2GIG-GB1-345

GLASS BREAK DETECTOR


INSTALLATION INSTRUCTIONS

Figure 2 Glass Break DetectorBase

TheGlassBreakDetector(2GIGGB1345)isafullysupervised,
tamperprotected,ceilingorwallmountedunit.Itcommunicates
withthecontrolpanelusingthe345MHzfrequency.Thedetector
providesa15ft(4.6m)maximumdetectionrange,360maximum
horizontalsensingangle,anddualstageglassbreakdetection.

Contents
Verifythatthepackageincludesthefollowing:
1GlassBreakDetector(withMountingBase)
2LithiumBatteries
3PlasticWallAnchorswithScrews
Figure 1 LED Indicators

A
B

Tamperswitch
Batterycompartments(REDtabslocatedbehindcompartments)

NOTE: Ifclosingthedetectorwhenbatteriesarenotpresent,

gentlypushtheREDtabsonthebacksideofthebaseaway
fromthedetector(seeFigure2GlassBreakDetectorBase).
5

Holdingthecover,aligntheimprintedarrowsonthedetectorand
thentwistthecoverinaclockwisemotiontoclosetheunit.

WARNING: Failuretofollowthesewarningsandinstructionscan
A
B
C
D

leadtoheatgeneration,rupture,leakage,explosion,fire,or
otherinjury,ordamage.Donotinsertthebatteryintothe
compartmentinthewrongdirection.Alwaysreplacethe
batterywiththesameorequivalenttype(see"Specifications"
onpage2).Neverrechargeordisassemblethebattery.Never
placethebatteryinfireorwater.Alwayskeepbatteriesaway
fromsmallchildren.Ifbatteriesareswallowed,promptlysee
adoctor.

REDLED
GREENLED
TESTbutton
Imprintedarrow(foralignmentofcoverandbase)

Inserting and Replacing the Batteries


Toinsertorreplacethebatteries:
1 Unwrapthedetector.
2 Holdingthecoverandbase,twistthecoverinacounterclockwise
motion.Whentheimprintedarrowsonthesideofthedetector
arealigned,separatetheunit.
3 Removetheoldbatteries.
IMPORTANT: Alwaysdisposeand/orrecycleusedbatteriesin

accordancewiththehazardouswasterecoveryandrecycling
regulationsforyourlocation.Yourcity,state,orcountrymay
alsorequireyoutocomplywithadditionalhandling,recycling,
anddisposalrequirements.
4

Insertthebatteriesinthecompartment.Alwaysmatchtheplus(+)
signonthebatterywiththeflatsideofthecompartmentandthe
minus()signonthebatterywiththespringsideofthe
compartment.
Ittakesapproximatelyfive(5)secondsforthedetectortopower
ON.

Wall Mounting
Whenwallmounted,thedetectorprovidesprotectioncoverageon
theoppositeoradjacentwindow.Windowsonthesamewallasthe
detectorarenotprotected.
Tomountthedetectortoawall:
1 Ifnotalreadyinstalled,insertthebatteries(see"Insertingand
ReplacingtheBatteries"onpage1).
2 Withthecoveroff,placethebaseofthedetectorontheadjacent
oroppositewallfromthewindowbeingprotected.
3 Usethethree(3)PlasticWallAnchors(provided)tomountthe
baseofthedetectortothewall.
IMPORTANT: AlwaysmountthedetectorsotheTestbuttonisin

thedownwardposition.
4

Holdingthecover,aligntheimprintedarrows.Thenusea
clockwisetwistmotiontolockthecoverintoplace.

Copyright 2015 Nortek Security & Control LLC 1

Glass Break Detector | Installation Instructions

Glass Type and Thickness

REGULATORY INFORMATION

Theminimumsizeandshapeforallglasstypesis11x11in(28x28
cm)square.Glassmustbeframedinthewalloftheroomor
mountedina36in(91cm)barrier.
Figure 3 Glass Type and Thickness

FCC Notice

Type

MinimumtoMaximumThickness

Plate
Tempered
SealedInsula ng

1/81/4in(3.26.4mm)
1/81/4in(3.26.4mm)
1/81/4in(3.26.4mm)

Sealedinsula ngglasstypesareprotectedonlyifbothplatesofglassarebroken.

