Vous êtes sur la page 1sur 66

HP0-053

Enterprise Integration and Management of HP ProLiant Servers


Version 2.0

Table of contents
Topic 1, Practice (61 Questions)..............................................................................................................................4
Topic 2, Practice (140 Questions)..........................................................................................................................20

Total number of questions: 201

Topic 1, Practice (61 Questions)


QUESTION NO: 1
Which features does Proactive 24 and Support Plus 24 have in common? (Choose two.)
A. 4-hour hardware 13x5
B. Software technical assistance
C. Change management
D. Software updates
E. Account Management
Answer: B,D
QUESTION NO: 2
What are the leading industry standard technologies that HP ProLiant Essentials Vulnerability Management
Pack (VPM) is based on? (Choose two.)
A. HP Openview management suite using Radia patch management technology
B. Microsoft Operations Manager (MOM) for Windows Operating systems
C. Harris Security Threat Avoidance technology (STAT) scanning technology
D. Ignite-UX Graphical Interface (GUI) technology
E. HP systems insight manager (SIM) version control repository manager technology
Answer: A,C
QUESTION NO: 3
What is a key advantage of Virtual Connect for HP c-class BladeSystem?
A. Virtual Connect is a built in manager for virtual machines from VMWare, XEN and Microsoft Virtual Server
B. SAN and network resources can be presented once to the switch; then assigned or re-assigned required
C. Blades can be joined via the switch to form one logical server that can be send and used as one server by an
operating system
D. Resources such as CPU and memory can be abstracted to create virtual machines within the blade chassis
Answer: B
QUESTION NO: 4
Which HP Proliant tool monitors hardware and operating system performance levels to performance levels?
A. Workload Management Pack (WMP)
B. WebBench

C. Performance Management Pack (PMP)


D. Vulnerability and Patch Management (VPM) pack
Answer: C
QUESTION NO: 5
The IT administrator noticed that the application server's disk queue is saturated management pack (PMP). She
determined that she need to upgrade the cache on the disk controller.
Which part of the HP Troubleshooting Methodology does this reflect?
A. Develop an itemized action plan
B. Evaluate the data to determine potential subsystems causing issue
C. Collect data
D. Problem solved
E. Execute the action plan
F. Implement preventative measures
Answer: A
QUESTION NO: 6
When connecting to another server through the Remote Lights-out board, HP recommends HPLOMOPT utility
to automate the configuration of optimum mouse settings.
Where does this utility need to be installed?
A. On the target server
B. On the client
C. On the HP SIM management server
D. On the client and target server
Answer: A
QUESTION NO: 7
Which plan is considered to be a scale-out action plan?
A. Adding faster disk subsystems
B. Adding Memory
C. Distributing computing or clustering
D. Adding additional processors
Answer: C

QUESTION NO: 8
Certpaper.com wants to install several new servers but needs to incorporate a simplified cabl system. Which
Proliant server series best meets this requirement?
A. BL Series
B. CL Series
C. DL Series
D. ML Series
Answer: A
QUESTION NO: 9
Which HP OpenView Storage Mirroring operation allows you to continuously capture changes as they occur?
A. Restoration
B. Failure monitoring and failover
C. Replication
D. Mirroring
Answer: C
QUESTION NO: 10
What are the leading industry standard technologies that HP ProLiant Essentials Vulnerability Management
Pack (VPM) is based on? (Choose two.)
A. Harris Security Threat Avoidance technology (STAT) scanning technology
B. HP systems insight manager (SIM) version control repository manager technology
C. Ignite-UX Graphical Interface (GUI) technology
D. Microsoft Operations Manager (MOM) for Windows Operating systems
E. HP Openview management suite using Radia patch management technology
Answer: A,E
QUESTION NO: 11
You want to use the performance Management Pack (PMP) version 3.1 or higher to manage servers sharing two
MSA1500 storage systems. How many PMP licenses are required?
A. 4
B. 2
C. 1
D. 5
E. 3

Answer: D
QUESTION NO: 12
Complete maintenance of the Proliant Support and Smart Components involves understanding which version
Control Repository tasks?
A. Monitoring, copying and creating custom support packs
B. Monitoring, deleting and copying support packs
C. Updating and copying support packs
D. Monitoring, deleting, copying and creating custom support packs
Answer: D
QUESTION NO: 13
Self Solved and Assisted solved are ways problem resolution can be accomplished using Support solution?
A. HP ISDE (Instant Support DataCenter Edition)
B. ISCE (Instant Support Corporate Edition)
C. HP ISPE (Instant Support Corporate Edition)
D. ISEE (Instant Support Enterprise Edition)
Answer: B
QUESTION NO: 14
What is the maximum number of physical processors supported in ProLiant BL p-class systems?
A. 2
B. 6
C. 4
D. 8
Answer: C
QUESTION NO: 15
You want to use Performance Management Pack to analyze the performance of a Proliant server that runs batch
jobs at night.
Which method is most convenient?
A. Offline Analysis
B. Online Analysis

C. Static Analysis report


D. System Summary Report
Answer: A
QUESTION NO: 16
In an HP Bladesystem p-class power enclosure, which module reports thermal, power and protection events by
communicating with the iLO ASIC?
A. Power backplane module
B. Signal backplane module
C. Power Management module
D. Blade management module
Answer: C
QUESTION NO: 17
How do c-class Bladesystems provide greater SAN connectivity and redundancy than p-class Bladesystem
servers?
A. By using Emulex instead of Qlogic ASICs
B. By providing support for the XP storage arrays
C. By using Qlogic dual channel ASICs instead of single channel ASICs
D. By providing the ability to have multiple fiber channel mezzanine cards
Answer: D
QUESTION NO: 18
What is a valid method to configure iLO?
A. Smart start
B. iLO Rom Based Setup Utility (RBSU)
C. iLO Setup utility
D. Simple Network Management Protocol (SNMP)
Answer: B
QUESTION NO: 19
Two arrays are configured on one smart array 6400 (SA6400) controller channel. One array consists of two
Ultra 320 and three Ultra 3 hard drives and the other array consist of three Ultra 320 and two Ultra hard drives.

With a mix Ultra 320 and Ultra 3 hard drives, which will help increase performance in the Ultra 320 storage
subsystem?
A. Add two port expansion module (SA6400 EM)
B. Keep Ultra 320 and Ultra 3 hard drives in separate SCSI channels
C. Do nothing because all hard drives will run at Ultra 3
D. Keep Ultra 320 hard drives and Ultra 3 hard drives in separate arrays
Answer: D
QUESTION NO: 20
Where can you install HP Workload Management Pack to manage resources? (Choose two.)
A. Network 5.0
B. RedHat Linux
C. Windows 2003
D. Windows 2000
E. SuSe Linux
Answer: C,D
QUESTION NO: 21
The IT administrator noticed that the applicant server's disk queue is saturated management pack (PMP). She
determined that she needs to upgrade the cache on the disk controller.
Which part of the HP Troubleshooting Methodology does this reflect?
A. Execute the action plan
B. Develop an itemized action plan
C. Evaluate the data to determine potential subsystems causing issue
D. Problem solved
E. Implement preventative measures
F. Collect Data
Answer: B
QUESTION NO: 22
What is one difference between Transmit load balancing (TLB) and Switch-assisted load balancing?
A. Switch-assisted balancing does not perform transmit load balancing
B. With Transmit load balancing all NICs in the team appear to have different MAC address
C. Only switch-assisted balancing uses a heartbeat for network integrity checks
D. With transmit load balancing you can team NICs that support different speeds

