Vous êtes sur la page 1sur 5

P&ID Jedson Program

1- How to draw a primary/secondary line?


Piping Routing Primary/secondary line.
2- Properties
We define size(diameter) - plan no.

Determined in 2 ways:
a) Properties of line( right bottom of window).
b) Labels (In piping Labels)
Define constants status:
New
Existing
Future.
3- Valves Catalog Explorer.
Valves choose type of valves Determine size + diameter consistency
Then: label for valves piping components commodity code Nominal
diameter.
Plug= miniature cap.

Get the plug from fittings (piping fittingspipe comp.)


2 ways to move fittings move OR drag
NB: In order to stop termination inconsistency Fittings end
components End of line
-

Flow Direction: Label piping segment flow direction.


Text: Design Annotation Labels Item notes & Labels (Then fill in
note text-properties)
Sensors, Pressure gauge Under Instruments

Different types of links and most common:


- Connect to process
- Electric line
- Software link
Are found in Instrumentation Signal line.
How to find the instruments?
Instrumentation:
- Actuators
- Gaps
.
.
.
Disc single line
where?
Disc: Instrumentation Offline Without implied Components
DCS: Instrumentation Offline In system Functions.
Arrows for electrical wires- From Design
NB: Dont leave an instrument without drawing code.
Select all instruments by Ctrl, then modify in properties window.
For instruments: change sequence no. , Measured variable and instrument
type.
Instrument Type

Measured
Variable

SV

Breakers:
Piping Segment breaker

Reducer:
In fittings Diameter Change.
1.
2.
3.
4.
5.
6.

Get reducer
Label
Info for label
Valves
Electrical lines
Processes

5 most common types of breakers:


Diameter / Group / Insulation / Heat Tracing / Material

We have to always put the flow direction in:


Piping pipe segments flow direction

Ball valve: always full port.

How to link drawings to each others?

Symbol Piping piping OPCs Off drawing

Linking OPCs

Eng. Data editor (Top)


Piping ok OPC Ok

Comments from the Eng. In Alabama:

Check valve: || always or


Arrows are not to be placed on end caps
Grid density always set at 0.05
Equipment name is ALWAYS LABEL not Note.
Instruments Symbol without implied components
FO? FC? Difference?
Drip Leg? Orthogonal Line?

Control angle valve: from instruments Valve Angle 2 way generic


body angle
Valves controlled electrically from Instruments.
In reducers, larger size x smaller size
Function block placed as a flag?
I/P function near valve instrument, its symbol is Convert Function T/R found
in InstrumentFunctionConvert Function T/R
We put the value I/P in Properties/Instrument Function Value.
Checking drawing digitally.
Engineering data Each component
Pipe Run.
Process line
Instrument
Equipment
In order to check the connect to process, we put Pipe Run Ok Connect
to process.

Where to get insulation from?


Piping Labels Piping Segments.

Line number:
Piping Labels Piping Segments