Académique Documents
Professionnel Documents
Culture Documents
Category 2
DATE OF
ISSUE
TEXT AFFECTED
SIGNATURE &
DATE
Revision Note
This Issue of this Standard has been prepared to incorporate changes to text and presentation.
The technical content has been amended.
Historical Record
NES 524 Part 1 Issue 1
NES 524 Part 1 Issue 2
NES 524 Part 1 Issue 3
Def Stan 02-514 Part 1 Issue 1
Nov 1991
Apr 2000
PART 1 ISSUE 2
Published by:
Defence Procurement Agency,
An Executive Agency of The Ministry of Defence,
UK Defence Standardization,
Kentigern House,
65 Brown Street,
Glasgow, G2 8EX.
1
SCOPE
1.
All cables fitted outside the hulls of Submarines are to be sheathed with medium density
polyethylene and are to be passed through the pressure hull by suitable moulded polyethylene
glands. Cables with Polychloroprene (PCP) or Chlorosulphonated Polyethylene (CSP) sheaths
are not to be used except when approved by the Ship Support Agency/
Marine Electrical Systems 2 (SSA/MLS2).
2.
The earliest versions of polyethylene hull glands were the screw type fitted to SSK and early
SSN and the flange type fitted to early SSBN. A later development resulted in the introduction
of the spigot (castellated nut) type hull glands which are fitted to Swiftsure, Trafalgar and
Vanguard Classes of Submarines.
3.
All types of moulded polyethylene spigot type hull glands have been included in this Defence
Standard. Also included are multistem glands used on existing sonar systems, but these are
not to be considered for any new service requirement.
4.
Two standards of pressure hull spigot are in current use: Imperial (23/8 in dia, 60.32 mm dia)
for Swiftsure and Trafalgar Classes, and Metric (62.95 mm dia) for Vanguard Class. Glands
in the preferred metric range of Section 4.4 can be supplied with either interface. When
ordering, it is necessary to quote the Service Drawing Number (SDN) for the basic
configuration and the interface type (imperial or metric), and the lengths of outboard and
inboard cable required.
FOREWORD
Sponsorship
1.
This Defence Standard is sponsored by the Defence Logistics Organisation (DLO), Ministry
of Defence (MOD).
2.
Part 2:
Part 3:
3.
Any user of this Def Stan either within MOD or in industry may propose an amendment to it.
Proposals for amendments that are not directly applicable to a particular contract are to be
made to the publishing authority identified on Page (i), and those directly applicable to a
particular contract are to be dealt with using existing departmental procedures.
4.
5.
6.
Unless otherwise stated, reference in this standard to approval, approved, authorized and
similar terms means by the MOD in writing.
7.
Any significant amendments that may be made to this standard at a later date will be indicated
by a vertical sideline. Deletions will be indicated by 000 appearing at the end of the line
interval.
8.
Conditions of Release
General
9.
This Def Stan has been devised solely for the use of the MOD, and its contractors in the
execution of contracts for the MOD. To the extent permitted by law, the MOD hereby excludes
all liability whatsoever and howsoever arising (including but without limitation, liability
resulting from negligence) for any loss or damage however caused when the standard is used
for any other purpose.
10.
This document is Crown Copyright and the information herein may be subject to Crown or
third party rights. It is not to be released, reproduced or published without written permission
of the MOD.
11.
The Crown reserves the right to amend or modify the contents of this standard without
consulting or informing any holder.
This Def Stan is the property of the Crown. Unless otherwise authorized in writing by the
MOD it must be returned on completion of the contract, or submission of the tender, in
connection with which it is issued.
13.
When this standard is used in connection with a MOD tender or contract, the user is to ensure
that he is in possession of the appropriate version of each document, including related
documents, relevant to each particular tender or contract. Enquiries in this connection may
be made to the authority named in the tender or contract.
14.
When standard are incorporated into MOD contracts, users are responsible for their correct
application and for complying with contractual and any other statutory requirements.
Compliance with an Def Stan does not of itself confer immunity from legal obligations.
The Category of this Naval Defence has been determined using the following criteria:
a.
b.
c.
