Vous êtes sur la page 1sur 106

INDEX

1 Introduction
Preface
General information
Denitions

Page 1
Page 3
Page 4

2 Power & Control Cables to IEC Standard


Power Cable

0.6/1 kV PVC Insulated, Unarmoured Single-Core Cables


0.6/1 kV PVC Insulated, Unarmoured Multi-Core Cables
0.6/1 kV PVC Insulated, Armoured Multi-Core Cables
0.6/1 kV XLPE Insulated, Unarmoured Single-Core Cables
0.6/1 kV XLPE Insulated, Unarmoured Multi-Core Cables
0.6/1 kV XLPE Insulated, Armoured Multi-Core Cables

Control Cable

Page 5
Page 9
Page 13
Page 21
Page 25
Page 29

0.6/1 kV PVC Insulated, Unarmoured Control Cables

Page 37

0.6/1 kV PVC Insulated, Shielded Control Cables

Page 41

0.6/1 kV PVC Insulated, Armoured Control Cables

Page 45

3 Power & Control Cables to BS Standard


Power Cable

600/1000 V PVC Insulated, Steel Wire Armoured Multi-Core Cables


600/1000 V XLPE Insulated, Unarmoured Single-Core Cables

600/1000 V XLPE Insulated, Steel Wire Armoured Multi-Core Cables

Control Cable

600/1000 V PVC Insulated, Steel Wire Armoured Control Cables

4 Cables For Special Applications


Lead Sheathed Cables

Low Smoke Halogen Free Cables


Other Types / Characteristics

5 Technical Data

Page 53
Page 57
Page 61

Page 65

Page 67
Page 67
Page 68

Recommendations

Page 69

Material properties

Page 73

Short circuit current

Page 80

Formulas

Derating factors
Voltage drop

Page 71
Page 74
Page 83

Coding Key

Page 85

Selection of conductor cross-section

Page 86

Conversion table

Page 87

Certicates

Product Range
Contact Details

Page 88

Page 89
Page 91

Low Voltage
Power and Control Cables

Preface
Low Voltage Power, Control and Special Application Cables are used in various indoor and outdoor
applications in power plants, industries, switchgears, and in railways and trafc signaling systems.
Our products conform to various IEC and BS standards. They are tested at leading international laboratories
and are approved by many utility companies, ministries and major industries.
brand is the manifestation of
s constant endeavor for providing a comprehensive range of
construction materials to satisfy its customers with products of the highest quality standard and safety coupled
with prompt services.
Our cables factory is one of the major industrial units in the ultramodern, fully-integrated
Industrial
Complex.

Industries

Industrial Complex located in Riyadh houses


several industrial units for manufacturing medium/low
voltage products, wires and cables, transformers,
wooden reels (for coiling cables) and PVC compounds
(for insulation and jacketing materials).
Apart from the manufacturing units, the Industrial Complex
also houses a commercial zone, a data/communication
center and other facilities.
The Industrial Complex is symbolic of
growth representing its bright future.

s consistent

Group Overview

From its headquarters in Riyadh, Saudi Arabia,


operates a fully-integrated global network of
manufacturing facilities, design & development centers,
and branches in Dubai (UAE), Doha (Qatar), Cairo
(Egypt), Damascus (Syria), Chennai (India) and many
other countries.
Our major businesses and services include: Electrical
Manufacturing, Electrical Construction, Marketing and
Distribution, Building Industry, Real Estate Development,
Information Technology and Communication.

General Information
Selecting a Power Cable
The following factors are important when selecting a suitable cable construction which is required to
transport electrical energy from the power station to the consumer:

Maximum operating voltage


Insulation level
Frequency
Load to be carried
Magnitude and duration of possible load
Voltage drop
Length of line
Mode of installation, either underground or in air
Chemical and physical properties of soil
Max. and min. ambient air temperature and soil temperature
Specication and requirements to be met

Standards
The cables described in this catalogue are all standard types, and their performance has been proved in
operation. Construction and tests are in accordance with the recommendations of IEC or BS publications
where applicable. Power cables in accordance with other standards ( VDE, NEMA, ICEA ) can be
manufactured upon a customers request.

Weights and Dimensions


Weights and dimensions characteristics are approximate and any deviations are due to manufacturing
tolerance.

Jacket Marking
Standard embossed outer jacket marking consisting of:
1.
2.
3.
4.
5.
6.

Name of manufacturer
CABLES
Type designation, size of conductor, rated voltage
ELECTRIC CABLES
Year of manufacture
Continuous length marking every meter
Any special part number, on request

Denitions
Denitions of Dimensional Values
1. Nominal value
Value by which a quantity is designed and which is often used in tables. Usually, in IEC standard, nominal
values give rise to values to be checked by measurements taking into consideration the specied tolerances.

2. Approximate value
Value which is neither guaranteed nor checked; It is used, for example, for the calculation of other dimensional
values.

3. Median value
When several test results have been obtained and sorted in an ascending or descending order, the median
value is the middle value if the number of available values is odd, and the mean of the two middle values if
the number of available values is even.

4. Fictitious value
Value calculated according to the ctitious method described in Annex. A of IEC 60502-1.

Denitions Concerning Tests


1. Routine tests

Tests made by the manufacturer on each manufactured length of cable to check that each length meets the
specied requirements.

2. Sample tests

Tests made by the manufacturer on samples of completed cable or components taken from a completed
cable, at a specied frequency, so as to verify that the nished product meets the specied requirements.

3. Type tests

Tests made before supplying on a general commercial basis, a type of cable covered by this standard, in order
to demonstrate satisfactory performance characteristics to meet the intended application. These tests are of

such a nature that, after they have been made, they need not be repeated, unless changes are made in the cable
materials or design or manufacturing process, which might change the performance characteristics.

4. Electrical tests after installation

Tests made to demonstrate the integrity of the cable and its accessories after installation.

Power Cables

To IEC Standard

Single-Core Cables, with Stranded Circular Copper


Conductors, PVC Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular copper conductor, as per Class 2 of


IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C


at normal operation to IEC 60502-1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type ST1 to IEC 60502-1.

APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is
not exposed to mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit for 5 seconds:

160 C for sizes 300 mm2


140 C for sizes > 300 mm2

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


CU / PVC / PVC

Nominal
cross
sectional
area
mm2
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

0.6 / 1 kV

DIMENSIONS AND
WEIGHTS

ELECTRICAL DATA
Max. Conductor
Resistance
DC at
20 C

/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

AC at
70 C

/ km
5.5100
3.6800
2.1700
1.3700
0.8600
0.6300
0.4600
0.3200
0.2300
0.1900
0.1500
0.1200
0.0920
0.0750
0.0590
0.0480
0.0390
0.0290
0.0250

Current Rating
Laid in ground
Laid in free air

A
42
52
70
90
115
135
160
200
235
270
300
345
400
450
515
580
660
740
820

A
40
50
67
85
110
130
155
190
225
255
285
325
375
420
475
525
590
650
710

A
32
40
52
65
85
105
125
155
185
210
235
270
310
350
390
435
495
555
605

A
37
48
66
80
105
130
160
200
250
285
330
380
480
550
630
720
830
940
1030

A
33
42
58
75
95
125
150
190
240
275
320
370
460
530
615
700
810
920
1010

Approx.
overall
diameter

Approx.
overall
weight

mm

38

7.9

Kg / km
85
115
165
230
345
445
600
805
1085
1350
1655
2030
2675
3280
4350
5355
6685
8600
10500

29
51
65

7.0
8.9
9.9

90

11.6

135

14.6

110
170
210
245
280
320
385
450
520
600
680
775
860

12.7
16.3
18.7
20.4
22.6
24.9
28.3
31.1
35.3
38.8
42.7
47.2

52.0

AES Code

C212PA10100CBK51IMR
C213PA10100CBK51IMR
C314PA10100CBK51IMR
C315PA10100CBK51IMR
C316PA10100CBK51IMR
C317PA10100CBK51IMR
C318PA10100CBK51IMR
C319PA10100CBK51IMR
C345PA10100CBK51IMR
C346PA10100CBK51IMR
C347PA10100CBK51IMR
C348PA10100CBK51IMR
C349PA10100CBK51IMR
C350PA10100CBK51IMR
C351PA10100CBK51IMF
C352PA10100CBK51IMF
C353PA10100CBK51IMF
C354PA10100CBK51IMF
C355PA10100CBK51IMF

Single-Core Cables, with Stranded Circular Aluminum


Conductors, PVC Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular aluminium conductor, as per Class 2 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C


at normal operation to IEC 60502-1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type ST1 to IEC 60502-1.

APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is
not exposed to mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit for 5 seconds:

160 C for sizes 300 mm2


140 C for sizes > 300 mm2

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


AL / PVC / PVC

Nominal
cross
sectional
area
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

0.6 / 1 kV

DIMENSIONS AND
WEIGHTS

ELECTRICAL DATA
Current Rating
Laid in ground
Laid in free air

Max. Conductor
Resistance
DC at
20 C

/ km
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
0.0778
0.0605
0.0469
0.0367
0.0291

AC at
70 C

/ km
2.2900
1.4400
1.0430
0.7700
0.5330
0.3850
0.3050
0.2480
0.1980
0.1510
0.1220
0.0954
0.0751
0.0595
0.0470
0.0370

65
85
105
125
155
185
210
235
265
310
355
410
465
535
600
665

63
83
102
120
145
175
200
225
255
295
335
380
430
490
530
585

50
65
80
95
120
135
165
180
205
240
270
310
355
405
450
495

65
85
105
125
165
205
235
265
310
365
420
500
580
680
765
840

60
80
100
120
155
195
225
255
300
355
405
480
560
660
745
820

45
65
85
105
125
160
185
210
245
290
335
390
460
535
620
690

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

9.9
11.6
12.7
14.6
16.3
18.7
20.4
22.6
24.8
28.3
31.1
35.3
38.8
42.7
47.2
52.0

135
185
250
295
375
500
605
725
900
1150
1420
1750
2220
2750
3450
4230

AES Code

A315PA10100CBK51IMR
A316PA10100CBK51IMR
A317PA10100CBK51IMR
A318PA10100CBK51IMR
A319PA10100CBK51IMR
A345PA10100CBK51IMR
A346PA10100CBK51IMR
A347PA10100CBK51IMR
A348PA10100CBK51IMR
A349PA10100CBK51IMR
A350PA10100CBK51IMR
A351PA10100CBK51IMR
A352PA10100CBK51IMF
A353PA10100CBK51IMF
A354PA10100CBK51IMF
A355PA10100CBK51IMF

Multi-Core Cables, with Stranded Copper


Conductors, PVC Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular (rm) or sector shaped (sm) copper


conductor, as per Class 2 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C


at normal operation to IEC 60502-1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type ST1 to IEC 60502-1.

APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is
not exposed to mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

12.1000
7.4100
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

14.6000
8.8700
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280

1.5
2.5
4
6
10
16
25
35

1.5
2.5
4
6
10
16
25
35

rm
rm
rm
rm
rm
rm
rm
rm

rm
rm
rm
rm
rm
rm
rm
sm

Max. Conductor Resistance

12.1000
7.4100
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

14.6000
8.8700
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

20
28
39
50
66
88
116
143

10.1
10.9
12.9
13.9
15.8
17.9
21.3
23.5

120
145
205
255
390
527
770
965

C208PA10200CBK01IMR

10.6
11.5
13.6
14.7
16.9
19.0
22.7
22.8

145
190
270
340
510
710
1050
1360

C208PA10300CBK04IMR

Laid in
free air

Two Core Cables


24
30
40
50
65
85
110
130

19
25
32
40
55
65
85
105

Three Core Cables


21
27
35
45
60
75
100
120

18
23
30
36
48
60
80
95

18
22
31
39
53
72
94
110

AES Code

C210PA10200CBK01IMR
C212PA10200CBK01IMR
C213PA10200CBK01IMR
C314PA10200CBK01IMR
C315PA10200CBK01IMR
C316PA10200CBK01IMR
C317PA10200CBK01IMR

C210PA10300CBK04IMR
C212PA10300CBK04IMR
C213PA10300CBK04IMR
C314PA10300CBK04IMR
C315PA10300CBK04IMR
C316PA10300CBK04IMR
C417PA10300CBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


CU / PVC / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

Max. Conductor Resistance

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

rm
rm
rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

12.1000
7.4100
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601

14.6000
8.8700
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
0.4640
0.3220
0.2320
0.1850
0.1510
0.1210
0.0840
0.0770

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm

0.5240 / 1.1500
0.3870 / 0.7270
0.2680 / 0.5240
0.1930 / 0.3870
0.1530 / 0.2680
0.1240 / 0.2680
0.0991 / 0.1930
0.0754 / 0.1530

0.6280 / 1.3900
0.4640 / 0.8700
0.3220 / 0.6280
0.2320 / 0.4640
0.1850 / 0.3220
0.1510 / 0.3220
0.1210 / 0.2320
0.0840 / 0.1850

300 sm

150 sm

0.0601 / 0.1240

Current Rating
Laid in
ground
A

Laid in
ducts
A

18
23
30
36
48
60
80
95
115
145
165
195
220
245
290
320

Approx.
overall
weight

mm

Kg / km

18
22
31
39
53
72
94
110
138
171
209
242
275
314
374
440

11.4
12.4
14.8
16.0
18.5
20.9
25.0
25.1
29.3
32.9
37.8
41.2
45.9
50.7
57.0
63.3

180
230
335
425
650
910
1360
1650
2225
3065
4175
5205
6400
7960
10330
12915

C208PA10400CBK08IMR

1470
2115
2725
3690
4675
5580
7025
9060

C435PA10400CBK08IMR

Laid in
free air

Four Core Cables


21
27
35
45
60
75
100
120
145
175
210
240
270
300
345
390

Approx.
overall
diameter

Four Core Cables with Reduced Neutral

0.0770 / 0.1510

120
145
175
210
240
270
300
345

390

95
115
145
165
195
220
245
290

320

110
138
171
209
242
275
314
374

440

24.0
28.1
31.4
36.1
39.5
43.5
48.2
54.2

60.0

11280

AES Code

C210PA10400CBK08IMR
C212PA10400CBK08IMR
C213PA10400CBK08IMR
C314PA10400CBK08IMR
C315PA10400CBK08IMR
C316PA10400CBK08IMR
C417PA10400CBK08IMR
C418PA10400CBK08IMR
C419PA10400CBK08IMR
C445PA10400CBK08IMR
C446PA10400CBK08IMF
C447PA10400CBK08IMF
C448PA10400CBK08IMF
C449PA10400CBK08IMS
C450PA10400CBK08IMS

C436PA10400CBK08IMR
C437PA10400CBK08IMR
C438PA10400CBK08IMR
C439PA10400CBK08IMF
C440PA10400CBK08IMF
C441PA10400CBK08IMF
C442PA10400CBK08IMS
C443PA10400CBK08IMS

Multi-Core Cables, with Stranded Aluminum


Conductors, PVC Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per


Class 2 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to IEC 60502-1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST1 to IEC 60502-1.

APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is
not exposed to mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm2

/ km

/ km

3.0800
1.9100
1.2000
0.8680

3.3000
2.2900
1.4400
1.0430

10
16
25
35

10
16
25
35

11

rm
rm
rm
rm

rm
rm
rm
sm

Max. Conductor Resistance

3.0800
1.9100
1.2000
0.8680

3.3000
2.2900
1.4400
1.0430

Current Rating
Laid in
ground
A

Laid in
ducts
A

39
46
60
83

Three Core Cables


42
53
70
95

34
42
56
75

Approx.
overall
weight

mm

Kg / km

46
62
81
114

15.8
17.9
21.3
23.5

290
370
435
505

A314PA10200CBK01IMR

37
50
66
88

16.9
19.0
22.7
22.8

320
405
570
700

A314PA10300CBK04IMR

Laid in
free air

Two Core Cables


46
60
77
103

Approx.
overall
diameter

AES Code

A315PA10200CBK01IMR
A316PA10200CBK01IMR
A317PA10200CBK01IMR

A315PA10300CBK04IMR
A316PA10300CBK04IMR
A417PA10300CBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


AL / PVC / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000

3.3000
2.2900
1.4400
1.0430
0.7710
0.5330
0.3850
0.3050
0.2490
0.1990
0.1510
0.1230

0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060

1.0430 / 2.2900
0.7710 / 1.4400
0.5330 / 1.0430
0.3850 / 0.7710
0.3050 / 0.5330
0.2490 / 0.5330
0.1990 / 0.3850
0.1510 / 0.3050
0.1230 / 0.2490

10
16
25
35
50
70
95
120
150
185
240
300

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm

rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

34
42
56
75
85
110
130
150
170
195
225
260

Approx.
overall
weight

mm

Kg / km

37
50
66
88
105
132
160
187
215
248
292
347

18.5
20.9
25.0
25.1
29.3
32.9
37.8
41.2
45.9
50.7
57.0
63.3

395
510
715
800
1060
1380
1865
2300
2760
3400
4345
5400

A314PA10400CBK08IMR

725
970
1240
1660
2040
2435
3025
3830
4720

A435PA10400CBK08IMR

Laid in
free air

Four Core Cables


42
53
70
95
115
135
165
185
210
235
275
310

Approx.
overall
diameter

Four Core Cables with Reduced Neutral


95
115
135
165
185
210
235
275
310

75
85
110
130
150
170
195
225
260

88
105
132
160
187
215
248
292
347

24.0
28.1
31.4
36.1
39.5
43.5
48.2
54.2
60.0

AES Code

A315PA10400CBK08IMR
A316PA10400CBK08IMR
A417PA10400CBK08IMR
A418PA10400CBK08IMR
A419PA10400CBK08IMR
A445PA10400CBK08IMR
A446PA10400CBK08IMF
A447PA10400CBK08IMF
A448PA10400CBK08IMF
A449PA10400CBK08IMS
A450PA10400CBK08IMS

A436PA10400CBK08IMR
A437PA10400CBK08IMR
A438PA10400CBK08IMR
A439PA10400CBK08IMF
A440PA10400CBK08IMF
A441PA10400CBK08IMF
A442PA10400CBK08IMS
A443PA10400CBK08IMS

Multi-Core Cables, with Stranded Copper Conductors,


PVC Insulated, Steel Tape Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular (rm) or sector shaped (sm) copper


conductor, as per Class 2 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Double layer of galvanized steel tapes.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST1 to IEC 60502-1.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

13

Max. Conductor Resistance

6
10
16
25
35

rm
rm
rm
rm
rm

3.0800
1.8300
1.1500
0.7270
0.5240

3.6900
2.1900
1.3900
0.8700
0.6280

4
6
10
16
25
35

rm
rm
rm
rm
rm
sm

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

5.5400
3.6900
2.1900
1.3900
0.8700
0.6280

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

50
66
88
116
143

16.9
18.7
20.7
24.1
26.3

460
585
760
1025
1325

C213PA1020GCBK01IMR

16.4
17.5
19.7
21.8
25.5
25.8

440
525
725
950
1340
1560

C212PA1030GCBK04IMR

Laid in
free air

Two Core Cables


50
65
85
110
130

40
55
65
85
105

Three Core Cables


35
45
60
75
100
120

30
36
48
60
80
95

31
39
53
72
94
110

AES Code

C314PA1020GCBK01IMR
C315PA1020GCBK01IMR
C316PA1020GCBK01IMR
C317PA1020GCBK01IMR

C213PA1030GCBK04IMR
C314PA1030GCBK04IMR
C315PA1030GCBK04IMR
C316PA1030GCBK04IMR
C417PA1030GCBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


CU / PVC / STA / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601

5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
0.4640
0.3220
0.2320
0.1850
0.1510
0.1210
0.0840
0.0770

4
6
10
16
25
35
50
70
95
120
150
185
240
300

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm

rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm

Max. Conductor Resistance

0.5240 / 1.1500
0.3870 / 0.7270
0.2680 / 0.5240
0.1930 / 0.3870
0.1530 / 0.2680
0.1240 / 0.2680
0.0991 / 0.1930
0.0754 / 0.1530
0.0601 / 0.1240

Current Rating
Laid in
ground
A

Laid in
ducts
A

30
36
48
60
80
95
115
145
165
195
220
245
290
320

Approx.
overall
weight

mm

Kg / km

31
39
53
72
94
110
138
171
209
242
275
314
374
440

17.6
18.8
21.3
23.7
27.8
27.9
32.7
37.5
42.4
46.2
50.9
56.1
62.6
68.7

520
630
885
1180
1680
1970
2640
3915
5140
6310
7615
9365
12790
14645

C212PA1040GCBK08IMR

1770
2365
3155
4625
5730
6740
8300
10550
12920

C435PA1040GCBK08IMR

Laid in
free air

Four Core Cables


35
45
60
75
100
120
145
175
210
240
270
300
345
390

Approx.
overall
diameter

Four Core Cables with Reduced Neutral

0.6280 / 1.3900
0.4640 / 0.8700
0.3220 / 0.6280
0.2320 / 0.4640
0.1850 / 0.3220
0.1510 / 0.3220
0.1210 / 0.2320
0.0840 / 0.1850
0.0770 / 0.1510

120
145
175
210
240
270
300
345
390

95
115
145
165
195
220
245
290
320

110
138
171
209
242
275
314
374
440

26.8
30.9
34.6
40.7
44.5
48.5
53.2
59.6
65.4

AES Code

C213PA1040GCBK08IMR
C314PA1040GCBK08IMR
C315PA1040GCBK08IMR
C316PA1040GCBK08IMR
C417PA1040GCBK08IMR
C418PA1040GCBK08IMR
C419PA1040GCBK08IMR
C445PA1040GCBK08IMF
C446PA1040GCBK08IMF
C447PA1040GCBK08IMF
C448PA1040GCBK08IMS
C449PA1040GCBK08IMS
C450PA1040GCBK08IMS

C436PA1040GCBK08IMR
C437PA1040GCBK08IMR
C438PA1040GCBK08IMF
C439PA1040GCBK08IMF
C440PA1040GCBK08IMF
C441PA1040GCBK08IMS
C442PA1040GCBK08IMS
C443PA1040GCBK08IMS

Multi-Core Cables, with Stranded Aluminum Conductors,


PVC Insulated, Steel Tape Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per


Class 2 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Double layer of galvanized steel tapes.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST1 to IEC 60502-1.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

3.0800
1.9100
1.2000
0.8680

3.3000
2.2900
1.4400
1.0430

10
16
25
35

10
16
25
35

15

rm
rm
rm
rm

rm
rm
rm
sm

Max. Conductor Resistance

3.0800
1.9100
1.2000
0.8680

3.3000
2.2900
1.4400
1.0430

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

46
62
81
115

16.7
20.7
24.1
26.3

455
540
730
880

A314PA1020GCBK01IMR

19.7
21.8
25.5
25.8

535
625
855
1250

A314PA1030GCBK04IMR

Laid in
free air

Two Core Cables


46
60
77
103

39
46
60
83

Three Core Cables


42
53
70
95

34
42
56
75

37
50
66
88

AES Code

A315PA1020GCBK01IMR
A316PA1020GCBK01IMR
A317PA1020GCBK01IMR

A315PA1030GCBK04IMR
A316PA1030GCBK04IMR
A417PA1030GCBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


AL / PVC / STA / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000

3.3000
2.2900
1.4400
1.0430
0.7710
0.5330
0.3850
0.3050
0.2490
0.1990
0.1510
0.1230

0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060

1.0430 / 2.2900
0.7710 / 1.4400
0.5330 / 1.0430
0.3850 / 0.7710
0.3050 / 0.5330
0.2490 / 0.5330
0.1990 / 0.3850
0.1510 / 0.3050
0.1230 / 0.2490

10
16
25
35
50
70
95
120
150
185
240
300

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm

rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

34
42
56
75
85
110
130
150
170
195
225
260

Approx.
overall
weight

mm

Kg / km

37
50
66
88
105
132
160
187
215
248
292
347

21.3
23.7
27.8
27.9
32.7
37.5
42.4
46.2
50.9
56.1
62.6
68.7

630
775
1035
1115
1475
2225
2830
3360
3975
4815
5925
7125

A314PA1040GCBK08IMR

1030
1330
1675
2585
3100
3590
4300
5325
6365

A435PA1040GCBK08IMR

Laid in
free air

Four Core Cables


42
53
70
95
115
135
165
185
210
235
275
310

Approx.
overall
diameter

Four Core Cables with Reduced Neutral


95
115
135
165
185
210
235
275
310

75
85
110
130
150
170
195
225
260

88
105
132
160
187
215
248
292
347

26.8
30.9
34.6
40.7
44.5
48.5
53.2
59.6
65.4

AES Code

A315PA1040GCBK08IMR
A316PA1040GCBK08IMR
A417PA1040GCBK08IMR
A418PA1040GCBK08IMR
A419PA1040GCBK08IMR
A445PA1040GCBK08IMR
A446PA1040GCBK08IMF
A447PA1040GCBK08IMF
A448PA1040GCBK08IMF
A449PA1040GCBK08IMS
A450PA1040GCBK08IMS

A436PA1040GCBK08IMR
A437PA1040GCBK08IMR
A438PA1040GCBK08IMR
A439PA1040GCBK08IMF
A440PA1040GCBK08IMF
A441PA1040GCBK08IMF
A442PA1040GCBK08IMS
A443PA1040GCBK08IMS

Multi-Core Cables, with Stranded Copper Conductors,


PVC Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular (rm) or sector shaped (sm) copper


conductor, as per Class 2 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of round galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST1 to IEC 60502-1.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

17

Max. Conductor Resistance

4
6
10
16
25
35

rm
rm
rm
rm
rm
rm

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

5.5400
3.6900
2.1900
1.3900
0.8700
0.6280

4
6
10
16
25
35

rm
rm
rm
rm
rm
sm

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

5.5400
3.6900
2.1900
1.3900
0.8700
0.6280

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

39
50
66
88
116
143

17.8
18.8
21.6
22.4
26.9
29.5

645
735
800
1085
1760
2120

C212PA1020WCBK01IMR

18.5
19.6
21.8
23.9
28.6
28.8

730
835
1080
1350
1985
2420

C212PA1030WCBK04IMR

Laid in
free air

Two Core Cables


40
50
65
85
110
130

32
40
55
65
85
105

Three Core Cables


35
45
60
75
100
120

30
36
48
60
80
100

31
39
53
72
94
110

AES Code

C213PA1020WCBK01IMR
C314PA1020WCBK01IMR
C315PA1020WCBK01IMR
C316PA1020WCBK01IMR
C317PA1020WCBK01IMR

C213PA1030WCBK04IMR
C314PA1030WCBK04IMR
C315PA1030WCBK04IMR
C316PA1030WCBK04IMR
C417PA1030WCBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


CU / PVC / SWA / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601

5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
0.4640
0.3220
0.2320
0.1850
0.1510
0.1210
0.0840
0.0770

4
6
10
16
25
35
50
70
95
120
150
185
240
300

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm

rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm

Max. Conductor Resistance

0.5240 / 1.1500
0.3870 / 0.7270
0.2680 / 0.5240
0.1930 / 0.3870
0.1530 / 0.2680
0.1240 / 0.2680
0.0991 / 0.1930
0.0754 / 0.1530
0.0601 / 0.1240

Current Rating
Laid in
ground
A

Laid in
ducts
A

29
37
50
68
89
95
115
145
165
195
220
245
290
320

Approx.
overall
weight

mm

Kg / km

29
37
50
68
89
116
143
176
215
248
281
319
380
446

19.7
20.9
23.4
26.5
30.6
30.9
37.1
40.7
46.6
50.6
55.1
60.5
66.8
72.9

840
965
1275
1780
2380
2690
3870
4900
6665
7990
9445
11425
14205
17870

C212PA1040WCBK08IMR

2460
3550
4480
5475
7385
8505
10260
12755
15330

C435PA1040WCBK08IMR

Laid in
free air

Four Core Cables


37
47
63
79
105
120
145
175
210
240
270
300
345
390

Approx.
overall
diameter

Four Core Cables with Reduced Neutral

0.6280 / 1.3900
0.4640 / 0.8700
0.3220 / 0.6280
0.2320 / 0.4640
0.1850 / 0.3220
0.1510 / 0.3220
0.1210 / 0.2320
0.0840 / 0.1850
0.0770 / 0.1510

120
145
175
210
240
270
300
345
390

95
115
145
165
195
220
245
290
320

116
143
176
215
248
281
319
380
446

29.8
35.5
39.2
42.6
48.9
52.7
57.6
64.0
69.8

AES Code

C213PA1040WCBK08IMR
C314PA1040WCBK08IMR
C315PA1040WCBK08IMR
C316PA1040WCBK08IMR
C417PA1040WCBK08IMR
C418PA1040WCBK08IMR
C419PA1040WCBK08IMR
C445PA1040WCBK08IMF
C446PA1040WCBK08IMF
C447PA1040WCBK08IMF
C448PA1040WCBK08IMS
C449PA1040WCBK08IMS
C450PA1040WCBK08IMS

C436PA1040WCBK08IMR
C437PA1040WCBK08IMR
C438PA1040WCBK08IMF
C439PA1040WCBK08IMF
C440PA1040WCBK08IMF
C441PA1040WCBK08IMS
C442PA1040WCBK08IMS
C443PA1040WCBK08IMS

Multi-Core Cables, with Stranded Aluminum Conductors,


PVC Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per


Class 2 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of round galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST1 to IEC 60502-1.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

3.0800
1.9100
1.2000
0.8680

3.3000
2.2900
1.4400
1.0430

10
16
25
35

10
16
25
35

19

rm
rm
rm
rm

rm
rm
rm
sm

Max. Conductor Resistance

3.0800
1.9100
1.2000
0.8680

3.3000
2.2900
1.4400
1.0430

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

46
62
81
115

21.6
22.4
26.9
29.5

680
825
1450
2250

A314PA1020WCBK01IMR

21.8
23.9
28.6
28.8

915
1525
1875
2330

A314PA1030WCBK04IMR

Laid in
free air

Two Core Cables


46
60
77
103

39
46
60
83

Three Core Cables


42
53
70
95

34
42
56
75

37
50
66
88

AES Code

A315PA1020WCBK01IMR
A316PA1020WCBK01IMR
A317PA1020WCBK01IMR

A315PA1030WCBK04IMR
A316PA1030WCBK04IMR
A417PA1030WCBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


AL / PVC / SWA / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

Max. Conductor Resistance

Current Rating

/ km

Laid in
ground
A

Laid in
ducts
A

Laid in
free air
A

42
53
70
95
115
135
165
185
210
235
275
310

34
42
56
75
85
110
130
150
170
195
225
260

37
50
66
88
105
138
165
193
220
253
297
352

10
16
25
35
50
70
95
120
150
185
240
300

rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000

3.3000
2.2900
1.4400
1.0430
0.7710
0.5330
0.3850
0.3050
0.2490
0.1990
0.1510
0.1230

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm

0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060

1.0430 / 2.2900
0.7710 / 1.4400
0.5330 / 1.0430
0.3850 / 0.7710
0.3050 / 0.5330
0.2490 / 0.5330
0.1990 / 0.3850
0.1510 / 0.3050
0.1230 / 0.2490

Four Core Cables

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

23.4
26.5
30.6
30.9
37.1
40.7
46.6
50.6
55.1
60.5
66.8
72.9

1420
1720
2110
1780
3040
3750
4730
5570
6430
7790
9180
10590

A314PA1040WCBK08IMR

1550
2300
2820
3410
4370
5080
5950
7230
8540

A435PA1040WCBK08IMR

Four Core Cables with Reduced Neutral


95
115
135
165
185
210
235
275
310

75
85
110
130
150
170
195
225
260

94
110
138
165
193
220
253
297
352

29.8
35.5
39.2
42.6
48.9
52.7
57.6
64.0
69.8

AES Code

A315PA1040WCBK08IMR
A316PA1040WCBK08IMR
A417PA1040WCBK08IMR
A418PA1040WCBK08IMR
A419PA1040WCBK08IMR
A445PA1040WCBK08IMR
A446PA1040WCBK08IMF
A447PA1040WCBK08IMF
A448PA1040WCBK08IMF
A449PA1040WCBK08IMS
A450PA1040WCBK08IMS

