Vous êtes sur la page 1sur 54

RC951-8FE16E1

CONFIGURATION GUIDE
Software version: rc9518fe16e1_V1.12.20051215

Raisecom Technology Co., Ltd


December, 2005

Raisecom Technology Co., Ltd

CONTENTS
1

PREFACE.......................................................................................................................................1
1.1

AUDIENCE ................................................................................................................................1

1.2

STRUCTURE OF THIS DOCUMENT ..............................................................................................1

1.3

DEFINITIONS .............................................................................................................................1

1.4

REFERENCES .............................................................................................................................1

ABSTRACT....................................................................................................................................1

USING COMMAND-LINE INTERFACE.....................................................................................2

3.1

REQUIREMENTS OF SOFTWARE AND HARDWARE .......................................................................2

3.2

GETTING HELP ..........................................................................................................................2

3.3

USE HISTORY COMMANDS .........................................................................................................2

3.4

EDITING PROPERTIES.................................................................................................................2

3.5

MODES OF COMMAND-LINE ......................................................................................................3

CONFIGURING SYSTEM COMMANDS ...................................................................................4


4.1

BASIC SYSTEM COMMANDS AND CONFIGURATION ....................................................................4

4.2

MANAGING CONFIGURATION FILES AND STARTUP FILES ............................................................4

1Configuration files....................................................................................................................4
2Startup file.................................................................................................................................5
4.3
5

RC951 CENTRAL OFFICE BASIC CONFIGURATION..........................................................5


5.1

RC951 CENTRAL OFFICE E1 INTERFACE CONFIGURATION .......................................................5

5.1.1

RC951 Central Office E1 Interface Configuration ....................................................5

5.1.2

RC951 Central Office E1 Interface Configuration List.............................................6

5.1.3

Introduction of Configuration .......................................................................................6

5.1.4

Monitoring and maintenance.......................................................................................8

5.2

USER MANAGEMENT .................................................................................................................5

RC951 CENTRAL OFFICE ETHERNET INTERFACE CONFIGURATION ...........................................9

5.2.1

RC951 Central Office Ethernet Interface Configuration..........................................9

5.2.2

RC951 Central Office Ethernet Interface Configuration List...................................9

5.2.3

Introduction of Configuration .......................................................................................9

5.2.4

Monitoring and Maintenance..................................................................................... 11

RC952-FEE1 BASIC CONFIGURATION ................................................................................12


6.1

RC952-FEE1 BASIC CONFIGURATION ....................................................................................12

6.1.1

RC952-FEE1 Basic Configuration............................................................................12

6.1.2

RC952-FEE1 Basic Configuration List ....................................................................12

6.1.3

Introduction of Configuration .....................................................................................12

6.1.4

Monitoring and maintenance.....................................................................................13

6.2

RC952-FEE1 CENTRAL OFFICE E1 INTERFACE CONFIGURATION ...........................................13

6.2.1

RC952-FEE1 E1 Interface General Description.....................................................13

6.2.2

RC952-FEE1 E1 Interface Configuration List.........................................................13

Version 1

Preface 2

Raisecom Technology Co., Ltd

6.2.3

Introduction of Configuration .....................................................................................13

6.2.4

Monitoring and Maintenance.....................................................................................14

6.3

RC952-FEE1 ETHERNET INTERFACE CONFIGURATION ...........................................................15

6.3.1

RC952-FEE1 Ethernet Interface General Description ..........................................15

6.3.2

RC952-FEE1 Ethernet Interface Configuration List...............................................15

6.3.3

Introduction of Configuration .....................................................................................15

6.3.4

Monitoring and Maintenance.....................................................................................17

RC952-FXE1 BASIC CONFIGURATION ................................................................................18


7.1

RC952-FXE1 BASIC CONFIGURATION ...................................................................................18

7.1.1

RC952-FXE1 Equipment Basic Configuration........................................................18

7.1.2

RC952-FXE1 Equipment Basic Configuration List ................................................18

7.1.3

Introduction of Configuration .....................................................................................18

7.1.4

Monitoring and Maintenance.....................................................................................18

7.2

RC952-FXE1 E1 INTERFACE CONFIGURATION.......................................................................19

7.2.1

RC952-FXE1 Equipment E1 Interface Configuration ............................................19

7.2.2

RC952-FXE1 Equipment E1 Interface Configuration List.....................................19

7.2.3

Introduction of Configuration .....................................................................................19

7.2.4

Monitoring and Maintenance.....................................................................................20

7.3

RC952-FXE1 ETHERNET INTERFACE CONFIGURATION ..........................................................20

7.3.1

RC952-FXE1 Equipment Ethernet Interface Configuration..................................20

7.3.2

RC952-FXE1 Equipment Ethernet Interface Configuration List...........................20

7.3.3

Introduction of Configuration .....................................................................................21

7.3.4

Monitoring and Maintenance.....................................................................................21

RC501 CONFIGURATION.........................................................................................................21
8.1

RC501 BASIC CONFIGURATION ..............................................................................................21

8.1.1

RC501 Equipment Basic Configuration...................................................................22

8.1.2

RC501 Equipment Basic Configuration List............................................................22

8.1.3

Introduction of Configuration .....................................................................................22

8.1.4

Monitoring and Maintenance.....................................................................................24

RC601 CONFIGURATION.........................................................................................................24
9.1

RC601 BASIC CONFIGURATION ..............................................................................................24

9.1.1

RC601 Equipment Basic Configuration...................................................................24

9.1.2

RC501 Equipment Basic Configuration List............................................................24

9.1.3

Introduction of Configuration .....................................................................................25

9.1.4

Monitoring and Maintenance.....................................................................................26

10

RC511 CONFIGURATION.....................................................................................................26

10.1

11

RC511 BASIC CONFIGURATION ..............................................................................................26

10.1.1

RC511 Equipment Basic Configuration ...................................................................26

10.1.2

RC511 Equipment Basic Configuration List............................................................27

10.1.3

Introduction of Configuration .....................................................................................27

10.1.4

Monitoring and Maintenance.....................................................................................29

RC511-4FE CONFIGURATION ............................................................................................29

Version 1

Preface 3

Raisecom Technology Co., Ltd

11.1

RC511-4FE BASIC CONFIGURATION ......................................................................................29

11.1.1

RC511-4FE Equipment Basic Configuration...........................................................30

11.1.2

RC511-4FE Equipment Basic Configuration List ...................................................30

11.1.3

Introduction of Configuration .....................................................................................30

11.1.4

Monitoring and Maintenance.....................................................................................31

11.2

RC511-4FE ETHERNET INTERFACE CONFIGURATION .............................................................31

11.2.1

RC511-4FE Ethernet Interface Basic Configuration ..............................................31

11.2.2

RC511-4FE Ethernet Interface Configuration List..................................................31

11.2.3

Introduction of Configuration .....................................................................................32

11.2.4

Monitoring and Maintenance.....................................................................................33

12

MAP CONFIGURATION ........................................................................................................33

12.1

MAP GENERAL DESCRIPTION ..................................................................................................34

12.2

MAP CONFIGURATION LIST .....................................................................................................34

12.3

INTRODUCTION OF CONFIGURATION .......................................................................................34

12.3.1

Create map (add map NAME Ethernet {1-8} [e1 {1-16}]) .....................................34

12.3.2

Modify map (modify map NAME Ethernet {1-8} [e1 {1-16}]).................................34

12.3.3

Delete map (no map NAME) .....................................................................................34

12.4
13

INTRODUCTION OF CONFIGURATION .......................................................................................35


NETWORK MANAGEMENT INTERFACE CONFIGURATION .......................................35

13.1

NETWORK MANAGEMENT INTERFACE GENERAL DESCRIPTION ..............................................35

13.2

NETWORK MANAGEMENT INTERFACE CONFIGURATION LIST .................................................35

13.3

INTRODUCTION OF CONFIGURATION .......................................................................................35

13.3.1

Configure a port as management port (mgmt-port <1-8>)....................................35

13.3.2

Shut down management port (no mgmt-port <1-8>) .............................................35

13.4
14

MONITORING AND MAINTENANCE ..........................................................................................36


SNMP CONFIGURATION......................................................................................................36

14.1

SNMP GENERAL DESCRIPTION ..............................................................................................36

14.2

SNMP CONFIGURATION LIST .................................................................................................36

14.3

INTRODUCTION OF CONFIGURATION .......................................................................................37

14.3.1

Configure community name ......................................................................................37

14.3.2

Enable or disable trap ................................................................................................37

14.3.3

Configure trap manager and port number...............................................................37

14.3.4

Delete trap manager...................................................................................................38

14.3.5

Erase all trap configuration........................................................................................38

14.3.6

Configure contact information ...................................................................................38

14.3.7

Configure location information ..................................................................................38

14.3.8

Configure name information......................................................................................38

14.3.9

Configure description information.............................................................................39

14.4
15

MONITORING AND MAINTENANCE ..........................................................................................39


EXAMPLES OF CONFIGURING RC951-8FE16E1 AND RC952 ...................................40

Version 1

Preface 4

Raisecom Technology Co., Ltd

1 Preface
1.1

Audience

This guide is for experienced network administrators who are


responsible for configuring and maintaining RC951-8FE16E1. And it
describes the device function as well as how to configure.
1.2

Structure of this Document


There are mainly 7 chapters in this guide:
Chapter 2: DESCRIPTION
Describe the main features of RC951-8FE16E1
Chapter 3: HOW TO USE COMMAND-LINE
Describe how to configure RC951-8FE16E1 through command-line and
application feathers.
Chapter 4: CONFIGURING SYSTEM COMMANDS
Describe system command function of RC951-8FE16E1 and how to configure.
Chapter 5: CONFIGURING NETWORK PROTOCOLS
Describe how to configure RC951-8FE16E1 in central office.
Chapter 6: CONFIGURING ETHERNET INTERFACES
Describe Ethernet interface function of RC951-8FE16E1 and how to configure
Chapter 7: CONFIGURING E1 INTERFACES
Describe E1 interface function of RC951-8FE16E1 and how to configure
Chapter 8: CONFIGURING CROSSCONNECT
Describe crossconnect function of RC951-8FE16E1 and how to configure
Chapter 9: NETWORKING
Describe how to establish network by RC951-8FE16E1
Chapter 10: CONFIGURATION EXAMPLES
Describe examples of how to configure RC951-8FE16E1.