Related Documents
16.
In the tender and procurement processes the related documents listed in each section and
Annex A can be obtained as follows:
a.
British Standards
b.
c.
Other documents
17.
All applications to Ministry Establishments for related documents are to quote the relevant
MOD Invitation to Tender or Contract number and date, together with the sponsoring
Directorate and the Tender or Contract Sponsor.
18.
Prime Contractors are responsible for supplying their subcontractors with relevant
documentation, including specifications, standards and drawings.
This Defence Standard may call for the use of processes, substances and/or procedures that
may be injurious to health if adequate precautions are not taken. It refers only to technical
suitability and in no way absolves either the supplier or the user from statutory obligations
relating to health and safety at any stage of manufacture or use. Where attention is drawn to
hazards, those quoted may not necessarily be exhaustive.
20.
This Def Stan has been written, and is to be used, taking into account the policy stipulated in
JSP430 MOD Ship Safety Management System Handbook.
Additional Information
(There is no relevant information included)
CONTENTS
Page No
TITLE PAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Sponsorship
............................................................... 3
Conditions of Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Categories of NES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Health and Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Additional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION
1.
PERFORMANCE SPECIFICATION . . . . . . . . . . . . . . . . . . . 8
SECTION
2.
NATIONAL/INTERNATIONAL REGULATIONS . . . . . . . . 8
SECTION
3.
MILITARY STANDARDS/REQUIREMENTS . . . . . . . . . . . . 8
SECTION
4.
4.1
Figure 4.1
DESIGN REQUIREMENTS/GUIDANCE . . . . . . . . . . . . . . . 8
Imperial Spigot Type (Castellated) Hull Glands . . . . . . . . . . . 8
Gland and Cable Assembly Spigot Type, 1 Screened Quad,
(Type F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Gland and Cable Assembly Spigot Type, 4 Way, (Type G) . . 10
Gland and Cable Assembly Spigot Type, 6 Screened Pairs,
(Type B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Gland and Cable Assembly Spigot Type, 8 Pair, (Type A) . . 12
Gland and Cable Assembly Spigot Type, 4 Coaxial 75 Ohms,
(Type C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Gland and Cable Assembly Spigot Type, 4 Coaxial 50 Ohms,
(Type C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Gland and Cable Assembly, Spigot Type, 4 Coaxial
50 Ohms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Gland and Cable Assembly, Spigot Type,
1 Screened Pair + 1 x 3 Core (Type H) . . . . . . . . . . . . . . . . . . 16
Gland and Cable Assembly, Spigot Type, 19 Screened Pair . 17
Gland and Cable Assembly, Spigot Type, 19 Screened Pair . 18
Figure 4.2
Figure 4.3
Figure 4.4
Figure 4.5
Figure 4.6
Figure 4.7
Figure 4.8
Figure 4.9
Figure 4.10
Page No
Figure 4.11
Figure 4.12
4.2
Figure 4.13
Figure 4.14
Figure 4.15
4.3
Figure 4.16
Figure 4.17
Figure 4.18
Figure 4.19
Figure 4.20
Figure 4.21
Figure 4.22
Figure 4.23
4.4
Figure 4.24
Figure 4.25
Figure 4.26
Figure 4.27
Figure 4.28
Figure 4.29
Figure 4.30
Figure 4.31
Figure 4.32
Figure 4.33
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Page No
SECTION
5.
ANNEX
A.
RELATED DOCUMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
ANNEX
B.
ANNEX
C.
1.
PERFORMANCE SPECIFICATION
This standard contains no Performance Specification information.
2.
NATIONAL/INTERNATIONAL REGULATIONS
This standard contains no National/International Regulations information.
3.
MILITARY STANDARDS/REQUIREMENTS
This standard contains no Military Standards/Requirements information.
4.
DESIGN REQUIREMENTS/GUIDANCE
4.1
Hull glands in this section are designed to be fitted to Swiftsure and Trafalgar
classes of Submarine only. They may be installed singularly in a single pressure
hull insert or grouped within a five way pressure hull insert.
