Low Voltage
Power and Control Cables
Preface
Low Voltage Power, Control and Special Application Cables are used in various indoor and outdoor
applications in power plants, industries, switchgears, and in railways and trafc signaling systems.
Our products conform to various IEC and BS standards. They are tested at leading international laboratories
and are approved by many utility companies, ministries and major industries.
brand is the manifestation of
s constant endeavor for providing a comprehensive range of
construction materials to satisfy its customers with products of the highest quality standard and safety coupled
with prompt services.
Our cables factory is one of the major industrial units in the ultramodern, fully-integrated
Industrial
Complex.
Industries
s consistent
Group Overview
General Information
Selecting a Power Cable
The following factors are important when selecting a suitable cable construction which is required to
transport electrical energy from the power station to the consumer:
Standards
The cables described in this catalogue are all standard types, and their performance has been proved in
operation. Construction and tests are in accordance with the recommendations of IEC or BS publications
where applicable. Power cables in accordance with other standards ( VDE, NEMA, ICEA ) can be
manufactured upon a customers request.
Jacket Marking
Standard embossed outer jacket marking consisting of:
1.
2.
3.
4.
5.
6.
Name of manufacturer
CABLES
Type designation, size of conductor, rated voltage
ELECTRIC CABLES
Year of manufacture
Continuous length marking every meter
Any special part number, on request
Denitions
Denitions of Dimensional Values
1. Nominal value
Value by which a quantity is designed and which is often used in tables. Usually, in IEC standard, nominal
values give rise to values to be checked by measurements taking into consideration the specied tolerances.
2. Approximate value
Value which is neither guaranteed nor checked; It is used, for example, for the calculation of other dimensional
values.
3. Median value
When several test results have been obtained and sorted in an ascending or descending order, the median
value is the middle value if the number of available values is odd, and the mean of the two middle values if
the number of available values is even.
4. Fictitious value
Value calculated according to the ctitious method described in Annex. A of IEC 60502-1.
Tests made by the manufacturer on each manufactured length of cable to check that each length meets the
specied requirements.
2. Sample tests
Tests made by the manufacturer on samples of completed cable or components taken from a completed
cable, at a specied frequency, so as to verify that the nished product meets the specied requirements.
3. Type tests
Tests made before supplying on a general commercial basis, a type of cable covered by this standard, in order
to demonstrate satisfactory performance characteristics to meet the intended application. These tests are of
such a nature that, after they have been made, they need not be repeated, unless changes are made in the cable
materials or design or manufacturing process, which might change the performance characteristics.
Tests made to demonstrate the integrity of the cable and its accessories after installation.
Power Cables
To IEC Standard
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is
not exposed to mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit for 5 seconds:
Nominal
cross
sectional
area
mm2
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
0.6 / 1 kV
DIMENSIONS AND
WEIGHTS
ELECTRICAL DATA
Max. Conductor
Resistance
DC at
20 C
/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176
AC at
70 C
/ km
5.5100
3.6800
2.1700
1.3700
0.8600
0.6300
0.4600
0.3200
0.2300
0.1900
0.1500
0.1200
0.0920
0.0750
0.0590
0.0480
0.0390
0.0290
0.0250
Current Rating
Laid in ground
Laid in free air
A
42
52
70
90
115
135
160
200
235
270
300
345
400
450
515
580
660
740
820
A
40
50
67
85
110
130
155
190
225
255
285
325
375
420
475
525
590
650
710
A
32
40
52
65
85
105
125
155
185
210
235
270
310
350
390
435
495
555
605
A
37
48
66
80
105
130
160
200
250
285
330
380
480
550
630
720
830
940
1030
A
33
42
58
75
95
125
150
190
240
275
320
370
460
530
615
700
810
920
1010
Approx.
overall
diameter
Approx.
overall
weight
mm
38
7.9
Kg / km
85
115
165
230
345
445
600
805
1085
1350
1655
2030
2675
3280
4350
5355
6685
8600
10500
29
51
65
7.0
8.9
9.9
90
11.6
135
14.6
110
170
210
245
280
320
385
450
520
600
680
775
860
12.7
16.3
18.7
20.4
22.6
24.9
28.3
31.1
35.3
38.8
42.7
47.2
52.0
AES Code
C212PA10100CBK51IMR
C213PA10100CBK51IMR
C314PA10100CBK51IMR
C315PA10100CBK51IMR
C316PA10100CBK51IMR
C317PA10100CBK51IMR
C318PA10100CBK51IMR
C319PA10100CBK51IMR
C345PA10100CBK51IMR
C346PA10100CBK51IMR
C347PA10100CBK51IMR
C348PA10100CBK51IMR
C349PA10100CBK51IMR
C350PA10100CBK51IMR
C351PA10100CBK51IMF
C352PA10100CBK51IMF
C353PA10100CBK51IMF
C354PA10100CBK51IMF
C355PA10100CBK51IMF
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is
not exposed to mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit for 5 seconds:
Nominal
cross
sectional
area
mm2
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
0.6 / 1 kV
DIMENSIONS AND
WEIGHTS
ELECTRICAL DATA
Current Rating
Laid in ground
Laid in free air
Max. Conductor
Resistance
DC at
20 C
/ km
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
0.0778
0.0605
0.0469
0.0367
0.0291
AC at
70 C
/ km
2.2900
1.4400
1.0430
0.7700
0.5330
0.3850
0.3050
0.2480
0.1980
0.1510
0.1220
0.0954
0.0751
0.0595
0.0470
0.0370
65
85
105
125
155
185
210
235
265
310
355
410
465
535
600
665
63
83
102
120
145
175
200
225
255
295
335
380
430
490
530
585
50
65
80
95
120
135
165
180
205
240
270
310
355
405
450
495
65
85
105
125
165
205
235
265
310
365
420
500
580
680
765
840
60
80
100
120
155
195
225
255
300
355
405
480
560
660
745
820
45
65
85
105
125
160
185
210
245
290
335
390
460
535
620
690
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
9.9
11.6
12.7
14.6
16.3
18.7
20.4
22.6
24.8
28.3
31.1
35.3
38.8
42.7
47.2
52.0
135
185
250
295
375
500
605
725
900
1150
1420
1750
2220
2750
3450
4230
AES Code
A315PA10100CBK51IMR
A316PA10100CBK51IMR
A317PA10100CBK51IMR
A318PA10100CBK51IMR
A319PA10100CBK51IMR
A345PA10100CBK51IMR
A346PA10100CBK51IMR
A347PA10100CBK51IMR
A348PA10100CBK51IMR
A349PA10100CBK51IMR
A350PA10100CBK51IMR
A351PA10100CBK51IMR
A352PA10100CBK51IMF
A353PA10100CBK51IMF
A354PA10100CBK51IMF
A355PA10100CBK51IMF
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is
not exposed to mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
12.1000
7.4100
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
14.6000
8.8700
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
1.5
2.5
4
6
10
16
25
35
1.5
2.5
4
6
10
16
25
35
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
sm
12.1000
7.4100
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
14.6000
8.8700
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
20
28
39
50
66
88
116
143
10.1
10.9
12.9
13.9
15.8
17.9
21.3
23.5
120
145
205
255
390
527
770
965
C208PA10200CBK01IMR
10.6
11.5
13.6
14.7
16.9
19.0
22.7
22.8
145
190
270
340
510
710
1050
1360
C208PA10300CBK04IMR
Laid in
free air
19
25
32
40
55
65
85
105
18
23
30
36
48
60
80
95
18
22
31
39
53
72
94
110
AES Code
C210PA10200CBK01IMR
C212PA10200CBK01IMR
C213PA10200CBK01IMR
C314PA10200CBK01IMR
C315PA10200CBK01IMR
C316PA10200CBK01IMR
C317PA10200CBK01IMR
C210PA10300CBK04IMR
C212PA10300CBK04IMR
C213PA10300CBK04IMR
C314PA10300CBK04IMR
C315PA10300CBK04IMR
C316PA10300CBK04IMR
C417PA10300CBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
rm
rm
rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
12.1000
7.4100
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
14.6000
8.8700
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
0.4640
0.3220
0.2320
0.1850
0.1510
0.1210
0.0840
0.0770
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
0.5240 / 1.1500
0.3870 / 0.7270
0.2680 / 0.5240
0.1930 / 0.3870
0.1530 / 0.2680
0.1240 / 0.2680
0.0991 / 0.1930
0.0754 / 0.1530
0.6280 / 1.3900
0.4640 / 0.8700
0.3220 / 0.6280
0.2320 / 0.4640
0.1850 / 0.3220
0.1510 / 0.3220
0.1210 / 0.2320
0.0840 / 0.1850
300 sm
150 sm
0.0601 / 0.1240
Current Rating
Laid in
ground
A
Laid in
ducts
A
18
23
30
36
48
60
80
95
115
145
165
195
220
245
290
320
Approx.
overall
weight
mm
Kg / km
18
22
31
39
53
72
94
110
138
171
209
242
275
314
374
440
11.4
12.4
14.8
16.0
18.5
20.9
25.0
25.1
29.3
32.9
37.8
41.2
45.9
50.7
57.0
63.3
180
230
335
425
650
910
1360
1650
2225
3065
4175
5205
6400
7960
10330
12915
C208PA10400CBK08IMR
1470
2115
2725
3690
4675
5580
7025
9060
C435PA10400CBK08IMR
Laid in
free air
Approx.
overall
diameter
0.0770 / 0.1510
120
145
175
210
240
270
300
345
390
95
115
145
165
195
220
245
290
320
110
138
171
209
242
275
314
374
440
24.0
28.1
31.4
36.1
39.5
43.5
48.2
54.2
60.0
11280
AES Code
C210PA10400CBK08IMR
C212PA10400CBK08IMR
C213PA10400CBK08IMR
C314PA10400CBK08IMR
C315PA10400CBK08IMR
C316PA10400CBK08IMR
C417PA10400CBK08IMR
C418PA10400CBK08IMR
C419PA10400CBK08IMR
C445PA10400CBK08IMR
C446PA10400CBK08IMF
C447PA10400CBK08IMF
C448PA10400CBK08IMF
C449PA10400CBK08IMS
C450PA10400CBK08IMS
C436PA10400CBK08IMR
C437PA10400CBK08IMR
C438PA10400CBK08IMR
C439PA10400CBK08IMF
C440PA10400CBK08IMF
C441PA10400CBK08IMF
C442PA10400CBK08IMS
C443PA10400CBK08IMS
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is
not exposed to mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm2
/ km
/ km
3.0800
1.9100
1.2000
0.8680
3.3000
2.2900
1.4400
1.0430
10
16
25
35
10
16
25
35
11
rm
rm
rm
rm
rm
rm
rm
sm
3.0800
1.9100
1.2000
0.8680
3.3000
2.2900
1.4400
1.0430
Current Rating
Laid in
ground
A
Laid in
ducts
A
39
46
60
83
34
42
56
75
Approx.
overall
weight
mm
Kg / km
46
62
81
114
15.8
17.9
21.3
23.5
290
370
435
505
A314PA10200CBK01IMR
37
50
66
88
16.9
19.0
22.7
22.8
320
405
570
700
A314PA10300CBK04IMR
Laid in
free air
Approx.
overall
diameter
AES Code
A315PA10200CBK01IMR
A316PA10200CBK01IMR
A317PA10200CBK01IMR
A315PA10300CBK04IMR
A316PA10300CBK04IMR
A417PA10300CBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
3.3000
2.2900
1.4400
1.0430
0.7710
0.5330
0.3850
0.3050
0.2490
0.1990
0.1510
0.1230
0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060
1.0430 / 2.2900
0.7710 / 1.4400
0.5330 / 1.0430
0.3850 / 0.7710
0.3050 / 0.5330
0.2490 / 0.5330
0.1990 / 0.3850
0.1510 / 0.3050
0.1230 / 0.2490
10
16
25
35
50
70
95
120
150
185
240
300
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm
Current Rating
Laid in
ground
A
Laid in
ducts
A
34
42
56
75
85
110
130
150
170
195
225
260
Approx.
overall
weight
mm
Kg / km
37
50
66
88
105
132
160
187
215
248
292
347
18.5
20.9
25.0
25.1
29.3
32.9
37.8
41.2
45.9
50.7
57.0
63.3
395
510
715
800
1060
1380
1865
2300
2760
3400
4345
5400
A314PA10400CBK08IMR
725
970
1240
1660
2040
2435
3025
3830
4720
A435PA10400CBK08IMR
Laid in
free air
Approx.
