Vous êtes sur la page 1sur 102

318

PHOENIX CONTACT

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
Modular converters for MCR technology
The modular MCR converters for MCR
technology avoid the distortion of analog
signals caused by external disturbance
variables. With accurate conversion,
isolation, filtering or adaptation of analog
signals, they provide safe and increased
transmission quality, and thus the quality of
closed-loop control circuits.
This is reflected in the following product
segments:
MINI Analog
The modular, 6 mm wide system offers
state-of-the-art technology for the most
demanding requirements throughout the
signal conversion range.
MACX Analog / MCR Analog
Multifunctional devices with highprecision transmission performance:
Configurable via DIP switch or software
Universally applicable and hence reduced
storage costs
High level of availability
Digital displays for displaying analog
standard signals, frequencies, pulses and
times
Setpoint adjuster for the specification of
analog current or voltage values, with a
manual and automatic ramp function
PACT Analog
Space-saving current transformer range:
Depth of only 30 mm is uniformly used for
all transformer sizes
Flexible installation position is possible,
e.g. horizontal for branch exits
Up to 4000 A AC
3000 versions
Also available in a calibration-capable and
calibrated version

Program overview
Product overview

320

Basics

322

MINI Analog
Isolation
Temperature
Conversion
Control
Accessories

328
330
340
343
345
347

MACX Analog / MCR Analog


Isolation
Temperature
Conversion
Control
Power
Configuration software

356
358
370
378
380
390
389

Digital displays
Analog standard signals
Frequencies, pulses, times
Setpoint adjuster

383
385
386

PACT Analog
Current transformer (cannot be calibrated)
Current transformer (can be calibrated)
Accessories

400
403
413
419

Function Line (...-FL-...)


The multi-functional modules can be used
universally; they increase the system
availability and reduce storage costs.

Standard Line (...-SL-...)


The compact, space-saving and low-cost
modules are particularly suitable for serial
applications.
Install, connect, finished!

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

319

INTERFACE Analog
Product overview
MINI Analog

Product type

Product details

Isolation
3-way isolation amplifier

4-way signal duplicator


3-way repeater power supply
2-way passive isolator

Page
- Configurable
- Fixed signal combinations
- Configurable
- Power supplied to input loops

MINI MCR-SL-U...-...-UI
MINI MCR-SL-SHUNT-UI
MINI-MCR-SL-...-...
MINI-MCR-SL-UI-2I
MINI-MCR-SL-RPS...
MINI-MCR-SL-...CP-I-I

330
332
335
336
337
338

- Power supplied to output loops

Temperature
Temperature transducers

Page
Universal, active
Universal, passive
RTD (e.g. Pt 100), active
RTD (e.g. Pt 100), passive

MINI-MCR-SL-PT100-UI...
MINI-MCR-SL-PT100-LP

339
341

Thermocouples, active

MINI-MCR-SL-TC-UI

342

Conversion

Page

Frequency transducers
Potiposition transducers

MINI-MCR-SL-UI-F
MINI-MCR-SL-R-UI

Control
Threshold value switches

Isolating switching amplifiers


Setpoint adjusters

Digital display

343
344
Page

Temperature signals
Analog standard signals

MINI-MCR-SL-UI-REL

346

NAMUR sensors
Current, voltage
Setpoint potentiometer
Constant voltage source
Analog standard signals

MINI-MCR-SL-NAM-2RNO

345

Frequencies, pulses, times

Power
Current transducers

Universal, AC/DC currents


Alternating current, AC, active
Alternating current, AC, passive

Voltage transducers
Current transformers (cannot be calibrated)

Current transformers (can be calibrated)

Current protectors
DC voltage
AC voltage
Bus-bar transformers
Plug-in transformers
Winding transformers
Bus-bar transformers
Plug-in transformers

Accessories
Configuration
DIN rail adapters
System cabling

Bridging the supply voltage

Page
Configuration software
Cables
System components
1:1 feed-through terminal block

Adapters, cables
MINI-MCR-SL-TB

350
347

System components

Power terminal, system power supply unit,


DIN rail connectors

348

Transparent cover, insert strips,


Zack marker strip for flat-ribbon labeling

347

Marking material
Mounting material

320

PHOENIX CONTACT

Current transformers

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
Product overview
MACX Analog / MCR Analog

Digital displays

PACT Analog

Page
MACX MCR-UI-UI...
MCR-C-UI-UI...-DCI
MCR-C-...-DC
MCR-FL-C-UI-2UI-DCI
MACX MCR-SL-RPSSI-I...
MCR-SL-1CLP-I-I-00-4KV
MCR-...CLP-I-I-00
MCR-CLP-UI-I-4

358
360
364
362
365
368
369
367
Page

MCR-T-UI-...
MCR-FL-T-LP-I
MCR-FL-HT-T-I
MCR-PT100-...(-DC)
MCR-SL-PT100-LP-I
MCR-SL-HT-PT100-I

370
374
376
372
375
377

Page
MCR-F-UI-DC

378

Page
MCR-T-UI-...
MCR-SL-PT100-SP
MCR-PSP-DC
MCR-2SP-UI-DC

370
373
380
381

EMG 30-SP-...LIN
MCR-PS-24DC-10DC

387
388

Page

MCR-FL-D-U-I-2SP-...

383

MCR-SL-D-SPA-UI

386

MCR-FL-D-U-I-2SP-...
MCR-SL-D-U-I
MCR-SL-D-FIT

383
384
385

Page
MCR-S-1-5-UI-...-DCI
MCR-S-10-50-UI-...-DCI
MACX MCR-SL-CAC-5-I-...
MCR-SL-S-...00-U
MCR-SL-S-...00-I-LP
MCR-SLP-1-5-UI-0
MCR-SL-S-16-SP-24
MCR-VDC-UI-B-DC
MCR-VAC-UI-0-DC

Page

390
391
393
394
395
396
397
398
399
PACT MCR-V1-...
PACT MCR-V2-...
PACT MCR-V3-...
PACT MCR-V1C-...
PACT MCR-V2C-...
Page

MCR/PI-CONF-WIN
Adapter, cable

Page

Page

389
389
MCR-SL-D-RA

DIN rail connectors

403
404
412
413
414

387

PACT MCR-RA

419

Copper sleeves, secondary terminal cover,


insulating caps

419

348

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

321

INTERFACE Analog
Basics - technical data

Input
Maximum input signal
The maximum input signal describes the
value at which no damage to the module
and the signal generator has occurred yet. If
these values are exceeded, suppressor
diodes, which short circuit this input when
a surge voltage is detected, can be triggered.
The transmission range of the analog signals
is only located within the given input ranges.
Input resistance
The input resistance of an isolation
amplifier or measuring transducer is
designed such that the input signal is loaded
only slightly. This yields a low-resistance
input for current inputs and a highresistance input for voltage inputs.
Voltage drop
In case of passive isolators, the input
voltage drop occurs as a result of the
voltage drop of the operational load and the
auxiliary power requirements of the
module. The more the auxiliary power
requirements of the passive isolator, the
smaller the operational output load may be.
Low auxiliary power requirements are the
measure of the quality of a device.
Common mode rejection
In case of isolation amplifiers, operational
amplifiers are used internally for
transmission. Theoretically, operational
amplifiers have an ideal transmission and
amplification behavior. In practice, however,
things are different. When both input
voltages are changed in the same direction,
i.e. exactly the same voltage to ground is
applied to both input terminal blocks, this
leads to an unintended output signal.
Theoretically, no output signal should
appear with an ideal operational amplifier,
since the differential input signal is "0 V".
The common mode rejection indicates the
factor (in dB) by which the common input
voltage at both inputs is amplified less than
the difference in voltage between the two
inputs.

322

PHOENIX CONTACT

(True) r.m.s. value


According to the definition, the r.m.s.
value of an alternating current has the same
magnitude as a direct current that develops
the same heat energy and has the same
force effects on other conductors carrying
a current.
Many measuring transducers measure the
rectified mean value which is then adapted
to the r.m.s. value. However, this measuring
technique is precise only with sinusoidal
signals. If distorted and higher frequency
and mixed signals can be measured
accurately, this is known as true r.m.s.
measurement.

Binary output

Analog output

Transistor
A PNP transistor switching output
transmits 24 V DC switching signals from up
to approximately 100 mA.

Maximum output signal


If the devices operate without
disturbances, an override at the input
cannot cause greater values at the output.
Zero/span adjustment
When the zero point is set, the zero point
of an analog output is adjusted and set in
relation to the input signal.
When the "amplification" span is set, the
analog output is adjusted in relation to the
input signal. In this case, the output
characteristic curve is increased or
decreased by an amplification factor.
Load
The load on the output side indicates the
load-carrying capacity of a measuring
transducer or an isolation amplifier. Current
outputs can generally drive a maximum of
500 ; voltage outputs can be loaded with
a minimum of up to 10 k..
Residual ripple / ripple
A superposed ripple can appear on the
output signal due to signal conditioning
required by the circuit. The residual ripple is
given in mVPP or mVrms.
Open circuit response
With some measuring transducers, the
input signal is permanently monitored for
possible open circuits in the signal cable. If
the signal exceeds or falls below a tolerance
limit, an open circuit is detected and a
defined output signal is sent. With
programmable devices, the output signal
can be freely selected.

Relay
Numerous products with a relay output
that are shown in the catalog are made with
hard-gold-plated relay contact material. The
voltage range is important when utilizing
this contact material. When voltage ranges
up to 30 V AC/ 36 V DC are used, up to
50 mA can be transmitted. Even very small
currents are transmitted perfectly. If the
previously mentioned voltage range is
exceeded and values of 250 V AC/DC are
processed, currents of up to 2 A can flow.
The subsequent transmission of small
currents, however, can then no longer be
guaranteed.

General data
Supply voltage
In the product range, DC and AC power
supply units are offered depending on the
item. A 24 V DC version is available as a
standard power supply unit that works in
the voltage range of 20...30 V DC. The
different supply voltages can be found in the
technical data.
Current consumption
The value given here describes the
auxiliary power requirements of the
devices. In addition, there are the output
current and the load of the switching
output, if any.
Transmission error
The transmission precision is a gauge of
the quality of a measuring transducer. It is
the deviation from the ideal transmission
characteristic curve and includes linearity,
span, and offset errors.
Non-linearity
Non-linearity is the deviation from the
ideal transmission precision without span
and offset errors.
The non-linearity of a signal makes it
possible to evaluate the course from zero
to span. Normally, the linearity errors that
are given indicate a deviation from the ideal
transmission characteristic curve as a
percentage.

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
Basics - technical data
Temperature coefficient
The temperature coefficient evaluates the
deviating precision if the ambient
temperature around an isolation amplifier
or measuring transducer changes. In most
cases this data is given as a percentage. An
alternative definition is ppm/K (parts per
million/Kelvin). Example: 250 ppm/K
correspond to 0.025%/K.
Limit frequency
Isolating amplifiers are basically designed
to transmit DC signals. Signal changes,
though, require a dynamic behavior that is
determined by the limit frequency and
therefore offer the possibility of
transmitting small AC quantities (normally:
30 Hz) as well. At the same time, a low limit
frequency suppresses higher-frequency AC
components.
Step response
The step response indicates the response
time of the output signal when an input
signal step occurs (10...90%). The step
response is inversely proportional to the
limit frequency. This means that the
response time decreases when the limit
frequency increases.
Test voltage
The test voltage defines the dielectric
strength of an isolated distance and is
determined by type tests. In this test, a
50 Hz voltage is applied for one minute, and
it describes a value at which no disruptive
electrical charge to another potential level
takes place in the device.
Safe isolation
"Safe isolation" is defined as protection
from currents dangerous to the human
body. When modules are specified in
accordance with EN 61010, one
distinguishes between faultless and
disturbed operation. With faultless
operation, nominal supply voltages of
30 V AC/ 60 V DC are valid.

Ambient temperature range


The temperature limits given here are
only for operation. These limits do not
apply to storage and transport. The
temperature limits of the materials used are
decisive for those cases. If the devices
should be outside of the given temperature
range during assembly, they must be
brought back to the given temperature
range first before the system startup. It is
important to make sure that no
condensation occurs.

Protective circuit
In order to protect the MCR modules
against surge voltage, suppressor diodes are
connected upstream of the signal and supply
paths. These diodes behave in a similar
manner to conventional Zener diodes. In
contrast, the suppressor diode has faster
response times and a higher maximum
current.

Information regarding directives and


standards
When non-independent items (components) are further processed, the
applicable specifications for installation must be observed.

For installation in devices, the specifications of the respective device also


apply. (Standards that are applicable at the time of printing the catalog)

Directives

EU

International

Electromagnetic Compatibility Directive (EMC)

2004/108/EC

Low-voltage directive (LVD)

2006/95/EC

Ex directive (ATEX)

94/9/EC

Electronic equipment for use in electrical power installations and their assembly into
electrical power installations

EN 50178:1997

Safety regulations for electrical measurement, control and laboratory equipment


Part 1: General requirements

EN 61010-1:2001

IEC 61010-1:2004

Programmable logic controllers Part 2: Equipment requirements and tests

EN 61131-2:2007

IEC 61131-2:2007

EMC - Part 6-2: Generic standards - noise immunity for industrial sectors

EN 61000-6-2:2005

IEC 61000-6-2:2005

EMC - Part 6-4: Generic standards - noise emission for industrial sectors

EN 61000-6-4:2007

IEC 61000-6-4:2006

Electrical equipment for measurement systems, control systems and laboratory use
EMC requirements

EN 61326-1:2006

IEC 61326-1:2005

Electrical operating equipment for potentially gas-explosive areas Part 0: General requirements

EN 60079-0:2006

IEC 60079-0:2007

Explosive atmosphere Part 11: Device protection through intrinsic safety "i"

EN 60079-11:2007

IEC 60079-11:2006

Electrical operating equipment for potentially gas-explosive areas Part 15: construction, testing and labeling of electrical equipment of the protection type "n" EN 60079-15:2005

IEC 60079-15:2005

Product standards

EMC

ATEX

Environmental tests
Environmental factors Part 2-1: Test method - test A: cold

EN 60068-2-1:2007

IEC 60068-2-1:2007

Environmental factors Part 2-2: Test method - test B: heat

EN 60068-2-2:2007

IEC 60068-2-2:2007

Environmental factors Part 2-6: Test method - test Fc: waves (sinusoidal)

EN 60068-2-6:2008

IEC 60068-2-6:2008

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

323

INTERFACE Analog
Basics - isolation

Active isolation
3-way isolation
Input signal

Input isolation
IN

OUT

Output
signal

Input signal

Repeater power supply


IN

OUT

Output
signal

POWER

POWER

In the case of modules with this isolation


system, all components that are connected
to the input, output, or supply are
protected from each other against
interferences. All three directions (input,
output, and supply) are correspondingly
electrically isolated from one another.
The 3-way isolation provides electrical
isolation between the measurement sensor
and the controller as well as between the
controller and actuator.
On the input side, the modules need
active signals. On the output side, they
provide a filtered and amplified signal.

OUT

Output
signal

In the case of modules with this isolation


system, the electronics connected on the
output side (e.g. the controller) are to be
protected from interferences from the field.
For this reason, only the input is electrically
isolated from the output and the supply,
which lie on the same potential.
On the input side, the modules need
active signals (e.g. from measurement
sensors). On the output side, they provide
a filtered and amplified signal e.g. from the
controller.

Repeater power supplies use the signalinput side not only for measured value
acquisition, but also to provide the
necessary power to the passive looppowered measurement sensors connected
on the input side.
On the output side, they provide a
filtered and amplified signal e.g. from the
controller.
The isolation method of these modules is
that of input isolation.

Applications

Passive isolation, supplied on the


input side

Input signal

IN

POWER

Passive isolation

Feed-in using
signal

Feeding the
measuring transducer
Input signal

IN
OUT

Passive isolation, supplied from the


output side (loop-powered)

Output
signal

Input signal

The modules obtain the power required


for signal transmission and electrical
isolation from the active input circuit. A
conditioned current signal for the
controller or for actuators is available on
the output side.
This passive isolation allows signal
conditioning (interrupting of ground loops)
and filtering without an additional power
supply.

Problem: Disruptive radiation

Feed-in using
signal

IN
OUT

RE

Output
signal

The modules obtain the power needed


for signal transmission and electrical
isolation from the active output circuit,
ideally from a PLC input card that supplies
power.
On the output side, the loop-powered
modules work with a 4...20 mA standard
signal. On the input side, the passive
isolator processes active signals.
When this isolation technique is used, it is
important to make sure that the active
signal source connected on the output side
(e.g. an active PLC input card) is able to
supply power to the passive isolator as well
as to operate its load.

Solution:

I
RE

Problem: Voltage difference in the ground potential

RE

PGround 1

Ground current loop P


Ground 2

Solution:

RE

PGround 1

324

PHOENIX CONTACT

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

No ground current
loop

PGround 2

INTERFACE Analog
Basics - temperature

Resistance thermometers
Resistance thermometer:
Resistance change as a function of the temperature

Two-wire connection method


The resistance
i
R
thermometer is connected
to the MCR measuring
R
transducer using a two-wire
conductor. Please note that the cable
resistances are added to the measured
resistance and consequently distort the
result.
A distance of 10 m should not be
exceeded.
L2

Pt 1000

1000

Pt 100
100
800

600

700

400

500

200

300

100

-200

Pt 10
-100

Resistance []

L1

10000

Temperature [C]

Resistance thermometers (e.g. Pt100, Ni


1000) change their resistance value
depending on the temperature. The MCR
temperature transducers detect this change
and convert it to a proportional analog
signal.
To avoid unwanted self-heating of the
sensor, the constant measured current used
is kept as low as possible
(MCR-T-UI... 250 A).

Example: A 50 m long copper cable with a cross-section of 0.5 mm2 has


a specific resistance of 3.4 . A Pt 100 sensor has a resistance change of
0.384 per 1 K temperature change. This corresponds to an error of
8.8C.

Three-wire connection method


A three-wire system is
i
R
normally used in order to
minimize the influence of the
R
cable resistances. An
R
additional conductor is
connected to the resistance thermometer,
so that the latter is measured using two
measurement circuits, one of which acts as
a reference. The cable resistance is thus
compensated.
L1

L2

L3

Identical cable lengths and an identical


ambient temperature are essential here.
Since this is more or less the case in the
majority of applications, the threeconductor system is the one most
commonly encountered today. Conductor
alignment is not necessary.

Four-wire connection method


The four-wire connection method is an
ideal connection method for resistance
thermometers.
The measurement result is affected
neither by cable resistances nor by their
temperature-dependent fluctuations. The
voltage drop on the supply and return lines
can thus be measured and compensated for
separately. Conductor alignment is not
necessary.

Thermocouples

80

Typ E
Typ J

60

Typ K
Typ N

40
Typ R

Typ T

20

Typ S
Typ B

1600

1800

1200

1400

800

1000

400

600

200

0
-200

Thermocouple voltage [mV]

Thermocouples:
Thermocouple voltage change as a function of temperature

Temperature [C]

In contrast to the resistance


thermometers, thermocouples are active
sources that generate a voltage in the mV
range. The temperature difference
measured between the measurement
junction and the cold junction is converted
to an absolute temperature with the help of
cold junction compensation.
Functional principle:
If different metals are joined together, a
thermal voltage is produced at the metal
atoms as a result of the different binding
energies of the electrons. This voltage is
dependent firstly on the metals themselves
and secondly on the temperature.

If the same temperature


Fe
Cu
prevails at the measuring
junction (1) and the cold
Cu
CuNi
junction (2), no current will
flow because the generated
partial voltages cancel each other out.
However, if the temperatures at the
measuring junction and the cold junction
are different, different voltages are
produced. These voltages do not
completely cancel each other out, and thus
current flows.
A thermocouple thus always measures
only a temperature difference. This is
derived from the difference between the
thermal voltages at the measuring junction
and at the cold junction.
The voltage produced by the
thermoelectric effect is very low, only a few
microvolts per Kelvin.

Only the difference between the thermal


voltages of constantan (Cu-Ni) and iron is
therefore relevant.
A role is also played by the temperature
at the terminal point. If it is known, the
temperature at the measuring junction can
be derived by adding the thermal voltage
measured at the same junction.
The MCR temperature transducers for
thermocouples therefore detect the
temperature at the terminal points and
compensate this value, which is also
referred to as the cold junction.
This process is sometimes called cold
junction compensation.

Example: If a thermocouple type J (FE-CuNi) is connected to a copper


terminal, thermal voltages with opposite signs will be generated (at the
iron-copper and copper-constantan transitions) and cancel each other out.

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

325

INTERFACE Analog
Basics - power

Current measurement
If purely ohmic loads (incandescent lamps,
heaters etc.) are operated in a conventional
230 V power system, no distortions are
produced on this system.
As non-linear loads increase as a result of
phase angle-controlled regulation

components, pure sine waves gradually take


on a trapezoidal curve shape.
The majority of current and voltage
transducers are calibrated for sinusoidal
alternating currents, so that they can only
indicate the r.m.s. value of an alternating

current by mean-value generation.


True r.m.s. measuring transducers are
independent of specific form factors and will
accept any curve shape.

Measurement of root mean square (r.m.s.)


values according to the transformer principle

True r.m.s. (TRMS) measurement


according to the Rogowski principle

True r.m.s. (TRMS) measurement


using a Hall sensor

Analog
out

According to Faraday's law of induction, a


magnetic flux which changes over the
course of time produces an induced voltage
at the terminals of a coil. A circuit
arrangement consisting of two electrically
isolated but magnetically coupled circuits is
known as a transformer. This method of
current transfer is one of the simplest and
most commonly used methods.

The Rogowski principle is a special


method used to measure sinusoidal and
non-sinusoidal alternating currents in a
transformer. This non-ferrous induction coil
(air-core coil), known as the Rogowski coil,
measures the magnetic voltage along a
closed circumference around a currentconducting wire.
The output signal of the Rogowski coil is
then conditioned so that an exact replica of
the primary current is obtained.

The magnetic flux generated by the


primary current IP is condensed in the
magnetic circuit and measured in the air gap
using a Hall sensor. The output signal of the
Hall sensor is then conditioned so that an
exact replica of the primary current is
obtained.

Mean-value generation
True r.m.s. value
(r.m.s. value)
The r.m.s. value of an AC current
corresponds to the steady-state value that
results from the instantaneous values of this
current. This steady-state value generates
the same thermal work in an ohmic resistor
as a DC current of identical magnitude.
The term "true r.m.s. value" simply means
that distorted, direct and pulsating currents
may also be measured. The measuring
transducer is independent of the curve
shape.
For a sinusoidal AC current this means:
I
US
Irm = S
Ur =
2
2

326

PHOENIX CONTACT

Arithmetic average value


The arithmetic average value serves to
measure DC currents or filter a DC portion
from a pulsating current. Using the
arithmetic average value on a symmetrical
AC current would result in a measured
value with the value "0".
The arithmetic average value makes it
possible to make DC currents available as
standard analog signals at the output. The
polarity can be evaluated by means of a
bipolar output signal.

IS
Irms

Iaverage

For the 230 V/50 Hz power system, this


means the following for the voltage levels:
Urms = 230 V
US

= 325 V

Uaverage =

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

0V

INTERFACE Analog
Basics - control

Digital displays

Parameterization of the
characteristic curve with base points
With non-linear input signals, the
received analog values can be assigned to
the value to be displayed by means of a
programmable characteristic curve. This
curve can consist of up to 24 base points.
Flow sensors with a non-linear
characteristic curve can be adapted in this
way, for instance. The analog signal digital
displays in the Function Line additionally
feature a summing function which, to take
an application example from bottling
technology, switches over from the
instantaneous value (= flow rate in l/min) to

the total flow integrated in the background,


and displays this in any unit of measurement
on the display at the touch of a key. This
saves space and money because there is no
need for a second digital display.
Limit values too can be called up simply by
pressing a key. Limit values 1 and 2 can be
assigned to either the actual value or the
cumulative value. If the latter value is
exceeded, one of the two output relays is
energized.
Other applications include indicating
liquid levels, pressures and temperatures.
With servo motors, the analog output
signals (0...10 V) generated by the
tachogenerator can be supplied to the input
of the digital display in order to indicate the
motor speed.

Application 1:
Pressure measurement and display on MCR-SL-DUI

4...20 mA

bar

Table:

Analog signal

Base point 1

4 mA

15 bar

Base point 2

20 mA

30 bar

Display value

Characteristic curve:

Measured value

Use of the freely programmable


characteristic curve
The freely programmable characteristic
curve, i.e. the assignment of the displayed
value to the input value, is important in
process applications for indicating flow
rates or liquid levels.
The purpose of level measurements is
very often not to determine how much
liquid is still inside the tank, but rather to
establish how much has been drawn out of
it. In this case, the characteristic curve can
simply be inverted in order to display the
required value.

Base point 2

Base point 1
Pressure

Application 2:
Pressure measurement and display on MCR-FL-D-U-I...

Pr1

Pr2

L
min
P

Flow meter
24 V

0...20 mA

Mains voltage

Switching behavior of relay or


transistor outputs:
A different switching behavior can be
defined for each relay or each transistor
when it reaches a preset switching point.
All the possible settings for the switching
behavior are shown and explained in the list:
The first two options include a hysteresis,
i.e. the behavior of the relay depends on
the direction from which a switching point
is reached
For the remaining options, with the
exception of the last two ("on" and "off"),
a switching tolerance is taken into account
to prevent the relay contact from
"chattering". The relay is not switched
until the switching point plus switching
tolerance has been reached

In the "on" state, the relay is permanently


picked up. It only responds if there is an
open circuit and if it has been set to drop
in this event
In the "off" state, the relay only responds if
there is an open circuit and it has been set
to pick up in this event

Possible settings for the switching behavior


Relay picks up when the value is below SPL,
hysteresis active
Relay picks up when SPH is exceeded,
hysteresis active
Relay picks up when value is below SPL
Relay picks up when SPL is exceeded
Relay picks up when value is below SPH
Relay picks up when SPH is exceeded
Relay picks up between SPL and SPH
Relay picks up outside SPL and SPH
Relay is permanently dropped
Relay is permanently picked up
SPL = Set Point Low (low switching point)
SPH = Set Point High (high switching point)

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

327

INTERFACE Analog
MINI Analog

MINI Analog - Saves space in your control cabinet

328

PHOENIX CONTACT

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MINI Analog

Conversion

Temperature

Isolation

State-of-the-art technology for highest


requirements
The unit with a design width of only
6.2 mm makes it possible to isolate signals
electrically, convert signals, record
temperatures or switch threshold values.
The MINI Analog range by Phoenix
Contact offers these and various other
functions.

Isolation:
Configurable and standard 3-way
isolation amplifiers
Configurable signal duplicators
Repeater power supplies
Passive isolators

Power bridging
The bridging from below via DIN rail
connectors allows replacement of
individual devices without disturbing the
group

Temperature:
Configurable temperature
transducers for Pt 100
Configurable loop-powered
temperature transducers for Pt 100
Configurable temperature
transducers for type J and K
thermocouples

Conversion:
Configurable analog frequency
transducers
Configurable potiposition
transducers

Features
In addition to the extensive range, MINI
Analog offers a wide spectrum of features
that provide direct operational advantages.
In many applications, the analog signal
transmission on 6 mm comprises a large
number of channels in a small space. Errorfree, time-efficient and cost-saving wiring
solutions therefore have utmost
significance in this regard.
In addition to an intelligent supply concept
using a DIN rail connector, the system cabling
ensures the lowest wiring cost.
DIP switches that can be accessed from
the sides allow a simple and quick
configuration of modules without
complicated software parameterization.

Power bridging

Operational reliability

Operational reliability
3-way isolation increases the operational
reliability in face of disturbances in the
system
Approvals
An extensive approval package allows
problem-free usage in different fields. For
example, the ATEX approval in
accordance with the "n" protection type
allows the modules to be used in the Ex
zone 2 (gas atmosphere).

System cabling

System cabling
Time-saving system wiring with the MINI
analog system adapter
Low current consumption
This results in minimum self-heating and
maximum service life.

Low current consumption

Connection method
Clear wiring thanks to eight connections,
with a choice of screw or spring-cage
terminal blocks.

Control

Labeling
Labeling options using Zack marker strips
and/or cover with inserted label.
Control:
Configurable NAMUR switching
amplifiers
Configurable threshold value
switches

Configuration
Modules can either be ordered preconfigured or can be configured using the
DIP switches.

Connection method

Labeling

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

329

INTERFACE Analog
MINI Analog
Configurable 3-way isolation
amplifiers
6,2

Isolation

102,5

93,1

IN

U,I

U,I

OUT

MINI MCR-SL-UI-UI
SL

POWER

Configurable 3-way isolation amplifiers

uF

Ex: X U

Housing width 6.2

Configurable input and output signals


3-way isolation
Low power consumption
Power supply possible through the foot
element (T-Connector)

IN UI 1
GND1 2

I,U
U

U,I

5 OUT UI
6 GND2

DC DC

solid

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Screw
M3

DC

7 UB +
8 GND3

UB + 3
GND3 4
ME 6,2 TBUS-...

The MINI MCR-SL-UI-UI three-way


isolation amplifiers are used for electrical
isolation, conversion, amplification and
filtering of standard signals.
The devices that can be adjusted via DIP
switches are electrically isolated from each
other in the input, output and supply circuit.
A new type of connection concept makes
the devices very low-loss with regard to
their power consumption. This is expressed
in low self-heating and has a significant
influence on the service life.
Thanks to the possibility of power
bridging via the foot element, the devices
can be connected to the power supply both
simply and quickly.
The desired input and output signal
combination must be specified when
ordering pre-configured modules (refer to
the order key). If specification details are
incorrect or missing, the devices will be
supplied with the standard configuration
(input signal 0...10 V, output signal
0...20 mA).
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

Description

Type

Order No.

MCR 3-way isolation amplifier, for electrical isolation of analog


signals,
Order configuration
Screw connection
Order configuration
Spring-cage conn.
Standard configuration
Screw connection
Standard configuration
Spring-cage conn.

MINI MCR-SL-UI-UI
MINI MCR-SL-UI-UI-SP
MINI MCR-SL-UI-UI-NC
MINI MCR-SL-UI-UI-SP-NC

2864383
2864710
2864150
2864163

Technical data
Input data
Input signal
Input resistance
Output data
Output signal
Maximum output signal
No-load voltage
Short-circuit current
Load RB
Ripple
General data
Supply voltage UB
Nominal supply voltage
Current consumption
Power consumption
Transmission error, max.
Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Test voltage, input/output/supply
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada
GL

330

PHOENIX CONTACT

U input
0 ... 5 V / 1 ... 5 V
0 ... 10 V / 2 ... 10 V
Approx. 100 k
U output
0 ... 5 V / 1 ... 5 V
0 ... 10 V / 2 ... 10 V
Approx. 12.5 V
Approx. 22 mA
10 k
< 20 mVPP (on 10 kOhm)
U output
19.2 V DC ... 30 V DC
24 V DC
< 9 mA (Voltage output,
at 24 V DC incl. load)
< 200 mW (Voltage output)
0.1% (of end value)
< 0.01%/K, Typ. < 0.002%/K
Approx. 100 Hz
Approx. 3.2 ms
1.5 kV (50 Hz, 1 min.)
IP20
-20C ... 65C
Any
PBT

I input
0 ... 20 mA / 4 ... 20 mA
Approx. 50
I output
0 ... 20 mA / 4 ... 20 mA
28 mA
Approx. 12.5 V
< 500 (at 20 mA)
< 20 mVPP (at 500 )
I output

< 19 mA (Current output,


at 24 V DC incl. load)
< 450 mW (Current output)

CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL EMC 2 D

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Pcs. /
Pkt.

1
1
1
1

INTERFACE Analog
MINI Analog
Order key MINI MCR-SL-UI-UI (Standard configuration entered as example)
Input
Order No.
2864383

Output

2864383 =
...-UI-UI

IN03
IN01
IN02
IN03
IN04
IN05
IN06

2864710 =
...-UI-UI-SP

=
=
=
=
=
=

0...20 mA
4...20 mA
0...10 V
2...10 V
0...5 V
1...5 V

Factory calibration
certificate
/
OUT01
/
NONE
NONE = Without certificate
OUT01 = 0...20 mA
YES
= With factory
calibration
OUT02 = 4...20 mA
certificate (fee)
OUT03 = 0...10 V
OUT04 = 2...10 V
YESPLUS = Factory calibration certificate
OUT05 = 0...5 V
with 5 measuring
OUT06 = 1...5 V
points (fee)

Combination table for input and output signals

Input
0 - 10 V

Output
0 - 20 mA
4 - 20 mA
0 - 10 V
2 - 10 V
0-5V
1-5V
0 - 20 mA
4 - 20 mA
0 - 10 V
2 - 10 V
0-5V
1-5V
0 - 20 mA
4 - 20 mA
0 - 10 V
2 - 10 V
0-5V
1-5V
0 - 20 mA
4 - 20 mA
0 - 10 V
2 - 10 V
0-5V
1-5V
0 - 20 mA
4 - 20 mA
0 - 10 V
2 - 10 V
0-5V
1-5V
0 - 20 mA
4 - 20 mA
0 - 10 V
2 - 10 V
0-5V
1-5V

2 - 10 V

0-5V

1-5V

0 - 20 mA

4 - 20 mA

DIP 1
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON

DIP switch SW 2
DIP 3
DIP 4
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF

DIP 2
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON

DIP 5
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF

DIP switch SW 1
DIP 1
DIP 2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON

DIP 6
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF

Application example: Level measurement

24V

Level sensor

0...10V

0...20mA
1 IN

OUT 5

2 GND1

GND2 6
Control system

3 UB+

UB+ 7

4 GND3

GND3 8
MINI MCR-SL-UI-UI

24V

Mains voltage

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

331

INTERFACE Analog
MINI Analog
Configurable 3-way isolation
amplifiers
6,2

Isolation

102,5

93,1

IN

U,I

OUT

MINI MCR-SL-SHUNT-UI
SL

POWER

Configurable 3-way isolation amplifiers

uF

Housing width 6.2

Conversion from mV voltages into


standard signals
Configurable input and output signals
3-way isolation
Low power consumption
Power supply possible through the foot
element (T-Connector)
The MINI MCR-SL-SHUNT-UI 3-way
isolation amplifiers convert mV voltages
into standard signals. Amplification, filtering
and electrical isolation of signals takes place
here.
These devices make it possible to record
direct currents flowing through a shunt
resistor. The resulting voltage drop of a few
millivolts is converted into a standard signal
using an isolation amplifier and can be
forwarded by a control system.
The DIP switch accessible on the housing
side allows the configuration of the input
signal ranges and the desired output signal.
The desired configuration must be
specified when ordering pre-configured
modules (refer to the order key). If
specifications are incorrect or missing, the
devices will be supplied with the standard
configuration.
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

IN U 1
GND1 2

PHOENIX CONTACT

U,I

5 OUT UI
6 GND2

DC DC

solid

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Screw
M3

DC

7 UB +
8 GND3

UB + 3
GND3 4
ME 6,2 TBUS-...

Description

Type

Order No.

MCR-3-way isolation amplifier, for realization of mV voltages in


standard signals,
Order configuration
Screw connection
Order configuration
Spring-cage conn.
Standard configuration
Screw connection
Standard configuration
Spring-cage conn.

MINI MCR-SL-SHUNT-UI
MINI MCR-SL-SHUNT-UI-SP
MINI MCR-SL-SHUNT-UI-NC
MINI MCR-SL-SHUNT-UI-SP-NC

2810858
2810874
2810780
2810793

Technical data
Input data
Input signal (configurable using the DIP switch)
Maximum input signal
Input resistance
Output data
Output signal (configurable using the DIP switch)

Maximum output signal


Load RB
Ripple
General data
Supply voltage UB
Nominal supply voltage
Power consumption
Transmission error, max.
Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Test voltage, input/output/supply
Degree of protection
Ambient temperature (operation)
Ambient temperature (storage/transport)
Assembly
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada
GL

332

Ex: X // Applied for: UL-EX LIS / CUL-EX LIS

Pcs. /
Pkt.

0 ... 50 mV, please indicate any different setting when ordering


Approx. 30 V DC
Approx. 100 k
U output
I output
0 ... 5 V / 1 ... 5 V
0 ... 20 mA / 4 ... 20 mA
0 ... 10 V / 2 ... 10 V
-5 ... 5 V / -10 ... 10 V
(The bi-polar output can be used
only for bi-polar input signals.)
12.5 V
10 k
< 20 mVPP (on 10 kOhm)

28 mA
< 500 (at 20 mA)
< 20 mVPP (at 500 )

19.2 V DC ... 30 V DC
24 V DC
< 450 mW (Current output)
0.2%
< 0.01%/K
(100 Hz / 30 Hz switchable)
3.5 ms (at 100 Hz)
1.5 kV (50 Hz, 1 min.)
IP20
-20C ... 65C
-40C ... 85C
Any
PBT
CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Zone 2, Groups A, B, C, D T5 applied for
GL EMC 2 D

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

1
1
1
1

INTERFACE Analog
MINI Analog
Order key MINI MCR-SL-SHUNT-UI-... (Standard configuration entered as example)
Input
Order No.
2810858
2810858 =
...-SHUNT-UI
2810874 =
...-SHUNT-UI-SP

Output

IN40
IN40
IN24
IN41
IN42
IN25
IN43
IN44
IN26
IN45
IN27

=
=
=
=
=
=
=
=
=
=

0...50 mV
0...60 mV
0...75 mV
0...80 mV
0...100 mV
0...120 mV
0...150 mV
0...200 mV
0...240 mV
0...300 mV

IN28
IN46
IN47
IN48
IN29
IN49
IN50
IN30
IN51
IN52

=
=
=
=
=
=
=
=
=
=

0...500 mV
0...600 mV
0...750 mV
0...800 mV
0...1.0 V
0...1.2 V
0...1.5 V
0...2.0 V
0...2.4 V
0...3.0 V

IN53
IN13
IN54
IN55
IN14
IN56
IN57
IN15
IN58
IN16

/
=
=
=
=
=
=
=
=
=
=

-50...+50 mV
-60...+60 mV
-75..+75 mV
-80...+80 mV
-100..+100 mV
-120...+120 mV
-150...+150 mV
-200...+200 mV
-240...+240 mV
-300...+300 mV

IN17
IN59
IN60
IN61
IN18
IN62
IN63
IN19
IN64
IN65

=
=
=
=
=
=
=
=
=
=

-500...+500 mV
-600...+600 mV
-750...+750 mV
-800...+800 mV
-1.0...+1.0 V
-1.2...+1.2 V
-1.5...+1.5 V
-2.0...+2.0 V
-2.4...+2.4 V
-3.0...+3.0 V

Limit frequency

OUT01
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06

=
=
=
=
=
=

0...20 mA
4...20 mA
0...10 V
2...10 V
0...5 V
1...5 V

100
30 = 30 Hz
100 = 100 Hz

OUT13 = -5...+5 V
OUT14 = -10...+10 V

Factory calibration
certificate
/
NONE
= Without certificate
= With factory
calibration
certificate (fee)
YESPLUS = Factory
calibration
certificate with
5 measuring
points (fee)
NONE
YES

Note:
A bipolar output (-5...+5 V, -10...+10 V) is useful only in case of a bipolar input signal.

