Vous êtes sur la page 1sur 75

Fiber Optic Cables

2014

fiber optic cables fibrain


5

16

29

Basic Information

Designation
FOC Parameters
Low Loss Fibers
SM/MM Bendsafe Fibers
Fiber and Cables Information
Fiber Identification

Page 5

Page 5
Page 6
Page 7
Page 8
Page 9
Page 10

DATACOM

Page 16

FTTH

Page 29

Buffer BFR
Simplex SMX
Duplex ZIP
LDC
LBR
DC PRIM
DC DRIM
EXO CU
EXO C0
EXO CI
BDC SSA
BDC MSA

VC-D20
VC-D30
VC-DCS
VC-DCY
DC PRIM
EAC-RAs
EAC-RAd
DAC-BURRY
AERO DF03

Page 16
Page 17
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Page 27
Page 28

Page 31
Page 32
Page 33
Page 34
Page 35
Page 36
Page 37
Page 38
Page 39

content

fiber optic cables fibrain


41

51

59

73

MICRODUCT

Page 40

Telecom Duct

Page 51

Telecom Aerial

Page 59

Special Cables

Page 72

MK-AX2
MK-DX2/25/3
MK-LX4
MK-LXS6/7/8
MK-LX6
MK-LX7
MK-LX8
MK-LX9
MK-LX11

BDC SI
BDC MSA
BDC C0
BDC CI
DDC SI
DDC C0
DDC CI

Aero-DF01
Aero-AS02 2.0mm
Aero-AS03 2.0mm
Aero-AS03 2.5mm
Aero-AS04 2.0mm
Aero-AS04 2.5mm
Aero-AS06 2.0mm
Aero-AS06 2.5mm
Aero-AS09 2.0mm
Aero-AS09 2.5mm
Aero-AS12 2.5mm
Aero -AS14 2.5mm

FTTA-DAC
BDC-CIP

Page 42
Page 43
Page 44
Page 45
Page 46
Page 47
Page 48
Page 49
Page 50

Page 52
Page 53
Page 54
Page 55
Page 56
Page 57
Page 58

Page 60
Page 61
Page 62
Page 63
Page 64
Page 65
Page 66
Page 67
Page 68
Page 69
Page 70
Page 71

Page 73
Page 74

content

Basic
Information

Mechanical Features

symbols
Rodent
Protection Basic

Rodent
Protection High

Rodent
Protection
Extreme

Flexible

Last mile
connection outdore

Aerial

Hi-crush

Direct buried

Duct

Microduct
Generation 1

ETR

Industrial

Mining

Military

Oil resistance

Ship
and oshore

Robotic

Windfarms

Datacenter

Datacom

Telecom

FTTH

FTTA

Semi-tight

Easy-strip

LSOH

Compact design

Flexible

Multiber
connectors
termination

Easy to terminate

Last mile
connection indore

Bendsafe

Low Friction

Hybrid FO
+ Power

Blowing
installation

Design features

Branch of business

Optimal
diameter

FOC parameters
single-mode fiber types

Fiber types and applications

Maximum attenuation for uncabled fibers


IL [dB/km]

Fiber type
ITU-IT

Tight 900 m fiber

Possibility to remove the 900 m coat at the


distance of 1-2 cm

1310nm

1383nm

1410nm

1450nm

1490nm

1550nm

1625nm

Standard single mode telecomuG.652D nication fiber with zero water-pick


attenuation

0.34

0.31

0.24

0.20

0.23

Premium single mode fiber low loss


G.652D LL with zero water-pick and lower
attenuation in whole bandwidth

0.32

0.31

0.21

0.18

0.20

Long distance single mode fiber


with non-zero dispersion shifted
G.655
(NZDSF) for CWDM and DWDM
A,B,C,D
system 10G
and futre 40G or 100G

0.40

0.32

0.26

0.19

0.21

Long distance single mode fiber


G.656 with non-zero dispersion shifted
A,B,C,D (NZDSF) for CWDM and DWDM
system 10G and futre 40G or 100G

0.40

0.32

0.26

0.19

0.21

Available bend radius

Bend insensitive fiber fully


G.657A1 compatible with G.652D standard,
bend radius 10-15mm

0.35

0.35

0.24

0.20

0.23

BEND RADIUS

Bend insensitive fiber fully


G.652A2 compatible with G.652D standard,
bend radius 7.5mm

0.35

0.35

0.24

0.20

0.23

Bend insensitive fiber fully


G.652B3 (A3) compatible with G.652D standard,
bend radius 5mm

0.35

0.35

0.24

0.20

0.23

Bend insensitive fiber, non-compatible with G.652D standard, for


G.652B3 Plus
connectorization application, bend
radius 2.5mm

0.35

0.35

0.24

0.21

0.23

Semi- tight 900 m fiber

Possibility to remove the 900 m coat at the


distance of 10-20 cm

Easy strip 900 m fiber

Possibility to remove the 900 m coat at the


distance of 100-150 cm.

7.5

BEND RADIUS

10

mm

mm

BEND RADIUS

BEND RADIUS

15

mm

30

mm

multimode fiber types


BEND RADIUS

Overfilled
modal
bandwidth
[MHz/km]

Fiber
type
ITU-IT

Fiber Capacity
[m]

Attenuation
[dB/km]

Bending loss
2 turns [dB]

Bending loss
10 turns [dB]

Radius = 7.5mm Radius = 15mm

Radius = 30mm

850
nm

40GBASE1300
SR4/
1GBase-SR 10GBase-SR
nm
100GBASESR10

850
nm

1300
nm

62.5/125
OM1

160

500

275

2.6

0.5

50/125
OM2 Bend
Insensitive

500

500

600

83

2.3

0.5

0.2

0.5

0.1

0.3

50/125
OM3 Bend
Insensitive

1500

500

1000

300

140*

2.4

0.5

0.2

0.5

0.1

0.3

50/125
OM4 Bend
Insensitive

3500

500

1100

550

170*

2.4

0.6

0.2

0.5

0.1

0.3

850
nm

1300
nm

850
nm

1300
nm

850 nm 1300 nm
0.5

* Maximum cabled fibre attenuation 3.0 dB/km at 850 nm, maximum total connector loss of 1.0 dB and VCSELs maximum RMS spectral width of 0.29
nm (according to IEEE 10GbE model: http://grouper.ieee.org/groups/802/3/ae/public/adhoc/serial_pmd/documents/10GEPBud3_1_16a.xls).

Bending loss
G.652D

Mandrel R=30mm 100turns


1550/1625nm 0.03dB

Mandrel R=25mm 1310/1550nm 100 turns


0.03dB

Mandrel R=15mm 10 turn


1550nm 0.25dB 1625nm 1.0dB

G.652D LL

Mandrel R=30mm 100turns


1550/1625nm 0.03dB

Mandrel R=25mm 1310/1550nm 100 turns


0.03dB

Mandrel R=15mm 10 turn


1550 0.25dB 1625nm1.0dB

G.655 A.B.C.D

Mandrel R=30mm 100turns


1550/1625nm 0.05dB

Mandrel R=15mm 1550/1625nm 1 turn


0.5dB

G.656 A.B.C.D

Mandrel R=30mm 100turns


1550/1625nm 0.05dB

Mandrel R=15mm 1550/1625nm 1 turn


0.5dB

G.657A1

Mandrel R=15mm 10turns


1550nm0.20dB. 1625nm 0.50dB

Mandrel R=10mm 1 turns 1550nm


0.50dB. 1625nm 1.50dB

G.652A2

Mandrel R=15mm 10turns


1550nm0.03dB. 1625nm 0.10dB

Mandrel R=10mm 1 turns 1550nm0.10dB.


1625nm 0.2dB;

Mandrel R=7.5mm 1 turns


1550nm 0.50dB. 1625nm 1.0dB

G.652B3 (A3)

Mandrel R=10mm 1turns


1550nm0.03dB. 1625nm 0.10dB

Mandrel R=7.5mm 1 turns 1550nm


0.05dB. 1625nm 0.15dB

Mandrel R=5mm 1 turns


1550nm0.10dB. 1625nm 0.30dB

G.652B3 Plus

Mandrel R=5mm 1 turns


1550nm0.10dB. 1625nm 0.20dB

Mandrel R=2.5mm 1 turns 1550nm


0.20dB. 1625nm 0.30dB

40

mm

BEND RADIUS

60

mm

low loss

Low Loss Fibers

fibers

At present, low less and pure quartz optic fibers with max. 0,17dB/km attenuation for 1550 nm wavelength and max. 0,31dB/km for 1310 nm wavelength are ready
for use . Low loss and pure quartz optic fibers have at least 0,02dB/km lower spectral attenuation in comparison to the standard ones G.652D. In such fibers, the
retention of flat spectral characteristics within the transmission windows provide the possibility of achieving substantially smaller deviations of attenuation:
1310 nm (+ 20nm / -35 nm) wavelength max. deviation is 0,03 dB/km
1550 nm ( + 25 nm / -25 nm) wavelength max. deviation is 0, 02 dB km with the retention of 1625 nm attenuation 0,20 dB/ km.
The chromatic dispersion complies with ITU-T G.652 and the polarizing at the level of 0,04 ps/km of these fibers provides the possibility of using such fibers
in high- speed systems e.g. transmission of 10 GBit/s or even higher. Low loss fibers which are obtained in the pure quartz technology can work properly in telecommunication networks at the distance of even thousand kilometers far, which significantly limits the number of necessary amplifiers and repiters in a fiber optic
connection.

0.40
0.30

G.657.A1

G.652.D LL

G.652.D

G.657.A1

G.652.D LL

G.652.D

G.657.A1

G.652.D LL

G.652.D

G.657.A1

G.652.D LL

G.652.D

G.657.A1

0.10

G.652.D LL

0.20
G.652.D

Attenuation [dB/km]

Attenuation / Wavelength

25
16

50
15

90
14

83
13

10
13

Wavelength [nm]

Optical parameters
Parameter

Value

Change in attenuation/ Non- continuity points

for 1310 nm and 1550 nm 0.05 dB


1 cable coil of 32 mm diameter (1.2) for 1550 nm wavelength < 0.03 dB

Attenuation in the macro-bend function

100 cable coils of 50mm diameter (2) for 1310 nm wavelength < 0.03 dB
100 cable coils of 60mm diameter (2.4) for 1550 nm wavelength < 0.03 dB, for 1625 nm < 0.03 dB

Zero- dispersion wavelength

1302 1322 nm

Curve gradient for zero dispersion

0.090 ps/nm2-km
for 1310 nm 9.2 0.4 m

Diameter of the mode field

for 1550 nm 10.4 0.5 m

Cut-off wavelength

< 0.04 ps/km

Max. value for the single fiber

< 0.1 ps/km

Typical value for LMC PMD fiber

< 0.02 ps/km

Thermic cycle (-60C do +85C)

0.05 dB/km

Aging in high temperatures (85 2C)

0.05 dB/km

Temperature cycle/ humidity (for - 10C to +85C; 95% RH)

0.05 dB/km

Immersion in water (23 2 C)

0.05 dB/km

Dynamic coefficient of fatigue for tension corrosion (nd)

20

SM G.652D RAL 1021

SM G657 A1, A2, A3


RAL 9010

MM 50/1025 OM2
RAL9018

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

low loss Fibers Introduction | 7

Bend radius [mm]

40

30

10

7,5

8 | SM/MM Fibers
G.652D

10

7,5

Bendsafe MM Fibers

50/125 OM4
Bend Insensitive

G.656 - A.B.C.D
G.657A1

mm

40

G.652A2
G.652B3 (A3)

0.30dB 0.20dB

G.652A1,A2

0.20dB 0.10dB

G.657B3

0.30dB 0.10dB

G.657B2,B3

30

BEND RADIUS

Max. attenuation for wavelength


1550 nm 1625nm/both [dB]

15
BEND RADIUS

0.15dB 0.05dB

SM/MM

0.10dB 0.03dB

mm

15

1.00dB 0.50dB

mm

0.20dB 0.10dB

mm

0.10dB 0.03dB

BEND RADIUS

1.50dB 0.50dB

G.655 - A.B.C.D

0.50dB 0.20dB

mm

10

0.50dB

BEND RADIUS

0.05dB

0.50dB

0.05dB

1.00dB 0.25dB

G.652D LL

0.20dB 0.50dB

50/125 OM2
50/125 OM3
Bend Insensitive Bend Insensitive

0.10dB 0.30dB

7.5

0.03dB

BEND RADIUS

Bending loss for wavelength


850nm 1300nm/both [dB]

15
0.03dB

G.652D

0.20dB 0.50dB

1.00dB 0.25dB

0.03dB

60

0.10dB 0.30dB

60

0.20dB 0.50dB

30
0.03dB

40

0.10dB 0.30dB

Bend radius [mm]

BENDSAFE FIBERS

SM/MM Fibers

Available bend radius

BEND RADIUS

mm

60

Bendsafe SM Fibers

G.652B3 Plus

FOC fiber and cables information


Post-production fiber parameters

Tight buffer vs. Loose tube

Wavelength (nm) [dB/km]

Type

1310

1550

Low Loss (LL)

0.34

0.22

Telecom

0.35

0.25

Standard

0.40

0.30

Datacom

0.40

0.40

Loose
tube

Tight buer

1-3mm
900m

900 m outer coating

Tube

Gel

Core

125 m coating

250 m coating

Stripping
Tight buer
Tight 900 m ber

Semi-tight
Semi-tight 900 m ber

Easy strip
Easy strip 900 m ber

Possibility to remove the 900 m


coat at the distance of 1-2 cm

Possibility to remove the 900 m


coat at the distance of 10-20 cm

Possibility to remove the 900 m


coat at the distance
of 100-150 cm.

FOC fiber and cables information | 9

FOC

telecom

fiber identification

Fiber colors code in loose tube cable design


Other colors available for demand
T-Telecom (according to IEC 60304)
1-12

10

11

12

Code

24

13

14

23

Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

16

21

17
20

Code
Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

natural

15

22

18

19

aqua

*In case of 24 fibers tube construction colors will be repeated and for easier identification fibers 13-24 will have rings every 25cm.

T1-TELecom (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02)


1-12

10

11

12

Code

24

13
1

Color

red

blue

white

green

violet

orange

grey

yellow

brown

pink

black

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

16

21

17
20

red

blue

white

green

violet

orange

grey

yellow

brown

pink

natural

15

22

Code
Color

14
2

23

19

18

aqua

*In case of 24 fibers tube construction colors will be repeated and for easier identification fibers 13-24 will have rings every 25cm.

T2-TELecom (according to EIA 598A)


1-12

10

11

12

Code

24

13
1

23

Color

blue

orange

green

brown

grey

white

red

yellow

yellow

violet

pink

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Color

blue

orange

green

brown

grey

white

red

natural

yellow

violet

pink

aqua

*In case of 24 fibers tube construction colors will be repeated and for easier identification fibers 13-24 will have rings every 25cm.

