Vous êtes sur la page 1sur 76

P.

16
DPX 125

MCCBs
P. 22
Dimensions

NEW
Energy metering

Isolating switches:
- Vistop
- DPX-IS

Proximity
switches,
fuse isolating
switches,
cartridge fuses

Protection
and
switching
NEW
Electrical
energy metering
(P. 28)

12

P. 28
Electrical
energy metering
on door

P. 31
DX-IS Isolating
switches

P. 39
Proximity switches
63A to 160A

P. 42
Domestic
cartridge fuses

P. 20
DPX
auxiliaries

P.21
Residual
current
relay coils

P. 34
DPX-IS 250
160A to 250A

P. 36
DPX-IS 630
400A to 630A

P. 38
DPX-IS 1600
800A to 1600A

P. 44
HRC blade type
cartridge fuses

P. 46
Technical
characteristics

P. 17
DPX 160

P. 18
DPX 250 ER

P. 25
Tripping curves

P. 26
Selectivity tables

P. 30
Electrical
energy metering
on Din rail

P. 32
Vistop 63A
to 160A

P. 40
SP fuse
carriers

P. 43
HRC
cartridge fuses

13

MCCBs: DPX Characteristics


DPX are MCCBs and trip-free switches, known as moulded case circuit breaker,
for controlling and protecting circuits up to 1 600 A

The DPX system from 16 to 1 600 A

Mounting

Simple, set criteria for selecting a DPX

DPX 125, 160 and 250 ER are mounted on 2 rail.


They can also be installed on special plates

Connection (2 options)
Via front terminals
Connect directly on plate (bar or cable with lug)
or via cage terminal (cables) or on a base
(for plug-in or draw-out versions)
Type of release
[thermal magnetic or electronic]
and breaking capacity [16, 25, 36, 50,
70 and 100 kA]
Size of unit:
125, 160, 250 ER, 250, 630, 1 250, 1 600
Version: fixed, plug-in or draw-out
[from 250 A]
A perfect t: in the new
XL3 cabinets and enclosures
Auxiliaries that are common
to the whole range

Connection via cables

Connection via bars

Via rear terminals


Connect bars or cables with lugs to the rear terminals
mounted directly on the devices (fixed version) or on
bases (for plug-in or draw-out versions)

DPX can also be used with earth


leakage modules
Legrand Advantages
1. device

= 1 catalogue number

2. Single installation principle irrespective of


the device rating or version

Connection via bars

3. Mounted under faceplate in standard or


optimised distribution solutions

For products above 250A please


consult us.

14

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DPXTM MCCBs
electrical characteristics

DEVICES

DPX 125
DPX-E
16 KA

TYPE OF MCCB

1P

Number of poles
Nominal rating (A)

DPX 160

DPX
25 KA

DPX
36 KA

DPX
25 KA

3P - 3P + N/2 - 4P

16 - 125

16 - 125

DPX 250 ER

DPX
36 KA

DPX
50 KA

3P - 3P + N/2 - 4P

DPX
36 KA

DPX
50 KA

3P - 3P + N/2 - 4P

63 - 160

63 - 160

40 - 160

100 - 250

25

36

50

36

50

Breaking capacity (kA) (EN 60947-2


and IEC 60947-2)
400 V

16

25

36

230 V
Breaking capacity Ics (% Icu)

16

22

35

40

40

50

65

50

65

50

100

50

75

100

75

50

75

50

Characteristics of use
50/60 Hz

Nominal frequency
Maximum rated operating voltage
Ue (V)

500 V - 250 V=

230 V

50/60 Hz

50/60 Hz

500 V - 250 V=

500 V - 250 V=

Category of use

Thermal-magnetic adjustment
Thermal

0.7 to 1 In

0.64 to 1 In

0.64 to 1 In

Magnetic

fixed (10 x In)

fixed (10 x In)

fixed (10 x In)

Electronic protection adjustment


S1

S2

Maximum cable cross-section


Rigid cable
Flexible cable
Copper bar and lug width

70 mm2

95 mm2

185 mm2

50 mm

70 mm

150 mm2

12 mm (1)

18 mm (1)

22 mm (1)

6 Nm

10 Nm

10 Nm

Tightening torque
Nominal current (In) at 40 C (A)
In (A)

16

25

40

63

100

125

40

63

100

160

160

250

Phase

16

25

40

63

100

125

40

63

100

160

160

250

16

25

40

63

100

125

40

63

100

160

160

250

63

100

160

N/2
Magnetic threshold (Im) (A) (2)

Fixed

In (A)

16

25

40

63

100

125

40

63

100

160

160

250

Phase

480

625

800

950

1250

1250

400

630

1000

1600

1600

2500

480

625

800

950

1250

1250

400

630

1000

1600

1600

2500

950

N/2

1000

1600

(1) Copper bar only. (2) Trip current for 50/60Hz. For direct current, multiply by 1.5.

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

15

DPXTM 125
thermal magnetic MCCBs from 16 to 125 A

262 01
250 59
250 38

250 45 + 260 13

Dimensions (p. 22)


Electrical characteristics (p. 25)
MCCBs for switching, control isolation and protection of low voltage electrical lines
Can be fitted with auxiliaries (p. 20)
Can be used with earth leakage modules or with residual current relays (p. 21)
Supplied complete with:
- cage terminals 70 mm2 max.
- terminal shields
Conform to IEC 60947-2
Can be mounted on rail 2

Pack

Cat. No.

DPX-E 125 - fixed version

Pack

Cat. No.

Thermal release adjustable from 0.7 to 1 In and sealable


Fixed magnetic at 10 In in factory

Can be fitted onto DPX/DPX-I 125


Adjustable, sealable sensitivity:
0.03 - 0.3 - 1 - 3 A
Adjustable, tripping: 0 - 0.3 - 1 - 3 s
Test push-button
Reset push-button
Remote earth fault signalling contact
Switch for mechanical tests (installation insulation test)
230-500 V

Breaking capacity Icu 16 kA (230 V )


1P

1
1
1
1
1
1
1
1
1
1

In

250 00
250 01
250 02
250 03
250 04
250 05
250 06
250 07
250 08
250 09

16 A
20 A
25 A
32 A
40 A
50 A
63 A
80 A
100 A
125 A

Electronic earth leakage modules

Mounted side by side (at right-hand side)


3P

4P

260 02

260 03

63 A

In

260 12

260 13

125 A

262 01

Direct on DPX
Standard (grey)

262 75
262 76

Vari-depth handle IP 55
Comprising: connection rod, bracket, drilling template,
fixing accessories, door lock mechanism
Standard (grey)
For emergency use (red/yellow)

Rotary handles
DPX 125 - fixed version

Breaking capacity Icu 25 kA (400 V )


1
1
1
1
1
1

3P

4P

250 36
250 37
250 38
250 39
250 40
250 41

250 44
250 45
250 46
250 47
250 48
250 49

3P

4P

250 50
250 51
250 52
250 53
250 54
250 55

250 58
250 59
250 60
250 61
250 62
250 63

In

16 A
25 A
40 A
63 A
100 A
125 A

1
1

Accessories

Breaking capacity Icu 36 kA (400 V )


1
1
1
1
1
1

16

In

16 A
25 A
40 A
63 A
100 A
125 A

3P

262 05

Sealable terminal shields


Set of 2
Rear terminals
Used to connect fixed version
with front terminals into fixed
version with rear terminal

263 00

Set of upstream or downstream rear terminals

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DPXTM 160
thermal magnetic MCCBs from 40 to 160 A

262 11
251 72
251 25
251 33 + 260 21

Dimensions (p. 23)


Electrical characteristics (p. 25)
MCCBs for switching, control isolation and protection of low voltage electrical lines
Can be fitted with auxiliaries (p. 20)
Can be used with earth leakage modules or with residual current relays (p. 21)
Supplied complete with:
- connection plates for bars
- upstream and downstream connection devices for lugs (max. width 20 mm)
- terminal shields
Conform to IEC 60947-2
Can be mounted on rail 2
Pack

Fixed version

Cat. No.

Pack

Thermal adjustable from 0.64 to 1 In and sealable


Fixed magnetic at 10 In in factory

1
1
1

3P

4P

251 23
251 24
251 25

251 31
251 32
251 33

3P + N/2

Rotary handles

Cat. No.

Direct on DPX
1

262 11

Standard (grey)

Breaking capacity Icu 25 kA (400 V )

Vari-depth handle IP 55

In

Comprising: connecting rod, bracket,


drilling template, fixing accessories,
door lock mechanism

63 A
100 A
160 A

262 77

Standard (grey)

In

251 27

160 A

Accessories

Breaking capacity Icu 36 kA (400 V )


1
1
1

3P

4P

251 49
251 50
251 51

251 57
251 58
251 59

In

63 A
100 A
160 A

Breaking capacity Icu 50 kA (400 V )


1
1
1
1

3P

4P

251 62
251 63
251 64
251 65

251 70
251 71
251 72
251 73

In

40 A
63 A
100 A
160 A

3P

4P

262 15

262 16

262 18

262 19

262 17

Supply invertor type


1

Mounting plate
For mechanical interlocking of 2 DPX of the same
size for use in normal or automatic modes

264 01

3P

263 10

Sealable terminal shields


Set of 2
Cage terminals
Set of 4
For cable without lug 95 mm2 (rigid)
or 70 mm2 (flexible)
For cable without lug 120 mm2 (rigid)
or 95 mm2 (flexible)
Adaptator for lug
Set of 4 (upstream or downstream)
Supplied with insulated shield
Rear terminals
Used to connect a fixed version with front terminals into
fixed version with
rear terminals
Set of upstream and downstream rear terminals

Mounting accessories and common accessories (p. 19)


Electronic earth leakage modules
Can be fitted onto DPX/DPX-I 160
Adjustable, sealable sensitivity:
0.03 - 0.3 - 1 - 3 A
Adjustable, tripping: 0 - 0.3 - 1 - 3 s
Test push-button
Reset push-button
Remote earth fault signalling contact
Switch for mechanical tests (installation insulation test)
230-500 V

3P

4P

260 20

260 21

Mounted side by side (at right-hand side)


160 A

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

17

DPXTM 250 ER

High current chassis

thermal magnetic MCCBs from 100 to 250 A

For DPX 125 & DPX 250 ER, 630A, 415V, 50Hz rated chassis
tested at 36KA for 1s (76.6KA peak) in accordance with AS
3439-1:2002 clause 8.2.3

262 11

252 55

Dimensions (p. 24)


Electrical characteristics (p. 25)
MCCBs for switching, control isolation and protection of low voltage
electrical lines
Can be fitted with auxiliaries (p. 20)
Can be used with earth leakage modules or with residual current relays
(p. 21)
Supplied complete with:
- connection plates for bars
- upstream and downstream connection devices for lugs
(max. width 20 mm)
- terminal shields
Can be mounted on rail 2
Conform to IEC 60947-2
Pack

630A, 24-way high current chassis for DPX 250 ER

Fixed version

Cat. No.

Thermal adjustable from 0.64 to 1 In and sealable


Fixed magnetic at 10 In in factory

Breaking capacity Icu 36 kA (400 V )


1
1
1

3P

4P

252 24
252 25
252 26

252 34
252 35
252 36

3P

4P

252 44
252 45
252 46

252 54
252 55
252 56

In

100 A
160 A
250 A

Breaking capacity Icu 50 kA (400 V )


1
1
1

264 02

Pack

Cat. No.

630A, 24-way high current chassis with DPX 250 ER MCCBs

In

100 A
160 A
250 A

Pack

Cat. No.

High Current Chassis

Supply invertor type

608 241 12 way 630A DPX125


320 x 370 x 54mm

Mounting plate

For mechanical interlocking of 2 DPX of the same size for use


in normal or automatic modes

608 242 18 way 630A DPX125


396 x 370 x 54mm

608 243 24 way 630A DPX125


473 x 370 x 54mm

608 244 12 way 630A DPX250ER


345 x 470 x 54mm

608 245 18 way 630A DPX250ER


435 x 470 x 54mm

608 246 24 way 630A DPX250ER


526 x 470 x 54mm

Rotary handles

Direct on DPX
262 11 Standard (grey)

Vari-depth handle IP 55
Comprising: connecting rod, bracket,
drilling template, fixing accessories,
door lock mechanism
262 77 Standard (grey)

Accessories
3P

1
1

262 85

Cage terminals
262 88 (1) Set of 4
For cable without lug 185 mm2 (rigid) or 150 mm2 (flexible)
for DPX 250 ER and DPX-IS 250
262 90

Spreaders
Set of incoming or outgoing spreaders

265 10

Rear terminals
Used to convert the fixed version with front terminals
to the fixed version with rear terminals
Set of upstream and downstream rear terminals

3P

Sealable terminal shields


Set of 2

(1) Can not be mounted on side by side mounted earth leakage


modules 160 A

18

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DPXTM 125, 160 and 250 ER

DPXTM 125, 160 and 250 ER

mounting accessories

connection

Connection
DPX front terminals
Connection with cables

Connection with bars

048 67
DPX 125 160 250 ER
D
12 18
18

DPX 125 160 250 ER


max. 12 18
18

262 08

Mounting of distribution terminal

252 25 +
DPX250ERLK

048 68

Cat. No.

Fixing plates

Distribution terminal

For fixing devices on Din rail


262 08

For DPX 125

262 09

For DPX 160/250 ER

Insulated shields

160 A
47
6.5

250 A
12.5

60

26.5
10.5

16

6.5

10

30
17

10

25

Pack

262 00

Used to isolated the connection between


each pole
262 07

Set of 3

80

56

Insulated shields

Cat. No. 048 67

Distribution terminals
1

048 67

160 A - 6 outputs 25 mm2 flexible - Isc peak 30 k


Can be fitted directly onto downstream terminal of DPX 165/160,
Vistop 100/160 A and DX H 125 A

048 68

250 A - 4 outputs 35 mm2 flexible and 2 outputs


25 mm2 flexible- Isc peak 36 k
Can be fitted directly onto downstream terminal of
DPX 250/250 ER and DX-IS 250

Cat. No. 048 68

Padlocks
For locking in "off" position
1

262 00

For DPX 125

262 10

For DPX 160 and DPX 250 ER

1
1

DPX125LK For locking MCCB in on or off position


DPX250ERLK For locking MCCB in on or off position

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

19

DPXTM auxiliaries

DPXTM auxiliaries

Auxiliary contact or
fault signal
A single Cat. No. 261 60
auxiliary contact or fault signal

261 94

261 85

Pack

Cat. No.

261 60

Auxiliary contact or fault signal

Under-voltage releases

For signalling the state of the contacts


or opening of the MCCB on a fault
For DPX/DPX-I/DPX-IS
Changeover switch 3 A - 240 V

Releases
Allow remote tripping of a DPX
Shunt releases
For DPX-IS and DPX
Shunt inrush power 300 VA

261 64

261 67
For
DPX 125
DPX-IS
250, 630

For DPX 160,


250ER

Shunt releases

=
Coil voltage 230 V/=
Coil voltage 24 V /

Undervoltage releases

DPX-IS 800, For DPX-IS/DPX-I and DPX


1000, 1250, 1600

Undervoltage power consumption 5 VA

261 70

261 80

Coil voltage 24 V

261 71

261 81

Coil voltage 24 V

261 73

261 83

Coil voltage 230 V

Time-lag under-voltage releases

Max. number of contacts per DPX-IS device

Time-lag (ms) undervoltage releases


Allow remote tripping of a DPX
Prevent false tripping in the event of AC supply microbreaks
Require a time-lag module
connected to the undervoltage
releases below
Number of

261 90

Time-lag modules 230 V

261 75

Undervoltage releases
For DPX/DPX-I 125, DPX -IS 250,630

261 85

Undervoltage releases
For DPX/DPX-I 160, 250ER, and DPX -IS 1600

modules

Device

Auxiliary contact
AC
EBAC
FS

Shunt release
or undervoltage release

Without
release

DPX-IS 250

Without
release

DPX-IS 630

With
release

DPX-IS 1600

AC = auxiliary contact
EBAC = "early" auxiliary contact
FS = break on trip contact
Pack

Cat. No.

261 94

20

Automatic transfer switch controller

Max. number of contacts per DPX device


Auxiliary contact
AC
FS

Shunt release
or undervoltage release

Automatic transfer switch controller,


with RS485 ports and real time clock

Device

Size: 144 x 144 mm

DPX 125

Weight: 0.900 kg

DPX 160

DPX 250 ER

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

residual current relay and coils

residual current relay and coils

Residual current relay

NEW

Cat. No. 260 88

45

35

88

260 98

90

60
44

35

260 93 coil for use with relay

260 88

Add residual current protection to DPX trip-free switches and DPX MCCBs
equipped with release

Coils

M
D
5
E

Adjustable sensitivity: 0.03, 0.05, 0.075, 0.1, 0.15, 0.2, 0.3, 0.5, 0.75, 1,
1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A
- 110 to 210 mm

5.5

Adjustable sensitivity: 0.3, 0.5, 0.75, 1, 1.5, 2, 3, 5,


7.5, 10, 15, 20, 30 A
- 150 mm

Adjustable sensitivity: 1, 1.5, 2, 3, 5, 7.5, 10, 15,


20, 30 A


(KQ\Z[HISL[YPW!ZLJVUKZ

:\WWS`]VS[HNL!=/a

260 88

Number of
modules

Residual current relay to clip on rail 2

45 34

79

Adjustable sensitivity: 0.5, 0.75, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A


- 300 mm

L
C

 -VY\ZL^P[OJVPSZ!
- 35 and 80 mm

23

*VTWYPZLZ!
- a tinged, sealable window
- an auxiliary contact
- a green Led indicating energisation
- 3 yellow Leds indicating respectively the max. phase earth insulation
current: 20, 40 and 60 %
- a red Led indicating
Fixed: exceeding of the insulation fault current value
Flashing: breaking of one of the connections between coils and relays

Cat. No. 260 97

22

Cat. No. 260 92/93/94/95/96

Detects fault currents, and, when used with a shunt trip or an


undervoltage release, it gives the trip
command to a MCCB or a switch

Residual current relay

Cat. No.

Pack

Cat. No.
260 92
260 93
260 94
260 95
260 96
260 97

A
35
80
110
140
210
150

B
75
108
148
177
270
225

C
85
132
170
206
295
259

D
42
67
86
104
150
133

E
92
125
165
200
290
245

H
36
36
36
36
44
275

L
43
65
84
102
145
95

M
56
56
56
56
64
113

Cat. No. 260 98


7

Coils

21
5

260 92
260 93
260 94
260 95
260 96
260 97
260 98

58

1
1
1
1
1
1
1

For use with residual current relay Cat. No. 260 88


1 coil per DPX
Coil 35 mm
Coil 80 mm
Coil 110 mm
Coil 140 mm
Coil 210 mm
Coil 150 mm - open
Coil 300 mm - open

Viking 3 disconnector block for


measurement 1 connection
With its accessories, allows intervention (measurement, maintenance,
etc.) on a current, voltage and power measuring circuit by keeping the
current transformer secondary circuit closed
Colour

25

371 92

Grey

Nominal
cross
section
(mm2)
4

Capacity
Rigid
Flexible
wire
wire
2
(mm )
(mm2)
0.25 to 4

0.25 to 4

Pitch
(mm)

310

30

368
400

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

21

DPXTM 125

Dimensions
Rotary handle-direct on DPX

60

75.5

32

25.4

103

12.7

81
A

Terminal shields

A
DPX 125

170

DPX 125 + earth leakage module


mounted underneath

260

Fixed version, front terminals with earth leakage module mounted side by
side (1)
202
101

12.7
113.7

22

10

74

45

103

120

37.8

97
101
25.4

20
358.5 max.
173.5 min.(2)

0.8/2

62.5

(1) Dimensions of 3-pole earth leakage modules are the same as 4-pole earth leakage
modules
(2) 70 mm without mechanical system

39

10

74

M4

25.4

M8
M4

103

45
25.4

70

97
74

101

45

25.4 25.4

101

120

101

25.4

M4

Rotary handle-vari-depth on door


Mounting with flexible seal

Fixed version, rear terminals


75.6

48

40.2

80
M4

25.4

25.4

74

101

45

120

101

45

120

37.8

12

11.2

101

75.6
12

80

97
74

20

Fixed version, front terminals

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DPXTM 160

Dimensions

Rotary handle direct on DPX

Fixed version, front terminals

30
97
74

120

74

60
48
35

23

80

45

150

45

150

45

115
38.5 11.25

90

M4

1.5 max.

