Voith sets the standards in the energy, oil & gas, paper, raw
materials and transportation & automotive markets.
Founded in 1867, Voith employs more than 43000 people,
generates Euro 5.7 billion in sales, operates in over 50
countries around the world and is today one of the largest
family-owned companies in Europe.
Typical applications
Power plants
Oil and gas industry
Chemical industry
District heating plants
Iron and steel industry
Water management
Increase Your
System Availability.
System availability is particularly important in power plants, refineries, oil
platforms, or other industrial uses. Unscheduled downtime can result in
considerable loss of revenue and excess costs. Thats not something our
customers have to worry about.
15000
Currently in use in more than
4x 58
years
Service life up to
More than
of use.
Power ratings up to
10000 kW
Operating temperatures from
-40C to +50C
(ambient temperature)
Variable speed fluid coupling 3D sectional diagram and simplified longitudinal section
1 2
7
6
8
1 Pump wheel
5 Scoop tube
2 Turbine wheel
6 Cooler
3 Shell
7 Oil pump
8 Oil tank
4 5
Torque curves
Operating range
The performance diagram shows the transmittable coupling
torques MK for various scoop tube positions versus the output
speed. The desired output speed is the result of a stable
intersection point of the coupling torque MK and the load
torque (load characteristic).
Torque curves for different driven machines in the variable speed fluid coupling characteristic diagram
40%
125
50%
60%
70%
80% 90%
100%
III
Smin
1
100
I
75
MK in %
30%
II
2
3
4
50
20%
25
10%
IV
0%
0
50
100
Operating ranges
The exact characteristic curve is dependent on
the size of the coupling, the amount circulating,
and the oil viscosity.
I , IV Starting range
Parameters
Scoop tube position in % of scoop tube stroke.
M K
Coupling torque
II Control range
n1
Input speed
n2
Output speed
a large ith
e
b
y
a
w
M
picture
format ment here?
state
Type
Features
SVTL
SVNL
SVNL G
The SVNL features a housing split horizontally. Shafts in the SVNL have antifriction
bearings; SVNL G is equipped with sleeve
bearings.
SVL M
The SVL M features an especially high power density and has a cast iron housing split
horizontally. The shafts are equipped with
sleeve bearings.
SVNL vert.
SVTL Models
The SVTL coupling is a self-supported design featuring a tunnel housing. The rotating parts are encased in an enclosed
oil-proof housing. Connecting couplings link the electric motor
and driven machine with the variable speed fluid coupling. The
oil tank is built into the housing and the oil pump is driven by
the input shaft. The shafts are equipped with antifriction bearings lubricated by a mechanically driven lubricating oil pump
in the variable speed fluid coupling.
SVTL model variable speed fluid coupling and simplified longitudinal section
1 2
7
6
8
10
1 Pump wheel
5 Scoop tube
2 Turbine wheel
6 Cooler
3 Shell
7 Oil pump
8 Oil tank
4 5
SVTL dimensions
TL
33
HP
8000
7000
2
56
12
SV
48
TL
SV
.2
22
TL
C
Oil capacity
[mm]
[l]
Weight
[kg]
1120
630
1780
250
1145
630
1780
250
900
1255
800
1780
500
1200
1145
630
1780
250
970
1255
800
1780
500
1260
562 SVTL HP
1358
800
1350
450
2200
562 SVTL 33
1358
800
1350
450
2200
562 SVTL 33 HP
1358
800
1350
450
2200
1310
750
2000
300
1200
1310
750
2000
300
1300
1469
725
1400
400
1750
1469
725
1400
400
1800
850
,0
SV
SV
42
21
TL
SV
2
B
[mm]
48
56
TL
21
TL
21
TL
SV
0
65
100
80
22
-2
21
48
-6
,3
SV
-1
22
TL
0
200
SV
86
TL
SV
300
A
[mm]
12
2
56
56
2,
600
500
400
TL
SV
TL
TL
SV
SV
0
75
1000
800
75
A
500
600
750
3000 3600
Rated power P1 in kW
TL
HP
22
2000
56
-1
2,
3000
60
50
400
33
SV
5000
4000
Type
11
12
The oil tank is built into the housing and a centrifugal pump
serves as the oil pump (some models feature a gear wheel
pump) and is driven directly by the input shaft. SVNL coupling
main shafts are equipped with antifriction bearings. The bearings are lubricated with pressurized oil.
