AutoCAD DRAWING STANDARDS 15 may 2008 Approved Issue 1 Rob Jobber CAD Team Supervisor Estates and Facilities Building 35 University of Southampton Highfield Southampton SO17 1B) Telephone —_ +44 (0)23 8059 4036 Fax +44 (0)23 8059 3840 E-mail raj@soton.ac.uk www.estates.soton.ac.uk Southampton CONTENTS Lo 20 30 40 5.0 60 10 80 Introduction Page 3 Definitions Page 3 Drawing Production Page 4-6 Room Numbering Page 6 Drawing Frames Page 6-7 Standard Layering Page 7-15 File Submission Page 16 Standard M&E Symbols Page 16-40 Power Electrical Distribution Fire Alarm Fire Safety Fire Fighting Lighting Data and Telecom Security com Mechanical ~ Ductwork Pipework 1.0 INTRODUCTION AutoCAD is now widely used by Estates and Facilities for the production and amendment of its drawings. It is now necessary to issue drawing standards co ensure conformity and understanding of drawings. This procedure lays out the requirements for producing standard CAD drawings, based on BS1192, that must be followed by all Estates and Facilities CAD users, Architects, Consultants or Contractors working on University projects and the drawings stored on the drawing database. 2.0 DEFINITIONS: 2.1 Current Building Floor Plans Current Building floor plans are the most recent set of CAD drawings available for each University building. They typically show walls, partitions, door and window structural openings, room areas and numbers etc. ‘These drawings are available on the Estates and Facilities J/Drive or can be provided by e-mail or on CD by the CAD Team if required, 2.2 External Reference ‘An external reference (Ref) is a drawing which is Imported and attached onto a host drawing. The Individual clements of this drawing cannot be altered within the host drawing: however layers applying to the XRef may be turned onloff as required, XRefs must be attached on to an appropriate layer name. Future alterations to an XRef will alter any other drawings that have the same XRef attached. 3.0 DRAWING PRODUCTION 3.1 Drawing Unies All drawings shall be drawn in Model Space at a scale of I:1 where one drawing unit = Imm. Angles shall be shown in decimal degrees and measured anti-clockwise with 0 measured as a horizontal ine drawn to the right. The preferred scales for use are: 1:1, 1:10, 1:20, 1:50, 1:100, 1:200, 1:250, 1:500 and 1:1250. 3.3 Drawing Revisions Drawing revisions shall be given an alphabetic issue letter which appears in the title box. Revisions to drawings shall be clouded to clearly outline the changes, and this shall be placed on its own layer. Revisions shall be described in sufficient detail to enable the nature of the revision to be identified and shall be located clearly in a revision box above the drawing ttle block. 3.3 Text styles Gill Sans and Palatino are the standard fonts of the University of Southampton visual identity guidelines and should be used for text on all drawings and documents. All drawings are to have a standard text height of 25mm, 3.5mm, 5.0mm and 7.0mm and a width no greater than I at a scale of I:I. For example a drawing drawn at [:100 would have a text height (in Model Space) of 250mm, and the height of the text in Paper Space would be 2.5mm. Text no smaller than 1.8mm should be used. 34 Text Height Table ‘Text Heights (mm) Drawing Scale (1: ) 28 35 5 7 1 (35 5 7 Saas 125 [zs 3B 35 10 a 35 50 70 20 70 100 140 50 175 [250 350 100 350° 500 700 200 7 700 1000 1400 250 [as 1250 1750 500 1750 2500 3500 1250 ‘B75 6250 8750 3.5 Dimensions Leaders (arrows) and dimensions must have solid arrow heads. Text/dimensions must be centred above the dimension line. Dimensions and Leaders to be located on corresponding layer and are to be scaled relative to the scale of the drawing. 