10 | foc fiber color codes

15

22

16

21

17
20

Code

14
2

19

18

FOC

telecom

fiber in loose tube color codes

Loose tube colors code in loose tube cable design


Other colors available for demand
t-telecom - Loose tube in cable (according to iec60304):
Tube

10

11

12

12

Code
Color

11

10

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

**For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
***In case of lower fiber count some tubes can be replaced by fillers.

t1-telecom - Loose tube in cable (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02)
Tube

10

11

12

12

Code
Color

11

10

red

blue

white

green

violet

orange

grey

yellow

brown

pink

black

aqua

**For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
***In case of lower fiber count some tubes can be replaced by fillers.

t2-telecom - Loose tube in cable (according to EIA 598A)


Tube

10

11

12

12

Code
Color

11

10

blue

orange

green

brown

grey

white

red

black

yellow

violet

pink

aqua

**For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
***In case of lower fiber count some tubes can be replaced by fillers.

t3-telecom - Loose tube in cable according to IEC 60304)


Tube

10

11

12

13

14

15

Code
Color

15

14

13

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

luminous
red

patina
green

signal
blue

**For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
***In case of lower fiber count some tubes can be replaced by fillers.

12

5
6

11
10

E-telecom - Loose tube in cable (according to EIA 598A)


Tube

10

11

12

red

green

white

white

white

white

white

white

white

white

white

white

Code
Color

**For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
***In case of lower fiber count some tubes can be replaced by fillers.

FOC fiber color codes | 11

FOC

datacom

fiber color codes

Fiber, buffer and tubes colors codes for Datacom cables range
Other colors available for demand
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304)
Fiber in buffer
1-12

10

11

12

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

natural orange

pink

Color*

red

green

blue

yellow

white

grey

brown

violet

brown

dark
green

orange

pink

10

11

12

Fibre
Buffer
250/900/600m

Fibre
Buffer
250m

600/900m

* - buffer with black ring for identification fibers 13-24

Fibers in tubes
1-12

13

24

Code

23

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

red

green

blue

yellow

white

grey

brown

violet

aqua

dark
green

orange

pink

14
2

15

22

16

21

17
20

18

19

Code
Color

*In case of 24 fibers tube construction colors will be repeated and for easier identification fibers 13-24 will have rings every 25cm.

Loose tubes in cables


Tube

10

11

12

Code
Color

12

11

10

red

green

blue

white

violet

orange

grey

yellow

brown

**For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
***In case of lower fiber count some tubes can be replaced by fillers.

12 | foc fiber color codes

pink

black

aqua

FOC

datacom

fiber color codes

Fiber and buffer colors code for datacom cables range


Other colors available for demand
D1-DATACOM (according to IEC 60304 ; TIA/EIA 598-A ; TIA/EIA 598-C /Data Center cables)
Fiber in buffer
1-12

10

11

12

Color

blue

orange

green

brown

grey

white

red

natural

yellow

violet

pink

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Color

blue

orange

green

brown

grey

white

red

natural

yellow

violet

pink

aqua

Color*

blue

orange

green

brown

grey

white

red

dark
green

yellow

violet

pink

aqua

10

11

12

Fibre
Buffer
250/900/600m

Fibre
Code
250m

600/900m

* - buffer with black ring for identification fibers 13-24

Fibers in tubes
1-12

24

13
1

23

Code

14
2

15

22

Color

blue

13-24

orange

green

brown

grey

white

red

yellow

yellow

violet

pink

aqua

13

14

15

16

17

18

19

20

21

22

23

24

blue

orange

green

brown

grey

white

red

natural

yellow

violet

pink

aqua

16

21

17
20

19

18

Code
Color

*In case of 24 fibers tube construction colors will be repeated and for easier identification fibers 13-24 will have rings every 25cm.

Loose tubes in cables


Tube

10

11

12

12

2
3

11

Code
10

Color

red

green

blue

white

violet

orange

grey

yellow

brown

**For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
***In case of lower fiber count some tubes can be replaced by fillers.

pink

black

aqua

4
9

5
8

FOC fiber color codes | 13

FOC

ftth

fiber color codes

Fiber and buffer colors code for FTTH cables range


Other colors available for demand
F-FTTH (according to DIN VDE 0888 & IEC 60304)
1-12

10

11

12

Color

red

blue

green

yellow

violet

white

orange

grey

brown

black

aqua

pink

Color

red

blue

green

yellow

violet

white

orange

grey

brown

black

aqua

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Fibre
Buffer
250m

600/900m

Fibre

24

13
1

23

Code
Color
250m

Color*

600/900m

14
2

15

22

red
red

blue
blue

green
green

yellow
yellow

* - buffer with black ring for identification fibers 13-24

14 | foc fiber color codes

violet
violet

white
white

orange
orange

grey
grey

brown
brown

black
dark
green

aqua
aqua

pink
pink

16

21

17
20

19

18

FIBRAIN
COATINGS

Industrial

Oil resistance

Mining

Ship and oshore

Military

Windfarms

Robotic

Datacenter

Telecom

Coatings physical properties


PE polyethylene

LSOH

PVC polyvinyl chloride

PUR polyurethane

PA polyamide

NBR nitrile rubber

Mechanical resistance

Mechanical resistance

Mechanical resistance

Mechanical resistance

Mechanical resistance

Mechanical resistance

Temperature resistance

Temperature resistance

Temperature resistance

Temperature resistance

Temperature resistance

Temperature resistance

Chemical resistance

Chemical resistance

Chemical resistance

Chemical resistance

Chemical resistance

Chemical resistance

datacom

DATACOM BFR 0.6 - 0.9 mm

Buffer bFR
Cable structure

1. Outer Tight Buffer Tube


600/900m (LSOH)
2. Colored Coating on Fiber 250m
3. Optical Fiber with cladding
125m

1
3

TRUE
COLORS

Flexible

Easy to terminate

Semi-tight

Easy-strip

Bendsafe

Configuration

bfr
Fibers

Applications

Max. installation
tension [N]

1F

0.6

0.7

1F

0.9

0.75

Stripping - length in
one piece [cm]

Stripping

TB05/TB10

Connectivity

Pigtails assembly

Datacom and telecom terminal connectors

50 / 100

Available outer jacket colors

Yellow

Features

Orange

Aqua

Green

Blue

Violet

White

Version

Fiber qnt

nominal
5% [mm]

Max. tensile load


5% [N]

Crush [N]/10cm

1F

0,6

0,7

1F

0,9

0,75

Tight buffer, semi tight and easy strip options

True color fiber and coating for easier identification

Easy to strip

LSOH materials

Operating temperature
+100

10

11

12

Fibre

+5C
-10C
-20C

Buffer
Color

250/600/900m

red

green

blue

yellow

white

16 | datacom buffer bfr cables

grey

brown

violet

aqua

black

orange

pink

-100

OPERATION

1-12

+50C

+40C
INSTALLATION

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304)

temperature [C]

+60C

Color codes

TRANSPORT

Version

nominal
5% [mm]

Nominal
weight
5%
[kg/km]

datacom

Simplex SMX 1.2 - 2.8 mm

simplex smx cable


Cable structure

1. LSOH Outer Sheath


2. Aramid Yarns
3. Central Tight Buffer Tube 900m
with colored fiber 250m

2
3

TRUE
COLORS

Flexible

Easy to terminate

Semi-tight

Easy-strip

Bendsafe

Configuration

smx
Version

Fiber qnt

nominal
5% [mm]

Max. installation
tension 5% [N]

Crush
[N/10cm]

1F

1,2

35

200

1F

1,6

70

500

1F

1,8

100

500

1F

2,8

350

1000

Applications

Cables distribution system

For Patchcords and Pigtails

Terminals connection

Features

Sheath colors

Standard

Yellow

Orange

Aqua

Green

Blue

Violet

LSOH with low coefficient of friction (nom. 0,3)

Aramid yarns

Central tight buffer 900m tube

250m Colored fiber

Low-radius bending resistance SM

White

30mm

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304)


1-12

10

11

12

Fibre

bend radius [mm]

Color codes

G.652D

15mm

G.657A1

7,5mm

G.657A2

Buffer
yellow

white

grey

brown

violet

aqua

black

orange

pink

Operating temperature
+100
+70C
+55C

-5C

TRANSPORT

blue

OPERATION

green

INSTALLATION

red

temperature [C]

Color

250/600/900m

-20C
-40C

-100

datacom simplex smx cables | 17

DATACOM
CABLES

TRUE
COLORS

Available colors of tubes and cables

orange

green

grey

red

violet

yellow

black

brown

pink

aqua

datacom

Duplex Zip Cables 1.2 - 2.8mm

duplex zip cables


Cable structure
1. LSOH Outer Sheath
2. Aramid Yarns
3. Central Tight Buffer Tube
900m with colored
fibers 250m

1
2

TRUE
COLORS

LSOH

Easy to terminate

Bendsafe

Semi-tight

Easy-strip

Configuration
Applications

ZIP
Version

Fiber qnt

Dimensions
nominal
5% [mm]

Max. installation
tension
5% [N]

Crush
[N/10cm]

2F

1,2 x 2,7

70

200

2F

1,6 x 3,5

140

500

2F

1,8 x 3,9

200

500

2F

2,8 x 5,9

700

1000

Sheath colors

Standard

Distribution systems cable

For Patchcords and Pigtails

Terminals connection

Structure and composition

LSOH with low coefficient of friction

Aramid yarns

250m Colored fibers

Low-radius bending resistance SM


Yellow

Orange

Aqua

Green

15mm

G.657A1

7,5mm

G.657A2

Operating temperature
+100
+70C

-5C

TRANSPORT

+50C
OPERATION

White

G.652D

INSTALLATION

Violet

temperature [C]

Blue

bend radius [mm]

30mm

-20C
-40C

-100

datacom DUPLEX ZIP CABLES | 19

datacom

LDC

LDC
Cable structure

1. Outer sheath LSOH UV Stabilized


2. Tight Tubes 900m (LSOH)
with colored fibers 250 m
3. Aramid Yarns as tensile strength

TRUE
COLORS

LSOH

Bendsafe

Easy to terminate

Semi-tight

Easy-strip

Datacenter

Construction

LDC
Tight
buffers
[pcs]

5%
[mm]

Nominal
weight LSOH
5% [kg/km]

2F

4,5

21

4F

5,0

26

6F

5,5

30

8F

6,0

35

10F

10

6,5

40

12F

12

6,5

45

16F

16

7,0

50

24F

24

8,0

65

installation

operation

1000

Applications

Crush
[N/10cm]

280
500

1200

340

1500

400

Cable for indoor/outdoor installation

For distribution networks in multifamily buildings

FTTD Connections

Distribution systems

Fully dielectric

LAN and FTTX network

ODF connection

Datacenter distribution

Features

Sheath colors

Compact dimensions

Lightweight

Flexible

Fibre

Easy to strip

Buffer

Totally dielectric

Reduced diameter

Direct connectorization

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304)


1

10

11

12

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Fibre

Operating temperature

Code

+100
red

green

blue

yellow

white

grey

brown

violet

aqua

natural orange

pink

Color*

red

green

blue

yellow

white

grey

brown

violet

brown

dark
green

pink

250m

600/900m

* - buffer with black ring for identification fibers 13-24

orange

+70C

temperature [C]

Color

+50C

-5C
-20C
-40C

-100

20 | datacom LDC

TRANSPORT

250/600/900m

INSTALLATION

1-12

OPERATION

Version

Max. tensile load [N]

datacom

LBR

LBR
Cable structure
1. Outer sheath LSOH
UV Stabilized
2. Subcables 1,8mm
with Tight Tubes
900m (LSOH)
with colored fibers
250m

1
2

3. Aramid Yarns as
tensile strength
4. Central FRP strength
member
5. Ripcord

1
2

5
TRUE
COLORS

LSOH

Easy to terminate

Bendsafe

Semi-tight

Easy-strip

Datacenter

Construction
Applications

LBR
Fiber qnt

5%
[mm]

Nominal weight
LSOH 5%
[kg/km]

installation

operation

Max. tensile load [N]

Crush
[N/10cm]

Cable for indoor/outdoor installation

For distribution networks in multifamily buildings

FTTD Connections

Distribution systems

4F

6,6

48

500

170

6F

7,4

63

650

210

Fully dielectric

LAN and FTTX network

ODF connection

Datacenter distribution

8F

8,4

85

750

250

12F

12

10,8

131

1000

330

16F

16

10,5

119

1200

400

18F

18

11,0

131

1500

500

24F

24

13,0

179

2000

660

2000

Features

Standard jacket colors:

LSOH Light Grey


RAL7037

Fully dielectric cable

Aramid yarns as tensile elements

UV Resistant and flame retardant outer sheath


LSOH

Operating temperature
+100

temperatura [C]

Outer jacket color options:

SM G.652D
RAL 1021

SM G657A1, A2, A3
RAL 9010

MM 50/125 OM2
RAL9018

MM 50/125 OM3
RAL6027

MM 50/125 OM4
RAL4003

+60C
+50C
+40C

-5C

OPERTATION

LSOH Grey RAL7022

Simplex sub cable up to 24

INSTALATION

PE Black RAL9005

TRANSPORT

Version

-25C

-100

datacom LBR | 21

datacom

DC-PRIM

DC PRIM
Cable structure

1. Outer Jacket LSOH


2. High modulus Aramid Strength Yarns
3. Optical Fibers 250m

2
3

TRUE
COLORS

LSOH

Bendsafe

Easy to terminate

Semi-tight

Easy-strip

Datacenter

Construction
Applications

DC-PRIM
No. of Fibers

12

24

Outer diameter [mm]

3,0

4,5

Tensile load perm/inst. [N]

350

450

20

45 (depends on fiber type)

60 (depends on fiber type)

Weight [kg/km]
Min. bend radius [mm]

Optical cable with Aramid yarns reinforcement

For customer connection, fully dielectric cable

MTP/MPO termination cable

LAN and FTTX networks

Distribution network

Inside house OLT connection

Data Center connections cable

Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304)
1

10

11

Fibre
Buffer
Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Aramid strength element,

Optical fibers 250m (12-24)

Outer jacket LSOH

Operating temperature

Fibre

+100

Code
green

blue

yellow

white

grey

brown

violet

aqua

natural orange

pink

Color*

red

green

blue

yellow

white

grey

brown

violet

brown

dark
green

pink

600/900m

* - buffer with black ring for identification fibers 13-24

orange

+55C

-5C
-10C
-25C

-100

22 | datacom DC-PRIM

TRANSPORT

red

250m

temperature [C]

