REV: 0
DOC NO:QP-15
QUALITY PROCEDURE
PROPERTY OF
ITECSOLUTIONS
AND
CONTROLLED
BY
THE
Rev
0
Date
23/12/2013
Prepared by
Y.ARUN
Branch Manager
SIGNATURE/STAMP
SIGNATURE/STAMP
This Document is property of IQG. No reproduction is allowed without prior to written permission
from the management of IQG. Violators may be prosecuted.
REV: 0
DOC NO:QP-15
OBJECTIVE
This procedures establishes conditions required for performing non-destructive testing by
means of magnetic particle testing by using yoke technique, to be carried out by Itecsolutions
Quality Group Pte Ltd.
2.0
ASME SECTION V
ASTM E709
BS EN 1290
BS EN 10228-1
2010 Edition
2001 Edition
1998 Edition
1999 Edition
This Document is property of IQG. No reproduction is allowed without prior to written permission
from the management of IQG. Violators may be prosecuted.
3.0
REV: 0
DOC NO:QP-15
PROCEDURES
MAGNETIZATION CURRENT
Alternate current shall be used.
3.5
This Document is property of IQG. No reproduction is allowed without prior to written permission
from the management of IQG. Violators may be prosecuted.
Page
9 of 9
EFFECTIVE DATE:23
DECcontrast
2013 andREV:
0
DOC
PAGE the
NO:wet
mobility,
sensitivity.
In
caseNO:QP-15
of the wet method,
Magnetic
Particle shall be pressurized spray cans, Eg. Magnaflux 7HF or Ardrox 800/3.
3.5.2 Should can type being used, the bath strength shall have the concentration of
1.2ml to 2.4ml from a 100ml sample for magnetic black ink.
3.5.3 White background contrast medium shall be white emulsion paint or in ready
pressurized spray cans, E.g. Magnaflux 9WCP or Ardrox 8386 W rapid dry
white lacquer.
3.6
INSPECTION CONDITIONS
3.6.1 Surface Preparation
The surface to be inspected and the adjacent region (at least 25 mm) shall be
free from scale, slag, paint and other materials, which might interfere in the
inspection execution.
3.6.2 Lighting Condition
When testing / inspection is performed under normal light (white), the light
intensity measured on the test piece surface shall be at least 1000 lux
(measured with a light meter) daylight or a 100 Watt tungsten filament bulb at
a distance of 8 inches or 200 mm from the surface.
3.6.3 Temperature
During execution of inspection, the test piece temperature shall not be greater
than 300C for the dry method and 60C for the wet method.
3.6.4 Overlapping
The inspection shall be performed with overlapping enough to assure that
100% of the area to be inspected is covered with the required sensitivity. At
least two separate tests shall be performed in each area, so that the magnetic
flux lines of the second test are approximately perpendicular to those of the
first one.
This Document is property of IQG. No reproduction is allowed without prior to written permission
from the management of IQG. Violators may be prosecuted.
REV: 0
DOC NO:QP-15
Checking of the inspection efficiency shall be done in the beginning of each working
period using the magnetic field indicator shown in Appendix 1, Figure 1. The
magnetic field in the inspection useful area shall be considered as adequate in case a
well defined line of magnetic particles appear on the face of the indicator.
(1)
PREPARE
SURFACE
(2)
APPLY
CONTRAST
MEDIA
(3)
DRY PARTS
(6)
(5)
(4)
INTERPRET/
APPLY
POSITION
EVALUATE
MAGNETIC
This Document is property of IQG. No reproduction is allowed without prior YOKE
to written permission
MAGNETIZE
from the management of IQG. Violators mayMEDIUM
be prosecuted.
REV: 0
DOC NO:QP-15
This Document is property of IQG. No reproduction is allowed without prior to written permission
from the management of IQG. Violators may be prosecuted.
EFFECTIVE DATE:23
2013
API 1104
DEC
API 650
API RP 2X
BS EN 1291
BS EN ISO 23278
2007 Edition
2004 Edition
1998 Edition
2009 Edition
3.12 DEMAGNETIZATION
Not applicable
3.13 FINAL CLEANING
Cleaning shall be done whenever there is interference on the next process of this
procedure.
3.14 SAFETY
- Refer to QP 18 Safety.
4.0
RECORDS
Results of inspection shall be recorded in a report form as per Appendix 2 and a copy to be
retained by company for at least 5 years.
5.0 APPENDICES
Appendix 1 - Fig 1 Magnetic Particle Field Indicator.
Appendix 2 - Magnetic Particle Test Report.
This Document is property of IQG. No reproduction is allowed without prior to written permission
from the management of IQG. Violators may be prosecuted.
REV: 0
DOC NO:QP-15
APPENDIX 1
This Document is property of IQG. No reproduction is allowed without prior to written permission
from the management of IQG. Violators may be prosecuted.
REV: 0
DOC NO:QP-15
APPENDIX 2
This Document is property of IQG. No reproduction is allowed without prior to written permission
from the management of IQG. Violators may be prosecuted.
REV: 0
DOC NO:QP-15
This Document is property of IQG. No reproduction is allowed without prior to written permission
from the management of IQG. Violators may be prosecuted.