M4
30

18 max.

30

15
75.5

23

Fixed version, rear terminals


90

97

120

Rotary handle-vari-depth on door


Mounting with flexible seal
70

M4

74

30 30 30

74

358.5 max.
141.5 min.(2)

0.8/2

62.5

48

95

30 30

115

45

150

(1) Dimensions of 3-pole earth leakage modules are the same as 4-pole earth leakage
modules
(2) 70 mm without mechanical system

Fixed version, front terminals with earth leakage module mounted


side by side (1)
240

97
120

M4

60

132

150

86

95

30
==

74

45

Y
120

30

45
15

135
Y

Terminal shields

A
DPX 160

278

DPX 160 + earth leakage module


mounted underneath

393

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

23

DPXTM 250 ER

Dimensions

Terminal shields

Fixed version, front terminals

97
74

A
115
76.5

M4

max.
18

1.6

30 30 30

18

11.5

74

45

M4

20 max.

69

53.5

38.5

45

145
115

176

18

10 max.

120
30 30 30

90

97

mounted side by side

296

DPX 250 ER

Fixed version, front terminals with earth leakage module


(1)

Rotary handle-direct on DPX


250 A

30

M4

74

270
150

30

30

30

176

145

1.5 max
15
75.5

69

53.5

38.5

115

215.5

38.5

80

30

35

15

11.25

30

115

30

60
48

20 max.
30
30

30

Rotary handle-vari-depth on door


Mounting flexible seal

30

30
5

45

70

M4

74

358.5 max.
141.5 min.(2)

0.8/2

115

160 A

240

120

120

30
==

62.5

176

95

(1) Dimensions of 3-pole earth leakage modules are the same as 4-pole earth leakage
modules
(2) 70 mm without mechanical system

60

30

45
15

135
Y

24

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DPXTM
reading DPX characteristic curves and adjustment ranges
selection table DPXTM / DPXTM thermal-magnetic
Tripping curve for a DPX thermal-magnetic

Adjustment for thermal-magnetic DPX


Setting

10 000

Ir overload
trip threshold
(thermal)
Im short-circuit
trip threshold
(magnetic)

t (s)
Thermal realease zone
when cold

1 000

DPX 125

DPX 160
DPX 250 ER

0.7 to 1 In

0.64 to 1 In

fixed: 10 In
(100 and
125 rating)

fixed: 10 In

100

10

Thermal realease zone


when hot

1
Adjustable magnetic
realease zone
0.1

Im

0.01

0.001

3 4 5

10

20

30

50

100
I/Ir

I: actual current
Ir: thermal protection against overloads (setting: Ir = x In)
Im: magnetic protection against short-circuits (setting: Im = x In or Im = x Ir)
As the abscissa of the curves represents the ratio I/Ir, modifying the setting of Ir will not
change the graphical representation of the thermal trip. However, the magnetic setting
can be read directly (between 3.5 and 10 in the example).

Limits of selectivity (three phase circuit at 400 V)


Upstream MCCB
DPX 125 (16 kA)
DPX
DPX 125 (25 kA)
Downstream MCCB
DPX 125 (36 kA)
In (A)
40
63
100
DPX
Ist. (kA) 0.8
0.95
1.25
16
0.8
1
1.2
25
0.8
1
1.2
40
1
1.2
DPX 125 (16 kA)
63
1.2
100
125
16
0.8
1
1.2
25
0.8
1
1.2
40
1
1.2
DPX 125 (25 kA)
63
1.2
100
125
16
0.8
1
1.2
25
0.8
1
1.2
40
1
1.2
DPX 125 (36 kA)
63
1.2
100
125
63
DPX 160
100
DPX 250ER
160
(25 kA)
250
63
DPX 160
100
DPX 250ER
160
(36 kA)
250
40
63
DPX 160
DPX 250ER
100
(50 kA)
160
250

125
1.25
1.2
1.2
1.2
1.2

1.2
1.2
1.2
1.2

1.2
1.2
1.2
1.2

DPX 160 (25 kA) DPX 250ER (25 kA)


DPX 160 (36 kA) DPX 250ER (36 kA)
DPX 160 (50 kA) DPX 250ER (50 kA)
63
100
160
250
0.63
1
1.6
2.5
0.63
1
1.6
2.5
1
1.6
2.5
1
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
0.63
1
1.6
2.5
1
1.6
2.5
1
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
0.63
1
1.6
2.5
1
1.6
2.5
1
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1
1.6
2.5
1.6
2.5
2.5

0.63

1.6
1.6

2.5
2.5
2.5

1
1

1.6
1.6
1.6

2.5
2.5
2.5
2.5

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

25

association and coordination information

Association and co-ordination of MCCBs (in kA)

In 3 phase networks + N 400/415 V according to IEC 60947-2


DPX 125
25 kA

DPX 125
36 kA

25

DPX-E 125
DPX 125 (1)

DPX 250 ER
36 kA

36

36

36

36

DPX 125 (2)


DPX 250 ER (2)
DPX 250 ER (3)
(1) 25 kA Icu (2) 36 kA Icu (3) 50 kA Icu

Association and co-ordination of MCCBs and MCBs (in kA)


In 3 phase networks 400 V according to IEC 60947-2
MCBs/MCCBs upstream
DX-H 10 kA
B and C curves

DX-H
10 kA
B and C (1)
curves

DPX 250 ER

2 to
32 A

40 to
63 A

16 to
125 A

16 to
125 A

63 A

1 to 20 A

25

125

16

25

25 A

25

125

16

25

32 A

125

16

40 A

125

100 A

160 A

250 A

25

25

25

25

25

25

25

25

25

25

25

25

25

16

25

25

25

25

25

50 A

16

25

25

63 A

16

25

1 to 16 A

16

25

20 A

16

25

25 A

16

32 A

MCBs downstream

DX-E 6 kA
DX-D
D (1) curve

DPX E DPX 125


125

25

20

20

20

15

15

25

25

25

25

25

25

25

25

25

25

25

25

25

16

25

25

25

25

25

40 A

16

25

25

25

25

25

50 A

16

25

25

25

20

20

63 A

16

25

25

20

15

15
20

80 A

20

20

100 A

20

20

20

15

15

125 A

(1) The magnetic threshold of the upstream circuit breaker must be higher than the magnetic threshold of the downstream circuit breaker

Association and co-ordination of MCCBs and MCBs (in kA)


In 3 phase networks + N 230/240 V according to IEC 60947-2
MCBs/MCCBs upstream
DX-H 10 kA
B and C curves
2 to
MCBs downstream
32 A
1 to 25 A
32 & 40 A
DX-E 6 kA
DX-D
D(1) curve

50 A

40 to
63 A
50

16 to
125 A

DPX-E
125
16 to
125 A

DPX 125

DPX 250 ER

63 A

100 A

160 A

250 A

25

22

35

50

50

50

25

22

35

50

50

50

50

16

25

36

36

36

36

63 A

16

25

30

30

30

80 A

16

25

25

25

25

100 A

16

25

125 A
DX-H
10 kA
B and C(1)
curves

50

25

25

25

25

1 to 40 A

22

35

50

50

50

50

50 A

16

25

36

36

36

36

63 A

16

25

30

30

30

(1) The magnetic threshold of the upstream circuit breaker must be higher than the magnetic threshold of the downstream circuit breaker

TT or TNS neutral earthing systems : For a 230/400 V supply in order to determine the breaking capacity of a 2 P MCB used as L + N (230 V) downstream a 2 P or 4 P circuit breaker use values indicated in the table for 230/240 V
Note: selectivity table - MCCBs (see previous page)

26

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DX-E, DX, DX-H, DX-D MCBs

Technical information

Maximum voltage: 240 V - 415 V


~10 %
Maximum voltage: 80 V per pole
Insulation voltage: 500 V
Dielectric: 2 500 V

Power dissipated in W per pole at In


In A

10

16

20

25

32

40

50

63

80

100

Type B

21

21

24

25

11

11

15

17

24

31

45

55

125
-

Type C

21

21

24

25

11

11

15

17

24

31

45

55

88

78

156

Type D

21

21

24

25

11

11

15

17

24

31

45

55

88

78

156

Mechanical characteristics
Endurance: 20 000 mechanical switching operations
10 000 on load switching operations at In x cos 09

Connection cross-sections (in mm )

In ) 63 A

In * 80 A

25 mm2 flexible cables


35 mm2 rigid cables

50 mm2 flexible cable


70 mm2 rigid cable

25 Nm

3 Nm

Applied connection torque

Derating according to ambient temperature (In A)

In at 30 C

0 C

10 C

20 C

Ambient temperature
30 C
40 C

50 C

60 C

1
2

11
22

107
21

103
206

1
2

097
194

093
186

090
180

3
4
6

33
44
66

32
42
64

31
41
62

3
4
6

29
39
58

28
38
55

26
36
54

10

11

107

103

10

97

93

90

16
20

18
224

173
216

166
208

16
20

154
192

147
184

141
176

25
32

283
362

272
349

26
333

25
32

24
307

227
291

217
278

40
50

46
575

44
55

42
525

40
50

38
475

36
45

34
425

63
80

731
91

699
88

661
84

63
80

598
76

561
72

529
69

100

114

110

105

100

95

90

86

125

142

137

131

125

119

113

108

Technical information
Derating of MCBs according to the number of adjacent MCBs
Number of adjacent MCBs
Coefficient

from 1 to 3

from 4 to 6

from 7 to 9

over 10

08

07

06

MCB supplementary data (6 kA and 10 kA)


Terminal depth : 14 mm
Terminals protected to IP 20
Maximum terminal torque : 3 Nm
(recommended : 25 Nm)
Average weight per pole : 0160 kg
Supply : can be supplied from the top or bottom
Padlockable in either ON or OFF position
Operation with DC volt supply : up to a maximum of 80 V DC per pole for voltages
above 80 V DC use multipole devices wired IN SERIES (e.g. two pole 160 V= maximum)
Positive contact indication in accordance with the IEE 16th Edition Wiring Regulations

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

27

electrical energy metering on door

146 65
146 61

Pack

047 79

Cat. No.

Analogue metering devices - panel mounting

Pack

Cat. No.

Used with ammeters, electricity meters and central measuring units


Supply a current of 0 to 5 A to the secondary which is proportional to the
primary current
Can be fixed on plate, on rail 4
EN 60715, on bars
Secondary joining with terminals for lugs, cage terminals
Precision class: 1 %

Ammeters
Measure the intensity in amperes (A) of the current
Connected via a 0 - 5 A output current transformer (CT)
To be fitted with a measuring dial appropriate for the current to be
measured
1

146 01

Square barrel 68 x 68 mm
Measuring dial for ammeters

046 31
046 34
046 36

Single phase CT for bar 16 x 12.5 mm


and cable 21 mm
Transformation ratio Power (VA)
50/5
1.25
100/5
2.5
200/5
5.5

047 75

Single phase CT for bar 20.5 x 12.5


and 30 x 10.5 mm and cable 23 mm
300/5
11

046 38

Single phase CT for bar 40.5 x 10.5 mm


and cable 35 mm
400/5
12

1
1
1

047 76
047 77
047 78

Single phase CT for bar 65 x 32 mm


600/5
12
800/5
15
1000/5
20

047 79

Single phase CT for bar 84 x 34 mm


1250/5
15

1
1

046 45
046 46

Single phase CT for bar 127 x 38 mm


1500/5
15
2000/5
20

1
1

047 80
046 48

Single phase CT for bar 127 x 54 mm


2500/5
50
4000/5
50

Supplied by set of 2 (1 for round barrel, 1 for square barrel)


1

146 10

0 - 50 A

146 13

0 - 100 A

146 15

0 - 200 A

146 16

0 - 250 A

146 17

0 - 300 A

146 18

0 - 400 A

146 20

0 - 600 A

146 21

0 - 800 A

146 22

0 - 1000 A

146 66

0 - 1250 A

146 24

0 - 1500 A

146 25

0 - 2000 A

146 26

0 - 2500 A

146 28

1
1
1

0 - 4000 A
Voltmeters
Measure the voltage in volts (V) AC ou DC
Scale: 0 - 500 V

146 61

Square barrel 68 x 68 mm

Digital central measuring units


Enables via a 0 - 5 A output current transformer (CT), measuring electrical
values for low voltage applications

Current transformers (CT)

Multi-function centrals
For measuring: current and voltage per phase, frequency, power factor,
active and reactive energy
Adapts to 3-phase balanced or unbalanced supplies with or without
neutral
Max. measurement: 8000 A
220 V
1

146 65

Standard

146 67

Communicating Modbus/JBUS
Data speed transmission: 1200 to 9600 Bauds

28

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

electrical energy metering on door

Analogue metering devices

Current transformer

Frequency: 50/60 Hz
Precision class: 1.5 %
Operating temperature: - 10 C to + 40 C
Storage temperature: - 20 C to + 80 C
Consumption:
ammeter: 1.1 VA
voltmeter: 3 VA
Connection capacity: 2 x 2.5 mm2 with screws or
Conform to IEC 60051, VDE 0410, BS 89,
EN 60051-1, cenelec HD 223

Degree of protection: IP 20
Frequency: 50/60 Hz
Dimensions

Opening
for bar
width x th. (mm)

Fixing center
for fixing on
plate (mm)

50/5
100/5
200/5

21

16 x 12.5

on rail EN 50022

CT 300/5

23

20.5 x 12.5
25.5 x 11.5
30.5 x 10.5

50 x 45

CT 400/5

35

40.5 x 10.5

54 x 45

CT 600/5
800/5
1000/5

65 x 32

fix on bar

CT 1250/5

84 x 34

fix on bar

CT 1500/5
CT 2000/5

127 x 38

fix on bar

CT 2500/5
4000/5

127 x 54

fix on bar

Single phase CT

CT

Cat. No. 146 01/61


A
E

Opening
for cable
max. (mm)

A
E

400

Dimensions (mm)
B
C
D

72

66.5

44

12

680,7

Digital central measuring units


7YLJPZPVUJSHZZ!
voltage: 0.5 %
current: 0.5 %
power: 1.5 %
power factor: 2 %
frequency: 0.15 Hz
Active energy: class 2
Reactive energy: class 3

*VUZ\TW[PVU!
voltage: 0.5 VA / phase
current: 0.75 VA / phase
(\_PSPHY`WV^LYZ\WWS`!
single-phase voltage 230 V (196 to 253 V)
frequency 50 Hz (47 to 63 Hz)
self consumption 6 VA - 3.5 W

A
E

A
E

A
96x96

Dimensions (mm)
B
C
D
90x90

Output:
Energy pulse duration = 100 ms via volt free contact:
- for 5 A, 1 pulse/Wh
- from 20 to 150 A, 1 pulse/10 Wh
- from 200 to 1600 A, 1 pulse/100 Wh
- from 2000 to 8000 A, 1 pulse/kWh
Breaking capacity 110 V / - 50 mA
4-wire connection - 3 CT:

64.5

20

E
92x92

Input

2 5 8 11 1

Output

Supply

12 13

20 21

L1
L2
L3
N

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

29

electrical energy metering on rail 4

046 81

046 72

046 74

046 65

Dimensions (p. 33)


Measure the electrical energy consumed by a single phase or
3-phase circuit downstream of the metering of energy distributor
Provide a clear display of the consumption in kWh
Class I precision for energy active for Cat. No. 046 73 and 046 74 in
accordance with IEC 62053-21/23
Class II precision for energy active for Cat. No. 046 81 and 046 72
in accordance with IEC 62053-21/23 (with a sealable box)
Pack

Cat. No.

Single phase meters


Direct connection
Power supply: 230 V

- 50/60 Hz

Without pulse transmitter


1

046 81

Up to 32 A
Display: LCD screens
6 digits including 1 decimal place
1 unit = 0.1 kWh
Partial counting with reset

Pack

Number
of modules

1
1

With pulse transmitter


1

046 72

Up to 63 A
Display: LCD screen
6 digits including 1 decimal place
1 unit: 0.1 kWh
Partial counting with reset
With pulse transmitter to feed back remote
electronical energy consumption pulse
output: 1 imp/10 Wh

Technical characteristics

Display: LCD screen


8 digits, 1 unit: 0.01 kWh
With pulse transmitter to feed back remote electrical energy consumption
measurements via volt-free contact
Partial counting with reset

046 73

Number
of modules

Up to 63 A per phase

Power supply:
- 230 V - 50/60 Hz (3 phase)
- 400 V - 50/60 Hz (3 phase + N)
Programmable pulse output:
1 x 200 ms pulse every 1 kWh (default value)

30

046 74

Power supply:
- 230 V - 50/60 Hz (3 phase + N)
- 400 V - 50/60 Hz (3 phase + N)
Programmable pulse output:
1 x 200 ms pulse every 1 kWh (default value)
Current transformation ratio:
50/5 to 8000/5

Display:
3 green LED displays with manual selection:
- Current per phase
- Phase-to-phase voltage
- Phase voltage
- Instantaneous power: active, reactive and apparent
- Frequency and power factor (inductive/capacitive indication)
- Active energy
Unit of measurement: display according to the CT ratios
Automatic change of rating
Energy metering: totalising 9 digits in kWh, resolution 10 Wh
Input:
Voltage measurement consumption < 1 VA per phase
Current measurement consumption < 0.5 VA per phase
Auxiliary power supply:
Voltage 230 V single phase (+/- 10%)
Frequency 50 Hz (47 to 63 Hz)
Consumption < 6 VA - 3.5 W

Connection via a 0 - 5 A
current transformer (CT)
1

Central measuring units

Multi-function centrals
Measure via a 0 - 5 A output current transformer (CT),
electrical values for low voltage applications:
For measuring current per phase, phase-to-phase voltage,
frequency, power factor, instantaneous power (active, reactive, apparent),
active and reactive energy
Adapt to 3-phase balanced or unbalanced supplies
with or without neutral
220 V - max. measurement: 8000 A
046 65 Standard
046 67 Communicating Modbus/JBUS
Data speed transmission: 1200 to 9600 Bauds

Q Multi-function central unit

3-phase meters

Direct connection

Cat. No.