1.3 Definitions
FEFast Ethernet
GEGigabit Ethernet
1.4

References
RC951-8FE16E1 device commands notebook

2 Abstract
RC951-8FE16E1 is Ethernet over multiple E1 aggregation device. You can
access RC951-8FE16E1 via the devices serial port RS232 or network
management interface: Telnet, and it also provides standard SNMP
management interface and can be field upgraded.

Page 1 of 54

Raisecom Technology Co., Ltd

3 Using Command-line Interface


3.1

Requirements of software and hardware

Operation environment of hardware: platform of RC951-8FE16E1


Computer serial interface;
Operation environment of software: WIN98/WIN2000/WINDOWS XP
3.2

Getting help

command
help

Function description
Getting a brief description from help
system
abbreviated-command-entry?
Obtaining a list of commands that begin
with a
particular character sequence
abbreviated-command-entry
For example:
RC951-8FE16E1#en ?
english
enable
abbreviated-command-entry<Tab> Supplementing an unfinished command.
For example:
RC951-8FE16E1#show mac<TAB>
RC951-8FE16E1#show
mac-address-table
?
Listing all the commands in this mode
For example:
RC951-8FE16E1#
command?
Listing all the key words, options and
brief help information of a command.
RC951-8FE16E1#show ?
3.3

Use history commands

There are 20 history commands in the memory of the device system by default.
User can configure the number of history commands that system can save by
the command-line:
raisecom# terminal history

<0-20>

Use history to show commands that has been entered.


3.4 Editing properties

up arrow:
down arrow:
left arrow:
right arrow:
backspace:

last entered command


next entered command
move a character left
move a character right
delete a character in front of the cursor
Page 2 of 54

Raisecom Technology Co., Ltd

Ctrl+d:
Ctrl+a:
Ctrl+e:
Ctrl+k:
Ctrl+w:
Ctrl+u:
Ctrl+z:

3.5

delete a character at the cursor


move the cursor to the beginning of the command line
move the cursor to the end of the command line
delete all the characters on the right side the cursor
delete all the characters on the left side of the cursor
delete the row all
exit from other modes to privileged mode

Modes of command-line

Mode
Privileged user mode

Under this mode, using enable enters to this


modeusing disable exits this mode

Config mode

Under privileged user mode, using config


enters to config mode, using exit returns to
privileged user mode

Snmp mode

Under config mode, using snmp enters to


snmp mode, using exit returns config mode

Interface E1 mode

Under config mode, using interface e1


enters to interface e1 mode, using exit
returns to config mode.

Interface Ethernet mode

Under config mode, using interface Ethernet


enters to interface Ethernet modeusing exit
returns to config mode

Interface convert mode

Under
config
mode,
using
remote
interfaceconvert
enters
to
remote
interfaceconvert mode (accrding to the type of
remote device, enter rc952fee1 or rc952fxe1
mode), using exit returns config mode.

RC952-FEE1 mode

Under config mode, using remote rc952fee1


enters to rc952fee1 mode, using exit returns
config mode.

Interface Ethernet mode under RC952-FEE1

Under Rc952fee1 mode, using interface


Ethernet enters to interface Ethernet mode of
Rc952fee1, using exit returns to Rc952fee1
mode.

Interface E1 under RC952-FEE1

Under Rc952fee1 mode, using interface e1


enters to interface e1mode of Rc952fee1,
using exit returns to Rc952fee1 mode.

RC952-FXE1 mode

Under config mode, using remote Rc952fxe1


enters to Rc952fxe1 mode, using exit
returns to config mode.

Page 3 of 54

Raisecom Technology Co., Ltd

Interface E1 mode under RC952-FXE1

Under Rc952fxe1 mode, using interface e1


enters to interface e1 mode of Rc952fxe1,
using exit returns to Rc952fxe1 mode.

interface FX-Ethernet mode under RC952-FXE1

Under Rc952fxe1 mode, using interface


fx-ethernet enters to interface fx-ethernet
mode of Rc952fxe1, using exit returns to
rc952fxe1 mode.

MC mode

Under config mode, using remote mc enters


remote mc mode (according to the type of
remote
media
converters,
enter
to
rc501,rc511,rc5114fe or rc601 mode), using
exit returns to config mode.

RC501 mode

Under config mode, using remote rc501


enters to rc501 mode, using exit returns to
config mode.

RC511 mode

Under config mode, using remote rc511


enters to rc511 mode, using exit returns to
config mode.

RC511-4FE mode

Under config mode, using remote rc5114fe


enter to rc5114fe mode, using exit return to
config mode

Interface Ethernet mode under RC511-4FE

Under rc5114fe mode, using interface


Ethernet enters to interface Ethernet mode,
using exit returns to rc5114fe mode.

RC601 mode

Under config mode, using remote rc601


enters to rc601 mode, using exit returns to
config mode

4 Configuring system commands


Basic system configuration and user management.
4.1

Basic system commands and configuration

chinese
english
clear
list
settime

4.2

show help information of the command in Chinese


show help information of the command in English
clear the information on the screen
show the list of all the commands in one mode
change the system time

Managing configuration files and startup files

1Configuration files

Page 4 of 54

Raisecom Technology Co., Ltd

The present reserved configuration file name is startup_config.conf by


default.
Use write command to write the configuration file into the flash file
system, when the system resets next time, the reserved configuration
information will be configured again.
Use erase command to delete that file
2Startup file

Same as program system file, and the file name is: RC951-8FE16E1.Z;

The program file can be uploaded to the server by commands upload


and download through the FTP protocol or TFTP protocol, or
downloaded to system.
Use show version to check the version information.
4.3

User management

The system has a default username raisecom and the password


raisecom;
Add a new user, the steps are as follows:
steps Command
Description
1
user
USERNAME z USERNAME user name
password
z Password password;
z PASSWORD password
information;
2
z USERNAME user name;
user USERNAME
privilege <1-15>
z Privilege key word for privilege
<1-15> user privilege
3
Save the configuration information
write
4
Show the user information
show user

5 RC951 Central Office Basic Configuration


5.1

RC951 Central Office E1 Interface Configuration


This chapter introduces how to configure the E1 interfaces of RC951 equipment at
Central Office and includes the following sections:
RC951 Central Office general description;
RC951 Central Office configuration list;
Introduction of configuration;
Monitoring and maintenance.

5.1.1 RC951 Central Office E1 Interface Configuration


Configure RC951 Central Office E1 interface functions.

Page 5 of 54

Raisecom Technology Co., Ltd

5.1.2 RC951 Central Office E1 Interface Configuration List


z Configure the clock mode (master | slave)
z Configure E1 interface to framed transmission (framed)
z Configure E1 interface to unframed transmission (unframed)
z Configure E1 interface data rate (timeslot {1-31})
z Configure E1 interface CRC (CRC-auto (enable | disable)
z Configure remote E1 interface loop-back ([no] remote-e1-loop-back)
z Configure E1 interface loop-back ([no] loop-back)
z Configure E1 interface bit error test (BERT (enable | disable))
5.1.3 Introduction of Configuration
5.1.3.1 Configure the clock mode (master | slave)
Step

Command

Description

1
2

config
Interface e1 <1-16>

clock-mode (master | slave)

Enter global configuration exec


Enter RC951 Central Office E1
configuration exec
Configure clock mode

show interface

Display the configuration

raisecom#config
raisecom(config)# interface e1 1
raisecom(config-E1/1)# clock-mode master
raisecom(config-E1/1)#show interface
5.1.3.2

Configure E1 interface to framed transmission (framed)

Step

Command

Description

1
2

config
Interface e1 <1-16>

frame

Enter global configuration exec


Enter RC951 Central Office E1
configuration exec
Configure E1 interface to framed
transmission

show interface

Display the configuration

raisecom#config
raisecom(config)# interface e1 1
raisecom(config-E1/1)# frame
raisecom(config-E1/1)#show interface
5.1.3.3

Configure E1 interface to unframed transmission (unframed)

Step

Command

Description

1
2

config
Interface e1 <1-16>

unframe

Enter global configuration exec


Enter RC951 Central Office E1
configuration exec
Configure
E1
interface
to

Page 6 of 54

Raisecom Technology Co., Ltd

unframed transmission
4

show interface

Display the configuration

raisecom#config
raisecom(config)# interface e1 1
raisecom(config-E1/1)# unframe
raisecom(config-E1/1)#show interface
5.1.3.4

Configure E1 interface data rate (timeslot {1-31})

Step

Command

Description

1
2

config
Interface e1 <1-16>

timeslot {1-31}

Enter global configuration exec


Enter RC951 Central Office E1
configuration exec
Configure E1 interface data rate

show interface

Display the configuration

raisecom#config
raisecom(config)# interface e1 1
raisecom(config-E1/1)# timeslot 1-5
raisecom(config-E1/1)#show interface
5.1.3.5

Configure E1 interface CRC (CRC-auto (enable | disable)

Step

Command

Description

1
2

config
Interface e1 <1-16>

crc-auto (enable | disable)

Enter global configuration exec


Enter RC951 Central Office E1
configuration exec
Configure E1 interface CRC

show interface

Display the configuration

raisecom#config
raisecom(config)# interface e1 1
raisecom(config-E1/1)# crc enable
raisecom(config-E1/1)#show interface
5.1.3.6

Configure remote E1 interface loop-back ([no] remote-e1-loopback)