3.6 Pen Settings Estates and Facilities Standard Pen Sottings (Estates and Faclities.ctb) ‘Colour No Pen Thickness Colour Plotted Colour on Screen 9 | 0.075 Grey 1 0.18 3 Red 6 sana | Come 3 Magenta 7 025 e WhierBlack 8 025 oa Dark Grey 2 03 3 Yellow 3 035 é Green 4 05 3 yan 5 07 A Bue 200 0.075 Purple 120 on Aqua 202 03 Dark Purple a 0.18 Dark Green| 720 0.18 Pink zl 025 Orange 140 025 - % Blue 250 025 a Dark Grey 252 025 = 30 035 g | Orange 50 oa 4 = “4 05 3 Brown 78 05 z Dark Green ma 1 2 Pink 40 025 Orange ‘Orange 8% 025 Dark Green Dark Green 180 025) Purple Purple 201 0.25 Mauve Mauve 221 0.25 Pink Pink 253 025 Grey Grey 10 o7 Red Red 34 o7 Brown Brown 80 07 Green Green Bo o7 Blue Blue If the recommended pen thicknesses and colours can not be used a .ctb plot style file must be supplied with the drawing files. ‘The use of the colour, pen thicknesses and line types is at the discretion of the drawing author but all must be drawn By Layer. 3,7 Line types Standard AutoCAD line types must be used, Site survey drawings showing main service supply routes may use custom line types such as: These custom line types must be supplied as a legend on the relevant drawings. 3.8 Areas (On any projects where a new space is created or an existing space is amended the GIFA and NETT areas in 'm, room numbers and room/space usage are to be shown. The GIFA and NETT areas are to be identified by polylines on the drawing and are to be stored on separate layers. GIFA Gross Internal Floor Area is the total area of buildings owned or occupied or maintained by the institution measured to the internal face of the perimeter walls at each floor level (ie the footprint of the building ‘excluding the width of the outside walls). It includes areas occupied by internal areas and partitions. Net Net Internal Area is the usable area within a building measured to the internal face of the perimeter walls at each floor level. NIA covers all areas which are used for a specific purpose. It does not include those parts of buildings which enable them to function. Balance areas include corridors and other circulation areas, internal ‘open-sided balconies, stairways, stairwells (and voids over), entrance lobbies, foyers, atria, lifts, lavatories and toilets, cloakrooms, cleaners’ stores, cleaners’ cupboards, plant rooms, tank rooms, fuel stores, loading bays, duets, boiler houses, permanent and continuous air conditioning and heating or cooling apparatus. 4.0 ROOM NUMBERING Guidelines for Numbering & Signing a Building 4.1 Allocation All room numbering is managed by the Estates and Facilities Space Management team. Requests for new or revised room numbering should be made to the Space management team via Janet Middleton, ihm |@soronac.uk. 5.0 DRAWING FRAME SETUP 5.1 Title Blocks Al drawings shall be drawn within the bounds of a Tide block. Estates and Facilities drawing title blocks are available electronically by e-mail or on CD. All drawing frames are to be scaled at 1:1 and must comprise of an outline frame, title block with all project information completed, a revision block and an approved University cof Southampton logo which can be found at the following link: hetpid/www.resource Lsoton.ac.uk/cams/marcomms/university_branding/brand_guidelines.hem| UNIVERSITY OF Southampton Title blocks shall be inserted into a drawing in Paper Space at an origin of 0,0. All title blocks will be in an attribute format with editing facility. Example of a typical Estates and Facilities Title Block: The following layer coding is listed as an example of typical layers used by the Estates and Facilities Department, All coding and layer definitions must be based on BS 1192 Guidelines. Any drawings created by Consultants or Contractors must include a list of layers used, their