IWU2 Independent over current relay

IWK2 Independent short current relay

IWU2/IWK2, Page 1 of 4
Distributed by
PT. SINAR ELEKTRINDO PERKASA
JL. Panjang No.7, Kedoya Elok Plaza blok DC-44 Jakarta Barat
Phone : +62-021-5806044 (Hunting); Fax : +62-021-5806058; Email : sales@sinarelektrindo.com

Application
Current Sensing are given an output contact when the current flow rise above the pread justed limit. The time lag
between measuring the over current and giving the output contact is independent on the percentage of over current.
Independent current relays are normaly used for selective triping. The other current relays are operating dependent on
percentage of overcurrent, like thermal or inverse current relay.
Example or using independent current relays:
Selective overload and short circuit protection for electrical machines and cable
Current dependent switching on and off of consumers and supplies.
Type IWU is used as over current protection and type IWK as short circuit protection. Both types are manufactured as
singel-phase or triple phase units.

Function and adjusment


Independent current relay IWU and IWK consisting of: one electronic current measuring circuit (resp. 3 circuits with
index IW. 2/3) as well as one lag circuit for the switching delay. A led indicates the position of the adjusted limit.
Current relay needs no auxilliary voltage supply.
Current range of IWU :
0.5 1.2 A Resp. 2.5 to 6 Amps. As overcurrent relay, wth a time circuit of 5 to 45 Sec
Current range of iwk: 1 4 resp. 5 to 20 amps. As shortcircuit current relay, with a time circuit of 0.1 to 0.8 sec, max 6
A continous current

Front plate

Distributed
IWU2/IWK2, Page 2 of 4
PT. SINAR ELEKTRINDO PERKASA
JL. Panjang No.7, Kedoya Elok Plaza blok DC-44 Jakarta Barat
Phone : +62-021-5806044 (Hunting); Fax : +62-021-5806058; Email : sales@sinarelektrindo.com

Technical data
Type

: IWU2 3
Triple-pole current measuring circuit (2.5 6) A,
Loadable up to rated value; with time delay (5 45) s
IWU2 3
Triple-pole current measuring circuit (5 20) A,
Continuously loadable up to 6 A; with time delay (0.1 0.8) s

Aux. supply

: Not necessary

Repeat Accuracy

: +/- 1 % at 0 to 600C

Ratio between switching on and off : 0.5 %


Consumption

: Current circuit 2.5 VA

Over voltage resistance

: Shorttime 50 %

Service life

: 105 operations

Permissible switching on time

: 100 %

Housing

: SEG-Standard case (h x w x d) 141 x 105 x 91 mm

Material

: PVC base with transparent cover

Contacts

: 660 VA, 250 V AC or 24 V DC, 2 amps.

Phase

: independent

Type of protection

: Case IP20, Terminals IP00

Weight

: 0.875 Kg.

Mounting Position

: any

Maintenance

: none

Connection diagram

Distributed
IWU2/IWK2, Page 3 of 4
PT. SINAR ELEKTRINDO PERKASA
JL. Panjang No.7, Kedoya Elok Plaza blok DC-44 Jakarta Barat
Phone : +62-021-5806044 (Hunting); Fax : +62-021-5806058; Email : sales@sinarelektrindo.com

Dimension and bore holes mm : IWU2/IWK2

Distributed
IWU2/IWK2, Page 4 of 4
PT. SINAR ELEKTRINDO PERKASA
JL. Panjang No.7, Kedoya Elok Plaza blok DC-44 Jakarta Barat
Phone : +62-021-5806044 (Hunting); Fax : +62-021-5806058; Email : sales@sinarelektrindo.com