Académique Documents
Professionnel Documents
Culture Documents
G2RS
Slim and Space-saving Power Plug-in Relay
Lockable test button models now available.
Built-in mechanical operation indicator.
Provided with nameplate.
AC type is equipped with a coil-disconnection self-diagnostic
function (LED type).
High switching power (1-pole: 10 A).
Environment-friendly (Cd, Pb free).
Wide range of Sockets also available.
LR
Electromechanical
relays
G2R
5. Terminals
S:
Plug-in
6. Classification
Blank: General-purpose
N:
LED indicator
D:
Diode
ND:
LED indicator and diode
NI:
LED indicator with test button
NDI:
LED indicator and diode with test button
7. Rated Coil Voltage
1. Relay Function
Blank: General-purpose
2. Number of Poles
1:
1 pole
2:
2 poles
3. Contact Form
Blank: SPDT
4. Contact Type
Blank: Single
Ordering Information
List of Models
Classification
Plug-in terminal
General-purpose
Enclosure
rating
Unsealed
Coil ratings
Contact form
SPDT
AC/DC
G2R-1-S
DPDT
G2R-2-S
LED indicator
G2R-1-SN
G2R-2-SN
G2R-1-SNI
G2R-2-SNI
Diode
G2R-1-SD
G2R-2-SD
DC
G2R-1-SND
G2R-2-SND
G2R-1-SNDI
G2R-2-SNDI
Note: When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
New model
Example: G2R-1-S 12 VDC (S)
Rated coil voltage
General-purpose Relay
G2RS
G-5
DIN-rail/surface-mounting Socket
Screwless clamp terminal
Back-mounting Socket
Screw terminal
Terminals
Model
1 pole
P2RF-05S (See note.)
+
G2R-1-S(N)(D)(ND)(NI)(NDI)
(P2CM-S (option))
P2RF-05-E
PCB terminals
P2R-05P, P2R-057P
P2RF-05
Solder terminals
P2R-05A
2 poles
P2RF-08S (See note.)
+
G2R-2-S(N)(D)(ND)(NI)(NDI)
(P2CM-S (option))
P2RF-08-E
PCB terminals
P2R-08P, P2R-087P
P2RF-08
Solder terminals
P2R-08A
Note: Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.
Model
P2CM-S
Nameplate
Socket Bridge
Mounting DIN-rails
Applicable Socket
Description
DIN-rail-connecting Socket
Back-connecting Socket
Model
Mounting DIN-rail
End plate
PFP-M
Spacer
PFP-S
Mounting plate
P2R-P*
*Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Specifications
Coil Ratings
Rated voltage
Rated current*
50 Hz
AC
Coil
resistance*
60 Hz
24 V
43.5 mA
37.4 mA
253
0.81
1.55
110 V
9.5 mA
8.2 mA
5,566
13.33
26.83
120 V
8.6 mA
7.5 mA
7,286
16.13
32.46
230 V
4.4 mA
3.8 mA
27,172
72.68
143.90
240 V
3.7 mA
3.2 mA
30,360
90.58
182.34
Rated voltage
Rated current*
Coil
resistance*
DC
Armature
ON
Armature
ON
6V
87.0 mA
69
0.25
0.48
12 V
43.2 mA
278
0.98
2.35
24 V
21.6 mA
1,113
3.60
8.25
48 V
11.4 mA
4,220
15.2
29.82
Must
operate
voltage
Must
release
voltage
Power
consumption
(approx.)
% of rated voltage
80% max.
30% max.
Must
operate
voltage
Must
release
voltage
110%
Max.
voltage
0.9 VA at 60 Hz
Power
consumption
(approx.)
% of rated voltage
70% max.
15% min.
* The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of 10%.
G-6
Max.
voltage
110%
0.53 W
Contact Ratings
Number of poles
1 pole
Load
Resistive load
(cos = 1)
Inductive load
(cos = 0.4; L/R = 7 ms)
Resistive load
(cos = 1)
2 poles
Inductive load
(cos = 0.4; L/R = 7 ms)
Rated load
10 A at 250 VAC;
10 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
10 A
5A
10 A
2,500 VA,
300 W
100 mA at 5 VDC
5A
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
10 mA at 5 VDC
Characteristics
Item
1 pole
Contact resistance
100 m max.
