Vous êtes sur la page 1sur 14

ODU Alarm and Status

Indication

Category

Descriptions

Severity

TXPWR ALM

Alarm

The TX PWR is lower than 3 dB.

MJ

TX INPUT ALM

Alarm

The TX IF signal become out of range from

MJ

RXLEV ALM

Alarm

-29 dBm 5 dB.


The reception level become lower than -72dBm ~ -94dBm level.(It

MJ

depends on the modulation system and bit rates).


ODU CPU / Cable
Open

Alarm

CPU of ODU is faulty or IF CABLE between IDU - ODU of ODU is broken

MJ

or is not connected.
Indicates the control status of the ODU TX power output. When the TX

MUTE STATUS

Status

LO REF

Alarm

Loss of Ref LO signal of ODU.

MN

TX SW Status

Status

Radio interface TX SW usage state in 1+1 HS Redundant configuration

ODU ALM

Alarm

ODU TOTAL ALM


ATPC Power
Mode
ODU TYPE
MISMATCH

Alarm

Status
Alarm

power is set to Mute, Status is issued.

Indicates one of the TXPWR ALM, ODU PS ALM, APC ALM, TPC ALM,
ODU SELF CHECK ALM occurrence
Indicates one of the TXPWR ALM, TX INPUT ALM, RX Level ALM, ODU

CPU/CABLE OPEN ALM, LOREF, ODU ALM occurrence.


ATPC control signal fault (90sec) as well as MAX Power continuation
90sec
Indicate connected ODU type is not supported at iPASOLINK system, or
ODU type cannot use in provisioned modulation setting.

MJ
Highest
severity will
be displayed
MJ

ODU PS ALM

Alarm

ALM in a case of Power supply interruption to ODU.

MJ

ODUPS SET

Status

Status indication of the protection switch for ODU power supplies

STATUS

Modem Alarm and Status


Indication

Category

Descriptions

Severity

Unequipped (MODEM-A)

Alarm

Reserved and installed optional package is removed from optional slot.

MJ

Type Mismatch(MODEM-A)

Alarm

The equipped type of interface is different from configured type.

MJ

Communication FAIL(MODEM-A) Alarm

Communication failure of equipment internal control communication.

MJ

Module(MODEM-A)

Alarm

Equipment fault

MJ

BUS ERROR TX

Alarm

Data communication BUS failure condition in TX direction from STM-1 Card.

MJ

BUS ERROR RX

Alarm

Data communication BUS failure condition in RX direction from STM-1 Card.

MJ

RXSW STATUS

Status

Radio interface RX SW usage state in Redundant configuration

LOSS OF FRAME

Alarm

Loss of Frame at radio side.

MJ

FRAME ID

Alarm

Frame ID (route differentiation ID)

MJ

HIBER ALM

Alarm

Radio signal degradation (High BER threshold detection). (Threshold :1E-3/1E-4/1E-5)

MJ

LOBER ALM

Alarm

Radio signal degradation (Low BER threshold detection). (Threshold. :1E-6/1E-7/1E-8/1E-9)

MN

EARLY WARNING

Alarm

Radio signal degradation (Early Warning threshold detection). (Threshold :1E-9)

MN

MOD

Alarm

Indicates the operating status of the MOD. When any failure occurs in the modulator section, Alarm is issued.

MJ

IF CABLE SHORT

Alarm

IF cable between IDU - ODU is in short condition.

MJ

INPHASE.

Status

In - Phase indicates the received signal DADE status between No.1 and No.2 MODEM interfaces are in Phase
condition. In this condition, hitless switch over is available.

L2SYNC LOSS

Alarm

Loss of frame synchronization of GFP frames on MODEM port.

MJ

RDI

Alarm

RDI indication reception alarm on MODEM port

MJ

UAE.

Alarm

UAE alarm. Indicates the occurrence of an Unavailable state.

MN

TDM/AMR Range Mismatch

Alarm

Mismatch condition when the mapping number of E1 channels are different between TX and RX modem ports or
mismatch condition of selected RX AMR modulation range and TX AMR modulation range.

MJ

TX SW Reverse Request

Status

TXSW request signal receiving condition from the opposite station:

TX SW Lock in Status

Status

TXSW Lockin state

Unlocked

Alarm

Wireless synchronization status of the local side.

MJ

MODEM PS OFF

Status

Indicate power off condition of power switch which is in front of MODEM-A card.