Answer: B
QUESTION NO: 23
Which Proliant family server line enclosure includes the licenses to use Rapid Deployment Pack (RDP)?
A. Proliant BL Server
B. Proliant DL server
C. Prolaint ML Server
D. Prolaint entry-level server
Answer: A
QUESTION NO: 24
When would you install vulnerability and patch management pack (PMP) and HP systems insight Manager
(SIM) on different servers in a distributed server environment?
A. When the hardware limitations would not allow HP SIM an VPM to function efficiently
B. When version control repository manager VCRM is also installed on HP SIM
C. When VPM needs to run on a Windows 2000 Server
D. When VPM needs to run on a Linux server
Answer: A
QUESTION NO: 25
Which protocols can systems use to send event information to HP systems insight manager? (Choose three.)
A. HTTP events
B. IP Address range
C. SSH on the CMS
D. WEBM indications
E. SNMP traps
Answer: A,D,E
QUESTION NO: 26
In which situation can vulnerability and patch acquisitions be run from the management (VPM) server?
A. When it has direct access to the internet or by using the Rapid Deployment server to support Packs
B. When it has direct access to the internet or by using the VPM acquisition utility installed on another system
C. When it has direct access to the HP software download site after registering for the updates

D. When it has direct access to the internet or by using the version control repository manager (CVRM) in HP
systems insight manager
Answer: B
QUESTION NO: 27
Which system does the Performance Management Pack (PMP) run on?
A. Each monitored server
B. Any non-SNMP client or server
C. The Central Management Server (CMS)
D. The client machine
Answer: C
QUESTION NO: 28
What can you do to gain greater security and reliability for iLO?
A. Install iLO Advanced Pack
B. Disable DNS/DHCP
C. Connect iLO to a dedicated management network
D. Enable iLO ROM-based setup utility (RBSU)
Answer: C
QUESTION NO: 29
The hardware status stored in the HP systems insight manager database is collected by polling which agents?
(Choose two.)
A. SNMP
B. Insight Manager Agent
C. SMIS Agent
D. DMI Agent
Answer: B,D
QUESTION NO: 30
Performance Management Pack (PMP) Provides powerful performance analysis tools to help manipulate the
stored performance data.
What does Data Extractor accomplish?

A. Generates an XML file that contains performance statistics from the database
B. Provides an easy method of deleting the recorded sessions for a logged server
C. Generates a summary report in HTML format
D. Enables playback of any monitored sessions recorded in the performance database
Answer: A
QUESTION NO: 31
What is the recommended size of a typical page file?
A. 1 to 2 times the size of the physical memory
B. 1.5 to 2 times the size of the physical memory
C. 3 to 4 times the size of the physical memory
D. 2 to 3 times the size of the physical memory
Answer: B
QUESTION NO: 32
Which cluster model is employed in the Microsoft Cluster Service (MSCS)?
A. Shared disk
B. Shared memory
C. Shared nothing
D. Shared everything
Answer: C
QUESTION NO: 33
Which Modular System Array (MSA) solution allows a maximum of eight connected MSA shelves?
A. MSA1500
B. MSA20
C. MSA1000
D. MSA500G2
Answer: A
QUESTION NO: 34
Which network components must be upgraded when upgrading your Ethernet network to a faster network?
(Choose three.)
A. The wiring to support faster network

B. All Network Interface Controllers (NICs)


C. All Fibre Channel Host Bus Adapters (HBAs)
D. All hubs and switches
E. Network Operating System (NOS)
F. All Cabling to 75 Ohm RGB-5 coax cabling
Answer: A,B,D
QUESTION NO: 35
Which statement best describes HP Proliant server availability?
A. The ability of redundant storage connections to ensure access to server data in case of a hardware failure
B. The ability of redundant network links to ensure access to the server during network outages
C. The ability of redundant power supplies to ensure access to the server during power outages
D. The ability of a system to maintain services despite hardware or software failures
Answer: D
QUESTION NO: 36
What is one difference between Transmit load balancing (TLB) and Switch-assisted load balancing?
A. Only switch-assisted balancing uses a heartbeat for network integrity checks
B. With transmit load balancing you can team NICs that support different speeds
C. With Transmit load balancing all NICs in the team appear to have different MAC address
D. Switch-assisted balancing does not perform transmit load balancing
Answer: C
QUESTION NO: 37
What is the primary objective of performance management pack (PMP)?
A. To monitor the network infrastructure
B. To monitoring 3rd party components
C. To monitor applications running on Proliant servers
D. To monitor Proliant hardware performance levels
Answer: D
QUESTION NO: 38
Certpaper.com wants to install several new servers but needs to incorporate a simplified cabl system which
proliant server series best meets this requirements?

A. ML Series
B. CL Series
C. BL Series
D. DL Series
Answer: C
QUESTION NO: 39
When does soft paging occur?
A. When a required page is not in memory because it is on the hard drive within the page file
B. When an application does not find a required page within its memory working set
C. When a required page is not in the page file on the hard drive
D. When an application can not find a required page in NVRAM
Answer: B
QUESTION NO: 40
When designing a reliable and highly available solution, what should you consider that might level of fault
tolerance? (Choose two.)
A. Cooling environment
B. Reliability
C. Scalability
D. Backup and maintenance time
E. Power Source (110 vs 220 v)
Answer: B,D
QUESTION NO: 41
When using Rapid Deployment Pack (RDP), why does HP recommend setting the primary lookup key to the
system serial number?
A. It makes HP management and foundation agents easier to deploy
B. It avoids duplicate database entries that might occur with severs with two or more NICs
C. It allows you to create new images specific to your environment for both new and managed machines
D. It allows the deployment server to specify an alias
Answer: B
QUESTION NO: 42
Which level of replication does HP OpenView Storage Mirroring provide?

A. Bit-level
B. File-level
C. Directory-level
D. Byte-level
Answer: D
QUESTION NO: 43
When making changes in the data collection interval of HP SIM, what is the next step to make the changes
effective?
A. Restart SNMP
B. Shutdown server
C. Restart HP SIM server
D. Restart HP Management Agents
Answer: D
QUESTION NO: 44
What is the recommended size of a typical page file?
A. 3 to 4 times the size of the physical memory
B. 2 to 3 times the size of the physical memory
C. 1 to 2 times the size of the physical memory
D. 1.5 to 2 times the size of the physical memory
Answer: D
QUESTION NO: 45
Which utility supports the configuration of Virtual Local Area Network (VLAN) on NICs and NIC teams?
A. HP Network options in Control Panel
B. Network Configuration Utility
C. ROM Base Setup Utility RBSU
D. Performance Management Pack (PMP)
E. Smartstart CD
Answer: B
QUESTION NO: 46

What is the highest availability Level that you can achieve using only a HP ProLiant DL380 server with no
additional or optional storage components?
A. Availability Level 4
B. Availability Level 1
C. Availability Level 2
D. Availability Level 5
E. Availability Level 3
Answer: C
QUESTION NO: 47
What must be done to enable ILO advanced features on a BL p-class server?
A. Nothing; it is already enabled
B. Install the insight manager Agents
C. Enter the activation key
D. When starting RBSU, press CTRL-A
Answer: A
QUESTION NO: 48
What is the default listening port for the RDP (Rapid Deployment Pack) server?
A. 280
B. 2301
C. 2381
D. 402
Answer: D
QUESTION NO: 49
Which shared storage solution is used by the HP Proliant Packaged Cluster and is end-to-end SCSI-based?
A. MSA500
B. MSA30
C. MSA15000
D. MSA1000
Answer: A
QUESTION NO: 50

Where is the Integrated Management (ILM) Log stored?


A. RAM
B. NVRAM
C. ROM
D. System partition
Answer: B
QUESTION NO: 51
To resolve a processor bottleneck, due to serial task processing, what is the best performance?
A. Add faster disk subsystem
B. Upgrade to faster processors
C. Add additional memory
D. Add additional processors
Answer: B
QUESTION NO: 52
Which plan is considered to be a scale-out action plan?
A. Distributing computing or clustering
B. Adding additional processors
C. Adding Memory
D. Adding faster disk subsystems
Answer: A
QUESTION NO: 53
When using HP SIM through a firewall, which protocols are recommended? (Choose three.)
A. HTTPS
B. DMI (Desktop Management Interface)
C. WBEM
D. SNMP
E. SSH (Secure Shell)
Answer: A,C,E
QUESTION NO: 54
Which control panel applet changes the SNMP Data collector interval of the agents at the monitoring server?