15 ms max.
Max. operating
frequency
Mechanical:
Electrical:
2 poles
18,000 operations/hr
1,800 operations/hr (under rated load)
Vibration resistance
Destruction:
Malfunction:
Shock resistance
Destruction:
Malfunction:
1,000 m/s2
200 m/s2 when energized; 100 m/s2 when not energized
Endurance
Mechanical:
Electrical:
Ambient temperature
Operating:
Ambient humidity
Operating:
5% to 85%
Weight
Approx. 21 g
Electromechanical
relays
Insulation resistance
Dielectric strength
Approved Standards
UL 508 (File No. E41643)
Model
Contact
form
G2R-1-S SPDT
Coil ratings
5 to 110 VDC
5 to 240 VAC
G2R-2-S DPDT
IEC/VDE (EN61810)
Contact ratings
Operations
Contact
form
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
1 pole
100 x 103
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
2 poles
100 x 103
Contact
form
G2R-1-S SPDT
G2R-2-S DPDT
Coil ratings
5 to 110 VDC
5 to 240 VAC
Coil ratings
Contact ratings
Operations
LR
Number of
poles
Contact ratings
Operations
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
Coil ratings
Contact ratings
Operations
1 pole
5 to 110 VDC
5 to 240 VDC
100 x 103
2 poles
5 to 110 VDC
5 to 240 VDC
100 x 103
General-purpose Relay
G2RS
G-7
Engineering Data
Maximum Switching Power
Plug-in Relays
G2R-2-S
G2R-1-S
100
AC inductive load
(cos = 0.4)
AC resistive
load
10
DC resistive
load
DC inductive load
(L/R = 7 ms)
0.1
10
100
100
AC resistive
load
DC resistive
load
0.1
1000
AC inductive load
(cos = 0.4)
10
DC inductive load
(L/R = 7 ms)
10
100
1000
Endurance
Plug-in Relays
G2R-2-S
10,000
5,000
1,000
250-VAC/30-VDC
resistive load
500
100
50
G2R-1-S
5,000
1,000
500
100
250-VAC
50 inductive load
(cos = 0.4)
DC coil
AC coil
G-8
DIN-railing Resistance
Base 250
Environmental Protection
RT 1
Flammability Class
Pollution degree
Creepage Distance
8 mm
Clearance Distance
8 mm
Contact Material
AgSnIn
UL 94V-0
UL 94V-2
For lock
operation
Electromechanical
relays
Relay in
normal operation
1 pole model
2 pole model
6 / 8 ms
6 / 10 ms
12 / 4 ms
11 / 15 ms
1
10
0.8
0.6
0.4
G2R-2-S
2 contacts
in series
1
0.8
0.6
0.4
G2R-1S
0.2
Cos(p.f.)
0.1
20
40
60
80
100
120
140
160
180
200
220
General-purpose Relay
G2RS
G-9
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G2R-1-S
29 max.
13 max.
20
35.5 max.
4.75
7.5
0.5
1
DC
24V
5.2
17.5
DPDT Relays
G2R-2-S, G2R-2-SN, G2R-2-SNI
G2R-2-SD, G2R-2-SND, G2R-2-SNDI
13 max.
2.5
7.4
G-10
35.5 max.
5
19.4
8.9
2.4
6.2
20
29 max.
0.5
G2R-2-SD (DC)
P2RF-05-S
Terminal Arrangement
(Top View)
36.5 max.
11
32.6
14
27.6
12
92.0 max.
Standard model
35.4
24.5
22.6
(5.3)
28.5
18.0 max.
A1 A2
32.6
Terminal Arrangement
(Top View)
38.2 max.
P2RF-08-S
36.5 max.
21 11
27.6
Electromechanical
relays
24 14
32.6
22 12
(3.4)
Standard model
35.4
92.0 max.
24.5
22.6
A1 A2
(5.3)
28.6
18.0 max.
32.6
Insulating coating
L
1.2 dia. conductor (See note 1.)
14
16.8
40.35
36
General-purpose Relay
G2RS
G-11
Terminal Arrangement
(Top View)
P2RF-05-E
Five, M3.57
48 max.
(14)
39.5
35.5
85.5 max.
