ANALISIS Y DISEO DE CIMIENTOS CORRIDOS

DATOS:
Resistencia del terrreno =
S/C =
Df =
Ko =
s =
N.P.T. =
Nmero de Pisos =
Tabiquera equivalente =
Espesor de muro =

0.80 kg/cm2
200 kg/m2
0.90 m
3000 Ton/m3
0.15 Ton/m3
0.15
2
0 kg/m2
0.15 m

f'c =
Piso =
H asumido =
ca =
cs =
Columna =
Viga =
gladrillo =
recub. =

CL

140 kg/cm2
15.00 cm
0.60 m
2.40 Ton/m3
2.00 Ton/m3
25 x
25 x
1800 kg/m2
7.50 cm

CL

L = 1.37 m
S/C = 100 kg/m2

0.20 m

2.40 m
200 kg/m2
0.20 m

2.40 m
200 kg/m2
0.20 m

2.60 m
N.P.T. = 0.15
0.15 m
0.00 m
0.90 m

h
b

SOLUCION:
1. DETERMINACION DE LA PRESION NETA DEL TERRENO
*nt = *t - S/C - h*ca - ep*cs - er*s

25
25

*nt = 6060 kg/m2


2. METRADO DE CARGAS
Peso propio de losa =
822.00 kg/m
Peso muerto =
300.00 kg/m
Peso tabiqera equivalente =
0.00 kg/m
Peso Vigas =
300.00 kg/m
Peso Muro = 1323.00 kg/m
Peso Sobrecimiento =
315.00 kg/m
Peso Cobertura =
137.00 kg/m
S/C =
411.00 kg/m
g = 3608.00 kg/m
3. DETERMINACION DEL ANCHO DEL CIMIENTO

A=

P S
nt

= 0.60 m

Se toma:

= 0.70 m

4. DETERMINACION DE LA ALTURA (h) DEL CIMIENTO

Presin ltima:

U =

Pu
bL

= 7908 kg/m2

Momento ltimo:

1
M u = W uX 2
2

0.43 m

Mu =

714.15 kg-m/m

u f r =1 . 3 f 'c
fr = 9998.17 kg/m2
OK

h=

6M u
bf r

24.74 cm

Se toma:

= 60.00 cm

Suficiente

Si necesita refuerzo:

g=
d=
As =
s=

5/8 ''
51.71 cm
9.31 cm2
21.49 cm

5/8 ''

As =
a=
Mu =

10.00 cm2
3.53 cm
1887790.37 kg-m/m

OK!

Verificacin:

Ag = 2

20.00 cm

Vous aimerez peut-être aussi