 kA
6 kA
110 V
6 kA
3P
10 kA
100 %
100 %
voltage
48 V
Acc. to
IEC 60947.2 Icu
single-pole
2P
10 kA
10 kA
10 kA
3P
110 V
230 V
single-pole
2P
48 V
6 kA
6 kA
110 V
6 kA
3P
4P
6 kA
10 kA
4P
10 kA
230 V
Ics (1)
voltage
230 V
100 %
110 V
48 V
100 %
230 V
DX-H
DX LEXIC
Acc. to
100 %
110 V
Ics (1)
6 kA
230 V
48 V
4P
15 kA
100 %
100 %
100 %
100 %
100 %
s )SOLATED EARTH SUPPLY:
Distribute the poles necessary for breaking over the 2 polarities to provide
protection in the event of a double earth fault (particularly if there are a
number of circuits in parallel)
voltage
single-pole
2P
48 V
6 kA
6 kA
110 V
6 kA
230 V
(1) As a % of Icu
62
3P
4P
6 kA
10 kA
(]LYHNL9*+VWLYH[PUNJ\Y]LZ
1
t(s)
Downstream
RCD
0.5
10mA
30mA
300mA
1A
2P/
4P
0.1
80 A 100 A
Upstream MCB
DX (B/C)
DX-H (B/C)
DPX
80 < DX-L 125
125 A
1P+N 2,3,4P ) 63 A
16 A
100 kA 50 kA 15 kA 10 kA
6 kA 10 kA 20 kA (1) 12.5 kA 50 kA 25 kA
25 A
100 kA 50 kA 15 kA 10 kA
6 kA 10 kA 20 kA (1) 12.5 kA 50 kA 25 kA
40 A
100 kA 50 kA 15 kA 10 kA
6 kA 10 kA 15 kA (1) 12.5 kA 50 kA 25 kA
63 A
100 kA 50 kA 15 kA 10 kA
80 A
100 kA 50 kA 15 kA 10 kA
100 A
100 kA 50 kA 15 kA 10 kA
10 kA
12.5 12.5 kA 50 kA 25 kA
kA(1)
12.5 12.5 kA
25 kA
kA (1)
12.5 12.5 kA
25 kA
kA (1)
0.05
I m according to EN 61009-1
Add-on modules
- DX 6000 , DX-H, D curve
6000 A
RCBOs
-P+N
3000 A
- 2P (4 modules)
6000 A
- 4P 10 to 32 A (4 modules)
4500 A
- 4P 40 to 63 A (7 modules)
6000 A
0.01
10
10
10
10
I (mA) 10
63
DISTRIBUTION BOARDS
>>>
Spacious
design
Legrand Distribution Boards are spacious
and expandable for control wiring. They are
designed to suit Commercial and Industrial.
039 21
039 33
039 34
Cat. No.
1
1
1
1
039 20 (1)
039 21 (1)
039 22 (1)
039 23 (1)
Number of
poles
Associated
protection
Number of
modules
1P
2P
3P
4P
40A - C curve
40A - C curve
40A - C curve
40A - C curve
1
2
3
4
039 30 (1)
039 31 (1)
039 32 (1)
039 33 (1)
Number of
poles
Associated
protection
1P
2P
3P
4P
20A - C curve
20A - C curve
20A - C curve
20A - C curve
Number
of modules
1
2
3
4
Ample space:
- space for additional din rail equipment
- extra space for cabling
- full accessibility from top and bottom
Ready to use:
- equipped with standard 250A main switch
Chassis:
- type tested up to 400A
- complete solutions from 24 poles to 84 poles
Designed and manufactured in Australia
64
1
1
1
039 40
039 41 (1)
039 43 (1)
(1)
Number of
poles
Associated
protection
1P
2P
4P
20A - C curve
20A - C curve
20A - C curve
Number
of modules
039 28
039 34
039 44
039 39
1
2
4
038 28
038 29
039 63
Cat. No.
1
1
038 28
038 29
Un
Up
(V)
(V)
170
48
260
100
039 56
039 57
039 58
1
1
039 62
039 63
Type 1 (T1)
Class I (T1)
Class B
10/350 s
Iimp (10/350)
In (8/20)
Type 2 (T2)
Class II (T2)
Class C
8/20 s
In, Imax
Number
of modules
2
4
65
Technical characteristics
Installation
Type 2 V.S.P.
