Vous êtes sur la page 1sur 5604

Parameter ID

Parameter Name

NE

ABCDownQuality

Downlink Quality
Threshold in Assigning
Better Cell

BSC6900

ABCUpQuality

Uplink Quality Threshold


BSC6900
in Assigning Better Cell

ABCWaitMaxTime

Maximum Better Cell


Assigning Duration

BSC6900

ABISBYPASSMODE

Abis ByPass Mode

BSC6900

ABISFCEN

SDCCH Congestion Flow


Control Allowed

BSC6900

AbisFCTimer1

Abis Flow Control Timer 1 BSC6900

AbisFCTimer2

Abis Flow Control Timer 2 BSC6900

ABISIDLETSALLOC

Abis Idle TS Allocate


Strategy

BSC6900

ABISIDLETSCFGSWITCH

Abis Idle TS Configure


Switch

BSC6900

AbisJamThreshold2StartLs

Abis Jam Rate for BTS


Local Switch

BSC6900

ABISRESADJTCHHFUNSW

TCHH Function Switch

BSC6900

ABISTSFREETM

Timer of Releasing Abis


Timeslot

BSC6900

AbisVer

Abis Interface Tag

BSC6900

ABLASTTIME

Duration of BTS
Collecting AB[100
Millisecond]

BSC6900

AbnormalMosThreshold

Abnormal Voice MOS


Threshold

BSC6900

ACCBURST

Access Burst Type

BSC6900

ACCCONTROLCLASS

Access Control Class

BSC6900

ACCCTRLEN

Access Control Allowed

BSC6900

ACCCTRLPY

Access Control Policy

BSC6900

ACCESSOPTILAY

Incoming-to-BSC HO
Optimum Layer

BSC6900

ACCINDEX

Access Control Policy


Index

BSC6900

AccStaServiceType

PS Initial Access Service


Type

BSC6900

ACCWPOS

Starting Point of the


Access Control Window

BSC6900

ACCWSIZE

Access Control Window


Size

BSC6900

ACCWSP

Sliding Speed of the


Access Control Window

BSC6900

ACFC

Support Address and


Control Field Compress

BSC6900

ACFC

Address and control field


BSC6900
compress

ACOOPERATPAGINGSWITC A Interface Paging CoH


ordination Switch

BSC6900

ACS

Additional Reselect
Parameter Indication

BSC6900

ACTCDSETF

AMR ACS[F]

BSC6900

ACTCDSETH

AMR ACS[H]

BSC6900

ACTCDSETWB

AMR ACS[WB]

BSC6900

ACTL2REEST

Activate L2 Reestablishment

BSC6900

ACTTIME

Valid Time of BTS


Resource Activation

BSC6900

ACVLTHD

AC Voltage Lower
Threshold

BSC6900

ACVOLALARMH

AC Overvoltage Alarm
Threshold

BSC6900

ACVOLALARML

AC Undervoltage Alarm
Threshold

BSC6900

ACVUTHD

AC Voltage Upper
Threshold

BSC6900

ADAPTASSIGNMENTFLOW

Assignment Procedure in
BSC6900
Intra-Cell HO Allowed

ADDR

Communication Address

BSC6900

AddTransBwInt

Sub-Link Bandwidth
Request Interval When
Not Congested

BSC6900

AddTransBwNum

Bandwidth for Secondary


Link When Not
BSC6900
Congested

ADEF

External Alarm Customer


BSC6900
Definition Switch

ADJBSCDPC

Adjacent BSC DPC

BSC6900

ADJMODE

Adjustment Mode

BSC6900

ADJUSTULMCSTYPE

Support EGPRS Uplink


MCS Dynamic Adjust

BSC6900

ADLDACT

Auto Download Active


Function Switch

BSC6900

ADMODE

Auto Download Mode

BSC6900

ADMSTAT

Administrative State

BSC6900

ADMSTAT

Administrative State

BSC6900

ADMSTAT

Administrative State

BSC6900

ADTET

Offset Time Adjustment


End Time

BSC6900

ADTLOD

Load Threshold of Offset


BSC6900
Adjustment

ADTON

Offset Time Adjustment


Switch

BSC6900

ADTST

Offset Time Adjustment


Start Time

BSC6900

ADVALMMGRULETP

Advanced Alarm
Management Rule Type

BSC6900

ADVER1

BTS Software Version 1

BSC6900

ADVER2

BTS Software Version 2

BSC6900

AEC_Echo_Path_Delay

AEC Echo Path Delay

BSC6900

AEC_Echo_Return_Loss

AEC Echo Return Loss

BSC6900

AEC_Nlp_Gate

AEC Nlp Gate

BSC6900

AEC_Path_Delay

AEC Path Delay

BSC6900

AEC_SNR_Gate

AEC SNR Gate

BSC6900

AEC_Switch

AEC Switch

BSC6900

AECDetectThreshold

AEC Detect Threshold

BSC6900

AECDetectTime

AEC Detect Time

BSC6900

AFRDSBLCNT

AFR Radio Link Timeout

BSC6900

AFRSAMULFRM

AFR SACCH Multi-Frames BSC6900

AGPSRECEIVERID

GPS ID

BSC6900

AGPSRECEIVERTYPE

GPS type

BSC6900

AHRDSBLCNT

AHR Radio Link Timeout

BSC6900

AHRSAMULFRM

AHR SACCH Multi-Frames BSC6900

AID

Alarm ID

BSC6900

AID

Alarm ID

BSC6900

AID

Alarm ID

BSC6900

AID

Alarm ID

BSC6900

AID

Alarm ID

BSC6900

AID

Alarm ID.

BSC6900

AID

Alarm ID.

BSC6900

AIDDELAYPROTECTTIME

Aiding Delay Protect


Time

BSC6900

AIDST

Alarm Select Type

BSC6900

AIDST

Alarm Select Type

BSC6900

AInterMsgTrace

A Interface Msg
[End2end User Tracing]

BSC6900

AINTFFCDISCLUEN

A IF FC Discard LOC UP
Enable

BSC6900

AINTFFCDISCMOCEN

A IF FC Discard MOC
Enable

BSC6900

AINTFFCDISCMTCEN

A IF FC Discard MTC
Enable

BSC6900

AINTFFCDISCOSEN

A IF FC Discard Other
Service Enable

BSC6900

AINTFFCEN

A Interface Flow Control


Enable

BSC6900

AINTFFCMETHOD

A Interface Flow Control


Method

BSC6900

AINTFFCRSRATE1

A IF FC Service Rate in
Level 1

BSC6900

AINTFFCRSRATE2

A IF FC Service Rate in
Level 2

BSC6900

AINTFFCRSRATE3

A IF FC Service Rate in
Level 3

BSC6900

AINTFFCRSRATE4

A IF FC Service Rate in
Level 4

BSC6900

AINTFFCRSRATE5

A IF FC Service Rate in
Level 5

BSC6900

AINTFFCRSRATE6

A IF FC Service Rate in
Level 6

BSC6900

AIPCSDSRVRDNDLEV

CSD Service Redundancy


BSC6900
Level

ALC_Fix_Gain

ALC Fix Gain

BSC6900

ALC_Fix_Target_Level

ALC Fix Target Level

BSC6900

ALC_Max_Gain

ALC Max Gain

BSC6900

ALC_Max_Target_Level

ALC Max Target Level

BSC6900

ALC_Min_Target_Level

ALC Min Target Level

BSC6900

ALC_Mode

ALC Mode

BSC6900

ALC_Switch

ALC Switch

BSC6900

ALIVERETRY

Alive Retry

BSC6900

ALIVETIMER

Alive Timer

BSC6900

AllBw

Bandwidth

BSC6900

ALLOCDIFFTRX

Resource Reallocation to
BSC6900
Different Trx

ALLOCSINGLEPDCHFORSI Allocate One PDCH for


GNALLING
Signaling Data

BSC6900

ALLOWAMRHALFRATEUSE
Ratio of AMR-HR
RPERC

BSC6900

ALLOWEDADAMULTIPLEX

BSC6900

Allow EDA Multiplex

ALLOWEDMEASRPTMISSE Allowed Measure Report


DNUM
Missed Number

BSC6900

ALLOWHALFRATEUSERPER
Ratio of TCHH
C

BSC6900

ALLTSTYPE

Timeslot Type

BSC6900

ALLTSTYPE

Timeslot Type

BSC6900

ALMD0

Feed Tri. 0 TMA Low


Current Alarm Threhold

BSC6900

ALMD1

Feed Tri. 1 TMA Low


Current Alarm Threhold

BSC6900

ALMD2

Feed Tri. 2 TMA Low


Current Alarm Threhold

BSC6900

ALMD3

Feed Tri. 3 TMA Low


Current Alarm Threhold

BSC6900

ALMD4

Feed Tri. 4 TMA Low


Current Alarm Threhold

BSC6900

ALMD5

Feed Tri. 5 TMA Low


Current Alarm Threhold

BSC6900

ALMDISACDUR

Alarm Disappear
Accumulate Duration

BSC6900

ALMENABLE

Alarm Enable Flag

BSC6900

AlmId

Alarm ID.

BSC6900

ALMID

Alarm ID.

BSC6900

ALMLMTDOWN

Lower Alarm

BSC6900

ALMLMTUP1

Upper Alarm

BSC6900

ALMLMTUP2

Upper Alarm

BSC6900

ALMOCACDUR

Alarm Occurrence
Accumulate Duration

BSC6900

AlmOccurAccuTimeHThd

Alarm Occur
Accumulative Time
Threshold

BSC6900

AlmOccurAccuTimeLThd

Alarm Clear
Accumulative Time
Threshold

BSC6900

AlmOccurTimesHThd

Alarm Occur Times


Threshold

BSC6900

AlmOccurTimesLThd

Alarm Clear Times


Threshold

BSC6900

ALMPARACFGFLAG

Alarm Parameter
Configuration Enabled

BSC6900

ALMTP

Alarm Type

BSC6900

ALPHA

ALPHA

ALTIDECI

Antenna Altitude
Decimal Part

BSC6900

ALTITUDE

GPS antenna altitude

BSC6900

ALTITUDE

Antenna Altitude Int Part BSC6900

ALTITUDEIMP

GPS antenna altitude

BSC6900

ALVL

Alarm Severity

BSC6900

ALVL

Alarm Severity

BSC6900

AMPC0

Feed Tri. 0 TMA


Configuration

BSC6900

AMPC1

Feed Tri. 1 TMA


Configuration

BSC6900

AMPC2

Feed Tri. 2 TMA


Configuration

BSC6900

AMPC3

Feed Tri. 3 TMA


Configuration

BSC6900

AMPC4

Feed Tri. 4 TMA


Configuration

BSC6900

AMPC5

Feed Tri. 5 TMA


Configuration

BSC6900

AMRBTSPWRNUM

AMR BTS PC Class

BSC6900

AMRCALLPCALLOWED

Allow III Power Control


For AMR

BSC6900

AMRDADTHAW

AMR Downlink Adaptive


Threshold Allowed

BSC6900

AMRDLLEVFTLEN

AMR Filter Length for DL


RX_LEV

BSC6900

AMRDLPREDLEND

AMR DL MR. Number


Predicted

BSC6900

AMRDLQHTHRED

AMR DL Qual. Upper


Threshold

BSC6900

AMRDLQLTHRED

AMR DL Qual. Lower


Threshold

BSC6900

AMRDLQUAFTLEN

AMR Filter Length for DL


Qual.

BSC6900

AMRDLQUALBADTRIG

AMR DL Qual Bad Trig


Threshold

BSC6900

AMRDLQUALBADUPLEV

AMR DL Qual Bad


UpLEVDiff

BSC6900

AMRDLSSHTHRED

AMR DL RX_LEV Upper


Threshold

BSC6900

AMRDLSSLTHRED

AMR DL RX_LEV Lower


Threshold

BSC6900

AMRFULLTOHALFHOALLO
W

AMR F-H Ho Allowed

BSC6900

AMRFULLTOHALFHOATCB
ADJSTEP

AMR F-H Ho ATCB Adjust


BSC6900
Step

AMRFULLTOHALFHOATCBT AMR F-H Ho ATCB


HRESH
Threshold

BSC6900

AMRFULLTOHALFHOPATH
ADJSTEP

AMR F-H Ho Pathloss


Adjust Step

BSC6900

AMRFULLTOHALFHOPATHT AMR F-H Ho Pathloss


HRESH
Threshold

BSC6900

AMRFULLTOHALFHOQUAL AMR F-H Ho Qual.


THRESH
Threshold

BSC6900

AMRFULLTOHALFHOTHRE
AMR F-H Traffic Threshold BSC6900
SH

AMRHALFTOFULLHOATCB AMR H-F Ho ATCB


THRESH
Threshold

BSC6900

AMRHALFTOFULLHOPATH AMR H-F Ho Pathloss


THRESH
Threshold

BSC6900

AMRHALFTOFULLHOQUAL Allow AMR H-F QualityALLOW


based HO

BSC6900

AMRHALFTOFULLHOQUAL AMR H-F Ho Qual.


THRESH
Threshold

BSC6900

AMRHALFTOFULLHOTHRE
AMR H-F Traffic Threshold BSC6900
SH

AMRMAXADJPCVAL

AMR MAX Up Adj. PC


Value by Qual.

BSC6900

AMRMAXSTEP0

AMR MAX Down Adj.


Value Qual. Zone 0

BSC6900

AMRMAXSTEP1

AMR MAX Down Adj.


Value Qual. Zone 1

BSC6900

AMRMAXSTEP2

AMR MAX Down Adj.


Value Qual. Zone 2

BSC6900

AMRMAXVALADJRX

AMR MAX Up Adj. PC


Value by RX_LEV

BSC6900

AMRMRCOMPREG

AMR MR. Compensation


Allowed

BSC6900

AMRPCADJPERIOD

AMR PC Interval

BSC6900

AMRQUALSTEP

AMR MAX Down Adj. PC


Value by Qual.

BSC6900

AMRSADLUPGRADE

AMR SACCH Downlink


Power Upgrade

BSC6900

AMRTCHHPRIORALLOW

AMR TCH/H Prior Allowed BSC6900

AMRTCHHPRIORLOAD

AMR TCH/H Prior Cell


Load Threshold

BSC6900

AMRUADTHAW

AMR Uplink Adaptive


Threshold Allowed

BSC6900

AMRULLEVFTLEN

AMR Filter Length for UL


RX_LEV

BSC6900

AMRULPREDLEND

AMR UL MR. Number


Predicted

BSC6900

AMRULQHTHRED

AMR UL Qual. Upper


Threshold

BSC6900

AMRULQLOWTHRED

AMR UL Qual. Lower


Threshold

BSC6900

AMRULQUAFTLEN

AMR Filter Length for UL


Qual

BSC6900

AMRULQUALBADTRIG

AMR UL Qual. Bad Trig


Threshold

BSC6900

AMRULQUALBADUPLEV

AMR UL Qual. Bad


UpLEVDiff

BSC6900

AMRULSSHTHRED

AMR UL RX_LEV Upper


Threshold

BSC6900

AMRULSSLTHRED

AMR UL RX_LEV Lower


Threshold

BSC6900

AN19

MAX Retrans Reset Circle


BSC6900
Msg on A-I

AN4

MAX Reset Mesg


Retransmission on A-I

BSC6900

ANC_Max_Gain

ANC Max Gain

BSC6900

ANC_Switch

ANC Switch

BSC6900

ANC_Target_SNR

ANC Target SNR

BSC6900

ANGLE

RET Antenna Tilt Angle

BSC6900

ANI

Adjacent Node ID

BSC6900

ANI

Adjacent node ID

BSC6900

ANM

Alarm Name

BSC6900

ANR_Mode

ANR Mode

BSC6900

ANR_Noise_Reduction_Lev ANR Noise Reduction


el
Level

BSC6900

ANR_Noise_Target_Level

ANR Noise Target Level

BSC6900

ANR_Switch

ANR Switch

BSC6900

ANTAANGLE

Antenna Azimuth Angle

BSC6900

ANTENNALONG

GPS Antenna Delay

BSC6900

ANTENNAPOWERSWITCH

Antenna Power Supply


Switch

BSC6900

ANTIERRFLAG

E1T1 anti-error switch

BSC6900

AntiTheftAllow

Burglar Alarm Auto Clear


BSC6900
Permit

ANTNO

Antenna No.

BSC6900

ANTPASSNO

Sub-Location Group
Antenna Pass No.

BSC6900

ANTPASSNO

Antenna Pass No

BSC6900

AORB

Down TRX1 A or B

BSC6900

APN

A interface port No.

BSC6900

APP

Application type

BSC6900

APPTYPE

Application Type

BSC6900

AqmM

AQM N Update Interval

BSC6900

AqmMaxTh

AQM Maximum Threshold BSC6900

AqmMinTh

AQM Congestion
Threshold

BSC6900

AqmNinit

AQM Packet Discard


Initial Interval

BSC6900

AqmNLowerBound

AQM Packet Discard


BSC6900
Interval Lower Threshold

AqmNUpBound

AQM Packet Discard


BSC6900
Interval Upper Threshold

AqmSwitch

AQM Switch

BSC6900

AqmTarTh

AQM Target Threshold

BSC6900

AreaCode

Area Code

BSC6900

AREAFLAG

Area flag

BSC6900

AREAFLAG

Area flag

BSC6900

AREDISTHD

Abnormal Release
Threshold

BSC6900

ARELBASE

Abnormal Release
Statistic Base

BSC6900

ARELWTHD

Abnormal Warn
Threshold

BSC6900

ARPRETRY

ARP packet resend times BSC6900

ARPTIMEOUT

ARP packet timeout[100ms]

BSC6900

ASN

A interface slot No.

BSC6900

ASN

A interface slot No.

BSC6900

ASRN

A interface subrack No.

BSC6900

ASS

Event Type

BSC6900

ASS

Event Type

BSC6900

AssignBetterCellEn

Assigning Better Cell


Allowed

BSC6900

ASSLOADJUDGEEN

Assignment Cell Load


Judge Enable

BSC6900

ASSOLRXLEVOFFSET

Assign to Overlayer
RxLev Offset

BSC6900

ASSORXUCN

Associated RXU Board


CN

BSC6900

ASSORXUCN

Associated RXU Board


CN

BSC6900

ASSORXUSN

Associated RXU Board SN BSC6900

ASSORXUSN

Associated RXU Board SN BSC6900

ASSORXUSRN

Associated RXU Board


SRN

BSC6900

ASSORXUSRN

Associated RXU Board


SRN

BSC6900

ASSThres

Absolute Signal Strength


BSC6900
Threshold

ASSTIMER

T3107

BSC6900

AT1

T1

BSC6900

AT13

T13 -s

BSC6900

AT17

T17 -s

BSC6900

AT18

T18 -s

BSC6900

AT19

T19

BSC6900

AT20

T20

BSC6900

AT4

T4 -s

BSC6900

ATCBHOEN

Concentric Circles ATCB


HO Allowed

BSC6900

ATCBHYST

Distance Hysteresis
Between Boundaries

BSC6900

ATCBTHRED

Distance Between
Boundaries of Subcells

BSC6900

Ater8KSw

Switch of 8K on Ater

BSC6900

AterCongHRFlag

HR Allocation Flag

BSC6900

AterCongstRatio

Congestion Ratio on Ater


BSC6900
Resource

ATERIDX

Ater connection path


index

BSC6900

AterJamThreshold2StartLs

Ater Jam Rate for BSC


Local Switch

BSC6900

ATERMASK

Ater Mask

BSC6900

ATEROMLFLAG

Whether or not for OML

BSC6900

ATEROMLINX

Ater OML Index

BSC6900

ATERPIDX

Ater Connection Path


Index

BSC6900

ATERSLID

Ater Signaling Channel


ID

BSC6900

ATERTRANSMODE

Ater Interface Transfer


Mode

BSC6900

ATN

Antenna Tributary No.

BSC6900

ATSMASK

A interface timeslot
mask

BSC6900

ATT

Attach-detach Allowed

BSC6900

ATTENFACTOR1

Antenna Tributary 1
Factor

BSC6900

ATTENFACTOR2

Antenna Tributary 2
Factor

BSC6900

AUSTOP

Loop time[min]

BSC6900

AUSTOP

Test time[min]

BSC6900

AUTHMODE

Validate Mode

BSC6900

AUTHMODE

Validate mode

BSC6900

AUTHMODE

Validate mode

BSC6900

AUTHMODE

Authentication Mode

BSC6900

AUTHNAME

Validate User Name

BSC6900

AUTHNAME

Validate user name

BSC6900

AUTHNAME

Validate user name

BSC6900

AUTHPWD

Validate Password

BSC6900

AUTHPWD

Validate password

BSC6900

AUTHPWD

Validate password

BSC6900

AUTHTYPE

Validate Protocol Type

BSC6900

AUTHTYPE

Validate protocol type

BSC6900

AUTHTYPE

Validate protocol type

BSC6900

AUTO

Auto negotiation

BSC6900

AUTOADDSRCON

Add inter-subrack path


automatically

BSC6900

AUTOADJULTHHYSTF

Auto Adjust UL TH and


Hysteresis [F]

BSC6900

AUTOADJULTHHYSTH

Auto Adjust UL TH and


Hysteresis [H]

BSC6900

AutoGetBtsLogFlag

Support Auto Obtaining


of BTS Logs

BSC6900

AUTONEG

Automatic Negotiation
Mode

BSC6900

AUTOTYPE

Work Mode for Auto


Download Activation

BSC6900

AUTOULKSW

Auto Unlock Switch

BSC6900

AutoUnlockTime

Auto Unlock Time

BSC6900

AUTYPE

Administration unit type

BSC6900

AVer

A Interface Tag

BSC6900

AVOL

Alarm level

BSC6900

AVOL

Alarm VOL.

BSC6900

B1B2SDTHRD

B1B2 signal degraded


threshold

B1B2SFTHRD

B1B2 signal fail threshold BSC6900

B3SDTHRD

B3 signal degrade
threshold

BSC6900

B3SFTHRD

B3 signal fail threshold

BSC6900

BACK8KCLKSW1

Switch of backplane
LINE1

BSC6900

BACK8KCLKSW2

Switch of backplane
LINE2

BSC6900

BACKUPPATH

Path of Backup File

BSC6900

BackupPath

Backup Path

BSC6900

BSC6900

BADQUALDISCTHRES

Bad Quality
BSC6900
Disconnection Threshold

bAdvEstDlTbf

Support Advance
Downlink TBF
Establishment

BSC6900

BAKDEVTAB

BTS Interface Board Bar


Code 2

BSC6900

BAKIP

Backup port IP address

BSC6900

BAKMASK

Backup port mask

BSC6900

BAKPWRSAVMETHOD

Backup Power Saving


Method

BSC6900

BAKPWRSAVPOLICY

Backup Power Saving


Policy

BSC6900

BANDINDICATOR1900

High Band Indicator of


Cell 1900

BSC6900

BANDINDICATOR850

High Band Indicator of


Cell 850

BSC6900

BANDINDICATOR900

High Band Indicator of


Cell 900

BANTIME

Forbidden time after MAX


BSC6900
Times

BARCODLST

Cabinet Bar Code List

BSC6900

BASEBTSID

Reference BTS Index

BSC6900

BASETEMPERATURE

Temperature Basis for


Compensation

BSC6900

BASETEMPERATURE

Temperature Basis for


Compensation

BSC6900

BATTCAPACITY

Battery Capacity

BSC6900

BATTENABLEDIN

Battery Configuration
Enabled

BSC6900

BSC6900

BATTERYDISCHARGEDEPT
Battery Discharge Depth BSC6900
H

BATTTYPE

Battery Type

BSC6900

BBAPSRVPN

BBAP service listening


port No.

BSC6900

BBDIF

Up Down Balance Basic


Difference

BSC6900

BC

Battery Capcity

BSC6900

BCC

BCC

BSC6900

BCC

BCC

BSC6900

BCC

BCC

BSC6900

BCCH

BCCH FD

BSC6900

BCCHFREQ

Main BCCH Frequency

BSC6900

BCCHTRXHP

Frequency Hopping Mode


BSC6900
of BCCH TRX

BCCONGESTALMBOUND

BC Congestion Alarm
Threshold

BSC6900

BCCONGESTRESALMBOU
ND

BC Congestion Restore
Alarm Threshold

BSC6900

BCDSCP

DSCP of BG[QoS]

BSC6900

BCID

BC Identifier

BSC6900

BCLC

Battery Current Limiting


Coefficient

BSC6900

BCV

Boost-Charging Voltage

BSC6900

BE

Battery Configuration
Enabled

BSC6900

BEARP1PRIWEIGHT

BestEffort-ARP1 Priority
Weight

BSC6900

BEARP2PRIWEIGHT

BestEffort-ARP2 Priority
Weight

BSC6900

BEARP3PRIWEIGHT

BestEffort-ARP3 Priority
Weight

BSC6900

BEARTYPE

DSP bear type

BSC6900

BEATSENDINGDIS

Interval for Sending


Heartbeat

BSC6900

BEPPERIOD

Bep Period

BSC6900

BESTTDDCELLNUM

Best TDD Cell Number

BSC6900

BET3GHOEN

Better 3G Cell HO
Allowed

BSC6900

BETTERCELLHOEN

Better Cell Handover


Enable

BSC6900

BETTERCELLLASTTIME

Better Cell HO Valid Time BSC6900

BETTERCELLSTATTIME

Better Cell HO Watch


Time

BSC6900

BFDDETECTCOUNT

Detect multiplier of BFD


packet

BSC6900

BFDSN

BFD Session No.

BSC6900

BFRANGE

Up Down Balance
Floating Range

BHPREPOLICY

Switchback Policy of
BSC6900
Baseband FH Mutual Aid

BITOFFSET

In Frame Bit Offset [1/8


bit]

BKGARP1PRIWEIGHT

Background-ARP1 Priority
BSC6900
Weight

BKGARP2PRIWEIGHT

Background-ARP2 Priority
BSC6900
Weight

BKGARP3PRIWEIGHT

Background-ARP3 Priority
BSC6900
Weight

BLKFILTERSW

Alarm switch of blinking


filter

BSC6900

BLKPRD

Alarm blink threshold

BSC6900

BLKSTATPRD

Observing time window


of statistical alarm

BSC6900

BSC6900

BSC6900

BLKSTATSW

Switch of statistics
blinking alarm

BSC6900

BLOCKRETRY

Block Retry

BSC6900

BLOCKTIMER

Block Timer

BSC6900

BMPN

BM Port No

BSC6900

BMSN

BM Slot No

BSC6900

BMSRN

BM Subrack No

BSC6900

BMTCFCTimerLen

Timer Length of BM-TC


Flow Control

BSC6900

BORROWDEVIP

Borrow DevIP

BSC6900

BOXFLG

To Alarm Box Flag

BSC6900

BP1

Position of Break Point 1

BSC6900

BP2

Position of Break Point 2

BSC6900

BQHOEN

BQ HO Allowed

BSC6900

BQLASTTIME

BQ HO Valid Time

BSC6900

BQMARGIN

BQ HO Margin

BSC6900

BQSTATTIME

BQ HO Watch Time

BSC6900

BRDCLASS

Board Class

BSC6900

BRDCLASS

Board Class

BSC6900

BRDCLASS

Board Class

BSC6900

BRDCLASS

Board Class

BSC6900

BRDNO

Board No.

BSC6900

BRDNO

Board No.

BSC6900

BRDRXBW

Receive Bandwidth

BSC6900

BRDSWTYPE

BTS Board Software Type BSC6900

BRDTXBW

Forward Bandwidth

BSC6900

BRDTYPE

Board Type

BSC6900

BRDTYPE

Board Type

BSC6900

BRDTYPE

Board type.

BSC6900

BRDTYPE

Board type

BSC6900

BRDTYPE

Board type

BSC6900

BRDTYPE

Board type

BSC6900

BrdType

Board Type

BSC6900

BRDTYPE

Board Type

BSC6900

BREAKTIME

Ring II Wait Time Before


Switch

BSC6900

BROADCASTCONTENT

Broadcast Content

BSC6900

BROADCASTINTERVAL

Broadcast Interval

BSC6900

BS

Backup Style

BSC6900

BSAGBLKSRES

CCCH Blocks Reserved


for AGCH

BSC6900

BSCDPC

External BSC DPC

BSC6900

BSCDynSwitchTrxPAAllow

Allow Dynamic Shutdown


BSC6900
of TRX by BSC

BSCFLAG

BSC Flag

BSC6900

BSCGATEWAYIP

BSC GateWay IP

BSC6900

BSCGATHET

BSC Offset Information


Collection End Time

BSC6900

BSCGATHST

BSC Offset Information


Collection Start Time

BSC6900

BSCID

BSC ID

BSC6900

BSCIDX

BSC Index

BSC6900

BSCINCHPRD

BSC Fine Tuning Period

BSC6900

BSCIP

BSC IP

BSC6900

BSCIP

BSC IP

BSC6900

BscLsStartMode

Options for BSC Local


Switch

BSC6900

BSCNAME

External BSC Name

BSC6900

BSCPMA

Preemption Allowed

BSC6900

BSCPMAIRAHO

Preemption Allowed
During Intra-BSC
Handover

BSC6900

BSCPN

In-BSC Port No.

BSC6900

BSCPORT

BSC Port

BSC6900

BSCPRICLASS

eMLPP Multi-Priority
Classes Allowed

BSC6900

BSCQAD

Queue Allowed

BSC6900

BSCQADIRAHO

Queuing Allowed During


Intra-BSC Handover

BSC6900

BSCRESERVEDPARA1

Reserved parameter 1

BSC6900

BSCRESERVEDPARA10

Reserved parameter 10

BSC6900

BSCRESERVEDPARA11

Reserved parameter 11

BSC6900

BSCRESERVEDPARA12

Reserved parameter 12

BSC6900

BSCRESERVEDPARA13

Reserved parameter 13

BSC6900

BSCRESERVEDPARA14

Reserved parameter 14

BSC6900

BSCRESERVEDPARA15

Reserved parameter 15

BSC6900

BSCRESERVEDPARA16

Reserved parameter 16

BSC6900

BSCRESERVEDPARA17

Reserved parameter 17

BSC6900

BSCRESERVEDPARA18

Reserved parameter 18

BSC6900

BSCRESERVEDPARA19

Reserved parameter 19

BSC6900

BSCRESERVEDPARA2

Reserved parameter 2

BSC6900

BSCRESERVEDPARA20

Reserved parameter 20

BSC6900

BSCRESERVEDPARA21

Reserved parameter 21

BSC6900

BSCRESERVEDPARA22

Reserved parameter 22

BSC6900

BSCRESERVEDPARA23

Reserved parameter 23

BSC6900

BSCRESERVEDPARA24

Reserved parameter 24

BSC6900

BSCRESERVEDPARA25

Reserved parameter 25

BSC6900

BSCRESERVEDPARA26

Reserved parameter 26

BSC6900

BSCRESERVEDPARA27

Reserved parameter 27

BSC6900

BSCRESERVEDPARA28

Reserved parameter 28

BSC6900

BSCRESERVEDPARA29

Reserved parameter 29

BSC6900

BSCRESERVEDPARA3

Reserved parameter 3

BSC6900

BSCRESERVEDPARA4

Reserved parameter 4

BSC6900

BSCRESERVEDPARA5

Reserved parameter 5

BSC6900

BSCRESERVEDPARA6

Reserved parameter 6

BSC6900

BSCRESERVEDPARA7

Reserved parameter 7

BSC6900

BSCRESERVEDPARA8

Reserved parameter 8

BSC6900

BSCRESERVEDPARA9

Reserved parameter 9

BSC6900

BSCSN

In-BSC Slot No.

BSC6900

BSCSRN

In-BSC Subrack No.

BSC6900

BSCSUBTS

In-BSC Sub Timeslot No.

BSC6900

BSCSYMOFF

BSC Symbol Offset

BSC6900

BSCTID

ID of BSC in TC Pool

BSC6900

BSCTID

ID of a BSC in TC Pool

BSC6900

BSCTS

In-BSC Timeslot No.

BSC6900

BSCVMAX

BS_CV_MAX

BSC6900

BSMSPWRLEV

Transfer BTS/MS Power


Class

BSC6900

BSPAGBLKSRES

Number of PAGCH Blocks BSC6900

BSPAMFRAMS

Multi-Frames in a Cycle
on the Paging CH

BSPBCCHBLKS

Number of PBCCH Blocks BSC6900

BSPRACHBLKS

Number of PRACH Blocks BSC6900

BssLsGenMode

BSS Local Switching


General Strategy

BSC6900

BSC6900

BSSLSMSCCOOP

MSC-Collaborated BSS
Local Switching

BSC6900

BSSPAGINGCOORDINATIO
BSS Paging Co-ordination BSC6900
N

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board Type

BSC6900

BT

Board Type

BSC6900

BT

Board type

BSC6900

BT

Board Type

BSC6900

BT

Board Type

BSC6900

BT

Board Type

BSC6900

BT

Board Type

BSC6900

BT

Board Type

BSC6900

BT

Board Type

BSC6900

BTCFLAG

BM/TC config flag

BSC6900

BTCFLAG

BM/TC config flag

BSC6900

BTSadjust

Adjust Voltage

BSC6900

BTSBARCODE

BTS Bar Code

BSC6900

BTSCOMTYPE

BTS Communication Type BSC6900

BTSCOMTYPE

BTS Communication Type BSC6900

BTSDESC

BTS Description

BSC6900

BTSDETECTSWITCH

BTS Detect Switch

BSC6900

BTSID

Site Index

BSC6900

BTSID

BTS Index

BSC6900

BTSID

BTS Index

BSC6900

BTSIDCONBSC

Connect BSC BTS Index

BSC6900

BTSIDLST

BTS Index List

BSC6900

BTSIDTYPE

BTS Index Type

BSC6900

BTSIDTYPE

BTS Index Type

BSC6900

BTSIDX

Site Index Collect

BSC6900

BTSIP

BTS IP

BSC6900

BtsLsStartMode

Options for BTS Local


Switch

BSC6900

BTSMASK

Subnet Mask

BSC6900

BTSMESRPTPREPROC

MR.Preprocessing

BSC6900

BTSNAME

BTS Name

BSC6900

BTSNAMECONBSC

Connect BSC BTS Name

BSC6900

BTSNAMELST

BTS Name List

BSC6900

BTSPINGSWITCH

BTS Ping Switch

BSC6900

BTSPOWEROFFLOCKBCCH BTS Power-off Lock BCCH BSC6900

BTSPWRNUM

BTS PC Class

BSC6900

BTSSAICPCADJSWITCH

Switch for BTS


Supporting SAIC PC
Adjust

BSC6900

BTSSWVER

BTS Software Version

BSC6900

BTSTRCMPRATE

Transmission
Compression Ratio

BSC6900

BTSTYPE

BTS Type

BSC6900

BTSTYPE

BTS Type

BSC6900

BTSTYPE

BTS Type

BSC6900

BTSWTR

Time for Waiting to


Restore

BSC6900

BTTSTTYPE

BT Test Type

BSC6900

BTYPE

Battery Type

BSC6900

BUILDTIME

Ring II Try Rotating


Duration Time

BSC6900

BUNDLINGFLAG

Bundling Flag

BSC6900

BVCI

PTP BVC Identifier

BSC6900

BVCI

PTPBVC Identifier

BSC6900

BVCTF

BVC Flow Control Timer

BSC6900

BWADJ

Auto adjust bandwidth


switch

BSC6900

BWDCONGBW

Backward congestion
remain bandwidth

BSC6900

BWDCONGCLRBW

Backward congestion
clear remain bandwidth

BSC6900

BWDCONGCLRTH

Backward congestion
clear remain ratio

BSC6900

BWDCONGTH

Backward congestion
remain ratio

BSC6900

BWDOVLDCLRRSVBW

Backward overload
congestion clear remain
bandwidth

BSC6900

BWDOVLDCLRTH

Backward overload
congestion clear remain
ratio

BSC6900

BWDOVLDRSVBW

Backward overload
congestion remain
bandwidth

BSC6900

BWDOVLDTH

Backward overload
congestion remain ratio

BSC6900

BWDRESVHOTH

Backward handover
reserved ratio

BSC6900

BWDRSVHOBW

Backward handover
reserved bandwidth

BSC6900

BWMAXRATIO

Max bandwidth estimate


BSC6900
ratio [%]

BWMODE

Bandwidth Mode

BSC6900

BWRTPTH

Load Control algorithm


BandWidth THD[%]

BSC6900

BWTHD

Up Down Balance Alarm


Threshold

BSC6900

BYCELLTYPE

Cell Index Type

BSC6900

C31HYST

GPRS Cell Reselect


Hysteresis Applied to
C31 Criterion

BSC6900

C32QUAL

Exceptional Rule for


GPRS Reselect Offset

BSC6900

CABINETDESC

Cabinet Description

BSC6900

CABLST

Cabinet List

BSC6900

CABT

Is remote cabinet

BSC6900

CALLRESTABDIS

Call Reestablishment
Forbidden

BSC6900

CALVAL

Calibration Value

BSC6900

CANPC

PWRC

BSC6900

CAPCOVEROPTSWITCH

Capacity and Coverage


Optimize Switch

BSC6900

CARDFREATTR

Card Frequency Attribute BSC6900

CARRYFLAG

Carry Flag

BSC6900

CARRYT

The bearing type of the


logic port

BSC6900

CARRYT

Carry port type

BSC6900

CBA

Cell Bar Access

BSC6900

CBCINDEX

CBC INDEX

BSC6900

CBCIP

CBC IP

BSC6900

CBCITFPARA

CBC ITF Para

BSC6900

CBCPORT

CBC Port

BSC6900

CbNonMsgTimer

Cb No Message
Disconnection Timer

BSC6900

CBQ

Cell Bar Qualify

BSC6900

CBS

Consent burst size [Byte] BSC6900

CbShakeHandTimer

Cell Broadcast
Handshake Timer

BSC6900

CBSIGNLEN

Filter Length for SDCCH


CV_BEP

BSC6900

CBTRAFFLEN

Filter Length for TCH


CV_BEP

BSC6900

CC

CC

BSC6900

CCAEnableSta

Certificate Chain File


Enabled State

BSC6900

CCCHLOADINDPRD

CCCH Load Indication


Period

BSC6900

CCCHLOADTHRES

CCCH Load Threshold

BSC6900

CCDSCP

DSCP of CONV[QoS]

BSC6900

CCMINTERVAL

CCM Send Prid

BSC6900

CDRTTRYFBDTHRES

Cell Directed Retry


Forbidden Threshold

BSC6900

CELL1800OFF

1800 Reporting Offset

BSC6900

CELL1800THRED

1800 Reporting
Threshold

BSC6900

CELL2GBA1BCCH

2G NCELL BCCH

BSC6900

CELL2GBA1TAG

2GBA1 Input Tag

BSC6900

CELL2GBA2BCCH

2G NCELL BCCH

BSC6900

CELL2GBA2TAG

2GBA2 Input Tag

BSC6900

CELL8PSKPOWERLEVEL

Cell 8PSK Power


Attenuation Grade

BSC6900

CELL900OFF

900 Reporting Offset

BSC6900

CELL900THRED

900 Reporting Threshold BSC6900

CELLBARACCESS2

Cell Access Bar Switch

BSC6900

CELLCOVERAGETYPE

Cell Coverage Type

BSC6900

CELLEQUCHGVOL

Even Charging Voltage

BSC6900

CELLEQUCHGVOL

Even Charging Voltage

BSC6900

CELLFLOATCHGVOL

Float Charging Voltage

BSC6900

CELLFLOATCHGVOL

Float Charging Voltage

BSC6900

CELLID

Cell Index

BSC6900

CELLID

Cell Index

BSC6900

CELLID

Cell Index

BSC6900

CELLID

Cell Index

BSC6900

CELLID

Cell Index

BSC6900

CELLID

Cell Index

BSC6900

CELLIDLST

Cell List

BSC6900

CELLIDTYPE

Cell Index Type

BSC6900

CELLIDTYPE

Cell Index Type

BSC6900

CELLIDTYPE

Cell Index Type

BSC6900

CELLINEXTP

Cell Inner/Extra Property BSC6900

CELLLAYER

Layer of the cell

BSC6900

CELLLIST

Cell Index List

BSC6900

CellListOptionSend

Cell List Send Flag in ASS


BSC6900
CMP

CELLMAXSD

Cell SDCCH Channel


Maximum

BSC6900

CELLNAME

Cell Name

BSC6900

CELLNAME

Cell Name

BSC6900

CELLNAME

Cell Name

BSC6900

CELLNAMELIST

Cell Name List

BSC6900

CELLOPPWRGRP

Cell Operator Power


Group

BSC6900

CELLOVERCVGRXLEVDLTH

Cell Over Coverage DL


RxLev Threshold

BSC6900

CELLOVERCVGTALTH

Cell Over Coverage TA


Threshold

BSC6900

CELLPAGINGOVERLOADC
OUNTER

Cell Paging Overload


Threshold

BSC6900

CELLPWROFFEN

Battery Power-off
Allowed State

BSC6900

CELLPWROFFVOL

Battery Power-off Voltage BSC6900

CELLRESELSTRATEGY

2G/3G Cell Reselection


Strategy

BSC6900

CELLRXQUALWORSENRATI Cell Rx Quality Worsen


OTHRSH
Ratio Threshold

BSC6900

CELLSCENARIO

BSC6900

Cell Scenario

CELLSELECTAFTERCALLRE Select 3G Cell After Call


L
Release

BSC6900

CELLTEMP1ALARMH

High Temp Alarm


Assembled Battery1

BSC6900

CELLTEMP1ALARML

Low Temp Alarm


Assembled Battery1

BSC6900

CELLTEMP1THRESHOLDH

Upper Assembled
Battery 1 Temp

BSC6900

CELLTEMP1THRESHOLDL

Lower Assembled
Battery1 TEMP Measure

BSC6900

Battery Temperature
CELLTEMPCOMPENABLED Compensated Configure
Enabled

BSC6900

CELLWEAKCVGRXLEVDLT
H

BSC6900

Cell Weak Coverage DL


RxLev Threshold

CELLWEAKCVGTALTH

Cell Weak Coverage TA


Threshold

BSC6900

CENDTHD

Congestion End
Threshold

BSC6900

CertChain

Certificate Chain File


Name

BSC6900

CFGFLAG

Carry Flag

BSC6900

CFGFLAG

Board Parameter
Configuration Enabled

BSC6900

CFGMODE

BTS Configuration Mode

BSC6900

CFGSW

Configure switch

BSC6900

CFLAG

Board Parameter
Configuration Enabled

BSC6900

CFLAG

Board Parameter
Configuration Enabled

BSC6900

CFM

Confirm Password

BSC6900

CG

Command Group

BSC6900

CG

Command Group

BSC6900

CGET

Congestion End
Threshold

BSC6900

CGET

Congestion End
Threshold

BSC6900

CGIRACSWITCH

CGI and RAC Plan Switch BSC6900

CGN

Cabinet Group No.