A. HP Network
B. Administrative Tools
C. HP Management Agents
D. Automatic Updates
Answer: C
QUESTION NO: 55
What is HP's availability clustering solution in a Proliant/Linux environment?
A. TruCluster
B. Serviceguard
C. Beowulf Cluster
D. Linux Server Cluster Service (LSCS)
Answer: B
QUESTION NO: 56
Which statement best describes HP Proliant server availability?
A. The ability of redundant storage connections to ensure access to server data in case of a hardware failure
B. The ability of redundant power supplies to ensure access to the server during power outages
C. The ability of redundant network links to ensure access to the server during network outages
D. The ability of a system to maintain services despite hardware or software failures
Answer: D
QUESTION NO: 57
Which operating system must be installed before installing vulnerability and Path Management (VPM) on a HP
systems insight manager (HP SIM) console?
A. Either Linux or HP-UX
B. Linux
C. HP-UX
D. Windows
Answer: D
QUESTION NO: 58
Which Proliant essentials software helps discover performance bottlenecks during the site survey portion of
Certpaper.com needs analysis?

A. Workload Management Pack (WMP)


B. Performance Management Pack (PMP)
C. Rapid Deployment Pack (RDP)
D. HP Systems Insight Manager (SIM)
Answer: B
QUESTION NO: 59
What are the leading industry standard technologies that HP ProLiant Essentials Vulnerability Management
Pack (VPM) is based on? (Choose two.)
A. Microsoft Operations Manager (MOM) for Windows Operating systems
B. HP Openview management suite using Radia patch management technology
C. HP systems insight manager (SIM) version control repository manager technology
D. Ignite-UX Graphical Interface (GUI) technology
E. Harris Security Threat Avoidance technology (STAT) scanning technology
Answer: B,E
QUESTION NO: 60
Which statement is true regarding an HP SIM managed system?
A. A managed system can be any device on the network that can communicate with SIM
B. Hubs and routers are not considered as managed systems
C. Only the CMS can be managed system
D. A managed system can't be managed by more than on CMS (Central Management Server)
Answer: A
QUESTION NO: 61
You previously disabled iLO in ROM-based Setup Utility (RBSU) what must be reconfiguration from the host?
A. Enable iLo RBSU in the Global settings
B. set the iLO Security override switch
C. Reboot the server and re-enable iLO access in the serer RBSU
D. Select Reset Defaults in the Global Settings
Answer: B

Topic 2, Practice (140 Questions)

Use these to reinforce exam concepts

QUESTION NO: 1
Where are standard system messages stored in a Linux Server?
A.
B.
C.
D.

/var/log/messages
/etc/standard/messages
/proc/messages
/root/system/messages

Answer: C

QUESTION NO: 2
You deploy 20 DL380 G4 servers running Windows 2003 over several months. Once complete, you have
many different ProLiant Support Pack version levels. You identify one server you wish to use a baseline
server to which all other servers must conform. Which tool will help you do this?
A.
B.
C.
D.

Microsofts Windows Update Server


Performance Management pack(PMP)
Version Control Repository Manager(VCRM)
Vulnerability and Patch Management Pack(VPM)

Answer: C

QUESTION NO: 3
Exhibit: ** Missing ***
After installing the HP Insight Agents on a HP ProLiant, you launch servers web agents home page. Why
does the page not display the subsystem information
A.
B.
C.
D.

The Insight Agents may not have been started.


The IIS service has not been started.
The SNMP Community string is not properly configured.
The local Administrator account does not have the necessary privileges.

Answer: C

QUESTION NO: 4
Which command provides information on cpu time, processes, and memory statistics on a Linux server?
A.
B.
C.
D.

nfsstat
cpustat
vmstat
netstat

Answer: C

QUESTION NO: 5
Which HP System Insight Manager functionality will assist you in managing a Microsoft Virtual Server
running on an HP ProLiant server?
A.
B.
C.
D.

Virtual Machine Management (VMM)


Microsoft Virtual Machine plug-in for HP SIM
Performance Management Pack(PMP)
Version Control Respository Manager (VCRM)

Answer: A

QUESTION NO: 6
Exhibit: ** Missing ***
What does symbol represent in the performance column of HP SIM?
A.
B.
C.
D.

The servers subsystem is approaching a bottleneck condition


The server is not supported
The server is not licensed
The server is offline due to a system bottleneck

Answer: A

QUESTION NO: 7
You are using the Virtual Media Capability of the iLO interface to install software on a server. During the
installation, you notice an issue in using the high Performance Mouse.
What can you do to activate the high Performance Mouse functionality?
A. Reinstall the Java Virtual Machine and then restart the browser to establish High Performance Mouse
functionality
B. Nothing, High Performance Mouse functionality is not supported when using Virtual Media
functionality
C. You must enable the High performance Mouse after initiating the Virtual Media session
D. You must enable the High Performance Mouse prior to initiating the Virtual media session
Answer: D

QUESTION NO: 8
How can the Version Control Repository Manager be updated? (Select three)
A.
B.
C.
D.
E.

automatic update direct from HP via internet


from the firmware and maintenance CD
from the management CD
manually download from the HP Support & Drivers website
manually copy the catalog from another server and rescan the catalog

Answer: A, D, E

QUESTION NO: 9
Which Cluster Monitor Settings pages I HP Systems Insight Manager are used to set cluster operational
parameters? (Select two)
A.
B.
C.
D.
E.

Cluster Settings
Node Settings
Cluster Resource Settings
Node Resource Settings
Optimize Settings Page

Answer: C, D

QUESTION NO: 10
Certpaper.com has an application that runs on the same server as his SQL Server. He suspects the
application of leaking memory but needs to keep the application on the SQL Server.
Which HP tool can you recommend to help prevent a memory leaking application from stealing precious
SQL Server memory resources?
A. Use VMWare to create two virtual machines on the server, one for SQL and one for the rogue
application.
B. Use Resource Partitioning Manager (RPM) to isolate the application and limit the resources available to
it.
C. Use AWE enable on the SQL Server t protect the memory allocated to the SQL Server application.
D. Use HP System Insight Manager to identify the overburdened subsystem and flush the memory registers
Answer: B

QUESTION NO: 11
In Linux, which command will show the system IRQ assignments and the devices that are using those
IRQs?
A.
B.
C.
D.

cat/proc/ioports
cat/proc/bus
cat/proc/devices
cat/proc/interrupts

Answer: D

QUESTION NO: 12
Certpaper.com wants to upgrade five 18GB hard derives to 72GB hard drives without downtime on their
SA5302. What is the first step you should take when performing online Array Capacity Expansion?
A. Insert the 5 72GB drives and migrate the data in the Online Raid Configuration for Arrays (ORCA)
B. Remove one 18GB hard drive at a time and replace with 72GB hard drive.

C. Remove one 18GB hard drive and replace it with a 72GB drive.
D. Back up all data to minimize the risk of losing data.
Answer: D

QUESTION NO: 13
Which MSA product supports SATA drives in a SAN environment?
A.
B.
C.
D.

MSA1000
. MSA500
. MSA30
. MSA1500

Answer: D

QUESTION NO: 14
On an Msa1000 configured with a single MSA Switch 2/8, how may servers can be connected to the
MSA1000?
A.
B.
C.
D.

2
7
4
8

Answer: B

QUESTION NO: 15
What is the airflow direction in the rack-mountable HP Proliant servers?
A.
B.
C.
D.

front to back
back to front
top to bottom
bottom to top

Answer: A

QUESTION NO: 16
Which HP ProLiant Essentials tool detects and analyzes hardware bottlenecks on HP Proliant Servers?
A.
B.
C.
D.

Virtual Machine Management Pack


Performance management Pack
HP Systems Insight manager
Vulnerability and Patch Management Pack

Answer: B

QUESTION NO: 17
You are consulting with Certpaper.com on the advantages of consolidating his aging datacenter servers
into a HP BladeSystems solution.
What are the most important environment variables to consider? (Select two)
A.
B.
C.
D.
E.

cooling
sound
power
installation and support options
serviceability

Answer: A, C

QUESTION NO: 18
Which HP Proliant server family has been designed to run on 48V DC power?
A.
B.
C.
D.