A436PA1040WCBK08IMR
A437PA1040WCBK08IMR
A438PA1040WCBK08IMR
A439PA1040WCBK08IMF
A440PA1040WCBK08IMF
A441PA1040WCBK08IMF
A442PA1040WCBK08IMS
A443PA1040WCBK08IMS

Single-Core Cables, with Stranded Circular Copper


Conductors, XLPE Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular copper conductor, as per Class 2 of IEC


60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation, rated


90 C at normal operation to IEC 60502-1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST2 to IEC 60502-1.

APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is not
exposed to mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

21

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


CU / XLPE / PVC

Nominal
cross
sectional
area
mm2

4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

0.6 / 1 kV

DIMENSIONS AND
WEIGHTS

ELECTRICAL DATA
Current Rating
Laid in ground
Laid in free air

Max. Conductor
Resistance
DC at
20 C

/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

AC at
90 C

/ km
5.8800
3.9300
2.3300
1.4700
0.9270
0.6690
0.4940
0.3430
0.2480
0.1970
0.1600
0.1290
0.0990
0.0810
0.0638
0.0517
0.0425
0.0292
0.0234

55
68
98
116
150
179
210
263
310
357
394
452
520
588
672
761
872
957
1082

51
65
86
111
142
172
200
247
294
336
373
425
488
546
620
693
777
861
935

40
53
68
87
110
137
163
200
242
273
310
352
404
457
515
572
651
735
798

53
65
84
116
143
179
221
278
347
404
457
530
651
824
893
1008
1155
1313
1449

47
59
79
110
137
173
210
268
336
394
446
520
641
756
872
987
1134
1292
1428

40
53
68
95
121
152
184
236
289
341
389
441
536
620
714
814
956
1092
1208

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

6.8
7.3
8.3
9.3
11.0
12.1
13.8
15.7
17.7
19.6
21.8
23.9
27.1
29.7
33.9
37.4
41.9
46.8
51.5

80
102
150
210
315
410
555
760
1015
1280
1570
1920
2530
3105
4135
5110
6455
8260
10075

AES Code

C212XA10100MBK51IMR
C213XA10100MBK51IMR
C314XA10100MBK51IMR
C315XA10100MBK51IMR
C316XA10100MBK51IMR
C317XA10100MBK51IMR
C318XA10100MBK51IMR
C319XA10100MBK51IMR
C345XA10100MBK51IMR
C346XA10100MBK51IMR
C347XA10100MBK51IMR
C348XA10100MBK51IMR
C349XA10100MBK51IMR
C350XA10100MBK51IMR
C351XA10100MBK51IMF
C352XA10100MBK51IMF
C353XA10100MBK51IMF
C354XA10100MBK51IMF
C355XA10100MBK51IMF

Single-Core Cables, with Stranded Circular Aluminum


Conductors, XLPE Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular aluminum conductor, as per Class 2 of IEC 60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation, rated


90 C at normal operation to IEC 60502-1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST2 to IEC 60502-1.

APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is not
exposed to mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

23

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


AL / XLPE / PVC

Nominal
cross
sectional
area
mm2

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

0.6 / 1 kV

DIMENSIONS AND
WEIGHTS

ELECTRICAL DATA
Current Rating
Laid in ground
Laid in free air

Max. Conductor
Resistance
DC at
20 C

/ km
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
0.0778
0.0605
0.0469
0.0367
0.0291

AC at
90 C

/ km
2.4500
1.5400
1.1130
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310
0.1000
0.0870
0.0620
0.0560
0.0470

89
113
137
163
200
236
278
310
352
410
467
541
609
698
788
872

87
110
131
155
189
226
263
294
336
389
436
504
567
646
704
767

66
84
105
121
152
179
215
236
267
315
357
410
467
536
599
651

89
116
142
173
221
284
326
373
436
515
578
693
809
945
1071
1176

84
110
137
168
215
273
315
362
420
499
567
677
788
924
1050
1155

63
95
121
147
179
215
242
299
336
399
462
541
630
746
851
966

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

9.3
11.0
12.1
13.8
15.7
17.7
19.6
21.8
23.9
27.1
29.7
33.9
37.4
41.9
46.8
51.5

115
165
205
260
340
450
550
670
830
1050
1300
1610
2000
2520
3150
3870

AES Code

A315XA10100MBK51IMR
A316XA10100MBK51IMR
A317XA10100MBK51IMR
A318XA10100MBK51IMR
A319XA10100MBK51IMR
A345XA10100MBK51IMR
A346XA10100MBK51IMR
A347XA10100MBK51IMR
A348XA10100MBK51IMR
A349XA10100MBK51IMR
A350XA10100MBK51IMR
A351XA10100MBK51IMR
A352XA10100MBK51IMF
A353XA10100MBK51IMF
A354XA10100MBK51IMF
A355XA10100MBK51IMF

POWER CABLES / IEC 60502-1


CU / XLPE / PVC

0.6 / 1 kV

Multi-Core Cables, with Stranded Aluminum


Conductors, XLPE Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per


Class 2 of IEC 60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation, rated


90 C at normal operation to IEC 60502-1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST2 to IEC 60502-1.

APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is not
exposed to mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm

/ km

/ km

27

Max. Conductor Resistance

10
16
25
35

rm
rm
rm
rm

3.0800
1.9100
1.2000
0.8680

3.9500
2.4500
1.5400
1.1130

10
16
25
35

rm
rm
rm
sm

3.0800
1.9100
1.2000
0.8680

3.9500
2.4500
1.5400
1.1130

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

55
73
97
120

14.7
16.7
20.1
22.3

335
450
640
780

A314XA10200MBK01IMR

15.6
17.7
21.4
21.5

375
605
835
1050

A314XA10300MBK04IMR

Laid in
free air

Two Core Cables


57
74
97
128

48
58
75
106

Three Core Cables


52
68
90
120

42
52
71
95

48
62
84
105

AES Code

A315XA10200MBK01IMR
A316XA10200MBK01IMR
A317XA10200MBK01IMR

A315XA10300MBK04IMR
A316XA10300MBK04IMR
A417XA10300MBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


AL / XLPE / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm

/ km

/ km

3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000

3.9500
2.4500
1.5400
1.1130
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310

0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060

1.1130 / 2.4500
0.8220 / 1.5400
0.5690 / 1.1130
0.4110 / 0.8220
0.3250 / 0.5690
0.2650 / 0.5690

10
16
25
35
50
70
95
120
150
185
240
300

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm

rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

42
52
71
95
110
140
165
190
215
240
280
315

Approx.
overall
weight

mm

Kg / km

48
62
84
110
136
168
205
236
278
315
378
446

17.0
19.4
23.5
23.6
27.1
31.4
35.1
39.2
43.7
48.7
54.5
60.1

450
700
925
800
950
1260
1650
2060
2520
3140
4020
4930

A314PA10400MBK08IMR

610
925
1255
1630
2030
2515
3095
3900
4795

A435XA10400MBK08IMR

Laid in
free air

Four Core Cables


52
68
90
120
145
175
210
235
265
290
340
390

Approx.
overall
diameter

Four Core Cables with Reduced Neutral

0.2120 / 0.4110
0.1630 / 0.3250
0.1310 / 0.2650

121
145
178
214
243
272
309
359
406

96
116
142
171
195
220
250
292
331

110
136
171
211
246
282
326
388
449

22.5
25.9
29.7
33.6
37.5
41.3
46.2
51.5
56.8

AES Code

A315PA10400MBK08IMR
A316PA10400MBK08IMR
A417PA10400MBK08IMR
A418PA10400MBK08IMR
A419PA10400MBK08IMR

A445XA10400MBK08IMR
A446XA10400MBK08IMF
A447XA10400MBK08IMF
A448XA10400MBK08IMF
A449XA10400MBK08IMS
A450XA10400MBK08IMS

A436XA10400MBK08IMR
A437XA10400MBK08IMR
A438XA10400MBK08IMR
A439XA10400MBK08IMF
A440XA10400MBK08IMF
A441XA10400MBK08IMF
A442XA10400MBK08IMS
A443XA10400MBK08IMS

Multi-Core Cables, with Stranded Copper Conductors,


XLPE Insulated, Steel Tape Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular (rm) or sector shaped (sm) copper


conductor, as per Class 2 of IEC 60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation,


rated 90 C at normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Double layer of galvanized steel tapes.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST2 to IEC 60502-1.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm2

/ km

/ km

3.0800
1.8300
1.1500
0.7270
0.5240

3.9300
2.3300
1.4700
0.9270
0.6690

6
10
16
25
35

6
10
16
25
35

29

rm
rm
rm
rm
rm

rm
rm
rm
rm
sm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

59
78
103
137
164

15.5
17.5
19.5
22.1
23.8

405
530
685
930
1245

C213XA1020GMBK01IMR

16.2
18.4
20.5
24.2
22.8

465
650
870
1235
1370

C213XA1030GMBK04IMR

Laid in
free air

Two Core Cables


62
81
105
138
164

51
68
82
106
132

AES Code

C314XA1020GMBK01IMR
C315XA1020GMBK01IMR
C316XA1020GMBK01IMR
C317XA1020GMBK01IMR

Three Core Cables


3.0800
1.8300
1.1500
0.7270
0.5240

3.9300
2.3300
1.4700
0.9270
0.6690

56
74
96
127
153

44
59
74
100
119

49
67
88
120
143

C314XA1030GMBK04IMR
C315XA1030GMBK04IMR
C316XA1030GMBK04IMR
C417XA1030GMBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


CU / XLPE / STA / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm

/ km

/ km

3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601

3.9300
2.3300
1.4700
0.9270
0.6690
0.4940
0.3430
0.2480
0.1970
0.1600
0.1290
0.0990
0.0810

6
10
16
25
35
50
70
95
120
150
185
240
300

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm

rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm

Max. Conductor Resistance

0.5240 / 1.1500
0.3870 / 0.7270
0.2680 / 0.5240
0.1930 / 0.3870
0.1530 / 0.2680
0.1240 / 0.2680
0.0991 / 0.1930
0.0754 / 0.1530
0.0601 / 0.1240

Current Rating
Laid in
ground
A

Laid in
ducts
A

44
59
74
100
119
145
180
210
245
275
310
365
405

Approx.
overall
weight

mm

Kg / km

49
67
88
120
143
178
215
268
310
352
404
483
562

17.4
19.8
22.2
26.3
26.4
30.1
34.6
39.7
43.8
48.7
53.7
60.0
65.5

555
795
1075
1540
1830
2415
3335
4815
5910
7195
8830
11285
13835

C213XA1040GMBK08IMR

1640
2160
2960
4280
5365
6355
7865
10000
12205

C435XA1040GMBK08IMR

Laid in
free air

Four Core Cables


56
74
96
127
153
185
220
265
305
335
375
435
490

Approx.
overall
diameter

Four Core Cables with Reduced Neutral

0.6690 / 1.4700
0.4940 / 0.9270
0.3430 / 0.6690
0.2480 / 0.4940
0.1970 / 0.3430
0.1600 / 0.3430
0.1290 / 0.2480
0.0990 / 0.1970
0.0810 / 0.1600

153
185
220
265
305
335
375
435
490

119
145
180
210
245
275
310
365
405

143
178
215
268
310
352
404
483
562

25.3
28.7
33.1
38.0
42.1
46.3
51.2
57.1
62.2

AES Code

C314XA1040GMBK08IMR
C315XA1040GMBK08IMR
C316XA1040GMBK08IMR
C417XA1040GMBK08IMR
C418XA1040GMBK08IMR
C419XA1040GMBK08IMR
C445XA1040GMBK08IMF
C446XA1040GMBK08IMF
C447XA1040GMBK08IMF
C448XA1040GMBK08IMS
C449XA1040GMBK08IMS
C450XA1040GMBK08IMS

C436XA1040GMBK08IMR
C437XA1040GMBK08IMR
C438XA1040GMBK08IMF
C439XA1040GMBK08IMF
C440XA1040GMBK08IMF
C441XA1040GMBK08IMS
C442XA1040GMBK08IMS
C443XA1040GMBK08IMS

Multi-Core Cables, with Stranded Aluminum Conductors,


XLPE Insulated, Steel Tape Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular (rm) or sector shaped (sm) aluminum conductor,


as per Class 2 of IEC 60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation,


rated 90 C at normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Double layer of galvanized steel tapes.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST2 to IEC 60502-1.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm2

/ km

/ km

3.0800
1.9100
1.2000
0.8680

3.9500
2.4500
1.5400
1.1130

10
16
25
35

10
16
25
35

31

rm
rm
rm
rm

rm
rm
rm
sm

Max. Conductor Resistance

3.0800
1.9100
1.2000
0.8680

3.9500
2.4500
1.5400
1.1130

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

55
72
96
126

17.5
19.5
22.1
25.1

480
595
810
950

A314XA1020GMBK01IMR

18.4
20.5
24.2
24.5

555
685
925
1110

A314XA1030GMBK04IMR

Laid in
free air

Two Core Cables


56
73
96
129

47
57
74
105

Three Core Cables


52
67
89
120

41
52
70
95

47
62
84
110

AES Code

A315XA1020GMBK01IMR
A316XA1020GMBK01IMR
A317XA1020GMBK01IMR

A315XA1030GMBK04IMR
A316XA1030GMBK04IMR
A417XA1030GMBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


AL / XLPE / STA / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm

/ km

/ km

3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000

3.9500
2.4500
1.5400
1.1130
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310

0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060

1.1130 / 2.4500
0.8220 / 1.5400
0.5690 / 1.1130
0.4110 / 0.8220
0.3250 / 0.5690
0.2650 / 0.5690
0.2120 / 0.4110
0.1630 / 0.3250
0.1310 / 0.2650

10
16
25
35
50
70
95
120
150
185
240
300

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm

rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

41
52
70
95
110
140
165
190
215
240
280
315

Approx.
overall
weight

mm

Kg / km

47
62
84
110
136
168
205
236
278
315
378
446

19.8
22.2
26.3
26.4
30.1
34.6
39.7
43.8
48.7
53.7
60.0
65.5

635
795
1090
970
1490
1750
2540
3020
3670
4380
4430
6510

A314XA1040GMBK08IMR

895
1200
1550
1970
2710
3290
3980
4910
5920

A435XA1040GMBK08IMR

Laid in
free air

Four Core Cables


52
67
89
120
145
175
210
235
265
290
340
390

Approx.
overall
diameter

Four Core Cables with Reduced Neutral


120
145
175
210
235
265
290
340
390

95
110
140
165
190
215
240
280
315

110
136
168
205
236
278
315
378
446

25.3
28.7
33.1
38.0
42.1
46.3
51.2
57.1
62.2

AES Code

A315XA1040GMBK08IMR
A316XA1040GMBK08IMR
A417XA1040GMBK08IMR
A418XA1040GMBK08IMR
A419XA1040GMBK08IMR
A445XA1040GMBK08IMR
A446XA1040GMBK08IMF
A447XA1040GMBK08IMF
A448XA1040GMBK08IMF
A449XA1040GMBK08IMS
A450XA1040GMBK08IMS

A436XA1040GMBK08IMR
A437XA1040GMBK08IMR
A438XA1040GMBK08IMR
A439XA1040GMBK08IMF
A440XA1040GMBK08IMF
A441XA1040GMBK08IMF
A442XA1040GMBK08IMS
A443XA1040GMBK08IMS

Multi-Core Cables, with Stranded Copper Conductors,


XLPE Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular (rm) or sector shaped (sm) copper


conductor, as per Class 2 of IEC 60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation,


rated 90 C at normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of round galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST2 to IEC 60502-1.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm2