BSC6900

CGN

Command Group Name

BSC6900

CGST

Congestion Start
Threshold

BSC6900

CGST

Congestion Start
Threshold

BSC6900

CGST

Congestion Start
Threshold

BSC6900

CHAINNCELLTYPE

Chain Neighbour Cell


Type

BSC6900

CHAINTORING

Combine Type

BSC6900

CHALLOCSTRATEGY

Channel Allocate
Strategy

BSC6900

CHANFAULTALMPDCHTH

PDCH Available
Threshold of Channel
Failure

BSC6900

CHANFAULTALMSWITCH

Monitoring Alarm Switch


BSC6900
for Channel Failure

CHANFAULTALMTCHTH

TCH Available Threshold


of Channel Failure

BSC6900

CHANID

Chan ID

BSC6900

CHANINTERMESALLOW

Active CH Interf.
Meas.Allowed

BSC6900

CHANNELRATECODE

Channel Rate Type


Decode Expand

BSC6900

CHANPDOUTTIME

PDCH Out-ofSynchronization Period

BSC6900

CHECKCOUNT

Ping Check Timeout


Counts

BSC6900

CheckingBTSConnection

Auto Check of BTS


Connection Port

BSC6900

ChkModA

ANT_A ALD Current


Detection Mode

BSC6900

ChkModB

ANT_B ALD Current


Detection Mode

BSC6900

CHKN

Check Index

BSC6900

CHKN

Check Index

BSC6900

CHKOFFTIMES

Check Times for Off

BSC6900

CHKONTIMES

Check Times for On

BSC6900

CHKSUMRX

Calculate checksum
when receive message

BSC6900

CHKSUMTX

Calculate checksum
when send message

BSC6900

CHKSUMTYPE

Checksum arithmetic

BSC6900

CHKTYPE

Check type

BSC6900

CHLDURATH

Duration<hour>

BSC6900

CHNNO

Channel No.

BSC6900

CHNNO

Channel No.

BSC6900

CHNO

Channel No.

BSC6900

CHNTSTTYPE

Channel Test Type

BSC6900

CHNTYPE

Channel Type

BSC6900

ChosenChInAssCmp

ChosenCh Send Flag in


ASS CMP

BSC6900

ChosenChInHoPerform

ChosenCh Send Flag in


HO Perform

BSC6900

ChosenChInHoReqAck

ChosenCh Send Flag in


HO REQ ACK

BSC6900

ChosenEncrypAlgInCiphC ChosenEncrypAlg Send


mp
Flag in Cipher CMP

BSC6900

ChosenEncrypAlgInHoPerf ChosenEncrypAlg Send


orm
Flag in HO Perform

BSC6900

ChosenEncrypAloInAssCm ChosenEncrypAlg Send


p
Flag in ASS CMP

BSC6900

ChosenEncrypAloInHoReq ChosenEncrypAlg Send


Ack
Flag in HO REQ ACK

BSC6900

CHPWRINSUFFALLOWED

Channel Assign Allow for


BSC6900
Insuff Power

CHRCOLLECTSWITCH

PS CHR Collect Switch

BSC6900

CHREQCSMAXMSGNUMIN Max CS CHAN REQ Num


PERIOD
in Period

BSC6900

CHREQPSAVGMSGNUMINP Average PS CHAN REQ


ERIOD
Num

BSC6900

CHREQSTATPERIOD

CHAN REQ Statistical


Period

BSC6900

CHTYPE

Channel Type

BSC6900

CI

Cell CI

BSC6900

CI1

Cell CI

BSC6900

CIC

CIC

BSC6900

CIC

CIC

BSC6900

CicDMuteDifCnt

Number of Different
Frames in CIC One-Way
Mute Detection

BSC6900

CicDMutePeriod

CIC Downlink One-Way


Mute Detection Period

BSC6900

CicDMuteSwitch

CIC Downlink One-Way


Mute Detection Switch

BSC6900

CicDMuteThre

CIC Downlink One-Way


Mute Detection
Threshold

BSC6900

CicDMuteTime

CIC Downlink One-Way


BSC6900
Mute Detection Duration

CicPoolInAssFail

CIC Pool Send Flag in


ASS Fail

CicPoolInHoFail

CIC Pool Send Flag in HO


BSC6900
Fail

CicPoolListInAssFail

CIC Pool List Send Flag in


BSC6900
ASS Fail

CicPoolListInHoFail

CIC Pool List Send Flag in


BSC6900
HO Fail

BSC6900

CicPoolSendFlagInAssCmp

CIC Pool Send Flag in


ASS CMP

CicPoolSendFlagInHoAck

CIC Pool Send Flag in HO


BSC6900
REQ ACK

CIR

Bandwidth [64kbps]

BSC6900

CIRESTVALUE

C/I Estimate Value

BSC6900

CIUSLOTNO

Slot No.

BSC6900

CIUSUBRACKNO

Subrack No.

BSC6900

CLASS11DTM

Support Class11 DTM

BSC6900

CLASSMARKQUERY

Classmark Enquiry With


3G Request

BSC6900

CLEARTHD

Error clear threshold

BSC6900

CLKMOD

Clock Mode

BSC6900

CLKPRTTYPE

Clock Protocol Type

BSC6900

CLKTYPE

Clock board type

BSC6900

BSC6900

ClkType

Clock Type

BSC6900

ClrDelay

Clear Command Delay


Time

BSC6900

CLRFLG

Alarm Cleared Flag

BSC6900

ClrInterval

Clear Command Time


Interval

BSC6900

CMD

Command Name

BSC6900

CMD

Command Name

BSC6900

CMDSEQ

Command Sequence

BSC6900

CN

Cabinet No.

BSC6900

CN

Cabinet No.

BSC6900

CN

Cabinet No.

BSC6900

CN

Port Cabinet No.

BSC6900

CN

Cabinet No.

BSC6900

CN

Cabinet No.

BSC6900

CNFAULTDELAY

CN Fault Delay

BSC6900

CNID

MSC ID

BSC6900

CNID

SGSN Node ID

BSC6900

CNNODEIDX

CN Node Index

BSC6900

CNOPERATORINDEX

Operator Index

BSC6900

CNSTATEPOLICYFORGROU CN State Policy For


P
Group

BSC6900

CNT

Records to Return

BSC6900

CNT

Cabinet Type

BSC6900

CNT

Cabinet Type

BSC6900

CNTL

Counts Limit

BSC6900

CNTRISTHRD

Upper count threshold of


BSC6900
raised fault

CNTSTLTHRD

Lower count threshold of


BSC6900
raised fault

COBSCMSCADJEN

Co-BSC/MSC Adj

BSC6900

CODE

Code

BSC6900

COLDSET

Refrigeration Equipment BSC6900

COLTYPE

Collection Type

BSC6900

COMBINERLOSS

Combiner Loss

BSC6900

COMMACC

Common Access Control


Class

BSC6900

Complicacy

Password Complexity

BSC6900

COMPRS

BTS Transfer
Compression Rate

BSC6900

COMSC

Co-MSC

BSC6900

CONBSCBTSIDTYPE

Connect BSC BTS Index


Type

BSC6900

CONGCLRTHD0

Recover threshold of
queue 0 [ms]

BSC6900

CONGCLRTHD1

Recover threshold of
queue 1 [ms]

BSC6900

CONGCLRTHD2

Recover threshold of
queue 2 [ms]

BSC6900

CONGCLRTHD3

Recover threshold of
queue 3 [ms]

BSC6900

CONGCLRTHD4

Recover threshold of
queue 4 [ms]

BSC6900

CONGCLRTHD5

Recover threshold of
queue 5 [ms]

BSC6900

CONGTHD0

Congestion threshold of
queue 0 [ms]

BSC6900

CONGTHD1

Congestion threshold of
queue 1 [ms]

BSC6900

CONGTHD2

Congestion threshold of
queue 2 [ms]

BSC6900

CONGTHD3

Congestion threshold of
queue 3 [ms]

BSC6900

CONGTHD4

Congestion threshold of
queue 4 [ms]

BSC6900

CONGTHD5

Congestion threshold of
queue 5 [ms]

BSC6900

CONHOEN

Concentric Circles HO
Allowed

BSC6900

CONNECTPORTNO

Connect Port No.

BSC6900

CONNPWR

Connect power
monitoring board

BSC6900

CONNTYPE

Connection Type

BSC6900

CONNTYPE

Connection Type

BSC6900

CONTHOMININTV

Min Interval for


Consecutive HOs

BSC6900

CONTINTV

Interval for Consecutive


HO Jud.

BSC6900

CONTPING

Continue ping or not

BSC6900

Count

Send PKT Count

BSC6900

CPRIDURATS

Duration Second

BSC6900

CPS

Allow Dynamic Shutdown


BSC6900
of TRX

CPUN

CPU NO

BSC6900

CRC4CHK

CRC4 Check Switch

BSC6900

CRH

Cell Reselect Hysteresis


Parameters

BSC6900

CRL

Certificate Revocation
List File Name

BSC6900

CRLEnableSta

Certificate Revocation
List File State

BSC6900

CRMSGRESENDINT

Channel Release Resend


BSC6900
Interval

CRMSGRESENDNUM

Channel Release Resend


BSC6900
Number

CRO

Cell Reselect Offset

BSC6900

CROCALTMTHRD

Cross Call Detect Time


Threshold

BSC6900

CROSSIPFLAG

Cross IP address
available flag

BSC6900

CSADDTINFO

CHR Supplementary Info


BSC6900
Output Control

CSBQTHR

Bad Speech Quality Rate


BSC6900
Threshold

CSCHRMR

CHR MR Output

BSC6900

CSCLTERMABNORM

Abnormal Call End


Output Control

BSC6900

CSDATADL

GSM CS data service


downlink factor

BSC6900

CSDATAPATH

CS data path

BSC6900

CSDATAPRI

CS data priority

BSC6900

CSDATAUL

GSM CS data service


uplink factor

BSC6900

CSDSP

CS Data Service PRI

BSC6900

CSHOINFO

CHR Handover
Information Output

BSC6900

CSMRBFCLR

Output MR Before Call


Release

BSC6900

CSMRBFHO

Output MR Before
Handover

BSC6900

CSOUTMODE

CHR Output Mode

BSC6900

CSOUTRANGE

CHR Output Range

BSC6900

CSRCDSW

CHR Function Switch

BSC6900

CSSIGINFO

CHR Signaling Output

BSC6900

CSTARTTHD

Congestion Start
Threshold

BSC6900

CSTRAFTYPE

Service Type of CHR


Output

BSC6900

CSVOICEDL

GSM CS voice service


downlink factor

BSC6900

CSVOICEINFO

CHR Speech Information BSC6900

CSVOICEPATH

CS voice path

BSC6900

CSVOICEPRI

CS voice priority

BSC6900

CSVOICEUL

GSM CS voice service


uplink factor

BSC6900

CSVSP

CS Voice Service PRI

BSC6900

CSW

Self-healing Switch for


Ethernet Adapter Traffic
Monitoring

BSC6900

CT1

Timer alignment ready

BSC6900

CT2

Timer not aligned

BSC6900

CT3

Timer aligned

BSC6900

CT4E

Timer emergency
proving

BSC6900

CT4N

Timer normal proving

BSC6900

CT5

Timer sending SIB

BSC6900

CT6

Timer remote congestion BSC6900

CT7

Timer excessive delay of


BSC6900
acknowledgement

CT9

Timer interval of
resending FISU

BSC6900

CTHD

Critical threshold

BSC6900

CTHD

Critical threshold

BSC6900

CTRBSCDPC

Control BSC DPC

BSC6900

CTRLACKTYPE

Control Acknowledge
Type

BSC6900

CTRLFLAG

Control Flag

BSC6900

CTRLPORTCN

Control Port Cabinet No.

BSC6900

CTRLPORTNO

Control Port No.

BSC6900

CTRLPORTSN

Control Port Slot No.

BSC6900

CTRLPORTSRN

Control Port Subrack No. BSC6900

CTRLSLOT

Slot No.

BSC6900

CTRLSN

Control Plane Slot No.

BSC6900

CTRLSRN

Control Plane Subrack


No.

BSC6900

CTRLSW

CM Control Enable
Switch

CurChannelInHoRqd

HO_RQD Current Channel BSC6900

CVer

C-Version No.

BSC6900

CYCLE

Period of New File


Generation[min]

BSC6900

DATAFILE

Data file

BSC6900

DATAQUAFLTLEN

Filter Length for TCH


Qual

BSC6900

DATASTRFLTLEN

Filter Length for TCH


Level

BSC6900

DATATRAFFSET

Data Service Allowed

BSC6900

DATE

Date

BSC6900

DATE

Date Limit

BSC6900

DateRangeIndex

Prohib DynShutdown TRX


BSC6900
DateRangeIdx

Day

Day

BSC6900

DBD

Dead Band

BSC6900

BSC6900

DBFREQBCCHIUO

BCCH IUO of Double


Frequency Cell

BSC6900

DBLFREQADJCID

Same Group Cell Index

BSC6900

DBLFREQADJCNAME

Same Group Cell Name

BSC6900

DBLFREQADJIDTYPE

Same Group Cell Index


Type

BSC6900

DCLACN

DC Low Voltage Alarm


Cabinet No.

BSC6900

DCLAPN

DC Low Voltage Alarm


Port No.

BSC6900

DCLASN

DC Low Voltage Alarm


Slot No.

BSC6900

DCLASRN

DC Low Voltage Alarm


Subrack No.

BSC6900

DCVLTHD

DC Voltage Lower
Threshold

BSC6900

DCVOLALARMH

DC Overvoltage Alarm
Threshold

BSC6900

DCVOLALARML

DC Under Voltage Alarm


Threshold

BSC6900

DCVUTHD

DC Voltage Upper
Threshold

BSC6900

DefaultDynPdchPreTranNu Number of Dynamic


m
Channel Pre-Converted

BSC6900

DELAYSENDRFCHREL

T3111

BSC6900

DENO

Destination entity No.

BSC6900

DESC

Description

BSC6900

DESTEALSET

Anti-theft Equipment

BSC6900

DESTIP

Destination IP address

BSC6900

DESTIP

Destination IP address

BSC6900

DESTIP

Destination IP address

BSC6900

DESTMEPID

RMEP ID

BSC6900

DESTNODE

Transport Link Type

BSC6900

DESTNODE

Dest Node Type

BSC6900

DESTSN

Peer Slot No.

BSC6900

DESTSRN

Peer Subrack No.

BSC6900

DESTSSN

Peer Subsystem No.

BSC6900

DESTTRXID

Destination Main BCCH


TRX ID

BSC6900

DETECTFRAMEPERIOD

Period of Mute Detect


Class2 TRAU Frame

BSC6900

DETECTMULT

Detect Period

BSC6900

DETECTSWITCH

Switch for Abis Timeslot


Detection

BSC6900

DEVICENAME

Device Name

BSC6900

DEVICENO

Device No.

BSC6900

DEVIP

Borrowed device IP
address

BSC6900

DEVTYPE

Device IP Address Type

BSC6900

DF

DL UARFCN

BSC6900

DFCBSN

DFCB Board SN

BSC6900

DFCBSRN

DFCB Board SRN

BSC6900

DFDPC

Default DPC

BSC6900

DFTPORTSWT

The Type of FTP Server


Command Port

BSC6900

DGPSPERIOD

DGPS data report


period[min]

BSC6900

DHCPRLYGATEWAYIP

DHCP Relay Gateway IP


Address

BSC6900

DHCPRLYID

DHCP Relay ID

BSC6900

DIESELENGINESAVESWITC Diesel Engine Save


H
Switch

BSC6900

DIFFBANDSDCCHUSINGO Different Band SDCCH


PTIMIZE
Using Optimize

BSC6900

DINM

Date in Month

BSC6900

DINW

Date in Week

BSC6900

DIR

Directory

BSC6900

DIR

File Directory

BSC6900

DirectedRetryAssFailSend Directed Retry AssFail


Enable
Send Enable

BSC6900

DIRECTRYEN

BSC6900

Directed Retry

DIRMAGANSITEFLAG

Directly Magnifier BTS


Flag

BSC6900

DisconnectHandoverProte Disconnect Handover


ctTimer
Protect Timer

BSC6900

DIVERSITY

Diversity

BSC6900

DIVERT16QAMDELAY

Diversity Transmitter
16QAM Delay

BSC6900

DIVERT32QAMDELAY

Diversity Transmitter
32QAM Delay

BSC6900

DIVERT8PSKDELAY

Diversity Transmitter
8PSK Delay

BSC6900

DivSwitch

Four Diversity Receiver

BSC6900

DLADJPRD

PwrCtrlDLAdjPeriod

BSC6900

DLAFSREXQUALHIGHTHR
DLAFSRexQualHighThred BSC6900
ED

DLAFSREXQUALLOWTHRE
DLAFSRexQualLowThred BSC6900
D

DLAHSREXQUALHIGHTHR
DLAHSRexQualHighThred BSC6900
ED

DLAHSREXQUALLOWTHR
ED

DLAHSRexQualLowThred BSC6900

DLCI

The Identifier of Data


Link Connection

BSC6900

DLCOEFFICIENTTSRAPIDA Fast DL Priority Decision


DJ
Threshold

BSC6900

DLDCSPT

Support Downlink DualCarrier

BSC6900

DLEDGETHRES

Edge HO DL RX_LEV
Threshold

BSC6900

DLFILTADJFACTOR

III DL Filter Adjust Factor

BSC6900

DLFSREXQUALHIGHTHRE
D

DLFSRexQualHighThred

DLFSREXQUALLOWTHRED DLFSRexQualLowThred

DlGprsTbfExpandOp

Downlink GPRS TBF


Window Expansion
Optimization

BSC6900

BSC6900

BSC6900

DLHSREXQUALHIGHTHRE
DLHSRexQualHighThred
D

BSC6900

DLHSREXQUALLOWTHRE
D

BSC6900

DLHSRexQualLowThred

DLHYSTF1

AMR DL Coding Rate


adj.hyst1[F]

BSC6900

DLHYSTF2

AMR DL Coding Rate


adj.hyst2[F]

BSC6900

DLHYSTF3

AMR DL Coding Rate


adj.hyst3[F]

BSC6900

DLHYSTH1

AMR DL Coding Rate


adj.hyst1[H]

BSC6900

DLHYSTH2

AMR DL Coding Rate


adj.hyst2[H]

BSC6900

DLHYSTH3

AMR DL Coding Rate


adj.hyst3[H]

BSC6900

DLHYSTWB1

AMR DL Coding Rate


adj.hyst1[WB]

BSC6900

DLHYSTWB2

AMR DL Coding Rate


adj.hyst2[WB]

BSC6900

DLINTERFLEVLIMIT

Interf.of DL Level
Threshold

BSC6900

DLINTERFQUALLIMIT

Interf.of DL
Qual.Threshold

DlLdrThrd2GCell

2G Cell DL Basic Congest


BSC6900
Thred

DLLEVFILTLEN

Filter Length for DL


RX_LEV

DLLTFERLOWTH

Downlink Long-term FER


BSC6900
Lower Threshold

DLLTFERTGT

Downlink Long-term FER


BSC6900
Target

DLLTFERUPTH

Downlink Long-term FER


BSC6900
Upper Threshold

DLLTTHADJFA

Downlink Threshold
Adjust Factor

BSC6900

BSC6900

BSC6900

DLMAXDOWNSTEP

DLMAXDownStep

BSC6900

DLMAXUPSTEP

DLMAXUpStep

BSC6900

DlOlcThrd2GCell

2G Cell DL Overload
Congest Thred

BSC6900

DLPREDLEND

DL MR. Number
Predicted

BSC6900

DLQHIGHTHRED

DL Qual. Upper
Threshold

BSC6900

DLQLOWTHRED

DL Qual. Lower
Threshold

BSC6900

DLQUAFILTLEN

Filter Length for DL Qual. BSC6900

DLQUALBADTRIG

DL Qual. Bad Trig


Threshold

BSC6900

DLQUALBADUPLEV

DL Qual. Bad UpLEVDiff

BSC6900

DLQUALIMIT

DL Qual. Threshold

BSC6900

DLQUALIMITAMRFR

DL Qual. Limit for AMR


FR

BSC6900

DLQUALIMITAMRHR

DL Qual. Limit for AMR


HR

BSC6900

DLREXLEVADJFCTR

DLRexLevAdjustFactor

BSC6900

DLREXLEVEXPFLTLEN

DLRexLevExponentFilterL
BSC6900
en

DLREXLEVHIGHTHRED

DLRexLevHighThred

BSC6900

DLREXLEVLOWTHRED

DLRexLevLowthred

BSC6900

DLREXLEVSLDWINDOW

DLRexLevSlideWindow

BSC6900

DLREXQUALADJFCTR

DLRexQualAdjustFactor

BSC6900

DLREXQUALEXPFLTLEN

DLRexQualExponentFilter
BSC6900
Len

DLREXQUALSLDWINDOW DLRexQualSlideWindow

BSC6900

DLRXLEVPROTECTFACTOR

III DL RexLev Protect


Factor

BSC6900

DLRXQUALPROTECTFACT
OR

III DL RexQual Protect


Factor

BSC6900

DLSSHIGHTHRED

DL RX_LEV Upper
Threshold

BSC6900

DLSSLOWTHRED

DL RX_LEV Lower
Threshold

BSC6900

DLTBFESTDELAY

Downlink TBF
Establishment Delay

BSC6900

DLTESTRESENDINT

Download Test Resend


Interval

BSC6900

DLTESTRESENDNUM

Download Test Resend


Number

BSC6900

DLTHF1

AMR DL Coding Rate


adj.th1[F]

BSC6900

DLTHF2

AMR DL Coding Rate


adj.th2[F]

BSC6900

DLTHF3

AMR DL Coding Rate


adj.th3[F]

BSC6900

DLTHH1

AMR DL Coding Rate


adj.th1[H]

BSC6900

DLTHH2

AMR DL Coding Rate


adj.th2[H]

BSC6900

DLTHH3

AMR DL Coding Rate


adj.th3[H]

BSC6900

DLTHWB1

AMR DL Coding Rate


adj.th1[WB]

BSC6900

DLTHWB2

AMR DL Coding Rate


adj.th2[WB]

BSC6900

DMDUA

Down MDU A

BSC6900

DMDUB

Down MDU B

BSC6900

DN

Domain

BSC6900

DNDEFAULTCS

Downlink Default CS
Type

BSC6900

DNDEFAULTMCS

Downlink Default MCS


Type

BSC6900

DNE2ADEFAULTMCS

Downlink EGPRS2-A
Default MCS Type

BSC6900

DNE2AFIXMCS

Downlink EGPRS2-A
Fixed MCS Type

BSC6900

DNFIXCS

Downlink Fixed CS Type

BSC6900

DNFIXMCS

Downlink Fixed MCS Type BSC6900

DNPCEN

DL PC Allowed

DNSENDSMDIS

Short Message Downlink


BSC6900
Disabled

BSC6900

DNTBFRELDELAY

Release Delay of
Downlink TBF

BSC6900

DNTHDCSDEGRADE1

Downlink TBF Threshold


from CS2 to CS1

BSC6900

DNTHDCSDEGRADE2

Downlink TBF Threshold


from CS3 to CS2

BSC6900

DNTHDCSDEGRADE3

Downlink TBF Threshold


from CS4 to CS3

BSC6900

DNTHDCSUPGRADE1

Downlink TBF Threshold


from CS1 to CS2

BSC6900

DNTHDCSUPGRADE2

Downlink TBF Threshold


from CS2 to CS3

BSC6900

DNTHDCSUPGRADE3

Downlink TBF Threshold


from CS3 to CS4

BSC6900

DOOR_ENGINE_MASK

Enable Door Status


Alarm Reporting

BSC6900

DOUBLEANTENNAGAIN

Double Antenna Gain

BSC6900

DPC

DSP code[Whole
Number]

BSC6900

DPCDNF

DSP code[Divided
Number]

BSC6900

DPCGIDX

DPC Group Index

BSC6900

DPCGIDX

DPC Group Index

BSC6900

DPCGIDX

DPC Group Index

BSC6900

DPCT

DSP type

BSC6900

DPX

DSP index

BSC6900

DPX

DPX

BSC6900

DRHOLEVRANGE

Directed Retry Handover


BSC6900
Level Range

DROPCTRLABISCONNFAIL

Drop Optimize ABIS Link


BSC6900
Failure

DROPCTRLCONNFAILHOA Drop Optimize Conn


CCFAIL
Fail[HO access fail]

DROPCTRLCONNFAILOM

Drop Optimize Conn


Fail[OM intervention]

BSC6900

BSC6900

DROPCTRLCONNFAILOTHE Drop Optimize Conn


R
Fail[other]

BSC6900

DROPCTRLCONNFAILRLFAI Drop Optimize Conn


L
Fail[radio link fail]

BSC6900

DROPCTRLCONNFAILRRN
OTAVL

Drop Optimize Conn


Fail[resource not
available]

BSC6900

DROPCTRLEQUIPFAIL

Drop Optimize
Equipment Failure

BSC6900

Drop Optimize Err


DROPCTRLERRINDDMRSP Ind[unsolicited DM
response]

BSC6900

DROPCTRLERRINDSEQER Drop Optimize Err


R
Ind[sequence error]

BSC6900

DROPCTRLERRINDT200

Drop Optimize Err


Ind[T200 timeout]

BSC6900

DROPCTRLFORCHOFAIL

Drop Optimize Forced


Handover Failure

BSC6900

DROPCTRLINBSCHO

Drop Optimize Into-BSC


Handover Timeout

BSC6900

DROPCTRLINTRABSCOUT
HO

Drop Optimize Intra-BSC


BSC6900
Handover Timeout

DROPCTRLINTRACELLHO

Drop Optimize Intra-Cell


Handover Timeout

DROPCTRLNOMR

Drop Optimize No MR for


BSC6900
Long Time

DROPCTRLOUTBSCHOT8

Drop Optimize Out-BSC


Handover Timeout

BSC6900

DROPCTRLRELIND

Drop Optimize Release


Indication

BSC6900

DROPCTRLRESCHK

Drop Optimize Resource


Check

BSC6900

DROPPKTTHD0

Packet discard threshold


BSC6900
of queue 0 [ms]

DROPPKTTHD1

Packet discard threshold


BSC6900
of queue 1 [ms]

BSC6900

DROPPKTTHD2

Packet discard threshold


BSC6900
of queue 2 [ms]

DROPPKTTHD3

Packet discard threshold


BSC6900
of queue 3 [ms]

DROPPKTTHD4

Packet discard threshold


BSC6900
of queue 4 [ms]

DROPPKTTHD5

Packet discard threshold


BSC6900
of queue 5 [ms]

DROPPWRINTERVAL

Drop Power Time


Interval[T3]

BSC6900

DROPPWRSTARTTIME

Drop Power Start


Time[T1]

BSC6900

DROPPWRSTEP

Drop Power Step

BSC6900

DRXEN

SMCBC DRX

BSC6900

DRXTIMERMAX

Max. Duration of DRX

BSC6900

DRYSET

Dehumidification
Equipment

BSC6900

DS1

E1T1 port No.

BSC6900

DS1

E1T1 port No.

BSC6900

DSCP

Differentiated Service
Codepoint

BSC6900

DSCP

Differentiated services
code point

BSC6900

DSCP

Differentiated Service
Codepoint

BSC6900

DSCP

DSCP

BSC6900

DSPKIFFOFFTIMER

DSP Kickoff Timer

BSC6900

DSPN

DSP No.

BSC6900

DSPN

DSP No.

BSC6900

DSPN

DSP No.

BSC6900

DSPN

DSP No.

BSC6900

DSPNO

DSP No.

BSC6900

DSPRECOVERTIMER

DSP Recover Timer

BSC6900

DST

DaylightSave

BSC6900

DSTF

Destination File Name

BSC6900

DSTIP

Destination IP Address

BSC6900

DSTIP

Destination IP Address

BSC6900

DSTIP

Destination IP address

BSC6900

DSTMASK

Destination Address
Mask

BSC6900

DSTMASK

Destination address
mask

BSC6900

DSTPORTNO

Destination port No.

BSC6900

DSTTSMASK

Destination timeslot
mask

BSC6900

DTLOADTHRED

Directed Retry Load


Access Threshold

BSC6900

DTRTYPE

DRX Type

BSC6900

DTRX

Down Link No.

BSC6900

DTRX

Down Link No.

BSC6900

DTRXPN

Down TRX Board Pass


No.

BSC6900

DTRXPN

Down TRX Board Pass


No.

BSC6900

DTRXSN

Down TRX Slot No.

BSC6900

DTRXSN

Down TRX Slot No.

BSC6900

DTRXSRN

Down TRX Subrack No.

BSC6900

DTRXSRN

Down TRX Subrack No.

BSC6900

DUMMYBITRANDSWITCH

Dummy Bit
Randomization Switch

BSC6900

DUPLEX

Duplex Mode

BSC6900

DURATH

Duration<Hour>

BSC6900

DURATH

Duration Hour

BSC6900

DURATM

Duration<minute>

BSC6900

DURATS

Duration<s>

BSC6900

DWNDYNCHNTRANLEV

Downlink Multiplex
Threshold of Dynamic
Channel Conversion

BSC6900

DWNINTEN

DL Signal Strength Limit

BSC6900

DXXINDEX

DXX Index

BSC6900

DXXINDEX

Up DXX Index

BSC6900

DXXPN

Up DXX Port No.

BSC6900

DYNCHFREETM

Timer of Releasing Idle


Dynamic Channel

BSC6900

DYNCHNPREEMPTLEV

Level of Preempting
Dynamic Channel

DYNCHTRANRESLEV

Reservation Threshold of
Dynamic Channel
BSC6900
Conversion

DYNOpenTrxPower

Allow Dynamic Shutdown


BSC6900
of TRX

DYNPBTSUPPORTED

Dynamic Transmission
Div Supported

BSC6900

E1DURAT

Duration

BSC6900

E1PORT

Port No.

BSC6900

E1PORTNOINBTSCONBSC

E1 Port No Connect To
BSC

BSC6900

E1SLCTTMU

Transmission Board Type BSC6900

E1T1PN

E1/T1 Port No.

BSC6900

E1T1PN

E1/T1 port No.

BSC6900

BSC6900

E1T1PORTNO

Backboard E1/T1 Port No. BSC6900

E1T1TYPE

E1/T1 Type

BSC6900

ECHOIP

Check IP address

BSC6900

ECNOOFF

Ec/No Offset

BSC6900

ECNOTHRES

Ec/No Threshold for


Layer Of 3G Cell

BSC6900

ECSC

ECSC

BSC6900

ECSN

End Serial No.

BSC6900

ED

End Date

BSC6900

ED

End Date

BSC6900

ED

End Date

BSC6900

EDATE

End Date

BSC6900

EDAY

End date

BSC6900

EDBLASTTIME

Number of Satisfactory
Measurements

BSC6900

EDBSTATTIME

Total Number of
Measurements

BSC6900

EDBSYSFLOWLEV

Subcell HO Allowed Flow


BSC6900
Control Level

EDGE

EDGE

BSC6900

EDGEADJLASTTIME

Edge HO AdjCell Valid


Time

BSC6900

EDGEADJSTATTIME

Edge HO AdjCell Watch


Time

BSC6900

EDGELAST

Handover Algorithm II
Edge HO Valid Time

BSC6900

EDGELAST1

Handover Algorithm I
Edge HO Valid Time

BSC6900

EDGESTAT

Handover Algorithm II
Edge HO Watch Time

BSC6900

EDGESTAT1

Handover Algorithm I
Edge HO Watch Time

BSC6900

EFTIMMFLAG

Effect Immediately Flag

BSC6900

EGPRS11BITCHANREQ

Support 11BIT EGPRS


Access

BSC6900

EGPRS2A

EGPRS2-A

BSC6900

EGPRSBEPLIMIT8PSK

EDGE 8PSK Quality


Threshold

BSC6900

EGPRSBEPLIMITGMSK

EDGE GMSK Quality


Threshold

BSC6900

EM

EndType

BSC6900

EMCPRILV

Priority of Emergency
Call

BSC6900

EMERGENCY

Emergency verification

BSC6900

EMITTHD

Error emit threshold

BSC6900

EMLDSCP

EML DSCP

BSC6900

EMLPPEN

Allow EMLPP

BSC6900

EMLPPPRIORITY

eMLPP Priority In Paging

BSC6900

EMLPPPRIORITY

eMLPP Priority

BSC6900

EMLPRI

EML Priority

BSC6900

EMLSP

EML Service PRI

BSC6900

EMLVLANID

EML VlanId

BSC6900

EMONTH

End month

BSC6900

EMSIP

EMS IP Address

BSC6900

ENABLE

Fallback Function Enable BSC6900

ENABLED

TMA Power Supply


Enabled

BSC6900

ENCRY

Encryption Algorithm

BSC6900

ENCRYMODE

Transport Encrypted
Mode

BSC6900

ENCRYMODE

The Encrypted Mode

BSC6900

End2EndTraceState

Support End-to-end User


BSC6900
Tracing Function

ENDAID

End Alarm ID

BSC6900

ENDCIC

End CIC

BSC6900

ENDCIC

End CIC

BSC6900

EndDayDSTPA

Prohibit Power Saving


End Day

BSC6900

ENDHEATTEMP

Heater Shutdown
Temperature

BSC6900

EndMonthDSTPA

Prohibit Power Saving


End Month

BSC6900

ENDSUBTS

End Sub Timeslot NO.

BSC6900

EndTimeTACloseTrxPA

Time When the Function


Is Disabled

BSC6900

ENDTS

End TS

BSC6900

ENDTS

End TS

BSC6900

ENDTS

End Timeslot NO.

BSC6900

ENF

Status

BSC6900

ENF

Subtask Status

BSC6900

ENGOVERLDTHRSH

En Iuo Out Cell General


OverLoad Thred

BSC6900

ENGSMPSDLMACFLOWCT User Plane DL Flow Ctrl


RL
Switch

BSC6900

ENIUO

Enhanced Concentric
Allowed

BSC6900

ENLDHOPRD

Load Classification HO
Period

BSC6900

ENLDHOSTP

Load Classification HO
Step

BSC6900

ENLOWLDTHRSH

En Iuo Out Cell Low Load


BSC6900
Thred

ENPREEMPTTRANSADMT

Transmission Resource
Preempting Support

BSC6900

ENQUETRANSADMT

Transmission Resource
Queuing Support

BSC6900

ENSOVERLDTHRSH

En Iuo Out Cell Serious


OverLoad Thred

BSC6900

ENTCHADJALLOW

Enhanced TCH Adjust


Allowed

BSC6900

ENTITYT

Destination entity type

BSC6900

ENTITYT

Local entity type

BSC6900

ENUTOOLOADINILEV

IniLev for EnUtoO Load


HO

BSC6900

EPLCSwitch

EPLC Switch

BSC6900

ERCODE

Return Code

BSC6900

ERGCALLDIS

Emergent Call Disable

BSC6900

ERRALARMTHD

Error-frame alarm
threshold

BSC6900

ERRDETECTSW

Error-frame detect switch BSC6900

ESLDSCP

ESL DSCP

BSC6900

ESLPRI

ESL Priority

BSC6900

ESLSP

ESL Service PRI

BSC6900

ESLVLANID

ESL VlanId

BSC6900

ESSN

End Sync Serial No.

BSC6900

ESTABINDTIMER

T3101

BSC6900

ESTINDL3MSGTAFLAG

Add TA to A Interface EST


BSC6900
IND

ESTTIME

Ring II Rotating Penalty


Time

BSC6900

ET

End Time

BSC6900

ET

End Time

BSC6900

ET

End Time

BSC6900

ET

End Time

BSC6900

ET

Execute Type

BSC6900

ET

End Time

BSC6900

ET

End Time

BSC6900

ET

EndTime

BSC6900

ETD

End Date

BSC6900

ETIME

End Time

BSC6900

ETP

Log Type

BSC6900

ETT

End Time

BSC6900

EWEEK

End week

BSC6900

EWSEQ

End week sequence

BSC6900

EX_ANO1_SIG_MAX

Upper Limit of Signal


Output of External
Analog 1

BSC6900

EX_ANO1_SIG_MIN

Lower Limit of Signal


Output of External
Analog 1

BSC6900

EX_ANO1_TYPE

Sensor Type of External


Analog 1

BSC6900

EX_ANO1_VAL_MAX

Upper Limit of
Measurement Range of
External Analog 1

BSC6900

EX_ANO1_VAL_MIN

Lower Limit of
Measurement Range of
External Analog 1

BSC6900

EX_ANO2_SIG_MAX

Upper Limit of Signal


Output of External
Analog 2

BSC6900

EX_ANO2_SIG_MIN

Lower Limit of Signal


Output of External
Analog 2

BSC6900

EX_ANO2_TYPE

Sensor Type of External


Analog 2

BSC6900

EX_ANO2_VAL_MAX

Upper Limit of
Measurement Range of
External Analog 2

BSC6900

EX_ANO2_VAL_MIN

Lower Limit of
Measurement Range of
External Analog 2

BSC6900

EX_ANO3_SIG_MAX

Upper Limit of Signal


Output of External
Analog 3

BSC6900

EX_ANO3_SIG_MIN

Lower Limit of Signal


Output of External
Analog 3

BSC6900

EX_ANO3_TYPE

Sensor Type of External


Analog 3

BSC6900

EX_ANO3_VAL_MAX

Upper Limit of
Measurement Range of
External Analog 3

BSC6900

EX_ANO3_VAL_MIN

Lower Limit of
Measurement Range of
External Analog 3

BSC6900

EX_ANO4_SIG_MAX

Upper Limit of Signal


Output of External
Analog 4

BSC6900

EX_ANO4_SIG_MIN

Lower Limit of Signal


Output of External
Analog 4

BSC6900

EX_ANO4_TYPE

Sensor Type of External


Analog 4

BSC6900

EX_ANO4_VAL_MAX

Upper Limit of
Measurement Range of
External Analog 4

BSC6900

EX_ANO4_VAL_MIN

Lower Limit of
Measurement Range of
External Analog 4

BSC6900

EXCACC

Exclusive Access

BSC6900

EXCEPFRAMETHRES

Exceptional Frame
Threshold of Mute Detect BSC6900
Class1

EXPDLRXLEV

Expected DL RX_LEV

BSC6900

EXPULRXLEV

Expected UL RX_LEV

BSC6900

EXT2GCELLID

Cell Index

BSC6900

EXT2GCELLNAME

Cell Name

BSC6900

EXT3GCELLID

Cell Index

BSC6900

EXT3GCELLNAME

Cell Name

BSC6900

EXTADJCELLID

BSC Adjacent Cell Index

BSC6900

EXTADJCELLNAME

BSC Adjacent Cell Name

BSC6900

EXTCELLTHRENH

Extended Cell
Throughput
Enhancement

BSC6900

EXTFlag

Extended Switch of Input


BSC6900
Alarm

EXTMEASORD

Extension Measurement
Command

BSC6900

EXTRPTPERIOD

Extension MR Period

BSC6900

EXTRPTTYPE

Extension MR Type

BSC6900

EXTTP

Cell Extension Type

BSC6900

EXTUTBFNODATA

Not Send Dummy


Message with Extended
Uplink TBF

BSC6900

FACCHRESENDINT

FACCH Msg Resend


Interval

BSC6900

FACCHSENDNOTMSGIND

FACCH Send Notification


Msg Indication

BSC6900

FACCHSENDPGMSGIND

FACCH Send Paging Msg


Indication

BSC6900

FACTORSW

TRM Factor switch

BSC6900

FACTORYMODE

Factory Mode

BSC6900

FAILSIGSTRPUNISH

Penalty Level after HO


Fail

BSC6900

FANADJUSTCOMMAND0

Continuous adjustment
command

BSC6900

FANADJUSTCOMMAND1

Discrete adjustment
command

BSC6900

FANADJUSTCOMMAND2

Duty ratio adjustment


command

BSC6900

FANADJUSTMODE

Fan adjustment mode

BSC6900

FANFLAG

Fan Type

BSC6900

FANSPEEDMODE

Speed adjustment mode BSC6900

FANTYPE

FanBox Type

BSC6900

FASTCALLTCHTHRESHOLD

Fast Call Setup TCH


Usage Threshold

BSC6900

FASTCNETFLAG

Configure Ring II

BSC6900

FaultDetectSwitch

Fault Detect Switch

BSC6900

FC

Flow Control

BSC6900

FC

Physical layer flow


control switch

BSC6900

FCETHD

Flow Control End


Threshold

BSC6900

FCINDEX

Flow control parameter


index

BSC6900

FCINDEX

Flow control parameter


index

BSC6900

FCINDEX

Flow control parameter


index

BSC6900

FCINDEX

Flow control parameter


index

BSC6900

FCINDEX

Flow control parameter


index

BSC6900

FCINDEX

Flow control parameter


index

BSC6900

FCINDEX

Flow control parameter


index

BSC6900

FCN

Cabinet No. of Parent


BTS

BSC6900

FCN

Cabinet No. of Father


BTS

BSC6900

FCSTHD

Flow Control Start


Threshold

BSC6900

FCSTYPE

CRC check mode

BSC6900

FCSTYPE

CRC check mode

BSC6900

FCSW

Flow control switch

BSC6900

FCV

Float-Charging Voltage

BSC6900

FDDBA1TAG

FDDBA1 Input Tag

BSC6900

FDDBA2TAG

FDDBA2 Input Tag

BSC6900

FDDCELLOFF

FDD Reporting Offset

BSC6900

FDDCELLTHRED

FDD Reporting Threshold BSC6900

FDDDIVERSITY

Diversity Indication

BSC6900

FDDDLUARFAN

Downlink Frequency

BSC6900

FDDECQUALTHRSH

PS FDD Ec/No Quality


Threshold

BSC6900

FDDFREQCNUM

FDD Multirate Reporting

BSC6900

FDDQMIN

FDD Qmin

BSC6900

FDDQMINOFFSET

FDD Qmin Offset

BSC6900

FDDQOFF

FDD Q Offset

BSC6900

FDDREP

FDD REP QUANT

BSC6900

FDDRSCPMIN

FDD RSCP Min.

