Vous êtes sur la page 1sur 4

Power Engineering Software and Solutions

CYME Power Engineering Software

New Features CYME 5.04


Cooper Power Systems is proud to announce the release of the latest CYME
5.04 Power Engineering Software. CYME 5.04 extends its analytic and design
capabilities with new engineering analysis tools, new equipment modeling
capabilities and enhancements in one-line diagram editing and reporting
functionalities. CYME 5.04 is a comprehensive and reliable tool that satisfies the
need of power engineers working with any distribution, industrial and transmission
network.

CYME 5.04 for Distribution, Industrial and Transmission Systems


With the numerous enhancements and additions to the
software, this new version of CYME continues to deliver
quality and cutting-edge solution for distribution, industrial and
transmission system studies.
Growing alongside the Distributed Energy Resources (DER)
developments, CYME continues to invest in its ability to address
the needs of engineers who need tools to study various aspects
of DER interconnection. New tools include:
Long-Term Dynamics Analysis
Single-phase DER short-circuit contribution
Anti-Islanding protection for inverter-based distributed
generation (DG)
Analyses such as Load Flow, Optimal Capacitor Placement
and Harmonics have been enhanced with new options. The
new Fault Flow calculation engine is more robust and effective,
while fully supporting complex phase merging configurations like
most CYME analyses do. Optimal Power Flow (OPF) analysis,
an advanced system planning tool, has also been added. An
improved Advanced Project Management tool provides you a
powerful tool to create scenarios, compare, correct and merge
your study files in order to make your project planning hasslefree.
Equipment modeling capabilities have been extended with the
addition of new equipments and enhancements of existing
ones. Voltage regulator modeling now offers the by-phase
type and recognizes the distinction of its construction type.
Overhead line modeling has been revamped with detailed
spacing modeling. New additions to the equipment library
include busway, switchable shunt banks and more.

www.cyme.com | www.cooperpowereas.com

Cooper Power Systems and CYME are valuable trademarks of Cooper Industries in the U.S. and other countries.
You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries.
2011 Cooper Industries. All Rights Reserved.

New Features

CYME 5.04 for Distribution, Industrial and Transmission Systems.

Distribution System Analysis

Advanced Project Manager

Long-Term Dynamics Analysis

CYMEs Advanced Project Management is


equipped with tools to help power engineers
work with their studies and plan their projects
in the most effective manner. This module
includes:

The Long-Term Dynamics Analysis is a timeseries simulation catered for the study of how
DER impact network controls such as load
tap changers and capacitors.
The variable DER output is affected by:
Insolation curves
Wind speed curves
Load and other generator profile curves
To properly simulate tap changing and
capacitor switching, the analysis also takes
into account:
Regulators tap changer delay,
mechanism delay, timer reset modes
Capacitors close delay, trip delay,
breaker delay

Project Editing and Time Positioning


create scenarios, position the study at
selected modification
Study Correction Wizard resolve any
error due to modification mismatch
between study files and database.
Study Comparison and Merge capability
compare two self-contained studies,
two scenarios or locations within a study.
Merge selected modifications from
studies.
Network Versioning create multiple
versions of the same network within the
same database.
Fault Analysis

Short-Circuit and Fault Flow analyzes dialog


boxes have been redesigned, and a new
fault flow algorithm that extends its analytical
capabilities is used. Features included:
Short-Circuit in phase domain for
multiphase networks
LLLG fault available
Single-phase DER contribution
Full Phase-Merging Capability

The analytical capability of more CYME


analyses have been extended to fully support
phase-merging, including bidirectional flow
sections.
Load flow
Short Circuit
Fault Flow
Load Allocation

Regulator Enhancements

The regulator model has been enhanced with:


Construction Type A and B
Maximum Current Rating
By-phase Regulator
Extended Bonus rating Capability
Analysis Enhancements

Enhancements are also made to the following


analyses:

Long-Term Dynamics

Load Flow temperature coefficient

Capacitor placement
Load Balancing

Load Allocation constraints relaxation


for convergence

Harmonics

Capacitor Placement location selection

Locked Rotor

Harmonic Analysis new line and cable


models

Load Flow Contingency

CYME International ( part of Cooper Power Systems)