Step

Command

Description

1
2

config
Interface e1 <1-16>

[no] remote-e1-loopback

Enter global configuration exec


Enter RC951 Central Office E1
configuration exec
Configure remote E1 loop-back

show interface

Display the configuration

raisecom#config
raisecom(config)# interface e1 1
Page 7 of 54

Raisecom Technology Co., Ltd

raisecom(config-E1/1)# remote-e1-loopback
raisecom(config-E1/1)#show interface
5.1.3.7

Configure E1 interface loop-back ([no] loop-back)

Step

Command

Description

1
2

config
Interface e1 <1-16>

[no] loopback

Enter global configuration exec


Enter RC951 Central Office E1
configuration exec
Configure E1 loop-back

show interface

Display the configuration

raisecom#config
raisecom(config)# interface e1 1
raisecom(config-E1/1)# loopback
raisecom(config-E1/1)#show interface
5.1.3.8

Configure E1 interface bit error test (BERT (enable | disable))

Step

Command

Description

1
2

config
Interface e1 <1-16>

bert (enable | disable)

Enter global configuration exec


Enter RC951 Central Office E1
configuration exec
Configure E1 interface BERT

show interface

Display the configuration

raisecom#config
raisecom(config)# interface e1 1
raisecom(config-E1/1)# bert enable
raisecom(config-E1/1)#show interface
5.1.4 Monitoring and maintenance
Under Interface E1 exec, user can use show interface command to view E1 interface
current status and configuration.
raisecom(config-E1/1)#show interface
E1:1
Basic Info:
Clock Mode:slave
Frame Mode:unframed
Frame timeslot:n/a
Frame CRC State:enable
Frame CRC Autonegotiation:disable
Maintenance:
Loop Back(config):enable
Loop Back(Result):Success
Page 8 of 54

Raisecom Technology Co., Ltd

Lineloop(config):disable
Bert:enable
Packet Statistics:
TX Packet Number:16777215
RX Packet Number:16777215
RX Error Packet Number:255
Performance Statistics:
Error Second:15
Serial Error Second:15
Bit Error Rate: thousandth
Fault State:
LOS:Failure
AIS:Failure
LOF:Failure
CRC:Failure
5.2

RC951 Central Office Ethernet Interface Configuration


This chapter introduces how to configure Ethernet interfaces of RC951 equipment at
Central Office and includes the following sections:
RC951 Central Office Ethernet interfaces general description;
RC951 Central Office Ethernet interfaces configuration list;
Introduction of configuration;
Monitoring and maintenance.

5.2.1 RC951 Central Office Ethernet Interface Configuration


Configure RC951 Central Office Ethernet interface functions.
5.2.2 RC951 Central Office Ethernet Interface Configuration List
z Open Ethernet interface (no shutdown)
z Shut down Ethernet interface (shutdown)
z Configure speed auto-negotiation (speed (auto))
z Configure speed and duplex mode (speed (10 | 100) duplex (full | half))
z Configure flow control (flow-control (on | off))
z Reset statistic counter (reset-statistics)
5.2.3 Introduction of Configuration
5.2.3.1 Open Ethernet interface (no shutdown)
Step

Command

Description

1
2

config
Interface ethernet <1-8>

no shutdown

Enter global configuration exec


Enter RC951 Central Office
Ethernet configuration exec
Open Ethernet interface
Page 9 of 54

Raisecom Technology Co., Ltd

show interface

Display the configuration

raisecom#config
raisecom(config)# interface eth 1
raisecom(config-ethernet/1)# no shutdown
raisecom(config- eth-1)#show interface
5.2.3.2

Shut down Ethernet interface (shutdown)

Step

Command

Description

1
2

config
Interface ethernet <1-8>

shutdown

Enter global configuration exec


Enter RC951 Central Office
Ethernet configuration exec
Shut down Ethernet interface

show interface

Display the configuration

raisecom#config
raisecom(config)# interface ethernet 1
raisecom(config-ethernet/1)# shutdown
raisecom(config-ethernet/1)#show interface
5.2.3.3

Configure speed auto-negotiation (speed (auto))

Step

Command

Description

1
2

config
Interface ethernet <1-8>

speed auto

Enter global configuration exec


Enter RC951 Central Office
Ethernet configuration exec
Configure Ethernet interface to
auto-negotiation

show interface

Display the configuration

raisecom#config
raisecom(config)# interface eth 1
raisecom(config-ethernet/1)# speed auto
raisecom(config-ethernet/1)#show interface
5.2.3.4

Configure speed and duplex mode (speed (10 | 100) duplex (full | half))

Step

Command

Description

1
2

config
Interface ethernet <1-8>

Speed (100|10) duplex (full | half)

Enter global configuration exec


Enter RC951 Central Office
Ethernet configuration exec
Configure Ethernet speed and
duplex mode

show interface

Display the configuration

raisecom#config

Page 10 of 54

Raisecom Technology Co., Ltd

raisecom(config)# interface eth 1


raisecom(config-ethernet/1)# speed 100 duplex half
raisecom(config-ethernet/1)#show interface
5.2.3.5

Configure flow control (flow-control (on | off))

Step

Command

Description

1
2

config
Interface ethernet <1-8>

flow-control (on | off)

Enter global configuration exec


Enter RC951 Central Office
Ethernet configuration exec
Configure the flow control mode

show interface

Display the configuration

raisecom#config
raisecom(config)# interface eth 1
raisecom(config-ethernet/1)# flow-control on
raisecom(config-ethernet/1)#show interface
5.2.3.6

Reset statistic counter (reset-statistics)

Step

Command

Description

1
2

config
Interface ethernet <1-8>

reset-statistics

Enter global configuration exec


Enter RC951 Central Office
Ethernet configuration exec
Reset the statistic counter

show interface

Display the configuration

raisecom#config
raisecom(config)# interface eth 1
raisecom(config-ethernet/1)# reset-statistics
raisecom(config-ethernet/1)#show interface
5.2.4 Monitoring and Maintenance
Under interface Ethernet exec, user can use show interface command to view Ethernet
interfaces current status and configuration.
raisecom(config-ethernet/1)#show interface
Port 1:
Basic Info:
Linkstatus:down
speed-duplex: 10M-half
Manage port:On
Config Info:
Port Switch:On
Auto negotiate:enable
auto-MDIX:enable
flowcontrol:ON
Page 11 of 54

Raisecom Technology Co., Ltd

Performance Statistics:
TX Packet Number:0
TX Bytes Number:0
RX Packet Number:0
RX Bytes Number:0
RX Lost Packet Number:0
Collision Number:0

6 RC952-FEE1 Basic Configuration


6.1 RC952-FEE1 Basic Configuration
This chapter introduces how to configure RC951 equipment to work with RC952-FEE1,
and includes the following sections.
z RC952-FEE1 general description
z RC952-FEE1 configuration list
z Introduction of configuration
z Monitoring and maintenance
6.1.1 RC952-FEE1 Basic Configuration
Configure RC952-FEE1 functions.
6.1.2 RC952-FEE1 Basic Configuration List
z Configure fault propagation function (fault-pass (enable | disable))
z Reset the remote equipment (reset)
6.1.3 Introduction of Configuration
6.1.3.1 Configure fault propagation function
Step

Command

Description

1
2

config
Remote rc952fee1 <1-16>

fault-pass (enable | disable)

Enter global configuration exec


Enter RC951 Central Office E1
configuration exec
Configuration fault propagation

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc952fee1 1
raisecom(config-RC952FEE1/1)# fault-pass enable
raisecom(config-RC952FEE1/1)#show interface
6.1.3.2

Reset the remote equipment

Step

Command

Description

1
2

config
Remote rc952fee1 <1-16>

Enter global configuration exec


Enter RC951 Central Office E1
Page 12 of 54

Raisecom Technology Co., Ltd

reset

configuration exec
Reset the remote equipment

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc952fee1 1
raisecom(config-RC952FEE1/1)# reset
raisecom(config-RC952FEE1/1)#show interface
6.1.4 Monitoring and maintenance
Under remote RC952-FEE1 exec, user can use show device command to view
RC952-FEE1 current status and configuration.
raisecom(config-RC952FEE1/1)#show device
Device 1:RC952FEE1
Basic Running Info:
Management Operation Status:Slave
version:A.0-0.0-E0
Optical Module Type:noexist
Fault-pass:disable
Basic Config Info:
Fault-pass:disable
6.2 RC952-FEE1 Central Office E1 Interface Configuration
This chapter introduced how to configure E1 interface of RC952-FEE1, and includes the
following sections.
z RC952-FEE1 E1 interface general description
z RC952-FEE1 E1 interface configuration list
z Introduction of configuration
z Monitoring and maintenance
6.2.1 RC952-FEE1 E1 Interface General Description
Configure RC952-FEE1 E1 interface functions.
6.2.2 RC952-FEE1 E1 Interface Configuration List
z Configure clock mode (clock-mode (master | slave))
z Configure E1 interface CRC (CRC-auto (enable | disable))
6.2.3 Introduction of Configuration
6.2.3.1 Configure clock mode (clock-mode (master | slave))
Step

Command

Description

1
2

config
Remote rc952fee1 <1-16>

Interface e1

Enter global configuration exec


Enter RC952-FEE1 equipment
exec
Enter RC952-FEE1 E1 interface
Page 13 of 54

Raisecom Technology Co., Ltd

clock-mode(master | slave)

configuration exec
Configure clock mode

show interface

Display the configuration

raisecom#config
raisecom(config)# remote rc952fee1 1
raisecom(config-RC952FEE1/1)# clock-mode master
raisecom(config- RC952FEE1/1-E1)#show interface
6.2.3.2

Configure E1 interface CRC (CRC-auto (enable | disable))

Step

Command

Description

1
2

config
Remote rc952fee1 <1-16>

Interface e1

crc-auto (enable | disable)

