Vous êtes sur la page 1sur 5

GYTA53: Metallic Strength Member Stranded Loose Tube Filled Al-PE Inner Sheath

Corrugated Steel Armored PE Outer Sheath Outdoor OFC for Communication


1 Cable Structure.

2. Cable Specification
2.1 Sheath marking

SGFC

GYTA53

xxB1

SGFC

: Manufacturers name

GYTA53

: Cable type

xxB1

: Cable size

2012

: Manufacturing year

XXXXM

: Mark of meters

2012

XXXXM

*The marking is printed every 1 meter


2.2 The color of marking is white, but if the re-printing is necessary, the yellow color marking shall be printed
newly on a different position.
2.3 Each cable ends are sealed with heat shrinkable end caps to prevent water ingress.

3. Performance of Cabled Optical Fiber


The performance of cabled single mode optical fiber (ITU-T Rec. G.652D)
Item
Type of fiber

Specification

Single mode

PAGE 5

Fiber material

Doped silica

Attenuation coefficient
@ 1310 nm
@ 1550 nm

0.36 dB/km
0.22 dB/km

Point discontinuity @ 1310 & 1550 nm

0.05 dB

Cable cut-off wavelength

1260 nm

Zero-dispersion wavelength

1300 ~ 1324 nm

Zero-dispersion slope

0.093 ps/(nm2.km)

Chromatic dispersion
@ 1288 ~ 1339 nm
@ 1271 ~ 1360 nm
@ 1550 nm

3.5 ps/(nm. km)


5.3 ps/(nm. km)
18 ps/(nm. km)

PMDQ (Quadrature average*)

0.2 ps/km1/2

Mode field diameter @ 1310 nm

9.20.4 um

Core / Cladding concentricity error

0.5 um

Cladding diameter

125.0 0.7 um

Cladding non-circularity

1.0%

Primary coating diameter

245 10 um

Proof test level

100 kpsi (=0.69 Gpa), 1%

Temperature dependence
0oC~ +70oC @ 1310 & 1550nm

0.1 dB/km

* PMDQ is a link of 20 cable sections (M) and a probability level of 0.01% (Q).

4. Performance of Optical Cable


4.1 Cable bending radius: 10 x cable diameter (static)
20 x cable diameter (dynamic)

4.2 Application temperature range


Operating temperature range

:-40oC to +60oC

Storage / Transport temperature range

:-50oC to +60oC

Installation temperature range


4.3 Main mechanical & environmental performance test
S/N

Item

Test Method

:-20oC to +50oC

Acceptance Condition

Tensile Strength

- Load: 3,000 N

- Loss change 0.1 dB @1550 nm

IEC 794-1-E1

- Length of cable under load: 50 m

- No fiber break and no sheath damage.

Crush Test

- Load: 3,000 N/100 mm

- Loss change 0.1 dB @1550 nm

IEC 794-1-E3

- Load time: 1min.

- No fiber break and no sheath damage.

PAGE 5

- Points of impact: 5
3

Impact Resistance
IEC 794-1-E4

-Times of per point: 5

- Loss change 0.1 dB @1550 nm

- Impact energy: 10 N.m

- No fiber break and no sheath damage.

- Radius of hammer head: 12.5mm


- Impact rate: 2 sec/cycle
- Bending radius: 20 x cable diameter

Repeated Bending

- Load: 250 N

- Loss change 0.1 dB @1550 nm

IEC 794-1-E6

- Flexing rate: 3 sec/cycle

- No fiber break and no sheath damage.

- No. of cycle: 30
- Length: 1 m
5

Torsion
IEC 794-1-E7

- Load: 250 N

- Loss change 0.1 dB @1550 nm

- Twist rate: 1 min/cycle

- No fiber break and no sheath damage.

- Twist angle: 90
- No. of cycle: 10

Water Penetration Test


IEC 794-1-F5B

- Height of water: 1 m

- No water shall have leaked from the

- Sample length: 3 m

opposite end of cable.

- Test time: 24 hours


- Temperature step:

o
o
o
o
+20 C-40 C+60 C +20 C

Temperature Cycling Test


IEC 794-1-F1

- Loss change 0.05 dB/km@1550 nm

- Time per each step: 24 hrs

- No fiber break and no sheath damage.

- Number of cycle: 2

Compound Flow
IEC 794-1-E14

Sheath High Voltage Test

- Sample length: 30 cm
- Temp: 70C 2C

- No compound flow

- Time: 24 hours
- On line test

-No sheath breakdown

- 9t KV (t-sheath thickness)

ew
Technical parameters:
Items

Index

Core No.

2-36

38-60

62-72

74-84

86-96

98-108

Diameter /mm

13.5

14.1

14.6

15.4

16.1

16.8

17.5

18.2

18.9

Unit weight /Kg/km

195

210

225

251

270

290

310

335

360

Max. Allowable tension


Max. Allowable crush
Attenuation

3000/1000
3000/1000

110-120 122-132 134-144

(short term/long term)

N/100mm

0.36dB/km@1310nm,

(short term/long term)


0.22dB/km@1550nm

Minimum bend radius

During installation 20DDuring Service 10D

Operating temperature

-40+60

PAGE 5

Application

Used for core network, city area network and access network. Its suitable for direct buried , also inside duct or cable
tunnel installation.

Product Characteristic

1.

With good crush resistance and moisture-proof performance

2.

Reasonable structure design and precise control for over length ensuring excellent characteristics of mechanical

tensile strain and environment temperature


High strength loose tube material with good performance of hydrolysis resistant, special tube filling compound ensure a
critical protection of fiber.

5. Packing and Marking


5.1 Packing

5.1.1 Each single length of cable shall be wound on an iron stand-wooden composite or pure wooden
drum.
5.1.2 Standard drum length is 3000m 1%, or it can be delivered according to customer requirement but
not longer than 6000m with a tolerance.
5.1.3 Covered by plastic buffer sheet.
5.1.4 Sealed by strong wooden battens.
5.1.5 At least 1m of inner end of cable should be reserved for testing.

5.2 Drum marking


-

Manufacturer name & logo;

Manufacturing year and month;

Roll-direction arrow;

Cable outer end position indicating arrow;

The word OPTICAL FIBER CABLE;

Cable type and size;

Drum number;

Drum length;

Gross / net weight;

PAGE 5

Origin, The word MADE IN CHINA;

Caution plate indicating the correct method for loading, unloading and convey the cable;

Other customer information such as contract no., project no., and delivery destination. (if needed)

5.3 Cable quality certificate documents


-

Quality certificate;

Test report.

SPEC. END

PAGE 5