SPECIFICATIONS
WirelessSignalRange
CodeOutputs
TransmitterFrequency
UniqueIDCodes
SupervisoryInterval
SensorType
MaximumHorizontalSensing
Angle
Dimensions(DxH)
Weight(includingbattery&
bracket)
HousingMaterial
Color
OperatingTemperatureLimits
RelativeHumidity
Battery(included,notinstalled)
ApprovedGlassBreakSimulator
Certification

300ft(91.44m),openair,withWireless
ControlPanel
Alarm;AlarmRestore;Tamper;Tamper
Restore;Supervisory;LowBattery
345.00MHz(crystalcontrolled)
Overone(1)milliondifferentcode
combinations
70minutes
Singlemicrophone,dualstagethud,and
crash
360forceilingmountor180forwall
mount
4.55x1.9in(11.56x4.83cm)
5.1oz(144.6g)
ABSPlastic
White
32120F(049C)
590%NonCondensing
Two(2)CR123A3VorequivalentLithium
batteries
FG701GlassbreakSimulator
Anatel,ETL,FCC,IC,IFETEL,andNOM

ThisdevicecomplieswithPart15oftheFCC'sRules.Operationis
subjecttothefollowingtwoconditions:
1 Thisdevicemaynotcauseharmfulinterference,and
2 Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
Thisequipmenthasbeentestedandfoundtocomplywiththelimits
foraClassBdigitaldevice,pursuanttoPart15oftheFCCRules.
Theselimitsaredesignedtoprovidereasonableprotectionagainst
harmfulinterferenceinaresidentialinstallation.
Thisequipmentgenerates,usesandcanradiateradiofrequency
energyand,ifnotinstalledandusedinaccordancewiththe
instructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterference
willnotoccurinaparticularinstallation.Ifthisequipmentdoes
causeharmfulinterferencetoradioortelevisionreception,which
canbedeterminedbyturningtheequipmentoffandon,theuseris
encouragedtotrytocorrecttheinterferencebyoneormoreofthe
followingmeasures:
Reorientorrelocatethereceivingantenna.
Increasetheseparationbetweentheequipmentand
receiver.
Connecttheequipmentintoanoutletonacircuitdifferent
fromthattowhichthereceiverisconnected.
Consultthedealeroranexperiencedradio/TVtechnicianfor
help.
ThisproductcomplieswithFCCradiationexposurelimitsforan
uncontrolledenvironment.Avoidoperatingthisproductata
distancelessthan20cmfromtheuser.
CAUTION: Anychangedormodificationsnotexpressly

approvedbythepartyresponsibleforcompliancecould
voidtheuser'sauthoritytooperatethisequipment.

Industry Canada (IC) Compliance


ThisdevicecomplieswithIndustryCanadalicenseexemptRSS
standard(s).Operationissubjecttothefollowingtwoconditions:(1)
thisdevicemaynotcauseinterference,and(2)thisdevicemust
acceptanyinterference,includinginterferencethatmaycause
undesiredoperationofthedevice.
Repairstocertifiedequipmentshouldbemadebyanauthorized
Canadianmaintenancefacilitydesignatedbythesupplier.Any
repairsoralterationsmadebytheusertothisequipment,or
equipmentmalfunctions,maygivethetelecommunications
companycausetorequesttheusertodisconnecttheequipment.
Usersshouldensurefortheirownprotectionthattheelectrical
groundconnectionsofthepowerutility,telephonelinesand
internalmetallicwaterpipesystem,ifpresent,areconnected
together.Thisprecautionmaybeparticularlyimportantinrural
areas.

2 Copyright 2015 Nortek Security & Control LLC

LIMITED WARRANTY
ThisNortekSecurity&ControlLLCproductiswarrantedagainst
defectsinmaterialandworkmanshipfortwo(2)years.Thiswarranty
extendsonlytowholesalecustomerswhobuydirectfromNortek
Security&ControlLLCorthroughNortekSecurity&ControlLLCs
normaldistributionchannels.NortekSecurity&ControlLLCdoesnot
warrantthisproducttoconsumers.Consumersshouldinquirefrom
theirsellingdealerastothenatureofthedealerswarranty,ifany.
TherearenoobligationsorliabilitiesonthepartofNortekSecurity&
ControlLLCforconsequentialdamagesarisingoutoforinconnection
withuseorperformanceofthisproductorotherindirectdamages
withrespecttolossofproperty,revenue,orprofit,orcostofremoval,
installation,orreinstallation.Allimpliedwarrantiesforfunctionality,
arevalidonlyuntilthewarrantyexpires.ThisNortekSecurity&
ControlLLCWarrantyisinlieuofallotherwarrantiesexpressedor
implied.

2GIG
1950CaminoVidaRoble,Suite150
Carlsbad,CA92008USA
FortechnicalsupportintheUSAandCanada:
8552GIGTECH(8552444832)
Email:2gigtechsupport@nortek.com
Visitwebsitefortechnicalsupporthoursofoperation
FortechnicalsupportoutsideoftheUSAandCanada:
Contactyourregionaldistributor
Visitdealer.2gig.comforalistofdistributorsinyourregion
10004955Rev.A
ANortekCompany

Copyright 2015 Nortek Security & Control LLC 3