STM-1 Alarm and Status


Indication

Category

Descriptions

Severity

Unequipped (STM1-A)

Alarm

Reserved and installed optional package is removed from optional slot.

MJ

Type Mismatch(STM1-A)

Alarm

The equipped type of interface is different from configured type.

MJ

Communication
FAIL(STM1-A)

Alarm

Communication failure of equipment internal control communication.

MJ

Module(STM1-A)

Alarm

Equipment fault

MJ

BUS ERROR TX

Alarm

Data communication BUS failure condition in TX direction from STM-1 Card.

MJ

BUS ERROR RX

Alarm

Data communication BUS failure condition in RX direction from STM-1 Card.

MJ

SNCP PPS-FAIL

Alarm.

SNCP Path Protection Failure

MJ

SNCP Protection Status

Status

SNCP Path Protection Status indication which indicates [FS, SF, SD, MS, NR] condition.

APS Protection Status

Status

APS Line Protection Status indication which indicates {FS,SF,SD,MS,NR} condition.

APS Lock-in Status

Status

APS protection Lock-in Condition.

SFP_Type Mismatch
(STM1)

Alarm

Mismatch between SFP on LCT and installed SFP.

MJ

SFP Unequipped (STM1)

Alarm

A SFP is removed.

MJ

STM-1LOS

Alarm

LOS detection on STM-1 Optical port.

MJ

STM-1 TF

Alarm

Transmit Failure detection on STM-1 optical port.

MJ

RS LOF

Alarm

SDH Frame synchronization lost in RS (Regenerator Section) on STM-1 port.

MJ

RS TIM

Alarm

Trace Identifier Mismatch detected in RS (Regenerator Section) on STM-1 port.

MJ

RS EXC

Alarm

B1 Byte error occurrence in RS (Regenerator Section) on STM-1 port.

MJ

RS DEG

Alarm

B1 byte error in RS (Regenerator Section) (RS - Degraded) on STM-1 port.

MN

MS AIS

Alarm

AIS detection in MS (Multiplex Section) on STM-1 port.

MJ

MS RDI

Alarm

Remote Defect Indication reception in MS (Multiplex Section) on STM-1 port.

MJ

AU AIS

Alarm

AIS detection in AU (Administrative Unit) on STM-1 port.

MJ

STM-1 Alarm and Status


Indication

Category

Descriptions

Severity

AU LOP

Alarm

Loss of AU pointer happens on STM-1 port.

MJ

HP UNEQ

Alarm

HOP (Higher Order Path) Unequipped occurrence on STM-1 port.

MJ

HP TIM

Alarm

HOP (Higher Order Path) Trace Identifier mismatch occurrence on STM-1 port.

MJ

HP-PLM

Alarm

Payload Label Mismatch occurrence in HOP (Higher Order Path) on STM-1 port.

MJ

HP-RDI

Alarm

RDI (Remote Defect Indication) reception in HOP (Higher Order Path) on STM-1 port.

MJ

HP-LOM

Alarm

Loss of Multi-Frame on STM-1 port.

MJ

TU -AIS

Alarm

In TU (Tributary Unit), AIS detection on STM-1 port.

MJ

TU -LOP

Alarm

Loss of TU Pointer on STM-1 port.

MJ

LP -UNEQ.

Alarm

LP (Lower Order Path) Unequipped occurrence on STM-1 port.

MJ

LP RDI

Alarm

Remote Defect Indicate reception by an LP (Lower Order Path) on STM-1 port.

MJ

LP PLM

Alarm

Payload Label Mismatch Failure occurrence by an LP (Lower Order Path) on STM-1 port.

MJ

ALS

Status

Indication of automatic laser shutdown condition at STM-1 optical port.

RS UAS Status

Status

UAS status indication on STM port (Repeater Section)

STM-1 AIS Generated

Status

AIS generation condition on STM port.

PJE

Status

Pointer justification Event indication at STM port.

16E1 alarm and Status


Indication

Category

Descriptions

Severity

Unequipped (16E1)

Alarm

Reserved and installed optional package is removed from optional slot.

MJ

Type Mismatch(16E1)

Alarm

The equipped type of interface is different from configured type.

MJ

Communication FAIL(16E1)

Alarm

Communication failure of equipment internal control communication.

MJ

Module(16E1)

Alarm

Equipment fault

MJ

BUS ERROR TX

Alarm

Data communication BUS failure condition in TX direction from STM-1 Card.