/ km

/ km

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

5.8800
3.9300
2.3300
1.4700
0.9270
0.6690

4
6
10
16
25
35

4
6
10
16
25
35

33

rm
rm
rm
rm
rm
rm

rm
rm
rm
rm
rm
sm

Max. Conductor Resistance

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

5.8800
3.9300
2.3300
1.4700
0.9270
0.6690

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

47
61
80
106
140
168

16.6
17.6
19.6
21.6
24.2
27.5

580
660
835
1020
1335
1755

C212XA1020WMBK01IMR

17.2
18.3
20.5
22.6
27.0
27.3

650
755
965
1240
1850
2220

C212XA1030WMBK04IMR

Laid in
free air

Two Core Cables


51
64
83
107
140
168

41
53
70
84
108
135

Three Core Cables


46
58
76
98
130
158

37
46
61
76
103
122

42
51
69
90
120
147

AES Code

C213XA1020WMBK01IMR
C314XA1020WMBK01IMR
C315XA1020WMBK01IMR
C316XA1020WMBK01IMR
C317XA1020WMBK01IMR

C213XA1030WMBK04IMR
C314XA1030WMBK04IMR
C315XA1030WMBK04IMR
C316XA1030WMBK04IMR
C417XA1030WMBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


CU / XLPE / SWA / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm

/ km

/ km

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601

5.8800
3.9300
2.3300
1.4700
0.9270
0.6690
0.4940
0.3430
0.2480
0.1970
0.1600
0.1290
0.0990
0.0810

4
6
10
16
25
35
50
70
95
120
150
185
240
300

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm

rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm

Max. Conductor Resistance

0.5240 / 1.1500
0.3870 / 0.7270
0.2680 / 0.5240
0.1930 / 0.3870
0.1530 / 0.2680
0.1240 / 0.2680
0.0991 / 0.1930
0.0754 / 0.1530
0.0601 / 0.1240

Current Rating
Laid in
ground
A

Laid in
ducts
A

37
46
61
76
103
122
145
180
210
245
275
310
365
405

Approx.
overall
weight

mm

Kg / km

42
51
69
90
122
147
184
220
273
315
375
410
488
562

18.3
19.5
21.9
25.0
29.1
29.4
33.1
39.2
42.9
48.4
53.1
57.9
64.1
69.7

740
860
1155
1630
2220
2520
3200
4645
5870
7555
8985
10760
13480
16215

C212XA1040WMBK08IMR

2250
2860
4240
5290
6475
8055
9735
11780
14435

C435XA1040WMBK08IMR

Laid in
free air

Four Core Cables


46
58
76
98
130
158
185
220
265
305
335
375
435
490

Approx.
overall
diameter

Four Core Cables with Reduced Neutral

0.6690 / 1.4700
0.4940 / 0.9270
0.3430 / 0.6690
0.2480 / 0.4940
0.1970 / 0.3430
0.1600 / 0.3430
0.1290 / 0.2480
0.0990 / 0.1970
0.0810 / 0.1600

158
185
220
265
305
335
375
435
490

122
145
180
210
245
275
310
365
405

147
184
220
273
315
375
410
488
562

27.7
31.3
37.5
41.2
45.3
50.5
55.4
60.3
66.4

AES Code

C213XA1040WMBK08IMR
C314XA1040WMBK08IMR
C315XA1040WMBK08IMR
C316XA1040WMBK08IMR
C417XA1040WMBK08IMR
C418XA1040WMBK08IMR
C419XA1040WMBK08IMR
C445XA1040WMBK08IMF
C446XA1040WMBK08IMF
C447XA1040WMBK08IMF
C448XA1040WMBK08IMS
C449XA1040WMBK08IMS
C450XA1040WMBK08IMS

C436XA1040WMBK08IMR
C437XA1040WMBK08IMR
C438XA1040WMBK08IMF
C439XA1040WMBK08IMF
C440XA1040WMBK08IMF
C441XA1040WMBK08IMS
C442XA1040WMBK08IMS
C443XA1040WMBK08IMS

Multi-Core Cables, with Stranded Aluminum Conductors,


XLPE Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular (rm) or sector shaped (sm) aluminum conductor,


as per Class 2 of IEC 60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation,


rated 90 C at normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of round galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST2 to IEC 60502-1.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm2

/ km

/ km

3.0800
1.9100
1.2000
0.8680

3.9500
2.4500
1.5400
1.1130

10
16
25
35

10
16
25
35

35

rm
rm
rm
rm

rm
rm
rm
sm

Max. Conductor Resistance

3.0800
1.9100
1.2000
0.8680

3.9500
2.4500
1.5400
1.1130

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

60
79
101
131

19.6
21.6
24.2
27.5

635
770
1370
1560

A314XA1020WMBK01IMR

20.5
22.6
27.0
27.3

715
870
1515
1770

A314XA1030WMBK04IMR

Laid in
free air

Two Core Cables


56
73
96
129

47
57
74
105

Three Core Cables


52
67
89
120

41
52
70
95

52
67
89
115

AES Code

A315XA1020WMBK01IMR
A316XA1020WMBK01IMR
A317XA1020WMBK01IMR

A315XA1030WMBK04IMR
A316XA1030WMBK04IMR
A417XA1030WMBK04IMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / IEC 60502-1


AL / XLPE / SWA / PVC

0.6 / 1 kV

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm

/ km

/ km

3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000

3.9500
2.4500
1.5400
1.1130
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310

0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060

1.1130 / 2.4500
0.8220 / 1.5400
0.5690 / 1.1130
0.4110 / 0.8220
0.3250 / 0.5690
0.2650 / 0.5690
0.2120 / 0.4110
0.1630 / 0.3250
0.1310 / 0.2650

10
16
25
35
50
70
95
120
150
185
240
300

35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm

rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

41
52
70
95
110
140
165
190
215
240
280
315

Approx.
overall
weight

mm

Kg / km

52
67
89
115
141
173
210
241
283
320
383
451

21.9
25.0
29.1
29.4
33.1
39.2
42.9
48.4
53.1
57.9
64.1
69.7

785
1335
1630
1700
2330
2760
3340
4320
5080
5990
7220
8440

A314XA1040WMBK08IMR

1500
1870
2600
3090
3690
4700
5550
6560
7820

A435XA1040WMBK08IMR

Laid in
free air

Four Core Cables


52
67
89
120
145
175
210
235
265
290
340
390

Approx.
overall
diameter

Four Core Cables with Reduced Neutral


120
145
175
210
235
265
290
340
390

95
110
140
165
190
215
240
280
315

115
141
173
210
241
283
320
383
451

27.7
31.3
37.5
41.2
45.3
50.5
55.4
60.3
66.4

AES Code

A315XA1040WMBK08IMR
A316XA1040WMBK08IMR
A417XA1040WMBK08IMR
A418XA1040WMBK08IMR
A419XA1040WMBK08IMR
A445XA1040WMBK08IMR
A446XA1040WMBK08IMF
A447XA1040WMBK08IMF
A448XA1040WMBK08IMF
A449XA1040WMBK08IMS
A450XA1040WMBK08IMS

A436XA1040WMBK08IMR
A437XA1040WMBK08IMR
A438XA1040WMBK08IMR
A439XA1040WMBK08IMF
A440XA1040WMBK08IMF
A441XA1040WMBK08IMF
A442XA1040WMBK08IMS
A443XA1040WMBK08IMS

Control Cables

To IEC Standard

Control Cables, with Solid Copper Conductors,


PVC Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed solid copper conductor, as per Class 1 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated


70 C at normal operation to IEC 60502-1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


ST1 to IEC 60502-1.

APPLICATION
For use indoors in cable trenches or ducts; and outdoors - for connecting signaling and control
units in industries, railways, trafc signals, power stations, industrial plants and switchgears if
mechanical protection is not required, or in applications where the cable is not exposed to
mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5

12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000

14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000

37

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

1.5 mm2

18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5

15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0

11.8
12.7
15.7
16.2
17.0
17.8
18.7
21.7
23.8
24.7

200
250
340
385
435
490
560
700
850
1000

Laid in
free air

AES Code

C108PA10500CBK12IMR
C108PA10700CBK21IMR
C108PA11000CBK21IMR
C108PA11200CBK21IMR
C108PA11400CBK21IMR
C108PA11600CBK21IMR
C108PA11900CBK21IMR
C108PA12400CBK21IMF
C108PA13000CBK21IMF
C108PA13700CBK21IMF

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

CONTROL CABLES / IEC 60502-1


CU / PVC / PVC

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5

7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100

8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700

5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area
2

0.6 / 1 kV

Max. Conductor Resistance

4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100

5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100

Current Rating
Laid in
ground
A

24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0

31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0

Laid in
ducts
A

2.5 mm

20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0

4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5

12.9
13.8
17.2
17.7
18.6
19.6
20.6
24.0
25.4
27.4

260
330
450
540
600
670
780
1030
1160
1410

C110PA10500CBK12IMR

24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0

15.3
16.5
20.8
21.5
22.6
23.8
25.1
29.6
31.6
34.1

430
480
670
780
890
1000
1170
1460
1830
2320

C112PA10500CBK12IMR

Laid in
free air

AES Code

C110PA10700CBK21IMR
C110PA11000CBK21IMR
C110PA11200CBK21IMR
C110PA11400CBK21IMR
C110PA11600CBK21IMR
C110PA11900CBK21IMR
C110PA12400CBK21IMF
C110PA13000CBK21IMF
C110PA13700CBK21IMF

C112PA10700CBK21IMR
C112PA11000CBK21IMR
C112PA11200CBK21IMR
C112PA11400CBK21IMR
C112PA11600CBK21IMR
C112PA11900CBK21IMR
C112PA12400CBK21IMF
C112PA13000CBK21IMF
C112PA13700CBK21IMF

Control Cables, with Stranded Copper Conductors,


PVC Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular copper conductor, as per Class 2


of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated


70 C at normal operation to IEC 60502-1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type ST1 to IEC 60502-1.

APPLICATION
For use indoors in cable trenches or ducts; and outdoors - for connecting signaling and control
units in industries, railways, trafc signals, power stations, industrial plants and switchgears if
mechanical protection is not required, or in applications where the cable is not exposed to
mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5

12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000

14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000

39

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

1.5 mm2

18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5

15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0

12.3
13.3
16.5
17.0
17.8
18.7
19.7
22.9
24.2
26.1

215
265
360
410
465
530
600
740
890
1070

Laid in
free air

AES Code

C208PA10500CBK12IMR
C208PA10700CBK21IMR
C208PA11000CBK21IMR
C208PA11200CBK21IMR
C208PA11400CBK21IMR
C208PA11600CBK21IMR
C208PA11900CBK21IMR
C208PA12400CBK21IMF
C208PA13000CBK21IMF
C208PA13700CBK21IMF

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

CONTROL CABLES / IEC 60502-1


CU / PVC / PVC

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5

7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100

8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700

5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area
2

0.6 / 1 kV

Max. Conductor Resistance

4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100

5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100

Current Rating
Laid in
ground
A

Laid in
ducts

2.5 mm

24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0

20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0

4.0 mm2

31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0

25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5

13.4
14.5
18.1
18.7
19.6
20.6
21.7
25.3
26.8
28.9

275
350
480
555
630
710
820
1020
1235
1495

C210PA10500CBK12IMR

24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0

16.1
17.4
22.0
22.7
23.9
25.2
26.6
31.4
33.5
36.2

410
520
720
840
950
1070
1260
1580
1965
2510

C212PA10500CBK12IMR

Laid in
free air

AES Code

C210PA10700CBK21IMR
C210PA11000CBK21IMR
C210PA11200CBK21IMR
C210PA11400CBK21IMR
C210PA11600CBK21IMR
C210PA11900CBK21IMR
C210PA12400CBK21IMF
C210PA13000CBK21IMF
C210PA13700CBK21IMF

C212PA10700CBK21IMR
C212PA11000CBK21IMR
C212PA11200CBK21IMR
C212PA11400CBK21IMR
C212PA11600CBK21IMR
C212PA11900CBK21IMR
C212PA12400CBK21IMF
C212PA13000CBK21IMF
C212PA13700CBK21IMF

Control Cables, with Solid Copper Conductors, PVC


Insulated, Copper Tape Shielded and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed solid copper conductor, as per Class 1 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Shielding

Copper tape applied helically with suitable overlap.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type ST1 to IEC 60502-1.

APPLICATION
For use indoors in cable trenches or ducts; and outdoors - for connecting signaling and control
units in industries, railways, trafc signals, power stations, industrial plants and switchgears if
mechanical protection is not required, or in applications where the cable is not exposed to
mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

41

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

No. X mm2

/ km

/ km

5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5

12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000

14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000

Max. Conductor Resistance

Current Rating
Laid in
ground
A

18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5

Laid in
ducts
A

1.5 mm2
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0

14.2
15.1
18.1
18.6
19.4
20.2
21.1
25.3
27.5
29.4

305
350
465
520
575
635
715
930
1115
1205

Laid in
free air

AES Code

C108PA105N0CBK12IMR
C108PA107N0CBK21IMR
C108PA110N0CBK21IMR
C108PA112N0CBK21IMR
C108PA114N0CBK21IMR
C108PA116N0CBK21IMR
C108PA119N0CBK21IMR
C108PA124N0CBK21IMF
C108PA130N0CBK21IMF
C108PA137N0CBK21IMF

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

CONTROL CABLES / IEC 60502-1


CU / PVC / CT SHIELDED / PVC

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5

7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100

8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700

5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area
2

0.6 / 1 kV

Max. Conductor Resistance

4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100

5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100

Current Rating
Laid in
ground
A

24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0

31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0

Laid in
ducts
A

2.5 mm

20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0

4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5

15.1
16.2
19.6
20.1
21.0
22.0
23.0
26.4
27.8
30.0

380
450
560
650
750
830
970
1260
1380
1670

C110PA105N0CBK12IMR

24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0

18.5
19.9
23.2
23.9
25.0
26.2
27.5
32.0
34.0
36.7

540
670
800
920
1080
1230
1430
1780
2210
2790

C112PA105N0CBK12IMR

Laid in
free air

AES Code

C110PA107N0CBK21IMR
C110PA110N0CBK21IMR
C110PA112N0CBK21IMR
C110PA114N0CBK21IMR
C110PA116N0CBK21IMR
C110PA119N0CBK21IMR
C110PA124N0CBK21IMF
C110PA130N0CBK21IMF
C110PA137N0CBK21IMF

C112PA107N0CBK21IMR
C112PA110N0CBK21IMR
C112PA112N0CBK21IMR
C112PA114N0CBK21IMR
C112PA116N0CBK21IMR
C112PA119N0CBK21IMR
C112PA124N0CBK21IMF
C112PA130N0CBK21IMF
C112PA137N0CBK21IMF

Control Cables, with Stranded Copper Conductors, PVC


Insulated, Copper Tape Shielded and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular copper conductor, as per Class 2


of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated


70 C at normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Shielding

Copper tape applied helically with suitable overlap.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type ST1 to IEC 60502-1.

APPLICATION
For use indoors in cable trenches or ducts; and outdoors - for connecting signaling and control
units in industries, railways, trafc signals, power stations, industrial plants and switchgears if
mechanical protection is not required, or in applications where the cable is not exposed to
mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

43

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

No. X mm2

/ km

/ km

5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5

12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000

14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000

Max. Conductor Resistance

Current Rating
Laid in
ground
A

18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5

Laid in
ducts
A

1.5 mm2
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0

15.7
16.5
18.9
19.4
20.2
21.1
22.1
25.3
27.5
28.5

340
370
495
550
610
670
760
930
1115
1290

Laid in
free air

AES Code

C208PA105N0CBK12IMR
C208PA107N0CBK21IMR
C208PA110N0CBK21IMR
C208PA112N0CBK21IMR
C208PA114N0CBK21IMR
C208PA116N0CBK21IMR
C208PA119N0CBK21IMR
C208PA124N0CBK21IMF
C208PA130N0CBK21IMF
C208PA137N0CBK21IMF

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

CONTROL CABLES / IEC 60502-1


CU / PVC / CT SHIELDED / PVC

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5

7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100

8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700

5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area
2

0.6 / 1 kV

Max. Conductor Resistance

4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100

5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100

Current Rating
Laid in
ground
A

24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0

31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0

Laid in
ducts
A

2.5 mm

20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0

4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5

15.8
16.9
20.5
21.1
22.0
23.0
24.1
27.7
26.8
31.5

390
470
630
710
800
875
1000
1225
1240
1750

C210PA105N0CBK12IMR

24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0

18.5
19.9
24.4
25.2
26.3
27.6
29.0
33.8
35.9
38.8

540
670
850
980
1160
1310
1520
1900
2350
2970

C212PA105N0CBK12IMR

Laid in
free air

AES Code

C210PA107N0CBK21IMR
C210PA110N0CBK21IMR
C210PA112N0CBK21IMR
C210PA114N0CBK21IMR
C210PA116N0CBK21IMR
C210PA119N0CBK21IMR
C210PA124N0CBK21IMF
C210PA130N0CBK21IMF
C210PA137N0CBK21IMF

C212PA107N0CBK21IMR
C212PA110N0CBK21IMR
C212PA112N0CBK21IMR
C212PA114N0CBK21IMR
C212PA116N0CBK21IMR
C212PA119N0CBK21IMR
C212PA124N0CBK21IMF
C212PA130N0CBK21IMF
C212PA137N0CBK21IMF

Control Cables, with Solid Copper Conductors, PVC


Insulated, Steel Tape Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed solid copper conductor, as per Class 1 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Double layer of galvanized steel tape.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type ST1 to IEC 60502-1.

