Académique Documents
Professionnel Documents
Culture Documents
Location
Mathura
Zone
Zone Factor ( Z ) =
Importance Factor ( I ) =
Response Reduction Factor ( R )=
Width of the structure ( d )mts=
Length of the structure ( L )mts=
Time Period =
0.16
1
3
16
25
0.023
Ta2 = 0.09/sqrt( l )
0.018
Z x I x(Sa/g)
2R
Plinth level
1 floor level
Roof level
Total
(I/R) not>1
0.027
13.277
tonnes
272.385
11.4
wxhi^2
wxhi^2
4566.375
0
35399.1546
39965.53
tonnes
13.277
tonnes
Tot.BaseShear(VB)=Alfa-hXSum(W)
Level
Alfa - h =
Z x I x(Sa/g)
2R
497.885
tonnes
Tot.BaseShear
(VB)
Enter the loads at node points for each level to get the coeff: for earthquake dist.
Level
Roof base
Node No.
86
90
94
87
91
95
88
92
96
89
93
97
Total
weight @ Node(t)
5.94
4.95
3.91
7.75
4.42
4
7.75
4.42
4
5.95
4.95
3.9
61.94
Contributory shear
0.256
0.214
0.169
0.335
0.191
0.173
0.335
0.191
0.173
0.257
0.214
0.168
2.674
Level
Roof base
Node No.
86
90
94
87
91
95
88
92
96
89
93
97
Total
weight @ Node(t)
5.94
4.95
3.91
7.75
4.42
4
7.75
4.42
4
5.95
4.95
3.9
61.94
Contributory
shear
0.256
0.214
0.169
0.335
0.191
0.173
0.335
0.191
0.173
0.257
0.214
0.168
2.674
0.33