BSC6900

FDDRSCPQUALTHRSH

PS FDD RSCP Quality


Threshold

BSC6900

FDDSCRAMBLE

Scrambling Code

BSC6900

FDWINDOW

Fast judgement window

BSC6900

FERRPTEN

FER Report Enable

BSC6900

FERSTATTH1

FER Threshold 1

BSC6900

FERSTATTH2

FER Threshold 2

BSC6900

FERSTATTH3

FER Threshold 3

BSC6900

FERSTATTH4

FER Threshold 4

BSC6900

FERSTATTH5

FER Threshold 5

BSC6900

FERSTATTH6

FER Threshold 6

BSC6900

FERSTATTH7

FER Threshold 7

BSC6900

FHMODE

Frequency Hopping Mode BSC6900

FILE

Target File Path

BSC6900

FILE

File Name

BSC6900

FileName

File Name

BSC6900

FILEPATH

Export File Path

BSC6900

FILETYPE

Log File Type

BSC6900

FILTERWNDSIZE

Filter Window Size

BSC6900

FIN

Final

BSC6900

FINESTEPPCALLOWED

0.2dB Power Control


Enable

BSC6900

FIRESET

Fire-extinguishing
Equipment

BSC6900

FIXABISPRIORABISLOADT
HRED

Fix Abis Prior Choose


Load Thred

BSC6900

FlashAlmClrThd

Flash Alarm Clear


Threshold

BSC6900

FlashAlmOccurThd

Flash Alarm Occur


Threshold

BSC6900

FlashFilterEn

Flash Filter Enable

BSC6900

FlashStatisAlmClrTW

Flash Statistic Alarm


Clear Time Window

BSC6900

FlashStatisAlmOccurTW

Flash Statistic Alarm


Raise Time Window

BSC6900

FLEXABISMODE

Flex Abis Mode

BSC6900

FLEXMAIO

Start Flex MAIO Switch

BSC6900

FLEXTSCSWITCH

Flex TSC Switch

BSC6900

FlowCountPeriodTicks

Flux Measurement Period BSC6900

FLOWCOUNTPERIODTSRA Fast Flux Measurement


PIDADJ
Period

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLTPARAA1

Filter Parameter A1

BSC6900

FLTPARAA2

Filter Parameter A2

BSC6900

FLTPARAA3

Filter Parameter A3

BSC6900

FLTPARAA4

Filter Parameter A4

BSC6900

FLTPARAA5

Filter Parameter A5

BSC6900

FLTPARAA6

Filter Parameter A6

BSC6900

FLTPARAA7

Filter Parameter A7

BSC6900

FLTPARAA8

Filter Parameter A8

BSC6900

FLTPARAB

Filter Parameter B

BSC6900

FLUSHTRANSFERSWITCH

FLUSH-LL PDU Transfer


Switch

BSC6900

FMSMAXOPCC

MS_TXPWR_MAX_CCH

BSC6900

FMUTYPE

FMU Board Type

BSC6900

FN

File Name

BSC6900

FN

File Name

BSC6900

FN

File Name

BSC6900

FN

File Name

BSC6900

FN

File Name

BSC6900

FN

File Name

BSC6900

FN

File Name

BSC6900

FORBIDEDGU

Allow E Down G Up
Switch

BSC6900

FORBIDNO7FLASHDISC

Anti DPC Intermittent


Disconnect Timer

BSC6900

Force_Limit_Time

Force Limit Time

BSC6900

Force2Phase

Force MS Two-phase
Access

BSC6900

FORCEDCELLEFRSWITCH

Allow Forced EFR in Cell

BSC6900

FORCEMSACCESS

Force MS to Send Ho
Access SWITCH

BSC6900

FPN

Dest Father BTS Port No. BSC6900

FPN

Dest Father BTS Port No. BSC6900

FPTIMER

Maximum Delay
Time[ms]

BSC6900

FQBSICOPTSWITCH

Freq. and BSIC Optimize


Switch

BSC6900

FQBSICSWITCH

Freq. and BSIC Plan


Switch

BSC6900

FQBSICSWITCH1

Freq. and BSIC Plan


Switch

BSC6900

FRAGSIZE

MP flake size

BSC6900

FRAMEOFFSET

Frame Offset

BSC6900

FRAMEOFFSET

Frame Offset [Frame No] BSC6900

FRDLDTX

FR Use Downlink DTX

BSC6900

FREQ

Frequency

BSC6900

FREQ

Time Mode

BSC6900

FREQ

Time Mode

BSC6900

FREQ1

Frequency 1

BSC6900

FREQ10

Frequency 10

BSC6900

FREQ11

Frequency 11

BSC6900

FREQ12

Frequency 12

BSC6900

FREQ13

Frequency 13

BSC6900

FREQ14

Frequency 14

BSC6900

FREQ15

Frequency 15

BSC6900

FREQ16

Frequency 16

BSC6900

FREQ17

Frequency 17

BSC6900

FREQ18

Frequency 18

BSC6900

FREQ19

Frequency 19

BSC6900

FREQ2

Frequency 2

BSC6900

FREQ20

Frequency 20

BSC6900

FREQ21

Frequency 21

BSC6900

FREQ22

Frequency 22

BSC6900

FREQ23

Frequency 23

BSC6900

FREQ24

Frequency 24

BSC6900

FREQ25

Frequency 25

BSC6900

FREQ26

Frequency 26

BSC6900

FREQ27

Frequency 27

BSC6900

FREQ28

Frequency 28

BSC6900

FREQ29

Frequency 29

BSC6900

FREQ3

Frequency 3

BSC6900

FREQ30

Frequency 30

BSC6900

FREQ31

Frequency 31

BSC6900

FREQ32

Frequency 32

BSC6900

FREQ33

Frequency 33

BSC6900

FREQ34

Frequency 34

BSC6900

FREQ35

Frequency 35

BSC6900

FREQ36

Frequency 36

BSC6900

FREQ37

Frequency 37

BSC6900

FREQ38

Frequency 38

BSC6900

FREQ39

Frequency 39

BSC6900

FREQ4

Frequency 4

BSC6900

FREQ40

Frequency 40

BSC6900

FREQ41

Frequency 41

BSC6900

FREQ42

Frequency 42

BSC6900

FREQ43

Frequency 43

BSC6900

FREQ44

Frequency 44

BSC6900

FREQ45

Frequency 45

BSC6900

FREQ46

Frequency 46

BSC6900

FREQ47

Frequency 47

BSC6900

FREQ48

Frequency 48

BSC6900

FREQ49

Frequency 49

BSC6900

FREQ5

Frequency 5

BSC6900

FREQ50

Frequency 50

BSC6900

FREQ51

Frequency 51

BSC6900

FREQ52

Frequency 52

BSC6900

FREQ53

Frequency 53

BSC6900

FREQ54

Frequency 54

BSC6900

FREQ55

Frequency 55

BSC6900

FREQ56

Frequency 56

BSC6900

FREQ57

Frequency 57

BSC6900

FREQ58

Frequency 58

BSC6900

FREQ59

Frequency 59

BSC6900

FREQ6

Frequency 6

BSC6900

FREQ60

Frequency 60

BSC6900

FREQ61

Frequency 61

BSC6900

FREQ62

Frequency 62

BSC6900

FREQ63

Frequency 63

BSC6900

FREQ64

Frequency 64

BSC6900

FREQ7

Frequency 7

BSC6900

FREQ8

Frequency 8

BSC6900

FREQ9

Frequency 9

BSC6900

FREQADJ

Frequency Adjust Switch BSC6900

FREQADJVALUE

Frequency Adjust Value

BSC6900

FREQBAND

Frequency Band Attribute BSC6900

FREQLOADSHARETRAFFT
HRSH

GSM900 Band Traffic


Load Share Threshold

BSC6900

FREQLST

Freq Band List

BSC6900

FREQREUSEMODE

Frequency Reuse Mode

BSC6900

FREQS

Frequency List

BSC6900

FREQSCANRLSTTYPE

Frequency Scan Result


Type

BSC6900

FRINGEHOEN

Edge HO Allowed

BSC6900

FRULDTX

FR Uplink DTX

BSC6900

FSN

Slot No. of Father BTS

BSC6900

FSN

Slot No. of Father BTS

BSC6900

FSRN

Subrack No. of Parent


BTS

BSC6900

FSRN

Subrack No. of Father


BTS

BSC6900

FT

File Type

BSC6900

FTI

Factor table index

BSC6900

FTI

Factor table index

BSC6900

FTI

Factor table index

BSC6900

FULLTOHALFHOATCBOFFS
F-H ATCB Offset Overlay
ET

BSC6900

FULLTOHALFHODURATION F-H Ho Duration

BSC6900

FULLTOHALFHOLASTTIME F-H Ho Last Time

BSC6900

FULLTOHALFHOPATHOFFS F-H Pathloss Offset


ET
Overlay

BSC6900

FULLTOHALFHOPERIOD

F-H Ho Period

BSC6900

FULLTOHALFHOSTATTIME

F-H Ho Stat. Time

BSC6900

FWDCONGBW

Forward congestion
remain bandwidth

FWDCONGCLRBW

Forward congestion clear


BSC6900
remain bandwidth

FWDCONGCLRTH

Forward congestion clear


BSC6900
remain ratio

FWDCONGTH

Forward congestion
remain ratio

BSC6900

FWDOVLDCLRRSVBW

Forward overload
congestion clear remain
bandwidth

BSC6900

FWDOVLDCLRTH

Forward overload
congestion clear remain
ratio

BSC6900

FWDOVLDRSVBW

Forward overload
congestion remain
bandwidth

BSC6900

FWDOVLDTH

Forward overload
congestion remain ratio

BSC6900

FWDRESVHOTH

Forward handover
reserved ratio

BSC6900

FWDRSVHOBW

Forward handover
reserved bandwidth

BSC6900

G2G3GLdBlcDeltaThrd

CS 2G 3G Load Balance
Delta Threshold

BSC6900

G2GLoadAdjustCoeff

2G Load Adjustment
Coefficient

BSC6900

G711_Mode

G711 Mode

BSC6900

GAMMA

GAMMA

BSC6900

GATHET

Offset Information
Collection End Time

BSC6900

BSC6900

GATHLOD

Load Threshold of Offset


BSC6900
Collection

GATHON

Offset Information
Collection Switch

BSC6900

GATHST

Offset Information
Collection Start Time

BSC6900

GBRQOS

Support GBR QoS

BSC6900

GCChk

Group Call Check

BSC6900

GCDF

GCDF

BSC6900

GCSCHNASSULCHNEN

VGCS Channel Assign in


Channel Enable

BSC6900

GCSIMPREEMPTIONEN

VGCS IM Preemption
Enable

BSC6900

GLOBALROUTESW

Global route
management switch

BSC6900

GMSKDELAY

Diversity Transmitter
GMSK Delay

BSC6900

GPRS

Support GPRS

BSC6900

GPRS

GPRS

GPRSCELLRESELECTHYES GPRS Cell Reselect


TERESIS
Hysteresis

BSC6900

BSC6900

GPRSCHPRI

PDCH Channel Priority


Type

BSC6900

GPRSHCSTHR

Threshold of HCS Signal


Strength

BSC6900

GPRSPENALTYTIME

GPRS Penalty Time

BSC6900

GPRSRXQUALLIMIT

GPRS Quality Threshold

BSC6900

GPRSTEMPOFFSET

GPRS Temporary Offset

BSC6900

GPSORGLONASS

GPS or Glonass

BSC6900

GPSPERIOD

GPS data report period

BSC6900

GRADEACCALLOW

Grade Access Allow

BSC6900

GROUPCALLNUM1

Group Call Num 1

BSC6900

GROUPCALLNUM2

Group Call Num 2

BSC6900

GROUPINDEX

BSC Node Redundancy


Group Index

BSC6900

GROUPNAME

BSC Node Redundancy


Group Name

BSC6900

GROUPRELTSNUM

Group Release TS
Number

BSC6900

GRPID

Transport Resource
Group No.

BSC6900

GRPT

Transport Resource
Group Type

BSC6900

GS

Geography Scope

BSC6900

GSMCSBWRATE

CS ratio

BSC6900

GSMCSUSERHIGHPRILEV

GSM CS High Level


Standard

BSC6900

GSMFREQCNUM

Serving Band Reporting

BSC6900

GSMTOTDALLOWED

GSM-to-TD Cell
Reselection Allowed

BSC6900

GUARDTYPE

ICMP type which will be


guarded

BSC6900

GWIP

BTS SeGW IP Address

BSC6900

GWIP

BTS Security Gateway IP


BSC6900
Address

HalfRateDataSupport

Support Half Rate Data


Service

BSC6900

HALFTOFULLATCBOFFSET H-F ATCB Offset Overlay

BSC6900

HALFTOFULLHODURATION H-F Ho Duration

BSC6900

HALFTOFULLHOLASTTIME H-F Ho Last Time

BSC6900

HALFTOFULLHOPATHOFFS H-F Pathloss Offset


ET
Overlay

BSC6900

HALFTOFULLHOSTATTIME H-F Ho Stat. Time

BSC6900

HAVETT1

Antenna Tributary 1 Flag BSC6900

HAVETT2

Antenna Tributary 2 Flag BSC6900

HBINTER

Heartbeat interval

BSC6900

HCN

Head Cabinet No.

BSC6900

HCSLASTTIME

HCS HO Valid Time

BSC6900

HCSSTATTIME

HCS HO Watch Time

BSC6900

HIERPWRPARA1

Hierarchical Power Para1 BSC6900

HIERPWRPARA2

Hierarchical Power Para2 BSC6900

HiFreqBandSupport

Support High Frequency


Band

HIGHESTPRIORITQUALFIR Highest Priority for


ST
Quality First

HIGHLEVPREEM

Highest-Priority MSs
Rapid Preemption

BSC6900

BSC6900

BSC6900

HIGHPRIUSERQUALFIRST

Highest Priority User


Quality First

BSC6900

HIGHTEMPLOADPWROFF

High Temp Load Power


Off

BSC6900

HISPRIOALLOW

History Record Priority


Allowed

BSC6900

HISTORYPWDNUM

Maximum History
Password Numbers

BSC6900

HMCDTM

Support HMC DTM

BSC6900

HOALGOPERMLAY

Pref. Subcell in HO of
Intra-BSC

BSC6900

HOBTWNOTHOPALLOW

Handover Between
Operators Allow

BSC6900

HOCDCMINDWPWR

Min DL Level on
Candidate Cell

BSC6900

HOCDCMINUPPWR

Min UL Level on
Candidate Cell

BSC6900

HOCELLIDTYPE

Specify Index of Cell


Handover to

BSC6900

HOCELLNAME

Cell Name of Handover


to

BSC6900

HOCTRLSWITCH

Current HO Control
Algorithm

BSC6900

HODIRFORECASTEN

Handover Direction
Forecast Enable

BSC6900

HODIRLASTTIME

Handover Direction
Forecast Last Times

BSC6900

HODIRSTATIME

Handover Direction
Forecast Statistic Times

BSC6900

HODOWNTRIGE

Quick Handover Down


Trigger Level

BSC6900

HODURT3G

FDD 3G Better Cell HO


Valid Time

BSC6900

HODURT3GTDD

TDD 3G Better Cell HO


Valid Time

BSC6900

HOECNOTH3G

Ec/No Threshold for


Better 3G Cell HO

BSC6900

HOLASTTIME

Quick Handover Last


Time

BSC6900

HOMOD

Handover Scope

BSC6900

HOOFFSET

Quick Handover Offset

BSC6900

HOOLRXLEVOFFSET

Handover to Overlayer
RxLev Offset

BSC6900

HOOPTSEL

Inter-rat HO Preference

BSC6900

HOPENALTYTIME

Inter UL/OL Subcells HO


Penalty Time

BSC6900

HOPINDEX

Hop Index

BSC6900

HOPINDEX

Hop Index

BSC6900

HOPMODE

Hop Mode

BSC6900

HOPOWERBOOST

Power Boost before HO


Enabled or Not

HOPRETH2G

HO Preference Threshold
BSC6900
for 2G Cell

HopSingleFreqOptSwitch

Hop Group Single Freq


Optimization

BSC6900

HOPTRXHSN

Hop TRX Group HSN

BSC6900

HOPTRXINDEX

Hop TRX Group Index

BSC6900

HOPTYPE

Hop Type

BSC6900

BSC6900

HOPUNISHVALUE

Quick Handover Punish


Value

BSC6900

HOREFTMR

BSC HO Protect Time

BSC6900

HORSCPTH3G

RSCP Threshold for


Better 3G Cell HO

BSC6900

HoSdcchSpeechVer

Speech VER in SDCCH


HO REQ ACK

BSC6900

HOSTAT3G

FDD 3G Better Cell HO


Watch Time

BSC6900

HOSTAT3GTDD

TDD 3G Better Cell HO


Watch Time

BSC6900

HOSTATICTIME

Quick Handover Static


Time

BSC6900

HOSTTYPE

The host type of


signalling point

BSC6900

HOSTTYPE

HostType

BSC6900

HOTHRES

Inter-layer HO Threshold BSC6900

HOUPTRIGE

Quick Handover Up
Trigger Level

BSC6900

HPANTMODE

Cell Antenna Hopping

BSC6900

HPANTMODE

Cell Antenna Hopping

BSC6900

HPN

Head Port No.

BSC6900

HPRIOR

Highest Priority

BSC6900

HPVFLAG

Hierarchical Power-off
Config. Enabled

BSC6900

HPVTHD

Load Power-off Voltage

BSC6900

HRATESPT

Support Half Rate

BSC6900

HRDLDTX

HR Use Downlink DTX

BSC6900

HRIUOLDRATESELALLOW

Load of UL-OL Cells Rate


BSC6900
Select Allowed

HRULDTX

HR Uplink DTX

BSC6900

HSN

HSN

BSC6900

HSN

Head Slot No.

BSC6900

HSNSW

HSN Modification Switch

BSC6900

HSRN

Head Subrack No.

BSC6900

HT

Hop Type

BSC6900

HTCP

High Temperature Critical


BSC6900
Point

HTDO

High Temperature Delta


Tout

BSC6900

HTSDF

High Temperature
Shutdown Flag

BSC6900

HUM_MASK

Enable Humidity Alarm


Reporting

BSC6900

HUM_THD_HIGH

Upper Limit of Humidity


Alarm

BSC6900

HUM_THD_LOW

Lower Limit of Humidity


Alarm

BSC6900

HUMALAMRTHRESHOLDH

Upper Threshold of
Humidity Alarm

BSC6900

HUMALAMRTHRESHOLDH

Upper Threshold of
Humidity Alarm

BSC6900

HUMALAMRTHRESHOLDL

Lower Threshold of
Humidity Alarm

BSC6900

HUMALAMRTHRESHOLDL

Lower Threshold of
Humidity Alarm

BSC6900

HYSON

Hysteresis for On

BSC6900

IARXTMR

Inactive RX timer

BSC6900

IASUDURAT

Duration

BSC6900

IASUPORT

Port No.

BSC6900

IASUSLCTTMU

Transmission Board Type BSC6900

IATXTMR

Inactive TX timer

BSC6900

IBCAAFRSOFTBLKTHRD

IBCA AMR FR Soft Block


Threshold

BSC6900

IBCAAHRSOFTBLKTHRD

IBCA AMR HR Soft Block


Threshold

BSC6900

IBCAALLOWED

IBCA Allowed

BSC6900

IBCAASSWAITMEASURERP IBCA Assign Waiting Mr


TTIME
Time

IBCACALLINFOFILTERLEN

IBCA Call Information


Filter

IBCACALLSOFTBLOCKTHO IBCA Set-up Call Soft


FFSET
Block Threshold Offset

BSC6900

BSC6900

BSC6900

IBCACALLTARGETCIROFFS Target CIR Offset of IBCA


BSC6900
ET
Set-up Call

IBCADLPATHLOSSOFF

IBCA Downlink Path Loss


BSC6900
Offset

IBCADYNCMEASURENCEL IBCA Dyn Measure


LALLOWED
Neighbour Cell Flag

BSC6900

IBCAEHOASSWAITMEASU
RERPTTIME

IBCA Urgent HO Waiting


Mr Time

BSC6900

IBCAFLEXTSCALLOWED

IBCA Flexible TSC


Allowed

BSC6900

IBCAFORCEDBTSSYNCALL IBCA Forced BTS


BSC6900
OWED
Synchronization Allowed

IBCAFRSOFTBLKTHRD

IBCA FR/EFR Soft Block


Threshold

IBCAHOASSWAITMEASUR IBCA HO Waiting


ERPTTIME
Effective Mr Time

BSC6900

BSC6900

IBCAHRSOFTBLKTHRD

IBCA HR Soft Block


Threshold

BSC6900

IBCAICDMRELEVOFFSET

IBCA ICDM Initial Level


Offset

BSC6900

IBCAICDMSWITCH

IBCA ICDM Switch

BSC6900

IBCAINBSCINFORPTPRD

IBCA Info Report Period


Within BSC

BSC6900

IBCAINITPCRXLEVDLOFFS IBCA Init. Power Control


ET
RexLevDL Offset

BSC6900

IBCAINITPCRXLEVULOFFS IBCA Init. Power Control


ET
RexLevUL Offset

BSC6900

IBCAINITPCRXQUALDLOFF IBCA Init. Pwr Ctrl Rx


SET
Qual DL Offset

BSC6900

IBCAINITPCRXQUALULOFF IBCA Init. Pwr Ctrl Rx


SET
Qual UL Offset

BSC6900

IBCAIUOPATHLOSSOFF

IBCA IUO Path Loss Offset BSC6900

IBCAMAIOUSMTD

IBCA MAIO Using Method BSC6900

IBCAMAXINTFSRCNUM

IBCA Max. Interference


Source Num.

BSC6900

IBCANCELLFLAG

IBCA Neighbor Cell Flag

BSC6900

IBCANCELLPATHLOSSESTI IBCA Pathloss Est of Non.


BSC6900
MATE
MR Ncell

IBCANEWCALLCIROFFSET

Target CIR Offset of IBCA


BSC6900
New Call

IBCANHOASSWAITMEASU IBCA Natural HO Waiting


BSC6900
RERPTTIME
Mr Time

IBCANONMEANCELLSTATN IBCA Non Measurement


UM
Ncell Stat. Num

BSC6900

IBCAOPRREVISEFACTOR

Corrected Factor of IBCA


Priority

BSC6900

IBCAOUTBSCINFORPTPRD

IBCA Info Report Period


Between BSC

BSC6900

IBCAPATHLOSSOFF

IBCA Pathloss Offset

BSC6900

IBCAPLFILTFACTOR

IBCA Path Lose Filter


Factor

BSC6900

IBCARXLEVOFFSET

IBCA RxLev Offset

BSC6900

IBCASCELLPATHLOSS

IBCA Service Cell


Pathloss

BSC6900

IBCASOFTBLKSAICOFF

IBCA Soft Block SAIC


Offset

BSC6900

IBCASOFTBLKSWITCH

IBCA Soft Block Switch

BSC6900

IBCASUBCHNHANDOVERA IBCA Sub-Channel


LLOWED
Handover Allowed

BSC6900

IBCATARGETCIRTHRSH

IBCA MAIO Target C/I


Threshold

BSC6900

IBCAUSEDIUOSUBLAY

IUO IBCA Allowed

BSC6900

IBCAUSRDYNCMEASUREN IBCA User Dyn Measure


CELL
Neighbor Cell

BSC6900

IBCAWAFRSOFTBLKTHRD

IBCA WAMR FR Soft Block


BSC6900
Threshold

ICBALLOW

ICB Allowed

BSC6900

ICF

Intelligent Control Flag

BSC6900

ICMPPKGLEN

ICMP packet Length

BSC6900

ICTHP1DSCP

DSCP of PRI.1
INTACT[QoS]

BSC6900

ICTHP2DSCP

DSCP of PRI.2
INTACT[QoS]

BSC6900

ICTHP3DSCP

DSCP of PRI.3
INTACT[QoS]

BSC6900

ID

Task ID

BSC6900

ID

Task ID

BSC6900

ID

Index

BSC6900

Idle_Code

Idle Code

BSC6900

IDLECODE

Idle code

BSC6900

IDLESDTHRES

Idle SDCCH Threshold N1 BSC6900

IDTYPE

Index Type

BSC6900

IDTYPE

Index Type

BSC6900

IDTYPE

Index Type

BSC6900

IDTYPE

Index Type

BSC6900

IDTYPE

BTS Index Type

BSC6900

IDTYPE

Index Type

BSC6900

IDTYPE

Index Type

BSC6900

IDTYPE

Index Type

BSC6900

IDX

Semipermanent Link
Index

BSC6900

IDXTYPE

Index Type

BSC6900

IDXTYPE

Index Type

BSC6900

IFCBSHAKEHAND

If CB Shake Hand

BSC6900

IFNO

Outgoing Interface No.

BSC6900

IFOFFSETHIG

Positive or Minus Offset

BSC6900

IFOFFSETLOW

Indication Offset

BSC6900

IFREPPRO

Report Process Flag

BSC6900

IGNOREMRNUM

Ignore Measurement
Report Number

BSC6900

IMEI

IMEI

BSC6900

IMMASSAINTERFTIMER

IMM ASS A IF Creation


Timer

BSC6900

IMMASSCBB

Immediate Assignment
Optimized

BSC6900

IMMASSDLSHIFT

Move Immediate
BSC6900
Assignment Down to BTS

IMMASSEN

TCH Immediate
Assignment

BSC6900

IMMASSMAXDELAYTIME

Max Delay of IMM ASS


Retransmit

BSC6900

IMMASSMAXSENDNUM

Max Transmit Times of


IMM ASS

BSC6900

IMMASSRESENDEN

Use IMM ASS Retransmit


BSC6900
Parameter

IMMASSTAALLOW

TA Pref. of Imme-Assign
Allowed

BSC6900

IMMASSTATHRES

TA Threshold of ImmeAssign Pref

BSC6900

IMMFNAD

Immediate Initial Adjust


After Site Reset Enable

BSC6900

IMMREJWAITINDTIMER

T3122

BSC6900

IMSI

IMSI

BSC6900

IMSI

IMSI

BSC6900

INBSCHOTIMER

T3121

BSC6900

INCHLOD

Fine Tuning Threshold

BSC6900

INCHPRD

Fine Tuning Period in BSC BSC6900

INCLUDEANG

Included Angle

BSC6900

INCN

In Port Cabinet No.

BSC6900

INDEN3

Independent E1 Port 3

BSC6900

INFHHOLAST

Intracell F-H HO Last


Time

BSC6900

INFHHOSTAT

Intracell F-H HO Stat


Time

BSC6900

INFOEXCHGLIST

Info Exchange Content

BSC6900

INFRA_RED_MASK

Infrared alarm switch

BSC6900

INHOF2HTH

F2H HO Threshold

BSC6900

INHOH2FTH

H2F HO Threshold

BSC6900

INHOPWROVERLOADTHRE Power Overload


SHOLD
Threshold In Ho. In

BSC6900

INITCDMDF

AMR Starting Mode[F]

BSC6900

INITCDMDH

AMR Starting Mode[H]

BSC6900

INITCDMDWB

AMR Starting Mode[WB]

BSC6900

INMASK

In BSC Mask

BSC6900

INNASSOPTEN

OL Subcell Assignment
Optimization

BSC6900

INNCELLEDGEHOEN

Inner Cell EDGE HO


Enable

BSC6900

INNCELLID

BSC Inner Cell Index

BSC6900

INNCELLNAME

BSC Inner Cell Name

BSC6900

INNLOADHOEN

Load HO of OL Subcell to
BSC6900
UL Subcell

INNLOADHOPERI

OL Subcell Load Diversity


BSC6900
HO Period

INNLOADHOSTEP

Step Length of OL
Subcell Load HO

BSC6900

INNSERIOVERLDTHRED

Inner Cell Serious


OverLoad Thred

BSC6900

INPN

BTS In Port No.

BSC6900

INPN

In BSC Port No.

BSC6900

INPORTNO

DXX In Port No.

BSC6900

INPUTMD

Latitude and Longitude


Input Mode

BSC6900

INRBSCSDHOEN

Inter-BSC SDCCH HO
ALLowed

BSC6900

INSN

In Port Slot No.

BSC6900

INSN

In BSC Slot No.

BSC6900

INSRN

In Port Subrack No.

BSC6900

INSRN

In BSC Subrack No.

BSC6900

INT

Broadcast Interval

BSC6900

INTELEVHOHYST

Adjacent Cell Inter-layer


HO Hysteresis

BSC6900

INTERBANDSTATALGO

Interfere Band Stat


Algorithm Type

BSC6900

INTERCELLHYST

Inter-cell HO Hysteresis

BSC6900

INTERFEREHOPENTIME

Penalty Time on Interfere


BSC6900
HO

INTERFERELASTTIME

Interfere HO Valid Time

BSC6900

INTERFERESTATTIME

Interfere HO Static Time

BSC6900

INTERFHOEN

Interference HO Allowed BSC6900

INTERFPRIALLOW

Interf. Priority Allowed

BSC6900

INTERFTHRES0

Interference Band
Threshold 0

BSC6900

INTERFTHRES1

Interference Band
Threshold 1

BSC6900

INTERFTHRES2

Interference Band
Threshold 2

BSC6900

INTERFTHRES3

Interference Band
Threshold 3

BSC6900

INTERFTHRES4

Interference Band
Threshold 4

BSC6900

INTERFTHRES5

Interference Band
Threshold 5

INTERIORSYNCTMR

BSC Interior Clock


BSC6900
Synchronize Protect Time

INTERPERIOD

Interference Calculation
Period

INTERRATCELLRESELEN

Inter-RAT Cell Reselection


BSC6900
Enable

InterRatCsServiceLoadHo Inter-RAT CS Service HO


Thrd
Load Threshold

BSC6900

BSC6900

BSC6900

INTERRATINBSCHOEN

Inter-RAT In BSC
Handover Enable

BSC6900

InterRatIurgInBscHoEn

Allow Incoming BSC


Handover at Iur-g

BSC6900

InterRATLoadHoEcNoBand Inter-RAT Load HO


Width
Bandwidth [EcNo]

BSC6900

InterRATLoadHoEcNoStart

Inter-RAT Load HO EcNo


at Start Point

InterRATLoadHoEcNoStep

Inter-RAT Hierarchy Load


BSC6900
HO Step [EcNo]

InterRATLoadHoRSCPBand Inter-RAT Load HO


Width
Bandwidth [RSCP]

BSC6900

BSC6900

InterRATLoadHoRSCPStart

Inter-RAT Load HO RSCP


at Start Point

InterRATLoadHoRSCPStep

Inter-RAT Hierarchy Load


BSC6900
HO Step [RSCP]

INTERRATOUTBSCHOEN

Inter-RAT Out BSC


Handover Enable

InterRatServiceLoadHoSw Allow Inter-RAT Load HO


itch
in Access State

BSC6900

BSC6900

BSC6900

INTERVAL

Send PKT Interval[s]

BSC6900

INTERVAL

Relative Time

BSC6900

INTFREQUENCY

Interference Frequency

BSC6900

INTOINNREXLEVTHRED

Incoming OL Subcell HO
Level TH

BSC6900

INTRABSCCODECHOCMDT
T25
IMER

BSC6900

INTRABSCHOTIMER

T3103A

BSC6900

INTRACELLFHHOEN

Intracell F-H HO Allowed

BSC6900

INTRACELLHOEN

Intracell HO Allowed

BSC6900

INTRACELLHOTIMER

T3103C

BSC6900

INTRAMBSC

Co-MBSC

BSC6900

IntRATLoadHOEcNoThr

Inter-RAT Load HO EcNo


Threshold

BSC6900

IntRATLoadHoPeriod

Inter-RAT Hierarchical
Load HO Period

BSC6900

IntRATLoadHORSCPThr

Inter-RAT Load HO RSCP


Threshold

BSC6900

INTSN

In BSC Start Timeslot No. BSC6900

INTSNO

DXX In Time Slot No.

BSC6900

INTV

Time Interval

BSC6900

INTV

OMU Automatic
Switchover Interval

BSC6900

INVALBSICEN

Invalid BSIC Reporting

BSC6900

IP

Physical IP

BSC6900

IP

IP Address

BSC6900

IP

Local IP Address

BSC6900

IP

Remote IP Address

BSC6900

IP

IP Address

BSC6900

IP

FTPServer IP

BSC6900

IPADDR

IP address

BSC6900

IPADDR

IP Address

BSC6900

IPADDR

Local IP address

BSC6900

IPADDR

Local IP address

BSC6900

IPADDR

Packet source IP address BSC6900

IPADDR

Next Hop IP address.

BSC6900

IPADDR

Local IP address

BSC6900

IPADDR1

Master Clock Server IP


Address

BSC6900

IPADDR1

IP Address1

BSC6900

IPADDR2

Slave Clock Server IP


Address

BSC6900

IPADDR2

IP Address2

BSC6900

IPADDR3

IP Address3

BSC6900

IPADDR4

IP Address4

BSC6900

IPEAAT

IP Frame Error Alarm


Threshold

BSC6900

IPEADT

IP Frame Error Alarm


Clearance Threshold

BSC6900

IPHC

Head compress

BSC6900

IPHC

Head compress

BSC6900

IPINDEX

IP address index

BSC6900

IPINDEX

IP address index

BSC6900

IPMUXINDEX

IP MUX Index

BSC6900

IPPHYTRANSTYPE

IP Phy Trans Type

BSC6900

IPPHYTRANSTYPE

IP Physical Tran. Type

BSC6900

ISADDEDTMPCONTROL

DHEU Heater Control


Allowed

BSC6900

ISBASICBSC

Base BSC

BSC6900

ISCHAINNCELL

Chain Neighbor Cell

BSC6900

ISCLKREDUCY

Clock Server
Redundancy

BSC6900

ISCLKREDUCYBAK

Clock Server
Redundancy

BSC6900

ISCONFIGEDRING

Config Ring

BSC6900

ISCONFIGTHD

Configure Check
Thresholds or Not

ISEDGESUPPORT

EDGE Support in External


BSC6900
Neighbour Cell

ISFIRSTCLASS

Is First Class Transport


Resource Group

ISGPRSSUPPORT

GPRS Support in External


BSC6900
Neighbour Cell

ISMAINBCCH

Is Main BCCH TRX

BSC6900

IsMainBSC

Is Main BSC

BSC6900

ISMAINLOCGRP

Is Main Local Group

BSC6900

ISNC2SUPPORT

NC2 Support in External


Neighbour Cell

BSC6900

ISNCMODE

Subnetwork Configure
Mode

BSC6900

ISQOSPATH

IS QOSPATH

BSC6900

ISSPTBSCAISS

Support BSC AISS

BSC6900

ISSPTDEMUS

Demu Configure
Information

BSC6900

ISSUPERBTS

Is Supper BTS

BSC6900

BSC6900

BSC6900

ISSUPPORTBTSLSWITCH

Support BTS Local Switch BSC6900

IsSupportTcPool

Is Support Tc Pool

BSC6900

ISTCBRD

TC board

BSC6900

ISTCCENTRAL

Remote TC Central

BSC6900

ISTMPCTRL

DHEU Temperature
Control

BSC6900

ISTRANCABCON

Tran. Cabinet Configured BSC6900

ITEM

NCCELL No.

BSC6900

ITEMINDEX

Item Index

BSC6900

ITEMVALID

Item Valid

BSC6900

ITEMVALUE

Value

BSC6900

ITFT

Interface Type

BSC6900

ITFType

Interface Type

BSC6900

IUO

Concentric Attribute

BSC6900

IUOCHNTRAN

Dynamic Channel
Conversion Parameter of BSC6900
Concentric Cell

IUOHODURATIME

UO HO Valid Time

BSC6900

IUOHOSTATIME

UO HO Watch Time

BSC6900

IUOTP

Cell IUO Type

BSC6900

J0ALMSWITCH

J0 trace mismatch alarm


BSC6900
switch

J0BYTE_FORMAT

J0 Byte Format

BSC6900

J0RXVALUE

J0 expected incept value BSC6900

J0TXVALUE

J0 transmit value

BSC6900

J0TYPE

J0 type

BSC6900

J1ALMSWITCH

J1 trace mismatch alarm


BSC6900
switch

J1BYTE_FORMAT

J1 Byte Format

J1RXVALUE

J1 expected incept value BSC6900

J1TXVALUE

J1 transmit value

BSC6900

J1TYPE

J1 type

BSC6900

J2ALMSWITCH

J2 mismatch alarm
switch

BSC6900

J2BYTE_FORMAT

J2 Byte Format

BSC6900

J2MODE

J2 length

BSC6900

BSC6900

J2RXVALUE

J2 expected incept value BSC6900

J2TXVALUE

J2 transmit value

JAUTOADD

Automatic Append J Byte BSC6900

JBF

LAPD Jitter Buffer


Algorithm

BSC6900

JITBUFDELAY

PS Jitter Buffer Delay

BSC6900

JITBUFSWITCH

Jitter Buffer switch

BSC6900

K2MODE

K2 Mode

BSC6900

KBIAS

K Bias

BSC6900

KEEPALIVE

Keep-alive timer
length[S]

BSC6900

BSC6900

LAC

Cell LAC

BSC6900

LAC1

Cell LAC

BSC6900

LACPMODE

Aggregation Mode

BSC6900

LATIDECI

Latitude Decimal Part

BSC6900

LATIDEGREE

Latitude Degree Part

BSC6900

LATIINT

Latitude Int Part

BSC6900

LATIMINUTE

Latitude Minute Part

BSC6900

LATISECONDDECI

Latitude Second Decimal


BSC6900
Part

LATISECONDINT

Latitude Second Int Part

BSC6900

LATITUDE

GPS antenna latitude

BSC6900

LATITUDESEC

GPS antenna latitude

BSC6900

LATPRD

Delay measure period


[100ms]

BSC6900

LATSUSTM

Delay adjust suspend


period [LATTH]

BSC6900

LATTH

Rate down threshold for


delay [ms]

BSC6900

LATUDK

average delay down filter


BSC6900
mantissa

LATUPK

average delay up filter


mantissa

BSC6900

LAYER

Layer of The Cell

BSC6900

LAYER

Layer of the cell

BSC6900

LAYHOLOADTH

Inter-Layer HO Load
Threshold

BSC6900

LBCongestProtect1

Lb Congestion Protection
BSC6900
Timer 1

LBCongestProtect2

Lb Congestion Protection
BSC6900
Timer 2

LDRFOUH

LDR Fourth

BSC6900

LDRFST

LDR First

BSC6900

LDRSND

LDR Second

BSC6900

LENO

Local entity No.