Output:
Energy pulse: duration > 100 ms
Via volt free contact
Connection
3 or 4-wire connection - 3 CT

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

isolating switches
selection chart

VISTOP VISIBLE LOAD BREAK SWITCHES


Black handle
Rating (A)

Front handle

63

Side handle

3P

4P

3P

4P

225 12

225 15

225 16

225 18

100

225 20

225 22

225 25

225 27

125

225 34

225 39

225 44

225 46

160

225 51

225 53

225 54

225 56

DPX-IS VISIBLE LOAD BREAK SWITCHES


Without release
Rating (A)

Front handle

3P

4P

Right-hand

Left-hand

side handle

side handle

3P

4P

266 12

3P

4P

160

266 02

266 22

250

266 03

266 07

266 13

266 17

266 23

266 27

400

266 60

266 62

266 64

266 66

266 68

266 70

630

266 61

266 63

266 65

266 67

266 69

266 71

800

265 91

265 95

with release

1 000

265 92

265 96

with release

1 250

265 93

265 97

with release

1 600

265 94

265 98

with release

DPX-I TRIP-FREE SWITCHES


Rating (A)

Devices

3P

125

DPX-I 125

250 98

160

DPX-I 160

251 98

250

DPX-I 250 ER

252 98

250

DPX-I 250

253 98

400

DPX-I 630

255 86

630

DPX-I 630

255 88

800

DPX-I 1 600

257 94

1 250

DPX-I 1 600

257 96

1 600

DPX-I 1 600

257 98

DX-IS ISOLATING SWITCHES


Without release
Rating (A)

2P
043 21

3P

16

1P
043 01

20

043 02

043 22

043 42

043 62

32

043 05

043 25

043 45

043 65

40

043 07

043 27

043 47

043 67

63

043 10

043 30

043 50

043 70

100

043 14

043 34

043 54

043 74

043 38

043 58

043 78

125

4P

DX-IS

VISTOP

DPX-IS

Isolation with positive contact indication


from 16 to 125 A
Tripping version (common DX auxiliaries)
Red handle: main device
Faulty contact indicator
Fixing on rail

Isolation with visible contact indication


from 63 to 160 A
Fixing on
rail or on plate
External reversible side handle or front
handle

Isolation with visible contact indication


from 160 to 1 600 A
Fixing on 2 rail or on plate up to 250 A.
Above 250 A, fix on plate
Tripping version (common DPX
auxiliaries)

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

31

DPX-I 125 to 1 600 A

VistopTM 63 to 160 A

trip-free switches

visible load break isolating switches, screws or


din-rail mounting

225 15

255 88

250 98

Conform to IEC 60947-3


Category of use AC 23 A
Can be associated to earth leakage modules or to corresponding DPX
residual current relays
Mount on rail 2 up to DPX 250 ER
Connection identical to corresponding DPX
Pack

Cat.No

DPX-I 125
In

3P
250 98

In

3P
251 98

125 A

DPX-I 250 ER
160 A

3P
252 96
252 98

Pack

Cat. No.
Front
handle

Side
handle

3P
255 86
255 88

1
1

3P
257 96
257 98

No of 17.5 mm
modules

1/10

225 12

225 16

3-pole

160 A
250 A

1/10

225 15

225 18

4-pole

1/10

225 20

225 25

3-pole

7.5

1/10

225 22

225 27

4-pole

100 A

In

250 A

125 A
1/10

225 34

225 44

3-pole

7.5

1/10

225 39

225 46

4-pole

DPX-I 630
1
1

Black handle
63 A

In

DPX-I 250
3P
253 98

225 18

Safety isolating switches with visible breaking of load and positive action of
the contacts
Double breaking of the phases by self-cleaning snap open/close action
contacts
Label holders for identification of the circuits
Connection via cage terminals tightened by Allen key (except 63 A ; by PZ 2
screws)
Screw-fixing or on EN 50022 4 rail (only on rail for 63 A Vistop)
Two versions for mounting on faceplate:
>P[OSLM[VYYPNO[L_[LYUHSZPKLOHUKSL^P[OZLHS[VTHPU[HPU[OL07WYV[LJ[PVU
(up to IP 55), mounting accessories, self-adhesive drilling template,
adjustable extension rod (30 to 170 mm)
>P[OKPYLJ[VYL_[LYUHSMYVU[OHUKSL^P[O*H[5V[VILVYKLYLK
separately
Possibility of attaching a 2-pole - 16 A auxiliary isolating switch Cat. No. 227 22,
or one or two N/C + N/O auxiliary Cat. No. 227 04/07

DPX-I 250 ER
1
1

In
400 A
630 A

DPX-I 1 600
In

1 250 A
1 600 A

4 rail xing

160 A
1/10

225 51

225 54

3-pole

7.5

1/10

225 53

225 56

4-pole

Vistop accessories
TM

for load break isolating switches Up to 160A

Pack

Cat. No.

Auxiliary contacts
Set of 2 auxiliary switches for
on/off signalling 5A/250V

1/100

227 04

Single pole auxiliary from 63A to 160A (1NO + 1NC)

1/100

227 07

Additional contact from 63A to 160A (2NO + 2NC)

Door interlock facilities


Extension shaft door interlock (1)
1/10

227 32

For 63/100/125A /160 Vistop

50

227 98

Set of 2 separate, sealable terminal shields

Sealable terminal shields


Clip on upstream and/or downstream of
Vistop 100 to 160 A
1/50

32

227 22

2P 16A Contact (Switch module) for Vistop


100/125/160A

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

Vistop 63 to 160 A
TM

isolating switch

2 rail mounting

Conform to standards NF C 63-130, NF EN 60947-3, IEC 60947-3, BS


EN 60947-3, VDE 0660, NBN EN 60947-3,

Electrical characteristics

CNOMO E03 - 15-611 R, Veritas approved

Thermal rating (Ith)

Version with red handle/yellow front plate conforms to standards


NF C 79-130, VDE 0113, IEC 60204-I, EN 60204
Glass fibre reinforced insulating casing, self-extinguishing at 960 C (IEC
NF EN 60695-2-1)
Handle can be padlocked in open position using 1-3 padlocks 6 mm
VistopTM 63 to 160 A - visible contact indication
Accept auxiliary contacts N/C + N/O (cat. No 227 04/07) 1 or 2 (side
handle)
Front handle

78
C 2
83
63
45

22
6
C

44
m in . 1 1 4 - m a x . 5 2 3

32

24

C1

Short circuit capacity


(kA prospective peak)
(Icm)
Mechanical
endurance
(No of operations)

22,5

C2
83
66
63
45

Index of Protection

22
44
60

C
C1
C2

C1

C1

C1
C

Front handle
63 A
100 A, 125 A, 160 A
3 and 4-pole
3P
4P
125
133
160
17.7
26.7
90
91

16
50

100 A

cage

cage

4 to 352
4 to 502

Insulating voltage
690 V
(Ui)
Impulse resistant
8 kV
voltage (U imp)
400 V 63 A (35 kW)
AC 22 A
500 V 63 A (44 kW)
AC 23 A (1)
690 V 40 A (38 kW)
DC 22 A/250 V (1) (2)*
63
63
DC 23 A/250 V (1) (2)*
Breaking capacity
(Icu) (kA peak)
1 s resistant
current (kA rms) (Icw)
Icc
with fuses
(kA rms)
Fuse rupture
capacity

98
74
60

C 1

Terminals
Connec- Cu(flexible)
tion
Cu (rigid)

63 A

800 V

8 kV
100 A (55 kW)
100 A (69 kW)
100 A (96 kW)
125
125

125 A

160 A

switch
16 A (4)

cage

cage

cage

4 to 50 mm2
4 to 70 mm2

800 V

800 V

8 kV

8 kV

125 A (70 kW) 160 A (88 kW)


125 A (87 kW) 160 A (110 kW)
125 A (120 kW) 125 A (120 kW)
125
16 A
125
10 A

62
62

400 V
-

16 A
-

15

15

15

15

2,5

3,5

3,5

3,5

100

100

100

80

100

63 A

100 A (gG)
63 A (aM) (3)

125 A (gG)
125 A (aM) (3)

160 A (gG)
125 A (aM)

12

12

12

> 30 000

> 30 000

> 30 000

> 30 000

> 30 000

IP 2x B
(IP 3x C under
frontplates)

IP 2x B (IP 3x C under frontplate) from 10 mm2

(1) Test conditions accordance with IEC 60947-3


AC = alternating current. DC = direct current. A = for frequent switching
AC 22 A/DC 22 A : resistive motor breaking
AC 23 A/DC 23 A : inductive motor breaking
(2) N of breaking contacts: 2
(3) 100 A (aM) with blade type cartridge fuses
(4) Values correspond to the device mounted on Vistop 100 - 125 - 160 A

External side handle


63 A
100 A, 125 A, 160 A
3 and 4-pole
3P
4P
125
133
160
17.7
26.7
90
91

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

33

DPXTM-IS 250 isolating switches


160 to 250 A

266 07

266 17

262 39

Isolating switches for on-load circuit breaking by visible isolation and positive action of the contacts
Padlock integrated in the handle
Connection with cage terminals
Supplied with terminal shields
Conform to IEC 60947-3
Category of use AC 23 A
Accept the same electrical auxiliaries as the DPX (p. 20)

Pack

Cat. No.
3P

4P

1
1

266 02
266 03

1
1

266 12
266 13

1
1

266 22
266 23

DPX-IS without release

Pack

Rotary handles

Cat. No.

Front handle

Vari-depth handle IP 55

160 A
266 07 250 A

Comprising: connecting rod, bracket, self-adhesive


drilling template, fixing accessories (seal to maintain the IP
protection up to IP 55, door lock mechanism)

Right-hand side handle


1

160 A
266 17 250 A

266 86

For front and side handle device

Accessories

Left-hand side handle


160 A
266 27 250 A

Cage terminals

Mounting on rail
262 39

262 88 (1)

273 22

Set of 4
For cable 185 mm2 (rigid) or 150 mm2 (flexible) for DPX 250
ER and DPX-IS 250

Rail 4 fixing plate


1

For mounting DPX-IS 250

Spreaders
Set of upstream and downstream spreaders
Rear terminals
Used to convert the fixed version with front terminals to the
fixed version with rear terminals
3P

4P

265 10

265 11 Set of upstream and downstream terminals


Terminal shields

262 87

Set of 2

262 99

Rail height spacer fits on Din Rail used to mount on the


same row DX and DPX/DPX-IS
(1) Can not be mounted on side by side mounted earth
leakage modules 160 A

34

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DPXTM-IS 250 isolating switches

Electrical characteristics

Mounted on rail Din


72.5

160 A
150 mm
185 mm2
Width max. 28 mm
690 V - 250 V
800 V

Copper bar
Nominal rating (Ue)
Rated insulation voltage (Ui)

11.5

160 A
160 A
160 A

Short-circuit making capacity


(kA efficient)
(Icm)
I admissible ls (Icw)
I admissible with fuse (Icc)
gG
160 A
Max. rating of fuse
aM
Rated closing capacity
on short circuit (kA peak)

8.5

250 A
160 A
250 A

1
75
76.5

195

40 kA

With terminal shields

12 kA efficient
100 kA efficient
250 A
160 A

105

72.5

85.5

70

160 A

74

35

40 kA

42

138

2500 operations

258

25000 operations

mechanical
electrical
(AC 23 - 400 V)
Index of protection

Endurance

45

11.5

(Icm)

129

60

AC 22 A

138
35

8 kV

400 V
690 V
690 V

AC 23 A

74
40.5

Rated impulse withstand


voltage (Uimp)

105
70
35

45
42

Cu flexible
Cu rigid / Alu

Connection

250 A
2

27

Rating

IP 20 front panel
40.5

Dimensions
Front handle

45

1.5
28
max.

1-6
74

Mounting
Mounted on rail with plate

11.5

18

35 35 35
160
195

55
195

50 min. 32
300 max.
11.5

42

M4

18
8

74

77
45

10 max.

18 max.

10 max.
M4

138
77

17.5

140

90
35 35 35

Spacer
262 99

40.4

Right lateral handle

90

227
195
35 35 35

45

77

42

138
107

132

M4

74

17.5

Plate 262 39

35 35 35

162

Distribution terminal
048 68

Left lateral handle


227
195
35 35 35

42

77

45

107
138

132

M4

90

35 35 35

17.5

74
162

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

35

DPXTM-IS 630 isolating switches


400 to 630 A

266 70
262 50
266 62

Isolating switches for on-load circuit breaking by visible isolation and positive action of the contacts
Padlock integrated in the handle
Supplied with terminal shields, and cage terminals
Conform to IEC 60947-3
Category of use AC 23 A
Accept the same electrical auxiliaries as the DPX (p. 20)

Pack

1
1

Cat. No.
3P

4P

266 60
266 61

266 62
266 63

DPX-IS without release

Pack

Cat. No.

262 50

Cage terminals

Front handle
400 A
630 A
Right-hand side handle

1
1

266 64
266 65

266 66
266 67

Accessories

400 A
630 A

Set of 4 terminals for cable 300 mm2 max.(rigid) or 240 mm2


max.(flexible)

3P

4P

262 48

262 49

266 68
266 69

266 70
266 71

400 A
630 A

Used to convert the fixed version with front terminals to the


fixed version with rear
1

263 50

263 51

263 52

263 53

Rotary handles

36

266 86

Set of incoming or outgoing spreaders


Rear terminals

Left-hand side handle


1
1

Spreaders

Set of incoming and outgoing swivel rear terminals


Set of incoming and outgoing flat rear terminals
Sealable terminal shields

Comprising: connecting rod, bracket, self-adhesive


drilling template, fixing accessories (seal to maintain the IP
protection up to IP 55, door lock mechanism)

For front and side handle device

262 45

Set of 2
Padlock
For locking mechanism in open position

266 97

Ronis

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DPX-ISTM 630

Technical characteristics

Left lateral handle


400 A

630 A
cage

43.5 43.5

48.1

17

M5

630
630
400
630

A
A
A
A

20 kA RMS

43.5 43.5 43.5

42

A
A
A
A

94
1 38
160
200

8 kV ac
400
400
400
400

26.4

105

100 kA

181

400 A
400 A

630 A
630 A

Front handle with terminal shields

40 kA
15 000 operations
1 500 operations

1 3 0 .5
87
4 3 .5

1 0 8 .2

IP 20 front panel

48.1

43.5 43.5

105
0

90

1 6 5 .3

38.2

28

11

17

3 8 .7

26.4

42

15 max.
M5

200

138

1 8 3 .2

25 max.
43.5

43.5

94

Front handle

42

200

Dimensions

32 max.

132

90

Copper bar
Nominal Rating (Ue)
Rated insulation voltage (Ui)
Rated impulse withstand
voltage (Uimp)
400 V ac
AC 23 A
500 V ac
690 V ac
AC 22 A
690 V ac
I admissible ls (Icw)
I admissible with fuse
(kA efficient) (Icc)
Max. rating of fuse gG
Max. rating of fuse aM
Short-circuit
making capacity (kA efficient)
(Icm)
Mechanical endurance
Electrical endurance
(AC 23 400 V ac)
Index of protection

265

6 5 .3

Connection

297.4

1 x 240 or 2 x 185 mm2


1 x 240 or 2 x 185 mm2
Width max 32 mm
690 V ac
800 V ac

Cu flexible
Cu rigid

3 3 0 .6

Rating
Terminals

8 1 .8

265

105
116

11

28

43.5
265

Right lateral handle

297.4
265
48.1

17

43.5 43.5

42

200
160
138
94

M5

132

90

105

26.4

43.5

43.5

43.5

181

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

37

DPX-IS 1 600 isolating switches

DPX-IS 1 600 isolating switches

800 to 1 600 A
accessories
Electrical characteristics
Rating

800 A

Connection

1 000 A

2 x 240 mm2 or 4 x 240 mm2

Alu

2 x 240 mm2 or 4 x 240 mm2


50 mm or 80 mm

Nominal rating (Ue)

690 V

Rated insulation voltage (Ui)

690 V

Rated impulse
withstand voltage (Uimp)

8 kV

262 65

Isolating switches for on-load circuit breaking by visible isolation


and positive action of the contacts
Connection with cage terminals
Padlock integrated in the handle
Supplied with terminal shields
Conform to IEC 60947-3
Category of use AC 23 A
Pack

DPX-IS with release

Cat. No.

3P

4P

Supplied without shunt release


Can be associated with a residual current relay with separate
coil
Front handle

265 91

800 A

265 92

1 000 A

265 93

265 97 1 250 A

265 94

265 98 1 600 A

1 600 A

Cu rigide

Copper bar

265 98

1 250 A

2 x 185 mm2 or 4 x 185 mm2

Cu flexible

400 V

800 A

1 000 A

1 250 A

1 600 A

AC 23 A

500 V

800 A

1 000 A

1 250 A

1 600 A

690 V

800 A

1 000 A

1 250 A

1 600 A

DC 23 A

250 V

800 A

1 000 A

1 250 A

1 600 A

20 kA RMS

I admissible is for 1s (Icw)

100 kA RMS

I admissible with fuse (Icc)


800 A

Max. rating of fuse

1 000 A

1 250 A

Short-circuit making capacity


(kA peak) (Icm)

40 kA

Mechanical endurance

10 000

Electrical endurance
(AC 23 A - 400 V)

3 000

3 000

2 000

1 600 A

2 000

IP 20 front panel

Index of protection

Dimensions
Front handle with terminal shields

Mounting accessories

262 70

Set of 1 terminal for cables


2 x 240 mm2 max. (rigid)
or 2 x 185 mm2 max. (flexible)
Set of terminal for cables
4 x 240 mm2 max. (rigid)
or 4 x 185 mm2 max. (flexible)
Spreaders

3P

4P

262 73

262 74

1
1

263 80
263 81

263 82

1
1

262 67
262 68

25
50

For increasing the distance between each


pole to be connected
Set of upstream or downstream spreaders
Rear terminals
Set of 6 (or 8) rear terminals, upstream or
Short terminals
Long terminals
Extended front terminals

158

35
140
210

M12
M10

Terminal shields
downstream

Short terminals
Long terminals

Common auxiliaries to DPX (p. 20)

38

94

24 max.

Cage terminals
262 69

205
100

298

320

Connection accessories
1

64

278

Used to isolate the connections between each pole


Set of 3 insulation shields

262 66

70

Set of 2 short terminal shields


Insulation shields
169

204

70

320

262 65

70

42

262 64

280

Sealable terminal shields

149

4P

280

3P

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

140

proximity switching 63 to 160 A


IP65

proximity switching 63 to 160 A

Full load switch units 63 to 160 A


Electrical characteristics
Identical to corresponding Vistop isolating switch
Switch units

Cat. No.

63 A

226 15/17

Vistop 63 A p. 118

Characteristics

100 A

226 25/27

Vistop 100 A p. 118

125 A

226 33/34

Vistop 125 A p. 118

160 A

226 35/37

Vistop 160 A p. 118

Dimensions
E

226 37

226 17

For on-load circuit breaking, isolation and locking in 0 position equipment


located remotely
Applications:
IYLHRPUNVM*4=JVU[YVSSLKTLJOHUPJHS]LU[PSH[PVUTV[VYZMP_LKVY
moving machines, air-conditioners)
Can also be used as a:
NLULYHSZ^P[JO
LTLYNLUJ`Z[VW

Pack

Cat. No.

Cat. No.

290

190

263

95

102

226 25/27/33/34 100/125 A

332

262

316

132

132

226 35/37

382

292

346

132

132

226 15/17

63 A

160 A

Full load switch units 63 to 160 A


Comprising:
- IP 65 plastic box with transparent hinged cover equipped with a Vistop
with side red handle, yellow front plate with N/C + N/O auxiliary contact
- earth terminal (Viking 3)
63 A - IK 07
Supplied with 2 cable glands 29P - ISO 32

226 15

226 17

3P

cage terminals

50 mm2

4P

50 mm flexible
70 mm2 rigid

50 mm2

100 A - IK 07
Supplied with 2 cable glands 36P - ISO 50
1

226 25

3P

cage terminals

50 mm2

226 27

4P

50 mm2 flexible
70 mm2 rigid

50 mm2

125 A - IK 07
Supplied with 2 cable glands 36P - ISO 50
1

226 33

226 34

3P

cage terminals

50 mm2

4P

50 mm flexible
70 mm2 rigid

50 mm2

160 A - IK 07
Supplied with 2 cable glands 36P - ISO 50
1

226 35

3P

cage terminals

50 mm2

226 37

4P

50 mm2 flexible
70 mm2 rigid

50 mm2

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

39

isolating fuse carriers

SP fuse carriers
with protected terminals

058 06

058 28

215 04

216 01

Dimensions (p. 41)


Conform to IEC 60269-2
Veritas approved
Height under front plate : 44 mm
3 rail mounting or panel mounting
IP2X - IP2XC under front plate

Conform to standard IEC 60269-2/2.1 and to


NF C 63-210. Isolators conform to IEC 60947-3.
Icc: - 20 kA with 8.5 x 31.5 cartridge fuse
- 100 kA with 10 x 38 cartridge fuse
Fuse not supplied
Pack

Cat. No.

Modular fuse carriers


Cartridge dimensions
(mm)

Single pole
10
10

058 06 (1)
058 08

8.5 x 32
10 x 38

058 18

10 x 38
Double pole

058 28

058 38

058 48

1
1

500 V

500 V

10 x 38

500 V

3-pole
10 x 38
3-pole + neutral

10 x 38

500 V

Cat. No.