Enter global configuration exec


Enter RC952-FEE1 equipment
exec
Enter RC952-FEE1 E1 interface
configuration exec
Configure CRC

show interface

Display the configuration

raisecom#config
raisecom(config)# remote rc952fee1 1
raisecom(config-RC952FEE1/1)#crc enable
raisecom(config- RC952FEE1/1-E1)#show interface
6.2.4 Monitoring and Maintenance
Under interface E1 exec in RC952-FEE1, user can use show interface command to view
E1 interface current status and configuration.
Raisecom(config-RC952FEE1/1-E1)# show interface
E1:1
Basic Running Info:
Clock Mode:master
Frame Mode:unframed
Frame timeslot:n/a
Frame CRC State:disable
Frame CRC Autonegotiation:disable
Flow control:OFF
Maintenance:
Loopback(config):disable
remote-e1-loopback(config):disable
Bert:disable
Packet Statistics:
TX Packet Number:183
Page 14 of 54

Raisecom Technology Co., Ltd

RX Packet Number:0
RX Error Packet Number:0
Performance Statistics:
Error Second:0
Serial Error Second:0
Bit Error Rate: Zero
Fault State:
LOS:Failure
AIS:Normal
LOF:Normal
CRC:Normal
6.3 RC952-FEE1 Ethernet Interface Configuration
This chapter introduces how to configure Ethernet interface of RC952-FEE1, and includes
the following sections.
z RC952-FEE1 Ethernet interface general description
z RC952-FEE1 Ethernet interface configuration list
z Introduction of configuration
z Monitoring and maintenance
6.3.1 RC952-FEE1 Ethernet Interface General Description
Configure RC952-FEE1 Ethernet interface functions.
6.3.2 RC952-FEE1 Ethernet Interface Configuration List
z Open Ethernet interface (no shutdown)
z Shut down Ethernet interface (shutdown)
z Configure Ethernet speed auto-negotiation (speed auto)
z Configure Ethernet speed and duplex mode (speed (10 | 100) duplex (full | half))
z Configure flow control (flow-control (on | off))
6.3.3 Introduction of Configuration
6.3.3.1 Open Ethernet interface
Step

Command

Description

1
2

config
Remote rc952fee1 <1-16>

Interface eth

no shutdown

Enter global configuration exec


Enter RC952-FEE1 equipment
exec
Enter
RC952-FEE1
Ethernet
configuration exec
Open Ethernet interface

show interface

Display the configuration

raisecom#config
raisecom(config)# remote rc952fee1
Page 15 of 54

Raisecom Technology Co., Ltd

raisecom(config-RC952FEE1/1)# interface eth 1


raisecom(config-RC952FEE1/1-eth)# no shutdown
raisecom(config-RC952FEE1/1-eth)#show interface
6.3.3.2

Shut down Ethernet interface

Step

Command

Description

1
2

config
Remote rc952fee1 <1-16>

Interface eth

shutdown

Enter global configuration exec


Enter RC952-FEE1 equipment
exec
Enter
RC952-FEE1
Ethernet
configuration exec
Shut down Ethernet interface

show interface

Display the configuration

raisecom#config
raisecom(config)# remote rc952fee1
raisecom(config-RC952FEE1/1)# interface eth 1
raisecom(config-RC952FEE1/1-eth)#shutdown
raisecom(config-RC952FEE1/1-eth)#show interface
6.3.3.3

Configure Ethernet speed auto-negotiation (speed auto)

Step

Command

Description

1
2

config
Remote rc952fee1 <1-16>

Interface ethernet

speed auto

Enter global configuration exec


Enter RC952-FEE1 equipment
exec
Enter
RC952-FEE1
Ethernet
configuration exec
Configure
Ethernet
to
auto-negotiation

show interface

Display the configuration

raisecom#config
raisecom(config)# remote rc952fee1
raisecom(config-RC952FEE1/1)# interface ethernet 1
raisecom(config-RC952FEE1/1-eth)#speed auto
raisecom(config-RC952FEE1/1-eth)#show interface
6.3.3.4

Configure Ethernet speed and duplex mode (speed (10 | 100) duplex (full | half))

Step

Command

Description

1
2

config
Remote rc952fee1 <1-16>

Interface ethernet

Enter global configuration exec


Enter RC952-FEE1 equipment
exec
Enter
RC952-FEE1
Ethernet
configuration exec

Page 16 of 54

Raisecom Technology Co., Ltd

Speed (100|10) duplex (full | half))

Configure
Ethernet
interface
speed and duplex mode

show interface

Display the configuration

raisecom#config
raisecom(config)# remote rc952fee1
raisecom(config-RC952FEE1/1)# interface ethernet 1
raisecom(config-RC952FEE1/1-eth)#speed 10 duplex half
raisecom(config-RC952FEE1/1-eth)#show interface
6.3.3.5

Configure flow control (flow-control (on | off))

Step

Command

Description

1
2

config
Remote rc952fee1 <1-16>

Interface ethernet

flow-control (on | off)

Enter global configuration exec


Enter RC952-FEE1 equipment
exec
Enter
RC952-FEE1
Ethernet
configuration exec
Configure flow control mode

show interface

Display the configuration

raisecom#config
raisecom(config)# remote rc952fee1
raisecom(config-RC952FEE1/1)# interface ethernet 1
raisecom(config-RC952FEE1/1-eth)# flow-control on
raisecom(config-RC952FEE1/1-eth)#show interface
6.3.4 Monitoring and Maintenance
Under interface eth exec in RC952-FEE1, user can use show interface command to view
Ethernet interface current status and configuration.
raisecom(config-RC952FEE1/1-eth)#show interface
Port 1:RC952FEE1
Basic Info:
Port:Disable
Linkstatus:Down
Autonegotiation:disable
speed-duplex: 10M-half
flowcontrol:OFF
Config Info:
Port:Disable
Speed:10M
Duplex:half
flowcontrol:OFF
Ethernet Performance Statistics:
Page 17 of 54

Raisecom Technology Co., Ltd

TX Packet Number:0
RX Packet Number:0
RX Error Packet Number:0

7 RC952-FXE1 Basic Configuration


7.1 RC952-FXE1 Basic Configuration
This chapter introduces how to configure RC951 equipment to work with RC952-FXE1,
and includes the following sections.
z RC952-FXE1 general description
z RC952-FXE1 configuration list
z Introduction of configuration
z Monitoring and maintenance
7.1.1 RC952-FXE1 Equipment Basic Configuration
Configure RC952-FXE1 functions.
7.1.2 RC952-FXE1 Equipment Basic Configuration List
z Reset remote equipment (reset)
7.1.3 Introduction of Configuration
7.1.3.1 Reset remote equipment (reset)
Step

Command

Description

1
2

config
Remote rc952fxe1 <1-16>

reset

Enter global configuration exec


Enter RC952-FXE1 configuration
exec
Reset remote equipment

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc952fxe1 1
raisecom(config-RC952FXE1/1)# reset
raisecom(config-RC952FXE1/1)#show interface
7.1.4 Monitoring and Maintenance
Under remote RC952-FXE1 exec, user can use show device command to view
RC952-FXE1 current status and configuration.
raisecom(config-RC952FXE1/1)#show device
Device 1:RC952FXE1
Basic Running Info:
Management Operation Status:Slave
version:A.0-0.0-E0
Optical Module Type:noexist

Page 18 of 54

Raisecom Technology Co., Ltd

7.2 RC952-FXE1 E1 Interface Configuration


This chapter introduces how to configure RC951 equipment to work with RC952-FXE1 E1
interface, and includes the following sections.
z RC952-FXE1 general description
z RC952-FXE1 configuration list
z Introduction of configuration
z Monitoring and maintenance
7.2.1 RC952-FXE1 Equipment E1 Interface Configuration
Configure RC952-FXE1 equipment E1 interface functions.
7.2.2 RC952-FXE1 Equipment E1 Interface Configuration List
z Configure E1 interface clock mode (clock-mode (master | slave))
z Configure E1 interface CRC (crc-auto (enable | disable))
7.2.3 Introduction of Configuration
7.2.3.1 Configure E1 interface clock mode (clock-mode (master | slave))
Step

Command

Description

1
2

config
Remote rc952fxe1 <1-16>

Interface e1

clock-mode(master | slave)

Enter global configuration exec


Enter RC952-FXE1 equipment
exec
Enter RC952-FXE1 E1 interface
configuration exec
Configure clock mode

show interface

Display the configuration

raisecom#config
raisecom(config)# remote rc952fxe1 1
raisecom(config-RC952FXE1/1)# interface e1
raisecom(config-RC952FXE1/1-E1)# clock-mode master
raisecom(config-RC952FXE1/1-E1)#show interface
7.2.3.2

Configure E1 interface CRC (crc-auto (enable | disable))

Step

Command

Description

1
2

config
Remote rc952fxe1 <1-16>

Interface e1

crc-auto (enable | disable)

Enter global configuration exec


Enter RC952-FXE1 equipment
exec
Enter RC952-FXE1 E1 interface
configuration exec
Configure CRC

show interface

Display the configuration

raisecom#config
raisecom(config)# remote rc952fxe1 1
raisecom(config-RC952FXE1/1)#interface e1
Page 19 of 54

Raisecom Technology Co., Ltd

raisecom(config- RC952FXE1/1-E1))#crc enable


raisecom(config-RC952FXE1/1-E1)#show interface
7.2.4 Monitoring and Maintenance
Under interface E1 in RC952-FXE1, user can use show interface command to view E1
interface current status and configuration.
RAISECOM(config-RC952FXE1/1-E1)# show interface
Port 1:RC952FXE1
Basic Running Info:
Clock-mode:slave
Frame Mode:framed
Frame timeslot:0
Frame CRC autonegotiation:disable
Frame CRC Check:disable
Basic Config Info:
Clock-mode:slave
Frame Mode:unframed
Frame timeslot:N/A
Frame CRC autonegotiation:disable
Packet Statistics:
TX Packet Number:0
RX Packet Number:0
RX Error Packet Number:0
Fault State:
LOS:Normal
AIS:Normal
LOF:Normal
CRC:Normal
7.3 RC952-FXE1 Ethernet Interface Configuration
This chapter introduces how to configure RC951 equipment to work with RC952-FXE1 E1
interface, and includes the following sections.
z RC952-FXE1 general description
z RC952-FXE1 configuration list
z Introduction of configuration
z Monitoring and maintenance
7.3.1 RC952-FXE1 Equipment Ethernet Interface Configuration
Configure RC952-FXE1 Ethernet interface functions.
7.3.2 RC952-FXE1 Equipment Ethernet Interface Configuration List
z Configure flow control (flow-control (on | off))