overall
diameter
75
85
110
130
150
170
195
225
260
88
105
132
160
187
215
248
292
347
24.0
28.1
31.4
36.1
39.5
43.5
48.2
54.2
60.0
AES Code
A315PA10400CBK08IMR
A316PA10400CBK08IMR
A417PA10400CBK08IMR
A418PA10400CBK08IMR
A419PA10400CBK08IMR
A445PA10400CBK08IMR
A446PA10400CBK08IMF
A447PA10400CBK08IMF
A448PA10400CBK08IMF
A449PA10400CBK08IMS
A450PA10400CBK08IMS
A436PA10400CBK08IMR
A437PA10400CBK08IMR
A438PA10400CBK08IMR
A439PA10400CBK08IMF
A440PA10400CBK08IMF
A441PA10400CBK08IMF
A442PA10400CBK08IMS
A443PA10400CBK08IMS
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
13
6
10
16
25
35
rm
rm
rm
rm
rm
3.0800
1.8300
1.1500
0.7270
0.5240
3.6900
2.1900
1.3900
0.8700
0.6280
4
6
10
16
25
35
rm
rm
rm
rm
rm
sm
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
50
66
88
116
143
16.9
18.7
20.7
24.1
26.3
460
585
760
1025
1325
C213PA1020GCBK01IMR
16.4
17.5
19.7
21.8
25.5
25.8
440
525
725
950
1340
1560
C212PA1030GCBK04IMR
Laid in
free air
40
55
65
85
105
30
36
48
60
80
95
31
39
53
72
94
110
AES Code
C314PA1020GCBK01IMR
C315PA1020GCBK01IMR
C316PA1020GCBK01IMR
C317PA1020GCBK01IMR
C213PA1030GCBK04IMR
C314PA1030GCBK04IMR
C315PA1030GCBK04IMR
C316PA1030GCBK04IMR
C417PA1030GCBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
0.4640
0.3220
0.2320
0.1850
0.1510
0.1210
0.0840
0.0770
4
6
10
16
25
35
50
70
95
120
150
185
240
300
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm
rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm
0.5240 / 1.1500
0.3870 / 0.7270
0.2680 / 0.5240
0.1930 / 0.3870
0.1530 / 0.2680
0.1240 / 0.2680
0.0991 / 0.1930
0.0754 / 0.1530
0.0601 / 0.1240
Current Rating
Laid in
ground
A
Laid in
ducts
A
30
36
48
60
80
95
115
145
165
195
220
245
290
320
Approx.
overall
weight
mm
Kg / km
31
39
53
72
94
110
138
171
209
242
275
314
374
440
17.6
18.8
21.3
23.7
27.8
27.9
32.7
37.5
42.4
46.2
50.9
56.1
62.6
68.7
520
630
885
1180
1680
1970
2640
3915
5140
6310
7615
9365
12790
14645
C212PA1040GCBK08IMR
1770
2365
3155
4625
5730
6740
8300
10550
12920
C435PA1040GCBK08IMR
Laid in
free air
Approx.
overall
diameter
0.6280 / 1.3900
0.4640 / 0.8700
0.3220 / 0.6280
0.2320 / 0.4640
0.1850 / 0.3220
0.1510 / 0.3220
0.1210 / 0.2320
0.0840 / 0.1850
0.0770 / 0.1510
120
145
175
210
240
270
300
345
390
95
115
145
165
195
220
245
290
320
110
138
171
209
242
275
314
374
440
26.8
30.9
34.6
40.7
44.5
48.5
53.2
59.6
65.4
AES Code
C213PA1040GCBK08IMR
C314PA1040GCBK08IMR
C315PA1040GCBK08IMR
C316PA1040GCBK08IMR
C417PA1040GCBK08IMR
C418PA1040GCBK08IMR
C419PA1040GCBK08IMR
C445PA1040GCBK08IMF
C446PA1040GCBK08IMF
C447PA1040GCBK08IMF
C448PA1040GCBK08IMS
C449PA1040GCBK08IMS
C450PA1040GCBK08IMS
C436PA1040GCBK08IMR
C437PA1040GCBK08IMR
C438PA1040GCBK08IMF
C439PA1040GCBK08IMF
C440PA1040GCBK08IMF
C441PA1040GCBK08IMS
C442PA1040GCBK08IMS
C443PA1040GCBK08IMS
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
3.0800
1.9100
1.2000
0.8680
3.3000
2.2900
1.4400
1.0430
10
16
25
35
10
16
25
35
15
rm
rm
rm
rm
rm
rm
rm
sm
3.0800
1.9100
1.2000
0.8680
3.3000
2.2900
1.4400
1.0430
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
46
62
81
115
16.7
20.7
24.1
26.3
455
540
730
880
A314PA1020GCBK01IMR
19.7
21.8
25.5
25.8
535
625
855
1250
A314PA1030GCBK04IMR
Laid in
free air
39
46
60
83
34
42
56
75
37
50
66
88
AES Code
A315PA1020GCBK01IMR
A316PA1020GCBK01IMR
A317PA1020GCBK01IMR
A315PA1030GCBK04IMR
A316PA1030GCBK04IMR
A417PA1030GCBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
3.3000
2.2900
1.4400
1.0430
0.7710
0.5330
0.3850
0.3050
0.2490
0.1990
0.1510
0.1230
0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060
1.0430 / 2.2900
0.7710 / 1.4400
0.5330 / 1.0430
0.3850 / 0.7710
0.3050 / 0.5330
0.2490 / 0.5330
0.1990 / 0.3850
0.1510 / 0.3050
0.1230 / 0.2490
10
16
25
35
50
70
95
120
150
185
240
300
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm
Current Rating
Laid in
ground
A
Laid in
ducts
A
34
42
56
75
85
110
130
150
170
195
225
260
Approx.
overall
weight
mm
Kg / km
37
50
66
88
105
132
160
187
215
248
292
347
21.3
23.7
27.8
27.9
32.7
37.5
42.4
46.2
50.9
56.1
62.6
68.7
630
775
1035
1115
1475
2225
2830
3360
3975
4815
5925
7125
A314PA1040GCBK08IMR
1030
1330
1675
2585
3100
3590
4300
5325
6365
A435PA1040GCBK08IMR
Laid in
free air
Approx.
overall
diameter
75
85
110
130
150
170
195
225
260
88
105
132
160
187
215
248
292
347
26.8
30.9
34.6
40.7
44.5
48.5
53.2
59.6
65.4
AES Code
A315PA1040GCBK08IMR
A316PA1040GCBK08IMR
A417PA1040GCBK08IMR
A418PA1040GCBK08IMR
A419PA1040GCBK08IMR
A445PA1040GCBK08IMR
A446PA1040GCBK08IMF
A447PA1040GCBK08IMF
A448PA1040GCBK08IMF
A449PA1040GCBK08IMS
A450PA1040GCBK08IMS
A436PA1040GCBK08IMR
A437PA1040GCBK08IMR
A438PA1040GCBK08IMR
A439PA1040GCBK08IMF
A440PA1040GCBK08IMF
A441PA1040GCBK08IMF
A442PA1040GCBK08IMS
A443PA1040GCBK08IMS
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
17
4
6
10
16
25
35
rm
rm
rm
rm
rm
rm
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
4
6
10
16
25
35
rm
rm
rm
rm
rm
sm
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
39
50
66
88
116
143
17.8
18.8
21.6
22.4
26.9
29.5
645
735
800
1085
1760
2120
C212PA1020WCBK01IMR
18.5
19.6
21.8
23.9
28.6
28.8
730
835
1080
1350
1985
2420
C212PA1030WCBK04IMR
Laid in
free air
32
40
55
65
85
105
30
36
48
60
80
100
31
39
53
72
94
110
AES Code
C213PA1020WCBK01IMR
C314PA1020WCBK01IMR
C315PA1020WCBK01IMR
C316PA1020WCBK01IMR
C317PA1020WCBK01IMR
C213PA1030WCBK04IMR
C314PA1030WCBK04IMR
C315PA1030WCBK04IMR
C316PA1030WCBK04IMR
C417PA1030WCBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
0.4640
0.3220
0.2320
0.1850
0.1510
0.1210
0.0840
0.0770
4
6
10
16
25
35
50
70
95
120
150
185
240
300
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm
rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm
0.5240 / 1.1500
0.3870 / 0.7270
0.2680 / 0.5240
0.1930 / 0.3870
0.1530 / 0.2680
0.1240 / 0.2680
0.0991 / 0.1930
0.0754 / 0.1530
0.0601 / 0.1240
Current Rating
Laid in
ground
A
Laid in
ducts
A
29
37
50
68
89
95
115
145
165
195
220
245
290
320
Approx.
overall
weight
mm
Kg / km
29
37
50
68
89
116
143
176
215
248
281
319
380
446
19.7
20.9
23.4
26.5
30.6
30.9
37.1
40.7
46.6
50.6
55.1
60.5
66.8
72.9
840
965
1275
1780
2380
2690
3870
4900
6665
7990
9445
11425
14205
17870
C212PA1040WCBK08IMR
2460
3550
4480
5475
7385
8505
10260
12755
15330
C435PA1040WCBK08IMR
Laid in
free air
Approx.
overall
diameter
0.6280 / 1.3900
0.4640 / 0.8700
0.3220 / 0.6280
0.2320 / 0.4640
0.1850 / 0.3220
0.1510 / 0.3220
0.1210 / 0.2320
0.0840 / 0.1850
0.0770 / 0.1510
120
145
175
210
240
270
300
345
390
95
115
145
165
195
220
245
290
320
116
143
176
215
248
281
319
380
446
29.8
35.5
39.2
42.6
48.9
52.7
57.6
64.0
69.8
AES Code
C213PA1040WCBK08IMR
C314PA1040WCBK08IMR
C315PA1040WCBK08IMR
C316PA1040WCBK08IMR
C417PA1040WCBK08IMR
C418PA1040WCBK08IMR
C419PA1040WCBK08IMR
C445PA1040WCBK08IMF
C446PA1040WCBK08IMF
C447PA1040WCBK08IMF
C448PA1040WCBK08IMS
C449PA1040WCBK08IMS
C450PA1040WCBK08IMS
C436PA1040WCBK08IMR
C437PA1040WCBK08IMR
C438PA1040WCBK08IMF
C439PA1040WCBK08IMF
C440PA1040WCBK08IMF
C441PA1040WCBK08IMS
C442PA1040WCBK08IMS
C443PA1040WCBK08IMS
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
3.0800
1.9100
1.2000
0.8680
3.3000
2.2900
1.4400
1.0430
10
16
25
35
10
16
25
35
19
rm
rm
rm
rm
rm
rm
rm
sm
3.0800
1.9100
1.2000
0.8680
3.3000
2.2900
1.4400
1.0430
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
46
62
81
115
21.6
22.4
26.9
29.5
680
825
1450
2250
A314PA1020WCBK01IMR
21.8
23.9
28.6
28.8
915
1525
1875
2330
A314PA1030WCBK04IMR
Laid in
free air
39
46
60
83
34
42
56
75
37
50
66
88
AES Code
A315PA1020WCBK01IMR
A316PA1020WCBK01IMR
A317PA1020WCBK01IMR
A315PA1030WCBK04IMR
A316PA1030WCBK04IMR
A417PA1030WCBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
Current Rating
/ km
Laid in
ground
A
Laid in
ducts
A
Laid in
free air
A
42
53
70
95
115
135
165
185
210
235
275
310
34
42
56
75
85
110
130
150
170
195
225
260
37
50
66
88
105
138
165
193
220
253
297
352
10
16
25
35
50
70
95
120
150
185
240
300
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
3.3000
2.2900
1.4400
1.0430
0.7710
0.5330
0.3850
0.3050
0.2490
0.1990
0.1510
0.1230
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm
0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060
1.0430 / 2.2900
0.7710 / 1.4400
0.5330 / 1.0430
0.3850 / 0.7710
0.3050 / 0.5330
0.2490 / 0.5330
0.1990 / 0.3850
0.1510 / 0.3050
0.1230 / 0.2490
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
23.4
26.5
30.6
30.9
37.1
40.7
46.6
50.6
55.1
60.5
66.8
72.9
1420
1720
2110
1780
3040
3750
4730
5570
6430
7790
9180
10590
A314PA1040WCBK08IMR
1550
2300
2820
3410
4370
5080
5950
7230
8540
A435PA1040WCBK08IMR
75
85
110
130
150
170
195
225
260
94
110
138
165
193
220
253
297
352
29.8
35.5
39.2
42.6
48.9
52.7
57.6
64.0
69.8
AES Code
A315PA1040WCBK08IMR
A316PA1040WCBK08IMR
A417PA1040WCBK08IMR
A418PA1040WCBK08IMR
A419PA1040WCBK08IMR
A445PA1040WCBK08IMR
A446PA1040WCBK08IMF
A447PA1040WCBK08IMF
A448PA1040WCBK08IMF
A449PA1040WCBK08IMS
A450PA1040WCBK08IMS
A436PA1040WCBK08IMR
A437PA1040WCBK08IMR
A438PA1040WCBK08IMR
A439PA1040WCBK08IMF
A440PA1040WCBK08IMF
A441PA1040WCBK08IMF
A442PA1040WCBK08IMS
A443PA1040WCBK08IMS