SP 51 for HRC fuses 14 x 51

Number
of 17.5 mm
modules

400 V
500 V

Single pole + neutral


10

Pack
Voltage

215 01

Single pole

215 04

Triple pole

216 01

Single pole 1 x 50 mm2

216 04

Triple pole

1 x 35 mm2
or
2 x 16 mm2

1.5

2
or
2 x 25 mm2

changeover micro-switch

Blow-out indicator 250 V

057 96

057 99

Early break N/O + N/C contact


auxiliary 5 A - 250 V (0.5 mod.)
Padlock support suitable for 4mm padlocks

Signalling and cut-out functions


Supplied with 3 x 2.8 mm clips

216 36

Triple pole

1 x 50 mm2
or
2 x 25 mm2

Accessory

057 90

4.5

With 5 A - 250 V
3

Accessories
10

Link handle for association


of single pole units
5

216 96

SP 51 or SP 58
Length 300 mm
Can be cut to
required length

40

No of
17.5 mm
modules

SP 58 for HRC fuses 22 x 58

Blow-out indicator

(1) Previously 8.5 x 31.5

Connection

HRC cartridge fuses (p. 43)

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

domestic fuse carriers


for domestic cartridge fuses

SP 51 and SP 58
J
H

4.4

058 21

058 24

With label-holders
With insulated carrier class II O, padlockable
Coupling via supply busbars
Shielded terminals capacity 2 x 10 mm
Indicator to signal blown fuse with Cat. No. 057 90
Pack

Cat. No.

For domestic cylindrical cartridge fuses

B2
B1
U
V

In mm

B1

B2

SP 51
SP 58

106
140

54.5
74

45
65

35
45

51.5
66

55
59

53
53

In mm
SP 51
SP 58

Conform to NF C 61-203 and


IEC 60269-3/3.1
Fuse not supplied

058 14

44

058 11

B1

B2

4.4

J
L
multi.
99
20.7
114 27

U
U
2P 3P
26.5 53
36
72

9
9

U
V
V
4P 1P 2P
79.5 26.5 53
108 36
72

H
1P
81
87

H
multi.
84
90

V
V
3P 4P
79.5 106
108 144

J
1P
96 --111

W
W
1 P multi.
87 90
101 109

Single pole
For
domestic
cartridges

10
10
10
10
10

058 10
058 11
058 12
058 13
058 14

10 A - 230 V
16 A
20 A - 400 V
25 A
32 A

Cartridge
dimensions
(mm)

of 17.5 mm
modules

Number

8.5 x 23
10.3 x 25.8
8.5 x 31.5
10.3 x 31.5
10.3 x 38

1
1
1
1
1

Single pole + neutral


10
10
10
10

058
058
058
058

21
24
20
22

16 A - 230 V
32 A- 400 V
10A - 230 V
20A - 400 V

10.3 x 25.8
10.3 x 38
8.5 x 23
8.5 x 31.5

1
1
1
1

For miniature cylindrical cartridge fuses


To protect sensitive equipment:
transformers, electronic equipment, etc.
Conform to standard IEC 60127-6
Fuse not supplied (see opposite)
Single pole
Cartridge
dimensions
(mm)

058 00

5 x 20

Voltage

250 V

Domestic cartridge fuses (p. 42)

Number
of 17.5 mm
modules

Choice of equipment
Type

Rated current

SP 51

50 A

SP 58

100 A
(125 A in 400 V)

Maximum cartridge
rating
400 V
500 V
690 V
gG aM gG aM gG aM
40

25 25

125 125 100 100

50

50

50

50 50

These values are standardised according to IEC 60269-2/2-1


They can be reduced under certain specific applications

Index of protection: IP 2X - IP 2XC - under casing


Equipment derating
Recommended for equipment exposed to high temperatures:
(TIPLU[[LTWLYH[\YLV]LY*!KLYH[LM\ZLI`VULYH[PUNWLY*
(UTE C 20-051 IEC 60943)
:PKLI`ZPKLLX\PWTLU[PUZPT\S[HULV\ZM\UJ[PVU
2 - 3 devices
4 - 5 devices
6 - 7 - 8 - 9 devices
* 10 devices

0.9
0.8
0.7
0.6

x
x
x
x

ln
ln
ln
ln

This coefficient is to be applied on the nominal rating of the base


(IEC 60439-1)
<UPU[LYY\W[LK\ZHNL!P[TH`ILULJLZZHY`[V\WNYHKL[OLIHZLZ
by one size

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

41

FUSE CARRIERS

>>>

domestic cartridge fuses

Practical and
completely safe
102 63

Pack

Cat. No.

103 06

Miniature type 5 x 20
Instant reaction fuse - Ceramic body
Conform to IEC 60127 - NF EN 60127 VDE 0820-1
High rupture capacity (A)
For use with dimmers, Viking terminals and
emergency lighting units

10
10
10
10
10
10
10
10
10
10
10
10

102 02
102 05
102 06
102 10
102 12
102 16
102 20
102 25
102 30
102 50
102 63
102 96 (1)

Rating

Voltage

(Amps)

(Volts)

0.2
0.5
0.63
1.0
1.25
1.6
2.0
2.5
3.15
5.0
6.3
10.0

Rupture
capacity (Amps)

250

1500

250

500

Cylindrical - without indicator

Rating

Voltage

Rupture

Protected

(Amps)

(Volts)

capacity

section

(Amps)

(mm2)
Copper

103 06 (1)

6.3 x 23
6

10
10
10
10

113 02
113 04
113 06
113 10

8.5 x 23
2
4
6
10

10
10
10

116 06 (2)
116 10 (2)
116 16 (2)

10
10
10
10
10
10
10
10
10

123 01
123 02
123 04
123 06
123 08
123 10
123 12
123 16
123 20

10
10
10

126 16
126 20
126 25

10

133 32

10

10.3 x 25.8
6
10
16

230

6 000

1.5

230

6 000

1.5

230

6 000

2.5

400

20 000

2.5

400

20 000

400

20 000

8.5 x 31.5

Each fuse carrier is designed to take:


- a blow-out indicator
- a padlock
Cartridge totally visible
Class II insulation along the entire length
of the carrier

1
2
4
6
8
10
12
16
20
10.3 x 31.5
16
20
25
10.3 x 38
32
Neutral links

10
10

123 00
133 00

8.5 x 31.5
10 x 38
(1) Overrating not described by standards
(2) Conform to BS 1361 (1971)

42

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

HRC cartridge fuses

120 04

133 08

143 10

140 12

153 96

150 50

Technical data and dimensions (p. 46)


Pack

Cat. No.

Cylindrical type gG

Pack

Cat. No.

Conform to NF C 63-210/211 - EN 60269-1, 2 and IEC 60269-1,


2 & 2-1 Veritas approved without indicator

Conform to NF C 60-200 - EN 60269-1


IEC 60269-1 Veritas approved without indicator (130 XX)

10 X 38 mm 500 V, 100 KA HRC

Without striker (140 XX 150 XX)

Rating (amp)
10

133 94

0.5

10

133 01

10

133 02

10

133 04

10

133 06

10

133 08

10

133 10

10

10

133 12

12

10

133 16

16

10

133 20

20

10

133 25

25

10

133 32

10 X 38mm 500 V, 100 KA HRC


Rating (amp)

32
14 X 51mm 500 V, 100 KA HRC

10

143 02

10

143 04

10

143 06

10

143 10

10

10

143 16

16

10

143 20

20

10

143 25

25

10

143 32

32

10

143 40

10
10
10
10
10
10
10
10
10
10

130
130
130
130
130
130
130
130
130
130

92
95
01
02
04
06
08
10
12
16

10
10

130 20 (2)
130 25 (2)

20
25

10
10
10
10
10
10
10
10
10
10
10

140
140
140
140
140
140
140
140
140
140
140

2
4
6
8
10
12
16
20
25
32
40

40

10
10

140 45 (1)
140 50 (1)

45
50

10
10
10
10
10
10
10
10
10

150
150
150
150
150
150
150
150
150

16
20
25
32
40
50
63
80
96

16
20
25
32
40
50
63
80
100

10

150 97

125

10
10
10
10

123
133
143
153

8.5 X 31.5
10.3 X 38
14 X 51
22 X 58

14 X 51mm 500 V, 100 KA HRC


02
04
06
08
10
12
16
20
25
32
40

14 X 51mm 400 V, 100 KA HRC

14 X 51mm 400 V, 100 KA HRC


143 50 (1)

50
22 X 58mm 500 V, 100 KA HRC

10

153 16

16

10

153 20

20

10

153 25

25

10

153 32

32

10

153 40

40

10

153 50

50

10

153 63

63

10

153 80

80

10

153 96

100

10

153 97

22 X 58mm 500 V, 100 KA HRC

22 X 58mm 400 V, 100 KA HRC


(1)

125

0.25
0.5
1
2
4
6
8
10
12
16
10 X 38mm 400 V, 100 KA HRC

10.3 X 38 mm 500 V, 20 KA HRC

10

Cylindrical type aM (motor rated)

22 X 58mm 400 V, 100 KA HRC

Neutral links
00
00
00
00

(1) Overrating described by standards


(2) Overrating not described by standards

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

43

HRC blade type cartridge fuses


NH type

168 35

178 65

171 60 (with striker)

Technical data and dimensions (p. 46)


Pack

Cat. No.

Pack

Type gG (IEC) / gL (VDE)


Conform to EN 60269-1
IEC 60269-1, 2 and VDE 0636-1
Veritas approved
Fully insulated end plate and handle lugs
Rating
Voltage
Rupture capacity
(Amps)
(Volts)
(Amps)

Cat. No.

10
10
10
10
10
10
10
10
10
10

163 18
163 20
163 22
163 25
163 30
163 35
163 40
163 45
163 50
163 55

With
striker

Size 00
25
32
35
40
50
63
80
100
125
160

500

120000

168 35
168 40
168 45
168 50
168 55
168 60 (1)

63
80
100
125
160
200

With
indicator
3
3
3
3
3
3

With
striker

160 25
160 30
160 35
160 40
160 45
160 50

Size 00
40
50
63
80
100
125

500

120000

400

Size 0

Size 0
3
3
3
3
3
3

Conform to EN 60269-1
IEC 60269-1, 2 and VDE 0636-1
Veritas approved
Fully insulated end plate and handle lugs
Rating
Voltage
Rupture capacity
(Amps)
(Volts)
(Amps)

With
indicator

Type aM (motor rated)

3
3
3
3
3

166 35
166 40
166 45
166 50
166 55

3
3
3
3

170 50
170 55
170 60
170 65

3
3
3
3

175 60
175 65
175 70
175 75

3
3

180 25
180 30

63
80
100
125
160

500

120000

500

120000

500

120000

500

120000

Size 1
500

120000

171 60

125
160
200
250

Size 2
Size 1
3
3
3
3

173 50
173 55
173 60
173 65

125
160
200
250

500

120000

Size 3

Size 2
3
3
3
3

178 60
178 65
178 70
178 75

3
3

181 25
181 30

200
250
315
400

500

500

120000

500
630

Neutral blades

120000

Size 3
500
630

176 70

200
250
315
400

10
1
1
1
1

163 04
168 04
173 04
178 04
181 04

Size 00
Size 0
Size 1
Size 2
Size 3

(1) Overrating not described by standards

44

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

blade type cartridge fuses


accessories

160 00

175 02 base + cartridge size


2 Cat. No. 178 70 + handle 199 02

160 05

Terminal shield 199 22

199 16

Technical data and dimensions (p. 46)


Pack

Cat. No.

Bases for blade type DIN fuses


Screw mounting
Size

Number of
pole

Pack

Cat No.

Accessories for blade DIN fuses

199 02

Handle for all sizes

10

199 09

Size 00 (for cat. No 160 01 and cat. No 162 00)

Separation dividers
Amps

160 00

00

1P

100 A

10

199 15

Size 0

160 04

00

3P

100 A

10

199 16

Size 1

162 00

00

1P

125/160 A

10

199 17

Size 2

162 04

00

3P

125/160 A

199 18

Size 3

160 01

00

1P

100 A

160 05

00

3P

100 A

165 00

1P

160 A

165 02

1P

160 A

165 03

3P

160 A

170 00

1P

250 A

170 02

1P

250 A

170 03

3P

250 A

175 00

1P

400 A

175 02

1P

400 A

175 03

3P

400 A

Terminal shields

DIN rail mounting

DIN rail or screw mounting

For fuse bases


10

199 20

Size 00

10

199 21

Size 0

10

199 22

Size 1

10

199 23

Size 2

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

45

cartridge fuses

HRC cylindrical

Bases for blade type

Size 0 to 3 (continued)
Single pole with micro-switch

57.5

36

M8

Size 0 to 3
Single pole Cat. No. 160 01 - 162 00
10

D
C
7.5

D
7.5
7.5

57

15.5
84
20

39

Blade type
C
B

D2

Triple pole Cat. No. 160 05 - 162 04

D1
M

102

37.5
51.5

20
10
6

M8

37.5

57

84

25

100

L
E

15.5

120

7.5

J
68

Sizes 0 to 3
Single pole without micro-switch
J

1
200
175
72
25
30
25
150
80
28
68
35
46
38
13.5
20
10.5
10
85
215

2
225
200
78
30
30
25
170
80
32
83
35
58
39
13.5
20
10.5
10
90
229

3
250
210
91
41
30
25
158
83
35
92
35
68
40
14
20
10.5
12
94
242

Size 0 - 1 - 2
Triple pole
F

0
171
150
63
20
25
125
75
23
68
24
43
28
11.5
14
7.5
8
75
198

E
M

25

Note: Force of striker at the beginning of


stroke 1.9 kg and 1 kg at the end according
to NF C 63-213

57.5

3
150
61
75
70
64
75
14
2.5
36
6
23
14.5
88
10
18

2
150
64
74
50
50
60
14
3
28
6
19
14.5
72
10
14.5

1
135
64
74
47
47
52
14
3
21
6
16
14.5
64
10
14.5

0
125
62
67
36
39
46
14
2.5
15
6
14.5
14.5
59
10
14.5

Size (mm) 00
A
78
B
44
C
52
D1
30
D2
E
46
F
G
2.5
H
15
I
6
J
K
L
59
M
10
N
14.5

B
A

Size (mm)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S

C
6.3
10
13
16

120

B
31.5
38
51
58

25

A
8.5
10.3
14.3
22.2

100

Size (mm)
8 x 32
10 x 38
14 x 51
22 x 58

Removable handle
23

124

83

46

Size (mm)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S

171
150
47
20
25
125
75
23
68
24
43
28
11.5
14
7.5
8
96
180

200
175
59
25
30
25
150
80
28
68
35
46
38
13.5
20
10.5
10
107
224

225
200
67
30
30
25
170
80
32
83
35
58
39
13.5
20
10.5
10
121
240

250
210
82
41
30
25
158
83
35
92
35
68
40
14
20
10.5
12
110
266

Size (mm)
A
B
C
D

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

0
171
48
144
67

1
200
62.5
180
81

2
225
68
204
93

selection charts

Example of good selection

How to select a protection system ?


Depending on the type of failure, overload or short-circuit, use 2 series
of data
1. Overloads: use the operating zone curves of the different protection
devices. On the same row, the operating zones should not overlap
2. Short-circuits:\ZL[OLP2[[HISLZ;OL[V[HSP2t of the protection
system the furthest downstream must be less than the upstream
WYV[LJ[PVUWYLHYJP2t

Selection between cartridge fuses (according to IEC 60269-2-1)


Upstream
rating
gG cartridge fuse
(A)

Downstream
maximum rating determined according to class
and voltage to obtain selection
aM

2
4
6
8
10
12
16
20
25
32
35
40
50
63
80
100
125
160
200
250
315
400
500
630

gG

1
2
2
2
2
4
6
8
10
12
12
16
20
25
36
40
63
80
125
125
160
200
250

Upstream
rating
aM cartridge fuse
(A)

Downstream
maximum rating determined according to class
and voltage to obtain selection
aM
1
2
2
4
6
6
10
12
12
20
20
25
25
40
50
63
80
100
125
160
200
250
315
400

2
4
6
8
10
12
16
20
25
32
36
40
50
63
80
100
125
160
200
250
315
400
500
630

1
2
2
4
4
6
10
16
20
20
25
32
40
50
63
80
100
125
160
200
250
315
400

gG
1
4
6
8
10
12
16
20
25
32
32
32
40
50
63
80
100
125
160
160
200
250
315
400

Motor protection
Motor three-phase
400 V

230 V
kW
0.37
0.75
1.1
1.8
2.2
3
4
5.5
7.5
10
11
15
18.5
22
25
30
45
55
75
80
90
110
132
160

Hp

In A

kW
0.37
0.5 1.8 0.75
1
3.5 1.5
1.5 4.4 2.2
2.5
7
3
3
8.7
4
4
11.5 5.5
5.5 14.3 7.5
7.5
20
11
10
27
15
13.5 35 18.5
15
39
22
20
52
25
25
64
30
30
75
37
35
85
45
40 103 55
60 147 75
75 182 90
100 239 110
160 260 132
125 295 160
150 356 200
180 425 250
218 520 315

Hp
0.5
1
2
3
4
5.5
7.5
10
15
20
25
30
34
40
50
60
75
100
125
150
180
218
270
340
430

500 V

In A kW
1.03 0.75
2
1.5
3.5 2.2
5
3.7
6.6
4
8.5 5.5
11.5 7.5
15.5 11
22
15
30 18.5
37
25
44
30
51
40
60
45
72
51
85
63
105 80
138 110
170 132
205 160
245 220
300
370 250
475 335
584 450

Hp
1
2
3
5
5.5
7.5
10
15
20
25
34
40
54
60
70
109
110
150
180
220
300

In A
1.5
2.6
3.8
5.9
6.5
9
12
18.4
23
28.5
39.4
45
60
65
75
89
112
156
187
220
310

340
450
610

360
472
608

10 x 38
ratings
gG
aM
4
2
6
4
8
4
12
6
16
8
20
10
25
12
20 (1)
20 (1)

14 x 51
22 x 58
ratings
ratings
gG
aM gG
aM
4
2
6
4
8
4
12
6
16
8
16
20
10
20
25
12
25
32
20
32
20
50
25
50
25
32
50
32
40
63
40
50
50 (1) 80
100
63
80
80
100
125 (1)

S. 00
ratings
gG
aM

25
32
50
50
63
80
100
125
125
160

20
25
32
40
50
63
80
80
100
125

Cartridges
S. 0
ratings
gG
aM

63
80
100
125
125
160
200

63
80
80
100
125
160

S. 1
ratings
gG
aM

125
125
160
200
250

125
160
200
250

S. 2
ratings
gG
aM

200
250
315
400

S. 3
ratings
gG
aM

200
250
315
315
400
500
630

(1) 400 V max.

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

47

blade cartridge fuses gG and aM types

The gG or aM types protect the conductors of electrical circuits in the event of overbad or short-circuit
gG cartridge fuses:
The selectivity ratio is 1.6 instead of 2
The breaking capacity of 120000 A provides full protection in the most critical situations
aM cartridge fuses:
These cartridge fuses must be combined with a low-overload thermal protection device
The breaking capacity of 100000 A from size 10 x 38 upwards provides full protection in the most critical situations
Cylindrical industrial cartridge fuses can be used to protect DC circuits supplied at up to 48 V max.

