DATASHEET NUMBER
DATA SHEET
CLIENT :
SHEET NO. 1 OF 1
02
01
MSP-HPU-XXXX-XX
ICP-HPU-XXXX-XX
One
One
For actuating Subsea Ball valve with single acting, spring For actuating Subsea Ball valve with single acting, spring
return, subsea hydraulic actuator
return, subsea hydraulic actuator (Note 1)
Item Number
Tag Number
Quantity
P & ID Number
Service
SSIV
GENERAL
HPU CUM CONTROL PANEL
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
550
Two (Supply/Return, 1 No spare) / 3/4" NB
70 - 105
160
Two (OPEN and CLOSE indication)
Signal, U/Uo = 0.6/1.0 kV rms
4 / 6 mm
Plain copper, high conductivity
Class 1, Div 1, Gr C & D, T3 (Applicable for HPU)
SSIV located at 76 Mts water depth
550
Two (Supply/Return, 1 No spare) / 3/4" NB
70 - 105
160
Two (OPEN and CLOSE indication)
Signal, U/Uo = 0.6/1.0 kV rms
4 / 6 mm
Plain copper, high conductivity
Class 1, Div 1, Gr C & D, T3 (Applicable for HPU)
SSIV located at 76 Mts water depth
Location
SSIV actuation and valve status indication
Provision to accept ESD and FSD signals
Hydraulic reservoir - Material
Hydraulic reservoir - Capacity
Hydraulic accumulators - Material
Hydraulic accumulators - Size
Hydraulic accumulators - ASME code stamp
Hydraulic pumps
415 5%, TPN, 50Hz 3% provided at single point. Any 415 5%, TPN, 50Hz 3% provided at single point. Any
other voltage required shall be derived by vendor.
other voltage required shall be derived by vendor.
Power supply
Filters at suction of hydraulic pump
Panel mounted instruments - Material
Tubes and Tube fittings
Cerification
Distance between HPU and SSIV
35
36
37
38
39
40
41
Water based biodegradable type with requisite addition of Water based biodegradable type with requisite addition of
biocide consisting of de-ionised water, biocide and water biocide consisting of de-ionised water, biocide and water
42
soluble lubricant (Martson bentley, HW560) Cleanliness soluble lubricant (Martson bentley, HW560) Cleanliness
level NAS 1638 Class 6)
level NAS 1638 Class 6)
Manufacturer
OPTIONS
NOTES
5
6
Body Type
Vendor to specify
Vendor to specify
Not Required
Required as per clause no 3.2 of FS-3506
Note:
1. The HPU shall also include pneumatic shutdown logic (dual) module for topside pig receivers. The pneumatic shutdown logic module shall be as per ONGC
Functional specification for shutdown panel, FS-3501 and approved cause and effect diagram (Will be provided later) and Annexure I
REVISION NO.
PEM STATUS
ISSUED FOR
PREPD. BY/DATE
CHKD. BY/DATE
APPD. BY/DATE
REV
1
2
3
4
A
S3
ENQUIRY
B
S4
PURCHASE
43
44
45
46
47
48
49
50
51
52
53
54