BSC6900

Level

MD LEVEL

BSC6900

LEVEL

Alarm Mask Switch

BSC6900

LEVEL

Log Level

BSC6900

LEVEL

Log Level

BSC6900

LEVELRPT

Level Report Switch

BSC6900

LEVHOEN

Level HO Allowed

BSC6900

LEVHOHYST

Inter-layer HO Hysteresis BSC6900

LEVLAST

Layer HO Valid Time

BSC6900

LEVSTAT

Layer HO Watch Time

BSC6900

LGCAPPTYPE

Logic function type

BSC6900

LGCAPPTYPE

Logical function type

BSC6900

LGCAPPTYPE

Logical function type

BSC6900

LGCUSAGETYPE

Application type of
POUc_TDM

BSC6900

LGIDX

PbSL Logical Index

BSC6900

LHUMTHD

Lower Humidity
Threshold

BSC6900

LICALMCTHD

Alarm occur threshold

BSC6900

LICALMRTHD

Alarm recover threshold

BSC6900

LINKNO

Link No.

BSC6900

LISTTYPE

Query Type

BSC6900

LKTATE

Link rate type

BSC6900

LL

Lower Limit

BSC6900

LL

Lower Limit

BSC6900

LLCN

Channel No.

BSC6900

LNA1

LNA Threshold1

BSC6900

LNA2

LNA Threshold2

BSC6900

LNKNUMMODE

Tributary Numbering

BSC6900

LNKRATE

Semipermanent Link
Rate

BSC6900

LNKREDFLAG

Initial bearing traffic


active tag

BSC6900

LNKSLSMASK

Signalling link mask

BSC6900

LNKSLSMASK

Signalling link mask

BSC6900

LoadAccThres

Load handover Load


Accept Threshold

LOADBALANCEALG

MSC Pool Load Balancing


BSC6900
Algorithm Select

LOADBROADCASTPERIOD

NC2 Load Broadcast


Period

BSC6900

LOADCURRENTDIV

Load Current Shunt


Coefficient

BSC6900

LOADHOAD

Enhanced Load HO
Allowed

BSC6900

BSC6900

LoadHoEn

Load Handover Support

BSC6900

LoadHoEnExt2G

Load Handover Support

BSC6900

LoadHoEnExt3G

Load Handover Support

BSC6900

LOADHOPBGTMARGIN

Load HO PBGT Threshold BSC6900

LOADHOPENTIME

Penalty Time on Load HO BSC6900

LOADHOPENVALUE

Penalty Value on Load


HO

BSC6900

LOADHOPERIOD

Load HO Step Period

BSC6900

LOADHOSTEP

Load HO Step Level

BSC6900

LOADHOUSRRATIO

HO Ratio of Enhanced
Load HO Algorithm

BSC6900

LOADOFFSET

Load HO Bandwidth

BSC6900

LOADPWROFFEN

Load Power-off Allowed


State

BSC6900

LOADRESELALLOW

Cell Load Reselection


Allowed

BSC6900

LOADRESELMAXRXLEV

Load Reselect Level


Threshold

BSC6900

LOADRESELRXTHRSH

Load Reselection Receive


BSC6900
Threshold

LOADRESELSTARTTHRSH

Load Reselection Start


Threshold

BSC6900

LOADSHAREALLOW

Balance Traffic Allowed

BSC6900

LOADSTATYPE

Type of Cell Load


Calculation

BSC6900

LOADTHSW

TRM Load Threshold


switch

BSC6900

LocalBSCID

Local BSC ID

BSC6900

LOCALIP

Local IP Address

BSC6900

LOCALIP

Local IP Address

BSC6900

LOCALIP

Local IP address

BSC6900

LOCALIP

Local IP address

BSC6900

LOCALNSVLI

Local NSVL ID

BSC6900

LOCALPORTNO

Local Port No.

BSC6900

LOCGRPNO

Location Group No.

BSC6900

LOCGRPNO

Location Group No.

BSC6900

LOCINFOKEY

Filter of Location
Information

BSC6900

LOCIP1

First local IP address

BSC6900

LOCIP2

Second local IP address

BSC6900

LOCKST

Set Locked/Unlock

BSC6900

LOCPN

Local SCTP port No.

BSC6900

LODCTRL

Board Start Load Control. BSC6900

LODMODE

Loading Mode

BSC6900

LOGCTHD

Log control threshold

BSC6900

LOGCTHD

Log control threshold

BSC6900

LOGPORTFLAG

Logic Port Flag

BSC6900

LOGPORTNO

Logic Port No.

BSC6900

LOGPORTSN

Logic Port Slot No.

BSC6900

LOGRTHD

Log restore threshold

BSC6900

LOGRTHD

Log restore threshold

BSC6900

LOGSW

Log control switch

BSC6900

LOGTYPE

Log File Type

BSC6900

LOGTYPE

Log Type

BSC6900

LONGIDECI

Longitude Decimal Part

BSC6900

LONGIDEGREE

Longitude Degree Part

BSC6900

LONGIINT

Longitude Int Part

BSC6900

LONGIMINUTE

Longitude Minute Part

BSC6900

LONGISECONDDECI

Longitude Second
Decimal Part

BSC6900

LONGISECONDINT

Longitude Second Int


Part

BSC6900

LONGITUDE

GPS antenna longitude

BSC6900

LONGITUDESEC

GPS antenna longitude

BSC6900

LoopLevel

Loop Level

BSC6900

LOOPMODE

Loopback Type

BSC6900

LOOPSW

Loop Detect Switch

BSC6900

LOOPTYPE

Loop type

BSC6900

LOOSESDCCHLOADTHRED

IBCA Loose Trx SDCCH


Load Threshold

BSC6900

LOPDIR

Loop Direction

BSC6900

LOPLOC

Loop Position

BSC6900

LOPT

Loop type

BSC6900

LOPT

Loop type.

BSC6900

LOPTIME

Loop Time

BSC6900

LOSTSUSTM

Suspend times after


bandwidth adjusted

BSC6900

LOWLEVSUBRESPREEMPT Low-level Sublink


BSC6900
FLG
Resource Preempt Switch

LOWLEVSUBRESPREEMPT Low Lev Sub Res


FLG
Preempt Flag

LOWNOISESWH

Diversity LNA Bypass


Permitted

LOWRXLEVOLFORBIDSWIT Allocate OL Channel


CH
Based on RX Level

BSC6900

BSC6900

BSC6900

LOWTEMPLOADPWROFF

Low Temperature
StartLoadPower-off
Allowed State

BSC6900

LOWTEMPLOADPWROFF

Low Temperature
StartLoadPower-off
Allowed State

BSC6900

LPBKMODE

Loop Back Mode

BSC6900

LPN

IP Logic Port No.

BSC6900

LPN

Logic port No.

BSC6900

LPN

Logic port No.

BSC6900

LPNSN

IP Logic Port Slot No.

BSC6900

LPNTYPE

Type of the logic port

BSC6900

LQCMODE

Link Quality Control


Mode

BSC6900

LSDF

Load Shutdown Flag

BSC6900

LSDV

Load Shutdown Voltage

BSC6900

LSRTRD

LDR Third

BSC6900

LSTCMD

Whether Include List


Command

BSC6900

LstFormat

Result list format

BSC6900

LSTFORMAT

Result List Format

BSC6900

LT

Load type

BSC6900

LT

Log Type

BSC6900

LT

Log Type

BSC6900

LTCP

Low Temperature Critical


BSC6900
Point

LTEMTHD

Lower Temperature
Threshold

BSC6900

LTFERLOWTH

Uplink Long-term FER


Lower Threshold

BSC6900

LTFERTGT

Uplink Long-term FER


Target

BSC6900

LTFERUPTH

Uplink Long-term FER


Upper Threshold

BSC6900

LTTHADJFA

Uplink Threshold Adjust


Factor

BSC6900

LVDS252DSPNUM

Number of DSPs with 252


BSC6900
LVDS Links

Lvl1Vswr

Lvl1 Vswr

BSC6900

Lvl2Vswr

Lvl2 Vswr

BSC6900

LVSDF

Low Voltage Shutdown


Flag

BSC6900

M3UASRVPN

M3UA service listening


port No.

BSC6900

MAC

MAC Address

BSC6900

MACEAAT

MAC Frame Error Alarm


Threshold

BSC6900

MACEADT

MAC Frame Error Alarm


Clearance Threshold

BSC6900

MACODINGMOD

ARFCN Coding Scheme

BSC6900

MAIDX

MA Index

BSC6900

MAINBCCHPWDTACTCHEN

Power Derating Active


Channel Enabled

BSC6900

MAINBCCHPWRDTEN

Power Derating Enabled

BSC6900

MAINBCCHPWRDTETIME

Power Derating End Time BSC6900

MAINBCCHPWRDTRANGE

Power Derating Range

BSC6900

MAINBCCHPWRDTSTIME

Power Derating Start


Time

BSC6900

MAINDEVTAB

PTU Main Dev. Tab

BSC6900

MAINDEVTAB

BTS Interface Board Bar


Code 1

BSC6900

MAINLOCGRPNO

Main Location Group No. BSC6900

MAINPORTNO

Main Port No

BSC6900

MainVer

Main Version No.of TMU

BSC6900

MAIO1

MAIO 1

BSC6900

MAIO10

MAIO 10

BSC6900

MAIO11

MAIO 11

BSC6900

MAIO12

MAIO 12

BSC6900

MAIO2

MAIO 2

BSC6900

MAIO3

MAIO 3

BSC6900

MAIO4

MAIO 4

BSC6900

MAIO5

MAIO 5

BSC6900

MAIO6

MAIO 6

BSC6900

MAIO7

MAIO 7

BSC6900

MAIO8

MAIO 8

BSC6900

MAIO9

MAIO 9

BSC6900

MAJORALMUP0

Feed Tri. 0 TMA Over


Critical Alarm Threshold

BSC6900

MAJORALMUP1

Feed Tri. 1 TMA Over


Critical Alarm Threshold

BSC6900

MAJORALMUP2

Feed Tri. 2 TMA Over


Critical Alarm Threshold

BSC6900

MAJORALMUP3

Feed Tri. 3 TMA Over


Critical Alarm Threshold

BSC6900

MAJORALMUP4

Feed Tri. 4 TMA Over


Critical Alarm Threshold

BSC6900

MAJORALMUP5

Feed Tri. 5 TMA Over


Critical Alarm Threshold

BSC6900

MANAME

MA Name

BSC6900

MANAME

MA Name

BSC6900

MASK

Subnet Mask

BSC6900

MASK

Subnet Mask

BSC6900

MASK

Subnet mask

BSC6900

MASK

IP Mask

BSC6900

MASK

Subnet mask

BSC6900

MASK

Subnet mask

BSC6900

MASK

Packet source mask

BSC6900

MASK

Subnet mask

BSC6900

MASK

Mask

BSC6900

MASTERIPADDR

Master Clock Server IP


Address

BSC6900

MASTERIPADDR

Clock Server IP Address 1 BSC6900

MAXADJPCVAL

MAX Up Adj. PC Value by


BSC6900
Qual.

MAXASSOCRETR

Association max retrans

MAXBW

Max bandwidth [64kbps] BSC6900

MAXCNTNUM

MAX Consecutive HO
Times

BSC6900

MaxDlAssRetryTimes

Retry Times of Downlink


TBF Reassignment

BSC6900

MaxDlEstRetryNum

Retry Times of Downlink


TBF Establishment

BSC6900

BSC6900

MAXDROPPWRTHRESHOL Max Drop Power


D
Threshold

BSC6900

MAXFQNUM

Maximum TRX Number

BSC6900

MAXFQNUM1

Maximum TRX Number

BSC6900

MAXFRAMELEN

Maximum Frame
Length[byte]

BSC6900

MAXLOADBTSNUM

Max BTS Num of Parallel


BSC6900
Software Load

MAXMFLEN

PPP mux max mux-frame


BSC6900
length

MAXMFLEN

PPP mux max mux-frame


BSC6900
length

MaxMissTimes

Maximum Retry Times

BSC6900

MAXNUM

Max Alarm Log Number

BSC6900

MAXOUTPUTPOWER

Diesel Max Output Power BSC6900

MAXPATHRETR

Path max retrans

BSC6900

MaxPbLinkChkNum

Pb Link Check Max


TimeOut Number

BSC6900

MAXPDCHNUM

Maximum Number of
PDCH

BSC6900

MAXPDCHRATE

Maximum Rate Threshold


BSC6900
of PDCHs in a Cell

MaxPollingRetryTimes

Retry Times of Downlink


TBF Polling

BSC6900

MAXPROMPTDATES

Expire Prompt Dates

BSC6900

MAXRECHARGECURRENT Charge Coefficient

BSC6900

MAXRECHARGECURRENT Charge Coefficient

BSC6900

MAXRESEND

Max Resend Times of


Phy.Info.

MAXRETRANS1

Max Retransmissions for


BSC6900
Radio Priority 1

MAXRETRANS2

Max Retransmissions for


BSC6900
Radio Priority 2

MAXRETRANS3

Max Retransmissions for


BSC6900
Radio Priority 3

MAXRETRANS4

Max Retransmissions for


BSC6900
Radio Priority 4

BSC6900

MAXSFLEN

PPP mux max sub-frame


BSC6900
length

MAXSFLEN

PPP mux max sub-frame


BSC6900
length

MAXSTEP0

MAX Down Adj.Value


Qual.Zone 0

BSC6900

MAXSTEP1

MAX Down Adj.Value


Qual.Zone 1

BSC6900

MAXSTEP2

MAX Down Adj.Value


Qual.Zone 2

BSC6900

MAXTA

Max TA

BSC6900

MAXTADROPCALLFILTER

MAX TA Drop Call Filter

BSC6900

MAXTADROPCALLSWITCH Max TA Drop Call Switch

BSC6900

MAXTADROPCALLTHRESH MAX TA Drop Call


OLD
Threshold

BSC6900

MAXTIME

Maximum time for


posave

MAXTSOCP

Maximum Number of
BSC6900
Occupied Abis Timeslots

MAXTTL

MAX TTL

MAXVALADJRX

MAX Up Adj. PC Value by


BSC6900
RX_LEV

MAXVALIDDATES

Maximum Valid Dates

BSC6900

MBFDCHKN

MBFD Check Index

BSC6900

MBFDLOCALIP

Multi hop BFD detect


local ip

BSC6900

BSC6900

BSC6900

MBR

Multi-band report

BSC6900

MBSIGNLEN

Filter Length for SDCCH


MEAN_BEP

BSC6900

MBTRAFFLEN

Filter Length for TCH


MEAN_BEP

BSC6900

MBTSID

Second BTS Index

BSC6900

MBTSNAME

Second BTS Name

BSC6900

MCC

MCC

BSC6900

MCC1

Cell MCC

BSC6900

MCCLASS

MC PRI Number

BSC6900

MCCLASS

MC PRI number

BSC6900

MCELLID

Second Cell Index

BSC6900

MCELLNAME

Second Cell Name

BSC6900

MCN

Cabinet No. of
Management Board

BSC6900

MCPAOPTALG

MCPA Optimization
Switch

BSC6900

MCSTANDARD

GSM Multi Carrier BTS


Standard

BSC6900

MDIDX

MD INDEX

BSC6900

MDLEVEL

MD Level

BSC6900

MDName

MD NAME

BSC6900

MDNAME

MD Name

BSC6900

MEASORDER

Allow MR Command or
not

BSC6900

MEASPERIOD

Measurement Period

BSC6900

MEASURETYPE

Measurement Report
Type

BSC6900

MEPID

MEP ID

BSC6900

MEPID

MEP ID

BSC6900

MEPTYPE

MEP Type

BSC6900

MHF

MP/MC List Head Option

BSC6900

MHF

MP/MC list head option

BSC6900

MINACCRXLEV

Cell Reselection Level


Threshold

BSC6900

MINBW

Min bandwidth [64kbps]

BSC6900

MINECNOTHRES

Min Ec/No threshold

BSC6900

MINOFFSET

Min Access Level Offset

BSC6900

MinorAlmThdA

ANT_A ALD Current Minor


BSC6900
Alarm Occur Threshold

MinorAlmThdB

ANT_B ALD Current Minor


BSC6900
Alarm Occur Threshold

MINORALMUP0

Feed Tri. 0 TMA Over


BSC6900
Warning Alarm Threshold

MINORALMUP1

Feed Tri. 1 TMA Over


BSC6900
Warning Alarm Threshold

MINORALMUP2

Feed Tri. 2 TMA Over


BSC6900
Warning Alarm Threshold

MINORALMUP3

Feed Tri. 3 TMA Over


BSC6900
Warning Alarm Threshold

MINORALMUP4

Feed Tri. 4 TMA Over


BSC6900
Warning Alarm Threshold

MINORALMUP5

Feed Tri. 5 TMA Over


BSC6900
Warning Alarm Threshold

MinorClrThdA

ANT_A ALD Current Minor


BSC6900
Alarm Clear Threshold

MinorClrThdB

ANT_B ALD Current Minor


BSC6900
Alarm Clear Threshold

MINPWRLEVDIRTRY

Min Power Level For


Directed Retry

BSC6900

MINRESTIMETCH

TCH Minimum Recovery


Time

BSC6900

MINRSCPTHRES

Min RSCP threshold

BSC6900

MINRXINT

Min interval of BFD


packet receive [ms]

BSC6900

MINRXINTERVAL

Minimum RX Interval

BSC6900

MINTXINT

Min interval of BFD


packet send [ms]

BSC6900

MINTXINTERVAL

Minimum TX Interval

BSC6900

MIRRORDPN

Mirror Dest Port No.

BSC6900

MIRRORSPN

Mirror Source Port No.

BSC6900

MIRRORTYPE

Mirror Type

BSC6900

MNC

MNC

BSC6900

MNC1

Cell MNC

BSC6900

MOCACCESSCPURATE

MOC Access CPU Rate

BSC6900

MODE

Signalling link mode

BSC6900

MODE

Check mode

BSC6900

MODE

System clock working


mode

BSC6900

MODE

Configure Mode

BSC6900

MODE

Mode after Switchover

BSC6900

MODE

File Output Mode

BSC6900

MODE

Backup mode

BSC6900

MODE0

Feed Tri. 0 Alarm Mode

BSC6900

MODE1

Feed Tri. 1 Alarm Mode

BSC6900

MODE2

Feed Tri. 2 Alarm Mode

BSC6900

MODE3

Feed Tri. 3 Alarm Mode

BSC6900

MODE4

Feed Tri. 4 Alarm Mode

BSC6900

MODE5

Feed Tri. 5 Alarm Mode

BSC6900

MONITORPERIOD

Monitor Period

BSC6900

MONITORTIME

Monitor Time

BSC6900

Month

Month

BSC6900

MOVESPEEDTHRES

Quick Move Speed


Threshold

BSC6900

MPGRPEAAT

MP Group Frame Error


Alarm Threshold

BSC6900

MPGRPEADT

MP Group Frame Error


Alarm Clearance
Threshold

BSC6900

MPGRPN

MLPPP Group No.

BSC6900

MPGRPN

MP Group No.

BSC6900

MPGRPN

MP Group No.

BSC6900

MPMODE

Multiplexing Mode

BSC6900

MPN

Connect Port No.

BSC6900

MPSWITCH

MCPPP Switch

BSC6900

MPTYPE

MP type

BSC6900

MPUSLOT

MPU Slot No.

BSC6900

MPUSUBRACK

MPU Subrack No.

BSC6900

MRCOMPREG

MR. Compensation
Allowed

BSC6900

MRMISSCOUNT

Allowed MR Number Lost BSC6900

MRMISSNUM

MRMissNumber

BSC6900

MRPREPROCFREQ

Sent Freq.of
preprocessed MR

BSC6900

MRRUATTENFACTOR1

Antenna Tributary 1
Factor

BSC6900

MRRUATTENFACTOR2

Antenna Tributary 2
Factor

BSC6900

MRSCOPESWITCH

MR Collection Scope
Switch

BSC6900

MRSWITCH

MR Collection Control
Switch

BSC6900

MRU

Max Receive Unit

BSC6900

MS

Number of MSs

BSC6900

MSCAPABLESTATSWITCH

MS Capability Statistic
Switch

BSC6900

MSCCAP

MSC Available
Capability<K User
number>

BSC6900

MSCNRILEN

Length of NRI in TMSI

BSC6900

MSCNULLNRI

MSC NULL-NRI Value

BSC6900

MSCPOOLALLOW

MSC Pool Function


Enabled

MSCSTATUE

MSC Administrable State BSC6900

MSCVER

MSC Version Indication

BSC6900

MSIPFAILINDDELAY

TREESTABLISH

BSC6900

MSISDN

MSISDN

BSC6900

MSISDNPREFIX1

MSISDN prefix 1

BSC6900

MSISDNPREFIX2

MSISDN prefix 2

BSC6900

MSISDNPREFIX3

MSISDN prefix 3

BSC6900

BSC6900

MSISDNPREFIX4

MSISDN prefix 4

BSC6900

MSISDNPREFIX5

MSISDN prefix 5

BSC6900

MsisdnPrfxList2StartBscLs
Prefix Number for BSC 1
1

BSC6900

MsisdnPrfxList2StartBscLs
Prefix Number for BSC 10 BSC6900
10

MsisdnPrfxList2StartBscLs
Prefix Number for BSC 2
2

BSC6900

MsisdnPrfxList2StartBscLs
Prefix Number for BSC 3
3

BSC6900

MsisdnPrfxList2StartBscLs
Prefix Number for BSC 4
4

BSC6900

MsisdnPrfxList2StartBscLs
Prefix Number for BSC 5
5

BSC6900

MsisdnPrfxList2StartBscLs
Prefix Number for BSC 6
6

BSC6900

MsisdnPrfxList2StartBscLs
Prefix Number for BSC 7
7

BSC6900

MsisdnPrfxList2StartBscLs
Prefix Number for BSC 8
8

BSC6900

MsisdnPrfxList2StartBscLs
Prefix Number for BSC 9
9

BSC6900

MsisdnPrfxList2StartBtsLs
Prefix Number for BTS 1
1

BSC6900

MsisdnPrfxList2StartBtsLs
Prefix Number for BTS 10 BSC6900
10

MsisdnPrfxList2StartBtsLs
Prefix Number for BTS 2
2

BSC6900

MsisdnPrfxList2StartBtsLs
Prefix Number for BTS 3
3

BSC6900

MsisdnPrfxList2StartBtsLs
Prefix Number for BTS 4
4

BSC6900

MsisdnPrfxList2StartBtsLs
Prefix Number for BTS 5
5

BSC6900

MsisdnPrfxList2StartBtsLs
Prefix Number for BTS 6
6

BSC6900

MsisdnPrfxList2StartBtsLs
Prefix Number for BTS 7
7

BSC6900

MsisdnPrfxList2StartBtsLs
Prefix Number for BTS 8
8

BSC6900

MsisdnPrfxList2StartBtsLs
Prefix Number for BTS 9
9

BSC6900

MsisdnSegList2AvoidBscL
Avoid Number for BSC 1
s1

BSC6900

MsisdnSegList2AvoidBscL
Avoid Number for BSC 10 BSC6900
s10
MsisdnSegList2AvoidBscL
Avoid Number for BSC 2
s2

BSC6900

MsisdnSegList2AvoidBscL
Avoid Number for BSC 3
s3

BSC6900

MsisdnSegList2AvoidBscL
Avoid Number for BSC 4
s4

BSC6900

MsisdnSegList2AvoidBscL
Avoid Number for BSC 5
s5

BSC6900

MsisdnSegList2AvoidBscL
Avoid Number for BSC 6
s6

BSC6900

MsisdnSegList2AvoidBscL
Avoid Number for BSC 7
s7

BSC6900

MsisdnSegList2AvoidBscL
Avoid Number for BSC 8
s8

BSC6900

MsisdnSegList2AvoidBscL
Avoid Number for BSC 9
s9

BSC6900

MsisdnSegList2AvoidBtsLs
Avoid Number for BTS 1
1

BSC6900

MsisdnSegList2AvoidBtsLs
Avoid Number for BTS 10 BSC6900
10
MsisdnSegList2AvoidBtsLs
Avoid Number for BTS 2
2

BSC6900

MsisdnSegList2AvoidBtsLs
Avoid Number for BTS 3
3

BSC6900

MsisdnSegList2AvoidBtsLs
Avoid Number for BTS 4
4

BSC6900

MsisdnSegList2AvoidBtsLs
Avoid Number for BTS 5
5

BSC6900

MsisdnSegList2AvoidBtsLs
Avoid Number for BTS 6
6

BSC6900

MsisdnSegList2AvoidBtsLs
Avoid Number for BTS 7
7

BSC6900

MsisdnSegList2AvoidBtsLs
Avoid Number for BTS 8
8

BSC6900

MsisdnSegList2AvoidBtsLs
Avoid Number for BTS 9
9

BSC6900

MSLEVSTRQPBGT

EN Quick PBGT HO ALG


When MS Leaves BTS

BSC6900

MSMAXRETRAN

MS MAX Retrans

BSC6900

MSPCMD

MSP Control Command

BSC6900

MSRDMCSLEV

MSRD MCS Threshold

BSC6900

MSRDPDCHLEV

MSRD PDCH Multiplex


Threshold

BSC6900

MSRN

Subrack No. of
Management Board

BSC6900

MSRXMIN

Min DL level on
candidate Cell

BSC6900

MSRXQUALSTATTHRSH

MS Rx Quality Statistic
Threshold

BSC6900

MSTF

MS Flow Control Timer

BSC6900

MSTSERVACTDELAY

Master Service Active


Delay

BSC6900

MSTXPWRMAX

Maximum TX Power for


Access PCH

BSC6900

MSW

Self-healing Switch for


Memory Overload

BSC6900

MTCACCESSCPURATE

MTC Access CPU Rate

BSC6900

MTHD

Method

BSC6900

MTP2LNKN

MTP2 link No.

BSC6900

MTRLGY

Metrology

BSC6900

MTU

MTU value

BSC6900

MTU

MTU

BSC6900

MTU

MTU[Byte]

BSC6900

MTVT

Hierarchical Power
Supply Para.<0.1v>

BSC6900

MULTIBANDREP

Multi-Band Report

BSC6900

MUTECHECKCLASS1PERIO Period of Mute Detect


D
Class1

BSC6900

MUTECHECKCLASS2SWIT Mute Detect Class2


CH
Switch

BSC6900

MUTECHECKPEIROD

Period of Mute Detect


Class2

MUTEFORBITCALLTMINTVA Access Prohibited Upon


L
One-Way Audio

BSC6900

BSC6900

MUTERELCALLEN

Forced Call Release Upon


Failed Handover in One- BSC6900
Way Audio

MUXTIME

PPP mux framing outtime[us]

BSC6900

MUXTIME

PPP mux framing outtime[us]

BSC6900

MUXTYPE

IP MUX Type

BSC6900

MWTRXNO

Min Quantity of Working


TRXs

BSC6900

MYDISCRIMINATOR

My discriminator of BFD

BSC6900

N200

N200

BSC6900

N200ESTAB

N200 of Establish

BSC6900

N200FFULL

N200 of FACCH/Full Rate

BSC6900

N200FHALF

N200 of FACCH/Half Rate BSC6900

N200PARASWITCH

Use LAPDm N200

BSC6900

N200REL

N200 of Release

BSC6900

N200SACCH

N200 of SACCH

BSC6900

N200SDCCH

N200 of SDCCH

BSC6900

N3101

Maximum Value of
N3101

BSC6900

N3103

Maximum Value of
N3103

BSC6900

N3105

Maximum Value of
N3105

BSC6900

N391

Parameter of DTE [N391] BSC6900

N392

Parameter of DTE [N392] BSC6900

N393

Parameter of DTE [N393] BSC6900

NACCSPT

Support NACC

BSC6900

NAME

OSP name

BSC6900

NAME

DSP name

BSC6900

NAME

Signalling Route name

BSC6900

NAME

Signalling link set name

BSC6900

NAME

Signalling link name

BSC6900

NAME

Local entity name

BSC6900

NAME

Destination entity name

BSC6900

NAME

M3UA route name

BSC6900

NAME

M3UA Signalling link set


name

BSC6900

NAME

M3UA Signaling link


name

BSC6900

NAME

PCU Name

BSC6900

NAME

Adjacent Node Name

BSC6900

NAMRLFRMTRXALLOWED

Assign Non-AMR User


Loose Fre. Reuse TRX

BSC6900

NAVGI

N_AVG_I

BSC6900

NBAMRTFOSWITCH

TFO Switch

BSC6900

NBR2GNCELL1ID

Neighbor 2G Cell 1 Index BSC6900

NBR2GNCELL1NAME

Neighbor 2G Cell 1 Name BSC6900

NBR2GNCELL2ID

Neighbor 2G Cell 2 Index BSC6900

NBR2GNCELL2NAME

Neighbor 2G Cell 2 Name BSC6900

NBR2GNCELLID

Neighbor 2G Cell Index

BSC6900

NBR2GNCELLNAME

Neighbor 2G Cell Name

BSC6900

NBR3GNCELLID

Neighbor Cell Index

BSC6900

NBR3GNCELLNAME

Neighbor Cell Name

BSC6900

NBRCELLSWITCH

Neighbor Cell Plan


Switch

BSC6900

NBRCI

Neighbour Cell CI

BSC6900

NBRLAC

Neighbour Cell LAC

BSC6900

NBRMCC

Neighbour Cell MCC

BSC6900

NBRMNC

Neighbour Cell MNC

BSC6900

NBRSPT64

Support 64 Neighbour
Cells

BSC6900

NC2LoadResel

NC2 Load Reselection


Switch

BSC6900

NC2SPT

Support NC2

BSC6900

NCC

NCC

BSC6900

NCC

NCC

BSC6900

NCCPERMIT

NCC Permitted

BSC6900

NCCPERMITED

NCC Permitted

BSC6900

NCELLFILTER

Neighbor Cell Filter


Length MR Number

BSC6900

NCELLFLTLEN

Filter Length for Ncell


RX_LEV

BSC6900

NcellInterFLevelThres0

NeighborCell Interfere
Level Thresh 0

BSC6900

NcellInterFLevelThres1

NeighborCell Interfere
Level Thresh 1

BSC6900

NcellInterFLevelThres2

NeighborCell Interfere
Level Thresh 2

BSC6900

NcellInterFLevelThres3

NeighborCell Interfere
Level Thresh 3

BSC6900

NcellInterFLevelThres4

NeighborCell Interfere
Level Thresh 4

BSC6900

NcellInterFLevelThres5

NeighborCell Interfere
Level Thresh 5

BSC6900

NcellInterFLevelThres6

NeighborCell Interfere
Level Thresh 6

BSC6900

NcellInterFLevelThres7

NeighborCell Interfere
Level Thresh 7

BSC6900

NCHOCBLOCKNUM

NCH Occupy Block


Number

BSC6900

NCHSTARTBLOCK

NCH Start Block

BSC6900

NCO

Network Control Mode

BSC6900

NEIGHBOR

Adjacent flag

BSC6900

NETMASK

Net Mask

BSC6900

NEWURGHOMININTV

Min Interval for Emerg.


HO

BSC6900

NEXTHOP

Forward Route Address

BSC6900

NEXTHOP

Forward Route Address

BSC6900

NEXTHOP

Forward route address

BSC6900

NEXTHOP

Forward route address

BSC6900

NI

Network ID

BSC6900

NM

Download file name

BSC6900

NMO

Network Operation Mode BSC6900

NMSACN

No Mains Supply Alarm


Cabinet No.

BSC6900

NMSAPN

No Mains Supply Alarm


Port No.

BSC6900

NMSASN

No Mains Supply Alarm


Slot No.

BSC6900

NMSASRN

No Mains Supply Alarm


Subrack No.

BSC6900

NO1M48ALMTHDDOWN

Lower limit of No.1 input


BSC6900
-48V[-V]

NO1M48ALMTHDUP

Upper limit of No.1 input


BSC6900
-48V[-V]

NO2M48ALMTHDDOWN

Lower limit of No.2 input


BSC6900
-48V[-V]

NO2M48ALMTHDUP

Upper limit of No.2 input


BSC6900
-48V[-V]

NO3M48ALMTHDDOWN

Lower limit of No.3 input


BSC6900
-48V[-V]

NO3M48ALMTHDUP

Upper limit of No.3 input


BSC6900
-48V[-V]

NO4M48ALMTHDDOWN

Lower limit of No.4 input


BSC6900
-48V[-V]

NO4M48ALMTHDUP

Upper limit of No.4 input


BSC6900
-48V[-V]

NO5M48ALMTHDDOWN

Lower limit of No.5 input


BSC6900
-48V[-V]

NO5M48ALMTHDUP

Upper limit of No.5 input


BSC6900
-48V[-V]

NO6M48ALMTHDDOWN

Lower limit of No.6 input


BSC6900
-48V[-V]

NO6M48ALMTHDUP

Upper limit of No.6 input


BSC6900
-48V[-V]

NOAMRFULLTOHALFHOAL
Non-AMR F-H Ho Allowed BSC6900
LOW

NOAMRFULLTOHALFHOAT Non-AMR F-H Ho ATCB


CBADJSTEP
Adjust Step

BSC6900

NOAMRFULLTOHALFHOAT Non-AMR F-H Ho ATCB


CBTHRESH
Threshold

BSC6900

NOAMRFULLTOHALFHOPA Non-AMR F-H Ho Pathloss


BSC6900
THADJSTEP
Adjust Step

NOAMRFULLTOHALFHOPA Non-AMR F-H Ho Pathloss


BSC6900
THTHRESH
Threshold

NOAMRFULLTOHALFHOQU Non-AMR F-H Ho Qual.


ALTHRESH
Threshold

BSC6900

NOAMRFULLTOHALFTHRE Non-AMR F-H Traffic


SH
Threshold

BSC6900

NOAMRHALFTOFULLHOAT Non-AMR H-F Ho ATCB


CBTHRESH
Threshold

BSC6900

NOAMRHALFTOFULLHOPA Non-AMR H-F Ho Pathloss


BSC6900
THTHRESH
Threshold

NOAMRHALFTOFULLHOQ
UALALLOW

Allow Non-AMR H-F


Quality-based HO

BSC6900

NOAMRHALFTOFULLHOQ
UALTHRESH

Non-AMR H-F Ho Qual.


Threshold

BSC6900

NOAMRHALFTOFULLTHRE Non-AMR H-F Traffic


SH
Threshold

BSC6900

NODET

Adjacent Node Type

BSC6900

NODLMRHOALLOWLIMIT

Cons.No Dl Mr.HO
Allowed Limit

BSC6900

NODLMRHOEN

No Dl Mr.HO Allowed

BSC6900

NODLMRHOQUALLIMIT

No Dl Mr.Ul Qual HO
Limit

BSC6900

NOMINALCAPACITY

Norminal Capacity{AH}

BSC6900

NONAMRCALLPCALLOWE
D

Allow III Power Control


For Non-AMR

BSC6900

NONDRXPERIOD

Non-DRX Period

BSC6900

NormalCurDurA

A ALD Cur-Minor Alarm


N-Cur Duration

BSC6900

NormalCurDurB

B ALD Cur-Minor Alarm


N-Cur Duration

BSC6900

NORMALRESELALLOW

Cell Normal Reselection


Allowed

BSC6900

NORTHD

Normal Work TEMP


Threshold

BSC6900

NOTMSIALLCELLPAGINGLI Discard TMSI All Cell


MITFLAG
Paging

BSC6900

NOTRASP

Statistical Period of Notraffic

BSC6900

NOVGCSTIME

No VGCS Call Time

BSC6900

NQUERIES

Number of TRACERT
Packages Per TTL

BSC6900

NRBSDCCHFFLEN

Filter Length for SDCCH


NBR_RCVD_BLOCK

BSC6900

NRBTCHFFLEN

Filter Length for TCH


NBR_RCVD_BLOCK

BSC6900

NRI

NRI Value

BSC6900

NRI

NRI Value

BSC6900

NRofFDDCellFlag

Support NR_of_FDD_cells
BSC6900
Writing

NSEI

NSE Identifier

BSC6900

NSEI

NSE Identifier

BSC6900

NSIGSTRFLTLEN

NCell Filter Length for


SDCCH Level

BSC6900

NSLATI

NS Latitude

BSC6900

NSVCI

NSVC Identifier

BSC6900

NSVCIDX

NSVC Index

BSC6900

NTDI

Normal Temperature
Delta Tin

BSC6900

NTDO

Normal Temperature
Delta Tout

BSC6900

NY2

Ny2

BSC6900

OAMFLOWBW

OAM flow min


bandwidth[%]

BSC6900

OAMFLOWBW

OAM flow min


bandwidth[%]

BSC6900

OAMFLOWBW

OAM flow min


bandwidth[%]

BSC6900

OAMFLOWBW

OAM flow min


bandwidth[%]

BSC6900

OAMFLOWBW

OAM flow min


bandwidth[%]

BSC6900

OAMFLOWDSCP

DSCP of OAM flow

BSC6900

OAMMINBWKEY

OAM flow min bandwidth


BSC6900
switch

OBJECTTYPE

Object Type

BSC6900

OBJECTTYPE

Operate Object

BSC6900

OBJIDX

Object Index

BSC6900

OBJIDX

User Index

BSC6900

OBJTP

Object Type

BSC6900

OBJTP

Object Type

BSC6900

OBJTYPE

Object Type

BSC6900

OccupyStreamingSwitch

Preempt Switch of
Streaming Resource

BSC6900

OLTOULHOALLOW

OL to UL HO Allowed

BSC6900

OMLBKUP

Configure Backup OML

BSC6900

OMLDETECTSWITCH

OML Detection Switch

BSC6900

OmlDetectTime

OML Lapd Link Detect


Time

BSC6900

OMLDSCP

OML DSCP

BSC6900

OMLESLDL

BTS OML&ESL Average


Down-bandwidth

BSC6900

OMLESLUL

BTS OML&ESL Average


Up-bandwidth

BSC6900

OMLPRI

OML Priority

BSC6900

OMLSP

OML Service PRI

BSC6900

OMLVLANID

OML VlanId

BSC6900

OMLWS

OML/ESL/EML LAPD
Downlink Window Size

BSC6900

OMUIP

OMU External Network


Virtual IP

BSC6900

OMUMASK

OMU External Network


Mask

BSC6900

OP

Operator

BSC6900

OPC

OSP Code

BSC6900

OPC

OSP Code

BSC6900

OPCIDX

OPC Index

BSC6900

OperatorType

Operator Type

BSC6900

OPINDEX

Operator Index

BSC6900

OPINDEXSET

OP INDEX SET

BSC6900

OPMODE

Operation Mode

BSC6900

OPMODE

Operation Mode

BSC6900

OPMODE

Operation Mode

BSC6900

OPMODE

Operate mode

BSC6900

OPMODE

Operation Mode

BSC6900

OPNAME

Operator Name

BSC6900

OPTILAYER

Assign Optimum Layer

BSC6900

OPTILEVTHRES

Assign-optimum-level
Threshold

BSC6900

OPTITATHRES

TA Threshold of
Assignment Pref

BSC6900

OPTL

TRX Priority

BSC6900

OPTM

Optical interface
standard

BSC6900

OPTP

Operation Type

BSC6900

OPTYPE

Operate Type

BSC6900

OPX

OPX

BSC6900

ORIPORT

Originally E1/T1 Port No. BSC6900

OT

Operation type

BSC6900

OTHERFREQ

Other Frequency

BSC6900

OTHMODNUM

Number of Other-RAT
Modules

BSC6900

OTOURECEIVETH

OtoU HO Received Level


BSC6900
Threshold

OUTASSOPTEN

UL Subcell Assignment
Optimization

BSC6900

OUTBSCHOCLEARTIMER

T8

BSC6900

OUTBSCHOCMDTIMER

T7

BSC6900

OutBscLoadHoEn

Inter BSC Load


Information Allowed

BSC6900

OUTGENOVERLDTHRED

UL Subcell General
Overload Threshold

OUTHOPWROVERLOADTH Power Overload


RESHOLD
Threshold In Ho. Out

BSC6900

BSC6900

OUTINNREXLEVTHRED

Outgoing OL Subcell HO
Level TH

BSC6900

OUTLOADHOENABLE

Load HO Allowed

BSC6900

OUTLOADHOMODPERI

MOD Step LEN of UL


Load HO Period

BSC6900

OUTLOADHOPERIOD

UL Subcell Load
Hierarchical HO Periods

BSC6900

OUTLOADHOSTEP

Step Length of UL
Subcell Load HO

BSC6900

OUTLOWLOADTHRED

UL Subcell Lower Load


Threshold

BSC6900

OUTMASK

Out BSC Mask

BSC6900

OUTPN

Out BSC Port No.

BSC6900

OUTPORTNO

DXX Out Port No.

BSC6900

OUTPORTTS

DXX Out Time Slot No.

BSC6900

OUTPUT0

Cannel 0 Digital Control


Signal Level

BSC6900

OUTPUT1

Cannel 1 Digital Control


Signal Level

BSC6900

OUTPUT2

Cannel 2 Digital Control


Signal Level

BSC6900

OUTPUT3

Cannel 3 Digital Control


Signal Level

BSC6900

OUTPUTPOWER

Output Power

BSC6900

OUTPUTPOWER1

Output Power

BSC6900

OUTPUTPOWERUNIT

Output Power Unit

BSC6900

OUTSERIOVERLDTHRED

UL Subcell Serious
Overload Threshold

BSC6900

OUTSERVICEALM

Cell Out-of-Service Alarm


BSC6900
Switch

OUTSN

Load Outlet Slot No.

