Ship Name
Diesel Engine Manufacturer
Year
Month
Jacket
Capacity,
tons:
Date
1-3
> or = 2700
Nitrite as ppm
2520
NO2
2340
2160
Normal Level
1980
1500 - 2400ppm
1800
1620
1440
1260
1080
900
< or = 720
Chloride
ppm Cl
Normal Level
max 50ppm
HT
4-7
> or = 100
80
60
40
20
0
Piston
Date
1-3
> or = 2700
Nitrite as ppm
2520
NO2
2340
2160
Normal Level
1980
1500 - 2400ppm
1800
1620
1440
1260
1080
900
< or = 720
Chloride
ppm Cl
Normal Level
max 50ppm
Chloride
ppm Cl
Normal Level
max 50ppm
> or = 100
80
60
40
20
0
pH
Dieselguard NB kg
Rocor NB Liquid ltr
Makeup ltr
Comments:
4-7
> or = 100
80
60
40
20
0
pH
Dieselguard NB kg
Rocor NB Liquid ltr
Makeup ltr
Fuel Valves
Date
1-3
> or = 2700
Nitrite as ppm
2520
NO2
2340
2160
Normal Level
1980
1500 - 2400ppm
1800
1620
1440
1260
1080
900
< or = 720
LT
Capacity,
tons:
pH
Dieselguard NB kg
Rocor NB Liquid ltr
Makeup ltr
Capacity,
tons:
IMO/Lloyds No.
Shore
Distilled
Mixed
Dieselguard NB
Rocor NB Liquid
Others
4-7
Aux. Generators
Capacity,
tons:
Date
1-3
> or = 2700
Nitrite as ppm
2520
NO2
2340
2160
Normal Level
1980
1500 - 2400ppm
1800
1620
1440
1260
1080
900
< or = 720
Chloride
ppm Cl
Normal Level
max 50ppm
> or = 100
80
60
40
20
0
pH
Dieselguard NB kg
Rocor NB Liquid ltr
Makeup ltr
4-7
Owner
Boiler Maker
Evaporation rate-kg/h
Year
Type
Pressure, bar
Month
Make up
Boiler Identification:
Liquitreat
P. Alkalinity
ppm as CaCO3
100 - 300
Day 1
> or = 350
330
310
290
270
250
230
210
190
170
150
130
110
90
< or = 70
Boiler pH
Over 11.0
9.5 - 11.0
Below 9.5
Sample appearance
Cloudy
Clear
Coloured
Condensate pH
Limits
8.3 - 9.0
"Condensate Control"
Dosage in Liter
Condensate Chloride
Usually below 20 ppm
Should be kept as
low as possible
Hotwell
Temp oC
Comments:
Shore
Distilled
Ton
Mixed
Dosage in Liter
Boiler Chlorides
Max 200 ppm as Cl
Should be kept as
low as possible
(Usually below 50)
Blowdown Bottom/Top
Water volume
> or = 260
220 - 240
180 - 200
140 - 160
100 - 120
60 -80
0 - 40
> or = 9.2
8.8 - 9.0
8.3 - 8.6
7.0 - 8.0
< or = 6.0
> 80
60-80
40-60
20-40
0 - 20
> or = 90
81 - 90
70 - 80
61 - 69
< or = 60
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Owner
Boiler Maker
Evaporation rate-Kg/h
Year
Type
Pressure, bar
Month
Make up
Boiler Identification:
Hardness Control
Phosphate
ppm as PO4
Limits 20 to 50
100 - 150
40
30
20
10
0
> or = 170
150
130
110
90
< or = 70
Dosage in ml
M. Alkalinity
Boiler pH
Oxygen Control
Hydrazine ppm N2H4
limits 0.10 - 0.20
Over 2xP.Alk
Below 2xP.Alk
Over 11.0
9.5 - 11.0
Below 9.5
> or = 0.25
0.20
0.15
0.10
< or = 0.05
Dosage in Liter
> or = 0.40
0.35
0.30
0.25
0.20
0.16
0.12
0.08
< or = 0.04
Dosage in Liter
Boiler Chlorides
Max 200 ppm as Cl
Should be kept as
low as possible
(Usually below 50)
Blowdown Bottom/Top
Condensate pH
Limits
8.3 - 9.0
Condensate Control
Dosage in Liter
Condensate Chloride
Usually below 20 ppm
Should be kept as
low as possible
Hotwell
Temp oC
The higher the better