reference numbers and content. GROUND SUBSTRUCTURE. ‘A100 GROUND, SUBSTRUCTURE ~ (General) A-110 GROUNDWORK ~ (General) AcII| Ground relief ~ embankments, cutting, slopes A113. Ground composition — stabilised ground A114 Groundwater ALLIS. Underground — underpinning, tunnels, culverts, land drainage ALI Parts, accessories ~ excavations, trenches, cut and fill A-160 FOUNDATIONS ~ (General) A162 Retaining walls A163 Water retaining walls -caissons ‘A-164 Foundations — pad, foot, strip ‘A-169. Parts, accessories ~ damp proofing, reinforcement, insulation A-I70_ PILE FOUNDATIONS ~ (General) AITL Sheet piling ‘A-I72_ In-situ formed foundations ~ bored, cased, uncased A173. Pre-formed foundations ~ driven, jacked, screwed AcI79 Parts, accessories - reinforcement. STRUCTURE, PRIMARY ELEMENTS. CARCASS. ‘A-200 STRUCTURE, PRIMARY ELEMENTS, CARCASS ~ (General) A210 EXTERNAL WALLS ~ (General) A211 Complete walls ~ cavity and inner walls A212 Outer leaf of external walls ‘A-213 Inner leaf of external wals A214 Curtain walls A216. External framing and cladding A218 Other walls ~ parapet gable A219 Reinforcement, Tes, insulation, Damp Proofing A220 INTERNAL WALLS, PARTITIONS ~ (General) A-221 Complete internal walls A-223 Partitions ~ fixed or demountable ADS Service poles A-226 Internal framing or cladding A228 Other walls ~ party walls A229 Parts, accessories ~ reinforcement, ties, insulation A230 FLOORS ~ (General) 4-232. Slab floors, monolithic floors ‘A234 Composite, assembled floors A237 Balconies, galleries A238 Other floors ~ metal decks, metal plates ‘A240 STAIRS ~ (General) A241 Ramps A242 Seraighe A243 Dog-leg A244 Curved and spiral A245. Escape stairs, open-well stairs A246 Ladders A270 ROOFS - (General) A2TL Flat Roofs A272. Pitched roofs A275 Other roofs ~ domes, steeples, spires A276 Space-frame rools AQT Canopies A279. Parts, accessories — decking, trusses, insulation ‘A-280 BUILDING FRAMES ~ (General) A281 Metal columns ‘A282 Concrete columns ‘A283 Metal beams ‘A-284 Concrete beams A-285 Timber frames ‘A-286 Space ~ frames as building frames A287 Other frames ~ shafts, ducts, chimneys ‘4-289 Parts, accessories ~ reinforcement, connections SECONDARY ELEMENTS, COMPLETION OF STRUCTURE A-300 SECONDARY ELEMENTS, COMPLETION OF STRUCTURE ~ General A310 EXTERNAL WALL COMPLETIONS (Windows/Glasswork) ~ (General) A-313. Composite window/door openings A314 External windows A315 External Doors A316 Revolving Doors ABI7_ External hatches, meter-box doors A318 Ocher wall completions — louvred, barred A319. Parts, accessories — intel, sils,ironmongery ‘A320 INTERNAL WALL COMPLETIONS (Doors) ~ (General) 4-323 Composite window/door openings A-324 Internal windows ‘A-325 Internal doors ‘A327 Internal hatches ‘A329. Parts, accessories ~ internal lintels, arches 4-330 FLOOR COMPLETIONS, SECONDARY ELEMENTS ~ (General) A331 Access floors, cavity floors A333 Roused floor-grid, metal docks A335. Floor doorslopenings, rap doors ‘A-340 STAIR BALUSTRADES, HANDRAILS ~ (General) ‘A-350._ CEILINGS ~ (General) A-351 Suspended ceilings, tiles, panelled ‘A-352 Suspended ceilings, louvered A-359 Parts, accessories ~ insulation, access hatches A370 ROOF COMPLETION ~ (General) A371 Roof - lights A.373 Composite window/door openings to roofs A374 Roof windows A-376 Roof balustrades, parapets A378 Roof Walleways FINISHES TO THE STRUCTURE ‘A-400 FINISHES TO THE STRUCTURE ~ (General) ‘A410 EXTERNAL WALL FINISHES — (General) AcALL Sandwich cladding with externalfinternal lining A412 Wall cladding panels A413. Weather-boarding, shiplap cladding AA14 Wall cladding tiles AAS. Coating to external walls, render A419 Parts, accessories ~ external insulation ‘A420 INTERNAL WALL FINISHES ~ (General) AALL Drylning ‘422 Plascered internal