+70C

Color

OPERTATION

250/600/900m

Features

12

INSTALATION

1-12

datacom

DC-DRIM

DC-DRIM

Cable structure
1. Outer Jacket LSOH
2. High modulus Aramid Strength Yarns
3. Inner Jacket LSOH
4. High modulus Aramid Strength Yarns
5. Optical Fibers 250m

1
2

1
2
3
5

TRUE
COLORS

LSOH

Bendsafe

Easy to terminate

Semi-tight

Easy-strip

Datacenter

Construction
Applications

DC-DRIM
No. of Fibers

12

24

Outer diameter [mm]

4,5

6,0

Tensile load perm/inst. [N]

850

1000

Weight [kg/km]

10

25

45 (depends on fiber type)

60 (depends on fiber type)

Min. bend radius [mm]

Optical cable with Aramid yarns reinforcement

For customer connection, fully dielectric cable

MTP/MPO termination cable

LAN and FTTX networks

Distribution network

Inside house OLT connection

Data Center connections cable

Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304)
1

10

11

Fibre
Buffer
Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Fibre

Aramid strength element in two layers

Optical fibers 250m (12-24)

Double jacket LSOH

Operating temperature
+100

Code
green

blue

yellow

white

grey

brown

violet

aqua

natural orange

pink

Color*

red

green

blue

yellow

white

grey

brown

violet

brown

dark
green

pink

600/900m

* - buffer with black ring for identification fibers 13-24

orange

+55C

-5C
-10C

TRANSPORT

red

250m

temperature [C]

+70C

Color

OPERTATION

250/600/900m

Features

12

INSTALATION

1-12

-25C

-100

datacom DC-DRIM | 23

datacom

EXO-CU Cables Loose Tube

exo cU cables
Cable structure

1. Outer Jacket PE or LSOH


2. Glass Fiber Yarns
3. Central Loose Tube (PBT)
with colored fibers in filling gel
4. Ripcord

ETR

Datacom

Compact design

Rodent
Protection Basic

LSOH

LSOH Jacket

Construction
Applications

Exo-CU
Fiber qnt

Nominal
weight PE
5% [kg/km]

Max. tensile
load [N]

Nominal weight
LSOH 5%
[kg/km]

1T x 2F

6.4

36

47

1T x 4F

6.8

37

48

1T x 6F

6.8

37

51

1T x 8F

6.8

38

51

1T x 12F

12

6.8

38

52

1T x 24F

24

7.1

45

62

installation

Crush
[N/10cm]

operation

Fully dielectric cable

Rodent protection cable

LAN and FTTX networks

Distribution network

ODF connections

1100

(e=0,33%)

300

1600

700

(e=0,5%)

Features

Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers in tube
1-12

10

11

12

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Code

Fiberglass strength element

Optical fibers

Loose tube filled with jelly

Loose tube (PBT)

Fiberglass yarns as tensile elements

PE or LSOH Outer Sheath

Operating temperature
+100

Code
blue

yellow

white

grey

brown

violet

dark
green

aqua

orange

*In case of 24 fibers tube construction colors will be repeated and for easier identification fibers 13-24 will have rings every 25cm.

Fiber identification

Sheath colors

+70C

pink

+55C

-5C

Standard
24

13
1

23

-50C

14
2

15

22

16

21

17
20

PE Black RAL9005

LSOH Grey RAL7022

LSOH Light Grey RAL7037

Optional

SM G.652D RAL 1021

SM G657 A1, A2, A3


RAL 9010

MM 50/1025 OM2
RAL9018

24 | datacom exo-CU cables

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

19

18

-100

TRANSPORT

green

OPERATION

red

temperature [C]

Color

INSTALLATION

Version

5%
[mm]

datacom

EXO-C0 Cables Loose Tube

exo c0 cables
Cable structure

1. Outer Jacket PE or LSOH


2. Glass Fiber Yarns
3. Central Loose Tube (PBT)
with colored fibers in filling gel
4. Ripcord

ETR

Datacom

Compact design

Rodent
Protection Basic

LSOH

LSOH Jacket

Construction

Exo C0
Fiber qnt

5%
[mm]

1T x 2F

6.8

37

52

1T x 4F

7,2

38

53

1Tx 6F

7.2

42

57

1T x 8F

7,2

42

58

1T x 12F

12

7.2

42

58

1T x 16F

16

7.4

45

62

1T x 24F

24

7.4

46

62

Applications

Max. tensile
load [N]

Nominal weight
LSOH 5%
[kg/km]

installation

Crush
[N/10cm]

operation

1300

500

Fully dielectric cable

Rodent protection cable

LAN and FTTX networks

Distribution network

ODF connections

1500

Features

Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers in tube
1-12

10

11

12

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Code

Fiberglass strength element

Optical fibers

Loose tube filled with jelly

Loose tube (PBT)

Fiberglass yarns as tensile elements

PE or LSOH Outer Sheath

Operating temperature
+100

Code
blue

yellow

white

grey

brown

violet

dark
green

aqua

+70C

orange

pink

*In case of 24 fibers tube construction colors will be repeated and for easier identification fibers 13-24 will have rings every 25cm.

Fiber identification

Sheath colors

Standard
24
23

14
2

15

22

16

21

LSOH Grey RAL7022

-100

17
20

PE Black RAL9005

-5C

-50C

13
1

+55C

TRANSPORT

green

OPERATION

red

temperature [C]

Color

INSTALLATION

Version

Nominal
weight PE 5%
[kg/km]

19

18

LSOH Light Grey RAL7037

Optional

SM G.652D RAL 1021

SM G657 A1, A2, A3


RAL 9010

MM 50/1025 OM2
RAL9018

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

datacom exo-c0 Cables | 25

datacom

EXO CI Cables Loose Tube


EXO-CI

exo cI cables
exo-cI
Cable structure

1. Outer Jacket PE or LSOH


2. Glass Fiber Yarns
3. Central Loose Tube (PBT)
with colored fibers in filling gel
4. Ripcord

ETR

Datacom

Compact design

Rodent
Protection Basic

LSOH

LSOH Jacket

Construction

Exo-CI
Exo CI
Version

Fiber qnt

5%
[mm]

Nominal
weight
weight
PE PE
5%
5%
[kg/km]
[kg/km]

1T x 2F

7.1

41

52

1T x 4F

7.4

41

53

1Tx 6F

7.4

42

57

1T x 8F

7.4

44

58

1T x 12F

12

7.4

46

58

1T x 16F

16

7.7

49

62

1T x 24F

24

7.7

49

62

Applications

Max. tensile
load [N]

Nominal weight
LSOH
LSOH
5%
5%
[kg/
[kg/km]
km]

instalshort
lation
term

Crush
[N/10cm]

operalong
term
tion

1800

1000

Fully dielectric cable

Rodent protection cable

LAN and FTTX networks

Distribution network

ODF connections

1500

Features

Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers in tube
1-12

10

11

12

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Fiberglass strength element

Optical fibers

Loose tube filled with jelly

Loose tube (PBT)

Fiberglass yarns as tensile elements

PE or LSOH Outer Sheath

Code

Operating temperature
+100

Code
yellow

white

grey

brown

violet

dark
green

aqua

+70C

orange

pink

*In case of 24 fibers tube construction colors will be repeated and for easier identification fibers 13-24 will have rings every 25cm.

Fiber identification

Sheath colors

24

13
1

23

-100

14
2

15

22

16

21

17
20

LSOH Grey RAL7022

PE Black RAL9005

LSOH Light Grey RAL7037

LSOH Grey RAL7022

SM G657 A1, A2, A3


RAL 9010

MM 50/1025 OM2
RAL9018

26 | datacom exo-CI CABLES

19

LSOH Light Grey RAL7037

Optional

SM G.652D RAL 1021

-5C

-50C

Standard

PE Black RAL9005

+55C

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

18

TRANSPORT

blue

OPERATION

green

INSTALLATION

red

temperature [C]

Color

datacom

DATACOM BDC-SSA

bdc-SSA
Cable structure

5. Central Strength
Member (FRP)
6. Loose Tubes (PBT)
with colored fibers
in filling gel
7. Fillers
8. Ripcord

1. PE Sheath
2. Water-blocking
Fiberglass Yarns
3. Water blocking
Yarns
4. Estrofol Tape

2
4

3
6

7
8

ETR

Datacom

Rodent
Protection Basic

LSOH

Compact design

Datacenter

Configuration

BDC SSA

5%
[mm]

Active
tubes

10%
[kg/km]

installation

operation

1T x 4F

7,5

32

1520

490

1T x 6F

7,5

33

1520

490

1T x 8F

7,5

34

1520

490

1T x 10F

10

10

7,5

35

1580

500

1T x 12F

12

12

7,5

36

1530

450

2T x 6F

12

7,6

38

1550

780

2T x 12F

24

12

7,6

40

1530

450

4T x 6F

24

7,6

42

1550

780

3T x 12F

36

12

7,6

43

1530

450

6T x 6F

36

7,6

44

1550

780

4T x 12F

48

12

7,6

45

1530

450

5T x 12F

60

12

7,6

47

1530

450

6T x 12F

72

12

7,6

49

1530

450

8T x 12F

96

12

8,6

61

1620

450

12T x 12F

144

12

12

12

10,7

89

1750

910

Crush
[N/10cm]

Fully dielectric cable

LAN and FTTX networks

Distribution network

ODF connections

Features

1200

FRP strength and anti-buckling element

Optical fibers

Loose tube filled with jelly (PBT 1,6mm)

Dry yarns to prevent moisture into the cable

Fibreglass yarns as tensile elements

UV stabilized PE Sheath

LSOH, PA etc Sheath option

Operating temperature

Available colors

+100

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers in tube

+70C

10

11

12

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

Code
Color

temperature [C]

1-12

+55C

-15C

TRANSPORT

Total
elements

OPERATION

Fibers
per
tube

Fibers

Max. tensile load


[N]

INSTALLATION

Version

Applications
Nominal
weight
PE / LSOH

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Loose tubes in cables
Tube

10

11

12
-70C

Code
Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

-100

*For the cable with a multi-layer construction color of the tubes will be repeated in second layer.

datacom bdc-SSA cables | 27

datacom

DATACOM BDC-MSA

bdc-MSA

Cable structure
6. Loose Tubes (PBT)
with colored fibers
in filling gel
7. Fillers
8. Ripcord

1. PE Sheath
2. Water-blocking Fiberglass Yarns
3. Water blocking Yarns
4. Estrofol Tape
5. Central Strength
Member (FRP)

ETR

Datacom

Rodent
Protection Basic

LSOH

Compact design

4
5

Datacenter
Applications

Fibers

Fibers
per
tube

Total
elements

Active
tubes

Nominal
weight
LSOH
5%
[kg/km]

Nominal
weight PE
5%
[kg/km]

5%
[mm]

Max. tensile
load [N]
installation

operation

1T x 12F

12

12

8.2

50

65

1500

550

2T x 6F

12

8.2

50

65

1550

780

2T x 12F

24

12

8.2

51

65

1500

550

4T x 6F

24

8.2

51

66

1550

780

3T x 12F

36

12

8.2

52

67

1500

550

6T x 6F

36

8.2

53

68

1550

780

4T x 12F

48

12

8.2

53

68

1500

5T x 12F

60

12

8.2

54

69

1500

72

12

8.2

54

69

1500

Crush
[N/10cm]

Fully dielectric cable

Rodent protection cable

LAN and FTTX networks

Distribution network

ODF connections

Features

FRP strength and anti-buckling element

Optical fibers

Loose tube jelly filled (PBT 1,6mm)

Dry yarns to prevent moisture into the cable

550

Fibreglass yarns as tensile elements

550

UV stabilized PE Sheath

550

LSOH, PA etc Sheath option

8T x 12F

96

12

9.3

71

86

1620

750

12T x 12F

144

12

12

12

11,5

104

126

1620

850

1500

Operating temperature

Available colors

+100

DD-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers in tubes

+70C

10

11

12

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

Code
Color

DD-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Loose tubes in cable
Tube

10

-15C
-40C

11

12

Code
Color

+55C

-100

red

green

blue

white

violet

orange

grey

yellow

brown

*For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
**In case of lower fiber count some tubes can be replaced by fillers.

28 | datacom bdc-MSA cables

pink

black

aqua

TRANSPORT

OPERATION

INSTALLATION

temperature [C]

1-12

6
8

BDC-msa

6T x 12F

Configuration

Version

FTTH
Cables

VC-D20/VC-D30
VC-DCS/VC-DCY
SOLID CONNECTION TO YOUR PROVIDER

BEND

RESISTANCE

EASY TO

TERMINATE

LSOH

SAFE COVER

SMALL
DIMENSIONS

SAFE

DAILY USE

ftth

FTTH VC-D20

VC-d20

2
3

Cable structure
1. Outer Jacket LSOH ( white or ivory color)
2. High modulus Aramid Strength Yarns
3. Central Semi Tight Buffer Tube 900m
with colored fiber 250m

Last mile
connection outdore

Flexible Easy to terminate

LSOH

Bendsafe

FTTH

Configuration

Applications

VC-d20
No. of Fibers

Optical cable with Aramid yarns reinforcement

For customer connection

2,0

Fully dielectric cable

200/350

Last mile connection

LAN and FTTX networks

Distribution network

ODF connections

Inside house OLT connection

1F 900m

Outer diam [mm]


Tensile load perm/inst. [N]
Weight [kg/km]

Min. bend radius [mm]

10-60mm*

Crush [N/10cm]

300

*-depends on fiber type

Bend radius/maximum attenuation


Features

Aramid strength element

Optical fibers 900m semi tight

Outer jacket LSOH

Operating temperature
+100
+70C

-5C

TRANSPORT

+50C
OPERATION

0.30dB 0.20dB

G.652B3 Plus
0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

0.10dB 0.03dB

1.00dB 0.50dB

0.20dB 0.10dB

0.10dB 0.03dB

1.50dB 0.50dB

0.50dB 0.20dB

1.00dB 0.25dB

0.03dB

G.652B3 (A3)

INSTALLATION

7,5

G.652A2

temperature [C]

10

G.657A1

Max. attenuation for wavelength


1550 nm 1625nm/both [dB]

15

G.652D LL

0.03dB

30

0.03dB

Bend radius [mm]

40

0.03dB

60

1.00dB 0.25dB

G.652D

-20C
-40C

-100

ftth VC-D20 cables

| 31

ftth

FTTH VC-D30

VC-d30

Cable structure
1. Outer Jacket LSOH ( white or ivory color)
2. High modulus Aramid Strength Yarns
3. Central Semi Tight Buffer Tube 900m
with colored fiber 250m

Last mile
connection outdore

Flexible Easy to terminate

LSOH

2
3

Bendsafe

FTTH

Configuration
Applications

VC-d30
No. of Fibers

1F 900m

Optical cable with Aramid yarns reinforcement

3,0

For customer connection

Fully dielectric cable

Last mile connection

LAN and FTTX networks

10-60mm*

Distribution network

500

ODF connections

Inside house OLT connection

Outer diam [mm]