(class II)
High
protection
(H)
Increased
protection
(I)
Standard
protection
(S)
039 20/21/22/23
039 30/31/32/33
039 40/41/43
TT - TN - IT
TT - TN - IT
TT - TN
440 VA
440 VA
320 VA
Cat. No.
10 kA
70 kA
40 kA
15 kA
20 kA
15 kA
5 kA
2 kV; 20 kA
1.5 kV; 5 kA
440 V
1.8 kV; 15 kA
1.3 kV; 5 kA
440 V
1.4 kV; 15 kA
1.2 kV; 5 kA
440 V
40 A
20 A
20 A
25 mm2
16 mm2
Main
board
Secondary
board
Type 2 V.S.P.
I or S protection
Proximity
protection
Analog
038 28
Digital
038 29
170 V
48 V
260 V
100 V
Mosaic or
P = Cliane
or similar
5 kA
0.5 to 2.5 mm2
Associated protection
The supply circuit of the VSP must be protected against short-circuits
and overloads by its associated disconnector (MCB) in accordance with
discrimination rules.
TT earthing systems, and V.S.P.: V.S.P. always installed downstream a
residual current device (RCD)
For the voltage surge protector to perform its function as well as possible,
it must be installed:
PUWHYHSSLS
RLLWPUNHZZOVY[HJVUULJ[PVUSLUN[OHZWVZZPISLIL[^LLU[OL
phase-neutral terminal block and the PE or PEN terminal block
PUHJJVYKHUJL^P[O,4*LSLJ[YVTHNUL[PJJVTWH[PIPSP[`Y\SLZ!
avoid the loops of conductors, fix the cables against metal
conductive parts
66
H level
Cross section
mm2
16
H level
Cross section
mm2
16
I level
10
I level
16
S level
S level
16
Type 2 V.S.P.
Type 1 V.S.P.
Downstream V.S.P.
Distance (m)
S level
type 1
E (S)
type 2
8 (10)
H level
type 2
S (P)
type 2
8 (10)
I level
type 2
S (P)
type 2
4 (6)
S level
type 2
type 2
+V^UZ[YLHT[OLJVTT\UPJH[PVUKPZ[YPI\[PVUIV_
- Analogue or digital
1st level
2nd level
(type 2 V.S.P.)
PE
- Digital
67
power contactors
NEW
from 16 A to 63 A
041 16
041 23
041 24
041 31
041 47
040 78
Cat. No.
I max
coil
041 14
Pack
Cat. No.
2-pole - 250 V
Type
Number
of contact of modules
16 A
N/C + N/O
24V
I max
coil (continued)
041 29
25 A
Type
of contact
Number
of modules
2 N/C
4 N/O
4 N/C
2 N/O + 2 N/C
230V
041 16
25 A
2 N/O
4-pole - 400 V
24V
4-pole - 400 V
1
041 17
25 A
4 N/O
24V
041 31
25 A
041 32
25 A
230V
230V
Manual override for test and repair function, carried out via the
handle
Permanent "ON" or "OFF" without automatic reset
2-pole - 250 V
I max
041 23
25 A
040 73(1)
63 A
041 24
4-pole - 400 V
1
040 74(1)
Type
Number
of contact of modules
24V
2 N/O
2 N/O
4 N/O
041 33
230V
25 A
63 A
25 A
4 N/O3
24V
Manual override for test and repair function, carried out via the handle
Permanent "ON" or "OFF" without automatic closing of the contactor
coil
041 49
I max
Type
Number
of contact of modules
25 A
2 N/O
230V
coil
2-pole - 250 V
I max
041 47
25 A
040 68(1)
40 A
040 75(1)
63 A
040 76(1)
63 A
040 69(1)
040 77
041 26
I max
Type
Number
of contact of modules
16 A
N/C + N/O
230V
3-pole - 400 V
041 58
25 A
230V
2 N/O
230V
230V
Type
of contact
Number
of modules
2 N/O
2 N/O
2 N/O
2 N/C
3 N/O
3 N/C
40 A
230V
(1)
63 A
4-pole - 400 V
10
041 48
4 N/O
040 70
(1)
25 A
40 A
4 N/O
040 78 (1)
63 A
4 N/O
040 79
63 A
4 N/C
230V
230V
(1) Handle can be accessed once the blanking plate has been removed
68
power contactors
power contactors
NEW
from 16 A to 63 A (continued)
from 16 A to 63 A
Technical characteristics
YH[LKPTW\SZP]LYLZPZ[HU[J\YYLU[<PTW!R=
TLJOHUPJHSSPMLPUJ`JSLZVMVWLYH[PVUZ!6 cycles
[LTWLYH[\YL!