Rupture capacity curves


aM type
25
32
35
40
50
63
80

Times in seconds
10 000

100
125
160
200
250
315
400
500
630

gG type
10 000

1 000

1 000

Time in seconds
10 000

10 000

1 000

1 000

100

100

100

10

10

10

10

0.01
1

10

100
1 000
Current in Amps

0.01
100 000

10 000

0.1

0.1

0.1

0.1

25
32
40
50
63
80
100
125
160
200
250
315
400
500
630

100

0.01
1

10

100
1 000
Current in Amps

Thermal stresses ( I2dt)


gG type (for 500 V

aM type for 500 V

10 000 000

10 000

- except 1250 A for 400 V

10 000 000

Thermal stress in A s

1 000 000

1 000 000

Thermal stress in A s

100 000

10 000

1 000
100
25

50

35
40

32

80
63

315
500
125
200
400
630
100
160
250
Rating in Amps

100 000

10 000

1 000

Total maximum thermal stress for critical current


Pre-arc thermal stress for critical current

100

25

40
32

63
50

80

gG (1) type limitation curve

Consumption in watts when hot, at rated current

100
630
500
400
315
250
200
160
125
100
80
63
50
40
32
25

Limited currents at peak kA

30

10

2.5

Ief

0.3
0.1
0.1

0.2

0.5

1
2
5
10
Prospective short-circuit at kA rms

20

50

100

(1) For aM cartridge fuses, see technical data sheets in the Legrand e-catalogue

48

100 160 250 400 630


125 200 315 500
Rating in Amps

Fuse
ratings (A)
25
32
35
40
50
63
80
100
125
160
200
250
315
400
500
630

Cartridge fuses
gG
Size 00
2.1
3
3
3.3
4.5
6
7
7.5
13
15

aM
Size 0 to 4

4.2
5.5
6.5
8.5
9.5
12
15
19
23
24
33
36
45

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

Size 00
1.3
1.8
2.5
3
3.6
5.2
6
7

Size 0 to 4

3.9
5.5
6.5
8.5
11.5
13.5
17
24
28
34
41

0.01
100 000

49

NEW

P. 56
DX-E; DX 6000
MCBs from
1 to 63A

Protection:
- DX
- DX-E
- DX-H
- DX-D
- RCD
- RCBO

P. 58
DX-D MCBs
up to 63A
D curve

P.64
Surge protection

Voltage surge
protectors, fuse
carriers and fuses

A1
1

Contactors and
time switches
2

P. 68
Modular
contactors

4
A2

P. 75
AlphaRex Astro
digital

Lexic
Din-rail
equipment
NEW
25 A
Power contactors
(P.68)

50

P. 57
DX-H 10000
MCBs from 1 to 63A

P. 58
DX-D
MCBs from 6 to 63A

P. 59
DX RCBO
RCD

P. 60
Auxiliaries

P. 61
Technical
characteristics

P. 66
Technical
characteristics

18
4

12
10

P. 73
AlphaRex
4 channel
digital

14

18

16

12

P. 79
Hour counter

16

10

P. 77
Electro-mechanical
surface mounting

14

P. 76
Electro-mechanical
Din

24

24

P. 72
EcoRex
digital

22

22

P. 71
MicroRex
digital

20

20

P. 70
AlphaRex
digital

51

Lexic DIN-Rail equipment:


the distribution board
the way you want it
Complete and innovative functions for commercial buildings
with the freedom to organise the distribution board as you please.

THEY HAVE SPECIFIED AND


INSTALLED LEGRAND PRODUCTS:
UNSW Living Apartment Village: Kensington Sydney | NSW
Koniambo Mines: New Caledonia
STAHL Building DOF: Bandiana, Wodonga | NSW
Main Roads Dept (Traffic Signal): SE | QLD
Hogs Breath: Coolongatta | QLD
KFC Building: North Albury | VIC
Goodman Fielder Bakery: Wacol | QLD

52

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DISTRIBUTION BOARDS

PROTECTION

MCBs AND RESIDUAL current


PROTECTION DEVICES
(See p. 56)
DX-E, DX, DX-H, DX-D,
different breaking capacities
for maximum protection

(See p. 85)

ISOLATION
SWITCHES
VistopTM 63
to 160 A
(See p. 31)

VOLTAGE SURGE
PROTECTORS
(See p. 64-65))
Efficient protection
against lightning effects

SWITCHES AND REMOTE CONTROL


NEW

NEW

This symbol indicates


energy saving product

POWER CONTACTORS
(See p. 68)
Can control loads
up to 63 A

PROGRAMMABLE
TIME SWITCHES
(See p. 70)
For switching ON
and OFF an electric circuit
for pre-programmed periods

LIGHT SENSITIVE
SWITCHES
(See p. 75)
Automatic control of
different loads, based
on lighting conditions
(nightfall/daybreak)

53

DX-series Miniature Circuit Breakers

Designation

DX-E 6000 /6kA

DX 6000 /6kA

1P

2P

3P

4P

1P

2P

1/2/3/6/10/13/
16/20/25/32
40/50/63

1/2/3/6/10/13/
16/20/25/32
40/50/63

1/2/3/6/10/13/
16/20/25/32
40/50/63

1/2/3/6/10/13/
16/20/25/32
40/50/63

1/2/3/6/10
16/20/25/32
40/50/63

1/2/3/6/10
16/20/25/32
40/50/63

B and C

B and C

B and C

B and C

B and C

B and C

Nominal voltage (with standard tolerance)

230/400 V

400 V

400 V

400 V

230/400 V

400 V

Nominal frequency

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

Operating voltage (50/60 Hz) +/- 10%

240/415 V

415 V

415 V

415 V

240/415 V

415 V

6000 A

6000 A

6000 A

6000 A

6 000 A

6 000 A

6000 A

6000 A

6000 A

6000 A

6 000 A

6 000 A

6 kA

6 kA

6 kA

6 kA

10 kA

Curve B: 25 kA
Curve C:
0U(!R(
In > 32 A: 20 kA

6 kA

6 kA

6 kA

6 kA

10 kA

10 kA

Standard breaking capacity Ics acc. to


AS 60947-2

100%

100%

100%

100%

100%

100%

Rated insulation voltage Ui


(degree of pollution 2)

500 V

500 V

500 V

500 V

500 V

500 V

6 kV

6 kV

6 kV

6 kV

6 kV

6 kV

20 000

20 000

20 000

20 000

20 000

20 000

10 000

10 000

10 000

10 000

10 000

10 000

2 500 V

2 500 V

2 500 V

2 500 V

2 500 V

2 500 V

Remote control

yes

yes

Add-on module

yes

-25 C to + 70 C

-25 C to + 70 C

-25 C to + 70 C

-25 C to + 70 C

-25 C to + 70 C

-25 C to + 70 C

Number of poles

Rated current in at 30 C (A)


Ratings

Type of curve

Breaking capacity with 127/230 V supply


Icn 50/60 Hz
acc. to AS/NZ560898.1 with 240/415 V
supply

Breaking capacity
Icu 50/60 Hz with 127/230 V supply
acc. to AS 60947-2 with 240/415 V supply

Rated impulse withstand current Uimp


(kV)

Endurance
(operating cycles)

mechanical
electrical

Dieletric strength between 0 and 2000 m

Operating temperature

54

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DX 6000 /6kA

DX-H 10000 /10kA

DX-D 6000 - I0KA

3P and 4P

1P

2P

3P, 4P

1P

2P

3P and 4P

1/2/3/6/10
16/20/25/32
40/50/63

1/2/3/6/10
13/16/20/25
32/40/50/63
80/100/125

1/2/3/6/10
13/16/20/25
32/40/50/63
80/100/125

1/2/3/6/10
13/16/20/25
32/40/50/63
80/100/125

1/2/3/6/10/
13/16/20/25
32/40/50/63

1/2/3/6/10
16/20/25/32
40/50/63
80/100/125

1/2/3/6/10
16/20/25
32/40/50/63
80/100/125

B and C

B and C

B and C

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

415 V

240/415 V

415 V

415 V

240/415 V

415 V

415 V

6 000 A

10 000 A

10 000 A

10 000 A

6 000 A

6 000 A

6 000 A

6 000 A

10 000 A

10 000 A

10 000 A

6 000 A

6 000 A

6 000 A

Curve B: 25 kA
Curve C:
0U(!R(
In > 32 A: 20 kA

25 kA

0U(!R(
In > 40 A: 25 kA

0U(!R(
In 50/63 A: 25 kA
In > 63 A: 16 kA

0U(!R(
0U(!R(
In > 63 A: 16 kA

0U(!R(
0U(!R(
In > 63 A: 16 kA

0U(!R(
0U(!R(
In > 63 A: 16 kA

10 kA

0U(!R(
In 25 A: 20 kA
In 32 A: 15 kA
In > 32 A: 12,5 kA

0U(!R(
In 25 A: 25 kA
In 32/40 A: 20 kA
In > 40 A: 15 kA

0U(!R(
In 25 A: 20 kA
In 32/40 A: 15 kA
In > 40 A: 12,5 kA

0U(!R(
In > 32 A: 10 kA

0U(!R(
In > 32 A: 10 kA

0U(!R(
In > 32 A: 10 kA

100%

75%

75%

75%

75%

80%

75%

500 V

500 V

500 V

500 V

500 V

500 V

500 V

6 kV

6 kV

6 kV

6 kV

6 kV

6 kV

6 kV

20 000

20 000

20 000

20 000

20 000

20 000

20 000

10 000

10 000

10 000

10 000

10 000

10 000

10 000

2 500 V

2 500 V

2 500 V

2 500 V

2 500 V

2 500 V

2 500 V

yes

yes

yes

yes

yes

(!yes

(!yes

yes

yes

yes

yes

yes

-25 C to + 70 C

-25 C to + 70 C

-25 C to + 70 C

-25 C to + 70 C

-25 C to + 70 C

-25 C to + 70 C

-25 C to + 70 C

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

55

DX-ETM 6 000 - 6kA

DXTM 6 000

thermal magnetic MCBs from 6 to 63A


C curve

thermal magnetic MCBs from 1 to 63A


C curve
Approval No: N19929

Approval No: N19929

Breaking capacity according


to AS/NZS 60898-1
Icn (o-co cycle): 6000A

Breaking capacity according


to AS/NZS 60898-1
Icn (o-co cycle): 6000A

Do not accept add-on


modules.
Technical characteristics (p. 61)
033 86

034 33

034 53

Technical characteristics (p. 61)


Pack

10
10
10
10
10
10
10
10
10

Cat. No.

064 68
Pack

Single pole - 230/400 V

C
curve

Nominal
rating
(A)

033 82
033 84
033 86
033 87
033 88
033 89
033 90
033 91
033 92

6
10
16
20
25
32
40
50
63

Number
of 17.5 mm
modules

1
1
1
1
1
1
1
1
1

1
1
1
1
10
10
1
1
1
1
1
1

Cat. No.

C
curve

Nominal
rating
(A)

063 68
063 69
063 70
063 72
063 74
063 76
063 77
063 78
063 79
063 80
063 81
063 82

1
2
3
6
10
16
20
25
32
40
50
63

034
034
034
034
034
034
034
034

29
31
33
34
35
36
37
38

6
10
16
20
25
32
40
50

2
2
2
2
2
2
2
2

034 39

63

3 pole - 400 V
C
curve

Nominal
rating
(A)

1
1
1
1
1
1
1
1

034 47
034 49
034 51
034 52
034 53
034 54
034 55
034 56

6
10
16
20
25
32
40
50

3
3
3
3
3
3
3
3

034 57

63

1
1
1
1
1
1
1
1
1

56

C
curve

Nominal
rating
(A)

034 89
034 91
034 93
034 94
034 95
034 96
034 97
034 98
034 99

6
10
16
20
25
32
40
50
63

1
1
1
1
5
5
1
1
1
1
1
1

C
curve

Nominal
rating
(A)

064 60
064 61
064 62
064 64
064 66
064 68
064 69
064 70
064 71
064 72
064 73
064 74

1
2
3
6
10
16
20
25
32
40
50
63

Number
of 17.5 mm
modules

4 pole - 400 V
Number
of 17.5 mm
modules

4
4
4
4
4
4
4
4
4

Number
of 17.5 mm
modules

1
1
1
1
1
1
1
1
1
1
1
1

Double pole - 230/400 V

Number
of 17.5 mm
modules

5
5
5
5
5
5
5
5

Single pole - 230/400 V

C
curve

Double pole - 230/400 V


Nominal
rating
(A)

063 76

Number
of 17.5 mm
modules

2
2
2
2
2
2
2
2
2
2
2
2

3-pole - 400 V

1
1
1
1
1
1
1
1
1
1
1
1

C
curve

Nominal
rating
(A)

064 80
064 81
064 82
064 84
064 86
064 88
064 89
064 90
064 91
064 92
064 93
064 94

1
2
3
6
10
16
20
25
32
40
50
63

Number
of 17.5 mm
modules

3
3
3
3
3
3
3
3
3
3
3
3

4-pole - 400 V

1
1
1
1
1
1
1
1
1
1
1
1

C
curve

Nominal
rating
(A)

065 55
065 56
065 57
065 59
065 61
065 63
065 64
065 65
065 66
065 67
065 68
065 69

1
2
3
6
10
16
20
25
32
40
50
63

Number
of 17.5 mm
modules

4
4
4
4
4
4
4
4
4
4
4
4

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

DX-H 10 000
thermal magnetic MCBs
high breaking capacity from 1 to 63A
C curve

Approval No: N19929

069 20

068 60

070 00

069 46

Technical characteristics (p. 61)


Breaking capacity according
to AS/NZS 60898-1
Icn (o-co cycle): 10KA

Pack

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Cat. No.

Single pole - 230/400 V

C
curve

Nominal
rating
(A)

Number
of 17.5 mm
modules

068 52
068 53
068 54
068 56
068 58
068 60
068 61
068 62
068 63
068 64
068 65
068 66
063 83
063 84
063 85

1
2
3
6
10
16
20
25
32
40
50
63
80
100
125

1
1
1
1
1
1
1
1
1
1
1
1
1,5
1,5
1,5

Pack

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Cat. No.

C
curve

Nominal
rating
(A)

Number
of 17.5 mm
modules

069 32
069 33
069 34
069 36
069 38
069 40
069 41
069 42
069 43
069 44
069 45
069 46
064 95
064 96
064 97

1
2
3
6
10
16
20
25
32
40
50
63
80
100
125

3
3
3
3
3
3
3
3
3
3
3
3
4,5
4,5
4,5

Double pole - 230/400 V

1
1
1
1
1
1
1
1
1
1
1
1

C
curve

Nominal
rating
(A)

Number
of 17.5 mm
modules

069 12
069 13
069 14
069 16
069 18
069 20
069 21
069 22
069 23
069 24
069 25
069 26

1
2
3
6
10
16
20
25
32
40
50
63

2
2
2
2
2
2
2
2
2
2
2
2

3-pole - 400 V

4-pole - 400 V

1
1
1
1
1
1
1
1
1
1
1
1

C
curve

Nominal
rating
(A)

Number
of 17.5 mm
modules

069 92
069 93
069 94
069 96
069 98
070 00
070 01
070 02
070 03
070 04
070 05
070 06

1
2
3
6
10
16
20
25
32
40
50
63

4
4
4
4
4
4
4
4
4
4
4
4

Auxiliaries/accessories (p. 60)

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

57

DX-D 6 000

DXTM

thermal magnetic MCBs up to 63 A


D curve

RCD add-on modules for DX, DX-H


and DX-D 6 kA
Approval No: N19929

066 36

Approval No: 19930

066 71

Breaking capacity according


to AS/NZS 60898-1
Icn (o-co cycle): 10KA
Technical characteristics (p. 61)

Pack

1
1
1
1
1
1
1
1
1

Cat. No.

Single pole - 230/400 V

D
curve

Nominal
rating
(A)

Number
17.5 mm
modules

065 79
065 81
065 83
065 84
065 85
065 86
065 87
065 88
065 89

6
10
16
20
25
32
40
50
63

1
1
1
1
1
1
1
1
1

1
1
1
1
1
1
1
1
1

066
066
066
066
066
066
066
066
066

29
31
33
34
35
36
37
38
39

Conform to AS/NZS 61009-1


RCD add-on module type AC
Mounted on the right-hand side
of the MCBs DX, DX-H and DX-D 6 kA
Pack

Cat. No.

Type AC
Double pole - 230/400 V
Sensitivity

Double pole - 230/400 V


D
curve

074 02

Nominal
rating
(A)

Number
17.5 mm
modules

6
10
16
20
25
32
40
50
63

2
2
2
2
2
2
2
2
2

074 02

Maximum
rating
(A)

Number
of 17.5 mm
modules

63

30mA

Sensitivity

074 29

Maximum
rating
(A)

Number
of 17.5 mm
modules

63

30mA

066
066
066
066
066
066
066
066
066

49
51
53
54
55
56
57
58
59

6
10
16
20
25
32
40
50
63

58

7
T

Number
17.5 mm
modules

3
3
3
3
3
3
3
3
3

Maximum
rating
(A)

D
curve

Nominal
rating
(A)

Number
17.5 mm
modules

066 69
066 71
066 73
066 74
066 75
066 76
066 77
066 78
066 79

6
10
16
20
25
32
40
50
63

4
4
4
4
4
4
4
4
4

Number
of 17.5 mm
modules

074 55

30mA

32

074 56

30mA

63

4-pole - 400 V

1
1
1
1
1
1
1
1
1

4-pole - 400 V
Sensitivity

1
1
1
1
1
1
1
1
1

2 4

Nominal
rating
(A)

3-pole - 400 V

3-pole - 400 V
D
curve

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

2 4

DXTM 6 000

DXTM

RCBO up to 40 A - type AC
residual current devices - type AC

residual current devices


type AC
Approval No: 19931

Approval No: 19931

078 86

090 12

089 28
6064 12

Conform to AS/NZS61008-1
Pack

Cat. No.

Type AC
Single pole + neutral - 230V

Pack

Cat. No.

Neutral on right hand side


Breaking capacity 6000A
AS/NZS61009-1

Sensitivity

1
1
1
1
1
1
1

078 79
078 84
078 86
078 87
078 88
078 89
078 90

10ma
30ma
30ma
30ma
30ma
30ma
30ma

Nominal
rating
(A)

Number
of modules

16
10
16
20
25
32
40

2
2
2
2
2
2
2

Type AC
(1) (2)
Single pole + neutral - 230V
Breaking capacity
10000 A - AS/NZS61009-1

Sensitivity

1
1
1
1
1
1

6064
6064
6064
6064
6064
6064

10
11
12
13
14
15

30ma
30ma
30ma
30ma
30ma
30ma

Nominal
rating
(A)

Number
of modules

10
16
20
25
32
45

1
1
1
1
1
1

1
1
1
1
1
1

089
089
089
089
089
089

09
10
11
16
17
28

Type AC
2 - pole - 230V
Sensitivity

Nominal
rating
(A)

Number
of modules

30ma
30ma
30ma
100ma
300ma
300ma

25
40
63
40
63
40

2
2
2
2
2
2

4 - pole - 400V
Neutral on right-hand side

1
1
1
1
1
1
1
1

089 93
089 94
089 95
089 96
090 00
090 12
090 13
090 14

Sensitivity

Nominal
rating
(A)

Number
of modules

30ma
30ma
30ma
30ma
100ma
300ma
300ma
300ma

25
40
63
80
40
40
63
80

4
4
4
4
4
4
4
4

(1) Single pole with solid unswitched neutral


A type of RCD/RCBO See HPM Catalogue section 1

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

59

auxiliaries for MCBs, RCDs. RCBOs

accessories for MCBs, RCDs. RCBOs

and isolating switches

073 50

Pack

073 54

Cat. No.

073 61

Auxiliaries for MCBs, RCBOs

Pack

Up to 125 A and Residual current devices


Clip on the left-hand side of the MCB
(maximum 3) *

073 50

073 51

1


073 53


073 54

073 61

1
1
1

073 65
073 66
073 68

Auxiliary changeover
switch. 6 A - 250 V
Indicates the position of
the switches
Fault signalling changeover switch.
6 A - 250 V
Indicates tripping of the
MCB at a fault
Auxiliary changeover 6 A - 250 V
Z^P[JO^OPJOJHUILTVKPLK
to a fault signalling switch
Auxiliary changeover 6 A - 250 V
switch + fault signalling
Z^P[JOJHUILTVKPLK
to 2 auxiliary changeover
switches
Command auxiliaries
Shunt trip
Enable the MCB to be
tripped from a remote location
110 to 415 V
110 to 125 V
Minimum voltage trips.
Time delay adjustable
from 0 to 300 ms
24 V
48 V
230 V

044 42

=
=

Support for 4 mm
or 6 mm padlock for DX, DX-H,
MCBs and 2 P RCDs

0.5

Terminal shields
1

044 39

Single pole for DX MCBs from


80 A to 125 A

Accessories
Padlocking

Number
of 17.5 mm
modules

Signalling auxiliaries
1

Cat. No.

073 68

044 47

Insulating shields for DX MCBs


and DX-H

1
1
1

*Auxilliary common to: DX / DX-H / RCDS / RCBOS / DX-IS

60

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

performance of MCBs and auxiliaries

Breaking capacity in the event of a short-circuit to earth


and insulation voltage
DX
Single pole
+ Neutral

DX
B and C curves
D curve < 63 A

DX-H
B and C curves
DX D curve
80 to 125 A

DX-L
C curve

Icn 1

4500 A

6 kA

10 kA

25 kA

Ui

250 V

500 V

500 V

500 V

Technical characteristics of DX auxiliaries


- Max. connection cross-section: 2.5 mm2
- Operating temperature: - 5 to + 50 C
Current shunt releases

nominal voltage (Un)


- 12 to 48 V and
- 110 to 415 V 110 to 125 V
Fitted with automatic breaking
contact

Icn 1: Breaking capacity on 1 pole for multi-pole MCBs in the event of a


short-circuit to earth
Ui: rated insulation voltage

Connection cross-section for screw terminals (in mm2)


Copper cable
rigid

exible

s$8SINGLEPOLE NEUTRAL
with or without add-on modules

16

10

s$8 ADD ONMODULES) 63 A


DX-L add-on modules

32

25

s$8 ( ADD ONMODULES  !