Tensile load perm/inst. [N]

200/350

Weight [kg/km]

Min. bend radius [mm]


Crush [N/10cm]
*-depends on fiber type

15
10
7,5

0.30dB 0.20dB

G.652B3 Plus
0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

G.652B3 (A3)
0.10dB 0.03dB

1.00dB 0.50dB

0.20dB 0.10dB

G.652A2
0.10dB 0.03dB

1.50dB 0.50dB

G.657A1
0.50dB 0.20dB

1.00dB 0.25dB

0.03dB

G.652D LL

0.03dB

0.03dB

30

0.03dB

Bend radius [mm]

40

1.00dB 0.25dB

G.652D

60

Max. attenuation for wavelength


1550 nm 1625nm/both [dB]

Bend radius/maximum attenuation


Features

Aramid strength element

Optical fibers 900m semi tight

Outer jacket LSOH

Operating temperature
+100

-20C
-40C

-100

32 | ftth VC-D30 cables

TRANSPORT

-5C

OPERATION

+50C
INSTALLATION

temperature [C]

+70C

ftth

FTTH VC-DCS

VC-dcs

Cable structure
1. Outer Jacket LSOH ( white or ivory color)
2. High modulus Aramid Strength Yarns
3. Semi Tight Buffer Tube 900m
with colored fiber 250m

Last mile
connection outdore

Flexible Easy to terminate

LSOH

Bendsafe

FTTH

Configuration
Applications

VC-dCS
No. of Fibers

Optical cable with Aramid yarns reinforcement

For customer connection

Fully dielectric cable

Last mile connection

LAN and FTTX networks

10-60mm*

Distribution network

900

ODF connections

Inside house OLT connection

1-2F 900m

Outer diam [mm]

4,0

Tensile load perm/inst. [N]

200/350

Weight [kg/km]

15

Min. bend radius [mm]


Crush [N/10cm]
*-depends on fiber type

Features

Aramid strength element,

Optical fibers 900m semi tight

Outer jacket LSOH

Operating temperature
+100
+70C
+50C

-5C

TRANSPORT

0.30dB 0.20dB

G.652B3 Plus
0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

G.652B3 (A3)
0.10dB 0.03dB

1.00dB 0.50dB

0.20dB 0.10dB

0.10dB 0.03dB

1.50dB 0.50dB

0.50dB 0.20dB

1.00dB 0.25dB

0.03dB

0.03dB

G.652A2

OPERATION

7,5

G.657A1

INSTALLATION

10

G.652D LL

temperature [C]

15

0.03dB

30

0.03dB

Bend radius [mm]

40

1.00dB 0.25dB

G.652D

60

Max. attenuation for wavelength


1550 nm 1625nm/both [dB]

Bend radius/maximum attenuation

-20C
-40C

-100

ftth VC-DCS cables

| 33

ftth

FTTH VC-DCY

VC-dcy

Last mile
connection outdore

Flexible Easy to terminate

LSOH

Bendsafe

FTTH

Cable structure
1. Outer Jacket LSOH
(white/ivory/black color)
2. Fiber Glass Rod
3. Optical Fibers 250m

Hi-crush

Configuration
Applications

VC-dCY
No. of Fibers

1-4F 900m

Outer diam [mm]

2,0x3,1 0,1

FTTH Drop able with Fiber Glass reinforcement


rods

For customer connection

50/100

Fully dielectric cable

8,3 1

Last mile connection

15-40mm*

LAN and FTTX networks

Distribution network

ODF connections

Inside house OLT connection

Tensile load perm/inst. [N]


Weight [kg/km]
Min. bend radius [mm]

Crush [N/10cm]

1000

*-depends on fiber type

15
10
7,5

0.30dB 0.20dB

G.652B3 Plus
0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

G.652B3 (A3)
0.10dB 0.03dB

1.00dB 0.50dB

0.20dB 0.10dB

G.652A2
0.10dB 0.03dB

1.50dB 0.50dB

G.657A1
0.50dB 0.20dB

1.00dB 0.25dB

0.03dB

G.652D LL

0.03dB

0.03dB

30

0.03dB

Bend radius [mm]

40

1.00dB 0.25dB

G.652D

60

Max. attenuation for wavelength


1550 nm 1625nm/both [dB]

Bend radius/maximum attenuation


Features

Fiber glass strength rods

Optical fibers 250m

Outer jacket LSOH

Operating temperature
+100

-30C

-100

34 | ftth VC-Dcy cables

TRANSPORT

OPERATION

INSTALLATION

temperature [C]

+70C
+55C

ftth

DC-PRIM

DC-PRIM
Cable structure

1. Outer Jacket LSOH


2. High modulus Aramid Strength Yarns
3. Optical Fibers 250m

2
3

TRUE
COLORS

LSOH

Bendsafe

Easy to terminate

Semi-tight

Easy-strip

Datacenter

Construction
Applications

DC-PRIM
No. of Fibers

12

24

Outer diameter [mm]

3,0

4,0

Tensile load perm/inst. [N]

350

450

20

45 (depends on fiber type)

60 (depends on fiber type)

Weight [kg/km]
Min. bend radius [mm]

Optical cable with Aramid yarns reinforcement

For customer connection, fully dielectric cable

MTP/MPO termination cable

LAN and FTTX networks

Distribution network

Inside house OLT connection

Data Center connections cable

Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304)
1

10

11

Fibre
Buffer
Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Aramid strength element

Optical fibers 250m (12-24)

Outer jacket LSOH

Operating temperature

Fibre

+100

Code
green

blue

yellow

white

grey

brown

violet

aqua

natural orange

pink

Color*

red

green

blue

yellow

white

grey

brown

violet

brown

dark
green

pink

600/900m

* - buffer with black ring for identification fibers 13-24

orange

+55C

-5C
-10C

TRANSPORT

red

250m

temperature [C]

+70C

Color

OPERTATION

250/600/900m

Features

12

INSTALATION

1-12

-25C

-100

ftth DC-PRIM

| 35

ftth

FTTH EAC-RAs

EAC-Ras

Cable structure

1. LSOH Outer Sheath


2. Semi Tight/Easy Strip Buffer 900m (LSOH)
with colored optical fiber 250m
3. Dielectric Strength Members in Jacket

Last mile
connection outdore

Flexible Easy to terminate

LSOH

Bendsafe

FTTH

Configuration
Applications

EAC-Ras
Version

Fibers

Nominal
weight
5%
[kg/km]

5%
[mm]

Total
elements

6F

7,5

43

12F

12

12

8,5

50

16F

16

16

10,0

65

24F

24

24

12,5

80

36F

36

36

13,5

110

48F

48

48

14,5

135

Max. tensile load [N]


installation

Crush
[N/10cm]

operation

600

360

1000

Vertical FTTH installation

Up to 25m module extraction

LSOH jacket

Indoor use

Bend safe fiber

Semi and easy strippable modules 900m

Easy to terminate

Features
Available colors
F-FTTH (according to 1xESFU) - Fibers in tubes
1

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

Fibre
Tube

Optical fibers 900m

Outer jacket LSOH

EAC - Easy Access Cable

Operating temperature
+100

Fibre

25-36

25

26

27

28

29

30

31

32

33

34

35

36

Fibre
Tube
37-48

37

38

39

40

41

42

43

44

45

46

47

48

Fibre

-5C

TRANSPORT

Tube

temperature [C]

+70C

OPERATION

13-24

Aramid strength element

INSTALLATION

1-12

-20C
-40C

-100

Tube

Fiber extraction up to 25m


Color codes
Color
Code

red

blue

green yellow

36 | ftth EAC-RA cables

violet

white

orange

grey

brown

black

aqua

light
green

dark
green

pink

Fiber extraction

ftth

FTTH EAC-RAd

EAC-RAd

Cable structure
1. LSOH Outer Sheath
2. Semi Tight/Easy Strip Buffer 900m
(2 pcs coloured fibers 250m
in one bundle)
3. Dielectric Strength Members in Jacket

Last mile
Last mile
connection
outdore
connection outdore

Flexible Easy to terminate

LSOH

Bendsafe

FTTH

Construction

EAC-RAd
Version

Fibers

6T x 2F

Total
elements

12

12T x 2F

24

12

Applications

5%
[mm]

Nominal
weight
5%
[kg/km]

7,5
8,5

Max. tensile load [N]

Vertical FTTH installation

Up to 25m module extraction

LSOH jacket

43

Indoor use

56

Bend safe fiber

Semi and easy strippable modules 900m

Easy to terminate

16T x 2F

36

16

10,5

72

24T x 2F

48

24

12,5

88

installation

Crush
[N/10cm]

operation

600

360

1000

0.30dB 0.20dB

G.652B3 Plus
0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

0.10dB 0.03dB

G.652B3 (A3)

1.00dB 0.50dB

0.20dB 0.10dB

0.10dB 0.03dB

G.652A2

1.50dB 0.50dB

0.50dB 0.20dB

G.657A1

1.00dB 0.25dB

0.03dB

0.03dB

0.03dB

15
10
7,5

F-FTTH (according to 2xESFU) - Fibers in tubes


1

Aramid strength element

Optical fibers 900m

Outer jacket LSOH

EAC - Easy Access Cable

Operating temperature
6

10

11

12

+100

Fibre

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Fibre
Tube
25-36

25

26

27

28

29

30

31

32

33

34

35

36

-5C
-20C

TRANSPORT

Tube

temperature [C]

+70C

OPERTATION

1-12

Features

INSTALATION

30

0.03dB

Bend radius [mm]

40

G.652D LL

1.00dB 0.25dB

G.652D

60

Max. attenuation for wavelength


1550 nm 1625nm/both [dB]

Bend radius/maximum attenuation

-40C

Fibre

-100

Tube
37-48

37

38

39

40

41

42

43

44

45

46

47

48

Fiber extraction up to 25m

Fibre
Fiber extraction

Tube

Color codes
Color
Code

red

blue green yellow violet white orange grey brown black aqua

light dark
green green

pink red/blue

ftth EAC-RA cables | 37

ftth

FTTH DAC-BURRY

DAC-Burry

Cable structure

1. PP/PE Outer Sheath


2. High modulus Aramid Strength Yarns
3. Central Loose Tube (PBT)
with colored fibers 250m in filling gel
4. Dielectric strength members in the jacket

Direct buried

Last mile
connection outdore

FTTH

Hi-crush

Applications

DAC-BURRY
Fibers
per tube

Fibers

Nominal
weight PE
5%
[kg/km]

5%
[mm]

1T x 2F

6.2

32

1T x 4F

6.2

32

1Tx 6F

6.2

32

1T x 8F

6.2

32

1T x 12F

12

12

6.2

32

Max. tensile load [N]


installation

operation

650

Crush
[N/10cm]

250

Optical access cable with Aramid yarns reinforcement

Direct buried construction

Fully dielectric cable

Last mile connection

Very strong construction 4kN crush

Installation into existing ducts or direct buried

4000

Features

*-depends on fiber type

Available colors
T-Telecom (according to IEC 60304) - Fibers in tube
1-12

Compact design

Configuration

Version

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Aramid strength elements

Optical fibers

Loose tube filled with jelly

Loose tube (PBT)

Embedded strength members (FRP)

High resistant jacket of hard polyolefin material,


UV resistant

Code
Color

Operating temperature
+100

-30C

-100

38 | ftth DAC-BURRY cables

TRANSPORT

OPERATION

INSTALLATION

temperature [C]

+70C
+55C

ftth

FTTH aero-df03

aero-df03
Cable structure
4. Central Loose Tube (PBT)
with colored fibers
250m in filling gel
5. FRP Reinforcement
Strength Member

1. PE Sheath
2. Ripcord
3. Water blocking Yarns

Last mile
connection outdore

Aerial

2
4

Telecom

Hi-crush

FTTH

Cable variants
Version

AERO-DF03

AERO-DF03

Fiber count

1-12

16-24

Cable dimensions [mm]

8,3 x 4.6 (3%)

8,7 x 5,0 (3%)

Cable weight [kg/km]

37

38

Max. installation tension[N]

1300

1300

Applications

Mechanical and enviromental characteristics

For installation on poles or walls

Can be installed in pipelines

Fully dielectric cable

Parameter
Crush performance

5000N

Bending performance

10 [cycles 20 x D]

Water Penetration

3m sample, 1m head, 24h

Features

Available colors
T-Telecom (according to IEC 60304) - Fibers in tube
1-12

10

11

12

Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

red

green

blue

white

violet

orange

grey

yellow

brown

pink

natural

aqua

Loose tube jelly filled (PBT)

Up to 24 fibers in a cable

Two FRP strength elements

Dry yarns to prevent moisture into cable

Ripcord Yarns For easy sheath removal

PE UV resistant Sheath

Code

Operating temperature
+100

Code

span: 120m

-10C

TRANSPORT

NESC Light

OPERATION

*In case of 24 fibers tube construction colors will be repeated and for easier identification fibers 13-24 will have rings every 25cm.