APPLICATION
For outdoor installations, for connecting signaling and control units in industries, railways,
trafc signals, power stations, industrial plants and switchgears if mechanical protection is
required, or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

45

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

No. X mm2

/ km

/ km

5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5

12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000

14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000

Max. Conductor Resistance

Current Rating
Laid in
ground
A

18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5

Laid in
ducts
A

1.5 mm2
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0

15.0
15.5
18.5
19.0
20.6
21.0
21.5
24.5
25.8
27.5

355
410
540
590
670
720
800
970
1170
1315

Laid in
free air

AES Code

C108PA1050GCBK12IMR
C108PA1070GCBK21IMR
C108PA1100GCBK21IMR
C108PA1120GCBK21IMR
C108PA1140GCBK21IMR
C108PA1160GCBK21IMR
C108PA1190GCBK21IMR
C108PA1240GCBK21IMF
C108PA1300GCBK21IMF
C108PA1370GCBK21IMF

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

CONTROL CABLES / IEC 60502-1


CU / PVC / STA / PVC

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5

7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100

8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700

5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area
2

0.6 / 1 kV

Max. Conductor Resistance

4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100

5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100

Current Rating
Laid in
ground
A

24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0

31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0

Laid in
ducts
A

2.5 mm

20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0

4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5

15.5
16.6
20.0
20.5
21.4
22.4
23.4
27.0
28.2
30.5

340
495
650
760
820
920
1030
1260
1520
1830

C110PA1050GCBK12IMR

24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0

18.9
20.3
23.6
24.1
25.4
26.6
28.1
32.6
34.4
37.3

610
710
890
1140
1180
1300
1500
1890
2480
3030

C112PA1050GCBK12IMR

Laid in
free air

AES Code

C110PA1070GCBK21IMR
C110PA1100GCBK21IMR
C110PA1120GCBK21IMR
C110PA1140GCBK21IMR
C110PA1160GCBK21IMR
C110PA1190GCBK21IMR
C110PA1240GCBK21IMF
C110PA1300GCBK21IMF
C110PA1370GCBK21IMF

C112PA1070GCBK21IMR
C112PA1100GCBK21IMR
C112PA1120GCBK21IMR
C112PA1140GCBK21IMR
C112PA1160GCBK21IMR
C112PA1190GCBK21IMR
C112PA1240GCBK21IMF
C112PA1300GCBK21IMF
C112PA1370GCBK21IMF

Control Cables, with Stranded Copper Conductors, PVC


Insulated, Steel Tape Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular copper conductor, as per Class 2


of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Double layer of galvanized steel tape.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type ST1 to IEC 60502-1.

APPLICATION
For outdoor installations, for connecting signaling and control units in industries, railways,
trafc signals, power stations, industrial plants and switchgears if mechanical protection is
required, or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5

12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000

14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000

47

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area

Max. Conductor Resistance

Current Rating
Laid in
ground
A

18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5

Laid in
ducts
A

1.5 mm

15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0

15.3
17.0
19.3
19.8
21.0
21.9
22.5
25.7
27.3
28.9

350
430
570
625
690
800
850
1030
1185
1400

Laid in
free air

AES Code

C208PA1050GCBK12IMR
C208PA1070GCBK21IMR
C208PA1100GCBK21IMR
C208PA1120GCBK21IMR
C208PA1140GCBK21IMR
C208PA1160GCBK21IMR
C208PA1190GCBK21IMR
C208PA1240GCBK21IMF
C208PA1300GCBK21IMF
C208PA1370GCBK21IMF

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

CONTROL CABLES / IEC 60502-1


CU / PVC / STA / PVC

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5

7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100

8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700

5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area
2

0.6 / 1 kV

Max. Conductor Resistance

4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100

5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100

Current Rating
Laid in
ground
A

24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0

31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0

Laid in
ducts
A

2.5 mm

20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0

4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5

16.2
17.3
20.9
21.5
22.4
23.4
24.5
28.1
30.3
31.9

440
530
710
790
880
970
1090
1340
1630
1875

C210PA1050GCBK12IMR

24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0

19.1
20.4
24.9
25.6
26.7
28.0
29.4
34.4
36.5
39.4

660
740
960
1120
1270
1390
1610
2030
2660
3250

C212PA1050GCBK12IMR

Laid in
free air

AES Code

C210PA1070GCBK21IMR
C210PA1100GCBK21IMR
C210PA1120GCBK21IMR
C210PA1140GCBK21IMR
C210PA1160GCBK21IMR
C210PA1190GCBK21IMR
C210PA1240GCBK21IMF
C210PA1300GCBK21IMF
C210PA1370GCBK21IMF

C212PA1070GCBK21IMR
C212PA1100GCBK21IMR
C212PA1120GCBK21IMR
C212PA1140GCBK21IMR
C212PA1160GCBK21IMR
C212PA1190GCBK21IMR
C212PA1240GCBK21IMF
C212PA1300GCBK21IMF
C212PA1370GCBK21IMF

Control Cables, with Solid Copper Conductors, PVC


Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed solid copper conductor, as per Class 1 of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type ST1 to IEC 60502-1.

APPLICATION
For outdoor installations, for connecting signaling and control units in industries, railways,
trafc signals, power stations, industrial plants and switchgears if mechanical protection is
required, or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5

12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000

14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000

49

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area

Max. Conductor Resistance

Current Rating
Laid in
ground
A

18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5

Laid in
ducts
A

1.5 mm

15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0

16.0
17.2
20.2
22.5
23.3
24.2
25.2
28.0
30.1
33.0

470
530
740
1050
1110
1220
1320
1530
1800
2180

Laid in
free air

AES Code

C108PA1050WCBK12IMR
C108PA1070WCBK21IMR
C108PA1100WCBK21IMR
C108PA1120WCBK21IMR
C108PA1140WCBK21IMR
C108PA1160WCBK21IMR
C108PA1190WCBK21IMR
C108PA1240WCBK21IMF
C108PA1300WCBK21IMF
C108PA1370WCBK21IMF

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

CONTROL CABLES / IEC 60502-1


CU / PVC / SWA / PVC

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5

7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100

8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700

5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area
2

0.6 / 1 kV

Max. Conductor Resistance

4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100

5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100

Current Rating
Laid in
ground
A

24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0

31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0

Laid in
ducts
A

2.5 mm

20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0

4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5

17.2
18.4
22.9
24.2
25.1
26.1
27.4
30.5
33.7
36.6

570
640
1125
1240
1350
1470
1620
1970
2380
2790

C110PA1050WCBK12IMR

24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0

20.2
22.7
26.3
28.2
29.2
30.8
32.1
37.5
40.4
43.3

750
1150
1460
1650
1790
1980
2150
3010
3430
4020

C112PA1050WCBK12IMR

Laid in
free air

AES Code

C110PA1070WCBK21IMR
C110PA1100WCBK21IMR
C110PA1120WCBK21IMR
C110PA1140WCBK21IMR
C110PA1160WCBK21IMR
C110PA1190WCBK21IMR
C110PA1240WCBK21IMF
C110PA1300WCBK21IMF
C110PA1370WCBK21IMF

C112PA1070WCBK21IMR
C112PA1100WCBK21IMR
C112PA1120WCBK21IMR
C112PA1140WCBK21IMR
C112PA1160WCBK21IMR
C112PA1190WCBK21IMR
C112PA1240WCBK21IMF
C112PA1300WCBK21IMF
C112PA1370WCBK21IMF

Control Cables, with Stranded Copper Conductors, PVC


Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular copper conductor, as per Class 2


of IEC 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to IEC 60502-1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type ST1 to IEC 60502-1.

APPLICATION
For outdoor installations, for connecting signaling and control units in industries, railways,
trafc signals, power stations, industrial plants and switchgears if mechanical protection is
required, or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

51

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

No. X mm2

/ km

/ km

5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5

12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000

14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000

Max. Conductor Resistance

Current Rating
Laid in
ground
A

18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5

Laid in
ducts
A

1.5 mm2
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0

16.6
18.0
21.0
23.3
24.2
25.0
26.0
28.9
31.0
34.0

500
550
770
1080
1140
1260
1370
1620
1850
2250

Laid in
free air

AES Code

C208PA1050WCBK12IMR
C208PA1070WCBK21IMR
C208PA1100WCBK21IMR
C208PA1120WCBK21IMR
C208PA1140WCBK21IMR
C208PA1160WCBK21IMR
C208PA1190WCBK21IMR
C208PA1240WCBK21IMF
C208PA1300WCBK21IMF
C208PA1370WCBK21IMF

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

CONTROL CABLES / IEC 60502-1


CU / PVC / SWA / PVC

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5

7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100

8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700

5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area
2

0.6 / 1 kV

Max. Conductor Resistance

4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100

5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100

Current Rating
Laid in
ground
A

24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0

31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0

Laid in
ducts
A

2.5 mm

20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0

4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5

17.8
19.2
23.8
25.0
26.0
27.0
28.3
31.4
34.5
37.4

600
660
960
1280
1390
1510
1670
2030
2450
2870

C210PA1050WCBK12IMR

24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0

20.8
23.5
27.2
29.0
30.0
31.6
33.0
38.4
41.3
44.5

780
1190
1510
1700
1850
2040
2260
3070
3560
4120

C212PA1050WCBK12IMR

Laid in
free air

AES Code

C210PA1070WCBK21IMR
C210PA1100WCBK21IMR
C210PA1120WCBK21IMR
C210PA1140WCBK21IMR
C210PA1160WCBK21IMR
C210PA1190WCBK21IMR
C210PA1240WCBK21IMF
C210PA1300WCBK21IMF
C210PA1370WCBK21IMF

C212PA1070WCBK21IMR
C212PA1100WCBK21IMR
C212PA1120WCBK21IMR
C212PA1140WCBK21IMR
C212PA1160WCBK21IMR
C212PA1190WCBK21IMR
C212PA1240WCBK21IMF
C212PA1300WCBK21IMF
C212PA1370WCBK21IMF

Power Cables

To BS Standard

Multi-Core Cables, with Stranded Copper Conductors,


PVC Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular (rm) or sector shaped (sm) copper


conductor, as per Class 2 of BS EN 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to BS 7655-3.1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of round galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


TM1 to BS 7655-4.1.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

53

Max. Conductor Resistance

4
6
10
16
25
35

rm
rm
rm
rm
rm
rm

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

5.5400
3.6900
2.1900
1.3900
0.8700
0.6280

4
6
10
16
25
35

rm
rm
rm
rm
rm
sm

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

5.5400
3.6900
2.1900
1.3900
0.8700
0.6280

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

39
50
66
88
116
143

15.1
16.3
19.2
21.2
25.7
27.9

470
560
815
1035
1595
1910

C212PA1020WCBK01BMR

15.8
17.8
20.6
22.8
27.5
26.9

535
735
910
1160
1785
2000

C212PA1030WCBK04BMR

Laid in
free air

Two Core Cables


40
50
65
85
110
130

32
40
55
65
85
105

Three Core Cables


35
45
60
75
100
120

30
36
48
60
80
100

31
39
53
72
94
110

AES Code

C213PA1020WCBK01BMR
C314PA1020WCBK01BMR
C315PA1020WCBK01BMR
C316PA1020WCBK01BMR
C317PA1020WCBK01BMR

C213PA1030WCBK04BMR
C314PA1030WCBK04BMR
C315PA1030WCBK04BMR
C316PA1030WCBK04BMR
C417PA1030WCBK04BMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / BS 6346


CU / PVC / SWA / PVC

600 / 1000 V

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601

5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
0.4640
0.3220
0.2320
0.1850
0.1510
0.1210
0.0840
0.0770

4
6
10
16
25
35
50
70
95
120
150
185
240
300

rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

29
37
50
68
89
95
115
145
165
195
220
245
290
320

Approx.
overall
weight

mm

Kg / km

29
37
50
68
89
116
143
176
215
248
281
319
380
446

17.8
19.0
22.1
25.8
29.9
30.4
35.3
38.9
42.6
47.6
52.1
57.3
63.6
69.7

720
850
1085
1585
2165
2515
3545
4515
5757

Laid in
free air

Four Core Cables


37
47
63
79
105
120
145
175
210
240
270
300
345
390

Approx.
overall
diameter

7430
8755
10710
13380
16176

AES Code

C212PA1040WCBK08BMR
C213PA1040WCBK08BMR
C314PA1040WCBK08BMR
C315PA1040WCBK08BMR
C316PA1040WCBK08BMR
C417PA1040WCBK08BMR
C418PA1040WCBK08BMR
C419PA1040WCBK08BMR
C445PA1040WCBK08BMF
C446PA1040WCBK08BMF
C447PA1040WCBK08BMF
C448PA1040WCBK08BMS
C449PA1040WCBK08BMS
C450PA1040WCBK08BMS

Multi-Core Cables, with Stranded Aluminum Conductors,


PVC Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per


Class 2 of BS EN 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to BS 7655-3.1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of round galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type


TM1 to BS 7655-4.1.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

Max. Conductor Resistance

16
25
35

rm
rm
rm

1.9100
1.2000
0.8680

2.2900
1.4400
1.0430

16
25
35

rm
rm
sm

1.9100
1.2000
0.8680

2.2900
1.4400
1.0430

Current Rating
Laid in
ground
A

Laid in
ducts
A

46
60
83

Approx.
overall
weight

mm

Kg / km

62
81
115

21.2
25.7
27.9

845
1285
1485

A315PA1020WCBK01BMR

22.8
27.5
26.9

875
1325
1380

A315PA1030WCBK04BMR

Laid in
free air

Two Core Cables


60
77
103

Approx.
overall
diameter

AES Code

A316PA1020WCBK01BMR
A317PA1020WCBK01BMR

Three Core Cables

55

53
70
95

42
56
75

50
66
88

A316PA1030WCBK04BMR
A417PA1030WCBK04BMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / BS 6346


600 / 1000 V

AL / PVC / SWA / PVC

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

mm

/ km

/ km

1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000

2.2900
1.4400
1.0430
0.7710
0.5330
0.3850
0.3050
0.2490
0.1990
0.1510
0.1230

16
25
35
50
70
95
120
150
185
240
300

rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

42
56
75
85
110
130
150
170
195
225
260

Approx.
overall
weight

mm

Kg / km

50
66
88
105
138
165
193
220
253
297
352

25.8
29.9
30.4
35.3
38.9
42.6
47.6
52.1
57.3
63.6
69.7

1205
1550
1695
2405
2915
3490
4530
5255
6170
7450
8815

Laid in
free air

Four Core Cables


53
70
95
115
135
165
185
210
235
275
310

Approx.
overall
diameter

AES Code

A315PA1040WCBK08BMR
A316PA1040WCBK08BMR
A417PA1040WCBK08BMR
A418PA1040WCBK08BMR
A419PA1040WCBK08BMR
A445PA1040WCBK08BMR
A446PA1040WCBK08BMF
A447PA1040WCBK08BMF
A448PA1040WCBK08BMF
A449PA1040WCBK08BMS
A450PA1040WCBK08BMS

Single-Core Cables, with Stranded Circular Copper


Conductors, XLPE Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular copper conductor, as per Class 2 of BS EN


60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation, rated


90 C at normal operation to BS 7655-3.1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type 9


to BS 7655-4.2.

APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is not
exposed to mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

57

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / BS 7889


CU / XLPE / PVC

Nominal
cross
sectional
area
mm2

50
70
95
120
150
185
240
300
400
500
630
800
1000

600 / 1000 V

DIMENSIONS AND
WEIGHTS

ELECTRICAL DATA
Current Rating
Laid in ground
Laid in free air

Max. Conductor
Resistance
DC at
20 C

/ km
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

AC at
90 C

/ km
0.4940
0.3430
0.2480
0.1970
0.1600
0.1290
0.0990
0.0810
0.0638
0.0517
0.0425
0.0292
0.0234

210
263
310
357
394
452
520
588
672
761
872
957
1082

200
247
294
336
373
425
488
546
620
693
777
861
935

163
200
242
273
310
352
404
457
515
572
651
735
798

221
278
347
404
457
530
651
824
893
1008
1155
1313
1449

210
268
336
394
446
520
641
756
872
987
1134
1292
1428

184
236
289
341
389
441
536
620
714
814
956
1092
1208

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

12.9
14.7
16.5
18.0
20.1
22.2
24.9
27.7
30.9
34.9
39.3
43.8
51.5

530
730
980
1225
1490
1870
2420
3020
3855
4985
6290
8090
10075

AES Code

C318XA10100MBK51BMR
C319XA10100MBK51BMR
C345XA10100MBK51BMR
C346XA10100MBK51BMR
C347XA10100MBK51BMR
C348XA10100MBK51BMR
C349XA10100MBK51BMR
C350XA10100MBK51BMR
C351XA10100MBK51BMF
C352XA10100MBK51BMF
C353XA10100MBK51BMF
C354XA10100MBK51BMF
C355XA10100MBK51BMF

Single-Core Cables, with Stranded Circular Aluminum


Conductors, XLPE Insulated and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular aluminum conductor, as per Class 2 of BS EN 60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation, rated


90 C at normal operation to BS 7655-3.1.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type 9


to BS 7655-4.2.

APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is not
exposed to mechanical damage.

TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

59

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / BS 7889


AL / XLPE / PVC

Nominal
cross
sectional
area
mm2

50
70
95
120
150
185
240
300
400
500
630
800
1000

600 / 1000 V

DIMENSIONS AND
WEIGHTS

ELECTRICAL DATA
Current Rating
Laid in ground
Laid in free air

Max. Conductor
Resistance
DC at
20 C

/ km
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
0.0778
0.0605
0.0469
0.0367
0.0291

AC at
90 C

/ km
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310
0.1000
0.0870
0.0620
0.0560
0.0470

163
200
236
278
310
352
410
467
541
609
698
788
872

155
189
226
263
294
336
389
436
504
567
646
704
767

121
152
179
215
236
267
315
357
410
467
536
599
651

173
221
284
326
373
436
515
578
693
809
945
1071
1176

168
215
273
315
362
420
499
567
677
788
924
1050
1155

147
179
215
242
299
336
399
462
541
630
746
851
966

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

12.9
14.7
16.5
18.0
20.1
22.2
24.9
27.7
30.9
34.9
39.3
43.8
51.5

235
310
405
495
605
740
945
1160
1465
1855
2355
2990
3870

AES Code

A318XA10100MBK51BMR
A319XA10100MBK51BMR
A345XA10100MBK51BMR
A346XA10100MBK51BMR
A347XA10100MBK51BMR
A348XA10100MBK51BMR
A349XA10100MBK51BMR
A350XA10100MBK51BMR
A351XA10100MBK51BMR
A352XA10100MBK51BMF
A353XA10100MBK51BMF
A354XA10100MBK51BMF
A355XA10100MBK51BMF

Multi-Core Cables, with Stranded Copper Conductors,


XLPE Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular (rm) or sector shaped (sm) copper


conductor, as per Class 2 of BS EN 60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation,


rated 90 C at normal operation to BS 7655-1.3.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of round galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type 9


to BS 7655-4.2.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm2

/ km

/ km

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

5.8800
3.9300
2.3300
1.4700
0.9270
0.6690

4
6
10
16
25
35

4
6
10
16
25
35

61

rm
rm
rm
rm
rm
rm

rm
rm
rm
rm
rm
sm

Max. Conductor Resistance

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240

5.8800
3.9300
2.3300
1.4700
0.9270
0.6690

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

47
61
80
106
140
168

14.7
15.7
17.1
19.8
23.2
26.5

445
520
640
930
1290
1770

C212XA1020WMBK01BMR

15.3
16.4
19.1
21.5
26.2
25.7

500
595
815
1065
1665
1865

C212XA1030WMBK04BMR

Laid in
free air

Two Core Cables


51
64
83
107
140
168

41
53
70
84
108
135

Three Core Cables


46
58
76
98
130
158

37
46
61
76
103
122

42
51
69
90
120
147

AES Code

C213XA1020WMBK01BMR
C314XA1020WMBK01BMR
C315XA1020WMBK01BMR
C316XA1020WMBK01BMR
C317XA1020WMBK01BMR

C213XA1030WMBK04BMR
C314XA1030WMBK04BMR
C315XA1030WMBK04BMR
C316XA1030WMBK04BMR
C417XA1030WMBK04BMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / BS 5467


CU / XLPE / SWA / PVC

600 / 1000 V

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm

/ km

/ km

4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601

5.8800
3.9300
2.3300
1.4700
0.9270
0.6690
0.4940
0.3430
0.2480
0.1970
0.1600
0.1290
0.0990
0.0810

4
6
10
16
25
35
50
70
95
120
150
185
240
300

rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

37
46
61
76
103
122
145
180
210
245
275
310
365
405

Approx.
overall
weight

mm

Kg / km

42
51
69
90
122
147
184
220
273
315
375
410
488
562

16.4
18.5
20.4
23.1
28.2
28.7
32.4
37.4
40.1
45.4
49.9
54.9
60.9
66.5

575
795
960
1280
1990
2335
2975
4270
5375
6980
8280
10103
12660
15305

Laid in
free air

Four Core Cables


46
58
76
98
130
158
185
220
265
305
335
375
435
490

Approx.
overall
diameter

AES Code

C212XA1040WMBK08BMR
C213XA1040WMBK08BMR
C314XA1040WMBK08BMR
C315XA1040WMBK08BMR
C316XA1040WMBK08BMR
C417XA1040WMBK08BMR
C418XA1040WMBK08BMR
C419XA1040WMBK08BMR
C445XA1040WMBK08BMF
C446XA1040WMBK08BMF
C447XA1040WMBK08BMF
C448XA1040WMBK08BMS
C449XA1040WMBK08BMS
C450XA1040WMBK08BMS

Multi-Core Cables, with Stranded Aluminum Conductors,


XLPE Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Stranded circular (rm) or sector shaped (sm) aluminum conductor,


as per Class 2 of BS EN 60228.

Insulation

An extruded layer of Cross linked polyethylene (XLPE) insulation,


rated 90 C at normal operation to BS 7655-1.3.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of round galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound type 9


to BS 7655-4.2.

APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm2

/ km

/ km

1.9100
1.2000
0.8680

2.4500
1.5400
1.1130

16
25
35

rm
rm
rm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

79
101
131

19.8
23.2
26.5

740
980
1340

A315XA1020WMBK01BMR

21.5
26.2
25.7

780
1205
1245

A315XA1030WMBK04BMR

Laid in
free air

Two Core Cables


73
96
129

57
74
105

AES Code

A316XA1020WMBK01BMR
A317XA1020WMBK01BMR

Three Core Cables


16
25
35

63

rm
rm
sm

1.9100
1.2000
0.8680

2.4500
1.5400
1.1130

67
89
120

52
70
95

67
89
115

A316XA1030WMBK04BMR
A417XA1030WMBK04BMR

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

POWER CABLES / BS 5467


AL / XLPE / SWA / PVC

600 / 1000 V

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA
Nominal
cross
sectional
area

DC at 20 C

AC at 90 C

mm

/ km

/ km

1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000

2.4500
1.5400
1.1130
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310

16
25
35
50
70
95
120
150
185
240
300

rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm

Max. Conductor Resistance

Current Rating
Laid in
ground
A

Laid in
ducts
A

52
70
95
110
140
165
190
215
240
280
315

Approx.
overall
weight

mm

Kg / km

67
89
115
141
173
210
241
283
320
383
451

23.1
28.2
28.7
32.4
37.4
40.1
45.4
49.9
54.9
60.9
66.5

900
1370
1510
1835
2665
3095
4070
4775
5550
6720
7925

Laid in
free air

Four Core Cables


67
89
120
145
175
210
235
265
290
340
390

Approx.
overall
diameter

AES Code

A315XA1040WMBK08BMR
A316XA1040WMBK08BMR
A417XA1040WMBK08BMR
A418XA1040WMBK08BMR
A419XA1040WMBK08BMR
A445XA1040WMBK08BMR
A446XA1040WMBK08BMF
A447XA1040WMBK08BMF
A448XA1040WMBK08BMF
A449XA1040WMBK08BMS
A450XA1040WMBK08BMS

Control Cables

To BS Standard

Control Cables, with Stranded Copper Conductors, PVC


Insulated, Steel Wire Armoured and PVC Sheathed

CONSTRUCTION

Conductor

Plain annealed stranded circular copper conductor, as per Class 2


of BS EN 60228.

Insulation

An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 C at


normal operation to BS 7655-3.1.

Bedding

An extruded layer of Polyvinyl chloride (PVC).

Armouring

Single layer of galvanized steel wires.

Outer sheath :

An extruded layer of Polyvinyl chloride (PVC) sheathing compound


type TM1 to BS 7655-4.1.

APPLICATION
For outdoor installations, for connecting signaling and control units in industries, railways,
trafc signals, power stations, industrial plants and switchgears if mechanical protection is
required, or in applications where mechanical damages are expected to occur.

TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds

65

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area

DC at 20 C

AC at 70 C

No. X mm2

/ km

/ km

7 X 1.5
12 X 1.5
19 X 1.5
27 X 1.5
37 X 1.5

12.1000
12.1000
12.1000
12.1000
12.1000

14.6000
14.6000
14.6000
14.6000
14.6000

Max. Conductor Resistance

Current Rating
Laid in
ground
A

16.0
13.0
10.0
8.0
7.5

Laid in
ducts
A

1.5 mm2
14.0
11.5
9.0
7.5
6.5

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

12.5
10.5
8.0
6.5
6.0

15.6
19.7
22.6
27.1
30.0

490
790
1040
1515
1860

Laid in
free air

AES Code

C208PA1070WCBK21BMR
C208PA1120WCBK21BMR
C208PA1190WCBK21BMR
C208PA1270WCBK21BMF
C208PA1370WCBK21BMF

The above data is approximate and subject to manufacturing tolerance.


We reserve the right to change the above gures as a result of product development and/or changes in standard.

CONTROL CABLES / BS 6346


CU / PVC / SWA / PVC

DC at 20 C

AC at 70 C

No. X mm

/ km

/ km

7 X 2.5
12 X 2.5

7.4100
7.4100

8.8700
8.8700

19 X 2.5
27 X 2.5
37 X 2.5

DIMENSIONS
AND WEIGHTS

ELECTRICAL DATA

Number &
Nominal
cross
sectional
area
2

600 / 1000 V

Max. Conductor Resistance

7.4100
7.4100
7.4100

8.8700
8.8700
8.8700

Current Rating
Laid in
ground
A

22.0
18.0

14.0
11.5
10.0

Laid in
ducts
A

2.5 mm

18.5
15.5
12.0
10.0
9.0

Approx.
overall
diameter

Approx.
overall
weight

mm

Kg / km

16.0
13.5

18.3
22.4

725
1025

Laid in
free air

10.5
8.5
7.5

26.9
31.0
34.4

1575
2020
2495

AES Code

C210PA1070WCBK21BMR
C210PA1120WCBK21BMR
C210PA1190WCBK21BMR
C210PA1270WCBK21BMF
C210PA1370WCBK21BMF

4.0 mm

7 X 4.0
12 X 4.0

19 X 4.0
27 X 4.0
37 X 4.0

4.6100
4.6100

4.6100
4.6100
4.6100

5.5100
5.5100

5.5100
5.5100
5.5100

28.0
23.0

18.0
14.5
13.0

23.0
19.5

15.0
12.0
11.0

21.5
18.0

14.0
11.0
10.0

20.9
27.1

31.1
37.1
41.1

940
1570

2115
3110
3840

C212PA1070WCBK21BMR
C212PA1120WCBK21BMR
C212PA1190WCBK21BMR
C212PA1270WCBK21BMF
C212PA1370WCBK21BMF

Cables For
Special Applications

Cables For Special Applications


Lead Sheathed Cables
Construction
Main constructions are as explained for low voltage power and control cables in accordance with IEC 60502-1
or BS 6346 / BS 5467 standards. Lead sheath is applied over an extruded bedding layer.

Application
For outdoor installations in damp and wet locations in chemical
and petrol plants in which mechanical protection is required or in
applications where mechanical damages are expected to occur.

Main properties
Radially watertight
Corrosion resistant
Where necessary, it is available with the longitudinal
watertight protection
Suitable for use in hostile environment or underground
Especially suitable for submarine installation
Resistant to aggressive chemical substances
Offer good protection against rodents

Low Smoke Halogen Free Cables


Construction
Main constructions are as explained for low voltage power and control cables in accordance with IEC 60502-1 or
BS 6724 standards, except that the cables are specially constructed using low smoke, haloge free materials / compounds.

Application
Low smoke halogen free power cables with enhanced characteristics
in case of re are used for applications where harm to human life
and damage to property must be prevented in the event of re,
e.g. in industrial installations, commercial establishments,
hotels, airports, underground stations, railway stations, hospitals,
banks, schools, etc.

Main properties
Reduced smoke and toxic gases emission in the event of re
Reduced acid gases emission in the event of re
Excellent ame retardant properties

67

Other Types / Characteristics


Various types of constructions can be applied to meet special requirements of the customers, that is:
Copper wires screen for control cables
Non-magnetic armour (Aluminium) for single-core cables
Shielded, armoured and lead sheathed power and control cables
Cross linked polyethylene (XLPE) insulation for control cables
Polyvinyl chloride (PVC) insulation, rated 85 C for power and control cables
Fire resistant cables

Cables can also be designed for specic requirements, that is:


Flexibility
Oil resistance
UV resistance
Termite resistance
Hydro-carbon resistance
Acid and alkaline resistance
Installation in wet locations
Flame retardant to IEC 60332-3 or BS EN 50266-2 standards,
Category A, B, C or D

Other possibilities:
Delivery lengths other than standard lengths
Products as per other national and international norms/standards

Technical Data

Recommendations
Installation of Cables
A. Minimum installation radius
None of the low voltage power or control cables should be bent
during installation to a radius smaller than the following:

All multi-core cables : 12 D


All single-core cables : 15 D
Where D is the overall diameter of the cable.
Wherever possible, larger installation radius should be used,
except that the minimum bending radius where the cables are
placed in position adjacent to joints and terminations may be
reduced to 50% of the above values, provided that the bending
is carefully controlled, e.g. by the use of a former.

B. Minimum temperature during installation


It is recommended that the cables are installed only when both the cable and the ambient temperature are
above 0 C and have been so for the past 24 hours, or where special precautions have been taken to maintain the
cable above this temperature.

C. Prevention of moisture ingress


Care should be exercised during installation to avoid any damage to cable coverings. This is important in wet or
other hostile environments. The protective end cap should not be removed from the ends of the cable until immediately
prior to termination or jointing, especially for cables that do not have an extruded bedding. When the caps
have been removed, the unprotected ends of the cable should not be exposed to moisture.