Dimensions in Inches
Not to Scale
Cables HP Side
NSN 6145995227877
Type Screened Quad
Conductor CSA 0.5 mm2
Volts
600
Amps
2
No. of Cables
1
9.75
3.125
3.916
UNS 1A Thread
0.875
3.798
`O' Seal
5330999237760
Cables LP Side
NSN 6145995227877
Type Screened Quad
Conductor CSA 0.5 mm2
Volts
600
Amps
2
No. of Cables
1
2.377
FIGURE 4.1 Gland and Cable Assembly Spigot Type, 1 Screened Quad, (Type F)
9
Dimensions in Inches
Not to Scale
9.75
Cables HP Side
NSN 6145997248833
Type Single Core
Conductor CSA 6 mm2
Volts
600
Amps
19.5
No. of Cables
4
3.125
3.916
UNS 1A Thread
0.875
3.798
Cables LP Side
NSN 6145995252037
Type Single Core
Conductor CSA 6 mm2
Volts
600
Amps
19.5
No. of Cables
4
`O' Seal
5330999237760
2.377
FIGURE 4.2 Gland and Cable Assembly Spigot Type, 4 Way, (Type G)
10
Dimensions in Inches
Not to Scale
9.75
Cables HP Side
NSN 6145995434475
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
6
3.125
3.916
UNS 1A Thread
0.875
3.798
Cables LP Side
NSN 6145997248840
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
6
`O' Seal
5330999237760
2.377
FIGURE 4.3 Gland and Cable Assembly Spigot Type, 6 Screened Pairs, (Type B)
11
Dimensions in Inches
Not to Scale
9.75
Cables HP Side
NSN 6145997248831
Type Twisted Pair
Conductor CSA 1.5 mm2
Volts
600
Amps
4
No. of Cables
8
3.125
3.916
UNS 1A Thread
0.875
3.798
Cables LP Side
NSN 6145997248840
Type Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
8
`O' Seal
5330999237760
2.377
FIGURE 4.4 Gland and Cable Assembly Spigot Type, 8 Pair, (Type A)
12
Dimensions in Inches
Not to Scale
9.75
Cables HP Side
NSN 6145995278993
Type Coaxial 75 Ohms
Conductor CSA Volts
Amps
No. of Cables
4
3.125
3.916
UNS 1A Thread
0.875
3.798
Cables LP Side
NSN 6145995278993
Type Coaxial 75 Ohms
Conductor CSA Volts
Amps
No. of Cables
4
`O' Seal
5330999237760
2.377
FIGURE 4.5 Gland and Cable Assembly Spigot Type, 4 Coaxial 75 Ohms, (Type C)
13
Dimensions in Inches
Not to Scale
Cables HP Side
NSN 6145995278994
Type Coaxial 50 Ohms
Conductor CSA Volts
Amps
No. of Cables
4
9.75
3.125
3.916
UNS 1A Thread
0.875
3.798
Cables LP Side
NSN 6145995278994
Type Coaxial 50 Ohms
Conductor CSA Volts
Amps
No. of Cables
4
`O' Seal
5330999237760
2.377
FIGURE 4.6 Gland and Cable Assembly Spigot Type, 4 Coaxial 50 Ohms, (Type C)
NOTE Not to be used for new installations
14
Dimensions in Inches
Not to Scale
Cables HP Side
NSN 6145997248822
Type 50 Ohm Coaxial
Conductor CSA Volts
Amps
No. of Cables
4
9.75
3.125
3.916
UNS 1A Thread
0.875
3.798
Cables LP Side
NSN 6145997248834
Type 50 Ohm Coaxial
Conductor CSA Volts
Amps
No. of Cables
4
`O' Seal
5330999237760
2.377
FIGURE 4.7 Gland and Cable Assembly, Spigot Type, 4 Coaxial 50 Ohms
15
Dimensions in Inches
Not to Scale
Cables HP Side
NSN 6145995255127
Type 3 Core
Conductor CSA 4.5 mm2
Volts
440
Amps
26
No. of Cables
1
Cables LP Side
NSN 6145995255127
Type 3 Core
Conductor CSA 4.5 mm2
Volts
440
Amps
26
No. of Cables
1
NSN 6145997248840