- operation: - 25 C to + 40 C
- storage: - 40 C to +70 C
041 83
040 85
Pack
Cat. No.
041 85
Voltage
5A
250 V
For 2 module contactors 25 A
Changeover
switch
Number
of modules
N/C + N/O
0.5
041 83
Changeover
switch
Number
of modules
N/C + N/O
0.5
Voltage
Changeover
switch
Number
of modules
250 V
N/C + N/O
0.5
Voltage
5A
250 V
For 40 and 63 A contactors
040 85
5A
230 VA
Nominal current
16 - 25 A
25 A
25 A
16 - 25 A
16 - 25 A
Type of contact
N/O + N/C
2 N/C
4 N/O
2 N/O
N/O + N/C
2 N/O
2 N/C
230 VA
low noise
24 VA
Control voltage
Number of modules
Holding
Inrush
2 N/O + 2
N/C
4 N/O
4 N/C
2
200 mA
970 mA
300 mA
300 mA
6 mA
55 mA
20 mA
90 mA
20 mA
200 mA
Power contactors 40 A, 63 A
24 VA
Control voltage
230 VA
Nominal current
40 and
63 A
40 and
63 A
40 and
63 A
40 and
63 A
Type of contact
2 N/O
4 N/O
2 N/O
2 N/C
2
250 mA
1750 mA
3
270 mA
1500 mA
2
15 mA
150 mA
3 N/O
4 N/O
4 N/C
3
30 mA
200 mA
Number of modules
Holding
Inrush
s 2ECOMMENDATIONS
Derating of contactors mounted in modular boxes
if the internal temperature is > 40 C
Contactor rating
Ie = 16 A
Ie = 25 A
Ie = 40 A
Ie = 63 A
40 C
16 A
25 A
40 A
63 A
50 C
14 A
22 A
36 A
57 A
60 C
12 A
20 A
32 A
50 A
70 C
10 A
18 A
29 A
45 A
Install a spacing unit every two contactors (Cat. No. 044 40 or 044 41)
s -AX CONNECTION CROSS
SECTION IN MM2
Type of conductor
Ratings ) 25 A
Ratings 40
and 63 A
Rigid
Flexible
Flexible with single ferrule
Flexible with double ferrule
1 x 62 or 2 x 2.52
1 x 62 or 2 x 2.52
1 x 62
2 x 42
1 x 252 or 2 x 102
1 x 252 or 2 x 102
1 x 162
2 x 162
New range
Cat. No.
Designation
040 33
041 14
16 A - 24 V - N/C + N/O
040 41
25 A - 24 V - 2 N/O
040 43
25 A - 24 V - 4 N/O
040 38
041 26
040 49
25 A - 230 V - 2 N/O
040 52
041 49
040 50
041 29
25 A - 230 V - 2 N/C
040 53
25 A - 230 V - 4 N/O
040 54
041 32
25 A - 230 V - 4 N/C
040 55
041 33
041 85
040 85
041 83
040 85
(1) Without handle
69
Technical data
Type
Alpha Rex
D21
Alpha Rex
D22
2
running reserve
6 years
switching step
1 min
1 min
0,2 sec/day
accuracy
switching capacity
RESISTIVE 6^COS s =1
8 A~
INDUCTIVE 6^COS s =0,6
10 A~
1 SPDT
contact
047 73
16 A~
2 SPDT
56
programs1)
pulse start times
84
min.1 sec
max. 59 min,
047 61
pulse duration
59 sec
operating temperature
20 C
+55 C
IP20
(1) A program consists of an ON and an OFF time and the assigned days.
protection
AlphaRex Series
According to VDE 631-1 and 631-2-7, IEC 60 730-1 and 60 730-2-7,
EN 60 730-1 and 60 730-2-7
Ideal for school bells
Fast programming with selection of pre-set groups of days and individual
selection of days
Easy programming with PC using Legrand software and data key
Program consists of ON and OFF time with assignment to certain days
Backup possible on data key
With additional functions:
- holiday program
- random function
- pulse function (only 1 channel) with pulse duration of 1sec up to
59 min, 59 sec. and 84 start times
- hour counter for max. 65 535 hours.