D. Maximum pulling tension


The maximum pulling tension is dependent on the cable design, the mechanical limitations, the conductor
material, and the method of laying and pulling the cables. The maximum permissible pulling force can be
calculated based on the method of pulling as follows:
D.1 Pulling eye attached to the conductor
With pulling eye attached to copper conductors, the maximum pulling tension should not exceed 0.036 times
circular-mil area of conductor ( Cm). With pulling eye attached to aluminum conductors, the maximum
pulling tension should not exceed 0.027 times circular-mil area of conductor (Cm). Or in other words:

Tm = 0.036
Tm = 0.027

69

X
X

n
n

X
X

Cm (Copper)
Cm (Aluminum)

Where
Tm : Maximum pulling tension in N
n : The number of conductors
Cm : Circular mil area of each conductor
The maximum limitation for this calculation is 22240 N for single conductor (1/C) cables, and 44480 N for multi-core
cables. This limitation is due to unequal distribution of tension forces when pulling multiple conductors.
When the calculated pulling tension is close to (or within 10% of) the maximum pulling tension, the use of a tension
gauge during the pulling is recommended.
D.2 Cable grip over lead sheath
With cable grip over lead sheath, with commercial lead, the maximum pulling tension on the lead sheath should not
exceed 10.33 N/mm2.
D.3 Cable grip over non-leaded cable
With cable grip over non-leaded cable, the maximum pulling tension should not exceed 4400 N.

E. Sidewall pressure
One of the limitations to be considered for the installation of electrical cables is sidewall pressure. The sidewall
pressure is the force exerted on the insulation and sheath of the cable at a bend point when the cable is under
tension, and is normally the limiting factor in an installation where cable bends are involved. The sidewall
pressure in general is expressed as the tension out of a bend expressed in newtons divided by the inside radius of the
bend expressed in meters.
P=

To
r

Where
P : Sidewall pressure in N/m
To : Tension leaving the bend in N
r : Inside radius of conduit in m
The normal maximum sidewall pressure per meter of radius is as given below. However, in order to minimize cable
damage due to excessive sidewall pressure, the installer should check the proper recommendations for each
type of cables to be installed.

Cable type

Maximum sidewall pressure ( N/m )

Non-shielded multi-core cables

7300

Armoured cables

4400

Single core cables

7300

Formulas

71

Material Properties
Metals Used For Cables
Table 1
ELECTRICAL PROPERTIES
Metal

Relative Conductivity
Copper 100

Electrical Resistivity at
20 C .m ( 10-8 )

Temperature Coefcient
of Resistance per C

100
97
95 97
61
8

1.7241
1.7770
1.741 1.814
2.8264
21.40

0.00393
0.00393
0.00393
0.00403
0.00400

Copper (Annealed)
Copper (Hard drawn)
Tinned Copper
Aluminum
Lead

PHYSICAL PROPERTIES
Property

Unit

Copper

Kg/m3
C x 10-6
C
W/Cm.C

Density at 20 C
Coeff. of thermal expansion
Melting point
Thermal conductivity

Aluminum

8890.0
17.0
1083.0
3.8

2703.0
23.0
659.0
2.4

Lead
11340.0
29.0
327.0
0.34

Insulation Materials Used For Cables


Table 2
Properties

PVC

Nominal
Emergency
Short Circuit

90
130
250

Mechanical
Strength

Min. Tensile Strength (N/mm2)


Min. Elongation %

12.5
200

12.5
150

4.2
200

Good
2.5
0.93
Good

Poor
8.0
1.5
Poor

10

10
10

Excellent
3.0
1.4
Poor

Easy
Good

Easy
Good

Easy
Poor

* For sizes > 300 mm2


** For sizes 300 mm2

.cm

12

70
95
140 * or 160 **

EPR

Rated Temp.

Heat deformation at 150 C


Relative permittivity
Specic gravity g/cm3
Solvent resistance
Volume Resistivity at max. conductor
temperature in normal operation
Splicing & termination
Environmental stress cracking

73

XLPE

90
130
250

12
10

Derating Factors
Table 3

Ground temperature derating factors


Max. Conductor

Ambient ground temperature C

temperature
C

25

30

35

40

45

50

55

70 C

1.13

1.07

1.00

0.93

0.85

0.76

0.65

90 C

1.09

1.04

1.00

0.95

0.90

0.85

0.80

Table 4

Air temperature derating factors


Max. Conductor

Ambient air temperature C

temperature
C

25

30

35

40

45

50

55

70 C

1.22

1.15

1.08

1.00

0.95

0.82

0.71

1.14

1.10

1.05

1.00

0.95

0.89

0.84

90 C

Table 5

Burial depth derating factors


Depth of laying
mt.
0.50

Cables cross section


Up to 70 mm2
1.00

95 up to 240 mm2
1.00

300 mm 2 & above


1.00

0.60

0.99

0.98

0.97

0.80

0.97

0.96

0.94

1.00

0.95

0.93

0.92

1.25

0.94

0.92

0.89

1.50

0.93

0.90

0.87

1.75

0.92

0.89

0.86

2.00

0.91

0.88

0.85

Derating Factors
Table 6

Soil thermal resistivity derating factors


Soil thermal resistivity C.m / Watt
Rating factor

0.8

0.9

1.0

1.2

1.5

2.0

2.5

1.17

1.12

1.07

1.00

0.91

0.80

0.73

Table 7

PVC rated temperature derating factors


PVC rated temperature C
Rating factor

70

85

95

105

1.000

1.195

1.309

1.414

Table 8

Trefoil or at formation derating factors for three


single core cables laid direct in ground
Spacing

Number

Spacing

Spacing

Spacing

of
Trefoil formation

circuits

75

Touching

Flat formation
Spacing = 0.15 Mt.

Spacing = 0.30 Mt.

Trefoil

Flat

Trefoil

Flat

Trefoil

Flat

0.77

0.80

0.82

0.85

0.88

0.91

0.66

0.69

0.73

0.76

0.80

0.83

0.60

0.63

0.68

0.71

0.74

0.77

0.56

0.59

0.64

0.67

0.72

0.75

0.53

0.57

0.61

0.64

0.70

0.73

Table 9

Flat formation derating factors for three single


core cables laid in free air
Laid on the ground
Clearance = cable diameter ( d )
Clearance from the wall > 2 cm
Rating factor

Number of circuits
1

0.92

0.89

0.88

Laid on cables troughs


Clearance = cable diameter ( d )
Clearance from the wall > 2 cm

( circulation of air is restricted )


Number of circuits

0.92

0.89

0.88

0.87

0.84

0.83

Number of troughs

0.84

0.82

0.81

0.82

0.80

0.79

Laid on cables racks


Clearance = cable diameter ( d )
Clearance from the wall > 2 cm
Number of racks

Number of circuits
1

1.00

0.97

0.96

0.97

0.94

0.93

0.96

0.93

0.92

0.94

0.91

0.90

Arranged near the wall


Number of circuits

Clearance = cable diameter ( d )


Clearance from the wall > 2 cm

Rating factor

0.94

0.91

0.89

Arranged on the wall


Clearance = cable diameter ( d )
Rating factor

Number of circuits
1

0.89

0.86

0.84

Derating Factors
Table 10

Trefoil touching formation derating factors for three single


core cables laid in free air
Laid on the ground
Clearance = 2 cable diameter ( 2d )
Clearance from the wall > 2 cm
Rating factor

Number of circuits
1

0.95

0.90

0.88

Laid on cables troughs


Clearance = 2 cable diameter ( 2d )
Clearance from the wall > 2 cm

( circulation of air is restricted )


Number of circuits

Number of troughs

0.95

0.90

0.88

0.90

0.85

0.83

0.88

0.83

0.81

0.86

0.81

0.79

Laid on cables racks


Clearance = 2 cable diameter ( 2d )
Clearance from the wall > 2 cm
Number of racks

Number of circuits
1

1.00

0.98

0.96

1.00

0.95

0.93

1.00

0.94

0.92

1.00

0.93

0.90

Arrangement for zero reduction


Clearance = 4 cable diameter ( 4d )
Clearance from the wall > 2 cm
Rating factor

77

Number of circuits
1

1.00

1.00

1.00

Table 11

Horizontal or vertical formation derating factors for


multi-core cables laid in free air
Laid on the ground
Clearance = cable diameter ( d )
Clearance from the wall > 2 cm
Rating factor

Number of circuits
1

0.95

0.90

0.88

0.85

0.84

Laid on cables troughs

( circulation of air is restricted )

Clearance = cable diameter ( d )


Clearance from the wall > 2 cm

Number of circuits
1

0.95

0.90

0.88

0.85

0.84

Number of troughs
2

0.90

0.85

0.83

0.81

0.80

0.88

0.83

0.81

0.79

0.78

0.86

0.81

0.79

0.77

0.76

Laid on cables racks


Clearance = cable diameter ( d )
Clearance from the wall > 2 cm

Number of circuits
1

Number of racks

1.00

0.98

0.96

0.93

0.92

1.00

0.95

0.93

0.90

0.89

1.00

0.94

0.92

0.89

0.88

1.00

0.93

0.90

0.87

0.86

Arranged near the wall


Number of circuits

Clearance = cable diameter ( d )


Clearance from the wall > 2 cm

Rating factor

1.00

0.93

0.90

0.87

0.86

Arrangement for zero reduction


Number of circuits

Clearance = 2 cable diameter ( 2d )


Clearance from the wall > 2 cm

Rating factor

1.00

1.00

1.00

1.00

1.00

Derating Factors
Table 12

Derating factors for multi-core cables touching


and in contact with the wall in air
Laid on the ground
Number of circuits

Cables are touched together and in


contact with the wall

Rating factor

0.90

0.84

0.80

0.75

0.73

Laid on cables troughs ( circulation of air is restricted )


Cables are touched together and in
contact with the wall

Number of circuits
1

0.95

0.84

0.80

0.75

0.73

0.95

0.80

0.76

0.71

0.69

0.95

0.78

0.74

0.70

0.68

0.95

0.76

0.72

0.68

0.66

Number of troughs

Laid on cables racks


Cables are touched together and in
contact with the wall

Number of circuits
1

0.95

0.84

0.80

0.75

0.73

0.95

0.80

0.76

0.71

0.69

0.95

0.78

0.74

0.70

0.68

0.95

0.76

0.72

0.68

0.66

Number of racks

Arranged on the wall

79

Number of circuits

Cables are touched together and in


contact with the wall

Rating factor

0.95

0.78

0.73

0.68

0.66

Short Circuit Current


Table 13

Max. short circuit temperature for cable components


Material

Cable component

Insulation

PVC Insulation

Sheathing

Max. short circuit temp. C


140 For C.S.A > 300 mm

2
2

160 For C.S.A > 300 mm

XLPE Insulation

250

PVC Sheath

200

LDPE Sheath

150

HDPE Sheath

180

Lead Sheath

170

Lead Alloy Sheath

200

Table 14

kA short circuit current - copper conductor - PVC insulated


C.S.A
2

mm

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Short circuit duration sec.


0.1

0.55
0.91
1.45
2.18
3.6
5.8
9.1
12.7
18.2
25.5
34.5
43.6
54.5
67.3
87.3
109.1
130.0
162.5
204.8
260.1
325.1

0.2

0.39
0.64
1.03
1.54
2.6
4.1
6.4
9.0
12.9
18.0
24.4
30.9
38.6
47.6
61.7
77.1
91.9
114.9
144.8
183.9
229.9

0.3

0.31
0.52
0.84
1.26
2.1
3.4
5.2
7.3
10.5
14.7
19.9
25.2
31.5
38.8
50.4
63.0
75.1
93.8
118.2
150.1
187.7

0.4

0.27
0.45
0.73
1.09
1.8
2.9
4.5
6.4
9.1
12.7
17.3
21.8
27.3
33.6
43.6
54.5
65.0
81.3
102.4
130.0
162.5

0.5

0.24
0.41
0.65
0.98
1.6
2.6
4.1
5.7
8.1
11.4
15.5
19.5
24.4
30.1
39.0
48.8
58.2
72.7
91.6
116.3
145.4

1.0

0.17
0.29
0.46
0.69
1.2
1.8
2.9
4.0
5.8
8.1
10.9
13.8
17.3
21.3
27.6
34.5
41.1
51.4
64.8
82.2
102.8

2.0

0.12
0.20
0.33
0.49
0.8
1.3
2.0
2.8
4.1
5.7
7.7
9.8
12.2
15.0
19.5
24.4
29.1
36.3
45.8
58.2
72.7

3.0

0.10
0.17
0.27
0.40
0.7
1.1
1.7
2.3
3.3
4.6
6.3
8.0
10.0
12.3
15.9
19.9
23.7
29.7
37.4
47.5
59.4

4.0

0.09
0.14
0.23
0.35
0.6
0.9
1.4
2.0
2.9
4.0
5.5
6.9
8.6
10.6
13.8
17.3
20.6
25.7
32.4
41.1
51.4

5.0

0.08
0.13
0.21
0.31
0.5
0.8
1.3
1.8
2.6
3.6
4.9
6.2
7.7
9.5
12.3
15.4
18.4
23.0
29.0
36.8
46.0

Short Circuit Current


Table 15

kA short circuit current - aluminum conductor - PVC insulated


C.S.A
mm

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Short circuit duration sec.


0.1

3.8
6.0
8.4
12.0
16.8
22.8
28.8
36.0
44.5
57.7
72.1
86.0
107.5
135.5
172.0
215.0

0.2

2.7
4.2
5.9
8.5
11.9
16.1
20.4
25.5
31.4
40.8
51.0
60.8
76.0
95.8
121.6
152.1

0.3

2.2
3.5
4.9
6.9
9.7
13.2
16.7
20.8
25.7
33.3
41.6
49.7
62.1
78.2
99.3
124.2

0.4

1.9
3.0
4.2
6.0
8.4
11.4
14.4
18.0
22.2
28.8
36.0
43.0
53.8
67.7
86.0
107.5

0.5

1.7
2.7
3.8
5.4
7.5
10.2
12.9
16.1
19.9
25.8
32.2
38.5
48.1
60.6
76.9
96.2

1.0

1.2
1.9
2.7
3.8
5.3
7.2
9.1
11.4
14.1
18.2
22.8
27.2
34.0
42.8
54.4
68.0

2.0

0.9
1.3
1.9
2.7
3.8
5.1
6.4
8.1
9.9
12.9
16.1
19.2
24.0
30.3
38.5
48.1

3.0

0.7
1.1
1.5
2.2
3.1
4.2
5.3
6.6
8.1
10.5
13.2
15.7
19.6
24.7
31.4
39.3

4.0

0.6
1.0
1.3
1.9
2.7
3.6
4.6
5.7
7.0
9.1
11.4
13.6
17.0
21.4
27.2
34.0

5.0

0.5
0.8
1.2
1.7
2.4
3.2
4.1
5.1
6.3
8.2
10.2
12.2
15.2
19.2
24.3
30.4

Table 16

kA short circuit current - aluminum conductor - XLPE insulated


C.S.A
mm

16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

81

Short circuit duration sec.


0.1

4.7
7.4
10.4
14.8
20.7
28.1
35.6
44.4
54.8
71.1
88.9
118.5
148.2
186.7
237.0
296.3

0.2

3.4
5.2
7.3
10.5
14.7
19.9
25.1
31.4
38.8
50.3
62.9
83.8
104.8
132.0
167.6
209.5

0.3

2.7
4.3
6.0
8.6
12.0
16.3
20.5
25.7
31.6
41.1
51.3
68.4
85.5
107.8
136.9
171.1

0.4

2.4
3.7
5.2
7.4
10.4
14.1
17.8
22.2
27.4
35.6
44.4
59.3
74.1
93.3
118.5
148.2

0.5

2.1
3.3
4.6
6.6
9.3
12.6
15.9
19.9
24.5
31.8
39.8
53.0
66.3
83.5
106.0
132.5

1.0

1.5
2.3
3.3
4.7
6.6
8.9
11.2
14.1
17.3
22.5
28.1
37.5
46.9
59.0
75.0
93.7

2.0

1.1
1.7
2.3
3.3
4.6
6.3
8.0
9.9
12.3
15.9
19.9
26.5
33.1
41.7
53.0
66.3

3.0

0.9
1.4
1.9
2.7
3.8
5.1
6.5
8.1
10.0
13.0
16.2
21.6
27.0
34.1
43.3
54.1

4.0

0.75
1.2
1.6
2.3
3.3
4.5
5.6
7.0
8.7
11.2
14.1
18.7
23.4
29.5
37.5
46.9

5.0

0.67
1.0
1.5
2.1
2.9
4.0
5.0
6.3
7.8
10.1
12.6
16.8
21.0
26.4
33.5
41.9

Table 17

kA short circuit current - copper conductor - XLPE insulated


C.S.A
mm

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Short circuit duration sec.


