Dear Sir/Madam,
I'm pleased to introduce you to our complete line of polymer insulated products. The attached
K-LINE INSULATORS catalogue includes the products we are currently offering to the utility
industry.
Other products are under development and will be available shortly. As these products come on
the market, we will issue you the pertinent information. In the meantime, if you require an
insulator configuration not shown in the catalogue, give us a call.
If you would like to receive updates to our catalogue, please mail us at insulators@k-line.net to
be included in our database.
We look forward to fulfilling your polymer insulator needs. Should you have any questions or
need further information, feel free to call me at (416) 292-2008.
Sincerely,
K-LINE INSULATORS LIMITED
K-LINE INSULATORS manufactures all of its products and is registered to the rigid
Quality Assurance Standards of the ISO9001 program. The company is audited on a
continuous basis by its customers and an internationally recognized quality management
auditing firm.
K-LINE INSULATORS is known for its readiness to listen to its customers' needs for
customized polymeric insulator designs that meet their special requirements. We offer
appropriate support in the proper selection of insulators to suit the application, with
training and documentation on special installation requirements. K-LINE INSULATORS
is committed to a continuous improvement policy in quality, service, delivery, and cost
reduction. Much pride comes from the innovation of new products and the continuous
improvements of present products to ensure that the insulators are the most cost effective
and have a long term system performance.
K-LINE INSULATORS approach to innovative insulator solutions is well demonstrated
and respected by its customers.
K-LINE INSULATORS people are totally dedicated to continuous quality and
performance improvement. They are dedicated to developing the best materials and
designs that lead to optimum product solutions. These characteristics amongst others,
have contributed to the success of the various strategic alliances K-LINE INSULATORS
has forged with some of its customers.
K-LINE INSULATORS is sensitive and committed to the needs of its customers and is
always prepared to give them the service they expect and deserve.
K-Line Insulators
Catalogue Number Designation of Distribution Class Insulators
Catalogue Number
Insulator
Type
Suspension/
Deadend
KL
Company
ID
Voltage Class
Material
Insulator
Type
X
End Fittings *
K-Line
15
28
35
46
69
Shed Design
A - Alternating
sheds
No A Other shed
design
Structure End
Fitting
C- Clevis
S Socket
T Tongue
Y Y-clevis
E Oval eye
S - Silicone
rubber
Line End
Fitting
T - Tongue
H - Thimble
B Ball
E Oval eye
Y Y-clevis
N/A
Line Post
N/A
N/A
K - K-clamp
V - Vertical
H - Horizontal
T - Tie-Top C
Neck
TF - Tie-Top F
Neck
E Drop Eye
Special
Variations
A - LA insulator
F Iron Fittings
IEC 16mm ball
M - Medium SML
70 kN
N - Non-standard
R - 90 aligned
end fittings
120 120 kN
A Lock washer
Al Alum base
D - Tinned alum
line fitting
G - Gain base
M20 - 20 mm
tapped
M22 - 22 mm
tapped
M24 - 24 mm
tapped
N - Non-standard
Station Post
CP - Cap &
Pin
P - Post
Railway
N/A
RW Railway
C- Clevis
S Socket
T Tongue
B Ball
Riser
A - Alternating
sheds
No A Other shed
design
RSI Riser
support
insulator
Interphase
Spacer
Guy
N/A
M12 - 12 mm
tapped
M16 - 16 mm
tapped
M20 - 20 mm
tapped
C- Clevis
S Socket
T Tongue
B Ball
U - Clamp
D - Tin plated
aluminum line
fitting
X 5/8 tapped
base
Insulated
length in
inches
N/A
N/A
N/A
C- Clevis
H - Thimble
T Tongue
R Roller
B - Threaded
T - Tongue
H - Thimble
C- Clevis
R Roller
B - Threaded
R - 90 deg turn on
end fittings
S - Silicone
Note:
* Different fittings will be designated by the addition of a number to the letter.
