Académique Documents
Professionnel Documents
Culture Documents
Product Features:
Voltage Programming
FEATURES
Constant Output Power
Load Sharing / Fault Redundant
Voltage Programming
Universal Input & International Certifications
Ideal for 2U or 3U applications
Built-in variable speed fan
BENEFITS
Ideal for battery backup architectures
Suitable for N+1 redundant operation
Designed for float charging VRLA batteries
Meets all worldwide standards
Offers high power density in 19 shelf
Low noise and increased reliability
SPECIFICATIONS
Input Voltage Range
Input Current Maximum
Inrush Current
Input Fuse
Power Factor
Efficiency
Output Power
Nominal Output Current
Output Voltage Range
Voltage Regulation
Ouput Ripple & Noise
Transient Response
Start-up Time
Hold-up Time
Remote on/off
Current Limit Protection
Over Voltage Protection
Over Temperature Protection
Operating Temperature
Output Power Good
Emissions
LED Indicators
Cooling
Shock & Vibration
Alarm & Monitoring
Overshoot 1V max. Recovery time: 4ms maximum (@ 50% load step and dl/dt <1A/s)
1sec typical (max. 3sec)
10msec at full load
ON: external 10k resistor. OFF: tied to 0V signal or open connection
36A
-59 to -60Vdc - latching, reset by remote OFF or line OFF during 20 sec.
Non latching; protection active at 110C internal temp., restart at 95C (typical)
-25C to +70C. Internal derating above 55C at 30W per C (-40C start up)
PNP open collector (0V signal = +out), when GOOD: 10V/5mA
Level Class B (FCC and CISPR compliant) - EN55022 lebel B, CE Marking Level B)
Mains presence (green), DC good (green), Thermal shut down (red), Overvoltage (red)
Built in fan. Horizontal front to back with variable fan speed
IEC 68-2-27, MIL-STD-810E, 20G, Telecordia GR-63-CORE, GR-487-CORE
AC OK, AC High, DC OK, Temperature OK. For the three signals: PNP open collector
(0V signal related to +out), when GOOD: 10V/5mA, Output current reading, missing module
Controls
Dimensions
Weight
Distributed Power
Telecom Access Nodes
Satellite Hubs
Broadband Switchers
XDSL Access Networks
Specifications listed assume 25C Ambient Operating Temperature and Full Load Operation unlesss otherwise specfified. This product is qualified for use in OEM equipment and is not appropriate for stand-alone operatiuon. The information contained
within this specification is believed to be true and correct at the time of publication, however, Cherokee International accepts no responsiblity for consequences arising from printing errors or inaccuracies. The information and specifications contained
herein are subject to change without notice.
Cherokee International (North America)
P: (714) 544-6665
F: (714) 838-4742
cherokeepwr.com
OUTLINE DRAWING
Pin No.
A1-A7
A8
A9-A15
A16
A17
A18
A19
A20-A22
A23-A24
A25-A26
A27-A28
A29-A30
A31-A32
Function
OUT - [-54V]
Do not connect
OUT + [+0V]
DC OK
Do not connect
Do not connect
Missing module
REMOVED
LINE
REMOVED
NEUTRAL
REMOVED
PE
Pin No.
B1-B7
B8
B9-B15
B16
B17
B18
B19
B20-B22
B23-B24
B25-B26
B27-B28
B29-B30
B31-B32
Function
OUT - [-54V]
Do not connect
OUT + [+0V]
Programming
AC OK
Termperature OK
Remote ON/OFF
REMOVED
LINE
REMOVED
NEUTRAL
REMOVED
PE
Pin No.
C1-C7
C8
C9-C15
C16
C17
C18
C19
C20-C22
C23-C24
C25-C26
C27-C28
C29-C30
C31-C32
Function
OUT - [-54V]
Do not connect
OUT + {+0V]
Current monitoring
Sharing
AC High
0V signal
REMOVED
LINE
REMOVED
NEUTRAL
REMOVED
PE
P: (714) 544-6665
F: (714) 838-4742
-1A
Revision
RoHS:
Blank = Non-Compliant
Y = 5 of 6 Compliant
Z = 6 of 6 Compliant
N: Negative Output Polarity
T: Telecom/Rectifier
Output Voltage (40~57 VDC)
Output Power (1500W)
CAR Series Power Supply
Examples:
CAR1548TN-1A = RoHS Non-Compliant
CAR1548TNY-1A = RoHS 5 of 6 Compliant
CAR1548TNZ-1A = RoHS 6 of 6 Compliant
cherokeepwr.com