MJ

BUS ERROR RX

Alarm

Data communication BUS failure condition in RX direction from STM-1 Card.

MJ

E1 LOS

Alarm

No signal input on E1 port

MJ

E1 AIS

Status

ALARM/Status category can change according to " AIS Received Condition


Setting

MJ / -

Usage Error

Alarm

Unused E1 CH input signal detection.

MN

E1 AIS Generated

Status

AIS generation condition on every E1 Channels.

AUX-A Option Card

Indication

Category

Descriptions

Severity

Unequipped (AUX-A)

Alarm

Reserved and installed optional package is removed


from optional slot.

MJ

Type Mismatch(AUX-A)

Alarm

The equipped type of interface is different from


configured type.

MJ

Communication
FAIL(AUX-A)

Alarm

Communication failure of equipment internal control


communication.

MJ

Module(AUX-A)

Alarm

Equipment fault

MJ

BUS ERROR TX

Alarm

Data communication BUS failure condition in TX


direction from STM-1 Card.

MJ

BUS ERROR RX

Alarm

Data communication BUS failure condition in RX


direction from STM-1 Card.

MJ

Item Name (Input-x)


Item Name (Cluster-x)

Status/
Alarm

HKA Status Indication {Alarm, Normal} for every


HKA input.

- or
Severity selectable

Item Name (Output-x)

Status

HKC Status {Alarm, Normal} for every HKC output.

GbE-A option card


Indication

Category

Descriptions

Severity

Unequipped (GBE-A)

Alarm

Reserved and installed optional package is


removed from optional slot.

MJ

Type Mismatch(GBEA)

Alarm

The equipped type of interface is different


from configured type.

MJ

Communication
FAIL(GBE-A)

Alarm

Communication failure of equipment


internal control communication.

MJ

Module(GBE-A)

Alarm

Equipment fault

MJ

BUS ERROR TX

Alarm

Data communication BUS failure condition


in TX direction from STM-1 Card..

MJ

BUS ERROR RX

Alarm

Data communication BUS failure condition


in RX direction from STM-1 Card..

MJ

SFP_Type Mismatch
(ETH)

Alarm

Mismatch between SFP on LCT and


installed SFP.

MJ

SFP Unequipped
(ETH)

Alarm

A SFP is removed.

MJ

LAN LINK

Alarm

LINK of the LAN Port is disconnected.

MJ

Speed & Duplex

Status

LAN Port setting (Speed&Duplex)

Equipment Common alarm and Status-1


Indication

Category

Descriptions

Severity

MODULE (Main Board)

Alarm

Equipment fault

MJ

BUS ERROR

Alarm

Data communication BUS failure condition.

MJ

Unequipped (PS)

Alarm

Installed Power Supply Module is removed from PS slot.

MJ

Power Supply

Alarm

Alarm in case of power failure.

MJ

FAN Fail

Alarm

FAN failure

MJ

Unequipped (FAN)

Alarm

Installed FAN Module is removed from FAN slot.

MJ

Unequipped (CLK2M)

Alarm

Installed CLK2M Module is removed from Main Card.

MJ

Type Mismatch (CLK2M)

Alarm

The equipped type of interface is different from configured type.

MJ

IDU CPU Alarm

Alarm.

IDU CPU Alarm

MN

Memory Failure

Alarm

Detection of memory failure

MJ

USB Failure

Alarm

USB memory failure indication

MJ

Temperature

Alarm

The temperature is over the threshold

MN

Maintenance

Status

Maintenance declaration.

CLK FAIL

Alarm

Reference Clock Failed.

MN

CLK Drift

Alarm

Reference Clock source Frequency drift condition

MN

LTI

Alarm

Loss of all incoming timing source

MJ

CLK Status Changed

Status

Reference clock change status


(1) (Locked Ref1)
(2) (Locked Ref2)
(3) (Locked Ref3)
(4) Holdover
(5) Freerun

SSM FAIL

Alarm

Received Sync Status Message value is in unstable condition.

MN

Quality Level

Status

Received quality level condition of each timing source.

Squelch

Status

The condition of External CLK Output is in squelch condition.

Equipment common Alarm and Status -2


Indication

Category

Descriptions

Severity

EXT CLK Condition

Status

Condition level of External CLK output.

EXT CLK LOS

Alarm

Loss of Signal condition of External clock input.

MN

EXT CLK AIS

Alarm

AIS (Alarm Indication Signal) condition of External Clock input.