December 7, 2002
K-Line Insulators
Catalogue Number Designation of Transmission Class Insulators
Catalogue Number
KL
Insulator
Voltage
Type
Company
Class
ID
Suspension/
Deadend
Shed
Design
Material
Insulator
Type
H High
leakage
N/A
N/A
Line Post
K-Line
Station Post
69
115
138
161
230
End Fittings
Line End
Fitting
B - Ball
T - Tongue
Y Y Clevis
E - Eye
E -Eye
V -Vertical
H -Horizontal
Structure
End Fitting
S Socket
C- Clevis
T - Tongue
Y Y Clevis
E - Eye
G Gain base
B - Curved
BF Flat 7
BF8 Flat 8
AAlternati
ng
sheds
SSilicone
rubber
No. of
Sheds
Corona
Ring
Other
Additions
M Med ring
N No ring
#
N/A
P - Post
A - IEC
B IEC20
R 90 Deg
S SS pin
M12 - 12 mm
tapped
M16 - 16 mm
tapped
M20 - 20 mm
tapped
N - Nonstandard
December 6, 2002
K-Line Insulators
Distribution and Transmission Interphase Spacers
Insulator
Interphase
Spacer
Number of
Characters
Total
Catalogue Number
KL
Company
ID
K-Line
Insulator
Rod
Insulator
Rod
Insulator
rubber
Rod length
if
applicable
Insulator
rubber if
applicable
3-4
0-1
0-2
0-1
0-4
0-1
Rod length
P if
if
hinged
applicable
0-2
0-2
Fitting
Fittings
Special
U
U
D Tin
Universal Universal Coupler
Clamp
Clamp
length
KK
KK
M
clamp
clamp
Medium
T Tongue T Tongue
ring
C Clevis C Clevis N No
ring
L Large
ring
AAdapter
1-2
1-2
0-3
7-22
Examples:
Insulator and rod - KL46SNX25U1U1D & KLH19X30TT
Two insulators and rod(s) - KL46SNX46SNX12U1U1D & KLH13X35XH13X30PTT
Two insulators - KL28ASX15ASU1U1D6 & KLH25XH28PCC
July 3, 2002
Catalogue D-DS
PERFORMANCE BENEFITS
The performance benefits of K-Line Insulators distribution deadend/suspension insulators are listed below.
Improves Reliability (by minimizing interruptions and outages due to vandalism, pole fires, and flashovers in
all types of environments)
Eliminates or Reduces Maintenance (such as washing and trouble calls) and is compatible with existing plant
Improves Power Quality (less RI and TVI)
Energy Efficiency (lower losses due to lower leakage currents)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)
APPLICATION
Distribution deadend/suspension insulators are used on overhead lines operating at or below 69 kV. These
insulators are used to support line conductors in suspension or deadend modes such as line terminations, angles,
and tangents. These insulators can be used with bare or covered conductors.
CORE MATERIAL
The core rod of the distribution deadend/suspension insulator is made of a high quality fiberglass that has been
specially formulated for electrical and mechanical applications.
TECHNICAL DATA
SPECIFICATIONS
UNIT
Voltage Class
CEA & ANSI Class
Section Length L
Dry Arcing Distance
Leakage Distance
Low-Frequency
Dry
Flashover
Wet
Impulse Critical Flashover
(Pos.)
Radio Influence Voltage Test
(RIV) at 1 MHz
Max.
Specified Mechanical Load
(SML)
Torsional Load
Approx. Weight
Standard Packaging
kV
mm (in)
mm (in)
mm (in)
kV
kV
KL15ASCTM
15
DS15
322 (12.7)
193 (7.6)
384 (15.1)
100
70
KL28ASCTM
28
DS28
433 (17.0)
290 (11.4)
590 (23.2)
135
105
CATALOGUE NUMBER**
KL35SCTM
KL46SCT
35
46
DS35
DS46
486 (19.1)
574 (22.6)
348 (13.7)
419 (16.5)
750 (29.5)
988 (38.9)
153
180
144
150
KL46SCTA
46
646 (25.4)
490 (19.3)
1059 (41.7)
200
155
KL69HC1T116
69
DS69
733 (28.9)
627 (24.7)
1798 (70.8)
260
205
kV
145
225
264
300
355
425
kV
V
15
Below 1
20
Below 1
30
Below 3
30
Below 3
30
Below 5
44
Below 2
kN (lb)
70 (15,700)
70 (15,700)
70 (15,700)
90 (20,200)
90 (20,200)
90 (20,200)
Nm (ftlb)
kg (lb)
-
83 (62)
0.7 (1.5)
15
83 (62)
0.8 (1.8)
15
83 (62)
1.1 (2.5)
12
83 (62)
1.4 (3.0)
12
83 (62)
1.6 (3.5)
12
83 (62)
2.2 (4.8)
3
** The catalogue numbers in the above table are for CT clevis-tongue fittings. For other combinations of end
fittings or mechanical strengths, see End Fittings Section.
END FITTINGS
There are five standard end fittings that are available on the deadend/suspension insulators: clevis, tongue,
thimble eye, socket, and ball (See Below). The clevis, tongue, and thimble eye fittings are made from high
strength, corrosion resistant extruded aluminum. While the socket and ball fittings are hot-dip galvanized iron.
The end fittings are crimped on to the core rod to provide the mechanical performance. A watertight seal
between the rubber and end fittings eliminates possible moisture ingress. This special silicone rubber to metal
fittings sealing process provides total exclusion of moisture.
The end fittings of the distribution class deadend/suspension are rated for a specified mechanical strength,
SML of 70 kN (15,700 lb) or 90 kN (20,200 lb).