walls AI3_Timber finishes AVA Internal wall tiles AIS Coating to internal walls - paint ‘A426 Wallcovering ~ paper, vinyl -A29 Parts, accessories ~ insulation, trim ‘A430 FLOOR FINISHES ~ (General) ‘8-431 _Jointess floor finishes ~ cement, resin ‘A432 Rigid tile and slab flooring ~ ceramic, stone ‘A-433_ Flexible tle and sheet flooring - plastics 434 Seip flooring - timber ‘ABS Carpets, carpet tiles 436 Floor screeds ‘A439 Parts, accessories ~ adhesives, skrtings, trim ‘A470 ROOF FINISHES (Outlines) ~ (General) 10 AAT A472 AAT A474 ATS A479 Roofing membranes Mastic asphalt roofing Roof tiles, slates Sheet roof cladding Roof screeds Parts, accessories ~ trims, vents, sealants SERVICES P.500 P.520 P52 522 523, 524 525, 526 527 528, P529 530 P.531 533 P53 535 537 P.539 M540 M541 M542 M543, M544 M546 M549 M550 M551 M552 M555 M556 M-560 M561 M562 M563 M568 M569 M570 M571 M573 M574 M.S75 M576 M579 M580 M.590 SERVICES ~ (General) WASTE DISPOSAL, DRAINAGE ~ (General) Refuse disposal Gaseous wastes Foul drainage, sewage disposal ‘Chemical, petrol waste Rainwater, surface water drainage Incernal (above ground) drainage Below ground drainage Drainage castings ~ covers, frames, gullies Parts, accessories ~ traps, vents, manholes WATER AND LIQUID SUPPLY ~ (General) Cold water supply Hot water supply Hot water from individual appliances Special water supply ~ softened, de-ionised Petrol, cil supply Parts, accessories — cistern, taps, valves, lagging GAS SUPPLY ~ (General) Fuel gas supply Steam supply ‘Compressed air supply - industrial ‘Vacuum Supply Special gases Parts, accessories - meters SPACE COOLING, REFRIGERATION - (General) Central refrigeration cooling water/space cooling cold rooms Environment cooling Refrigeration fixed equipment ~ mortuary blood banks Equipment cooling (grille, ancillary equipment) SPACE HEATING ~ (General) By energy source ~ oil, gas, electricity, solid, solar District, communal heating Central heating Heating from local appliances Parts, accessories — lagging, storage, distribution VENTILATION ~ General) Ceneral airconditioning Air conditioning by local appliances ‘Air-transfer gilles{dampers, wall-mounted ~ and hospitals Mechanical ventilation, central ventilation Ventilation by local appliances ~ extract fans Smoke ventlation PUBLIC HEALTH AND RAW WATER ~ (General) PART ACCESSORIES TO PIPED, DUCTED SERVICES ~ FLUES/ LININGS & BOILERS ~ (General) W M591 Domestic heating services — pipework M-595._ Environment heating services - pipework M598 Boiler Flues SERVICES, MAINLY ELECTRICAL E600 E610 E6II E612 £613, E614 E615 E616 E617 E618 £619 £620 E621 £622 £623, £629 £630 £631 £632 £633 £636 £638 £639 v-640 V-64l V-642 V643 v.644 V-645 V-648 v.649 v-650 v.65! v-652 Vv653 V-654 V-657 V-658 v-659 A660 A661 A663 A664 A665 A666 A667 A668 A669 ‘SERVICES, MAINLY ELECTRICAL ~ (General) ELECTRICAL SUPPLY ~ (General) Mains ineake to local control gear High-voleage supply and distribution cabling High-voltage switchgear and power system plant Electrical management system Low-voltage main power distribution Public mains electrical supply Emergency, standby supply Low-voltage switchgear and power system plant Parts, accessories ~ distribution boards, switchgear, meters POWER SUPPLY ~ (General) Trucking, conduit Wiring cable, wiring systems Electrical accessories ~ sockets, plugs, meters Parts, accessories — controls, outlets LIGHTING - (General) General lighting systems Local lighting, spotlight, display lights Operational lighting Floodlighting Emergency lighting Parts, accessories ~ lamps COMMUNICATIONS ~ (General) Audio visual - television, video, closed-circuit television ‘Audio ~ radio, telephone, intercom ‘Communications ~ patient/staff call nd service alarm systems (excluding