Académique Documents
Professionnel Documents
Culture Documents
Spreadsheets to BS 8110
Client
Location
Advisory Group
First Floor Column C
INTERNAL
BO
COLUMN Checked
MATERIALS
DIMENSIONS
LOADING
SLAB
fcu N/mm2 35
fyv N/mm2 460
link mm 10
A
B
G
Vt
ult UDL
h
STATUS
VALID DESIGN
mm
mm
kN
kN/m2
563
16.10
3397.1
mm
mm
mm
259
230.5
244.75
mm
300
dx
dy
ave d
RESULTS
Veff = 647.5 kN
At col. face, v max = 3.689 N/mm2
6 T10 @ 350
9 T10 @ 345
12 T10 @ 345
0
0
0
0
0
0
mm
mm
Revision
1
Job No
43091
Legend
E
F
H
mm
Page
25-Feb-2015
chg
200
300
1000
mm
Date
100
-50
1000
vc =
At 1.5d perimeter, v =
At 3d perimeter, v =
.
122 from col face
306 from col face
490 from col face
0
0
0
0
0
0
Plan
N/mm2
N/mm2
N/mm2
(Table 3.8)
Project
Spreadsheets to BS 8110
Client
Location
Advisory Group
Column B2
EDGE
BO
COLUMN Checked
MATERIALS
fcu N/mm2 40
fyv N/mm2 460
link
8
mm
DIMENSIONS
LOADING
SLAB
A
B
D
Vt
ult UDL
h
mm
mm
mm
kN
kN/m2
mm
STATUS
VALID DESIGN
223
14.40
250
Perimeter 1
Perimeter 2
0
0
0
0
0
0
0
6 T8 @ 220
7 T8 @ 265
0
0
0
0
0
0
0
mm
-62.5
-275
150
125
1399
dx
dy
ave d
RESULTS
Veff = 312.2 kN
At col. face, v max = 1.976 N/mm2
mm
mm
mm
mm
mm
Revision
2
Job No
43091
Legend
E
F
G
H
mm
Page
25-Feb-2015
chg
200
200
50
Date
207
187
197
vc =
At 1.5d perimeter, v =
At 2.25d perimeter, v =
.
98 from col face
246 from col face
0
0
0
0
0
0
0
Plan
0.8032
1.0364
0.7813
N/mm2
N/mm2
N/mm2
(Table 3.8)
Project
Spreadsheets to BS 8110
Client
Advisory Group
Location
CORNER
COLUMN Checked
Made by
MATERIALS
fcu N/mm2 40
fyv N/mm2 460
link mm 8
DIMENSIONS
LOADING
A
B
C
D
Vt
ult UDL
SLAB
mm
mm
mm
mm
kN
kN/m2
mm
STATUS
VALID DESIGN
E
F
G
H
mm
mm
-50
-250
100
100
272.0
16.10
350
mm
mm
215
195
205
250
dx
dy
ave d
6
8
5
6
7
T8
T8
T8
T8
T8
@
@
@
@
@
0
0
0
0
140
125
275
265
265
mm
mm
Date
Page
25-Feb-2015
Revision
3
Job No
43091
Legend
400
250
0
0
mm
BO
chg
RESULTS
Veff = 340.0 kN
At hole face, vmax = 2.745 N/mm2
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
vc =
At 1.5d perimeter, v =
At 4.5d perimeter, v =
.
102 from col face
256 from col face
410 from col face
564 from col face
717.5 from col face
0
0
0
0
Plan
0.8686
1.6585
0.7741
N/mm2
N/mm2
N/mm2
(Table 3.8)
Project
Spreadsheets to BS 8110
Client
Location
Advisory Group
An example
RE-ENTRANT
BO
CORNER Checked
MATERIALS
fcu N/mm2 40
fyv N/mm2 460
link mm 10
DIMENSIONS
LOADING
SLAB
A
B
C
D
Vt
ult UDL
h
mm
mm
mm
mm
kN
kN/m2
mm
STATUS
VALID DESIGN
E
F
G
H
mm
447.0
14.40
250
dx
dy
ave d
RESULTS
Veff = 558.8 kN
At col. face, v max = 2.534 N/mm2
6 T10 @ 220
8 T10 @ 255
0
0
0
0
0
0
0
mm
mm
mm
mm
mm
mm
Page
25-Feb-2015
Revision
chg
350
350
0
0
Date
4
Job No
43091
Legend
-125
-425
250
250
591.6
202
180
191
vc =
At 1.5d perimeter, v =
At 2.25d perimeter, v =
.