BL family
DL family
ML family
CL family

Answer: A

QUESTION NO: 19
You want to submit a Bill of Materials (BOM) with your proposal for implementing a p-Class HP
BladeSystem.
Which utilities will help to builds your solution and BOM? (Select two)
A.
B.
C.
D.
E.

HP Consolidation tool
HP Enterprise Configurator
Rack/site installation preparation Utility
HP Custom Builder
HP BladeSystem sizing Utility

Answer: B, E

QUESTION NO: 20
Which HP tool can help you configure and size a ProLiant server to suit specific business needs?
A.
B.
C.
D.

ProLiant Essentials Foundation Pack


Enterprise Configurator
ProLiant Essentials Workload Management Pack
ProLiant Support Packs

Answer: B

QUESTION NO: 21
Certpaper.com requires the highest level of memory protection available in a server with the lowest
additional memory overhead.
Which technology should you recommend?
A.
B.
C.
D.

RAID memory
Online spare memory
Hot-plug mirrored memory
Single board mirrored memory

Answer: A

QUESTION NO: 22
Which HP Storage Area Network (SAN) attached storage can be configured using the Array
Configuration Utility (ACU) running on an HP ProLiant server with Linux?
A.
B.
C.
D.

MSA 1000
MSA 500
MSA 30
EVA 3000

Answer: A

QUESTION NO: 23
Which enterprise class ProLiant server is ideal for server density while minimizing power consumption?
A.
B.
C.
D.

BL Servers
DL Servers
ML Servers
CL Servers

Answer: A

QUESTION NO: 24
Certpaper.com has a team of engineers determining if their server infrastructure is underutilized.
Which ProLiant Essentials Pack should you recommend to analyze the utilization of the servers?
A.
B.
C.
D.
E.

Rapid Deployment Pack


Virtual Machine Management Pack
Performance Management Pack
Insight Diagnostics
Integrated Light-Out Advanced Pack

Answer: C

QUESTION NO: 25
Which ProLiant Essentials Software does HP recommend to use during the site survey portion of
Certpaper.com needs analysis?
A.
B.
C.
D.

Rapid Deployment Pack


Virtual machine management Pack
Performance Management Pack
Integrated Lights-Out Advanced Pack

Answer: C

QUESTION NO: 26
Which statement describes the function of a SCSI Bridge? (Select two)
A.
B.
C.
D.
E.

It allows remote users local access to HP supported backup solutions.


It allows IP hosts transparent access to intelligent storage arrays using iSCSI protocol.
It provides ability to off-load IP routing from a router to an HP Enterprise Gigabit Switch.
It provides universal access to storage over IP network.
It allows SCSI-based access to Fibre Area NetWorks.

Answer:B, D

QUESTION NO: 27
Which online tool can be used to view boot events, hardware configuration and driver versions?
A.
B.
C.
D.

Integrated Management Log (IML)


Registry and Event Logs
Insight Diagnostics
SmartStart

Answer: C

QUESTION NO: 28
The Proliant Essentials Vulnerability and Patch Management Pack integrates with which HP product?
A.
B.
C.
D.

Rapid Deployment Pack


Systems Insight Manager
Workload Management Pack
Integrated Administrator

Answer: B

QUESTION NO: 29
Which file-names are used by default by the Smart Start Scripting Tool?
A.
B.
C.
D.

server.hwr, server.ary, server.rlo, unattend.txt


rdeploy.exe, script.bat, config.sys, system.ini
config.sys, boot.ini, system.ini, ssst.bat
autoexec.bat, config.sys, rdeploy.exe, unattend.txt

Answer: A

QUESTION NO: 30
What type of paging should prevented whenever possible by adding memory?
A.
B.
C.
D.

soft paging
serial paging
hard paging
parallel paging

Answer: C

QUESTION NO: 31

Certpaper.com has a ProLiant DL580G2 with a SA6400 running windows 2003 connected two external
4354 storage enclosures. Each 4354 storage enclosure has 14 x 72GB hard drives. Certpaper.com has been
experiencing hard drive failures in these 4354 storage enclosures.
Which tools can you use to get more detailed information about these failures? (Select two)
A.
B.
C.
D.
E.

HP Integrated Management Log (IML)


Array Diagnostic Utility (ADU)
Array Configuration Utility (ACU)
Options Rom Configuration for Arrays (ORCA)
Integrated Remote Consol

Answer: A, B

QUESTION NO: 32
Certpaper.com is connected that their web-based customer survey program is performing slowly.
Which HP Storage is best suited for their high I/O bandwidth application?
A.
B.
C.
D.

A SAN based modular Storage Array with one controller and several disks.
A SCSI based Modular Storage Array directly attached with multiple controllers.
Local disk attached to the integrated SCSI controller.
A NAS with a few larger disks

Answer: A

QUESTION NO: 33
Which business continuity solutions can HP Services provide as part of Certpaper.coms disaster recovery
plan? (Select three)
A.
B.
C.
D.
E.

Continuity plan testing through simulated disaster scenarios.


HP hosted and outsourced host-site recovery locations.
HP underwritten disaster insurance.
Data replication software and hardware.
Professional services for all phases of a planning program.

Answer: B, D, E

QUESTION NO: 34
Certpaper.com has a ProLiant server that is crashing with a Windows blue screen error. While Windows
is writing a complete memory dump the server is automatically rebooting, which is corrupting the
memory dump.
How does Certpaper.com stop the server from automatically rebooting to enable windows to finish
writing the memory dump?
A.
B.
C.
D.

Disable Automatic Server Recovery (ASR).


Enable Automatic Server Recovery (ASR).
Disable HP Systems Insight Manger.
Disable Rack and Power manager.

Answer: A

QUESTION NO: 35
ProLiant Essentials Performance Management Pack enables remote data collection. Where can the
logged data manipulation and report generation be performed?
A.
B.
C.
D.

the performance analysis server


the Version Control repository server
the HP Systems Insight Manager Console
HP System Management Homepage

Answer: A

QUESTION NO: 36
Which method you should use to reset the local administrator password of the iLO management
controller for ProLiant server without having to reboot the server?
A.
B.
C.
D.

ROM Based Setup Utility


CPQLOCFG with the change_password.XML_script
HPQONCFG with the administrator_Reset_PW.XML_script
Connect using Terminal Services and use the iLO configuration utility

Answer: C

QUESTION NO: 37
What is the difference between the online version and offline version of Insight Diagnostics?
A. The online and offline versions of Insight Diagnostics have the same features but are run from different
places.
B. The online version of Insight Diagnostics runs Survey while the offline version tests all the sub-systems.
C. The online version can test everything but the disk subsystem while the offline version can test all the
sub-systems.
D. The online version can test everything but the memory while the offline version can test all the subsystems.
Answer: B

QUESTION NO: 38
What functionality does the Rapid Deployment Pack SIM Integration Module provide?
A.
B.
C.
D.

view and deploy un deployed servers from within HP Systems Insight Manager
manually send RDP jobs to managed servers from within HP Systems Insight Manager
view and manage SNMP alerts from within the RDP Deployment Console
schedule RDP jobs for managed servers from within HP System Insight Manager

Answer: A

QUESTION NO: 39
What are features of HP OpenView Storage Virtual Replicator? (Select two)
A.
B.
C.
D.
E.

It allows users to create on-demand allocated snapshots.


It allows users to create fully allocated snapshots.
It allows users to clone a virtual disk from one host to another host
It allows consolidation of physical storage into pools of capacity.
It allows remote replication of basic disks on windows platforms.

Answer: A, D

QUESTION NO: 40
When deploying software patches from a repository that does not reside on the HP Systems Insight
Manager server, what condition must the Version Control Repository Manager (VCRM) meet?
A.
B.
C.
D.

it must have execute rights.