The clevis and tongue end fittings are the two most common fittings used with additional adaptors and
clamps. The thimble eye end fitting is a unique design that integrates the insulator tongue end fitting and a
preformed conductor grip adapter to attach to the line conductor. This thimble eye essentially eliminates one
item in the assembly and from inventory.
For other special end fittings please contact K-Line Insulators.
Clevis - C
Tongue - T
Thimble Eye H
SML 90 kN
Socket S
Ball B
SML 90 kN
SML 90 kN
Catalogue D-LP
PERFORMANCE BENEFITS
The performance benefits of K-Line Insulators distribution line post insulators are listed below.
Improves Reliability (by minimizing interruptions and outages due to vandalism, pole fires, and
flashovers in all types of environments)
Eliminates or Reduces Maintenance (such as washing and trouble calls) and is compatible with existing
plant
Improves Power Quality (less RI and TVI)
Energy Efficiency (lower losses due to lower leakage currents)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)
APPLICATION
Distribution line post insulators are used on overhead distribution lines operating at and below 69 kV. These
insulators are commonly installed on metal or wooden structures to horizontally or vertically support the line
conductor. Also, these insulators are used to support high voltage conductor jumpers or leads.
ROD
The core rod of the insulator is made of a high quality fiberglass that has been specially formulated for electrical
and mechanical applications.
K-Clamp**
H-Horizontal
V-Vertical
T-TieTop (C-neck)
TF-TieTop (F-neck)
TECHNICAL DATA
SPECIFICATION
UNIT
Voltage Class
CEA Class
Section Length (L)***
Dry Arcing Distance
Leakage Distance
Critical Impulse Flashover (Positive)
Dry
Low-Frequency Flashover
Wet
Test
Radio Influence Voltage (RIV)
at 1000 kHz
Max
kV
mm (in)
mm (in)
mm (in)
kV
kV
kV
V
kN (lb)
kN (lb)
kN (lb)
kg (lb)
-
KL15S
15
LP15
297 (11.7)
138 (5.4)
275 (10.8)
129
75
40
10
2.5
22 (5000)
12.5 (2800)
6 (1350)
2
3.4 (7.4)
3
CATALOGUE NUMBER*
KL28S
KL35S
KL46S
28
348 (13.7)
184 (7.2)
420 (16.5)
156
92
62
15
2.5
22 (5000)
12.5 (2800)
6 (1350)
3
3.7 (8.0)
3
35
LP28M
424 (16.7)
264 (10.4)
657 (25.9)
193
118
83
22
2.5
22 (5000)
12.5 (2800)
6 (1350)
5
4.3 (9.4)
3
46
LP46
501 (19.7)
339 (13.3)
860 (33.9)
240
146
111
30
2.5
22 (5000)
12.5 (2800)
6 (1350)
6
4.7 (10.3)
3
KL69S
69
LP46M
640 (25.2)
478 (18.8)
1121 (44.1)
309
203
160
30
2.5
22 (5000)
12.5 (2800)
6 (1350)
10
9.1 (20.0)
2
Ordering Information
To catalogue number, add suffix H for horizontal, V for vertical, T for C-neck Tie-top, TF for the F-neck Tie-top, or K for
K-clamp. The standard base thread is -10 UNC. Different base threads are available upon request.
END FITTINGS
LINE END FITTING
The line end fitting of line post insulators are available in four different configurations: horizontal or vertical
clamp-top, tie-top, or K-clamp.
All line end fittings on line post insulators are made of corrosion resistant aluminum alloy castings.
Section Length
K-Clamp
Horizontal
Vertical
Tie-Top (F-neck)
Tie-Top (C-neck)
K
H
V
TF
T
Clamp-Top
The conventional horizontal and vertical trunnion accommodates a standard line post insulator, bolted conductor
clamp. On the horizontal design the line end fitting has an additional eye for the attachment of other devices
during installation or maintenance activities.
Tie-Top
The tie-top is designed for tying a conductor to the neck of the insulator. It is available in two standard neck
sizes: C or F-neck.
K-Clamp
K-Line Insulators Limited has introduced a new concept in the polymer line post live end fitting design. This end
fitting is referred to as the K clamp. The uniqueness of this end fitting is a result of the many advantages it has
over the traditional horizontal, vertical and tie-top configurations.