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is not
exposed to mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
21
Nominal
cross
sectional
area
mm2
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
0.6 / 1 kV
DIMENSIONS AND
WEIGHTS
ELECTRICAL DATA
Current Rating
Laid in ground
Laid in free air
Max. Conductor
Resistance
DC at
20 C
/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176
AC at
90 C
/ km
5.8800
3.9300
2.3300
1.4700
0.9270
0.6690
0.4940
0.3430
0.2480
0.1970
0.1600
0.1290
0.0990
0.0810
0.0638
0.0517
0.0425
0.0292
0.0234
55
68
98
116
150
179
210
263
310
357
394
452
520
588
672
761
872
957
1082
51
65
86
111
142
172
200
247
294
336
373
425
488
546
620
693
777
861
935
40
53
68
87
110
137
163
200
242
273
310
352
404
457
515
572
651
735
798
53
65
84
116
143
179
221
278
347
404
457
530
651
824
893
1008
1155
1313
1449
47
59
79
110
137
173
210
268
336
394
446
520
641
756
872
987
1134
1292
1428
40
53
68
95
121
152
184
236
289
341
389
441
536
620
714
814
956
1092
1208
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
6.8
7.3
8.3
9.3
11.0
12.1
13.8
15.7
17.7
19.6
21.8
23.9
27.1
29.7
33.9
37.4
41.9
46.8
51.5
80
102
150
210
315
410
555
760
1015
1280
1570
1920
2530
3105
4135
5110
6455
8260
10075
AES Code
C212XA10100MBK51IMR
C213XA10100MBK51IMR
C314XA10100MBK51IMR
C315XA10100MBK51IMR
C316XA10100MBK51IMR
C317XA10100MBK51IMR
C318XA10100MBK51IMR
C319XA10100MBK51IMR
C345XA10100MBK51IMR
C346XA10100MBK51IMR
C347XA10100MBK51IMR
C348XA10100MBK51IMR
C349XA10100MBK51IMR
C350XA10100MBK51IMR
C351XA10100MBK51IMF
C352XA10100MBK51IMF
C353XA10100MBK51IMF
C354XA10100MBK51IMF
C355XA10100MBK51IMF
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is not
exposed to mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
23
Nominal
cross
sectional
area
mm2
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
0.6 / 1 kV
DIMENSIONS AND
WEIGHTS
ELECTRICAL DATA
Current Rating
Laid in ground
Laid in free air
Max. Conductor
Resistance
DC at
20 C
/ km
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
0.0778
0.0605
0.0469
0.0367
0.0291
AC at
90 C
/ km
2.4500
1.5400
1.1130
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310
0.1000
0.0870
0.0620
0.0560
0.0470
89
113
137
163
200
236
278
310
352
410
467
541
609
698
788
872
87
110
131
155
189
226
263
294
336
389
436
504
567
646
704
767
66
84
105
121
152
179
215
236
267
315
357
410
467
536
599
651
89
116
142
173
221
284
326
373
436
515
578
693
809
945
1071
1176
84
110
137
168
215
273
315
362
420
499
567
677
788
924
1050
1155
63
95
121
147
179
215
242
299
336
399
462
541
630
746
851
966
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
9.3
11.0
12.1
13.8
15.7
17.7
19.6
21.8
23.9
27.1
29.7
33.9
37.4
41.9
46.8
51.5
115
165
205
260
340
450
550
670
830
1050
1300
1610
2000
2520
3150
3870
AES Code
A315XA10100MBK51IMR
A316XA10100MBK51IMR
A317XA10100MBK51IMR
A318XA10100MBK51IMR
A319XA10100MBK51IMR
A345XA10100MBK51IMR
A346XA10100MBK51IMR
A347XA10100MBK51IMR
A348XA10100MBK51IMR
A349XA10100MBK51IMR
A350XA10100MBK51IMR
A351XA10100MBK51IMR
A352XA10100MBK51IMF
A353XA10100MBK51IMF
A354XA10100MBK51IMF
A355XA10100MBK51IMF
0.6 / 1 kV
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is not
exposed to mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm
/ km
/ km
27
10
16
25
35
rm
rm
rm
rm
3.0800
1.9100
1.2000
0.8680
3.9500
2.4500
1.5400
1.1130
10
16
25
35
rm
rm
rm
sm
3.0800
1.9100
1.2000
0.8680
3.9500
2.4500
1.5400
1.1130
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
55
73
97
120
14.7
16.7
20.1
22.3
335
450
640
780
A314XA10200MBK01IMR
15.6
17.7
21.4
21.5
375
605
835
1050
A314XA10300MBK04IMR
Laid in
free air
48
58
75
106
42
52
71
95
48
62
84
105
AES Code
A315XA10200MBK01IMR
A316XA10200MBK01IMR
A317XA10200MBK01IMR
A315XA10300MBK04IMR
A316XA10300MBK04IMR
A417XA10300MBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm
/ km
/ km
3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
3.9500
2.4500
1.5400
1.1130
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310
0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060
1.1130 / 2.4500
0.8220 / 1.5400
0.5690 / 1.1130
0.4110 / 0.8220
0.3250 / 0.5690
0.2650 / 0.5690
10
16
25
35
50
70
95
120
150
185
240
300
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm
Current Rating
Laid in
ground
A
Laid in
ducts
A
42
52
71
95
110
140
165
190
215
240
280
315
Approx.
overall
weight
mm
Kg / km
48
62
84
110
136
168
205
236
278
315
378
446
17.0
19.4
23.5
23.6
27.1
31.4
35.1
39.2
43.7
48.7
54.5
60.1
450
700
925
800
950
1260
1650
2060
2520
3140
4020
4930
A314PA10400MBK08IMR
610
925
1255
1630
2030
2515
3095
3900
4795
A435XA10400MBK08IMR
Laid in
free air
Approx.
overall
diameter
0.2120 / 0.4110
0.1630 / 0.3250
0.1310 / 0.2650
121
145
178
214
243
272
309
359
406
96
116
142
171
195
220
250
292
331
110
136
171
211
246
282
326
388
449
22.5
25.9
29.7
33.6
37.5
41.3
46.2
51.5
56.8
AES Code
A315PA10400MBK08IMR
A316PA10400MBK08IMR
A417PA10400MBK08IMR
A418PA10400MBK08IMR
A419PA10400MBK08IMR
A445XA10400MBK08IMR
A446XA10400MBK08IMF
A447XA10400MBK08IMF
A448XA10400MBK08IMF
A449XA10400MBK08IMS
A450XA10400MBK08IMS
A436XA10400MBK08IMR
A437XA10400MBK08IMR
A438XA10400MBK08IMR
A439XA10400MBK08IMF
A440XA10400MBK08IMF
A441XA10400MBK08IMF
A442XA10400MBK08IMS
A443XA10400MBK08IMS
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm2
/ km
/ km
3.0800
1.8300
1.1500
0.7270
0.5240
3.9300
2.3300
1.4700
0.9270
0.6690
6
10
16
25
35
6
10
16
25
35
29
rm
rm
rm
rm
rm
rm
rm
rm
rm
sm
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
59
78
103
137
164
15.5
17.5
19.5
22.1
23.8
405
530
685
930
1245
C213XA1020GMBK01IMR
16.2
18.4
20.5
24.2
22.8
465
650
870
1235
1370
C213XA1030GMBK04IMR
Laid in
free air
51
68
82
106
132
AES Code
C314XA1020GMBK01IMR
C315XA1020GMBK01IMR
C316XA1020GMBK01IMR
C317XA1020GMBK01IMR
3.9300
2.3300
1.4700
0.9270
0.6690
56
74
96
127
153
44
59
74
100
119
49
67
88
120
143
C314XA1030GMBK04IMR
C315XA1030GMBK04IMR
C316XA1030GMBK04IMR
C417XA1030GMBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm
/ km
/ km
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
3.9300
2.3300
1.4700
0.9270
0.6690
0.4940
0.3430
0.2480
0.1970
0.1600
0.1290
0.0990
0.0810
6
10
16
25
35
50
70
95
120
150
185
240
300
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm
0.5240 / 1.1500
0.3870 / 0.7270
0.2680 / 0.5240
0.1930 / 0.3870
0.1530 / 0.2680
0.1240 / 0.2680
0.0991 / 0.1930
0.0754 / 0.1530
0.0601 / 0.1240
Current Rating
Laid in
ground
A
Laid in
ducts
A
44
59
74
100
119
145
180
210
245
275
310
365
405
Approx.
overall
weight
mm
Kg / km
49
67
88
120
143
178
215
268
310
352
404
483
562
17.4
19.8
22.2
26.3
26.4
30.1
34.6
39.7
43.8
48.7
53.7
60.0
65.5
555
795
1075
1540
1830
2415
3335
4815
5910
7195
8830
11285
13835
C213XA1040GMBK08IMR
1640
2160
2960
4280
5365
6355
7865
10000
12205
C435XA1040GMBK08IMR
Laid in
free air
Approx.
overall
diameter
0.6690 / 1.4700
0.4940 / 0.9270
0.3430 / 0.6690
0.2480 / 0.4940
0.1970 / 0.3430
0.1600 / 0.3430
0.1290 / 0.2480
0.0990 / 0.1970
0.0810 / 0.1600
153
185
220
265
305
335
375
435
490
119
145
180
210
245
275
310
365
405
143
178
215
268
310
352
404
483
562
25.3
28.7
33.1
38.0
42.1
46.3
51.2
57.1
62.2
AES Code
C314XA1040GMBK08IMR
C315XA1040GMBK08IMR
C316XA1040GMBK08IMR
C417XA1040GMBK08IMR
C418XA1040GMBK08IMR
C419XA1040GMBK08IMR
C445XA1040GMBK08IMF
C446XA1040GMBK08IMF
C447XA1040GMBK08IMF
C448XA1040GMBK08IMS
C449XA1040GMBK08IMS
C450XA1040GMBK08IMS
C436XA1040GMBK08IMR
C437XA1040GMBK08IMR
C438XA1040GMBK08IMF
C439XA1040GMBK08IMF
C440XA1040GMBK08IMF
C441XA1040GMBK08IMS
C442XA1040GMBK08IMS
C443XA1040GMBK08IMS
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm2
/ km
/ km
3.0800
1.9100
1.2000
0.8680
3.9500
2.4500
1.5400
1.1130
10
16
25
35
10
16
25
35
31
rm
rm
rm
rm
rm
rm
rm
sm
3.0800
1.9100
1.2000
0.8680
3.9500
2.4500
1.5400
1.1130
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
55
72
96
126
17.5
19.5
22.1
25.1
480
595
810
950
A314XA1020GMBK01IMR
18.4
20.5
24.2
24.5
555
685
925
1110
A314XA1030GMBK04IMR
Laid in
free air
47
57
74
105
41
52
70
95
47
62
84
110
AES Code
A315XA1020GMBK01IMR
A316XA1020GMBK01IMR
A317XA1020GMBK01IMR
A315XA1030GMBK04IMR
A316XA1030GMBK04IMR
A417XA1030GMBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm
/ km
/ km
3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
3.9500
2.4500
1.5400
1.1130
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310
0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060
1.1130 / 2.4500
0.8220 / 1.5400
0.5690 / 1.1130
0.4110 / 0.8220
0.3250 / 0.5690
0.2650 / 0.5690
0.2120 / 0.4110
0.1630 / 0.3250
0.1310 / 0.2650
10
16
25
35
50
70
95
120
150
185
240
300
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm
Current Rating
Laid in
ground
A
Laid in
ducts
A
41
52
70
95
110
140
165
190
215
240
280
315
Approx.
overall
weight
mm
Kg / km
47
62
84
110
136
168
205
236
278
315
378
446
19.8
22.2
26.3
26.4
30.1
34.6
39.7
43.8
48.7
53.7
60.0
65.5
635
795
1090
970
1490
1750
2540
3020
3670
4380
4430
6510
A314XA1040GMBK08IMR
895
1200
1550
1970
2710
3290
3980
4910
5920
A435XA1040GMBK08IMR
Laid in
free air
Approx.
