BATTERY SYSTEMS
RESERVE
POWER
Long Life
Thick lead-calcium positives grids in the
PowerSafe V series and Thin Plate Pure
Lead (TPPL) technology in PowerSafe
SBS batteries have a proven track record
in telecommunications applications
around the world.
Thermal Control
Monobloc design provides each cell with
full side wall exposure for efficient bloc
cooling.
The shelves are perforated to allow air
flow through the stack for efficient
system cooling.
Flexibilty
If new equipment is added to a site
increasing the power consumption additional battery strings can be added
to match the new load.
Easy Handling and Maintenance
Lifting handles make handling easy.
Front terminals make installation and
maintenance quick and simple.
Shelves
EnerSys SpaceSaver shelves in 19 or
23 equipment racks provide a well
ventilated platform for high capacity
battery systems.
Bus Bar
Rack mounting bus bars and battery-tobus bar cable kits provide a convenient
method and location for connecting
multiple strings in parallel.
New or Retrofit Installations
EnerSys SpaceSaver complete Rack
Mounting Battery Systems or
components are easy to order.
Refer to the String Configuration and
Ordering Guide sections for full
information on ordering EnerSys
SpaceSaver Rack Mounting Battery
Systems for new installations or
individual components for replacement
or retrofit applications.
Compact Installation
PowerSafe V and PowerSafe SBS front
terminal battery capacity ranges from
92 to 190Ah. A 48V string or 2 x 24V
strings per shelf provides high energy
density.
PowerSafe V Front Terminal Battery Performance Data
Nominal Performance at 77F (25C)
Model
12V92F-FT
12V100F
12V125F
12V155FS
12V170F
Model
12V92F-FT
12V100F
12V125F
12V155FS
12V170F
End Vpc
1 Hr
2 Hrs
1.75
1.75
1.75
1.75
1.75
64.8
66.3
66.3
107.7
118.2
36.6
38.6
48.7
62.3
67.0
End Vpc
1 Hr
1.75
1.75
1.75
1.75
1.75
126.2
124.4
163.5
206.3
223.9
8 Hrs
10 Hrs
11.5
12.5
15.7
19.4
21.3
9.4
10.4
12.8
15.9
17.4
10 Hrs
72.6
72.9
94.9
119.4
129.3
22.9
24.4
31.3
37.7
41.5
18.9
20.3
25.2
31.1
34.2
8 Hrs
10 Hrs
11.4
21.6
24.2
9.39
17.4
19.9
10 Hrs
72.7
143.1
163
18.9
35.5
39.7
26.0
27.9
35.1
44.4
47.8
51.7
52.8
68.6
86.0
92.6
20.2
22.0
28.1
34.9
37.5
40.5
42.5
54.0
67.7
73.2
16.6
18.4
23.3
28.9
31.2
33.4
35.6
45.5
56.2
60.8
End Vpc
1 Hr
2 Hrs
1.75
1.75
1.75
64.9
124.3
138.2
36.7
72.0
80.3
End Vpc
1 Hr
1.75
1.75
1.75
126
244.2
279.8
www.enersys.com
Model
SBS C11F
SBS170F
SBS190F
51.8
102.2
116
20.2
39.9
44.6
40.5
79.9
90.4
16.7
32.8
36.7
33.5
65.7
74.3
23.0
43.4
48.6
Shelf
Part No.