Some advantages of the K clamp include:
1) Excellent corrosion resistant aluminum casting
2) A long, smooth contoured conductor clamping zone
3) The clamp accommodates a full range of conductor sizes
4) A single captive live-line operable bolt
5) All parts are captive
6) Lower overall length permits standard cover up hoods to effectively cover all insulator sheds
7) The design can be installed in either a horizontal or vertical configuration
8) Inventory reduction is accomplished because one insulator is used for both configurations and a
separate clamp is not required
9) The price of the new insulator is cost comparative with the purchase of a standard trunnion post
insulator and a separate clamp
10) Substantial labour cost savings in stringing, sagging and conductor clamping
11) Other savings related to shipping, stocking and maintenance
Vertical
Tie-Top
Technical Data
SPECIFICATION
UNIT
CATALOGUE
NUMBER*
SPECIFICATION
UNIT
KL69S
Voltage Class
kV
CEA Class
ANSI Class
Dry Arcing Distance
Leakage Distance
Critical Impulse Flashover (Positive)
Low-Frequency Flashover
Dry
Wet
kV
45
Max
kN (lb)
22 (5000)
kN (lb)
11 (2475)
551 (21.7)
kN (lb)
5.5 (1240)
1511 (59.5)
Approx. Weight
kg (lb)
8.0 (17.5)
LP69M
kV
kV
KL69S
Test
69
mm
(in)
mm
(in)
CATALOGUE
NUMBER*
360
Standard Packaging
235
190**
* Ordering Information
To Line Post Catalogue Number, add suffix KP1 for K-clamp, HP1 for horizontal, VP1 for vertical, or TFP1 for tie-top. The standard base thread is -9 UNC.
Different base threads are available upon request.
** The value shown is as per CEA and the ANSI value is 165 kV.
July 2005
Catalogue D-SP
PERFORMANCE BENEFITS
The performance benefits of K-Line Insulators distribution station post insulators are listed below.
Improved Reliability (interruptions and outages due to vandalism, and flashovers in all types of
environments are a thing of the past)
Eliminates or Reduces Maintenance (such as washing and trouble calls) and are compatible with existing
porcelain insulators
Improves Power Quality (lower RI and TVI)
Energy Efficiency (reduced losses due to lower leakage currents)
Safety (light weight for handling and installation, eliminates catastrophic mechanical failures)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)
APPLICATION
Distribution station post insulators are used in open-type stations operating at and below 46 kV. These insulators
support the bus, leads, or other apparatus within the station.
ROD
The core rod of the distribution station post insulator is made of a high quality fiberglass that has been specially
formulated for electrical and mechanical applications.
TECHNICAL DATA
SPECIFICATION
Voltage Class
ANSI Technical Reference (TR)
UNIT
kV
KL15SCP
KL25SC
15
25
CATALOGUE NUMBER*
KL25SP
KL25SPN
28
28
KL35SP
KL46SPT2
35
46
No.
4 & 205
208
10
210
214
mm (in)
254 (10)
305 (12)
355 (14)
381 (15)
559 (22)
mm (in)
145 (5.7)
190 (7.5)
260 (10.2)
270 (10.6)
Leakage Distance
mm (in)
275 (10.8)
420 (16.5)
635 (25)
660 (26.0)
kV
125
155
165
185
457 (18)
345
(13.6)
864
(34.0)
225
kV
130
160
175
195
240
310
kV
40
55
65
75
100
140
kV
10
15
22
22
30
30
2.5
2.5
2.5
2.5
2.5
2.5
45
(10000)
12.5
(2800)
45
(10000)
12.5
(2800)
45
(10000)
12.5
(2800)
45
(10000)
12.5
(2800)
45
(10000)
12.5
(2800)
45
(10000)
kN (lb)
6 (1350)
6 (1350)
6 (1350)
6 (1350)
6 (1350)
6 (1350)
No.
10
kg (lb)
3.4 (7.4)
3.7 (8.0)
4.2 (9.2)
4.3 (9.4)
6.0 (13.4)
9.1 (20.0)
Impulse Withstand
Critical Positive Impulse
Flashover
Low-Frequency Wet Withstand
Radio Influence
Test
Voltage (RIV) at
Max
1000 kHz
Specified Tensile Load (STL)
Specified Cantilever Load
(SCL)
Max Design Cantilever Load
(MDCL)
Number of Sheds
Approx. Weight
kN (lb)
kN (lb)
483 (19.0)
1121 (44.1)
275
12.5 (2800)
* Ordering Information:
1. Above catalogue numbers apply to insulators with through holes on both ends. (Except for KL46SPT2).
2. Add T1 to catalogue numbers for insulators with one end tapped & the other with through holes.
3. Add T2 to catalogue number for insulators with both ends tapped.
END BASES
The standard base fittings are flat round iron bases that are available with bolt circle mounting holes with
either through or tapped holes. These bases are compatible with the porcelain station post insulator
standard.
The end bases are radially swaged on to the core rod to provide the mechanical performance and reduce
the stress concentration. Our proprietary design ensures a watertight seal between the rubber and end
fitting. This special silicone rubber to metal fittings sealing process prevents moisture ingress to the core
fiberglass rod. For other special base requirements, please contact K-Line Insulators Limited.
