Trabajo practico de transmisin en eat

Geometria de la lnea

--- 16 cards of disk file read into card cache cells 1 onward.
Alternative Transients Program (ATP), GNU Linux or DOS. All rights reserved by Can/Am user group of Portland,
Oregon, USA.
Date (dd-mth-yy) and time of day (hh.mm.ss) = 04-Sep-12 16:58:54 Name of disk plot file is linea500kv.pl4
Consult the 860-page ATP Rule Book of the Can/Am EMTP User Group in Portland, Oregon, USA. Source code date
is 16 September 2005.
Total size of LABCOM tables = 10223567 INTEGER words. 31 VARDIM List Sizes follow: 6002 10K 192K 900 420K
1200 15K
120K 10K 20K 720 2K 72800 510 90K 800 90 254 120K 100K 3K 15K 192K 120 60K 160K 600 210K 300
19 400
--------------------------------------------------+-------------------------------------------------------------------------------Descriptive interpretation of input data cards. | Input data card images are shown below, all 80 columns,
character by character
0
1
2
3
4
5
6
7
8
012345678901234567890123456789012345678901234567890123456789012345678901234567890
--------------------------------------------------+-------------------------------------------------------------------------------Comment card. NUMDCD = 1.
|C data:LINEA500KV.ATP
Marker card preceding new EMTP data case.
|BEGIN NEW DATA CASE
Compute overhead line constants. Limit = 120 |LINE CONSTANTS
Erase all of 0 cards in the punch buffer. |$ERASE
Pairs of 6-character bus names for each phase. |BRANCH IN___AOUT__AIN___BOUT__BIN___COUT__C
Request for metric (not English) units.
|METRIC
Line conductor card. 3.520E-01 7.550E-02 4 | 10.352 0.0755 4
2.154 -10.8 30.05 10.55 45. 45.
4
Line conductor card. 3.520E-01 7.550E-02 4 | 20.352 0.0755 4
2.154 0.0 30.05 10.55 45. 45.
4
Line conductor card. 3.520E-01 7.550E-02 4 | 30.352 0.0755 4
2.154 10.8 30.05 10.55 45. 45.
4
Line conductor card. 5.000E-01 3.190E+00 4 | 0 0.5 3.19 4
0.915 -9.05 39.3 20.8 0.0 0.0
0
Line conductor card. 5.000E-01 3.190E+00 4 | 0 0.5 3.19 4
0.915 9.05 39.3 20.8 0.0 0.0
0
Blank card terminating conductor cards.
|BLANK CARD ENDING CONDUCTOR CARDS
Frequency card. 2.000E+02 5.000E+01 5.380E+02 | 200.
50.
538.

Line conductor table after sorting and initial processing.


Table Phase Skin effect Resistance Reactance data specification Diameter Horizontal Avg height
Row Number
R-type R (ohm/km) X-type X(ohm/km) or GMR ( cm ) X (mtrs) Y (mtrs)
Name
1
1
.35200
.07550
4
.000000 2.15400 -10.575
16.825
2
2
.35200
.07550
4
.000000 2.15400
0.225
16.825
3
3
.35200
.07550
4
.000000 2.15400
11.025
16.825
4
1
.35200
.07550
4
.000000 2.15400 -11.025
16.825
5
1
.35200
.07550
4
.000000 2.15400 -11.025
17.275
6
1
.35200
.07550
4
.000000 2.15400 -10.575
17.275
7
2
.35200
.07550
4
.000000 2.15400
-0.225
16.825
8
2
.35200
.07550
4
.000000 2.15400
-0.225
17.275
9
2
.35200
.07550
4
.000000 2.15400
0.225
17.275
10
3
.35200
.07550
4
.000000 2.15400
10.575
16.825
11
3
.35200
.07550
4
.000000 2.15400
10.575
17.275
12
3
.35200
.07550
4
.000000 2.15400
11.025
17.275
13
0
.50000
3.19000
4
.000000
.91500
-9.050
26.967
14
0
.50000
3.19000
4
.000000
.91500
9.050
26.967
Matrices are for earth resistivity = 2.00000000E+02 ohm-meters and frequency 5.00000000E+01 Hz. Correction
factor =
1.00000000E-06
Blank card terminating frequency cards.
|BLANK CARD ENDING FREQUENCY CARDS
Request for flushing of punch buffer.
|$PUNCH
A listing of 80-column card images now being flushed from punch buffer follows.
===============================================================================
1234567890123456789012345678901234567890123456789012345678901234567890123456789
===============================================================================
C <++++++> Cards punched by support routine on 04-Sep-12 16:58:54 <++++++>
C **** TRANSPOSED Line calculated at 5.000E+01 HZ. ****
C LINE CONSTANTS
C $ERASE
C BRANCH IN___AOUT__AIN___BOUT__BIN___COUT__C
C METRIC
C 10.352 0.0755 4
2.154 -10.8 30.05 10.55 45. 45.
C 20.352 0.0755 4
2.154 0.0 30.05 10.55 45. 45.
C 30.352 0.0755 4
2.154 10.8 30.05 10.55 45. 45.
C 0 0.5 3.19 4
0.915 -9.05 39.3 20.8 0.0 0.0
C 0 0.5 3.19 4
0.915 9.05 39.3 20.8 0.0 0.0
C BLANK CARD ENDING CONDUCTOR CARDS
C 200.
50.
538.
$VINTAGE, 1
-1IN___AOUT__A
2.78958E-01 6.20427E+02 1.85782E+05 5.38000E+02 1
-2IN___BOUT__B
1.94548E-02 2.52006E+02 2.92553E+05 5.38000E+02 1
-3IN___COUT__C
$VINTAGE, -1,
=========< End of LUNIT7 punched cards as flushed by $PUNCH request >=======
Blank card ending "LINE CONSTANTS" cases.
|BLANK CARD ENDING LINE CONSTANT
Timing figures characterizing central processor (CP) solution speed. ---------------------------- CP sec Wait sec Real sec
Totals 0.000 0.000 0.000

Con los datos que se obtienen de la lnea de 500kv, se los emplea para determinar el modelo de Clark
Modo 1
r/l

Longitud de la lnea

1.94548E-02

52006E+02

2.92553E+05

5.38000E+02

Modelo de parmetros distribuidos , Clark, monofsico, por esta razn se modela con el modo 1
G=o , sin distorsion ,

Se alimenta a la lnea en vacio mediante una fuente continua de amplitud unitaria, las ondas de tensin antes y
despus de la lnea, son
3,0
2,5
2,0
1,5
1,0
0,5
0,0
-0,5
-1,0
0,00

0,02

(f ile linea500kv .pl4; x-v ar t) v :XX0002

0,04

0,06

0,08

0,10

v :XX0001

Double-Click here to set the title text!

2,0

1,6

1,2

0,8

0,4

0,0
0,0

0,1

(f ile linea500kv .pl4; x-v ar t) v :XX0002

0,2

0,3

v :XX0001

Para una lnea con distorsion , las ondas de tensin son:

0,4

0,5

0,6

2,0

1,5

1,0

0,5

0,0

-0,5

-1,0
0,00

0,02

(f ile linea500kv .pl4; x-v ar t) v :XX0002

0,04
v :XX0001

0,06

0,08

0,10

Vous aimerez peut-être aussi