Boron is a natural element that is prevalent in ground water from areas with volcanic geology, present in all sea water
(3-5 mg/l) and is used in commercial products such as detergents. Mildly toxic to humans but frequently very toxic to
plants, especially to citrus varieties, boron is regulated in most regions of the world. The World Health Organization
(WHO) guideline for boron content in drinking water is 0.5 mg/l (ppm). Dow Water & Process
SolutionsAMBERLITE PWA10, a boron selective Ion Exchange (IX) resin that can help you to meet your drinking
water and irrigation water requirements.
Boron present in water is always in some form of boric acid, a very weak acid similar to silicic acid with a pK value of
9.1. At a pH lower than 7, boric acid is undissociated as H3BO3 or B(OH). Boric acid is a Lewis acid, i.e. an oxidane
acceptor rather than a deuteride donor:
At a pH higher than 11.5, boron occurs as dissociated borate [B(OH)4]. In concentrated solution, polymeric ions are
formed:
AMBERLITE PWA10 is used for selective boron removal in drinking water applications. This unique chelating resin
uses a carbohydrate as the active group. This figure shows the resin composition and the mechanism that chelates
boron.
Boron concentration and salt background have little effect on AMBERLITE PWA10 operating capacity or boron
leakage. The most important parameter affecting capacity is flow rate. These figures show the operating capacity and
the boron leakage under controlled laboratory conditions.
Regeneration
AMBERLITE PWA10, a weakly basic resin, regenerates in a two-step, co-flow manner. First, the borate is displaced
with hydrochloric (HCl) or sulphuric acid (H2SO4), then the resin is converted back to the free base form with sodium
hydroxide (NaOH). Regenerant levels are approximately stoichiometric: roughly 1 equivalent of acid per liter of resin,
or about 130% of total capacity, and 0.7 eq of sodium hydroxide. Because the regeneration procedure does not
depend on capacity and involves complete conversion of the active groups, the optimum service flow rate will be site
specific based on local conditions.
Displaceme
nt 1
Neutralizati
on
Displaceme
nt 2
Fina
l
Rins
e
DL Water
NaOH
DL Water
Water
3.55
3.5-5
N/A
2.5
N/A
N/A
Dose (g/l)
35
50
N/A
28
N/A
N/A
Volume
(BV)
Rate
(BV/h)
1.52
1.5-2
2-3
Ste
Regenerati
on
Solution
HCI
Concentrati
on (%)
H2SO