Page 20 of 54

Raisecom Technology Co., Ltd

7.3.3 Introduction of Configuration


7.3.3.1 Configure flow control (flow-control (on | off))
Step

Command

Description

1
2

config
Remote rc952fxe1 <1-16>

Interface fx-ethernet

flow-control (on | off)

Enter global configuration exec


Enter RC952-FXE1 equipment
exec
Enter
RC952-FXE1
Ethernet
configuration exec
Configure flow control

show interface

Display the configuration

raisecom#config
raisecom(config)# remote rc952fxe1
raisecom(config-RC952FXE1/1)# interface fx-ethernet
raisecom(config-RC952FXE1/1-eth)# flow-control on
raisecom(config-RC952FXE1/1-eth)#show interface
7.3.4 Monitoring and Maintenance
Under interface eth exec in RC952-FXE1, user can use show interface command to view
Ethernet current status and configuration.
raisecom(config-RC952FXE1/1-eth)#show interface
Port 1:RC952FXE1
Basic Info:
Tx Link:Down
Rx Link:Down
flowcontrol:OFF
Config Info:
flowcontrol:OFF
Ethernet Performance Statistics:
TX Packet Number:0
RX Packet Number:0
RX Error Packet Number:0

8 RC501 Configuration
8.1 RC501 Basic Configuration
This chapter introduces how to configure RC951 equipment to work with RC501, and
includes the following sections.
z RC501 general description
z RC501 configuration list
z Introduction of configuration
Page 21 of 54

Raisecom Technology Co., Ltd

Monitoring and maintenance

8.1.1 RC501 Equipment Basic Configuration


Configure RC501 functions.
8.1.2 RC501 Equipment Basic Configuration List
z Configure fault pass through (fault-pass (enable | disable))
z Remote reset (reset)
z Open the port (no shutdown)
z Shut down the port (shutdown)
z Configure auto-negotiation (speed auto)
z Configure speed and duplex mode (speed (100 | 10) duplex (full | half))
8.1.3 Introduction of Configuration
8.1.3.1 Configure fault pass through (fault-pass (enable | disable))
Step

Command

Description

1
2
3

config
Remote rc501 <1-16>
fault-pass (enable | disable)

Enter global configuration exec


Enter RC501 configuration exec
Configure fault pass through

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc501 1
raisecom(config-RC501/1)# fault-pass enable
raisecom(config-RC501/1)#show interface
8.1.3.2 Remote reset (reset)
Step

Command

Description

1
2
3

config
Remote rc501 <1-16>
reset

Enter global configuration exec


Enter RC501 configuration exec
Reset the remote equipment

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc501 1
raisecom(config-RC501/1)# reset
raisecom(config-RC501/1)#show interface
8.1.3.3 Open the port (no shutdown)
Step

Command

Description

1
2
3

config
Remote rc501 <1-16>
no shutdown

Enter global configuration exec


Enter RC501 configuration exec
Open the port

show interface

Display the configuration

Page 22 of 54

Raisecom Technology Co., Ltd

raisecom#config
raisecom(config)# Remote rc501 1
raisecom(config-RC501/1)# no shutdown
raisecom(config-RC501/1)#show interface
8.1.3.4 Shut down the port (shutdown)
Step

Command

Description

1
2
3

config
Remote rc501 <1-16>
shutdown

Enter global configuration exec


Enter RC501 configuration exec
Shut down the port

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc501 1
raisecom(config-RC501/1)# shutdown
raisecom(config-RC501/1)#show interface
8.1.3.5 Configure auto-negotiation (speed auto)
Step

Command

Description

1
2
3

config
Remote rc501 <1-16>
speed auto

Enter global configuration exec


Enter RC501 configuration exec
Configure auto negotiation

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc501 1
raisecom(config-RC501/1)# speed auto
raisecom(config-RC501/1)#show interface
8.1.3.6 Configure speed and duplex mode (speed (100 | 10) duplex (full | half))
Step

Command

Description

1
2
3

config
Remote rc501 <1-16>
Speed (100|10) duplex (full | half)

Enter global configuration exec


Enter RC501 configuration exec
Configure speed and duplex
mode

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc501 1
raisecom(config-RC501/1)# speed 100 duplex half
raisecom(config-RC501/1)#show interface

Page 23 of 54

Raisecom Technology Co., Ltd

8.1.4 Monitoring and Maintenance


Under RC501 configuration exec, user can use show device command to view RC501
current status and configuration.
Raisecom(config-RC501/1)# show device
Basic Info:
Temperature:0
Optical Module Type:unknown
Voltage High Alarm:Normal
Voltage Low Alarm:Normal
Fx Info:
Rx Link:DOWN
Tx Link:DOWN
SD:Abnormal
TX Power:Normal
Rx Sensibility:Normal
Laser:Normal
TP Running Info:
Linkstatus:DOWN
Port:Disable
Autonegotiation:disable
speed-duplex: 10M-half
Fault-pass:Disable
TP Config Info:
Port:Disable
Speed:10M
Duplex:half
Fault-pass:Disable

9 RC601 Configuration
9.1 RC601 Basic Configuration
This chapter introduces how to configure RC951 equipment to work with RC601, and
includes the following sections.
z RC601 general description
z RC601 configuration list
z Introduction of configuration
z Monitoring and maintenance
9.1.1 RC601 Equipment Basic Configuration
Configure RC601 functions.
9.1.2 RC501 Equipment Basic Configuration List
z Configure fault pass through (fault-pass (enable | disable))

Page 24 of 54

Raisecom Technology Co., Ltd

z
z
z

Remote reset (reset)


Open the port (no shutdown)
Shut down the port (shutdown)

9.1.3 Introduction of Configuration


9.1.3.1 Configure fault pass through (fault-pass (enable | disable))
Step

Command

Description

1
2
3

config
Remote rc601 <1-16>
fault-pass (enable | disable)

Enter global configuration exec


Enter RC601 configuration exec
Configure fault pass through

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc601 1
raisecom(config-RC601/1)# fault-pass enable
raisecom(config-RC601/1)#show interface
9.1.3.2 Remote reset (reset)
Step

Command

Description

1
2
3

config
Remote rc601 <1-16>
reset

Enter global configuration exec


Enter RC601 configuration exec
Reset the remote equipment

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc601 1
raisecom(config-RC601/1)# reset
raisecom(config-RC601/1)#show interface
9.1.3.3 Open the port (no shutdown)
Step

Command

Description

1
2
3

config
Remote rc601 <1-16>
no shutdown

Enter global configuration exec


Enter RC601 configuration exec
Open the port

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc601 1
raisecom(config-rc601/1)# no shutdown
raisecom(config-rc601/1)#show interface
9.1.3.4 Shut down the port (shutdown)
Step

Command

Description

config

Enter global configuration exec

Page 25 of 54

Raisecom Technology Co., Ltd

2
3

Remote rc601 <1-16>


shutdown

Enter RC601 configuration exec


Shut down the port

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc601 1
raisecom(config-RC601/1)# shutdown
raisecom(config-RC601/1)#show interface
9.1.4 Monitoring and Maintenance
Under RC601 configuration exec, user can use show device command to view RC601
current status and configuration.
Raisecom(config-RC601/1)# show device
Basic Info:
Temperature:0
Board Type:RC601-C
Optical Module Type:unknown
Voltage High Alarm:Normal
Voltage Low Alarm:Normal
Fx Info:
Rx Link:DOWN
Tx Link:DOWN
TP Running Info:
Linkstatus:DOWN
Port:Disable
speed-duplex: 100M-half
Fault-pass:Disable
Tp Config Info:
Port:Disable
Fault-pass:Disable

10 RC511 Configuration
10.1 RC511 Basic Configuration
This chapter introduces how to configure RC951 equipment to work with RC511, and
includes the following sections.
z RC511 general description
z RC511 configuration list
z Introduction of configuration
z Monitoring and maintenance
10.1.1 RC511 Equipment Basic Configuration
Configure RC511 functions.
Page 26 of 54

Raisecom Technology Co., Ltd

10.1.2 RC511 Equipment Basic Configuration List


z Configure fault pass through (fault-pass (enable | disable))
z Remote reset (reset)
z Open the port (no shutdown)
z Shut down the port (shutdown)
z Configure auto-negotiation (speed auto)
z Configure speed and duplex mode (speed (100 | 10) duplex (full | half))
z Configure the max frame length (max-frame-length (1536 | 1916))
10.1.3 Introduction of Configuration
10.1.3.1 Configure fault pass through (fault-pass (enable | disable))
Step

Command

Description

1
2
3

config
Remote rc511 <1-16>
fault-pass (enable | disable)

Enter global configuration exec


Enter RC511 configuration exec
Configure fault pass through

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc511 1
raisecom(config-RC511/1)# fault-pass enable
raisecom(config-RC511/1)#show interface
10.1.3.2 Remote reset (reset)
Step

Command

Description

1
2
3

config
Remote rc511 <1-16>
reset

Enter global configuration exec


Enter RC511 configuration exec
Reset the remote equipment

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc511 1
raisecom(config-RC511/1)# reset
raisecom(config-RC511/1)#show interface
10.1.3.3 Open the port (no shutdown)
Step

Command

Description

1
2
3

config
Remote rc511 <1-16>
no shutdown

Enter global configuration exec


Enter RC511 configuration exec
Open the port

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc511 1

Page 27 of 54

Raisecom Technology Co., Ltd

raisecom(config-RC511/1)# no shutdown
raisecom(config-RC511/1)#show interface
10.1.3.4 Shut down the port (shutdown)
Step