Background lighting for display and buttons
Running reserve of 6 years for date and time
Programs are stored in a EEPROM
Programs are shown as a weekly matrix on the display
Automatic summer-/wintertime change (daylight saving)
Precision +/ 0,2 sec/day
Manual switching
Lead sealable cover, even with inserted data key
Wiring Diagram
AlphaRex D21
AlphaRex D22
Easy Programming
Pack
Cat. No.
AlphaRex D21
047 61
047 71
047 72
Data key
Transfer data into time switch
PC programmable
Can also be used as a backup
047 73
USB-adapter
To read and write data keys on a PC
Software and key 04772 included
Connection via USB-port
System requirements: Windows2000,
WindowsME, WindowsXP and
Windows98 second Edition,
0 MB free disc space
Serial adapter on demand
The data key makes work even more convenient. You can set up the program
easily on your PC and then save it on your data key. With the Legrand software and the adapter it is a piece of cake.
Created programs can easily be saved, edited, managed and used.
AlphaRex D22
70
Technical characteristics
Type
Channels
D21
D22 plus
2
6 years
Running reserve
1 min
+/-1 s/d
Accuracy
Switching capacity
Res. cos = 1
16A
Incad. lamps
5A
8A
changeover
(SPDT) 16A
Contact
Max. programs
28
14 channel
Operation temp.
-20 C - +55 C
Storage temp.
-20 C - +60 C
IP20
Protection
example:
1. prog.: ON 07:00h
2. prog.: ON 16:00h
3. prog.: ON 10:00h
CH1
CH2
CH1+2
Wiring Diagram
6047 74
Cat. No.
1
1
71
for rail
Technical Data
Cat. No.
037 05
Dimensions
Single channel
D11
1
0
037 05
2
123456 7
12
24
037 05
72
ON
5
4
86 x 17.5mm
Wiring diagram
Single channel
D11
Pack
OFF
PRE-PROGRAMMABLE
TIME SWITCHES
>>>
Easy to
program
Store and transfer data easily using a PC
and datakey
047 70
AlphaRex
to PC
PC to
AlphaRex
AlphaRex
to AlphaRex
Data Key:
transfer data
portable storage device
can also be safely stored in the AlphaRex
secure back up
Data key 047 81 can be used only with
AlphaRex DY64
AlphaRex DY64
Pack
Cat. No.
047 70
Accessories
1
1
047 81
73
Yearly Program
This menu item permits the input of (additional)
annual programs which are to be executed only during a
specified period. These programs and the weekly programs
of the same channel are ORed together
as described above. The period during which a
program is to be executed is defined by entering
a start date and an end date.
15:00:00
15:10:00
Channel
1
relay
Type
Number of channels
Power reserve
Exceptional Program
1 sec
1 sec
Switching capacity
Ohmic 230 V~cos =1
Filament lamp 230 V
Inductive 230 V~cos =0,6
Switch output
5 years
Switching increment
Accuracy
74
Alpha Rex
6
Programs1)
Control input with delay-time
Operating temperature
Type of protection
16 A~
8 A~
10 A~
4 SPDT
3 x 4 x 28 (336)
0 min
23h 59min
20 C + 55 C
IP20
Dimensions (mm)
047 70
M
120V/230V 50/60Hz
R6a -20T
2
ON
AUTO
OFF
ON
AUTO
OFF
83
0:04:00
0:04:00
Technical data
The option EVERY YEAR should be selected if the additional program is to be executed during the same period of each
year (e.g. Christmas, national holidays, birthdays, etc.).
15:30:00
0:10:00
15:32:00
0:04:00
15:20:00
0:10:00
0:10:00
4
ON
AUTO
OFF
ON
AUTO
OFF
120V/230V~50/60Hz
N S Ch1
66
107,7
047 70
M
120V/230V 50/60Hz
R6a -20T
2
ON
AUTO
OFF
ON
AUTO
OFF
4
ON
AUTO
OFF
ON
AUTO
OFF
120V/230V~50/60Hz
N S Ch1
AlphaRex Astro
037 55
037 21
037 40
037 44
047 64
Cat. No.
047 64
047 66
047 67
047 69
Cat. No.