MN

EXT CLK LOF

Alarm

Loss of frame condition of External Clock input.

MN

EXT CLK Loop

Alarm

Indication of EXTERNAL clock input is used as EXTERNAL clock output.

MJ

Item Name (Input-x)


Item Name (Cluster-x)

Status/
Alarm

HKA Status Indication {Alarm, Normal} for every HKA input.

- or Severity
selectable

Item Name (Output-x)

Status

HKC Status {Alarm, Normal} for every HKC output.

E1 LOS

Alarm

No signal input on E1 port

MJ

E1 AIS

Status

PDH AIS
ALARM/Status category can change according to " AIS Received Condition Setting

MJ / -

Usage Error

Alarm

Unused E1 CH input signal detection.

MN

E1 AIS Generated

Status

AIS generation condition on every E1 Channels.

ETH LOS

Alarm

LOS detection at Optical Ethernet port.

MJ

ETH TF

Alarm

Transmit Fail detection at Optical Ethernet port.

MJ

SFP_Type Mismatch (ETH)

Alarm

Mismatch between SFP on LCT and installed SFP.

MJ

SFP Unequipped (ETH)

Alarm

A SFP is removed.

MJ

LAN LINK

Alarm

LINK of the LAN Port is disconnected.

MJ

Speed & Duplex

Status

LAN Port setting (Speed&Duplex)

ETH-OAM LOC

Alarm

ETH-OAM Mismerge

Alarm

Ether OAM Mismatch Detection notice.

MN

ETH-OAM Unexpected Period

Alarm

Ether OAM Unexpected MEP and Ether OAM Unexpected Period detection notice

MN

ETH-OAM RDI

Alarm

Ether OAM RDI reception detection notice

MJ

MJ

Equipment common Alarm and Status -3


Indication

Category

Descriptions

Severity

RSTP New Root Bridge Detect

Status

The notice in which new RootBridge was detected at the time of SpanningTree processing

RSTP Topology Changed

Status

The notice in which a Topology change was detected at the time of SpanningTree processing

RSTP Protocol Migration

Status

The notice which received a Bridge protocol Data Units different in classification of RSTP/STP at the
time of SpanningTree processing

RSTP Invalid BPDU Received

Status

Invalid BPDU message at the time of SpanningTree processing

LLF Message Timeout

Status

Loss of a conditional signaling in which the LLF control signal should be received continuously from
the opposite radio equipment.

LLF

Status

LLF force a LINKDOWN status. The Ethernet port under "edge" mode becomes LINKDOWN.

The highest
Severity will
be reported

IDU TOTAL ALM

Alarm

IDU TOTAL ALM

Total FDB Full

Status

The number of DynamicEntryDynamic Entry in L2Switch has reached the maximum number.

FDB Full

Status

FDB Full indication specified per VLAN basis.

ABBREVIATIONS-1
Adjacent Channel Alternate

CIR

Committed Information Rate

DMM

Delay Measurement Message

Polarization

CKT

Circuit

DMR

Delay Measurement Reply

Adjacent Channel Co-Polarization

CLK

Clock

DO

Data-out

ACK

Acknowledgement

CMF

Channel Mismatch Failure

DSCP

Differentiated Services Code Point

AGC

Automatic Gain Control

CMI

Coded Mark Inversion

DUP

Duplexer

AIS

Alarm Indication Signal

CONV

Converter

DXC

Digital Cross Connect

ALM

Alarm

CORBA

Common Object Request Broker

E1

E-carrier level 1

Architecture

ACAP
ACCP

ALS

Auto Laser Shutdown

EBS

Express Burst Size

AMR

Adaptive Modulation Radio

CoS

Class of Service

EIR

Excess Information Rate

ANT, Ant.