Command

Description

1
2
3

config
Remote rc511 <1-16>
shutdown

Enter global configuration exec


Enter RC511 configuration exec
Shut down the port

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc511 1
raisecom(config-RC511/1)# shutdown
raisecom(config-RC511/1)#show interface
10.1.3.5 Configure auto-negotiation (speed auto)
Step

Command

Description

1
2
3

config
Remote rc511 <1-16>
speed auto

Enter global configuration exec


Enter RC511 configuration exec
Configure auto negotiation

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc511 1
raisecom(config-RC511/1)# speed auto
raisecom(config-RC511/1)#show interface
10.1.3.6 Configure speed and duplex mode (speed (100 | 10) duplex (full | half))
Step

Command

Description

1
2
3

config
Remote rc511 <1-16>
Speed (100|10) duplex (full | half)

Enter global configuration exec


Enter RC511 configuration exec
Configure speed and duplex
mode

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc511 1
raisecom(config-RC511/1)# speed 100 duplex half
raisecom(config-RC511/1)#show interface

10.1.3.7 Configure the max frame length (max-frame-length (1536 | 1916))


Step

Command

Description

config

Enter global configuration exec

Page 28 of 54

Raisecom Technology Co., Ltd

2
3

Remote rc511 <1-16>


Speed (100|10) duplex (full | half)

Enter RC511 configuration exec


Configure the max frame length

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc511 1
raisecom(config-rc511/1)# max-frame-length (1536|1916)
raisecom(config-RC511/1)#show interface
10.1.4 Monitoring and Maintenance
Under RC511 configuration exec, user can use show device command to view RC511
current status and configuration.
RAISECOM(config-RC511/1)# show device
Basic Info:
Temperature:0
Optical Module Type:unknown
Voltage High Alarm:Normal
Voltage Low Alarm:Normal
Fx Info:
Rx Link:DOWN
Tx Link:DOWN
SD:Normal
TX Power:Normal
Rx Sensibility:Normal
Laser:Normal
TP Running Info:
Linkstatus:DOWN
Port:Disable
Autonegotiation:disable
speed-duplex: 10M-half
Fault-pass:Disable
Max Frame Length:1536B
Tp Config Info:
Port:Disable
Speed:10M
Duplex:half
Fault-pass:Disable
Max Frame Length:1536B

11 RC511-4FE Configuration
11.1 RC511-4FE Basic Configuration
This chapter introduces how to configure RC951 equipment to work with RC511-4FE, and
Page 29 of 54

Raisecom Technology Co., Ltd

includes the following sections.


z RC511-4FE general description
z RC511-4FE configuration list
z Introduction of configuration
z Monitoring and maintenance
11.1.1 RC511-4FE Equipment Basic Configuration
Configure RC511-4FE functions.
11.1.2 RC511-4FE Equipment Basic Configuration List
z Configure fault pass through (fault-pass (enable | disable))
z Remote reset (reset)
z Configure VLAN (vlan-type (novlan | portvlan))
11.1.3 Introduction of Configuration
11.1.3.1 Configure fault pass through (fault-pass (enable | disable))
Step

Command

Description

1
2

config
Remote rc5114fe <1-16>

fault-pass (enable | disable)

Enter global configuration exec


Enter RC511-4FE configuration
exec
Configure fault pass through

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc5114fe 1
raisecom(config-RC5114FE/1)# fault-pass enable
raisecom(config-RC5114FE/1)#show interface
11.1.3.2 Remote reset (reset)
Step

Command

Description

1
2

config
Remote rc5114fe <1-16>

reset

Enter global configuration exec


Enter RC511-4FE configuration
exec
Reset the remote equipment

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc5114fe 1
raisecom(config-RC5114FE/1)# reset
raisecom(config-RC5114FE/1)#show interface
11.1.3.3 Configure VLAN (vlan-type (novlan | portvlan))
Step

Command

Description

config

Enter global configuration exec

Page 30 of 54

Raisecom Technology Co., Ltd

vlan-type (novlan | portvlan)

reset

Enter RC511-4FE configuration


exec
Configure VLAN

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc5114fe 1
raisecom(config-RC5114FE/1)# vlan-type novlan
raisecom(config-RC5114FE/1)#show interface
11.1.4 Monitoring and Maintenance
Under RC511-4FE configuration exec, user can use show device command to view
RC511-4FE current status and configuration.
RAISECOM(config-RC511/2)# show device
Basic Info:
Version: A.1-1.0-1.0-2.0
Temperature:0
Optical Module Type:unknown
Voltage High Alarm:Normal
Voltage Low Alarm:Normal
Fault-pass:Disable
Vlan Type:Port Vlan
Fx Info:
Rx Link:DOWN
Tx Link:DOWN
SD:Normal
Config Info:
Fault-pass:Disable
Vlan Type:Port Vlan
11.2 RC511-4FE Ethernet Interface Configuration
This chapter introduces how to configure the Ethernet interface of RC511-4FE, and
includes the following sections.
z RC511-4FE Ethernet interface general description
z RC511-4FE Ethernet interface configuration list
z Introduction of configuration
z Monitoring and maintenance
11.2.1 RC511-4FE Ethernet Interface Basic Configuration
Configure RC511-4FE Ethernet interface functions.
11.2.2 RC511-4FE Ethernet Interface Configuration List
z Open the port (no shutdown)
z Shut down the port (shutdown)
Page 31 of 54

Raisecom Technology Co., Ltd

z
z

Configure auto-negotiation (speed auto)


Configure speed and duplex mode (speed (100 | 10) duplex (full | half))

11.2.3 Introduction of Configuration


11.2.3.1 Open the port (no shutdown)
Step

Command

Description

1
2

config
Remote rc5114fe <1-16>

3
4

Interface ethernet<1-4>
no shutdown

Enter global configuration exec


Enter RC511-4FE configuration
exec
Enter Ethernet exec
Open the port

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc5114fe 1
raisecom(config-RC5114FE/1)# interface Ethernet 1
raisecom(config-RC5114FE/1-ethernet/1)# no shutdown
raisecom(config-RC5114FE/1-ethernet/1)#show interface
11.2.3.2 Shut down the port (shutdown)
Step

Command

Description

1
2

config
Remote rc5114fe <1-16>

3
4

Interface ethernet <1-4>


shutdown

Enter global configuration exec


Enter RC511-4FE configuration
exec
Enter Ethernet exec
Shut down the port

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc5114fe 1
raisecom(config-RC5114FE/1)# interface ethernet 1
raisecom(config-RC5114FE/1-ethernet/1)# shutdown
raisecom(config-RC5114FE/1-ethernet/1)#show interface
11.2.3.3 Configure auto-negotiation (speed auto)
Step

Command

Description

1
2

config
Remote rc5114fe <1-16>

3
4

Interface ethernet <1-4>


speed auto

Enter global configuration exec


Enter RC511-4FE configuration
exec
Enter Ethernet exec
Configure auto-negotiation

show interface

Display the configuration

raisecom#config

Page 32 of 54

Raisecom Technology Co., Ltd

raisecom(config)# Remote rc5114fe 1


raisecom(config-RC5114FE/1)# interface ethernet 1
raisecom(config-RC5114FE/1-ethernet/1)#speed auto
raisecom(config-RC5114FE/1-ethernet/1)#show interface
11.2.3.4 Configure speed and duplex mode (speed (100 | 10) duplex (full | half))
Step

Command

Description

1
2

config
Remote rc5114fe <1-16>

3
4

Interface ethernet <1-4>


Speed (100|10) duplex (full|half)

Enter global configuration exec


Enter RC511-4FE configuration
exec
Enter Ethernet exec
Configure the speed and duplex
mode

show interface

Display the configuration

raisecom#config
raisecom(config)# Remote rc5114fe 1
raisecom(config-RC5114FE/1)# interface ethernet 1
raisecom(config-RC5114FE/1-ethernet/1)# speed 100 duplex half
raisecom(config-RC5114FE/1-ethernet/1)#show interface
11.2.4 Monitoring and Maintenance
Under RC511-4FE exec, user can use show interface command to view RC511-4FE
current status and configuration.
RAISECOM(config-RC5114FE/1-ethernet/1)# show interface
port 1:
Running Info:
Linkstatus:DOWN
Port:Disable
Autonegotiation:disable
speed-duplex: 10M-half
Rate Limit:10x32k/s
Config Info:
Port:Disable
Speed:10M
Duplex:half
Rate limit:3200x32k/s

12 Map Configuration
This chapter introduces how to configure map on RC951, and including the following
sections.
z Map general description
Page 33 of 54

Raisecom Technology Co., Ltd

z
z
z

Map configuration list


Introduction of configuration
Monitoring and maintenance

12.1 Map General Description


Map configures the communication mode for Ethernet interface and E1 interface. In the
same map, all Ethernet interfaces are interconnected, E1 interfaces and Ethernet
interfaces are interconnected, but E1 interfaces are isolated from each other.
12.2 Map Configuration List
z Create map (add map NAME Ethernet {1-8} [e1 {1-16}])
z Modify map (modify map NAME Ethernet {1-8} [e1 {1-16}])
z Delete map (no map NAME)
12.3 Introduction of Configuration
12.3.1 Create map (add map NAME Ethernet {1-8} [e1 {1-16}])
Command

Description

config
add map NAME ethernet {1-8}
[e1 {1-16}]
show map

Enter config exec


Create map
Display map

Raisecom#config
Raisecom(config)#add map map1 ethernet 1-3 e1 1-6
Raisecom(config)#show map
12.3.2 Modify map (modify map NAME Ethernet {1-8} [e1 {1-16}])
Command

Description

config
modify map NAME
{1-8} [e1 {1-16}]
show map

Enter config exec


Modify map

ethernet

Display map

Raisecom#config
Raisecom(config)#modify map map1 ethernet 1-3 e1 1-6
Raisecom(config)#show map
12.3.3 Delete map (no map NAME)
Command