SVNL G coupling main shafts are equipped with sleeve bearings. The bearings are force lubricated using pressurized oil.
An electrically driven auxiliary lubricating pump is attached for
priming lubrication prior to startup.
6
6
7
1 Pump wheel
5 Scoop tube
2 Turbine wheel
6 Cooler
3 Shell
7 Oil pump
8 Oil tank
12
1 Pump wheel
5 Scoop tube
2 Turbine wheel
6 Cooler
3 Shell
7 Oil pump
8 Oil tank
SVNL G dimensions
10000
3G
8000
2S
Type
620 SVNL 33 G
1485
900
2160
682 SVNL 33 G
1485
900
2160
430
3980
3150
800
2400 1000
2500
12500
3150
800
2400 1000
2500
13800
VN
NL
L3
12
3G
-80
68
-80
12
NL
3800
13
62
30
430
Weight
[kg]
0S
SV
40
SV
3000
15
Rated power P1 in kW
4000
2000
VN
5000
L3
6000
Oil
capacity
[l]
A
B
C
D
[mm] [mm] [mm] [mm]
1000
800
600
500
400
500 600
750
300
400
SVNL dimensions
Type
A
[mm]
B
[mm]
5000
4000
1760
1060 1920
780
3650
1950
1060 1920
780
3650
1950
1060 1920
780
3800
1950
1060 1920
780
4000
1210 SVNL HP
1950
1060 1920
780
4000
NL
22
-2
8000
600
500
400
1
12 210
10 SV
50 SVN NL H
L P
SV
10
NL 2100
32
2
.
2SV
32 1
NL
.1
22
-3
2.
1
1000
800
Oil capacity
[l]
Weight
[kg]
11
300
200
100
80
60
50
400
Rated power P1 in kW
2000
86
SV
3000
C
[mm]
500
600
750
3000 3600
13
SVL M Model
The SVL M coupling model is a self-supported design with a
high power density. The input and output shaft are each individually encased in a cast iron housing. Connecting couplings
link the main motor and driven machine with the variable
speed fluid coupling.
1 2 3
12
11
10
1 Pump wheel
2 Turbine wheel
9 Auxiliary lubricating
pump
3 Shell
9
14
4 Coupling housing
5 Oil tank
6 Oil pump
7 Scoop tube
14
SVL M dimensions
40000
30000
0
75
10000
68
62
4000
62
2000
0
51
1000
2000
SV
VL
SV
SV
SV
C
[mm]
D
Oil capacity
[mm]
[l]
Weight
[kg]
464 SVL M
1855
720
1540
1280
1460
6700
510 SVL M
1985
720
1540
1280
1460
6800
562 SVL M
2045
720
1540
1280
1460
6900
620 SVL M
2115
720
1540
1280
1460
7000
682 SVL M
2265
720
1540
1280
1460
7100
750 SVL M
2705
920
1610
1130
1700
7600
826 SVL M
2910
920
1610
1130
1700
8000
3000
B
[mm]
64
SV
4000
5000
82
SV
A
[mm]
Rated power P1 in kW
20000
Type
15
2
3
4
5
16
1 Pump wheel
5 Scoop tube
2 Turbine wheel
6 Cooler
3 Shell
7 Oil pump
8 Oil tank
C
[mm]
1614
1305
1050
1614
1305
1180
2046
1656
1360
2046
1656
1560
Type
4000
3000
.
ert
NL
ert
Lv
VN
VN
6S
86
75
500
Lv
SV
00
10
11
50
SV
1000
0S
NL
ver
t.
ver
t.
2000
Rated power P1 in kW
A
[mm]
5000
300
200
100
400
C
600
800
1200
1500
2000
3000
4000
17
Pole wheel
with pick-up
Driven
machine
Motor
Scoop tube
position controller
Driven
machine
Motor
Scoop tube
position controller
Actuator
Speed
measuring
transducer
Actuator
Scoop tube position
set value
420 mA
Scoop tube
position actual
value 420 mA
Scoop tube
position set
value 420 mA
Process controller
Speed
indicator
Process
actual value
420 mA
Process
set value
420 mA
18
Offices worldwide
Our services
Installation, commissioning
Training
Maintenance
Original spare parts
Modernization, retrofits and upgrades
Service contracts
19