INSTALLATION

+70C
temperature [C]

Color

-40C
sag: 2.4m

-100
NSC Medium
span: 70m

sag: 1.4m

NESC Heavy
span: 40m

sag: 0.8m

ftth AERO-DF03 cables | 39

Microduct

TRENCH

MICROCABLES

OPTIMAL
DIAMETER
BLOWING
PERFORMANCE
HIGH FIBERS
DENSITY

LOW FRICTION
FORCE

COMPACT
DESIGN

microduct MK-AX2

MICRODUCT MK-AX2
1

Cable structure
1. Polymeric sheath with low coefficient
of friction
2. Colored fibers 250m

Microduct
Generation 1

Last mile
Blowing
connection outdore installation

FTTH

Bendsafe

Compact design

Flexible

Configuration

MetroJET MK-AX2
Version

Fibers

5% [mm]

1T x 2F

1.1

1.2

1T x 4F

1.1

Max. install.
tension [N]

Crush
[N/10cm]

Microcanalization air-blowing application

Metro networks

1.4

Flexible network design

Distribution network

1T x 8F

1.5

1.8

10

1.6

2.0

1T x 12F

12

1.6

2.2

15

100

Features

Compatibility table

standard microduct
Outer
[mm]

MK-AX2

Inner
[mm]

Direct burried ducts

2-4F

6-12F

Outer
[mm]

Inner
[mm]

7/3,5

3.5

Version

2-4F

6-12F

2.1

5/3,5

3.5

7/3,8

3.8

7/5,5

5.5

7/4

10/8

10

10/5,5

10

5.5

12/10

12

10

12/8

12

12

14/10

14

10

14/12

14

Fiber qnt

2-12

Fiber qnt

Polymeric sheath with low coefficient of friction

Central tube without gel

250m colored fibers

MK-AX2

3/2,1

Operating temperature
+100
+60C

2-12

+70C

-10C
-30C

Available colors
-100

42 | Microduct MK-AX2

TRANSPORT

1.6

OPERATION

1.5

INSTALLATION

1T x 10F

Version

Applications

temperature [C]

1T x 6F

Nominal weight 10%


[kg/km]

microduct MK-DX2/25

MICRODUCT MK-DX2/25
1

Cable structure

1. HDPE with low coefficient of friction


2. Aramid Yarns
3. Central Loose Tube (PBT) with colored
fibers 250m in filling gel

Microduct
Generation 1

Last mile
Blowing
connection outdore installation

FTTH

Bendsafe

Compact design

Flexible

MetroJET MK-DX2/25
Nominal
weight 10%
[kg/km]

2.0

3,9

1T x 4F

2.0

3.9

1T x 6F

2.3

4.4

1T x 8F

2.3

4.5

1T x 10F

10

2.3

4.6

1T x 12F

12

2.3

4.6

Applications

Crush

300

500

direct burried ducts

MK-DX2

MK-DX25

3/2,1

2.1

5/3,5

3.5

7/5,5

5.5

10/8

10

12/10

12

10

14/12

14

12

Version

[mm]

[mm]

Fiber qnt

FTTH & Distribution networks

Flexible network design

Last mile connection

For blowing & pulling installation method

Outer

Inner

7/3,5

3.5

7/3,8

3.8

7/4

10/5,5

10

5.5

12/8

12

14/10

14

10

2-4

4-12

Version

[mm]

[mm]

Fiber qnt

MKDX2

MKDX25
-

HDPE with low coefficient of friction

Aramid yarns

Central tube with gel

250m colored fibers

Microbending resistant fiber G657A1 as standard

Operating temperature
+100
+60C

2-4

4-12

+70C

temperature [C]

standard microduct
Inner

Microduct cabling system application

Features

Compatibility table
Outer

-10C

TRANSPORT

1T x 2F

Max. installation
tension [N]

OPERATION

5%
[mm]

Fibers

INSTALLATION

Version

-30C

Available colors
T-Telecom (according to IEC 60304) - Fibers in tube
1-12

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

-100

Code
Color

Microduct MK-DX2 | 43

microduct MK-LX4

MICRODUCT MK-LX4

Cable structure (MK-LX4)


5. Waterblocking Yarns
1. Outer Sheath: HDPE
6. Waterblocking Yarns
2. Loose Tubes (PBT)
on Strand Element
with colored fibers in
7. Ripcord
filling gel
3. Fillers
4. Central Strength
Member (FRP)

5
6

7
Optimal
diameter

Low Friction

Blowing
installation

Telecom

Microduct
Generation 1
Applications

Configuration

MetroJET MK-LX4
Fillers

Fibers

1T x 4F

4.2

2T x 4F

4.2

3T x 4F

12

4.2

4T x 4F

16

4.2

5T x 4F

20

4.2

10

6T x 4F

24

4.2

10

installation

operation

Crush
[N/10cm]

Metro networks

Flexible network design

Distribution network

Features
250

150

500

Other Fiber counts available on demand

HDPE, UV resistance external jacket with low


friction

Loose tubes (and fillers), SZ stranded around


the CSM

Each PBT tubes containing 4 optical fibers

Smallest outer diameter for blowing into 5.5mm


(ID) ducts

Compatibility table

Version

Outer

Inner

2.1

[mm]

3/2,1

MK-LX4

[mm]

5/3,5

3.5

7/5,5

5.5

10/8

10

12/10

12

10

14/12

14

12

Direct burried ducts

Fiber qnt

4-24

Version
7/3,5

Outer
[mm]

Inner

3.5

Operating temperature

MK-LX4

[mm]

+100

7/3,8

3.8

7/4

10/5,5

10

5.5

12/8

12

14/10

14

10

Fiber qnt

+55C

+70C
+60C

temperature [C]

standard microduct

-5C

-30C
-40C

4-24

-100

Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12

Code
Color

Tubes T-Telecom (according to IEC 60304) - Tubes


Tube

red

green

blue

white

violet

orange

Code
red

green

blue

white

44 | Microduct MK-LX4

Color

TRANSPORT

Version

Max. tensile
load [N]

OPERATION

Active
tubes

Nominal
weight
10%
[kg/km]

Microduct cabling air-blowing system application

INSTALLATION

Total
elements

5%
[mm]

Fibers
per
tube

microduct MK-LXs6/7/8

MICRODUCT MK-LXS6/7/8

Cable structure (MK-LXS6)


1. Outer Sheath: HDPE
2. Loose Tubes (PBT) with colored fibers
in filling gel
3. Fillers
4. Central Strenght Member (FRP)
5. Waterblocking Yarns on FRP
6. Waterblocking Yarns on Strand
Element
7. Ripcord

5
6

Optimal
diameter

Low Friction

Blowing
installation

Telecom

Microduct
Generation 1

Configuration
Applications

MetroJET MK-LXS6

5.3

18

6T x 6F

36

5.3

18

6T x 8F

48

5.3

19

6T x 10F

60

10

5.3

19

6T x 12F

72

12

5.3

21

operation

[N/10cm]

650

200

500

MetroJET MK-LXS7
Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

Fillers

5%
[mm]

Nominal
weight
10%
[kg/km]

8T x 4F

32

6.2

28

8T x 6F

48

6.2

28

8T x 8F

64

6.2

29

8T x 10F

80

10

6.2

30

8T x 12F

96

12

6.2

31

Max. tensile
load [N]
installation

operation

Crush
[N/10cm]

1000

1200

350

reversible,
fiber strain
0.5%

MetroJET MK-LXS8
Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

Fillers

5%
[mm]

Nominal
weight
10%
[kg/km]

12T x 4F

48

12

12

7.9

47

12T x 6F

72

12

12

7.9

48

12T x 8F

96

12

12

7.9

49

12T x 10F

120

10

12

12

7.9

50

12T x 12F

144

12

12

12

7.9

52

Max. tensile
load [N]
installation

operation

Microduct cabling air-blowing system application

Metro networks

Flexible network design

Distribution network

Features

HDPE, UV resistance external jacket with low


friction

Loose tubes (and fillers), SZ stranded around


the CSM

Each PBT tubes containing 4-12 optical fibers

Operating temperature
+100 +100
+70C +70C
+60C
+55C+55C

-5C

TRANSPORT

installation

TRANSPORT

24

Crush

OPERATION

6T x 4F

Max. tensile
load [N]

OPERATION

Nominal
weight
10%
[kg/km]

INSTALLATION

Fillers

5%
[mm]

INSTALLATION

Active
tubes

temperature [C]

Fibers

Total
elements

temperature [C]

Version

Fibers
per
tube

-30C
-30C

-40C

Crush
[N/10cm]

-100

-100

1000

1500

550

reversible,
fiber strain
0.5%

Other Fiber counts available on demand

microduct MK-LXS6/7/8 | 45

microductMK-LX6

MICRODUCT MK-LX6
Cable structure (MK-LX6)
1. Outer Sheath: HDPE
2. Loose Tubes (PBT) with colored fibers
in filling gel
3. Fillers
4. Central Strenght Member (FRP)
5. Waterblocking Yarns on FRP
6. Waterblocking Yarns on Strand Element
7. Ripcord

5
6

Optimal
diameter

Low Friction

Blowing
installation

Telecom

Microduct
Generation 1

Configuration

MetroJET MK-LX6
Version

Fibers
per
tube

Fibers

Total
elements

Active
tubes

Fillers

5%
[mm]

Nominal
weight
10%
[kg/km]

1T x 4F

5.6

28

1T x 6F

5.6

28

1T x 8F

5.6

28

2T x 6F

12

5.6

29

4T x 6F

24

5.6

29

6T x 6F

36

5.6

29

1T x 12F

12

12

5.6

30

2T x 12F

24

12

5.6

30

3T x 12F

36

12

5.6

30

4T x 12F

48

12

5.6

31

5T x 12F

60

12

5.6

32

6T x 12F

72

12

5.6

33

Max. tensile
load [N]
installation

operation

Applications
Crush
[N/10cm]

Microduct cabling air-blowing system application

Metro networks

Flexible network design

Distribution network

Features
1000

750

250

reversible,
fiber strain
0.5%

HDPE, UV resistance external jacket with low


friction

Loose tubes (and fillers), SZ stranded around


the CSM

Each PBT tubes containing 4-12 optical fibers

Smallest diameter for blowing into 8mm (ID)


ducts

Operating temperature

Other Fiber counts available on demand

+100

10

11

12

Code
Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

-5C

-30C
-40C

T-Telecom (according to IEC 60304) - Tubes


Tube

red

green

blue

white

violet

orange

Code
Color

*In case of lower fiber count some tubes can be replaced by filler

46 | Microduct MK-LX6

-100

TRANSPORT

1-12

OPERATION

T-Telecom (according to IEC 60304) - Fibers

+70C
+60C

temperature [C]

+55C

INSTALLATION

Available colors

microductMK-LX7

MICRODUCT MK-LX7

Cable structure (MK-LX7)


1. Outer Sheath: HDPE
2. Loose Tubes (PBT) with colored fibers
in filling gel
3. Fillers
4. Central Strenght Member (FRP)
5. Waterblocking Yarns on FRP
6. Waterblocking Yarns on Strand Element
7. Ripcord

4
5
6

Optimal
diameter

Low Friction

Blowing
installation

Telecom

Microduct
Generation 1

Configuration

Applications

MetroJET MK-LX7
Version

Fibers
per
tube

Fibers

Total
elements

Active
Fillers
tubes

5%
[mm]

Max. tensile load


[N]

Nominal
weight
10%
[kg/km]

8T x 4F

32

6.7

36

8T x 6F

48

6.7

37

8T x 8F

64

6.7

38

8T x 12F

96

12

6.7

39

installation

operation

1600

600

Crush
[N/10cm]

Microduct cabling air-blowing system application

Metro networks

Flexible network design

Distribution network

1000

Other Fiber counts available on demand


Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Features

HDPE, UV resistance external jacket with low


friction

Loose tubes (and fillers), SZ stranded around


the CSM

Each PBT tubes containing 4-12 optical fibers

Smallest diameter for blowing into 8* and 10mm


(ID) ducts

Code

Operating temperature

Code
Color

+100

8
+55C

red

green

blue

white

violet

orange

*In case of lower fiber count some tubes can be replaced by filler

grey

yellow

+70C
+60C

-5C

TRANSPORT

OPERATION

INSTALLATION

T-Telecom (according to IEC 60304) - Tubes


Tube

* - the blowing is possible only with lower blowing range

temperature [C]

Color

-30C
-40C

-100

Microduct MK-LX7 | 47

microductMK-LX8

MICRODUCT MK-LX8
Cable structure
1. Outer Sheath: HDPE
2. Loose Tubes (PBT) with colored fibers
in filling gel
3. Fillers
4. Central Strenght Member (FRP)
5. Waterblocking Yarns on FRP
6. Waterblocking Yarns on Strand Element
7. Ripcord

3
4
5

Optimal
diameter

Low Friction

Blowing
installation

Telecom

Microduct
Generation 1

Configuration
Applications

MetroJET MK-LX8
Fillers

5%
[mm]

Nominal
weight
10%
[kg/km]

1T x 12F

12

12

12

11

8.6

53

2T x 12F

24

12

12

10

8.6

54

3T x 12F

36

12

12

8.6

55

4T x 12F

48

12

12

8.6

56

5T x 12F

60

12

12

8.6

57

6T x 12F

72

12

12

8.6

57

8T x 12F

96

12

12

8.6

59

12T x 12F

144

12

12

12

8.6

62

Max. tensile
load [N]
installation

operation

2500

600

Crush
[N/10cm]

Available colors
2

10

11

Flexible network design

Distribution network

HDPE, UV resistance external jacket with low


friction

Loose tubes (and fillers), SZ stranded around


the CSM

Each PBT tubes containing 4-12 optical fibers

Smallest diameter for blowing into 12mm (ID)


ducts

+100

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

+70C
+60C

temperature [C]

+55C

T-Telecom (according to IEC 60304) - Tubes


Tube

12

Code
Color

Metro networks

Operating temperature

T-Telecom (according to IEC 60304) - Fibers


1

Microduct cabling air-blowing system application

Features
1000

Other Fiber counts available on demand

1-12

-5C

-30C
-40C

Code
Color

*In case of lower fiber count some tubes can be replaced by filler

48 | Microduct MK-LX8

-100

TRANSPORT

Active
tubes

OPERATION

Fibers

Total
elements

INSTALLATION

Version

Fibers
per
tube

microductMK-LX9

MICRODUCT MK-LX9
Cable structure
1. Outer Sheath: HDPE
2. Loose Tubes (PBT) with colored fibers
in filling gel
3. Fillers
4. Central Strenght Member (FRP)
5. Waterblocking Yarns on FRP
6. Waterblocking Yarns on Strand Element
7. Ripcord

5
6

Optimal
diameter

Low Friction

Blowing
installation

Telecom

Microduct
Generation 1

Configuration

Applications

MetroJET MK-LX8
Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

Fillers

5%
[mm]

Nominal
weight
10%
[kg/km]

14T x 12F

168

12

18

14

9.2

62

16T x 12F

192

12

18

16

9.2

63

18T x 12F

216

12

18

18

9.2

64

Max. tensile
load [N]
installation

operation

750

250

Crush
[N/10cm]

Microduct cabling air-blowing system application

Metro networks

Flexible network design

Distribution network

1000

Features

Other Fiber counts available on demand


Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

HDPE, UV resistance external jacket with low


friction

Loose tubes (and fillers), SZ stranded around


the CSM

Each PBT tubes containing 12 optical fibers

Smallest diameter for blowing into 12mm (ID)


ducts

Code

Operating temperature
+100

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code
Color

*For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
**In case of lower fiber count some tubes can be replaced by fillers.