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
1
3.125
3.916
UNS 1A Thread
3.798
0.875
9.75
NSN 6145995434475
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
1
`O' Seal
5330999237760
2.377
FIGURE 4.8 Gland and Cable Assembly, Spigot Type, 1 Screened Pair + 1 x 3 Core (Type
H)
16
Dimensions in Inches
Not to Scale
Cables HP Side
NSN 6145995434475
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
19
9.75
3.125
3.916
UNS 1A Thread
3.798
0.875
Cables LP Side
NSN 6145997248842
Type 19 Optomised
Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
1
`O' Seal
5330999237760
2.377
FIGURE 4.9 Gland and Cable Assembly, Spigot Type, 19 Screened Pair
17
Dimensions in Inches
Not to Scale
Cables HP Side
NSN 6145995434475
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
19
9.75
3.125
3.916
UNS 1A Thread
3.798
0.875
Cables LP Side
NSN 6145997248836
Type 19 Super Screened
Twisted Pair
Conductor CSA 0.4 mm2
Volts
600
Amps
1.5
No. of Cables
1
`O' Seal
5330999237760
2.377
FIGURE 4.10 Gland and Cable Assembly, Spigot Type, 19 Screened Pair
18
Dimensions in mm
Not to Scale
246
Cables HP Side
NSN 6145997248824
Type 3 Core Screened
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
19
79
8 TPI UNS
96.3
Cables LP Side
NSN 6145997248837
Type 3 Core Screened
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
19
`O' Seal
329
60.32
FIGURE 4.11 Gland and Cable Assembly, Spigot Type, 19 x 3 Core Screened
19
Dimensions in mm
Not to Scale
Cables HP Side
NSN 6145995434475
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
19
246
79
8 TPI UNS
22
96.3
Cables LP Side
NSN 6145997248840
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
19
`O' Seal
329
60.32
FIGURE 4.12 Gland and Cable Assembly, Spigot Type, 19 Screened Pair
20
4.2
Multi-Stem Glands
a.
21
14.125
Dimensions in Inches
Not to Scale
18.375
1.0
8.0
8 Holes 0.812 Dia
Equispaced on
6.5 PCD
7.125
2.996
Cables LP Side
NSN 6145995227892
Type 30 Quads (Each Quad
Individually Screened)
Conductor CSA 0.5 mm2
Volts
250
Amps
1.73
No. of Cables
1
Cables HP Side
NSN 6145995227875
Type Twisted Pair
Conductor CSA 1.3 mm2
Volts
600
Amps
4
No. of Cables
30
22
Dimensions in Inches
Not to Scale
11.3125
4.875
17.75
1.0
8.0
7.125
2.996
Cables LP Side
NSN 6145995227892
Type 30 Quads (Each Quad
Individually Screened)
Conductor CSA 0.5 mm2
Volts
250
Amps
1.73
No. of Cables
1
Cables HP Side
NSN 6145995227875
Type Twisted Pair
Conductor CSA 1.3 mm2
Volts
600
Amps
4
No. of Cables
60
Dimensions in Inches
Not to Scale
15.625
4.875
17.75
1.375
15
5.69
`O' Seal
5330999237764
2.996
Cables LP Side
NSN 6145995227892
Type 30 Quads (Each Quad
Individually Screened)
Conductor CSA 0.5 mm2
Volts
600
Amps
1.73
No. of Cables
1
Cables HP Side
NSN 6145995227875
Type Twisted Pair
Conductor CSA 1.3 mm2
Volts
600
Amps
4
No. of Cables
60
4.3
The glands illustrated in this section are special service glands and are not to be
adopted for any new service except when approved by SSA/MLS2.