Description

config
no map NAME
show map

Enter config exec


Delete map
Display map

Raisecom#config
Raisecom(config)#no map map1
Page 34 of 54

Raisecom Technology Co., Ltd

Raisecom(config)#show map
12.4 Introduction of Configuration
Under config exec, user can use show map command to view interface map current
status and configuration. This command is used to display the map configuration
information.
RAISECOM(config)#show map
Name
Ethernet List
1
1

E1 List
4

13 Network Management Interface Configuration


This chapter introduces how to configure network management interface on RC951, and
including the following sections.
z Network management interface general description
z Network management interface configuration list
z Introduction of configuration
z Monitoring and maintenance
13.1 Network Management Interface General Description
Configure RC951-8FE16E1 network management interface basic functions
13.2 Network Management Interface Configuration List
z Configure a port as management port (mgmt-port <1-8>)
z Shut down management port (no mgmt-port <1-8>)
13.3 Introduction of Configuration
13.3.1 Configure a port as management port (mgmt-port <1-8>)
Command

Description

config
mgmt-port <1-8>
show interface ethernet [{1-8}]

Enter config exec


Configure a port as management port
Display the status of the port

Raisecom#config
Raisecom(config)#mgmt-port 1
Raisecom(config)#show interface ethernet
13.3.2 Shut down management port (no mgmt-port <1-8>)
Command

Description

config
no mgmt-port <1-8>
show interface ethernet [{1-8}]

Enter config exec


Shut down the management port
Display the status of the port

Page 35 of 54

Raisecom Technology Co., Ltd

Raisecom#config
Raisecom(config)#no mgmt-port 1
Raisecom(config)#show interface ethernet
13.4 Monitoring and Maintenance
Under config user exec, user can use show interface Ethernet command to view interface
current status and configuration. This command is used to display interface configuration
information.
Raisecom(config)#show interface ethernet 1
Port 1:
Basic Info:
Linkstatus:down
speed-duplex: 10M-half
Manage port:On
Config Info:
Port Switch:On
Auto negotiate:enable
auto-MDIX:enable
flowcontrol:ON
Performance Statistics:
TX Packet Number:0
TX Bytes Number:0
RX Packet Number:0
RX Bytes Number:0
RX Lost Packet Number:0
Collision Number:0

14 SNMP Configuration
This chapter introduces how to configure SNMP on RC951, and includes the following
sections.
z SNMP general description
z SNMP configuration list
z Introduction of configuration
z Monitoring and maintenance
14.1 SNMP General Description
RC951-8FE16E1 supports the way of management through SNMP Agent.
14.2 SNMP Configuration List
z Configure community name
z Enable or disable trap
z Configure trap manager and port number

Page 36 of 54

Raisecom Technology Co., Ltd

z
z
z
z
z
z

Delete trap manager


Erase all trap configuration
Configure contact information
Configure location information
Configure name information
Configure description information

14.3 Introduction of Configuration


14.3.1 Configure community name
Step

Command

Description

1
2

snmp
Snmp-server
community
COMMUNITY (ro|rw)

Enter SNMP configuration exec


Configure read-only community
and read-write community

show snmp

Display SNMP configuration

raisecom#snmp
raisecom(config-SNMP)# Snmp-server
raisecom(config-SNMP)# show snmp

community

public ro

14.3.2 Enable or disable trap


Step

Command

Description

1
2

snmp
Snmp-server
(enable|disable)

Enter SNMP configuration exec


Enable or disable trap

show snmp

trap

Display SNMP configuration

raisecom#snmp
raisecom(config-SNMP)# Snmp-server trap
raisecom(config-SNMP)# show snmp

enable

14.3.3 Configure trap manager and port number


Step

Command

Description

1
2

snmp
Snmp-server trap <1-8> target
A.B.C.D port <1-65536>

Enter SNMP configuration exec


Configure trap manager and port
number.
trap: configure trap manager
<1-8>
Target: IP address of manager
PORT: port number

show snmp

Display SNMP configuration

raisecom#snmp
raisecom(config-SNMP)# Snmp-server
raisecom(config-SNMP)# show snmp

trap

1 target 192.168.1.1 port 162

Page 37 of 54

Raisecom Technology Co., Ltd

14.3.4 Delete trap manager


Step

Command

Description

1
2

snmp
no Snmp-server trap

Enter SNMP configuration exec


Delete trap manager

show snmp

<1-8>

Display SNMP configuration

raisecom#snmp
raisecom(config-SNMP)# no Snmp-server trap 1
raisecom(config-SNMP)# show snmp
14.3.5 Erase all trap configuration
Step

Command

Description

1
2

snmp
Snmp-server trap clear

Enter SNMP configuration exec


Erase all trap configuration

show snmp

Display SNMP configuration

raisecom#snmp
raisecom(config-SNMP)# Snmp-server trap clear
raisecom(config-SNMP)# show snmp
14.3.6 Configure contact information
Step

Command

Description

1
2

snmp
Snmp-server contact STRING

Enter SNMP configuration exec


Configure contact information

show snmp

Display SNMP configuration

raisecom#snmp
raisecom(config-SNMP)# Snmp-server contact STRING
raisecom(config-SNMP)# show snmp
14.3.7 Configure location information
Step

Command

Description

1
2

snmp
Snmp-server
LOCATION

Enter SNMP configuration exec


Configure location information

show snmp

location

Display SNMP configuration

raisecom#snmp
raisecom(config-SNMP)# Snmp-server location haidian
raisecom(config-SNMP)# show snmp
14.3.8 Configure name information
Step

Command

Description
Page 38 of 54

Raisecom Technology Co., Ltd

1
2

snmp
Snmp-server name NAME

Enter SNMP configuration exec


Configure name information

show snmp

Display SNMP configuration

raisecom#snmp
raisecom(config-SNMP)# Snmp-server name RAISECOM
raisecom(config-SNMP)# show snmp
14.3.9 Configure description information
Step

Command

Description

1
2

snmp
snmp-server
STRING

Enter SNMP configuration exec


Configure description information

show snmp

description

Display SNMP configuration

raisecom#snmp
raisecom(config-SNMP)# snmp-server description RAISECOM
raisecom(config-SNMP)# show snmp
snmp-server description STRING
14.4 Monitoring and Maintenance
Under configuration user exec, user can use show snmp command to view snmp current
status and configuration. This command is used to display snmp configuration
information.
Step

Command

Description

1
2

Snmp
Show snmp

Enter SNMP configuration exec


Display
SNMP
configuration
information

raisecom(config)# show snmp


System name:
unknown
System description:
rc951-8fe16e1
System contact:
unknown
System location:
unknown
System object id: 1.3.6.1.4.1.8886.2
Read Community:public
Write Community:private
Send trap status:
Enable
Trap sink
Target Address
Target Port
1
0.0.0.0
162
2
0.0.0.0
162
3
0.0.0.0
162
4
0.0.0.0
162
5
0.0.0.0
162
6
0.0.0.0
162
Page 39 of 54

Raisecom Technology Co., Ltd

7
8

0.0.0.0
0.0.0.0

162
162

15 Examples of Configuring RC951-8FE16E1 and RC952


RC951 equipment provides 8 Ethernet interfaces and 16 E1 interfaces. They can be
flexibly configured to satisfy different types of requirement according to complicated
network topologies.
When RC951-8FE16E1 is working in pairs with RC952-FXE1, the topology is as follows.

Service
SNMP

8 x Ethernet

RC951-8 FE16E1
16 x E1

When the Agent in


RC951 managing the
whole network,
RC951 can manage
over RC952-FXE1
and the remote media
converter connecting
to the optical
interface of RC952
E1

E1

RC952-FXE1

RC952-FXE1
E1

RC952-FXE1
RC601- FE

RC501- FE
RC501- FE

Figure 1. RC951-8FE16E1 working with RC952-FXE1

Page 40 of 54

Raisecom Technology Co., Ltd

When RC951-8FE16E1 is working in pairs with RC952-FEE1, the topology is as follows.

Service
SNMP

8 x Ethernet

RC951-8 FE16E1
16 x E1
When the Agent
in RC951
managing the
whole network,
the RC951 can
manage over
RC952-FEE1
E1

E1

RC952-FEE1

RC952-FEE1
E1

RC952-FEE1

Figure 2. RC951-8FE16E1 working with RC952-FEE1

The configuration details are as follows.


