Vous êtes sur la page 1sur 5

This calculation has been carried out using the program comissioned by the Saint-Gobain Isover Hungaria Ltd

Input data
Geometry
Biggest floor area:
Brutto floor area:
Net floor area:
Heated floor area:
Average ceiling height:
Building perimeter:

117 [m2]
189 [m2]
117 [m2]
117 [m2]
6.00 [m]
43.0 [m]

Lowest floor slab


Floor slab on the soil:
Unheated basement:
Heated space:
Unheated space:
Arcade:

117 [m2]
0 [m2]
0 [m2]
0 [m2]
0 [m2]

Vertical insulation
Geodetic height:
Thermal resistance:
Depth of thermal insulation:
Horizontal insulation
Geodetic height:
Thermal resistance:

0.50 [m]
3.00 [m2K/W]
0.10 [m]
0.50 [m]
5.00 [m2K/W]

Roof:
Pitched roof:
Heated attic

Garret with outer parapet


Exists
Exists

Density of internal partitions:


Configuration in layout:
Configuration in section:

Average
Average
Compact

Elevation areas:
Elevation area, including exposed and facing to sunspace
Facing to N:
Facing to NE:
Facing to E:
Facing to SE::
Facing to S:
Facing to SW:
Facing to W:
Facing to NW:

N:
E:
S:
W:

Facade elements in section


None
None
Balconies
None

70 [m2]
0 [m2]
65 [m2]
0 [m2]
37 [m2]
0 [m2]
33 [m2]
0 [m2]

Facade elements in projection


--------------------Sparse
-----------

This calculation has been carried out using the program comissioned by the Saint-Gobain Isover Hungaria Ltd

Transparent elements
Glazing
N:
E:
S:
W:
Mullion
Orient.
N:
E:
S:
W:

10 [m2]
7 [m2]
15 [m2]
4 [m2]

triple glazing, Alu frame


triple glazing, Alu frame
triple glazing, Alu frame
triple glazing, Alu frame

Mullion
Sparse
Sparse
Average
Very sparse

Tilted glazing
Orient.
Area

Perimeter/area
Average
Small
High
Very small

Movable shading
Curtain
Blind + curtain
Direct input (R=0.18 g=0.30)
Direct input (R=0.00 g=0.00)

Tilt

Window type

Indirect systems
Sunspace data:
Orient.
Area [m2]

Window area [m2]

ACH. [1/h]

Orient.

Roof

Layout

Mass wall data:


Orient.
Area

Mullion

Glazing

Night insulation

Surface finishing

Trombe wall data:


Orient.
Area

Mullion

Glazing

Movable shading

Surface finishing

Transparent insulation data:


Orient.
Area

Mullion

Movable shading

Transmittance

TRI R

Deciduous vegetation
few
medium
few
medium

Evergreen vegetation
disperse
few
medium
few

Frame

Window type

Glazing type.

Movable shading

Opaque wall R

Solar access
Solar access:
Orient.
Building in layout
N:
none
E:
none
S:
none
W:
none

Building in section
none
none
none
none

Constructional data
Constructional data
Floor covering in rooms, facing to
Orient.
Floor covering
N:
Heavy
E:
Heavy
S:
Heavy
W:
Heavy
Position of thermal insulation:
Specific mass of exposed wall:
Specific mass of floor slabs:
Specific mass of partition walls:

External
1400-1700 kg/m3
Heavy
160-200 kg/m2

This calculation has been carried out using the program comissioned by the Saint-Gobain Isover Hungaria Ltd

Building use
Indoor set temperature:
Design external temperature:
Air change per hour:
Heat recovery:
Building use:
Heating system control:
Number of occupants - conventional heat gain:
Summer ventilation of rooms facing to
N:
intensive
E:
intensive
S:
intensive
W:
intensive
Fuel data:
Fuel price per MJ:
Heat value per other unit:
Efficiency of heating system:

3.0
-----81.00

20.0 [C]
-12.0 [C]
1.0 [1/h]
None
Residential
average
4 [capita]

This calculation has been carried out using the program comissioned by the Saint-Gobain Isover Hungaria Ltd

Output
Regarding summer overheating the thermal mass is :
for N orientation
acceptable
for E orientation
acceptable
for S orientation
acceptable
for W orientation
acceptable

Heat transfer coefficient {thermal resistance}:


Exposed walls:
Heated attic envelope:

Heat load:
Yearly heating energy cost:

0.63 { 1.59}
0.42 { 2.38}

17.0 [kW]
421823

Average U value:
Average thermal resistance:
Average U value including thermal bridge effect:
Average thermal resistance including thermal bridge effect:
Transmission heat loss coefficient:
Transmission heat loss coefficient per floor area:
Transmission heat loss coefficient per volume:
Heat loss coefficient:
Heat loss coefficient per floor area:
Heat loss coefficient per volume:
Net balance of transmission losses and utilised direct solar gains:
Net balance of transmission losses and utilised direct solar gains per floor area:
Net balance of transmission losses and utilised direct solar gains per volume:
Net heat loss coefficient:
Net heat loss coefficient per floor area:
Net heat loss coefficient per volume:
Heating energy consumption per floor area:
Heating energy consumption per volume:

0.456 [W/m2K]
2.193 [m2K/W]
0.510 [W/m2K]
1.962 [m2K/W]
293.316 [W/K]
2.507 [W/Km2]
0.418 [W/Km3]
531.996 [W/K]
4.547 [W/Km2]
0.758 [W/Km3]
260.965 [W/K]
2.230 [W/Km2]
0.372 [W/Km3]
420.102 [W/K]
3.591 [W/Km2]
0.598 [W/Km3]
270 [W/m2]
45 [W/m3]

Informative data
Month
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Sum:

Total heat gain


[kWh/day]

Utilised heat gain


[kWh/day]
31.1
38.5
46.6
54.0
-----45.3
35.2
29.7

31.1
38.5
46.6
52.9
-----44.4
35.2
29.7

Heating energy consumption


[kWh/month]
7269.2
5677.6
4057.9
1745.1
0.0
0.0
0.0
0.0
0.0
1869.4
4535.6
6481.9
31636.7

This calculation has been carried out using the program comissioned by the Saint-Gobain Isover Hungaria Ltd

Energy consumption of auxiliary heating

[kWh/month]
10000.0

8000.0

6000.0

4000.0

2000.0

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

Vous aimerez peut-être aussi