Combination table for input and output signals

Input
0...50 mV
0...60 mV
0...75 mV
0...80 mV
0...100 mV
0...120 mV
0...150 mV
0...200 mV
0...240 mV
0...300 mV
0...500 mV
0...600 mV
0...750 mV
0...800 mV
0...1 V
0...1.2 V
0...1.5 V
0...2 V
0...2.4 V
0...3 V
-50...50 mV
-60...60 mV
-75...75 mV
-80...80 mV
-100...100 mV
-120...120 mV
-150...150 mV
-200...200 mV
-240...240 mV
-300...300 mV
-500...500 mV
-600...600 mV
-750...750 mV
-800...800 mV
-1...1 V
-1.2...1.2 V
-1.5...1.5 V
-2...2 V
-2.4...2.4 V
-3...3 V

-10...+10 V

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Voltage output
2...10 V
-5...+5 V
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

0...10 V
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

0...5 V
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Current output
0...20 mA
4...20 mA
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1...5 V
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Application example: Monitoring of loading and discharging currents

G
M

Shunt
resistor

1 IN

OUT 5

...mV

U/I
2 GND1

GND2 6
Control system

3 UB+

UB+ 7

4 GND3

GND3 8

MINI MCR-SL-SHUNT-UI

24V

Battery
Supply

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

333

INTERFACE Analog
MINI Analog
Configurable 3-way isolation
amplifiers
93,1

Isolation

102,5

6,2

IN

U,I

OUT

MINI MCR-SL-U-UI
POWER

SL

Configurable 3-way isolation amplifiers

uF

Ex: X U

Housing width 6.2

Processing voltages of up to 30 V
Configurable input and output signals
3-way isolation
Low power consumption
Power supply possible through the foot
element (T-Connector)

The MINI MCR-SL-U-UI 3-way


isolation amplifiers are used for electrical
isolation, conversion, amplification and
filtering of voltages up to 30 V. These can be
the output voltages of power supply units
or UPS.
The devices that can be adjusted via DIP
switches are electrically isolated from each
other in the input, output and supply circuit.
This 3-way isolation prevents different
sensor circuits interfering with each other
and thereby improves the quality of your
measuring circuit.
The desired configuration must be
specified when ordering pre-configured
modules (refer to the order key). If
specifications are incorrect or missing, the
devices will be supplied with the standard
configuration.
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

IN U 1
GND1 2

Screw connection
Spring-cage conn.

OUT

DC

Screw
M3

GND1

GND2

Type

Order No.

MCR 3-way isolation amplifier, for electrical isolation of analog


signals,
Order configuration
Screw connection
Order configuration
Spring-cage conn.
Standard configuration
Screw connection
Standard configuration
Spring-cage conn.

MINI MCR-SL-U-UI
MINI MCR-SL-U-UI-SP
MINI MCR-SL-U-UI-NC
MINI MCR-SL-U-UI-SP-NC

2864053
2811213
2865007
2810078

Technical data
Input data
Input signal
Input resistance
Output data
Output signal (configurable using the DIP switch)

0 ... 24 V / 0 ... 30 V
Approx. 125 k
U output
0 ... 5 V / 1 ... 5 V
0 ... 10 V / 2 ... 10 V
12.5 V

Maximum output signal


No-load voltage
Short-circuit current
Load RB
Ripple
General data
Supply voltage UB
Power consumption
Transmission error, max.
Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Test voltage, input/output/supply
Ambient temperature (operation)
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada

UB+

2864053 = ...-U-UI

UB +

2811213 = ...-U-UI-SP
4

GND3

GND3

MINI MCR-SL-U-UI

24V

22 mA
> 10 k
< 20 mVPP (on 10 kOhm)

Output
IN39

IN38
IN39

= 0...24 V
= 0...30 V

OUT01
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06

=
=
=
=
=
=

0...20 mA
4...20 mA
0...10 V
2...10 V
0...5 V
1...5 V

Mains voltage

PHOENIX CONTACT

28 mA
12.5 V
< 500 (at 20 mA)
< 20 mVPP (at 500 )

CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL EMC 2 D

Input
/

I output
0 ... 20 mA / 4 ... 20 mA

19.2 V DC ... 30 V DC
< 450 mW
< 0.1% (of end value)
< 0.01%/K, Typ. < 0.002%/K
100 Hz
Approx. 3.5 ms
1.5 kV (50 Hz, 1 min.)
-20C ... 65C
PBT

Signal conversion to uninterruptible power supply (UPS)

334

7 UB +
8 GND3

UB + 3
GND3 4

Description

2864053

5 OUT UI
6 GND2

ME 6,2 TBUS-...

Order No.
0...10V
IN U

U,I
DC DC

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Order key MINI MCR-SL-U-UI (Standard configuration entered as example)

solid

GL

0...24V

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Pcs. /
Pkt.

1
1
1
1

INTERFACE Analog
MINI Analog
Standard signal 3-way isolation
amplifiers
93,1

Isolation

102,5

6,2

IN

U,I

U,I

OUT

MINI MCR-SL-U-I(I-U)
SL

POWER

3-way isolation amplifier

uF

Ex: X // Applied for: UL-EX LIS / CUL-EX LIS

Housing width 6.2

Processing standard signals


Fixed setting of input and output signals
3-way isolation
Low power consumption
Power supply possible through the foot
element (T-Connector)

The MINI MCR-SL-U-I(I-U) 3-way


isolation amplifiers are used for electrical
isolation, conversion, amplification and
filtering of analog standard signals.
The devices are electrically isolated from
each other in the input, output and supply
circuit.
A new type of connection concept makes
the devices very low-loss with regard to
their power consumption. This is expressed
in low self-heating and has a significant
influence on the service life.
Thanks to the possibility of power
bridging via the foot element, the devices
can be connected to the power supply both
simply and quickly.

IN 1
GND1 2

DC DC

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Screw
M3

DC

7 UB +
8 GND3

UB + 3
GND3 4
ME 6,2 TBUS-...

Description

Order No.

MCR 3-way isolation amplifier, for electrical isolation of analog


signals,
Screw connection
0 ... 10 V
0 ... 20 mA
Spring-cage conn.
0 ... 10 V
0 ... 20 mA

MINI MCR-SL-U-I-0
MINI MCR-SL-U-I-0-SP

2813512
2813570

1
1

Screw connection
Spring-cage conn.

0 ... 10 V
0 ... 10 V

4 ... 20 mA
4 ... 20 mA

MINI MCR-SL-U-I-4
MINI MCR-SL-U-I-4-SP

2813525
2813583

1
1

Screw connection
Spring-cage conn.

0 ... 20 mA
0 ... 20 mA

0 ... 10 V
0 ... 10 V

MINI MCR-SL-I-U-0
MINI MCR-SL-I-U-0-SP

2813541
2813554

1
1

Screw connection
Spring-cage conn.

4 ... 20 mA
4 ... 20 mA

0 ... 10 V
0 ... 10 V

MINI MCR-SL-I-U-4
MINI MCR-SL-I-U-4-SP

2813538
2813567

1
1

Screw connection

0 ... 20 mA,
4 ... 20 mA
0 ... 20 mA,
4 ... 20 mA
0 ... 10 V,
-10 ... 10 V
0 ... 10 V,
-10 ... 10 V

0 ... 20 mA,
4 ... 20 mA
0 ... 20 mA,
4 ... 20 mA
0 ... 10 V,
-10 ... 10 V
0 ... 10 V,
-10 ... 10 V

MINI MCR-SL-I-I

2864406

MINI MCR-SL-I-I-SP

2864723

MINI MCR-SL-U-U

2864684

MINI MCR-SL-U-U-SP

2864697

Spring-cage conn.

Spring-cage conn.
Technical data
Input data
Input resistance
Output data
Maximum output signal
No-load voltage
Short-circuit current
Load RB
Ripple
General data
Supply voltage UB
Nominal supply voltage
Current consumption
Transmission error, max.
Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Degree of protection
Test voltage, input/output/supply
Ambient temperature (operation)
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada
GL

Input signal

Output signal

Pcs. /
Pkt.

Type

Screw connection
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

5 OUT
6 GND2

U input
Approx. 100 k
U output
12.5 V
Approx. 2 mA
10 k
< 20 mVPP (on 10 kOhm)

I input
Approx. 50
I output
28 mA
Approx. 12.5 V
500
< 20 mVPP (at 500 )

19.2 V DC ... 30 V DC
24 V DC
< 20 mA
0.1% (of end value)
< 0.01%/K, Typ. < 0.002%/K
Approx. 100 Hz
Approx. 3.5 ms
IP20
1.5 kV (50 Hz, 1 min.)
-20C ... 65C
PBT
CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL EMC 2 D

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

335

INTERFACE Analog
MINI Analog
Configurable signal duplicator

93,1

6,2

102,5

OUT1
Isolation

I
IN

U,I

OUT2

MINI MCR-SL-UI-2I
POWER

SL

Configurable signal duplicator

uF

Ex: X U

Housing width 6.2


URef

Configurable input and output signals


4-way isolation
Two current output signals
Power supply possible through the foot
element (T-Connector)

The MINI MCR-SL-UI-2I 4-way signal


duplicators are used for electrical isolation,
duplicating and filtering of analog standard
signals.
The devices are electrically isolated from
each other in the input, output and supply
circuit. 4-way isolation prevents different
sensor circuits interfering with each other
and thereby improves the quality of your
measuring circuit.
The input signal can be switched over
between the current and voltage signal via a
DIP switch and the two current output
signals can be switched independently
between 0...20 mA and 4...20 mA.
The desired configuration must be
specified when ordering pre-configured
modules (refer to the order key). If
specifications are incorrect or missing, the
devices will be supplied with the standard
configuration.
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

IN UI 1
2
solid

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Input

2864794 =
...-UI-2I
2864804 =
...-UI-2I-SP

1)

IN03
IN01
IN02
IN03
IN06

=
=
=
=

0...20 mA
4...20 mA
0...10 V
1...5 V

OUT I2 3
GND2 4

PHOENIX CONTACT

DC
DC

DC
DC

7 UB +
8 GND4

Type

Order No.

MCR signal duplicator, for duplicating and electrical isolation of


analog signals
Order configuration
Screw connection
Order configuration
Spring-cage conn.
Standard configuration
Screw connection
Standard configuration
Spring-cage conn.

MINI MCR-SL-UI-2I
MINI MCR-SL-UI-2I-SP
MINI MCR-SL-UI-2I-NC
MINI MCR-SL-UI-2I-SP-NC

2864794
2864804
2864176
2864189

Technical data
Input data
Input signal
Maximum input signal
Input resistance
Output data
Output signal (configurable using the DIP switch)
Maximum output signal
No-load voltage
Load RB
Ripple
General data
Supply voltage UB
Current consumption
Power consumption
Transmission error, max.
Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Test voltage, input/output/supply
Ambient temperature (operation)
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada

0 = Analog behavior
1 = Limit

Factory calibration
certificate
/
NONE
NONE = Without certificate
YES
= With factory
calibration
certificate (fee)
YESPLUS = Factory calibration certificate
with 5 measuring
points (fee)

U input
0 ... 10 V / 1 ... 5 V
30 V
Approx. 100 k

I input
0 ... 20 mA / 4 ... 20 mA
50 mA
Approx. 50

2x ; 0 ... 20 mA / 4 ... 20 mA
24 mA
9V
250 (at 20 mA)
< 20 mVPP (at 250 )
19.2 V DC ... 30 V DC
< 25 mA (at 24 V DC incl. load)
< 600 mW
0.2% (of end value), Typ. < 0.1%
< 0.01%/K, Typ. < 0.004%/K
Approx. 35 Hz
Approx. 10 ms
1.5 kV (50 Hz, 1 min.)
-20C ... 60C
PBT
CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL EMC 2 D

Explanation of the output combination:


Output 1
A
0...20 mA
B
0...20 mA
C
4...20 mA

For explanations see adjacent text on the right, for further details see data sheet: www.phoenixcontact.com

336

5 OUT I1
6 GND1

mC

Description

Output
Behavior of the analog
combination 1) outputs
/
A
/
0
A
B
C

ME 6,2 TBUS-...

GL
Order key MINI MCR-SL-UI-2I (Standard configuration entered as example)

Order No.
2864794

Screw
M3

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Output 2
0...20 mA
4...20 mA
4...20 mA

Pcs. /
Pkt.

1
1
1
1

INTERFACE Analog
MINI Analog
Repeater power supply with and
without HART
6,2

102,5

Isolation

93,1

POWER

OUT

IN

MINI MCR-SL-RPSS-I-I
POWER

SL

Repeater power supply for supplying 2 and 3-conductor transmitters


with HART transmission

Ex: X

Housing width 6.2

IN 1

3-way isolation
Supplying of 2 or 3-conductor
transmitters
lternatively bidirectional HART
transmission
Power supply possible through the foot
element (T-Connector)

Sensor
Power

solid

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Description
MCR repeater power supplies
with HART protocol
with HART protocol

Technical data
Input data
Input signal

4...20mA

OUT I

GND2

GND1

UB +

GND1

GND3

MINI MCR-SL-RPSS-I-I

Control system

7 UB +
8 GND3

24V

Screw connection
Spring-cage conn.
Screw connection
Spring-cage conn.

Type

Order No.

MINI MCR-SL-RPSS-I-I
MINI MCR-SL-RPSS-I-I-SP
MINI MCR-SL-RPS-I-I
MINI MCR-SL-RPS-I-I-SP

2864079
2810230
2864422
2864752

Pcs. /
Pkt.

1
1
1
1

MINI MCR-SL-RPS-I-I

0 ... 20 mA, isolator operation /


4 ... 20 mA
Approx. 50
16.5 V

0 ... 20 mA, isolator operation /


4 ... 20 mA
Approx. 50
14.7 V DC ... 25.5 V DC
(UB max. 4.5 V for load
0 mA ... 20 mA)

0 ... 20 mA / 4 ... 20 mA
21 mA
Approx. 12.5 V
500 (at I = 20 mA)
< 20 mVrms (at 500 )

0 ... 20 mA / 4 ... 20 mA
28 mA
Approx. 12.5 V
500 (at I = 20 mA)
< 20 mVrms (at 500 )

20.4 V DC ... 30 V DC
24 V DC

19.2 V DC ... 30 V DC
24 V DC

< 900 mW (at 24 V DC and in


repeater power supply operation)
0.2% (of end value),
Typ. 0.1% (of end value)
< 0.005%/K, Typ. < 0.002%/K
> 125 Hz (typ.)
HART specification in both
operating modes (RPSS isolator
/ RPSS repeater power supply)

< 900 mW (at 24 V DC and in


repeater power supply operation)
0.2% (of end value),
Typ. 0.1% (of end value)
< 0.01%/K, Typ. < 0.002%/K
Approx. 100 Hz
-

Step response (10-90%)


Test voltage, input/output/supply
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada

< 2 ms (typ.)
1.5 kV (50 Hz, 1 min.)
IP20
-20C ... 60C
Any
PBT

Approx. 3.5 ms
1.5 kV (50 Hz, 1 min.)
IP20
-20C ... 60C
Any
PBT

CE compliant
X II 3 G Ex nA II T4 X
-

GL

CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D
T5
GL EMC 2 D

Input resistance
Transmitter supply voltage

Output data
Output signal
Maximum output signal
No-load voltage
Load RB
Ripple
General data
Supply voltage UB
Nominal supply voltage
Power consumption

Temperature coefficient
Limit frequency (3 dB)
Communication

IN I

DC

GND1 3
GND1 4

MINI MCR-SL-RPSS-I-I

Transmission error, max.

Power OUT

DC DC

OUT 2
Screw
M3

ME 6,2 TBUS-...

Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 337.

5 OUT I
6 GND2

The MINI MCR-SL-RPS(S)-I-I


repeater power supplies have the task of
supplying 2 or 3-conductor transmitters
located in the field and transmitting the
analog signals electrically isolated from the
transmitter.
Besides this basic function, the MINI
MCR-SL-RPSS-I-I repeater power supply
is also capable of transmitting the HART
protocol bidirectionally. For this, the digital
signals of data communication are super
imposed on the analog current signals. In
addition, a pure isolator operation is also
possible.
Both devices are electrically isolated from
each other in the input, output and supply
circuit.

2 Sensor

Mains voltage

Repeater power supply operation with a passive sensor

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

337

INTERFACE Analog
MINI Analog
One and two-channel passive isolators

6,2

Isolation

102,5

93,1

IN

OUT

MINI MCR-SL-...CP-I-I
SL

One or two-channel passive isolators

uF

Ex: u

Housing width 6.2


OUT

IN

Electrical isolation without additional


auxiliary power supply
Current signals 0(4)...20 mA
One and two-channel versions
Input loop-supplied

5 (+) 0-20mA
6 () GND

(+) 0-20mA 1
2
() GND

5 (+) 0-20mA
6 () GND

solid

Screw connection
Spring-cage conn.

The MINI MCR-SL-...CP-I-I passive


isolators are used for electrical isolation and
filtering of analog 0(4)...20 mA standard
signals.
The devices perform electrical isolation
between the control electronics and
process peripherals. Furthermore,
interference signal parts above 75 Hz are
effectively suppressed.
Input and output circuits do not require
separate auxiliary power, the modules
obtain it from the input signal.
When passive loop-powered isolators are
used, one must make sure that the current
sourcing voltage of the measuring
transducer UB is sufficient to drive the
maximum current of 20 mA via the passive
loop-powered isolator with the voltage
drop UV = 1.7 V and the load RB.
This means:
UB UE = 1.7 V + 20 mA x RB

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

(+) 0-20mA 1
2
() GND

Screw
M3

(+) 0-20mA 3
4
() GND

Description

Type

Order No.

MCR passive isolator, for electrical isolation of current signals


without auxiliary power
two-channel
Screw connection
two-channel
Spring-cage conn.
single-channel
Screw connection
single-channel
Spring-cage conn.

MINI MCR-SL-2CP-I-I
MINI MCR-SL-2CP-I-I-SP
MINI MCR-SL-1CP-I-I
MINI MCR-SL-1CP-I-I-SP

2864655
2864781
2864419
2864749

Technical data
Input data
Input signal
Voltage drop
Response current
Maximum input current / overload
Maximum input voltage
Output data
Output signal
Load RB
Ripple
General data
Transmission error, max.
Additional error per 100 load
Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Test voltage input/output
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada
GL

0 ... 20 mA / 4 ... 20 mA
1.7 V (at I = 20 mA)
Approx. 190 A
40 mA
18 V
0 ... 20 mA / 4 ... 20 mA
< 600 (at I = 20 mA output signal)
< 10 mVrms (at 600 )
0.1% (of end value)
0.03% (of measured value / 100 load)
0.002%/K (of measured value / 100 load)
75 Hz
5 ms (at 600 load)
1.5 kV (50 Hz, 1 min.)
IP20
-20C ... 65C
Any
PBT
CE compliant
UL 508 Recognized
GL EMC 2 D

UB

UV = 1,7 V

I
UE

I
RB

I
MINI MCR-SL-1CP-I-I

338

PHOENIX CONTACT

7 (+) 0-20mA
8 () GND

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Pcs. /
Pkt.

1
1
1
1

INTERFACE Analog
MINI Analog
Configurable temperature transducer
for Pt 100
6,2

102,5

Temperature

93,1

IN

U,I

OUT

PT100

SL

MINI MCR-SL-PT100-UI-200

POWER

Configurable temperature transducer for Pt 100 temperature


sensors for measuring ranges of -50...200C

uF

Ex: X U

Housing width 6.2

The MINI MCR-SL-PT100-UI-200


temperature transducers convert the
measured values of Pt 100 sensors
(IEC 60751/EN 60751) into analog standard
signals. These temperature transducers
are optimized for measuring ranges of
-50 to 200C.
2, 3 and 4-conductor Pt 100 sensors can
be connected to the input. The DIP
switches are accessible at the side of the
housing and allow the following parameters
to be configured: Connection method,
temperature span to be measured, output
signal, and type of error evaluation.
The desired configuration must be
specified when ordering pre-configured
modules (refer to the order key). If
specifications are incorrect or missing, the
devices will be supplied with the standard
configuration.
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

2
3

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Screw
M3

Description

2 Wire Pt 100

solid

4 Wire Pt 100

Measuring ranges from 50C to 200C


2, 3 or 4-conductor Pt 100 sensors
Configurable output signals
3-way isolation
Diagnostics LED and fault evaluation
Power supply possible through the foot
element (T-Connector)

3 Wire Pt 100

Iref
A
D

5 OUT UI
6 GND1

mC

DC DC
DC

7 UB+
8 GND2

ME 6,2 TBUS-...

Type

Order No.

MINI MCR-SL-PT100-UI-200
MINI MCR-SL-PT100-UI-200-SP
MINI MCR-SL-PT100-UI-200-NC
MINI MCR-SL-PT100-UI-200-SP-NC

2864309
2864192
2864370
2864202

Pcs. /
Pkt.

MCR temperature transducer, for PT100 temperature sensors


Order configuration
Order configuration
Unconfigured
Unconfigured

Screw connection
Spring-cage conn.
Screw connection
Spring-cage conn.

Technical data
Input data
Input signal (configurable via DIP switch)
Temperature range
Measuring range span
Output data
Output signal (configurable via DIP switch)
Maximum output signal
Load RB
Ripple
General data
Supply voltage UB
Current consumption
Power consumption
Transmission error for the full/set measurement range
Temperature coefficient
Step response (10-90%)
Test voltage, input/output/supply
Ambient temperature (operation)
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada
GL

1
1
1
1

Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-wire


-50C ... 200C (configurable)
Min. 50 K
I output
U output
0 ... 20 mA / 4 ... 20 mA
0 ... 5 V / 1 ... 5 V
20 ... 0 mA / 20 ... 4 mA
0 ... 10 V / 10 ... 0 V
23 mA
Approx. 12.5 V
< 500 (at 20 mA)
> 10 k
< 20 mVPP (at 500 )
< 20 mVPP (on 10 kOhm)
19.2 V DC ... 30 V DC
< 21 mA (for 24 V DC)
< 500 mW
0.25% ; ((50 K / Temp)+ 0.05)%
< 0.02%/K
< 200 ms
1.5 kV (50 Hz, 1 min.)
-20C ... 65C
PBT
CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL EMC 2 D

Order key MINI MCR-SL-PT100-UI-200 (Standard configuration as example)


Measuring range [C]
Output
Failure
Factory calibration
Failure information (depends on the output signal range):
information 1) certificate
Start
End
Measured value overrange
Open circuit
/
0
/
100
/
OUT01
/
A
/
NONE
0...20 mA 4...20 mA
0...10 V 0...20 mA 4...20 mA 0...10 V
20.5 mA
10.25 V
21 mA
21 mA 10.5 V
0
Area
OUT01 = 0...20 mA
A
NONE = Without certificate A 20.5 mA
B 20.5 mA
20.5 mA
10.25 V
21 mA
21 mA 10.5 V
2864309 =
-5
(width of step) OUT02 = 4...20 mA
B
YES
= With factory
C
20
mA
20
mA
10
V
21
mA
21
mA 10.5 V
calibration
...-PT100-UI-200
3 = 3-wire
-10
OUT03 = 0...10 V
C
D
20
mA
20
mA
10
V
0
mA
4 mA
0V
certificate (fee)
-15
0...200 (5 K) OUT05 = 0...5 V
D
Measured value underrange
Short circuit
2864192 =
4 = 4-wire
-20
OUT06 = 1...5 V
YESPLUS = Factory calibra0...20 mA 4...20 mA
0...10 V 0...20 mA 4...20 mA 0...10 V
tion certificate
...-PT100-UI-200-SP
-30
OUT07 = 20...0 mA
with 5 measuring A
-40
OUT08 = 20...4 mA
0 mA
4 mA
0V
0 mA
4 mA
0V
B
0 mA
3.5 mA
0V
0 mA
3 mA
0V
points (fee)
-50
OUT09 = 10...0 V
C
0 mA
4 mA
0V
21 mA
21 mA 10.5 V
1) For explanations see adjacent text on the right, for further details see data sheet: www.phoenixcontact.com
D
0 mA
4 mA
0V
0 mA
4 mA
0V
Order No.
2864309

Connection
method
/
3
2 = 2-wire

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

339

INTERFACE Analog
MINI Analog
Configurable temperature transducer
for Pt 100
6,2

102,5

Temperature

93,1

IN

U,I

OUT

PT100

MINI MCR-SL-PT100-UI

POWER

SL

Configurable temperature transducer for Pt 100 temperature


sensors for measuring ranges of -150C ... 850C

uF

Ex: X U

Housing width 6.2

The MINI MCR-SL-PT100-UI


temperature transducers convert the
measured values of Pt 100 sensors
(IEC 60751/EN 60751) into analog standard
signals. These temperature transducers
are optimized for measuring ranges of
-150 to 850C.
2, 3 and 4-conductor Pt 100 sensors can
be connected to the input. The DIP
switches are accessible at the side of the
housing and allow the following parameters
to be configured: Connection method,
temperature span to be measured, output
signal, and type of error evaluation.
The desired configuration must be
specified when ordering pre-configured
modules (refer to the order key). If
specifications are incorrect or missing, the
devices will be supplied with the standard
configuration.
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

2
3

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Screw
M3

Description

2 Wire Pt 100

solid

4 Wire Pt 100

Measuring ranges from 150C to 850C


2, 3 or 4-conductor Pt 100 sensors
Configurable output signals
3-way isolation
Diagnostics LED and fault evaluation
Power supply possible through the foot
element (T-Connector)

3 Wire Pt 100

Iref
A
D

5 OUT UI
6 GND1

mC

DC DC
DC

7 UB+
8 GND2

ME 6,2 TBUS-...

Type

Order No.

MINI MCR-SL-PT100-UI
MINI MCR-SL-PT100-UI-SP
MINI MCR-SL-PT100-UI-NC
MINI MCR-SL-PT100-UI-SP-NC

2864435
2864736
2864273
2864286

Pcs. /
Pkt.

MCR temperature transducer, for PT100 temperature sensors


Order configuration
Order configuration
Unconfigured
Unconfigured

Screw connection
Spring-cage conn.
Screw connection
Spring-cage conn.

Technical data
Input data
Input signal (configurable via DIP switch)
Temperature range
Measuring range span
Output data
Output signal (configurable via DIP switch)

1
1
1
1

Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-wire


-150C ... 850C (configurable)
Min. 50 K
I output
U output
0 ... 20 mA / 4 ... 20 mA
0 ... 5 V / 1 ... 5 V
20 ... 0 mA / 20 ... 4 mA
0 ... 10 V / 10 ... 0 V
23 mA
Approx. 12.5 V
< 500 (at 20 mA)
10 k
< 20 mVPP (at 500 )
< 20 mVPP (on 10 kOhm)

Maximum output signal


Load RB
Ripple
General data
Supply voltage UB
Current consumption
Power consumption
Transmission error for the full/set measurement range
Temperature coefficient
Step response (10-90%)
Test voltage, input/output/supply
Ambient temperature (operation)
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada

19.2 V DC ... 30 V DC
< 21 mA (for 24 V DC)
< 500 mW
0,2% ; ((100 K / set measurement range [K]) + 0.1)%
< 0.02%/K
< 160 ms
1.5 kV (50 Hz, 1 min.)
-20C ... 65C
PBT
CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL EMC 2 D

GL
Order key MINI MCR-SL-PT100-UI (Standard configuration entered as example)

Order No.
2864435
2864435 =
...-PT100-UI

Connection
method
/
3
2 = 2-wire
3 = 3-wire

2864736 =
4 = 4-wire
...-PT100-UI-SP

1)

Measuring range [C]


Output
Failure
Factory calibration
information 1) certificate
Start
End
/
0
/
100
/
OUT01
/
A
/
NONE
0
Area
OUT01 = 0...20 mA
A
NONE = Without certificate
-10
(width of step)
OUT02 = 4...20 mA
B
YES
= With factory
calibration
-20
OUT03 = 0...10 V
C
certificate (fee)
-30
0...100 (5 K) OUT05 = 0...5 V
D
-40
110...300 10 K OUT06 = 1...5 V
YESPLUS = Factory calibration certificate
-50
320...700 (20 K) OUT07 = 20...0 mA
with 5 measuring
-100
750...850 (50 K) OUT08 = 20...4 mA
points (fee)
-150
OUT09 = 10...0 V

For explanations see adjacent text on the right, for further details see data sheet:
www.phoenixcontact.com

340

PHOENIX CONTACT

Failure information (depends on the output signal range):


Measured value overrange
Open circuit
0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 0...10 V
A 20.5 mA
20.5 mA
10.25 V
21 mA
21 mA 10.5 V
B 20.5 mA
20.5 mA
10.25 V
21 mA
21 mA 10.5 V
C
20 mA
20 mA
10 V
21 mA
21 mA 10.5 V
D
20 mA
20 mA
10 V
0 mA
4 mA
0V

A
B
C
D

Measured value underrange


0...20 mA 4...20 mA 0...10 V
0 mA
4 mA
0V
0 mA
3.5 mA
0V
0 mA
4 mA
0V
0 mA
4 mA
0V

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Short circuit
0...20 mA 4...20 mA 0...10 V
0 mA
4 mA
0V
0 mA
3 mA
0V
21 mA
21 mA 10.5 V
0 mA
4 mA
0V

INTERFACE Analog
MINI Analog
Configurable loop-powered
temperature transducer for Pt 100

IN

I
PT100

POWER

6,2

102,5

Temperature

93,1

OUT

MINI MCR-SL-PT100-LP

SL

Configurable loop-powered temperature transducer for Pt 100


temperature sensors for measuring ranges of -150...300C

u
Housing width 6.2

The MINI MCR-SL-PT100-UI-LP


loop-powered temperature transducers
convert the measured values of Pt 100
sensors (IEC 60751/EN 60751) into analog
standard signals. These temperature
transducers are optimized for measuring
ranges of -150 to 300C.
2, 3 and 4-conductor Pt 100 sensors can
be connected to the input. On the output
side, the module is operated in a 4...20 mA
current loop, which simultaneously provides
the power supply needed for signal
conversion. The DIP switches are accessible
at the side of the housing and allow the
following parameters to be configured:
Connection method, temperature span to
be measured, output signal, and type of
error evaluation.
The desired configuration must be
specified when ordering pre-configured
modules (refer to the order key). If
specifications are incorrect or missing, the
devices will be supplied with the standard
configuration.

Screw
M3

2 Wire Pt 100

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

solid

URef

4 Wire Pt 100

No separate voltage supply


Measuring ranges from 150C to 300C
2, 3 or 4-conductor Pt 100 sensors
Configurable output signals
2-way isolation
Diagnostics LED and fault evaluation

3 Wire Pt 100

Applied for: UL-EX LIS / CUL-EX LIS

J
D

5 OUT I
6 GND 1

mC

DC
DC

7 NC
8 NC

Description

Type

Order No.

MCR temperature transducer, for Pt 100 temperature sensors,


loop-powered
Order configuration
Screw connection
Order configuration
Spring-cage conn.
Unconfigured
Screw connection
Unconfigured
Spring-cage conn.

MINI MCR-SL-PT100-LP
MINI MCR-SL-PT100-LP-SP
MINI MCR-SL-PT100-LP-NC
MINI MCR-SL-PT100-LP-NC-SP

2810298
2810382
2810308
2810395

Technical data
Input data
Input signal (configurable via DIP switch)
Temperature range
Measuring range span
Output data
Output signal
Maximum output signal
Load RB
Ripple
General data
Supply voltage UB
Current consumption
Power consumption
Transmission error for the full/set measurement range
Temperature coefficient
Step response (10-90%)
Test voltage, input/output/supply
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada

Pcs. /
Pkt.

1
1
1
1

Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-wire


-150C ... 300C (configurable)
Min. 50 K
4 ... 20 mA / 20 ... 4 mA
23 mA (output limit)
((Usupply - 12 V) / 22 mA)
< 20 mVPP (at 500 )
12 V DC ... 30 V DC
< 3.5 mA (without signal current)
< 42 mW (without signal current)
0.25% ; ((90 K / set measuring range [K]) + 0.05)%
< 0.02%/K
< 200 ms
1.5 kV (50 Hz, 1 min.)
IP20
-20C ... 65C
Any
PBT
CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for

Order key MINI MCR-SL-PT100-LP (Standard configuration entered as example)

Order No.
2810298
2810298 =
...-PT100-LP
2810382 =
...-PT100-LP-SP

1)

Connection
method
/
3
2 = 2-wire
3 = 3-wire
4 = 4-wire

Measuring range [C]


Output
Failure
Factory calibration
information 1) certificate
Start
End
/
0
/
100
/
OUT02
/
1
/
NONE
0
Area
NONE = Without certificate
-10
(width of step)
OUT02 = 4...20 mA
1
YES
= With factory
calibration
-20
OUT08 = 20...4 mA
2
certificate (fee)
-30
0...300 (5 K)
3
-40
4
YESPLUS = Factory calibration
certificate with
-50
5 measuring
-100
points (fee)
-150

For explanations see adjacent text on the right, for further details see data sheet: www.phoenixcontact.com

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Failure information:
Measured value
overrange
1
2
21.5 mA
3
3.5 mA
4
21.5 mA

1
2
3
4

Measured value
underrange
21.5 mA
3.5 mA
3.5 mA

Open circuit
Measuring range start
21.5 mA
3.5 mA
21.5 mA
Short circuit
Measuring range start
21.5 mA
3.5 mA
3.5 mA

PHOENIX CONTACT

341

INTERFACE Analog
MINI Analog
Configurable temperature transducer
for Type J and K thermocouples
6,2

102,5

Temperature

93,1

IN

U,I

OUT

MINI MCR-SL-TC-UI
POWER

SL

Configurable temperature transducer for thermocouples for


measuring ranges of -150...1350C

uF

Ex: X U

Housing width 6.2

URef

Measuring ranges from 150C to 1350C


Configurable output signals
3-way isolation
Diagnostics LED and fault evaluation
Power supply possible through the foot
element (T-Connector)

TC

J
D

5 OUT UI
6 GND1

mC

solid

Screw connection

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12

2
3

DC DC

Screw
M3

CJC

DC

7 UB +
8 GND2
ME 6,2 TBUS-...

The MINI MCR-SL-TC-UI


temperature transducers convert the
measured values of thermocouple sensors
(IEC 60584-1/ EN 60584-1) of types J and K
into analog standard signals.
Both type J and type K thermocouples
can be connected at the input. The DIP
switches are accessible at the side of the
housing and allow the following parameters
to be configured: Connection method,
temperature span to be measured, output
signal, and type of error evaluation.
The desired configuration must be
specified when ordering pre-configured
modules (refer to the order key). If
specifications are incorrect or missing, the
devices will be supplied with the standard
configuration.
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

Description

Order configuration
Unconfigured

Screw connection
Screw connection

Technical data
Input data
Input signal (configurable via DIP switch)
Temperature range

Maximum output signal


No-load voltage
Short-circuit current
Load RB
Ripple
General data
Supply voltage UB
Power consumption
Transmission error for the full/set measurement range
Cold point errors
Temperature coefficient
Step response (10-90%)
Test voltage, input/output/supply
Ambient temperature (operation)
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada

Measuring range [C]


Output
Failure
Factory calibration
information 1) certificate
Start
End
/
3
/
0
/
1000
/
OUT01
/
A
/
NONE
J = Type J
0
Area
OUT01 = 0...20 mA
A
NONE = Without certificate
-10
(width of step)
OUT02 = 4...20 mA
B
YES
= With factory
calibration
K = Type K
-20
OUT03 = 0...10 V
C
certificate (fee)
-30
OUT05 = 0...5 V
D
-40
0...300 10 K OUT06 = 1...5 V
YESPLUS = Factory calibration certificate
-50
320...700 (20 K) OUT07 = 20...0 mA
with 5 measuring
-100
750...1350 (50 K) OUT08 = 20...4 mA
points (fee)
-150
OUT09 = 10...0 V

For explanations see adjacent text on the right, for further details see data sheet: www.phoenixcontact.com

342

PHOENIX CONTACT

MINI MCR-SL-TC-UI
MINI MCR-SL-TC-UI-NC

2864448
2864299

Pcs. /
Pkt.

1
1

Thermocouples type J, K (IEC 584-1)


Typ J : -150C ... 1200C (configurable)
Typ K : -150C ... 1350C
Min. 50 K
I output
U output
0 ... 20 mA / 4 ... 20 mA
0 ... 5 V / 1 ... 5 V
20 ... 0 mA / 20 ... 4 mA
0 ... 10 V / 10 ... 0 V
23 mA
Approx. 12.5 V
Approx. 12.5 V
Approx. 10 mA
< 500 (at 20 mA)
10 k
< 20 mVPP (at 500 )
< 20 mVPP (on 10 kOhm)

Measuring range span


Output data
Output signal (configurable via DIP switch)

Sensor type

1)

Order No.