+55C

+70C
+60C

-5C

TRANSPORT

temperature [C]

Tube

OPERATION

T-Telecom (according to IEC 60304) -Tubes

INSTALLATION

Color

-30C
-40C

-100

Microduct MK-LX9 | 49

microductMK-LX11

MICRODUCT MK-LX11

Cable structure
1. Outer Sheath: HDPE
2. Fillers
3. Loose Tubes (PBT) with colored fibers
in filling gel
4. Central Strenght Member (FRP)
5. Waterblocking Yarns on FRP
6. Waterblocking Yarns on Strand Element
7. Ripcord

Optimal
diameter

Low Friction

Blowing
installation

Telecom

5
6

Microduct
Generation 1

Configuration
Applications

MetroJET MK-LX11
Fillers

Nominal
weight

5%
[mm]

10%
[kg/km]

20T x 12F

240

12

24

20

10.8

85

22T x 12F

264

12

24

22

10.8

86

24T x 12F

288

12

24

24

10.8

87

Max. tensile
load [N]
installation

operation

900

350

Crush
[N/10cm]

Microduct cabling air-blowing system application

Metro networks

Flexible network design

Distribution network

1000

Features

Other Fiber counts available on demand


Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

HDPE, UV resistance external jacket with low


friction

Loose tubes (and fillers), SZ stranded around


the CSM

Each PBT tubes containing 12 optical fibers

Smallest outer diameter for blowing into 12mm


(ID) ducts

Code

Operating temperature

T-Telecom (according to IEC 60304) - Tubes


Tube

10

11

+55C

Code
Color

+100

12

red

green

blue

white

violet

orange

grey

yellow

brown

*For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
**In case of lower fiber count some tubes can be replaced by fillers.

pink

black

aqua

+70C
+60C

temperature [C]

Color

-5C

-30C
-40C

-100

50 | Microduct MK-LX11

TRANSPORT

Active
tubes

OPERATION

Fibers

Total
elements

INSTALLATION

Version

Fibers
per
tube

temperature [C]

-5C

-30C
-40C

-100

TRANSPORT

OPERATION

INSTALLATION

Telecom
Duct

+100

+70C
+55C

telecom ductBDC-SI

TELECOM DUCT BDC-SI


1

Cable structure
1. PE Sheath
2. Fiberglass Yarns
3. Water blocking Yarns
7
4. Water blocking Yarns on Stranded Elements
5. Central Strength Member (FRP)
5
6. Loose Tubes (PBT) with colored fibers
in filling gel
7. Fillers (Loose tubes with 1 pcs. mechanical fiber)
8. Ripcord
Rodent
Protection Basic

Telecom

4
6
8

Duct

Configuration

telecom duct bdc-si

5%
[mm]

Active
tubes

10%
[kg/km]

installation

operation

2T x 6F

12

45

2710

1200

1T x 12F

12

12

47

2790

800

4Tx 6F

24

46

2710

1200

2T x 12F

24

12

48

Crush
[N/10cm]

For installation into existing duct

Good resistance to traction and compression

Fully dielectric cable

Improved rodent protection

Features

3Tx 12F

36

12

49

4T x 12F

48

12

50

5T x 12F

60

12

51

6T x 12F

72

12

52

8T x 12F

96

12

64

2710

930

12T x 12F

144

12

12

12

10,9

97

2800

1100

24T x 12F

288

12

24

24

12,9

105

2710

980

2790

800

2000

HDPE, UV resistance external jacket with low


friction

Loose tubes (and fillers), SZ stranded around


the CSM

Each PBT tubes containing 12 optical fibers

Operating temperature
+100

Other Fiber counts available on demand


Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12

10

11

12

Code
Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

t-telecom - Loose tube in cable (according to IEC 60304) - Tubes


Tube

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

*For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
**In case of lower fiber count some tubes can be replaced by fillers.

52 | telecom duct BDC-SI

-15C
-40C

-100

Code
Color

temperature [C]

+70C
+55C
TRANSPORT

Total
elements

Applications

OPERATION

Fibers
per
tube

Fibers

Max. tensile
load [N]

INSTALLATION

Version

Nominal
weight

telecom ductbdc-MSA

TELECOM DUCT BDC-MSA


1

Cable structure

1. PE Sheath
2. Fiberglass Yarns
3. Water blocking Yarns
7
4. Water blocking Yarns on Stranded Elements
5
5. Central Strength Member (FRP)
6. Loose Tubes (PBT) with colored fibers
in filling gel
7. Fillers (Loose tubes with 1 pcs. mechanical fiber)
8. Ripcord
Rodent
Protection Basic

6
8

Duct

Configuration

Applications

telecom duct BDC-msa

1T x 12F

12

12

Total
elements
6

Active
tubes

Nominal
weight PE
5%
[kg/km]

8.2

50

Max. tensile load


[N]
installation

operation

1500

550

2T x 6F

12

8.2

50

1550

780

2T x 12F

24

12

8.2

51

1500

550

4T x 6F

24

8.2

51

1550

780

3T x 12F

36

12

8.2

52

1500

6T x 6F

36

8.2

53

1550

Crush
[N/10cm]

For installation into existing duct

Good resistance to traction and compression

Fully dielectric cable

Features

PE Outer Sheath

Optical fibers

550

Jelly into the loose tube

780

Loose tube (PBT 1.8mm )

Estrofol tape to prevent moisture into the cable

4T x 12F

48

12

8.2

53

1500

550

5T x 12F

60

12

8.2

54

1500

550

6T x 12F

72

12

8.2

54

1500

550

8T x 12F

96

12

9.3

71

1620

750

12T x 12F

144

12

12

12

11,5

104

1620

850

1500

Operating temperature
+100

Other Fiber counts available on demand


Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12

10

11

12

Code
Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

t-telecom - Loose tube in cable (according to IEC 60304) - Tubes


Tube

24

13
1

10

23

black

Color

11

15

red

green

blue

white

LSOH Grey RAL7022

violet

orange

grey

yellow

brown

-40C

12

16

21

PE Black RAL9005

-15C

-100

14
2

22

Code

aqua

temperature [C]

+70C
+55C
TRANSPORT

Fibers

5%
[mm]

INSTALLATION

Version

Fibers
per
tube

OPERATION

Telecom

17
20

19

pink

18

black

aqua

LSOH Light Grey RAL7037

*In case of lower fiber count some tubes can be replaced by filler

SM G.652D RAL 1021

SM G657 A1, A2, A3


RAL 9010

MM 50/1025 OM2
RAL9018

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

telecom duct BDC-MSA | 53

telecom ductBDC-c0

TELECOM DUCT BDC-C0


1

Cable structure

Rodent
Protection Basic

Telecom

1. PE Sheath
2. Waterblocking Fiberglass
Yarns
3. Water blocking Yarns
4. Water blocking tape
5. Central Strength
Member (FRP)

Duct

2
5

6. Loose Tubes (PBT)


with colored fibers 3
in filling gel
7
7. Fillers
8. Ripcord

6
8

Configuration

telecom duct bdc-c0


Max. tensile
load [N]

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

installation

operation

10.0

71

2080

1290

10.0

71

2080

1290

Version

Fibers

Fibers
per
tube

1T x 4F

1T x 6F

2T x 6F

12

4T x 6F

24

1T x 12F

12

12

2T x 12F

24

12

3T x 12F

36

12

4T x 12F

48

12

5T x 12F

60

12

6T x 12F

72

12

8T x 12F

96

12

11.3

97

2020

12T x 12F

144

12

12

12

13,8

141

2140

10.1

74

2000

1000

Crush
[N/10cm]

Applications

For installation into existing duct

Good resistance to traction and compression

Fully dielectric cable

Improved rodent protection

2000

Features

FRP strength and anti-buckling element

Optical fibers

1100

Loose tube jelly filled (PBT 2.0mm)

1060

Dry yarns to prevent moisture into the cable

Fibreglass yarns as tensile elements

UV stabilized PE Sheath

16T x 12F

192

12

16

16

13,7

136

2020

1100

18T x 12F

216

12

18

18

14,0

147

2125

1280

24T x 12F

288

12

24

24

16.2

190

2850

1660

Other Fiber counts available on demand

Operating temperature
+100

Available colors
3

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

10

11

12

Code
Color

t-telecom - Loose tube in cable (according to IEC 60304) - Tubes


Tube

-40C

-100

Code
Color

-15C

red

green

blue

white

violet

orange

grey

yellow

brown

*For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
**In case of lower fiber count some tubes can be replaced by fillers.

54 | telecom duct BDC-C0

pink

black

aqua

TRANSPORT

OPERATION

temperature [C]

1-12

INSTALLATION

+70C
+55C

T-Telecom (according to IEC 60304) - Fibers

telecom ductBDC-CI

TELECOM BDC-CI
1

Cable structure

Rodent
Protection Basic

Telecom

Duct

Configuration

6. Loose Tubes (PBT)


with colored fibers
in filling gel
7. Fillers
8. Ripcord

1. PE Sheath
2. Waterblocking Fiberglass
Yarns
3. Water blocking Yarns
4. Water blocking tape
5. Central Strength
Member (FRP)

7
6
8

telecom duct bdc-cI


Max. tensile
load [N]

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

installation

operation

10.0

74

2700

1660

10.0

74

2800

1600

Version

Fibers

Fibers
per
tube

1T x 4F

1T x 6F

2T x 6F

12

1T x 12F

12

12

10.1

73

2700

1400

4Tx 6F

24

10.0

74

2800

1600

2T x 12F

24

12

10.1

75

2700

1400

3Tx 12F

36

12

4T x 12F

48

12

10.1

82

2800

1400

6T x 12F

72

12

8T x 12F

96

12

11.4

98

2900

1600

12T x 12F

144

12

12

12

13,8

107

2950

1460

13T x 12F

156

12

18

13

14,2

109

14T x 12F

168

12

18

14

14,2

110

15T x 12F

180

12

18

15

14,2

111

16T x 12F

192

12

18

16

14,2

112

17T x 12F

204

12

18

17

14,2

113

18T x 12F

216

12

18

18

14,2

117

24T x 12F

288

12

24

24

16.3

191

2850

1200

2850

1660

Crush
[N/10cm]

Applications

For installation into existing duct

Good resistance to traction and compression

Fully dielectric cable

Improved rodent protection

Features
2000

FRP strength and anti-buckling element

Optical fibers

Loose tube jelly filled (PBT 2.0mm)

Dry yarns to prevent moisture into the cable

Fibreglass yarns as tensile elements

UV stabilized PE Sheath

LSOH, PA etc Sheath option

Operating temperature
+100

Other Fiber counts available on demand

+70C

10

red

green

blue

white

violet

orange

grey

yellow

brown

Code
24

Color

13
1

pink

23

11

12

black

aqua

14
2

15

22

t-telecom - Loose tube in cable (according to IEC 60304) - Tubes


Tube

16

21
20

19

18

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

LSOH Grey RAL7022

LSOH Light Grey RAL7037

-40C

17

PE Black RAL9005

-15C

TRANSPORT

OPERATION

1-12

+55C
INSTALLATION

T-Telecom (according to IEC 60304) - Fibers

temperature [C]

Available colors

-100

Code
Color

*For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
**In case of lower fiber count some tubes can be replaced by fillers.

SM G.652D RAL 1021

SM G657 A1, A2, A3


RAL 9010

MM 50/1025 OM2
RAL9018

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

telecom duct BDC-CI | 55

telecom ductddc-SI

TELECOM DUCT DDC-SI


1

Cable structure

1. PE Outer Sheath
2. Fiberglass Yarns
3. PE Inner Sheath
4. Water blocking Yarns
5. Central Strength Member (FRP)
6. Loose Tubes (PBT)
with colored fibers in filling gel
7. Fillers
8. Ripcords

Rodent
Protection High

Telecom

Duct

4
5

Direct buried

Configuration
Applications

telecom duct DDC-SI


Total
elements

Active
tubes

5%
[mm]

Nominal
weight

Version

Fibers

Fibers
per
tube

1T x 12F

12

12

8,6

60

2T x 12F

24

12

8,6

61

3T x 12F

36

12

8,6

61

4T x 12F

48

12

8,6

62

5T x 12F

60

12

8,6

63

6T x 12F

72

12

8,6

63

8T x 12F

96

12

9,0

68

12T x 12F

144

12

12

12

11,5

108

16T x 12F

192

12

18

16

11,6

108

18T x 12F

216

12

18

18

11,6

110

24T x 12F

288

12

24

24

13,3

129

10%
[kg/km]

Max. tensile
load [N]
installation

2750

operation

Crush
[N/10cm]

For installation into existing duct


or directly buried

Good resistance to traction and compression

Fully dielectric cable

Rodent Retardant cable

650

Features
2000

2808

670

2750

650

Other Fiber counts available on demand

FRP strength and anti-buckling element

Optical fibers

Loose tube jelly filled (PBT 1.6mm)

Dry yarns to prevent moisture into the cable

Fibreglass yarns as tensile elements

Double PE Sheath

Operating temperature

Available colors

+100

T-Telecom (according to IEC 60304) - Fibers


4

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code
Color

-15C

t-telecom - Loose tube in cable (according to IEC 60304) - Tubes


Tube

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code
Color

-40C

-100

*For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
**In case of lower fiber count some tubes can be replaced by fillers.

56 | telecom duct DDC-SI

TRANSPORT

OPERATION

INSTALLATION

temperature [C]

1-12

+70C
+55C

telecom ductDDC-c0

TELECOM DDC-C0
1

Cable structure
1. PE Outer Sheath
2. Fiberglass Yarns
3. PE Inner Sheath
4. Water blocking
Yarns
5. Central Strength
Member (FRP)

4
5

Rodent
Protection High

Telecom

6. Loose Tubes (PBT)


with colored fibers
in filling gel
7. Fillers
8. Ripcords

Duct

Direct buried

Hi-crush

Configuration
Applications

telecom duct DDC-c0


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

1T x 6F

11.7

92

2T x 6F

12

11.7

93

4T x 6F

24

11.7

95

1T x 12F

12

12

11.8

97

2T x 12F

24

12

11.8

98

3T x 12F

36

12

11.8

99

4T x 12F

48

12

11.8

101

6T x 12F

72

12

11.8

Max. tensile
load [N]
installation

Crush
[N/10cm]

operation

3700

For installation into existing duct


or directly buried

Good resistance to traction and compression

Fully dielectric cable

Rodent Retardant cable

1800

Features

FRP strength and anti-buckling element

Optical fibers

Loose tube jelly filled (PBT 2.0mm)

103

Dry yarns to prevent moisture into the cable

Fibreglass yarns as tensile elements

Double PE Sheath

LSOH, PA etc Outer Sheath option

3500

3000

1600

8T x 12F

96

12

13,0

126

3500

1700

12T x 12F

144

12

12

12

15,5

178

3500

1600

24T x 12F

288

12

24

24

17.6

229

3800

1500

Other Fiber counts available on demand


Operating temperature

Available colors
T-Telecom (according to IEC 60304) - Fibers
4

+100

10

11

12

Code
Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink
24

t-telecom - Loose tube in cable (according to IEC 60304) - Tubes


Tube

Code
red

LSOH Grey RAL7022

green

blue

LSOH Light Grey RAL7037

white

violet

orange

grey

yellow

brown

19

pink

aqua

14
2

15

16

10

21
20

PE Black RAL9005

Color

23

22

black

13

11

12

black

aqua

17

+70C
+55C

-15C

TRANSPORT

OPERATION

INSTALLATION

temperature [C]

1-12

-40C

18

-100

*For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
**In case of lower fiber count some tubes can be replaced by fillers.