overall
diameter
95
110
140
165
190
215
240
280
315
110
136
168
205
236
278
315
378
446
25.3
28.7
33.1
38.0
42.1
46.3
51.2
57.1
62.2
AES Code
A315XA1040GMBK08IMR
A316XA1040GMBK08IMR
A417XA1040GMBK08IMR
A418XA1040GMBK08IMR
A419XA1040GMBK08IMR
A445XA1040GMBK08IMR
A446XA1040GMBK08IMF
A447XA1040GMBK08IMF
A448XA1040GMBK08IMF
A449XA1040GMBK08IMS
A450XA1040GMBK08IMS
A436XA1040GMBK08IMR
A437XA1040GMBK08IMR
A438XA1040GMBK08IMR
A439XA1040GMBK08IMF
A440XA1040GMBK08IMF
A441XA1040GMBK08IMF
A442XA1040GMBK08IMS
A443XA1040GMBK08IMS
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm2
/ km
/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
5.8800
3.9300
2.3300
1.4700
0.9270
0.6690
4
6
10
16
25
35
4
6
10
16
25
35
33
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
sm
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
5.8800
3.9300
2.3300
1.4700
0.9270
0.6690
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
47
61
80
106
140
168
16.6
17.6
19.6
21.6
24.2
27.5
580
660
835
1020
1335
1755
C212XA1020WMBK01IMR
17.2
18.3
20.5
22.6
27.0
27.3
650
755
965
1240
1850
2220
C212XA1030WMBK04IMR
Laid in
free air
41
53
70
84
108
135
37
46
61
76
103
122
42
51
69
90
120
147
AES Code
C213XA1020WMBK01IMR
C314XA1020WMBK01IMR
C315XA1020WMBK01IMR
C316XA1020WMBK01IMR
C317XA1020WMBK01IMR
C213XA1030WMBK04IMR
C314XA1030WMBK04IMR
C315XA1030WMBK04IMR
C316XA1030WMBK04IMR
C417XA1030WMBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm
/ km
/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
5.8800
3.9300
2.3300
1.4700
0.9270
0.6690
0.4940
0.3430
0.2480
0.1970
0.1600
0.1290
0.0990
0.0810
4
6
10
16
25
35
50
70
95
120
150
185
240
300
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm
rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm
0.5240 / 1.1500
0.3870 / 0.7270
0.2680 / 0.5240
0.1930 / 0.3870
0.1530 / 0.2680
0.1240 / 0.2680
0.0991 / 0.1930
0.0754 / 0.1530
0.0601 / 0.1240
Current Rating
Laid in
ground
A
Laid in
ducts
A
37
46
61
76
103
122
145
180
210
245
275
310
365
405
Approx.
overall
weight
mm
Kg / km
42
51
69
90
122
147
184
220
273
315
375
410
488
562
18.3
19.5
21.9
25.0
29.1
29.4
33.1
39.2
42.9
48.4
53.1
57.9
64.1
69.7
740
860
1155
1630
2220
2520
3200
4645
5870
7555
8985
10760
13480
16215
C212XA1040WMBK08IMR
2250
2860
4240
5290
6475
8055
9735
11780
14435
C435XA1040WMBK08IMR
Laid in
free air
Approx.
overall
diameter
0.6690 / 1.4700
0.4940 / 0.9270
0.3430 / 0.6690
0.2480 / 0.4940
0.1970 / 0.3430
0.1600 / 0.3430
0.1290 / 0.2480
0.0990 / 0.1970
0.0810 / 0.1600
158
185
220
265
305
335
375
435
490
122
145
180
210
245
275
310
365
405
147
184
220
273
315
375
410
488
562
27.7
31.3
37.5
41.2
45.3
50.5
55.4
60.3
66.4
AES Code
C213XA1040WMBK08IMR
C314XA1040WMBK08IMR
C315XA1040WMBK08IMR
C316XA1040WMBK08IMR
C417XA1040WMBK08IMR
C418XA1040WMBK08IMR
C419XA1040WMBK08IMR
C445XA1040WMBK08IMF
C446XA1040WMBK08IMF
C447XA1040WMBK08IMF
C448XA1040WMBK08IMS
C449XA1040WMBK08IMS
C450XA1040WMBK08IMS
C436XA1040WMBK08IMR
C437XA1040WMBK08IMR
C438XA1040WMBK08IMF
C439XA1040WMBK08IMF
C440XA1040WMBK08IMF
C441XA1040WMBK08IMS
C442XA1040WMBK08IMS
C443XA1040WMBK08IMS
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm2
/ km
/ km
3.0800
1.9100
1.2000
0.8680
3.9500
2.4500
1.5400
1.1130
10
16
25
35
10
16
25
35
35
rm
rm
rm
rm
rm
rm
rm
sm
3.0800
1.9100
1.2000
0.8680
3.9500
2.4500
1.5400
1.1130
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
60
79
101
131
19.6
21.6
24.2
27.5
635
770
1370
1560
A314XA1020WMBK01IMR
20.5
22.6
27.0
27.3
715
870
1515
1770
A314XA1030WMBK04IMR
Laid in
free air
47
57
74
105
41
52
70
95
52
67
89
115
AES Code
A315XA1020WMBK01IMR
A316XA1020WMBK01IMR
A317XA1020WMBK01IMR
A315XA1030WMBK04IMR
A316XA1030WMBK04IMR
A417XA1030WMBK04IMR
0.6 / 1 kV
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm
/ km
/ km
3.0800
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
3.9500
2.4500
1.5400
1.1130
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310
0.8680 / 1.9100
0.6410 / 1.2000
0.4430 / 0.8680
0.3200 / 0.6410
0.2530 / 0.4430
0.2060 / 0.4430
0.1640 / 0.3200
0.1250 / 0.2530
0.1000 / 0.2060
1.1130 / 2.4500
0.8220 / 1.5400
0.5690 / 1.1130
0.4110 / 0.8220
0.3250 / 0.5690
0.2650 / 0.5690
0.2120 / 0.4110
0.1630 / 0.3250
0.1310 / 0.2650
10
16
25
35
50
70
95
120
150
185
240
300
35 sm
50 sm
70 sm
95 sm
120 sm
150 sm
185 sm
240 sm
300 sm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
16 rm
25 rm
35 sm
50 sm
70 sm
70 sm
95 sm
120 sm
150 sm
Current Rating
Laid in
ground
A
Laid in
ducts
A
41
52
70
95
110
140
165
190
215
240
280
315
Approx.
overall
weight
mm
Kg / km
52
67
89
115
141
173
210
241
283
320
383
451
21.9
25.0
29.1
29.4
33.1
39.2
42.9
48.4
53.1
57.9
64.1
69.7
785
1335
1630
1700
2330
2760
3340
4320
5080
5990
7220
8440
A314XA1040WMBK08IMR
1500
1870
2600
3090
3690
4700
5550
6560
7820
A435XA1040WMBK08IMR
Laid in
free air
Approx.
overall
diameter
95
110
140
165
190
215
240
280
315
115
141
173
210
241
283
320
383
451
27.7
31.3
37.5
41.2
45.3
50.5
55.4
60.3
66.4
AES Code
A315XA1040WMBK08IMR
A316XA1040WMBK08IMR
A417XA1040WMBK08IMR
A418XA1040WMBK08IMR
A419XA1040WMBK08IMR
A445XA1040WMBK08IMR
A446XA1040WMBK08IMF
A447XA1040WMBK08IMF
A448XA1040WMBK08IMF
A449XA1040WMBK08IMS
A450XA1040WMBK08IMS
A436XA1040WMBK08IMR
A437XA1040WMBK08IMR
A438XA1040WMBK08IMR
A439XA1040WMBK08IMF
A440XA1040WMBK08IMF
A441XA1040WMBK08IMF
A442XA1040WMBK08IMS
A443XA1040WMBK08IMS
Control Cables
To IEC Standard
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors in cable trenches or ducts; and outdoors - for connecting signaling and control
units in industries, railways, trafc signals, power stations, industrial plants and switchgears if
mechanical protection is not required, or in applications where the cable is not exposed to
mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
37
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
Current Rating
Laid in
ground
A
Laid in
ducts
A
1.5 mm2
18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0
11.8
12.7
15.7
16.2
17.0
17.8
18.7
21.7
23.8
24.7
200
250
340
385
435
490
560
700
850
1000
Laid in
free air
AES Code
C108PA10500CBK12IMR
C108PA10700CBK21IMR
C108PA11000CBK21IMR
C108PA11200CBK21IMR
C108PA11400CBK21IMR
C108PA11600CBK21IMR
C108PA11900CBK21IMR
C108PA12400CBK21IMF
C108PA13000CBK21IMF
C108PA13700CBK21IMF
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
2
0.6 / 1 kV
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
Current Rating
Laid in
ground
A
24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0
31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0
Laid in
ducts
A
2.5 mm
20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0
4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5
12.9
13.8
17.2
17.7
18.6
19.6
20.6
24.0
25.4
27.4
260
330
450
540
600
670
780
1030
1160
1410
C110PA10500CBK12IMR
24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0
15.3
16.5
20.8
21.5
22.6
23.8
25.1
29.6
31.6
34.1
430
480
670
780
890
1000
1170
1460
1830
2320
C112PA10500CBK12IMR
Laid in
free air
AES Code
C110PA10700CBK21IMR
C110PA11000CBK21IMR
C110PA11200CBK21IMR
C110PA11400CBK21IMR
C110PA11600CBK21IMR
C110PA11900CBK21IMR
C110PA12400CBK21IMF
C110PA13000CBK21IMF
C110PA13700CBK21IMF
C112PA10700CBK21IMR
C112PA11000CBK21IMR
C112PA11200CBK21IMR
C112PA11400CBK21IMR
C112PA11600CBK21IMR
C112PA11900CBK21IMR
C112PA12400CBK21IMF
C112PA13000CBK21IMF
C112PA13700CBK21IMF
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors in cable trenches or ducts; and outdoors - for connecting signaling and control
units in industries, railways, trafc signals, power stations, industrial plants and switchgears if
mechanical protection is not required, or in applications where the cable is not exposed to
mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
39
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
Current Rating
Laid in
ground
A
Laid in
ducts
A
1.5 mm2
18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0
12.3
13.3
16.5
17.0
17.8
18.7
19.7
22.9
24.2
26.1
215
265
360
410
465
530
600
740
890
1070
Laid in
free air
AES Code
C208PA10500CBK12IMR
C208PA10700CBK21IMR
C208PA11000CBK21IMR
C208PA11200CBK21IMR
C208PA11400CBK21IMR
C208PA11600CBK21IMR
C208PA11900CBK21IMR
C208PA12400CBK21IMF
C208PA13000CBK21IMF
C208PA13700CBK21IMF
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
2
0.6 / 1 kV
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
Current Rating
Laid in
ground
A
Laid in
ducts
2.5 mm
24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0
20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0
4.0 mm2
31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5
13.4
14.5
18.1
18.7
19.6
20.6
21.7
25.3
26.8
28.9
275
350
480
555
630
710
820
1020
1235
1495
C210PA10500CBK12IMR
24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0
16.1
17.4
22.0
22.7
23.9
25.2
26.6
31.4
33.5
36.2
410
520
720
840
950
1070
1260
1580
1965
2510
C212PA10500CBK12IMR
Laid in
free air
AES Code
C210PA10700CBK21IMR
C210PA11000CBK21IMR
C210PA11200CBK21IMR
C210PA11400CBK21IMR
C210PA11600CBK21IMR
C210PA11900CBK21IMR
C210PA12400CBK21IMF
C210PA13000CBK21IMF
C210PA13700CBK21IMF
C212PA10700CBK21IMR
C212PA11000CBK21IMR
C212PA11200CBK21IMR
C212PA11400CBK21IMR
C212PA11600CBK21IMR
C212PA11900CBK21IMR
C212PA12400CBK21IMF
C212PA13000CBK21IMF
C212PA13700CBK21IMF
CONSTRUCTION
Conductor
Insulation
Bedding
Shielding
Outer sheath :
APPLICATION
For use indoors in cable trenches or ducts; and outdoors - for connecting signaling and control
units in industries, railways, trafc signals, power stations, industrial plants and switchgears if
mechanical protection is not required, or in applications where the cable is not exposed to
mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
41
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
No. X mm2
/ km
/ km
5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
Current Rating
Laid in
ground
A
18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5
Laid in
ducts
A
1.5 mm2
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0
14.2
15.1
18.1
18.6
19.4
20.2
21.1
25.3
27.5
29.4
305
350
465
520
575
635
715
930
1115
1205
Laid in
free air
AES Code
C108PA105N0CBK12IMR
C108PA107N0CBK21IMR
C108PA110N0CBK21IMR
C108PA112N0CBK21IMR
C108PA114N0CBK21IMR
C108PA116N0CBK21IMR
C108PA119N0CBK21IMR
C108PA124N0CBK21IMF
C108PA130N0CBK21IMF
C108PA137N0CBK21IMF
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
2
0.6 / 1 kV
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
Current Rating
Laid in
ground
A
24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0
31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0
Laid in
ducts
A
2.5 mm
20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0
4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5
15.1
16.2
19.6
20.1
21.0
22.0
23.0
26.4
27.8
30.0
380
450
560
650
750
830
970
1260
1380
1670
C110PA105N0CBK12IMR
24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0
18.5
19.9
23.2
23.9
25.0
26.2
27.5
32.0
34.0
36.7
540
670
800
920
1080
1230
1430
1780
2210
2790
C112PA105N0CBK12IMR
Laid in
free air
AES Code
C110PA107N0CBK21IMR
C110PA110N0CBK21IMR
C110PA112N0CBK21IMR
C110PA114N0CBK21IMR
C110PA116N0CBK21IMR
C110PA119N0CBK21IMR
C110PA124N0CBK21IMF
C110PA130N0CBK21IMF
C110PA137N0CBK21IMF
C112PA107N0CBK21IMR
C112PA110N0CBK21IMR
C112PA112N0CBK21IMR
C112PA114N0CBK21IMR
C112PA116N0CBK21IMR
C112PA119N0CBK21IMR
C112PA124N0CBK21IMF
C112PA130N0CBK21IMF
C112PA137N0CBK21IMF
CONSTRUCTION
Conductor
Insulation
Bedding
Shielding
Outer sheath :
APPLICATION
For use indoors in cable trenches or ducts; and outdoors - for connecting signaling and control
units in industries, railways, trafc signals, power stations, industrial plants and switchgears if