fire systems) Signal communications ~ telex fax Clocks, central time source Frames - voices Parts, accessories — loudspeakers, exchanges, television points. ‘TELECOMMUNICATIONS ~ (General) Cable trays ~ trucking, conduit, ceiling and floor voids, risers ‘Communications cabling ~ data, voice Non-cabled equipment cabinets Data terminals PCs, terminal equipment, workstations Host equipment Frames ~ data, general Other devices ~ multiplexers, MSAUs, modems ‘TRANSPORT ~ (General) Lifts Cleaning cradles Escalators Conveyors Moving pavements Cranes, hoises Mechanical - pallets Parts, accessories ~ pulleys, motors, controls 12 F.670 F671 F674 F676 F678 F679 $-680 5-681 5-682 5-683 $-686 $-688 5-689 £690 £691 E694 £696 £698 FIRE SYSTEMS — (General) Fire alarm, voice alarm system Fire alarm smoke detection system Sprinkler system Fire extinguishers, hose-reels, cabinets Hazardous and poisonous substances ‘SECURITY PROTECTION ~ (General) Combined security/fire protection Security services, burglar protection, access control equipment. Fire fighting Bird/vermin nuisance Sound control Parts, accessories — buzzers, bells, alarms EARTHING ~ (General) Safety earth Lighting protection Funetional earth RF grid EITTINGS AND FURNITURE 2-700 Z70 Z7I1 Z7I2 Z713 Z7l4 Z718 2-730 Z2I Z-732 ZTA Z735 Z-736 Z738 A740 ATL ATA AT ATM ATS AAT A748 Z-150 ZI5\ Z153 Z155 Z158 Z159 Z-160 Z-161 Z162 2-163 L164 FITTINGS AND FURNITURE ~ (General) CIRCULATION FITTINGS - (General) Signs, lettering, notice-boards Display fittings, plant displays Entrance mats, frames Emergency signs Reception fittings KITCHENS, CULINARY FITTINGS ~ (General) Kitchen units, worktops Kitchen sinks, disposable units, draining boards Cooking appliances ~ cookers, fryers, grils, ovens Culinary storage appliances ~ fridges, freezers Bar fitings Vending machines, drinking fountains, water coolers SANITARY FITTINGS ~ (General) Sanitary suites ‘Washing ftcings ~ baths, bidets, showers, basins Drying ftings ~ rowel — ral, driers Water closets, urinals Incinerators, macerators Sanitary supply ~ soap dispensers, sanitary towel dispensers Other sanitary feings - mirrors CLEANING FITTINGS ~ (General) Washing machines Drying machines Sterilising equipment Dry cleaning machines Dishwasher ‘STORAGE FITTINGS ~ (General) Composite storage fittings ~ storage walls Cupboards Drawers Shelving, racking 13, L165 Z166 Z167 2768 2169 2-780 2783 Z-786 Z787 2.788 7-789 Suspended storage (Other storage — safes, lockers Screening ~ screen, blinds, curtains, tracks demountable screens Hooks, pegs, brackets, Electronic media LOOSE FITTINGS ~ (General) Sofe furnishings, upholstery Works of art, sculpture, murals Plants Boards Conference equipment EXTERNAL WORKS 7.300 2901 7902 7903 2.904 2907 Z910 Zit Z912 Z913 Z917 Z918 7.920 Z9u1 Z92 2923 Z925 7926 Z97 7.930 Z931 7.932 7.933 7.934 2.935 2937 7.939 7.940 Z9AL Z942 2943 Z.944 Z.945 7.946 Z.947 7.948 7.949 7.950 2.951 7.952 2.953 EXTERNAL WORKS — (General) North point, scales, ttle blocks Matchlines Notes Hatch patterns Section drawings SITE INFORMATION ~ General) Boundary lines, survey benchmarks Bearing and distance labels Easements, rights-of-way, setbacks Existing buildings Proposed buildings SURVEY INFORMATION ~ (General) Existing contours Proposed contours Spot elevations, heights Cut and fill Daylight and sunlight lines Notes and calculations LAND DRAINAGE ~ (General) Sprinklers Layout coverage Secondary pipes Mainline pipes Pipe sizes Other equipment Schedules LANDSCAPING - (General) Existing Trees (denote if TPO exists) Proposed trees Trees to be removed Shrubs Ground cover Grass and lawns Boulders Rock, bark and other landscaping beds Schedules ROADS, PAVING, CAR PARKING ~ (General) Road centre-lines Kerbs Traffic islands