Study of a Shock Isolation Satellite Transportation Fixture


Srinivasa Prasad K. S1, Rajeev Chaturvedi2,Shree Niwas Sahu3, A. Sekar4 , K. V. Govinda5
1 Student, Bangalore Institute of Technology, Bangalore, Karnataka, 560 004.
2 Engineer SD, MDMD, ISRO Satellite Centre (ISAC), Bangalore, Karnataka, 560 017.
3 Engineer SG, MDMD, ISAC, Bangalore, Karnataka, 560 017

4 Head, Design and Development Section, MDMD, ISAC, Bangalore, Karnataka, 560 017
5 Deputy Director, ICA, ISAC, Bangalore, Karnataka, 560 017
Presenting authors email: rajeevc@isac.gov.in
Abstract
ISRO satellite centre (ISAC) builds the state of art satellites for communication, remote sensing,
scientific experiments, weather forecasting and interplanetary missions. The satellite assembly consists
of a number of detachable payload/equipment panels that provide housing for sensitive and delicate bus
elements viz. power distribution package, IRU package, TTC package, Solar Array Drive Assembly
(SADA) etc. and payload elements. Often the satellite assembly is transported to other centers for
assembly and integration activities. In-house designed Four Bar Linkage Tilting System (FLTS) is used
for transporting the satellite assembly. The transportation of the satellite assembly by road and air is
always a challenge and requires adequate protection system to counter attack the effects of shock and
vibration. Metallic wire rope isolators are used for isolating the FLTS from the destructive effects of
shock and vibration. These isolators exhibit nonlinear force deflection characteristics in order to absorb
the shock energy. This paper discusses the dynamic behavior of the FLTS with the isolators, when
subjected to shock excitation originating during the transportation environment. The finite element
model as well as an equivalent two degree of freedom model were developed and correlated with each
other. The wire rope isolators were modeled as nonlinear springs in the FE model by using pseudo force
method available in MSC Nastran finite element structural code. Theoretical and numerical results
obtained from FEA were found to be in good agreement with each other.

1. Introduction
The Four bar linkage tilting system (FLTS) is one of the mechanical ground support equipments, which is used for
orienting the satellite at any angle during assembly, integration and testing activities. Apart from assembly,
integration and testing activities, it also serves as a rigid platform for the satellite during the transportation. The
complete FLTS along with the satellite is placed in Satellite Transportation and Storage System (STSS). The FE
model of the FLTS is shown in Figure 1. The structural response of the FLTS along with the satellite to the shock
pulse excitation in the vertical direction (Z Axis as shown in Figure 1) should be properly assessed in order to
determine the clearance space available between the satellite and the top surface of the STSS. Further, proper
assessment of the above mentioned structural response helps in avoiding collision and subsequent damage of the
satellite and its components.
The FLTS along with the satellite is mounted on metallic wire rope isolators. These wire rope isolators possess
properties like low natural frequency, ability to deflect in controlled and repeatable way to absorb the impact
loadings and good damping characteristics, which make them suitable for shock and vibration isolation purposes
[1]. In order to meet the requirements of effective absorption of shock energy, they exhibit nonlinear force
deflection characteristics. In the isolation of steady-state vibration, displacement amplitude is usually small, and
nonlinearity of the isolator tends to be unimportant but in the isolation of shock, nonlinearity tends to be more
important because large deflections prevail. The degree of isolation is substantially affected by the ability of the
isolator to accommodate the required deflection in the case of shock isolation.

Page 1 of 2

Indian Conference on Applied Mechanics (INCAM)


IIT Delhi, 12-15 July 2015

Figure 1. Four bar linkage tilting system

2. General Description
The FE model as well an equivalent two degree of freedom model of the FLTS with the isolators was developed. In
order to mathematically model the nonlinear force deflection characteristics of the wire rope isolator, curve fitting
techniques were used and the cubic polynomial which best fits with the static load deflection data of the isolator
was determined. Figure 2 shows the force deflection characteristics of the isolator used.

Figure 2. Force deflection characteristics of the wire rope isolator


In order to model the nonlinearity of the isolators for the case of shock pulse excitation, an efficient method called
pseudo force method which is available in MSC Nastran[2] is used. In this method, localized nonlinearities are
treated so that they require no additional computer time when compared to a purely linear analysis. In this
method, deviations from linearity are treated as additional applied loads.

3. Summary
A study of dynamic behavior of the FLTS with the isolators, when subjected to shock pulse excitation was made.
Both theoretical and FE methods were used and the results were correlated. They were found to be in good
agreement with each other.