mechanical protection is not required, or in applications where the cable is not exposed to
mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
43
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
No. X mm2
/ km
/ km
5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
Current Rating
Laid in
ground
A
18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5
Laid in
ducts
A
1.5 mm2
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0
15.7
16.5
18.9
19.4
20.2
21.1
22.1
25.3
27.5
28.5
340
370
495
550
610
670
760
930
1115
1290
Laid in
free air
AES Code
C208PA105N0CBK12IMR
C208PA107N0CBK21IMR
C208PA110N0CBK21IMR
C208PA112N0CBK21IMR
C208PA114N0CBK21IMR
C208PA116N0CBK21IMR
C208PA119N0CBK21IMR
C208PA124N0CBK21IMF
C208PA130N0CBK21IMF
C208PA137N0CBK21IMF
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
2
0.6 / 1 kV
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
Current Rating
Laid in
ground
A
24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0
31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0
Laid in
ducts
A
2.5 mm
20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0
4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5
15.8
16.9
20.5
21.1
22.0
23.0
24.1
27.7
26.8
31.5
390
470
630
710
800
875
1000
1225
1240
1750
C210PA105N0CBK12IMR
24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0
18.5
19.9
24.4
25.2
26.3
27.6
29.0
33.8
35.9
38.8
540
670
850
980
1160
1310
1520
1900
2350
2970
C212PA105N0CBK12IMR
Laid in
free air
AES Code
C210PA107N0CBK21IMR
C210PA110N0CBK21IMR
C210PA112N0CBK21IMR
C210PA114N0CBK21IMR
C210PA116N0CBK21IMR
C210PA119N0CBK21IMR
C210PA124N0CBK21IMF
C210PA130N0CBK21IMF
C210PA137N0CBK21IMF
C212PA107N0CBK21IMR
C212PA110N0CBK21IMR
C212PA112N0CBK21IMR
C212PA114N0CBK21IMR
C212PA116N0CBK21IMR
C212PA119N0CBK21IMR
C212PA124N0CBK21IMF
C212PA130N0CBK21IMF
C212PA137N0CBK21IMF
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations, for connecting signaling and control units in industries, railways,
trafc signals, power stations, industrial plants and switchgears if mechanical protection is
required, or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
45
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
No. X mm2
/ km
/ km
5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
Current Rating
Laid in
ground
A
18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5
Laid in
ducts
A
1.5 mm2
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0
15.0
15.5
18.5
19.0
20.6
21.0
21.5
24.5
25.8
27.5
355
410
540
590
670
720
800
970
1170
1315
Laid in
free air
AES Code
C108PA1050GCBK12IMR
C108PA1070GCBK21IMR
C108PA1100GCBK21IMR
C108PA1120GCBK21IMR
C108PA1140GCBK21IMR
C108PA1160GCBK21IMR
C108PA1190GCBK21IMR
C108PA1240GCBK21IMF
C108PA1300GCBK21IMF
C108PA1370GCBK21IMF
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
2
0.6 / 1 kV
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
Current Rating
Laid in
ground
A
24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0
31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0
Laid in
ducts
A
2.5 mm
20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0
4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5
15.5
16.6
20.0
20.5
21.4
22.4
23.4
27.0
28.2
30.5
340
495
650
760
820
920
1030
1260
1520
1830
C110PA1050GCBK12IMR
24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0
18.9
20.3
23.6
24.1
25.4
26.6
28.1
32.6
34.4
37.3
610
710
890
1140
1180
1300
1500
1890
2480
3030
C112PA1050GCBK12IMR
Laid in
free air
AES Code
C110PA1070GCBK21IMR
C110PA1100GCBK21IMR
C110PA1120GCBK21IMR
C110PA1140GCBK21IMR
C110PA1160GCBK21IMR
C110PA1190GCBK21IMR
C110PA1240GCBK21IMF
C110PA1300GCBK21IMF
C110PA1370GCBK21IMF
C112PA1070GCBK21IMR
C112PA1100GCBK21IMR
C112PA1120GCBK21IMR
C112PA1140GCBK21IMR
C112PA1160GCBK21IMR
C112PA1190GCBK21IMR
C112PA1240GCBK21IMF
C112PA1300GCBK21IMF
C112PA1370GCBK21IMF
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations, for connecting signaling and control units in industries, railways,
trafc signals, power stations, industrial plants and switchgears if mechanical protection is
required, or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
47
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
Current Rating
Laid in
ground
A
18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5
Laid in
ducts
A
1.5 mm
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0
15.3
17.0
19.3
19.8
21.0
21.9
22.5
25.7
27.3
28.9
350
430
570
625
690
800
850
1030
1185
1400
Laid in
free air
AES Code
C208PA1050GCBK12IMR
C208PA1070GCBK21IMR
C208PA1100GCBK21IMR
C208PA1120GCBK21IMR
C208PA1140GCBK21IMR
C208PA1160GCBK21IMR
C208PA1190GCBK21IMR
C208PA1240GCBK21IMF
C208PA1300GCBK21IMF
C208PA1370GCBK21IMF
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
2
0.6 / 1 kV
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
Current Rating
Laid in
ground
A
24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0
31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0
Laid in
ducts
A
2.5 mm
20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0
4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5
16.2
17.3
20.9
21.5
22.4
23.4
24.5
28.1
30.3
31.9
440
530
710
790
880
970
1090
1340
1630
1875
C210PA1050GCBK12IMR
24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0
19.1
20.4
24.9
25.6
26.7
28.0
29.4
34.4
36.5
39.4
660
740
960
1120
1270
1390
1610
2030
2660
3250
C212PA1050GCBK12IMR
Laid in
free air
AES Code
C210PA1070GCBK21IMR
C210PA1100GCBK21IMR
C210PA1120GCBK21IMR
C210PA1140GCBK21IMR
C210PA1160GCBK21IMR
C210PA1190GCBK21IMR
C210PA1240GCBK21IMF
C210PA1300GCBK21IMF
C210PA1370GCBK21IMF
C212PA1070GCBK21IMR
C212PA1100GCBK21IMR
C212PA1120GCBK21IMR
C212PA1140GCBK21IMR
C212PA1160GCBK21IMR
C212PA1190GCBK21IMR
C212PA1240GCBK21IMF
C212PA1300GCBK21IMF
C212PA1370GCBK21IMF
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations, for connecting signaling and control units in industries, railways,
trafc signals, power stations, industrial plants and switchgears if mechanical protection is
required, or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
49
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
Current Rating
Laid in
ground
A
18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5
Laid in
ducts
A
1.5 mm
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0
16.0
17.2
20.2
22.5
23.3
24.2
25.2
28.0
30.1
33.0
470
530
740
1050
1110
1220
1320
1530
1800
2180
Laid in
free air
AES Code
C108PA1050WCBK12IMR
C108PA1070WCBK21IMR
C108PA1100WCBK21IMR
C108PA1120WCBK21IMR
C108PA1140WCBK21IMR
C108PA1160WCBK21IMR
C108PA1190WCBK21IMR
C108PA1240WCBK21IMF
C108PA1300WCBK21IMF
C108PA1370WCBK21IMF
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
2
0.6 / 1 kV
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
Current Rating
Laid in
ground
A
24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0
31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0
Laid in
ducts
A
2.5 mm
20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0
4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5
17.2
18.4
22.9
24.2
25.1
26.1
27.4
30.5
33.7
36.6
570
640
1125
1240
1350
1470
1620
1970
2380
2790
C110PA1050WCBK12IMR
24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0
20.2
22.7
26.3
28.2
29.2
30.8
32.1
37.5
40.4
43.3
750
1150
1460
1650
1790
1980
2150
3010
3430
4020
C112PA1050WCBK12IMR
Laid in
free air
AES Code
C110PA1070WCBK21IMR
C110PA1100WCBK21IMR
C110PA1120WCBK21IMR
C110PA1140WCBK21IMR
C110PA1160WCBK21IMR
C110PA1190WCBK21IMR
C110PA1240WCBK21IMF
C110PA1300WCBK21IMF
C110PA1370WCBK21IMF
C112PA1070WCBK21IMR
C112PA1100WCBK21IMR
C112PA1120WCBK21IMR
C112PA1140WCBK21IMR
C112PA1160WCBK21IMR
C112PA1190WCBK21IMR
C112PA1240WCBK21IMF
C112PA1300WCBK21IMF
C112PA1370WCBK21IMF
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations, for connecting signaling and control units in industries, railways,
trafc signals, power stations, industrial plants and switchgears if mechanical protection is
required, or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
51
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
No. X mm2
/ km
/ km
5 X 1.5
7 X 1.5
10 X 1.5
12 X 1.5
14 X 1.5
16 X 1.5
19 X 1.5
24 X 1.5
30 X 1.5
37 X 1.5
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
12.1000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
14.6000
Current Rating
Laid in
ground
A
18.0
16.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.5
Laid in
ducts
A
1.5 mm2
15.5
14.0
12.5
11.5
10.5
10.0
9.0
8.0
7.5
6.5
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
13.5
12.5
11.5
10.5
9.5
9.0
8.0
7.5
6.5
6.0
16.6
18.0
21.0
23.3
24.2
25.0
26.0
28.9
31.0
34.0
500
550
770
1080
1140
1260
1370
1620
1850
2250
Laid in
free air
AES Code
C208PA1050WCBK12IMR
C208PA1070WCBK21IMR
C208PA1100WCBK21IMR
C208PA1120WCBK21IMR
C208PA1140WCBK21IMR
C208PA1160WCBK21IMR
C208PA1190WCBK21IMR
C208PA1240WCBK21IMF
C208PA1300WCBK21IMF
C208PA1370WCBK21IMF
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
5 X 2.5
7 X 2.5
10 X 2.5
12 X 2.5
14 X 2.5
16 X 2.5
19 X 2.5
24 X 2.5
30 X 2.5
37 X 2.5
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
7.4100
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
8.8700
5 X 4.0
7 X 4.0
10 X 4.0
12 X 4.0
14 X 4.0
16 X 4.0
19 X 4.0
24 X 4.0
30 X 4.0
37 X 4.0
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
2
0.6 / 1 kV
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
4.6100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
5.5100
Current Rating
Laid in
ground
A
24.0
22.0
20.0
18.0
16.0
15.0
14.0
13.0
11.5
10.0
31.0
28.0
25.0
23.0
20.5
19.5
18.0
16.0
14.5
13.0
Laid in
ducts
A
2.5 mm
20.5
18.5
16.5
15.5
14.0
13.0
12.0
11.0
10.0
9.0
4.0 mm2
25.5
23.0
21.0
19.5
17.0
16.0
15.0
13.5
12.0
11.0
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
18.0
16.0
14.5
13.5
12.0
11.0
10.5
9.5
8.5
7.5
17.8
19.2
23.8
25.0
26.0
27.0
28.3
31.4
34.5
37.4
600
660
960
1280
1390
1510
1670
2030
2450
2870
C210PA1050WCBK12IMR
24.0
21.5
19.5
18.0
16.0
15.0
14.0
12.5
11.0
10.0
20.8
23.5
27.2
29.0
30.0
31.6
33.0
38.4
41.3
44.5
780
1190
1510
1700
1850
2040
2260
3070
3560
4120
C212PA1050WCBK12IMR
Laid in
free air
AES Code
C210PA1070WCBK21IMR
C210PA1100WCBK21IMR
C210PA1120WCBK21IMR
C210PA1140WCBK21IMR
C210PA1160WCBK21IMR
C210PA1190WCBK21IMR
C210PA1240WCBK21IMF
C210PA1300WCBK21IMF
C210PA1370WCBK21IMF
C212PA1070WCBK21IMR
C212PA1100WCBK21IMR
C212PA1120WCBK21IMR
C212PA1140WCBK21IMR
C212PA1160WCBK21IMR
C212PA1190WCBK21IMR
C212PA1240WCBK21IMF
C212PA1300WCBK21IMF
C212PA1370WCBK21IMF
Power Cables
To BS Standard
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
53
4
6
10
16
25
35
rm
rm
rm
rm
rm
rm
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
4
6
10
16
25
35
rm
rm
rm
rm
rm
sm
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
39
50
66
88
116
143
15.1
16.3
19.2
21.2
25.7
27.9
470
560
815
1035
1595
1910
C212PA1020WCBK01BMR
15.8
17.8
20.6
22.8
27.5
26.9
535
735
910
1160
1785
2000
C212PA1030WCBK04BMR
Laid in
free air
32
40
55
65
85
105
30
36
48
60
80
100
31
39
53
72
94
110
AES Code
C213PA1020WCBK01BMR
C314PA1020WCBK01BMR
C315PA1020WCBK01BMR
C316PA1020WCBK01BMR
C317PA1020WCBK01BMR
C213PA1030WCBK04BMR
C314PA1030WCBK04BMR
C315PA1030WCBK04BMR
C316PA1030WCBK04BMR
C417PA1030WCBK04BMR
600 / 1000 V
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
5.5400
3.6900
2.1900
1.3900
0.8700
0.6280
0.4640
0.3220
0.2320
0.1850
0.1510
0.1210
0.0840
0.0770
4
6
10
16
25
35
50
70
95
120
150
185
240
300
rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
Current Rating
Laid in
ground
A
Laid in
ducts
A
29
37
50
68
89
95
115
145
165
195
220
245
290
320
Approx.
