Preface

Preface
The Honeywell Enraf 854 ATG (Advanced Technology Gauge) is a servo-based level gauge to be
used in inventory measurement systems on bulk storage tanks.
This installation guide is intended for technicians involved in the exchange of the standard FPM
(Viton) O-ring by the special FFKM (Perlast) O-ring for demanding chemical applications of the
Honeywell Enraf Series 854 ATG and is part of the installation kit, part number U0854969.

EC declaration of conformity
Refer to the EC declaration of conformity, shipped with the instrument.

Legal aspects
The mechanical and electrical installation shall only be carried out by trained personnel with
knowledge of the requirements for installation of explosion-proof equipment in hazardous areas.
The information in this installation guide is the copyright property of Enraf B.V., the Netherlands.
Enraf B.V. disclaims any responsibility for personal injury or damage to equipment caused by:
Deviation from any of the prescribed procedures;
Execution of activities that are not prescribed;
Neglect of the general safety precautions for handling tools, use of electricity and
microwave radiation.
The contents, descriptions and specifications in this installation guide are subject to change without
notice. Enraf B.V. accepts no responsibility for any errors that may appear in this installation guide.

Additional information
Do not hesitate to contact Honeywell Enraf or its representative if you require additional
information.

Part no.: 4416240_Rev03

Installation guide dedicated O-ring 854 ATG


Page 3

Table of Contents

Table of Contents
Preface ................................................................................................................................................. 3
Safety .................................................................................................................................................... 5
Safety aspects of 854 ATG ............................................................................................................. 5
Personal safety ............................................................................................................................... 6
Safety conventions.......................................................................................................................... 6
Installation of the dedicated O-ring ...................................................................................................... 7
Contents of O-ring kit ...................................................................................................................... 7
Required tools ................................................................................................................................. 7
Removing the measuring drum ...................................................................................................... 7
Removing the magnet cover........................................................................................................... 8
Replacing the O-ring ....................................................................................................................... 9
Re-installing the magnet cover ....................................................................................................... 9
Re-installing the measuring drum................................................................................................... 9
Re-installing the displacer ............................................................................................................ 10
Closing the drum compartment cover .......................................................................................... 11
Labelling the gauge ...................................................................................................................... 12
Set level gauge operational .......................................................................................................... 12
Appendix ............................................................................................................................................. 13
Related documents ....................................................................................................................... 13
Product compatibility ..................................................................................................................... 14

Installation guide dedicated O-ring 854 ATG


Page 4

Part no.: 4416240_Rev03

Safety

Safety
Safety aspects of 854 ATG
Warning
Do not use the instrument for anything else than its intended purpose.
For medium pressure applications (till 6 bar), the 854 ATG drum compartment housing is of
aluminium.
For high pressure applications (max. 40 bar), the 854 ATG housing is of stainless steel.
The housing of the 854 ATG is explosion-proof:

II 1/2 G Ex d IIB T6 Ga/Gb or II 1/2G Ex de IIB T6 Ga/Gb or


II 1/2 G Ex d [ia Ga] IIB T6 Ga/Gb or II 1/2G Ex de [ia Ga] IIB T6 Ga/Gb; certified by
KEMA, the Netherlands
Ex d [ia Ga] IIB T6 Ga/Gb or Ex de [ia Ga] IIB T6 Ga/Gb; acc. to IECEx, certified by
KEMA, the Netherlands
Class I, Division 1, Groups B, C & D acc. to ANSI/NFPA no. 70, certified by Factory
Mutual Research USA

Environmental conditions for the 854 ATG are:


ambient temperature
operating pressure

:
:

relative humidity
ingress protection

:
:

-40 to + 65 C (-40 to +149 F)


max. 6 bar for medium pressure and chemical version
max. 40 bar for high pressure version
0 - 100 %
IP65 (NEMA 4), suitable for outdoor installation

The drum compartment, which is in contact with the tank atmosphere, is separated from the
electronic compartment. A magnetic coupling transfers the drum movement (hence, displacer
movement) to the electronic compartment.
The 854 ATG covers can optionally be provided with sealing facilities on the blocking devices,
which traces unauthorized opening.