DX-L

70

50

s!UXILIARIES

2.5

2.5

Min. and max. voltage: from 0.7 to 1.1 Un


Tripping time: < to 20 ms
Power consumption: at 1.1 x 48 V = 121 VA
at 1.1 x 415 V = 127 VA
0TWLKHUJL![V=$
[V=$

Consumption

U min.

U max.

12 to 48 V
110 to 415 V

522 mA
69 mA

2610 mA
259 mA

Undervoltage releases
nominal voltage (Un)
24 V
48 V
230 V

=
=

Release curves of MCBs


t (time)

7\SSPU]VS[HNL!<U
Tripping time: from 100 to 400 ms 10% (adjustable)
Power consumption: 24 V= 0.1 VA
48 V= 0.2 VA
230 VA 1 VA

Thermal
(low overvoltage:
slow release)
1h

Z B

Magnetic
(high overvoltage:
fast release)

0.01 s

1
10
20 30 50
100
200
2 3 4 5
1.3
B
C
D
x In (rating)
1.45
Thermal release for an ambient temperature = 30 C

Curves
Z (1)
B
C
D
MA (1)

Magnetic threshold setting


2.4 to 3,6 In
3 to 5 In
5 to 10 In
10 to 14 In (10 to 20 depending on standard)
12 to 14 In

(1) Please consult us

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

61

performance of MCBs and auxiliaries (continued)

Example: circuit earthed via the negative polarity / U = 110 V= / Isc = 10


kA / In = 32 A
Protect the positive polarity using an MCB capable of breaking 10 kA at
110 V (DX-H 2P 32 A with 2 poles on the positive polarity)
For isolation, use a DX-H 3P 32 A with 2 poles on the positive polarity
and one pole on the negative polarity

Protection of DC circuits
3L_PJ+?HUK+?/4*)Z77770U(KLZPNULKMVY\ZLPU
230/400 V supplies, can also be used in DC circuits
In this case, the following deratings and precautions must be taken into
account
1 - Protection against short-circuits
Max. magnetic tripping threshold: multiplied by 1.4
Example: For a C curve MCB for which the AC tripping threshold is
between 5 and 10 In, the DC tripping threshold will be between
7 and 14 In

DX-H LEXIC
Acc. to 

IEC 60947.2 Icu

voltage

single-pole

2P

48 V

10 kA

10 kA

110 V

10 kA

3P

4P

10 kA

230 V

15 kA

2 - Protection against overloads


The time/current thermal tripping curve is the same as for AC
3 - Operating voltage
Max. operating voltage: 80 V per pole (60 V for single-pole + N MCBs)
For voltages higher than this value, several poles must be wired in series
Example: for a 110 V voltage, use
a 2-pole MCB and connect the 2
poles in series
s.ETWORKEARTHEDVIAAMIDDLEPOINT
Place on each polarity the number of poles necessary for max. Isc breaking
at half voltage

4 - Breaking capacity
4000 A for a single pole MCB at max. voltage (80 V= per pole)
At other voltages, the breaking capacities are as follows:
+

DX

voltage

Acc. to 

 48 V

single-pole

2P

6 kA

6 kA

110 V

IEC 60947.2 Icu

6 kA

3P

10 kA
100 %

100 %

voltage
 48 V

Acc. to
IEC 60947.2 Icu

single-pole

2P

10 kA

10 kA
10 kA

3P

110 V
230 V

single-pole

2P

48 V

6 kA

6 kA

110 V

6 kA

3P

4P

6 kA
10 kA

4P

10 kA

230 V
Ics (1)

voltage

230 V

100 %

110 V
48 V

IEC 60947.2 Icu

100 %

230 V
DX-H

DX LEXIC
Acc. to 

100 %

110 V

Ics (1)

Example: circuit earthed via a middle point / U = 230 V= / Isxc = 6 kA /


In = 10 A
Protect each polarity using an MCB capable of breaking 6 kA at half
voltage, i.e. 115 V (DX 4P 10 A with 2 poles on each polarity)

6 kA

230 V
48 V

4P

15 kA
100 %

100 %
100 %

100 %
100 %

5 - Distribution of breaking poles


To choose the MCB and determine the pole distribution necessary
for breaking on each of the polarities, it is necessary to know how the
installation is earthed
sSupply with one polarity earthed:
Place all the poles necessary for breaking on the other polarity If isolation
is required, an additional pole must be added on the earthed polarity

s)SOLATEDEARTHSUPPLY:
Distribute the poles necessary for breaking over the 2 polarities to provide
protection in the event of a double earth fault (particularly if there are a
number of circuits in parallel)

Example: isolated earth circuit / U = 48 V= / Isc = 4,5 kA / In = 40 A


Protect the installation with an MCB capable of breaking 4.5 kA at
48 V and protect each polarity (DX MCB 2P 40 A with one pole on
each polarity)
DX LEXIC
Acc. to

IEC 60947.2 Icu

voltage

single-pole

2P

48 V

6 kA

6 kA

110 V

6 kA

230 V

(1) As a % of Icu

62

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

3P

4P

6 kA
10 kA

performance of MCBs and auxiliaries (continued)

RCD tripping curves

2P and 4P RCDs: withstand to short-circuits

(]LYHNL9*+VWLYH[PUNJ\Y]LZ

Caution: it is advisable to provide overload protection for the RCD

1
t(s)

Downstream
RCD

0.5
10mA

30mA

300mA

1A

2P/
4P

0.1

Upstream cartridge fuse


gG
) 40 A 63 A

80 A 100 A

Upstream MCB
DX (B/C)

DX-H (B/C)
DPX
80 < DX-L 125
125 A

1P+N 2,3,4P ) 63 A

16 A

100 kA 50 kA 15 kA 10 kA

6 kA 10 kA 20 kA (1) 12.5 kA 50 kA 25 kA

25 A

100 kA 50 kA 15 kA 10 kA

6 kA 10 kA 20 kA (1) 12.5 kA 50 kA 25 kA

40 A

100 kA 50 kA 15 kA 10 kA

6 kA 10 kA 15 kA (1) 12.5 kA 50 kA 25 kA

63 A

100 kA 50 kA 15 kA 10 kA

80 A

100 kA 50 kA 15 kA 10 kA

100 A

100 kA 50 kA 15 kA 10 kA

10 kA

12.5 12.5 kA 50 kA 25 kA
kA(1)
12.5 12.5 kA
25 kA
kA (1)
12.5 12.5 kA
25 kA
kA (1)

(1) Same nominal rating for both, MCB and RCD


A, AC or Hpi
type selective (s)

0.05

DX RCBOs residual current breaking capacity


Hpi type
A or AC type
instantaneous

I m according to EN 61009-1
Add-on modules
- DX 6000 , DX-H, D curve

6000 A

RCBOs
-P+N

3000 A

- 2P (4 modules)

6000 A

- 4P 10 to 32 A (4 modules)

4500 A

- 4P 40 to 63 A (7 modules)

6000 A

0.01
10

10

10

10

I (mA) 10

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

63

DISTRIBUTION BOARDS

>>>

voltage surge protectors

Spacious
design
Legrand Distribution Boards are spacious
and expandable for control wiring. They are
designed to suit Commercial and Industrial.

039 21

039 33

039 34

Technical characteristics (p. 64)

Type 2 voltage surge protectors (V.S.P.) for main boards, distribution


boards and consumer units
Conform to standards IEC 61643-1 and EN 61643-11
3 different impulse discharge ratings
For 230/400 VA - 50/60 Hz networks
Pack

Cat. No.

Main board protection


High protection - H - Class I + II Imax = 70 kA
Earthing systems: TT, TN, IT
Consist of a base and a plug-in replacement module provided with a status
indicator
.YLLU!Z\YNLWYV[LJ[VYVWLYH[PVUHS
6YHUNL!TVK\SLULLKZYLWSHJPUN
Can be equipped with auxiliary contacts for remote monitoring purpose
(p. 108)

1
1
1
1

039 20 (1)
039 21 (1)
039 22 (1)
039 23 (1)

Number of
poles

Associated
protection

Number of
modules

1P
2P
3P
4P

40A - C curve
40A - C curve
40A - C curve
40A - C curve

1
2
3
4

Distribution board protection


For electrical equipment located at more than 30 m from the main
distribution board
Consist of a base and a plug-in replacement module provided with a
status indicator
.YLLU! surge protector operational
6YHUNL! module needs replacing
Can be equipped with auxiliary contacts for remote monitoring purpose
(p. 108)
Increased protection - I - Class II - Imax= 40 kA
Earthing systems: TT, TN, IT
1
1
1
1

039 30 (1)
039 31 (1)
039 32 (1)
039 33 (1)

Number of
poles

Associated
protection

1P
2P
3P
4P

20A - C curve
20A - C curve
20A - C curve
20A - C curve

Number
of modules

1
2
3
4

Standard protection - S - Class II - Imax= 15 kA


Earthing systems: TT, TN

Ample space:
- space for additional din rail equipment
- extra space for cabling
- full accessibility from top and bottom
Ready to use:
- equipped with standard 250A main switch
Chassis:
- type tested up to 400A
- complete solutions from 24 poles to 84 poles
Designed and manufactured in Australia

64

1
1
1

039 40
039 41 (1)
039 43 (1)
(1)

Number of
poles

Associated
protection

1P
2P
4P

20A - C curve
20A - C curve
20A - C curve

Number
of modules

Replacement modules for type 2 V.S.P.


5
5
5
5

039 28
039 34
039 44
039 39

For V.S.P. Cat. No. 039 20/21/22/23


For V.S.P. Cat. No. 039 30/31/32/33
For V.S.P. Cat. No. 039 40/41/43
For V.S.P. Cat. No. 039 35/36/38
(old model voltage surge protector)
(1) Associated protection: MCBs DX, DX-H, DX-L or equivalent
ranges according to required breaking capacity

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

1
2
4

voltage surge protectors


for telephone lines and
accessories for low voltage V.S.P.

voltage surge protectors

038 28

038 29

Lightning directly or indirectly generates the following effects:


[OLYTHSISV^V\[ZMPYL
LSLJ[YVK`UHTPJSVVZLUPUNVM[LYTPUHSZ
YPZLPULHY[O]VS[HNLYPZRVMLSLJ[YVJ\[PVU
V]LY]VS[HNLZVMZL]LYHS[OV\ZHUK]VS[ZHUKKLZ[Y\J[P]LPUK\JLK
currents (damage to electrical and electronic equipment, interruption
of operation)
Protection against the effects of lightning is based essentially on:
JH[JOPUNHUKKPZJOHYNPUN[OLJ\YYLU[[VLHY[O
[OL\ZLVM]VS[HNLZ\YNLWYV[LJ[VYZ
[OLWHZZP]LWYV[LJ[PVUVM[OLPUZ[HSSH[PVU
Passive protection (poor, good) designates the part of the protection
provided by the structure and the configuration of the installation itself
(neutral earthing system, area, level of equipotentiality, etc.)

039 63

Dimensions (p. 64)


Technical characteristics (p. 65)
Pack

Cat. No.

Voltage surge protector for telephone lines and


data networks
Recommended for complete protection of installations already equipped
with low voltage
V.S.P. on power lines (standard IEC 60364)
For protection of: telephone, fax, modem, etc.,
connected to the incoming telephone line, against
overvoltages of atmospheric origin
Connected in series with the telephone line
Provided with a status indicator
NYLLU!Z\YNLWYV[LJ[VYVWLYH[PVUHS
VYHUNL!Z\YNLWYV[LJ[VYULLKZYLWSHJPUN
Conform to standards EN 61643-21 and
IEC 61643-21
Imax: 10 kA and In: 5 kA (8/20)

1
1

038 28
038 29

Un

Up

(V)

(V)

Analogue (RTC and ADSL)


Digital (signal lines, current loops)

170
48

260
100

Signalling auxiliaries for low voltage V.S.P.

039 56

For 2-pole module V.S.P.

039 57

For 3-pole module V.S.P.

039 58

For 4-pole module V.S.P.

Decoupling inductors for low voltage V.S.P.


Enable coordination between 2 V.S.P. in the same board, when minimum
distance to insure proper
V.S.P. coordination can not be respected
For multipole voltage surge protectors,
each conductor (including the neutral conductor) must be equipped with one
decoupling inductor

1
1

039 62
039 63

Module for circuit 35 A - 500 V


Module for circuit 63 A - 500 V

Voltage surge protectors and regulation


Voltage surge protector enable:
WYV[LJ[ZLUZP[P]LKL]PJLZHNHPUZ[KPYLJ[HUKPUKPYLJ[LMMLJ[ZVMSPNO[UPUN
[VSPTP[OHYTM\SJVUZLX\LUJLZVUWLYZVUZLJ\YP[`
[VPUZ\YL[OLJVU[PU\P[`VM^VYR
1 - Product standards EN 61643-11 and IEC 61643-1
Characterize voltage surge protectors in two main levels (types):
EN 61643-11
IEC 61643-1
VDE 0675-6 (1)
Type of wave
Main characteristics

With changeover microswitch 2 A - 250 V


Mounted onto the base of the surge protector
(except Cat. No. 039 10)
1

Protection against lightning effects

Type 1 (T1)
Class I (T1)
Class B
10/350 s
Iimp (10/350)
In (8/20)

Type 2 (T2)
Class II (T2)
Class C
8/20 s
In, Imax

(1) German standard VDE replaced by European standard EN 61643-11

2 - Installation standards: IEC 60364 (or equivalent electric national


standards)
According to articles 443 and 534, the use of VSPs is required in new or
renovated buildings in the following cases:
I\PSKPUNZLX\PWWLK^P[OSPNO[UPUNJVUK\J[VYZ![`WL=:7Z
I\PSKPUNZ^P[OV]LYOLHKWV^LYZ\WWS`PUJSHZZ(8NLVNYHWOPJaVULZ
ZLLTHWILSV^!YLKaVULZ![`WL=:7Z^P[O0UR(
I\PSKPUNZ^P[OTLKPJHSZLY]PJLZVYLX\PWWLK^P[OZHML[`Z`Z[LTZMPYL
L[JPUJSHZZ(8NLVNYHWOPJaVULZ![`WL=:7Z^P[O0UR(
The use of VSPs is also strongly recommended in mountain areas, close
to reaches of water or dominating structures (buildings, trees, etc.), in the
cases of line end installations or installations located less than 50m from
buildings equipped with lightning conductors (2)
When VSPs are present on the power circuit, it is strongly advised to
install a VSP on the communication circuits (telephone or data lines)
(2) Lightning conductors: external protection of buildings against direct lightning impacts

Choice of the level lightning protection

Number
of modules

2
4

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

65

voltage surge protectors (continued)

Technical characteristics

Installation

Voltage surge protectors for power lines

Voltage surge protectors cascading (multi-level protection)

Networks: 230/400 VA - 50/60 Hz


Degree of protection: IP 20
Operating temperature: -10 C to +40 C
Storage temperature: -20 C to +70 C

Beyond the standards requirements:


[OLJVZ[VM[OLJVUZLX\LUJLZVMLX\PWTLU[\UH]HPSHIPSP[`
[OLUH[\YLVM[OLLX\PWTLU[[VILWYV[LJ[LK0;LSLJ[YVUPJZL[J
[OLZP[\H[PVUVM[OLI\PSKPUNZWYV_PTP[`VYUV[VMHI\PSKPUNLX\PWWLK^P[O
a lightning conductor),
[OLWV^LYZ\WWS`UL[^VYR
are all situations that justify the installation of VSPs.
However, the efficiency of protection against overvoltages cannot be
optimally ensured with a single VSP.
This is why Legrand recommends combining several VSPs in cascade with
different protection levels, from the first panel as far as the device to be
protected (proximity protection of sensitive devices).
An installation will be all the more efficient if, beyond Class I and II VSPs, it
comprises proximity VSPs (Class III) on sockets supplying sensitive devices
(IT, electronic, etc.).

Type 2 V.S.P.
(class II)

High
protection
(H)

Increased
protection
(I)

Standard
protection
(S)

039 20/21/22/23

039 30/31/32/33

039 40/41/43

Neutral earthing system

TT - TN - IT

TT - TN - IT

TT - TN

Max. steady state


voltage (Uc)
Max.
Iimp (10/350)
discharge
Imax (8/20)
current
Nominal discharge
current
In (8/20)
Protection level (Up)
at In
at 5 kA
UT
Associated protection
DX, DX-H, DX-L
C curve
Max. terminal capacity
rigid conductor
exible conductor

440 VA

440 VA

320 VA

Cat. No.

10 kA

70 kA

40 kA

15 kA

20 kA

15 kA

5 kA

2 kV; 20 kA
1.5 kV; 5 kA
440 V

1.8 kV; 15 kA
1.3 kV; 5 kA
440 V

1.4 kV; 15 kA
1.2 kV; 5 kA
440 V

40 A

20 A

20 A

25 mm2
16 mm2

Main
board

Secondary
board

Without lightning conductor:


type 2 V.S.P.
H protection

With lightning conductor:


type 1 V.S.P.(mandatory)
H, I or S protection

Type 2 V.S.P.
I or S protection

Voltage surge protectors for telephone lines


Degree of protection: IP 20
Operating temperature: -10 C to +40 C
Storage temperature: -20 C to +70 C

Proximity
protection

Analog
038 28

Digital
038 29

Minimum voltage (Un)

170 V

48 V

Protection level (Up)

260 V

100 V

Nominal current (In)


Max. terminal capacity
exible/rigid

Mosaic or
P = Cliane
or similar

5 kA
0.5 to 2.5 mm2

Associated protection
The supply circuit of the VSP must be protected against short-circuits
and overloads by its associated disconnector (MCB) in accordance with
discrimination rules.
TT earthing systems, and V.S.P.: V.S.P. always installed downstream a
residual current device (RCD)

For the voltage surge protector to perform its function as well as possible,
it must be installed:
PUWHYHSSLS
RLLWPUNHZZOVY[HJVUULJ[PVUSLUN[OHZWVZZPISLIL[^LLU[OL
phase-neutral terminal block and the PE or PEN terminal block
PUHJJVYKHUJL^P[O,4*LSLJ[YVTHNUL[PJJVTWH[PIPSP[`Y\SLZ!
avoid the loops of conductors, fix the cables against metal
conductive parts

66

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

voltage surge protectors (continued)

Connection principles (continued)

2 - Voltage surge protector in TT system

3 - Voltage surge protector in IT system


Recommended cross-sections for conductors linking voltage
surge protectors

H level

Cross section
mm2
16

H level

Cross section
mm2
16

I level

10

I level

16

S level

S level

16

Type 2 V.S.P.

Type 1 V.S.P.

Minimum distances between voltage surge protectors


Upstream V.S.P.

Downstream V.S.P.

Distance (m)

S level

type 1

E (S)

type 2

8 (10)

H level

type 2

S (P)

type 2

8 (10)

I level

type 2

S (P)

type 2

4 (6)

S level

type 2

type 2

Installation for telephone lines


Protection of a telephone line
<WZ[YLHT[OLJVTT\UPJH[PVUKPZ[YPI\[PVUIV_

Installation of V.S.P. in the same board with decoupling inductors


When distances cannot be respected please use decoupling inductors,
installed as follows
CatNo. 039 62 or 63
L
N

+V^UZ[YLHT[OLJVTT\UPJH[PVUKPZ[YPI\[PVUIV_
- Analogue or digital
1st level

2nd level
(type 2 V.S.P.)

PE

1 - Voltage surge protector in TN system

- Digital

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

67

power contactors

NEW

from 16 A to 63 A

041 16

041 23

041 24

041 31

041 47

040 78

Dimensions (p. 70)

Conform to IEC/EN 61095


Space for power supply busbar on top (up to 25 A)
Pack

Cat. No.