1 module - 1 channel
24 hour Programme
037 30
8;^P[OOY^VYRPUNYLZLY]L/a
4PUPT\TZ^P[JO[PTLOV\YZ56*VU[HJ[8>
3 modules - 1 channel
24 hour Programme
Minimum switch time 45min - changeover switch
1
037 52
8;^P[OOY^VYRPUNYLZLY]L/a
4PUPT\TZ^P[JO[PTLOV\YZJOHUNLV]LYZ^P[JO8>
Microlux D
1
037 21
Remark:
The AlphaRex Astro can be programmed using the datakey
04772 and the programming software (see page 146)
75
>>>
Easy control
Easy Control of lights based on the of sunrise and
sunset, with no need of installing a light sensor!
MicroRex
Type
Cat. No.
T11
QT11
QW11
037 30
037 40
037 44
Supply voltage
Frequency
50 Hz
50/60 Hz
Switching
capacity for
cos = 1
50/60 Hz
16 A
Contact
On/off
Working reserve
None
100 hours
100 hours
Min. switching
time
15 minutes
15 minutes
2 hours
Interval
15 minutes
15 minutes
2 hours
Operating temp.
10 C + 55 C
Wiring diagram
Dimensions
60
1 7 5
M
~
44
2
3
4
5
U2
45
m ax.86
U1
MicroRex
Type
T31
QT31
037 52
037 53
QW31
Cat. No.
Supply voltage
Frequency
50 Hz
50/60 Hz
Switching
capacity for
cos = 1
Changeover switch
Working reserve
76
100 hours
100 hours
15 minutes
2 hours
Interval
30 minutes
4 hours
10 C + 55 C
Operating temp.
Dimensions
Wiring diagram
60
53
M
~
44
U1
U1 U2 1 4 2
45
None
Min. switching
time
Max. 90
50/60 Hz
16 A
Contact
037 55
U2
surface mounting
MaxiRex
Type
Cat. No.
QT
497 50
EconoRex
497 54
QW
497 52
BTAP
499 81
497 56
499 81
230 V+10% 15%
Supply voltage
50/60 Hz
50 Hz
Frequency
50 Hz
50/60 Hz
50 Hz
Switching capacity:
cos = 1
16 A
cos = 06
10 A
8A
1 000 W
1 000 W
incand. lamp
16 A
0499 81
1 c/o
Contact
1 c/o
1 c/o SPDT
SPDT
1499 81
1 n/o
Working reserve
None
Min. switching
100 hrs
None
100 hrs
None
10 mins
1 hrs
15 mins
20 mins
2 hr
15 mins
time
497 54
Interval
IP 20
IP rating
497 50
Dimensions
MaxiRex
TM
4 4 5
34
20
72
4 5
>P[OOY^VYRPUNYLZLY]L/a8;
7 day - 1 channel
1
1
Pack
497 52
Cat. No.
66
65
1
1
Maxirex
0 C + 55 C
72
Cat. No.
10 C + 60 C
Storage temp.
Operating temp.
110
Pack
IP 40
3 3 5
s /N DIN RAIL
with accessory
044 09
77
6499 18
Type
MaxiRex4
No. of channels
Switching capacity
Cos = 1
incandescent
ind. Cos = 0,6
20 A~
4 A~
10 A~
Operating temperature
-10 + 50
Protection modus
IP 53
(with plastic box)
6499 17
Pack
Cat. No.
6499 18
6499 17
6499 15
8;=/a^P[OV\[WSHZ[PJIV_
6499 14
8;)=/a^P[O07LUJSVZ\YL
Econorex M TM
24 hour - 1 channel
Programmable for 15 minutes minimum at
15 minute intervals with retained pull out segments
Easily programmed, easily read by user
Just set actual time to pointer and pull out segments
70
51
499 86
7HULSTV\U[PUN_TT48;>/^VYRPUNYLZLY]L
3
6
119.5
120
150.6
499 83
171.2
144.5
12
9
49
U1
U2
649 949
78
2 U1
U2
2 3
4 5 6
495 55
499 26
Hour counters
48 x 48 mm
AC current - design : 0...99999.99 hr
DC current - design : 0...999999.9 hr
IP 40 Panel flush mounting
Voltage supply:
- 50 Hz
- 50 Hz
495 52
24 V
Dimensions
495 55
240 V
48.5
495 60
12-36 VDC
32
0000123 h
45
50
45
046 94
046 94
046 91
- 50 Hz
24 V - 50 Hz
modules
230 V
2
2
(=JVZ $
IP 30
24 hour programme
The timer can repeat one or two settable short programmes within 24
hours
Shortest switching sequence
2.5 hours - up to 9 times
1 switching step = 1 segment = 30 min.