overall
weight
mm
Kg / km
29
37
50
68
89
116
143
176
215
248
281
319
380
446
17.8
19.0
22.1
25.8
29.9
30.4
35.3
38.9
42.6
47.6
52.1
57.3
63.6
69.7
720
850
1085
1585
2165
2515
3545
4515
5757
Laid in
free air
Approx.
overall
diameter
7430
8755
10710
13380
16176
AES Code
C212PA1040WCBK08BMR
C213PA1040WCBK08BMR
C314PA1040WCBK08BMR
C315PA1040WCBK08BMR
C316PA1040WCBK08BMR
C417PA1040WCBK08BMR
C418PA1040WCBK08BMR
C419PA1040WCBK08BMR
C445PA1040WCBK08BMF
C446PA1040WCBK08BMF
C447PA1040WCBK08BMF
C448PA1040WCBK08BMS
C449PA1040WCBK08BMS
C450PA1040WCBK08BMS
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
16
25
35
rm
rm
rm
1.9100
1.2000
0.8680
2.2900
1.4400
1.0430
16
25
35
rm
rm
sm
1.9100
1.2000
0.8680
2.2900
1.4400
1.0430
Current Rating
Laid in
ground
A
Laid in
ducts
A
46
60
83
Approx.
overall
weight
mm
Kg / km
62
81
115
21.2
25.7
27.9
845
1285
1485
A315PA1020WCBK01BMR
22.8
27.5
26.9
875
1325
1380
A315PA1030WCBK04BMR
Laid in
free air
Approx.
overall
diameter
AES Code
A316PA1020WCBK01BMR
A317PA1020WCBK01BMR
55
53
70
95
42
56
75
50
66
88
A316PA1030WCBK04BMR
A417PA1030WCBK04BMR
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
mm
/ km
/ km
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
2.2900
1.4400
1.0430
0.7710
0.5330
0.3850
0.3050
0.2490
0.1990
0.1510
0.1230
16
25
35
50
70
95
120
150
185
240
300
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
Current Rating
Laid in
ground
A
Laid in
ducts
A
42
56
75
85
110
130
150
170
195
225
260
Approx.
overall
weight
mm
Kg / km
50
66
88
105
138
165
193
220
253
297
352
25.8
29.9
30.4
35.3
38.9
42.6
47.6
52.1
57.3
63.6
69.7
1205
1550
1695
2405
2915
3490
4530
5255
6170
7450
8815
Laid in
free air
Approx.
overall
diameter
AES Code
A315PA1040WCBK08BMR
A316PA1040WCBK08BMR
A417PA1040WCBK08BMR
A418PA1040WCBK08BMR
A419PA1040WCBK08BMR
A445PA1040WCBK08BMR
A446PA1040WCBK08BMF
A447PA1040WCBK08BMF
A448PA1040WCBK08BMF
A449PA1040WCBK08BMS
A450PA1040WCBK08BMS
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is not
exposed to mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
57
Nominal
cross
sectional
area
mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000
600 / 1000 V
DIMENSIONS AND
WEIGHTS
ELECTRICAL DATA
Current Rating
Laid in ground
Laid in free air
Max. Conductor
Resistance
DC at
20 C
/ km
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176
AC at
90 C
/ km
0.4940
0.3430
0.2480
0.1970
0.1600
0.1290
0.0990
0.0810
0.0638
0.0517
0.0425
0.0292
0.0234
210
263
310
357
394
452
520
588
672
761
872
957
1082
200
247
294
336
373
425
488
546
620
693
777
861
935
163
200
242
273
310
352
404
457
515
572
651
735
798
221
278
347
404
457
530
651
824
893
1008
1155
1313
1449
210
268
336
394
446
520
641
756
872
987
1134
1292
1428
184
236
289
341
389
441
536
620
714
814
956
1092
1208
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
12.9
14.7
16.5
18.0
20.1
22.2
24.9
27.7
30.9
34.9
39.3
43.8
51.5
530
730
980
1225
1490
1870
2420
3020
3855
4985
6290
8090
10075
AES Code
C318XA10100MBK51BMR
C319XA10100MBK51BMR
C345XA10100MBK51BMR
C346XA10100MBK51BMR
C347XA10100MBK51BMR
C348XA10100MBK51BMR
C349XA10100MBK51BMR
C350XA10100MBK51BMR
C351XA10100MBK51BMF
C352XA10100MBK51BMF
C353XA10100MBK51BMF
C354XA10100MBK51BMF
C355XA10100MBK51BMF
CONSTRUCTION
Conductor
Insulation
Outer sheath :
APPLICATION
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants
and switchgears if mechanical protection is not required, or in applications where the cable is not
exposed to mechanical damage.
TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
59
Nominal
cross
sectional
area
mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000
600 / 1000 V
DIMENSIONS AND
WEIGHTS
ELECTRICAL DATA
Current Rating
Laid in ground
Laid in free air
Max. Conductor
Resistance
DC at
20 C
/ km
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
0.0778
0.0605
0.0469
0.0367
0.0291
AC at
90 C
/ km
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310
0.1000
0.0870
0.0620
0.0560
0.0470
163
200
236
278
310
352
410
467
541
609
698
788
872
155
189
226
263
294
336
389
436
504
567
646
704
767
121
152
179
215
236
267
315
357
410
467
536
599
651
173
221
284
326
373
436
515
578
693
809
945
1071
1176
168
215
273
315
362
420
499
567
677
788
924
1050
1155
147
179
215
242
299
336
399
462
541
630
746
851
966
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
12.9
14.7
16.5
18.0
20.1
22.2
24.9
27.7
30.9
34.9
39.3
43.8
51.5
235
310
405
495
605
740
945
1160
1465
1855
2355
2990
3870
AES Code
A318XA10100MBK51BMR
A319XA10100MBK51BMR
A345XA10100MBK51BMR
A346XA10100MBK51BMR
A347XA10100MBK51BMR
A348XA10100MBK51BMR
A349XA10100MBK51BMR
A350XA10100MBK51BMR
A351XA10100MBK51BMR
A352XA10100MBK51BMF
A353XA10100MBK51BMF
A354XA10100MBK51BMF
A355XA10100MBK51BMF
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm2
/ km
/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
5.8800
3.9300
2.3300
1.4700
0.9270
0.6690
4
6
10
16
25
35
4
6
10
16
25
35
61
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
rm
sm
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
5.8800
3.9300
2.3300
1.4700
0.9270
0.6690
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
47
61
80
106
140
168
14.7
15.7
17.1
19.8
23.2
26.5
445
520
640
930
1290
1770
C212XA1020WMBK01BMR
15.3
16.4
19.1
21.5
26.2
25.7
500
595
815
1065
1665
1865
C212XA1030WMBK04BMR
Laid in
free air
41
53
70
84
108
135
37
46
61
76
103
122
42
51
69
90
120
147
AES Code
C213XA1020WMBK01BMR
C314XA1020WMBK01BMR
C315XA1020WMBK01BMR
C316XA1020WMBK01BMR
C317XA1020WMBK01BMR
C213XA1030WMBK04BMR
C314XA1030WMBK04BMR
C315XA1030WMBK04BMR
C316XA1030WMBK04BMR
C417XA1030WMBK04BMR
600 / 1000 V
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm
/ km
/ km
4.6100
3.0800
1.8300
1.1500
0.7270
0.5240
0.3870
0.2680
0.1930
0.1530
0.1240
0.0991
0.0754
0.0601
5.8800
3.9300
2.3300
1.4700
0.9270
0.6690
0.4940
0.3430
0.2480
0.1970
0.1600
0.1290
0.0990
0.0810
4
6
10
16
25
35
50
70
95
120
150
185
240
300
rm
rm
rm
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
Current Rating
Laid in
ground
A
Laid in
ducts
A
37
46
61
76
103
122
145
180
210
245
275
310
365
405
Approx.
overall
weight
mm
Kg / km
42
51
69
90
122
147
184
220
273
315
375
410
488
562
16.4
18.5
20.4
23.1
28.2
28.7
32.4
37.4
40.1
45.4
49.9
54.9
60.9
66.5
575
795
960
1280
1990
2335
2975
4270
5375
6980
8280
10103
12660
15305
Laid in
free air
Approx.
overall
diameter
AES Code
C212XA1040WMBK08BMR
C213XA1040WMBK08BMR
C314XA1040WMBK08BMR
C315XA1040WMBK08BMR
C316XA1040WMBK08BMR
C417XA1040WMBK08BMR
C418XA1040WMBK08BMR
C419XA1040WMBK08BMR
C445XA1040WMBK08BMF
C446XA1040WMBK08BMF
C447XA1040WMBK08BMF
C448XA1040WMBK08BMS
C449XA1040WMBK08BMS
C450XA1040WMBK08BMS
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations in power stations, industrial plants and switchgears if mechanical
protection is required or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 90 C
- Max. admissible temperature of conductor at short circuit 250 C for 5 seconds
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm2
/ km
/ km
1.9100
1.2000
0.8680
2.4500
1.5400
1.1130
16
25
35
rm
rm
rm
Current Rating
Laid in
ground
A
Laid in
ducts
A
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
79
101
131
19.8
23.2
26.5
740
980
1340
A315XA1020WMBK01BMR
21.5
26.2
25.7
780
1205
1245
A315XA1030WMBK04BMR
Laid in
free air
57
74
105
AES Code
A316XA1020WMBK01BMR
A317XA1020WMBK01BMR
63
rm
rm
sm
1.9100
1.2000
0.8680
2.4500
1.5400
1.1130
67
89
120
52
70
95
67
89
115
A316XA1030WMBK04BMR
A417XA1030WMBK04BMR
600 / 1000 V
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Nominal
cross
sectional
area
DC at 20 C
AC at 90 C
mm
/ km
/ km
1.9100
1.2000
0.8680
0.6410
0.4430
0.3200
0.2530
0.2060
0.1640
0.1250
0.1000
2.4500
1.5400
1.1130
0.8220
0.5690
0.4110
0.3250
0.2650
0.2120
0.1630
0.1310
16
25
35
50
70
95
120
150
185
240
300
rm
rm
sm
sm
sm
sm
sm
sm
sm
sm
sm
Current Rating
Laid in
ground
A
Laid in
ducts
A
52
70
95
110
140
165
190
215
240
280
315
Approx.
overall
weight
mm
Kg / km
67
89
115
141
173
210
241
283
320
383
451
23.1
28.2
28.7
32.4
37.4
40.1
45.4
49.9
54.9
60.9
66.5
900
1370
1510
1835
2665
3095
4070
4775
5550
6720
7925
Laid in
free air
Approx.
overall
diameter
AES Code
A315XA1040WMBK08BMR
A316XA1040WMBK08BMR
A417XA1040WMBK08BMR
A418XA1040WMBK08BMR
A419XA1040WMBK08BMR
A445XA1040WMBK08BMR
A446XA1040WMBK08BMF
A447XA1040WMBK08BMF
A448XA1040WMBK08BMF
A449XA1040WMBK08BMS
A450XA1040WMBK08BMS
Control Cables
To BS Standard
CONSTRUCTION
Conductor
Insulation
Bedding
Armouring
Outer sheath :
APPLICATION
For outdoor installations, for connecting signaling and control units in industries, railways,
trafc signals, power stations, industrial plants and switchgears if mechanical protection is
required, or in applications where mechanical damages are expected to occur.