MCR temperature transducer, for thermocouples

19.2 V DC ... 30 V DC
< 500 mW
0,2% ; ((150 K / set measurement range [K]) + 0.1)%
< 3 K ( Typ. < 2 K )
< 0.02%/K
< 30 ms
1.5 kV (50 Hz, 1 min.)
-20C ... 65C
PBT
CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL EMC 2 D

GL
Order key MINI MCR-SL-TC-UI (Standard configuration entered as example)

Order No.
2864448

Type

Failure information (depends on the output signal range):


Measured value overrange
Open circuit
0...20 mA 4...20 mA
0...10 V 0...20 mA 4...20 mA 0...10 V
A 20.5 mA
20.5 mA
10.25 V
21 mA
21 mA 10.5 V
B 20.5 mA
20.5 mA
10.25 V
21 mA
21 mA 10.5 V
C
20 mA
20 mA
10 V
21 mA
21 mA 10.5 V
D
20 mA
20 mA
10 V
0 mA
4 mA
0V

A
B
C
D

Measured value underrange


0...20 mA 4...20 mA
0...10 V
0 mA
4 mA
0V
0 mA
3.5 mA
0V
0 mA
4 mA
0V
0 mA
4 mA
0V

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MINI Analog
Configurable analog frequency
transducer
93,1

Conversion

102,5

6,2

IN

U,I

OUT

MINI MCR-SL-UI-F
POWER

SL

Configurable analog frequency transducer

uF

Ex: X // Applied for: UL-EX LIS / CUL-EX LIS

Housing width 6.2

URef

Conversion from analog to frequency and


PWM signals
Adjustable interference filter
Configurable input and output signals
Diagnostics LED and fault evaluation
3-way isolation
Power supply possible through the foot
element (T-Connector)
The MINI MCR-SL-UI-F analog
frequency transducers are used to convert
analog standard signals to frequency signals.
These can then be further processed with
the digital input of a controller. The
standard analog signals can also be
converted to pulse width modulated
(PWM) signals (5-95%). A filter can be set
to smooth interference on the input signal.
DIP switches on the side of the housing
allow the following parameters to be set:
input signal, output signal, behavior of the
signal in the event of measuring overrange
or underrange, type of filter.
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

Frequency output
T

Variable frequency / Period duration T

IN UI 1
GND 1 2

5 OUT +
6 GND -

mC

solid

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

DC DC

Screw
M3

DC

UB+ 3
GND 2 4

7 UB+
8 GND2

ME 6,2 TBUS-...

Description

Type

Order No.

MINI MCR-SL-UI-F
MINI MCR-SL-UI-F-SP

2864082
2810243

Pcs. /
Pkt.

MCR frequency transducer


Screw connection
Spring-cage conn.
Technical data
Input data
Input signal (configurable via DIP switch)
Maximum permissible input level
Input resistance
Behavior in the event of an error
Output data
Output signal (configurable via DIP switch)

Minimum load
Load current maximum
Maximum switching voltage
Overrange/underrange
Protective circuitry
General data
Supply voltage UB
Nominal supply voltage
Current consumption
Power consumption
Transmission error, max.
Temperature coefficient
Step response (10-90%)
Test voltage, input/output/supply
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada
GL

1
1

I input
U input
0 ... 20 mA / 4 ... 20 mA
0 ... 5 V / 1 ... 5 V
0 ... 10 mA / 2 ... 10 mA
0 ... 10 V / 2 ... 10 V
100 mA
30 V DC
Approx. 50
Approx. 110 k
Alarm in the form of a LED red
Frequency output
PWM output
0 Hz ... 10 kHz / 0 Hz ... 5 kHz
7.8 kHz (10 bit) / 3.9 kHz (10 bit)
0 Hz ... 2.5 kHz / 0 Hz ... 1 kHz
1.9 kHz (12 bit) / 977 Hz (12 bit)
0 Hz ... 500 Hz / 0 Hz ... 250 Hz 488 Hz (14 bit) / 244 Hz (14 bit)
0 Hz ... 100 Hz / 0 Hz ... 50 Hz
122 Hz (16 bit) / 61 Hz (16 bit)
6000
2000
20 mA
30 V
Can be set (via DIP switch)
Short circuit protection, polarity reversal protection
19.2 V DC ... 30 V DC
24 V DC
< 10 mA (for 24 V DC)
< 200 mW
< 0.1%
< 0.02%/K
< 15 ms / < 1 s (with the largest filter)
1.5 kV (50 Hz, 1 min.)
IP20
-20C ... 65C
Any
PBT
CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL EMC 2 D

PWM output (pulse width modulation)


T

Variable pulse-pause ratio / Fixed period duration T

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

343

INTERFACE Analog
MINI Analog
Configurable potiposition transducer

93,1

Conversion

102,5

6,2

IN

U,I

OUT

MINI MCR-SL-R-UI
POWER

SL

Configurable potiposition transducer

uF

Ex: X // Applied for: UL-EX LIS / CUL-EX LIS

Housing width 6.2

For potentiometers from 100 to 100 k


Automatic potentiometer detection
Configurable measuring range and output
signals
"Teach in" function for limit values
Signaling the measurement overrange and
underrange
3-way isolation
Power supply possible through the foot
element (T-Connector)

2
3

DC DC

DC

solid

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Screw
M3

5 OUT UI
6 GND1

mC

7 UB+
8 GND2

ME 6,2 TBUS-...

Description

Type

Order No.

MINI MCR-SL-R-UI
MINI MCR-SL-R-UI-SP

2864095
2810256

Pcs. /
Pkt.

MCR potiposition transducer

The MINI MCR-SL-R-UI


potentiometer measuring transducers
convert potentiometer positions into an
analog standard signal. The devices can be
used for potentiometers with a resistance
value of 0...100 to 0...100 k.
If the potentiometer range cannot be
utilized to the full for technical reasons,
externally accessible trimmers/switches
provide for simple and precise
compensation of the analog signal. An
additional LED lights up if the measuring
range is exceeded or fallen below.
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

Lifting platform

ACTUAL SETPOINT
0...10V
0...10V

Actuator motor

Potentiometer

Screw connection
Spring-cage conn.
Technical data
Input data
Potentiometer
Reference voltage source
Output data
Output signal
Maximum output signal
No-load voltage
Short-circuit current
Load RB
Ripple
Behavior in the event of a sensor error
General data
Supply voltage UB
Nominal supply voltage
Current consumption
Power consumption
Transmission error, max.
Temperature coefficient
Step response (10-90%)
Test voltage, input/output/supply
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada
GL

100 ... 100 k


< 3.6 V
U output
0 ... 5 V / 1 ... 5 V
0 ... 10 V / 10 ... 0 V
12.5 V
Approx. 10 mA
> 10 k
< 20 mVPP (on 10 kOhm)
Configurable 0% ... 105%

OUT

CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL EMC 2 D

GND1

Control system
6

UB +

GND2

MINI MCR-SL-R-UI

24V
Mains voltage

Height adjustment of a lifting platform with


setpoint and actual value control

344

PHOENIX CONTACT

< 500 (20 mA)


< 20 mVPP (at 500 )

19.2 V DC ... 30 V DC
24 V DC
< 25 mA (for 24 V DC)
< 500 mW
< 0.2%
< 0.02%/K
< 30 ms
1.5 kV (50 Hz, 1 min.)
IP20
-20C ... 65C
Any
PBT

Controller

I output
0 ... 20 mA / 4 ... 20 mA
20 ... 0 mA / 20 ... 4 mA
23 mA
Approx. 12.5 V

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

1
1

INTERFACE Analog
MINI Analog
Configurable NAMUR switching
amplifier
93,1

Control

102,5

6,2

IN

OUT

MINI MCR-SL-NAM-2RNO
SL

POWER

Configurable NAMUR switching amplifier

uF

Housing width 6.2

IN

For operating proximity sensors, floating


switching contacts and switching contacts
with resistance circuit
Configurable N/O contacts
3-way isolation
Power supply possible through the foot
element (T-Connector)
The MINI MCR-SL-NAM-2RNO
isolation amplifiers condition, isolate and
duplicate signals from proximity sensors in
acc. with IEC 60947-5-6, EN 50227. It is
also possible to connect floating switching
contacts or switching contacts with
resistance circuit.
The isolation amplifiers detect line faults
on the input side and switch the outputs to
a deenergized state when an error is
detected. If the second N/O contact is used
as an alarm output, the relay is activated
when an error is detected.
The DIP switches are accessible at the
side of the housing and allow the following
parameters to be configured:
Second N/O contact can be used to
duplicate signals or as an alarm output
Line fault detection can be deactivated
(necessary when switching contacts are
connected)
Switchover between operating current
and quiescent current (inverted switching
behavior)
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

Ex: X // Applied for: UL-EX LIS / CUL-EX LIS

+ 1
- 2

5 13
OUT1
6 14
DC DC
DC

solid

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Screw
M3

13 3
OUT2
14 4
7 UB+
8 GND

ME 6,2 TBUS-...

Description

Type

Order No.

MINI MCR-SL-NAM-2RNO
MINI MCR-SL-NAM-2RNO-SP

2864105
2810269

Pcs. /
Pkt.

MCR NAMUR switching amplifier


Screw connection
Spring-cage conn.
Technical data
Input data
Input signal

Control circuit
No-load voltage
Switching points (in acc. with IEC 60947-5-6)
Line error detection
Switching output
Relay output
Contact material
Max. switching voltage
Max. switching current
Min. contact current
Switching frequency
General data
Supply voltage UB
Nominal supply voltage
Current consumption
Power consumption
Test voltage, input/output/supply
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada
GL

1
1

NAMUR proximity sensors


Floating switching contacts
Switching contacts with resistance circuit
8.2 V DC 10%
< 1.2 mA (disabling)
> 2.1 mA (conducting)
> 6 mA (in the event of a short circuit)
< 0.1 mA (with wire break)
2 N/O contacts
AgSnO2, hard gold-plated
250 V AC
2A
1 mA (for 5 V DC)
10 Hz
19.2 V DC ... 30 V DC
24 V DC
< 25 mA
< 600 mW
1.5 kV (50 Hz, 1 min.)
IP20
-20C ... 60C
Any
PBT
CE compliant
X II 3 G Ex nAC IIC T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL EMC 2 D

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

345

INTERFACE Analog
MINI Analog
Configurable threshold value switch

93,1

Control

102,5

6,2

IN

U,I

OUT

MINI MCR-SL-UI-REL
SL

POWER

Threshold value switch with relay output

uF

Ex: X U

Housing width 6.2

3-way isolation
Adjustable limit values, hysteresis and
delay time
Operating current / Quiescent current
switchover
Power supply possible through the foot
element (T-Connector)
The MINI MCR-SL-UI-REL threshold
value switches are used for monitoring
standard signals.
The devices that can be adjusted via DIP
switches and potentiometers are
electrically isolated from each other in the
input, output and supply circuit.
The limit value of the analog input signal
0...10 V or 0(4)...20 mA can be preselected
with a DIP switch and accurately set via a
potentiometer. If the input signal reaches
the limit value, a PDT relay contact is
actuated at the output. If necessary, a DIP
switch can be used to switch a hysteresis
around the limit value.
The response behavior of the PDT relay
can also be set via a DIP switch using the
operating current or quiescent current
principle.
Two LEDs signal the relay status (yellow)
and alarm (red).
Accessories:
Information about components for energy bridging, system cabling
and marking is given from page 347.

346

PHOENIX CONTACT

IN UI 5
GND1 6

1
2
3
4

mC

solid

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

N.C.
14
11
12

DC

Screw
M3

DC

7 UB +
8 GND2
ME 6,2 TBUS-...

Description

Type

Order No.

MINI MCR-SL-UI-REL
MINI MCR-SL-UI-REL-SP

2864480
2864493

Pcs. /
Pkt.

MCR threshold value switch


Screw connection
Spring-cage conn.
Technical data
Input data
Input signal (configurable via DIP switch)
Maximum permissible input level
Input resistance
Specification of the switching point
Switching output
Relay output
Contact material
Max. switching voltage
Limiting continuous current
Hysteresis (configurable using the DIP switch)
Operating and closed circuit current behavior
Setting range of the response delay (configurable using the DIP
switch)
General data
Supply voltage UB
Nominal supply voltage
Current consumption
Power consumption
Linearity error
Temperature coefficient
Step response (10-90%)
Test voltage input/power supply
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada
UL, USA
UL, Canada
GL

I input
0 ... 20 mA
100 mA
50
With 25-speed potentiometer

U input
0 ... 10 V
30 V
> 100 k

1 PDT
AgSnO2, hard gold-plated
250 V AC
2A
(0.1%; 1%; 2.5%; 5%)
Switchable using DIP switch
0 s ... 10 s (0 s; 1 s; 2 s; 3 s; 4 s; 6 s; 8 s; 10 s)

19.2 V DC ... 30 V DC
24 V DC
< 14 mA (for 24 V DC)
< 330 mW (for 24 V DC)
< 0.05% (of end value)
< 0.02%/K
< 35 ms
1.5 kV AC (50 Hz, 1 min.)
IP20
-20C ... 65C
Any
PBT
CE compliant
X II 3 G Ex nAC IIC T4 X
UL 508 Recognized
Class I, Zone 2, AEx nC IIC T6
Class I, Zone 2, Ex nC IIC T6
GL EMC 2 D

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

1
1

INTERFACE Analog
MINI Analog
Accessories
Feed-through terminal blocks

The 6.2 mm wide MINI MCR-SL-TB


feed-through terminal block helps in 1:1
forwarding of signals in the MINI Analog
unit.
The inner structure consists of a simple
direct connection without conversion or
electrical isolation of the generated signals.
The feed-through terminal block can be
used in the standard unit as well as as an
addition for the system cabling.
For example, if a system cabling is desired
and only seven signals are present, the gap
can be cost-effectively filled using a feedthrough terminal block.
For more information about how you can
make use of the numerous advantages of
the system cabling, see page 350.

solid

Screw connection

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 24-12

Screw
M3

MINI MCR-SL-TB
Description

Type

Order No.

MINI MCR-SL-TB

2811420

Pcs. /
Pkt.

MCR feed-through terminal block


Technical data
General data
Degree of protection
Ambient temperature (operation)
Assembly
Housing material

IP20
-20C ... 65C
Any
PBT

Accessories
Marking material
MINI MCR DKL and MINI MCRDKL-LABEL allow flexible labeling of
MINI Analog modules.
The hinged transparent cover is snapped
onto the module and a stamped insert strip
is pushed into the side of the cover.
Moreover, labeling is possible with the flat
Zack marker strip ZBF 6 marker labels.

MINI MCR DKL


Description

Type

Order No.

Pcs. /
Pkt.

Fold up transparent cover, for labeling MINI Analog modules with


insert strips
Insert strips, stamped, for transparent cover

MINI MCR DKL

2308111

10

MINI MCR-DKL-LABEL

2810272

10

Flat-ribbon labeling (see CLIPLINE catalog)

ZBF 6...

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

347

INTERFACE Analog
MINI Analog
Accessories
Power terminals
Redundant supply possible
For up to 80 MINI analog modules
With signal LED
The MINI MCR-SL-PTB power
terminal with the same shape allows
redundant supply of the supply voltage
through the foot element (T-connector).
The diode-decoupled redundant infeed
increases the system availability. The power
terminal is snapped conveniently onto the
foot element and can thus supply up to
80 MINI analog modules.
The current carrying capacity of the
power terminal is 2 A. A green power LED
signals the applied supply voltage. A LED
red at each input signals a supply voltage
applied with reverse polarity on the power
terminal.
Recommended fuse for power terminal:
Fuse in acc. with IEC 60127-2/V
Nominal current: 2.5 A
Characteristics: Slow-blow
(e.g. Wickmann 5 x 20 mm/No. 195 - glass fuse)

solid

Screw connection
Spring-cage conn.

stranded
[mm2]
AWG
0.14-2.5 0.2-2.5 26-12
0.2-2.5
0.2-2.5 24-12

Screw
M3

MINI MCR-SL-PTB
Description
MCR power terminal

Screw connection
Spring-cage conn.

Technical data
Input data
Input voltage range
Current consumption
Output data
Output voltage
Output current
General data
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada
GL

Type

Order No.

MINI MCR-SL-PTB
MINI MCR-SL-PTB-SP

2864134
2864147

Pcs. /
Pkt.
1
1

0 V DC ... 30 V DC
Max. 2 A
(Input voltage - 0.8 V)
2A
IP20
-20C ... 65C
Any
PBT
CE compliant
X II 3 G Ex nA II T4 X
UL 508 Recognized
GL EMC 2 D

Accessories
DIN rail connector
The T-connector ME 6,2 TBUS-...
serves to bridge the supply voltage. MINI
Analog modules can thus be connected
quickly and with less wiring. This makes
module replacement during the process less
complicated.
The T-connectors can be extended
between each other and can be snapped
onto 35 mm DIN rails acc. to EN 60715.
A T-connector supplies power to two
MINI Analog modules each. The maximum
current carrying capacity is 8 A transverse
(parallel to the DIN rail when using the
system current supply) as well as 2 A to the
MINI Analog module (even when using the
power terminal).

348

PHOENIX CONTACT

ME 6,2 TBUS-2...
Description

Type

Order No.

Pcs. /
Pkt.

DIN rail connector (T bus), for bridging the supply voltage, can
be snapped onto 35 mm DIN rails as per EN 60715, with UL
approval

ME 6,2 TBUS-2 1,5/5-ST-3,81 GN

2869728

10

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MINI Analog
Accessories
System power supply
MINI SYS POWER
The DIN rail connector of the system
power supply allows additional modules of
the same system to be supplied with a
regulated 24 V DC voltage. The low height
of just 102.5 mm allows installation in flat
control cabinets.
MINI POWER EX
Power compact for the decentral
automation.
The power supply unit complies with
standard EN 60079-15 and may be installed
within the potentially explosive area in
which category 3G items are necessary.

MINI 24 V DC/1.5 A(/EX)


Pcs. /
Pkt.

Description

Type

Order No.

System power supply unit, primary-switched with zone 2


approval.
More information is given in the INTERFACE Power Supply catalog
part.
System power supply unit, primary-switched (not for zone 2)
More information is given in the INTERFACE Power Supply catalog
part.

MINI-PS-100-240AC/24DC/1.5/EX

2866653

MINI-SYS-PS-100-240AC/24DC/1.5

2866983

Accessories
DIN rail connector
The T-connector ME 17,5 TBUS-...
serves to bridge the supply voltage when
using a MINI POWER system power supply
unit.
If the system power supply unit is used,
two T-connectors ME 17,5 TBUS are
required to establish a connection to the
T-connectors ME 6,2 TBUS of the MINI
Analog unit and to supply them effectively
with power.

ME 17,5 TBUS 1,5/ 5-ST-3,81 GN


Description

Type

Order No.

Pcs. /
Pkt.

DIN rail connector, for bridging the supply voltage, can be


snapped onto 35 mm DIN rails as per EN 60715, with UL approval,
two pieces are required per system power supply

ME 17,5 TBUS 1,5/ 5-ST-3,81 GN

2709561

10

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

349

INTERFACE Analog
MINI Analog
Accessories
System cabling
In many applications, analog signal
transmission on 6 mm means a high
number of channels in confined spaces.
Error-free, time-efficient and cost-saving
wiring solutions therefore have utmost
significance in this regard.
The MINI Analog system cabling enables
quick, easy and error-free wiring of up to
eight channels.
System cabling can be implemented using
different methods.
System cabling with front adapters
This includes:
16-pos. FLK cable
The V8 system adapter for MINI Analog
modules
One front adapter that must be
specifically selected for the analog card of
the control system
In this solution, the components simply
need to be plugged together. There is
virtually no further wiring cost. In addition,
it is no longer possible to make mistakes in
wiring since the pre-assembled
components already have the correct
assignment.
System cabling without front
adapters
This ideal substitute is the version that
does not use a front adapter.
A 16-pos. FLK cable with open ends on
one side is used in this case. The open ends
are provided with ferrules and numbers.
As a result, you can connect this system
cable to almost every module that is not
equipped with a front adapter. It is
advantageous owing to the fast, quick and
error-free system cabling on the module
side.

V8 system adapter
for MINI Analog

16-pos. FLK cable

Front adapter for analog card

System cabling with front adapters

Project planning help is given in the


following table. Please visit our website or
contact us to get information regarding
other solutions.

Project planning help for MINI Analog system cabling


Control system

Analog card

Front adapter

Siemens
SIMATIC S7-300 /
ET 200 M

6ES7-331-7KF02-0AB0
6ES7-331-7KB02-0AB0
6ES7-331-7KB81-0AB0
6ES7-331-7TF00-0AB0
6ES7-332-8TF01-0AB0

FLKM 16-PA-S300/MINI-MCR
(On page 210 in the catalog)

6ES7-331-1KF01-0AB0
(For current signals)

FLKM 16-PA-331-1KF/I/MINI-MCR
(On page 211 in the catalog)

6ES7-331-5HF00-0AB0
(For current signals)

FLKM 16-PA-332-5HF/I/MINI-MCR
(On page 211 in the catalog)

Yokogawa
Centum CS 3000 R3

AAI 141
Not required
AAI 143

FLK cable

V8 system adapter for MINI Analog

FLK 16/EZ-DR/.../KONFEK
(Non-molded connector,
on page 264 in the catalog)

MINI MCR-SL-V8-FLK 16-A


(On page 352 in the catalog)

CABLE-40/2/FLK16/.../YUC
(Non-molded connector,
on page 223 in the catalog)

2 x MINI MCR-SL-V8-FLK 16-A


(On page 352 in the catalog)

CABLE-FLK16/OE/0,14/...M
(Non-molded connector,
on page 260 in the catalog)
Other control systems /
actuators / sensors

All cards

Not required

or optionally
VIP-CAB-FLK16/FR/OE/0,14/...M
(Molded connector,
on page 260 in the catalog)

350

PHOENIX CONTACT

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

MINI MCR-SL-V8-FLK 16-A


(On page 352 in the catalog)

INTERFACE Analog
MINI Analog

V8 system adapter
for MINI Analog

Pluggable connection

16-pos. VIP or FLK cable


with open ends

Innovative concept

System cabling without front adapters

Innovative concept
The MINI MCR-SL-V8-FLK 16-A MINI
Analog system adapter can be used on the
input as well as output sides due to the
innovative design concept. As a result,
there is nothing preventing the system
cabling of input and output modules using
the same components.

More protection
The new VIP cables with molded FLK
connectors provide increased protection
in rough industrial environments. In the
case of system cabling without front
adapters, you have the option of using the
advantages of the new VIP cable on the
system adapter side.

Complete flexibility
The proven FLK selecting cables and
series offers complete flexibility when
selecting and is the ideal solution for
system cabling with front adapters. The
flat, stranded connector connections allow
problem-free accommodation in any
analog module.

Supplement
If system cabling with less than eight
channels needs to be implemented, the
MINI MCR-SL-TB feed-through terminal
block (page 347) is the ideal substitute.

Complete flexibility

More protection

Supplement

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

351

INTERFACE Analog
MINI Analog
Accessories
MINI Analog system adapter
Thanks to its new plug-in concept, the
MINI Analog system adapter MINI MCRSL-V8 FLK 16-A provides a time-saving
wiring solution. Eight MINI Analog signal
converters are connected to a control unit
easily by means of pluggable system cabling.
Therefore, the cabling cost and the wiring
error risk in applications with greater signal
quantities are reduced considerably in
comparison with the PLS-side singleconductor wiring.
Universal "Plug and Play" solutions can be
offered in connection with the INTERFACE
cabling products.

MINI MCR-SL-V8-FLK 16-A


System adapter

uF

Ex: X // Applied for: UL-EX LIS / CUL-EX LIS


Description

Type

Order No.

MINI MCR-SL-V8-FLK 16-A

2811268

Pcs. /
Pkt.

System adapter, for MINI analog modules with screw connection

Technical data
Connection to the signal level
Insertion/withdrawal cycles (System adapter / FLK 16 )
Contact resistance
Current carrying capacity
Test voltage
Ambient temperature (operation)
Vibration resistance
Surge voltage category / Pollution degree
Dimensions W / H / D
Conformance / approvals
ATEX
UL, USA / Canada
GL

352

PHOENIX CONTACT

Flat-ribbon cable connector, 16-pos.(FLK 16)


10 / Min. 200
< 10 m
Max. 1 A
500 V (50 Hz, 1 min. from channel to channel)
-20C ... 60C
Max. 0.7 g
III / 2
50.4 mm / 45.5 mm / 46.2 mm

X II 3 G Ex nA II T4 X
UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL EMC 2 D

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MINI Analog
YOKOGAWA Centum CS3000 R3
Motherboard for MINI Analog system
cabling
The MINI Analog motherboard UM1222KS40 enables effective connection of 16
MINI Analog modules to Yokogawa analog
modules.
Furthermore, a redundant feed, an alarm
via a relay in the event of a power failure,
and a redundant connection to two analog
modules are possible.
The motherboard is delivered with all
components for assembly with MINI Analog
modules. Only the isolation amplifiers
required for the application must be
selected and ordered.
More motherboard solutions are available
on the Internet. For the relevant system
cables for connecting the motherboard to
the analog modules, see page 223.

H W
D

UM122-2KS40/16/MINI-MCR/UNI
Motherboard for up to 16 MINI analog modules

Description

Type

Order No.

UM122-2KS40/16/MINI-MCR/UNI

2319210

Pcs. /
Pkt.

Motherboard, for MINI Analog system cabling

Technical data
General data
Connection to the field level
Connection to the control system level
Supply voltage
Protection against polarity reversal
Operating voltage monitoring

Directly to MINI analog modules


40-pos. KS connectors
19.2 V DC ... 30 V DC
Yes
The failure of one of the two supplies is indicated by the respective
LED green extinguishing and by the relay contact opening.

Safety monitoring

Fusing is indicated by a red illuminated LED and the relay contact


opening.

Ambient temperature range


Housing material
Dimensions W / H / D

-20C ... 55C


PVC
216 / 122 / 140 mm

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

353

INTERFACE Analog
MINI Analog
Accessories
Surge protection
LINETRAB LIT
An ideal supplement to MINI Analog the innovative surge protection solution in
a 6.2 mm housing.
Owing to the uniform shape of the
housings of LINETRAB LIT and MINI
Analog, the numerous advantages of
system cabling can be used. The
combination of MINI Analog and
LINETRAB LIT is advantageous for you
since you get a space-saving, perfectly
coordinated and protected signal chain
from the sensor to the control system.
Project planning help for the MINI
Analog / LINETRAB combination options
is given in the following tables.
The components and the combination
options for implementing system cabling
between MINI Analog and LINETRAB are
listed on the left side.
Details regarding system cabling
between MINI Analog and the control
system side are given on page 350.
Detailed information regarding
LINETRAB LIT surge protection modules
is given in the TRABTECH catalog.

Assembled 16-pos. round cable


VIP-CAB-FLK16/FR...

V8 system adapter for


MINI Analog

LINETRAB LIT
Surge protection modules

Safe measurement using the LINETRAB LIT and MINI Analog system

Project planning help for LINETRAB LIT - MINI Analog


Cabling via MINI Analog system adapter (8 modules)
LINETRAB LIT (surge protection)
Type

LIT 1X2-24

MINI Analog
Order No.

Type

Order No.

2804610

MINI MCR-SL-UI-UI
MINI MCR-SL-UI-UI-NC
MINI MCR-SL-U-UI-NC
MINI MCR-SL-U-I-0
MINI MCR-SL-U-I-4
MINI MCR-SL-I-U-0
MINI MCR-SL-I-U-4
MINI MCR-SL-I-I
MINI MCR-SL-U-U
MINI MCR-SL-UI-2I
MINI MCR-SL-UI-2I-NC
MINI MCR-SL-RPS-I-I
MINI MCR-SL-RPSS-I-I
MINI MCR-SL-1CP-I-I
MINI MCR-SL-UI-F
MINI MCR-SL-NAM-2RNO
MINI MCR-SL-UI-REL
MINI MCR-SL-SHUNT-UI
MINI MCR-SL-SHUNT-UI-NC

2864383
2864150
2865007
2813512
2813525
2813541
2813538
2864406
2864684
2864794
2864176
2864422
2864079
2864419
2864082
2864105
2864480
2810858
2810780

Components required for system cabling


Available 16-pos. VIP... round cable
Type

V8 system adapter for MINI Analog


Length

Order No.

VIP-CAB-FLK16/FR/FR/0,14/0,5M
0.5 m
2900154
VIP-CAB-FLK16/FR/FR/0,14/1,0M
1.0 m
2900155
VIP-CAB-FLK16/FR/FR/0,14/2,0M
2.0 m
2900156
Special lengths of VIP... round cable are available on request.

354

PHOENIX CONTACT

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Type
2 x MINI MCR-SL-V8-FLK 16-A
(On page 352 in the catalog)

INTERFACE Analog
MINI Analog

VIP system cable


The new VIP cables offer safe and rugged
connection in rough industrial
environments as well.
Innovative concept
The MINI Analog system adapter offers
the option of input and output-side system
cabling. An error-free and quick cabling is
also possible using LINETRAB surge
protection modules.

More protection
In addition to the advantages of
electrical isolation, filtering, amplification
and conversion of analog standard signals
using MINI Analog, it also offers effective
surge protection.
Surge protection
Surge protection is effective and
provides reliable protection against system
damage and downtimes. LINETRAB limits
transient surge voltages safely and without
affecting the signals - and all that in a design
width of just 6.2 mm!

VIP system cable

Innovative concept

Project planning help for LINETRAB LIT - MINI Analog


Manual cabling
LINETRAB LIT (surge protection)
Type

LIT 1X2-24

More protection

MINI Analog
Order No.

2804610

LIT 2X2-24

2804623

LIT 2-12
(For 2-wire connection method)

2804665

LIT 4-12
(For 3 and 4-wire connection method)

2804678

LIT 1X2-24

2804610

LIT 4-24

2804678

Type

Order No.

MINI MCR-SL-UI-UI
MINI MCR-SL-UI-UI-NC
MINI MCR-SL-UI-UI-SP
MINI MCR-SL-UI-UI-SP-NC
MINI MCR-SL-SHUNT-UI-SP
MINI MCR-SL-SHUNT-UI-SP-NC
MINI MCR-SL-U-UI-SP
MINI MCR-SL-U-UI-SP-NC
MINI MCR-SL-U-I-0-SP
MINI MCR-SL-U-I-4-SP
MINI MCR-SL-I-U-0-SP
MINI MCR-SL-I-U-4-SP
MINI MCR-SL-I-I-SP
MINI MCR-SL-U-U-SP
MINI MCR-SL-UI-2I-SP
MINI MCR-SL-UI-2I-SP-NC
MINI MCR-SL-RPS-I-I-SP
MINI MCR-SL-RPSS-I-I-SP
MINI MCR-SL-1CP-I-I-SP
MINI MCR-SL-2CP-I-I
MINI MCR-SL-2CP-I-I-SP
MINI MCR-SL-PT100-UI-200
MINI MCR-SL-PT100-UI-200-NC
MINI MCR-SL-PT100-UI-200-SP
MINI MCR-SL-PT100-UI-200-SP-NC
MINI MCR-SL-PT100-UI
MINI MCR-SL-PT100-UI-NC
MINI MCR-SL-PT100-UI-SP
MINI MCR-SL-PT100-UI-SP-NC
MINI MCR-SL-PT100-UI-LP
MINI MCR-SL-PT100-UI-LP-NC
MINI MCR-SL-PT100-UI-LP-SP
MINI MCR-SL-PT100-UI-LP-SP-NC
MINI MCR-SL-UI-F-SP
MINI MCR-SL-NAM-2RNO-SP
MINI MCR-SL-UI-REL-SP
MINI MCR-SL-R-UI
MINI MCR-SL-R-UI-SP

2864383
2864150
2864710
2864163
2810874
2810793
2811213
2810078
2813570
2813583
2813554
2813567
2864723
2864697
2864804
2864189
2864752
2810230
2864749
2864655
2864781
2864309
2864370
2864192
2864202
2864435
2864273
2864736
2864286
2810298
2810308
2810382
2810395
2810243
2810269
2864493
2864095
2810256

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Surge protection

PHOENIX CONTACT

355

INTERFACE Analog
MACX Analog / MCR Analog

Modular converters for MCR technology

356

PHOENIX CONTACT

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog

Isolation

MACX Analog / MCR Analog

Isolation:
Configurable and standard 3-way isolation
amplifiers with electrical isolation
between input, output, and supply
Configurable signal multipliers to double
analog standard signals
Repeater power supplies for supply and
signal transmission
Configurable loop-powered isolators and
standard passive isolators

The signal isolators are used to


electrically isolate, amplify, filter and adjust
analog signals.

Temperature

Isolation

Temperature:
Programmable temperature transducers
Configurable temperature transducers
for Pt 100
Temperature relays for Pt 100
Configurable temperature transducers
for thermocouples of the types J and K
Programmable loop-powered
temperature transducers

The temperature transducers convert


the input signals (e.g. Pt 100, Ni 1000, ... or
thermocouples of the types J, K, ...) into
standard signals.

Conversion

Temperature

Conversion:
Programmable frequency transducers for
frequencies of up to 120 kHz

The measuring transducers convert


different signal values to analog signals
suitable for the control system. Analog
signals are just as easy to adapt to the
control level as are frequencies, rotational
speeds and potentiometer positions.

Control

Conversion

Control:
Programmable threshold value switches
for resistance thermometers,
thermocouples and analog standard
signals
Threshold value switches for analog
standard signals
Constant voltage source for presetting a
reference voltage of 10 V
Programmable digital displays

Monitoring modules are also used in


measuring and control technology in
addition to the common control systems
such as PLCs and PCs. They record analog
signals and control and monitor a function
depending on the signal value.

Power

Control

Power:
Current transducers for sinusoidal and
non-sinusoidal alternating currents of up
to 100 A, 200 A or 400 A
Configurable and programmable true
r.m.s. value current transducers for
converting DC, AC and distorted
currents of up to 11 A or 55 A
Active and passive r.m.s. value current
transducers for converting sinusoidal AC
currents of up to 1 A or 5 A

Current protectors for sinusoidal


alternating currents of up to 16 A
The current and voltage transducers
convert currents and voltages into analog
standard signals.

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Power
PHOENIX CONTACT

357

INTERFACE Analog
MACX Analog / MCR Analog
Configurable 3-way isolation
amplifiers

99

114,5

Isolation

FL

12,5

IN

U,I

U,I

OUT

MACX MCR-UI-UI-UP
POWER

Configurable 3-way isolation amplifier with safe isolation and long


range supply.

Housing width 12.5

OUT

3-way isolation
Configurable input and output signals
Long range supply of
19.2 V AC/DC ... 253 V AC/DC

+
solid

The MACX MCR-UI-UI 3-way isolation


amplifiers are used for electrical isolation
and conversion of standard analog signals.
3-way isolation prevents different sensor
circuits interfering with each other and
thereby improves the quality of your
measuring circuit.
DIP switches enable the inputs and
outputs of the isolation amplifier to be
reconfigured, allowing more than 1600
signal conversions to be set.
The desired input and output signal
combination must be specified when
ordering pre-configured modules (refer to
the order key). If specification details are
incorrect or missing, the devices will be
supplied with the standard configuration
(input signal 0...10 V, output signal
0...20 mA).

Pluggable screw
connection
Spring-cage conn.

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

0.2-1.5

24-16

4.2

3.1

4.1

Passiv

Screw
M3

Description

2.2

5.2 GND

2.1

5.1

1V ... 100V

1.2

Type

Order No.

MACX MCR-UI-UI-UP
MACX MCR-UI-UI-UP-SP
MACX MCR-UI-UI-UP-NC
MACX MCR-UI-UI-UP-SP-NC

2811459
2811585
2811297
2811569

Pcs. /
Pkt.

MCR 3-way isolation amplifier, for electrical isolation of analog


signals with long-range power supply
Order configuration
Order configuration
Standard configuration
Standard configuration

Screw connection
Spring-cage connection
Screw connection
Spring-cage connection

Technical data
Input data
Input signal (configurable using the DIP switch)
Maximum input signal
Input resistance
Output data
Output signal (configurable using the DIP switch)
Maximum output signal
Load RB
General data
Supply voltage UB

Transmission error, max.