Corrosion protection of the end bases is provided by hot-dip galvanizing to CSA G164 and ASTM A153
specifications.
March 2003
Catalogue T-DS
PERFORMANCE BENEFITS
The performance benefits of K-Line Insulators transmission suspension/deadend insulators are listed below.
Improved Reliability (interruptions and outages due to vandalism, pole fires, and flashovers in all types of
environments are a thing of the past)
Eliminates or Reduces Maintenance (such as washing and trouble calls) and is compatible with existing plant
Improves Power Quality (less RI and TVI)
Energy Efficiency (reduced losses due to lower leakage currents)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)
APPLICATION
Transmission suspension/deadend insulators are used on transmission lines operating at and above 66kV. These
insulators are installed on metal or wooden structures on cross arms to hold the conductor longitudinally (dead-end) or
vertically (suspension). The connections to the structures or arms and line vary depending on the Utilities preference.
ROD
The core rod of the transmission suspension/deadend insulator is made of a high quality fiberglass that has been
specially formulated for electrical and mechanical applications.
TECHNICAL DATA
TECHNICAL DATA
Catalogue
Number
Voltage
Class
kV
KL69HBS13
Section
Length (Note 1)
L
mm
(in)
Dry Arcing
Distance
mm
(in)
Leakage
Distance
mm
Positive
Critical
Impulse
Flashover
(in)
Low
Frequency
Flashover
Weight
(Note 2)
kV
Dry
kV
Wet
kV
kg
(lb)
660 (26.0)
523 (20.6)
1466 (57.7)
355
215
170
2.9 (6.3)
764 (30.1)
627 (24.7)
1798 (70.8)
425
260
205
3.3 (7.2)
KL69HBS19
867 (34.1)
732 (28.8)
2131 (83.9)
485
300
235
3.6 (8.0)
KL115HBS22
970 (38.2)
818 (32.2)
2461 (96.9)
540
335
265
4.2 (9.2)
1074 (42.3)
917 (36.1)
2794 (110.0)
600
375
300
4.5 (10.0)
KL115HBS28
1179 (46.4)
1021 (40.2)
3127 (123.1)
660
415
335
5.0 (10.9)
KL138HBS31
1281 (50.4)
1128 (44.4)
3460 (136.2)
725
455
370
5.4 (11.8)
1384 (54.5)
1229 (48.4)
3792 (149.3)
785
495
400
5.8 (12.7)
KL138HBS37
1488 (58.6)
1331 (52.4)
4125 (162.4)
845
530
430
6.1 (13.1)
KL161HBS40
1590 (62.6)
1410 (55.5)
4458 (175.5)
895
560
460
7.5 (16.4)
1694 (66.7)
1514 (59.6)
4790 (188.6)
960
605
495
7.9 (17.3)
KL161HBS46
1798 (70.8)
1618 (63.7)
5123 (201.7)
1025
650
530
8.3 (18.2)
KL230HBS49
1903 (74.9)
1722 (67.8)
5456 (214.8)
1090
695
570
8.6 (19.0)
KL69HBS16
KL115HBS25
KL138HBS34
KL161HBS43
KL230HBS52
KL230HBS55
69
115
138
161
230
2004 (78.9)
1824 (71.8)
5789 (227.9)
1155
740
605
9.0 (19.9)
2108 (83.0)
1928 (75.9)
6121 (241.0)
1220
785
640
9.5
(20.8)
Notes:
1.
Section lengths are based on ball and socket hardware. For lengths of insulators with alternate end fittings combination see
Section Lengths.
2.
Weight includes standard rings where applicable. See section on Corona Rings.
SECTION LENGTHS
The section lengths (L) published on the Technical Data sheet are for the ball and socket end fittings. For alternate
combinations of end fittings, use the following table to establish section lengths.
End Fitting
Designation
BS
BY
BE
EE
CT
Section Length
L (see Technical Data sheet)
L + 36 mm (1.4)
L + 41 mm (1.6)
L + 84 mm (3.3)
L + 21 mm (0.8)
CORONA RINGS
High voltage lines above 88 kV phase-to-phase can generate unnecessary noise (RI and TVI) and corona due to
the high electrical stress concentration. To minimize these effects gradient or corona rings are installed on the end
fitting of the insulator. Guidelines used in the application of these rings are noted below.
Insulators that are used on system voltages above 88 kV and below 150 kV are supplied with a built-in gradient
ring. Insulators that are used on system voltages from 150 kV and above are supplied with a separate corona ring
for assembly in the field before installation. The ring is designed for installation in only one orientation and
location to avoid miss application. These rings are made from aluminum that make them light weight and
corrosion resistant.