BSC6900

OUTSN

Out BSC Slot No.

BSC6900

OUTSRN

Out BSC Subrack No.

BSC6900

OutSysLoadHoEn

Allow Inter-RAT Load HO


in Connect State

BSC6900

OUTSYSSERVHOREASSIG
NEN

Service Handover
Reassign

BSC6900

OUTSYSSERVICEHOEN

Service Based Handover


BSC6900
Switch

OUTTIMER

Load Info Timeout Timer

BSC6900

OUTTSN

Out BSC Start Timeslot


No.

BSC6900

OverCurAlmThdA

ANT_A ALD Over Current


BSC6900
Occur Threshold

OverCurAlmThdB

ANT_B ALD Over Current


BSC6900
Occur Threshold

OverCurAlmThdRET

RET ALD Over Current


Occur Threshold

OverCurClrThdA

ANT_A ALD Over Current


BSC6900
Clear Threshold

BSC6900

OverCurClrThdB

ANT_B ALD Over Current


BSC6900
Clear Threshold

OverCurClrThdRET

RET ALD Over Current


Clear Threshold

BSC6900

OverCurDurA

A ALD Cur-Minor Alarm


Over-Cur Duration

BSC6900

OverCurDurB

B ALD Cur-Minor Alarm


Over-Cur Duration

BSC6900

OVERLOADINTV

Overload Indication
Period

BSC6900

OVERTHD

Derating TEMP Threshold BSC6900

P11

CPU Usage for Critical


Paging FC

BSC6900

P12

CPU Usage for Major


Paging FC

BSC6900

P13

CPU Usage for Minor


Paging FC

BSC6900

P14

CPU Usage for Slight


Paging FC

BSC6900

PaAdjVol

PA Intelligent Adjust
Voltage

BSC6900

PACKASSDLSHIFT

Move Packet Assignment


BSC6900
Down to BTS

PAGINGAVGCAPACITYINPE Average Paging Message


BSC6900
RIOD
Number In Period

PAGINGLIFETIME

BTS Paging Lifetime

BSC6900

PAGINGMAXCAPACITYINPE MAX Paging Message


RIOD
Number In Period

BSC6900

PAGTIMES

Paging Times

BSC6900

PANDEC

PAN_DEC

BSC6900

PANINC

PAN_INC

BSC6900

PANMAX

PAN_MAX

BSC6900

PAOPTILEVEL

Priority of Shut Down


TRX

BSC6900

PatchNo

Patch No.

BSC6900

PatchNo1

Patch Number

BSC6900

PATHCHK

IP path check flag

BSC6900

PATHID

IP path ID

BSC6900

PATHID

IP path ID

BSC6900

PATHLOSS

Path Loss of Different


Frequency Band

BSC6900

PATHLOSSHOEN

Pathloss Ho. Enable

BSC6900

PATHT

IP path type

BSC6900

PATTYPE

Patch type

BSC6900

PB

Pb

BSC6900

PBGTHOEN

PBGT HO Allowed

BSC6900

PBGTLAST

PBGT Valid Time

BSC6900

PBGTMARGIN

PBGT HO Threshold

BSC6900

PBGTSTAT

PBGT Watch Time

BSC6900

PbMtnMsgReSend

MAX Retrans
BSC6900
Maintenance Msg on Pb-I

PCADJPERIOD

PC Interval

BSC6900

PCMEASCHAN

PC_MEAS_CHAN

BSC6900

PCU

PCU No

BSC6900

PCUINDEX

PCU No.

BSC6900

PCUNO

PCU No.

BSC6900

PCUNO

PCU No.

BSC6900

PCUPREEMPTFLAG

PCU Support
PREEMPT_ABIS_LINK
Message

BSC6900

PDCHDWNLEV

PDCH Downlink Multiplex


BSC6900
Threshold

PDCHPWRSAVEN

PDCH Power Saving


Enable

BSC6900

PDCHREFORMING

PDCH Reforming

BSC6900

PDCHUPLEV

PDCH Uplink Multiplex


Threshold

BSC6900

PDTMRVALUE

PENDING timer

BSC6900

PEERBSCID

Peer BSC ID

BSC6900

PeerBSCID

Peer BSC ID

BSC6900

PEERBSCIP

Peer BSC IP

BSC6900

PEERBSCMASK

Peer BSC Mask

BSC6900

PEERBTSID

Peer BTS ID

BSC6900

PEERIP

Peer IP Address

BSC6900

PEERIP

Peer IP Address

BSC6900

PEERIP

Peer IP address

BSC6900

PEERIP

Peer IP address

BSC6900

PEERIP

Peer IP address

BSC6900

PEERIP1

First destination IP
address

BSC6900

PEERIP2

Second destination IP
address

BSC6900

PEERIPADDR

Peer IP address

BSC6900

PEERMASK

Peer subnet mask

BSC6900

PEERPN

Destination SCTP port


No.

BSC6900

PEERVERSION

Peer Version

BSC6900

PENALTYEN

Penalty Allowed

BSC6900

PENALTYLASTTM

Cell Penalty Duration

BSC6900

PENALTYRXLEV

Cell Penalty Level

BSC6900

PENALTYTIMER

CfgPenaltyTimer

BSC6900

PERIOD

Measurement Period

BSC6900

PERIOD

Ping Check Period

BSC6900

PFC

Support Protocol Field


Compress

BSC6900

PFC

Protocal field compress

BSC6900

PFC

Protocol field compress

BSC6900

PFCSUP

PFC Support

BSC6900

PGCLASSIFINGALLOWED

Paging Message
Classifying Allowed

BSC6900

Max CS Paging Message


Num in Period

BSC6900

PGMAXPSMSGNUMINPERI Max PS Paging Message


OD
Num in Period

BSC6900

PGSTATPERIOD

Paging Statistical Period

BSC6900

PHB

PHB

BSC6900

PHB

Per-Hop Behavior

BSC6900

PGMAXMSGNUMINPERIOD

PI

Cell Reselect Parameters


BSC6900
Indication

PKPEnableSta

Private Key Password


Enabled State

BSC6900

PKTCOUNT

PKT Count

BSC6900

PKTLEN

PKT Size[Byte]

BSC6900

PKTLEN

Packet Length

BSC6900

PKTLENTHRES

Maximum Frame Length

BSC6900

PKTSI

PACKET SI

BSC6900

PKTSIZE

PKT Size

BSC6900

PKTSIZE

Size of packet

BSC6900

PL1

Persistence Level 1

BSC6900

PL16QAM

16QAM Transmitter
Power Reduce Level

BSC6900

PL2

Persistence Level 2

BSC6900

PL3

Persistence Level 3

BSC6900

PL32QAM

32QAM Transmitter
Power Reduce Level

BSC6900

PL4

Persistence Level 4

BSC6900

PL8PSK

TRX 8PSK Level

BSC6900

PLPRD

Packet lost measure


period [100ms]

BSC6900

PLTH

Packet discard
threshold[0.001]

BSC6900

PLYPOINT

Play Point

BSC6900

PLYSWITCH

Play Switch

BSC6900

PLYTIME

Play Time

BSC6900

PMCTHD

Performance monitor
control threshold

BSC6900

PMCTHD

Performance monitor
control threshold

BSC6900

PMI

Interval for Sending Cell


Paging Package

BSC6900

PMNUM

Number of Cell Pagings


in One Package

BSC6900

PMOAFLAG

Cell Paging Package


Switch

BSC6900

PMRTHD

Performance monitor
restore threshold

BSC6900

PMRTHD

Performance monitor
restore threshold

BSC6900

PMSW

Performance monitoring
flow control switch

BSC6900

PN

Port No

BSC6900

PN

Port No

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

BM Port No

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Physics port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

PN

Port No.

BSC6900

POCDELAY

Transmission Delay of
POC Service

BSC6900

POCGBRMAX

Max. GBR for POC


Service

POCGBRMIN

Min. GBR for POC Service BSC6900

PocSup

POC Support

BSC6900

PODECTHRES

Power Output Reduction


Threshold

BSC6900

POERRTHRES

Power Output Error


Threshold

BSC6900

POINTDESINFO

Rollback Point
Description

BSC6900

POINTNAME

Rollback Point Name

BSC6900

Port

Destination Port

BSC6900

PORT

Port

BSC6900

BSC6900

PORT

Port

BSC6900

PORTNO

DXX In Port No.

BSC6900

PORTNUM

DXX Port Number

BSC6900

PORTPROTYPE

Port protocol type

BSC6900

PortSwitch

Panel Port Switch

BSC6900

PORTTYPE

Port Type

BSC6900

PORTTYPE

Port Type

BSC6900

POS2QUATER

2Quater Message
Transmission Channel

BSC6900

POT

Patch Operation Type

BSC6900

POWER

Rated Power

BSC6900

POWER_RELAY1

Switch for Relay 1

BSC6900

POWER_RELAY2

Switch for Relay 2

BSC6900

POWER_RELAY3

Switch for Relay 3

BSC6900

POWER_RELAY4

Switch for Relay 4

BSC6900

POWER_RELAY5

Switch for Relay 5

BSC6900

POWER_RELAY6

Switch for Relay 6

BSC6900

POWERCURRENTDIV

Battery Shunt Coefficient BSC6900

POWERREDUCE16QAM

16QAM Transmitter
Power Reduce Level

BSC6900

POWERREDUCE32QAM

32QAM Transmitter
Power Reduce Level

BSC6900

POWERTYPE

Power Type

BSC6900

POWERTYPE

Cabinet Power System


Type

BSC6900

POWL

Power Level

BSC6900

POWT

Power Type

BSC6900

PPPEAAT

PPP Frame Error Alarm


Threshold

BSC6900

PPPEADT

PPP Frame Error Alarm


Clearance Threshold

BSC6900

PPPLNKN

PPP Link No.

BSC6900

PPPLNKN

PPP link No.

BSC6900

PPPLNKN

PPP sub-link No.

BSC6900

PPPLNKN

PPP link No.

BSC6900

PPPMUX

PPP mux

BSC6900

PQNUM

Priority queue number

BSC6900

PREEMFORHONOTREL

Preempted Call Not


Released After Handover BSC6900
Failure

PREEMFORHOPDCH

PDCH Preemption
Allowed During Handover BSC6900
Due to Preemption

PREEMPTIONPERMIT

Emergency Call
Preemption Permitted

BSC6900

PREMRSAMPLE

Preprocess MR Sample
Ratio

BSC6900

PRI

Route Priority

BSC6900

PRIACCTHR

Packet Access Priority

BSC6900

PRIFCEN

Support Priority Based


Flow Control

BSC6900

PRIMMESPPT

Transfer Original MR

BSC6900

PRINTCTHD

Print control threshold

BSC6900

PRINTCTHD

Print control threshold

BSC6900

PRINTRTHD

Print restore threshold

BSC6900

PRINTRTHD

Print restore threshold

BSC6900

PRINTSW

Print Flow control switch

BSC6900

PRIOR

Cell Priority

BSC6900

PRIOR

Cell Priority

BSC6900

PRIORABISLOADTHRED

Flex Abis Prior Choose


Load Thred

BSC6900

PRIORCLASS

Cell HCS Prior Class

BSC6900

PRIORITY

Route priority

BSC6900

PRIORITY

Signalling link priority

BSC6900

PRIORITY

Priority

BSC6900

PRIVATEPROBEFST

Preferential Customized
Detection Type

BSC6900

PRIVATEPROBENUM

Number of Customized
Detection Types

BSC6900

PRIVATEPROBESND

Subsidiary Customized
Detection Type

BSC6900

PrivKey

Private Key File Name

BSC6900

PROBESEQ

BTS Port Detection


Sequence

BSC6900

PROT

SS7 protocol type

BSC6900

PROT

Frame Relay Protocol


Type

BSC6900

PROTECTDELAYTIME

Protection Delay for


Detection

BSC6900

PROTECTTIME

Dyn. Turning Off Cell


Protection Time

BSC6900

ProtectTimeTrxPowerOn

TRX Power-on Protection


BSC6900
Time

PS

Port select

BSC6900

PS

Port select

BSC6900

PS

Port select

BSC6900

PSCHRABIS

PS CHR Abis

BSC6900

PSCHRGB

PS CHR Gb

BSC6900

PSCHRINNINFO

PS CHR Inner Information BSC6900

PSCHRINNMSG

PS CHR Inner Message

BSC6900

PSCHRUM

PS CHR Um

BSC6900

PSDATADL

GSM PS data service


downlink factor

BSC6900

PSDATAUL

GSM PS data service


uplink factor

BSC6900

PSHOSUP

PS Handover Support

BSC6900

PSHPRIDATAPATH

PS high PRI data path

BSC6900

PSHPRIDATAPRI

PS high PRI data priority

BSC6900

PSHPSP

PS High PRI Service PRI

BSC6900

PSI1RPT

PSI1 Repetition Period

BSC6900

PSISTATUSIND

Support PSI Status


Message

BSC6900

PSLPRIDATAPATH

PS low PRI data path

BSC6900

PSLPRIDATAPRI

PS low PRI data priority

BSC6900

PSLPSVP

PS Low PRI Service PRI

BSC6900

PSOTOURECEIVETHRSH

PS OtoU HO Receive
Level Threshold

BSC6900

PSOUTMODE

Mode Control

BSC6900

PSRACHACCLEV

PS RACH Min. Access


Level

BSC6900

PSRACJACCLEV

PS Min.Access Level

BSC6900

PSRCDSW

PS CHR Switch

BSC6900

PSRESREQMSGNUMINPER Max PS Resource REQ


IOD
Num in Period

BSC6900

PSRESREQSTATPERIOD

PS Resource REQ
Statistical Period

BSC6900

PSU0

DPSU 0 Configured

BSC6900

PSU1

DPSU 1 Configured

BSC6900

PSU2

DPSU 2 Configured

BSC6900

PSU2

DPSU 2 Configured

BSC6900

PSU3

DPSU 3 Configured

BSC6900

PSU4

DPSU 4 Configured

BSC6900

PSU5

DPSU 5 Configured

BSC6900

PSU6

DPSU 6 Configured

BSC6900

PSU7

DPSU 7 Configured

BSC6900

PSUTOORECEIVETHRSH

PS UtoO HO Receive
Level Threshold

BSC6900

PSUTURNINGOFFENABLE

PSU Turning Off Enable

BSC6900

PSW

Self-healing Switch for


OMU Process

BSC6900

PT

Cell Reselect Penalty


Time

BSC6900

PT

Port Type

BSC6900

PT

Port Type

BSC6900

PT

Subnet Protocol Type

BSC6900

PT

Port

BSC6900

PTCODE

Line code

BSC6900

PTRXT

Frame receive Structure

BSC6900

PTTXT

Frame send Structure

BSC6900

PTTYPE

Frame Structure

BSC6900

PTUID

HDLC Path Index In BTS

BSC6900

PTYPE

Port type

BSC6900

PTYPE

Power System Type

BSC6900

PubCert

Certificate File Name

BSC6900

PV

BTS Patch Version

BSC6900

PV

Patch Version

BSC6900

PVCUSERATETIMER

PVC Utilization Report


Period Timer

BSC6900

PWD

Password

BSC6900

PWD

User Password

BSC6900

PWD

Private Key Password

BSC6900

PwdMinLen

Minimum Password
Length

BSC6900

PWL

Power Level

BSC6900

PWRALMSSW1

First Alarm Switch

BSC6900

PWRALMSSW2

Second Alarm Switch

BSC6900

PWRBCDALLOWD

Power Forecast Allowed

BSC6900

PWRCTRLOPTIMIZEDEN

III Power Control


Optimized Enable

BSC6900

PWRCTRLSW

Power Control Switch

BSC6900

PWRDIV

Power Deviation

BSC6900

PWRDIVIND

Power Deviation
Indication

BSC6900

PWRLOCATION

Location Group Power


Switch

BSC6900

PWRMODE

Power Class

BSC6900

PWROFFPROTECTSTARTTI Power-off Protect Start


ME
Time

BSC6900

PWRPRIORALLOW

BSC6900

Power Priority Allowed

PWRSPNR

Power Finetune

BSC6900

PwrSwitchA

ANT_A ALD Power Switch BSC6900

PwrSwitchB

ANT_B ALD Power Switch BSC6900

PwrSwitchRET

RET ALD Power Switch

BSC6900

Q0MINDSCP

Min DSCP of queue 0

BSC6900

Q1MINDSCP

Min DSCP of queue 1

BSC6900

Q2MINDSCP

Min DSCP of queue 2

BSC6900

Q3MINDSCP

Min DSCP of queue 3

BSC6900

Q4MINDSCP

Min DSCP of queue 4

BSC6900

QCI

Qsearch C Initial

BSC6900

QCKMVHOEN

MS Fast Moving HO
Allowed

BSC6900

QCKSTATCNT

MS Fast-moving Watch
Cells

BSC6900

QCKTIMETH

MS Fast-moving Time
Threshold

BSC6900

QCKTRUECNT

MS Fast-moving Valid
Cells

BSC6900

QI

Qsearch I

BSC6900

QLENSD

Filter Length for TCH


Qual.

BSC6900

QLENSI

Filter Length for SDCCH


Qual.

BSC6900

QOSOPT

Support QoS Optimize

BSC6900

QP

Qsearch P

BSC6900

QSEARCHC

Qsearch C

BSC6900

QTRUCHANMANGSWITCH

QTRU Signal Merge Avoid


BSC6900
Switch

QTRUDNPWRLASTTIME

Qtru Down Power


Inadequate Last Time

BSC6900

QTRUDNPWRSTATTIME

Qtru Down Power


Inadequate Stat Time

BSC6900

QTRUPWRSHARE

Multi-Density TRX Power


BSC6900
Sharing

QUALOFFTIMES

Qualified Times for Off

BSC6900

QUALONTIMES

Qualified Times for On

BSC6900

QUALSTEP

MAX Down Adj. PC Value


BSC6900
by Qual.

QUERYCMAFTERINBSCHO

Query Classmark after


In-BSC HO Enabled

BSC6900

QUICKHOEN

Quick Handover Enable

BSC6900

R0AuxDev

SubRack0 Auxiliary
Equipment

BSC6900

R0BatAllow

SubRack0 Storage
Battery Config Permit

BSC6900

R0BatCap

SubRack0 Storage
Battery Capacity

BSC6900

R0BatCoeff

SubRack0 Storage
Battery Coefficient

BSC6900

R0BatType

SubRack0 Storage
Battery Type

BSC6900

R1AuxDev

SubRack1 Auxiliary
Equipment

BSC6900

R1BatAllow

SubRack1 Storage
Battery Config Permit

BSC6900

R1BatCap

SubRack1 Storage
Battery Capacity

BSC6900

R1BatCoeff

SubRack1 Storage
Battery Coefficient

BSC6900

R1BatType

SubRack1 Storage
Battery Type

BSC6900

R2AuxDev

SubRack2 Auxiliary
Equipment

BSC6900

R2BatAllow

SubRack2 Storage
Battery Config Permit

BSC6900

R2BatCap

SubRack2 Storage
Battery Capacity

BSC6900

R2BatCoeff

SubRack2 Storage
Battery Coefficient

BSC6900

R2BatType

SubRack2 Storage
Battery Type

BSC6900

RA

Route Area

BSC6900

RA

Route Area

BSC6900

RA

RAC

BSC6900

RA

Route Area

BSC6900

RA

Routing Area

BSC6900

RA1

Route Area

BSC6900

RACHACCLEV

CS RACH Min. Access


Level

BSC6900

RACHBUSYTHRED

RACH Busy Threshold

BSC6900

RACHLDAVERSLOT

Average RACH Load


Timeslot Number

BSC6900

RACJACCLEV

CS Min.Access Level

BSC6900

RACOLOR

Routing Area Color Code BSC6900

RANDACCESSRETRY

Allow MS to Access to
Another Cell

BSC6900

RANERRTHRED

Random Access Error


Threshold

RARESELECTHYST

Accessorial Hysteresis of
BSC6900
Cell Selection

RATE

Rate

RATECTRLSW

AMR Rate Control Switch BSC6900

RATSCCHENABLED

Is RATSCCH Function
Enabled

BSC6900

RAWMRSAMPLE

Raw MR Sample Ratio

BSC6900

BSC6900

BSC6900

RBPTYPE

Type of Rollback Point

BSC6900

RCDT

Result Recording Type

BSC6900

RCN

Chain No.

BSC6900

RCN1

First RXU Chain No.

BSC6900

RCN2

Second RXU Chain No.

BSC6900

RCVMD

Receive Mode

BSC6900

RDC

Rate down coefficient


[%]

BSC6900

REASSEN

Allow Reassign

BSC6900

REASSFREQBAND

Frequency Band of
Reassign

BSC6900

RECEIVEQUALTHRSHAMRF
ReceiveQualThrshAMRFR BSC6900
R
RECEIVEQUALTHRSHAMR
ReceiveQualThrshAMRHR BSC6900
HR

RECLEVHYST

RX_LEV Hysteresis

BSC6900

RECLEVTHRES

RX_LEV Threshold

BSC6900

RECLEVUOHOALLOW

RX_LEV for UO HO
Allowed

BSC6900

RecordDiscardedPagingInf Record Discarded Paging


BSC6900
oFlag
Msg
RECOVERTHD

Decrease rate alarm


recover threshold

BSC6900

RECQUALTH

RX_QUAL Threshold

BSC6900

RECQUALUOHOALLOW

RX_QUAL for UO HO
Allowed

BSC6900

RED

Backup

BSC6900

ReduceTransBwInt

Interval to Reduce
Transmission Bandwidth
when Congested

BSC6900

ReduceTransBwNum

Number of Transmission
Bandwidth to Reduce
when Congested

BSC6900

REF2MCLK2SRC

Port for LINE2

BSC6900

REF2MCLK2SRCBAK

Back-up port for LINE2

BSC6900

REF2MCLKSRC

Port for LINE1

BSC6900

REF2MCLKSRCBAK

Back-up port for LINE1

BSC6900

REF2MCLKSW1

Switch of panel 2M BITS1 BSC6900

REF2MCLKSW2

Switch of panel 2M BITS2 BSC6900

REFUSELOCALCLK

Use SGSN clock source

BSC6900

REGION

Region Information

BSC6900

REHOSTABSTIME

ReHost Absolute Time

BSC6900

REHOSTDELAYTIME

ReHostDelayTime

BSC6900

REHOSTTYPE

ReHost Type

BSC6900

REINITTBL

Reinitialize Neighbour
Cell Table

BSC6900

RELATEDCN

Associated Board CN

BSC6900

RELATEDFCUENABLED

Extend Connection
Configuration Enabled

BSC6900

RELATEDMODFUNC

Associated Board
Function

BSC6900

RELATEDSN

Associated Board SN

BSC6900

RELATEDSRN

Associated Board SRN

BSC6900

RELATEDTRACK

Cascading Tributary

BSC6900

REMARK

Remark

BSC6900

REMARK

Route use description

BSC6900

REMOTENSVLI

Remote NSVL ID

BSC6900

REP

Repeat

BSC6900

REPEATDLFASET

Repeated Downlink
FACCH

BSC6900

REPEATDLFATHRED

Repeated Downlink
FACCH Threshold

BSC6900

REPEATSASET

Repeated SACCH

BSC6900

RESALMID

Reserved Alarm ID.

BSC6900

ResCheckAllowed

ResCheckAllowed

BSC6900

RESELHYST

Cell Reselection
Hysteresis

BSC6900

RESELINTERVAL

Cell Reselect Interval

BSC6900

RESELWATCHPERIOD

Normal Cell Reselection


Watch Period

BSC6900

RESELWORSENLEVTHRSH

Normal Cell Reselection


Worsen Level Threshold

BSC6900

ReservedDynPdchPreTran Number of Reserved


Num
Dynamic Channel

BSC6900

ReservedIdleCh

Reserved TCH Number


for PA Turning On

BSC6900

ResetAlmDelaySwitch

BTS Reset Alarm Delay


Switch

BSC6900

ResetAlmDelayTime

BTS Reset Alarm Delay


Time

RESETINTERVAL

Reset Interval of Account


BSC6900
Lock Counter

RESETRETRY

Reset Retry

BSC6900

RESETTIME

BTS Reset Time

BSC6900

RESETTIMER

Reset Timer

BSC6900

RESID

Reason

BSC6900

RespReqSel

Response on Out-BSC HO
BSC6900
Req

REST

Resume Broken
Downloads Flag

BSC6900

RESTARTTMR

Sub-protocol negotiate
out time[S]

BSC6900

RESTARTTMR

Sub-protocol negotiate
out time[S]

BSC6900

RESTYPE

Alarm Restore Type

BSC6900

RESUMETIMER

Resume Timer

BSC6900

BSC6900

REVCHANNUM

Reserved Channel
Number

RFMAXPWRDEC

Max RC Power Reduction BSC6900

RFRESINDPRD

Radio Resource Report


Period

BSC6900

RFT

Execute Interval

BSC6900

RFUCFGBYSLOT

Configure RFU by Slot

BSC6900

BSC6900

RGPSINDICATION

GPS or RGPS

BSC6900

RIMSUP

RIM Support

BSC6900

RLCN

Channel No.

BSC6900

RLT

Radio Link Timeout

BSC6900

RMTTCATERTRANSMODE

Remote TC Subrack Ater


Transmission Mode

BSC6900

RNCID

RNC ID

BSC6900

RNCINDEX

Neighboring RNC Index

BSC6900

RNCINDEX

Neighboring RNC Index

BSC6900

RNCNAME

Neighboring RNC Name

BSC6900

RootCert

Root Certificate File


Name

BSC6900

ROUTENO

Route No.

BSC6900

ROUTEPORTNO

Route Port No.

BSC6900

RPTDLVQIALLOWED

Report Downlink VQI


Allowed

BSC6900

RPTPERIODI

Cell Reselection MR
Period in Packet Idle
Mode

BSC6900

RPTPERIODT

Cell Reselection MR
Period in Packet Transfer BSC6900
Mode

RPTTHD

Decrease rate alarm


report threshold

BSC6900

RPTVOICE

Report Speech Quality

BSC6900

RQSIGNLEN

Filter Length for SDCCH


REP_QUANT

BSC6900

RQTRAFFLEN

Filter Length for TCH


REP_QUANT

BSC6900

RSCGRPN

Rscgrp No.

BSC6900

RSCMNGMODE

Resource management
mode

BSC6900

RSCMNGMODE

Resource Management
Mode

BSC6900

RSCPENALTYTIMER

RscPenaltyTimer

BSC6900

RSCPOFF

RSCP Offset

BSC6900

RSCPTHRES

RSCP Threshold for Layer


BSC6900
of 3G Cell

RSDSRC

RSD alarm source

BSC6900

RSFSRC

RSF alarm source

BSC6900

RSLCTOFFER

GPRS Reselection Offset

BSC6900

RSLDL

BTS RSL Average Downbandwidth

BSC6900

RSLDSCP

RSL DSCP

BSC6900

RSLPRI

RSL Priority

BSC6900

RSLUL

BTS RSL Average Upbandwidth

BSC6900

RSLVLANID

RSL VlanId

BSC6900

RSLWS

RSL LAPD Window Size

BSC6900

RSNDES

Lock Reason

BSC6900

RSSThres

Relative Signal Strength


Threshold

BSC6900

RSTDESFILE

Reset file

BSC6900

RSTF

Result File Name

BSC6900

RSTFUN

Restart switch

BSC6900

RSTIME

Restart Timer

BSC6900

RSVCHMFORECNUM

Max Channel Num


Reserved for EC

BSC6900

RSVDPARA1

Reserved Parameter 1

BSC6900

RSVDPARA10

Reserved Parameter 10

BSC6900

RSVDPARA2

Reserved Parameter 2

BSC6900

RSVDPARA3

Reserved Parameter 3

BSC6900

RSVDPARA4

Reserved Parameter 4

BSC6900

RSVDPARA5

Reserved Parameter 5

BSC6900

RSVDPARA6

Reserved Parameter 6

BSC6900

RSVDPARA7

Reserved Parameter 7

BSC6900

RSVDPARA8

Reserved Parameter 8

BSC6900

RSVDPARA9

Reserved Parameter 9

BSC6900

RsvIdleChanNum

Reserve Idle Channel


Number

BSC6900

RT

Revertive type

BSC6900

RTCONTEXT

Routing Context

BSC6900

RTCPBWRATIO

RTCP Bandwidth Usage

BSC6900

RTCPSWITCH

Enable RTCP

BSC6900

RTDEST

Destination Network
Address

BSC6900

RTDESTMASK

Destination Address
Mask

BSC6900

RTIDX

Route Index

BSC6900

RTOALPHA

RTO alpha value

BSC6900

RTOBETA

RTO beta value

BSC6900

RTOINIT

RTO initial value

BSC6900

RTOMAX

RTO max value

BSC6900

RTOMIN

RTO min value

BSC6900

RTPSWITCH

Measure Link Delay


Switch

BSC6900

RTTIPDCHMULTIPLEXTHRE RTTI PDCH Multiplex


SH
Threshold

BSC6900

RTTYPE

Route Type

BSC6900

RUS

Rate up step [kbps]

BSC6900

RUSPRD

Rate up step adjust


period [PLPRD]

BSC6900

RVer

R-Version No.

BSC6900

RXBW

Backward Bandwidth

BSC6900

RxBw

Backward Bandwidth

BSC6900

RXLEVACCMIN

Minimum Receiving level


BSC6900
for Access

RXLEVOFF

Interfere HO Qual.
BSC6900
Thresh Offset for AMR FR

RXMIN

Minum Access RXLEV

BSC6900

RXQCKFALLHOEN

Rx_Level_Drop HO
Allowed

BSC6900

RXQUAL1

Interfere HO Qual.
BSC6900
Thresh 1 for Non-AMR FR

RXQUAL10

Interfere HO Qual.
Thresh 10 for Non-AMR
FR

BSC6900

RXQUAL11

Interfere HO Qual.
Thresh 11 for Non-AMR
FR

BSC6900

RXQUAL12

Interfere HO Qual.
Thresh 12 for Non-AMR
FR

BSC6900

RXQUAL2

Interfere HO Qual.
BSC6900
Thresh 2 for Non-AMR FR

RXQUAL3

Interfere HO Qual.
BSC6900
Thresh 3 for Non-AMR FR

RXQUAL4

Interfere HO Qual.
BSC6900
Thresh 4 for Non-AMR FR

RXQUAL5

Interfere HO Qual.
BSC6900
Thresh 5 for Non-AMR FR

RXQUAL6

Interfere HO Qual.
BSC6900
Thresh 6 for Non-AMR FR

RXQUAL7

Interfere HO Qual.
BSC6900
Thresh 7 for Non-AMR FR

RXQUAL8

Interfere HO Qual.
BSC6900
Thresh 8 for Non-AMR FR

RXQUAL9

Interfere HO Qual.
BSC6900
Thresh 9 for Non-AMR FR

RXUCHAINNO

RXU Chain No

BSC6900

RXUCHAINNO

RXU Chain No.

BSC6900

RXUCHAINNO

RXU Chain No.

BSC6900

RXUIDTYPE

RXU Index Type

BSC6900

RXUIDTYPE

RXU Index Type

BSC6900

RXUNAME

RXU Name

BSC6900

RXUNAME

RXU Name

BSC6900

RXUNAME

RXU Name

BSC6900

RXUPOS

RXU Chain Position

BSC6900

RXUPOS

RXU Chain Position

BSC6900

RXUPOS

RXU Board Position

BSC6900

RXUTYPE

RXU Board Type

BSC6900

S1SWITCH

S1 value setting switch

BSC6900

S1VALUE

S1 Value

BSC6900

SAADIS

Special Analog Alarm


Enabled

BSC6900

SAAF

Special Analog Alarm


Flag

BSC6900

SaGsmrMsc

Trunking MSC

BSC6900

SAICALLOWED

SAIC Allowed

BSC6900

SAICTHREDAPDTVALUE

Power Control Threshold


Adjust for SAIC

BSC6900

SAICTHREDAPDTVALUE

Power Control threshold


Adjust for SAIC

BSC6900

SALOG

Special Analog Alarm


Enabled

BSC6900

SAMECVGCELLID

Same Coverage Cell No

BSC6900

SAMECVGCELLIDTYPE

Same Coverage Cell


Index Type

BSC6900

SAMECVGCELLLOADSTATT Same Coverage Cell


M
Load Stat. Time

BSC6900

SAMECVGCELLLOADTHRD

Same Coverage Cell


Load Threshold

BSC6900

SAMECVGCELLNAME

Same Coverage Cell


Name

BSC6900

SAMULFRM

SACCH Multi-Frames

BSC6900

SAS

Special Alarm Switcher

BSC6900

SASE

Special Alarm Switch


Enabled

BSC6900

SASV

Special Alarm Switch


Valid Vol. Level

BSC6900

SAVEENABLED

Energy Saving Support

BSC6900

SBAF

Special Bool Alarm Flag

BSC6900

SBTSID

First BTS Index

BSC6900

SBTSNAME

First BTS Name

BSC6900

SCALEORDER

SCALE_ORDER

BSC6900

SCDSCP

DSCP of STREAM[QoS]

BSC6900

SCELLFILTER

Serving Cell Filter Length


BSC6900
MR Number

SCELLID

First Cell Index

BSC6900

SCELLNAME

First Cell Name

BSC6900

SCHEME

Coding Scheme

BSC6900

SCHNNO

Sub Channel No.

BSC6900

SCMD

Command String

BSC6900

SCOPETYPE

Scope Type

BSC6900

SCPIDX

Subrack Communication
BSC6900
Path Index

SCRAMBLE

Scrambling Code or Cell


Parameter Id

BSC6900

SCSN

Start Serial No.

BSC6900

SCTPLNKN

SCTP link No.

BSC6900

SD

Start Date

BSC6900

SD

Start Date

BSC6900

SD

Alarm Log Saved Time

BSC6900

SD

Start Date

BSC6900

SDALMTHD

SD Alarm Threshold

BSC6900

SDATE

Start Date

BSC6900

SDAY

Start date

BSC6900

SDCCHNUM

SDCCHChannelNumber

BSC6900

SDCCHWaitMREn

Waiting for MR on SDCCH


BSC6900
Switch

SDCCHWaitMRTimeLen

Duration for Waiting MR


on SDCCH

BSC6900

SDDROPSTATDLLEV

DL Level Threshold for


SDCCH Call Drop

BSC6900

SDDROPSTATDLQUAL

DL Quality Threshold for


SDCCH Call Drop

BSC6900

SDDROPSTATULLEV

UL Level Threshold for


SDCCH Call Drop

BSC6900

SDDROPSTATULQUAL

UL Quality Threshold for


SDCCH Call Drop

BSC6900

SDDYN

SDCCH Dynamic
Allocation Allowed

BSC6900

SDENABLE

SD Enable

BSC6900

SDFASTHOSWITCH

SD Quick HO

BSC6900

SDFLAG

Shut Down Enabled

BSC6900

SDHOMININTV

Min Interval for SDCCH


Hos

BSC6900

SDMRCUTNUM

SdMrCutNum

BSC6900

SDPUNTIME

Penalty Time on Fast


Moving HO

BSC6900

SDPUNVAL

Penalty on Fast Moving


HO

BSC6900

SDSCP

DSCP of Signaling

BSC6900

SDSFPRI

SDSF Priority

BSC6900

SDT

Shutdown Temperature

BSC6900

SDTMWDALMDIS

Sliding Time Window


Alarm Disappear

BSC6900

SDTMWDALMOC

Sliding Time Window


Alarm Occurrence

BSC6900

SDV

Shutdown Voltage

BSC6900

SEARCH3G

3G Search PRIO

BSC6900

SELFVERSION

Self Version

BSC6900

Send2QuterFlag

Support Sent 2QUATER

BSC6900

SendBssInvokeTrace

Spt BSS Invoke Trace


BSC6900
Rpt[end2end user trace]

SENDCMAFTERINBSCHO

Send Classmark ENQ


Result to MSC Enabled

SendConfusionToMSC

Sent Confusion Message


BSC6900
to MSC

BSC6900

SENDDOWNLINKMESSAG Send Downlink Message


E
after Hanging up

BSC6900

SENDFACCHNOTPRI

Send FACCH Notification


Priority

BSC6900

SENDFACCHPAGPRI

Send FACCH Paging


Priority

BSC6900

SENDSAMBE

BSC Auto Link Flag

BSC6900

SENDSI2TERFLAG

Send System Information


BSC6900
2ter

SENDSI5TERFLAG

Send System Information


BSC6900
5ter

SendUtranECSCFlag

Send 3G Class Flag

BSC6900

SEPARATEPOS

Separate Position

BSC6900

SEPERATEMODE

Separate Mode

BSC6900

SERCMDPORT

The Command Port of


FTP Server

BSC6900

SERDATAPORT

The Source Date Port of


FTP Server

BSC6900

SERIALNO

Device Serial No.

BSC6900

ServerIP

FTP Server IP Address

BSC6900

ServiceMode

Service mode

BSC6900

SERVICEMODE

Service Type

BSC6900

SERVICEMODE

Service Type

BSC6900

ServiceName

Service Name

BSC6900

SERVICETYPE

Service Type

BSC6900

SETDIESELENGINEENABLE Diesel Engine Configure


D
Enabled

BSC6900

SETENVPARAENABLED

ENV TEMP CFG Enabled

BSC6900

SETENVPARAENABLED

ENV TEMP CFG Enabled

BSC6900

SETHUMPARAENABLED

Environment Humidity
Configure Enabled

BSC6900

SFPPORTNO

SFP Port No

BSC6900

SGSNCAP

Configure Capacity<K
User Number>

BSC6900

SGSNNAME

SGSN Name

BSC6900

SGSNNRILEN

SGSN NRI Length

BSC6900

SGSNNULLNRI

SGSN NullNRI Value

BSC6900

SGSNPOOLALLOW

Allow SGSN Pool

BSC6900

SGSNR

Protocol Version
Supported by SGSN

BSC6900

SGSNSTATUS

SGSN Management
Status

BSC6900

SHAREINCPURATE

Share in CPU Rate

BSC6900

SHARESN

Load Sharing Slot No.

BSC6900

SHARINGALLOW

Sharing Allow

BSC6900

SHLDFLG

Shield Flag

BSC6900

SHUTDOWNTRXSTARTTIM Shutdown TRX Start


E
Time[T2]

BSC6900

SI2TerSwitch

SI 2ter Switch

BSC6900

SIGCHANHOEN

SDCCH HO Allowed

BSC6900

SIGLAST

Signal Strength Duration


BSC6900
Times

SIGLKSX

Signalling link set index

BSC6900

SIGLKSX

Signalling link set index

BSC6900

SIGLNKID

Signaling link ID

BSC6900

SIGLW

Signaling Load Weight

BSC6900

SIGLW

Signaling Load Weight

BSC6900

SIGNALSP

Signal Service PRI

BSC6900

SIGOBS

Signal Strength
Observation Times

BSC6900

SIGQUAFLTLEN

Filter Length for SDCCH


Qual

BSC6900

SIGSLC

Signalling link code

BSC6900

SIGSTRFLTLEN

Filter Length for SDCCH


Level

BSC6900

SilenceTicksOfResReq

Interval Between
Resource Request

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


1
MSISDN Number 1

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


10
MSISDN Number 10

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


11
MSISDN Number 11

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


12
MSISDN Number 12

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


13
MSISDN Number 13

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


14
MSISDN Number 14

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


15
MSISDN Number 15

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


16
MSISDN Number 16

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


17
MSISDN Number 17

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


18
MSISDN Number 18

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


19
MSISDN Number 19

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


2
MSISDN Number 2

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


20
MSISDN Number 20

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


3
MSISDN Number 3

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


4
MSISDN Number 4

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


5
MSISDN Number 5

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


6
MSISDN Number 6

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


7
MSISDN Number 7

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


8
MSISDN Number 8

BSC6900

SinglePassExcludeMsisdn Single Pass Exclude


9
MSISDN Number 9

BSC6900

SIPADDR

Source IP address

BSC6900

SIPADDR

Source IP address

BSC6900

SITES

Sites

BSC6900

SITESYNCZONE

Site Sync Zone

BSC6900

SLAVEIPADDR

Clock Server IP Address 2 BSC6900

SLAVELOCGRPNO

Sub-Location Group No.

BSC6900

SLPTYPE

Self Loop Type

BSC6900

SLSMASK

Signalling route mask

BSC6900

SLVSERVACTDELAY

Slave Service Active


Delay

BSC6900

SM

StartType

BSC6900

SMLCIDX

SMLC Index

BSC6900

SMLCMode

SMLC Mode

BSC6900

SMOKE_MASK

Enable Smoke Alarm


Reporting

BSC6900

SMONTH

Start month

BSC6900

SMWINDOW

Filter window

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No

BSC6900

SN

BM Slot No

BSC6900

SN

Slot No.

BSC6900

SN

Main Board Logic slot No. BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Port Slot No.

BSC6900

SN

Slot No.

BSC6900

SN

Slot No.

