Vous êtes sur la page 1sur 3

PVSYST V6.

25

23/12/14 Page 1/3

Grid-Connected System: Simulation parameters


Project :

Dhekidal_10MW_Project

Geographical Site

A_Balipara_SGP50

Situation
Time defined as

Latitude
Legal Time
Albedo
A_Balipara_SGP50

Meteo data:

Country
26.8N
Time zone UT+7
0.20
Synthetic - SolarGIS

Longitude
Altitude

India
92.7E
84 m

L
A
I
R
T
t
s
y
s
V
P

Simulation variant :

10MW_Balipara-Project

Simulation date

23/12/14 21h36

Simulation parameters

Tilt

Collector Plane Orientation


10 Sheds
Inactive band
Shading limit angle
Models used
Horizon
Near Shadings

Pitch
Top
Gamma

Transposition

25

10.0 m
0.00 m
14.85
Perez

Azimuth

Collector width
Bottom
Occupation Ratio

Diffuse

4.00 m
0.00 m
40.0 %
Erbs, Meteonorm

Free Horizon

Mutual shadings of sheds

PV Array Characteristics
PV module

Si-poly

Model
Manufacturer
In series
Nb. modules
Nominal (STC)
U mpp
Module area

TSM-255 P05A 2014_03


Trina Solar
24 modules
In parallel
39360
Unit Nom. Power
At operating cond.
10037 kWp
656 V
I mpp
64424 m

Model
Manufacturer
Operating Voltage
Nb. of inverters

PVS800-57-1000kW-C_1
ABB
570-850 V
Unit Nom. Power
10 units
Total Power

Number of PV modules
Total number of PV modules
Array global power
Array operating characteristics (50C)
Total area
Inverter
Characteristics
Inverter pack

1640 strings
255 Wp
8998 kWp (50C)
13713 A

1000 kW AC
10000 kW AC

PV Array loss factors


Array Soiling Losses
Thermal Loss factor
Wiring Ohmic Loss
LID - Light Induced Degradation
Module Quality Loss
Module Mismatch Losses
Incidence effect, ASHRAE parametrization
User's needs :

PVsyst Evaluation mode

Uc (const)

29.0 W/mK

Loss Fraction
Uv (wind)

1.5 %
0.0 W/mK / m/s

Global array res.

0.54 mOhm

Loss Fraction

1.0 % at STC

1 - bo (1/cos i - 1)

Loss Fraction
Loss Fraction
Loss Fraction
bo Param.

1.0 %
-0.8 %
0.8 % at MPP
0.04

IAM =

Unlimited load (grid)

PVSYST V6.25

23/12/14 Page 2/3

Grid-Connected System: Main results


Project :

Dhekidal_10MW_Project

Simulation variant :

10MW_Balipara-Project
System type
Sheds disposition, tilt
Model
Nb. of modules
Model
Nb. of units
Unlimited load (grid)

Main system parameters


PV Field Orientation
PV modules
PV Array
Inverter
Inverter pack
User's needs

Grid-Connected
25
azimuth
TSM-255 P05A 2014_03
Pnom
39360
Pnom total
PVS800-57-1000kW-C_1
Pnom
10.0
Pnom total

L
A
I
R
T
t
s
y
s
V
P

Main simulation results


System Production

Produced Energy
Performance Ratio PR

Specific prod.

13974 MWh/year
85.0 %

Normalized productions (per installed kWp): Nominal power 10037 kWp


6

1392 kWh/kWp/year

Performance Ratio PR

1.0

PR : Performance Ratio (Yf / Yr) : 0.850

Lc : Collection Loss (PV-array losses)


0.6 kWh/kWp/day
Ls : System Loss (inverter, ...)
0.08 kWh/kWp/day
Yf : Produced useful energy (inverter output) 3.81 kWh/kWp/day
5

0
255 Wp
10037 kWp
1000 kW ac
10000 kW ac

Performance Ratio PR

Normalized Energy [kWh/kWp/day]

0.8

0.6

0.4

0.2
1

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

0.0

Dec

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

10MW_Balipara-Project
Balances and main results
GlobHor

T Amb

GlobInc

GlobEff

EArray

E_Grid

EffArrR

kWh/m

kWh/m

kWh/m

MWh

MWh

January

104.0

14.80

133.0

125.7

1198

1176

13.99

13.72

February

111.0

16.80

130.4

122.9

1160

1138

13.81

13.55

March

132.0

21.00

141.1

132.4

1227

1203

13.50

13.23

April

131.0

23.80

130.2

121.7

1116

1094

13.30

13.04

May

149.0

25.70

140.3

130.9

1201

1178

13.28

13.03

June

130.0

26.90

119.6

111.1

1022

1000

13.27

12.99

July

132.0

27.10

122.5

114.0

1043

1021

13.22

12.94

August

134.0

27.10

130.7

122.1

1112

1090

13.21

12.95

September

129.0

25.60

135.6

127.4

1159

1137

13.26

13.01

October

134.0

22.70

156.7

148.2

1356

1331

13.43

13.19

November

116.0

19.00

150.2

142.4

1329

1304

13.74

13.48

December

109.0

15.80

147.6

139.9

1326

1302

13.95

13.70

Year

1511.0

22.22

1637.7

1538.7

14249

13974

13.50

13.24

Legends:

PVsyst Evaluation mode

GlobHor

Horizontal global irradiation

EArray

T Amb

Ambient Temperature

E_Grid

Energy injected into grid

GlobInc

Global incident in coll. plane

EffArrR

Effic. Eout array / rough area

GlobEff

Effective Global, corr. for IAM and shadings

EffSysR

Effic. Eout system / rough area

EffSysR

Effective energy at the output of the array

Sep

Oct

Nov

Dec

PVSYST V6.25

23/12/14 Page 3/3

Grid-Connected System: Loss diagram


Project :

Dhekidal_10MW_Project

Simulation variant :

10MW_Balipara-Project

Main system parameters


PV Field Orientation
PV modules
PV Array
Inverter
Inverter pack
User's needs

System type
Sheds disposition, tilt
Model
Nb. of modules
Model
Nb. of units
Unlimited load (grid)

Grid-Connected
25
azimuth
TSM-255 P05A 2014_03
Pnom
39360
Pnom total
PVS800-57-1000kW-C_1
Pnom
10.0
Pnom total

L
A
I
R
T
t
s
y
s
V
P

0
255 Wp
10037 kWp
1000 kW ac
10000 kW ac

Loss diagram over the whole year

1511 kWh/m

+8.4%

Horizontal global irradiation


Global incident in coll. plane

-2.2%

Near Shadings: irradiance loss

-2.4%

-1.5%

1539 kWh/m * 64424 m coll.

Soiling loss factor

Effective irradiance on collectors

efficiency at STC = 15.60%

PV conversion

15463335 kWh
-0.2%

Array nominal energy (at STC effic.)


PV loss due to irradiance level

-6.2%

PV loss due to temperature

+0.8%

Module quality loss

-1.0%

LID - Light induced degradation

-0.8%

Module array mismatch loss

-0.6%

Ohmic wiring loss


Array virtual energy at MPP

-1.9%

Inverter Loss during operation (efficiency)

14249013 kWh

0.0%
0.0%
0.0%
0.0%

PVsyst Evaluation mode

IAM factor on global

13973743 kWh

Inverter Loss over nominal inv. power


Inverter Loss due to power threshold
Inverter Loss over nominal inv. voltage
Inverter Loss due to voltage threshold
Available Energy at Inverter Output

13973743 kWh

Energy injected into grid