SC11-U*
SVF23
SVF19
SVF23
SVF23
SVF23
SVF23
SC11-U*
SVF23
SVF23
Rack
19
23
Bloc to Bloc
Connector
Spacing
In
Width
In
String
Depth
In
C11CONN
VFCONN
0.39
0.37
17.2
20.9
1463083
0.08
16.8
VFCONN
VFCONN
VFCONN
C11CONN
VFCONN
VFCONN
0.37
0.37
0.37
0.39
0.37
0.37
20.8
20.8
20.8
17.7
20.8
20.8
16.5
22
22
22
22
22
22
16.5
22
22
Maximum
# Shelves
Strings
Per Shelf
Shelf to Shelf
Spacing (Min)
In
6
7
1
1
11.4
10.0
13.4
5
5
7
6
5
5
1
1
1
1
1
1
13.4
13.4
10.0
11.4
13.0
13.8
Maximum
# Shelves
Strings
Per Shelf
Shelf to Shelf
Spacing (Min)
In
6
7
2
2
11.4
10.0
13.4
5
5
7
6
5
5
2
2
2
2
2
2
12.0
13.4
10.0
11.4
13.0
13.8
24V Systems
Model
12V92F-FT
12V100F
12V125F
12V155FS
12V170F
12VX100F
SBS C11F
SBS170F
SBS190F
Shelf
Part No.
SC11-U*
SVF23
SVF19
SVF23
SVF23
SVF23
SVF23
SC11-U*
SVF23
SVF23
Rack
19
23
Bloc to Bloc
Connector
Spacing
In
Width
In
String
Depth
In
C11CONN
VFCONN
0.39
0.37
8.6
10.2
1463083
0.08
8.4
VFCONN
VFCONN
VFCONN
C11CONN
VFCONN
VFCONN
0.37
0.37
0.37
0.39
0.37
0.37
10.2
10.2
20.8
8.5
10.2
10.2
16.5
22
22
22
22
22
22
16.5
22
22
www.enersys.com
SC11-U in 19 Rack
With a depth of only 16.5 the
PowerSafe SBS C11F and 12V92F-FT
are ideal for sites with narrow rooms
such as customer premises
Fast-Disconnect Cables
The Fast-Disconnects allow single
strings to be isolated during
installation or maintenance procedures
Ordering Guide
System and Component Selection Guide
Part Number
Description
Part Number
Description
PR
VF1CKA
PR19
VF2CKA
SVF23
VF3CKA
SVF19
VF4CKA
SC11-U
VF5CKA
VF6CKA
VF7CKA
BB23
BB19
Notes: For cables without the Fast-Disconnect omit the letter A from the Part Number.
Cable numbering system is based on String 1 being at the bottom of the rack.
Voltage
Shelves
1-7
Rack
Type
Ah
Type
24 = 24V
92
S = SBS
See
19 = 19
48 = 48V
100
V=V
configuration
23 = 23
125
VX = VX
tables for
155
maximum
170
shelves per
190
rack
Example:
Shelf
Type
Bus Bar
Fast
Disconnect
S1 = SVF19
1 = BB19
S2 = SVF23
2 = BB23
S3 = SC11-U
48-100 VX 4 23 S2 2 A
48
100
VX
4
23
S2
2
A
48 Volt system
100 Ah Capacity
PowerSafe 12VX100F battery
4 Strings
23 Equipment Rack
SVF23 Shelves
BB23 Bus Bar Omit if not required
Fast Disconnect - Omit if cables are not required
WALL
84.0
Min
Dimension
PowerSafe V FT Models
16.5
22.0
22.0
22.0
22.0
16.5
22.0
22.0
11.4
10.0
13.4
12.0
13.4
11.4
13.0
13.8
6.5
10.5
10.5
10.5
10.5
6.5
10.5
10.5
3.5
FLOOR
Distributed by:
www.enersys.com
Global Headquarters
EnerSys
P.O. Box 14145
Reading, PA 19612-4145
USA
Tel: (610)208-1991
(800)538-3627
Fax: (610)372-8613
EnerSys de Mexico
S.A. de C.V.
Ave. Presidente Juarez 74-A
Col. Bellavista C.P. 54080
Tlalnepantam Estado
de Mexico
Tel: (52-55)2628-0504
Fax: (52-55)5362-7774
Publication No: US-FTSP-TS-001 - September 2008 - Subject to revisions without prior notice. E.&O.E.
48 - XXX - V - X - 23 - S1 - 1 - A