95 from col face
239 from col face
0
0
0
0
0
0
0
Plan
0.9841
1.1738
0.9209
N/mm2
N/mm2
N/mm2
(Table 3.8)
Project
Spreadsheets to BS 8110
Location
INTERNAL COLUMN
Made by BO
1999-2003 BCA for Date
Job No 43091
25-Feb-15
DETAILED CALCULATIONS
Veff/Vt
1.1500
CRITICAL PERIMETERS
Per No
a
1
367.125
2
550.6875
3
734.25
4
917.8125
5
1101.375
6
1284.9375
7
1468.5
8
1652.0625
Hole face
0
Col face
0
LINK REQUIREMENTS
Per No
v
1
0.9274
2
0.6594
3
0.5013
4
0.3953
5
0.3179
6
0.2581
7
0.2098
8
0.1694
Hole face
3.6894
Col face
3.6894
LINK PERIMETERS
Per No
a
1
122.375
2
305.9375
3
489.5
4
673.0625
5
856.625
6
1040.1875
7
1223.75
8
1407.3125
9
1590.875
(enhancement factor)
Internal
3937
5405.5
6874
8342.5
9811
11279.5
12748
14216.5
1000
1000
deduct
1163
1603
2043
2482
2922
3361
3801
4240
284
284
Asv
620
850
1080
1310
1540
1769
1999
2229
Total No
7.89
10.82
0.00
0.00
0.00
0.00
0.00
0.00
Location
1.50 d
2.25 d
3.00 d
0.00 d
0.00 d
0.00 d
0.00 d
0.00 d
within
Band?
0
0
0
0
0
0
0
0
Internal
1979
3447.5
4916
6384.5
7853
9321.5
10790
12258.5
13727
deduct
577
1017
1456
1896
2336
2775
3215
3654
4094
Final
1402
2431
3460
4488
5517
6546
7575
8604
9633
No
6
9
12
15
18
20
23
26
29
Spacing
350
345
345
345
340
360
360
355
355
Project
Spreadsheets to BS 8110
Location
Column B2
EDGE COLUMN
Made by BO
1999-2003 BCA for RCC
Job No 43091
Date
25-Feb-15
DETAILED CALCULATIONS
Veff/Vt
1.4000
CRITICAL PERIMETERS
Per No
a
1
295.5
2
443.25
3
591
4
738.75
5
886.5
6
1034.25
7
1182
8
1329.75
Hole face
25
Col face
0
LINK REQUIREMENTS
Per No
v
1
1.0364
2
0.7813
3
0.6177
4
0.5025
5
0.4158
6
0.3475
7
0.2916
8
0.2446
Hole face
1.8039
Col face
1.9758
LINK PERIMETERS
Per No
a
1
98.5
2
246.25
3
394
4
541.75
5
689.5
6
837.25
7
985
8
1132.75
9
1280.5
(enhancement factor)
Internal
3164
4346
5528
6710
7892
9074
10256
11438
1000
Choose
1882
2473
3064
3655
4246
4837
5428
6019
1000
800
Final
1487
1930
2373
2816
3260
3703
4146
4589
875
800
Asv
267
347
427
507
586
666
746
825
Total No
5.32
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Location
1.50 d
2.25 d
0.00 d
0.00 d
0.00 d
0.00 d
0.00 d
0.00 d
within
Band?