Temperature coefficient
ZERO / SPAN adjustment
Limit frequency (3 dB)
Step response (10-90%)
Test voltage, input/output/supply
Rated insulation voltage
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
ATEX
IECEx
UL, USA / Canada
Functional safety (SIL)
GL

PHOENIX CONTACT

3.2

50mV ... 1000mV


1mA ... 5mA
10mA ... 100mA

1.1

Power dissipation

358

0.2-1.5

IN
Aktiv

1
1
1
1

U input
I input
0 ... 10 V, please indicate any different setting when ordering
100 V
100 mA
Approx. 1 M
Approx. 10
( 1 V DC ... 100 V DC)
( 10 mA DC ... 100 mA DC)
U output
I output
0 ... 20 mA, please indicate any different setting when ordering
15 V
35 mA
1 k (10 V)
active: 600 (20 mA)
(passive: (UB-2 V) / Ioutmax)
24 V AC/DC ... 230 V AC/DC (-20%/+10%, 50/60 Hz)
< 0.8 W (at 24 V DC / 20 mA)
< 0.9 W (at 230 V AC / 20 mA)
0.1% (compared to the final value)
0.0075%/K
4% / 4%
10 kHz (Can be switched to 30 Hz)
35 s (at 10 kHz)
11 ms (at 30 Hz)
2.5 kV (50 Hz, 1 min.)
300 V AC
IP20
-20C ... 70C
Any
Polyamide (PA 6.6)
CE compliant
X II 3 G Ex nA nL II T4
Ex nA nL II T4
UL applied for
SIL 2 according to EN 61508
GL applied for

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Order key MACX MCR-UI-UI-... (Standard configuration entered as example)
Input
Order No.
2811459

Output

IN03
IN40
IN24
IN41
IN25
IN43
IN44
IN26
IN27
IN28
IN66
IN29
IN50
IN30
IN52
IN05
IN03
IN67
IN32
IN39
IN68
IN69

2811459 =
...-UI-UI-UP
2811585 =
...-UI-UI-UP-SP

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

0...50 mV
0...60 mV
0...75 mV
0...100 mV
0...120 mV
0...150 mV
0...200 mV
0...300 mV
0...500 mV
0...1000 mV
0...1.0 V
0...1.5 V
0...2.0 V
0...3.0 V
0...5 V
0...10 V
0...15 V
0...20 V
0...30 V
0...50 V
0...100 V

IN53
IN13
IN54
IN14
IN56
IN57
IN15
IN16
IN17
IN78
IN18
IN63
IN19
IN65
IN21
IN22
IN79
IN23
IN80
IN81
IN82

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Limit frequency

-50...+50 mV
-60...+60 mV
-75..+75 mV
-100..+100 mV
-120...+120 mV
-150...+150 mV
-200...+200 mV
-300...+300 mV
-500...+500 mV
-1000...+1000 mV
-1.0...+1.0 V
-1.5...+1.5 V
-2.0...+2.0 V
-3.0...+3.0 V
-5...+5 V
-10...+10 V
-15...+15 V
-20...+20 V
-30...+30 V
-50...+50 V
-100...+100 V

IN06 = 1...5 V
IN04 = 2...10 V

IN70
IN71
IN72
IN73
IN36
IN37
IN74
IN01
IN75
IN76
IN77

=
=
=
=
=
=
=
=
=
=
=

0...1.0 mA
0...1.5 mA
0...2.0 mA
0...3.0 mA
0...5 mA
0...10 mA
0...15 mA
0...20 mA
0...30 mA
0...50 mA
0...100 mA

IN83
IN84
IN85
IN86
IN33
IN34
IN87
IN35
IN88
IN89
IN90

=
=
=
=
=
=
=
=
=
=
=

-1.0...+1.0 mA
-1.5...+1.5 mA
-2.0...+2.0 mA
-3.0...+3.0 mA
-5...+5 mA
-10...+10 mA
-15...+15 mA
-20...+20 mA
-30...+30 mA
-50...+50 mA
-100...+100 mA

OUT01
OUT19 = 0...2.5 V
OUT05 = 0...5 V
OUT03 = 0...10 V

OUT15 = 0...5 mA
OUT16 = 0...10 mA
OUT01 = 0...20 mA

OUT20 = -2.5...+2.5 V
OUT13 = -5...+5 V
OUT14 = -10...+10 V

OUT21 = -5...+5 mA
OUT22 = -10...+10 mA
OUT23 = -20...+20 mA

OUT24 = 0.5...+2.5 V
OUT06 = 1...5 V
OUT04 = 2...10 V

OUT25 = 1...5 mA
OUT26 = 2...10 mA
OUT02 = 4...20 mA

OUT27 = 2.5...0 V
OUT11 = 5...0 V
OUT09 = 10...0 V

OUT28 = 5...0 mA
OUT29 = 10...0 mA
OUT07 = 20...0 mA

30
30 = 30 Hz
10K = 10 kHz

Factory calibration
certificate
/
NONE
= Without certificate
= With factory
calibration
certificate (fee)
YESPLUS = Factory
calibration
certificate with
5 measuring
points (fee)
NONE
YES

IN91 = 1...5 mA
IN92 = 2...10 mA
IN02 = 4...20 mA

Application example: Level measurement and active analog input card

MACX MCR-UI-UI-UP

IN

Level sensor
4.2

0...20mA

24V

4.1
5.2
5.1

OUT

50mV... 1000mV
1mA... 5mA

active

10mA... 100mA

3.2

3.1

GND

2.2
passive

1V... 100V

2.1

Power
24V ...230V AC/DC

1.2

1.1

Control system

Power
24V ...230V AC/DC

Application example: Shunt measurement and Inline terminal with analog input channels within an Inline station

MACX MCR-UI-UI-UP

IN
4.2

Shunt
resistor

mV

4.1

5.1

10mA... 100mA

active

3.2

3.1
AI2

5.2

OUT

50mV... 1000mV
1mA... 5mA

GND
1V... 100V

2.2
passive

2.1

Power
24V ...230V AC/DC

1.2

1.1

Battery

Power
24V ...230V AC/DC
IB IL AI 2/SF

(Information about automation solutions from Phoenix Contact is given in the AUTOMATION catalog or under www.phoenixcontact.com)

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

359

INTERFACE Analog
MACX Analog / MCR Analog
Configurable 3-way isolation
amplifiers

FL

Isolation

17,5

114,5

99

IN

U,I

U,I

OUT

MCR-C-UI-UI-DCI
POWER

Configurable 3-way isolation amplifiers with more than 225 signal


conversion functions

uPFz
Ex: U

Housing width 17.5

IN

3-way isolation
Configurable input and output signals
Alternatively limit frequency 30 Hz or
450 Hz

Pluggable screw
connection

The MCR-C-UI-UI-DCI 3-way


isolation amplifiers are used for electrical
isolation and conversion of standard analog
signals.
3-way isolation prevents different sensor
circuits interfering with each other and
thereby improves the quality of your
measuring circuit.
DIP switches enable the inputs and
outputs of the isolation amplifier to be
reconfigured, allowing more than 225 signal
conversions to be set.
The desired configuration of the input
and output signal can be stated in the order
(refer to the order key and the combination
table). If the customer order details are
incorrect or missing, the devices are
supplied with the standard configuration
(input signal 0...10 V, output signal 0...10 V).

PHOENIX CONTACT

AWG
24-14

MCR 3-way isolation amplifier, for electrical isolation of analog


signals,
with limit frequency (3 dB) 30 Hz
Order configuration
with limit frequency (3 dB) 30 Hz
Standard configuration
with limit frequency (3 dB) 450 Hz,
Order configuration
without GL and UL approval
Technical data
Input data
Input signal (configurable using the DIP switch)
Maximum input signal
Input resistance
Output data
Output signal (configurable using the DIP switch)
Maximum output signal
Load RB
General data
Supply voltage UB
Current consumption
Transmission error, max.
Temperature coefficient
ZERO / SPAN adjustment
Limit frequency (3 dB)
Step response (10-90%)
Test voltage input/output
Test voltage power supply/signal
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

7 OUT I
8 OUT U
9 GND 2

U,
U

Screw
M3

Description

GL

360

stranded
[mm2]
0.2-2.5
0.2-2.5

IN U/I 1
GND 1 2
GND 1 3

solid

OUT

10 +24V DC
11 GND 3
12 GND 3

Type

Order No.

MCR-C-UI-UI-DCI
MCR-C-UI-UI-DCI-NC
MCR-C-UI-UI-450-DCI

2810913
2810939
2810887

Pcs. /
Pkt.

1
1
1

U input
I input
0 ... 10 V, please indicate any different setting when ordering
30 V
50 mA
1 M
50
U output
I output
0 ... 10 V, please indicate any different setting when ordering
15 V
30 mA
10 k
500
MCR-C-UI-UI-DCI
MCR-C-UI-UI-450-DCI
18 V DC ... 30 V DC
18 V DC ... 30 V DC
< 30 mA (without load)
< 30 mA (without load)
0.1% (of end value)
0.1% (of end value)
0.0075%/K
0.0075%/K
2% / 2%
2% / 2%
30 Hz
450 Hz
11 ms
0.8 ms
1.5 kV (50 Hz, 1 min.)
1.5 kV (50 Hz, 1 min.)
1 kV (50 Hz, 1 min.)
1 kV (50 Hz, 1 min.)
IP20
IP20
-20C ... 65C
-20C ... 65C
Any
Any
Polyamide PA non-reinforced
Polyamide PA non-reinforced
CE compliant
Class I, Div. 2, Groups A, B, C, D
or non-hazardous locations
Germanischer Lloyd

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

CE compliant
-

INTERFACE Analog
MACX Analog / MCR Analog
Order key MCR-C-UI-UI-...-DCI (Standard configuration entered as example)
Output
Order No.

Factory calibration
certificate
/
NONE

Input
2810913

2810913 = MCR-C-UI-UI-DCI
2810887 = MCR-C-UI-UI-450DCI

IN03
IN01
IN02
IN03
IN05
IN06
IN13
IN14
IN15
IN16
IN17

=
=
=
=
=
=
=
=
=
=

0...20 mA
4...20 mA
0...10 V
0...5 V
1...5 V
-60...+60 mV
-100..+100 mV
-200...+200 mV
-300...+300 mV
-500...+500 mV

IN18
IN19
IN20
IN21
IN22
IN23
IN24
IN25
IN26
IN27
IN28

=
=
=
=
=
=
=
=
=
=
=

-1...+1 V
-2...+2 V
-2.5...+2.5 V
-5...+5 V
-10...+10 V
-20...+20 V
0...60 mV
0...100 mV
0...200 mV
0...300 mV
0...500 mV

IN29
IN30
IN31
IN32
IN33
IN34
IN35
IN36
IN37

=
=
=
=
=
=
=
=
=

0...1 V
0...2 V
0...2.5 V
0...20 V
-5...+5 mA
-10...+10 mA
-20...+20 mA
0...5 mA
0...10 mA

OUT03
OUT01
OUT02
OUT03
OUT05
OUT06
OUT13
OUT14
OUT15
OUT16

=
=
=
=
=
=
=
=
=

0...20 mA
4...20 mA
0...10 V
0...5 V
1...5 V
-5...+5 V
-10...+10 V
0...5 mA
0...10 mA

= Without certificate
= With factory
calibration
certificate (fee)
YESPLUS = Factory
calibration
certificate with
5 measuring
points (fee)
NONE
YES

Combination table for input and output signals

Input
0...60 mV
0...100 mV
0...200 mV
0...300 mV
0...500 mV
0...1 V
0...2 V
0...2.5 V
0...5 V
0...10 V
0...20 V
-60...+60 mV
-100 ...+100 mV
-200 ...+200 mV
-300 ...+300 mV
-500 ...+500 mV
-1...+1 V
-2...+2 V
-2.5...+2.5 V
-5...+5 V
-10...+10 V
-20...+20 V
0...5 mA
0...10 mA
0...20 mA
-5...+5 mA
-10...+10 mA
-20...+20 mA
1...5 V
4...20 mA

0...10 V
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Voltage output
-10...+10 V
0...5 V
-5...+5 V
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1...5 V
x
x
x
x
x
x
x
x
x
x
x

0...5 mA
x
x
x
x
x
x
x
x
x
x
x

x
x
x

x
x
x

x
x

Current output
0...10 mA 0...20 mA
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

4...20 mA
x
x
x
x
x
x
x
x
x
x
x

x
x
x

x
x

Application example: Level measurement

Level sensor

0...20mA

GND 1

MCR-C-UI-UI-DCI
ZERO

GND 1

SPAN

U/I

POWER

OUT
T

24V

POWER
(+)
24V

GND 3

11

GND 2

GND 3

12

10

24V

Mains voltage

0...10V

Control system

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

361

INTERFACE Analog
MACX Analog / MCR Analog
Configurable signal multiplier

99

17,5

Isolation

114,5

OUT1
FL

U,I
IN

U,I

U,I

OUT2

MCR-FL-C-UI-2UI-DCI
POWER

Signal multiplier with configurable input and two outputs

uPz
Ex: U

Housing width 17.5


OUT

4-way isolation
Configurable input and output signals
Balanced signal combinations

solid

The MCR-C-UI-2UI-DCI signal


multiplier is used for electrical isolation and
conversion of analog signals.
Module input, both outputs, and supply
are electrically isolated from one another.
Modules can therefore be used for electrical
isolation, signal conversion, and signal
amplification on site as well as near the
controller. A green power LED indicates
that supply voltage is present.
Each of the two outputs has one current
output and one voltage output which can be
used in parallel.
It is possible to switch between a signal
selected within the limits of the order key
or the signal conversions listed in the
configuration table, using DIP switches.
It is not necessary to calibrate after
reconfiguration because each transmission
type has already been calibrated and stored
in the device.
The desired configuration of the input
and output signal can be stated in the order
(refer to the order key and the combination
table). If the customer order details are
incorrect or missing, the devices are
supplied with the standard configuration
(input signal 0...20 mA, output signal
0...20 mA).

362

PHOENIX CONTACT

Pluggable screw
connection

stranded
[mm2]
0.2-2.5
0.2-2.5

OUT I2 1
OUT U2 2
GND 2 3

AWG
24-14

Screw
M3

A
D

IN I 4
IN U 5
GND 3 6

OUT

7 OUT I1
8 OUT U1
9 GND 1
+24V DC
GND 4
12 GND 4

10

11

D
IN

Description

Type

Order No.

MCR signal multiplier, for multiplying and electrical isolation of


analog signals,
Order configuration
Standard configuration

MCR-FL-C-UI-2UI-DCI
MCR-FL-C-UI-2UI-DCI-NC

2814854
2814867

Technical data
Input data
Input signal
Measuring range span
Maximum input signal
Input resistance
Output data
Output signal (configurable using the DIP switch)
Maximum output signal
Load RB
General data
Supply voltage UB
Current consumption
Transmission error, max.
Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Test voltage, input/output/supply
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

U input
0 V ... 12 V (freely selectable in
0.1 V steps)
Min. 4 V
30 V
200 k
U output
refer to the order key
15 V
10 k

Pcs. /
Pkt.

I input
0 mA ... 24 mA (freely selectable
in 0.1 mA steps)
Min. 8 mA
50 mA
50
I output
refer to the order key
35 mA
600

20 V DC ... 30 V DC
< 25 mA
0.15% (of end value), Typ. 0.05% (of end value)
< 0.015%/K, Typ. 0.0075%/K
30 Hz
12 ms
1.5 kV (50 Hz, 1 min.)
IP20
-25C ... 55C
Any
Polyamide PA non-reinforced
CE compliant
Class I, Div. 2, Groups A, B, C, D or non-hazardous locations

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

1
1

INTERFACE Analog
MACX Analog / MCR Analog
Order key MCR-FL-C-UI-2UI-DCI (Standard configuration entered as example)

Order No.
2814854

Input signal range (standard and special signals)


Initial value
Final value
/
0.0
/
20.0

Input signal
/
I
I = Current
U = Voltage

Output signal (standard signals)


Output 1
Output 2
/
OUT01
/
OUT01

0.0 = 0.0 mA
I : Freely selectable between
0.0...24.0 mA

20.0 = 20.0 mA
I : Freely selectable between
0.0...24.0 mA

U : Freely selectable between


0.0...12.0 mA

U : Freely selectable between


0.0...12.0 mA

OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT16

=
=
=
=
=
=
=

0...20 mA
4...20 mA
0...10 V
2...10 V
0...5 V
1...5 V
0...10 mA

OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT16

=
=
=
=
=
=
=

Factory calibration
certificate
/
NONE
= Without certificate
= With factory
calibration
certificate (fee)
YESPLUS = Factory
calibration
certificate with
5 measuring
points (fee)

0...20 mA
4...20 mA
0...10 V
2...10 V
0...5 V
1...5 V
0...10 mA

NONE
YES

Measuring range span min. 8.0 mA/4.0 V


Increment 0.1 mA /0.1 V

Ordering examples:
2814854

Input signal range (standard and special signals)


Initial value
Final value
/
5.3
/
13.3

I
I = Current

I = 5.3 mA

Output signal (standard signals)


Output 1
Output 2
/
OUT01
/
OUT01

= 13.3 mA

OUT01 = 0...20 mA

Factory calibration
certificate
/
NONE

OUT01 = 0...20 mA

NONE

= Without factory

NONE

= Without factory

Measuring range span 8.0 mA, i.e. order is possible.

2814854

U = Voltage

7.8

U = 7.8 V

11.8

U = 11.8 V

OUT01

OUT01 = 0...20 mA

OUT03

OUT03 = 0...10 V

NONE

Measuring range span 4.0 V, i.e. order is possible.

Combination table for input and output signals set with DIP switches

Input

0...20 mA 4...20 mA 0...10 mA

0...20 mA
4...20 mA
0...10 mA
2...10 mA
0...10 V
2...10 V
0...5 V
1...5 V

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

Output 1
0...10 V

0...5 V

1...5 V

2...10 V

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

0...20 mA 4...20 mA 0...10 mA


x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

Output 2
0...10 V

0...5 V

1...5 V

2...10 V

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

Application example: Level measurement with subsequent signal multiplication

Level sensor
0...20mA
24V

0...20mA

IN

OUT 2
I2

U2

GND 3

GND 2

POWER

MCR-FL-C-UI-2UI-DCI

POWER
+24V

U1

GND 4

11

GND 1

GND 4

12

OUT 1
I

10

Control system
0...10V
15m3

24V

Mains voltage

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

363

INTERFACE Analog
MACX Analog / MCR Analog
Standard signal 3-way isolation
amplifiers
99

Isolation

114,5

12,5

IN

U,I

U,I

OUT

MCR-C-...-DC
SL

POWER

3-way isolation amplifier

uPz

Housing width 12.5

IN

Processing standard signals


Fixed setting of input and output signals
3-way isolation
The MCR-C-...-DC 3-way isolation
amplifiers are used for electrical isolation
and conversion of standard analog signals.
The devices are electrically isolated from
each other in the input, output and supply
circuit.
The isolation amplifier allows electrical
isolation of the sensor circuit from the
evaluation circuit, thus also preventing
reciprocal interference between several
sensor circuits.
As a result of the 3-way isolation, the
modules can be used both on site or close
to the control unit for signal conversion and
electrical isolation, as well as on the
transmission route to bridge high load
resistances.

Pluggable screw
connection

stranded
[mm2]
0.2-2.5
0.2-2.5

Description

PHOENIX CONTACT

AWG
24-14

5 OUT I/U
6 GND 2

U,

Screw
M3
7 +20...30V
8 GND 3

Input signal

Output signal

MCR 3-way isolation amplifier, for electrical isolation of analog


signals,
0 ... 10 V
0 ... 20 mA
0 ... 10 V
4 ... 20 mA
0 ... 20 mA
4 ... 20 mA
4 ... 20 mA
0 ... 20 mA
4 ... 20 mA
0 ... 10 V
0 ... 20 mA,
0 ... 20 mA,
4 ... 20 mA
4 ... 20 mA
0 ... 20 mA,
0 ... 10 V,
-20 ... 20 mA
-10 ... 10 V
0 ... 10 V,
0 ... 10 V,
-10 ... 10 V
-10 ... 10 V

Pcs. /
Pkt.

Type

Order No.

MCR-C-U-I- 0-DC
MCR-C-U-I- 4-DC
MCR-C-I-I-04-DC
MCR-C-I-I-40-DC
MCR-C-I-U- 4-DC
MCR-C-I-I-00-DC

2814472
2814537
2814540
2814524
2814511
2814508

5
5
5
5
5
5

MCR-C-I-U- 0-DC

2814498

MCR-C-U-U-DC

2814469

Technical data
Input data
Input signal

U input
0 ... 10 V / -10 ... 10 V

Maximum input signal


Input resistance
Output data
Output signal
Maximum output signal
Load RB
Linear transmission range (in reference to the output range end
value)

30 V
200 k
U output
0 ... 10 V / -10 ... 10 V
15 V
> 10 k
-10% ... 110%
-110% ... 110% (bipolar signals)

General data
Supply voltage UB
Current consumption
Transmission error, max.

20 V DC ... 30 V DC
< 15 mA (without load)
0.3% (of end value), Typ. < 0.2% (of end value)

Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Test voltage, input/output/supply
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity

364

IN I/U 1
GND 1 2

solid

OUT

< 0.015%/K
30 Hz
11 ms
1.5 kV (50 Hz, 1 min.)
-25C ... 60C
Any
Polyamide PA non-reinforced
CE compliant

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

I input
0 ... 20 mA / 4 ... 20 mA
-20 ... 20 mA
50 mA
50
I output
0 ... 20 mA / 4 ... 20 mA
30 mA
500
-5% ... 105%

INTERFACE Analog
MACX Analog / MCR Analog
Repeater power supply HART

12,5

POWER

114,5

Isolation

99

OUT

IN
SL

MACX MCR-SL-RPSSI-I
POWER

Repeater power supply for supplying 2 and 3-conductor transmitters


with HART transmission

Housing width 12.5


IN

Input 0/4...20 mA (feeding or non-feeding)


Output 0/4...20 mA (active or passive)
HARTable
Up to SIL 2 according to EN 61508
Galvanic 3-way isolation
Installation in zone 2 permissible
Power supply via DIN rail connector
possible

The repeater power supply MACX


MCR-SL-RPSSI-I has been designed for
the operation of measuring transducers and
mA current sources.
The 2-wire measuring transducers are
supplied with power, and analog 0/4...20 mA
measured values are transferred from the
field. 4-wire measuring transducers and mA
current sources can be operated via a nonfeeding input. The module output can be
operated actively or passively.
The analog measured value can be
overlayed with digital (HART)
communication signals and transmitted
bidirectionally. An additional resistance can
be switched in the output circuit in order to
increase the HART impedance in low-ohmic
systems using a terminal point.
Receptacles are integrated into the
COMBICON connectors for connecting
the HART communicators.

OUT
4.2
4.1

Connection data
Screw connection
Torque
Spring-cage conn.

solid

stranded
[mm2]
AWG
0.2-2.5
0.2-2.5 24-14
0.5...0.6 Nm
0.2-1.5
0.2-1.5 24-16

5.2

Screw
M3

5.1

Source

4.2

3.2

4.1

3.1

Sink

+
-

2.2

5.2
250 W

5.1

2.1

1.2

GND

1.1

+24V

ME 6,2 TBUS-...

Description

Type

Order No.

MACX MCR-SL-RPSSI-I
MACX MCR-SL-RPSSI-I-SP

2865955
2924207

Pcs. /
Pkt.

MCR repeater power supply with HART protocol


Screw connection
Spring-cage conn.
Technical data
Input data
Input signal
Transmitter supply voltage
Voltage drop
Output data
Output signal

0 mA ... 20 mA / 4 mA ... 20 mA
> 16 V (at 20 mA)
< 3.5 V (in input isolation amplifier operation)
0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
0 mA ... 20 mA (passive, ext. source voltage 14...26 V)
4 mA ... 20 mA (passive, ext. source voltage 14...26 V)
< 600
< 20 mVrms

Load
Output ripple
General data
Supply voltage range
Current consumption
Power dissipation
Temperature coefficient
Step response (10-90%)
Transmission error, typical
Transmission error, max.
Under/overload range
Electrical isolation

19.2 V DC ... 30 V DC
< 60 mA (for 24 V DC)
< 1.1 W (at 24 V DC / 20 mA)
< 0.01%/K
< 600 s (for jump 4 mA ... 20 mA)
< 0.05% (of end value)
< 0.1% (of end value)
as per NE 43
Input/output/power supply

Accessories:
Information about the supply and error evaluation module as well as
about the DIN rail connectors and marking material can be found
from page 445.

Input/output
Input/power supply
Ambient temperature range
Status indication
SMART communication
Signal bandwidth
Protocols supported
Housing material
Conformance / approvals
Conformity
ATEX
IECEx
UL, USA / Canada
Functional safety (SIL)

1
1

2.5 kV (50 Hz, 1 min., test voltage)


300 Vrms (rated insulation voltage, surge voltage category II;
pollution degree 2, safe isolation as per EN 61010, EN 50178)
375 V (peak value in accordance with EN 60079-11)
375 V (peak value in accordance with EN 60079-11)
-20C ... 60C (any mounting position)
LED green (supply voltage)
Yes
As per HART specifications
HART
Polyamide (PA 6.6)
CE-compliant, additionally EN 61326
X II 3 G Ex nA nL II T4
Ex nA nL II T4
UL applied for
SIL 2 according to EN 61508

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

365

INTERFACE Analog
MACX Analog / MCR Analog
Repeater power supply HART

17,5

POWER

114,5

Isolation

99

OUT

IN
SL

MACX MCR-SL-RPSSI-I-UP
POWER

Repeater power supply for supplying 2 and 3-conductor transmitters


with HART transmission, with long range supply

Housing width 17.5


IN

Input 0/4...20 mA (feeding or non-feeding)


Output 0/4...20 mA (active or passive)
HARTable
Up to SIL 2 according to EN 61508
Galvanic 3-way isolation
Installation in zone 2 permissible
Long range supply of
19.2 V AC/DC ... 253 V AC/DC

The repeater power supply MACX


MCR-SL-RPSSI-I-UP has been designed
for the operation of measuring transducers
and mA current sources.
The 2-wire measuring transducers are
supplied with power, and analog 0/4...20 mA
measured values are transferred from the
field. 4-wire measuring transducers and mA
current sources can be operated via a nonfeeding input. The module output can be
operated actively or passively.
The analog measured value can be
overlayed with digital (HART)
communication signals and transmitted
bidirectionally. An additional resistance can
be switched in the output circuit in order to
increase the HART impedance in low-ohmic
systems using a switch on the front of the
device.
The power supply has been designed as a
long range supply (UP).
Receptacles are integrated into the
COMBICON connectors for connecting
the HART communicators.

4.3
4.2

Connection data
Screw connection
Torque
Spring-cage conn.

stranded
[mm2]
AWG
0.2-2.5
0.2-2.5 24-14
0.5...0.6 Nm
0.2-1.5
0.2-1.5 24-16

4.1

solid

4.1

Source

250 W

3.2

S1

4.3
4.2

3.1

1.2
1.1

Description

Sink

24 ... 230
V AC/DC

Type

Order No.

MACX MCR-SL-RPSSI-I-UP
MACX MCR-SL-RPSSI-I-UP-SP

2865968
2924210

Pcs. /
Pkt.

MCR repeater power supply with HART protocol


Screw connection
Spring-cage conn.
Technical data
Input data
Input signal
Transmitter supply voltage
Voltage drop
Output data
Output signal

0 mA ... 20 mA / 4 mA ... 20 mA
> 16 V (at 20 mA)
< 3.5 V (in input isolation amplifier operation)
0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
0 mA ... 20 mA (passive, ext. source voltage 14...26 V)
4 mA ... 20 mA (passive, ext. source voltage 14...26 V)
0 V ... 5 V (internal resistance, 250 , 0.1%)
1 V ... 5 V (internal resistance, 250 , 0.1%)
< 600 (I output)
< 20 mVrms

Load
Output ripple
General data
Supply voltage range

24 V AC/DC ... 230 V AC/DC (-20%/+10%, 50/60 Hz)

Current consumption
Power dissipation
Temperature coefficient
Step response (10-90%)
Transmission error, typical
Transmission error, max.
Under/overload range
Electrical isolation

< 75 mA (for 24 V DC)


< 1.8 W
< 0.01%/K
< 600 s (for jump 4 mA ... 20 mA)
< 0.05% (of end value)
< 0.1% (of end value)
as per NE 43
Input/output/power supply

Ambient temperature range


Status indication
SMART communication
Signal bandwidth
Protocols supported
Housing material
Conformance / approvals
Conformity
ATEX
IECEx
UL, USA / Canada
Functional safety (SIL)

PHOENIX CONTACT

4.2

Screw
M3

Input/output
Input/power supply

366

3.3

S2

250 W

OUT

2.5 kV (50 Hz, 1 min., test voltage)


300 Vrms (rated insulation voltage, surge voltage category II;
pollution degree 2, safe isolation as per EN 61010, EN 50178)
375 V (peak value in accordance with EN 60079-11)
375 V (peak value in accordance with EN 60079-11)
-20C ... 60C (any mounting position)
LED green (supply voltage)
Yes
As per HART specifications
HART
Polyamide (PA 6.6)
CE-compliant, additionally EN 61326
X II 3 G Ex nA nL II T4
Ex nA nL II T4
UL applied for
SIL 2 according to EN 61508

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

1
1

INTERFACE Analog
MACX Analog / MCR Analog
Configurable loop-powered isolator

17,5

114,5

99

Isolation

FL

IN

U,I

POWER

OUT

MCR-CLP-UI-I-4
Loop-powered isolator with a configurable input

uPz
Ex: U

Housing width 17.5

IN

No separate voltage supply


Electrically isolated input
Configurable input
4...20 mA output
Zero/span adjustment ( 2%)

OUT

IN U/I 1

solid

Pluggable screw
connection

The MCR-CLP-UI-I-4 loop-powered


isolator is used for electrical isolation and
signal conditioning in analog signal circuits.
On the input side, more than 25 different
signal ranges can be set using DIP switches.
On the output side, the isolator is
operated in a 4...20 mA current loop, which
simultaneously provides the power supply
for the module necessary for signal
conversion.
The desired configuration of the input
signal must be specified in the order (refer
to the order key). If customer order details
are missing or faulty, devices with the
standard configuration are supplied (input
signal 4...20 mA).

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

GND

GND

U,

DC
DC

7 (+) 8...30VDC
8 OUT I
9 NC

U,

Description

Type

Order No.

MCR loop-powered isolator, for electrical isolation of analog


signals,
Order configuration
Standard configuration

MCR-CLP-UI-I-4
MCR-CLP-UI-I-4-NC

2814058
2814252

Technical data
Input data
Input signal (configurable using the DIP switch)
Maximum input signal
Input resistance
Output data
Output signal
Maximum output signal
Load RB

1
1

U input
I input
4 ... 20 mA, please indicate any different setting when ordering
30 V
50 mA
1 M
50
4 ... 20 mA
35 mA
800 (at UB = 24 V; otherwise: (UB - 8 V) / 20 mA)

General data
Supply voltage UB
Transmission error, max.
Temperature coefficient
ZERO / SPAN adjustment
Limit frequency (3 dB)
Step response (10-90%)
Test voltage input/output
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

Order key MCR-CLP-UI-I-4 (Standard configuration entered as example)

Pcs. /
Pkt.

8 V DC ... 30 V DC
0.1% (of end value), Typ. 0.05%
0.01%/K, Typ. 0.005%/K
2% (of end value) / 2% (of end value)
30 Hz
11 ms
1.5 kV (50 Hz, 1 min.)
-25C ... 65C
Any
Polyamide PA non-reinforced
CE compliant
Class I, Div. 2, Groups A, B, C, D or non-hazardous locations

Level measurement
+

Order No.
2814058

Input
/

Factory calibration
certificate
/
NONE

IN02
IN18
IN19
IN21
IN22
IN23
IN24
IN25
IN26
IN27
IN28

= -1...+1 V
= -2...+2 V
= -5...+5 V
= -10...+10 V
= -20...+20 V
= 0...60 mV
= 0...100 mV
= 0...200 mV
= 0...300 mV
= 0...500 mV

IN29
IN30
IN32
IN33
IN34
IN35
IN36
IN37

= 0...1 V
= 0...2 V
= 0...20 V
= -5...+5 mA
= -10...+10 mA
= -20...+20 mA
= 0...5 mA
= 0...10 mA

= Without certificate
= With factory
calibration
certificate (fee)
YESPLUS = Factory
calibration
certificate with
5 measuring
points (fee)
NONE
YES

0...20mA

U B = 24V
1

IN U/I

GND

GND

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

MCR-CLP-U-I-4
ZERO

= 0...20 mA
= 4...20 mA
= 0...10 V
= 0...5 V
= 1...5 V
= -60...+60 mV
= -100..+100 mV
= -200...+200 mV
= -300...+300 mV
= -500...+500 mV

24V

SPAN

IN01
IN02
IN03
IN05
IN06
IN13
IN14
IN15
IN16
IN17

Level sensor

+UB

NC

24V

Mains
voltage

4...20mA

Active PLC input


card

PHOENIX CONTACT

367

INTERFACE Analog
MACX Analog / MCR Analog
Single-channel passive isolator with
safe isolation
99

Isolation

114,5

12,5

IN

OUT

MCR-SL-1CLP-I-I-00-4KV
Passive isolator with safe isolation, 1-channel

SL

uPz

Housing width 12.5

Electrical isolation without additional


auxiliary power supply
Current signals 0(4)...20 mA
Safe isolation

IN

Pluggable screw
connection

The MCR-SL-1CLP-I-I-00-4KV passive


isolators are used for electrical isolation of
analog current standard signals. The
components guarantee electrical isolation
between the control electronics and
process peripherals. Furthermore,
interference signal parts above 75 Hz are
effectively suppressed.
Input and output circuits require no
additional auxiliary power. This is obtained
by the modules from the input signal.
When passive isolators are used, one
must make sure that the current sourcing
voltage of the measuring transducer UB is
sufficient to drive the maximum current of
20 mA via the passive isolator with the
voltage drop UV = 2.5 V and the load RB.
This means:
UB UE = 2.5 V + 20 mA x RB

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

Description

5 (+) 20mA
6 (-) GND

(+) 0-20mA 1
(-) GND 2

Type

Order No.

MCR-SL-1CLP-I-I-00-4KV

2814841

Technical data
Input data
Input signal
Voltage drop
Response current
Maximum input current
Maximum input voltage
Input voltage limitation
Output data
Output signal
Maximum output signal
Load RB
Ripple
General data
Transmission error, max.
Additional error per 100 load
Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Test voltage input/output
Protection against electric shock

UE

0 ... 20 mA / 4 ... 20 mA
50 mA
1375 (at I = 20 mA output signal)
< 5 mV (rms)
0.1% (of end value)
0.02% (of measured value / 100 load)
0.002%/K (of measured value / 100 load)
< 75 Hz (at I = 20 mA and maximum load)
5 ms (with 500 load)
4 kV (50 Hz, 1 min.)
Increased insulation acc. to DIN EN 61 010 part 1 and safe isolation
acc. to VDE 0100 part 410 along the lines of VDE 0106 part 101 up
to 300 V AC/DC for surge voltage category II and pollution degree 2
between all isolated distances.
-10C ... 70C
Any
Polyamide PA non-reinforced
CE compliant

I
MCR-1CLP

2 5

RB

The diagram shows input voltage UE in relation to load RB taking


into account voltage failure UV.
If you know the load, the minimum voltage the sensor must
supply in order to drive the maximum current of 20 mA via the
loop-powered isolator and the load can be read off on the Y-axis.

2 0
1 5
1 0
5
0

368

PHOENIX CONTACT

0 ... 20 mA / 4 ... 20 mA
2.5 V (at I = 20 mA)
< 50 A
50 mA (100 mA overload)
30 V (30 V overload)
33 V 5% (with Zener diode)

Input voltage depending on the load at IA = 20 mA


U V = 2,5 V

Pcs. /
Pkt.

MCR passive isolator, for electrical isolation of current signals


without auxiliary power

Ambient temperature (operation)


Assembly
Housing material
Conformance / approvals
Conformity

UB

OUT

solid

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

2 0 0

4 0 0

6 0 0

8 0 0

1 0 0 0

INTERFACE Analog
MACX Analog / MCR Analog
Single or multi-channel loop-powered
isolator
99

Isolation

114,5

12,5

IN

OUT

MCR-1CLP-I-I-00
Passive isolator, 1, 2 or 4-channel

SL

uPz

Housing width 12.5

Electrical isolation without additional


auxiliary power supply
Current signals 0(4)...20 mA
Alternatively 1, 2 or 4-channel version

IN

Pluggable screw
connection

The MCR-SL-...CLP-I-I-00 passive


isolators are used for electrical isolation of
analog current standard signals. The
components guarantee electrical isolation
between the control electronics and
process peripherals. Furthermore,
interference signal parts above 75 Hz are
effectively suppressed.
Input and output circuits require no
additional auxiliary power. This is obtained
by the modules from the input signal.
When passive isolators are used, one
must make sure that the current sourcing
voltage of the measuring transducer UB is
sufficient to drive the maximum current of
20 mA via the passive isolator with the
voltage drop UV = 2.5 V and the load RB.
This means:
UB UE = 2.5 V + 20 mA x RB

UB

stranded
[mm2]
0.2-2.5
0.2-2.5

OUT

solid

AWG
24-14

Screw
M3

5 (+) 20mA
6 (-) GND

(+) 0-20mA 1
(-) GND 2

Description

Type

Order No.

MCR passive isolator, for electrical isolation of current signals


without auxiliary power
1-channel
12.5 mm wide
2-channel
12.5 mm wide
4-channel
22.5 mm wide

MCR-1CLP-I-I-00
MCR-2CLP-I-I-00
MCR-4CLP-I-I-00

2814016
2814029
2814045

Technical data
Input data
Input signal
Voltage drop
Response current
Maximum input current
Maximum input voltage
Input voltage limitation
Output data
Output signal
Maximum output signal
Load RB
Ripple
General data
Transmission error, max.
Additional error per 100 load
Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Test voltage input/output
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity

Pcs. /
Pkt.

1
1
1

0 ... 20 mA / 4 ... 20 mA
2.5 V (at I = 20 mA)
< 50 A
50 mA (100 mA overload)
30 V (30 V overload)
33 V (with Zener diode)
0 ... 20 mA / 4 ... 20 mA
50 mA
1375 (at I = 20 mA output signal)
< 5 mV (rms)
0.1% (of end value)
0.02% (of measured value)
0.002%/K (of measured value / 100 load)
< 75 Hz
5 ms (with 500 load)
510 V (50 Hz, 1 min.)
-10C ... 70C
Any
Polyamide PA non-reinforced
CE compliant

Flow measurement
U V = 2,5 V

I
I

UE

I
I
MCR-1CLP

Magnetic inductive flow gauge

RB

24V

0...20mA
0...20mA
1

GND 1

MCR-1CLP-I-I-00
IN

GND 2

OUT

Control system

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

369

INTERFACE Analog
MACX Analog / MCR Analog
Programmable Temperature
Transducers

FL

U,I
IN

17,5

114,5

Temperature

99

OUT

MCR-T-UI-E
POWER

Programmable temperature transducers for


resistance thermometers and thermocouples

uPFz
Ex: U

Housing width 17.5

IN

For resistance thermometers and


thermocouples
Freely programmable via
MCR-PI-CONF-WIN
Optional with electrical isolation

1
2
solid

Pluggable screw
connection

The programmable MCR-T-UI


temperature transducers convert
temperature signals from resistance
thermometers and thermocouples as well
as from sensors with linear mV
characteristic curves into standard analog
signals.
As an option, two thermocouples can be
connected to measure the differential
temperature.
A downstream analog stage converts the
signal, electrically isolated as an option, into
0(4)...20 mA, 0...(5)10 V, (5)10 V or its
inverse signals.
The MCR-T modules also have an
electronic switching output (PNP transistor
output 100 mA/24 V).
The transmission behavior of the
temperature transducer is stated in the
order or set with the configuration
software MCR/PI-CONF-WIN, refer to
page 389.
The MCR-T modules are delivered
unconfigured or with order-specific
configuration on the basis of the order key.

stranded
[mm2]
0.2-2.5
0.2-2.5

Screw
M3

4
NC

NC

8
9
10

=
=

(+) 24VDC

11

SP

12

(-) GND

Type

Order No.

MCR-T-UI-E
MCR-T-UI-E-NC
MCR-T-UI
MCR-T-UI-NC

2814113
2814126
2814090
2814100

Pcs. /
Pkt.

MCR temperature transducers, for resistance thermometers and


thermocouple sensors, with electrical isolation of input/output and
input/supply voltage
Order configuration
Standard configuration
Order configuration, without electrical isolation
Standard configuration, without electrical isolation
Technical data
Input data
Resistance thermometers
Thermocouple sensors
Resistor
Voltage
Temperature range
Sensor input current
Output data
Output signal
Maximum output signal
Resolution D/A
Load RB
Ripple
Output signal with open circuit
Measuring range overrange/underrange
Switching output

Cold point errors


Temperature coefficient
Test voltage input/output
Test voltage input/power supply
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada
GL

PHOENIX CONTACT

AWG
24-14

Description

General data
Supply voltage UB
Current consumption
Transmission error, max.

