Académique Documents
Professionnel Documents
Culture Documents
1.
06.05.2004
13.08.2003
100816
Product name:
Company/undertaking identification
2.
Company:
Composition/information on ingredients
Aqueous solution of inorganic and organic compounds.
Hazardous ingredients:
Name according to EC Directives:
CAS-No.
EC No.
EC-Index-No.
Classification
Content:
ammonia solution
7664-41-7
231-635-3
007-001-01-2
C; R34
N; R50
5 - < 10 %
Potassium cyanide
151-50-8
205-792-3
006-007-00-5
T+; R26/27/28
R32
N; R50/53
0.25 - < 1 %
3.
Hazards identification
Harmful by inhalation, in contact with skin and if swallowed. Irritating to eyes, respiratory system
and skin. Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic
environment.
4.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 1 of 6
5.
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Reaktionskvette
Fire-fighting measures
Suitable extinguishing media:
In adaption to materials stored in the immediate neighbourhood.
Special risks:
Non-combustible. Ambient fire may liberate hazardous vapours. The following may develop in event of
fire: nitrogen oxides.
Special protective equipment for fire fighting:
Do not stay in dangerous zone without self-contained breathing apparatus. In order to
avoid contact with skin, keep a safety distance and wear suitable protective clothing.
Other information:
Contain escaping vapours with water. Prevent fire-fighting water from entering surface water or
groundwater.
6.
7.
Storage:
Tightly closed. At +15C to +25C.
The data apply to the entire pack.
8.
Ammonia
20 ml/m3
14 mg/m3
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 2 of 6
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Reaktionskvette
Respiratory protection:
Eye protection:
required
Hand protection:
In full contact:
natural latex
0.6 mm
> 30 Min.
Glove material:
Layer thickness:
Breakthrough time:
In splash contact:
nitrile rubber
0.11 mm
> 60 Min.
Glove material:
Layer thickness:
Breakthrough time:
9.
liquid
light yellow
not available
not available
not available
not available
not available
lower
not available
upper
Density
Solubility in Water
not available
(20 C)
~ 1.03
g/cm3
not available
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 3 of 6
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Reaktionskvette
Substances to be avoided
acids, anhydrides, halogenating agents, nitriles. Violent reactions possible with: oxidizing agent.
Further information
incompatible with various metals and metal alloys (i.a. zinc, copper).
Further data
Further hazardous properties cannot be excluded.
The product should be handled with the care usual when dealing with chemicals.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 4 of 6
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Reaktionskvette
Packaging:
Merck product packaging must be disposed of in compliance with the country-specific regulations
or must be passed to a packaging return system. Under www.retrologistik.de you will find special
information on the respective national conditions as well as contact partners.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 5 of 6
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Reaktionskvette
Xn
Harmful
20/21/22-52/53
S-phrases:
contains:
36/37
Potassium cyanide
Regional representation:
This information is given on the authorised Safety Data Sheet
for your country.
The information contained herein is based on the present state of our knowledge. It
characterizes the product with regard to the appropriate safety precautions. It does not
represent a guarantee of the properties of the product.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 6 of 6
1.
26.08.2004
06.05.2004
100816
Product name:
Company/undertaking identification
2.
Company:
Composition/information on ingredients
Aqueous solution.
Hazardous ingredients:
Name according to EC Directives:
CAS-No.
EC No.
EC-Index-No.
Classification
Content:
Hydroxylammonium chloride
5470-11-1
226-798-2
612-123-00-2
Xn; R22-48/22
Xi; R36/38-43
N; R50
5 - < 10 %
Formaldehyde
50-00-0
200-001-8
605-001-00-5
1-<3%
methanol
67-56-1
603-001-00-X
F; R11
T; R23/24/25-39/23/24/25
0.1 - < 1 %
200-659-6
3.
Hazards identification
Limited evidence of a carcinogenic effect. May cause sensitization by skin contact.
4.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 1 of 6
5.
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Mn-1K
Fire-fighting measures
Suitable extinguishing media:
In adaption to materials stored in the immediate neighbourhood.
Special risks:
Non-combustible. Ambient fire may liberate hazardous vapours.
Special protective equipment for fire fighting:
Do not stay in dangerous zone without self-contained breathing apparatus. In order to
avoid contact with skin, keep a safety distance and wear suitable protective clothing.
Other information:
Prevent fire-fighting water from entering surface water or groundwater.
6.
7.
Storage:
Tightly closed. At +15C to +25C.
The data apply to the entire pack.
8.
Formaldehyde
C 3:owing possible carcinogenic effects for man
Sh Danger of sensitization of the skin
Name
Sensitization
Hydroxylammonium chloride
Sh Danger of sensitization of the skin
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 2 of 6
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Mn-1K
Eye protection:
required
Hand protection:
In full contact:
butyl rubber
0.7 mm
> 480 Min.
Glove material:
Layer thickness:
Breakthrough time:
In splash contact:
butyl rubber
0.7 mm
> 480 Min.
Glove material:
Layer thickness:
Breakthrough time:
9.
liquid
colourless
odourless
not available
not available
not available
not available
not available
lower
not available
upper
not available
(20 C)
1.03
(20 C)
soluble
The Safety Data Sheets for catalog items are also available at www.chemdat.info
g/cm3
Page 3 of 6
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Mn-1K
Substances to be avoided
The generally known reaction partners of water.
Further data
Further hazardous properties cannot be excluded.
The product should be handled with the care usual when dealing with chemicals.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 4 of 6
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Mn-1K
Packaging:
Merck product packaging must be disposed of in compliance with the country-specific regulations
or must be passed to a packaging return system. Under www.retrologistik.de you will find special
information on the respective national conditions as well as contact partners.