Part no.: 4416240_Rev03

Installation guide dedicated O-ring 854 ATG


Page 5

Safety

Personal safety
The technician must be trained and certified by Honeywell Enraf in how to exchange the O-ring in
the 854 ATG.
When the 854 ATG is installed in a hazardous area, the technician must work in accordance with
the local, national and company regulations for electrical equipment in hazardous areas.

Warning
In hazardous areas it is compulsory to use personal protection and safety gear such as:
hard helmet, fire-resistive overall, safety shoes, safety glasses and working gloves.
Avoid possible generation of static electricity.
Use non-sparking tools and explosion-proof testers when required or advised.
Make sure no dangerous quantities of combustible gas mixtures
are present in the working area.
Never start working before the work permit has been signed by all parties.
Pay attention to the kind of product in the tank. If any danger for health,
wear a gas mask and take all necessary precautions.

Safety conventions
Warnings, Cautions and Notes are used throughout this installation guide to bring special
matters to the immediate attention of the reader.
A Warning concerns danger to the safety of the technician or user;
A Caution draws the attention to an action which may damage the equipment;
A Note points out a statement deserving more emphasis than the general text, but not
requiring a Warning or a Caution.

Installation guide dedicated O-ring 854 ATG


Page 6

Part no.: 4416240_Rev03

Installation O-ring

Installation of the dedicated O-ring


Contents of O-ring kit
The O-ring kit contains of the following material:

O-ring 98.02 x 3.53 mm; Perlast G75 LT (FFKM)


Indication plate: Special O-ring installed
Sealing wire (length: 100 mm)
Seal
Anti seize grease
Protective gloves

Required tools
The following tools are required:

847 PET (Portable Enraf Terminal) or alternatively the service tool Engauge
Tommy bar or strap wrench 14 mm ( 9/16)
Test weight 25 grams (from set of test weights; Honeywell Enraf part number: A1854061)
Rubber band 40 60 mm ( 1 - 2)
Allen keys: 2.5 mm (3/32) and 5 mm (3/16)
A pair of pliers

Removing the measuring drum


Removing the drum from the housing requires the use of the Portable Enraf Terminal (or the
service tool Engauge). Keep the drum, the outer magnet and the outside of the magnet cap
thoroughly clean.
To remove the drum, proceed as follows (refer to figures 1 and 2):

Issue the CA (calibrate) command to raise the displacer


If applicable close the ball valve and release the pressure gently.
Give the UN (unlock) command to lower the displacer from tank top position.
Issue the FR (freeze) command when the displacer comes within reach.
Switch-off the mains.
If the drum compartment cover (6) is locked by a W&M seal, unseal it.
Remove the drum compartment cover (6).
Remove the displacer from the measuring wire. Attach a small weight on the wire to keep it
positioned in the groove. Do not damage the measuring wire.
Pull out the drum (4), remove the small weight and fix the wire to the drum with a rubber
band.
Do not kink the measuring wire and handle the drum carefully.
If the displacer cannot be accessed through an opening, the gauge must be removed from its
mounting position:
Part no.: 4416240_Rev03

Installation guide dedicated O-ring 854 ATG


Page 7

Installation O-ring

Raise the displacer to the maximum height, at least above the ball valve, when present.
Switch-off the mains.
If applicable close the ball valve and release the pressure gently.
Remove the drum compartment cover (6).

Lift the 854 ATG, raising the displacer above the


connecting flange.
Remove the displacer from the measuring wire.
Attach a small weight on the wire to keep it
positioned in the groove. Do not damage the
Figure 1
Measuring drum
measuring wire.
Pull out the drum (4), remove the small weight and fix the wire to the drum with a rubber
band.
Do not kink the measuring wire and handle the drum with care.