SM G.652D RAL 1021

SM G657 A1, A2, A3


RAL 9010

MM 50/1025 OM2
RAL9018

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

telecom duct DDC-C0 | 57

telecom ductddc ci

TELECOM DUCT DDC CI


1

Cable structure
1. PE Outer Sheath
2. Fiberglass Yarns
3. PE Inner Sheath
4. Water blocking
Yarns
5. Central Strength
Member (FRP)

6. Loose Tubes (PBT)


with colored fibers
in filling gel
7. Fillers
8. Ripcords

4
5

Rodent
Protection High

Telecom

Duct

Hi-crush

Direct buried

Configuration
Applications

telecom duct DDC-ci


Total
elements

Active
tubes

5%
[mm]

Nominal
weight

Version

Fibers

Fibers
per
tube

1T x 6F

11.7

92

2T x 6F

12

11.7

93

4T x 6F

24

11.7

95

1T x 12F

12

12

11.8

97

2T x 12F

24

12

11.8

98

3T x 12F

36

12

11.8

99

4T x 12F

48

12

11.8

101

6T x 12F

72

12

11.8

103

10%
[kg/km]

Max. tensile
load [N]
installation

4400

operation

Crush
[N/10cm]

For installation into existing duct or directly


buried.

Good resistance to traction and compression

Fully dielectric cable

Rodent Retardant cable

2600

Features
4100

2000

4000

FRP strength and anti-buckling element

Optical fibers

Loose tube jelly filled (PBT 2.0mm)

Dry yarns to prevent moisture into the cable

8T x 12F

96

12

13,0

126

4200

2100

Fibreglass yarns as tensile elements

12T x 12F

144

12

12

12

15,5

178

4900

2200

Double PE Sheath

24T x 12F

288

12

24

24

17.9

229

4000

1900

Other Fiber counts available on demand

Operating temperature
+100

Available colors
3

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

10

11

12

Code
Color

t-telecom - Loose tube in cable (according to IEC 60304) - Fibers


Tube

-40C

-100

Code
Color

-15C

red

green

blue

white

violet

orange

grey

yellow

brown

**For the cable with a multi-layer construction color of the tubes will be repeated in second layer.
***In case of lower fiber count some tubes can be replaced by fillers.

58 | telecom duct DDC-ci

pink

black

aqua

TRANSPORT

OPERATION

temperature [C]

1-12

INSTALLATION

+70C
+55C

T-Telecom (according to IEC 60304) - Fibers

Telecom
Aerial

telecom aerialAero-DF03

TELECOM AERIAL Aero-DF03


1

Cable structure
2

1. PE Sheath
2. Ripcord
3. Water blocking Yarns
4. Loose Tube (PBT)
with colored fibers in filling gel
5. FRP Reinforcement Strength Member

Aerial

Telecom

FTTH

Cable variants
Applications

AERO-DF03
Variant

AERO DF 03

AERO DF 03

For installation on poles or walls

1-12

16-24

Can be installed in pipelines

8,3 x 4.6 (3%)

8,7 x 5,0 (-3%)

Fully dielectric cable

37

38

1300

1300

Fiber count
Cable dimensions [mm]
Cable weight [kg/km]
Max. installation tension [N]
Crush [N]

Features

5000

Loose tube jelly filled (PBT)

Up to 24 fibers in a cable

Two FRP strength elements

Dry yarns to prevent moisture into cable

Ripcord Yarns For easy sheath removal

PE UV resistant Sheath

Operating temperature
+100

span: 120m

-10C

TRANSPORT

NESC Light

OPERATION

APPLICATION AND CABLE SPAN CHARACTERISTIC

+50C
INSTALLATION

temperature [C]

+70C

-40C

sag: 2.4m

24

13
1

23

NSC Medium

16

21

17
20

LSOH Grey RAL7022

15

22

span: 70m
PE Black RAL9005

-100

14
2

19

18

LSOH Light Grey RAL7037

sag: 1.4m

NESC Heavy
span: 40m

SM G.652D RAL 1021

SM G657 A1, A2, A3


MM 50/1025 OM2
sag: 0.8m
RAL 9010
RAL9018

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

telecom AERIAL Aero-DF03 | 60

telecom aerialAero-AS02 2.0mm

TELECOM AERIAL Aero-AS02 2.0mm


1

Cable structure
1. PE Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel
Aerial

Telecom

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

3
4
7

FTTH

Configuration
Applications

AERO-AS02 PBT 2.0mm


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

Crush
[N/10cm]

For installation on poles or in ducts

High resistance to traction and compression

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

1T x 12F

12

12

10,0

71

2080

980

2T x 12F

24

12

10,0

72

2080

980

3T x 12F

36

12

10,0

74

2100

890

4T x 12F

48

12

10,0

75

2060

890

6T x 12F

72

12

10,0

77

2060

890

8T x 12F

96

12

11,3

96

2100

1100

FRP strength and anti-buckling element 2,1mm

12T x 12F

144

12

12

12

13,8

142

2050

1040

Optical fibers

Loose tube jelly filled (PBT 2.0mm)

6-12 elements SZ stranded cable core

Dry yarns to prevent moisture into cable

Aramid yarns as tensile elements

PE Outer Sheath

2000

Features

Other Fiber counts available on demand

Operating temperature
+100

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+70C

sag: 1.8m

24

13
1

23

span: 65m
LSOH Grey RAL7022

16

21
19

18

LSOH Light Grey RAL7037

NESC Heavy
span: 40m

SM G657 A1, A2, A3


MM 50/1025 OM2
sag: 0.8m RAL9018
RAL 9010

61 | telecom AERIAL AERO-AS02 2.0mm

MM 50/1025 OM3
RAL6027

-40C

17
20

sag: 1.3m

SM G.652D RAL 1021

-15C

15

22

NSC Medium

PE Black RAL9005

14
2

MM 50/1025 OM4
RAL4003

-100

TRANSPORT

+55C
OPERATION

span: 90m

INSTALLATION

temperature [C]

NESC Light

telecom aerialAero-AS03 2.0mm

Aerial

Telecom
Configuration

Cable structure
1. PE Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel

FTTH

TELECOM AERIAL Aero-AS03 2.0mm


1

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

3
4
7

AERO-AS03 PBT 2.0mm


Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Version

Fibers

Fibers
per
tube

1T x 12F

12

12

10,0

2T x 12F

24

10,0

Max. tensile load


[N]

Crush
[N/10cm]

installation

operation

73

3080

1800

76

3080

1800

For installation on poles or in ducts

High resistance to traction and compression

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

3T x 12F

36

12

10,0

77

3010

1400

4T x 12F

48

12

10,0

78

3010

1400

6T x 12F

72

12

10,0

79

3010

1400

8T x 12F

96

12

11,3

99

3100

1640

12T x 12F

144

12

12

12

13,8

145

3100

1640

Applications

2000

Other Fiber counts available on demand


Features

Available colors
T-Telecom (according to IEC 60304) - Fibers
3

10

11

12

Code
Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

t-telecom - Loose tube in cable (according to DIN) - Fibers


Tube

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code
Color

Optical fibers

Loose tube jelly filled (PBT 2.0mm)

6-12 elements SZ stranded cable core

Dry yarns to prevent moisture into cable

Aramid yarns as tensile elements

PE Outer Sheath

Operating temperature
+100

*In case of lower fiber count some tubes can be replaced by filler
NESC Light

sag: 3.8m

NSC Medium

temperature [C]

+70C
span: 190m

+55C
TRANSPORT

OPERATION

FRP strength and anti-buckling element 2,1mm

INSTALLATION

1-12

-15C
-40C

span: 130m

-100
sag: 2.6m

NESC Heavy
span: 75m

sag: 1.5m

telecom AERIAL Aero-AS03 2.0mm | 62

telecom aerialAero-AS03 2.5mm

TELECOM AERIAL Aero-AS03 2.5mm


1

Cable structure

Aerial

Telecom

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

1. PE Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel

3
4
7

FTTH

Configuration
Applications

AERO-AS03 PBT 2.5mm


Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

1T x 4F

11,4

88

1T x 6F

11,4

88

1T x 8F

11,4

88

1T x 10F

10

10

11,4

88

1T x 12F

12

12

11,4

89

2T x 12F

24

12

11,4

90

3T x 12F

36

12

11,4

91

48

12

11,4

installation

3200

operation

Crush
[N/10cm]

For installation on poles or in ducts

High resistance to traction and compression

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

Features

2200
3000

92

5T x 12F

60

12

11,4

93

6T x 12F

72

12

11,4

94

8T x 12F

96

12

13,0

122

3500

2700

12T x 12F

144

12

12

12

16,1

187

3400

2900

Other Fiber counts available on demand

FRP strength and anti-buckling element 2,5mm

Optical fibers

Loose tube jelly filled (PBT 2.5mm)

6-12 elements SZ stranded cable core

Dry yarns to prevent moisture into cable

Aramid yarns as tensile elements

PE Outer Sheath

Operating temperature

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

sag: 3.6m

temperature [C]

+70C
span: 180m

+55C

-15C
-40C

NSC Medium
span: 130m

-100
sag: 2.6m

NESC Heavy
span: 80m

sag: 1.6m

63 | telecom AERIAL Aero-AS03 2.5mm

TRANSPORT

4T x 12F

Max. tensile load


[N]

OPERATION

Fibers

Total
elements

INSTALLATION

Version

Fibers
per
tube

telecom aerialAero-AS04 2.0mm

TELECOM AERIAL Aero-AS04 2.0mm


1

Cable structure
1. PE Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel
Aerial

Telecom

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

3
4
7

FTTH

Configuration

AERO-AS04 PBT 2.0mm


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Applications
Max. tensile load
[N]
installation

operation

1T x 12F

12

12

10,2

75

4100

2090

2T x 6F

12

10,1

75

4100

2300

2T x 12F

24

12

10,2

76

4150

2120

4T x 6F

24

10,1

76

4150

2600

6T x 4F

24

10,1

76

4200

2800

3T x 12F

36

12

10,2

80

4200

2200

3T x 6F

36

10,1

76

4150

2600

4T x 12F

48

12

10,2

80

4200

2200

8T x 6F

48

11.3

97

4150

2600

6T x 12F

72

12

10,2

82

4200

2200

12T x 6F

72

12

12

13,8

142

4100

2600

8T x 12F

96

12

11,4

102

4200

2200

12T x 12F

144

12

12

12

13,9

151

4100

2200

Crush
[N/10cm]

For installation on poles or in ducts

High resistance to traction and compression

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

Features
2000

FRP strength and anti-buckling element 2,1mm

Optical fibers

Loose tube jelly filled (PBT 2.0mm)

6-12 elements SZ stranded cable core

Dry yarns to prevent moisture into cable

Aramid yarns as tensile elements

Operating temperature

Other Fiber counts available on demand


+100

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+70C

sag: 5.6m
24

13
1

23

NSC Medium

LSOH Grey RAL7022

TRANSPORT

-40C

15

16

21

17
20

PE Black RAL9005

-15C

14
2

22

span: 190m

+55C
OPERATION

span: 280m

INSTALLATION

temperature [C]

NSC Light

19

18

-100

LSOH Light Grey RAL7037

sag: 3.8m

NSC Heavy
span: 100m

SM G.652D RAL 1021

SM G657 A1, A2, A3 sag: 2mMM 50/1025 OM2


RAL 9010
RAL9018

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

telecom AERIAL AERO AS04 2.0mm | 64

telecom aerialAero-AS04 2.5mm

TELECOM AERIAL Aero-AS04 2.5mm


1

Cable structure

Aerial

Telecom

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

1. PE Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel

3
4
7

FTTH

Configuration
Applications

AERO-AS04 PBT 2.5mm


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

1T x 4F

11,4

90

1T x 6F

11,4

90

1T x 8F

11,4

90

1T x 10F

10

10

11,4

90

1T x 12F

12

12

11,4

91

2T x 12F

24

12

11,4

92

3T x 12F

36

12

11,4

93

4T x 12F

48

12

11,4

5T x 12F

60

12

6T x 12F

72

12

8T x 12F

96

12

12T x 12F

144

12

Max. tensile load


[N]
installation

Crush
[N/10cm]

operation

4100

For installation on poles or in ducts

High resistance to traction and compression

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

Features

2800

FRP strength and anti-buckling element 2,5mm

Optical fibers

94

Loose tube jelly filled (PBT 2.5mm)

11,4

95

6-12 elements SZ stranded cable core

11,4

96

Dry yarns to prevent moisture into cable

13,1

122

4400

3200

Aramid yarns as tensile elements

12

12

16,2

189

4800

4000

3000

Operating temperature

Other Fiber counts available on demand

+100

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+70C

sag: 5.2m

24

13
1

23

NSC Medium

PE Black RAL9005

LSOH Grey RAL7022

15

-40C
16

21

17
20

19

18

LSOH Light Grey RAL7037

sag: 3.8m

NESC Heavy
span: 110m

SM G.652D RAL 1021

SM G657 A1, A2, A3


MM 50/1025 OM2
sag: 2.2m RAL9018
RAL 9010

65 | telecom AERIAL AERO AS04 2.5mm

MM 50/1025 OM3
RAL6027

-15C

14
2

22

span: 190m

MM 50/1025 OM4
RAL4003

-100

TRANSPORT

+55C
OPERATION

span: 260m

INSTALLATION

temperature [C]

NESC Light

telecom aerialAero-AS06 2.0mm

TELECOM AERIAL Aero-AS06 2.0mm


1

Cable structure
1. PE Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel
Aerial

Telecom

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

3
4
7

FTTH

Configuration
Applications

AERO-AS06 PBT 2.0mm


Qnt
Version

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Fibers

Fibers
per
tube

Total
elements

1T x 4F

10,2

1T x 6F

Max. tensile load


[N]
installation

operation

79

6200

3600

10,2

79

6200

3600

1T x 8F

10,2

80

6100

3200

1T x 10F

10

10

10,2

80

6100

3200

1T x 12F

12

12

10,3

80

6100

3200

2T x 12F

24

12

10,3

82

6100

3200

3T x 12F

36

12

10,3

83

6100

3200

4T x 12F

48

12

10,3

84

6100

Crush
[N/10cm]

For installation on poles or in ducts

High resistance to traction and compression

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

Features

FRP strength and anti-buckling element 2,1mm

Optical fibers

Loose tube jelly filled (PBT 2.0mm)

3200

6-24 elements SZ stranded in 1-2 layers cable core

Dry yarns to prevent moisture into cable

Aramid yarns as tensile elements

PE Outer Sheath

5T x 12F

60

12

10,3

85

6100

3200

6T x 12F

72

12

10,2

87

6100

3200

8T x 12F

96

12

11,5

98

6050

3600

12T x 12F

144

12

12

12

14,0

145

6100

3200

2000

Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

NSC Medium

TRANSPORT

OPERATION

+55C
INSTALLATION

sag: 7.0m

temperature [C]

