IRSplit
User guide
07/10-01 PC
Content
2. Installation
3. Fundamental concepts
3.3 Download
10
10
11
16
17
18
User guide
IRSplit
1. Hardware
and Software
requirements
Mouse.
2. Installation
3. Fundamental
concepts
The IRSplit software allows the user to create a project containing all the necessary commands
for the management of the air conditioning system splitters. Subsequently, the commands are
downloaded to the device. The air conditioning system is thus integrated in the SCS system, and
can be managed using control devices such as Touch Screen.
The importing of the commands is performed through acquisition from the splitter remote control.
This procedure is non necessary if the splitter model is already listed in the software database.
Touch Screen
Database
IR Emitter
3456
IR Emitter
3456
Splitter
For the purpose of convenience the term commands in this manual will always refer to a group
of commands, because all the information that the remote control sends to the splitter will be
acquired.
For example, if we send a command to set the temperature to 17 C, in reality the remote control
will also, at the same time, send the full set of parameters for the operating mode (air conditioning,
de-humidifier, ventilation, etc.), fan-coil speed, swing, etc.
It is also possible to create custom databases, saving the controls acquired by the splitter remote
controls not included in the default database software (see the Creating a custom database
section).
User guide
IRSplit
Configuration Download.
File menu
New
Create a new project.
Open
Open an existing configuration file or a database.
Save
Save the current project.
Save as
Save the current project prompting the user to enter a file name.
Exit
Exit the software.
Tools menu
Download
Download the commands to the device.
Firmware Update
Update the device firmware.
Device Info Request
Display technical information.
Language menu
Language
Select the application language.
? menu
About
Display of some IRSplit software information.
Supported versions
It displays the list of all the device firmware versions compatible with the IRSplit software.
If a project is created and then saved as a file, no connection to the device is necessary.
User guide
IRSplit
3.3 Download
It allows the user to send the project commands to the device.
Procedure:
Connect the device to a PC as shown in the corresponding section.
From the Tools Pull-down menu select Download.
Click Exit.
User guide
IRSplit
4. Base project
configuration
Error area
10
11
User guide
IRSplit
Move the remote control near the splitter, pointing it towards the IR receiver.
Slow flashing
Quick flashing
Left LED
Right LED
IR receiver zone
Click Next.
Press the remote control key corresponding to the command to be acquired (e.g. temperature
between 21 C and 22 C).
12
The same command must now be acquired again to confirm the action.
Repeat the previous operation ensuring that the remote control is brought back to the previous
condition (21 C).
13
User guide
IRSplit
Click Finish: the command is imported in the project and is displayed in the commands area.
If the device is connected to the splitter through a cable, the command can now be tested by
clicking the appropriate key.
14
If the saving procedure has been performed correctly, the command will be executed.
It is now possible to acquire other commands, or select the commands to be downloaded to the
device.
Command ID number
To download the commands to the device, perform the download procedure as shown in the
appropriate section.
15
User guide
IRSplit
Database Area
Now the user can select the commands to download to the device.
As already discussed, these are not individual commands, but sequences of parameters.
Example:
ID269: on, warm, 17 C, automatic fan-coil speed, etc.
To download the commands to the device perform the connection procedure, followed by the
download procedure, as shown in the appropriate sections.
16
5. Advanced
project
configuration
Using this configuration, it is possible to create a project containing all the commands of a certain
splitter. In this way the splitter is managed by the Touch Screen as if using its remote control.
Select the brand/model.
The area on the right will show the models features, and all the commands that will be downloaded
to the device.
Available commands
Model features
To download the commands to the device perform the connection procedure, followed by the
download procedure, as shown in the appropriate sections.
17
User guide
IRSplit
6. Creating
a custom
database
The database in the software can be customised by adding the commands of splitters acquired by
the user.
Select File/Open/Database.
Select Brand in the Personal folder.
Use the right key to add the brand.
Enter a description, and click OK.
Select the created brand and use the right key to add the model. Enter a description and press OK.
18
Follow the procedure shown in the Acquiring commands from a remote control section.
When the procedure is completed, the following screen appears:
19
User guide
IRSplit
The model previously saved is now listed in the database, and can be used in the same way as those
already listed by default.
20
BTicino SpA
Via Messina, 38
20154 Milano - Italy
www.bticino.com
BTicino SpA reserves at any time the right to modify the contents of this booklet and to communicate, in any form and modality,
the changes brought to the same.