I max

coil

Power contactors with 24 V


2-pole - 250 V

041 14

Pack

Cat. No.

2-pole - 250 V

Type
Number
of contact of modules

16 A

N/C + N/O

24V

I max

coil (continued)

Power contactors with 230 V

041 29

25 A

Type
of contact

Number
of modules

2 N/C

4 N/O

4 N/C

2 N/O + 2 N/C

230V

041 16

25 A

2 N/O

4-pole - 400 V

24V

4-pole - 400 V
1

041 17

25 A

4 N/O

24V

041 31

25 A

041 32

25 A

230V

coil and handle

Power contactors with 24 V

230V

Manual override for test and repair function, carried out via the
handle
Permanent "ON" or "OFF" without automatic reset

2-pole - 250 V
I max

041 23

25 A

040 73(1)

63 A

041 24

4-pole - 400 V
1

040 74(1)

Type
Number
of contact of modules

24V

2 N/O

2 N/O

4 N/O

041 33

230V

coil and handle

Power contactors with 230 V

25 A
63 A

25 A

4 N/O3

24V

Manual override for test and repair function, carried out via the handle
Permanent "ON" or "OFF" without automatic closing of the contactor

coil

Low noise power contactors with 230 V


2-pole - 250 V
1

041 49

I max

Type
Number
of contact of modules

25 A

2 N/O

230V

coil

2-pole - 250 V
I max

041 47

25 A

040 68(1)

40 A

040 75(1)

63 A

040 76(1)

63 A

040 69(1)

040 77

Power contactors with 230 V


2-pole - 250 V
4

041 26

I max

Type
Number
of contact of modules

16 A

N/C + N/O

230V

3-pole - 400 V

041 58

25 A

230V

2 N/O

230V

230V

Type
of contact

Number
of modules

2 N/O

2 N/O

2 N/O

2 N/C

3 N/O

3 N/C

40 A
230V

(1)

63 A
4-pole - 400 V

10

041 48

4 N/O

040 70

(1)

25 A
40 A

4 N/O

040 78 (1)

63 A

4 N/O

040 79

63 A

4 N/C

230V

230V

(1) Handle can be accessed once the blanking plate has been removed

68

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

power contactors

power contactors

NEW

from 16 A to 63 A (continued)

from 16 A to 63 A

Technical characteristics
YH[LKPTW\SZP]LYLZPZ[HU[J\YYLU[<PTW!R=
TLJOHUPJHSSPMLPUJ`JSLZVMVWLYH[PVUZ!6 cycles
[LTWLYH[\YL!
- operation: - 25 C to + 40 C
- storage: - 40 C to +70 C

Protection of contactors against short-circuits conforming


to IEC EN 61095, conditional short-circuit current Iq = 6 kA
MCB or gG fuse, rating:
(MVY(YH[PUN
(MVY(YH[PUN
(MVY(YH[PUN
(MVY(YH[PUN
s#ONTROLCOILCONSUMPTION
041 85

041 83

Power contactors 16 A and 25 A

040 85

Pack

Cat. No.

Maximum 2 auxiliary devices per contactor


Fitted on left-hand side of contactor
I max.

041 85

Voltage

5A
250 V
For 2 module contactors 25 A

Changeover
switch

Number
of modules

N/C + N/O

0.5

Maximum 2 auxiliary devices per contactor


Fitted on left-hand side of contactor
I max.

041 83

Changeover
switch

Number
of modules

N/C + N/O

0.5

Voltage

Changeover
switch

Number
of modules

250 V

N/C + N/O

0.5

Voltage

5A
250 V
For 40 and 63 A contactors

Maximum 1 auxiliary device per contactor


Fitted on left-hand side of contactor
I max.

040 85

5A

230 VA

Nominal current

16 - 25 A

25 A

25 A

16 - 25 A

16 - 25 A

Type of contact

N/O + N/C
2 N/C

4 N/O

2 N/O

N/O + N/C
2 N/O
2 N/C

Signalling auxiliaries for contactors


Auxiliary changeover switch
Used to signal the position status of the contacts on the product to which
it is connected
For 1 module contactors 16 A to 25 A

230 VA
low noise

24 VA

Control voltage

Number of modules
Holding
Inrush

2 N/O + 2
N/C
4 N/O
4 N/C
2

200 mA
970 mA

300 mA
300 mA

6 mA
55 mA

20 mA
90 mA

20 mA
200 mA

Power contactors 40 A, 63 A
24 VA

Control voltage

230 VA

Nominal current

40 and
63 A

40 and
63 A

40 and
63 A

40 and
63 A

Type of contact

2 N/O

4 N/O

2 N/O
2 N/C

2
250 mA
1750 mA

3
270 mA
1500 mA

2
15 mA
150 mA

3 N/O
4 N/O
4 N/C
3
30 mA
200 mA

Number of modules
Holding
Inrush

s2ECOMMENDATIONS
Derating of contactors mounted in modular boxes
if the internal temperature is > 40 C
Contactor rating
Ie = 16 A
Ie = 25 A
Ie = 40 A
Ie = 63 A

40 C
16 A
25 A
40 A
63 A

50 C
14 A
22 A
36 A
57 A

60 C
12 A
20 A
32 A
50 A

70 C
10 A
18 A
29 A
45 A

Install a spacing unit every two contactors (Cat. No. 044 40 or 044 41)
s-AXCONNECTIONCROSS SECTIONINMM2
Type of conductor

Ratings ) 25 A

Ratings 40
and 63 A

Rigid
Flexible
Flexible with single ferrule
Flexible with double ferrule

1 x 62 or 2 x 2.52
1 x 62 or 2 x 2.52
1 x 62
2 x 42

1 x 252 or 2 x 102
1 x 252 or 2 x 102
1 x 162
2 x 162

Cross reference list old range / new range


Old range
Cat. No.

New range
Cat. No.

Designation

040 33

041 14

16 A - 24 V - N/C + N/O

040 41

041 16 (1) / 041 23 (2)

25 A - 24 V - 2 N/O

040 43

041 17 (1) / 041 24 (2)

25 A - 24 V - 4 N/O

040 38

041 26

16 A - 230 V - N/C + N/O

040 49

041 58 (1) / 041 47 (2)

25 A - 230 V - 2 N/O

040 52

041 49

25 A - 230 V - 2 N/O low noise

040 50

041 29

25 A - 230 V - 2 N/C

040 53

041 31 (1) / 041 48 (2)

25 A - 230 V - 4 N/O

040 54

041 32

25 A - 230 V - 4 N/C

040 55

041 33

25 A - 230 V - 2 N/C + 2 N/O

041 85
040 85
041 83
040 85
(1) Without handle

Auxiliary changeover switch for 1


module 16 and 25 A contactors
Auxiliary changeover switch for 2
modules 25 A contactors
Auxiliary changeover switch
for 40 A and 63 A contactors

(2) With handle

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

69

Computer programmable time switch

Computer programmable time switch

DIN rail mounting

DIN rail mounting

Technical data
Type

Alpha Rex
D21

No. of modules (17.5 mm)


No. of channels

Alpha Rex
D22
2

running reserve

6 years

switching step

1 min
1 min

min. switching time

0,2 sec/day

accuracy
switching capacity
RESISTIVE6^COSs=1

incandescent lamps 230 V

8 A~

INDUCTIVE6^COSs=0,6

10 A~
1 SPDT

contact
047 73

16 A~

2 SPDT

56

programs1)
pulse start times

84
min.1 sec
max. 59 min,

047 61

pulse duration

59 sec

operating temperature

20 C

+55 C

IP20
(1) A program consists of an ON and an OFF time and the assigned days.
protection

AlphaRex Series
According to VDE 631-1 and 631-2-7, IEC 60 730-1 and 60 730-2-7,
EN 60 730-1 and 60 730-2-7
Ideal for school bells
Fast programming with selection of pre-set groups of days and individual
selection of days
Easy programming with PC using Legrand software and data key
Program consists of ON and OFF time with assignment to certain days
Backup possible on data key
With additional functions:
- holiday program
- random function
- pulse function (only 1 channel) with pulse duration of 1sec up to
59 min, 59 sec. and 84 start times
- hour counter for max. 65 535 hours.
Background lighting for display and buttons
Running reserve of 6 years for date and time
Programs are stored in a EEPROM
Programs are shown as a weekly matrix on the display
Automatic summer-/wintertime change (daylight saving)
Precision +/ 0,2 sec/day
Manual switching
Lead sealable cover, even with inserted data key

Wiring Diagram

AlphaRex D21

AlphaRex D22

Easy Programming
Pack

Cat. No.

AlphaRex D21

047 61

Weekly time switch, 1 channels


230 V, 50/60 Hz
1 changeover (SPDT) 250 V/50 Hz,
16 A~ cos 1
56 programs
min. switching time: 1 min.
switching stem: 1 min.

047 71

Weekly time switch, 2 channels


230 V, 50/60 Hz
2 changeover (SOPDT)250 V/50 Hz,
16 A~ cos 1
56 programs (28 per channel)
min. switching time: 1 min.
switching stem: 1 min.

047 72

Data key
Transfer data into time switch
PC programmable
Can also be used as a backup

047 73

USB-adapter
To read and write data keys on a PC
Software and key 04772 included
Connection via USB-port
System requirements: Windows2000,
WindowsME, WindowsXP and
Windows98 second Edition,
0 MB free disc space
Serial adapter on demand

The data key makes work even more convenient. You can set up the program
easily on your PC and then save it on your data key. With the Legrand software and the adapter it is a piece of cake.
Created programs can easily be saved, edited, managed and used.

AlphaRex D22

70

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

Digital weekly time switch

Digital time switch

DIN rail mounting

DIN rail mounting

Technical characteristics
Type
Channels

D21

D22 plus

2
6 years

Running reserve

1 min

Min. switching time

+/-1 s/d

Accuracy
Switching capacity
Res. cos = 1

16A

Incad. lamps

5A

Ind. cos = 0,6

8A
changeover
(SPDT) 16A

Contact
Max. programs

28

14 channel

Operation temp.

-20 C - +55 C

Storage temp.

-20 C - +60 C
IP20

Protection
example:
1. prog.: ON 07:00h
2. prog.: ON 16:00h
3. prog.: ON 10:00h

OFF 08:15h Mon-Fri


OFF 20:15h Mon-Sun
OFF 15:15h Fri

CH1
CH2
CH1+2

Wiring Diagram

6047 74

According to EN 60730-1 and EN 60730-2-7


Digital weekly DIN rail mounting time switch
1 program consists of 1 ON and 1 OFF time and the allocation of any day
of the week or a combination of days and the selected channel (2 channel
version).
Additional features:
- manual override (ON/OFF): permanent ON or OFF
- automatic override (ON/OFF): actual program will be inversed
(ON->OFF, OFF->ON) till next programmed ON time
- automatic changing of summer/winter time
- running reserve of 6 years
Pack

Cat. No.

MicroRex D21 Plus


1 channel

1
1

6047 74 230V 50/60Hz


6047 75 24V AC/DC

MicroRex D21 Plus

MicroRex D22 Plus

MicroRex D22 Plus


2 channel
1
1

6047 77 230V 50/60Hz


6047 78 24V AC/DC
Dimensions

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

71

Digital weekly time switches

Digital time switches

for DIN rail

for rail

Technical Data
Cat. No.
037 05

Supply voltage 120/230V + 10% /- 15%


Frequency 50/60 Hz
Switching
capacity:
cos = 1 16A
cos = 06 13A
Contact 1 changeover switch
Min. prog. time 1 minute
Accuracy 1 second / day at 25 C
Working reserve 6 years
IP rating IP 20
Operating temp. -10 C + 55 C

Dimensions
Single channel
D11

1
0

037 05

2
123456 7

12
24

D11 time switch - EcoRex D11


Conform to EN 60730-1 and EN 60730-2-7
Supply voltage: 120-230 V +10% 15% 50/60 Hz
Working reserve: 6 years
Accuracy: 1second per day
LCD digital display
Mount on DIN rail EN 50022
Programmable for 1 minute minimum
Programming possibilities:
Capability of 28 programs
1 program consists of 1 on and 1 off time and the allocation
of any day
of the week or a combination of days
Combination of days: Mon Fri (1-5), Mon Sun (1-7)
Any days
1. Prog.
2. Prog.
3. Prog.

of the week free programmable example:


on 7:00 off 8:15 Mon Fri
on 16:00 off 20:15 Mon Sun
on 10:00 off 16:15 Fri (5)

Automatic summer/winter setting


Cat. No.

037 05

72

ON

5
4

86 x 17.5mm

Wiring diagram
Single channel
D11

Manual advance/override (ON/OFF)

Pack

OFF

D11 1 module - Single channel


1 channel 16 A 250 V cos = 1

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

Rex - digital annual time switches


AlphaRex DY64

PRE-PROGRAMMABLE
TIME SWITCHES

>>>

Easy to
program
Store and transfer data easily using a PC
and datakey

047 70

According to VDE 631-1 and 631-2-7, IEC 60 730-1 and 60 730-2-7, EN 60


730-1 and 60 730-2-7
with text based programming concept
Selectable languages: English, German, French, Italian, Spanish and
Dutch
fast programming due to selection of pre-set groups of days Mo-Su, and
individual selection of days
easy programming with PC using Legrand software and data key
a program consists of an ON and OFF time and their assignment to
certain days
Backup on data key possible
84 programs per channel possible:
- 28 weekly/astronomical programs
- 28 yearly programs
- 28 exceptional programs
shortest possible program: 1sec
background lighting for display and buttons
running reserve of 5 years for date and time
programs are stored in a EEPROM
programs are shown as a weekly matrix on the display
automatic summer-/wintertime change (daylight saving)
Precision +/ 0,2 sec/day or according to frequency
manual override switches (ON/OFF/AUTO) for every channel on the
frontside
manual switching
lead sealable cover, even with inserted data key
Calculation of sunrise and sunset by programming date, time and local
coordinates.
No light sensor needed!
The switching ON and OFF times (astro function) can be adjusted
asymetricaly for +/- 120 minutes.
The control input enables the activation of the time switch irrespective to
the program. (only for channel 1)
Possible to create a cyclical repetitive program. (only for channel 1)

AlphaRex
to PC

Transfer data from:

PC to
AlphaRex

AlphaRex
to AlphaRex

Data Key:
transfer data
portable storage device
can also be safely stored in the AlphaRex
secure back up
Data key 047 81 can be used only with
AlphaRex DY64

AlphaRex DY64

Pack

Cat. No.

047 70

Data key for DY64


CAUTION: 047 81 only used with 047 70
047 82 Replacement battery
6047 78 24V AC/DC

Annual time switch, 4 channels


120/230V, 50/60Hz

Accessories
1
1

047 81

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

73

Rex - digital time switches


AlphaRex DY64

The AlphaRex DY64 offers


3 different types of programming:
Weekly Program
This menu item is provided for the simple input
of programs which are to be repeated weekly
(such as switching of lights and boilers). A weekly program
consists of an ON time, an OFF time
and the associated ON and OFF days.
MON TO SUN: the days of the week are already assigned
and you only need to set the ON and OFF times. This is used
where the same program
is to be executed on every day of the week.

INDIVIDUAL: you can assign the ON and OFF times to any


desired days. This is used where the same
program is to be executed only on certain days
of the week or different programs are to be executed on the
various days.

Yearly Program
This menu item permits the input of (additional)
annual programs which are to be executed only during a
specified period. These programs and the weekly programs
of the same channel are ORed together
as described above. The period during which a
program is to be executed is defined by entering
a start date and an end date.

Option INDIVIDUAL: the exception program is active from


00:00 hours on the start date to 24:00 hours
on the end date. During this period, the output
of the related channel switches only as defined
in the exception program.

Option PROG ON: the exception program is active from the


ON time on the start date to OFF time
on the end date. During this period, the output
of the channel is permanently on.

Option PROG OFF: the exception program is active from


the ON time on the start date to OFF time
on the end date. During this period, the output
of the channel is permanently off.

Cycle function for channel 1


Instead of its STANDARD function, the output
of channel 1 can be switched on and off cyclically.
The available parameters are the PERIOD and the SWITCH
ON time within this period.
Program
channel
1,or
control
signal S

15:00:00

15:10:00

Channel
1
relay

Type

Number of channels

Power reserve

Exceptional Program

1 sec

Shortest switching time

1 sec

Switching capacity
Ohmic 230 V~cos =1
Filament lamp 230 V
Inductive 230 V~cos =0,6
Switch output

The option ONCE should be selected if the exception


program is to be activated only during a single period (e.g.
vacation period), but the start and end dates
of this period are different in each year.

Option MON TO SUN: the exception program


is active from 00:00 hours on the start date to 24:00 hours
on the end date. During this period, the output of the related
channel switches only as defined
in the exception program.

5 years

Switching increment

Accuracy

74

Alpha Rex
6

The option ONCE should be selected if the additional


program is to be executed only during a single period (e.g.
vacation period), but the start and end dates
of this period are different in each year.

Programs1)
Control input with delay-time
Operating temperature
Type of protection

0,2 s/day/ or frequency

16 A~
8 A~
10 A~
4 SPDT
3 x 4 x 28 (336)
0 min
23h 59min
20 C + 55 C
IP20

Dimensions (mm)

047 70
M

120V/230V 50/60Hz
R6a -20T

2
ON
AUTO
OFF

ON
AUTO
OFF

83

The option EVERY YEAR should be selected


if the exception program is to be activated
for the same period in each year (e.g. Christmas,
national holidays, birthdays, etc.).

0:04:00

No. of pitch units of 17.5 mm

0:04:00

Technical data

The option EVERY YEAR should be selected if the additional program is to be executed during the same period of each
year (e.g. Christmas, national holidays, birthdays, etc.).

15:30:00
0:10:00
15:32:00

0:04:00

The weekly and annual programs defined


for a channel are not executed as long as an extra program is active. However, other exception programs will be
executed while an exception program is active. The various
exception programs are ORed together
as described above. (see OR function 3a)

15:20:00
0:10:00

0:10:00

4
ON
AUTO
OFF

ON
AUTO
OFF

120V/230V~50/60Hz

N S Ch1

66

107,7

047 70
M

120V/230V 50/60Hz
R6a -20T

2
ON
AUTO
OFF

ON
AUTO
OFF

4
ON
AUTO
OFF

ON
AUTO
OFF

120V/230V~50/60Hz

N S Ch1

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

AlphaRex Astro

electro-mechanical time switches

programmable time switches

for DIN rail

037 55
037 21

037 40

037 44

047 64

According to VDE 631-1 and 631-2-7, IEC 60 730-1 and 60 730-2-7, EN 60


730-1 and 60 730-2-7
with text based programming concept
fast programming due to selection of pre-set groups of days
Mon-Sun, Mon-Fri, Sat-Sun and individual selection of days
easy programming with PC using Legrand software and data key
a program consists of an ON and OFF time and their assignment
to certain days
Backup on data key possible
with additional functions:
- holiday program
- hour counter for max. 65 535 hours.
background lighting for display and buttons
running reserve of 6 years for date and time
programs are stored in a EEPROM
programs are shown as a weekly matrix on the display
automatic summer-/wintertime change (daylight saving)
Precision +/ 0,2 sec/day
Manual switching
lead sealable cover, even with inserted data key
Calculation of sunrise and sunset by programming date,
time and local coordinates.
No light sensor needed!
To save energy, a switching off at night is programmable.
The switching On and OFF times can be adjusted asymetricaly
for +/- 120 minutes.
The control input enables the activation of the time switch irrespective to
the program. (NOT D22 Astro!)
Pack
1
1

Cat. No.

AlphaRex D21 Astro

047 64
047 66

weekly time switch, 1 channel


230V, 50/60Hz
24V, 50/60Hz

047 67
047 69

weekly time switch, 2 channel


230V, 50/60Hz
24V, 50/60Hz

Supply voltage: 230 V~+10% 15%


Accuracy: 5 minutes per day
3- pos. switch: on-off-auto
Mount on DIN rail EN 50022
Pack

Cat. No.