Comments:
Shore
Distilled
Ton
Mixed
Dosage in grammes
Alkalinity Control
P. Alkalinity
ppm as CaCO3
Water volume
> or = 260
220 - 240
180 - 200
140 - 160
100 - 120
60 -80
0 - 40
> or = 9.2
8.8 - 9.0
8.3 - 8.6
8.2
< or = 8.0
> 80
60-80
40-60
20-40
0 - 20
> or = 90
81 - 90
70 - 80
61 - 69
< or = 60
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Owner
Boiler Maker
Evaporation rate-Kg/h
Year
Type
Pressure, bar
Month
Make up
Boiler Identification:
Hardness Control
Phosphate
ppm as PO4
Limits 20 to 50
100 - 150
Day 1
> or = 70
60
50
40
30
20
10
0
> or = 170
150
130
110
90
< or = 70
Dosage in ml
M. Alkalinity
Boiler pH
Oxygen Control
Hydrazine ppm N2H4
limits 0.10 - 0.20
Over 2xP.Alk
Below 2xP.Alk
Over 11.0
9.5 - 11.0
Below 9.5
> or = 0.25
0.20
0.15
0.10
< or = 0.05
Dosage in Liter
> or = 0.40
0.35
0.30
0.25
0.20
0.16
0.12
0.08
< or = 0.04
Dosage in Liter
Boiler Chlorides
Max 200 ppm as Cl
Should be kept as
low as possible
(Usually below 50)
Blowdown Bottom/Top
Condensate pH
Limits
8.3 - 9.0
Condensate Control
Dosage in Liter
Condensate Chloride
Usually below 20 ppm
Should be kept as
low as possible
Hotwell
Temp oC
The higher the better
Comments:
Shore
Distilled
Ton
Mixed
Dosage in grammes
Alkalinity Control
P. Alkalinity
ppm as CaCO3
Water volume
> or = 260
220 - 240
180 - 200
140 - 160
100 - 120
60 -80
0 - 40
> or = 9.2
8.8 - 9.0
8.3 - 8.6
8.2
< or = 8.0
> 80
60-80
40-60
20-40
0 - 20
> or = 90
81 - 90
70 - 80
61 - 69
< or = 60
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Owner
Boiler Maker
Evaporation rate-kg/h
Year
Type
Pressure, bar
Month
Make up
Boiler Identification:
Autotreat
P. Alkalinity
ppm as CaCO3
100 - 300
Sample appearance
Oxygen Scavenger +
(Diethylhydroxylamine)
DEHA
limits: 0.08 - 0.30 ppm
Day 1
> or = 350
330
310
290
270
250
230
210
190
170
150
130
110
90
< or = 70
Over 11.0
9.5 - 11.0
Below 9.5
Cloudy
Clear
Coloured
> or = 0.40
0.35
0.30
0.25
0.20
0.16
0.12
0.08
< or = 0.04
Dosage in Liter
Boiler Chlorides
Max 200 ppm as Cl
Should be kept as
low as possible
(Usually below 50)
Blowdown Bottom/Top
Condensate pH
Limits
8.3 - 9.0
Condensate Chloride
Usually below 20 ppm
Should be kept as
low as possible
Hotwell
Temp oC
The higher the better
Comments:
Shore
Distilled
Ton
Mixed
Dosage in Liter
Boiler pH
Water volume
> or = 260
220 - 240
180 - 200
140 - 160
100 - 120
60 -80
0 - 40
> or = 9.2
8.8 - 9.0
8.3 - 8.6
7.0 - 8.0
< or =6.0
> 80
60-80
40-60
20-40
0 - 20
> or = 90
81 - 90
70 - 80
61 - 69
< or = 60
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
GENERAL RECOMMENDATIONS
TAKE THE SAMPLES ALWAYS FROM SAME PLACE AND LEAVE A FEW SECONDS TO DRAIN TO COLLECT A VALID SAMPLE.(FILTER IF TOO CLOUDY)
(BOILER: FROM MID OR BOTTOM - CONDENSATE: FROM HOTWELL, INSPECTION TK OR CONDENSER- COOLING: FROM RUNNING CIRCUIT.NOT FROM TK!)
COOL DOWN THE SAMPLES AS SOON AS POSSIBLE AND TEST IN THE NEXT 15-30 MINUTES, SAMPLES BELOW 21C !!!