370

OUT

1
1
1
1

Pt, Ni, Cu sensors : 2, 3, 4-wire


U, T, L, J, E, K, N, S, R, B, C, W, HK
0 ... 8000 (freely adjustable)
-20 mV ... 2400 mV (freely adjustable)
(Depending on sensor type used)
250 A (resistance thermometer)
U output
I output
0 ... 5 V / 0 ... 10 V
0 ... 20 mA / 4 ... 20 mA
-5 ... 5 V / -10 ... 10 V
12 V
24 mA
12 Bit
12 Bit
10 k
500
< 20 mVPP
-12 V ... 12 V
0 A ... 24 mA
-12 V ... 12 V
0 A ... 24 mA
Transistor output, pnp
Can carry a load of 100 mA, switches supply voltage (not protected
against short circuit); locked in case of order-specific configuration,
otherwise freely programmable through MCR/PI-CONF-WIN

18 V DC ... 30 V DC
60 mA, Typ. 40 mA
0.1% (of final value, 6 mV or 12 A at output)
3 K, Typ. 1.5 K
0.01%/K, Typ. 0.005%/K
1 kV (50 Hz, 1 min.)
1 kV (50 Hz, 1 min.)
-20C ... 65C
Any
Polyamide PA non-reinforced
CE compliant
Class I, Div. 2, Groups A, B, C, D or non-hazardous locations
Germanischer Lloyd

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Order key MCR-T-UI(-E)/... (Standard configuration entered as example)
Sensor type
Order No.
2814113

PT100

Refer to
tables under
"Sensor
type"

2814113 =
MCR-T-UI-E
2814090 =
MCR-T-UI

Input characteristic curve

Connection method

D = DIN
S = SAMA (see table)

3
2
3
4
0

0 = At Ni1000 (Landis&Gyr),
Cu10, Cu50, Cu53,
KTY81-110,
Thermocouple,
Resistor,
Potentiometer,
Voltage

= 2-wire
= 3-wire
= 4-wire
= For
Thermocouple,
Resistor,
Potentiometer,
Voltage

At 0 mA
(e.g.
-200.0C)

At 20 mA
(e.g.:
+850.0C)

=
=
=
=
=

C
F
V
O
P

C
F
mV

OUT01
OUT02
OUT03
OUT05
OUT13
OUT14

Thermocouples

Resistance thermometers
Sensor
type 1)

Standard
Measuring
(Input charac- range
teristic curve)

Smallest
measuring
range span

PT...
NI...
Ni1000
CU10
CU50
CU53
KTY81
KTY84

DIN/SAMA
-200C ... 850C
DIN/SAMA
-60C ... 180C
Landis & Gyr -50C ... 160C
SAMA
-70C ... 500C

-50C ... 200C

-50C ... 180C


Philips
-55C ... 150C

-40C ... 300C

Thermocouple

Measuring range

U
T
L
J
E
K
N
S
R
B
C
W
HK

Cu-CuNi
Cu-CuNi
Fe-CuNi
Fe-CuNi
NiCr-CuNi
NiCr-Ni
NiCrSi-NiSi
Pt10Rh-Pt
Pt13Rh-Pt
Pt30Rh-Pt6Rh

-200C ...
-200C ...
-200C ...
-210C ...
-226C ...
-200C ...
-200C ...
-50C ...
-50C ...
500C ...
-18C ...
-18C ...
-200C ...

Temperature ranges in accordance with IEC 60751/EN 60751 or


DIN 43760 SAMA RC 21-4-1966 in 2, 3 or 4-wire technology.
1) Note: Pt sensors in increments of 10, 20, ...100 and
100, 200, ...1000, 2000.
KTY81 = KTY81-110; KTY84 = KTY84-130.

2)

2)
2)
2)
2)
2)
2)
2)

=
=
=
=
=
=

0...20 mA
4...20 mA
0...10 V
0...5 V
-5...+5 V
-10...+10 V

Factory calibration
certificate
/
NONE

N = Normal
I = Inverse

= Without certificate
= With factory
calibration
certificate (fee)
YESPLUS = Factory
calibration
certificate with
5 measuring
points (fee)
NONE
YES

Resistors, potentiometers, mV-voltages

Sensor
type

0.4 K
0.4 K
0.4 K
0.4 K
0.4 K
0.4 K
0.4 K
0.4 K

Output characteristic
curve

Unit of mea- Output


surement
/
C
/
OUT02

Measuring range:
Start
End
/
-200.0
/
+850.0

Smallest
measuring
range span

600C
400C
900C
1200C
1000C
1372C
1300C
1768C
1768C
1820C
2316C
2316C
800C

Sensor
type

>1K
>1K
>1K
>1K
>1K
>1K
>1K
>4K
>4K
> 10 K
>4K
>4K
>1K

Input

Measuring range

Smallest
measuring
range span

RES

Resistance

0 ... 8000
(2-wire)

POT

Potentiometers
(max. 8 k)

0 ... 100%
(3-wire)

0.2%

V01

Voltage

-20 mV ...+2400 mV

2 mV

Conversion aid for temperature from C to F:


9

T [F] = T [C] + 32
5

2)

Thermocouples as per IEC 60584/EN 60584.


Further types and characteristic curves on request.

Further types and characteristic curves on request.

Order examples with various input versions:


Resistance thermometers

2814113 /

PT100

-200.0

+850.0

OUT02

NONE

(Configuration for 3-conductor PT 100 sensor; according to DIN from -200.0C to +850.0C with a 4...20 mA output characteristic)
Thermocouple

2814113 /

-346

+2192

OUT02

NONE

OUT03

NONE

OUT05

NONE

OUT02

NONE

(Configuration for thermocouple type J from -346F to +2192F with 20...4 mA output characteristic curve)
Voltage

2814113 /

V01

-10

1200

(Configuration for voltage input from -10 mV to +1200 mV with 10...0 V output characteristic curve)
Resistance

2814113 /

RES

7500

(Configuration for connecting a resistor varying between 0 and 7500 . The output signal is 0...5 V.)

(2-wire connection)
Potentiometers

2814113 /

(3-wire connection)

POT

10

90

(Configuration for connecting a 3-conductor potentiometer, whereby 10 90% of the range is used. The output signal is 420 mA)

Application examples:
Resistance thermometer: 2-conductor connection
method

Resistance thermometer: 3-wire connection method

R L1
1

R,

R L2

MCR-T-UI-E
Mode Power

7 10

+24 V DC
GND

R L1
MCR-T-UI-E

R L2

9 12

OUT I
GND

R L3

Output: Current signals 0(4)...20 mA


Application:
For short distances (< 10 m)
The following should be paid attention to:
Cable resistances RL1 and RL2 are incorporated in the
measurement result directly and falsify the result accordingly
(example Pt 100. 0.385 = 1 K).
A compensation of 5% is possible.

10
8

2
Mode Power

+24 V DC
GND

R L2
R L3

9 12

OUT U
GND

Thermocouple: Absolute temperature measurement

MCR-T-UI-E

10

11

2
3

Mode Power

+24 V DC
GND

9 12

SP

Output:
voltage signal 0...(5)10 V, (5)10 V

Application:
For large distances between the PT 100 sensor and the
MCR module (RL1, RL2, RL3 25 ).
The following should be paid attention to:
The value of all cable resistances must be exactly the same
in order to balance out the sensor cable resistances
(RL1 = RL2 = RL3)

Potentiometer

Resistance thermometer: 4-conductor connection


method

R L1

R L4

Output: Switching output

Application;
For long distances between a PT 100 sensor and the
MCR module and different cable resistances
(RL1 RL2 RL3 RL4)
The following should be paid attention to:
The cable resistance (RL2 + RL4) must not exceed a value
of 50 .

Thermocouple: Differential temperature measurement

R L1
1

MCR-T-UI-E

R L2

7 10
8 11

Mode Power

+24 V DC
GND

mV / TC

9 12

+
-

MCR-T-UI-E
Mode Power

OUT I
GND

7 10
8 11

+24 V DC
GND

9 12

TC
TC

Application:
Connecting a thermocouple or an mV signal.
Note:
Activate cold junction compensation for the device with
thermocouple measurements.

+
-

MCR-T-UI-E

7 10
8 11

2
6

Mode Power

+24 V DC
GND

9 12

OUT I
GND

OUT I
GND

Application:
For short distances and slow changes!
The following should be paid attention to:
Cable resistances RL1 and RL2 are incorporated in the
measurement result directly and falsify the result accordingly.
A compensation of 5% is possible.

+
-

Application:
Differential temperature measurement using thermocouples.
Switch off the cold junction compensation of the device.

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

371

INTERFACE Analog
MACX Analog / MCR Analog
Configurable temperature transducer
for Pt 100

FL

Temperature

17,5

114,5

99

IN

U,I

OUT

PT100

MCR-PT100-...(-DC)

POWER

Configurable temperature transducer for Pt 100, optionally with


electrical isolation

uPz

Housing width 17.5

IN

Temperature range adjustable via DIP


switch
ZERO/SPAN adjustment
Open circuit detection
Alternatively with galvanically isolated
supply voltage

1
2
stranded
[mm2]
0.2-2.5
0.2-2.5

Pluggable screw
connection

AWG
24-14

Screw
M3

2810337
2810311 = MCR-PT100-U-DC
2810337 = MCR-PT100-I-DC
2810340 = MCR-PT100-U
2810353 = MCR-PT100-I

372

PHOENIX CONTACT

3 = 3-wire
4 = 4-wire

OUT U/I

7
8

GND 1

9
=

Shield 5
Shield 6

10

(+) 24VDC

11

GND 2

12

GND 2

Power
MM

Description

Type

Order No.

MCR-PT100-U-DC
MCR-PT100-I-DC
MCR-PT100-U
MCR-PT100-I

2810311
2810337
2810340
2810353

Output: 0..0.10 V
Output: 0...(4)20 mA
Output: 0...10 V, without electrical isolation
Output: 0...(4)20 mA, without electrical isolation
Technical data
Input data
Resistance thermometers
Temperature range
Sensor input current
Output data
Output signal
Maximum output signal
Load RB
Output signal with open circuit
General data
Supply voltage UB
Current consumption
Transmission error, max.
Temperature coefficient
ZERO / SPAN adjustment
Step response (10-90%)
Test voltage power supply/signal
Ambient temperature (operation)
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

Temperature range
/
TR01
TR02
TR03
TR04
TR05
TR06
TR07
TR08

=
=
=
=
=
=
=
=

Pcs. /
Pkt.

MCR temperature transducer, for Pt 100 temperature sensors


with 2, 3, 4-wire technology with electrically isolated supply voltage

TR05
-50...+50C
-50...+100C
-50...+150C
-50...+250C
0...100C
0...150C
0...200C
0...300C

Output
/

OUT02
OUT01 = 0...20 mA
OUT02 = 4...20 mA
With the devices:
2810311 MCR-PT100-U-DC
2810340 MCR-PT100-U
The output signal is 0...10 V. No details
are necessary.

1
1
1
1

Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-wire


0C ... 300C (0 ... 100/150/200/300) /
-50C ... 250C (-50 ... 50/100/150/250)
Approx. 1 mA
U output
I output
0 ... 10 V
0 ... 20 mA / 4 ... 20 mA
15 V
30 mA
10 k
500
> 11 V
> 22 mA
...-U-DC
...-I-DC
...-U
...-I
20 ... 30 V DC 20 ... 30 V DC 20 ... 30 V DC 20 ... 30 V DC
35 mA
60 mA
20 mA
45 mA
0.4% (of end value)
0.02%/K
5% / 5%
11 ms
750 V AC (50 Hz, 1 min.)
-20C ... 65C
Polyamide PA non-reinforced
CE compliant
cULus

Order key MCR-PT100-...(-DC) (Standard configuration entered as example)


Connection
method
/
3
2 = 2-wire

U
U

solid

The MCR-PT100 temperature


transducers convert the measured values of
the Pt 100 sensors (IEC 60751/ EN 60751)
into electrically standardized analog signals.
The possible connection methods
(2, 3 or 4-wire connection), the various
temperature spans and the current outputs
(0...20 or 4...20 mA) can be selected by
means of DIP switches.
The calibration potentiometers are
accessible from the front and offer the
additional possibility of undertaking a
measuring section alignment (ZERO/SPAN).
The desired configuration must be
specified in the order (refer to the order
key). If the customer order details are faulty
or missing, the devices are supplied with the
standard configuration (3-wire connection,
0...100C, output signal 0...10 V or
4...20 mA).

Order No.

OUT

Factory calibration
certificate
/
NONE
NONE = Without certificate
YES
= With factory
calibration
certificate (fee)
YESPLUS = Factory
calibration
certificate with
5 measuring
points (fee)

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Temperature relay for Pt 100

99

Temperature

114,5

12,5

IN

OUT
PT100

MCR-SL-PT100-SP

POWER

SL

Temperature relay for Pt 100

uPz

Housing width 12.5

IN

Switching point in the temperature range


from -100C ... +700C freely selectable
Changeover relay output
Electrical isolation
Adjustable switch hysteresis

solid

Pluggable screw
connection

stranded
[mm2]
0.2-2.5
0.2-2.5

Pt 100
AWG
24-14

GND 4

Description

Technical data
Input data
Resistance thermometers
Temperature range
Sensor input current
Switching output
Contact type
Contact material
Max. switching current
Operate delay time
Off delay time
Switching hysteresis

General data
Supply voltage UB
Current consumption
Linearity error
Setting accuracy
Temperature coefficient
Test voltage, input/output/supply
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

N
L 1
8

M C R -S L -P T 1 0 0 -S P

11

12

DC
DC

Type

Order No.

MCR-SL-PT100-SP

2814948

11

14

Pcs. /
Pkt.

MCR temperature relay, for Pt 100 in 2-wire system

Error/status indicator

Screw
M3

+24 VDC 3

The MCR-SL-PT100-SP temperature


relay converts the measured values of the Pt
100 sensor (IEC 60751/ EN 60751) into
binary switching signals.
The sensor is supplied with a small
current from the module. The resulting
voltage drop is amplified in the module and
linearized with a characteristic curve.
The switching threshold is set internally
by a rough preselection via DIP switches and
by a fine adjustment via a potentiometer on
the front. A high-quality PDT relay with gold
layer is located on the output side.
The device has adjustable open circuit
behavior. To increase the process reliability,
the relay module has electrical isolation to
the sensor signal.

OUT

SETPOINT

Pt 100 (IEC 60751/EN 60751) : 2-wire


-100C ... 700C
Approx. 1 mA
Relay output
1 PDT
AgSnO, hard gold-plated
50 mA (for gold layer, 30 V AC/ 36 V DC)
2 A (in case of a destroyed gold layer, 250 V AC)
Approx. 6 ms
Approx. 200 ms
Adjustable using DIP switches (0.5 K, 2 K, 3 K, 5 K)
LED red (short circuit/wire break) /
LED yellow (relay active)
20 V DC ... 30 V DC
< 30 mA
< 0.1%
< 1%, Typ. < 0.5%
< 0.01%/K, Typ. 0.005%/K
1.5 kV (50 Hz, 1 min.)
-20C ... 65C
Any
Polyamide PA non-reinforced
CE compliant
cULus

S P
E R R O R

1 0
0

2 0
K
3 0
5 0

4 0
S E T P O IN T
IN

2 4 V

G N D

+ 2 4 V

Mains
voltage

Temperature monitoring of a heated medium

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

373

INTERFACE Analog
MACX Analog / MCR Analog
Programmable loop-powered
temperature transducer
12,5

114,5

Temperature

99

FL

IN

POWER
OUT

MCR-FL-T-LP-I
Programmable loop-powered temperature transducer

uPz
Ex: U

Housing width 12.5

IN

For resistance thermometers,


thermocouples, resistance-type and
voltage sensors
Freely programmable via
MCR-PI-CONF-WIN

solid

Pluggable screw
connection

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

374

PHOENIX CONTACT

1
2

Screw
M3

5 OUT 1

DC
D

DC

Description

Type

Order No.

MCR temperature transducer, loop-powered


for resistance thermometers, thermocouples, resistance-type and
voltage sensors

MCR-FL-T-LP-I

2864561

Technical data
Input data
Resistance thermometers

Resistor
Voltage
Output data
Output signal
Maximum output signal
Load RB

4 ... 20 mA / 20 ... 4 mA
23 mA
(Max (Vsupply -12 V) / 0.023 A (current output))

Output signal with open circuit


Output signal with short circuit

3.6 mA or 21 mA (adjustable)
3.6 mA or 21 mA (adjustable, not for thermocouples)

Measuring range overrange/underrange

20.5 mA / 3.8 mA (linear increase/decrease)

Step response (10-90%)


Pickup delay
Test voltage input/output
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

Pcs. /
Pkt.

Pt, Ni (100, 500, 1000);


minimum measurement range 10 K : 2, 3, 4-wire
B, C, D, E, J, K, L, N, R, S, T, U;
minimum measurement range 50 K/500 K
Resistance-type sensor from 10 to 400 and from 10 to 2000 ;
minimum measurement range 10 /100
-10 mV ... 100 mV (min. measurement range 5 mV)

Thermocouple sensors

General data
Supply voltage UB
Current consumption
Transmission error

6 GND 1

3
+

The universal PC-programmable


temperature transducers convert
temperature signals from resistance
thermometers and thermocouples as well
as from sensors with linear mV
characteristic curves into analog 4...20 mA
signals.
On the output side, the temperature
transducers are operated in a 4...20 mA
current loop, which simultaneously provides
the power supply for the modules,
necessary for signal conversion.
Failure data in the event of sensor break
or sensor short-circuit, that can be set in
acc. with NE 43, and a high degree of
accuracy in the entire ambient temperature
range are the distinguishing features of the
electrically isolated measurement
transducers.
The devices are supplied in the standard
configuration: Pt 100 sensor, 0...100C
measuring range, 3-wire connection.
Using the MCR-PAC-T programming
adapter and the MCR/PI-CONF-WIN
configuration software, it is possible to
implement client-specific measurement
range settings, linearizations and
characteristic curve adaptations, refer to
page 389.

OUT

Resistance thermometers
Thermocouple sensors
Resistance-type sensors
Voltage sensor

12 V DC ... 35 V DC
< 3.5 mA
0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000)
Type 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R)
0.1 (10...400 ), 1.5 (10...2000 )
20 V (-10...100 mV)
<2s
4s
2 kV (50 Hz, 1 min.)
IP20
-40C ... 85C
Any
Polyamide PA non-reinforced
CE compliant
Class I, Div. 2, Groups A, B, C, D

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Programmable loop-powered
temperature transducer
99

Temperature

114,5

12,5

IN

I
PT100

POWER
OUT

MCR-SL-PT100-LP-I
Programmable loop-powered temperature transducer

SL

uPz
Ex: U

Housing width 12.5

IN

For Pt 100 resistance thermometers


Freely programmable via
MCR-PI-CONF-WIN

OUT

1
solid

The universal PC-programmable


temperature transducers convert
temperature signals from resistance
thermometers into analog 4...20 mA signals.
On the output side, the temperature
transducers are operated in a 4...20 mA
current loop, which simultaneously provides
the power supply for the modules,
necessary for signal conversion.
Failure data in the event of sensor break
or sensor short-circuit, that can be set in
acc. with NE 43, and a high degree of
accuracy in the entire ambient temperature
range are the distinguishing features of the
electrically isolated measurement
transducers.
The devices are supplied in the standard
configuration: Pt 100 sensor, 0...100C
measuring range, 3-wire connection.
Using the MCR-PAC-T programming
adapter and the MCR/PI-CONF-WIN
configuration software, it is possible to
implement client-specific measurement
range settings, linearizations and
characteristic curve adaptations, refer to
page 389.

Pluggable screw
connection

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-24

Screw
M3

5 OUT 1

DC
D

DC

6 GND 1

3
4

Description

Type

Order No.

MCR temperature transducer, loop-powered


for Pt 100 resistance thermometer

MCR-SL-PT100-LP-I

2864558

Technical data
Input data
Resistance thermometers
Output data
Output signal
Maximum output signal
Load RB

4 ... 20 mA / 20 ... 4 mA
23 mA
(Max (Vsupply -12 V) / 0.023 A (current output))

Output signal with open circuit


Output signal with short circuit
Measuring range overrange/underrange

3.6 mA or 21 mA (adjustable)
3.6 mA or 21 mA (adjustable)
20.5 mA / 3.8 mA (linear increase/decrease)

General data
Supply voltage UB
Current consumption
Transmission error
Step response (10-90%)
Pickup delay
Test voltage input/output
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

Pcs. /
Pkt.

Pt 100 ; minimum measurement range 10 K : 2, 3, 4-wire

Resistance thermometers

12 V DC ... 35 V DC
< 3.5 mA
0.2 K
<2s
4s
2 kV (50 Hz, 1 min.)
IP20
-40C ... 85C
Any
Polyamide PA non-reinforced
CE compliant
Class I, Div. 2, Groups A, B, C, D

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

375

INTERFACE Analog
MACX Analog / MCR Analog
Programmable loop-powered
temperature head transmitters
44
33

IN

POWER
OUT

MCR-FL-HT-T-I
Programmable loop-powered temperature transducer

21

Temperature

FL

uPz
Ex: U

Housing width

IN

For resistance thermometers,


thermocouples, resistance-type and
voltage sensors
For mounting in the connecting head,
form B
Freely programmable via
MCR-PI-CONF-WIN

PHOENIX CONTACT

AWG
24-15

Screw
M3

1 OUT 1

DC
D

DC

2 GND 1

5
6

The universal PC-programmable


temperature transducers convert
temperature signals from resistance
thermometers and thermocouples as well
as from sensors with linear mV
characteristic curves into analog 4...20 mA
signals.
On the output side, the temperature
transducers are operated in a 4...20 mA
current loop, which simultaneously provides
the power supply for the modules,
necessary for signal conversion.
Failure data in the event of sensor break
or sensor short-circuit, that can be set in
acc. with NE 43, and a high degree of
accuracy in the entire ambient temperature
range are the distinguishing features of the
measurement transducers.
The devices are supplied in the standard
configuration: Pt 100 sensor, 0...100C
measuring range, 3-wire connection.
Using the MCR-PAC-T programming
adapter and the MCR/PI-CONF-WIN
configuration software, it is possible to
implement client-specific measurement
range settings, linearizations and
characteristic curve adaptations, refer to
page 389.

376

solid

Screw connection

stranded
[mm2]
0.2-1.75 0.2-1.75

OUT

Description

Type

Order No.

MCR-FL-HT-T-I

2864529

Pcs. /
Pkt.

MCR temperature head transmitters, loop-powered


for resistance thermometers, thermocouples, resistance-type and
voltage sensors
Technical data
Input data
Resistance thermometers

Pt, Ni (100, 500, 1000);


minimum measurement range 10 K : 2, 3, 4-wire
B, C, D, E, J, K, L, N, R, S, T, U;
minimum measurement range 50 K/500 K
Resistance-type sensor from 10 to 400 and from 10 to 2000 ;
minimum measurement range 10 /100
-10 mV ... 75 mV (min. measurement range 5 mV)

Thermocouple sensors
Resistor
Voltage
Output data
Output signal
Maximum output signal
Load RB

4 ... 20 mA / 20 ... 4 mA
25 mA
(Max (Vsupply - 8 V) / 0.025 A (current output))

Output signal with open circuit


Output signal with short circuit

3.6 mA or 21 mA (adjustable)
3.6 mA or 21 mA (adjustable, not for thermocouples)

Measuring range overrange/underrange

20.5 mA / 3.8 mA (linear increase/decrease)

General data
Supply voltage UB
Current consumption
Transmission error

Step response (10-90%)


Pickup delay
Test voltage input/output
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

Resistance thermometers
Thermocouple sensors
Resistance-type sensors
Voltage sensor

8 V DC ... 35 V DC
< 3.5 mA
0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000)
Type 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R)
0.1 (10...400 ), 1.5 (10...2000 )
20 V (-10...100 mV)
<2s
6s
2 kV (50 Hz, 1 min.)
IP00, IP66 (integrated in the connecting head)
-40C ... 85C
Any
Polycarbonate PC
CE compliant
Class I, Div. 2, Groups A, B, C, D

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Programmable loop-powered
temperature head transmitters
44
33

I
PT100

Temperature

IN

POWER
OUT

MCR-SL-HT-PT 100-I
Programmable loop-powered temperature transducer

21

SL

uPz
Ex: U

Housing width

IN

For Pt 100 resistance thermometers


For mounting in the connecting head,
form B
Freely programmable via
MCR-PI-CONF-WIN

solid

Screw connection

stranded
[mm2]
0.2-1.75 0.2-1.75

OUT

AWG
24-15

Screw
M3

1 OUT 1

DC
D

DC

2 GND 1

The universal PC-programmable


temperature transducers convert
temperature signals from resistance
thermometers into analog 4...20 mA signals.
On the output side, the temperature
transducers are operated in a 4...20 mA
current loop, which simultaneously provides
the power supply for the modules,
necessary for signal conversion.
Failure data in the event of sensor break
or sensor short-circuit, that can be set in
acc. with NE 43, and a high degree of
accuracy in the entire ambient temperature
range are the distinguishing features of the
measurement transducers.
The devices are supplied in the standard
configuration: Pt 100 sensor, 0...100C
measuring range, 3-wire connection.
Using the MCR-PAC-T programming
adapter and the MCR/PI-CONF-WIN
configuration software, it is possible to
implement client-specific measurement
range settings, linearizations and
characteristic curve adaptations, refer to
page 389.

Description

Type

Order No.

MCR-SL-HT-PT 100-I

2864516

Pcs. /
Pkt.

MCR temperature measuring transducer, loop-powered


for Pt 100 resistance thermometer
Technical data
Input data
Resistance thermometers
Output data
Output signal
Maximum output signal
Load RB

4 ... 20 mA / 20 ... 4 mA
23 mA
(Max (Vsupply - 10 V) / 0.023 A (current output))

Output signal with open circuit


Output signal with short circuit
Measuring range overrange/underrange

3.6 mA or 21 mA (adjustable)
3.6 mA or 21 mA (adjustable)
20.5 mA / 3.8 mA (linear increase/decrease)

General data
Supply voltage UB
Current consumption
Transmission error
Step response (10-90%)
Pickup delay
Degree of protection
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

Pt 100 ; minimum measurement range 10 K : 2, 3, 4-wire

Resistance thermometers

10 V DC ... 35 V DC
< 3.5 mA
0.2 K
<2s
4s
IP00, IP54 (integrated in the connecting head)
-40C ... 85C
Any
Polycarbonate PC
CE compliant
Class I, Div. 2, Groups A, B, C, D

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

377

INTERFACE Analog
MACX Analog / MCR Analog
Programmable frequency transducers

FL

U,I
IN

f,U,I

45

110

Conversion

75

OUT

MCR-F-UI-DC
POWER

Programmable frequency transducer for frequencies up to 120 kHz

uPFz
Ex: U

Housing width 45

Frequencies up to 120 kHz


Analog and switching output
3-way isolation
Programmable using membrane keypad or
software
Display of input or output signal

Pluggable screw
connection

stranded
[mm2]
0.2-2.5
0.2-2.5

NPN
PNP

solid

AWG
24-14

Screw
M3

Dry
Contact

1
2

+8,2 V

3
4

f in

5
6

NPN
PNP
+15 V

DC
DC

Namur
IN

DC

GND 1

mC

A
0-10 V

U in

I in

0-20 mA

The MCR-F-UI-DC programmable


frequency transducer is a module for
displaying and converting frequencies up to
120 kHz into analog standard signals.
The transmission behavior of the
frequency measuring transducer can be set
on the front using the membrane keypad or
the MCR/PI-CONF-WIN configuration
software, refer to page 389.
Either the input value for the measured
frequency or the standard output signals
can be read off on the front LC display.
All common frequency generator signals
with 2, 3 or 4-wire technology and the
signals of incremental rotary transducers
can be recorded on the input side, e.g.:
NAMUR sensors
Frequency generators
Floating contacts
NPN/PNP transistor outputs
In addition, there is also a PNP transistor
switching output with a maximum carrying
capacity of 100 mA, for alarm processing,
for example (not short-circuit proof).

Description

PHOENIX CONTACT

11

SW

12

GND

13

NC

14

I OUT

15
16

U OUT
GND 2

Type

Order No.

MCR-F-UI-DC

2814605

Pcs. /
Pkt.

MCR frequency measuring transducer, for conversion of


frequencies into analog signals 0(4)...20 mA, 0...(5)10 V and their
inverse signals
Technical data
Input data
Frequency range
Input sources

Transducer supply
Signal level

Maximum input signal


Signal form
Pulse length
Resolution
Signal conversion time
Input data
Input signal (can be set freely)
Maximum input signal
Input resistance
Resolution
Step response (10-90%)
Output data
Output signal (normal and inverse)
Maximum output signal
Load RB
Ripple
Switching output

General data
Supply voltage UB
Current consumption
Transmission error, max.
Temperature coefficient
ZERO / SPAN adjustment
Test voltage, input/output/supply
Ambient temperature (operation)
Status indication
Operating elements
Housing material
Conformance / approvals
Conformity
UL, USA / Canada
GL

378

+24 V
GND

D
A

9
10

Frequency input
0.1 Hz ... 120 kHz
NPN/PNP transistor outputs
NAMUR initiators
Floating relay contact (dry contact)
Frequency generator
Approx. 15 V DC / Max. 25 mA (constant)
2 VPP (In case of rectangle 0.1 Hz ... 120 kHz)
2 VPP (In case of sine 8 Hz ... 120 kHz)
13 VPP (In case of sine 1 Hz ... 120 kHz)
30 V (incl. DC voltage)
Any
1 s
> 12 bit
32 ms
Isolating amplifier function
0 ... 10 V
0 ... 20 mA
12 V
24 mA
95 k
200
14 bit (full-scale)
14 bit (full-scale)
< 25 ms
< 25 ms
U output
I output
0 ... 5 V / 0 ... 10 V
0 ... 20 mA / 4 ... 20 mA
12.5 V
25 mA
500
500
< 20 mVPP
< 20 mVPP
Transistor output, pnp
Switches supply voltage to terminal block SW, can carry a load of
100 mA, not protected against short circuit
20 V DC ... 30 V DC
< 60 mA (without load, without switching output)
0.15% (of measured value), Typ. 0.1%
0.015%/K, Typ. 0.01%/K
25% / 25%
1.5 kV (50 Hz, 1 min.)
-20C ... 65C (for specified data)
LC display
Membrane keypad with 3 keys and LCD display
ASA-PC (V0)
CE compliant
Class I, Div. 2, Groups A, B, C, D or non-hazardous locations
Germanischer Lloyd

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Connection examples for common frequency transmitters

7 U IN

8 I IN

8 I IN

8 I IN

bu

bk
wh

npn

bk

4 GND1
NPN
5 PNP
6 +15 V
7 U IN

7 U IN
8 I IN

1 +8,2 V
2 NAMUR
IN
3 f IN

Incremental rotary transducer with push-pull:


Supply of the external signaling encoder
UB = 5-30 V DC

UB = 0 V DC

4 GND1
NPN
5 PNP
6 +15 V

4 GND1
NPN
5 PNP
6 +15 V

UB = 24 V DC

K1, K2, K0
K1, K2, K0

15 V/25 mA

1 +8,2 V
2 NAMUR
IN
3 f IN
4 GND1
NPN
5 PNP
6 +15 V

1 +8,2 V
2 NAMUR
IN
3 f IN
4 GND1
NPN
5 PNP
6 +15 V

UB = 0 V

8 I IN

Supply of the signaling encoder from the module


15 V/25 mA

The external supply can


be picked off by
terminal blocks 9
+24VDC and 0 GND
as well.
Any 3-way isolation
then no longer applies.

K1, K2, K0
K1, K2, K0

1 +8,2 V
2 NAMUR
IN
3 f IN
4 GND1
NPN
5 PNP
6 +15 V

7 U IN

7 U IN

7 U IN

8 I IN

8 I IN

8 I IN

Application examples:
The frequency transducer
MCR-F-UI-DC converts the pulse signal
into an analog standard signal that provides
information about the numbers of bottles in
filling systems recorded in a defined time
unit.
For speed measurements, it is possible to
enter the measuring range in revolutions
per minute (rpm) and to display the current
measured value on the device.
The frequency measuring transducer has
an automatic measuring range selection
function (autorange) to ensure the best
possible resolution. This permits response
times to be reduced to a minimum and the
measured value is optimally adapted to the
input value.

MCR-f-UI-DC

7 U IN

7 U IN

Supply of the signaling encoder from the module

MCR-f-UI-DC

bk

1 +8,2 V
2 NAMUR
IN
3 f IN

1 +8,2 V
2 NAMUR
IN
3 f IN

Incremental rotary transducer with HTL logic:


Supply of the external signaling encoder

8 I IN

With NPN transistor output

wh

bn

4 GND1
NPN
5 PNP
6 +15 V

8 I IN

8 I IN

npn

bu

7 U IN

7 U IN

bn

bk

1 +8,2 V
2 NAMUR
IN
3 f IN

8 I IN

4 GND1
NPN
5 PNP
6 +15 V

bu

1 +8,2 V
2 NAMUR
IN
3 f IN

bn

NPN transistor with pull-up resistance

MCR-f-UI-DC

1 +8,2 V
2 NAMUR
IN
3 f IN

With NPN transistor output

MCR-f-UI-DC

pnp

bn

4 GND1
NPN
5 PNP
6 +15 V

7 U IN

4-wire DC
With PNP transistor output

bu

bu

7 U IN

4 GND1
NPN
5 PNP
6 +15 V

bn

bk

MCR-f-UI-DC

4 GND1
NPN
5 PNP
6 +15 V

MCR-f-UI-DC

bu

bk

1 +8,2 V
2 NAMUR
IN
3 f IN

MCR-f-UI-DC

pnp

2-wire DC NAMUR sensor


bn

1 +8,2 V
2 NAMUR
IN
3 f IN

bu

Application example:
Flow measurement
1
2
3
4
NPN
PNP
Dry
Contact

5
6

+8,2 V

DC
DC

Namur
IN
F in

11 SW
C

NPN
PNP

0-10 V

7
8

12 GND

24 V

13 NC

+15 V

0-20 mA

9 +24 V
10 GND

DC

GND 1

NAMUR sensor

MCR-f-UI-DC

4 GND1
NPN
5 PNP
6 +15 V

Terminal block 1
also possible instead
of terminal block 6.

3-wire DC
PNP transistor with pull-down resistance

MCR-f-UI-DC

1 +8,2 V
2 NAMUR
IN
3 f IN

bn

MCR-f-UI-DC

bu

3-wire DC
With PNP transistor output

MCR-f-UI-DC

bn

MCR-f-UI-DC

2-wire DC (mechanical contact)

U in

D
A

I in

14 I OUT

Mains voltage
15 U OUT

D
A

16 GND 2

Control system

Application example:
Measurement of revolutions of a drive
1
2
3
4
NPN
PNP
Dry
Contact

5
6

+8,2 V

DC
DC

Namur
IN
F in

11 SW

GND 1

NPN
PNP

0-10 V

7
8

12 GND

24 V

13 NC

+15 V

0-20 mA

9 +24 V
10 GND

DC

U in

D
A

I in

14 I OUT

15 U OUT

D
D

Mains voltage

16 GND 2

NAMUR
Actuated: 1.2 mA
Not actuated: 2.1 mA

Control system

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

379

INTERFACE Analog
MACX Analog / MCR Analog
Programmable limit value switch

75

Control

110

FL

45

IN

,U,I,R

OUT

MCR-PSP-DC
POWER

Programmable threshold value switch


for standard and temperature signals

uP

Housing width 45

Four independently adjustable switching


thresholds
With or without electrical isolation of
input signals
Programmable using the
MCR-PI-CONF-WIN software
Continuous measured value display
The MCR-PSP threshold value switch is
used to monitor and control processes.
Four switching thresholds that can be
adjusted independently of one another
react to the signals of various thermocouple
sensors, resistance thermometers and
linear resistors that can be connected
directly. An input for analog signals is
provided to monitor process signals that
have already been converted.
Programming can be performed using
either the membrane keypad or the
configuration software MCR/PI-CONFWIN, refer to page 389.
The LED display constantly displays the
current measured value so that the process
value can also be monitored visually.
The two relays are designed as PDT
contacts with adjustable time delay, and the
limit values of each contact have a
modifiable hysteresis. The relays can be set
to pick up or drop out.
The devices with electrically isolated
inputs decouple the field level and supply,
thus avoiding the creation of distributed
measurement circuits.

380

PHOENIX CONTACT

(+) 24 VDC 1
POWER
2
(-) GND

0000

10

MM
shield
IN

solid

Pluggable screw
connection

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

3
4

12
11
14

OUT
22
21
24

Description

I ()
12
U ()
13 GND ()
14
U (-)
15
U (+)
16
I
11

6
7
8

Type

Order No.

MCR-PSP-DC
MCR-PSP

2811925
2811912

Pcs. /
Pkt.

MCR threshold value switch, with two relay contacts


With electrically isolated input
Technical data
Input data
Input sources

Measuring rate
Input resistance
Discontinuous control resolution
Switching output
Contact type
Contact material
Max. switching voltage
Max. switching current
Mechanical life
Response delay
Status indication
General data
Supply voltage UB
Current consumption
Transmission error, max.
Temperature coefficient
Test voltage input/power supply
Ambient temperature (operation)
Status indication
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

Current / voltage

1
1

Resistance thermometer 2, 3 or 4-wire system


(in acc. with DIN 43760/DIN IEC 751 or SAMA RC 21-4-1966),
e.g. PT sensors, Ni sensors etc.
Thermocouple sensors (in acc. with DIN IEC 584-1/DIN 43710):
B, E, J, K, L, N, R, S, T, U
Resistance: 0 k ... 8 k (only 2-wire connection)
Current: - 30 mA...+ 30 mA
Voltage: - 30 V...+ 30 V
2 Hz
50 / 200 k
0,1C / 0,01 V / 0,01 mA / 0,1
2 x PDT contact, / 2 switching points each, pick-up/drop-out (can be
switched)
AgNi 0,15 + HTV (hard gold-plated)
250 V AC
2 A AC
2 x 107 cycles
0 s ... 2 s (adjustable)
LED display
20 V DC ... 30 V DC
< 60 mA
0.1% (of end value)
0.01%/K
1 kV AC (50 Hz, 1 min.)
-20C ... 65C
5-position 7-segment display and LEDs
Any
ABS
CE compliant
cULus

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Limit value switches

75

45

108

Control

FL

IN

U,I

OUT

MCR-2SP-UI-DC
POWER

Limit value switch with two isolated, adjustable relay outputs

uPz

Housing width 45

OUT1

IN

Two relay outputs


Two adjustable limit values
With electrical isolation of supply voltage
The MCR-2SP-UI-DC threshold value
switch monitors standard analog signals in
the ranges 0...10 V and 0...20 mA.
Limit values 1 and 2 can be set
independently either using two decade
switches on the front side or by specifying
analog values.
If the set switching thresholds are
exceeded, two relays with PDT contacts are
activated. The two relays can be set to
either drop out or pick up (normally
closed/normally open function)
A time delay of up to four seconds can be
selected (set) separately for each limit value
with two potentiometers.
The differential inputs allow several limit
value switches to be connected in series in
order to realize any number of limit values.