Mounting Holes
(for Surface Mounting)
3.2-dia.
hole
(11)
2
(12)
39.50.1
3.5-dia.
hole
M3 or
3.5-dia.
hole
(A1)
(A2)
11.5
61 max.
16.0 max.
P2RF-08-E
2
Terminal Arrangement
(Top View)
1.5
Eight, M38
48.0 max.
Mounting Holes
(for Surface Mounting)
39.5
(21)
(22)
(24)
7
5
2
4
(11)
(12)
(14)
3.2-dia.
hole
35.5
85.5
max.
39.50.1
3.5-dia. hole
(A1)
(A2)
5
61.0
max.
M3 or
3.5-dia.
hole
11.5
16.0 max.
P2RF-05
Terminal Arrangement
(Top View)
Five, M3.5 x 8
4-dia. holes
Mounting Holes
(for Surface Mounting)
4.2-dia. hole
35.5
71.5 max.
300.05
19.5
30 max.
19.5 max.
M3 or 3.2-dia.
hole
54 max.
P2RF-08
2
7
Eight, M3.5 x 8
4-dia. holes
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
4.2-dia. hole
35.5
71.5 max.
300.05
19.5
30 max.
19.5 max.
54 max.
G-12
M3 or 3.2-dia.
hole
P2RF-@
62.0
66.5
70.5
67.0
P2RF-@-S
72.0
65.0
28.6
(5.30)
P2R-05P (1-pole)
4
Terminal Arrangement
(Bottom View)
14.5 max.
Electromechanical
relays
Back-connecting Sockets
Mounting Holes
Tolerance: 0.1
4
6
4.5
35.5 max.
15
Five,
1.6-dia.
holes
4.5
1.2
4
15
3.5
4
1.5
(5)
4
7
36.5 max.
P2R-08P (2-pole)
4
0.3
14.5 max.
Mounting Holes
Terminal Arrangement
(Bottom View)
7.5
5
5
5
35.5 max.
20
1
5
20
2.8
1.5
(4.3)
7.5
Terminal plate thickness: 0.3
36.5 max.
General-purpose Relay
G2RS
G-13
P2R-05A (1-pole)
14.5 max.
1.2
0.3
Terminal Arrangement
(Bottom View)
6.7
3.8
35.5 max.
16.7
Panel Cutout
Five, 3 x 1.8-dia. holes
13.60.1
6
36.5 max.
P2R-08A (2-pole)
30.50.2
14.5 max.
1.2
0.3
5
5
35.5 max.
Recommended thickness of
the panel is 1.6 to 2.0 mm
20
2.6
2.8
1.5
Eight, 3 x 1.2-dia. holes
7.5
Terminal plate thickness: 0.3
P2R-057P
14 max.
8.7
0.7
16.4
10.4
36.5 max.
Terminal Arrangement
(Bottom View)
Mounting Holes
Five,
1.6-dia.
holes
40.1
60.1
37 max.29.6
4.50.1 150.1
8.7
40.1
5
7.4
70.1
41 max.
P2R-087P
14 max.
7.5
Terminal Arrangement
(Bottom View)
16.4
1
10.4
Mounting Holes
7.5
37 max. 29.1
Eight,
1.3-dia.
holes
5
5
20
7.4
8.9
(8.1)
41 max.
G2R-@A
G2R Relay
44.5
G-14
G2R Relay
38.0
P2R-_P
Socket
G2R-@7P
P2R-_A
Socket
47.5
Mounting DIN-rails
PFP-100N, PFP-50N
PFP-100N2
16
7.30.15
4.5
4.5
15
25
25
25
25
10
10
1,000 (500)
350.3 27
270.15
350.3
15 (5)
15
25
25 15
25
25
10
10
24
29.2
1.5
1,000
End Plate
Spacer
10
6.2
PFP-M
PFP-S
16
12
1.8
1
1.8
11.5
10
M4 x 8 pan
head screw
35.5 35.3
34.8
44.3
1.3
4.8
16.5
Electromechanical
relays
50
Precautions
!Caution
Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
!Caution
Check that the test button is released before turning ON relay circuits.
!Caution
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.
!Caution
Use an insulated tool when you operate the test button.
General-purpose Relay
G2RS
G-15
G-16
In the interest of product improvement, specifications are subject to change without notice.