USE DISTILLED WATER AS MAKE UP ONLY... USING A FEED WTR >50 PPM CHLORIDE WILL REDUCE TREATMENT EFFICIENCY DRASTICALLY.
TEST AT LEAST TWICE A WEEK AND FOR MEDDIUM PRESSURE BOILER... ANALYZE EVERYDAY
IF ANY REAGENT TABLET SHOW SPOT CONTAMINATION. THROW IT AWAY ...
ON ANY BOILER: CARRY OUT DAILY FLASH (INTENSE-FULL OPEN & BRIEF) BOTTOM BLOWDOWNS TO ELIMINATE SOLIDS PRECIPITATED BY CHEMICALS
THE TEMPERATURE OF HOTWELL TANK SHOULD BE THE HIGHEST POSSIBLE(95) TO REDUCE OXYGEN ABSORPTION (BY PASS CONDENSER IF NEEDED)
SEND THE LOGS REGULARY TO UNITOR FOR A PROPER TRACKING & ADVISE
PH PAPER STRIPS SHOULD BE IMMERSED FOR 20-30 SECONDS. USE REAGENT FOR BOILER & CONDENSATE SAMPLES
PH VALUES SHOULD BE RIGHT WHEN THE CHEMICAL RESERVE IS WITHIN LIMITS. IN CASE OF EXTERNAL CONTAMINATION CAN BE LOWER
IF PH IS LOWER THAN MINIMUN AND CHEMICAL RESERVE IS OK, ADD 50 ML PER TON OF ALKALINITY CTRL TO RESTORE THE NORMAL VALUES
IN THE COMMENTS CELL: PLS WRITE DOWN WHEN THE CHEMICAL PRODUCTS RUN OUT OF STOCK. TO UNDERSTAND LOW READINGS
THERE IS NO TREATMENT FOR HIGH CHLORIDE: CHANGE THE WATER AND FILL UP WITH PURE DISTILLED IS THE ONLY SOLUTION
IN THE COMMENTS CELL, PLS ADVISE THE FOLLOWING INFO:
WHEN A SUDDEN CHANGE OF NORMAL RUNNING CONDITION (IE. DRAIN DUE TO REPAIRS,MAINTENANCE, INSPECTION, BIG LEAKS, ETC)
IF AN OIL OR SEAWATER CONTAMINATION HAPPENS
IF A BOILER IS KEPT ON LAID-UP FOR SOME WEEKS, OR WHICH ONE WORKS AS MASTER OR SLAVE
PLS MENTION WHEN A BOILER RUNS AT FULL OUTPUT (TANKERSHIPS WHEN USING STEAM CARGO PUMPS)...ADD MORE CHEMICALS THAT DAY
WATER TREATMENT DOSING CHART FOR COOLING SYSTEMS & LOW PRESSURE BOILERS
TABLETS NITRITE CHLORIDE P ALKALINITY ROCOR NB DIESELGUARD NB LIQUITREAT/AUTOTREAT COMBITREAT
1
180
0
10 13.6
3.2
3.1
0.45
2
360
20
30 12.1
2.9
2.7
0.35
3
540
40
50 10.6
2.5
2.4
0.30
4
720
60
70 9.0
2.1
2.1
0.25
5
900
80
90 7.5
1.7
1.8
0.20
6
1,080
100
110 OK
OK
OK
OK
7
1,260
120
130 OK
OK
OK
OK
8
1,440
140
150 OK
OK
OK
OK
9
1,620
160
170 OK
OK
OK
OK
10
1,800
180
190 OK
OK
OK
OK
11
1,980
200
210 OK
OK
OK
OK
12
2,160
220
230 OK
OK
OK
OK
13
2,340
240
250 OK
OK
OK
OK
14
2,520
260
270 --OK
OK
15
2,700
280
290 --OK
OK
16
2,880
300
310 ----DOSING QUANTITIES ARE ADVISED TO BE MULTIPLIED BY TON OF EACH CIRCUIT TOTAL CAPACITY
Nitrite reserve will reach 1.800 ppm NO2 & Alkalinity reserve will reach 200 ppm CaCO3
If chloride reading is higher than 50 ppm Cl- in cooling circuits. Change water by distilled or raise NO2 till 2.880 ppm as a temporary solution
For boiler systems carry out daily bottom flash blowdowns. Increase time if chloride exceeds 50 ppm