1
0
0
0
0
0
0
0
Internal
1588
2770
3952
5134
6316
7498
8680
9862
11044
Choose
1094
1685
2276
2867
3458
4049
4640
5231
5822
deduct
199
346
494
642
790
937
1085
1233
1381
Final
896
1339
1782
2225
2669
3112
3555
3998
4442
ENCLOSED
Per No
1
2
3
4
5
6
7
8
Hole face
Col face
No
6
7
9
10
12
13
15
16
18
Spacing
220
265
250
275
265
280
270
285
275
AREAS
Edge D
0.431
0.753
1.162
1.659
2.242
2.913
3.672
4.517
0.063
0.040
Project
Spreadsheets to BS 8110
Location
CORNER COLUMN
Made by BO
Job No 43091
Date
25-Feb-15
DETAILED CALCULATIONS
Veff/Vt 1.2500 (enhancement factor) link leg area 50.3
Hole deduction ? YES
CRITICAL PERIMETERS
Per No
a
Internal Edge C Edge D Corner Choose deduct
1
307.5
3760
2280
2130
1265
1265
288
2
461.25
4990
2895
2745
1572.5 1572.5
391
3
615
6220
3510
3360
1880
1880
447
4
768.75
7450
4125
3975
2187.5 2187.5
498
5
922.5
8680
4740
4590
2495
2495
549
6
1076.25 9910
5355
5205
2802.5 2802.5
600
7
1230
11140 5970
5820
3110
3110
652
8
1383.75 12370 6585
6435
3417.5 3417.5
703
Hole face
25
1500
1150
1000
700
700
100
Col face
0
650
650
0
ENCLOSED AREAS
Per No
Corner
1
0.394
2
0.613
3
0.878
4
1.191
5
1.551
6
1.958
7
2.412
8
2.914
Hole face 0.117
Col face 0.100
LINK REQUIREMENTS
Per No
v
Asv
1
1.659
668
2
1.353
268
3
1.097
268
4
0.912
316
5
0.774
364
6
0.666
412
7
0.578
460
8
0.506
508
Hole face 2.745
Col face 2.536
LINK PERIMETERS
Per No
a
Internal Edge C Edge D
1
102.5
2120
1460
1310
2
256.25
3350
2075
1925
3
410
4580
2690
2540
4
563.75
5810
3305
3155
5
717.5
7040
3920
3770
6
871.25
8270
4535
4385
7
1025
9500
5150
5000
8
1178.75 10730 5765
5615
9
1332.5 11960 6380
6230
Final
977
1182
1433
1690
1946
2202
2458
2715
600
650
within
Total No LocationBand?
13.3
1.50 d
1
5.3
2.25 d
1
5.3
3.00 d
1
6.3
3.75 d
1
0.0
4.50 d
0
0.0
0.00 d
0
0.0
0.00 d
0
0.0
0.00 d
0
Final
703
908
1113
1348
1604
1860
2117
2373
2629
No
6
8
5
6
7
8
8
9
10
Spacing
140
125
275
265
265
265
300
295
290
Project
Spreadsheets to BS 8110
Location
An example
Made by BO
1999-2003 BCA for RCC
Job No 43091
Date
25-Feb-15
DETAILED CALCULATIONS
Veff/Vt
1.2500
(enhancement factor)
CRITICAL PERIMETERS
Per No
a
Internal
1
286.5
3692
2
429.75
4838
3
573
5984
4
716.25
7130
5
859.5
8276
6
1002.75
9422
7
1146
10568
8
1289.25
11714
Hole face
0
1400
Col face
0
LINK REQUIREMENTS
Per No
v
1
1.1738
2
0.9209
3
0.7548
4
0.6370
5
0.5488
6
0.4801
7
0.4249
8
0.3794
Hole face 2.5338
Col face
2.5338
LINK PERIMETERS
Per No
a
1
95.5
2
238.75
3
382
4
525.25
5
668.5
6
811.75
7
955
8
1098.25
9
1241.5
Corner
3119
3978.5
4838
5697.5
6557
7416.5
8276
9135.5
1400
1400
Asv
429
543
657
772
886
1000
1114
1228
Total No
5.46
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Location
1.50 d
2.25 d
0.00 d
0.00 d
0.00 d
0.00 d
0.00 d
0.00 d
within
Band?
0
0
0
0
0
0
0
0
Internal
2164
3310
4456
5602
6748
7894
9040
10186
11332
Corner
1273
2132.5
2992
3851.5
4711
5570.5
6430
7289.5
8149
deduct
386
591
796
1000
1205
1410
1614
1819
2024
Final
887
1541
2196
2851
3506
4161
4816
5471
6125
No
6
8
10
12
15
17
19
22
24
Spacing
220
255
270
285
265
275
280
270
275
Corner
0.405
0.608
0.852
1.137
1.463
1.830
2.238
2.687
0.123
0.123
Disclaimer
All advice or information from the British Cement Association and/or Reinforced Concrete
Council is intended for those who will evaluate the significance and limitations of its
contents and take responsibility for its use and application. No liability (including that for
negligence) for any loss resulting from such advice or information is accepted by the BCA,
RCC or their subcontractors, suppliers or advisors. Users should note that all BCA software
and publications are subject to revision from time to time and should therefore ensure that
they are in possession of the latest version.
Status of spreadsheet This spreadsheet is shareware. It may be distributed freely, but may
Public release version.
not be used for commercial purposes until the user has registered
with the RCC.
Date
Version
Action
r Reinforced Concrete
and limitations of its
ity (including that for
accepted by the BCA,
that all BCA software
therefore ensure that
mpanying publication
from British Cement
Size (kB)
412
409
406
417
402
421
421
404
407
310
309