0.1

0.7
1.1
1.8
2.7
4.5
7.2
11.3
15.8
22.6
31.7
43.0
54.3
67.8
83.7
108.5
135.7
180.9
226.1
284.9
361.8
452.2

0.2

0.5
0.8
1.3
1.9
3.2
5.1
8.0
11.2
16.0
22.4
30.4
38.4
48.0
59.2
76.7
95.9
127.9
159.9
201.4
255.8
319.8

0.3

0.4
0.7
1.0
1.6
2.6
4.2
6.5
9.1
13.1
18.3
24.8
31.3
39.2
48.3
62.7
78.3
104.4
130.5
164.5
208.9
261.1

0.4

0.3
0.6
0.9
1.4
2.3
3.6
5.7
7.9
11.3
15.8
21.5
27.1
33.9
41.8
54.3
67.8
90.4
113.1
142.4
180.9
226.1

0.5

0.3
0.5
0.8
1.2
2.0
3.2
5.1
7.1
10.1
14.2
19.2
24.3
30.3
37.4
48.5
60.7
80.9
101.1
127.4
161.8
202.2

1.0

0.21
0.36
0.57
0.86
1.4
2.3
3.6
5.0
7.2
10.0
13.6
17.2
21.5
26.5
34.3
42.9
57.2
71.5
90.1
114.4
143.0

2.0

0.15
0.25
0.40
0.61
1.0
1.6
2.5
3.5
5.1
7.1
9.6
12.1
15.2
18.7
24.3
30.3
40.4
50.6
63.7
80.9
101.1

3.0

0.12
0.21
0.33
0.50
0.8
1.3
2.1
2.9
4.1
5.8
7.8
9.9
12.4
15.3
19.8
24.8
33.0
41.3
52.0
66.0
82.6

4.0

0.11
0.18
0.29
0.43
0.7
1.1
1.8
2.5
3.6
5.0
6.8
8.6
10.7
13.2
17.2
21.5
28.6
35.8
45.0
57.2
71.5

5.0

0.10
0.16
0.26
0.38
0.6
1.0
1.6
2.2
3.2
4.5
6.1
7.7
9.6
11.8
15.3
19.2
25.6
32.0
40.3
51.2
64.0

Voltage Drop
Table 18

Voltage drop for single core LV cables


C.S.A
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

C.S.A
mm 2
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Copper Conductors
Voltage drop ( mV / Amp / Meter )
XLPE Insulated & PVC Sheathed

PVC 85 C Insulated & PVC Sheathed


Flat
Trefoil
22.6
22.5
13.9
13.8
8.7
8.7
5.9
5.48
3.5
3.5
2.3
2.2
1.5
1.5
1.1
1.1
0.83
0.82
0.61
0.60
0.47
0.45
0.39
0.38
0.34
0.33
0.29
0.28
0.25
0.24
0.22
0.21
0.20
0.18
0.18
0.17
0.16
0.15

Trefoil
22.8
14.1
8.8
5.9
3.6
2.3
1.5
1.1
0.83
0.60
0.46
0.38
0.33
0.28
0.24
0.21
0.18
0.16
0.15

Aluminum Conductors
Voltage drop ( mV / Amp / Meter )

PVC 85 C Insulated & PVC Sheathed


Flat
Trefoil
3.7
3.7
2.4
2.3
1.7
1.7
1.3
1.3
0.94
0.92
0.71
0.69
0.58
0.56
0.49
0.48
0.41
0.40
0.34
0.33
0.29
0.28
0.25
0.24
0.22
0.21
0.19
0.18

The above data is based on the following :


Max. operating temp : 90 C for XLPE & 85 C for PVC
Power factor : 0.85
Rated frequency : 60 Hz

83

Flat
22.9
14.1
8.8
5.9
3.6
2.3
1.5
1.1
0.84
0.61
0.47
0.39
0.34
0.29
0.25
0.22
0.19
0.17
0.16

XLPE Insulated & PVC Sheathed


Flat
3.7
2.4
1.8
1.3
0.95
0.71
0.58
0.5
0.42
0.34
0.29
0.25
0.22
0.19

Trefoil
3.7
2.4
1.7
1.3
0.93
0.70
0.57
0.48
0.40
0.33
0.28
0.24
0.21
0.18

Table 19

Voltage drop for multi core LV cables


C.S.A
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500

C.S.A
2
mm
16
25
35
50
70
95
120
150
185
240
300
400
500

Copper Conductors
Voltage drop ( mV / Amp / Meter )
XLPE Insulated & PVC Sheathed

PVC 85 C Insulated & PVC Sheathed


22.5
13.8
8.6
5.8
3.5
2.2
1.4
1.1
0.8
0.58
0.44
0.37
0.32
0.27
0.23
0.20
0.18
0.15

22.8
14.0
8.7
5.9
3.5
2.2
1.5
1.1
0.81
0.58
0.44
0.37
0.31
0.27
0.23
0.2
0.18
0.15

Aluminum Conductors
Voltage drop ( mV / Amp / Meter )
XLPE Insulated & PVC Sheathed

PVC 85 C Insulated & PVC Sheathed


3.6
2.3
1.7
1.3
0.91
0.68
0.55
0.47
0.39
0.32
0.27
0.23
0.20

The above data is based on the following :


Max. operating temp: 90 C for XLPE & 85 C for PVC
Power factor : 0.85
Rated frequency : 60 Hz

3.7
2.4
1.7
1.3
0.92
0.68
0.56
0.47
0.39
0.32
0.27
0.23
0.20

Coding Key
1

The type designation provides information


on the type of cable, the conductor material,
the insulation and sheath materials, the no.
of cores, and the principle design features in
abbreviated and simplified form.
The type designation is made up of 19 digits or
characters. The type of the conductor is
specified first and then the cable construction
from inside to outside.
You can order our product either by giving the
AES item code stated in the catalogue or if the
required cable construction is not included in
our catalogue, you can use the following
codes to determine the type of cable you
require.
1. Type of conductor material
C:

Copper

A:

Aluminum

2. Type of conductor
1:
2:
3:
4:
5:
6:

Solid
Stranded - Circular round
Stranded - Circular compacted
Stranded - Sector shaped
Flexible
Extra-flexible

3 & 4. Size of conductor


08 :
10 :
12 :
13 :
14 :
15 :
16 :
17 :
18 :
19 :
32 :
33 :
34 :
35 :
36 :
37 :
38 :
39 :
40 :
41 :
42 :
43 :
44 :
45 :

85

1.5 mm2
2.5 mm2
4 mm2
6 mm2
10 mm2
16 mm2
25 mm2
35 mm2
50 mm2
70 mm2
3 x 10 + 6 mm2
3 x 16 + 10 mm2
3 x 25 + 16 mm2
3 x 35 + 16 mm2
3 x 50 + 25 mm2
3 x 70 + 35 mm2
3 x 95 + 50 mm2
3 x 120 + 70 mm2
3 x 150 + 70 mm2
3 x 185 + 95 mm2
3 x 240 + 120 mm2
3 x 300 + 150 mm2
3 x 400 + 185 mm2
95 mm2

10

11

12

13

14

15

16

17

18

19

46 :

120 mm2

X:

Lead + Aluminum wire armoured

47 :
48 :
49 :
50 :
51 :
52 :
53 :
54 :
55 :

150 mm2
185 mm2
240 mm2
300 mm2
400 mm2
500 mm2
630 mm2
800 mm2
1000 mm2

R:

Lead + Aluminum tape armoured

5. Type of insulation material


X:
P:
H:

XLPE Insulation
PVC Insulation rated 70 C
PVC Insulation rated 85 C

6. Rated voltage
A:

0.6 / 1 kV

7. Cable construction
1:
2:

Cores
Pairs

8 & 9. Number of cores


01 :

1 Core

02 :
03 :
04 :
05 :

2 Cores
3 Cores
4 Cores
5 Cores

37 :

37 Cores

10. Shielding
N:
C:

Copper tape
Copper wires

0:

Without shielding

11. Armouring
0:
L:
N:
A:
B:
G:
W:

Without armouring
Pure lead sheathed
Lead alloy sheathed
Aluminum wire armoured
Aluminum tape armoured
Galvanized steel tape armoured
Galvanized steel wire armoured

T:
S:

Non-Galva. steel tape armoured


Lead + G. steel tape armoured
Lead + G. steel wire armoured

D:

12. Outer sheath material


C:
M:
L:

PVC Sheath rated 80 C


PVC Sheath rated 90 C
LSHF Sheath rated 90 C

13 & 14. Outer sheath color


BK :

Black

RD :
GY :
GR :
YG :
GL :

Red
Grey
Green
Yellow / Green
Green / Yellow

15 & 16. Core identication


51 :

1C - Red

01 :
04 :
08 :
12 :
21 :

2C - Red, Black
3C - Red, Yellow, Blue
4C - Red, Yellow, Blue, Black
5C - Red, Yellow, Blue, Black, G/Y
6C & Above - Black + No.

Note: The mentioned colors are the most


common for core identification. However,
any other colors for core identification can
be used upon a customers request.

17. Design standard


I:
B:
C:

IEC Standard
BS Standard
Customer request

18. Packing type


M:
T:

Wooden drum
Steel drum

19. Cutting length


S:
F:
R:

250 Meter
500 Meter
1000 Meter

Note: The mentioned cutting lengths are the


most common. However, any other cutting
lengths can be supplied as per a customers
drum schedule.

Selection of Conductor Cross-section


Conductor crosssection should be selected with a sustained current rating under the conditions of installation not less
than the maximum current it will be required to carry during normal operation, and a short circuit current rating
adequate for the prospective shortcircuit current and time for which it may persist.
Especially in lowvoltage networks, it is necessary to check the conductor cross-section, chosen with respect to the
current carrying capacity, by the permissible voltage drop. It is also recommended to carry out this check for long
connections in medium and high voltage networks.

Example for selection of conductor cross-section

0.05 MVA at an operating voltage of 380V have to be transmitted by 4 cores cable with copper conductor, XLPE
insulated and PVC sheathed direct buried in the ground under the following laying conditions :
Burial depth
Soil thermal resistivity
Ambient ground temp.
Cable route length

:
:
:
:

0.5
1.2
35
50

m
K.m/W
C
m

Calculating cross-section according to load current


The load current can be calculated based on the following formula :
I=

Sx10 6

3 xU

0.05 x10 6
3 x380

= 76 A

Where
I : Load current in A
S : KVA rating
U : Line voltage in volts

According to the relevant current carrying capacity values for the used cable type, it has been found that the current
carrying capacity value for 4 X 16 mm2 cable under the required installation conditions is 97A, which is greater than the
required load current (76A). So, cable 4 X 16 mm2 can be used to carry the required load current.
Calculating cross-section according to voltage drop
The tabulated voltage drop values in this catalogue are based on a load power factor of 85% lagging and given for
a current one ampere for a one meter run. For any cable length, the values should be multiplied by the cable route length
in meters and by the load current in amperes.
The applicable formula to calculate the approximate voltage drop/ampere/meter is the following :
V ap =

V p x1000
IxL

mV/Amp/Meter

Where
Vap
I
L
Vp

:
:
:
:

Approximate voltage drop/ampere/meter


Load current in A
Cable route length
Maximum permissible voltage drop (say 2.5% of 380 V)

By substituting current, cable route length, and maximum permissible voltage drop.
Vap =

9.5 x1000
= 2.5 mV/Amp/Meter
76 x50

To determine a suitable size of conductor, select a cable from the voltage drop tables, such that the selected voltage drop
value from the tables is less than the calculated value of 2.5 mv/amp/m. Also ensure that it will carry the desired
current. In this example, the nearest voltage drop value is 2.2 mv/amp/m, which is corresponding to size 16 mm2.
In situations where the load power factor is other than 85% lagging, the voltage drop equations shown in the
formula section should be used to calculate the voltage drop.

Weight-Imperial
v
v

Weight-Metric

Length-Metric

Miscellaneous-Imperial

Area-Imperial

Miscellaneous-Metric
Area-Metric
centimeters

Volume-Imperial
4.54609

Temperature

Lenght-Imperial

87

Volume-U.S.
Volume-Metric

Certicates

1. BASEC (BRITISH APPROVALS SERVICE FOR CABLES)


a. Certicate of conformity, ISO 90012008
b. Certication Schedule
2. Type Test Certicates
Certicates
a. Bare soft copper conductor
b. Power cable with extruded insulation with rated voltage of 0.6 / 1KV
Applicable Standards
a. IEC 60228: 2004
b. IEC 60502-1: 2004
c. IEC 60332-1-2: 2004
d. IEC 60332-3-24: 2000 (Category C)
e. IEC 60332-3-22: 2000 (Category A)

Product Range
manufactures a wide range of low, medium and high voltage electrical products under 50 categories.
Listed below is
s comprehensive product classication:

POWER & CONTROL


Low Voltage Products

Load Center

Circuit Breaker Enclosures (Indoor Outdoor)


Busbar Chamber with Main / Outdoor
Breakers

Low Voltage Systems

Switch Boards MF Type


Distribution Boards MB Type
Motor Control Centres
Capacitor Banks Power Factor Correction Panels
Automatic Transfer Switch (ATS Panels)
Distribution Boards for Substations
Synchronizing Panels
Control & Automation Panels

Package & Unit Substations

Indoor Package Substation

Outdoor Package Substation


Indoor Unit Substation
Outdoor Unit Substation

Medium Voltage Systems

Switchgear (Metal clad, Metal enclosed)


Control gear
Ring Main Unit (RMU)
Retrot solution

METAL ENCLOSURES
Service Box Enclosures
Modular Enclosures
Extendable Cubicles
Telephone Box
Busbar Chamber w/o Main

METAL ACCESSORIES
Switch Boxes
Junction Boxes

89

CABLES & WIRES


Building Wires

American Standards (UL)


British Standards (BS)
International Electro-technical Commission Standards (IEC)

Low Smoke, Halogen Free Wires

Overhead conductors

Bare Stranded Soft Drawn Copper Conductors (SDC)


Bare Stranded Hard Drawn Copper Conductors (HDC)
All Aluminum Conductors (AAC)
All Aluminum Alloy Conductors (AAAC)
Aluminum Conductors, Steel Reinforced (ACSR)
Aluminum Conductors, Aluminum-Clad Steel Reinforced (ACSR / AW)
Aluminum Conductors, Aluminum-Alloy Reinforced (ACAR)
Weather Resistant XLPE Insulated Service Drop Cables

Power Cables

Low Voltage Power & Control Cables


Low Smoke, Halogen Free Cables
Cables for Special Applications

Signal, Communication & Data Cables

Telephone Cables

Coaxial Cables (RG6 / U)


Local Area Network Cables (LAN)

LIGHTING
Halogen
Florescent
Energy Saving

COMMUNICATION SYSTEMS
Audio Intercom

Contact us

markets and sells over 800 electrical construction products in the Saudi Arabian markets and exports them to
several countries in the Middle East, Europe, Asia and Africa.
Through our several operational domains and a widespread network of distributors, we ensure uninterrupted supply of
products. We also provide solutions to our clients including end-users, project owners, engineering contractors
and consultants.
s highly-qualied engineers, sales & marketing teams not only cater to its customers requirements efciently,
they also manage prompt after-sales services and extend full technical support and consultancy services to them.

For more information contact us:

Toll-free No.

800 124 0026

Email: info@alfanar.com
Website: www.alfanar.com

91

Vous aimerez peut-être aussi