25
Dimensions in Inches
Not to Scale
3.125
3.0
9.75
4.75
1.5
1.0
1.0
3.916
UNS 1A Thread
3.798
0.656 0.875
`O' Seal
5330999237760
2.377
Dimensions in Inches
Not to Scale
9.75
Cables HP Side
NSN
Type Single Core XLP Sheath
Conductor CSA 0.4 Inches2
Volts
440
Amps
400
No. of Cables
1
3.125
3.916
0.875
UNS 1A Thread
`O' Seal
5330999237760
2.377
7.0
Conductor Pin
Dimensions in Inches
Not to Scale
Cables HP Side
NSN Type 19 Quad
Conductor CSA
Volts
Amps
No. of Cables
0.3 mm2
115
0.3
1
9.75
3.125
3.916
UNS 1A Thread
Cables LP Side
NSN Type 19 Quad
Conductor CSA
Volts
Amps
No. of Cables
0.875
3.798
`O' Seal
5330999237760
0.3 mm2
115
0.3
1
2.377
Dimensions in Inches
Not to Scale
Cables HP Side
NSN Type 45 Quad (To Spec AH M271)
Conductor CSA 0.3 mm2
Volts
115
Amps
0.3
No. of Cables
1
11
3.125
3.196
UNS 1A Thread
0.875
3.798
Cables LP Side
NSN Type 45 Quad (Spec AHM271)
Conductor CSA 0.3 mm2
Volts
115
Amps
0.3
No. of Cables
1
`O' Seal
5330999237760
2.377
Dimensions in Inches
Not to Scale
Cables HP Side
NSN 6145995271312
Type 6 Core
Conductor CSA 0.5 mm2
Volts
600
Amps
3
No. of Cables
4
9.75
3.196
UNS 1A Thread
3.798
0.875
Cables LP Side
NSN 6145991116772
Type 6 Core PVC Sheath
DEF STAN 6112 Pt 5
Conductor CSA 0.5 mm2
Volts
440
Amps
3
No. of Cables
4
`O' Seal
5330999237760
2.377
Dimensions in mm
Not to Scale
160
Cables HP Side
NSN 6145995216965
Type 14 Core Heavy Duty
CSP Sheath
Conductor CSA 35 mm2
Volts
440
Amps
70
No. of Cables
1
`O' Seal
116
Cables LP Side
NSN 6145995216866
Type 14 Core Heavy Duty
CSP Sheath
Conductor CSA 35 mm2
Volts
440
Amps
83
No. of Cables
1
Service Degaussing `M' Coils
Figure Reproduced From Drawing No. SDN 007 038 075
Dimensions in Inches
Not to Scale
20.5
13.25
20
12
Dimensions in Inches
Not to Scale
Gland Assembly
NSN 5975999247518
ADREF No. -
Flange 10 Dia
Welded to Hull
4.4
Hull glands in this section are designed to be fitted to the Vanguard class of
Submarine only. They may be installed singularly in a single pressure hull
insert or grouped within a multipressure hull insert.
34
Dimensions in mm
Not to Scale
Cables HP Side
NSN 6145997248822
Type 50 Ohm Coaxial
Conductor CSA Length
6m
Volts
Amps
No. of Cables
4
211
NSN 6510991688553
ADREF No. Cable Length Inboard (LP ) 3 m
Cable Length Outboard (HP) 15 m
NSN 6510991924968
ADREF No. Cable Length Inboard (LP ) 3 m
Cable Length Outboard (HP) 3 m
79
NSN 6510995912734
ADREF No. Cable Length Inboard (LP ) 15 m
Cable Length Outboard (HP) 18 m
M100x3
22
96.30
Cables LP Side
NSN 6145997248834
Type 50 Ohm Coaxial
Conductor CSA Length
6m
Volts
Amps
No. of Cables
4
`O' Seal
052357
62.95
FIGURE 4.24 Gland and Cable Assembly, Spigot Type Metric, 4 Coaxial 50 Ohms (Type 11)
35
Dimensions in mm
Not to Scale
Cables HP Side
NSN 6145995434475
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Length
6m
Volts
600
Amps
2
No. of Cables
19
211
79
NSN 2040990563620
ADREF No. Cable Length Inboard (LP ) 20 m
Cable Length Outboard (HP) 5 m
M100x3
22
96.30
Cables LP Side
NSN 6145997248842
Type 19 Optimized Screened
Conductor CSA 0.6 mm2
Length
6m
Volts
600
Amps
2
No. of Cables
1
`O' Seal
052357
62.95