TECHNICAL DATA
- Nominal voltage Uo/U = 600 / 1000 V
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70 C
- Max. admissible temperature of conductor at short circuit 160 C for 5 seconds
65
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
DC at 20 C
AC at 70 C
No. X mm2
/ km
/ km
7 X 1.5
12 X 1.5
19 X 1.5
27 X 1.5
37 X 1.5
12.1000
12.1000
12.1000
12.1000
12.1000
14.6000
14.6000
14.6000
14.6000
14.6000
Current Rating
Laid in
ground
A
16.0
13.0
10.0
8.0
7.5
Laid in
ducts
A
1.5 mm2
14.0
11.5
9.0
7.5
6.5
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
12.5
10.5
8.0
6.5
6.0
15.6
19.7
22.6
27.1
30.0
490
790
1040
1515
1860
Laid in
free air
AES Code
C208PA1070WCBK21BMR
C208PA1120WCBK21BMR
C208PA1190WCBK21BMR
C208PA1270WCBK21BMF
C208PA1370WCBK21BMF
DC at 20 C
AC at 70 C
No. X mm
/ km
/ km
7 X 2.5
12 X 2.5
7.4100
7.4100
8.8700
8.8700
19 X 2.5
27 X 2.5
37 X 2.5
DIMENSIONS
AND WEIGHTS
ELECTRICAL DATA
Number &
Nominal
cross
sectional
area
2
600 / 1000 V
7.4100
7.4100
7.4100
8.8700
8.8700
8.8700
Current Rating
Laid in
ground
A
22.0
18.0
14.0
11.5
10.0
Laid in
ducts
A
2.5 mm
18.5
15.5
12.0
10.0
9.0
Approx.
overall
diameter
Approx.
overall
weight
mm
Kg / km
16.0
13.5
18.3
22.4
725
1025
Laid in
free air
10.5
8.5
7.5
26.9
31.0
34.4
1575
2020
2495
AES Code
C210PA1070WCBK21BMR
C210PA1120WCBK21BMR
C210PA1190WCBK21BMR
C210PA1270WCBK21BMF
C210PA1370WCBK21BMF
4.0 mm
7 X 4.0
12 X 4.0
19 X 4.0
27 X 4.0
37 X 4.0
4.6100
4.6100
4.6100
4.6100
4.6100
5.5100
5.5100
5.5100
5.5100
5.5100
28.0
23.0
18.0
14.5
13.0
23.0
19.5
15.0
12.0
11.0
21.5
18.0
14.0
11.0
10.0
20.9
27.1
31.1
37.1
41.1
940
1570
2115
3110
3840
C212PA1070WCBK21BMR
C212PA1120WCBK21BMR
C212PA1190WCBK21BMR
C212PA1270WCBK21BMF
C212PA1370WCBK21BMF
Cables For
Special Applications
Application
For outdoor installations in damp and wet locations in chemical
and petrol plants in which mechanical protection is required or in
applications where mechanical damages are expected to occur.
Main properties
Radially watertight
Corrosion resistant
Where necessary, it is available with the longitudinal
watertight protection
Suitable for use in hostile environment or underground
Especially suitable for submarine installation
Resistant to aggressive chemical substances
Offer good protection against rodents
Application
Low smoke halogen free power cables with enhanced characteristics
in case of re are used for applications where harm to human life
and damage to property must be prevented in the event of re,
e.g. in industrial installations, commercial establishments,
hotels, airports, underground stations, railway stations, hospitals,
banks, schools, etc.
Main properties
Reduced smoke and toxic gases emission in the event of re
Reduced acid gases emission in the event of re
Excellent ame retardant properties
67
Other possibilities:
Delivery lengths other than standard lengths
Products as per other national and international norms/standards
Technical Data
Recommendations
Installation of Cables
A. Minimum installation radius
None of the low voltage power or control cables should be bent
during installation to a radius smaller than the following:
Tm = 0.036
Tm = 0.027
69
X
X
n
n
X
X
Cm (Copper)
Cm (Aluminum)
Where
Tm : Maximum pulling tension in N
n : The number of conductors
Cm : Circular mil area of each conductor
The maximum limitation for this calculation is 22240 N for single conductor (1/C) cables, and 44480 N for multi-core
cables. This limitation is due to unequal distribution of tension forces when pulling multiple conductors.
When the calculated pulling tension is close to (or within 10% of) the maximum pulling tension, the use of a tension
gauge during the pulling is recommended.
D.2 Cable grip over lead sheath
With cable grip over lead sheath, with commercial lead, the maximum pulling tension on the lead sheath should not
exceed 10.33 N/mm2.
D.3 Cable grip over non-leaded cable
With cable grip over non-leaded cable, the maximum pulling tension should not exceed 4400 N.
E. Sidewall pressure
One of the limitations to be considered for the installation of electrical cables is sidewall pressure. The sidewall
pressure is the force exerted on the insulation and sheath of the cable at a bend point when the cable is under
tension, and is normally the limiting factor in an installation where cable bends are involved. The sidewall
pressure in general is expressed as the tension out of a bend expressed in newtons divided by the inside radius of the
bend expressed in meters.
P=
To
r
Where
P : Sidewall pressure in N/m
To : Tension leaving the bend in N
r : Inside radius of conduit in m
The normal maximum sidewall pressure per meter of radius is as given below. However, in order to minimize cable
damage due to excessive sidewall pressure, the installer should check the proper recommendations for each
type of cables to be installed.
Cable type
7300
Armoured cables
4400
7300
Formulas
71
Material Properties
Metals Used For Cables
Table 1
ELECTRICAL PROPERTIES
Metal
Relative Conductivity
Copper 100
Electrical Resistivity at
20 C .m ( 10-8 )
Temperature Coefcient
of Resistance per C
100
97
95 97
61
8
1.7241
1.7770
1.741 1.814
2.8264
21.40
0.00393
0.00393
0.00393
0.00403
0.00400
Copper (Annealed)
Copper (Hard drawn)
Tinned Copper
Aluminum
Lead
PHYSICAL PROPERTIES
Property
Unit
Copper
Kg/m3
C x 10-6
C
W/Cm.C
Density at 20 C
Coeff. of thermal expansion
Melting point
Thermal conductivity
Aluminum
8890.0
17.0
1083.0
3.8
2703.0
23.0
659.0
2.4
Lead
11340.0
29.0
327.0
0.34
PVC
Nominal
Emergency
Short Circuit
90
130
250
Mechanical
Strength
12.5
200
12.5
150
4.2
200
Good
2.5
0.93
Good
Poor
8.0
1.5
Poor
10
10
10
Excellent
3.0
1.4
Poor
Easy
Good
Easy
Good
Easy
Poor
.cm
12
70
95
140 * or 160 **
EPR
Rated Temp.
73
XLPE
90
130
250
12
10
Derating Factors
Table 3
temperature
C
25
30
35
40
45
50
55
70 C
1.13
1.07
1.00
0.93
0.85
0.76
0.65
90 C
1.09
1.04
1.00
0.95
0.90
0.85
0.80
Table 4
temperature
C
25
30
35
40
45
50
55
70 C
1.22
1.15
1.08
1.00
0.95
0.82
0.71
1.14
1.10
1.05
1.00
0.95
0.89
0.84
90 C
Table 5
95 up to 240 mm2
1.00
0.60
0.99
0.98
0.97
0.80
0.97
0.96
0.94
1.00
0.95
0.93
0.92
1.25
0.94
0.92
0.89
1.50
0.93
0.90
0.87
1.75
0.92
0.89
0.86
2.00
0.91
0.88
0.85
Derating Factors
Table 6
0.8
0.9
1.0
1.2
1.5
2.0
2.5
1.17
1.12
1.07
1.00
0.91
0.80
0.73
Table 7
70
85
95
105
1.000
1.195
1.309
1.414
Table 8
Number
Spacing
Spacing
Spacing
of
Trefoil formation
circuits
75
Touching
Flat formation
Spacing = 0.15 Mt.
Trefoil
Flat
Trefoil
Flat
Trefoil
Flat
0.77
0.80
0.82
0.85
0.88
0.91
0.66
0.69
0.73
0.76
0.80
0.83
0.60
0.63
0.68
0.71
0.74
0.77
0.56
0.59
0.64
0.67
0.72
0.75
0.53
0.57
0.61
0.64
0.70
0.73
Table 9
Number of circuits
1
0.92
0.89
0.88
0.92
0.89
0.88
0.87
0.84
0.83
Number of troughs
0.84
0.82
0.81
0.82
0.80
0.79
Number of circuits
1
1.00
0.97
0.96
0.97
0.94
0.93
0.96
0.93
0.92
0.94
0.91
0.90
Rating factor
0.94
0.91
0.89
Number of circuits
1
0.89
0.86
0.84
Derating Factors
Table 10
Number of circuits
1
0.95
0.90
0.88
Number of troughs
0.95
0.90
0.88
0.90
0.85
0.83
0.88
0.83
0.81
0.86
0.81
0.79
Number of circuits
1
1.00
0.98
0.96
1.00
0.95
0.93
1.00
0.94
0.92
1.00
0.93
0.90
77
Number of circuits
1
1.00
1.00
1.00
Table 11
Number of circuits
1
0.95
0.90
0.88
0.85
0.84
Number of circuits
1
0.95
0.90
0.88
0.85
0.84
Number of troughs
2
0.90
0.85
0.83
0.81
0.80
0.88
0.83
0.81
0.79
0.78
0.86
0.81
0.79
0.77
0.76
Number of circuits
1
Number of racks
1.00
0.98
0.96
0.93
0.92
1.00
0.95
0.93
0.90
0.89
1.00
0.94
0.92
0.89
0.88
1.00
0.93
0.90
0.87
0.86
Rating factor
1.00
0.93
0.90
0.87
0.86
Rating factor
1.00
1.00
1.00
1.00
1.00
Derating Factors
Table 12
Rating factor
0.90
0.84
0.80
0.75
0.73
Number of circuits
1
0.95
0.84
0.80
0.75
0.73
0.95
0.80
0.76
0.71
0.69
0.95
0.78
0.74
0.70
0.68
0.95
0.76
0.72
0.68
0.66
Number of troughs
Number of circuits
1
0.95
0.84
0.80
0.75
0.73
0.95
0.80
0.76
0.71
0.69
0.95
0.78
0.74
0.70
0.68
0.95
0.76
0.72
0.68
0.66
Number of racks
79
Number of circuits
Rating factor
0.95
0.78
0.73
0.68
0.66
Cable component
Insulation
PVC Insulation
Sheathing
2
2
XLPE Insulation
250
PVC Sheath
200
LDPE Sheath
150
HDPE Sheath
180
Lead Sheath
170
200
Table 14
mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
0.55
0.91
1.45
2.18
3.6
5.8
9.1
12.7
18.2
25.5
34.5
43.6
54.5
67.3
87.3
109.1
130.0
162.5
204.8
260.1
325.1
0.2
0.39
0.64
1.03
1.54
2.6
4.1
6.4
9.0
12.9
18.0
24.4
30.9
38.6
47.6
61.7
77.1
91.9
114.9
144.8
183.9
229.9
0.3
0.31
0.52
0.84
1.26
2.1
3.4
5.2
7.3
10.5
14.7
19.9
25.2
31.5
38.8
50.4
63.0
75.1
93.8
118.2
150.1
187.7
0.4
0.27
0.45
0.73
1.09
1.8
2.9
4.5
6.4
9.1
12.7
17.3
21.8
27.3
33.6
43.6
54.5
65.0
81.3
102.4
130.0
162.5
0.5
0.24
0.41
0.65
0.98
1.6
2.6
4.1
5.7
8.1
11.4
15.5
19.5
24.4
30.1
39.0
48.8
58.2
72.7
91.6
116.3
145.4
1.0
0.17
0.29
0.46
0.69
1.2
1.8
2.9
4.0
5.8
8.1
10.9
13.8
17.3
21.3
27.6
34.5
41.1
51.4
64.8
82.2
102.8
2.0
0.12
0.20