1485 Roberval, Suite 104
St-Bruno, QC Canada J3V 3P8
www.cyme.com | www.cooperpowereas.com
P: 450.461.3655
info@cyme.com
F: 450.461.0966
P: 800.361.3627 (Canada and USA)
B1170-11038 November 2011

New Features

Transmission and Industrial


System Analysis
Smart Grid Solution with Optimal Power Flow

CYMEs Optimal Power Flow (OPF) analysis


is an advanced system planning tool which
automatically finds optimal device settings
to satisfy selected objectives within specific
constraints. It is a powerful solution for
system performance optimization and costefficiency improvement.

CYME 5.04 for Distribution, Industrial and Transmission Systems.

FACTS Devices

To complement the implementation of


transmission line models, FACTS devices
have been added. These devices are:
STATCOM
UPFC

A choice of 11 different objectives is


offered, and they can be used individually or
simultaneously. Among these objectives are:
Minimize reactive power losses

DC Links

Minimize load shedding

CYME 5.04 has also incorporated the design


of HVDC links.

Maximize flat voltage profile


Minimize fuel cost
Controllable system variables include
generator power settings, transformer tap
settings, load participating in load shedding
and switchable reactive bank control.

Detailed rectifier and inverter transformer


modeling
Harmonic spectrum according to rectifier
and inverter parameters

Infeasibility handling and constraints relaxation


offer greater flexibility in system convergence
and OPF will always provide you with a
solution for better system asset management.
Transmission Line Models

Switchable Shunt Banks

Tower Configurations have been added to


CYME 5.04.

This new device would allow a group of


capacitor banks or reactor banks to be
switched on/off to control the voltage at a
given bus.

Double-circuit configurations and single circuit


configurations are now available, making the
modeling of a variety of tower configurations
possible.

Harmonic Line Models

The Harmonic Analysis has been enhanced to


include new line models such as:
Distributed transposed, with skin effect
Distributed transposed, frequencydependent
Distributed untransposed

CYME International ( part of Cooper Power Systems)


1485 Roberval, Suite 104
St-Bruno, QC Canada J3V 3P8
www.cyme.com | www.cooperpowereas.com
P: 450.461.3655
info@cyme.com
F: 450.461.0966
P: 800.361.3627 (Canada and USA)
2011 Cooper Industries. All rights reserved.

New Features

Transmission and Industrial


System Analysis
Variable Frequency Drive

The variable frequency drive (VFD) can now be


represented as separate equipment with its
own database and network settings. The VFD
can now be connected to an induction motor
with a secondary cable and offers speed
control for motor starting analysis purposes.
Depending on the operating frequency, the
VFD can either be in constant current or in
constant power operating mode.

CYME 5.04 for Distribution, Industrial and Transmission Systems.

Series Fault and Simultaneous Fault Analyses

Two new fault analyzes have been added to


CYME 5.04:
Series faults conditions of one-phase
open, two-phase open or three-phase
series unbalance conditions
Simultaneous faults which could be a
shunt fault at more than one location or a
combination of shunt and series faults.

Anti-Islanding Protection
New Equipments

New equipments added to this version


include:

This is implemented for electronically coupled


DG:
Photovoltaic (PV)

Busway

Wind turbines

Phase-shifting transformer

Micro turbines

Reactive power flow control transformer

Solid oxide fuel cells

Impedance relay
Frequency droop relay

These controls are activated when islanding


is detected under transient conditions to
disconnect any DG when certain voltage and
frequency criteria are met.

Motor different RPM mode

The Gear Ratio is now an available option


to represent the case when the load RPM is
different than the motor synchronous speed.

CYME International ( part of Cooper Power Systems)


1485 Roberval, Suite 104
St-Bruno, QC Canada J3V 3P8
www.cyme.com | www.cooperpowereas.com
P: 450.461.3655
info@cyme.com
F: 450.461.0966
P: 800.361.3627 (Canada and USA)
B1170-11038 November 2011