FIGURE 4.25 Gland and Cable Assembly, Spigot Type Metric, 19 Screened Pair (Type 1)
36
Dimensions in mm
Not to Scale
Cables HP Side
NSN 6145995434475
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Length
6m
Volts
600
Amps
2
No. of Cables
19
211
M100x3
96.30
22
Cables LP Side
NSN 6145997248836
Type 19 Super Screened
Twisted Pairs
Conductor CSA 0.4 mm2
Length
6m
Volts
600
Amps
1.5
No. of Cables
1
`O' Seal
052357
62.95
FIGURE 4.26 Gland and Cable Assembly, Spigot Type Metric, 19 Screened Pair (Type 2)
37
Dimensions in mm
Not to Scale
Cables HP Side
NSN 6145995434475
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
19
211
79
M100x3
96.30
22
Cables LP Side
NSN 6145997248840
Type Screened Twisted Pair
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
19
`O' Seal
052357
62.95
FIGURE 4.27 Gland and Cable Assembly, Spigot Type Metric, 19 Screened Pair (Type 3)
38
Dimensions in mm
Not to Scale
Cables HP Side
NSN 6145997248824
Type 3 Core Screened
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
19
211
79
M100x3
96.30
22
Cables LP Side
NSN 6145997248837
Type 3 Core Screened
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
19
`O' Seal
052357
62.95
FIGURE 4.28 Gland and Cable Assembly, Spigot Type Metric, 19 Screened Triple (Type 5)
39
Dimensions in mm
Not to Scale
211
Cables HP Side
NSN 6145997248829
Type 3 Screened Pairs
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
3
79
M100x3
96.30
22
Cables LP Side
NSN 6145997248841
Type 9 Screened Pairs
Conductor CSA 0.6 mm2
Volts
600
Amps
2
No. of Cables
1
`O' Seal
052357
62.95
FIGURE 4.29 Gland and Cable Assembly, Spigot Type Metric, 3 X 3 Screened Pair (Type 7)
40
Dimensions in mm
Not to Scale
Cables HP Side
NSN 6145995255127
Type 3 Core
Conductor CSA 4.5 mm2
Volts
440
Amps
26
No. of Cables
1
211
79
M100x3
96.30
22
Cables LP Side
NSN 6145995255127
Type 3 Core
Conductor CSA 4.5 mm2
Volts
440
Amps
26
No. of Cables
1
`O' Seal
052357
62.95
FIGURE 4.30 Gland and Cable Assembly, Spigot Type Metric, 1 Triple (Type 8)
41
Dimensions in mm
Not to Scale
Cables HP Side
NSN 6145997248831
Type Twisted Pair
Conductor CSA 1.5 mm2
Volts
600
Amps
4
No. of Cables
19
211
79
M100x3
96.30
22
Cables LP Side
NSN 6145997248843
Type Twisted Pair
Conductor CSA 1.5 mm2
Volts
600
Amps
4
No. of Cables
19
`O' Seal
052357
62.95
FIGURE 4.31 Gland and Cable Assembly, Spigot Type Metric, 19 Pair
42
Dimensions in mm
Not to Scale
274
Cables HP Side
NSN Type 52 Quad Tinned Copper
Wire Screen
Conductor CSA 0.25 mm2
Length
200 m
Volts
500
Amps
0.75
No. of Cables
1
79
M100x3
96.30
22
Cables LP Side
NSN Type 208 Conductor Shielded
Jacketed Cable
Conductor CSA 0.15 mm2
Length
5m
Volts
600
Amps
0.5
No. of Cables
1
`O' Seal
052357
62.95
FIGURE 4.32 Gland and Cable Assembly, Spigot Type Metric, 1 X 52 Quad
43
Dimensions in mm
Not to Scale
Cables HP Side
NSN 6145997248833
Type Single Core
Conductor CSA 6 mm2
Volts
600
Amps
25
No. of Cables
4
211
79
M100x3
96.30
22
Cables LP Side
NSN 6145997248845
Type Single Core
Conductor CSA 6 mm2
Volts
600
Amps
25
No. of Cables
4
`O' Seal
052357
62.95
FIGURE 4.33 Gland and Cable Assembly, Spigot Type Metric, 4 Single Core
44
5.