1 module - 1 channel
24 hour Programme

1 segment = 15min, Accuracy 5mm


1

037 30

 8;^P[OOY^VYRPUNYLZLY]L/a

T11 without working reserve 50 Hz

 4PUPT\TZ^P[JO[PTLOV\YZ56*VU[HJ[8>

3 modules - 1 channel
24 hour Programme
Minimum switch time 45min - changeover switch
1

037 52

 8;^P[OOY^VYRPUNYLZLY]L/a

T31 without working reserve 50 Hz


Weekly Programme
Programmable for 6 hours minimum at 2 hourly intervals

 4PUPT\TZ^P[JO[PTLOV\YZJOHUNLV]LYZ^P[JO8>

AlphaRex D22 Astro


1
1

Microlux D
1

037 21

Light sensitive weekly time switch


230 V, 50/60Hz
running reserve: 100H
Supplied with photoelectric call in plexo
weather proof box

Remark:
The AlphaRex Astro can be programmed using the datakey
04772 and the programming software (see page 146)

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

75

REX ASTRONOMICAL TIME


SWITCHES

>>>

electro-mechanical time switches


for DIN rail - Technical data

Easy control
Easy Control of lights based on the of sunrise and
sunset, with no need of installing a light sensor!

MicroRex
Type
Cat. No.

T11

QT11

QW11

037 30

037 40

037 44

Supply voltage

230 V~ +10% 15%

Frequency

50 Hz

50/60 Hz

Switching
capacity for
cos = 1

50/60 Hz

16 A

Contact

On/off

Working reserve

None

100 hours

100 hours

Min. switching
time

15 minutes

15 minutes

2 hours

Interval

15 minutes

15 minutes

2 hours

Operating temp.

10 C + 55 C

Wiring diagram

Dimensions
60
1 7 5

M
~

44

2
3
4
5

U2

45

m ax.86

U1

MicroRex
Type

T31

QT31

037 52

037 53

QW31
Cat. No.

Supply voltage

230 V +10% 15%

Frequency

50 Hz

50/60 Hz

Switching
capacity for
cos = 1

Changeover switch

Working reserve

76

100 hours

100 hours

15 minutes

2 hours

Interval

30 minutes

4 hours

10 C + 55 C

Operating temp.

Dimensions

Wiring diagram
60

53

M
~

44

U1

U1 U2 1 4 2

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

45

None

Min. switching
time

Max. 90

50/60 Hz

16 A

Contact

Comfort and safety:


The time switch calculates the daily times
of sunset and sunrise. At sunset the
AstroRex will switch the lights ON and at
sunrise the AstroRex will turn the lights
OFF.
Energy saving:
program an OFF and an ON time at night
Typical applications:
shop window illumination
billboard illumination
private and public buildings

037 55

U2

electro-mechanical time switches

electro-mechanical time switches

surface mounting

surface mounting Technical data

MaxiRex
Type

Cat. No.

QT

497 50

EconoRex

497 54

QW

497 52

BTAP
499 81

497 56

499 81
230 V+10% 15%

Supply voltage

50/60 Hz

50 Hz

Frequency

50 Hz

50/60 Hz

50 Hz

Switching capacity:
cos = 1

16 A

cos = 06

10 A

8A

1 000 W

1 000 W

incand. lamp

16 A

0499 81
1 c/o

Contact

1 c/o

1 c/o SPDT

SPDT

1499 81
1 n/o

Working reserve

None

Min. switching

100 hrs

None

100 hrs

None

10 mins

1 hrs

15 mins

20 mins

2 hr

15 mins

time
497 54

Interval

IP 20

IP rating

Conform to EN 60730-1 and EN 60730-2-7


Supply voltage: 230 V~+10% 15%
3 position changeover switch
With 72 x 72 mm display to DIN EN 50022 Part C

497 50
 

Dimensions
MaxiRex

TM

With manual override


24 hour - 1 channel
Programmable for 20 minutes at 10 minute intervals
Accuracy: 5 minutes per day
Without working reserve 50 Hz - T

4 4 5
34
20

72
4 5

>P[OOY^VYRPUNYLZLY]L/a8;
7 day - 1 channel

1
1

Pack

497 52
 

Programmable for 2 hours at 1 hour intervals


Accuracy: 30 minutes per day
Without working reserve 50 Hz - W
>P[OOY^VYRPUNYLZLY]L/a8>
69

Cat. No.

044 09 Fixing accessory for maxirex time switch


Adaptor forrail EN 50022

498 32 Frame for panel mounting

66
65

1
1

Maxirex

0 C + 55 C

72

Cat. No.

10 C + 60 C

Storage temp.
Operating temp.

110

Pack

IP 40

3 3 5

Mounting of time switches


s0ANEL-OUNTING
498 32

s/NDINRAIL
with accessory

044 09

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

77

20A time switch

20A time switch

for DIN-Rail mounting and wall mounting

Analogue for DIN-Rail mounting and wall mounting

6499 18

Type

MaxiRex4

No. of channels

Switching capacity
Cos = 1
incandescent
ind. Cos = 0,6

20 A~
4 A~
10 A~

Minimum setting unit

10 min for daily


1 h for weekly

Minimum setting interval

20 min for daily


2 h for weekly

Operating temperature

-10 + 50

Protection modus

IP 53
(with plastic box)

6499 17

According to UL 9/7, IEC 60730-1, EN 60730-1, VDE 0631 part 1,


IEC 60730-2-7, EN 60730-2-7, VDE 0631 part 2-7.
Robust analogue daily and weekly time switch for DIN-Rail mounting, wall
mounting and for installation in plastic box (4 terminal version)
^P[OTHU\HSZ^P[JOVU(\[VTH[PJ
OHUKZJHUILTV]LKJSVJR^PZLHUKJV\U[LYJSVJR^PZL
20A MaxiRex 4 time switch

Pack

Cat. No.

6499 18

4T (230V 50Hz) without enclosure

6499 17

4TB (230V 50Hz) with IP53 enclosure

6499 15

8;=/a^P[OV\[WSHZ[PJIV_

6499 14

8;)=/a^P[O07LUJSVZ\YL

24 hour - without working reserve

24 hour - with 500 hr working reserve

Dimensions of programmable time switches

Econorex M TM

24 hour - 1 channel
Programmable for 15 minutes minimum at
15 minute intervals with retained pull out segments
Easily programmed, easily read by user
Just set actual time to pointer and pull out segments

Analogue time switches

Cat. No. 6499 14


100.6

70

51

for switch time

499 86

7HULSTV\U[PUN_TT48;>/^VYRPUNYLZLY]L

3
6

119.5

120

Panel mounting (72 x 72mm) MT, No working reserve

150.6

499 83

171.2

144.5

12
9

49

Contacts for MaxiRex

Contacts for EconoRex

U1

U2

Cover for 649 918 & 649 915

649 949

78

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

2 U1

U2

time switches and hour counters

Cat. No. 499 26


Contacts
M

2 3

4 5 6

Characteristics of hour counters

495 55

499 26

Hour counters
48 x 48 mm
AC current - design : 0...99999.99 hr
DC current - design : 0...999999.9 hr
IP 40 Panel flush mounting
Voltage supply:

- 50 Hz
- 50 Hz

495 52

24 V

Dimensions

495 55

240 V

48.5

495 60

12-36 VDC

32

Totalising hour counters (Din mounting)

0000123 h

45

50

45

Pack Cat. No.

046 94

Materials - front panel : transparent synthetic material


Type : 48 x 48 mm
Mounting : flush-mounting
Range: A.C. : 099999.99 hr/D.C. : 0999999.9 hr
Accuracy : A.C.:1/100e h/D.C.: 1/10e h
Reset : none
Size of numerals : 4 mm
Consumption : A.C. : 2 VA/D.C. : 0.65 W
Index of protection : IP 40
Operating temperature : 25 C to + 80 C
Weight: 110 g
Terminal connections : 2 x 1.5 mm2

Count the operating hours of a machine or an electrical device to


determine its exact operating time
Counter with numerical display
Capacity: 5 digits + 2 decimal places (1 unit = 1 hr)
Precision: 1/100th hour
Number
Consumption: 0.2 VA
of

046 94

046 91

- 50 Hz
24 V - 50 Hz

modules

230 V

2
2

Defrosting time switch


Time switch for short periods for control of defrosting, regularly repeated
switching of pumps, feed conveyors, sprinkler systems, periodic
lubrication of machines


(=JVZ $
IP 30
24 hour programme
The timer can repeat one or two settable short programmes within 24
hours
Shortest switching sequence
2.5 hours - up to 9 times
1 switching step = 1 segment = 30 min.
With two changeover contacts
Without working reserve

- 50 Hz

Voltage supply 230 V


1

499 26

KKT - Defrosting time from 10 to 60 minutes per contact

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

79

dimensions of LEXIC modular din-rail equipment

G
D

45

80

C
F

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

Notes

81

Distribution
cabinets and
consumer units

Distribution
cabinets,
enclosures
and
connection
Distribution
boards
(P. 85)

82

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

P. 84
Modular boxes

P. 85
Distribution boards
24P to 84P

P. 85
Supply busbars,
entry terminals

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

P. 86
Modular
distribution
blocks

83

modular boxes - IP30

modular boxes - IP30

surface mount - Din rail

surface mount - Din rail

Distribution box with 1 to 9 modules per row

013 04

Pack

Cat No.

013 08

Self-extinguishing: resistance to
incandescent wire 750C distribution boxes
IP30 - IK05
White RAL 9010
Cover directly clip shut and sealable
Capacity in modules
of 17.5 mm

10
10
10
5
1

013 01
013 02
013 04
013 06(1)
013 08(2)

1
2
4
6
(8 + 1)

x 30 x
x 50 x
x 90 x
x 128 x
x 190 x

47.5

72
72
74
74
83

Cat.No 013 08 with cover

Cat.Nos

013 01

30

72

140

120

10

013 02

50

72

140

115

25

013 04

90

74

160

130

45

013 06

128

74

160

125

80

013 08

190

83

180

130

120

14.5

(1) Supplied with Earth connector IP 2x 4x holes 1.5- 16mm2


(2) Supplies with Earth connector IP 2x 8x holes 1.5- 16mm2

84

103

Cat.Nos 013 01/02/04/06/08

Dimensions (mm)
Height x Width xDepth

140
140
160
160
180

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

Distribution Boards IP55


and Accessories

Connection accessories

049 14

049 26

049 05

049 44

Standard distribution
Pack

Prong-type supply busbars

Cat. No.

Universal single pole + neutral


Reversible: blue for neutral, black for live

Distribtution Boards
Pack

1
1
1
1
1
1

HPM0800L - 24
HPM0800L - 36
HPM1000L - 48
HPM1000L - 60
HPM1200L - 72
HPM1200L - 84

1
1
1
1
1
1

HPM0800L2425F
HPM0800L3625F
HPM1000L4825F
HPM1000L6025F
HPM1200L7225F
HPM1200L8425F

50
10

049 38 (1)
049 39

Double pole
1 row
Meter

3
10

049 40 (1)
049 41

Double pole balanced on 3 phases


1 row
6
Meter
28

40
10

049 42 (1)
049 43

Triple pole
1 row
Meter

4
19

30
10

049 44
049 45

Four pole
1 row
Meter

3
14

Protection
Protection of prongs
12 modules
Can be cut to length

40
20
20

049 89
049 90
049 91

20

049 05

For universal single pole + neutral


or single pole supply busbars
Cross section: 4 to 25 mm2 - IP 2X

Main Switch

20

049 06

For all supply busbars


Cross section: 6 to 35 mm2

6022 10
6022 11
6022 12
6022 13
6022 14
6022 15

2046 39

3 Pole 250A

Emergency Lighting Test Switch

Protection of supply busbar ends


For single pole/single pole + neutral
For double pole length 1 m and triple pole
For four-pole

Entry terminals

Technical characteristics

Modular E/L test switch (contactor not included)


Modular contactor 2pn/c 25A
Modular contactor 4pn/c 25A

Busbars
types
Single pole or
Single pole + neutral

External Dimensions

6
28

049 88

1
1
1
1
1
1

13
57

20

(red, white, blue)


250A Chassis for 17.5mm module MCBs 20kA 0.1S
24 Pole
36 Pole
48 Pole
60 Pole
72 Pole
84 Pole

6820 84
04129
04132

1 row
Meter

049 26
049 37

Chassis 3 Pole

1
1
1

number of
devices connected

20
10

Cat. No.
250 A Distribution Panels with 250A chassis
for 17.5mm module MCBs Escutcheon included
Without Main Switch
24 pole
36 pole
48 pole
60 pole
72 pole
84 pole
With 250A Main Switch
24 pole
36 pole
48 pole
60 pole
72 pole
84 pole

Max.
Length

Height
(mm)

Width
(mm)

Depth
(mm)

800
800
1 000
1 000
1 200
1 200

600
600
600
600
600
600

200
200
200
200
200
200

No
Poles

24
36
48
60
72
84

Distribution Board
Without
Main Switch
Cat. No
HPM0800L - 24
HPM0800L - 36
HPM01000L - 48
HPM01000L - 60
HPM01200L - 72
HPM01200L - 84

With
Main Switch
Cat. No
HPM0800L2425F
HPM0800L3625F
HPM1000L4825F
HPM1000L6025F
HPM1200L7225F
HPM1200L8425F

For 400A Distribution Boards


Please consult us

Double pole
Double pole
balanced on 3-phases
Triple pole
Four pole

Pack

20

1 row
Meter
1 row
Meter
1 row
Meter
1 row
Meter
1 row
Meter

Max.
Length Cross
Permissible current:
number in number section 1 central
2 power
of devices of 17.5 mm (mm2)
power
connected modules
supply point supply point
13
13
162
80
100
57
57
63
90
6
12
102
28
56
162
80
100
6
12
102
63
90
28
56
162
80
100
4
12
102
63
90
19
57
162
80
100
3
12
102
63
90
14
56
162
80
100

Cat. No

Clip-on blanking plate (pole fillers)

016 56

6.5 modules separable by single or half modules


(1 module 17.5 mm)
White RAL 9010

(1) Filled with end protection

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

85

modular distribution blocks


40 to 250 A

modular distribution blocks


40 to 250 A

Section for connecting rigid or flexible conductors


(with Starfix ferrules)
Distribution
Blocks

048 68

8.5

6 to 25

376 68 to 71

10

6 to 35

376 68 to 77

8.9

6 to 25

376 68 to 71

12

5.3

16 to 50

1.5 to 10

376 64 to 69

10

1.5 to 10

16 to 35

376 70 to 77

70 to 150

2.5 to 10

376 66 to 69

8.5

2.5 to 16

10 to 25

376 69 to 77

10 to 35

70 to 120

5.3

2.5 to 10

1.5 to 10

376 64 to 69

7.5

10 to 25

6 to 16

376 68 to
70/77

11

4.3

1.5 to 4

0.75 to 4

376 62 to 67

6 to 16

4 to 10

376 67/68/69

11

5.3

2.5 to 10

1.5 to 10

376 64 to 69

7.5

10 to 25

6 to 16

376 68 to
70/77

10 to 35

10 to 25

376 69/72/71

5.3

35 to 70

1.5 to 10

376 64 to 69

7.5

2.5 to 10

6 to 16

376 68/69/77

8.9

6 to 25

10 to 25

376 69/72

10 to 35

25 to 50

376 71 to
77/78

5.3

2.5 to 10

1.5 to 10

376 64 to 69

7.5

10 to 25

6 to 16

376 68 to
70/77

11

4.3

1.5 to 4

0.75 to 4

376 62 to 67

6 to 16

4 to 10

376 67/68/69

5.3

2.5 to 10

1.5 to 10

376 64 to 69

7.5

10 to 25

6 to 16

376 68 to
70/77

(mm)

048 67

6
4

048 71

Flexible conductors
with ferrules
Starx
ferrules
Cat. No.

Number

048 88

Rigid
conductors

Section
(mm2)

Cat. No.

048 68

048 77

Connections
per bar

Section
(mm2)

376 70 to 77

Technical characteristics (p. 87)


Standard distribution
Connection with or without Starfix ferrules
Self-extinguishing, according to EN 60695-2-11: 960 C on active part
supports
Pack

Cat. No.

Monobloc modular distribution blocks


Mounting on rail 4 or on plate with 2 screws
Supplied with insulated back plate and transparent protective front
cover. Each bar can be labelled using CAB 3.
Possible to add IP 2X terminal block (except Cat.No 048 77)

048 73

048 80

048 81

048 82

Double pole
Equipped with 2 bars
Isc
Rating
peak
(A)
(k)
5
10
5

048 81
048 80
048 82

40
100
125

Icw
(kA)

20
20
18

Number
of modules

3
4.5
4.5

6
4
8

Four pole

5
10
5
5
1
1

048 85
048 84
048 86
048 88 (1)
048 79 (1)
048 77

048 83

048 84

Equipped with 4 bars


40
20
100
20
125
20
125
14.5
160
27
250
42

3
4.5
4.5
4.2
8.4
14.4

6
4
6
8
10
9

Modular distribution blocks


Mounting on rail 4
Fitted with Lexic label holder
Can be joined together
Possibility of forming a four pole
distribution block by adding modules

048 85

048 86

048 88

048 71

048 83

160

27

048 73

250

60

10 to 35

10 to 25

376 69/77

5.3

2.5 to 10

1.5 to 10

376 64 to 69

8.5

10 to 35

6 to 25

376 68 to 71

35 to 70

35 to 70

376 77/78

1
048 79

Single pole
Rating
(A)
125

2
11

Isc peak Number


(k)
of modules
35
2

5.3

2.5 to 10

1.5 to 10

376 64 to 69

7.5

10 to 25

6 to 16

376 68 to
70/77

8.5

10 to 35

10 to 25

376 69/77

2.5 to 16

2.5 to 10

376 66 to 69

7.5

10 to 25

6 to 16

376 68 to
70/77

8.5

10 to 35

10 to 25

376 69 to 77

Distribution terminals

10

16 to 50

16 to 35

376 70 to
72/77

50 to 120

50 to 120

376 78

048 67

160 A - 6 outputs 25 mm flexible - Isc peak 30 k


Can be fitted directly onto downstream terminal
of DPX 125/160, Vistop 100/160 A and DX H 125 A

048 68

250 A - 4 outputs 35 mm2 flexible and 2 outputs 25 mm2 flexible - Isc


peak 36 k
Can be fitted directly onto downstream terminal of DPX 250/250 ER and
DPX-IS 250

048 77

(1) With short ferrule supplied for flexible connection 25 mm2

86

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

modular distribution blocks


40 to 250 A (continued)
Modular distribution blocks

Conform to EN 60947-1
Insulating voltage according to EN 60947-1 / IEC 60664-1: 500 V
Impulse voltage (Uimp): 8 kV - Degree of pollution: 3
Use in DC: without derating
Self-extinguishing 960 C on active parts supports

Single pole 125 - 160 - 250 A, Cat. No. 048 71/83/73

60
44

144

44
50

23

Four pole 40 - 100 - 125 A, Cat. No. 048 85/84/86/88

Cat. No.

Width
(mm)

048 80
048 81
048 82
048 84
048 85
048 86
048 88
048 77
048 79

70
105
140
70
105
105
140
160
179

101.5
45

49

39

23

Double pole 40 - 100 - 125 A, Cat. No. 048 81/80/82

104.5

Monobloc modular distribution blocks

Connection

86

88.5

125 A

250 A

36

36

Torque
3.5 Nm

44
50

160 A

Torque
3.5 Nm

Torque
24 Nm

10 Nm

23

Four pole 160 A, Cat.No 048 79

96.8

91.5

Cat.No 048 71

Cat.No 048 83

Cat.No 3

Distribution terminals, Cat. No. 048 67/68


160 A

250 A

44
50

25

45

10

75

150

85

Four pole 250 A, Cat.No 048 77


Self-extinguishing 960 C according to EN 60695-2-11
W

5.5
134.5

70.5
75

Use of IP 2X terminal blocks


Modular
distribution
blocks
048 80

Derating
Voltage
Rating
400 V

80 A

048 81

400 V

40 A

048 82

400 V

100 A

048 84

400 V

80 A

048 85

400 V

40 A

048 86

400 V

100 A

048 88

400 V

100 A

048 79

400 V

100 A

Some items sold separately


For pack quantity, please refer to numerical index pages
For trade price, please see your local HPM Legrand representative for the current price list

87

Vous aimerez peut-être aussi