Vous êtes sur la page 1sur 2

13200C

Uniaxial

Rugged 10g to 70g


Accelerometers with
Superior Zero g Bias Stability

23200C
Biaxial

Technical Data*
Features and Benefits
High Accuracy and Linearity over Wide Temperature Range
The voltage output for the 13200C and 23200C is directly proportional to the
acceleration along the axis. Each DC-coupled output is fully scaled,
referenced, and temperature compensated. Accuracy is improved by
minimizing variations due to temperature and aging effects, resulting in
sensors that are more stable over temperature than piezoelectric or
piezoresistive devices.
Calibration Certificate
Each 13200C and 23200C is supplied with a calibration certificate listing
sensitivity and offset, as well as the on-axis and transverse alignment
parameters needed to ensure rapid and efficient system implementation.
The alignment data can be used to compensate the measured values if
needed. Increased offset compensation can be obtained with Option C002,
Enhanced Temperature Calibration.
Self-Test on Digital Command
A TTL-compatible self-test input causes a simulated acceleration to be
injected into the accelerometer to verify channel integrity.
Small Size
Complete conditioned uniaxial or biaxial accelerometer in less than a cubic
inch.
uilt-In Power Supply Regulation
B
Unregulated DC power from +8.5 to +36 Volts is all that is required to measure
acceleration and temperature. Reverse power voltages of up to -80V can
be withstood indefinitely. Transients of +80V for 550ms compatible with
MIL-STD-704A can be withstood with full operation.
Easy Installation
Built-in terminal block or cable with 9-pin connector makes it easy to wire.
Two through-holes and four tapped holes simplify mounting.
uitable for Harsh Environments
S
The 13200C and 23200C are robust and can be used in harsh environments.
The units will survive 4000g powered or unpowered.
Warranty
All Summit Instruments accelerometers come with a three-year factory
warranty.

Simplify Acceleration and


Temperature Measurements
The Summit Instruments 13200C and
23200C accelerometers include a
temperature sensor in their small, rugged
package. The small size and built-in
power regulation allow the 13200C and
23200C to fit where other accelerometers
cant. Choose the bandwidth and range
options best suited for your application
to measure 10g, 15g, 20g, 25g,
30g, 35g, 40g, 50g, or 70g
accelerations on one or two axes.
The high repeatability of the builtin temperature sensor allows precise
compensation of temperature effects,
and alignment data provided on the
included calibration certificate can
be used to compensate for transverse
sensitivity and alignment errors. When
extra precision is required, Option C002,
enhanced temperature calibration is
available.
Tested over the -40 to +85C temperature
range, the accelerometers have a nominal
full scale output swing of 2 Volts. The
zero g output level is nominally +2.5
Volts. Precise values are available on the
included calibration certificate. Custom
versions of the 13200C and 23200C
can be provided for applications which
require different range and/or bandwidth.

*Data subject to change without notice


Rev. 4/17/2009

Specifications
Ta = Tmin to Tmax, 8.5 Vs 36 V, Acceleration = 0g unless otherwise noted.

Parameter

Min

Typical

Max

Units

Conditions/Notes

70

On each axis. Must specify via Option Rnnn

Range
Measurement Full Scale

10

Sensitivity
At 25C, Option R050
Drift Tmin to Tmax

38
0.5

mV/g
%

Zero g Bias Level


At 25C
Drift Tmin to Tmax, Option C001
Drift Tmin to Tmax, Option C002

2.5
60
1.5

5.5

V
mg
mg

Alignment
Deviation from Ideal Axes

1.0

3.0

degrees

Transverse Sensitivity

0.25

Nonlinearity

0.2

% FSR

Upper Cutoff Frequency -3dB Point

400

Hz

Noise Density
Option R070
Option R050, R040
Option R035, R030, R025, R020, R015, R010

3.5
3.0
3.0

mg/Hz
mg/Hz
mg/Hz

Self-Test Input Impedance

10

Temperature Sensor
Sensitivity
0C Bias Level

Outputs
Output Voltage Swing
Capacitive Drive Capability


0.05

1000

Power Supply (Vs)


Input Voltage Limits
Input Voltage - Operating
Input Current
Rejection Ratio

Precise values on cal certificate


Percent of sensitivity at 25C
Precise values on cal certificate
At 1.25C/min. temperature rate of change
At 1.25C/min. temperature rate of change

1.8
1.4
1.1

Inherent sensor error, excluding misalignment


Best fit straight line
10% Must specify via Option Bnnn

k
6.45
509

Precise values on cal certificate


Can be compensated if required

10 Hz to 400 Hz

Pullup. Logic "1"3.5V, Logic "0"1.5V


Accuracy 1C

mV/C
mV
4.95

V
pF

Iout = 0.5 mA

-80
+8.5

12

>120

+80
+36

V
V
mA
dB

-80V continuous, >36V if 550ms, duty <1%


Continuous

Temperature Range (Ta)

-40

+85

Mass

Shock Survival
Scale

DC

35

grams

-4000

+4000

Precise values on cal certificate

Any axis for 0.5ms, powered or unpowered

linearly with range option Rnnn; see Ordering Information

Mechanical

Connections
T000

Pin
Signal
Wire

T004

1
A2+
Brown

Summit Instruments, Inc.

2236 N. Cleveland-Massillon Rd.


Akron, Ohio 44333-1255

3
4
5
T+
+5VOut A1+
Orange Yellow Green

6
7
Signal- Self Test
Blue
Violet

8
+Vs
Grey

9
Gnd
White

Ordering Information
23200C

Two through holes and four 3 mm x 0.5 mm


threaded holes are provided for mounting.

2
Signal-
Red

R070

23200C
13200C
Range
R070 : 70 g
R050 : 50 g
R040 : 40 g
R035 : 35 g
R030 : 30 g
R025 : 25 g
R020 : 20 g
R015 : 15 g
R010 : 10 g

B400

T004

Bandwidth
B400 : 0 to 400 Hz
B380 : 0 to 380 Hz
B208 : 0 to 208 Hz
B142 : 0 to 142 Hz
B094 : 0 to 94 Hz
B066 : 0 to 66 Hz
B031 : 0 to 31 Hz
B6.6 : 0 to 6.6 Hz

C002
Calibration
C001 : Std room temp
calibration only
C002 : C001 cal plus -40 to +85C
enhanced offset compensation

Termination
T004 : 4 ft. cable with DB9M
T000 : Terminal Block
Tnnn : Custom length, nnn ft. (call SI)

Voice: (330) 659-3312


Fax: (330) 659-3286
www.summitinstruments.com

Vous aimerez peut-être aussi