It must be trusted to HP System Insight Manager.
It must have administrator rights.
It must be trusted to the domain

Answer: B

QUESTION NO: 41
Which software allows a single server to be cabled on two independent buses t an MSA1000 storage
system providing multi-path and failover functionality?
A.
B.
C.
D.

HP Smart Array Multipath


Selective Storage Presentation
HP StorageWorks Secure Path
HP StorageWorks Auto Path

Answer: C

QUESTION NO: 42
What is required on every subnet when configuring a distributed deployment solution of Rapid
Deployment Pack?
A.
B.
C.
D.

deployment consol
file server
SQL database
PXE server

Answer: D

QUESTION NO: 43
Certpaper.com is using HP OpenView Storage Mirroring and then decides to create a cluster. Storage
Mirroring does not recognize the cluster.
What must be done to correct the problem?
A.
B.
C.
D.

Upgrade the Storage Mirroring installation.


Connect to windows Update to download the latest dlls.
Install the latest ProLiant Support pack.
Uninstall and reinstall the cluster.

Answer: A

QUESTION NO: 44
What is a requirement to access the HP Systems Insight Manager 4.X browser interface from a client?
A.
B.
C.
D.

Microsoft .Net Framework 1.1


HTTP 1.1
Java Runtime Environment
ActiveX control

Answer: C

QUESTION NO: 45
Certpaper.com using blade servers and Rapid Deployment Pack wants the blades to be processed
automatically when they are discovered by the Deployment Console.
Where can this be configured?
A.
B.
C.
D.

Altiris client agent properties


New Computers group properties
PXE Configuration Utility
Bootworks

Answer: C

QUESTION NO: 46
What is a feature of HP OpenView Storage Virtual Replicator?
A.
B.
C.
D.

It allows remote disk cloning from host to host


It allows cross-node mirroring
It allows online growth of the shared storage capacity
It allows making snapclones across storage pools

Answer: C

QUESTION NO: 47
You have a ProLiant DL580 G2 running windows 2003 Server. You have removed the physical disks and
placed them in an MSA1000.
Which utilities should you use to configure the external boot from the MSA1000? (Select two)
A.
B.
C.
D.
E.

Array Configuration Utility(ACU)


Online ROM Configuration for Arrays (ORCA)
ROM Based Setup Utility (RBSU)
System Configuration Utility (SCU)
HBA BIOS configuration utility

Answer: C, A

QUESTION NO: 48
What is the minimum database configuration for Certpaper.com with fifty HP ProLiant servers wanting
to implement HP Systems Insight Manager?
A.
B.
C.
D.

HP Systems Insight Manager using MSDE on a different server


HP Systems Insight Manager using SQL Server on a different server
HP Systems Insight Manager using SQL Server on the same server
HP Systems Insight Manager using MSDE on the same server

Answer: D

QUESTION NO: 49
Certpaper.com wants to deploy HP BladeSystem server using Rapid Deployment Pack Linux Edition
(RDP-LE). Which database must be in place on the deployment server before RDP-LE is installed?
A.
B.
C.
D.

Ingres
PostgreSQL
Open SQL
MSDE

Answer: B

QUESTION NO: 50
Which layer of Systems Insight Manager is responsible for the storage of all discovered data on the
network?
A.
B.
C.
D.

Web Browser interface Layer


Version Control Repository Layer
Desktop Agent Layer
Central Management Server Layer

Answer: D

QUESTION NO: 51
Certpaper.com is installing HP Systems Insight Manager. They want to keep the database on an HP-UX
server. Which database is supported?
A.
B.
C.
D.

Sybase
Ingres
Oracle
PostgreSQL

Answer: D

QUESTION NO: 52
What is the name of the optional battery modules that increase the availability of battery backup time in
case of power failure on an HP UPS?
A.
B.
C.
D.

wireless paralleling modules


extended runtime modules
UPS extension modules
Advanced power backup modules

Answer: B

QUESTION NO: 53
What identifies a Host Bus Adapter on a Fibre Channel fabric?
A.
B.
C.
D.

MAC address
World Wide Name (WWN)
Node Name
Serial Number of the HBA

Answer: B

QUESTION NO: 54
In order t minimize performance degradation to the end user community in the event of a disk failure in
an array, what can be done to increase performance?
A.
B.
C.
D.
E.

Use the ACU to change the Rebuild priority to high


Update the Smart Controller firmware.
Use ORCA to change the Rebuild priority to low
Use the ACU to change the Rebuild priority to low
Use ORCA to change the Rebuild priority to high

Answer: D

QUESTION NO: 55
What can be used to calculate the power requirements for a rack with different HP ProLiant servers
when additional memory, processors, and storage are added to the system?
A.
B.
C.
D.

HP ESS Power Sizer


HP ProLiant Power Calculator
HP Custom Power Assistance
HP ProLiant Configurator

Answer: B

QUESTION NO: 56
Which primary lookup key does the installation recommend when installing Rapid Deployment Pack
(RDP) Windows Edition version 2.0?
A.
B.
C.
D.

SSID
UID
Serial Number (SMBIOS)
MAC Address

Answer: C

QUESTION NO: 57
A DL580G2 running Linux boots from the internal SmartArray storage with one logical disk and also has
one MSA1000 Logical Unit (LUN) configured.
How will those disks appear as Linux devices?
A. The SmartArray disk will appear as /dev/cciss/c0d0p1 and the MSA1000 disk will appear as/dev/sda
B. The SmartArray disk will appear as /dev/sda and the MSA1000 disk will appear as/dev/spm/dev0.
C. The SmartArray disk will appear as /dev/cciss/c0d0p1 and the MSA1000 disk will appear
as/dev/cciss/c1d0p1.
D. The SmartArray disk will appear as /dev/sda and the MSA1000 disk will appear as/dev/sdb
Answer: A

QUESTION NO: 58
Where would you insert the /3GB switch setting to take advantage of 3GB of Ram for your applications
on a Windows 2000 Advanced Server?
A.
B.
C.
D.

Windows Registry
System Control Panel applet
Boot.ini
Autoexec.nt

Answer: C

QUESTION NO: 59
What is the best RAID solution for an Enterprise customer?
A.
B.
C.
D.

SCSI based RAID


IDE based RAID
SATA based RAID
iSCSI based RAID

Answer: A

QUESTION NO: 60
Which processor is the only full featured 64-bit processor and not x86 Extended?
A.
B.
C.
D.

EM64T
Opteron
AMD 64
Itanium

Answer: D

QUESTION NO: 61

What changes can be made to increase performance for a read intensive application server?
A.
B.
C.
D.

Use ROM Based Setup Utility(RBSU) to change the cache to write Back cache.
Use Array Configuration Utility (ACU) to change the cache to write Back cache
Use Online Configuration for Raid Arrays (ORCA) to change the Read/Write ratio to 90/10
Use the Array Configuration Utility (ACU) to change the Read/Write ratio to 90/10.

Answer: D

QUESTION NO: 62
In a G4 server, which memory technology offers the best performance?
A.
B.
C.
D.

SDRAM
DDR
DDR2
RDRAM

Answer: C

QUESTION NO: 63
When designing a solution that addresses a Mission Critical requirement for an enterprise customer,
what should be considered as the key success factor in the design?
A.
B.
C.
D.

availability or backup services from a local highly available cluster set


redundancy and protection of replicated data set across multiple sites
failover-failback with manual restart capability of highly available cluster set
frequency of data set backup to tape library during operation hours

Answer: B

QUESTION NO: 64
Which step needs to be completed before you can enable virtual media and graphical consol iLO
functionality on a ProLiant DL580 G2?

A.
B.
C.
D.

Enable it in the ROM Based Setup Utility (RBSU) advanced options page.
Enter the integrated Lights Out Advanced Pack activation key.
Enable administrator privileges in the Security tab.
Update the iLO firmware to a version that supports it.

Answer: B

QUESTION NO: 65
HP ProLiant Servers support Oracle 9i RAC solution. This RAC solution is also known as_________.
A.
B.
C.
D.