0.33
0.49
0.8
1.3
2.0
2.8
4.1
5.7
7.7
9.8
12.2
15.0
19.5
24.4
29.1
36.3
45.8
58.2
72.7
3.0
0.10
0.17
0.27
0.40
0.7
1.1
1.7
2.3
3.3
4.6
6.3
8.0
10.0
12.3
15.9
19.9
23.7
29.7
37.4
47.5
59.4
4.0
0.09
0.14
0.23
0.35
0.6
0.9
1.4
2.0
2.9
4.0
5.5
6.9
8.6
10.6
13.8
17.3
20.6
25.7
32.4
41.1
51.4
5.0
0.08
0.13
0.21
0.31
0.5
0.8
1.3
1.8
2.6
3.6
4.9
6.2
7.7
9.5
12.3
15.4
18.4
23.0
29.0
36.8
46.0
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
3.8
6.0
8.4
12.0
16.8
22.8
28.8
36.0
44.5
57.7
72.1
86.0
107.5
135.5
172.0
215.0
0.2
2.7
4.2
5.9
8.5
11.9
16.1
20.4
25.5
31.4
40.8
51.0
60.8
76.0
95.8
121.6
152.1
0.3
2.2
3.5
4.9
6.9
9.7
13.2
16.7
20.8
25.7
33.3
41.6
49.7
62.1
78.2
99.3
124.2
0.4
1.9
3.0
4.2
6.0
8.4
11.4
14.4
18.0
22.2
28.8
36.0
43.0
53.8
67.7
86.0
107.5
0.5
1.7
2.7
3.8
5.4
7.5
10.2
12.9
16.1
19.9
25.8
32.2
38.5
48.1
60.6
76.9
96.2
1.0
1.2
1.9
2.7
3.8
5.3
7.2
9.1
11.4
14.1
18.2
22.8
27.2
34.0
42.8
54.4
68.0
2.0
0.9
1.3
1.9
2.7
3.8
5.1
6.4
8.1
9.9
12.9
16.1
19.2
24.0
30.3
38.5
48.1
3.0
0.7
1.1
1.5
2.2
3.1
4.2
5.3
6.6
8.1
10.5
13.2
15.7
19.6
24.7
31.4
39.3
4.0
0.6
1.0
1.3
1.9
2.7
3.6
4.6
5.7
7.0
9.1
11.4
13.6
17.0
21.4
27.2
34.0
5.0
0.5
0.8
1.2
1.7
2.4
3.2
4.1
5.1
6.3
8.2
10.2
12.2
15.2
19.2
24.3
30.4
Table 16
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
81
4.7
7.4
10.4
14.8
20.7
28.1
35.6
44.4
54.8
71.1
88.9
118.5
148.2
186.7
237.0
296.3
0.2
3.4
5.2
7.3
10.5
14.7
19.9
25.1
31.4
38.8
50.3
62.9
83.8
104.8
132.0
167.6
209.5
0.3
2.7
4.3
6.0
8.6
12.0
16.3
20.5
25.7
31.6
41.1
51.3
68.4
85.5
107.8
136.9
171.1
0.4
2.4
3.7
5.2
7.4
10.4
14.1
17.8
22.2
27.4
35.6
44.4
59.3
74.1
93.3
118.5
148.2
0.5
2.1
3.3
4.6
6.6
9.3
12.6
15.9
19.9
24.5
31.8
39.8
53.0
66.3
83.5
106.0
132.5
1.0
1.5
2.3
3.3
4.7
6.6
8.9
11.2
14.1
17.3
22.5
28.1
37.5
46.9
59.0
75.0
93.7
2.0
1.1
1.7
2.3
3.3
4.6
6.3
8.0
9.9
12.3
15.9
19.9
26.5
33.1
41.7
53.0
66.3
3.0
0.9
1.4
1.9
2.7
3.8
5.1
6.5
8.1
10.0
13.0
16.2
21.6
27.0
34.1
43.3
54.1
4.0
0.75
1.2
1.6
2.3
3.3
4.5
5.6
7.0
8.7
11.2
14.1
18.7
23.4
29.5
37.5
46.9
5.0
0.67
1.0
1.5
2.1
2.9
4.0
5.0
6.3
7.8
10.1
12.6
16.8
21.0
26.4
33.5
41.9
Table 17
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
0.7
1.1
1.8
2.7
4.5
7.2
11.3
15.8
22.6
31.7
43.0
54.3
67.8
83.7
108.5
135.7
180.9
226.1
284.9
361.8
452.2
0.2
0.5
0.8
1.3
1.9
3.2
5.1
8.0
11.2
16.0
22.4
30.4
38.4
48.0
59.2
76.7
95.9
127.9
159.9
201.4
255.8
319.8
0.3
0.4
0.7
1.0
1.6
2.6
4.2
6.5
9.1
13.1
18.3
24.8
31.3
39.2
48.3
62.7
78.3
104.4
130.5
164.5
208.9
261.1
0.4
0.3
0.6
0.9
1.4
2.3
3.6
5.7
7.9
11.3
15.8
21.5
27.1
33.9
41.8
54.3
67.8
90.4
113.1
142.4
180.9
226.1
0.5
0.3
0.5
0.8
1.2
2.0
3.2
5.1
7.1
10.1
14.2
19.2
24.3
30.3
37.4
48.5
60.7
80.9
101.1
127.4
161.8
202.2
1.0
0.21
0.36
0.57
0.86
1.4
2.3
3.6
5.0
7.2
10.0
13.6
17.2
21.5
26.5
34.3
42.9
57.2
71.5
90.1
114.4
143.0
2.0
0.15
0.25
0.40
0.61
1.0
1.6
2.5
3.5
5.1
7.1
9.6
12.1
15.2
18.7
24.3
30.3
40.4
50.6
63.7
80.9
101.1
3.0
0.12
0.21
0.33
0.50
0.8
1.3
2.1
2.9
4.1
5.8
7.8
9.9
12.4
15.3
19.8
24.8
33.0
41.3
52.0
66.0
82.6
4.0
0.11
0.18
0.29
0.43
0.7
1.1
1.8
2.5
3.6
5.0
6.8
8.6
10.7
13.2
17.2
21.5
28.6
35.8
45.0
57.2
71.5
5.0
0.10
0.16
0.26
0.38
0.6
1.0
1.6
2.2
3.2
4.5
6.1
7.7
9.6
11.8
15.3
19.2
25.6
32.0
40.3
51.2
64.0
Voltage Drop
Table 18
C.S.A
mm 2
16
25
35
50
70
95
120
150
185
240
300
400
500
630
Copper Conductors
Voltage drop ( mV / Amp / Meter )
XLPE Insulated & PVC Sheathed
Trefoil
22.8
14.1
8.8
5.9
3.6
2.3
1.5
1.1
0.83
0.60
0.46
0.38
0.33
0.28
0.24
0.21
0.18
0.16
0.15
Aluminum Conductors
Voltage drop ( mV / Amp / Meter )
83
Flat
22.9
14.1
8.8
5.9
3.6
2.3
1.5
1.1
0.84
0.61
0.47
0.39
0.34
0.29
0.25
0.22
0.19
0.17
0.16
Trefoil
3.7
2.4
1.7
1.3
0.93
0.70
0.57
0.48
0.40
0.33
0.28
0.24
0.21
0.18
Table 19
C.S.A
2
mm
16
25
35
50
70
95
120
150
185
240
300
400
500
Copper Conductors
Voltage drop ( mV / Amp / Meter )
XLPE Insulated & PVC Sheathed
22.8
14.0
8.7
5.9
3.5
2.2
1.5
1.1
0.81
0.58
0.44
0.37
0.31
0.27
0.23
0.2
0.18
0.15
Aluminum Conductors
Voltage drop ( mV / Amp / Meter )
XLPE Insulated & PVC Sheathed
3.7
2.4
1.7
1.3
0.92
0.68
0.56
0.47
0.39
0.32
0.27
0.23
0.20
Coding Key
1
Copper
A:
Aluminum
2. Type of conductor
1:
2:
3:
4:
5:
6:
Solid
Stranded - Circular round
Stranded - Circular compacted
Stranded - Sector shaped
Flexible
Extra-flexible
85
1.5 mm2
2.5 mm2
4 mm2
6 mm2
10 mm2
16 mm2
25 mm2
35 mm2
50 mm2
70 mm2
3 x 10 + 6 mm2
3 x 16 + 10 mm2
3 x 25 + 16 mm2
3 x 35 + 16 mm2
3 x 50 + 25 mm2
3 x 70 + 35 mm2
3 x 95 + 50 mm2
3 x 120 + 70 mm2
3 x 150 + 70 mm2
3 x 185 + 95 mm2
3 x 240 + 120 mm2
3 x 300 + 150 mm2
3 x 400 + 185 mm2
95 mm2
10
11
12
13
14
15
16
17
18
19
46 :
120 mm2
X:
47 :
48 :
49 :
50 :
51 :
52 :
53 :
54 :
55 :
150 mm2
185 mm2
240 mm2
300 mm2
400 mm2
500 mm2
630 mm2
800 mm2
1000 mm2
R:
XLPE Insulation
PVC Insulation rated 70 C
PVC Insulation rated 85 C
6. Rated voltage
A:
0.6 / 1 kV
7. Cable construction
1:
2:
Cores
Pairs
1 Core
02 :
03 :
04 :
05 :
2 Cores
3 Cores
4 Cores
5 Cores
37 :
37 Cores
10. Shielding
N:
C:
Copper tape
Copper wires
0:
Without shielding
11. Armouring
0:
L:
N:
A:
B:
G:
W:
Without armouring
Pure lead sheathed
Lead alloy sheathed
Aluminum wire armoured
Aluminum tape armoured
Galvanized steel tape armoured
Galvanized steel wire armoured
T:
S:
D:
Black
RD :
GY :
GR :
YG :
GL :
Red
Grey
Green
Yellow / Green
Green / Yellow
1C - Red
01 :
04 :
08 :
12 :
21 :
2C - Red, Black
3C - Red, Yellow, Blue
4C - Red, Yellow, Blue, Black
5C - Red, Yellow, Blue, Black, G/Y
6C & Above - Black + No.
IEC Standard
BS Standard
Customer request
Wooden drum
Steel drum
250 Meter
500 Meter
1000 Meter
0.05 MVA at an operating voltage of 380V have to be transmitted by 4 cores cable with copper conductor, XLPE
insulated and PVC sheathed direct buried in the ground under the following laying conditions :
Burial depth
Soil thermal resistivity
Ambient ground temp.
Cable route length
:
:
:
:
0.5
1.2
35
50
m
K.m/W
C
m
Sx10 6
3 xU
0.05 x10 6
3 x380
= 76 A
Where
I : Load current in A
S : KVA rating
U : Line voltage in volts
According to the relevant current carrying capacity values for the used cable type, it has been found that the current
carrying capacity value for 4 X 16 mm2 cable under the required installation conditions is 97A, which is greater than the
required load current (76A). So, cable 4 X 16 mm2 can be used to carry the required load current.
Calculating cross-section according to voltage drop
The tabulated voltage drop values in this catalogue are based on a load power factor of 85% lagging and given for
a current one ampere for a one meter run. For any cable length, the values should be multiplied by the cable route length
in meters and by the load current in amperes.
The applicable formula to calculate the approximate voltage drop/ampere/meter is the following :
V ap =
V p x1000
IxL
mV/Amp/Meter
Where
Vap
I
L
Vp
:
:
:
:
By substituting current, cable route length, and maximum permissible voltage drop.
Vap =
9.5 x1000
= 2.5 mV/Amp/Meter
76 x50
To determine a suitable size of conductor, select a cable from the voltage drop tables, such that the selected voltage drop
value from the tables is less than the calculated value of 2.5 mv/amp/m. Also ensure that it will carry the desired
current. In this example, the nearest voltage drop value is 2.2 mv/amp/m, which is corresponding to size 16 mm2.
In situations where the load power factor is other than 85% lagging, the voltage drop equations shown in the
formula section should be used to calculate the voltage drop.
Weight-Imperial
v
v
Weight-Metric
Length-Metric
Miscellaneous-Imperial
Area-Imperial
Miscellaneous-Metric
Area-Metric
centimeters
Volume-Imperial
4.54609
Temperature
Lenght-Imperial
87
Volume-U.S.
Volume-Metric
Certicates
Product Range
manufactures a wide range of low, medium and high voltage electrical products under 50 categories.
Listed below is
s comprehensive product classication:
Load Center
METAL ENCLOSURES
Service Box Enclosures
Modular Enclosures
Extendable Cubicles
Telephone Box
Busbar Chamber w/o Main
METAL ACCESSORIES
Switch Boxes
Junction Boxes
89
Overhead conductors
Power Cables
Telephone Cables
LIGHTING
Halogen
Florescent
Energy Saving
COMMUNICATION SYSTEMS
Audio Intercom
Contact us
markets and sells over 800 electrical construction products in the Saudi Arabian markets and exports them to
several countries in the Middle East, Europe, Asia and Africa.
Through our several operational domains and a widespread network of distributors, we ensure uninterrupted supply of
products. We also provide solutions to our clients including end-users, project owners, engineering contractors
and consultants.
s highly-qualied engineers, sales & marketing teams not only cater to its customers requirements efciently,
they also manage prompt after-sales services and extend full technical support and consultancy services to them.
Toll-free No.
Email: info@alfanar.com
Website: www.alfanar.com
91