No

Description

Drum house

O-ring NBR 70 (145.00x3.00)

O-ring Sil/FEP (134.50x3.00)

Drum with measuring wire

Magnet cover

Drum compartment cover

Main shaft with inner magnet

O-ring NBR 70 (66.27x3.53)

Screw M6 x 16 with spring washer (6x)

10

W&M seal (optional)

11

O-ring FPM (98.02x3.53) (standard)


to be replaced by:
FFKM (98.02x3.53) (dedicated)

Figure 2 Cross section drum compartment

Removing the magnet cover


Remove the 6 screws M6 x 16 (9) including spring washers (use Allen key 5 mm).
Carefully remove the magnet cover (5) by pulling it towards you. If stuck, move the magnet
cover a little left and right while pulling it towards you.
Installation guide dedicated O-ring 854 ATG
Page 8

Part no.: 4416240_Rev03

Installation O-ring

Caution
Move the magnet cap horizontally towards you and make sure
not to damage the inner magnet.

Replacing the O-ring


Remove the standard Viton O-ring (FPM) (11).
Clean the surface of the O-ring area in the back of the drum housing (1).
Insert the dedicated Perlast O-ring (FFKM) (11) from this kit.

Re-installing the magnet cover


Clean the flange of the magnet cover (5) and apply a little anti seize grease. Use the
protective gloves while applying the anti seize grease.
Clean the inner magnet (7), making sure no metal parts are left behind on the inner
magnet.
Place the magnet cover (5); make sure not to touch the inner magnet (7) as to prevent
damage.
Fix the magnet cover (5) with the 6 screws M6 x 16 (9) including spring washers (use Allen
key 5 mm (3/16)).

Re-installing the measuring drum


Make sure the drum magnet (4) and outside of magnet cover (5) are clean (free from
possible contamination such as rust particles).
Remove the rubber band from the drum and attach a small weight to the measuring wire to
keep the measuring wire under tension. Do not damage the measuring wire.
Unwind some measuring wire; just enough to attach the displacer when the drum is in
place.
Feed the small weight and measuring wire through
the neck of the gauge (refer to figure 3).
Insert the measuring drum (4) into its bearings.
Check the axial free-play of the drum as follows:
- Push the drum towards the magnet cap in
such a way that the drum shaft meets the
magnet cap. Release the drum.
- Bring the drum in a slight vibration. The
drum and drum shaft should now move
towards you with an axial movement of
minimum 1 mm and maximum 2.5 mm.

Figure 3 Re-installing drum

Part no.: 4416240_Rev03

Installation guide dedicated O-ring 854 ATG


Page 9

Installation O-ring

Re-installing the displacer


Remove the test weight, insert the displacer via
a mounting hatch and attach it to the wire.
Note:
If there is no mounting hatch available, the
displacer can be installed by temporarily
removing the gauge from the nozzle.
To provide electrical contact between the measuring
wire and displacer, thus permitting the discharge of
static electricity and preventing loss of the displacer,
the displacer must be secured to the measuring wire.
Recommended method with grounding block on
displacer:
Take an extra piece of wire with a length of
15 20 cm (6 8 inch) and fasten one end
Figure 4 Re-installing displacer
to the measuring wire as follows (refer to
(recommended method)
figure 4, red coloured part).
Loop the wire 2 to 3 times around the eyelet.
Twist the wire around the measuring wire directly above the eyelet (about 5 7 times),
so the wires are interlocked.
Take the other end of the measuring wire and loop it thru the hole in the end of the
displacer hook.
Twist the wire 2 or 3 times around the hook and thru the hole in the end of the displacer
hook.
Bend the wire double and feed it into the small hole of the grounding block, next to the
ground symbol.
Secure the end of the wire by fixing the screw. Use Allen key 2.5 mm (3/32).
Cut off the remaining part of the measuring wire.

Note:
If your displacer does not have the grounding block, it is strongly recommended
to replace the displacer by a newer model with grounding block.