The network management port of RC951-8FE16E1 is the first Ethernet interface. 3
numbers of RC952-FEE1 shall be connected to the first 3 E1 interfaces of
RC951-8FE16E1 respectively. All data traffic from the first 3 E1 interfaces will be
aggregated to the second Ethernet interface of RC951-8FE16E1.
Configuration procedure:
1. configure IP and gateway address
raisecom#config
Configuration mode, one command input per times. End with CTRL-Z.
raisecom(config)#ip 192.168.4.64 mask 255.255.255.0
set command success
please execute "write" to save!
raisecom(config)# gateway 192.168.4.1
set command success

Page 41 of 54

Raisecom Technology Co., Ltd

please execute "write" to save!


raisecom(config)#show ip
IP
Addr: 192.168.4.64
subnet Mask: 255.255.255.0
GATEWAY Addr: 192.168.4.1
raisecom(config)#write
Writing running-config to flash, please wait...
Copy OK: 2699 bytes copied
Successfully write to flash
raisecom(config-SNMP)#end
raisecom#
2. configure SNMP community name and trap manager address
raisecom#config
Configuration mode, one command input per times. End with CTRL-Z.
raisecom(config)#snmp
raisecom(config-SNMP)#snmp-server community public ro
set command success
please execute "write" to save!
raisecom(config-SNMP)#snmp-server community private rw
set command success
please execute "write" to save!
raisecom(config-SNMP)#snmp-server trap 1 target 192.168.4.63 port 162
set command success
please execute "write" to save!
raisecom(config-SNMP)#show snmp
System name:
unknown
System description:
rc951-8fe16e1
System contact:
unknown
System location:
unknown
System object id: 1.3.6.1.4.1.8886.2
Read Community:public
Write Community:private
Send trap status:
Enable
Trap sink
Target Address
Target Port
1
192.168.4.63
162
2
0.0.0.0
162
3
0.0.0.0
162
4
0.0.0.0
162
5
0.0.0.0
162
6
0.0.0.0
162
7
0.0.0.0
162
8
0.0.0.0
162

Page 42 of 54

Raisecom Technology Co., Ltd

raisecom(configSNMP)#write
Writing running-config to flash, please wait...
Copy OK: 2699 bytes copied
Successfully write to flash
raisecom(config-SNMP)#end
raisecom#
3. configure the network management port (configure the first Ethernet interface as
network management port)
raisecom#config
Configuration mode, one command input per times. End with CTRL-Z.
raisecom(config)#mgmt-port 1
set command success
if you want to save it, please execute "write" to save!
raisecom(config)#write
Writing running-config to flash, please wait...
Copy OK: 2699 bytes copied
Successfully write to flash
raisecom(config)#end
raisecom#
4. configure map (configure the second Ethernet interface and the first 3 E1 interfaces
into one map, so that data traffic from the first 3 E1 interfaces will be aggregated to the
second Ethernet interface. Data traffic between E1 interfaces are isolated.)
raisecom#config
Configuration mode, one command input per times. End with CTRL-Z.
raisecom(config)#add map map1 ethernet 2 e1 1-3
set command success.
if you want to save it, please execute "write" to save!
raisecom(config)#show map
Name
Ethernet List
E1 List
map1
2
1-3
raisecom(config)#write
Writing running-config to flash, please wait...
Copy OK: 2699 bytes copied
Successfully write to flash
raisecom(config)#end
raisecom#

Page 43 of 54

Raisecom Technology Co., Ltd

5. configure Ethernet interface property (only one interface is configured in the example.
Others are the same)
raisecom#config
Configuration mode, one command input per times. End with CTRL-Z.
raisecom(config)#int ethernet 2
raisecom(config-ethernet-2)#speed auto
set command success
if you want to save it, please execute "write" to save!
raisecom(config-ethernet-2)#flow-control on
set command success
if you want to save it, please execute "write" to save!
raisecom(config-ethernet-2)#show int
Port 2:
Basic Info:
Linkstatus:down
speed-duplex: 10M-half
Manage port:Off
Config Info:
Port Switch:On
Auto negotiate:enable
auto-MDIX:enable
flowcontrol:ON
Performance Statistics:
TX Packet Number:0
TX Bytes Number:0
RX Packet Number:0
RX Bytes Number:0
RX Lost Packet Number:0
Collision Number:0
raisecom(config-ethernet-2)#write
Writing running-config to flash, please wait...
Copy OK: 2699 bytes copied
Successfully write to flash
raisecom(config-ethernet-2)#end
raisecom#
6. configure E1 interface property ((only one interface is configured in the example.
Others are the same)
raisecom#config
Configuration mode, one command input per times. End with CTRL-Z.
raisecom(config)#interface e1 1
raisecom(config-E1/1)#clock-mode master

Page 44 of 54

Raisecom Technology Co., Ltd

set command success


if you want to save it, please execute "write" to save!
raisecom(config-E1/1)#crc-auto enable
set command success
if you want to save it, please execute "write" to save!
raisecom(config-E1/1)#flow-control on
set command success
if you want to save it, please execute "write" to save!
raisecom(config-E1/1)#show int
E1:1
Basic Info:
Clock-mode:master
Frame Mode:unframed
Frame timeslot:n/a
Frame CRC State:disable
Frame CRC Autonegotiation:enable
Flow control:ON
Maintenance:
Loop Back(config):disable
Lineloop(config):disable
Bert:disable
Packet Statistics:
TX Packet Number:81384
RX Packet Number:0
RX Error Packet Number:0
Performance Statistics:
Error Second:0
Serial Error Second:0
Bit Error Rate: Zero
Fault State:
LOS:Failure
AIS:Normal
LOF:Normal
CRC:Normal
raisecom(config-E1/1)#write
Writing running-config to flash, please wait...
Copy OK: 2699 bytes copied
Successfully write to flash

Page 45 of 54

Raisecom Technology Co., Ltd

raisecom(config-E1/1)#end
raisecom#
7. test E1 interface (only one interface is configured in the example. All others are the
same)
raisecom#config
Configuration mode, one command input per times. End with CTRL-Z.
Configure remote loop-back.
raisecom(config-E1/1)# remote-e1-loopback
set command success
Enable the BERT function.
raisecom(config-E1/1)#bert enable
set command success
raisecom(config-E1/1)#show int
E1:1
Basic Info:
Clock Mode:master
Frame Mode:unframed
Frame timeslot:n/a
Frame CRC State:disable
Frame CRC Autonegotiation:enable
Flow control:ON
Maintenance:
Loop Back(config):disable
Lineloop(config):enable
Lineloop(result):Success
Bert:enable
Packet Statistics:
TX Packet Number:0
RX Packet Number:0
RX Error Packet Number:0
Performance Statistics:
Error Second:15
Serial Error Second:15
Bit Error Rate: thousandth
Fault State:
LOS:Failure
AIS:Normal
LOF:Normal
CRC:Normal

Page 46 of 54

Raisecom Technology Co., Ltd

Disable BERT function and loop-back on remote equipment, and configure local
loop-back.
raisecom(config-E1/1)#bert disable
set command success
raisecom(config-E1/1)#no remote-e1-loopback
set command success
Enable equipment local loop-back.
raisecom(config-E1/1)#loopback
set command success
Enable BERT.
raisecom(config-E1/1)#bert enable
set command success
raisecom(config-E1/1)#show int
E1:1
Basic Info:
Clock Mode:master
Frame Mode:unframed
Frame timeslot:n/a
Frame CRC State:disable
Frame CRC Autonegotiation:enable
Flow control:ON
Maintenance:
Loop Back(config):disable
Lineloop(config):enable
Lineloop(result):Success
Bert:enable
Packet Statistics:
TX Packet Number:0
RX Packet Number:0
RX Error Packet Number:0
Performance Statistics:
Error Second:15
Serial Error Second:15
Bit Error Rate: thousandth
Fault State:
LOS:Failure
AIS:Normal
LOF:Normal
CRC:Normal
Disable BERT.
raisecom(config-E1/1)#bert disable

Page 47 of 54

Raisecom Technology Co., Ltd

set command success


Disable Equipment local loop-back.
raisecom(config-E1/1)#no loopback
set command success
raisecom(config-eth/1)#end
raisecom#
8. configure remote RC952-FEE1 (all the three RC952 are the same)
raisecom#config
Configuration mode, one command input per times. End with CTRL-Z.
raisecom(config)#remote interfaceconvert 1
raisecom(config-RC952FEE1/1)#
Enable fault-pass-through.
raisecom(config-RC952FEE1/1)#fault-pass enable
set command success
if you want to save it, please execute "write" to save!
Enter Ethernet interface configuration exec.
raisecom(config-RC952FEE1/1)#interface ethernet
raisecom(config-RC952FEE1/1-ethernet)#
Configure Ethernet interface to auto-negotiation.
raisecom(config-RC952FEE1/1-ethernet)#speed auto
set command success
if you want to save it, please execute "write" to save!
Enable flow control.
raisecom(config-RC952FEE1/1-ethernet)#flow-control on
set command success
if you want to save it, please execute "write" to save!
View Ethernet interface information.
raisecom(config-RC952FEE1/1-ethernet)#show interface
Port 1:RC952FEE1
Basic Info:
Port:Enable
Linkstatus:Down
Autonegotiation:enable
speed-duplex: 10M-half
flowcontrol:ON
Config Info:
Port:Enable
Speed:Autonegotiation
flowcontrol:ON
Ethernet Performance Statistics:
TX Packet Number:81
RX Packet Number:0
RX Error Packet Number:0

Page 48 of 54

Raisecom Technology Co., Ltd

raisecom(config-RC952FEE1/1-ethernet)#exit
raisecom(config-RC952FEE1/1)#
Enter E1 interface configuration exec.
raisecom(config-RC952FEE1/1)#interface e1
raisecom(config-RC952FEE1/1-E1)#
Configure master clock.
raisecom(config-RC952FEE1/1-E1)#clock-mode master
set command success
if you want to save it, please execute "write" to save!
Enable CRC auto-negotiation.
raisecom(config-RC952FEE1/1-E1)#crc-auto enable
set command success
if you want to save it, please execute "write" to save!
View E1 interface information.
raisecom(config-RC952FEE1/1-E1)#show interface
Port 1:RC952FEE1
Basic Running Info:
Clock Mode:master
Frame Mode:unframed
Frame timeslot:N/A
Frame CRC autonegotiation:enable
Frame CRC Check:disable
Basic Config Info:
Clock Mode:master
Frame Mode:unframed
Frame timeslot:N/A
Frame CRC autonegotiation:enable
Packet Statistics:
TX Packet Number:0
RX Packet Number:143
RX Error Packet Number:0
Fault State:
LOS:Normal
AIS:Normal
LOF:Normal
CRC:Normal
raisecom(config-RC952FEE1/1-E1)#end
raisecom(config)#

Page 49 of 54

Raisecom Technology Co., Ltd

BROADBAND

to RAISECOM

Copyright Declaration: Raisecom Technology Co., Ltd. is the owner of this manual booklet.
This manual is not allowed to reproduce without Raisecoms written permission.
All rights Reserved.

Address: 2nd Floor, South Building of Rainbow Plaza, No.11 Shangdi Information Road, Haidian District, Beijing
Postcode: 100085
Tel: +86-10-82883305
Fax: +86-10-82883056
Email: export@raisecom.com
http://www.raisecom.com

Page 50 of 54