Redundant Array Cluster


Parallel Database Cluster
Nonstop Array Database
Shared File Database Cluster

Answer: B

QUESTION NO: 66
Which installation file must be run to install the Linux ProLiant Support Pack (PSP) on a Linux server
using Smart Start 7.xx?
A.
B.
C.
D.

installtxx.sh
installtxx.rpm
installtxx.bat
installtxx.bat

Answer: A

QUESTION NO: 67
Certpaper.com wants to backup data once a week and then backup only the changes since the last backup
on all other days.
Which backup strategy does this represent?

A.
B.
C.
D.

copy backup and incremental


copy backup and differential
full and incremental
full and differential

Answer: C

QUESTION NO: 68
You are installing HP Systems Insight Manager (HP SIM) in a Linux environment. Which database is
required for the Central Management Server (CMS)?
A.
B.
C.
D.

Ingres
MySQL
Open SQL
PostgreSQL

Answer: D

QUESTION NO: 69
What are the three levels of trust configurations available between the Version Control Agent and the
Central Management Server? (Select Three)
A.
B.
C.
D.
E.

trust all
trust by name
trust by IP address
trust by certificate
trust by private key

Answer: A, B, D

QUESTION NO: 70
You have extended a logical drive using the Array Configuration Utility.
Which Windows 2003 utility should use to extend the partition of a basic disk in Windows?

A.
B.
C.
D.

Disk Management
HP online Volume Growth
Storage MMC
Fdisk

Answer: B

QUESTION NO: 71
Which repositories can the default installation of Version Control Repository Manager (VCRM) manage?
A.
B.
C.
D.

All repositories that are located on the network


A single repositories that are located on the network
Repositories that are located on the server on which VCRM is installed.
Repositories that are located on the server on which VCRM is installed

Answer: C

QUESTION NO: 72
You have extended a logical drive using the Array Configuration utility. Which Windows 2003 utility
should you use to extend the partition of a basic disk in Windows?
A.
B.
C.
D.

Disk Management
HP Online Volume Growth
Storage MMC
F disk

Answer: B

QUESTION NO: 73
How can the HP One-Button Disaster Recover (OBDR) be configured?
A. by pressing F9 during post and following the instructions
B. by pressing F8 during post and following the instructions

C. by pressing F10 during post and going into the advanced configuration menu
D. by pressing F2 during post and going into the advanced configuration menu
Answer: B

QUESTION NO: 74
HP Systems Insight Manager has ability to restrict where users log in based on what resource?
A.
B.
C.
D.

MAC Address
IPX Address
IP Address
Hostname

Answer: C

QUESTION NO: 75
You are installing HP Systems insight Manager (HP SIM) in a Linux environment. Which database is
required for the Central Management Server (CMS)?
A.
B.
C.
D.

Ingres
MYSQL
Open SQL
PostgreSQL

Answer: D

QUESTION NO: 76
Which network protocol does the Version Control Agent use to communicate with Systems Insight
Manager after a deployment task occurs?
A.
B.
C.
D.

HTTP
SNMP
DMI
TFTP

Answer: A

QUESTION NO: 77
Exhibit:
L-drive has 4 disks with raid 1+0 and average queue time is 14.
S-drive has 16 disks with raid 5 and average queue time is 16.
Certpaper.coms database is placed on a SA5302 with 18 drives. The DBA states that transaction response
is slow. Windows performance monitor displays the Disk Queue Length for drives L: and S: as shown in
the exhibit. What can be done to improve database performance?
A.
B.
C.
D.

Increase the size of the page file.


Add drives to the Raid 1+0 set holding the SQL logs (drive l:).
Add drives to the Raid 5 set holding the SQL tempdb (drive c:).
Add drives to the Raid 5 set holding the SQL data (drive s:).

Answer: B

QUESTION NO: 78
Which HP ProLiant Essentials software assists you in eliminating Trojan horses, worms, and viruses on
HP ProLiant servers?
A.
B.
C.
D.

Virtual Machine Manager pack


Vulnerability and patch Management pack
Performance Management pack
Version Control Repository Manager

Answer: B

QUESTION NO: 79
Exhibit: Yellow Icon
What does the symbol represent in the performance column of HP SIM?

A.
B.
C.
D.

The servers subsystem is approaching a bottleneck condition.


The server is not supported.
The server is not licensed.
The server is offline due to a system bottleneck.

Answer: A

QUESTION NO: 80
Certpaper.com wants to know the amount of free disk space available on a Linux server on each file
system. Which command will give the customer the necessary information?
A.
B.
C.
D.

hdparm
nfsstat
df
fatab

Answer: C

QUESTION NO: 81
While monitoring your HP ProLiant server on your Linux client, you attempt remote console into the
server and your browser only displays a red X. why?
A.
B.
C.
D.

The only supported browser is Microsofts Internet Explorer.


The Mozilla browser requires the correct java plug-in.
The Microsoft internet Explorer for Linux requires the java plug-in.
The browser must be allowed to accept cookies

Answer: B

QUESTION NO: 82 DRAG DROP


Match the ProLiant Essentials value added software with its function. (Note: you will have one extra
function.)

Exhibit: *** MISSING ***


Answer:
Explanation: Pending. Send your suggestion to feedback@Certpaper.com

QUESTION NO: 83
What is the HP recommended method of interfacing with an HP ProLiant server through iLO from a
Linux client?
A.
B.
C.
D.

the web GUI interface


the command line interface
the RIBCL
the ilostat utility

Answer: B

QUESTION NO: 84
An SA5304 has 28 physical drives configured in a single RAID 6 volume.
What should be the maximum physical disk queue length for this volume?
A.
B.
C.
D.

2
14
28
56

Answer: D

QUESTION NO: 85
One of the must important for service engineers on a Linux server captures machine check logout frames.
Which file is it?
A.
B.
C.
D.

Nar/log/frames
Nar/log/messages
Nar/log/logout
Nar/log/errors

Answer: B

QUESTION NO: 86
In HP Systems Insight Manager, several servers have the Sw column marked with the blue?. What
needs to occur in order to allow proper communication with SIM?
A. Establish a Trust Relationship between the target servers and the SIM server
B. Establish a forest level Trust Relationship between the target servers domain and the SIM servers
domain.
C. Run Software Discovery on the SIM server
D. Configure the ProLiant Support pack web agent components to trust all.
Answer: A

QUESTION NO: 87
Certpaper.com wants to know what type of processor is in their Linux server. Which command on a
Linux server will give you information about the type of processor?
A.
B.
C.
D.

less /proc/cpustat
less /proc/cpuinfo
less /proc/processor
less /proc/host

Answer: B

QUESTION NO: 88
Which HP Storage Area Network (SAN) attached storage subsystem is compatible with 2 Gb/s Fiber
Channel interconnect arbitrated loop (AL) hubs?
A.
B.
C.
D.

MSA 1000
MSA 1500
MSA 30
EVA 3000

Answer: A

QUESTION NO: 89
What is the name of the optional external battery mobile that increases the total available tome on an HP
Uninterruptible power Supply (UPS)?
A.
B.
C.
D.

extended runtime modules


unity power rated battery
wireless paralleling modules
enhanced battery modules

Answer: A

QUESTION NO: 90
Which protocol is used to collect detailed operating system level information from Windows servers?
A.
B.
C.
D.

SNMP
PPTP
WMI
WBEM

Answer: C
QUESTION NO: 91
HP ProLiant DL servers are_____.Select TWO.
A.
B.
C.
D.
E.

designed to include more embedded features per unit of space


designed for remote and branch office environments
optimized for maximum internal system expansion
optimized for density-stacking many servers in a rack
designed for centralized storage

Answer: A, D

QUESTION NO: 92
You are working with Certpaper.com who requires a centrally managed, highly-available and scalable
storage solution for their multiserver datacenter application. Which technology should you incorporate
into your solution.
A.
B.
C.
D.

Direct Attached Storage (DAS)


Network Attached Storage (NAS)
Storage Area Network (SAN)
Network File System (NFS)

Answer: C

QUESTION NO: 93
Your customer is concerned with the heat distribution of the additional HP ProLiant DL380 G4 servers
that you have proposed. Which HP tool can you use during the planning phase to address the concern?
A.
B.
C.
D.

