Mounting Boxes
The MK Elements Collection wiring devices are designed to fit into folded metal
boxes that comply with BS 4662. To ensure products can be correctly installed, the
box must always be installed flush or sub flush to the surface to a maximum depth
of 6mm.
MK Elements Collection
Installation Guide
by Honeywell
Note: Switched Socket Outlets and Switches with built in LED locators and indicators
must be removed from the circuit before insulation testing can be carried out.
Connection
How to install
To ensure a safe installation, you must read all the installation & safety instructions
on page 1
Load/supply cables
1. Ensure the depth of the back box is correct for the product and that it is fitted
securely to the wall.
2. Install the cables in the normal way and, using the fixing screws supplied, mount
the product, without the frontplate, to the wall. It is important the correct headed
screws are used as any other may clash with the rear of the front plate. Switches
incorporating a LOOP terminal are intended for connection of unused Neutral
conductors only.
3. To optimise frontplate installation do not over tighten the screws. Adjust so the
frame and module sit squarely on the wall.
Some mounting boxes are fitted with additional threaded fixing lugs on the upper
and lower edges. It may be necessary to bend these back into the box to ensure
the frontplate sits flush with the mounting surface.
The MK Elements Euro Module wiring devices range offers a variety of clip in
modules, telephone, data connectors etc, providing the flexibility to customise a
wiring device in the same enclosure and frontplate. Care must be taken to ensure
that segregation is maintained between modules of different operating voltages in
accordance with the current edition of the IEE Wiring Regulations (BS 7671).
Carefully insert a 4mm screwdriver into the slots provided along the bottom
edge of the frontplate
Carefully twist the screwdriver and lift the frontplate away disengaging the
snap fits
Insert the conductors into the respective terminals. Where products are supplied
with backed out terminal screws, do not loosen screws further.
If the earth conductor is bare copper, ensure it is covered with a green/yellow sleeve,
so it cannot touch live parts.
Carefully push the wired product into the mounting box ensuring the cables are not
trapped or pinched.
Ensure all the terminal screws are tightened securely with a 4mm wide screwdriver.
Pull on each cable to ensure the terminal screw has securely fixed the conductor.
11.
Note:
Care should be taken to ensure product features such as snap fits are not blocked
during installation or decorating, preventing correct fitting of frontplates (for
example plaster, tile grout, paint etc).
When carrying out insulation resistance testing, first disconnect any product which
features illumination. Failing to do this could damage the product and could also
give spurious insulation readings.
Locate the top and bottom hooks on the back of the frontplate into the holes
on the top and bottom of the module
22.
Gently push along the top edge of the frontplate followed by the bottom
edge.
Products operating at extra low voltage levels (<50V) must not be mounted in the
same euro enclosures as equipment rated in excess of 50v (e.g. mains socket outlets).
Note: Ensure the correct frontplate is fitted to the correct module or frame.
RED
DND
Supply
MUR GRN
GRN
MUR
Green LED
N
DND
NUR
Red
LED
MUR
DND
COM
RED
Inside Room
Occupant Selector
2 Way & Centre Off
Red LED
DND
MUR GRN
DND
Supply
Outside Room
Bell Push/Indicator
Push to Make
GRN
MUR
RED
L
DND
Standard Compliances
Please clean the device with a dry and soft lint free cloth.
Do not use water or any abrasive solvent based or aerosol cleaners as this may
damage, discolor or affect the finish and safety of the appliance.
Please check you are fitting the correct frontplate to the correct module. The
frontplate must match the module exactly, e.g. 1 Gang Switched Socket Outlet
Frontplate will only fit a 1 Gang Switched Socket Outlet Module. Please refer to
the instructions for fitting and removing frontplates on page 4,5.
COM
Technical Help
Tel: +44 (0)1268 563720
Fax: +44 (0)1268 563064
mk.technical@honeywell.com
Customer Service
Tel: +44 (0) 1268 563000
Outside Room
Bell Push/Indicator
Push to Make
Note:
These products are suitable for use with AC mins power chime applications only. The relay
must be of suitable rating fo the circuit wiring supplying power to the chime. The relay
must have at least one normally closed contact.
Disposal
Product and packaging should be disposed of via standard refuse facilities at the
end of its useful life. Where ever possible packaging and components should be
recycled.