(-) IN
(+) IN

1
2

(-)
1
(+)
SET POINT
(-)
2
(+)
POWER
(-) GND
(+) 24 VDC

3
4

5
6

11 12
12 11

solid

Pluggable screw
connection

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

Description

13 14
+

14 22

15 21
-

7
8

16 24

9 9

1 1

OUT2

Type

Order No.

MCR-2SP-UI-DC

2769873

Pcs. /
Pkt.

MCR threshold value switch, with two separately adjustable relay


contacts and electrically isolated supply

Technical data
Input data
Input signal
Maximum input signal
Input resistance
Limit value setting

U input
I input
0 ... 10 V
0 ... 20 mA
13 V
100 mA
200 k
50
2-figure momentary-contact coding switch (0 ... 99%)
External analog value definition
2-figure momentary-contact coding switch (0 ... 99%) and external
analog value definition
Approx. 100 mV
Approx. 200 A
Relay output
2 PDT contact, pick-up/drop-out (can be switched)
Silver cadmium oxide (AgCdO)
250 V AC
3A
3 x 107 cycles
8 ms ... 4 s (adjustable)
LED

Internal hysteresis
Switching output
Contact type
Contact material
Max. switching voltage
Max. switching current
Mechanical life
Response delay
Status indication
General data
Supply voltage UB
Current consumption
Temperature coefficient
Step response (10-90%)
Test voltage input/power supply
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

20 V DC ... 30 V DC
< 100 mA
0.01%/K
8 ms
1 kV AC (50 Hz, 1 min.)
-20C ... 65C
Any
ABS
CE compliant
cULus
Drive with speed
torquesensor

POWER

Monitoring and control of a


mixing process

11

0...20 mA

12

0s

MCR-2SP-UI-DC

SETPOINT 1

TIME 1

0s

2/3-way valve

4s

TIME 2

SETPOINT 2

4s

13
14
15
16

Control system
M
24 V

24 V

Mains voltage
Mixing weight
Mains voltage

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

381

INTERFACE Analog
MACX Analog / MCR Analog
Limit value switches

17,5

Control

114,5

99

IN

U,I

3x

OUT

MCR-SWS-...
SL

POWER

Limit value switch for standard signals

uPz

Housing width 17.5

OUT

IN

Relay/transistor output
Limit indicator
Adjustable hysteresis
Monitoring of three signal statuses

solid

Pluggable screw
connection

The MCR-SWS threshold value switch


is used to monitor simple automation
processes. On the input side, 0...10 V or
0...20 mA standard analog signals are
processed.
The single-ended current input can be
isolated using a jumper and therefore used
as the differential current input. With the
aid of the differential input, it is possible to
connect several limit value switches in
series in order to monitor a current value.
A limit value is set in the module from the
0...10 V or 0(4)...20 mA analog input signals
via a potentiometer. If the input signal
reaches the threshold value, a relay PDT
contact is actuated at the output.
After the limit value has been set, the
required hysteresis (setting point) can be
set by means of another potentiometer.
Both switching points affect a relay.
For monitoring, the three signal range
statuses (A, B, C) - below, in and above the
hysteresis - are available as transistor
outputs. LEDs indicate the three signal
ranges.

382

PHOENIX CONTACT

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

IN I/U 1
GND 1 2
GND 1 3
12
11
14

A B C

4
5
6

IN

7 OUT A
8 OUT B
9 OUT C
+ 24VDC
GND 2
12 GND 2

10

11

Description

Type

Order No.

MCR threshold value switch, with adjustable hysteresis and


relay/transistor output
Input: 0..0.10 V
Input: 0(4) - 20 mA

MCR-SWS-U
MCR-SWS-I

2766465
2766478

Technical data
Input data
Input signal
Maximum input signal
Input resistance
Limit value setting
Setting range of the limit value
Setting range for the hysteresis
Internal hysteresis
Switching output
Number of outputs
Output voltage
Continuous load current
Switching output
Contact type
Contact material
Max. switching voltage
Max. switching current
Mechanical life
Status indication
General data
Supply voltage UB
Current consumption
Temperature coefficient
Step response (10-90%)
Ambient temperature (operation)
Assembly
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

Pcs. /
Pkt.

1
1

U input
I input
0 ... 10 V
0 ... 20 mA / 4 ... 20 mA
11 V
22 mA
100 k
120
Setting potentiometer, scaled 270 potentiometer
0 V ... 10 V
0 A ... 20 mA
0.1 V ... 10 V (setting accuracy: 0.2 mA ... 20 mA (setting
30 mV)
accuracy: 60 A)
30 mV (around the lower/upper 60 A (around the lower/upper
switching point)
switching point)
Transistor output, pnp
3
20 V DC ... 30 V DC
100 mA
Relay output
1 PDT
AgNi 0,15 + HTV (hard gold-plated)
250 V AC (30 V DC)
2A
107 cycles
LED
20 V DC ... 30 V DC
60 mA
0.02%/K
< 25 ms
-20C ... 65C
Any
Polyamide PA non-reinforced
CE compliant
cULus

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Digital display
Standard signals

Pr1

Pr2

48

96

00000

U,I

OUT
POWER

MCR-FL-D-U-I-2SP-...

83

IN

max. 19

Control

FL

Programmable digital display for standard analog signals

uP

Housing width 96

For standard analog signals


Programmable
5 positions displayed
Electrical isolation
2 relay outputs with freely selectable limit
values
Totalisator
Display 96 x 48 mm
The MCR-FL-D-UI-2SP-... digital
displays in the Function Line visualize
standard analog signals of 0...10 V and
0(4)...20 mA. On the output side, the
devices provide two relay outputs with a
freely adjustable hysteresis. The totalisator
enables the addition of measured values and
the total value display.
Outstanding features of the digital display
are the simple programmability of the
totalisator, threshold values with hysteresis
and up to 24 base points on the
characteristic curve. It has a display value
memory (latch/hold function) as well as an
encoder supply for sensors. The scaling
function offers the possibility of displaying
standard analog signals in freely selectable
physical measuring ranges (e.g. input signal
4. . .20 mA in the display range
0...150 l/min.)
The displays are available with 24 V DC as
well as with 230 V AC supply voltage.

OUT X2
n.c. 11
10 VDC/30 mA 10
GND 3 9

solid

Pluggable screw
connection
Pluggable screw
connection

stranded
[mm2]
0.14-1 0.14-1.5

AWG
26-16

Screw
M2

0.2-2.5

24-12

M3

0.2-2.5

RESET/LATCH
GND 2
KEY
n.c.
n.c.
U
GND 1
IN
I

8
7
6
5
4
3
2
1

A
D

X1
8
7
6
5
4
3
2
1

GND 4
+10...30 VDC
12
14 O UT 1
11
22
24 O UT 2
21

0000

Description

Type

Order No.

MCR digital display, for measurement and display of standard


signals
Supply voltage 24 V DC
Supply voltage 230 V AC

MCR-FL-D-U-I-2SP- 24
MCR-FL-D-U-I-2SP-230

2864215
2864228

Technical data
Input data
Input signal
Maximum input signal
Input resistance
Resolution
Measuring rate
Input latch signal
Input reset impulse

U input
I input
0 ... 10 V / -10 ... 10 V
0 ... 20 mA / 4 ... 20 mA
30 V
50 mA
> 1 M
< 50
1 mV
2 A
Approximately 2 measurements/second
Display stop
> 5 ms to reset the totalizer / the relay outputs

Switching level
Output data
display
Number of the displayed positions
Precision
Switching output
Contact type
Contact material
Max. switching voltage
Max. switching current
Min. switching current
Switching capacity
Switching hysteresis
Relay status display
Supply voltage for measuring transducer/sensor
General data
Supply voltage UB
Power consumption
Data memory
Resolution A/D
System hum suppression
Test voltage, input/output/supply
Degree of protection
Ambient temperature (operation)
Control panel cutout
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

1 signal ("H")
0 signal ("L")

Pcs. /
Pkt.

1
1

4 V DC ... 30 V DC
0 V DC ... 2 V DC
7-segment LED; 14.2 mm; red
5
< 0.1% 1 digit (At 20C ambient temperature)
MCR-FL-D-U-I-2SP- 24
MCR-FL-D-U-I-2SP-230
2 PDT
2 PDT
AgCdO
AgCdO
300 V DC / 250 V AC
300 V DC / 250 V AC
3A
3A
30 mA DC
30 mA DC
50 W / 2000 VA
50 W / 2000 VA
Programmable
Programmable
LED reds
LED reds
10 V DC 2%, 30 mA
10 V DC 2%, 30 mA
24 V DC 15%, 50 mA
MCR-FL-D-U-I-2SP- 24
MCR-FL-D-U-I-2SP-230
10 ... 30 V DC
90 ... 260 V DC
Max. 2 W
Max. 6 VA
EEPROM 1 mil. memory cycles or 10 years
14 Bit
Digital filtering 50/60 Hz
(500 Vrms / 2.3 kVrms, 50/60 Hz, 1 min.)
IP65 from the front
-20C ... 65C
92 (+0.8)x45(+0.6) mm
Macrolon 2405
CE compliant
UL 508 Recognized

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

383

INTERFACE Analog
MACX Analog / MCR Analog
Digital display
Standard signals

SL

U,I

00000

OUT

POWER

MCR-SL-D-U-I

59

IN

max. 19,3

Control

24

48

Programmable digital display for standard analog signals

uP

Housing width 48

10 VDC/30 mA

For standard analog signals


Programmable
5 positions displayed
Electrical isolation
Min./Max. value saving
Display 48 x 24 mm

Screw connection

PHOENIX CONTACT

stranded
[mm2]
AWG
0.14-1.5 0.14-1.5 26-16

GND 1 3

solid

Screw
M3

Description

LATCH 4

IN

The MCR-SL-D-UI digital display in the


Standard Line with five displaying positions
is used to display standard analog signals of
0...10 V and 0(4)...20 m.
Measured values can be easily read on the
high-resolution 8 mm high LED display. The
self-explanatory programmability of the
digital display offers the user enormous
time-savings.
The 24 V DC-supplied display in a
48 mm x 24 mm DIN format contains a
min./max. value memory. The position of
the decimal point can be freely programmed
via the front keys. The scaling function
offers the possibility of displaying standard
analog signals in freely selectable physical
measuring ranges (e.g. input signal 4...20 mA
in the display range 0...150 l/min.). The
digital display also has a latch/hold function
for saving display values.

384

GND 1 2

I 5
GND 2 6
U 7

A
D

0000

Type

Order No.

MCR-SL-D-U-I

2864011

Pcs. /
Pkt.

MCR digital display, for measurement and display of standard


signals
Technical data
Input data
Input signal
Maximum input signal
Input resistance
Resolution
Measuring rate
Input latch signal
Switching level
Output data
display
Number of the displayed positions
Precision
General data
Supply voltage UB
Current consumption
Data memory
Resolution A/D
System hum suppression
Test voltage input/power supply
Degree of protection
Ambient temperature (operation)
Control panel cutout
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

U input
0 ... 10 V
30 V DC
> 1 M

1 signal ("H")
0 signal ("L")

I input
0 ... 20 mA / 4 ... 20 mA
50 mA
(approx. 100 with 5 mA /
approx. 70 with 20 mA)
1 mV
2 A
Approximately 2 measurements/second
Display stop
4 V DC ... 30 V DC
0 V DC ... 2 V DC
7-segment LED; 8 mm; red
5
< 0.1% 1 digit (At 20C ambient temperature)
10 V DC ... 30 V DC
50 mA
EEPROM 1 mil. memory cycles or 10 years
14 Bit
Digital filtering 50/60 Hz
500 Vrms (50/60 Hz, 1 min.)
IP65 from the front
-10C ... 50C
22(+0.6)x45(+0.8) mm
Macrolon 2405
CE compliant
UL 508 Recognized

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Digital display
Frequencies, pulses, times

24

48

OUT

t
SL

POWER

MCR-SL-D-FIT

59

IN

max.19,3

Control

000000

Programmable digital display for frequencies, pulses and times

Housing width 48

+10...30V DC
0V / GND fin

For frequencies, pulses and times


Programmable
Data saving with Power Off
6 positions displayed
Display 48 x 24 mm

1
2

IN

solid

Pluggable screw
connection

stranded
[mm2]
0.14-1 0.14-1.5

AWG
26-16

Screw
M3
OUT

The Standard Line digital display MCR


SL-D-fit with six display positions is used
to display frequencies, pulses and times. The
required function can be configured quickly
and easily via the two front buttons.
Measured values can be easily read on the
high-resolution 8 mm high LED display. The
self-explanatory programmability of the
digital display offers the user enormous
time-savings.
The 24 V DC-supplied display in a
48 mm x 24 mm DIN format saves the data
if the supply voltage fails. The position of
the decimal point is freely selectable. The
digital display also has an optocoupler NPN
transistor output that can be used, among
other things, for counting applications and is
activated in the "zero" position.

Description

INP A / fin
INP B

SET / RESET

EMITTER

COLLECTOR

f
CNT
t

000000

Type

Order No.

MCR-SL-D-FIT

2864024

Pcs. /
Pkt.

MCR digital display, for measurement and display of frequencies,


pulses and times
Technical data
Input data
Signal input

Max. 60 kHz (CntDir)


Max. 25 kHz (UpDown / Up.Up/Quad 1/ Quad 2)
Max. 15 kHz ((Quad 4))
Setting function at setting value or zero
Min. 5 s
NPN/PNP transistor outputs, floating relay contacts

Reset input
Pulse time
Input sources
Polarity
Standard switching level
Switching level (5 V)
Input resistance
Impulse form
Output data
display
Number of the displayed positions
Accuracy of tacho / frequency counter
Timer accuracy
Switching output
Max. switching voltage
Max. switching current
Pulse counter function
Accuracy of tacho / frequency counter function
Timer function
General data
Supply voltage UB
Current consumption
Data memory
Degree of protection
Ambient temperature (operation)
Control panel cutout
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

1 signal ("H")
0 signal ("L")
1 signal ("H")
0 signal ("L")

Can be programmed jointly for all inputs


0.6 X U B ... 30 V DC
0 V DC ... 0.2 X UB
4 V DC ... 30 V DC
0 V DC ... 2 V DC
10 k
Any (Schmitt trigger input), rectangular pulse 1:1 at maximum
frequency
7-segment LED; 8 mm; red
6
< 0.1%
< 0.005%
30 V DC
10 mA
Active, at counter reading 0
active, at f = 0
1 Hz frequency, with active time measurement
10 V DC ... 30 V DC
Max. 40 mA
EEPROM 1 mil. memory cycles or 10 years
IP65 from the front
-20C ... 65C
22(+0.6)x45(+0.8) mm
Macrolon 2405
CE compliant
UL 508 Recognized

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

385

INTERFACE Analog
MACX Analog / MCR Analog
Digital display
Setpoint adjuster

SL

0000

Uref
Iref

OUT

POWER

MCR-SL-D-SPA-UI

59

IN

max.19,3

Control

24

48

Setpoint adjuster with manual and automatic ramp function

Housing width 48

Manual setpoint definition with step


width setting
Manual setpoint definition via direct input
Automatic setpoint definition with hold
function and 20 support points
Free presetting of signals in the range of
0...12 V or 0...24 mA
Data backup in case of a power failure
Display value parameterization
Electrical isolation between output and
supply
In test and control systems, setpoints are
often required for manual operation of
systems without sensor signals.
The MCR-SL-D-SPAUI setpoint
adjuster provides several solutions here.
Three setpoint definition modes selectable
via programming enable flexible adaptation
to your application. Setpoints can be
signaled manually as well as automatically via
20 support points. The flexibly adjustable
signal range of 0...12 V or
0...24 mA also provides a suitable setpoint
definition for every application in one
device.
Each display value can be assigned to the
particular output signal.

386

PHOENIX CONTACT

GND 1

HOLD

GND 2

solid

Pluggable screw
connection

stranded
[mm2]
AWG
0.14-1.5 0.14-1.5 26-16

+10...30 V

Screw
M3

DC
DC

7
C
6

IN

Description

D
0000

Type

Order No.

MCR-SL-D-SPA-UI

2710314

0...12 V
U OUT
GND 3
I OUT
0...24 mA

Pcs. /
Pkt.

MCR digital setpoint adjuster, for presetting current and voltage


signals
Technical data
Input data
display
Number of the displayed positions
Switching level, Hold
Output data
Output signal
Length of step
Load RB
Ripple
General data
Supply voltage UB
Power consumption
Transmission error, max.
Temperature coefficient
Test voltage output/power supply
Degree of protection
Ambient temperature (operation)
Control panel cutout
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

1 signal ("H")
0 signal ("L")

7-segment, 8 mm, red


4
4 V DC ... 30 V DC
0 V DC ... 2 V DC
I output
0 ... 24 mA
10 A
500 (Up to 20 mA)
10 mVPP

U output
0 ... 12 V
10 mV
2 k
10 mVPP

10 V DC ... 30 V DC
1 W (With 24 mA/12 V)
< 0.2% ((full-scale) at rated voltage)
0.02%/K
500 V AC (50 Hz, 1 min.)
IP65 from the front
-20C ... 65C
45(+0.6)x22.2(+0.3) mm
Macrolon 2405
CE compliant
UL 508 Recognized

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
DIN rail adapter for digital displays in
a 24 x 48 mm housing
For digital displays in DIN format
24 x 48 mm
For mounting digital displays on 35 mm
DIN rails in acc. with EN 60715
No tools necessary for mounting
The DIN rail adapter MCR-SL-D-RA
makes it possible to fix DIN format
24 x 48 mm digital displays on conventional
DIN rails acc. to EN 60715.
All digital displays can be adapted quickly
and easily. The mounting material required
is enclosed with the digital display and tools
are not necessary.
Just push in the digital display and snap it
on the DIN rail - done! Time-consuming
marking, drilling and filing are eliminated.

MCR-SL-D-RA
Description

Type

Order No.

MCR-SL-D-RA

2810081

Pcs. /
Pkt.

MCR DIN rail adapter for digital displays in a 24 x 48 mm housing

Technical data
General data
Mounting position
Housing material
Dimensions W / H / D

Any
PA-F
70 / 83.5 / 101 mm

Setpoint value potentiometer

30

68

75

Control

Uref
IN

OUT

EMG 30-SP-...LIN

U
SL

Description

Type

Order No.

Pcs. /
Pkt.

EMG 30-SP- 4K7LIN


EMG 30-SP/10K LIN

2940252
2942124

10
10

Setpoint potentiometer to set setpoints individually


Resistance value 4.7 k
Resistance value 10 k

The EMG 30-SP setpoint modules make


it possible to specify setpoints directly using
standard potentiometers.

Technical data
Input data
Resistance value
Linearity
Load capacity
General data
Ambient temperature (operation)
Assembly
Housing material
Connection data solid / stranded / AWG
Conformance / approvals
Conformity

EMG 30-SP- 4K7LIN


4.7 k 20%
5% (of end value)
1W

EMG 30-SP/10K LIN


10 k 20%
5% (of end value)
0.5 W

0C ... 40C
Any
Polycarbonate fiber reinforced PC-F
0.2 ... 4 mm / 0.2 ... 2.5 mm / 24 - 14
CE compliant

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

387

INTERFACE Analog
MACX Analog / MCR Analog
Constant voltage source

Control

POWER
IN

12,5

114,5

99

OUT

MCR-PS- 24DC-10DC

Uref

Constant voltage source for 10 V DC with short-circuit proof output

SL

Width 12.5 mm

OUT

The MCR-PS-24 DC-10 DC constant


voltage source provides a high precision
reference voltage of 10 V.
These modules are often required in
industrial processes in combination with
potentiometers for selecting setpoints.

Connection data
Input
Output

stranded
[mm2]
AWG
0.2-2.5
0.2-2.5 24-14
0.2-2.5
0.2-2.5 24-14

+ 10VDC
GND

5
6

U
REF

solid

M3

7
8

+ 24VDC
GND

IN

Description

Type

Order No.

MCR constant voltage source


Output voltage + 10 V DC

MCR-PS- 24DC-10DC

2766685

Technical data
Input data
Input nominal voltage range
Current consumption
Output data
Nominal output voltage
Short-circuit current
Ripple
General data
Ambient temperature (operation)
Installation position
Type of housing
Temperature coefficient
Conformance / approvals
Conformity

388

PHOENIX CONTACT

18 V DC ... 30 V DC
Approx. 10 mA (with no load on the output)
+ 10 V DC 0,1%
Approx. 65 mA
50 mVPP
-20C ... 65C
Any
Polyamide PA non-reinforced, color: green
0.015%/K
CE compliant

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Pcs. /
Pkt.

INTERFACE Analog
MACX Analog / MCR Analog
Configuration software package

Temperature transducers MCR-T-...,


MCR-...-LP-... and MCR-...-HT-...
Current transducer MCR-S-...
Frequency converter MCR-f-UI-DC
Limit value switch MCR-PSP-...
The MCR/PI-CONF-WIN
configuration software package is used
to configure and visualize all parameters for
the programmable MCR measuring
transducers.
Thanks to the convenient menu
interfaces, programmers do not have to
spend a long time studying the manual
before they start work.
The computer and the measuring
transducer communicate with one another
via a software adapter cable and a serial
interface.
The software runs under the following
operating systems: Windows 95, 98,
ME, NT, 2000 and XP.

MCR/PI-CONF-WIN
Description

Pcs. /
Pkt.

Type

Order No.

MCR/PI-CONF-WIN

2814799

MCR-ET 38X35 WH

2814317

MCR configuration software, for programming the MCR-T-...,


MCR-...-LP-..., MCR-...-HT-..., MCR-S-..., MCR-f-..., MCR-PSP-...,
modules, CD-ROM

Labels, for labeling MCR-T and MCR-S modules, four sheets DIN
A4 marking labels (112 pieces.)

USB adapter cable


Software adapter cable
For connecting the programmable
MCR-/PI modules to the USB interface of a
computer, the USB adapter cable
CM-KBL-RS232/USB can be used
together with the relevant adapter cables.
Programming with the MCR/PI-CONFWIN software is possible under the
operating systems Windows 98,
Windows 2000 and Windows XP.
The following modules are supported:
MCR-T-UI(-E)...
MCR-S-1-5-UI(-SW)-DCI...
MCR-f-UI-DC
MCR-PSP(-DC)
MCR-FL-T-LP-I
MCR-SL-PT100-LP-I
MCR-FL-HT-T-I
MCR-SL-HT-PT100-I

CM-KBL...
Description

Pcs. /
Pkt.

Type

Order No.

CM-KBL-RS232/USB

2881078

Software adapter cable (Stereo jack connector/SUB-D 25-pos.),


1.2 m length, for programming MCR-T..., MCR-S... and MCR-f...
modules

MCR-TTL-RS232-E

2814388

Software adapter cable (6-pos./SUB-D 25-pos.), 1.5 m length, for


programming MCR-PSP modules

MCR-TTL-RS232

2814391

Software adapter cable (Stereo jack connector/SUB-D 9-pos.),


1.6 m length, in X II (1) GD [EEx ia] IIC for programming PI-EXRTD... and PI-EX-THC... modules

PI-EX-TTL/RS232

2835312

Software adapter cable, 2.4 m length, for programming


MCR...LP... and MCR...HT... modules

MCR-PAC-T

2864590

Adapter cable, flexible, 9-pos. SUB-D socket on 25-pos. SUB-D


pin

PSM-KAD 9 SUB 25/BS

2761295

USB adapter cable,


D-9-SUB to USB, with adapter D-9-SUB to D-25-SUB

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

389

INTERFACE Analog
MACX Analog / MCR Analog
Active current transducer up to 11 A,
programmable and configurable
22,5

114,5

99

Power

FL

IN

U,I

OUT

MCR-S-1-5-UI(-SW)-DCI
POWER

Active current transducers,


programmable and configurable

uP
Ex: U

Housing width 22.5

IN
solid

Screw connection

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

12 1
11 2
14 3

The MCR-S-1-5-UI(-SW)-DCI current


transducers record direct, alternating and
distorted currents.
The MCR-S-1-5-UI(-SW)-DCI module
provides not only the standardized 1 A and
5 A input signals, but also the option of
setting current ranges of 0...0.2 A to
0...11 A progressively.
In addition to an analog output, these
current transducers also have an optional
transistor and relay output for alarm
triggering for example.
You also have the option of ordering a
pre-configured device, of carrying out the
configuration yourself using the DIP switch,
or of programming using the MCR/PICONF-WIN configuration software, refer
to page 389.
The desired configuration must be
specified when ordering pre-configured
modules (refer to the order key). If
specifications are incorrect or missing, the
devices will be supplied with the standard
configuration.

NC 4

OUT

Description

Order configuration
Standard configuration
Order configuration, without switching output
Standard configuration, without switching output
Technical data
Input data
Input current
Operate threshold
Frequency range
Curve type
Overload capacity
Surge strength
Connection method
Output data
Output signal (normal and inverse)

I
DAC

U
Po
wer

9 O UT I
10 O UT U
11 GND 2
12 GND 2
13 24VDC
14 GND 1
15 SW
16 GND 1

Type

Order No.

MCR-S-1-5-UI-SW-DCI
MCR-S-1-5-UI-SW-DCI-NC
MCR-S-1-5-UI-DCI
MCR-S-1-5-UI-DCI-NC

2814650
2814731
2814634
2814715

Load RB
Switching output
Relay output

Transistor output pnp

0 A ... 11 A (AC/DC)
(2% of measuring range nominal value 1/5/10 A)
15 Hz ... 400 Hz
AC, DC or distorted currents
2 x IN (continuous)
20 x IN (1 s)
Screw connection
U output
I output
0 ... 5 V / 1 ... 5 V / 0 ... 10 V
0 ... 20 mA / 4 ... 20 mA
2 ... 10 V / -5 ... 5 V / -10 ... 10 V
> 10 k
< 500
Contact material
Max. switching current
Output voltage
Continuous load current

Setting range of the threshold value


Response delay
Status indication
General data
Supply voltage UB
Current consumption
Transmission error, max.
Temperature coefficient
Step response (10-90%)
Safe isolation
Rated insulation voltage

PHOENIX CONTACT

OUT

DAC

Pcs. /
Pkt.

MCR current transducer for measuring AC, DC, and distorted


currents with relay and transistor switching output

Surge voltage category / pollution degree


Test voltage input/output
Test voltage input/power supply
Test voltage output/power supply
Degree of protection
Ambient temperature range
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

390

ADC

SPAN

Progressive adjustment of measuring


range
True r.m.s. value measurement
3-way isolation
With optional relay and transistor output

5
6
7

SET
TIME POINT ZERO

10A
5A
1A

1 PDT / AgSnO, hard gold-plated


50 mA (for gold layer, 30 V AC/ 36 V DC)
2 A (in case of a destroyed gold layer, 250 V AC)
19 V ... 29 V (supply voltage - 1 V)
80 mA (not short-circuit proof)
1% ... 110%
0.1 s ... 20 s
LED yellow
20 V DC ... 30 V DC
< 50 mA (without load)
< 0.5% (of range nominal value under nominal conditions)
Typ. < 0.025%/K
330 ms (with AC)
as per EN 50178, EN 61010
300 V AC (to earth)
III / 2
4 kV (50 Hz, 1 min.)
4 kV (50 Hz, 1 min.)
500 V (50 Hz, 1 min.)
IP20
-20C ... 60C
Polyamide PA non-reinforced
CE compliant
Class I, Zone 2, AEx nC IIC T6, Ex nC IIC T6

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

1
1
1
1

INTERFACE Analog
MACX Analog / MCR Analog
Active current transducer up to 55 A,
programmable and configurable
22,5

114,5

99

Power

FL

IN

U,I

OUT

MCR-S-10-50-UI(-SW)-DCI
POWER

Active current transducers,


programmable and configurable

uP
Ex: U

Housing width 22.5


ADC

IN
SPAN

solid

Screw connection

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

12 1
11 2
14 3

The MCR-S-10-50-UI(-SW)-DCI
current transducers record direct,
alternating and distorted currents.
Higher motor currents can also be
measured in case of the measuring ranges,
0...9.5 A to 0...55 A.
In addition to an analog output, these
current transducers also have an optional
transistor and relay output for alarm
triggering for example.
You also have the option to ordering a
pre-configured device, of carrying out the
configuration yourself using the DIP switch
or of programming using the MCR/PICONF-WIN configuration software, refer
to page 389.
The desired configuration must be
specified when ordering pre-configured
modules (refer to the order key). If
specifications are incorrect or missing, the
devices will be supplied with the standard
configuration.

NC 4

OUT

Description

SET
TIME POINT ZERO

Progressive adjustment of measuring


range
True r.m.s. value measurement
3-way isolation
With optional relay and transistor output

OUT

DAC

9 O UT I
10 O UT U

DAC

11 GND 2
12 GND 2

U
Po
wer

13 24VDC
14 GND 1

15 SW
16 GND 1

Type

Order No.

MCR-S-10-50-UI-SW-DCI
MCR-S10-50-UI-SW-DCI-NC
MCR-S-10-50-UI-DCI
MCR-S10-50-UI-DCI-NC

2814663
2814744
2814647
2814728

Pcs. /
Pkt.

MCR current transducer for measuring AC, DC, and distorted


currents with relay and transistor switching output
Order configuration
Standard configuration
Order configuration, without switching output
Standard configuration, without switching output
Technical data
Input data
Input current
Operate threshold
Frequency range
Curve type
Overload capacity
Surge strength
Connection method
Output data
Output signal (normal and inverse)
Load RB
Switching output
Relay output

Transistor output pnp

0 A ... 55 A (AC/DC)
(0.8% of measuring range nominal value 50 A)
15 Hz ... 400 Hz
AC, DC or distorted currents
Depending on through connected conductor
Depending on through connected conductor
Through connection, diameter 10.5 mm
U output
I output
0 ... 5 V / 1 ... 5 V / 0 ... 10 V
0 ... 20 mA / 4 ... 20 mA
2 ... 10 V / -5 ... 5 V / -10 ... 10 V
> 10 k
< 500
Contact material
Max. switching current
Output voltage
Continuous load current

Setting range of the threshold value


Response delay
Status indication
General data
Supply voltage UB
Current consumption
Transmission error, max.
Temperature coefficient
Step response (10-90%)
Safe isolation
Rated insulation voltage
Surge voltage category / pollution degree
Test voltage input/output
Test voltage input/power supply
Test voltage output/power supply
Degree of protection
Ambient temperature range
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

1
1
1
1

1 PDT / AgSnO, hard gold-plated


50 mA (for gold layer, 30 V AC/ 36 V DC)
2 A (in case of a destroyed gold layer, 250 V AC)
19 V ... 29 V (supply voltage - 1 V)
80 mA (not short-circuit proof)
1% ... 110%
0.1 s ... 20 s
LED yellow
20 V DC ... 30 V DC
< 50 mA (without load)
< 0.5% (of range nominal value under nominal conditions)
Typ. < 0.025%/K
330 ms (with AC) 40 ms (with DC)
as per EN 50178, EN 61010
300 V AC (to earth)
III / 2
4 kV (50 Hz, 1 min.)
4 kV (50 Hz, 1 min.)
500 V (50 Hz, 1 min.)
IP20
-20C ... 60C
Polyamide PA non-reinforced
CE compliant
Class I, Zone 2, AEx nC IIC T6, Ex nC IIC T6

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

391

INTERFACE Analog
MACX Analog / MCR Analog
Order key for the current transducers (Standard configuration entered as example)

Order No.
2814634
2814650

Measuring range:
Start
End
/
0.00
/

5.00

OUT01

5.00

OUT01

2814634 =
MCR-S-1-5-UI-DCI
2814650 =
MCR-S-1-5-UI-SW-DCI

Order No.
2814647
2814663

0.00

Output

Measuring range
starting value is
between
0.007.50 A

Measuring range
final value
between
0.2...11 A

0.00 = 0.00 A

5.00 = 5.00 A

OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT07
OUT08
OUT09
OUT10
OUT11
OUT12
OUT13
OUT14
OUT17
OUT18

Measuring range:
Start
End
/
0.0
/

50.0

50.0

2814647 =
MCR-S-10-50-UI-DCI
2814663 =
MCR-S-10-50-UI-SW-DCI

0.0

Threshold value

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

0...20 mA
4...20 mA
0...10 V
2...10 V
0...5 V
1...5 V
20...0 mA
20...4 mA
10...0 V
10...2V
5...0 V
5...1 V
-5...+5 V
-10...+10 V
+10...-10 V
+5...-5 V

Output

Measuring range
start value is
between
0.0037.5 A

Measuring range
final value
between
9.5...55 A

0.0 = 0.0 A

50.0 = 50.0 A

50

Suppression time Operating behavior of relay and transistor

3.0

Switching threshold
between 1 ... 110%

between
0.1 ... 20 s

50 = 50% of set upper


measuring range
value (here: 2.5 A)

3.0 = 3 s

Threshold value

A = Operating
current
controlled

O = Overrange

R = Closed-circuit
current
controlled

U = Underrange

Suppression time Operating behavior and Transistor

OUT01
OUT01
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT07
OUT08
OUT09
OUT10
OUT11
OUT12
OUT13
OUT14
OUT17
OUT18

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

0...20 mA
4...20 mA
0...10 V
2...10 V
0...5 V
1...5 V
20...0 mA
20...4 mA
10...0 V
10...2V
5...0 V
5...1 V
-5...+5 V
-10...+10 V
+10...-10 V
+5...-5 V

50

3.0

Switching threshold
between 1 ... 110%

between
0.1 ... 20 s

50 = 50% of set upper


measuring range
value (here: 25 A)

3.0 = 3 s

A = Operating
current
controlled

O = Overrange

R = Closed-circuit
current
controlled

U = Underrange

Function diagrams: Switching behavior of relay and transistor output:


1) Operating current-controlled when threshold value is exceeded

2) Operating current-controlled when threshold value is underrun


I IN

IIN
SW condition

SW condition

t
( H)

Operating voltage UB

t
( H)

Operating voltage UB

( L)

( L)
t

(1)
Relay N/O contact and
transistor output

(0)

t1

Relay N/O contact and


transistor output

t1

(0)

t1

(0)
Relay N/C contact

(1)

(0)
t1

t1

Relay N/C contact

t1

3) Quiescent current-controlled when above threshold value

4) Quiescent current-controlled when below the threshold value


IIN

IIN
SW condition

SW condition

t
Operating voltage UB

( H)

t
Operating voltage UB

( H)
( L)

( L)
t

(1)
Relay N/O contact and
transistor output

(0)

(1)
t1

Relay N/O contact and


transistor output

t1

t
t1

t1

(1)

(0)

Relay N/C contact

t
t1

(1)

(0) = N/O contact and transistor open / N/C contact closed


(1) = N/O contact and transistor closed / N/C contact open

PHOENIX CONTACT

t1

(0)

(0)
Relay N/C contact

392

(1)

(1)

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Current transducers for sinusoidal
alternating currents 0...1 A /0...5 A

22,5 7

114,5

104

Power

IN

OUT

MACX MCR-SL-CAC-5-I(-UP)
SL

POWER

Current transducers for sinusoidal alternating currents

Housing width 22.5

Ex: X // Applied for: UL-EX LIS / CUL-EX LIS


OUT

L(+) 1.1

Wide-range version from


19.2...253 V AC/DC
24 V DC version with additional supply
options through a DIN rail connector
3-way isolation
Input/output can be configured using the
DIP switch
Operating state signaling through LED
The MACX MCR-SL-CAC-5-I(-UP)
current transducers convert sinusoidal
alternating currents of 1 A or 5 A into
standard analog signals 0...20 mA or
4...20 mA.
Two versions are available:
MACX MCR-SL-CAC-5-I-UP
as a wide-range version of
19.2...253 V AC/DC.
MACX MCR-SL-CAC-5-I as a
24 V DC version of 19.2...30 V DC. In this
version, easy and quick power supply
through the DIN rail connector is
possible.

AWG
24-14

24V
A

Mains voltage

Current measurement

3.2

GND

N(-)

1.4

3.3

GND

3.4

GND

4.1

1A

4.2

5A

4.3

NC

IN

Type

Order No.

Pcs. /
Pkt.