Antenna

CPU

Central Processing Unit

EMC

Electro Magnetic Compatibility

APS

Automatic Protection Switch

CR

Critical

EML

Element Management Layer

ATT

Attenuator

CRC

Cyclic Redundancy Check

EMS

Element Management System

ATPC

Automatic Transmitter Power Control

CS

Channel Separation

EOW

C Order Wire

AU

Administrative Unit

CTRL

Control

EPS

ETH-Protection Switch

AUX

Auxiliary

CV

near end Code Violation

EQL

Equalizer

Ave

Average

CW

Carrier Wave

ERP

ETH-Ring Protection Switch

BBE

Background Block Error

DA

Destination Address

ES

Errored Seconds

BER

Bit Error Rate

DADE

Differential Absolute Delay Equalizer

ETH-CC

ETH-Continuity Check function

BPF

Band Pass Filter

DB

Database

ETH-LB

ETH-Loopback function

BS

Base Station

DC

Direct Current

ETH-LBM

ETH-Loopback Message

BSC

Base Station Controller

DCN

Data Communication Network

ETH-LBR

ETH-Loopback Reply

BTS

Base Transceiver Station

DEG

Degraded

ETH-LB

ETH-Loopback function

CAPEX

Capital Expenditure

DEI

Drop Eligible Indicator

ETH-LT

ETH- Link Trace function

CBS

Committed Burst Size

DEM

Demodulator

ETH-LTM

ETH-Link Trace Message

CCDP

Co-Channel Dual Polarization

Des(Dest)

Destination

ETH-LTR

ETH-Link Trace Reply

CCM

Continuity Check Message

DI

Data-in

ETH-OAM

Ethernet Operations, Administration

CEPT

Conference of European Postal &

DL

Download

Telecommunication Administration

DM

Delay Measurement

and Maintenance

10

ABBREVIATIONS-2
ETH-OAM LB

ETH-OAM Loopback

ETH-OAM LT

ETH-OAM Link Trace

ETH-RDI

ETH-Remote Defect Indication function

ETSI

European Telecommunications

ID

Identification

IDU

Indoor Unit

IE

Internet Explorer

IEC

International Electro technical

Standards Institute
EXC

Electrical Cross Connect

E-to-E.

End-to-End

Fail

Failure

F/B

Front Back Ratio

FCS

Frame Check Sequence

FDB

Forwarding Database

FE

Fast Ethernet

FEC

Forward Error Correction

FEBBE

Far End Background Block Error

FEES

Far End Errored Seconds

FESES

Far End Severely Errored Seconds

FEUAS

Far End Unavailable Seconds

FPGA

Field Programmable Gate Array

F/W

Firmware

GbE, GBE

Gigabit Ethernet

3GPP

Third Generation Partnership Project

GUI

Graphical User Interface

Horizontal

HDB

High Density Bipolar

HK

House Keeping

HP

Higher order Path

HYB

Hybrid

H/W

Hardware

Commission
IEEE

Institute of Electrical and Electronics


Engineers

I/F

Interface

IF

Intermediate Frequency

IHG

iPASOLINK High Grade

IN

Input

INTFC

Interface

I/O

Input/Output

IP

Internet Protocol

ITU

International Telecommunication Union

ITU-R

Radio Communication Sector of ITU

ITU-T

Telecommunication Sector of ITU

L2SW

Layer2-Switch

LAN

Local Area Network

LB

Loopback

LBM

Loopback Message

LCD

Loss of Cell Delineation

LCT

Local Craft Terminal

LDPC

Low Density Parity Check

LED

Light Emitting Diode

Lev.