Xn
Harmful
40-43
S-phrases:
contains:
36/37
Formaldehyde
Hydroxylammonium chloride
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 5 of 6
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Mn-1K
Highly flammable.
Harmful if swallowed.
Toxic by inhalation, in contact with skin and if swallowed.
Causes burns.
Irritating to eyes and skin.
Toxic: danger of very serious irreversible effects through inhalation, in contact
with skin and if swallowed.
Limited evidence of a carcinogenic effect.
May cause sensitization by skin contact.
Harmful: danger of serious damage to health by prolonged exposure if swallowed.
Very toxic to aquatic organisms.
Regional representation:
This information is given on the authorised Safety Data Sheet
for your country.
The information contained herein is based on the present state of our knowledge. It
characterizes the product with regard to the appropriate safety precautions. It does not
represent a guarantee of the properties of the product.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 6 of 6
1.
06.05.2004
03.09.2003
100816
Product name:
Company/undertaking identification
2.
Company:
Composition/information on ingredients
Aqueous solution of organic compounds.
Hazardous ingredients:
Name according to EC Directives:
CAS-No.
EC No.
EC-Index-No.
Hydroxylammonium chloride
5470-11-1
226-798-2
612-123-00-2
Classification
Content:
Xn; R22-48/22
Xi; R36/38-43
N; R50
10 - < 25 %
3.
Hazards identification
May cause sensitization by skin contact. Harmful: danger of serious damage to health by prolonged
exposure if swallowed.
4.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 1 of 5
5.
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Mn-2K
Fire-fighting measures
Suitable extinguishing media:
In adaption to materials stored in the immediate neighbourhood.
Special risks:
Non-combustible. Ambient fire may liberate hazardous vapours. The following may develop in event of
fire: hydrochloric acid, nitrogen oxides.
Special protective equipment for fire fighting:
Do not stay in dangerous zone without self-contained breathing apparatus. In order to
avoid contact with skin, keep a safety distance and wear suitable protective clothing.
Other information:
Contain escaping vapours with water. Prevent fire-fighting water from entering surface water or
groundwater.
6.
7.
Storage:
Tightly closed. At +15C to +25C.
The data apply to the entire pack.
8.
Hydroxylammonium chloride
Sh Danger of sensitization of the skin
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 2 of 5
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Mn-2K
Respiratory protection:
Eye protection:
required
Hand protection:
In full contact:
nitrile rubber
0.11 mm
> 480 Min.
Glove material:
Layer thickness:
Breakthrough time:
In splash contact:
nitrile rubber
0.11 mm
> 480 Min.
Glove material:
Layer thickness:
Breakthrough time:
9.
liquid
colourless
odourless
not available
not available
not available
not available
not available
lower
not available
upper
Density
Solubility in
water
not available
(20 C)
1.13
(20 C)
soluble
The Safety Data Sheets for catalog items are also available at www.chemdat.info
g/cm3
Page 3 of 5
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Mn-2K
Substances to be avoided
The generally known reaction partners of water.
Further data
Further hazardous properties cannot be excluded.
The product should be handled with the care usual when dealing with chemicals.
Packaging:
Merck product packaging must be disposed of in compliance with the country-specific regulations
or must be passed to a packaging return system. Under www.retrologistik.de you will find special
information on the respective national conditions as well as contact partners.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 4 of 5
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Mn-2K
Xn
Harmful
43-48/22
S-phrases:
contains:
24-37
Hydroxylammonium chloride
Harmful if swallowed.
Irritating to eyes and skin.
May cause sensitization by skin contact.
Harmful: danger of serious damage to health by prolonged exposure if swallowed.
Very toxic to aquatic organisms.
Regional representation:
This information is given on the authorised Safety Data Sheet
for your country.
The information contained herein is based on the present state of our knowledge. It
characterizes the product with regard to the appropriate safety precautions. It does not
represent a guarantee of the properties of the product.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 5 of 5
1.
06.05.2004
13.08.2003
100816
Product name:
Company/undertaking identification
2.
Company:
Composition/information on ingredients
CAS-No.:
M:
Formula Hill:
3.
7732-18-5
18.02 g/mol
H2O
EC-No.:
231-791-2
Hazards identification
No hazardous product as specified in Directive 67/548/EEC.
4.
5.
Fire-fighting measures
Suitable extinguishing media:
In adaption to materials stored in the immediate neighbourhood.
Special risks:
none
6.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 1 of 4
7.
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Packungsblindkvette
Storage:
Tightly closed. At +15C to +25C.
The data apply to the entire pack.
8.
not required
Eye protection:
not required
Hand protection:
not required
Industrial hygiene:
not required
9.
liquid
colourless
odourless
(20 C)
neutral
(20 C)
0.952
mPa*s
100
not applicable
not applicable
lower
not applicable
upper
Vapour pressure
Density
Solubility in
ethanol
not applicable
(20 C)
23
hPa
(20 C)
1.00
g/cm3
(20 C)
soluble
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 2 of 4
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Packungsblindkvette
Substances to be avoided
The generally known reaction partners of water.
Further information
none
Packaging:
Merck product packaging must be disposed of in compliance with the country-specific regulations
or must be passed to a packaging return system. Under www.retrologistik.de you will find special
information on the respective national conditions as well as contact partners.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 3 of 4
100816
Manganese Cell Test Method: photometric 0.10 - 5.00 mg/l Mn 25 Tests
Spectroquant
Packungsblindkvette
-------
Regional representation:
This information is given on the authorised Safety Data Sheet
for your country.
The information contained herein is based on the present state of our knowledge. It
characterizes the product with regard to the appropriate safety precautions. It does not
represent a guarantee of the properties of the product.
The Safety Data Sheets for catalog items are also available at www.chemdat.info
Page 4 of 4