BSC6900

SNDMD

Send Mode

BSC6900

SndRcvMode

DRRU Sending Receiving


BSC6900
Mode

SndRcvMode1

DRFU Sending Receiving


BSC6900
Mode

SndRcvMode2

MRRU/GRRU Sending
Receiving Mode

BSC6900

SndRcvMode3

MRFU/GRFU Sending
Receiving Mode

BSC6900

SndRcvMode4

BTS3900E Sending
Receiving Mode

BSC6900

SP

Sync Period

BSC6900

SPC

OSP code[Whole
Number]

BSC6900

SPCBITS

OSP code bits

BSC6900

SPCDNF

OSP code[Divided
Number]

BSC6900

SPCIC

Start PCIC

BSC6900

SPDF

Signal point data format

BSC6900

SPECACC

Special Access Control


Class

BSC6900

SPECIALSWITCH

Special Alarm Switch

BSC6900

SPECIALSWITCHERLEVEL

Special Alarm Valid Level


BSC6900
Configuration

SpeechAlmPeriod

One-Way Mute Alarm


Reporting Period

SpeechVerInAssCmp

Speech VER Send Flag in


BSC6900
ASS CMP

SpeechVerinHoPerform

Speech VER Send Flag in


BSC6900
HO Perform

SpeechVerInHoReqAck

SpeechVerSend Flag in
HO REQ ACK

BSC6900

SpeechVerInHoRqd

HO_RQD Speech VER

BSC6900

SPEECHVERMODE1

Speech Version Mode 1

BSC6900

SPEECHVERMODE2

Speech Version Mode 2

BSC6900

SPEECHVERSION

Speech Version

BSC6900

SPEED

ETHPORT SPEED

BSC6900

BSC6900

SPEEDPUNISH

Penalty on MS Fast
Moving HO

BSC6900

SPEEDPUNISHT

Penalty Time on Fast


Moving HO

BSC6900

SPGCCCCHSUP

Support SPLIT_PG_CYCLE
BSC6900
on CCCH

SpprtCB

Support Cell Broadcast

BSC6900

SPTCOMMMEAS

Allow Common
Measurement at Iur-g

BSC6900

SPTINFOEXCHG

Allow Info Exchange at


Iur-g

BSC6900

SPTINTERRATINBSCPSHO

Support In Inter-RAT
Inter-cell PS Handover

BSC6900

SPTINTERRATOUTBSCPSH Support Out Inter-RAT


O
Inter-Cell PS Handover

BSC6900

SPTNACCResGuarantee

Support NACC Resource


Guarantee

SptPaging

Support Paging Message


BSC6900
from Trunking MSC

BSC6900

SptPbLapdCheck

Support Pb Lapd Check

BSC6900

SptPbResCheck

Support Pb Resource
Check

BSC6900

SptPbSglPassCheck

Support Pb Single Pass


Check

BSC6900

SptPCICCheck

Support PCIC Check

BSC6900

SptRanSharing

Support RAN Sharing

BSC6900

SPTREDUCELATENCY

Support Reduced
Latency Capability

BSC6900

SPTSHARING

RanSharing Support

BSC6900

SPTSTATEFWL

Support State Firewall

BSC6900

SPX

OSP index

BSC6900

SRANMODE

Is Support Normalized
Data Configuration

BSC6900

SRANMODE

Is Support SingleRAN
Mode

BSC6900

SRANMODE

Is Support SingleRAN
Mode

BSC6900

SRC2GNCELLID

Source Cell Index

BSC6900

SRC2GNCELLNAME

Source Cell Name

BSC6900

SRC3GNCELLID

Source Cell Index

BSC6900

SRC3GNCELLNAME

Source Cell Name

BSC6900

SRCCI

Source Cell CI

BSC6900

SRCF

Source File Name

BSC6900

SRCGRD

Clock source priority

BSC6900

SRCGRD

Clock source priority

BSC6900

SRCHOCTRLSWITCH

Current HO CTRL
Algorithm in Source Cell

BSC6900

SRCIP

Source IP Address

BSC6900

SRCLAC

Source Cell LAC

BSC6900

SRCMCC

Source Cell MCC

BSC6900

SRCMEPID

MEP ID

BSC6900

SRCMNC

Source Cell MNC

BSC6900

SRCPORTNO

Source port No.

BSC6900

SRCT

Clock source type

BSC6900

SRCTSMASK

Source timeslot mask

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

BM Subrack No

BSC6900

SRN

Subrack No

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Port Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN

Subrack No.

BSC6900

SRN1

Subrack 1 No

BSC6900

SRN2

Subrack 2 No

BSC6900

SRName

Subrack name

BSC6900

SRNO

Tributary No.

BSC6900

SRT

Subrack type

BSC6900

SRTORD

Sort Order

BSC6900

SRVLW

User Data Load Weight

BSC6900

SRVLW

User Data Load Weight

BSC6900

SRVPRIPOLICY

Service Priority Policy

BSC6900

SRVTYPE

Service Type

BSC6900

SSBQPUNISH

Penalty Level after BQ


HO

BSC6900

SSCPUAVEUSAGEALMTHD

CPU occupancy alarm


clearance threshold

BSC6900

SSCPUMAXUSAGEALMTH
D

CPU occupancy alarm


threshold

BSC6900

SSDSPAVEUSAGEALMTHD

DSP occupancy alarm


clearance threshold

BSC6900

SSDSPMAXUSAGEALMTH
D

DSP occupancy alarm


threshold

BSC6900

SSLENSD

Filter Length for TCH


Level

BSC6900

SSLENSI

Filter Length for SDCCH


Level

BSC6900

SSN

Subsystem No.

BSC6900

SSN

Subsystem No.

BSC6900

SSSN

Start Sync Serial No.

BSC6900

SSTAPUNISH

Penalty Level after TA HO BSC6900

ST

Start Time

BSC6900

ST

Start Time

BSC6900

ST

Start Time

BSC6900

ST

Start Time

BSC6900

ST

Start Time

BSC6900

ST

Start Time

BSC6900

ST

StartTime

BSC6900

STARTAID

Start Alarm ID

BSC6900

STARTCBSHORTMSGFLOW Prefer Variable Bitmap


CTRL
Code

BSC6900

STARTCHREQARRIVALCTR
CHAN REQ Arrival Control BSC6900
L

STARTCIC

Start CIC

BSC6900

STARTCIC

Start CIC

BSC6900

StartDayDSTPA

Prohibit Power Saving


Start Day

BSC6900

STARTHEATTEMP

Heater Startup
Temperature

BSC6900

StartMonthDSTPA

Prohibit Power Saving


Start Month

BSC6900

STARTPGARRIVALCTRL

Paging Arrival Control

BSC6900

STARTPSRESREQARRIVAL PS Resource REQ Arrival


CTRL
Control

BSC6900

STARTSUBTS

Start Sub Timeslot No.

BSC6900

STARTTIME

Fallback Start Time

BSC6900

StartTimeTACloseTrxPA

Time When the Function


Is Enabled

BSC6900

STARTTS

Start TS

BSC6900

STARTTS

Start TS

BSC6900

STARTTS

Start Timeslot No.

BSC6900

STC

Smart Temperature
Control

BSC6900

STC

Smart Temperature
Control

BSC6900

STCIC

Start CIC

BSC6900

STCN

Out Port Cabinet No.

BSC6900

STD

Start Date

BSC6900

STEP

Measurement Step

BSC6900

STFLG

Satellite flag

BSC6900

STIME

Start Time

BSC6900

STIRCALLOWED

EICC Allowed

BSC6900

STOPSI5SWITCH

Stop Send SI 5/5bis/5ter


after Encrypt

BSC6900

STOPTIME

Fallback Stop Time

BSC6900

STP

STP function switch

BSC6900

STPN

Out-BTS Port No.

BSC6900

STRTM

Start Time

BSC6900

STSN

Out Port Slot No.

BSC6900

STSRN

Out Port Subrack No.

BSC6900

STSUBTS

Out-BTS Sub Timeslot


No.

BSC6900

STT

Start Time

BSC6900

STTS

Out-BTS Timeslot No.

BSC6900

STTYPE

BTS Type

BSC6900

SUBBSCTID

ID of slave BSC in TC Pool BSC6900

SUBBSCTID

ID of slave BSC in TC Pool BSC6900

SUBCMD

Command Parameter

BSC6900

SUBFRAMELEN

Max subframe
length[byte]

BSC6900

SUBFRAMETHRES

Max Subframe Length

BSC6900

SUBID

Subtask ID

BSC6900

SUBNET

Subnet No

BSC6900

SUBRESPREEMPTFLG

Sublink Resources
Preemption Switch

BSC6900

SUBRESPREEMPTFLG

Sub Res Preempt Flag

BSC6900

SUBTS

Sub Timeslot No.

BSC6900

SubVer

Sub-Version No.of TMU

BSC6900

SupportApplyUsedCic

Support Apply Used A Cic BSC6900

SUPPORTBAKCLK2SRC

Use Back-up port for


LINE2

BSC6900

SUPPORTBAKCLKSRC

Use Back-up port for


LINE1

BSC6900

SUPPORTCELLBROADCAS Support Cell Broadcast


T
Name

BSC6900

SUPPORTDL5TS

Support High Multislot


Class

BSC6900

SUPPORTDTM

Support DTM

BSC6900

SUPPORTEDA

Support EDA

BSC6900

SUPPORTENDTM

Support Enhanced DTM

BSC6900

SupportIpSpanBtsLSwitch

Support FE/GE SPAN BTS


BSC6900
Local Switch

SupportTFOCodecOptimiz Support TFO Codec


e
Optimize

BSC6900

SupptCellList

SupptCellList

BSC6900

SVALUE

S Value

BSC6900

SVRIP

Server IP

BSC6900

SVRPORT

Server UDP Port

BSC6900

SW

Switch

BSC6900

SW

OMU Automatic
Switchover Switch

BSC6900

SW

Switch

BSC6900

SW

Switch

BSC6900

SW

Power Switch

BSC6900

SWEEK

Start week

BSC6900

Switch

Port switch

BSC6900

SWITCH

Bfd Protocol Switch

BSC6900

SWITCH

Grace Protection Period


Switch

BSC6900

SWITCH

Self-healing Switch

BSC6900

SWITCH

Alarm Parameter
Configuration Enabled

BSC6900

SWITCH3AH

3ah Switch

BSC6900

SWITCHBACKFLAG

Switch primary IP
address flag

BSC6900

SWITCHBACKHBNUM

Switch back HB number

BSC6900

SwitchParameter1

SwitchParameter1

BSC6900

SwitchParameter10

SwitchParameter10

BSC6900

SwitchParameter2

SwitchParameter2

BSC6900

SwitchParameter3

SwitchParameter3

BSC6900

SwitchParameter4

SwitchParameter4

BSC6900

SwitchParameter5

SwitchParameter5

BSC6900

SwitchParameter6

SwitchParameter6

BSC6900

SwitchParameter7

SwitchParameter7

BSC6900

SwitchParameter8

SwitchParameter8

BSC6900

SwitchParameter9

SwitchParameter9

BSC6900

SWITCHPORTNO

Switch Port

BSC6900

SWOP

Set Enable/Disable

BSC6900

SWSEQ

Start week sequence

BSC6900

SYMOFFSET

BTS Symbol Offset

BSC6900

SYNCCASE

Sync case

BSC6900

SYNCMETHOD

Site Synchronization
Method

BSC6900

SYNMODE

Clock Synchronization
Mode

BSC6900

SYNTIMEDAY

Days of Inter Sync Period BSC6900

SYNTIMEHOUR

Hours of Inter Sync


Period

BSC6900

SYNTIMEMIN

Minutes of Inter Sync


Period

BSC6900

SYSCONTACT

Contact mode of the


manufacturer

BSC6900

SYSDESC

System description

BSC6900

SYSFLOWLEV

System Flux Threshold


for Load HO

BSC6900

SYSLOCATION

System Location

BSC6900

SysMsg10Allowed

Send System Message


10 Allow

BSC6900

SYSOBJECTID

NE Name

BSC6900

SYSSERVICES

System services

BSC6900

T1

Time1

BSC6900

T1

T1

BSC6900

T10TMR

Signalling route set test


timer

BSC6900

T12TMR

Uninhibit ACK timer

BSC6900

T13TMR

Force uninhibit timer

BSC6900

T14TMR

Inhibition ACK timer

BSC6900

T17TMR

Link realignment timer

BSC6900

T1TMR

Time-control changeover
BSC6900
timer

T2

Time2

BSC6900

T2

T2

BSC6900

T200

T200

BSC6900

T200FACCHF

T200 FACCH/F

BSC6900

T200FACCHH

T200 FACCH/H

BSC6900

T200SACCH3

T200 SACCH TCH SAPI3

BSC6900

T200SACCHS

T200 SACCH SDCCH

BSC6900

T200SACCT0

T200 SACCH TCH SAPI0

BSC6900

T200SDCCH

T200 SDCCH

BSC6900

T200SDCCH3

T200 SDCCH SAPI3

BSC6900

T203

T203

BSC6900

T22TMR

Local inhibit test timer

BSC6900

T23TMR

Remote inhibit test timer BSC6900

T2TMR

Changeover ACK timer

BSC6900

T3

Time3

BSC6900

T3

T3

BSC6900

T3105

T3105

BSC6900

T3115

T3115

BSC6900

T3168

T3168

BSC6900

T3192

T3192

BSC6900

T3212

T3212

BSC6900

T391

Parameter of DTE [T391] BSC6900

T3TMR

Time-control changeback
BSC6900
timer

T4

T4

BSC6900

T4TMR

Changeover ACK first


attempt timer

BSC6900

T5

T5

BSC6900

T5TMR

Changeover ACK second


BSC6900
attempt timer

T6

T6

BSC6900

T8

T8

BSC6900

T8TMR

Transmission prohibited
inhibition timer

BSC6900

TAFLTLEN

Filter Length for TA

BSC6900

TAFORUOHOALLOW

TA for UO HO Allowed

BSC6900

TAHOEN

TA HO Allowed

BSC6900

TAHYST

TA Hysteresis

BSC6900

TALASTTIME

TA HO Valid Time

BSC6900

TALIMIT

TA Threshold

BSC6900

TALKERINFINT

Talker Info Interval

BSC6900

TASIGSTRFLTLEN

TA Filter Length for


SDCCH Level

BSC6900

TASKIDX

AISS Task Index

BSC6900

TASTATTIME

TA HO Watch Time

BSC6900

TATHRES

TA Threshold

BSC6900

TAVGT

T_AVG_T

BSC6900

TAVGW

T_AVG_W

BSC6900

TB

Output Segment No

BSC6900

TB

Output Segment No.

BSC6900

TBS

Try Switching Duration


Time

BSC6900

TBS

Ring I Try Rotating


Duration Time

BSC6900

TC

Test code

BSC6900

TC

Tc

BSC6900

TCC

Temperature
Compensation
Coefficient

BSC6900

TCCRCAllowed

TC CRC Allowed

BSC6900

TCHAJFLAG

TCH Rate Adjust Allow

BSC6900

TCHBUSYTHRES

TCH Traffic Busy


Threshold

BSC6900

TCHDROPSTATDLFER

DL FER Threshold for TCH


BSC6900
Call Drop

TCHDROPSTATDLLEV

DL Level Threshold for


TCH Call Drop

BSC6900

TCHDROPSTATDLQUAL

DL Quality Threshold for


TCH Call Drop

BSC6900

TCHDROPSTATULFER

UL FER Threshold for TCH


BSC6900
Call Drop

TCHDROPSTATULLEV

UL Level Threshold for


TCH Call Drop

BSC6900

TCHDROPSTATULQUAL

UL Quality Threshold for


TCH Call Drop

BSC6900

TCHHOMININTV

Min Interval for TCH Hos

BSC6900

TCHMRCUTNUM

TchMrCutNum

BSC6900

TCHRATEMODIFY

TCH Rate Modify

BSC6900

TCHTIMEHOPERIOD

TCH Time Handover


Period

BSC6900

TCHTIMEHOSWITCH

TCH Time Handover


Switch

BSC6900

TCHTRIBUSYUNDERLAYTH Tch Traffic Busy Underlay


BSC6900
R
Threshold

TCHTRICBUSYOVERLAYTH Tch Traffic Busy Overlay


R
Threshold

BSC6900

TCLEN

Test code length

BSC6900

TCMODE

TC mode

BSC6900

TCMUTEDETECTFLAG

Mute Detect Class1


Switch

BSC6900

TCN

Tail Cabinet No.

BSC6900

TCPN

TC Port No

BSC6900

TCPOOLID

TC Pool ID

BSC6900

TCSN

TC Slot No

BSC6900

TCSRN

TC Subrack No

BSC6900

TCTYPE

The type of TC resource

BSC6900

TDDBA1TAG

TDD BA1 Input Tag

BSC6900

TDDBA2TAG

TDDBA2 Input Tag

BSC6900

TDDCELLOFF

TDD Reporting Offset

BSC6900

TDDCELLRESELDIV

TDD Cell Reselect


Diversity

TDDCELLTHRED

TDD Reporting Threshold BSC6900

TDDDIVERSITY

Diversity

BSC6900

TDDDLUARFAN

DL UARFAN

BSC6900

TDDMIOPTIMIZEDALLOWE TDD MI System


D
Information Optimized

BSC6900

BSC6900

TDDMIPROHIBIT

TDD MI System INFO


Broadcasting Prohibit

BSC6900

TDDRSCPQUALTHRSH

PS TDD RSCP Quality


Threshold

BSC6900

TDDSCRAMBLE

Cell Parameter ID

BSC6900

TDDSCRAMBLE

Cell Parameter ID

BSC6900

TDDSIOPTIMIZEDALLOWE TDD System Information


BSC6900
D
Optimized Allowed

TDDSYNCCASE

Sync Case

BSC6900

TDMCONGCLRTH

Congestion clear remain


BSC6900
ratio

TDMCONGTH

Congestion remain ratio

BSC6900

TDMN1

Subrack 1 TDM Port No

BSC6900

TDMN2

Subrack 2 TDM Port No

BSC6900

TEI

TEI

BSC6900

TEMP_MASK

Enable Temperature
Alarm Reporting

BSC6900

TEMP_THD_HIGH

Upper Limit of
Temperature Alarm

BSC6900

TEMP_THD_LOW

Lower Limit of
Temperature Alarm

BSC6900

TEMPALARMTHRESHOLDH Upper ENV TEMP Alarm

BSC6900

TEMPALARMTHRESHOLDH Upper ENV TEMP Alarm

BSC6900

TEMPALARMTHRESHOLDL Lower ENV TEMP Alarm

BSC6900

TEMPALARMTHRESHOLDL Lower ENV TEMP Alarm

BSC6900

TEMPCOMPENSATECOEF

Coefficient of Temp
Compensation

TEMPLATEDESC

Cell Template Description BSC6900

TEMPLATEID

Cell Template Index

BSC6900

TEMPLATEID

Cell Template Index

BSC6900

BSC6900

TEMPLATENAME

Cell Template Name

BSC6900

TEMPOFHIGHTEMPLOADP Temp Of High Temp. Load


BSC6900
WROFF
Power Off

TEMPOFLOWTEMPLOADP
WROFF

Low Temperature Start


Load Power Off Temp.

BSC6900

TEMPOFLOWTEMPLOADP
WROFF

Low Temperature Start


Load Poweroff Temp.

BSC6900

TER2INDICATOR

TER Indicator of System


Information 3

BSC6900

TESTTIMER

Test Timer

BSC6900

TEXT

Content of Message

BSC6900

TFOOptSwitch

TFO Option Switch

BSC6900

TFREQ

Test Frequency

BSC6900

TFRMSTARTTIME

Frame Start Time

BSC6900

TG

Target OMU

BSC6900

TGWID

TGW ID

BSC6900

TGWIPOAMIP

TGW IP_TRANS IP
address

BSC6900

TGWIPOAMMASK

TGW IP_TRANS IP Mask

BSC6900

TGWPEERSN

TGW TRANS Slot No.

BSC6900

TGWPEERSRN

TGW Trans Subrack No.

BSC6900

TH

Th

BSC6900

THDOFF

Volt Threshold for Off

BSC6900

THDON

Volt Threshold for On

BSC6900

THP1ARP1PRIWEIGHT

THP1-ARP1 Priority
Weight

BSC6900

THP1ARP2PRIWEIGHT

THP1-ARP2 Priority
Weight

BSC6900

THP1ARP3PRIWEIGHT

THP1-ARP3 Priority
Weight

BSC6900

THP2ARP1PRIWEIGHT

THP2-ARP1 Priority
Weight

BSC6900

THP2ARP2PRIWEIGHT

THP2-ARP2 Priority
Weight

BSC6900

THP2ARP3PRIWEIGHT

THP2-ARP3 Priority
Weight

BSC6900

THP3ARP1PRIWEIGHT

THP3-ARP1 Priority
Weight

BSC6900

THP3ARP2PRIWEIGHT

THP3-ARP2 Priority
Weight

BSC6900

THP3ARP3PRIWEIGHT

THP3-ARP3 Priority
Weight

BSC6900

THTYPE

Threshold type

BSC6900

TI_WAIT_SGSN_PRIVATE_M Receive SGSN Config.


ESSAGE
Msg. Timer

BSC6900

TIGHTBCCHASSMAINBCC
HLEV

BSC6900

Level Thresh for Assign


BCCH Under TBCCH

TIGHTBCCHASSMAINBCC
HQUAL

Quality Thresh for Assign


BSC6900
BCCH Under TBCCH

TIGHTBCCHHOLASTTIME

TIGHT BCCH HO Valid


Time

BSC6900

TIGHTBCCHHOLOADTHRE Load Threshold for TIGHT


BSC6900
S
BCCH HO

TIGHTBCCHHOSTATTIME

TIGHT BCCH HO Watch


Time

BSC6900

TIGHTBCCHRXQUALTHRES

RX_QUAL Threshold for


TIGHT BCCH HO

BSC6900

TIGHTBCCHSWITCH

TIGHT BCCH Switch

BSC6900

TIGHTSDCCHRXLEVTHRE
D

IBCA Tight Trx SDCCH


Rxlev Threshold

BSC6900

TIIMSIPAGING

IMSI Paging Timer

BSC6900

TIME

Duration

BSC6900

TIME

Time

BSC6900

TIME

Time Limit

BSC6900

TIMEAMRFHPUNISH

Penalty Time after AMR


TCHF-H HO Fail

BSC6900

TIMEBQPUNISH

Penalty Time after BQ HO BSC6900

TIMEOTOUFAILPUN

Penalty Time after OtoU


HO Fail

BSC6900

TIMEOUT

Maximum Delay Time

BSC6900

TIMEOUT

Reply Time-Out[ms]

BSC6900

TIMEOUT

Reply Time-Out[ms]

BSC6900

Timeout

Time Out

BSC6900

TIMEOUT

Time Out

BSC6900

TIMEPUNISH

Quick Handover Punish


Time

BSC6900

TIMES

Number of ping packets

BSC6900

TIMESLOTVOLADJALLOW

Voltage Adjust Based


Timeslots Allowed

BSC6900

TIMETAPUNISH

Penalty Time after TA HO BSC6900

TIMEUTOOFAILPUN

Penalty Time after UtoO


HO Fail

BSC6900

TIQUEUINGTIMER

T11

BSC6900

TIWAITMSCMSG

Receive MSC
Configuration Message
Timer

BSC6900

TL

Time Limit

BSC6900

TLLI

TLLI

BSC6900

TLT

Tout Limit

BSC6900

TLTHD

Temperature Alarm
Lower Threshold

BSC6900

TLTHD

Temperature Alarm
Lower Threshold

BSC6900

TM

Execute Time

BSC6900

TM1

Execute Time 1

BSC6900

TM2

Execute Time 2

BSC6900

TM3

Execute Time 3

BSC6900

TM4

Execute Time 4

BSC6900

TM5

Execute Time 5

BSC6900

TMI

TRMMAP ID

BSC6900

TMIGLD

TRMMAP index

BSC6900

TMLEN

Time Length

BSC6900

TMODE

Test Mode

BSC6900

TMRBADQUALDISCSTAT

Timer for Bad Quality


DISC Statistic

BSC6900

TMRISTHRD

Upper time threshold of


raised fault

BSC6900

TMSI

TMSI

BSC6900

TMSTLTHRD

Lower time threshold of


raised fault

BSC6900

TMT1TMR

Signalling link test ACK


timer

BSC6900

TMT2TMR

Signalling link repeat


test timer

BSC6900

TNAME

Data Table

BSC6900

TNMODE

Transmission Mode

BSC6900

TNMODE

Transmission Mode

BSC6900

TO

Cell Reselect Temporary


Offset

BSC6900

TO

AdjustMethod

BSC6900

TOPBOARDCN

TOP Board Cabinet No.

BSC6900

TOPBOARDSLOTNO

TOP Board Slot No.

BSC6900

TOPBOARDSRN

TOP Board Subrack No.

BSC6900

TP

Log Type

BSC6900

TPN

Tail Port No.

BSC6900

TQHO

Into-BSC HO REQ Queue


Timer

BSC6900

TRACECTHD

Debug tracking control


threshold

BSC6900

TRACECTHD

Debug tracking control


threshold

BSC6900

TRACERTHD

Debug tracking restore


threshold

BSC6900

TRACERTHD

Debug tracking restore


threshold

BSC6900

TRACESW

Debug Flow control


switch

BSC6900

TrafficClassDlCoefficient

DL Priority Decision
Threshold

BSC6900

TrafficClassUlCoefficient

UL Priority Decision
Threshold

BSC6900

TRAMODE

Traffic mode

BSC6900

TransMode

Transmission Mode

BSC6900

TRANSSN

Load Transmitting Slot


No.

BSC6900

TRANST

Transport Type

BSC6900

TRANST

Transport Type

BSC6900

TRANST

Transport Type

BSC6900

TRANSTYPE

BTS Transmission Type

BSC6900

TRANSTYPE

Carrier Type

BSC6900

TRANSTYPE0

E1 Port 0 Set Optical


Transmission Mode

BSC6900

TRANSTYPE1

E1 Port 1 Set Optical


Transmission Mode

BSC6900

TRANSTYPE2

E1 Port 2 Set Optical


Transmission Mode

BSC6900

TRANSTYPE3

E1 Port 3 Set Optical


Transmission Mode

BSC6900

TRCRNGLMT

Trace Mode

BSC6900

TRESEL

Cell Reselection
Forbidden Time

BSC6900

TRIGTHRES

Load HO Threshold

BSC6900

TRKLNKPN

Trunk Link No.

BSC6900

TRKLNKSN

Trunk Link Slot No.

BSC6900

TRKN

Trunk No.

BSC6900

TRMI

User TRMMAP index

BSC6900

TRMLOADTHINDEX

TRM load threshold index BSC6900

TRMLOADTHINDEX

TRM load threshold index BSC6900

TRMLOADTHINDEX

TRM load threshold index BSC6900

TRMLOADTHINDEX

TRM load threshold index BSC6900

TRMLOADTHINDEX

TRM load threshold index BSC6900

TRMLOADTHINDEX

TRM load threshold index BSC6900

TRMLOADTHINDEX

TRM load threshold index BSC6900

TRMMAPSW

Transport Resource
Mapping switch

BSC6900

TRUNKN

Trunk No.

BSC6900

TRUNKN

Trunk group No.

BSC6900

TRUNKN

The Trunk group No.

BSC6900

TRXAIDSWITCH

TRX Aiding Function


Control

BSC6900

TRXDURATS

Duration Second

BSC6900

TRXHOPINDEX

Channel Hop Index

BSC6900

TRXID

TRX ID

BSC6900

TRXID

TRX ID

BSC6900

TRXID1

No.1 TRX ID

BSC6900

TRXID10

No.10 TRX ID

BSC6900

TRXID11

No.11 TRX ID

BSC6900

TRXID12

No.12 TRX ID

BSC6900

TRXID13

No.13 TRX ID

BSC6900

TRXID14

No.14 TRX ID

BSC6900

TRXID15

No.15 TRX ID

BSC6900

TRXID16

No.16 TRX ID

BSC6900

TRXID17

No.17 TRX ID

BSC6900

TRXID18

No.18 TRX ID

BSC6900

TRXID19

No.19 TRX ID

BSC6900

TRXID2

No.2 TRX ID

BSC6900

TRXID20

No.20 TRX ID

BSC6900

TRXID21

No.21 TRX ID

BSC6900

TRXID22

No.22 TRX ID

BSC6900

TRXID23

No.23 TRX ID

BSC6900

TRXID24

No.24 TRX ID

BSC6900

TRXID3

No.3 TRX ID

BSC6900

TRXID4

No.4 TRX ID

BSC6900

TRXID5

No.5 TRX ID

BSC6900

TRXID6

No.6 TRX ID

BSC6900

TRXID7

No.7 TRX ID

BSC6900

TRXID8

No.8 TRX ID

BSC6900

TRXID9

No.9 TRX ID

BSC6900

TRXIDLST

TRX Index List

BSC6900

TRXIDLST

TRXID LST

BSC6900

TRXMAIO

Channel MAIO

BSC6900

TRXNO

TRX No.

BSC6900

TrxNum

TRX Number

BSC6900

TRXPN

Sub-Location Group TRX


Board Pass No.

BSC6900

TRXPN

TRX Board Pass No.

BSC6900

TRXPRIALLOW

Allocation TRX Priority


Allowed

BSC6900

TRXTP

TRX Board Type

BSC6900

TS

Time Slot

BSC6900

TS

Time Slot

BSC6900

TS

Bearing Timeslot

BSC6900

TS

time slot No.

BSC6900

TS

Time Slot NO.

BSC6900

TSBITMAP

Bearing Time Slot

BSC6900

TSBITMAP

Bearing time slot

BSC6900

TSBITMAP

Bearing time slot

BSC6900

TSC

TSC

BSC6900

TSCOUNT

Idle TS Count

BSC6900

TSCPLANEN

TSC Plan Enable

BSC6900

TSCROSSX

Time slot cross index

BSC6900

TSDURAT

Duration * 10 minutes

BSC6900

TSIDX

Timeslot Index

BSC6900

TSKN

Task Name

BSC6900

TSMASK

Timeslot Mask

BSC6900

TSMASK

TS Mask

BSC6900

TSN

Tail Slot No.

BSC6900

TSNO

Timeslot No.

BSC6900

TSPRIORITY

Timeslot Priority

BSC6900

TSPWRRESERVE

Timeslot Power Reserve

BSC6900

TSRAPIDADJPERIOD

Fast Flux Measurement


TBF Timer

BSC6900

TSRAPIDADJSWITCH

Fast Flux Detection


Switch

BSC6900

TSRATE

Time Slot Rate

BSC6900

TSRN

Tail Subrack No.

BSC6900

TSTMODE

Test Mode

BSC6900

TSTTIMESLOT

Test Timeslot

BSC6900

TSTTYPE

Test Type

BSC6900

TSTTYPE

Test Type

BSC6900

TsTurningOffEnable

Allow Turning Off Time


Slot

BSC6900

TT

Topo Type

BSC6900

TTL

Time to Live

BSC6900

TTL

PKT TTL

BSC6900

TURNOFFCELLCHANNUM

Dyn. Turning Off Cell


Busy Channel Num.

BSC6900

TURNOFFCELLSTPTIME

Dyn. Turning Off Cell


Stop Time

BSC6900

TURNOFFCELLSTRTIME

Dyn. Turning Off Cell


Start Time

BSC6900

TURNOFFENABLE

Enable Turning Off Cell

BSC6900

TURNONCELLLOADTHRD

Dyn. Turning On Cell


Load Threshold

BSC6900

TUTHD

Temperature Alarm
Upper Threshold

BSC6900

TUTHD

Temperature Alarm
Upper Threshold

BSC6900

TWFCMCHIDLE

Observation Cell Channel


BSC6900
Reservation Timer

TWFCMTRXIDLE

Observation Cell TRX


Reservation Timer

BSC6900

TWFCSCHIDLE

Serving Cell TCHF


Reservation Timer

BSC6900

TWFRRMRSP

Information Collection
Response Timer

BSC6900

TWFSEEKMS

MS Search Timer

BSC6900

TWFSYNCACK

BTS Reserved Resource


Activation Timer

BSC6900

TWFSYNCRPT

BTS SYNC_REPORT Timer BSC6900

TX

TX-integer

BSC6900

TXAOPER1

Assigned Power of Pass A


BSC6900
Operators 1

TXAOPER2

Assigned Power of Pass A


BSC6900
Operators 2

TXAOPER3

Assigned Power of Pass A


BSC6900
Operators 3

TXAOPER4

Assigned Power of Pass A


BSC6900
Operators 4

TXBOPER1

Assigned Power of Pass B


BSC6900
Operators 1

TXBOPER2

Assigned Power of Pass B


BSC6900
Operators 2

TXBOPER3

Assigned Power of Pass B


BSC6900
Operators 3

TXBOPER4

Assigned Power of Pass B


BSC6900
Operators 4

TXBW

Forward Bandwidth

BSC6900

TxBw

Forward Bandwidth

BSC6900

TXINT

TX_INT

BSC6900

TXINT

Interval of send[ms]

BSC6900

TYPE

Freq. Band

BSC6900

TYPE

Subrack Type

BSC6900

TYPE

Freq. Band

BSC6900

TYPE

PCU Type

BSC6900

TYPE

Finish Type

BSC6900

TYPE

Cabinet Type

BSC6900

TYPE

Cell Type

BSC6900

U0GEN

Up0 Power Attenuation


Factor

BSC6900

U0TOW

Up0 Tower-Top Amplifier


Flag

BSC6900

U0TRX

Up0 Link No.

BSC6900

U0TRXBPN

Up0 TRX Board Pass No.

BSC6900

U0TRXSN

Up0 TRX Slot No.

BSC6900

U0TRXSRN

Up0 TRX Subrack No.

BSC6900

U1GEN

Up1 Power Attenuation


Factor

BSC6900

U1TOW

Up1 Tower-Top Amplifier


Flag

BSC6900

U1TRX

Up1 Link No.

BSC6900

U1TRXBPN

Up1 TRX Board Pass No.

BSC6900

U1TRXSN

Up1 TRX Slot No.

BSC6900

U1TRXSRN

Up1 TRX Subrack No.

BSC6900

ucCSPrefCallReestPrio

CS Preferred Call
Reestablish Priority

BSC6900

ucCSPrefCSEmergCallPrio

CS Preferred CS
Emergency Call Priority

BSC6900

ucCSPrefCSOrgCallPrio

CS Preferred CS MOC
Priority

BSC6900

ucCSPrefCSTermCallPrio

CS Preferred CS MTC
Priority

BSC6900

ucCSPrefInBscHoPrio

CS Preferred Into-BSC HO
BSC6900
Priority

ucCSPrefIntraBscHoPrio

CS Preferred Intra-BSC
HO Priority

BSC6900

ucCSPrefOtherPrio

CS Preferred Other
Service Priority

BSC6900

ucCSPrefPSPrio

CS Preferred PS Priority

BSC6900

ucCSPrefSupplePrio

CS Preferred Supplement
BSC6900
Priority

ucCSPrefVBSPrio

CS Preferred VBS Priority BSC6900

ucCSPrefVGCSPrio

CS Preferred VGCS
Priority

BSC6900

ucCtrlOfCicIE

Controlling of CIC IE In
BSS Map Messages

BSC6900

UCISRAIFAULT

RAI Alarm Switch

BSC6900

ucPSPrefCallReestPrio

PS Preferred Call
Reestablish Service
Priority

BSC6900

PS Preferred CS
ucPSPrefCSEmergCallPrio Emergency Call Service
Priority

BSC6900

ucPSPrefCSOrgCallPrio

PS Preferred CS Original
Call Service Priority

BSC6900

ucPSPrefCSTermCallPrio

PS Preferred CS
Terminated Call Service
Priority

BSC6900

ucPSPrefInBscHoPrio

PS Preferred In Handover
BSC6900
Service Priority

ucPSPrefIntraBscHoPrio

PS Preferred Intra
BSC6900
Handover Service Priority

ucPSPrefOtherPrio

PS Preferred Other
Service Priority

BSC6900

ucPSPrefPSPrio

PS Preferred PS Service
Priority

BSC6900

ucPSPrefSupplePrio

PS Preferred Supplement
BSC6900
Service Priority

ucPSPrefVBSPrio

PS Preferred VBS Service


BSC6900
Priority

ucPSPrefVGCSPrio

PS Preferred VGCS
Service Priority

BSC6900

ucSpeechVerOptiInHo

Speech Ver Change


Optimize in Handover

BSC6900

UDPMUXMODRECV

Receive UDP MUX Mode

BSC6900

UDPMUXMODSEND

Sender UDP MUX Mode

BSC6900

UDPPN

Local UDP Port No.

BSC6900

UDPPN

Remote UDP Port No.

BSC6900

UG

Operator Level

BSC6900

UHUMTHD

Upper Humidity
Threshold

BSC6900

UIC

UIC

BSC6900

UINTTIME

Unit time[ms]

BSC6900

UL

Upper Limit

BSC6900

UL

Upper Limit

BSC6900

ULADJPRD

PwrCtrlULAdjPeriod

BSC6900

ULAFSREXQUALHIGHTHR
ULAFSRexQualHighThred BSC6900
ED

ULAFSREXQUALLOWTHRE
ULAFSRexQualLowThred
D

BSC6900

ULAHSREXQUALHIGHTHR
ULAHSRexQualHighThred BSC6900
ED

ULAHSREXQUALLOWTHRE
ULAHSRexQualLowThred BSC6900
D

ULBQLASTTIME

UL BQ HO Last Time

BSC6900

ULBQSTATTIME

UL BQ HO Static Time

BSC6900

ULCOEFFICIENTTSRAPIDA Fast UL Priority Decision


DJ
Threshold

BSC6900

ULDATAFWDTMR

Timer for UL Data


Forward

BSC6900

ulDlAckFreq

RRBP Frequency for


GPRS Downlink TBF

BSC6900

ULEDGETHRES

Edge HO UL RX_LEV
Threshold

BSC6900

ulEgprsDlAckFreq

RRBP Frequency for


EGPRS Downlink TBF

BSC6900

ulEgprsUlAckFreq

ACK Frequency for


EGPRS Uplink TBF

BSC6900

ULFILTADJFACTOR

III UL Filter Adjust Factor

BSC6900

ULFSREXQUALHIGHTHRE
D

ULFSRexQualHighThred

BSC6900

ULFSREXQUALLOWTHRED ULFSRexQualLowThred

BSC6900

ULHSREXQUALHIGHTHRE
ULHSRexQualHighThred
D

BSC6900

ULHSREXQUALLOWTHRE
D

ULHSRexQualLowThred

BSC6900

ULHYSTF1

AMR UL Coding Rate


adj.hyst1[F]

BSC6900

ULHYSTF2

AMR UL Coding Rate


adj.hyst2[F]

BSC6900

ULHYSTF3

AMR UL Coding Rate


adj.hyst3[F]

BSC6900

ULHYSTH1

AMR UL Coding Rate


adj.hyst1[H]

BSC6900

ULHYSTH2

AMR UL Coding Rate


adj.hyst2[H]

BSC6900

ULHYSTH3

AMR UL Coding Rate


adj.hyst3[H]

BSC6900

ULHYSTWB1

AMR UL Coding Rate


adj.hyst1[WB]

BSC6900

ULHYSTWB2

AMR UL Coding Rate


adj.hyst2[WB]

BSC6900

UlLdrThrd2GCell

2G Cell UL Basic Congest


BSC6900
Thred

ULLEVFILTLEN

Filter Length for UL


RX_LEV

BSC6900

ULMAXDOWNSTEP

ULMAXDownStep

BSC6900

ULMAXUPSTEP

ULMAXUpStep

BSC6900

UlOlcThrd2GCell

2G Cell UL Overload
Congest Thred

BSC6900

ULPREDLEND

UL MR. Number Predicted BSC6900

ULQHIGHTHRED

UL Qual. Upper
Threshold

ULQLOWTHRED

UL Qual. Lower Threshold BSC6900

ULQUAFILTLEN

Filter Length for UL Qual. BSC6900

ULQUALBADTRIG

UL Qual. Bad Trig


Threshold

BSC6900

ULQUALBADUPLEV

UL Qual. Bad UpLEVDiff

BSC6900

BSC6900

ULQUALIMIT

UL Qual. Threshold

BSC6900

ULQUALIMITAMRFR

UL Qual. Limit for AMR


FR

BSC6900

ULQUALIMITAMRHR

UL Qual. Limit for AMR


HR

BSC6900

ULREXLEVADJFCTR

ULRexLevAdjustFactor

BSC6900

ULREXLEVEXPFLTLEN

ULRexLevExponentFilterL
BSC6900
en

ULREXLEVHIGHTHRED

ULRexLevHighThred

BSC6900

ULREXLEVLOWTHRED

ULRexLevLowThred

BSC6900

ULREXLEVSLDWINDOW

ULRexLevSlideWindow

BSC6900

ULREXQUALADJFCTR

ULRexQualAdjustFactor

BSC6900

ULREXQUALEXPFLTLEN

ULRexQualExponentFilter
BSC6900
Len

ULREXQUALSLDWINDOW ULRexQualSlideWindow

BSC6900

ULRXLEVPROTECTFACTOR

III UL RexLev Protect


Factor

BSC6900

ULRXQUALPROTECTFACT
OR

III UL RexQual Protect


Factor

BSC6900

ULSSHIGHTHRED

UL RX_LEV Upper
Threshold

BSC6900

ULSSLOWTHRED

UL RX_LEV Lower
Threshold

BSC6900

ULTHF1

AMR UL Coding Rate


adj.th1[F]

BSC6900

ULTHF2

AMR UL Coding Rate


adj.th2[F]

BSC6900

ULTHF3

AMR UL Coding Rate


adj.th3[F]

BSC6900

ULTHH1

AMR UL Coding Rate


adj.th1[H]

BSC6900

ULTHH2

AMR UL Coding Rate


adj.th2[H]

BSC6900

ULTHH3

AMR UL Coding Rate


adj.th3[H]

BSC6900

ULTHWB1

AMR UL Coding Rate


adj.th1[WB]

BSC6900

ULTHWB2

AMR UL Coding Rate


adj.th2[WB]

BSC6900

ULTOOLHOALLOW

UL to OL HO Allowed

BSC6900

ulUlAckFreq

ACK Frequency for GPRS


BSC6900
Uplink TBF

UMCROSSTALKOPTALLOW Um Interface Crosstalk


ED
Optimization Allowed

BSC6900

UMPENALTYTIMER

UmPenaltyTimer

BSC6900

UmVer

Um Interface Tag

BSC6900

UNBA

Support Balance

BSC6900

UNBLOCKRETRY

Unblock Retry

BSC6900

UnderCurAlmThdA

ANT_A ALD Under


BSC6900
Current Occur Threshold

UnderCurAlmThdB

ANT_B ALD Under


BSC6900
Current Occur Threshold

UnderCurAlmThdRET

RET ALD Under Current


Occur Threshold

BSC6900

UnderCurClrThdA

ANT_A ALD Under


Current Clear Threshold

BSC6900

UnderCurClrThdB

ANT_B ALD Under


Current Clear Threshold

BSC6900

UnderCurClrThdRET

RET ALD Under Current


Clear Threshold

BSC6900

UPBTSID

Up BTS Index

BSC6900

UPBTSID

Dest Father BTS Index

BSC6900

UPBTSIDTYPE

UPBTS Index type

BSC6900

UPBTSIDTYPE

Dest Father Index Type

BSC6900

UPBTSNAME

Up BTS Name

BSC6900

UPBTSNAME

Dest Father BTS Name

BSC6900

UPDATE

Update

BSC6900

UPDEFAULTCS

Uplink Default CS Type

BSC6900

UPDEFAULTMCS

Uplink Default MCS Type BSC6900

UPDYNCHNTRANLEV

Uplink Multiplex
Threshold of Dynamic
Channel Conversion

UPE2ADEFAULTMCS

Uplink EGPRS2-A Default


BSC6900
MCS Type

UPE2AFIXMCS

Uplink EGPRS2-A Fixed


MCS Type

BSC6900

UPEXTTBFINACTDELAY

Inactive Period of
Extended Uplink TBF

BSC6900

UPFIXCS

Uplink Fixed CS Type

BSC6900

UPFIXMCS

Uplink Fixed MCS Type

BSC6900

UPINTERFQUALLIMIT

Interf.of UL Qual.
Threshold

BSC6900

BSC6900

UPINTERLEVLIMIT

Interf.of UL Level
Threshold

BSC6900

UPLNKMAXLENGTH

Uplink Max Length

BSC6900

UPOMLWS

OML/ESL/EML LAPD
Uplink Window Size

BSC6900

UPPCEN

UL PC Allowed

BSC6900

UPPERGRPID

Upper Class Transport


Resource Group No.