Level

LLF

Link Loss Forwarding

LM

Loss Measurement

LMM

Loss Measurement Message

LNA

Low Noise Amplifier

LO

Local Oscillator

LOC

Loss of Continuity

LOF

Loss of Frame

LOM

Loss of Multiframe

LOP

Loss of Pointer

LO REF

Local Reference Signal Loss

LOS

Loss of Signal

LP

Lower order Path

LPM

Link Performance Monitor

LT

Link Trace

LTI

Loss of incoming Timing Input

LTM

Link Trace Message

MAC

Media Access Control

MAIN

Main

MAINT

Maintenance

MAX

Maximum

Mdev

Mean Deviation

MDCPU

MODEM CPU

MDI

Medium Dependent Interface

MDIX

Medium Dependent Interface


Crossover

MD4

Message Digest Algorithm 4

MD5

Message Digest Algorithm 5

MEG

Maintenance Entity Group

MEM

Memory

MEP

MEG End Point

11

ABBREVIATIONS-3
MIN

Minimum

Octs

Octets

PMC

PASOLINK Management Card

MIP

Maintenance Intermediate Point

ODU

Out-Door Unit

PMON

Performance Monitor

MIX

Mixer

OFS

Out of Frame Second

PNMSj

PASOLINK Network Management

MJ

Major

OMT

Ortho-Mode Transducer

MMC

Multi Media Card

OPEX

Operational expenditure

PPI

PDH PHY Interface

MME

Mobility Management Entity

OPP

Opposite

ppm

parts per million

MMG

Mismerge

OPR

Operation

PPP

Point-to-Point Protocol

MN

Minor

OPT

Optical

PPS

Path Protection Switch

MOD

Modulator

OSPF

Open Shortest Path First

PQ

Priority Queuing

MODEM

Modulator Demodulator

OSS

Operation Support System

PRM

Parameter

MON

Monitor

OUT

Output

PROT

Protection

MPX

Multiplexer

OW

Oder Wire

PS

Power Supply

MS

Multiplex Section

PA

Power Amplifier

PSC

Protection Switching Counts

MSC

Mobile Switching Center

PBR

Pressurizable Type B, flange profile

PSD

Protection Switching Duration

MSDU

MAC Service Data Unit

square Rectangular

PWR

Power

MSP

Multiplex Section Protection

PCP

Priority Code Point

QAM

Quadrature Amplitude Modulation

MTBF

Mean Time Between Failure

PDH

Plesiochronous Digital Hierarchy

QoS

Quality of Service

MTPC

Manual Transmitter Power Control

PDU

Protocol Data Unit

QPSK

Quadrature Phase Shift Keying

MUX

Multiplexing Equipment

PGM

Program

RCVR

Recover

N/A

Not Applicable

PHY

Physical

REF

Reference

NBI

Northbound Interface

PIR

Peak Information Rate

REM

Remote

NE

Network Element

PJE

Pointer Justification Event

RDI

Remote Defect Indication

NML

Network Management Layer

PJE-N

Pointer Justification Event Negative Stuff

RF

Radio Frequency

NMS

Network Management System

PJE-P

Pointer Justification Event Positive Stuff

RFS

Radio Frequency Systems

OAM

Operation Administration and

PKG

Package

RL

Relay

Maintenance

Pkts

Packets

RMON

Remote Network Monitoring

Occur

PLM

Payload Label Mismatch

RNC

Radio Network Controller

OCR

System Java Version

12

ABBREVIATIONS-4
RPL

Ring Protection Link

SUB

Substitute

UNEXP

Unexpected

RS

Regenerator Section

SW

Switch

Unicast DMR

Unicast Delay Measurement Reply

RS-232

Recommended Standard 232

S/W

Software

UNM

Unexpected MEP

RSL

Received Signal Level

SWG

Switch Group

UNP

Unexpected Period

RST

Regenerator Section Termination

SYNC

Synchronous

USB

Universal Serial Bus

RSTP

Rapid Spanning Tree Protocol

TCI

Tag Control Information

Vertical

RX

Receiver

TCN

Threshold Crossing Notification

Volt

SC

Service Channel

TDM

Time Division Multiplex

VC

Virtual Channel

SD

Space Diversity

TDMoP

TDM over Packet

VLAN

Virtual LAN

SDH

Synchronous Digital Hierarchy

TEMP

Temperature

VP

Virtual Path

SEG

Segment

TERM

Terminal

VPN

Virtual Private Network

SEP

Severely Errored Period

TF

Transmit Fail

VSWR

Voltage Standing Wave Ratio

SES

Severely Errored Seconds

TIM

Trace Identifier Mismatch

WDM

Wavelength Division Multiplexing

SFP

Small Form factor Pluggable

TLV

Type Length Value

Web

World Wide Web

SGMI

Security Gateway Management

TM

Through Mode

WG

Waveguide

Interface

TNC

Threaded Neil Councilman

WR

Warning

SMS

Synchronous Multiplexing System

ToS

Type of Service

WRR

Weighted Round Robin

SMU

Source Measure Unit

TPID

Tag Protocol Identifier

WS

Wayside

SNCP

Sub-network Connection Protection

TQC

Total Quality Control

XCTRL

XPIC Control

SNMP

Simple Network Management Protocol

TTL

Time To Live

X-DEM

XPIC Demodulator

SP

Strict Priority

TU

Tributary Unit

XFP

10(X) Gigabit Small Form Factor

SPD

Speed

TX

Transmitter

SRC

Source MAC Address

UAE

UAS Event

XIF

XPIC IF

STAT

Status

UAS

Unavailable Seconds

XPD

Cross Polarization Discrimination Ratio

STD

Standard

UL

Upload

XPIC

Cross Polarization Interference

STM

Synchronous Transport Module

UNEQ

Unequipped

STP

Spanning Tree Protocol

Pluggable

Canceller
XREF

XPIC Reference

13

Vous aimerez peut-être aussi