Corona Ring
150 kV to 230 kV
END FITTINGS
The end fittings on the transmission insulator are made of high strength, cast (forged) steel. The insulators have a
specified mechanical load (SML) rating of 120 kN (27,000 lbs.). Also, all insulators are proof tested to 60 kN
(13,500 lbs.) in tension.
The end fittings are radialy swaged on to the core rod to provide the mechanical performance and reduce the
stress concentration. Our proprietary design insures a watertight seal between the rubber and end fitting. This
special silicone rubber to metal fittings sealing process prevents moisture ingress to the core fiberglass rod.
Hot-dip galvanizing to CSA G164 and ASTM A153 Standard provides corrosion protection of the end fittings.
The cotter key is made from stainless steel.
The standard end fittings that are available are listed and detailed in the below. For other special end fittings
contact K-Line Insulator Limited.
ORDERING INFORMATION
For ordering the catalogue number of the specific insulator is formulated as shown below.
March 2003
Catalogue T-LP
PERFORMANCE BENEFITS
The performance benefits of K-Line Insulators transmission line post insulators are listed below.
Improved Reliability (interruptions and outages due to vandalism, pole fires, and flashovers in all types of
environments are a thing of the past)
Eliminate or Reduce Maintenance (such as washing and less trouble calls) and is compatible with existing
plant
Improves Power Quality (lower RI and TVI)
Energy Efficiency (reduced losses due to lower leakage currents)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)
APPLICATION
Transmission line post insulators are used on overhead transmission lines operating at and above 66 kV. These
insulators are commonly installed either vertically or horizontally on metal or wooden structures to support the
conductor. Also, these insulators are used to support high voltage conductor jumpers or leads.
ROD
The core rod of the transmission line post insulator is made of a high quality fiberglass that has been specially
formulated for electrical and mechanical applications.
TECHNICAL DATA
Catalog
Number
Voltage
Class
kV
KL69ASH13
KL69ASH16
69
KL69ASH19
KL115ASH22
Section
Length
(See Note)
L
mm
(in)
Dry Arcing
Distance
mm
(in)
Leakage
Distance
mm
(in)
Positive
Critical
Impulse
Flashover
kV
Low
Frequency
Flashover
Dry
kV
Wet
kV
Ultimate
Cantilever Load
kN
(lbs)
775 (30.5)
617
(24.3)
1544 (60.8)
380
250
225
29.4 (6600)
899 (35.4)
742
(29.2)
1890 (74.4)
450
295
260
26.1 (5870)
1022 (40.3)
866
(34.1)
2238 (88.1)
520
340
295
22.9 (5140)
1147 (45.2)
991
(39.0)
2583 (101.7)
595
385
330
19.6 (4410)
1271 (50.0)
1115 (43.9)
2931 (115.4)
665
430
365
16.5 (3700)
1395 (54.9)
1237 (48.7)
3277 (129.0)
735
475
410
14.9 (3340)
1519 (59.8)
1361 (53.6)
3622 (142.6)
805
520
450
13.3 (2980)
1643 (64.7)
1486 (58.5)
3970 (156.3)
880
560
475
11.7 (2630)
1767 (69.9)
1610 (63.4)
4318 (170.0)
955
600
495
10.1 (2275)
115
KL115ASH25
KL138ASH28
138
KL138ASH31
KL161ASH34
161
KL161ASH37
Note: Section length based on a horizontal trunnion and without any support base. For alternate bases and
line fittings (as well as overall lengths and weights of these) refer to the section on fittings and weights.
END BASES
The standard base fittings are flat round iron bases that are available with bolt circle mounting holes with
either through or tapped holes. These bases are compatible with the porcelain station post insulator
standard.
The end bases are radially swaged on to the core rod to provide the mechanical performance and reduce
the stress concentration. Our proprietary design insures a watertight seal between the rubber and end
fitting. This special silicone rubber to metal fittings sealing process prevents moisture ingress to the core
fiberglass rod. For other special base requirements, please contact K-Line Insulators Limited.
Corrosion protection of the end bases is provided by hot-dip galvanizing to CSA G164 or ASTM A153
specifications.
March 2003
Catalogue T-SP
PERFORMANCE BENEFITS
The performance benefits of K-Line Insulators transmission station post insulators are listed below.
Improved Reliability (interruptions and outages due to vandalism, and flashovers in all types of
environments are a thing of the past)
Eliminate or Reduce Maintenance (such as washing and trouble calls) and is compatible with existing
porcelain insulators
Improves Power Quality (lower RI and TVI)
Energy Efficiency (reduced losses due to lower leakage currents)
Safety (light weight for handling and installation, eliminates catastrophic mechanical failures)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)
APPLICATION
Transmission station post insulators are used in open-type stations operating at and above 66 kV. These insulators
support the bus, leads, or other apparatus within the station.
