2. Cable Specification
2.1 Sheath marking
SGFC
GYTA53
xxB1
SGFC
: Manufacturers name
GYTA53
: Cable type
xxB1
: Cable size
2012
: Manufacturing year
XXXXM
: Mark of meters
2012
XXXXM
Specification
Single mode
PAGE 5
Fiber material
Doped silica
Attenuation coefficient
@ 1310 nm
@ 1550 nm
0.36 dB/km
0.22 dB/km
0.05 dB
1260 nm
Zero-dispersion wavelength
1300 ~ 1324 nm
Zero-dispersion slope
0.093 ps/(nm2.km)
Chromatic dispersion
@ 1288 ~ 1339 nm
@ 1271 ~ 1360 nm
@ 1550 nm
0.2 ps/km1/2
9.20.4 um
0.5 um
Cladding diameter
125.0 0.7 um
Cladding non-circularity
1.0%
245 10 um
Temperature dependence
0oC~ +70oC @ 1310 & 1550nm
0.1 dB/km
* PMDQ is a link of 20 cable sections (M) and a probability level of 0.01% (Q).
:-40oC to +60oC
:-50oC to +60oC
Item
Test Method
:-20oC to +50oC
Acceptance Condition
Tensile Strength
- Load: 3,000 N
IEC 794-1-E1
Crush Test
IEC 794-1-E3
PAGE 5
- Points of impact: 5
3
Impact Resistance
IEC 794-1-E4
Repeated Bending
- Load: 250 N
IEC 794-1-E6
- No. of cycle: 30
- Length: 1 m
5
Torsion
IEC 794-1-E7
- Load: 250 N
- Twist angle: 90
- No. of cycle: 10
- Height of water: 1 m
- Sample length: 3 m
o
o
o
o
+20 C-40 C+60 C +20 C
- Number of cycle: 2
Compound Flow
IEC 794-1-E14
- Sample length: 30 cm
- Temp: 70C 2C
- No compound flow
- Time: 24 hours
- On line test
- 9t KV (t-sheath thickness)
ew
Technical parameters:
Items
Index
Core No.
2-36
38-60
62-72
74-84
86-96
98-108
Diameter /mm
13.5
14.1
14.6
15.4
16.1
16.8
17.5
18.2
18.9
195
210
225
251
270
290
310
335
360
3000/1000
3000/1000
N/100mm
0.36dB/km@1310nm,
Operating temperature
-40+60
PAGE 5
Application
Used for core network, city area network and access network. Its suitable for direct buried , also inside duct or cable
tunnel installation.
Product Characteristic
1.
2.
Reasonable structure design and precise control for over length ensuring excellent characteristics of mechanical
5.1.1 Each single length of cable shall be wound on an iron stand-wooden composite or pure wooden
drum.
5.1.2 Standard drum length is 3000m 1%, or it can be delivered according to customer requirement but
not longer than 6000m with a tolerance.
5.1.3 Covered by plastic buffer sheet.
5.1.4 Sealed by strong wooden battens.
5.1.5 At least 1m of inner end of cable should be reserved for testing.
Roll-direction arrow;
Drum number;
Drum length;
PAGE 5
Caution plate indicating the correct method for loading, unloading and convey the cable;
Other customer information such as contract no., project no., and delivery destination. (if needed)
Quality certificate;
Test report.
SPEC. END