Z955 2.956 2957 2.958 7.959 7.960 Z.961 7.962 7.963 7.964 2-965 2.966 2967 2.968 2969 Z970 Z971 Z9N Z973 Z974 2975 2976 2978 Z.979 7.980 7.982 2.984 7.985 2.986 7-989 Disabled ramps, signs & features Paths Pavements Roads Schedules SERVICES AND UTILITIES — (General) Water main Sewer systems Storm sewers Gas main Electricity main Lighting main ‘Communication, telecom, cabling, main Fire services main Schedules HARDSCAPE ~ (General) Fencing Walls Gates, barriers, bollards Benches, seats Decks and bridges Street furniture, waste: Lighting Schedules SPECIAL LANDSCAPING ~ (General) Sports facilities Lakes ‘Wetlands, special areas, Shed, summer-house Schedules 990 ENVIRONMENTAL ~ (General) Z.991 Slope 2-992 Aspect -998 Soils and geology 7-994 Land use 7-995 Vegetation and ground cover 2.996 Wildlife 7.998 Air and sound quality Z.999 Climace, wind, shadows 7.0 SUBMISSION OF RECORD/AS BUILT DRAWINGS (On the completion of any project or alteration, all as built drawings must be forwarded to the CAD team for inclusion into the drawing database. tis the Project Managers responsibility to ensure all recordi/as built drawings are delivered to the CAD Team electronically. ‘All drawings for any project including GA plans, sections, elevations, details, schematics and services drawings must be produced and submitted in an un-locked AutoCAD .DWG format electronically on CD or by e-mail witha relevant index/issue sheet. Estates and Facilities currently use AutoCAD 2006. AIICD's should be clearly labeled with the Project details, date and version of AutoCAD used. Please ensure that all drawings have been produced to the guidelines of this CAD document. Derails of any revision history must be shown on any issued drawing. 8.0 USE OF STANDARD SYMBOLS. 8.1 Mechanical & Electrical Symbols Simplified versions of the British Standard M&E symbols have been created for use on Estates and Facilities drawings as British Standard CAD symbols are considered too detailed to be successfully used on drawings at scales greater than 1:100. They are available electronically as Blocks from the Estates and Facilities CAD Team and on the J\Estates\Everyone\Drawings\Standard M&E CAD Symbols No other symbol should be used, unless agreed by the Project Manager and the CAD team. All symbols inserted into mode! space will need to be scaled in at the scale of the drawing and be inserted on the appropriate layer. 8.2 MECHANICAL & ELECTRICAL SYMBOLS INDEX M&E Symbol Blocks can be Located in the following folder on the Estates and Facilites J Drive: ‘HV Estates\ Everyone\ Drawings\ Estates 8 Facilities CAD Standards\ Standard M&E CAD Symbols. EPOO1 a SOCKET DUTLET ‘N’ DENOTES No. OF GANGS ‘x’ DENOTES RATING IN AMPS EP002 A FLOOR MOUNTED SOCKET OUTLET TYPE AS DESCRIBED P003 (i SWITCHED SOCKET QUTLET \N’ DENOTES No, OF GANGS ‘x’ DENDTES RATING IN AMPS Pp EPo04 af WEATHERPROOF SOCKET OUTLET econ a SOCKET OUTLET TO BS 4343 ANY TYPE ‘N' DENOTES VOLTAGE & RATING Feooe A SOCKET OUTLET TO BS 4343 WITH INDICATING LaMP jy SWITCHED SOCKET OUTLET TO BS 4343 WITH EPo07 At TwO POLE SWITCH Epoos a FUSED CONNECTION UNIT WITH FLEX OUTLET EP009 tS switenen ruse CONNECTION UNIT WITH FLEX OUTLET FUSED CONNECTION UNIT WITH INDICATING LAMP EPato BR AND FLEX QUTLET SWITCHED FUSED CONNECTION UNIT WITH INDICATING LAMP EPoll ad AND FLEX QUTLET Epoie x SWITCHED COOKER CONTROL UNIT WITH INDICATING LAMP SWITCHED COOKER CONTROL UNIT WITH INDICATING LAMP EPoi3 AND SWITCHED SOCKET DUTLET WITH INDICATING LAMP SWITCH DISCONNECTOR RATING AS DETAILED EPo14 |, *S’ DENOTES SWITCH DISCONNECTOR FUSE °F’ DENOTES FUSED DISCONNECTOR SWITCH Epos a FUSED CONNECTION UNIT EPOIG CS switenen ruse connection untr EPoI7 a FUSED CONNECTION UNIT WITH INDICATING LAMP EPois cf SWITCHED FUSED