45
ANNEX A.
RELATED DOCUMENTS
A.1
Drawing
SDN 007 038 075
Drawing
SDN 007 044 060
Drawing
SDN 007 502 353
Drawing
SDN 007 509 367
Drawing
SDN 007 528 045
Drawing
SDN 007 528 046
Drawing
SDN 007 528 047
Drawing
SDN 007 528 048
Drawing
SDN 007 528 049
46
Drawing
SDN 007 528 050
Drawing
SDN 007 528 051
Drawing
SDN 007 528 052
Drawing
SDN 007 528 433
Drawing
SDN 007 528 756
Drawing
SDN 007 531 320
47
ANNEX B.
ABBREVIATIONS AND DEFINITIONS
B.1
B.2
CSA
CrossSectional Area
CSP
Chlorosulphonated Polyethylene
DPA
DLO
HP
High Pressure
LP
Low Pressure
MLS
MOD
Ministry of Defence
NES
NSN
PCD
PCP
Polychloroprene
PVC
Polyvinyl Chloride
SDN
SSA
SSK
SSN
SSBN
48
ANNEX C.
INDEX OF NATO STOCK NUMBERS
NATO STOCK No
PAGE No
2040992192669
4.13
2040990563620
4.30
2040998677897
4.38
5330999237760
Various
5330999237764
4.18
5975990524083
4.30
5975991799257
4.33
5975994561492
4.17
5975995224392
4.6
5975995224393
4.5
5975995224394
4.7
5975995224395
4.8
5975995224397
4.3
5975995224398
4.4
5975995224399
4.10
5975995224400
4.20
5975995226244
4.16
5975996606050
4.32
5975997654444
4.31
5975997948800
4.29
5975998499861
4.35
5975995253848
4.18
5975999249194
4.26
5985999247518
4.27
6145991116772
4.24
6145995216866
4.25
6145995216965
4.25
6145995227875
6145995227877
4.3
6145995252037
4.4
6145995255127
4.10 / 4.35
6145995271312
4.24
6145995278993
4.7
6145995278994
4.8
6145995434475
49
NA
TO
STOCK
No
P AGE
No
6145997248822
4.9 / 4.29
6145997248824
4.13 / 4.33
6145997248829
4.34
6145997248831
4.6 / 4.36
6145997248833
4.4 / 4.38
6145997248834
4.9 / 4.29
6145997248836
4.12 / 4.31
6145997248837
4.13 / 4.33
6145997248840
6145997248841
4.34
6145997248842
4.11 / 4.30
6145997248843
4.36
6145997248845
4.38
6150991259056
4.36
6510991688553
4.29
6510991924968
4.29
6510995912734
4.29
50
DStan Helpdesk
Tel 0141 224 2531/2
Fax 0141 224 2503
Internet e-mail enquiries@dstan.mod.uk
File Reference
The DStan file reference relating to work on this standard is D/DStan/69/02/524 Pt 1.
Contract Requirements
When Defence Standards are incorporated into contracts users are responsible for their correct
application and for complying with contractual and statutory requirements. Compliance with
a Defence Standard does not in itself confer immunity from legal obligations.
Revision of Defence Standards
Defence Standards are revised as necessary by up issue or amendment. It is important that
users of Defence Standards should ascertain that they are in possession of the latest issue or
amendment. Information on all Defence Standards is contained in Def Stan 00-00 Standards
for Defence Part 3 , Index of Standards for Defence Procurement Section 4 Index of Defence
Standards and Defence Specifications published annually and supplemented regularly by
Standards in Defence News (SID News). Any person who, when making use of a Defence
Standard encounters an inaccuracy or ambiguity is requested to notify the Directorate of
Standardization (DStan) without delay in order that the matter may be investigated and
appropriate action taken.