With two changeover contacts
Without working reserve
- 50 Hz
499 26
79
G
D
45
80
C
F
Notes
81
Distribution
cabinets and
consumer units
Distribution
cabinets,
enclosures
and
connection
Distribution
boards
(P. 85)
82
P. 84
Modular boxes
P. 85
Distribution boards
24P to 84P
P. 85
Supply busbars,
entry terminals
P. 86
Modular
distribution
blocks
83
013 04
Pack
Cat No.
013 08
Self-extinguishing: resistance to
incandescent wire 750C distribution boxes
IP30 - IK05
White RAL 9010
Cover directly clip shut and sealable
Capacity in modules
of 17.5 mm
10
10
10
5
1
013 01
013 02
013 04
013 06(1)
013 08(2)
1
2
4
6
(8 + 1)
x 30 x
x 50 x
x 90 x
x 128 x
x 190 x
47.5
72
72
74
74
83
Cat.Nos
013 01
30
72
140
120
10
013 02
50
72
140
115
25
013 04
90
74
160
130
45
013 06
128
74
160
125
80
013 08
190
83
180
130
120
14.5
84
103
Dimensions (mm)
Height x Width xDepth
140
140
160
160
180
Connection accessories
049 14
049 26
049 05
049 44
Standard distribution
Pack
Cat. No.
Distribtution Boards
Pack
1
1
1
1
1
1
HPM0800L - 24
HPM0800L - 36
HPM1000L - 48
HPM1000L - 60
HPM1200L - 72
HPM1200L - 84
1
1
1
1
1
1
HPM0800L2425F
HPM0800L3625F
HPM1000L4825F
HPM1000L6025F
HPM1200L7225F
HPM1200L8425F
50
10
049 38 (1)
049 39
Double pole
1 row
Meter
3
10
049 40 (1)
049 41
40
10
049 42 (1)
049 43
Triple pole
1 row
Meter
4
19
30
10
049 44
049 45
Four pole
1 row
Meter
3
14
Protection
Protection of prongs
12 modules
Can be cut to length
40
20
20
049 89
049 90
049 91
20
049 05
Main Switch
20
049 06
6022 10
6022 11
6022 12
6022 13
6022 14
6022 15
2046 39
3 Pole 250A
Entry terminals
Technical characteristics
Busbars
types
Single pole or
Single pole + neutral
External Dimensions
6
28
049 88
1
1
1
1
1
1
13
57
20
6820 84
04129
04132
1 row
Meter
049 26
049 37
Chassis 3 Pole
1
1
1
number of
devices connected
20
10
Cat. No.
250 A Distribution Panels with 250A chassis
for 17.5mm module MCBs Escutcheon included
Without Main Switch
24 pole
36 pole
48 pole
60 pole
72 pole
84 pole
With 250A Main Switch
24 pole
36 pole
48 pole
60 pole
72 pole
84 pole
Max.
Length
Height
(mm)
Width
(mm)
Depth
(mm)
800
800
1 000
1 000
1 200
1 200
600
600
600
600
600
600
200
200
200
200
200
200
No
Poles
24
36
48
60
72
84
Distribution Board
Without
Main Switch
Cat. No
HPM0800L - 24
HPM0800L - 36
HPM01000L - 48
HPM01000L - 60
HPM01200L - 72
HPM01200L - 84
With
Main Switch
Cat. No
HPM0800L2425F
HPM0800L3625F
HPM1000L4825F
HPM1000L6025F
HPM1200L7225F
HPM1200L8425F
Double pole
Double pole
balanced on 3-phases
Triple pole
Four pole
Pack
20
1 row
Meter
1 row
Meter
1 row
Meter
1 row
Meter
1 row
Meter
Max.