BSC6900

UPPERLP

The Upper logic port


number

BSC6900

UPRXLEVLASTTIME

Duration of Uplink
Received Level Differ

BSC6900

UPRXLEVSMOOTHPARA

Smooth Factor of Uplink


Received Level

BSC6900

UPRXLEVSTATICTIME

Observe Time of UL RX
Level Difference

BSC6900

UPSENDSMDIS

Short Message Uplink


Disabled

BSC6900

UPTBFRELDELAY

Release Delay of Nonextended Uplink TBF

BSC6900

UPTHDCSDEGRADE1

Uplink TBF Threshold


from CS2 to CS1

BSC6900

UPTHDCSDEGRADE2

Uplink TBF Threshold


from CS3 to CS2

BSC6900

UPTHDCSDEGRADE3

Uplink TBF Threshold


from CS4 to CS3

BSC6900

UPTHDCSUPGRADE1

Uplink TBF Threshold


from CS1 to CS2

BSC6900

UPTHDCSUPGRADE2

Uplink TBF Threshold


from CS2 to CS3

BSC6900

UPTHDCSUPGRADE3

Uplink TBF Threshold


from CS3 to CS4

BSC6900

URGENTRESELALLOW

Cell Urgent Reselection


Allowed

BSC6900

USERIDTYPE

User Query Type

BSC6900

USFGRAN4BLK

Support USF Granularity


4 Switch

BSC6900

USR

User Name of FTP Server BSC6900

USR

FTPServer User

BSC6900

USTBGNTIME

Energy Saving Start


Time[HH:MM]

BSC6900

USTENDTIME

Energy Saving End


Time[HH:MM]

BSC6900

UTEMTHD

Upper Temperature
Threshold

BSC6900

UTOOFAILMAXTIME

MaxRetry Time after


UtoO Fail

BSC6900

UTOOHOPENTIME

Penalty Time of UtoO HO BSC6900

UTOORECTH

UtoO HO Received Level


BSC6900
Threshold

UTOOTRAFHOALLOW

UtoO Traffic HO Allowed

UTRAFHOPERIOD

Underlay HO Step Period BSC6900

UTRAFHOSTEP

Underlay HO Step Level

BSC6900

UTRANCELLTYPE

Utran Cell Type

BSC6900

VENDORCODE

Vendor Code

BSC6900

BSC6900

VGCSMAXNUM

Maximum Number of
Channels for VGCS

BSC6900

VGCSPREEMPT

Channel Allocation
Strategy for VGCS

BSC6900

VGCSRSRVNUM

Reserved Number of
Channels for VGCS

BSC6900

VIPACCESSCPURATE

VIP Access CPU Rate

BSC6900

VIPCELL

VIP Cell

BSC6900

VIPPRIORITY

VIP Priority

BSC6900

VIPSHAREINCPURATE

VIP Share in CPU Rate

BSC6900

VLANFlAG

VLANID Flag

BSC6900

VLANFLAG

Vlan Flag

BSC6900

VLANFLAG1

VLANID Flag of First Local


BSC6900
IP address

VLANFlAG2

VLANID Flag of Second


Local IP address

BSC6900

VLANID

VLAN ID.

BSC6900

VLANID

VLAN ID

BSC6900

VLANID

VLAN ID

BSC6900

VLANID

VLAN ID

BSC6900

VLANID1

VLAN ID of First Local IP


address

BSC6900

VLANID2

VLAN ID of Second Local


BSC6900
IP address

VLANPRI

VLAN Priority

BSC6900

VLANPRI

VLAN Priority

BSC6900

VLANSWITCH

VLAN Switch

BSC6900

VOICEVER

Speech Version

BSC6900

VOL24_MASK

Enable Alarm Reporting


for 24V Power

BSC6900

VOL24_THD_HIGH

Upper Limit of Alarm for


24V Power

BSC6900

VOL24_THD_LOW

Lower Limit of Alarm for


24V Power

BSC6900

VOL48_MASK

Enable Alarm Reporting


for 48V Power

BSC6900

VOL48_THD_HIGH

Upper Limit of Alarm for


48V Power

BSC6900

VOL48_THD_LOW

Lower Limit of Alarm for


48V Power

BSC6900

VSWRENABLED

Standing Wave Alarm


CFG Enabled

BSC6900

VSWRERRTHRES

VSWR TRX Unadjusted


Threshold

BSC6900

VSWRFILETERCOUNTER

Serious VSW Alarm Filter


BSC6900
Times

VSWRTHRES1

Standing Wave Radio


Alarm Threshold

BSC6900

VSWRTHRES2

Serious VSW Alarm


Threshold

BSC6900

VSWRUNJUSTTHRES

VSWR TRX Error


Threshold

BSC6900

VVer

V-Version No.

BSC6900

WAITFORRELIND

T3109

BSC6900

WAITFORRELINDAMRFR

Wait for REL Indication


AMR FR

BSC6900

WAITFORRELINDAMRHR

T3109 for AMR HR

BSC6900

WaitMSLocationResponse

Timer of MS Location
Response from MS

BSC6900

WAITRESVCHANREFRESH Timer of Reserved TCH


TIMER
for EMC

BSC6900

WAITSDCCHIDLETIMER

IBCA Wait SDCCH Idle


Timer

BSC6900

WaitSMLCLocationRespon Timer of MS Location


se
Response from SMLC

BSC6900

WARMSET

Heating Equipment

BSC6900

WATER_MASK

Enable Water Alarm


Reporting

BSC6900

WEEK

Week Limit

BSC6900

WELONGI

WE Longitude

BSC6900

WETSET

Humidification
Equipment

BSC6900

WHETHERAFFECTSWAP

Whether affect the port


swapping

BSC6900

WINADJSWITCH

LAPD Window Adjust


Switch

BSC6900

WK

Week

BSC6900

WKMODE

Work mode

BSC6900

WLAETIME

End Time of WLA


Detection

BSC6900

WLAFLAG

Wireless Link Alarm


Critical Permit

BSC6900

WLARP

WLA Prompting Recover


Period

BSC6900

WLASTIME

Begin Time of WLA


Detection

BSC6900

WLNKALMFLAG

Wireless Link Alarm Flag BSC6900

WORKAREA

Work Area Flag

BSC6900

WORKINGSTANDARD

Working Standard

BSC6900

WORKMODE

Work Mode

BSC6900

WORKMODE

Work Mode

BSC6900

WORKMODE

Work Mode

BSC6900

WS

Window Size

BSC6900

WTBS

Wait Time before OML


Switch

BSC6900

WTBS

Ring I Wait Time Before


Switch

BSC6900

WTRT

WTR Time[Sec]

BSC6900

ZONET

TimeZone

BSC6900

MML Command
SET GCELLHOAD(Optional)

SET GCELLHOAD(Optional)

SET GCELLHOAD(Optional)

ADD BTS(Optional)

SET GCELLCCCH(Optional)

SET BSCTMR(Optional)

SET BSCTMR(Optional)

SET BTSOTHPARA(Optional)

SET BTSOTHPARA(Optional)

SET BSSLS(Optional)

SET
BTSFLEXABISPARA(Optional)

SET GCELLPSCHM(Optional)

SET BSCBASIC(Optional)

ADD AISSCFG(Optional)

SET OTHSOFTPARA(Optional)

SET GCELLPSBASE(Optional)

SET GCELLPRACH(Optional)

SET
GCELLCCBASIC(Optional)

SET
GCELLCCBASIC(Mandatory)
SET GCELLHOIUO(Optional)
ADD
BSCACCCTRLP(Mandatory)
SET
GCELLPSOTHERPARA(Option
al)
ADD
BSCACCCTRLP(Optional)
ADD
BSCACCCTRLP(Optional)
ADD
BSCACCCTRLP(Optional)

ADD BTSPPPLNK(Optional)
ADD BTSMPGRP(Optional)
IMP BTSPPPLNK(Optional)
IMP BTSMPGRP(Optional)

ADD PPPLNK(Optional)
ADD MPGRP(Optional)

SET
BSCPSSOFTPARA(Optional)

SET GCELLIDLEAD(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLSOFT(Optional)

ADD AISSCFG(Optional)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)

SET GCELLSOFT(Optional)

SET
SET
SET
SET
SET

BTSFMUABP(Optional)
BTSAPMUBP(Optional)
BTSDATUBP(Optional)
BTSDEMUBP(Optional)
BTSDHEUBP(Optional)

SET
BSCPSSOFTPARA(Optional)
SET
BSCPSSOFTPARA(Optional)

SET BTSRXUBP(Optional)

ADD EXTNCELL(Mandatory)
COL
BSCSYNCINFO(Mandatory)

SET
BTSEXCURSION(Mandatory)
SET
BSCSYNCOFF(Mandatory)

SET
GCELLEGPRSPARA(Optional)

SET
BTSAUTODLDACTINFO(Optio
nal)

SET
BTSAUTODLDACTINFO(Optio
nal)

SET
GCELLADMSTAT(Mandatory)

SET
GTRXADMSTAT(Mandatory)

SET
GTRXCHANADMSTAT(Mandat
ory)

ADD AISSCFG(Optional)

ADD AISSCFG(Optional)

ADD AISSCFG(Mandatory)

ADD AISSCFG(Optional)
ADD
BTSALMMGMRULE(Mandator
y)

SET
BTSAUTODLDACTINFO(Optio
nal)

SET
BTSAUTODLDACTINFO(Optio
nal)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET
GCELLCCBASIC(Optional)

SET
GCELLCCBASIC(Optional)
ADD GPS(Mandatory)
ADD GPS(Mandatory)

SET
GCELLCCBASIC(Optional)

SET
GCELLCCBASIC(Optional)

SET ALMPORT(Mandatory)
SET
ALMBLKPARA(Mandatory)
SET ALMLVL(Mandatory)
SET ALMSHLD(Mandatory)
SET BOXRPT(Mandatory)
ADD OBJALMSHLD(Optional)
SET
ENVALMPARA(Mandatory)
ADD
BTSOBJALMSHLD(Mandatory
)
SET
BTSENVALMPORT(Optional)

SET GCELLSOFT(Optional)

ADD OBJALMSHLD(Optional)
ADD
BTSOBJALMSHLD(Mandatory
)
SET
OTHSOFTPARA(Mandatory)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCBASIC(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET BSCNSPARA(Optional)

SET BSCNSPARA(Optional)

ADD RSCGRP(Mandatory)

SET
BSCPSSOFTPARA(Optional)
SET GCELLPSCHM(Optional)

SET
GCELLCHMGBASIC(Optional)

SET
BSCPSSOFTPARA(Optional)
SET
GCELLNC2PARA(Optional)

SET
GCELLCHMGBASIC(Optional)

ADD AE1T1(Mandatory)

ADD PBE1T1(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)
ADD
BTSALMMGMRULE(Mandator
y)

SET BTSAPMUBP(Optional)
SET BTSDPMUBP(Optional)
SET
BTSALMFLASHTHD(Mandato
ry)
ADD
BTSALMMGMRULE(Mandator
y)
SET BTSDGPSBP(Optional)

SET BTSDGPSBP(Optional)

SET BTSDGPSBP(Optional)
ADD
BTSALMMGMRULE(Mandator
y)

SET
BTSALMFLASHTHD(Optional)

SET
BTSALMFLASHTHD(Optional)

SET
BTSALMFLASHTHD(Optional)

SET
BTSALMFLASHTHD(Optional)

SET BTSDHEUBP(Optional)
EXP ALMLOG(Optional)
STA ALMLOG(Optional)

SET
GCELLPSPWPARA(Optional)

SET GCELLLCS(Optional)
ADD GPS(Mandatory)
SET GCELLLCS(Optional)
ADD GPS(Mandatory)

EXP ALMLOG(Optional)

SET ALMLVL(Mandatory)
SET ALMSCRN(Mandatory)
SET ENVALMPARA(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR3(Optional)

SET GCELLCCAMR(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET
GCELLPWRBASIC(Optional)
SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET GCELLCCAMR(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET OTHSOFTPARA(Optional)

SET AITFOTHPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET
BTSANTANGLE(Mandatory)

ADD ADJNODE(Mandatory)
ADD IPPATH(Mandatory)
ADD ADJMAP(Mandatory)
ADD IPMUX(Mandatory)
ADD
IPPATHBIND(Mandatory)
SET ENVALMPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET TCPARA(Optional)

SET GCELLLCS(Optional)

SET BTSDGPSBP(Optional)
SET BTSUSCUBP(Optional)

SET BTSDGPSBP(Optional)
SET BTSUSCUBP(Optional)

ADD MPGRP(Optional)

SET BTSTHEFTALM(Optional)

LOD RETANTCFG(Mandatory)
SET
BTSANTANGLE(Mandatory)
SET RETANTENB(Mandatory)

ADD
BTSBINDLOCGRP(Optional)
ADD
TRXBIND2PHYBRD(Mandator
y)
ADD
BTSANTFEEDERBRD(Mandat
ory)
SET
BTSANTFEEDERCONNECT(O
ptional)
ADD MTP3LNK(Mandatory)

ADD SCTPLNK(Mandatory)

ADD SEMILINK(Mandatory)
SET
BSCPSSOFTPARA(Optional)
SET
BSCPSSOFTPARA(Optional)
SET
BSCPSSOFTPARA(Optional)

SET
BSCPSSOFTPARA(Optional)

SET
BSCPSSOFTPARA(Optional)
SET
BSCPSSOFTPARA(Optional)
SET
BSCPSSOFTPARA(Optional)
SET
BSCPSSOFTPARA(Optional)
SET BSCBASIC(Optional)
CMP BRDAREA(Optional)
LOD PATCH(Optional)
LOD BRD(Optional)
SYN BRDAREA(Optional)

SET GTRXRLALM(Optional)

SET GTRXRLALM(Optional)

SET GTRXRLALM(Optional)

STR IPCHK(Optional)

STR IPCHK(Optional)
ADD MTP3LNK(Mandatory)
ADD ATERSL(Optional)
ADD ATERCONSL(Optional)
ADD MTP3LNK(Mandatory)
EXP ALMLOG(Optional)
STA ALMLOG(Optional)

SET ENVALMPARA(Optional)

SET GCELLHOAD(Optional)

SET
GCELLCCBASIC(Optional)

SET
GCELLCHMGAD(Optional)

SET BTSAPMUBP(Optional)
SET BTSDEMUBP(Optional)
SET BTSDHEUBP(Optional)

SET BTSRXUBP(Mandatory)

SET BTSAPMUBP(Optional)
SET BTSDEMUBP(Optional)
SET BTSDHEUBP(Optional)

SET BTSRXUBP(Mandatory)

SET BTSAPMUBP(Optional)
SET BTSDEMUBP(Optional)
SET BTSDHEUBP(Optional)

SET BTSRXUBP(Mandatory)

SET OTHSOFTPARA(Optional)

SET GCELLTMR(Optional)

SET BSCTMR(Optional)

SET BSCAITFTMR(Optional)

SET BSCAITFTMR(Optional)

SET BSCAITFTMR(Optional)

SET BSCTMR(Optional)

SET BSCTMR(Optional)

SET BSCAITFTMR(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

ADD MTP3LNK(Mandatory)
ADD ATERE1T1(Mandatory)
ADD
ATERCONPATH(Optional)
ADD ATERSL(Mandatory)
ADD
ATERCONSL(Mandatory)
ADD SEMILINK(Mandatory)

SET BSSLS(Optional)

ADD MTP3LNK(Mandatory)
ADD ATERSL(Mandatory)
ADD
ATERCONSL(Mandatory)

ADD SEMILINK(Mandatory)

ADD ATEROML(Mandatory)

ADD ATEROML(Mandatory)
ADD ATERSL(Optional)
ADD ATERCONSL(Optional)
SET BSCBASIC(Mandatory)

STR BTSVSWRTST(Optional)

ADD MTP3LNK(Mandatory)

SET
GCELLIDLEBASIC(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET E1T1LOP(Optional)

STR E1T1TST(Optional)

ADD BTSPPPLNK(Mandatory)
ADD BTSMPGRP(Mandatory)
IMP BTSPPPLNK(Mandatory)
IMP BTSMPGRP(Mandatory)

ADD PPPLNK(Mandatory)

ADD MPGRP(Mandatory)
SET
SSLAUTHMODE(Mandatory)

ADD BTSPPPLNK(Mandatory)
ADD BTSMPGRP(Mandatory)
IMP BTSPPPLNK(Mandatory)
IMP BTSMPGRP(Mandatory)

ADD PPPLNK(Mandatory)

ADD MPGRP(Mandatory)

ADD BTSPPPLNK(Mandatory)
ADD BTSMPGRP(Mandatory)
IMP BTSPPPLNK(Mandatory)
IMP BTSMPGRP(Mandatory)

ADD PPPLNK(Mandatory)

ADD MPGRP(Mandatory)

ADD BTSPPPLNK(Optional)
ADD BTSMPGRP(Optional)
IMP BTSPPPLNK(Optional)
IMP BTSMPGRP(Optional)

ADD PPPLNK(Optional)

ADD MPGRP(Optional)

SET ETHPORT(Optional)

ADD BRD(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET OTHSOFTPARA(Optional)

SET BTSETHPORT(Optional)

SET
BTSAUTODLDACTINFO(Optio
nal)

LCK SCHTSK(Optional)

SET PWDPOLICY(Optional)

SET OPT(Optional)

SET BSCBASIC(Optional)

SET ALMPORT(Optional)
SET
BTSENVALMPORT(Optional)

SET OPT(Optional)

SET OPT(Optional)

SET OPT(Optional)

SET OPT(Optional)

SET CLK(Optional)

SET CLK(Optional)

BKP DB(Optional)

BKP LOGDB(Optional)

SET GCELLSOFT(Optional)

SET
BSCPSSOFTPARA(Optional)

ADD BTSESN(Optional)

STR IPCHK(Optional)

STR IPCHK(Optional)

SET
BTSBAKPWR(Mandatory)

SET BTSBAKPWR(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLHOAD(Optional)

SET BTSRACKBC(Mandatory)

ADD AISSCFG(Mandatory)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)
SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET SCTPSRVPORT(Optional)

SET GTRXRLALM(Optional)

SET BTSAPMUBP(Optional)

ADD GCELL(Optional)

ADD
GEXT2GCELL(Mandatory)
ADD
GCELLQUICKSETUP(Optional
)
ADD
GEXT2GCELL(Mandatory)
ADD
GCELLQUICKSETUP(Mandato
ry)
SET
GCELLHOPQUICKSETUP(Man
datory)
SET
BSCPSSOFTPARA(Optional)
SET
BSCPSSOFTPARA(Optional)

SET
BSCPSTCDSCPMAP(Optional)
STR
FRPORTLOOP(Mandatory)
BLK BC(Mandatory)
ADD BC(Mandatory)
ADD NSVC(Mandatory)

SET BTSAPMUBP(Optional)

SET BTSAPMUBP(Optional)

SET BTSAPMUBP(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

ADD N7DPC(Mandatory)

SET GBSCREDGRP(Optional)

SET
GCELLEGPRSPARA(Optional)
SET
GCELLCCUTRANSYS(Optiona
l)
SET
GCELLHOUTRANFDD(Option
al)
SET
GCELLHOUTRANTDD(Option
al)
SET
GCELLHOBASIC(Optional)

ADD G2GNCELL(Optional)

ADD G2GNCELL(Optional)

STR IPCHK(Optional)
ADD BTSBFD(Mandatory)
ADD
BTSIPRTBIND(Mandatory)

SET GTRXRLALM(Optional)

SET
GCELLCCACCESS(Optional)

SET
BTSEXCURSION(Mandatory)
SET
BSCSYNCOFF(Mandatory)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET ALMBLKSW(Optional)

SET ALMBLKPARA(Optional)

SET ALMBLKSW(Optional)

SET ALMBLKSW(Optional)

SET BSCNSPARA(Optional)

SET BSCNSPARA(Optional)
ADD
ATERCONPATH(Mandatory)
ADD
ATERCONPATH(Mandatory)
ADD
ATERCONPATH(Mandatory)

SET BSCTMR(Optional)

ADD PPPLNK(Mandatory)
ADD MPGRP(Mandatory)

SET BOXRPT(Mandatory)
SET
BTSBREAKPOINT(Optional)
SET
BTSBREAKPOINT(Optional)

SET
GCELLHOBASIC(Optional)

ADD G2GNCELL(Optional)

ADD G2GNCELL(Optional)

ADD G2GNCELL(Optional)

STR BKP(Mandatory)

SET FCSW(Mandatory)
SET FCCPUTHD(Mandatory)
SET
FCMSGQTHD(Mandatory)

SET CPUTHD(Mandatory)

ADD BRD(Mandatory)

STR BTSLOG(Mandatory)

STR BTSVSWRTST(Optional)
ADD
BTSBRDCAP(Mandatory)
ADD BTSRXUBRD(Optional)

LOD BTSSW(Mandatory)

ADD
BTSBRDCAP(Mandatory)
ADD BTSRXUBRD(Optional)
SET
DPUBRDTYPE(Mandatory)
ADD BRD(Optional)
SET ETHPORT(Mandatory)
ADD PPPLNK(Mandatory)

ADD MPGRP(Mandatory)

ADD MPLNK(Mandatory)
ADD
BTSBRDCAP(Mandatory)

STR BTSLOG(Mandatory)

SET BTSRINGATTR(Optional)

SET GCELLSBC(Optional)

SET GCELLSBC(Optional)

BKP LOGDB(Optional)

SET
GCELLIDLEBASIC(Optional)

ADD EXTBSC(Mandatory)

SET BSCDSTPA(Optional)
BLK ACIC(Mandatory)
ADD AE1T1(Mandatory)
ADD GCBSADDR(Mandatory)

ADD AISSCFG(Optional)

ADD AISSCFG(Optional)

ADD ADJNODE(Mandatory)
ADD GEXT2GCELL(Optional)
ADD EXTBSC(Mandatory)
ADD AISSCFG(Optional)

ADD
BTSAUTOPLAN(Mandatory)
SET BTSIP(Optional)
IMP BTSIPPARA(Mandatory)

ADD GCBSADDR(Mandatory)

SET BSSLS(Optional)

ADD EXTBSC(Mandatory)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)
ADD
BTSMONITORTS(Mandatory)

ADD GCBSADDR(Mandatory)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)
ADD
BTSMONITORTS(Mandatory)
ADD
BTSMONITORTS(Mandatory)

ADD
BTSMONITORTS(Mandatory)

SET BSCAISS(Mandatory)

ADD ATERE1T1(Mandatory)
ADD ATERSL(Mandatory)
ADD SEMILINK(Mandatory)

SET BSCBASIC(Mandatory)
ADD
BTSMONITORTS(Mandatory)

SET GCELLPSBASE(Optional)

SET GCELLHOCTRL(Optional)

ADD GCELL(Optional)

SET
GCELLIDLEBASIC(Optional)

ADD GCELL(Optional)

ADD GCELL(Optional)

SET BSSLS(Optional)

ADD GCNNODE(Optional)

SET GCELLPSBASE(Optional)

SET CLK(Mandatory)

CON PATCH(Mandatory)
LOD PATCH(Mandatory)
LOD BRD(Mandatory)
SET E1T1LOP(Mandatory)
SET E1T1(Mandatory)
LOP E1T1(Mandatory)
STR E1T1TST(Mandatory)
SET OPT(Mandatory)
SET COPTLNK(Mandatory)
ADD
IPLOGICPORT(Mandatory)

CHK E1T1CRS(Mandatory)
ADD
BTSANTFEEDERBRD(Mandat
ory)

ADD BTSBRD(Mandatory)

ADD
BTSRXUBRD(Mandatory)
ADD
BTSTRXBRD(Mandatory)

SET
BTSANTFEEDERCONNECT(M
andatory)

ADD BTSRETANT(Mandatory)

ADD ATERSL(Mandatory)

ADD ATERE1T1(Mandatory)

SET
GCELLBASICPARA(Optional)

SET
BTSOMLDETECT(Mandatory)

SET BTSIP(Optional)

IMP BTSIPPARA(Mandatory)

ADD BTS(Optional)

SET BTSOTHPARA(Optional)

ADD ADJNODE(Mandatory)

BTSBINDLOCGRP(Mandatory
)
ADD
BTSSFPMODE(Mandatory)
ADD
BTSANTFEEDERBRD(Mandat
ory)
ADD BTSBRD(Mandatory)
ADD
BTSCABINET(Mandatory)
ADD
BTSRXUBRD(Mandatory)
ADD
BTSTRXBRD(Mandatory)
SET
BTSENVALMPORT(Mandatory
)
ADD
BTSALMMGMRULE(Mandator
y)
SET
BTSANTFEEDERCONNECT(M
andatory)
ADD
BTSOBJALMSHLD(Mandatory
)
SET
BTSFORBIDTS(Mandatory)
SET BTSIDLETS(Mandatory)
SET BTSOMLTS(Mandatory)
TID BTSABISTS(Mandatory)
ADD BTSIPRT(Mandatory)
SET
BSCABISPRIMAP(Mandatory)
ADD
BTSABISHDLCPATH(Mandato
ry)
LOD BTSSW(Mandatory)
LOD BTSPATCH(Mandatory)
CON BTSPATCH(Mandatory)

SET
BTSANTANGLE(Mandatory)
COL SYNCINFO(Mandatory)

ADD BTSOP(Mandatory)

ADD
BTSAUTOPLAN(Mandatory)
SET BTSIP(Optional)
IMP BTSIPPARA(Mandatory)

SET BSSLS(Optional)

ADD
BTSAUTOPLAN(Mandatory)

SET GCELLHOCTRL(Optional)

ADD
BTSBINDLOCGRP(Mandatory
)
ADD
BTSSFPMODE(Mandatory)
ADD
BTSANTFEEDERBRD(Mandat
ory)
ADD BTSBRD(Mandatory)
ADD
BTSCABINET(Mandatory)
ADD
BTSRXUBRD(Mandatory)
ADD
BTSTRXBRD(Mandatory)
SET
BTSENVALMPORT(Mandatory
)
ADD
BTSALMMGMRULE(Mandator
y)
SET
BTSANTFEEDERCONNECT(M
andatory)
ADD
BTSOBJALMSHLD(Mandatory
)
SET
BTSFORBIDTS(Mandatory)
SET BTSIDLETS(Mandatory)
SET BTSOMLTS(Mandatory)
TID BTSABISTS(Mandatory)
ADD BTSIPRT(Mandatory)
ADD
BTSABISHDLCPATH(Mandato
ry)
LOD BTSSW(Mandatory)
LOD BTSPATCH(Mandatory)
CON BTSPATCH(Mandatory)

SET BTSPINGSW(Optional)

SET
BTSLOCKBCCH(Mandatory)

SET GCELLPWR2(Optional)

SET GCELLSOFT(Optional)

LOD BTSSW(Mandatory)

SET BTSTRCMPR(Mandatory)

ADD
BTSAUTOPLAN(Mandatory)
SET
BTSAUTOPLANCFG(Mandato
ry)

ADD BTS(Mandatory)
SET BTSALM(Mandatory)

LOD BTSPATCH(Mandatory)
CON BTSPATCH(Mandatory)

ADD BTSBFD(Optional)

STR BTSTST(Mandatory)

SET BTSAPMUBP(Optional)

SET BTSRINGATTR(Optional)

ADD SCTPLNK(Optional)
ADD PTPBVC(Mandatory)
BLK PTPBVC(Mandatory)
ADD
GCELLQUICKSETUP(Optional
)
SET BSSGPPARA(Optional)

ADD
IPLOGICPORT(Mandatory)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)
ADD TRMLOADTH(Optional)
ADD TRMLOADTH(Optional)
ADD IPLOGICPORT(Optional)

ADD RSCGRP(Mandatory)

ADD IPLOGICPORT(Optional)

SET GTRXRLALM(Optional)

ADD NCELL(Mandatory)
COL SYNCINFO(Mandatory)
SET
GCELLRESELECTPARA(Optio
nal)
SET
GCELLRESELECTPARA(Optio
nal)
ADD BTSCABINET(Optional)

SET BTSRACKBC(Mandatory)
ADD CAB(Mandatory)

SET
GCELLBASICPARA(Optional)

SET
BTSCLKPARA(Mandatory)

SET GCELLCCCH(Optional)

SET
BTSAUTOPLANCFG(Optional)

ADD BTSBRD(Optional)

ADD IPPATH(Optional)
ADD IPLOGICPORT(Optional)
STR IPCHK(Optional)

SET
GCELLIDLEBASIC(Optional)

ADD GCBSADDR(Mandatory)
ADD GCBSADDR(Mandatory)

ADD GCBSADDR(Optional)

ADD GCBSADDR(Mandatory)

SET BSCTMR(Optional)

SET
GCELLIDLEBASIC(Optional)

ADD IPLOGICPORT(Optional)

SET BSCTMR(Optional)

SET
GCELLHOFITPEN(Optional)

SET
GCELLHOFITPEN(Optional)

SET BSCBASIC(Optional)

SET CERTFILE(Optional)

SET GCELLCCCH(Optional)

SET GCELLCCCH(Optional)

SET
BSCPSTCDSCPMAP(Optional)
ADD ETHMA(Optional)

SET GCELLOTHEXT(Optional)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELL2GBA1(Mandatory)

SET
GCELL2GBA1(Mandatory)

SET
GCELLHO2GBA2(Mandatory)

SET
GCELLHO2GBA2(Mandatory)

SET
GCELLBASICPARA(Optional)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLSERVPARA(Optional)

SET GCELLOTHEXT(Optional)

SET BTSPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSPMUBP(Optional)

SET BTSDPMUBP(Optional)

ry)
SET
GCELLHOEMG(Mandatory)
SET
GCELLHOFAST(Mandatory)
SET
GCELLHOFDDBA2(Mandator
y)
SET
GCELLHOFITPEN(Mandatory)
SET
GCELLHOIUO(Mandatory)
SET
GCELLHOPTP(Mandatory)
SET
GCELLHOTDDBA2(Mandator
y)
SET
GCELLHOUTRANFDD(Mandat
ory)
SET
GCELLHOUTRANTDD(Mandat
ory)
SET GCELLPWR2(Mandatory)
SET GCELLPWR3(Mandatory)
SET
GCELLDYNTURNOFF(Mandat
ory)
SET
GCELLPWRBASIC(Mandatory
)
SET
GCELLCHMGAD(Mandatory)
SET GMRSCOPE(Mandatory)

ADD BTSRETANT(Mandatory)
ADD
BTSAUTOPLAN(Optional)
SET
GCELLHOINTERRATLDB(Man
datory)
SAV
GCELLTEMPLATE(Mandatory)

STR NCS(Mandatory)

SET FHO(Mandatory)

ADD BTSRETANT(Mandatory)
SET
BTSANTANGLE(Mandatory)
ADD GCELL(Mandatory)

ADD GEXT3GCELL(Optional)

ADD GSMSCB(Optional)

SET
MSGSOFTPARA(Optional)

SET
GCELLCHMGBASIC(Optional)

GCELLHOEDBPARA(Mandato
ry)
SET
GCELLHOEMG(Mandatory)
SET
GCELLHOFAST(Mandatory)
SET
GCELLHOFDDBA2(Mandator
y)
SET
GCELLHOFITPEN(Mandatory)
SET
GCELLHOIUO(Mandatory)
SET
GCELLHOPTP(Mandatory)
SET
GCELLHOTDDBA2(Mandator
y)
SET
GCELLHOUTRANFDD(Mandat
ory)
SET
GCELLHOUTRANTDD(Mandat
ory)
SET GCELLPWR2(Mandatory)
SET GCELLPWR3(Mandatory)
SET
GCELLDYNTURNOFF(Mandat
ory)
SET
GCELLPWRBASIC(Mandatory
)
SET
GCELLHOINTERRATLDB(Man
datory)
ADD
BTSAUTOPLAN(Mandatory)
SAV
GCELLTEMPLATE(Mandatory)

ADD GSMSCB(Optional)

SET
GCELLCHMGAD(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLSOFT(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET
GCELLNC2PARA(Optional)

SET
GCELLNC2PARA(Optional)

SET
GCELLBASICPARA(Optional)

SET GCELLCCAD(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)
SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)
SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)
SET BTSDPMUBP(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GTRXFC(Optional)

SET CERTFILE(Mandatory)

SET BTSIP(Optional)

SET BTSFMUABP(Mandatory)
SET BTSNFCBBP(Mandatory)
SET BTSPMUBP(Mandatory)
SET BTSAPMUBP(Mandatory)
SET BTSDATUBP(Mandatory)
SET
BTSDEMUBP(Mandatory)
SET BTSDHEUBP(Mandatory)
SET
BTSDOMUBP(Mandatory)
SET BTSDPMUBP(Mandatory)
SET BTSDTMUBP(Mandatory)
SET BTSPSUFP(Mandatory)
SET BTSDDPUBP(Mandatory)
SET BTSUSCUBP(Mandatory)

SET
BTSAUTOPLANCFG(Mandato
ry)

IMP
IMP
IMP
IMP
IMP
IMP
IMP

BTSIPPARA(Mandatory)
BTSVLAN(Mandatory)
BTSDEVIP(Mandatory)
BTSPPPLNK(Mandatory)
BTSMPGRP(Mandatory)
BTSMPLNK(Mandatory)
BTSIPRT(Mandatory)

SET
BTSCABPARA(Mandatory)
SET
BTSPOWERTYPE(Mandatory)
ADD OP(Mandatory)
ADD CCG(Mandatory)
SET CCGN(Mandatory)

ADD OP(Optional)

ADD ATERSL(Optional)
ADD ATERCONSL(Optional)

ADD PBSL(Optional)

SET
BTSAUTOPLANCFG(Optional)
SET BTSIDLETS(Mandatory)

SET CCGN(Optional)

ADD ATERSL(Optional)

ADD ATERCONSL(Optional)

ADD PBSL(Optional)

ADD G2GNCELL(Optional)

CBN
BTSRXUCHAIN(Mandatory)

SET
GCELLCHMGBASIC(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSBC(Optional)
ADD GSMSCB(Mandatory)

SET
GCELLCHMGAD(Optional)

SET AITFOTHPARA(Optional)

SET GCELLSOFT(Optional)

ADD IPPATH(Optional)

SET OTHSOFTPARA(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

STR IPCHK(Optional)
ADD
IPPATHBIND(Mandatory)
SET BTSAIRCON(Optional)

SET BTSAIRCON(Optional)

ADD SCTPLNK(Optional)

ADD SCTPLNK(Optional)

ADD SCTPLNK(Optional)

STR IPCHK(Mandatory)
STR BTSTST(Mandatory)
SET
BTSCHNFALLBACK(Mandator
y)
SET TCPLYVOICE(Mandatory)

SET FHO(Mandatory)
SET
GTRXCHANHOP(Mandatory)
SET GTRXCHAN(Mandatory)
SET
GTRXCHANADMSTAT(Mandat
ory)
STR BTSTST(Mandatory)

STR BTSTST(Mandatory)

SET
BTSCHNFALLBACK(Mandator
y)

SET
MSGSOFTPARA(Optional)

SET
MSGSOFTPARA(Optional)

SET
MSGSOFTPARA(Optional)

SET
MSGSOFTPARA(Optional)
SET
MSGSOFTPARA(Optional)

SET
MSGSOFTPARA(Optional)

SET
MSGSOFTPARA(Optional)

SET
GCELLCHMGAD(Optional)

SET
GPSCHRSCOPE(Optional)
SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET GTRXCHAN(Optional)

ADD GCELL(Mandatory)
ADD
GEXT2GCELL(Mandatory)
ADD
GEXT3GCELL(Mandatory)
SET FHO(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)
SET
BTSAUTOPLANCFG(Optional)
ADD
GCELLQUICKSETUP(Mandato
ry)

SET
BTSAUTOPLANCFG(Optional)

BLK ACIC(Mandatory)

BLK PBCIC(Mandatory)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)
SET
MSGSOFTPARA(Optional)
SET
MSGSOFTPARA(Optional)

SET
MSGSOFTPARA(Optional)

SET
MSGSOFTPARA(Optional)

SET
MSGSOFTPARA(Optional)

SET
MSGSOFTPARA(Optional)

ADD IPLOGICPORT(Optional)
SET
GCELLCHMGAD(Optional)
ADD
DXXCONNECT(Mandatory)
ADD
DXXCONNECT(Mandatory)

SET GCELLGPRS(Optional)

SET OTHSOFTPARA(Optional)

ADD MPGRP(Optional)

SET
BTSCLKPARA(Mandatory)

SET BTSIPCLKPARA(Optional)

SET CLKTYPE(Mandatory)

SET BTSCLK(Mandatory)

SET BTSTHEFTALM(Optional)
EXP ALMLOG(Optional)
STA ALMLOG(Optional)
SET BTSTHEFTALM(Optional)

EXP LOG(Optional)

ADD CCG(Mandatory)

ADD SUBCMD(Mandatory)
ADD CAB(Mandatory)
ADD BTSBFD(Optional)
ADD BTSIPRTBIND(Optional)

ADD
TRXBIND2PHYBRD(Optional)
SWP BTSRING(Optional)
SWP BTSOMLLINK(Optional)
SET BTSFMUABP(Optional)
SET BTSAPMUBP(Optional)
SET BTSDATUBP(Optional)
SET BTSDEMUBP(Optional)
SET BTSDHEUBP(Optional)
SET BTSUSCUBP(Optional)
SET
BTSCABPARA(Mandatory)
SET
BTSPOWERTYPE(Mandatory)
SET BTSRXUBP(Optional)
ADD
BTSRXU2LOCGRP(Mandatory
)
ADD
BTSBINDLOCGRP(Mandatory
)
ADD BTSBRD(Optional)
ADD
BTSCABINET(Mandatory)
ADD BTSRXUBRD(Optional)
SET
BTSENVALMPORT(Optional)
ADD
BTSOBJALMSHLD(Mandatory
)