+70C
span: 350m

-15C
-40C

span: 240m

-100
sag: 4.8m

NESC Heavy
span: 130m

sag: 2.6m

telecom AERIAL Aero-AS06 2.0mm | 66

telecom aerialAero-AS06 2.5mm

TELECOM AERIAL Aero-AS06 2.5mm


1

Cable structure

Aerial

Telecom

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

1. PE Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel

3
4
7

FTTH

Configuration
Applications

AERO-AS06 PBT 2.5mm


Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

1T x 4F

11,5

94

1T x 6F

11,5

94

1T x 8F

11,5

94

1T x 10F

10

10

11,5

94

1T x 12F

12

12

11,5

95

2T x 12F

24

12

11,5

95

3T x 12F

36

12

11,5

96

4T x 12F

48

12

11,5

Max. tensile load


[N]
installation

6400

operation

Crush
[N/10cm]

For installation on poles or in ducts

High resistance to traction and compression

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

Features

2800

FRP strength and anti-buckling element 2,5mm

Optical fibers

97

Loose tube jelly filled (PBT 2.5mm)

6-24 elements SZ stranded in 1-2 layers cable core

Dry yarns to prevent moisture into cable

Aramid yarns as tensile elements

PE Outer Sheath

3000

5T x 12F

60

12

11,5

98

6T x 12F

72

12

11,5

99

8T x 12F

96

12

13,1

124

6050

4700

12T x 12F

144

12

12

12

16,2

190

6100

5000

Other Fiber counts available on demand

Operating temperature
+100

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+70C

sag: 7.0m

+55C

-15C
-40C

NSC Medium
span: 240m

-100
sag: 4.8m

NESC Heavy
span: 130m

sag: 2.6m

67 | telecom AERIAL Aero-AS06 2.5mm

TRANSPORT

span: 350m

temperature [C]

NESC Light

OPERATION

Fibers

Total
elements

INSTALLATION

Version

Fibers
per
tube

telecom aerialAero-AS09 2.0mm

TELECOM AERIAL Aero-AS09 2.0mm


1

Cable structure

Aerial

Telecom

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

1. PE Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel

3
4
7

FTTH

Configuration
Applications

AERO-AS09 PBT 2.0mm


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1T x 12F

12

12

10,4

90

9020

4600

2T x 6F

12

10,3

85

9080

5700

2T x 12F

24

12

10,4

92

6200

4600

Crush
[N/10cm]

For installation on poles or in ducts

High resistance to traction and compression

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

4T x 6F

24

10,3

87

9080

5700

3T x 12F

36

12

10,4

93

6100

4600

6T x 6F

36

10,3

89

9080

5700

FRP strength and anti-buckling element 2,1mm

4T x 12F

48

12

10,4

94

9020

4600

Optical fibers
Loose tube jelly filled (PBT 2.0mm )

Features
2000

8T x 6F

48

11,5

110

9080

5700

6T x 12F

72

12

10,4

97

9020

4600

6-12 elements SZ stranded cable core

8T x 12F

96

12

11,6

115

9140

4800

Dry yarns to prevent moisture into cable

12T x 12F

144

12

12

12

14,0

158

9800

5900

Aramid yarns as tensile elements

Other Fiber counts available on demand


Operating temperature
+100

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+70C

sag: 7.0m

24

13
1

23

NSC Medium

LSOH Grey RAL7022

TRANSPORT

-15C

15

22

span: 260m
PE Black RAL9005

14
2

+55C
OPERATION

temperature [C]

span: 350m

INSTALLATION

NESC Light

16

21

-40C

17
20

19

18

LSOH Light Grey RAL7037

-100

sag: 5.2m

NESC Heavy
span: 180m

SM G.652D RAL 1021

SM G657 A1, A2, A3


MM 50/1025 OM2
sag: 3.6m RAL9018
RAL 9010

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

telecom AERIAL AERO-AS09 2.0mm | 68

telecom aerialAero-AS09 2.5mm

TELECOM AERIAL Aero-AS09 2.5mm


1

Cable structure

Aerial

Telecom

FTTH

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

1. PE Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel

3
4
7

Configuration

AERO-AS09 PBT 2.5mm


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1T x 4F

11,5

98

9500

7500

1T x 6F

11,5

98

9500

7500

1T x 12F

12

12

11,5

98

9400

6600

2T x 6F

12

11,5

98

9500

7500

2T x 12F

24

12

11,5

99

9400

6600

4T x 6F

24

11,5

99

9500

7500

3T x 12F

36

12

11,5

100

9400

6600

Crush
[N/10cm]

Applications

For installation on poles or in ducts

High resistance to traction and compression

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

Features

2000

6T x 6F

36

11,5

100

9500

7500

FRP strength and anti-buckling element 2,5mm

4T x 12F

48

12

11,5

101

9400

6600

Optical fibers

Loose tube jelly filled (PBT 2.5mm )

6-12 elements SZ stranded cable core

Dry yarns to prevent moisture into cable

Aramid yarns as tensile elements

8T x 6F

48

13,2

127

9400

7700

5T x 12F

60

12

11,5

102

9400

6600

6T x 12F

72

12

11,5

103

9400

6600

8T x 12F

96

12

13,2

130

9200

7200

12T x 12F

144

12

12

12

16,3

201

9150

6600

Operating temperature

Other Fiber counts available on demand


+100

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+70C

sag: 7.0m

24

13
1

23

NSC Medium

LSOH Grey RAL7022

-40C

15

16

21

17
20

PE Black RAL9005

19

18

LSOH Light Grey RAL7037

sag: 5.2m

NESC Heavy
span: 180m

SM G.652D RAL 1021

SM G657 A1, A2, A3


MM 50/1025 OM2
sag: 3.6m
RAL 9010
RAL9018

69 | telecom AERIAL AERO-AS09 2.5mm

MM 50/1025 OM3
RAL6027

-15C

14
2

22

span: 260m

MM 50/1025 OM4
RAL4003

-100

TRANSPORT

+55C
OPERATION

span: 350m

INSTALLATION

temperature [C]

NESC Light

telecom aerialAero-AS12 2.5mm

TELECOM AERIAL Aero-AS12 2.5mm


1

Cable structure

Aerial

Telecom

FTTH

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

1. PE Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel

3
4
7

Configuration

AERO-AS12 PBT 2.5mm


Version

Fibers

Fibers
per
tube

Total
elements

Active
tubes

5%
[mm]

Nominal
weight
10%
[kg/km]

Max. tensile load


[N]
installation

operation

1T x 4F

11,6

101

12800

10100

1T x 6F

11,6

101

12200

9100

1T x 12F

12

12

11,6

101

12500

8700

2T x 6F

12

11,6

101

12200

9100

2T x 12F

24

12

11,6

103

12500

8700

4T x 6F

24

11,6

103

12200

9100

3T x 12F

36

12

11,6

106

12500

8700

Crush
[N/10cm]

Applications

For installation on poles or in ducts

High resistance to traction and compression

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

Features

2000

6T x 6F

36

11,6

104

12200

9100

FRP strength and anti-buckling element 2,5mm

4T x 12F

48

12

11,6

107

12500

8700

Optical fibers

Loose tube jelly filled (PBT 2.5mm)

6-12 elements SZ stranded cable core

Dry yarns to prevent moisture into cable

8T x 6F

48

13,3

134

12200

9100

5T x 12F

60

12

11,6

108

12500

8700

6T x 12F

72

12

11,6

110

12500

8700

Aramid yarns as tensile elements

PE Outer Sheath

8T x 12F

96

12

13,4

139

12500

8700

12T x 12F

144

12

12

12

16,3

205

12500

8700

Operating temperature

Other Fiber counts available on demand


APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

NSC Medium

TRANSPORT

OPERATION

+55C
INSTALLATION

sag: 14m

temperature [C]

+70C
span: 700m

-15C
-40C

span: 500m

-100
sag: 10m

NESC Heavy
span: 300m

sag: 6.0m

telecom AERIAL Aero-AS12 2.5mm | 70

telecom aerialAero-AS14 2.5mm

TELECOM AERIAL Aero-AS14 2.5mm


1

Cable structure

Aerial

Telecom

FTTH

5. Water blocking Yarns


6. Fillers
7. Waterblocking Tape
8. Ripcord

1. E Sheath
2. Aramid yarns
reinforcement
3. Central Strength
Member (FRP)
4. Loose Tubes (PBT)
with colored fibers in
filling gel

3
4
7

Configuration

AERO-AS14 PBT 2.5mm

5%
[mm]

Nominal
weight
10%
[kg/km]

11,6

102

Max. tensile load


[N]

Crush
[N/10cm]

Applications

For installation on poles or in ducts

High resistance to traction and compression

11100

Fully dielectric cable

Self-supported aerial cable with aramid reinforcements

UV resistant

installation

operation

14500

1T x 6F

11,6

103

14500

11100

1T x 12F

12

12

11,7

106

14200

9900

2T x 6F

12

11,6

103

14500

11100

2T x 12F

24

12

11,7

107

14200

9900

4T x 6F

24

11,6

104

14500

11100

3T x 12F

36

12

11,7

108

14200

9900

6T x 6F

36

11,6

104

14500

11100

4T x 12F

48

12

11,7

109

14200

9900

8T x 6F

48

13,4

137

14500

5T x 12F

60

12

11,7

110

6T x 12F

72

12

11,7

8T x 12F

96

12

12T x 12F

144

12

12

12

2000

Features

FRP strength and anti-buckling element 2,5mm

Optical fibers

Loose tube jelly filled (PBT 2.5mm)

11100

6-12 elements SZ stranded cable core

14200

9900

Dry yarns to prevent moisture into cable

111

14200

9900

Aramid yarns as tensile elements

13,4

139

14200

9900

16,3

206

14050

11500

Operating temperature

Other Fiber counts available on demand

+100

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+70C
temperature [C]

NESC Light
span: 550m

sag: 11.0m

24

13
1

23

NSC Medium

LSOH Grey RAL7022

15

-40C
16

21

17
20

PE Black RAL9005

19

18

LSOH Light Grey RAL7037

sag: 8.0m

NESC Heavy
span: 240m

SM G.652D RAL 1021

SM G657 A1, A2, A3


MM 50/1025 OM2
sag: 4.8m RAL9018
RAL 9010

71 | telecom AERIAL AERO-AS14 2.5mm

MM 50/1025 OM3
RAL6027

-15C

14
2

22

span: 400m

+55C

MM 50/1025 OM4
RAL4003

-100

TRANSPORT

Active
tubes

OPERATION

1T x 4F

Fibers

Total
elements

INSTALLATION

Version

Fibers
per
tube

Special
Cables

specialFTTA-DAC

SPECIAL FTTA-DAC
1

Cable structure
1. Outer Jacket PE
2. Fiber Glass Yarns
3. Loose Tube (PBT)
with colored fibers in filling gel
4. Ripcords
5. Embedded strength members (FRP)

FTTA

Hi-crush

Aerial

Compact design

Configuration
Applications

FTTA-DAC
Version

Fibers

Fibers per
tube

5%
[mm]

Nominal
weight
10% [kg/km]

1T x 2F

5.8

31

1T x 4F

5.8

31

Max. tensile load [N]


installation

1T x 6F

5.8

31

800
(e=0.33%)

1T x 8F

5.8

32

1T x 12F

12

12

5.8

32

1200
(e=0.50%)

1T x 24F

24

24

6.3

38

operation

Crush
[N/10cm]

250

Fiber to the antenna system ( FTTA)

Optical access cable with fiber glass yarns


reinforcement

Direct buried construction

Fully dielectric cable

Last mile connection

3500

Features

Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12

10

11

12

Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

red

green

blue

white

violet

orange

grey

yellow

brown

pink

natural

aqua

Fiberglass yarns as strength elements

Loose tube (PBT) with optical fibers

Jelly into the loose tube

Embedded strength members (FRP)

High resistant jacket of PE material, UV resistant

Code

Operating temperature
+100

Code

+70C

-15C
-45C

-100

73 | telecom AERIAL FTTA-DAC

TRANSPORT

OPERATION

+50C
INSTALLATION

temperature [C]

Color

specialBDC-CIP

SPECIAL BDC-CIP
Cable structure
1. PE Sheath
2. Fiberglass yarns
3. Loose Tubes (PBT)
with colored fibers in
filling gel
4. Water blocking Yarns
on FRP

11

5. Water blocking Tape


6. Central Strength Member (FRP)
7. 1,5mm2 Cu Insulated
Cooper Wire
8. Ripcord

22

5
6

Duct

FTTH

Rodent
Hybrid FO
Protection Basic + Power

Configuration
Applications

BDC-CIP
Optical
Fiber
Tubes

Copper
tubes

Max. tensile
load [N]

Fillers

5%
[mm]

Nominal
weight
10%
[kg/km]

installation

operation

Version

Fibers

Fibers
per
tube

2T x 12F
+4x1,5mm2

24

12

10,5

176

2700

11100

1T x 12F
+4x1,5mm2

12

12

10,5

176

2700

11500

Crush
[N/10cm]

For installation into existing duct


or directly buried

Good resistance to traction and compression

2700

Other Fiber counts available on demand


Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Features

FRP strength and anti-buckling element

Loose tube jelly filled (PBT 2.2mm)

Tubes with cooper core

Dry yarns to prevent moisture into the cable

UV stabilized PE Sheath

LSOH, PA etc Sheath option

Code

Operating temperature
+100

t-telecom - Loose tube in cable (according to IEC 60304) - Tubes

red

green

+70C

Code
Color

*In case of lower fiber count some tubes can be replaced by filler

+55C
TRANSPORT

OPERATION

temperature [C]

Tube

INSTALLATION

Color

-15C
-40C

24

13
1

23

14
2

16

21

17
20

PE Black RAL9005

SM G.652D RAL 1021

LSOH Grey RAL7022

SM G657 A1, A2, A3


RAL 9010

-100

15

22

19

18

LSOH Light Grey RAL7037

MM 50/1025 OM2
RAL9018

MM 50/1025 OM3
RAL6027

MM 50/1025 OM4
RAL4003

telecom AERIAL BDC-CIP | 74

FIBRAIN SP. Z O.O.


Rogonica 312
36-060 Gogw Maopolski
Poland
phone: (+48) 17 866-08-14
fax: (+48) 17 866-08-11
e-mail: info@brain.com

FIBRAIN MXICO
Paseo de la Reforma 250 / Piso 9
Esquina c/Niza, Col. Jurez
Del. Cuahtmoc
Mxico D.F. 06600
phone: (+52) 55 3600 7546
e-mail: info@brain.com.mx

Vous aimerez peut-être aussi