ROD
The core rod of the transmission station post insulator is made of a high quality fiberglass that has been specially
formulated for electrical and mechanical applications.
TECHNICAL DATA
Catalogue
Voltage Section
Number
(See Notes 1, Class Length, L
2, & 3)
kV
mm (in)
KL69ASP13
KL69ASP16
69
KL69ASP19
KL115ASP22
KL115ASP25
KL138ASP28
KL138ASP31
KL161ASP34
KL161ASP37
115
138
161
Dry
Arcing
Distance
Leakage
Distance
mm
mm
(in)
(in)
Positive
Impulse
Withstand
kV
Low
Frequency
Flashover
Dry
Wet
Specified
Cantilever
Load
SCL
Specified
Tensile
Load
STL
kV
kN
kN
kV
(lbs)
(lbs)
Equivalent
Height to
ANSI
Technical
Reference
Number
762 (30.0)
605 (23.8)
1534 (60.4)
355
245
195
29.9 (6725)
111 (25,000)
TR216/278
895 (35.2)
742 (29.2)
1890 (74.4)
430
295
240
26.2 (5885)
111 (25,000)
2238 (88.1)
520
340
280
22.9 (5140)
111 (25,000)
2583 (101.7)
565
385
320
19.7 (4440)
111 (25,000)
TR286/287
635
430
360
16.5 (3705)
111 (25,000)
690
470
400
15.1 (3405)
111 (25,000)
TR288/289
765
520
450
13.3 (2995)
111 (25,000)
830
555
480
11.7 (2640)
111 (25,000)
900
595
510
10.2 (2290)
111 (25,000)
Ordering Information:
1. Above catalogue numbers apply to insulators with through holes on both ends.
2. Add T1 to catalogue numbers for insulators with one end tapped & the other with through holes.
3. Add T2 to catalogue number for insulators with both ends tapped.
End Bases
The standard base fittings are flat round iron bases that are available with bolt circle mounting holes with
either through or tapped holes. These bases are compatible with the porcelain station post insulator
standard.
The end bases are radialy swaged on to the core rod to provide the mechanical performance and reduce
the stress concentration. Our proprietary design insures a watertight seal between the rubber and end
fitting. This special silicone rubber to metal fittings sealing process prevents moisture ingress to the core
fiberglass rod. For other special base requirements, please contact K-Line Insulators Limited.
Corrosion protection of the end bases is provided by hot-dip galvanizing to CSA G164 and ASTM A153
specifications.
Catalogue GI
TECHNICAL DATA
SPECIFICATIONS
KL11
KL24
KL36
KL54
KL78
GI30
GI60
GI90
GI140
GI200
mm (in)
280 (11)
610 (24)
910 (36)
1370 (54)
1980 (78)
Dry
kV
115
235
335
485
680
Wet
kV
60
145
235
370
550
kN (lb)
100 (22,480)
100 (22,480)
100 (22,480)
100 (22,480)
100 (22,480)
CEA Class
Insulated Length A * *
Low-Frequency Flashover
Specified Mechanical Load
(SML)
Routine Test Load (RTL)
CATALOGUE NUMBER *
UNIT
kN (lb)
50 (11,240)
50 (11,240)
50 (11,240)
50 (11,240)
50 (11,240)
Torsional Load
Nm (ftlb)
56 (42)
56 (42)
56 (42)
56 (42)
56 (42)
Approx. Weight
kg (lb)
0.6 (1.3)
0.7 (1.5)
0.9 (2.0)
1.5 (3.3)
2.0 (4.4)
24
15
15
15
15
Standard Packaging
Ordering Information:
*
To catalogue number, add suffix CTS for clevis-tongue, CCS for clevis-clevis, RRS for roller-roller, or HHS for thimble eye-thimble eye, (other
custom fittings can be accommodated).
** Other lengths are available on request.
Catalogue D-EI
APPLICATION
Extension insulators are used when more length is needed than the standard insulator can supply.
ROD
The core rod of the extension insulator is made of a high quality fiberglass that has been specially formulated for
electrical and mechanical applications.
FITTINGS
The extension insulator comes standard with aluminum clevis and tongue end fittings, and a coupler.
TECHNICAL DATA
CATALOG
NUMBER
VOLTAGE
RATING (kV)
(See Notes 1 & 2)
DIMENSIONS
mm
WEIGHT
kg (lbs.)