Installation guide dedicated O-ring 854 ATG


Page 10

Part no.: 4416240_Rev03

Installation O-ring

Previous method for displacers without grounding block:


Take an extra piece of wire with a length of 15
20 cm (6 8 inch) and fasten one end to the
measuring wire as follows (refer to figure 5, red
coloured part).
Loop the wire 2 to 3 times around the eyelet
Twist the wire around the measuring wire
directly above the eyelet (about 5 7 times),
so the wires are interlocked.
Take the other end of the measuring wire and
loop it thru the hole in the end of the displacer
hook.
Twist the wire 2 or 3 times around the hook and
thru the hole in the end of the displacer hook.
Loosen the nut on the hook just above the
displacer.
Take the end of the measuring wire and twist
the wire several times around the hook just
above the displacer.
Tighten the nut using a pair of pliers.
Twist the end of the measuring wire a few times
(3 4 times) around the wire running to the nut.
Cut off the remaining part of the measuring wire.

Figure 5 Re-installing displacer


(previous method)

Closing the drum compartment cover


In order to ensure that the cover opens easily, the screw thread must be greased.

Caution
Keep screw threads free from dirt.
Grease them lightly with anti seize grease before closing the instrument.
Use the protective gloves while applying the anti seize grease.
When closing, turn the cover counter clock wise until the thread clicks into place,
and then turn clockwise.

Part no.: 4416240_Rev03

Installation guide dedicated O-ring 854 ATG


Page 11

Installation O-ring

Labelling the gauge

Engrave, or stamp the installation date of the


special O-ring (month year will do) on the
black part of the special O-ring indication plate
(refer to figure 6).
Secure the label by means of the sealing wire
and seal to the hoisting eye (refer to figure 7).
Figure 6 Label for special O-ring
Firmly press the seal preferable by sealing pliers,
or otherwise by suitable pliers.

Figure 7 Labelling the gauge

Set level gauge operational


If applicable, open the ball valve.
Switch on the mains.
Give the UN (unlock) command to lower the displacer from its current position and let the
displacer decent to the product surface.
Perform the Balance test (refer to chapter 5.1 of the Instruction manual Series 854 ATG
level gauge). The outcome should be within the limits ( 3 grams).
Perform the level calibration test (refer to chapter 3.4 of the Instruction manual Series 854
ATG level gauge) and, if applicable, seal the gauge according to W&M procedures.
If the gauge is used in a SIL loop, the 854 SIL Checklist should be completed by a qualified
technician to validate the gauge.

Installation guide dedicated O-ring 854 ATG


Page 12

Part no.: 4416240_Rev03

Appendix

Appendix
Related documents
Installation guide 854 Advanced Technology Gauge
Instruction manual Series 854 ATG level gauge
Safety Manual Series 854 ATG/XTG level gauges
854 SIL checklist
Instruction manual 847 PET

Part no.: 4416240_Rev03

Installation guide dedicated O-ring 854 ATG


Page 13

Appendix

Product compatibility
Refer to the following links for product compatibility of the original (FPM) O-ring and special (FFKM)
O-ring:
www.automationdirect.com/static/specs/prosensechemresistance.pdf
prenseTM Chemical Resistance Chart
www.atomikateknik.com/pdf/Elastomer_guide_chemical_compatibility.pdf
A technical guide to Elastomer Compounds and Chemical Compatibility
www.cog.de/o-ringeprodukte/bestaendigkeitsliste.html
C. Otto Gehrckens GmbH & Co. KG Chemical resistance list

Installation guide dedicated O-ring 854 ATG


Page 14

Part no.: 4416240_Rev03

Notes

Part no.: 4416240_Rev03

Installation guide dedicated O-ring 854 ATG


Page 15

Honeywell Enraf
Delftechpark 39
2628 XJ Delft
The Netherlands
Tel.: +31 (0) 15 2701 100
www.honeywellenraf.com

4416240 Revision 03
February 2015
Honeywell International Inc.

Vous aimerez peut-être aussi