Supply voltage 19.2 V DC ... 30 V DC


Supply voltage 19.2 V AC/DC ... 253 V AC/DC
DIN rail connector, for bridging the supply voltage (19.2...30 V
DC), can be snapped on to 35 mm DIN rails as per EN 60715

MACX MCR-SL-CAC-5-I
MACX MCR-SL-CAC-5-I-UP
ME 22,5 TBUS 1,5/ 5-ST-3,81 GN

2810612
2810625
2707437

1
1
50

System power supply unit, primary-switched (not for zone 2)


More information is given in the INTERFACE Power Supply catalog
part.
DIN rail connector, for bridging the supply voltage, can be
snapped onto 35 mm DIN rails as per EN 60715, with UL approval,
two pieces are required per system power supply

MINI-SYS-PS-100-240AC/24DC/1.5

2866983

ME 17,5 TBUS 1,5/ 5-ST-3,81 GN

2709561

10

Description
MCR current transducers for sinusoidal alternating currents

Technical data
Input data
Input current (configurable)

0 A AC ... 1 A AC (configurable) /
0 A AC ... 5 A AC (configurable)
50 Hz
45 Hz ... 65 Hz
Sine
2 x IN (continuous)
20 x IN (1 s)
Screw terminal block

Rated insulation voltage

0
00

1.3

4.4

Temperature coefficient
Step response (10-90%)
Safe isolation

5A

OUT1

N(-)

Screw
M3

Nominal frequency
Frequency range
Curve type
Overload capacity
Surge strength
Connection method
Output data
Output signal (configurable)
Maximum output signal
Load RB
Ripple
General data
Supply voltage UB
Current consumption
Transmission error, max.
0...20mA

3.1

solid

Screw connection

stranded
[mm2]
0.2-2.5
0.2-2.5

L(+) 1.2

Surge voltage category input/output


Pollution degree
Test voltage input/output
Test voltage output/power supply
Degree of protection
Ambient temperature range
Housing material
Conformance / approvals
Conformity
ATEX
UL, USA / Canada

0 ... 20 mA / 4 ... 20 mA
25 mA
< 500 (at 20 mA)
< 10 mVPP (for 500 at 20 mA)
MACX MCR-SL-CAC-5-I
19.2 V DC ... 30 V DC
< 32 mA (for 24 V DC)
0.5% (of range nominal value
under nominal conditions)
< 0.02%/K
< 300 ms
acc. to EN 61010
300 V AC (to earth)
III
2
4 kV (50 Hz, 1 min.)
1.5 kV (50 Hz, 1 min.)
IP20
-20C ... 65C
Polyamide PA non-reinforced

MACX MCR-SL-CAC-5-I-UP
19.2 V AC/DC ... 253 V AC/DC
< 30 mA (for 24 V DC)
0.5% (of range nominal value
under nominal conditions)
< 0.02%/K
< 300 ms
acc. to EN 61010
300 V AC (to earth)
III
2
4 kV (50 Hz, 1 min.)
2 kV (50 Hz, 1 min.)
IP20
-20C ... 65C
Polyamide PA non-reinforced

CE compliant
X II 3 G Ex nA II T4 X
UL applied for

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

393

INTERFACE Analog
MACX Analog / MCR Analog
Current transducers for sinusoidal and
non-sinusoidal alternating currents up
to 400 A

55

70,5

85

Power

IN

OUT

MCR-SL-S-...00-U
POWER

SL

Current transducer for sinusoidal and non-sinusoidal alternating


currents with voltage output 0...(5) 10 V

Ex: U

Housing width 55

True /r.m.s. value measurement from


30...6000 Hz
Measuring range selection with slide
switch
Can be retrofitted with the open-up
Rogowski coil
Through connection 18.5 mm
Electrical isolation of input and output
side
The MCR-SL-S-...-U- current
transducers convert sinusoidal and nonsinusoidal alternating currents up to 400 A
into analog standard signals of 0...5 V or
0...10 V. The measuring ranges for input and
output can be selected via a switch.
The open up Rogowski coil enables the
user to retrofit the current transducer in an
existing system without interruption.
Insulated conductors on the primary side
with a diameter of up to 18.5 mm can be
covered.

OUT
solid

Pluggable screw
connection

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

383A

24V

Mains voltage
MCR-SL-S-...-U

Order No.

MCR current transducers for sinusoidal and non-sinusoidal


alternating currents
Input current range: 0...50/75/100 A
Input current range: 0..0.100/150/200 A
Input current range: 0..0.200/300/400 A

MCR-SL-S-100-U
MCR-SL-S-200-U
MCR-SL-S-400-U

2813457
2813460
2813473

Technical data
Input data
Input current
Operate threshold
Frequency range
Curve type
Overload capacity
Impact overload capacity
Connection method
Output data
Output signal
Maximum output signal
Load RB
General data
Supply voltage UB
Current consumption
Transmission error, max.
Cable position error
Temperature coefficient
Step response (10-90%)
Safe isolation

...-S-100-U
...-S-200-U
...-S-400-U
0 ... 100 A
0 ... 200 A
0 ... 400 A
1% (of end value)
30 Hz ... 6000 Hz
Sinusoidal and non-sinusoidal
No limitation (permanent)
No limitation (for 1s)
Clamp-on cable design, diameter 18.5 mm
0 ... 5 V / 0 ... 10 V
((0 V ... 10 V) 14 V, (0 V ... 5 V) 7 V)
10 k

Surge voltage category / pollution degree


Test voltage input/output
Degree of protection
Ambient temperature range
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

20 V DC ... 30 V DC
< 30 mA
< 1% (of end value)
< 0.63%
< 0.035%/K
< 340 ms
As per IEC 61010-1 and IEC 61326
300 V AC (to earth)
III / 2
5 kV (50 Hz, 1 min.)
IP20
-20C ... 60C
Polyamide PA non-reinforced
CE compliant
cULus

0...5V
0...10V

L2
L3

Current measurement

PHOENIX CONTACT

Type

L1

394

GND
OUT

Description

Rated insulation voltage

IN

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

+24V

Pcs. /
Pkt.

1
1
1

INTERFACE Analog
MACX Analog / MCR Analog
Passive current transducers for
sinusoidal and non-sinusoidal
alternating currents up to 400 A

POWER

Power

IN
I

55

70,5

85

OUT

MCR-SL-S-...00-I-LP

SL

Current transducer for sinusoidal and non-sinusoidal alternating


currents with current output 4...20 mA (Loop-powered)

Ex: U

Housing width 55

True /r.m.s. value measurement from


30...6000 Hz
Measuring range selection with slide
switch
Loop-powered
Can be retrofitted with the open-up
Rogowski coil
Through connection 18.5 mm
Electrical isolation of input and output
side

OUT
solid

Pluggable screw
connection

The MCR-SL-S-...-I-LP- current


transducers convert sinusoidal and nonsinusoidal alternating currents up to 400 A
into the analog standard signal of 4...20 mA.
The measuring range on the output is set
with a switch. On the output side, the
current transducers are operated in a
4...20 mA current loop, which
simultaneously provides the power supply
for the modules, necessary for signal
conversion.
The open up Rogowski coil enables the
user to retrofit the current transducer in an
existing system without interruption.
Insulated conductors on the primary side
with a diameter of up to 18.5 mm can be
covered.

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

active PLC card

24V

U
I

Description

Type

Order No.

MCR current transducers for sinusoidal and non-sinusoidal


alternating currents
Input current range: 0...50/75/100 A
Input current range: 0..0.100/150/200 A
Input current range: 0..0.200/300/400 A

MCR-SL-S-100-I-LP
MCR-SL-S-200-I-LP
MCR-SL-S-400-I-LP

2813486
2813499
2813509

Technical data
Input data
Input current
Operate threshold
Frequency range
Curve type
Overload capacity
Impact overload capacity
Connection method
Output data
Output signal
Maximum output signal
Load RB
General data
Supply voltage UB
Transmission error, max.
Cable position error
Temperature coefficient
Step response (10-90%)
Safe isolation
Surge voltage category / pollution degree
Test voltage input/output
Degree of protection
Ambient temperature range
Housing material
Conformance / approvals
Conformity
UL, USA / Canada

OUT
+24V

Pcs. /
Pkt.

1
1
1

...-S-100-I-LP
...-S-200-I-LP
...-S-400-I-LP
0 ... 100 A
0 ... 200 A
0 ... 400 A
1% (of end value)
30 Hz ... 6000 Hz
Sinusoidal and non-sinusoidal
No limitation (permanent)
No limitation (for 1s)
Clamp-on cable design, diameter 18.5 mm
4 ... 20 mA
< 25 mA
((UB - 12 V) x 350 / 12 A)

Rated insulation voltage

IN

20 V DC ... 30 V DC
< 1% (of end value)
< 0.63%
< 0.025%/K
< 340 ms
As per IEC 61010-1 and IEC 61326
300 V AC (to earth)
III / 2
5 kV (50 Hz, 1 min.)
IP20
-20C ... 60C
Polyamide PA non-reinforced
CE compliant
cULus

UB=24V
4...20mA

Mains voltage
MCR-SL-S-...-I-LP

L1

L2
L3

Current monitoring

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

395

INTERFACE Analog
MACX Analog / MCR Analog
Passive current transducer for sinusoidal
alternating currents up to 5 A
22,5

114,5

99

Power

IN

U,I

OUT

MCR-SLP-1-5-UI-0
SL

Passive current transducers


for sinusoidal alternating currents

uP

Housing width 22.5

IN

Passive current transducer without supply


voltage
Measuring ranges 1 A and 5 A AC,
reconnectable
The passive MCR-SLP-1-5-UI-0 current
transducer converts sinusoidal alternating
currents of 1 and 5 A into standard 0...20
mA or 0...10 V analog signals.
The modules draw power from the
measurement circuit, which is needed to
convert the signals, making a separate
supply for the measuring transducer
unnecessary. Input and output sides are
electrically isolated from one another.

1A
5A
NC
solid

Screw connection

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

Description

Technical data
Input data
Input current
Frequency range
Curve type
Overload capacity
Surge strength
Permissible output range
Connection method
Output data
Output signal
Maximum output signal
Load RB

9 OUT I
J
10
500

Type

Order No.

MCR-SLP-1-5-UI-0

2814359

OUT U

11

GND

12

GND

Pcs. /
Pkt.

1 A input
5 A input
0 A AC ... 1 A AC
0 A AC ... 5 A AC
45 Hz ... 60 Hz
45 Hz ... 60 Hz
Sine
Sine
2 x IN (5 min. at 60C ambient temperature)
50 A (1 s)
100 A (1 s)
1.2 x IN
1.2 x IN
Screw connection
Screw connection
U output
I output
0 ... 10 V
0 ... 20 mA
20 V
30 mA
> 100 k
< 750
< 250 (when current and
voltage outputs are used
simultaneously)
< 50 mVPP
< 50 mVPP

Rated insulation voltage


Surge voltage category / pollution degree
Test voltage input/output
Degree of protection
Ambient temperature range
Housing material
Conformance / approvals
Conformity

PHOENIX CONTACT

OUT
IOUT

MCR passive current transducers for sinusoidal alternating


currents

Ripple
General data
Transmission error, max.
Temperature coefficient
Step response (10-90%)
Safe isolation

396

1
2
3
4

< 0.5% (of end value)


< 0.015%/K
< 200 ms
as per EN 50178, EN 61010
300 V AC (to earth)
III / 2
4 kV (50 Hz, 1 min.)
IP20
-25C ... 60C
Polyamide PA non-reinforced
CE compliant

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog
MACX Analog / MCR Analog
Current protectors for sinusoidal
alternating currents up to 16 A
22,5

114,5

99

Power

IN

OUT

MCR-SL-S-16-SP-24
POWER

SL

Contactor for sinusoidal alternating currents 0...16 A AC

uPz

Housing width 22.5


SETPOINT

Switching point can be freely selected in


the measuring range of 0...16 A AC
Changeover relay output
Electrical isolation
Adjustable switch hysteresis
Settable operating current / quiescent
current behavior
The MCR-SL-S-16-SP-24 current
protector converts sinusoidal 50 Hz/60 Hz
alternating currents into binary switching
signals.
The current is measured inductively via
the wire leading through the module. The
switching threshold is set internally by a
rough preselection via DIP switches and by
a fine adjustment via a potentiometer on
the front.
A high-quality PDT relay with a gold layer
is located on the output side. This can be
operated in both operating current and
closed circuit current behavior.

L1

Lighting system

10

40
30

NC

Emergency lighting

L2

20
K

14

RELAY ACTIV

50

SETPOINT

11

DELAY TIME

12

MCR - SL - S - 16 - SP - 24

5
6
7
8

Delay

Screw connection

stranded
[mm2]
0.2-2.5
0.2-2.5

IN

solid

AWG
24-14

Screw
M3

24V DC 13
GND 14
NC 15
NC 16

Description

=
=

12
11
14
NC

OUT

Type

Order No.

MCR-SL-S- 16-SP- 24

2864464

Pcs. /
Pkt.

MCR current protector for sinusoidal alternating currents

Technical data
Input data
Input current
Frequency range
Curve type
Overload capacity
Connection method
Switching output
Contact type
Contact material
Max. switching current
Switching hysteresis
Response delay
Operating and closed circuit current behavior
Relay status display
General data
Supply voltage UB
Current consumption
Setting accuracy
Temperature coefficient
Step response (10-90%)
Safe isolation
Rated insulation voltage
Surge voltage category / pollution degree
Test voltage input/output
Test voltage input/power supply
Degree of protection
Ambient temperature range
Housing material
Conformance / approvals
Conformity

0 A AC ... 16 A AC
45 Hz ... 65 Hz
Sine
2 x IN (continuous)
Through connection, diameter 4.2 mm
Relay output
1 PDT
AgSnO, hard gold-plated
50 mA (for gold layer, 30 V AC/ 36 V DC)
2 A (in case of a destroyed gold layer, 250 V AC)
Adjustable using a DIP switch (0.5%, 5%, 10%, 15%)
Typ. 0.1 s ... 10 s (adjustable using a potentiometer)
Adjustable using a DIP switch
LED yellow (relay active)
20 V DC ... 30 V DC
< 30 mA
< 0.5%
< 0.02%/K
40 ms
as per EN 50178, EN 61010-1
300 V AC (to earth)
III / 2
4 kV (50 Hz, 1 min.)
4 kV (50 Hz, 1 min.)
IP20
-20C ... 65C
Polyamide PA non-reinforced
CE compliant

+ 24V
GND
NC
NC

24V

Mains voltage

Lighting system with emergency lighting

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

397

INTERFACE Analog
MACX Analog / MCR Analog
Voltage transducers for
DC voltages up to 660 V

22,5

99

114,5

FL

U=

Power

IN

U,I

OUT

MCR-VDC-UI-B-DC
POWER

Voltage transducers for DC voltages up to 660 V DC

uPz

Housing width 22.5

IN

3-way isolation
Adjustable voltage ranges
ZERO/SPAN adjustment 20%

solid

The MCR-VDC-UI-B-DC voltage


transducers can be used to record voltage
values between 0... 20 V DC and
0... 660 V DC in several signal ranges and
to convert them into standardized analog
signals.
The signal ranges are selected via the
input screw terminal blocks, in part by
jumpers. An adjustment of 20% allows
you to define the range end value within the
signal range individually.

Pluggable screw
connection

stranded
[mm2]
0.2-2.5
0.2-2.5

550V
370V
250V
170V
AWG
24-14

Screw
M3

Description

Technical data
Input data
Input voltage range/resistance

IN

1 U1

6 U6

2 U2

7 U7

MCR-VDC-UI-B-DC

OUT

13

+ 24V

14

GND 2

11

GND 3

8 GND 1 4 U4

GND 2

12

ZERO

+ 24V

3 U3

SPAN

9
10

2811116

Surge voltage category / pollution degree


Test voltage input/output
Degree of protection
Ambient temperature range
Housing material
Conformance / approvals
Conformity

18.5 V DC ... 30.2 V DC


< 50 mA
< 1% (of end value)
< 0.015%/K
40 Hz
12 ms
acc. to EN 50178
150 V DC (to earth)
II / 2
1.5 kV (50 Hz, 1 min.)
IP20
-25C ... 50C
Polyamide PA non-reinforced
CE compliant

16

24V

Mains voltage

Voltage measurement in case of ungrounded circuits

PHOENIX CONTACT

MCR-VDC-UI-B-DC

Tachometer generator

398

J
J
J

Order No.

15

GND 3

13 + 24VDC
14 + 24VDC
15 GND3
16 GND3

Type

POWER

Power

24V DC

5 U5

5
6

-550 V DC ... 550 V DC


-370 V DC ... 370 V DC
-250 V DC ... 250 V DC
-170 V DC ... 170 V DC
-120 V DC ... 120 V DC
-80 V DC ... 80 V DC
-54 V DC ... 54 V DC
-36 V DC ... 36 V DC
-24 V DC ... 24 V DC
20% / 20%
U output
-10 ... 10 V
15 V
> 10 k
< 50 mVPP

Rated insulation voltage

10V

9 OUT I
10 OUT U
11 GND2
12 GND2

Pcs. /
Pkt.

MCR voltage transducer, for DC voltages from 0... 20 V DC to


0... 660 V DC

ZERO / SPAN adjustment


Output data
Output signal
Maximum output signal
Load RB
Ripple
General data
Supply voltage UB
Current consumption
Transmission error, max.
Temperature coefficient
Limit frequency (3 dB)
Step response (10-90%)
Safe isolation

Control system

120V
80V
54V
36V
24V
GND 1

OUT

1
2
3
4

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

550 k
370 k
250 k
170 k
120 k
80 k
54 k
36 k
24 k
I output
-20 ... 20 mA
30 mA
< 500
< 50 mVPP

INTERFACE Analog
MACX Analog / MCR Analog
Voltage transducers for
sinusoidal AC voltages of up to 440 V

22,5

99

Power

114,5

FL

U,I

IN

OUT

MCR-VAC-UI-O-DC
POWER

Voltage transducer for sinusoidal AC voltages of up to 440 V AC

uPz

Housing width 22.5

IN

3-way isolation
TRMS measurement
Adjustable voltage ranges
ZERO/SPAN adjustment 20%

solid

Pluggable screw
connection

The MCR-VAC-UI-0-DC voltage


transducers can be used to measure voltage
values between 0...20 V AC and 0...440 V
AC in several signal ranges and to convert
them into standard analog signals.
The signal ranges are selected via the
input screw terminal blocks, in part by
jumpers. An adjustment of 20% allows
you to define the range end value within the
signal range individually.

stranded
[mm2]
0.2-2.5
0.2-2.5

AWG
24-14

Screw
M3

Description

Technical data
Input data
Input voltage range/resistance

IN

MCR-VAC-UI-O-DC

OUT

5
6
7

13 + 24VDC
14 + 24VDC
15 GND3
16 GND3

J
J

Type

Order No.

MCR-VAC-UI-O-DC

2811103

Pcs. /
Pkt.

370 k
250 k
170 k
120 k
80 k
54 k
36 k
24 k

I output
0 ... 20 mA / 4 ... 20 mA
30 mA
< 500
< 50 mVPP

18.5 V DC ... 30.2 V DC


< 45 mA
< 1.5% (of end value)
Typ. 0.02%/K (50/60 Hz)
250 ms
acc. to EN 50178
300 V AC (to earth)
III / 2
3.3 kV (50 Hz, 1 min.)
3.3 kV (50 Hz, 1 min.)
1 kV (50 Hz, 1 min.)
IP20
-25C ... 60C
Polyamide PA non-reinforced
CE compliant

POWER

7 U7

3 U3

GND 2

8 GND 1 4 U4

GND 2

ZERO

2 U2

SPAN

1 U1

6 U6

Power

5 U5

+ 24V

13

10

+ 24V

14

11

GND 3

12

L1
L2
L3
N

0-80V
0-54V
0-36V
0-24V
GND 1

0 V ... 370 V AC
0 V ... 250 V AC
0 V ... 170 V AC
0 V ... 120 V AC
0 V ... 80 V AC
0 V ... 54 V AC
0 V ... 36 V AC
0 V ... 24 V AC
20% / 20%
45 Hz ... 400 Hz
U output
0 ... 10 V
15 V
> 10 k
< 50 mVPP

Rated insulation voltage


Surge voltage category / pollution degree
Test voltage input/output
Test voltage input/power supply
Test voltage output/power supply
Degree of protection
Ambient temperature range
Housing material
Conformance / approvals
Conformity

4...20mA

9 OUT I
10 OUT U
11 GND2
12 GND2

MCR voltage transducer, for sinusoidal AC voltages from


0...20 V AC to 0...440 V AC

ZERO / SPAN adjustment


Frequency range
Output data
Output signal
Maximum output signal
Load RB
Ripple
General data
Supply voltage UB
Current consumption
Transmission error, max.
Temperature coefficient
Step response (10-90%)
Safe isolation

Control system

OUT

0-370V 1
0-250V 2
0-170V 3
0-120V 4

15
16

GND 3

24V

Mains voltage

Voltage measurement in case of grounded circuits

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

399

INTERFACE Analog
PACT Analog

PACT Analog current transformers

400

PHOENIX CONTACT

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

INTERFACE Analog

Power

PACT Analog

Power:
Bus-bar current transformers
Plug-in current transformers
Winding current transformers

Minimum constructional depth


All converters have a uniform width of
30 mm.
Flexible use
The primary rail support is removable
and thus allows flat installation directly on
the copper rail. This is the starting point
for space-saving applications.

The current transformers are


available in calibration-capable and
non-calibration-capable versions.

Variable mounting options


One of these space-saving applications
is, for instance, current measurement in
branch exits.
The conductive connection of a copper
rail with another is implemented using a
copper sleeve. It is inserted into the inner
hole of the horizontal current
transformer.

Minimum constructional depth

Flexible use

PACT Analog current transformers


offer safe isolation
The PACT Analog current transformers
are tested as per the EN 50178 standard
("Electronic equipment for use in electrical
power installations"). The main topics of
the EN 50178 are safety and reliability.
The current transformers are tested
with an impulse withstand voltage of 12 kV
due to the safe isolation required. The
amplitude of the impulse withstand voltage
is rated for double isolation (safe isolation)
of network circuits from the environment
as per surge voltage category 3. The
amount of the impulse withstand voltage
results in a maximum permissible rated
insulation voltage of 1000 V.

Safe isolation prevents sparkovers from


occurring at the secondary side of the
current transformer. A voltage dangerous
to human beings can thus not advance into
other electrical components. There is no
hazard for human beings - within as well as
outside the control cabinet.

Variable mounting options

Professional connection method


E.g. Ethernet

SELV =
Safety extra low voltage

Safe isolation

Current transducers
(e.g. MACX MCR-SL-CAC-5-I)

Controllers

Motor
Up to 1 kV

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

401

INTERFACE Analog
PACT Analog

PACT Analog - The range of current transformers for versatile mounting


With PACT Analog, Phoenix Contact
offers a complete range of rod, plug-on
and wound type current transformers for
measuring high currents ranging between
1 A and 4000 A.
These high-quality current
transformers are available in almost
3000 different designs. You can choose
from different accuracy classes, capacities
and sizes depending on your application.
First, the type of transformer suitable
for the specified copper rail dimensions
is determined.
Then the four electrical features of the
transformer are defined on the basis of
the given selection table according to
the order key:
1.The primary rated current strength Ipn,
the current strength occurring most
frequently in the application path to be
measured.
2.The secondary rated current Isn that is
supplied to the downstream measuring
devices.
3.The class (accuracy) for adherence to
the specified tolerances.
4.The rated power Sn (in VA), in which all
the occurring loads of the measuring
circuit are considered.

Order key for PACT MCR-V2-3015-60 (example)


On-stock types that can be ordered directly have been marked in green in the selection table.
Order No.
2277271

Primary current Ipn


/
IP00600
IP00750
IP00800
IP01000
IP01250
IP02000
IP02500

Determination of the secondary side rated power Sn


All the occurring loads must be added:
Calculate the power requirement of the copper cable (supply and
return line)
Take into account the power requirement of the connected devices
(measuring devices)
Add a reserve requirement

=
=
=
=
=
=
=

Power requirement of copper cables with a different


diameter

IS05

60 A
75 A
80 A
100 A
125 A
200 A
250 A

Class
/

IS01 = 1 A
IS05 = 5 A

Secondary current Isn


1A

0.2917
0.1750
0.1094
0.0729

0.117
0.0070
0.0044
0.0029

Isn

Cl.

2.

Primary rated current strength Ipn [A]


60
75
80
100
125
150
1.25
2.5
2.5

0.5
1A

1.25

2.5

2.5

2.5

2.5
3.75

2.5
5

Example:
Copper cable Sn = cable length x 2 x rated power
Copper cable Sn = 10 m x 2 x 0.1750 VA/m = 3.50 VA
0.5

200
2.5
3.75

250
2.5
5

2.5
5

2.5
5
7.5

2.5
3.75

2.5
5

1.25
1

1.25
1.5

1.25
2

2.5

2.5
3.75

2.5
3.75
5

2.5
5
7.5

2.5
5
7.5
10

Total Sn = copper cable Sn + measuring device Sn + reserve Sn


Total Sn = 3.5 VA + 2 VA + 2 VA = 7.5 VA

402

PHOENIX CONTACT

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

P750
P125
P250
P375
P500
P750
P1000

3.

Measuring device Sn = 2 VA
5A

C02 = 0.2
C05 = 0.5
C10 = 1

Rated power Sn [VA]

Secondary current Isn


5A

Reserve Sn < 0.5 x (copper cable Sn + measuring device Sn)


Reserve Sn = 2 VA

Rated power Sn

C10

Selection table (extract)

Rated power in VA/m


(Observe the supply and the return line)

1.5
2.5
4
6

1.

Total Sn = copper cable Sn + measuring device Sn + reserve Sn

Conductor crosssection in mm2

Secondary current Isn

IP02000

=
=
=
=
=
=

1.25 VA
2.5 VA
3.75 VA
5.0 VA
7.5 VA
10 VA

4.

INTERFACE Analog
PACT Analog
Current transformers

21

16

PACT MCR-V1-21-44-...
Bus-bar current transformer

Housing width 30
Rated power
Sn

Description

Preferred versions available from stock


(marked in green in the selection table)
Primary rated current Ipn:
- 50 A
1.25 VA
- 75 A
2.5 VA
- 100 A
2.5 VA
- 150 A
5 VA
- 250 A
5 VA
- 400 A
5 VA
Current transformers, pay attention to the following ordering key
for determining the desired current transformer type

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

Order No.

PACT MCR-V1-21-44- 50-5A-1


PACT MCR-V1-21-44- 75-5A-1
PACT MCR-V1-21-44-100-5A-1
PACT MCR-V1-21-44-150-5A-1
PACT MCR-V1-21-44-250-5A-1
PACT MCR-V1-21-44-400-5A-1

2277019
2277611
2277022
2277035
2277048
2277051

1
1
1
1
1
1

PACT MCR-V1- 21- 44

2277268

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5
1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
44 / 30 / 66 mm
30 / 44 / 66 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
2277268

IP05000

IS01

Selection table PACT MCR-V1-21-44 (Order No.: 2277268)


Primary rated current strength Ipn [A]
Isn
Cl.
50
60
75
80
100
125
1.25
2.5
C05
= 0.5
IS01
=1A
1.25
1.25
2.5
2.5
2.5
2.5
C10
3.75
=1

C05
= 0.5
IS05
=5 A

1.25
C10
=1

1.25
1.5

2.5

Pcs. /
Pkt.

Type

2.5

C05

Rated power Sn
/

P1000

150
2.5
3.75

200
2.5
5

250
2.5
5
7.5

300
2.5
5

400
2.5
5
7.5

500
2.5
5
10

2.5
5

2.5
5

2.5
5
7.5

2.5
5

2.5
5
7.5

2.5
5
10

1.25
1.5

1.25
2.0

1.25
2.5

2.5
3.75

2.5
5
7.5

2.5
5
10

2.5
5
7.5

2.5
5
7.5

2.5

2.5
3.75

2.5
5

2.5
5
7.5

2.5
5
7.5

2.5
5
10

2.5
5
7.5

2.5
5
10

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

Rated power Sn [VA]

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.
The relevant installation accessories can be found on page 419.

50

Due to their primary rail holder that can


be pulled out, the PACT analog current
transformers are suitable for horizontal and
vertical installation. It is thus possible to
place current transformers in parallel
directly on the copper rail. This is
particularly convenient in the case of spacecritical applications.

30

44

26

PACT MCR-V1-21-44
Primary rated current Ipn:
0...(50...500) A
Round conductor dimensions: 21 mm

403

INTERFACE Analog
PACT Analog
Current transformers

28

23x23

16x33

16

PACT MCR-V2-3015-60-...
Plug-in current transformer

Housing width 30
Rated power
Sn

Description

Preferred versions available from stock


(marked in green in the selection table)
Primary rated current Ipn:
- 100 A
2.5 VA
- 125 A
3.75 VA
- 150 A
5 VA
- 200 A
5 VA
- 250 A
10 VA
- 300 A
7.5 VA
- 400 A
10 VA
- 500 A
10 VA
- 600 A
10 VA
- 750 A
10 VA
Current transformers, pay attention to the following ordering key
for determining the desired current transformer type

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

Order No.

PACT MCR-V2-3015- 60- 100-5A-1


PACT MCR-V2-3015- 60- 125-5A-1
PACT MCR-V2-3015- 60- 150-5A-1
PACT MCR-V2-3015- 60- 200-5A-1
PACT MCR-V2-3015- 60- 250-5A-1
PACT MCR-V2-3015- 60- 300-5A-1
PACT MCR-V2-3015- 60- 400-5A-1
PACT MCR-V2-3015- 60- 500-5A-1
PACT MCR-V2-3015- 60- 600-5A-1
PACT MCR-V2-3015- 60- 750-5A-1

2277064
2277624
2277077
2277637
2277080
2277640
2277093
2277653
2277103
2277666

1
1
1
1
1
1
1
1
1
1

PACT MCR-V2-3015- 60

2277271

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5
1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
60 / 30 / 80 mm
30 / 60 / 80 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
2277271

IP07500

IS01

Selection table PACT MCR-V2-3015-60 (Order No.: 2277271)


Primary rated current strength Ipn [A]
Isn
Cl.
50
60
75
80
100
125
1.25
2.5
C05
= 0.5
IS01
=1 A
1.25
1.25
2.5
2.5
2.5
2.5
C10
3.75
=1

1.25
C10
=1

404

PHOENIX CONTACT

1.25
1.5

1.25
2

2.5

2.5
3.75

C05

Rated power Sn
/

P1500

150
2.5

200
2.5
3.75

250
2.5
5

300
2.5
5
7.5

400
2.5
5
10

500
2.5
5
10

2.5
5

2.5
5

2.5
5
7.5

2.5
5
10

2.5
5
10

2.5
5
10

2.5
3.75

2.5
5

2.5
5
7.5

2.5
5
10

2.5
5
7.5

2.5
5
7.5
10

2.5
5
7.5
10

2.5
5
10
15

C05
= 0.5
IS05
=5A

Pcs. /
Pkt.

Type

2.5
3.75
5

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

2.5
5
10

600
2.5
5
10
15
2.5
5
10
15
2.5
5
10

750
2.5
5
10
15
5
10
15
20
2.5
5
10

2.5
5
10

2.5
5
10

2.5
5
10
15

Rated power Sn [VA]

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.
The relevant installation accessories can be found on page 419.

64

Due to their primary rail holder that can


be pulled out, the PACT analog current
transformers are suitable for horizontal and
vertical installation. It is thus possible to
place current transformers in parallel
directly on the copper rail. This is
particularly convenient in the case of spacecritical applications.

30

60

33x16

PACT MCR-V2-3015-60
Primary rated current Ipn:
0...(50...750) A
Round conductor dimensions: 28 mm
Rail dimensions:
30x15 mm; 20x20 mm

INTERFACE Analog
PACT Analog
Current transformers

13x40,5

33

PACT MCR-V2-4012-70-...
Plug-in current transformer

Housing width 30
Rated power
Sn

Description

Preferred versions available from stock


(marked in green in the selection table)
Primary rated current Ipn:
- 250 A
5 VA
- 300 A
7.5 VA
- 400 A
7.5 VA
- 500 A
10 VA
- 600 A
10 VA
- 750 A
10 VA
- 800 A
10 VA
- 1000 A
10 VA
Current transformers, pay attention to the following ordering key
for determining the desired current transformer type

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

Order No.

PACT MCR-V2-4012- 70- 250-5A-1


PACT MCR-V2-4012- 70- 300-5A-1
PACT MCR-V2-4012- 70- 400-5A-1
PACT MCR-V2-4012- 70- 500-5A-1
PACT MCR-V2-4012- 70- 600-5A-1
PACT MCR-V2-4012- 70- 750-5A-1
PACT MCR-V2-4012- 70- 800-5A-1
PACT MCR-V2-4012- 70-1000-5A-1

2277116
2277679
2277129
2277682
2277132
2277695
2277145
2277158

1
1
1
1
1
1
1
1

PACT MCR-V2-4012- 70

2277284

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5
1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
70 / 30 / 90 mm
30 / 70 / 90 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
2277284

IP010000

IS05

Selection table PACT MCR-V2-4012-70 (Order No.: 2277284)


Primary rated current strength Ipn [A]
Isn
Cl.
75
80
100
125
150
200
1.25
2.5
2.5
C05
3.75
= 0.5
IS01
=1 A
1.25
1.25
2.5
2.5
2.5
2.5
C10
3.75
5
5
=1

1.25
C10
=1

1.25

2.5

C10

Rated power Sn
/

P250

250
2.5
5

300
2.5
5

400
2.5
5
7.5

500
2.5
5
10

600
2.5
5
10

750
2.5
5
10

2.5
5
7.5

2.5
5
10

2.5
5
10

2.5
5
10

2.5
5
10

2.5
5
10
15
2.5
5
10

1.25

2.5

2.5
3.75

2.5
5

2.5
5

2.5
5
7.5

2.5
5
10

2.5
5
10

2.5
3.75

2.5
5

2.5
5

2.5
5
7.5

2.5
5
7.5

2.5
5
7.5

2.5
5
10

2.5
5
10

C05
= 0.5
IS05
=5A

Pcs. /
Pkt.

Type

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

2.5
5
10
15

800
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

1000
2.5
5
10
2.5
5
10
2.5
5
10

Rated power Sn [VA]

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.
The relevant installation accessories can be found on page 419.

31x31

74

Due to their primary rail holder that can


be pulled out, the PACT analog current
transformers are suitable for horizontal and
vertical installation. It is thus possible to
place current transformers in parallel
directly on the copper rail. This is
particularly convenient in the case of spacecritical applications.

30

16

70

40,5x13

PACT MCR-V2-4012-70
Primary rated current Ipn:
0...(75...1000) A
Round conductor dimensions: 33 mm
Rail dimensions:
40x12 mm; 2x 30x10 mm

2.5
5
10

PHOENIX CONTACT

405

INTERFACE Analog
PACT Analog
Current transformers

42

41x31

31x41

PACT MCR-V2-5012-85-...
Plug-in current transformer

Housing width 30
Rated power
Sn

Description

Preferred versions available from stock


(marked in green in the selection table)
Primary rated current Ipn:
- 400 A
10 VA
- 600 A
10 VA
- 800 A
10 VA
- 1000 A
15 VA
- 1250 A
15 VA
Current transformers, pay attention to the following ordering key
for determining the desired current transformer type

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

Order No.

PACT MCR-V2-5012- 85- 400-5A-1


PACT MCR-V2-5012- 85- 600-5A-1
PACT MCR-V2-5012- 85- 800-5A-1
PACT MCR-V2-5012- 85-1000-5A-1
PACT MCR-V2-5012- 85-1250-5A-1

2277161
2277174
2277187
2277190
2277200

1
1
1
1
1

PACT MCR-V2- 5012- 85

2277297

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5
1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
85 / 30 / 108 mm
30 / 85 / 108 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
2277297

IP02500

IS01

Selection table PACT MCR-V2-5012-85 (Order No.: 2277297)


Primary rated current strength Ipn [A]
Isn
Cl.
100
125
150
200
250
300
1.25
2.5
2.5
2.5
C05
5
5
5
= 0.5
7.5
IS01
=1 A

1.25

2.5

C10
=1

2.5
3.75

2.5
5
7.5

1.25

2.5
5

2.5
3.75

2.5
5
7.5

C05
= 0.5
IS05
=5A

1.25
C10
=1

406

PHOENIX CONTACT

2.5

Pcs. /
Pkt.

Type

2.5
5
7.5
10
2.5
5

2.5
5
10

2.5
5
7.5
10

2.5
5
10

2.5
5
7.5

400
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

C10

500
2.5
5
10
15
2.5
5
10
20
2.5
5
10
15
5
10
15
20

Rated power Sn
/

600
2.5
5
10
15
2.5
5
10
20
2.5
5
20
15
5
10
15
20

P750

750
2.5
5
10

800
2.5
5
10

2.5
5
10

2.5
5
10
15
2.5
5
10

2.5
5
10
2.5
5
10

2.5
5
10
15

1000
2.5
5
10
15
5
10
15
20
2.5
5
10
15
5
10
15
20

1250
2.5
5
10
15
5
10
15
20
2.5
5
10
15
5
10
15
20

1500
2.5
5
10
15
5
10
15
30
2.5
5
10
15
5
10
15
20

Rated power Sn [VA]

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.
The relevant installation accessories can be found on page 419.

13x50,5

16
92

Due to their primary rail holder that can


be pulled out, the PACT analog current
transformers are suitable for horizontal and
vertical installation. It is thus possible to
place current transformers in parallel
directly on the copper rail. This is
particularly convenient in the case of spacecritical applications.

30

85

50,5x13

PACT MCR-V2-5012-85
Primary rated current Ipn:
0...(100...1500) A
Round conductor dimensions: 42 mm
Rail dimensions:
50x12 mm; 2x 40x10 mm

INTERFACE Analog
PACT Analog
Current transformers

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.
The relevant installation accessories can be found on page 419.

53

32x54

54x32

42x42

105

16x64

16

30

PACT MCR-V2-6315-95-...
Plug-in current transformer

Housing width 30
Rated power
Sn

Description

Preferred versions available from stock


(marked in green in the selection table)
Primary rated current Ipn:
- 800 A
10 VA
- 1000 A
10 VA
- 1250 A
10 VA
- 1500 A
10 VA
- 1600 A
10 VA
Current transformers, pay attention to the following ordering key
for determining the desired current transformer type

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

Order No.

PACT MCR-V2-6315- 95- 800-5A-1


PACT MCR-V2-6315- 95-1000-5A-1
PACT MCR-V2-6315- 95-1250-5A-1
PACT MCR-V2-6315- 95-1500-5A-1
PACT MCR-V2-6315- 95-1600-5A-1

2277213
2277226
2277239
2277242
2277255

1
1
1
1
1

PACT MCR-V2- 6315- 95

2277307

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5
1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
95 / 30 / 121 mm
30 / 95 / 121 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
2277307

IP25000

IS05

Selection table PACT MCR-V2-6315-95 (Order No.: 2277307)


Primary rated current strength Ipn [A]
Isn
Cl.
200
250
300
400
500
600
2.5
2.5
2.5
2.5
2.5
2.5
C05
5
5
5
5
= 0.5
7.5
10
10
IS01
=1 A
C10
=1

2.5
3.75

2.5
5

2.5
5
7.5

2.5
5
10

2.5
5
10

2.5

2.5
3.75

2.5
5
7.5

2.5
5
10

2.5
3.75

2.5
5

2.5
5
10

2.5
5
10
15

2.5
5
10
15
5
10
15
20

C05
= 0.5
IS05
=5A
C10
=1

Pcs. /
Pkt.

Type

2.5
5
10
15
2.5
5
10
15
5
10
15
20

C05

Rated power Sn
/

P500

750
5
10
15

800
5
10
15

1000
5
10

1250
5
10

1500
5
10
15

1600
5
10
15

5
10
15

5
10
15
20
5
10
15
20
5
10
15
30

5
10

5
10

5
10
15

5
10
15
30
10
15
30

5
10
15
20
5
10
15
30

5
10
15
30
5
10
15
30

5
10
15
20
5
10
15
30

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

2500

5
10
15

2000
5
10
15
20
10
15
20

5
10
15
30
10
15
30

5
10
15
30
10
15
30

5
10
15
30
10
15
30

PHOENIX CONTACT

Rated power Sn [VA]

Due to their primary rail holder that can


be pulled out, the PACT analog current
transformers are suitable for horizontal and
vertical installation. It is thus possible to
place current transformers in parallel
directly on the copper rail. This is
particularly convenient in the case of spacecritical applications.