Workload Management pack


ProLiant P-Class Sizing Utility
ProLiant Power Calculator
HP Enterprise Configurator

Answer: C

QUESTION NO: 94
You are developing a P-Class HP BladeSystem solution for Certpaper.coms datacenter. Which utility
provides you with the total volt-amp requirements, total system BTU /hr, and total system weight of your
proposed solution?
A.
B.
C.
D.

rack/site installation preparation utility


HP BladeSystem sizing utility
HP Custom Builder
HP Enterprise Configurator

Answer: B

QUESTION NO: 95
Certpaper.com is looking to upgrade their solution. They require the new solution to have increased
storage capacity, faster transfer rates, and backward compatibility with their current solution. The
customer currently has standalone DLT tape drives. Which tape technology should you recommend?
A.
B.
C.
D.

Digital Audio Tape (DAT)


Advanced Intelligent Tape (AIT)
Super Digital Linear Tape (SDLT)
Ultrium

Answer: C

QUESTION NO: 96
Which HP ProLiant server comes standard with the integrated Lights Out (iLO) Advanced pack?
A.
B.
C.
D.

BL 10e
DL 380
DL 145
BL 20p

Answer: D

QUESTION NO: 97
Your client wishes to implement a regular data back-up schedule but cannot take their volumes off-line.
Which tool should you recommend?
A.
B.
C.
D.

HP StorageWorks Secure path


HP Enterprise configurator
HP StorageWorks Virtual Replicator
HP StorageWorks Backup Sizing Tool

Answer: C

QUESTION NO: 98
The Offline Analysis Tool is similar to the online version of performance Management pack. Which file
type does the Offline Analysis Tool read?
A.
B.
C.
D.

ASCll
CSV
PDF
XML

Answer: D

QUESTION NO: 99
Which tool should you use to design an HP Enterprise Backup Solution?
A.
B.
C.
D.

StorageWorks Sizing Tool


Library & Tape Tools
Extended Runtime Configuration Tool
Custom Builder

Answer: A

QUESTION NO: 100


Certpaper.com installs a cluster on the network. The nodes are discovered and managed by HP Systems
Insight Manager but the Cluster is not. What should be done to correct the problem?
A. Upgrade the firmware on the cluster nodes.
B. Manually add the IP address of the cluster to HP Systems Insight
a. Manager.
C. Enable cluster discovery in HP Systems Insight Manager.
D. Activate the clustering Information agents.
Answer: D

QUESTION NO: 101


What are the correct statements regarding HP OpenView Storage Virtual Replicator? Select Two.
A.
B.
C.
D.
E.

It allows expansion of dynamic disks on Windows platforms.


It is a server-based virtualization technology.
It is a controller-based virtualization technology.
It allows expansion of virtual disks on Linux platforms.
It allows expansion of basic disks on Windows platforms.

Answer: B,E

QUESTION NO: 102


When performing a manual discovery in HP Systems Insight Manager, Which file is used to import
multiple devices into the database?
A.
B.
C.
D.

hostname
Imhosts
Hosts
Networks

Answer: C

QUESTION NO: 103


What level of security must your web browser be set to in order for HP Systems Insight Manager to work
properly?
A.
B.
C.
D.
E.

block all cookies


accept all cookies
medium
high
low

Answer: B

QUESTION NO: 104


Which utility provides dual-path functionality and supports failover capability for redundant HBAs in a
server with redundant cabling to an MSA500 system?
A.
B.
C.
D.

HP StorageWorks Secure path


HP Smart Array Multipath Software
Selective Storage Presentation
HP StorageWorks Auto path

Answer: B

QUESTION NO: 105


What is the minimum database configuration for Certpaper.com with fifty HP ProLiant servers wanting
to implement HP Systems Insight Manager?
A.
B.
C.
D.

HP Systems Insight Manager using MSDE on a different server


HP Systems Insight Manager using SQL Server on a different server
HP Systems Insight Manager using SQL Server on the same server
HP Systems Insight manager using MSDE on the same server

Answer: D

QUESTION NO: 106


After creating a new repository in Version Control Repository Manager (VCRM), what must be done
before deploying it to target servers?
A.
B.
C.
D.

Import it into VCRM.


Assign rights to it.
Populate it.
Trust it to the domain.

Answer: C

QUESTION NO: 107

Certpaper.com installed Rapid Deployment pack on two systems. The customer is able to access the
Deployment Server web console on one machine but not the other. The customer discovers that Microsoft
Internet Information Server (IIS)is not installed on the second machine.After installing IIS , the customer
is still unable to access the Deployment Server web console. What is the most likely cause?
A.
B.
C.
D.

The Default permissions on IIS need to be changed to allow access to the web console.
The web console is installed during installation only if IIS is already present.
Only one Deployment Server can run the web console on the network at a time.
The SQL server database is corrupted and needs to be dropped and than recreated.

Answer: B

QUESTION NO: 108


Which utility could you use to configure logical disks in shared storage and shared storage drives on an
MSA 1000?
A.
B.
C.
D.

Rom Based Setup Utility (RBSU)


Array Configuration Utility (ACU)
Online ROM Configuration for Arrays (ORCA)
HP Systems Insight Manager (HP SIM)

Answer: B

QUESTION NO: 109


An enterprise customer wants to use the SmartStart Scripting Toolkit to deploy Microsoft Windows and
Linux to a large number of servers.Which version of the Scripting Toolkit will meet this need?
A.
B.
C.
D.

DOS
Win32
Linux
Netware

Answer: C

QUESTION NO: 110


What enable some HP UPSs to monitor the power waveform of other UPSs and provides redundancy
between them?
A.
B.
C.
D.

load sharing modules


extended runtime modules
wireless paralleling
unijunction transistor interface

Answer: C

QUESTION NO: 111


When attempting to upgrade a systems firmware with HP Systems Insight Manager, you find the target
system is in a low power state. Which technology must the target systems network adapter support in
order to bring it to a full power state?
A.
B.
C.
D.

Wired for management.(WfM)


Wake On Lan (WOL)
iLO
RILOE

Answer: B

QUESTION NO: 112


Which statement is correct regarding clusters connected to an MSA1000?
A.
B.
C.
D.

You must enable Selective Storage Presentation (SSP) when you have a 2-node cluster.
You must disable Selective Storage presentation (SSP)when you have a 2-node cluster.
You must enable Selective Storage Presentation (SSP) when you have more than 1 cluster set.
You must disable Selective Storage presentation (SSP)when you have more than 1 cluster set.

Answer: C
Explanation:
Reference:
Here in page 7 it is stated that it SSP needs to be enabled when using multiple clusters. So there is an error on
question 111.

http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00264595/c00264595.pdf
More info on MSA1000 and SSP:
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00729544/c00729544.pdf

QUESTION NO: 113


Certpaper.com using Rapid Deployment Pack that there are multiple database entries for some of the
servers on the network.What can the customer do to avoid this problem?
A. Ensure that the primary lookup key in the Deployment Server is set to use the unique MAC address of
each server.
B. Synchronize the Deployment Console name with the operating system name.
C. Install the rapid Deployment pack SIM Integration Module.
D. Change the primary lookup key in the Deployment Server to use the serial number of the server.
Answer: D

QUESTION NO: 114


Certpaper.com wants to deploy HP Bladesystem servers using Rapid Deployment pack Linux Edition
(RDP-LE).Which database must be in place on the deployment server before RDP-LE is installed?
A.
B.
C.
D.

Ingres
PostgreSQL
Open SQL
MSDE

Answer: B
QUESTION NO: 115
Certpaper.com loses a drive on a SA5304 controller. While the RAID set is rebuilding, another drive fails
in the same array. No data has been lost.
Which RAID level are you using?
A. RAID 0
B. RAID 5

C. RAID 5 with an online spare


D. RAID 6 (ADG)
Answer: D

QUESTION NO: 116


What changes can be made to increase performance for a read intensive application server?
A.
B.
C.
D.