749 (29.5)
279 (11.0)
1.2 (2.6)
1080 (42.5)
610 (24.0)
1.4 (3.1)
KL15ASX36S
1384 (54.5)
914 (36.0)
1.6 (3.5)
KL28ASX11
864 (34.0)
279 (11.0)
1.4 (3.1)
1196 (47.1)
610 (24.0)
1.6 (3.6)
1499 (59.0)
914 (36.0)
1.9 (4.1)
KL15ASX11S
KL15ASX24S
KL28ASX24
15
28
KL28ASX36
KL35SX11
KL35SX24
35
KL35SX36
KL46SX11
KL46SX24
46
KL46SX36
889 (35.0)
279 (11.0)
2.2 (4.9)
1219 (48.0)
610 (24.0)
2.5 (5.4)
1524 (60.0)
914 (36.0)
2.6 (5.8)
1003 (39.5)
279 (11.0)
1.7 (3.8)
1334 (52.5)
610 (24.0)
2.0 (4.3)
1638 (64.5)
914 (36.0)
2.1 (4.6)
Notes:
1) For the complete specifications of the insulator, refer to Distribution Insulators Deadend/Suspension, Catalogue D-DS.
2) The silicone covered rod in series with the insulator will add to the total insulation level.
March 2003
Catalogue TD-IPS
PERFORMANCE BENEFITS
The performance benefits of K-Line Insulators interphase spacer insulators are listed below.
Improves Reliability (by minimizes interruptions and outages due to vandalism and flashovers in all types of
environments)
Eliminates or Reduces Maintenance (such as washing and trouble calls) and is compatible with existing plant
Improves Power Quality (less RI and TVI)
Energy Efficiency (lower losses due to lower leakage currents)
Safety (light weight for handling and installation)
Service Life (consistent performance over its service life)
Life Cycle Cost (savings over porcelain insulators)
APPLICATION
One or two interphase spacers are installed in each span. One spacer is installed if there are two vertically
positioned conductors and it is installed at one-third of the span. Two spacers are installed if there are three
vertically positioned conductors. The first spacer is installed between the mid and lower conductors one-third of
the span from one end. The second spacer is installed between the mid and upper conductor one-quarter of the
span from the other end.
CORE MATERIAL
The core rod of the interphase spacer insulator is made of a high quality fiberglass that has been specially
formulated for electrical and mechanical applications.
TECHNICAL DATA
SPECIFICATIONS
UNIT
Voltage Class
Section Length L
Dry Arcing Distance
Leakage Distance
kV
mm (in)
mm (in)
mm (in)
Low-Frequency Flashover
Dry
Wet
Test
Max.
kV
kV
kV
kV
V
kN (lb)
kN (lb)
kg (lb)
-
CATALOGUE NUMBER**
KL15ARSIU
15
389 (15.3)
195 (7.6)
385 (15.1)
100
70
145
15
Below 1
1.6 (362)
0.8 (181)
0.7 (1.5)
15
KL28ARSIU
KL35SRSIU
KL46SRSIU
KL69HRSIU16
28
(19.7)
(11.4)
(23.2)
135
105
225
20
Below 1
1.1 (250)
0.6 (125)
0.9 (1.9)
15
35
569 (22.4)
348 (13.7)
750 (29.5)
153
144
264
30
Below 3
0.9 (211)
0.5 (106)
2.1 (4.7)
12
46
619 (24.4)
419 (16.5)
988 (38.9)
180
150
300
30
Below 5
0.8 (190)
0.4 (95)
2.2 (4.8)
12
69
779 (30.7)
627 (24.7)
1798 (70.8)
260
205
425
44
Below 10
0.6 (144)
0.3 (72)
2.3 (5.1)
3
500
290
590
** Options: For 5/8 tapped hole add X, for M16 add M16, or for M20 add M20 and for tin-plated clamp add D to the catalogue number.
APPLICATION
Distribution riser support insulators are used on distribution lines operating at or below 69 kV. These insulators are
installed on metal, concrete or wooden structures and on cross arms to hold and insulate the conductor leads.
ROD
The core rod of the distribution riser support insulator is made of a high quality fiberglass that has been specially
formulated for electrical and mechanical applications.
FITTINGS
The riser insulator comes standard with a clamp to hold the conductor and a threaded hole for mounting.
Conductor Clamp
The clamp is an aluminum clamp that can accommodate copper or aluminum conductors # 6 AWG (0.20) to 556.5
kcmil (0.95).
Threaded Base
The base is typically threaded for -11, -10, M16x2, or M20x2.5 galvanized bolt.
For other special clamp features or base threads please contact K-Line Insulators Limited.
Catalogue MB-PT
Single Circuit
Pole Top Framing Assembly
Single Circuit
Pole Top Framing Assembly
The ultimate in labour saving and convenience is provided by K-Line's single circuit pole-top framing
assembly (35 kV shown). The assembly comes complete in kit form with mounting bracket, polymer line post
insulators, trunnion clamps and insulator mounting studs. Install with two bolts and the structure is ready to
sag.
The hot dip galvanized steel bracket comes with predrilled holes for mounting of riser support insulators and a
grounding lug. The insulators are of silicone, the ultimate in polymer line post insulators for maintenance-free
operation.
.