95

64x16

PACT MCR-V2-6315-95
Primary rated current Ipn:
0...(200...2500) A
Round conductor dimensions: 53 mm
Rail dimensions:
63x15 mm
2x 50x10 mm
40x40 mm

407

INTERFACE Analog
PACT Analog
Current transformers

PACT MCR-V2-6015-85
Primary rated current Ipn:
0...(200...1600) A
Round conductor dimensions: 52 mm
Rail dimensions:
60x15 mm; 2x 50x10 mm; 40x40 mm
PACT MCR-V2-6040-96
Primary rated current Ipn:
0...(200...2000) A
Round conductor dimensions: 61 mm
Rail dimensions:
60x40 mm; 50x50 mm

Housing width 30

96
16

Pcs. /
Pkt.

PACT MCR-V2- 6015- 85

2277336

Technical data
Input data
Thermal rated short-time current
Ith = 60 * In
Rated surge current
Idyn = 2.5 * Ith
Rated frequency
50 Hz ... 60 Hz
Surge current limitation factor
FS 5
General data
Rated insulation voltage
1 kV
Test voltage
3 kV (50 Hz, 1 min.)
Can be calibrated
No
Insulating material class
E
Connection capacity of secondary terminals
2 x (2.5 x 4) mm
Ambient temperature (operation)
-25C ... 40C
Standards/regulations
IEC 60044-1
Housing material
Polyamide PA glass fiber reinforced
Dimensions L / W / H
85 / 30 / 108 mm
Dimensions (alternative assembly) L / B / H
30 / 85 / 108 mm
Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
Rated power Sn
IP05000

IS01

C10

C05
= 0.5
IS05
=5A

2.5

1.25 1.25 1.25


2.5

2.5
5

2.5
5
10

2.5
5
10

2.5

2.5
5

2.5
5
10

2.5
5
10

2.5

C10
=1

408

PHOENIX CONTACT

2.5

2.5
5
10
15
2.5
5
10
15

2.5
5
10
15
5
10
15

5
10
15
20
5
10
15
20

5
10
15
20
5
10
15
30

61

Pcs. /
Pkt.

Type

Order No.

PACT MCR-V2-6040- 96-1000-5A-1


PACT MCR-V2-6040- 96-1500-5A-1

2277705
2277718

1
1

PACT MCR-V2- 6040- 96

2277349

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5
1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
96 / 30 / 121 mm
30 / 96 / 121 mm

P375

Selection table PACT MCR-V2-6015-85 (Order No.: 2277336)


Primary rated current strength Ipn [A]
Isn
Cl.
200 250 300 400 500 600 750 800 1000 1250 1500 1600
1.25 1.25 1.25 2.5 2.5 2.5 2.5 2.5 2.5
C05
5
5
= 0.5
IS01
=1 A
2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
C10
3.75
5
3.75 3.75
5
=1
5
10
15
5
10
15

Rated power Sn [VA]

44x64

105

Order No.

54x54

52

42x42

52x32

32x52

16x60,5

16
92

Type

Preferred versions available from stock


(marked in green in the selection table)
Primary rated current Ipn:
- 1000 A
10 VA
- 1500 A
10 VA
Current transformers, pay attention to the following ordering key
for determining the desired current transformer type

2277336

30

30

Selection table PACT MCR-V2-6040-96 (Order No.: 2277349)


Primary rated current strength Ipn [A]
Isn
Cl.
200 250 300 400 500 600 750 800 1000 1250 1500 1600 2000
2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
C05
5
5
5
5
5
5
5
= 0.5
7.5
7.5 7.5
10
10
IS01
=1 A
2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
C10 3.75
5
5
5
5
5
5
5
5
5
5
=1
7.5 7.5
7.5 7.5
10
10
2.5

2.5

2.5
5

2.5
5
7.5

2.5
5
7.5

2.5
5
10

2.5
5
10

2.5
5
7.5

2.5
5
10

2.5
5
10

2.5 2.5
3.75 3.75

2.5
5

2.5
5
7.5

2.5
5
7.5

2.5
5
10

2.5
5
10

2.5
5
10
15

2.5
5
10

5
10
15

2.5
5
10

C05
= 0.5
IS05
=5A
C10
=1

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

2.5
5
10
15
5
10
15

5
10
15
5
10
15

Rated power Sn [VA]

Rated power
Sn

Plug-in current transformer

85

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.

Description

PACT MCR-V2-6040- 96

Plug-in current transformer

Housing width 30

60,5x16

Due to their primary rail holder that can


be pulled out, the PACT analog current
transformers are suitable for horizontal and
vertical installation. It is thus possible to
place current transformers in parallel
directly on the copper rail. This is
particularly convenient in the case of spacecritical applications.

PACT MCR-V2-6015- 85

INTERFACE Analog
PACT Analog
Current transformers

PACT MCR-V2-8015-105
Primary rated current Ipn:
0...(400...2500) A
Round conductor dimensions: 61 mm
Rail dimensions:
80x15 mm; 2x 60x10 mm; 3x 50x10 mm
PACT MCR-V2-8020-105
Primary rated current Ipn:
0...(500...2000) A
Round conductor dimensions: 70 mm
Rail dimensions:
2x 80x10 mm; 60x60 mm

Preferred versions available from stock


(marked in green in the selection table)
Primary rated current Ipn:
- 1000 A
10 VA
- 1500 A
15 VA
Current transformers, pay attention to the following ordering key
for determining the desired current transformer type

Housing width 30

30

PACT MCR-V2-8015-105-1000-5A-1
PACT MCR-V2-8015-105-1500-5A-1

2277721
2277734

PACT MCR-V2-8015-105

2277352

Pcs. /
Pkt.

IP25000

IS05

C10

31x81

70

Pcs. /
Pkt.

Type

Order No.

1
1

PACT MCR-V2-8020-105-1000-5A-1
PACT MCR-V2-8020-105-1500-5A-1

2277747
2277750

1
1

PACT MCR-V2- 8020-105

2277365

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5
1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
105 / 30 / 132 mm
30 / 105 / 132 mm

P3000
Selection table PACT MCR-V2-8020-105 (Order No.: 2277365)
Primary rated current strength Ipn [A]
Isn
Cl.
500 600 750 800 1000 1250 1500 1600 2000
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
C05
5
5
5
5
5
5
= 0.5
10
IS01
Rated power Sn [VA]

Selection table PACT MCR-V2-8015-105 (Order No.: 2277352)


Primary rated current strength Ipn [A]
Isn
Cl.
400 500 600 750 800 1000 1250 1500 1600 2000 2500
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
5
C05
5
5
5
5
5
5
5
5
10
= 0.5
10
10
7.5
10
10
10
15
IS01
15
15
20
=1 A
2.5
2.5
2.5
2.5
2.5
2.5
2.5
5
5
10
C10
5
5
5
5
5
5
5
10
10
15
=1
7.5
10
10
10
10
10
10
15
15
20
15
15
20
20
25
2.5
2.5
2.5
2.5
2.5
5
2.5
2.5
2.5
2.5
5
C05
5
5
5
5
5
10
5
5
5
5
10
= 0.5
10
10
10
15
10
10
10
10
15
IS05
15
15
20
15
15
20
=5A
2.5
2.5
2.5
2.5
5
5
2.5
2.5
5
5
10
C10
5
5
5
5
10
10
5
5
10
10
15
=1
7.5
10
10
10
15
15
10
10
15
15
20
15
20
15
20
30

60x64

16
116

Order No.

64x53

61

33x63

16x83

16

Type

Technical data
Input data
Thermal rated short-time current
Ith = 60 * In
Rated surge current
Idyn = 2.5 * Ith
Rated frequency
50 Hz ... 60 Hz
Surge current limitation factor
FS 5
General data
Rated insulation voltage
1 kV
Test voltage
3 kV (50 Hz, 1 min.)
Can be calibrated
No
Insulating material class
E
Connection capacity of secondary terminals
2 x (2.5 x 4) mm
Ambient temperature (operation)
-25C ... 40C
Standards/regulations
IEC 60044-1
Housing material
Polyamide PA glass fiber reinforced
Dimensions L / W / H
105 / 30 / 132 mm
Dimensions (alternative assembly) L / B / H
30 / 105 / 132 mm
Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
Rated power Sn
2277352

30

105

=1 A
C10
=1

C05
= 0.5
IS05
=5A
C10
=1

2.5
5

2.5
5
7.5

2.5
5
7.5

2.5
5
7.5

2.5
5

2.5
5

2.5
5

2.5
5
7.5

2.5
5
10
15
2.5
5
10

2.5
5

2.5
5
7.5

2.5
5
7.5

2.5
5
10

2.5
5
10

2.5
5
10

2.5
5
10

2.5
5
10

2.5
5
10
15

2.5
5
10
15
5
10
15

2.5
5

2.5
5
7.5

2.5
5
7.5

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

2.5
5
10

Rated power Sn [VA]

Rated power
Sn

Description

Plug-in current transformer

105

116

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.

PACT MCR-V2-8020-105

Plug-in current transformer

Housing width 30

53x53

Due to their primary rail holder that can


be pulled out, the PACT analog current
transformers are suitable for horizontal and
vertical installation. It is thus possible to
place current transformers in parallel
directly on the copper rail. This is
particularly convenient in the case of spacecritical applications.

PACT MCR-V2-8015-105

5
10

PHOENIX CONTACT

409

INTERFACE Analog
PACT Analog
Current transformers

PACT MCR-V2-10020-129
Primary rated current Ipn:
0...(400...4000) A
Round conductor dimensions: 85 mm
Rail dimensions:
2x 100x10 mm; 80x64 mm
PACT MCR-V2-10036-129
Primary rated current Ipn:
0...(400...4000) A
Rail dimensions:
3x 100x12 mm

Plug-in current transformer

Housing width 30

Housing width 30

30

30

140

Type

Order No.

PACT MCR-V2-10020-129

2277378

Pcs. /
Pkt.

56x101

85

140

64x84

31x101

16

129

16

129

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.

Description

PACT MCR-V2-10036-129

Plug-in current transformer

81x54

Due to their primary rail holder that can


be pulled out, the PACT analog current
transformers are suitable for horizontal and
vertical installation. It is thus possible to
place current transformers in parallel
directly on the copper rail. This is
particularly convenient in the case of spacecritical applications.

PACT MCR-V2-10020-129

Type

Order No.

PACT MCR-V2-10036-129

2277381

Pcs. /
Pkt.

Current transformers, pay attention to the following ordering key


for determining the desired current transformer type

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5

1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
129 / 30 / 156 mm
30 / 129 / 156 mm

1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
129 / 30 / 156 mm
30 / 129 / 156 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
/

IP40000

IS05

C05

Rated power Sn
/

Selection table PACT MCR-V2-10020-129 (Order No.: 2277378)


Primary rated current strength Ipn [A]
Isn
Cl.
400 500 600 750 800 1000 1250 1500 1600 2000 2500 3000 4000
2.5
5
5
5
5
5
5
5
5
5
5
C05
5
10
10
10
10
10
10
10
10
10
10
= 0.5
15
15
15
15
15
15
IS01
20
20
=1 A
2.5 2.5
5
5
5
5
5
5
5
5
5
5
C10
5
5
10
10
10
10
10
10
10
10
10
10
=1
15
15
15
15
15
15
25
30
2.5 2.5
5
5
5
5
5
5
5
5
5
5
C05
5
5
10
10
10
10
10
10
10
10
10
10
= 0.5
15
15
15
15
15
15
15
IS05
20
20
25
25
=5A
2.5 2.5
5
5
5
5
5
5
5
5
5
5
5
C10
5
5
10
10
10
10
10
10
10
10
10
10
10
=1
15
15
15
15
15
15
15
15
20
25
30
30
30

410

PHOENIX CONTACT

P2500
Selection table PACT MCR-V2-10036-129 (Order No.: 2277381)
Primary rated current strength Ipn [A]
Isn
Cl.
400 500 600 750 800 1000 1250 1500 1600 2000 2500 3000 4000
2.5
5
5
5
5
5
5
5
5
5
5
C05
5
10
10
10
10
10
10
10
10
10
10
= 0.5
15
15
15
15
15
15
IS01
20
20
=1 A
2.5 2.5
5
5
5
5
5
5
5
5
5
5
C10
5
5
10
10
10
10
10
10
10
10
10
10
=1
15
15
15
15
15
15
25
30
2.5 2.5
5
5
5
5
5
5
5
5
5
5
C05
5
5
10
10
10
10
10
10
10
10
10
10
= 0.5
15
15
15
15
15
15
15
IS05
20
20
25
25
=5A
2.5 2.5
5
5
5
5
5
5
5
5
5
5
5
C10
5
5
10
10
10
10
10
10
10
10
10
10
10
=1
15
15
15
15
15
15
15
15
20
25
30
30
30

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Rated power Sn [VA]

2277378

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5

Rated power Sn [VA]

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

INTERFACE Analog
PACT Analog
Current transformers

PACT MCR-V2-12020-159
Primary rated current Ipn:
0...(400...4000) A
Round conductor dimensions: 96 mm
Rail dimensions:
2x 120x10 mm; 3x 100x10 mm;
80x80 mm
PACT MCR-V2-12040-159
Primary rated current Ipn:
0...(400...4000) A
Rail dimensions:
4x 120x10 mm

Plug-in current transformer

Housing width 30

30

30

172

Type

Order No.

PACT MCR-V2-12020-159

2277394

Pcs. /
Pkt.

72x122

96

55x103

172

34x126

16

159

16

159

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.

Description

PACT MCR-V2-12040-159

Plug-in current transformer

Housing width 30

83x83

Due to their primary rail holder that can


be pulled out, the PACT analog current
transformers are suitable for horizontal and
vertical installation. It is thus possible to
place current transformers in parallel
directly on the copper rail. This is
particularly convenient in the case of spacecritical applications.

PACT MCR-V2-12020-159

Type

Order No.

PACT MCR-V2-12040-159

2277404

Pcs. /
Pkt.

Current transformers, pay attention to the following ordering key


for determining the desired current transformer type

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5

1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
159 / 30 / 188 mm
30 / 159 / 188 mm

1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
159 / 30 / 188 mm
30 / 159 / 188 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
/

IP08000

IS01

C05

Rated power
/

Selection table PACT MCR-V2-12020-159 (Order No.: 2277394)


Primary rated current strength Ipn [A]
Isn
Cl.
400 500 600 750 800 1000 1250 1500 1600 2000 2500 3000 4000
2.5 2.5 2.5 2.5 2.5 2.5
5
5
5
5
5
5
10
C05
5
5
5
5
5
5
10
10
10
10
10
10
15
= 0.5 10
10
10
10
10
10
15
15
15
15
15
15
30
IS01
15
20
30
30
30
30
30
45
=1 A
2.5
5
5
2.5 2.5
5
5
5
5
5
5
10
10
C10
5
10
10
5
5
10
10
10
10
10
10
15
15
=1
10
15
15
10
10
15
15
15
15
15
15
30
30
15
20
20
15
20
30
30
30
30
30
45
45
2.5 2.5 2.5 2.5 2.5
5
5
10
5
5
5
10
10
C05
5
5
5
5
5
10
10
15
10
10
10
15
15
= 0.5 10
10
10
10
10
15
15
30
15
15
15
30
30
IS05
15
15
30
30
45
30
30
30
45
45
=5A
2.5
5
5
5
5
5
5
10
5
5
10
10
10
C10
5
10
10
10
10
10
10
15
10
10
15
15
15
=1
10
15
15
15
15
15
15
30
15
15
30
30
30
15
20
20
20
30
30
30
45
30
30
45
45
45

P250
Selection table PACT MCR-V2-12040-159 (Order No.: 2277404)
Primary rated current strength Ipn [A]
Isn
Cl.
400 500 600 750 800 1000 1250 1500 1600 2000 2500 3000 4000
2.5 2.5 2.5 2.5 2.5 2.5
5
5
5
5
5
5
10
C05
5
5
5
5
5
5
10
10
10
10
10
10
15
= 0.5
10
15
15
15
15
15
15
30
IS01
=1 A
C10
=1

C05
= 0.5
IS05
=5A
C10
=1

2.5
5
10

5
10
15

5
10
15

2.5
5

2.5
5
10

5
10
15

5
10
15

5
10
15

5
10
15

5
10
15

5
10
15

10
15
30

10
15
30

2.5
5

2.5
5

2.5
5

2.5
5
10

2.5
5
10

5
10
15

5
10
15

10
15
30

5
10
15

5
10
15

5
10
15

10
15
30

10
15
30

2.5
5
10

5
10
15

5
10
15

5
10
15

5
10
15

5
10
15

5
10
15

10
15
30

5
10
15

5
10
15

10
15
30

10
15
30

10
15
30

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

Rated power Sn [VA]

2277404

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5

Rated power Sn [VA]

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

411

INTERFACE Analog
PACT Analog
Current transformers

PACT MCR-V3-60
Primary rated current Ipn:
0...(1...40) A

30

The PACT analog current transformer as


winding current transformer has a special
structure: the current-carrying copper lines
are directly connected to the screw
terminal blocks on the primary side.
Depending on the transformation ratio,
the output current can have higher values
than the input current.

64

16

60

PACT MCR-V3-60
Winding current transformer

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.
The relevant installation accessories can be found on page 419.

Housing width 30
Description

Type

Order No.

PACT MCR-V3- 60

2277417

Pcs. /
Pkt.

Current transformers, pay attention to the following ordering key


for determining the desired current transformer type

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz ... 60 Hz
FS 5
1 kV
3 kV (50 Hz, 1 min.)
No
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
60 / 30 / 80 mm
30 / 60 / 80 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
/

IP00025

IS01

Selection table PACT MCR-V3-60 (Order No.: 2277417)


Primary rated current strength Ipn [A]
Isn
Cl.
1
2
2.5
4
5
2.5
2.5
2.5
2.5
2.5
C05
5
5
5
5
5
= 0.5
IS01
=1 A
2.5
2.5
2.5
2.5
2.5
C10
5
5
5
5
5
=1

C05
= 0.5
IS05
=5A
C10
=1

412

PHOENIX CONTACT

C10

Rated power Sn
/

P250

6
2.5
5

7.5
2.5
5

10
2.5
5

12.5
2.5
5

15
2.5
5

20
2.5
5

25
2.5
5

30
2.5
5

40
2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

2.5
5

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

Rated power Sn [VA]

2277417

INTERFACE Analog
PACT Analog
Current transformers that can be
calibrated
PACT MCR-V1C-21-44
Primary rated current Ipn:
0...(150...500) A
Round conductor dimensions: 21 mm
PACT MCR-V2C_3015_60
Primary rated current Ipn:
0...(200...750) A
Round conductor dimensions: 28 mm
Rail dimensions:
30x15 mm; 20x20 mm

PACT MCR-V2C-3015-60

Bus-bar current transformer

Plug-in current transformer

Housing width 30

Housing width 30

30

30

60

28

23x23

26

50

21

64

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.
The relevant installation accessories can be found on page 419.

16x33

16

16

44

33x16

PACT analog current transformers have


to undergo a type approval test after the
successful completion of which they may be
calibrated. The current transformers that
can be calibrated become calibrated only
after an additional calibration process is
executed.

PACT MCR-V1C-21-44

Description

Type

Order No.

PACT MCR-V1C-21-44

2277420

Pcs. /
Pkt.

Type

Order No.

PACT MCR-V2C-3015-60

2277433

Pcs. /
Pkt.

Current transformers, pay attention to the following ordering key


for determining the desired current transformer type

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5

1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
44 / 30 / 66 mm
30 / 44 / 66 mm

1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
60 / 30 / 80 mm
30 / 60 / 80 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
/

IP03000

IS05

2277420 =
PACT MCR-V1C-21-44

IS05 = 5 A

Selection table PACT MCR-V1C-21-44 (Order No.: 2277420)


Primary rated current strength Ipn [A]
Isn
Cl.
150
200
250
300
400
500
2.5
2.5
2.5
5
5
5
0.2
5A
2.5
0.5

2.5
5

2.5
5

2.5
5
10

2.5
5

2.5
5
10

C02

Rated power Sn
/
P250
P500
P1000
P1500

C02 = 0.2
C05 = 0.5

Rated power Sn
[VA]

2277420

=
=
=
=

Calibration

P250
2.5 VA
5.0 VA
10 VA
15 VA

Certificate of calibration

NONE

NONE = Not calibrated


YES = Calibrated

Selection table PACT MCR-V2C-3015-60 (Order No.: 2277433)


Primary rated current strength Ipn [A]
Isn
Cl.
200
250
300
400
500
600
750
2.5
2.5
2.5
2.5
5
5
5
0.2
10
10
5A
2.5
0.5

2.5
5

2.5
5

2.5
5
10

2.5
5
10

2.5
5
10

2.5
5
10
15

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

NONE
= No certificate of calibration
= Certificate of calibration (at a
charge)
YESPLUS = Certificate of calibration with
catalog of errors (five measuring
points) (at a charge)
NONE
YES

Rated power Sn
[VA]

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

PHOENIX CONTACT

413

INTERFACE Analog
PACT Analog
Current transformers that can be
calibrated
PACT MCR-V2C-4012-70
Primary rated current Ipn:
0...(200...1000) A
Round conductor dimensions: 33 mm
Rail dimensions:
40x12 mm; 2x 30x10 mm
PACT MCR-V2C-5012-85
Primary rated current Ipn:
0...(200...1200) A
Round conductor dimensions: 42 mm
Rail dimensions:
50x12 mm; 2x 40x10 mm

PACT MCR-V2C-5012- 85

Plug-in current transformer

Plug-in current transformer

Housing width 30

Housing width 30

30

30

85

33

13x50,5

42

2277446

41x31

PACT MCR-V2C- 4012- 70

Pcs. /
Pkt.

31x41

Order No.

92

Type

50,5x13

Description

31x31

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.

74

13x40,5

16

16

70

40,5x13

PACT analog current transformers have


to undergo a type approval test after the
successful completion of which they may be
calibrated. The current transformers that
can be calibrated become calibrated only
after an additional calibration process is
executed.

PACT MCR-V2C-4012- 70

Type

Order No.

PACT MCR-V2C- 5012- 85

2277459

Pcs. /
Pkt.

Current transformers, pay attention to the following ordering key


for determining the desired current transformer type

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5

1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
70 / 30 / 90 mm
30 / 70 / 90 mm

1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
85 / 30 / 108 mm
30 / 85 / 108 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
/

IP10000

IS05

2277459 =
PACT MCR-V2C-5012-85

IS05 = 5 A

C02 = 0.2
C05 = 0.5

Selection table PACT MCR-V2C-4012-70 (Order No.: 2277446)


Primary rated current strength Ipn [A]
Isn
Cl.
200 250 300 400 500 600 750 800
2.5
2.5
2.5
5
2.5
5
5
5
10
5
0.2
10
10
10

1000
5
10

5A
2.5
0.5

414

2.5
5

2.5
5

PHOENIX CONTACT

2.5
5
10

2.5
5
10

5
10

5
10

C05

2.5
5
10

5
10

Rated power Sn
[VA]

2277459

Rated power Sn
/
P250
P500
P1000
P1500
P3000

=
=
=
=
=

Calibration

P1500
2.5 VA
5.0 VA
10 VA
15 VA
30 V A

Certificate of calibration

NONE

NONE
= No certificate of calibration
= Certificate of calibration (at a
charge)
YESPLUS = Certificate of calibration with
catalog of errors (five measuring
points) (at a charge)
NONE
YES

NONE = Not calibrated


YES = Calibrated

Selection table PACT MCR-V2C-5012-85 (Order No.: 2277459)


Primary rated current strength Ipn [A]
Isn
Cl.
200 250 300 400 500 600 750 800
2.5
2.5
2.5
2.5
2.5
5
5
5
5
5
0.2
10
10
10
5A
2.5
0.5

2.5
5

2.5
5

2.5
5
10

2.5
5
10

5
10

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

5
10

5
10

1000
5
10
15
30
5
10
15
30

1200
5
10
15
30
5
10
15
30

Rated power Sn
[VA]

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

INTERFACE Analog
PACT Analog
Current transformers that can be
calibrated
PACT MCR-V2C-6015-85
Primary rated current Ipn:
0...(250...1200) A
Round conductor dimensions: 52 mm
Rail dimensions:
60x15 mm; 2x 50x10 mm; 40x40 mm
PACT MCR-V2C-6015-95
Primary rated current Ipn:
0...(200...1500) A
Round conductor dimensions: 53 mm
Rail dimensions:
60x15 mm; 2x 50x10 mm; 40x40 mm

PACT MCR-V2C-6015- 95

Plug-in current transformer

Plug-in current transformer

Housing width 30

Housing width 30

95

30

30

52

53

16x64

2277462

32x54

PACT MCR-V2C-6015- 85

Pcs. /
Pkt.

54x32

Order No.

42x42

Type

105

Description

64x16

42x42

32x52

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.

92

52x32

16x60,5

16

16

85

60,5x16

PACT analog current transformers have


to undergo a type approval test after the
successful completion of which they may be
calibrated. The current transformers that
can be calibrated become calibrated only
after an additional calibration process is
executed.

PACT MCR-V2C-6015- 85

Type

Order No.

PACT MCR-V2C- 6015- 95

2277475

Pcs. /
Pkt.

Current transformers, pay attention to the following ordering key


for determining the desired current transformer type

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5

1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
85 / 30 / 108 mm
30 / 85 / 108 mm

1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
95 / 30 / 121 mm
30 / 95 / 121 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
/

IP02500

IS05

2277462 =
PACT MCR-V2C-6015-85

IS05 = 5 A

5A
2.5

2.5

2.5

2.5
5

2.5
5

2.5
5
10

2.5
5
10

C02 = 0.2
C05 = 0.5

Selection table PACT MCR-V2C-6015-85 (Order No.: 2277462)


Primary rated current strength Ipn [A]
Isn
Cl.
250
300
400
500
600
750
800 1000
2.5
2.5
2.5
2.5
5
5
5
0.2
10

0.5

Rated power Sn

C05

2.5
5
10
15

1200
2.5
5
10
15
2.5
5
10
15

Rated power Sn
[VA]

2277462

P250
P500
P1000
P1500
P2000
P3000

=
=
=
=
=
=

P250
2.5 VA
5.0 VA
10 VA
15 VA
20 V A
30 V A

Calibration
/

NONE
NONE = Not calibrated
YES = Calibrated

Certificate of calibration
/

NONE
= No certificate of calibration
= Certificate of calibration (at a
charge)
YESPLUS = Certificate of calibration with
catalog of errors (five measuring
points) (at a charge)
NONE
YES

Selection table PACT MCR-V2C-6015-95 (Order No.: 2277475)


Primary rated current strength Ipn [A]
Isn
Cl.
200 250 300 400 500 600 750 800 1000
2.5 2.5 2.5 2.5 2.5
5
5
5
5
5
5
10
0.2
10
10
10
15
15
15
20
5A
2.5 2.5 2.5 2.5 2.5 2.5
5
5
5
5
5
5
5
5
10
10
10
0.5
10
10
10
15
15
15
15
15
15
20
30
30

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

1200
5
10
15
20
5
10
15
20

1250
5
10
15
20
5
10
15
30

1500
5
10
15
30
5
10
15
30

Rated power Sn
[VA]

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

PHOENIX CONTACT

415

INTERFACE Analog
PACT Analog
Current transformers that can be
calibrated
PACT MCR-V2C-6040-96
Primary rated current Ipn:
0...(500...1500) A
Round conductor dimensions: 61 mm
Rail dimensions:
60x40 mm; 50x50 mm
PACT MCR-V2C-8015-105
Primary rated current Ipn:
0...(400...1500) A
Round conductor dimensions: 61 mm
Rail dimensions:
80x15 mm; 2x 60x10 mm; 3x 50x10 mm

Plug-in current transformer

Housing width 30

Housing width 30

96

30

30

16

105

Order No.

PACT MCR-V2C- 6040- 96

2277488

Pcs. /
Pkt.

61

33x63

116

Type

53x53

61

44x64

16x83

16
105

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.

Description

PACT MCR-V2C-8015-105

Plug-in current transformer

54x54

PACT analog current transformers have


to undergo a type approval test after the
successful completion of which they may be
calibrated. The current transformers that
can be calibrated become calibrated only
after an additional calibration process is
executed.

PACT MCR-V2C-6040- 96

Type

Order No.

PACT MCR-V2C-8015-105

2277491

Pcs. /
Pkt.

Current transformers, pay attention to the following ordering key


for determining the desired current transformer type

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5

1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
96 / 30 / 121 mm
30 / 96 / 121 mm

1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
105 / 30 / 132 mm
30 / 105 / 132 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
/

IP12000

2277488 =
PACT MCR-V2C-6040-96

IS05

IS05 = 5 A

Selection table PACT MCR-V2C-6040-96 (Order No.: 2277488)


Primary rated current strength Ipn [A]
Isn
Cl.
500
600
750
800 1000 1200 1250 1500
2.5
2.5
2.5
2.5
2.5
2.5
5
5
5
5
5
5
0.2
10
10
15
5A
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
5
5
5
5
5
5
5
5
0.5
10
10
10
10
10
10
15
15

416

PHOENIX CONTACT

Rated power Sn

C02

C02 = 0.2
C05 = 0.5

Rated power Sn
[VA]

2277488

P250
P500
P1000
P1500
P2000

=
=
=
=
=

P1000
2.5 VA
5.0 VA
10 VA
15 VA
20 V A

Calibration
/

NONE
NONE = Not calibrated
YES = Calibrated

Certificate of calibration
/

NONE
= No certificate of calibration
= Certificate of calibration (at a
charge)
YESPLUS = Certificate of calibration with
catalog of errors (five measuring
points) (at a charge)
NONE
YES

Selection table PACT MCR-V2C-8015-105 (Order No.: 2277491)


Primary rated current strength Ipn [A]
Isn
Cl.
400
500
600
750
800 1000 1200 1250
2.5
2.5
2.5
2.5
2.5
2.5
5
5
5
5
5
5
0.2
10
10
10
10
10
15
5A
2.5
2.5
2.5
2.5
2.5
5
2.5
2.5
5
5
5
5
5
10
5
5
0.5
10
10
10
15
10
10
15
15
20

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

1500
2.5
5
10
15
2.5
5
10
15

Rated power Sn
[VA]

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

INTERFACE Analog
PACT Analog
Current transformers that can be
calibrated
PACT MCR-V2C-8020-105
Primary rated current Ipn:
0...(400...1500) A
Round conductor dimensions: 70 mm
Rail dimensions:
2x 80x10 mm; 60x60 mm
PACT MCR-V2C-10020-129
Primary rated current Ipn:
0...(500...2500) A
Round conductor dimensions: 85 mm
Rail dimensions:
2x 100x10 mm; 80x64 mm

Description

Plug-in current transformer

Housing width 30

Housing width 30

30

30

129

Order No.

PACT MCR-V2C-8020-105

2277501

Pcs. /
Pkt.

85

64x84

140

Type

81x54

70

31x81

60x64

31x101

16

16

105

116

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.

PACT MCR-V2C-10020-129

Plug-in current transformer

64x53

PACT analog current transformers have


to undergo a type approval test after the
successful completion of which they may be
calibrated. The current transformers that
can be calibrated become calibrated only
after an additional calibration process is
executed.

PACT MCR-V2C-8020-105

Type

Order No.

PACT MCR-V2C-10020-129

2277514

Pcs. /
Pkt.

Current transformers, pay attention to the following ordering key


for determining the desired current transformer type

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5

1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
105 / 30 / 132 mm
30 / 105 / 132 mm

1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
129 / 30 / 156 mm
30 / 129 / 156 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary current Ipn
Secondary current Isn
Class
/

IP08000

IS05

2277514 =
PACT MCR-V2C-10020-129

IS05 = 5 A

5A
2.5
5

2.5
5

2.5
5

2.5
5

2.5
5
10

2.5
5
10

2.5
5
10

C02 = 0.2
C05 = 0.5

Selection table PACT MCR-V2C-8020-105 (Order No.: 2277501)


Primary rated current strength Ipn [A]
Isn
Cl.
400 500 600 750 800 1000 1200 1250 1500
2.5 2.5 2.5
2.5
2.5
2.5
2.5
5
5
5
5
0.2
10
10
10

0.5

Rated power Sn

C05

2.5
5
10

2.5
5
10

Rated power Sn
[VA]

2277514

P250
P500
P1000
P1500

=
=
=
=

P1500
2.5 VA
5.0 VA
10 VA
15 VA

Calibration
/

NONE
NONE = Not calibrated
YES = Calibrated

Certificate of calibration
/

NONE
= No certificate of calibration
= Certificate of calibration (at a
charge)
YESPLUS = Certificate of calibration with
catalog of errors (five measuring
points) (at a charge)
NONE
YES

Selection table PACT MCR-V2C-10020-129 (Order No.: 2277514)


Primary rated current strength Ipn [A]
Isn
Cl.
500 600 750 800 1000 1200 1250 1500
2.5
2.5
2.5
2.5
5
5
5
5
0.2
10
10
10
10
15
15
5A
2.5 2.5 2.5 2.5
2.5
2.5
2.5
2.5
5
5
5
5
5
5
5
5
0.5
10
10
10
10
10
10
15
15
15
15
15

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

1600
2.5
5
10
15
2.5
5
10
15

2000
2.5
5
10
15
2.5
5
10
15

2500
2.5
5
10
15
2.5
5
10
15

Rated power Sn
[VA]

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

PHOENIX CONTACT

417

INTERFACE Analog
PACT Analog
Current transformers that can be
calibrated
PACT MCR-V2C-10039-129
Primary rated current Ipn:
0...(500...2500) A
Rail dimensions:
3x 100x12 mm

30

Note:
Our configurator provides you with a convenient ordering option
under www.phoenixcontact.de/eshop.
The relevant installation accessories can be found on page 419.

140

PACT analog current transformers have


to undergo a type approval test after the
successful completion of which they may be
calibrated. The current transformers that
can be calibrated become calibrated only
after an additional calibration process is
executed.

56x101

16

129

PACT MCR-V2C-10036-129
Plug-in current transformer

Housing width 30
Description

Type

Order No.

PACT MCR-V2C-10036-129

2277527

Pcs. /
Pkt.

Current transformers, pay attention to the following ordering key


for determining the desired current transformer type

Technical data
Input data
Thermal rated short-time current
Rated surge current
Rated frequency
Surge current limitation factor
General data
Rated insulation voltage
Test voltage
Can be calibrated
Insulating material class
Connection capacity of secondary terminals
Ambient temperature (operation)
Standards/regulations
Housing material
Dimensions L / W / H
Dimensions (alternative assembly) L / B / H

Ith = 60 * In
Idyn = 2.5 * Ith
50 Hz
FS 5
1 kV
3 kV (50 Hz, 1 min.)
Yes
E
2 x (2.5 x 4) mm
-25C ... 40C
IEC 60044-1
Polyamide PA glass fiber reinforced
129 / 30 / 156 mm
30 / 129 / 156 mm

Add to order key from the selection table (ordering example marked in orange)
Order No.
Primary
Secondary Class
Rated power Sn
Calibration
current Ipn current Isn
/ IP16000 /

2277527 =
PACT MCRV2C-10036-129

IS05
IS05 = 5 A

C05
C02 = 0.2
C05 = 0.5

P500
P250 = 2.5 VA
P500 = 5.0 VA
P1000 = 10 VA
P1500 = 15 VA

Selection table PACT MCR-V2C-10036-129 (Order No.: 2277527)


Primary rated current strength Ipn [A]
Isn
Cl.
500 600 750 800 1000 1200 1250 1500
2.5
2.5
2.5
2.5
5
5
5
5
0.2
10
10
10
10
15
5A
2.5 2.5 2.5 2.5
2.5
2.5
2.5
2.5
5
5
5
5
5
5
5
5
0.5
10
10
10
10
10
10
15
15

418

PHOENIX CONTACT

1600
2.5
5
10
15
2.5
5
10
15

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

NONE
/
NONE = Not
calibrated

Certificate of calibration

NONE
YES

YES = Calibrated

2000
2.5
5
10
15
2.5
5
10
15

2500
2.5
5
10
15
2.5
5
10
15

Rated power Sn
[VA]

2277527

NONE
= No certificate of
calibration
= Certificate of
calibration
(at a charge)

YESPLUS = Certificate of
calibration with
catalog of errors
(five measuring
points)
(at a charge)

INTERFACE Analog
PACT Analog
PACT analog current transformer
Accessories
Copper sleeves
Secondary terminal cover

PACT MCR-CB-...
Description

Type

Order No.

PACT MCR-CB-21- 8
PACT MCR-CB-21-12
PACT MCR-CB-28-12
PACT MCR-CB-42-12

2277569
2277556
2277543
2277530

PACT MCR-ETC-...
Pcs. /
Pkt.

Type

Order No.

PACT MCR-ETC-60
PACT MCR-ETC-75

2277572
2277585

Pcs. /
Pkt.

Copper sleeves, for establishing a conductive connection during


the horizontal assembly of PACT analog current transformers. The
size of the copper sleeve depends on the diameter of the inner hole
of the current transformer.
- for PACT MCR-V1-21-44-...
21/8 mm
- for PACT MCR-V1-21-44-...
21/12 mm
- for PACT MCR-V2-3015-60-...
28/12 mm
- for PACT MCR-V2-5012-85-...
42/12 mm
Secondary terminal cover, for increasing the clearances and
creepage distances
- for PACT MCR-V1-21-44-...
Length: 60 mm
- for PACT MCR-V2-3015-60-...
Length: 75 mm
and PACT MCR-V2-5012-85-...

1
1
1
1

9
9

PACT analog current transformer


Accessories
DIN rail adapter
Insulating caps

PACT MCR-RA
Description

PACT MCR-ICAP

Type

Order No.

Pcs. /
Pkt.

PACT MCR-RA

2277598

12

Type

Order No.

Pcs. /
Pkt.

PACT MCR-ICAP

2277608

18

DIN rail adapter


Insulating caps, for protection against unintended contact with
mounting screws of the primary rail

Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108


info@powermation.com - 800-843-9859 - www.powermation.com

PHOENIX CONTACT

419

Vous aimerez peut-être aussi