Use Rom Based Setup Utility (RBSU) to change the cache to write Back Cache.
Use Array Configuration Utility (ACU)to change the cache to write Back Cache.
Use Online Configuration for Raid Arrays (ORCA)to change the Read/write ratio to 90/10.
Use the Array Configuration Utility (ACU) to change the Read/write ratio to 90/10.

Answer: D

QUESTION NO: 117


Where would you insert the /3GB switch setting to take advantage of 3GB of RAM for your applications
a Windows 2000 Advanced Server?
A.
B.
C.
D.

Windows Registry
System Control panel applet
Boot.ini
Autoexec.nt

Answer: C

QUESTION NO: 118


What is a valid method to configure iLO?
A.
B.
C.
D.

SmartStart
Online Raid Configuration for Arrays (ORCA)
Systems Maintenance Utility
Rom Based Setup Utility (F8)

Answer: D

QUESTION NO: 119


What identifies a Host Bus Adapter on a Fibre Channel fabric?
A.
B.
C.
D.

MAC address
World wide name (WWN)
Node name
Serial Number of the HBA

Answer: B

QUESTION NO: 120


What is a key performance feature of the Opteron processors?
A.
B.
C.
D.

The memory controller is located on the processor.


The memory controller is located in the north Bridge chipset.
The memory controller is located on the South Bridge chipset.
The memory controller is located on the F8 chipset.

Answer: A

QUESTION NO: 121


Which primary lookup key does the installation recommend when installing Rapid Deployment pack
(RDP) Windows Edition version 2.0?
A.
B.
C.
D.

SSID
UID
Serial Number (SMBIOS)
MAC Address

Answer: C

QUESTION NO: 122


Which tool provides the flexibility to configure and build a heterogenous rack consisting of different
servers, storage, and networking components from HP?
A.
B.
C.
D.

Custom Builder
Rack Builder
Rack Assistant
Active Answers

Answer: A

QUESTION NO: 123


Which statement best describes Bus Snooping?
A.
B.
C.
D.

The system reads the requested data and subsequent data from the
hard disk.
It is the process of monitoring the I/O bus to locate needed data from another bus master.
It ensures that the I/O write has been written to disk prior to receiving an I/O acknowledgement.
It prefills two cache lines concurrently.

Answer: B

QUESTION NO: 124


Which RAID level provides for concurrent multiple drive failures while maximizing accessible drive
capacity?
A.
B.
C.
D.

RAID 1 +0
RAID 1
RAID 5
RAID 6 (ADG)

Answer: D

QUESTION NO: 125


Microsoft Cluster Server technology employs what kind of sharing mechanism?
A.
B.
C.
D.

shared nothing
shared memory
shared disk
shared processor

Answer: A

QUESTION NO: 126


In a G4 server, which memory technology offers the best performance?
A.
B.
C.
D.

SDRAM
DDR
DDR2
RDRAM

Answer: C

QUESTION NO:127
When designing a solution that addresses a Mission Critical requirement for an enterprise customer,
what should be considered as the key success factor in the design?
A.
B.
C.
D.

availability of backup services from a local highly available cluster set


redundancy and protection of replicated data set across multiple sites
failover-failback with manual restart capability of a highly available cluster set
frequency of data set backup to tape library during operation hours

Answer: B

QUESTION NO: 128

Which installation file must be run to install the Linux ProLiant Suppoert pack (PSP) on a Linux server
using Smart Start 7 .xx?
A.
B.
C.
D.

install7xx.sh
install7xx.rpm
install7xx.bat
install7xx.bat

Answer: A

QUESTION NO: 129


The customers server is running low on storage space. Which utility can be used to expand a disk array
for this server?
A.
B.
C.
D.

Array Diagnostic Utility (ADU)


Online Raid Configuration for Arrays (ORCA)
ROM Based Setup Utility (RBSU)
Array Configuration Utility (ACU)

Answer: D

QUESTION NO:130
A Systems Engineer is configuring a fully redundant MSA 1000 subsystem for Certpaper.com. Which
component should be added as part of this solution?
A.
B.
C.
D.

a second array controller


a second power supply
an environmental monitoring unit
a Virtual Replicator

Answer: A

QUESTION NO: 131

An enterprise class customer is setting up a new Fiber Channel SAN spanning multiple buildings that are
300m apart. Which Fibre cable type is the best choice based on functionality and cost?
A.
B.
C.
D.

multimode
single mode
GBIC
ultra-pure glass

Answer: A

QUESTION NO: 132


Which feature of the HP ProLiant iLO Advanced Management pack will allow you to load new ProlLiant
Support packs from a SmartStart CD?
A.
B.
C.
D.
E.

Virtual Machine Management


Virtual Media
Advanced patch management
Virtual Console
Directory Services integration

Answer: B

QUESTION NO: 133


Certpaper.com has two HP ProLiant DL580 G2s running as a Windows 2003 Cluster connected to a
MSA1000. Each HP ProLiant DL580G2 has two 36.4Gb hard drives on which the Windows 2003
operating system is installed. The cluster is currently offline. What could be the cause?
A.
B.
C.
D.

Both HP ProLiant DL580 G2s have failed over and failed back again more than 3 times in 5 minutes.
The Internode communication paths (interconnects) is down.
Both hard drives have failed in one of the HP ProLiant DL580 G2s.
A host bus Adapter (HBA) has failed in one of he HP proLiant DL580G2s.

Answer: A

QUESTION NO: 134


Which proLiant Essentials tool should be considered during the last step of the HP troubleshooting
methodology 6-step process?
A.
B.
C.
D.
E.

performance Management pack


Vulnerability and patch Management pack
Insight Diagnostics
Virtual Machine manager
Rapid Deployment pack

Answer: B

QUESTION NO: 135


When trying to install HP SIM on an HP proLiant running Linux, an error message indicates that the
installed version of postgreSQL has the wrong version number. What is the appropriate step to correct
this problem?
A.
B.
C.
D.

Remove the current version of postgreSQL and restart the installation.


Select the ignore option to continue with the installation.
Select the replace option to continue with the installation.
Add the latest version of postgreSQL to the current version and restart the installation

Answer: A

QUESTION NO: 136


In order for HP Systems Insight Manager to execute commands on managed systems by means of
Distributes Task Facility (DTF), what must be configured on the managed system?
A.
B.
C.
D.

private SSH key


public SSH key
SNMP trap with READ capability
SNMP trap with WRITE capability

Answer: B

QUESTION NO: 137


Which SAN solution service offerings does HP provide to enterprise customers? Select THREE.
A.
B.
C.
D.
E.
F.
G.

Heterogeneous SAN integration


Remote Repair
Integration of Applications
Automatic Disk Replacement
Remote Failover
Basic SAN deployment
Automatic SAN switch management

Answer: A, C, F

QUESTION NO: 138


Certpaper.com is redeploying A ML370 G1 server and is trying to install Windows 2000.Which method
should the customer use to get Windows 2000 installed with the latest HP supplied drives and tools?
A. Perform a Smart Start 5.5 assisted installation, than download and Install the latest ProLiant Support
pack (PSP).
B. Perform a Smart Start 7.1 assisted installation, then download and Install the latest ProLiant Support
pack (PSP).
C. Perform a Smart Start 6.2 assisted installation, than download and install the latest ProLiant Support
pack (PSP).
D. Use a Windows 2000 CD to perform the installation.
Answer: A

QUESTION NO: 139


The ProLiant Essentials Vulnerability and patch Management pack integrates with which HP product?
A.
B.
C.
D.

Rapid Deployment pack


Systems Insight Manager
Workload Management pack
Integrated Administrator

Answer: B

QUESTION NO: 140


After replacing a 5302 array controller with a 6402 controller, you receive an error Boot Controller.
(Unknown Device). Which utility should you use to make sure the new array controller is set as the boot
controller?
A.
B.
C.
D.

Array Configuration Utility (ACU)


Array Diagnostic Utility (ADU)
ROM-Based Setup Utility (RBSU)
SmartStart

Answer: C

Vous aimerez peut-être aussi