CONNECTION UNIT WITH INDICATING LAMP Praia) SOCKET DUTLET WITH ISOLATING TRANSFORMER ‘N’ DENOTES RATING Project Scale Page: UNIVERSITY OF swonosmees | _ws_| _” Southampton POWER - INDEX | OF 3 JAN 07 Eats and Facies Telephone +44 (0}25 8089 4010 win ostate.coton acu eP020 BATTERY EP021 UNINTERUPTED POWER SUPPLY UNIT EPoze cONTACTOR EP023 ay TV OUTLET EPoe4 €& CLOCK OR SLAVE CLOCK eP025 © MASTER CLOCK EP026 @® TIME SWITCH CLOCK ePoe7 co MECHANICAL CONTROL PANEL, cpoze JUNCTION BOX EPo29 tL ee €P030 [Fc] FAN coNTROLLER €P031 hed tl! — CA) Immersion HeaTER P033 [WTR] ELECTRIC HEATER €P034 @m) WATER HEATER £P035 [Ho] —-HanD pRvER £P036 RESISTOR EP037 —{}/ capacrror Epos HK variaBLe capacitor Prose Sea STANDARD SYMBOLS NTS Drawing Tite POWER - INDEX 2 OF 3 * _ Southampton Dste: JAN 07 Estates and Facies ‘Telephone +4 (0}28 8059 4010 wwzestales.soton.ac.uk EP039 ecoon INDUCTOR Ga recA VARIABLE CONDUCTOR EP041 a=p CONNECTING LINK ena —@mmm- PLUG AND SOCKET Epo43 —os— NORMALLY OPEN CONTACT (MAKE CONTACT? EPo44 NORMALLY CLOSED CONTACT — — = CIRCUIT LINE CABLES/CABLE ROUTE INSTALLED DN SURFACE ————"_ TYPES AS _DETAILED ON DRAWING = CABLES/CABLE ROUTE INSTALLED BELOW FLOOR TYPES AS DETAILED ON DRAWING — — — CABLES/CABLE ROUTE INSTALLED ABOVE CEILING TYPES AS DETAILED ON DRAWING acre SYMBOLS a oD S hampto = = outhamp : tates and Facies ieee uence | _JAN 07 | stphone +4 (025 S88 S01 tn elas son ack Epoo1 Fa FUSE SWITCH DISCONNECTOR EDo02 =a SWITCH DISCONNECTOR FUSE 0 D003 \ CHANGE OVER SWITCH EDo04 “a SWITCH DISCONNECTOR £D00S wt MINIATURE CIRCUIT BREAKER ED006 oa CIRCUIT BREAKER D007 CIRCUIT BREAKER FOR BASIC DIAGRAMS ONLY Epos oS CONTACTOR EDOIS 8 THREE PHASE TRANSFORMER (NEUTRAL BOUGHT OUT> EDOIG (Y) THREE PHASE TRANSFORMER (4 TAPPINGS? EDOI7 (2) N THREE PHASE TRANSFORMER (ON LOAD TAP CHANGER? fos fee is UNIVERSITY OF STANDARD SYMBOLS NTS 20 South am ton ELECTRICAL - INDEX | OF 2 JAN 07 Escates and Fits Telephone +44 (0}28 8089 4010 wn. otatos.soton.acuk Epos ELECTRICAL MOTOR FINAL MCB OR FUSE DISTRIBUTION BOARD MAIN SWITCHBOARD OR DISTRIBUTION BOARD MECHANICAL CONTROL PANEL ED019 ELECTRICAL GENERATOR Epo20 AUTO TRANSFORMER Epoe1 CURRENT TRANSFORMER Epoze INDUCTOR Epoe3 EARTHING POINT epoes ISOLATOR SWITCH ep02s SWITCH FUSE UNIT ep026 CONTACTOR €p027 poze Epos ELECTRICITY METER D030 Project. Seale Page STANDARD SYMBOLS Drawing Tite Date ELECTRICAL - INDEX 2 OF 2 “s_|"_| Southampton 7 sae nd aces a Telephone +44 (0)23 8059 4010 www.estates.soton.ac.uk Fao. Faoo2 Faao3 Faooa Faaos Fa006 Faoo7 Favs Fav09 Fao FAOlL Fao Faaia Fao4 Faals Fagie Faol7 Faas, Fao19 SMOKE DETECTOR HEAT DETECTOR ASPIRATING DETECTOR BEAM SMOKE DETECTOR TRANSMITTER BEAM SMOKE DETECTOR RECEIVER BEAM SMOKE DETECTOR MIRROR INFRA-RED POINT-TYPE FLAME DETECTOR FLAME DETECTOR GAS DETECTOR FUSIBLE LINK DETECTOR INTERFACE UNIT ZONE MONITOR UNIT MAGNETIC DOOR HOLDER ZONE ISOLATOR MODULE MANUAL CALL POINT BELL ELECTRONIC/SQUNDER VISUAL ALARM bP BR > DPP. UPS: TELEPHONE (SOCKET) TELEX OUTLET TELEPHONE PAYPHONE DATA CABLING FACILITY *2' DENOTES TWIN DATA OUTLET JUNCTION BOX DATA PATCH PANEL UNINTERUPTED POWER SUPPLY CABLES/CABLE ROUTE INSTALLED ON SURFACE TYPES AS DETAILED ON DRAWING CABLES/CABLE ROUTE INSTALLED BELOW FLOOR TYPES AS DETAILED ON DRAWING CABLES/CABLE ROUTE INSTALLED ABOVE CEILING TYPES AS DETAILED ON DRAWING Proyect STANDARD SYMBOLS Seale Page: Drawing Tite: DATA & TELECOM - INDEX “s__"_}] Southampton Date: JAN 07 ces and Facies Telephone +44 (0925 6089 4010 twnrestates. soln acuk SE001 MAGNETIC DOOR HOLDER SE002 PUSHBUTTON ‘P’ DENOTES PAN SE003 PTZ CCTV CAMERA ‘T’ DENOTES TILT ‘Z’ DENOTES ZOOM SE004 PASSIVE INFA-RED DETECTOR SE00S AP INTRUDER ALARM PANEL SE006 PSU POWER SUPPLY UNIT SEO07 — ACCESS CONTROL SWIPE READER SE008 