Length Cross
Permissible current:
number in number section 1 central
2 power
of devices of 17.5 mm (mm2)
power
connected modules
supply point supply point
13
13
162
80
100
57
57
63
90
6
12
102
28
56
162
80
100
6
12
102
63
90
28
56
162
80
100
4
12
102
63
90
19
57
162
80
100
3
12
102
63
90
14
56
162
80
100
Cat. No
016 56
85
048 68
8.5
6 to 25
376 68 to 71
10
6 to 35
376 68 to 77
8.9
6 to 25
376 68 to 71
12
5.3
16 to 50
1.5 to 10
376 64 to 69
10
1.5 to 10
16 to 35
376 70 to 77
70 to 150
2.5 to 10
376 66 to 69
8.5
2.5 to 16
10 to 25
376 69 to 77
10 to 35
70 to 120
5.3
2.5 to 10
1.5 to 10
376 64 to 69
7.5
10 to 25
6 to 16
376 68 to
70/77
11
4.3
1.5 to 4
0.75 to 4
376 62 to 67
6 to 16
4 to 10
376 67/68/69
11
5.3
2.5 to 10
1.5 to 10
376 64 to 69
7.5
10 to 25
6 to 16
376 68 to
70/77
10 to 35
10 to 25
376 69/72/71
5.3
35 to 70
1.5 to 10
376 64 to 69
7.5
2.5 to 10
6 to 16
376 68/69/77
8.9
6 to 25
10 to 25
376 69/72
10 to 35
25 to 50
376 71 to
77/78
5.3
2.5 to 10
1.5 to 10
376 64 to 69
7.5
10 to 25
6 to 16
376 68 to
70/77
11
4.3
1.5 to 4
0.75 to 4
376 62 to 67
6 to 16
4 to 10
376 67/68/69
5.3
2.5 to 10
1.5 to 10
376 64 to 69
7.5
10 to 25
6 to 16
376 68 to
70/77
(mm)
048 67
6
4
048 71
Flexible conductors
with ferrules
Starx
ferrules
Cat. No.
Number
048 88
Rigid
conductors
Section
(mm2)
Cat. No.
048 68
048 77
Connections
per bar
Section
(mm2)
376 70 to 77
Cat. No.
048 73
048 80
048 81
048 82
Double pole
Equipped with 2 bars
Isc
Rating
peak
(A)
(k)
5
10
5
048 81
048 80
048 82
40
100
125
Icw
(kA)
20
20
18
Number
of modules
3
4.5
4.5
6
4
8
Four pole
5
10
5
5
1
1
048 85
048 84
048 86
048 88 (1)
048 79 (1)
048 77
048 83
048 84
3
4.5
4.5
4.2
8.4
14.4
6
4
6
8
10
9
048 85
048 86
048 88
048 71
048 83
160
27
048 73
250
60
10 to 35
10 to 25
376 69/77
5.3
2.5 to 10
1.5 to 10
376 64 to 69
8.5
10 to 35
6 to 25
376 68 to 71
35 to 70
35 to 70
376 77/78
1
048 79
Single pole
Rating
(A)
125
2
11
5.3
2.5 to 10
1.5 to 10
376 64 to 69
7.5
10 to 25
6 to 16
376 68 to
70/77
8.5
10 to 35
10 to 25
376 69/77
2.5 to 16
2.5 to 10
376 66 to 69
7.5
10 to 25
6 to 16
376 68 to
70/77
8.5
10 to 35
10 to 25
376 69 to 77
Distribution terminals
10
16 to 50
16 to 35
376 70 to
72/77
50 to 120
50 to 120
376 78
048 67
048 68
048 77
86
Conform to EN 60947-1
Insulating voltage according to EN 60947-1 / IEC 60664-1: 500 V
Impulse voltage (Uimp): 8 kV - Degree of pollution: 3
Use in DC: without derating
Self-extinguishing 960 C on active parts supports
60
44
144
44
50
23
Cat. No.
Width
(mm)
048 80
048 81
048 82
048 84
048 85
048 86
048 88
048 77
048 79
70
105
140
70
105
105
140
160
179
101.5
45
49
39
23
104.5
Connection
86
88.5
125 A
250 A
36
36
Torque
3.5 Nm
44
50
160 A
Torque
3.5 Nm
Torque
24 Nm
10 Nm
23
96.8
91.5
Cat.No 048 71
Cat.No 048 83
Cat.No 3
250 A
44
50
25
45
10
75
150
85
5.5
134.5
70.5
75
Derating
Voltage
Rating
400 V
80 A
048 81
400 V
40 A
048 82
400 V
100 A
048 84
400 V
80 A
048 85
400 V
40 A
048 86
400 V
100 A
048 88
400 V
100 A
048 79
400 V
100 A
87