EM EMERGENCY GREEN MANUAL CALL POINT SE009 KP INTRUDER ALARM KEY PAD SE010 DOOR CONTACT SEO ‘MPX. MULTIPLEXER FOR CCTV SE012 VCR VIDEO RECORDER SE013 MON MONITOR FOR CCTV SE014 DvST DVST TRANSMISSION SYSTEM FOR CCTV SEOIS: ss SEQUENTIAL SWITCHER UNIT FOR CCTV SEO16 SAP ACCESS CONTROL AND ALARM PANEL SEOI7 MECHANICAL SECURITY KEY PAD SEO1S: NODE) INTRUDER ALARM ZONAL NODE Poe ale > aoa) SYMBOLS . a a S hampto — = outnhampton SECURITY - INDEX | OF 2 JAN 07 Esates and Fates Telpnone +48 (0)28 8059 4010 min estates soton ac. VIDED ENTRY SYSTEM VIDEO ENTRY HANDSET VIDED ENTRY SPEECH PANEL SEO19 v sE020 vw SE021 vs Project Seale Page! STANDARD SYMBOLS NTS. 33 Drawn Tite Date! SECURITY - INDEX 2 OF 2 JAN 07 UNIVERSITY OF Southampton cDMMH1 mon EXISTING DUCTWORK DISTRIBUTION RETAINED UNDER THIS CONTRACT CONTAINS ASBESTOS BASED MATERIALS BETWEEN FLANGES AND AT PLANT CONNECTIONS Cone (od, ACCESS TO PLANT AND. EQUIPMENT IS. RESTRICTED S OBSTRUCTIONS AT HEAD HEIGHT ARE PRESENT PIPEWORK WITHIN THIS PLANTROOM CONTAINS STEAM CDMMH3 AS A HEATING MEDIUM. SERVICES SHALL BE_ ISOLATED PRIOR TO COMMENCING ANY WORKS ON DISTRIBUTION EQUIPMENT WITHIN THIS PLANTROOM IS PROGRAMMED n pan TO START/STOP UNDER DICTATES OF AUTOMATIC oa CONTROL. ALL PLANT SHALL BE ELECTRICALLY ISOLATED BEFORE UNDERTAKING ANY WORKS. ALL PLANT AND EQUIPMENT HAS BEEN PROVIDED WITH LOCAL ISOLATION POINTS. THE MECHANICAL CONTROL fa PANEL IS PROVIDED WITH INTERLOCKED ISOLATOR OE WHICH WILL SHUTDOWN ALL EQUIPMENT. FOR DETAILS OF ISOLATION OF MECHANICAL CONTROL PANEL REFER TO OPERATIONAL MANUAL. CDMA ® MECHANICAL PLANT ELECTRICAL ISOLATION coma ISOLATING VALVE FOR STEAM HEATING DISTRIBUTION Project Seale age: UNIVERSITY OF smonosneos | ws _|_™ | Southampton CDM - INDEX JAN 07 eats and Facies “elaphone v4 (0)23 8089 4010 twincostatas.solonacuk mvoor SILENCER mvoo2 1 BELL MOUTH Mvoo3 ® MOTOR Mvoo4 ey FAN UNIT (AXIAL) Mvoos TWIN FAN UNIT (AXIAL) Mvo06 @ CENTRIFUGAL FAN UNIT Mvoo7 [) CENTRIFUGAL FAN UNIT vos A HEATER BATTERY Mvoog 8 COOLER BATTERY Mvo10 ww PANEL FILTER mvott {\/\/) BAG FILTER Mvo12 — | HUMIDIFIER MVO13 —S HUMIDIFIER HANDED vor access] ACCESS PANEL Mvois [seacer| SPACER Mvo16 L] MIXING BOX mvor7 ==}, DAMPER MANUAL Mvo18 FS=s4}0 DAMPER MOTORISED mvo1g E24}9 DAMPER PNEUMATIC nT STANDARD SYMBOLS Tie ne: S outhampto a =< ampton eon Ree _JAN 07 | seohone +44 (0255083 4010 meats ston ack mvo20 VCD y VOLUME CONTROL DAMPER MvOo21 I DAMPER FIRE Mvo22 {l DAMPER SMOKE Mvo23 § DAMPER NON RETURN Mvo24 q DAMPER NON RETURN HANDED Mvo2s CROSS TALK ATTENUATOR \ Mvo26 Ye INLET LOUVRE Mvo27 Yo DISCHARGE LOUVRE — BE] Fan unit xe FLOW Mvo29 [ex[eK) FAN UNIT MIXED FLOW Mvo30 {BE} ouctwork FLEXIBLE CONNECTION Mvo3t = NATURAL CONVETOR MVO032 aS) FAN CONVECTOR Pred Saale Faas RersniOr smmowosmaos | ws |_| Southampton DUCTWORK - INDEX 2 OF 2 JAN 07 aces nd Faces INDEX20F2 | Telophone +48 (0)25 60504010 sas ston ack MPoo1 % ISOLATING VALVE MP0O2 sy LOCKSHIELD VALVE MP003 » BASIC VALVE (NORMALLY CLOSED) MPOo4 va BASIC VALVE (WHEEL STRAIGHT) MPOOS n NON RETURN VALVE MP006 x ANGLE VALVE MPoo7 A ANGLE VALVE MP008 x PRESSURE RELIEF VALVE MP009 x PRESSURE RELIEF VALVE sc MPo10 Ba STOP cock MPom og FIRE VALVE MPO12 Pl 3 WAY VENT COCK MPO13 mo GLOBE VALVE MPo14 ba BALL VALVE MPOIS aR BASIC CONTROL VALVE (PNEUMATIC) MPOI6 & 2 PORT CONTROL VALVE (MOTORISED) MPOI7 R 3 PORT CONTROL VALVE Rv MPO18 I PRESSURE REDUCING VALVE MPO19 NO STRAINER Project Seale Poe UNIVERSITY OF STANDARD SYMBOLS NTs 37 S th ti Soa 7 outhampton PIPEWORK - INDEX | OF 4 JAN 07 Estates and Faces = Telephone +44 (0}28 8089 4010 smi osats.colonacuk MP020 MPO21 Mpo22 MPO23 Mpa24 MPo25 MPO26 MPO27 MPO28 MPo23 MPO30 MPO3t MPOs2 MPOS3 MPO34 MPO35 MPOS6 MPO37 MPO38 A Ne @rmazrTx

Vous aimerez peut-être aussi