ADD BTSSFPMODE(Optional)
SET BTSFORBIDTS(Optional)
SET BTSOMLTS(Optional)
SET BTSETHPORT(Optional)
ADD BTSPPPLNK(Optional)
ADD BTSMPLNK(Optional)
ADD BTSETHMA(Optional)
ADD
BTSETHLCMEP(Optional)
ADD
BTSTOPCONFIG(Optional)
IMP BTSDEVIP(Optional)
IMP BTSPPPLNK(Optional)
IMP BTSMPLNK(Optional)

LOD RETANTCFG(Optional)
SET BTSANTANGLE(Optional)
SET BTSCLKPARA(Optional)
SET BTSCAVFRQ(Optional)
SET BTSPMUDEF(Optional)
SET BTSTMA(Optional)
SET RETANTENB(Optional)
STR BTSBATTTST(Optional)
STR BTSTST(Mandatory)
STR RETANTSCAN(Optional)
STR
TRANSPERFTST(Optional)
SWP BTSBRD(Optional)
SET BTSENVALM(Optional)
CHG
BTSPTUSHKTM(Optional)

OPR
BTSBRDPWR(Mandatory)

SET GBSCREDGRP(Optional)

ADD GCNNODE(Mandatory)

ADD NSE(Mandatory)
ADD SGSNNODE(Mandatory)
ADD
NRISGSNMAP(Mandatory)

ADD
NRIMSCMAP(Mandatory)
SET
MSGSOFTPARA(Mandatory)
SET
AITFOTHPARA(Mandatory)
SET
BSCAITFTMR(Mandatory)
ADD GCNNODE(Mandatory)

CMP LICENSE(Optional)

SET GBSCREDGRP(Optional)

EXP ALMLOG(Optional)

SET BTSBAT(Mandatory)

SET BTSDPMUBP(Mandatory)

SET LOGLIMIT(Optional)

SET ALMBLKPARA(Optional)

SET ALMBLKPARA(Optional)

SET
GCELLHOBASIC(Optional)

ADD GSMSCB(Mandatory)

SET BTSOUTPUT(Optional)

COL SYNCINFO(Mandatory)
SET
GCELLPWRBASIC(Optional)

SET
GCELLCCBASIC(Optional)

SET PWDPOLICY(Optional)

SET BTSBWPARA(Optional)

ADD GEXT2GCELL(Optional)
ADD
BTSABISHDLCPATH(Mandato
ry)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)

ADD
PORTFLOWCTRLPARA(Option
al)

SET
GCELLHOBASIC(Optional)

ADD
DXXCONNECT(Mandatory)
ADD SUBRACK(Optional)
ADD
GIURGCONN(Mandatory)
SET CONNTYPE(Mandatory)

SET GCELLHOCTRL(Optional)

SET GCELLHOAD(Optional)

PING IP(Optional)

PING MAC(Optional)
PING BTSCFM(Optional)
STR BTSTST(Mandatory)

SET GTRXDEV(Optional)

ADD GCBSADDR(Mandatory)

SET BTSCRC4(Mandatory)

SET
GCELLIDLEBASIC(Optional)

SET CERTFILE(Mandatory)

SET CERTFILE(Optional)

SET GCELLGSMR(Optional)

SET GCELLGSMR(Optional)

SET
GCELLIDLEBASIC(Optional)

SET BSCBASIC(Optional)

ADD SCTPLNK(Optional)

SET GCSCHRCTRL(Optional)

SET GCSCHRCTRL(Optional)

SET GCSCHRCTRL(Optional)

SET GCSCHRCTRL(Optional)

ADD TRMFACTOR(Optional)

ADD TRMMAP(Optional)

ADD TRMMAP(Optional)

ADD TRMFACTOR(Optional)

ADD GCELL(Optional)

SET GCSCHRCTRL(Optional)

SET GCSCHRCTRL(Optional)

SET GCSCHRCTRL(Optional)

SET GCSCHRCTRL(Optional)

SET GCSCHRCTRL(Optional)

SET
GCSCHRCTRL(Mandatory)
SET GCSCHRCTRL(Optional)

SET GTRXFC(Optional)

SET GCSCHRCTRL(Optional)

ADD TRMFACTOR(Optional)

SET GCSCHRCTRL(Optional)

ADD TRMMAP(Optional)

ADD TRMMAP(Optional)

ADD TRMFACTOR(Optional)

ADD GCELL(Optional)

SET SLFSLVSW(Optional)

ADD MTP3LNK(Optional)

ADD MTP3LNK(Optional)

ADD MTP3LNK(Optional)

ADD MTP3LNK(Optional)

ADD MTP3LNK(Optional)

ADD MTP3LNK(Optional)

ADD MTP3LNK(Optional)

ADD MTP3LNK(Optional)

ADD MTP3LNK(Optional)

SET FCCPUTHD(Optional)

SET FCMSGQTHD(Optional)

ADD AISSCFG(Mandatory)

SET GCELLPSBASE(Optional)

SET
BTSLOADCTRL(Mandatory)

ADD BTSRETANT(Mandatory)

ADD BTSRETANT(Mandatory)

ADD BTSRETANT(Mandatory)

ADD BTSRETANT(Mandatory)
ADD RSCGRP(Mandatory)
SET BTSCTRL(Mandatory)

SET BTSCTRL(Mandatory)

SET CMCTRLSW(Mandatory)
SET
MSGSOFTPARA(Optional)
SET
BTSAUTODLDACTINFO(Mand
atory)
SET GCSFILE(Optional)
UPD JTGCPLD(Mandatory)

SET
GCELLHOFITPEN(Optional)

SET
GCELLHOFITPEN(Optional)

SET GCELLOTHEXT(Optional)

SET TIME(Optional)

ADD OP(Optional)
ADD
BSCDSTPADATE(Mandatory)
SET
BTSAUTODLDACTINFO(Mand
atory)

SET BTSDHEUBP(Optional)

ADD GCELL(Mandatory)

ADD GCELL(Mandatory)

ADD GCELL(Mandatory)

ADD GCELL(Mandatory)

SET
BTSALMPORT(Mandatory)
SET
BTSALMPORT(Mandatory)
SET
BTSALMPORT(Mandatory)
SET
BTSALMPORT(Mandatory)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)

SET GCELLPSCHM(Optional)

SET GCELLTMR(Optional)

ADD M3DE(Mandatory)
ADD M3RT(Mandatory)
ADD M3LKS(Mandatory)
ADD OP(Optional)

SET BTSOUTPUT(Optional)

PING IP(Mandatory)
TRC IPADDR(Mandatory)
ADD IPRTBIND(Mandatory)

PING MAC(Mandatory)
TRC MAC(Mandatory)
PING BTSCFM(Mandatory)
TRC BTSCFM(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)
ADD
BTSCONNECT(Mandatory)
ADD
GIURGCONN(Mandatory)
ADD
GIURGCONN(Mandatory)
ADD
GIURGCONN(Mandatory)
MOV BCCH(Mandatory)

SET GCELLSOFT(Optional)

ADD BTSBFD(Optional)

SET
BTSABISTROP(Mandatory)
ADD BTSRETANT(Mandatory)
ADD BTSRETANT(Mandatory)
ADD PPPLNK(Mandatory)
ADD MPGRP(Mandatory)
ADD DEVIP(Mandatory)

ADD
GEXT3GCELL(Mandatory)
SET
GCELLHOFDDBA2(Mandator
y)
SET
GCELLHOTDDBA2(Mandator
y)
SET BTSDFCUBP(Optional)

SET BTSDFCUBP(Optional)

ADD GCNNODE(Optional)

SET FTPSSRV(Mandatory)

ADD GPS(Optional)

ADD DHCPRLY(Mandatory)
ADD DHCPRLY(Mandatory)
SET BTSDPMUBP(Optional)

SET
GCELLCHMGBASIC(Optional)

ADD SUBTSK(Mandatory)

ADD SUBTSK(Mandatory)
DLD LICENSE(Mandatory)
ULD LICENSE(Mandatory)
DLD RETANTCFG(Optional)
DLD BTSPATCH(Optional)
ULD BTSLOG(Optional)
DLD BTSSW(Optional)

SET AITFOTHPARA(Optional)

SET
GCELLBASICPARA(Optional)

SET GCELLSOFT(Optional)

SET OTHSOFTPARA(Optional)

ADD
GEXT3GCELL(Mandatory)
SET
GCELLHOFDDBA2(Mandator
y)
SET
GCELLHOTDDBA2(Mandator
y)

SET
GCELLBASICPARA(Optional)

SET
GCELLBASICPARA(Optional)

SET
GCELLBASICPARA(Optional)

SET BTSRXUBP(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

ADD NSVC(Mandatory)
SET
BSCPSSOFTPARA(Optional)
SET GCELLGPRS(Optional)

SET
GCELLHOBASIC(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET
GCELLPSOTHERPARA(Option
al)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)
SET
GCELLHOINTERRATLDB(Opti
onal)

SET GCELLPWR2(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET
GCELLHOINTERRATLDB(Opti
onal)

SET GCELLPWR2(Optional)

SET
GCELLPWRBASIC(Optional)

SET
GCELLPWRBASIC(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLHOEMG(Optional)

SET
GCELLAMRQUL(Optional)

SET
GCELLAMRQUL(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET
GCELLPWRBASIC(Optional)

SET
GCELLPWRBASIC(Optional)

SET
GCELLPRIVATEOPTPARA(Opti
onal)

SET GCELLGSMR(Optional)

SET GCELLGSMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

ADD
BTSANTFEEDERBRD(Optiona
l)
SET
BTSANTFEEDERCONNECT(O
ptional)
ADD
BTSANTFEEDERBRD(Optiona
l)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSIPCLKPARA(Mandatory)

SET GCELLPSCS(Optional)

SET
GCELLEGPRSPARA(Optional)

SET
GCELLEGPRSPARA(Optional)

SET
GCELLEGPRSPARA(Optional)

SET GCELLPSCS(Optional)

SET
GCELLEGPRSPARA(Optional)

SET
GCELLBASICPARA(Optional)

SET GCELLCCAD(Optional)

SET
GCELLPRIVATEOPTPARA(Opti
onal)

SET GCELLPSCS(Optional)

SET GCELLPSCS(Optional)

SET GCELLPSCS(Optional)

SET GCELLPSCS(Optional)

SET GCELLPSCS(Optional)

SET GCELLPSCS(Optional)

ADD EMU(Optional)

SET
GCELLPWRBASIC(Optional)

ADD N7DPC(Mandatory)
ADD N7DPC(Mandatory)
BLK ACIC(Mandatory)

ADD AE1T1(Optional)

ADD GCNNODE(Mandatory)

ADD N7DPC(Mandatory)

ADD
ADD
ADD
ADD
ADD
ADD

N7DPC(Mandatory)
MTP3RT(Mandatory)
MTP3LKS(Mandatory)
M3DE(Mandatory)
GCNNODE(Mandatory)
GEXTSMLC(Mandatory)

ADD GNRNC(Mandatory)

ADD G2GNCELL(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)

ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
ADD
PORTFLOWCTRLPARA(Option
al)
SET BTSBAKPWR(Optional)

SET BTSBAKPWR(Optional)

SET BTSBAKPWR(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLPSBASE(Optional)

SET BTSOUTPUT(Optional)

ADD MPLNK(Optional)
ADD PPPLNK(Optional)

ADD SCTPLNK(Optional)
SET PHBMAP(Mandatory)

PING IP(Optional)
SET DSCPMAP(Mandatory)

SET BTSVLAN(Optional)
IMP BTSVLAN(Optional)

SET
BSCPSSOFTPARA(Optional)

DLD TCFILE(Mandatory)

SET TCTYPE(Optional)

SET TCPLYVOICE(Mandatory)
SET TCPARA(Optional)
ADD
OBJALMSHLD(Mandatory)
SET
PSCELLTODSP(Mandatory)

SET
BSCPSSOFTPARA(Optional)

SET TZ(Optional)
ULD
BTSDEVFILE(Mandatory)

ADD BTSIPRT(Mandatory)
ADD
BTSIPRTBIND(Mandatory)
IMP BTSIPRT(Mandatory)

ADD BTSBFD(Mandatory)
ADD IPRT(Mandatory)

ADD BTSIPRT(Mandatory)
ADD
BTSIPRTBIND(Mandatory)
IMP BTSIPRT(Mandatory)

ADD IPRT(Mandatory)
ADD TSCROSS(Mandatory)

ADD TSCROSS(Mandatory)

SET
GCELLCCBASIC(Optional)

SET GCELLGSMR(Optional)
ADD
BTSANTFEEDERBRD(Mandat
ory)
SET
BTSANTFEEDERCONNECT(O
ptional)
ADD
BTSANTFEEDERBRD(Optiona
l)
SET
BTSANTFEEDERCONNECT(O
ptional)
ADD
BTSANTFEEDERBRD(Mandat
ory)
SET
BTSANTFEEDERCONNECT(O
ptional)
ADD
BTSANTFEEDERBRD(Mandat
ory)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET GCELLSOFT(Optional)

SET BTSETHPORT(Optional)

STR BTSTST(Mandatory)

STR
TRXBURSTTST(Mandatory)
STR BTSTST(Mandatory)

STR BTSTST(Mandatory)

SET GCELLPSCHM(Optional)

ADD AISSCFG(Optional)

ADD DXX(Mandatory)
ADD
DXXCONNECT(Mandatory)
ADD
DXXTSEXGRELATION(Mandat
ory)
ADD
BTSCONNECT(Mandatory)
ADD
BTSCONNECT(Mandatory)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET
GCELLBASICPARA(Optional)
SET
GCELLCHMGBASIC(Optional)
STR
TRANSPERFTST(Mandatory)
STR
TRANSPERFTST(Mandatory)
ADD
BTSABISHDLCPATH(Mandato
ry)
STR
TRANSPERFTST(Mandatory)

SET BTSCLK(Mandatory)

SET COPTLNK(Optional)

ADD
BTSTOPCONFIG(Mandatory)

SET BTSCLK(Mandatory)

ADD IPPATH(Mandatory)

ADD G3GNCELL(Optional)

ADD GEXT3GCELL(Optional)

SET
GCELLCCBASIC(Optional)

EXP ALMLOG(Optional)
STA ALMLOG(Optional)
EXP ALMLOG(Optional)

STA ALMLOG(Optional)

ADD SUBTSK(Optional)

STR BTSLOG(Optional)

SET TZ(Mandatory)

SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)

SET GCELLGPRS(Optional)

ADD G2GNCELL(Optional)

ADD G2GNCELL(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
BTSLOADCTRL(Mandatory)
SET GCELLPSBASE(Optional)

SET GCELLGPRS(Optional)

SET
GCELLNC2PARA(Optional)

SET
GCELLNC2PARA(Optional)

SET TZ(Mandatory)

SET GCELLCCAD(Optional)

ADD MTP3LKS(Optional)

ADD MPGRP(Optional)

SET
BSCABISPRIMAP(Optional)

SET
GCELLCCBASIC(Optional)

SET OTHSOFTPARA(Optional)

SET GCELLGSMR(Optional)

SET
BSCABISPRIMAP(Optional)
SET BSCSRVPRI(Optional)
SET
BSCABISPRIMAP(Optional)

SET TZ(Mandatory)

ADD EMSIP(Mandatory)

SET BTSFALLBACK(Optional)

SET BTSTMA(Mandatory)

SET
GCELLBASICPARA(Optional)

SET FTPSSRV(Optional)

SET FTPSCLT(Optional)

SET OTHSOFTPARA(Optional)

EXP ALMLOG(Optional)
STA ALMLOG(Optional)

BLK ACIC(Mandatory)

BLK PBCIC(Mandatory)

ADD
BSCDSTPADATE(Mandatory)

SET BTSDHEUBP(Optional)

ADD
BSCDSTPADATE(Mandatory)

SET BTSFORBIDTS(Optional)

SET BSCDSTPA(Optional)

BLK AE1T1(Mandatory)

BLK ATERE1T1(Mandatory)

SET
BTSFORBIDTS(Mandatory)
SET SCHTSKSW(Mandatory)

ADD SUBTSK(Optional)

SET GCELLHOIUO(Optional)

SET
GCELLPSOTHERPARA(Option
al)

ADD GCELL(Mandatory)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET GCELLHOIUO(Optional)

SET
GCELLCHMGBASIC(Optional)

ADD M3DE(Mandatory)

ADD M3LE(Mandatory)

SET GCELLHOIUO(Optional)

SET TCPARA(Optional)

EXP LOG(Optional)

SET
GCELLCCBASIC(Optional)

SET ETHPORT(Optional)
ADD PPPLNK(Optional)
ADD MPGRP(Optional)

SET ETHPORT(Optional)
ADD PPPLNK(Optional)
ADD MPGRP(Optional)
SET
BSCABISPRIMAP(Optional)
SET
BSCABISPRIMAP(Optional)
SET BSCSRVPRI(Optional)
SET
BSCABISPRIMAP(Optional)
EXP ALMLOG(Optional)

SET GCELLTMR(Optional)

SET AITFOTHPARA(Optional)

SET BTSRINGATTR(Optional)

EXP ALMLOG(Optional)

STA ALMLOG(Optional)

EXP LOG(Optional)

ADD SUBTSK(Mandatory)

RUN BATCHFILE(Optional)

COL LOG(Optional)

ADD GSMSCB(Mandatory)

SET TZ(Mandatory)

ADD OP(Mandatory)

STR BTSLOG(Optional)

EXP LOG(Optional)

ADD OP(Mandatory)

SET TZ(Mandatory)

SET TZ(Mandatory)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

SET
GCELLSERVPARA(Optional)

SET GCELLSOFT(Optional)

SET
GCELLPWRBASIC(Optional)

SET
GCELLPWRBASIC(Optional)

ADD
GEXT2GCELL(Mandatory)
ADD
GEXT2GCELL(Mandatory)
ADD
GEXT3GCELL(Mandatory)
ADD
GEXT3GCELL(Mandatory)
ADD EXTNCELL(Mandatory)

ADD EXTNCELL(Mandatory)
SET
GCELLPSOTHERPARA(Option
al)
SET BTSALM(Optional)

SET
GCELLEXTMSRPARA(Optional
)
SET
GCELLEXTMSRPARA(Optional
)

SET
GCELLEXTMSRPARA(Optional
)

ADD GCELL(Optional)

SET GCELLPSBASE(Optional)

SET GCELLGSMR(Optional)

SET GCELLGSMR(Optional)

SET GCELLGSMR(Optional)

SET
BSCABISPRIMAP(Optional)
SET
GCELLCHMGBASIC(Optional)

SET
GCELLHOFITPEN(Optional)

SET FANSPEED(Optional)

SET FANSPEED(Optional)

SET FANSPEED(Optional)

SET FANSPEED(Optional)

SET FANSPEED(Mandatory)

SET FANSPEED(Mandatory)

LOD FAN(Mandatory)

SET
GCELLBASICPARA(Optional)

SET BTSRINGATTR(Optional)

SET TCPARA(Optional)

SET BTSETHPORT(Optional)

SET ETHPORT(Optional)

SET GTRXFC(Optional)

ADD ETHTRK(Optional)

ADD MPGRP(Optional)
SET ETHPORT(Mandatory)
ADD PPPLNK(Optional)

ADD IPLOGICPORT(Optional)

ADD
PORTFLOWCTRLPARA(Manda
tory)
SET
BSCABISPRIMAP(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)
ADD BTSCONNECT(Optional)

SET GTRXFC(Optional)

ADD PPPLNK(Optional)

ADD MPLNK(Optional)

SET FCSW(Mandatory)

SET BTSAPMUBP(Optional)

SET
GCELLIDLEFDDBA1(Mandato
ry)

SET
GCELLHOFDDBA2(Mandator
y)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLIDLEFDDBA1(Mandato
ry)
SET
GCELLIDLEFDDBA1(Mandato
ry)
ADD GEXT3GCELL(Optional)
SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

ADD GEXT3GCELL(Optional)

SET
GCELLIDLEFDDBA1(Mandato
ry)

SET FCCPUTHD(Optional)

SET GCELLSOFT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLHOPTP(Optional)
SET
GCELLHOPQUICKSETUP(Man
datory)

ZIP FILE(Mandatory)

EXP LOG(Optional)

BKP LOGDB(Optional)

EXP CFGMML(Optional)
EXP
GCELLTEMPLATE(Optional)

EXP ALMLOG(Optional)

SET
GCELLNC2PARA(Optional)

EXP LOG(Optional)

SET GCELLPWR3(Optional)

SET BTSOUTPUT(Optional)

SET
BTSFLEXABISPARA(Optional)

SET
BTSALMFLASHTHD(Optional)

SET
BTSALMFLASHTHD(Optional)

SET
BTSALMFLASHTW(Optional)
SET
BTSALMFLASHTW(Optional)
SET
BTSALMFLASHTW(Optional)

ADD BTS(Optional)

ADD GCELL(Optional)

SET GCELLSOFT(Optional)

SET
BSCPSSOFTPARA(Optional)
SET
BSCPSSOFTPARA(Optional)
ADD IPLOGICPORT(Optional)

SET
BSCABISPRIMAP(Optional)

SET ETHPORT(Optional)

ADD PPPLNK(Optional)

ADD MPGRP(Optional)
ADD ETHTRK(Optional)

SET GCELLHOEMG(Optional)

SET GCELLHOEMG(Optional)

SET GCELLHOEMG(Optional)

SET GCELLHOEMG(Optional)

SET GCELLHOEMG(Optional)

SET GCELLHOEMG(Optional)

SET GCELLHOEMG(Optional)

SET GCELLHOEMG(Optional)

SET GCELLHOEMG(Optional)

SET
BSCPSSOFTPARA(Optional)

SET GCELLCCCH(Optional)

SET BTSFMUABP(Optional)

EXP CFGMML(Optional)
BKP DB(Optional)
EXP
GCELLTEMPLATE(Optional)

EXP ELABEL(Optional)
CHK DATA2LIC(Optional)
RVK LICENSE(Optional)
EXP DEVFILE(Optional)
DLD LICENSE(Mandatory)
ULD LICENSE(Mandatory)

DLD RETANTCFG(Mandatory)
EXP BTSDEVFILE(Optional)
LOD RETANTCFG(Mandatory)
ULD BTSLOG(Mandatory)
DLD BTSSW(Mandatory)

DLD BTSPATCH(Optional)

SET
BSCPSSOFTPARA(Optional)

ADD GCNNODE(Optional)

SET TCPARA(Optional)
SET
BSCPSSOFTPARA(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)
ADD
BTSAUTOPLAN(Mandatory)
ADD
BTSCONNECT(Mandatory)

ADD IPMUX(Optional)

SET
BTSAUTOPLANCFG(Optional)
SET
BTSAUTOPLANCFG(Optional)
SET
BTSAUTOPLANCFG(Optional)
ADD MPGRP(Optional)

SET GCELLOTHEXT(Optional)

SET
BTSEXCURSION(Mandatory)
SET
BSCSYNCOFF(Mandatory)

SET
GCELLBASICPARA(Optional)

ADD GTRX(Mandatory)

ADD SUBTSK(Mandatory)

EXP LOG(Mandatory)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

ADD GCELLFREQ(Optional)
ADD GCELLMAGRP(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

ADD
BTSANTFEEDERBRD(Optiona
l)

SET
GCELLCHMGAD(Optional)

SET
GCELLFREQSCAN(Optional)

SET GTRXDEV(Optional)

STR NCS(Mandatory)

SET GCELLSOFT(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLBASICPARA(Optional)

ADD
BTSAUTOPLAN(Mandatory)
ADD BTSCONNECT(Optional)
ADD
BTSAUTOPLAN(Mandatory)
ADD BTSCONNECT(Optional)

EXP LOG(Optional)

ADD ADJMAP(Mandatory)
ADD
TRMFACTOR(Mandatory)
SET
BSCABISPRIMAP(Mandatory)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)

ADD TRMLOADTH(Optional)
ADD TRMLOADTH(Optional)
ADD TRMLOADTH(Optional)
SET OTHSOFTPARA(Optional)
SET
GCELLHOINTERRATLDB(Opti
onal)
SET TCPARA(Optional)
SET
GCELLPSPWPARA(Optional)
ADD AISSCFG(Optional)

ADD AISSCFG(Optional)

ADD AISSCFG(Mandatory)

ADD AISSCFG(Optional)

SET
GCELLPSOTHERPARA(Option
al)

SET BSCBASIC(Optional)

ADD GPS(Optional)

SET GCELLGSMR(Optional)

SET GCELLGSMR(Optional)

SET
GLOBALROUTESW(Mandator
y)

SET
GCELLBASICPARA(Optional)

ADD
GCELLQUICKSETUP(Optional
)

SET GCELLGPRS(Mandatory)

SET
GCELLRESELECTPARA(Optio
nal)

SET GTRXCHAN(Optional)

SET
GCELLSERVPARA(Optional)

SET
GCELLNCRESELECTPARA(Opt
ional)

SET
GCELLNC2PARA(Optional)
SET
GCELLNCRESELECTPARA(Opt
ional)

SET BTSDGPSBP(Optional)
SET BTSUSCUBP(Optional)

ADD GPS(Optional)
SET
GCELLCHMGBASIC(Optional)
SET
BTSCHNFALLBACK(Mandator
y)
SET
BTSCHNFALLBACK(Mandator
y)

SET
GBSCREDGRP(Mandatory)

SET GBSCREDGRP(Optional)
SET
BTSFLEXABISPARA(Optional)
ADD RSCGRP(Mandatory)
SET BTSIP(Mandatory)
ADD RSCGRP(Mandatory)
SET GCELLSBC(Optional)
ADD GSMSCB(Mandatory)
ADD TRMLOADTH(Optional)
SET BSCBASIC(Optional)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLPSOTHERPARA(Option
al)

ADD
ICMPGUARD(Mandatory)

ADD
BTSAUTOPLAN(Optional)
SET BTSIP(Optional)

SET OTHSOFTPARA(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

ADD SCTPLNK(Optional)
ADD
BTSRXUCHAIN(Mandatory)

ADD G2GNCELL(Optional)

ADD G2GNCELL(Optional)

SET BTSBAT(Optional)

SET BTSBAT(Optional)

SET BSCBASIC(Optional)

SET
GCELLCHMGBASIC(Optional)

SET OTHSOFTPARA(Optional)

SET
GCELLCHMGBASIC(Optional)
SET BTSAPMUBP(Optional)

SET
GCELLCHMGAD(Optional)

SET PWDPOLICY(Optional)

SET GCELLGPRS(Optional)

SET GCELLHOIUO(Optional)

ADD
GCNOPERATOR(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET FHO(Mandatory)

SET FHO(Mandatory)

SET
GCELLHOBASIC(Optional)
SET GCELLHOEMG(Optional)
SET
GCELLHOFITPEN(Optional)
SET GCELLHOIUO(Optional)

SET GCELLHOFAST(Optional)

SET GCELLHOFAST(Optional)

SET GCELLHOFAST(Optional)

SET GCELLHOFAST(Optional)

ADD G3GNCELL(Optional)

ADD G3GNCELL(Optional)

SET
GCELLHOUTRANFDD(Option
al)

ADD G2GNCELL(Optional)

SET FHO(Mandatory)

ADD GEXT2GCELL(Optional)
SET GCELLHOFAST(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLHOUTRANFDD(Option
al)
SET
GCELLHOUTRANTDD(Option
al)

SET
GCELLHOEDBPARA(Optional)

ADD
GCELLMAGRP(Mandatory)
SET
GCELLMAIOPLAN(Mandatory
)
ADD
GCELLMAGRP(Mandatory)

SET
GCELLOTHBASIC(Optional)

SET
GCELLHOUTRANFDD(Option
al)
SET
GCELLHOUTRANTDD(Option
al)
SET OTHSOFTPARA(Optional)

ADD
GCELLHOPANTGRP(Optional)

ADD
GCELLHOPANTGRP(Mandato
ry)

SET GTRXHOP(Optional)

ADD GEXT2GCELL(Optional)
SET GCELLHOFAST(Optional)

ADD AISSCFG(Optional)

SET
GCELLHOUTRANFDD(Option
al)
SET
GCELLHOUTRANTDD(Option
al)

SET
MSGSOFTPARA(Optional)

ADD G3GNCELL(Optional)

ADD G3GNCELL(Optional)

ADD G2GNCELL(Optional)

ADD OPC(Optional)

SET BTSIP(Optional)

ADD GEXT2GCELL(Optional)
SET
GCELLHOBASIC(Optional)

SET GCELLHOFAST(Optional)

SET GCELLHOPANT(Optional)

SET
GCELLHOPANTQUICKSETUP(
Mandatory)

ADD
BTSRXUCHAIN(Mandatory)

SET
GCELLCHMGBASIC(Optional)

SET BTSAPMUBP(Optional)
SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET GCELLCCCH(Optional)

SET
GCELLBASICPARA(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLBASICPARA(Optional)

ADD GCELLMAGRP(Optional)

ADD
BTSRXUCHAIN(Mandatory)

ADD GCELL(Optional)

ADD
BTSRXUCHAIN(Mandatory)
ADD BTSBFD(Mandatory)

SET BTSDHEUBP(Optional)

SET BTSDHEUBP(Optional)

SET BTSAPMUBP(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSAIRCON(Optional)

SET SCCPTMR(Optional)
STR
TRANSPERFTST(Mandatory)
STR
TRANSPERFTST(Mandatory)
STR
TRANSPERFTST(Mandatory)
SET SCCPTMR(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

ADD G2GNCELL(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)
SET
GCELLCHMGAD(Optional)

SET OTHSOFTPARA(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)
SET
GCELLCHMGAD(Optional)
SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

ADD G2GNCELL(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET OTHSOFTPARA(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

ADD G2GNCELL(Optional)

SET
GCELLCHMGAD(Optional)
SET
GCELLCHMGAD(Optional)
SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)
SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLBASICPARA(Optional)

SET BTSAPMUBP(Optional)

ADD IPPATH(Optional)

SET
BSCPSTCDSCPMAP(Optional)
SET
BSCPSTCDSCPMAP(Optional)
SET
BSCPSTCDSCPMAP(Optional)
ADD SCHTSK(Mandatory)
SET SCHTSKSW(Optional)
ADD SUBTSK(Optional)
ADD SUBCMD(Optional)
STR SCHTSK(Optional)
ADD
BTSBRDCAP(Mandatory)
SET TCPARA(Optional)

SET E1T1LOP(Optional)

SET
GCELLCHMGBASIC(Optional)

GCELLHO2GBA2(Mandatory)
SET GCELLHOAD(Mandatory)
SET
GCELLHOBASIC(Mandatory)
SET
GCELLHOCTRL(Mandatory)
SET
GCELLHOEDBPARA(Mandato
ry)
SET
GCELLHOEMG(Mandatory)
SET
GCELLHOFAST(Mandatory)
SET
GCELLHOFDDBA2(Mandator
y)
SET
GCELLHOFITPEN(Mandatory)
SET
GCELLHOIUO(Mandatory)
SET
GCELLHOPTP(Mandatory)
SET
GCELLHOTDDBA2(Mandator
y)
SET
GCELLHOUTRANFDD(Mandat
ory)
SET
GCELLHOUTRANTDD(Mandat
ory)
SET GCELLPWR2(Mandatory)
SET GCELLPWR3(Mandatory)
ADD G2GNCELL(Mandatory)

GCELLPRACH(Mandatory)
SET
GCELLPRIVATEOPTPARA(Man
datory)
SET
GCELLPSBASE(Mandatory)
SET
GCELLPSCHM(Mandatory)
SET GCELLPSCS(Mandatory)
SET GCELLPSI1(Mandatory)
SET
GCELLPSOTHERPARA(Manda
tory)
SET
GCELLPSPWPARA(Mandatory
)
SET
PSCELLTODSP(Mandatory)
SET
GCELLNC2PARA(Mandatory)
SET
GCELLNCRESELECTPARA(Ma
ndatory)
SET
GCELLNWCTRLMSRPARA(Ma
ndatory)
SET
GCELLRESELECTPARA(Mand
atory)
SET
GCELLSERVPARA(Mandatory)
SET
SET
GCELLHOINTERRATLDB(Man
datory)
ADD BTSESN(Mandatory)
SET
BSCABISPRIMAP(Mandatory)

SET
BTSEXCURSION(Mandatory)
ADD EXTNCELL(Mandatory)
SET
BSCSYNCOFF(Mandatory)
SET BTSAISS(Mandatory)

SET BTSLAPDWS(Mandatory)
SET
BTSPOWERTYPE(Mandatory)
SET BTSRXUBP(Mandatory)
SPT
BTSRXUCHAIN(Mandatory)
SET
BTSAUTODLDACTINFO(Mand
atory)
SET
BTSOTHPARA(Mandatory)
SET
BTSAUTOPLANCFG(Mandato
ry)
ADD
BTSLOCGRP(Mandatory)
ADD
BTSRXU2LOCGRP(Mandatory
)
ADD
BTSBINDLOCGRP(Mandatory
)
ADD
BTSANTFEEDERBRD(Mandat
ory)
ADD BTSBRD(Mandatory)
ADD
BTSCABINET(Mandatory)
ADD
BTSRXUBRD(Mandatory)
ADD
BTSTRXBRD(Mandatory)

SET
BTSOMLDETECT(Mandatory)
SET
BTSFLEXABISPARA(Mandator
y)
ADD
BTSTOPCONFIG(Mandatory)
LOD BTSSW(Mandatory)
LOD RETANTCFG(Mandatory)
SAV
BTSCLKPARA(Mandatory)
SET BTSRACKBC(Mandatory)
SET
BTSCLKPARA(Mandatory)
SET BTSCAVFRQ(Mandatory)
SET BTSPMUDEF(Mandatory)
SET BTSTMA(Mandatory)
SET RETANTENB(Mandatory)
STR
BTSBATTTST(Mandatory)
STR BTSLOG(Mandatory)
STR
BTSRACKTEMPMON(Mandato
ry)
STR BTSTST(Mandatory)
STR
RETANTSCAN(Mandatory)
STR
TRANSPERFTST(Mandatory)
SWP BTSBRD(Mandatory)
SWP
BTSCLKCLTPT(Mandatory)
ADD SEMILINK(Mandatory)
SET MSTOCELL(Mandatory)
TST SNDRSI(Mandatory)
TST UPDMSRAC(Mandatory)

SET
PSCELLTODSP(Mandatory)

ADD GCBSADDR(Optional)

ADD BTSIPRT(Mandatory)
IMP BTSIPRT(Mandatory)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)
STR BTSLOG(Optional)
ULD BTSLOG(Optional)

SET GCELLHOFAST(Optional)

CHK INNSPCH(Mandatory)
STR
CALLRESLOP(Mandatory)
ADD
GCSCHRUSER(Mandatory)

SET GCELLTMR(Optional)
SET
GCELLBASICPARA(Optional)

SET
GCELLPSOTHERPARA(Option
al)

SET
GCELLBASICPARA(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

ADD AISSCFG(Optional)

SET GCELLTMR(Optional)

SET MSTOCELL(Mandatory)
TST SNDRSI(Mandatory)
TST UPDMSRAC(Mandatory)
ADD
GPSCHRUSER(Mandatory)

CHK INNSPCH(Mandatory)
STR
CALLRESLOP(Mandatory)
ADD
GCSCHRUSER(Mandatory)

SET GCELLTMR(Optional)

ADD AISSCFG(Optional)

ADD AISSCFG(Optional)

SET GCELLLCS(Optional)

ADD BTSCONNECT(Optional)

SET BTSDOMUBP(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

ADD GNRNC(Mandatory)

ADD EMU(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET GTRXDEV(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

ADD SEMILINK(Optional)

SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)
ADD EXTNCELL(Mandatory)

ADD EXTNCELL(Mandatory)
SET
GCELLHOEDBPARA(Optional)
SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)
ADD
BTSCONNECT(Mandatory)
ADD SEMILINK(Mandatory)
ADD
DXXTSEXGRELATION(Mandat
ory)
SET GCELLLCS(Optional)

SET GCELLHOCTRL(Optional)

ADD BTSCONNECT(Optional)
ADD SEMILINK(Mandatory)
ADD BTSCONNECT(Optional)
ADD SEMILINK(Mandatory)
ADD GSMSCB(Mandatory)

ADD G2GNCELL(Optional)

SET GCELLSOFT(Optional)

ADD G2GNCELL(Optional)

SET
GCELLHOFITPEN(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLCHMGAD(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

ADD AISSCFG(Optional)

SET GCELLOTHEXT(Optional)

SET
GCELLHOBASIC(Optional)
SET
GCELLHOINTERRATLDB(Opti
onal)
SET
GCELLHOBASIC(Optional)
SET
GCELLHOBASIC(Optional)
SET
GCELLHOINTERRATLDB(Opti
onal)

SET
GCELLHOINTERRATLDB(Opti
onal)

SET
GCELLHOINTERRATLDB(Opti
onal)

SET
GCELLHOINTERRATLDB(Opti
onal)

SET
GCELLHOINTERRATLDB(Opti
onal)
SET
GCELLHOINTERRATLDB(Opti
onal)
SET
GCELLHOBASIC(Optional)

SET
GCELLHOINTERRATLDB(Opti
onal)

STR
ETHOAMLOOPTST(Optional)

EXP LOG(Optional)
SET
GCELLEXTMSRPARA(Optional
)

SET
GCELLHOEDBPARA(Optional)

SET GCELLTMR(Optional)

SET GCELLTMR(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET GCELLTMR(Optional)

ADD GNRNC(Mandatory)

SET
GCELLHOINTERRATLDB(Opti
onal)

SET
GCELLHOINTERRATLDB(Opti
onal)

SET
GCELLHOINTERRATLDB(Opti
onal)
ADD SEMILINK(Mandatory)
ADD
DXXTSEXGRELATION(Mandat
ory)
ADD SUBTSK(Optional)

SET ASWPARA(Mandatory)
SET
GCELLCCUTRANSYS(Optiona
l)
SET BTSETHPORT(Optional)
IMP BTSDEVIP(Optional)
ADD XPUVLAN(Mandatory)
ADD NSVLLOCAL(Mandatory)

ADD
NSVLREMOTE(Mandatory)

EXP LOG(Optional)
ADD
SNTPSRVINFO(Mandatory)
DLD LICENSE(Mandatory)
ULD LICENSE(Mandatory)

DLD RETANTCFG(Mandatory)
ULD
BTSDEVFILE(Mandatory)
DLD BTSPATCH(Mandatory)
ULD BTSLOG(Mandatory)
DLD BTSSW(Mandatory)

ADD DEVIP(Mandatory)
ADD
SGSNROUTEINFO(Mandatory
)

ADD IPPATH(Mandatory)

ADD ETHIP(Mandatory)
ADD
ICMPGUARD(Mandatory)

ADD VLANID(Mandatory)
ADD ETHTRKIP(Mandatory)
SET
BTSIPCLKPARA(Mandatory)
ADD SGSN(Mandatory)
SET
BTSIPCLKPARA(Mandatory)
ADD SGSN(Optional)

ADD SGSN(Optional)

ADD SGSN(Optional)

SET BTSETHPORT(Optional)
ADD BTSPPPLNK(Optional)
ADD BTSMPGRP(Optional)
IMP BTSPPPLNK(Optional)
IMP BTSMPGRP(Optional)

SET BTSETHPORT(Optional)
ADD BTSPPPLNK(Optional)
ADD BTSMPGRP(Optional)
IMP BTSPPPLNK(Optional)
IMP BTSMPGRP(Optional)

ADD PPPLNK(Optional)

ADD MPGRP(Optional)
ADD ETHIP(Mandatory)
ADD ETHTRKIP(Mandatory)
ADD IPMUX(Optional)

ADD BTS(Optional)
ADD
BTSAUTOPLAN(Optional)
IMP BTSIPPARA(Mandatory)

SET BTSDHEUBP(Optional)

ADD AISSCFG(Mandatory)

ADD G2GNCELL(Optional)

SET
BTSIPCLKPARA(Mandatory)

SET
BTSIPCLKPARA(Mandatory)

ADD BTS(Optional)

ADD BTSRXUBRD(Optional)

ADD GEXT2GCELL(Optional)
ADD RSCGRP(Mandatory)
ADD GEXT2GCELL(Optional)

ADD GTRX(Optional)

SET BSCBASIC(Mandatory)
ADD
BTSLOCGRP(Mandatory)
ADD GEXT2GCELL(Optional)

ADD NSE(Optional)

ADD IPMUX(Mandatory)

ADD AISSCFG(Mandatory)

SET BTSENVALM(Mandatory)

SET BTSOTHPARA(Optional)

SET BTSLSW(Optional)

SET BSCBASIC(Optional)

ADD BRD(Mandatory)

ADD SUBRACK(Optional)

SET BTSDHEUBP(Optional)

SET BTSPSUFP(Optional)

SET
GCELLIDLEFDDBA1(Mandato
ry)
SET
GCELLIDLETDDBA1(Mandato
ry)
SET
GCELL2GBA1(Mandatory)
SET
GCELLHO2GBA2(Mandatory)
SET
GCELLHOFDDBA2(Mandator
y)
SET
GCELLHOTDDBA2(Mandator
y)

SET GCELLREV(Mandatory)

SET
GCELLIDLEFDDBA1(Mandato
ry)
SET
GCELLIDLETDDBA1(Mandato
ry)
SET
GCELL2GBA1(Mandatory)
SET
GCELLHO2GBA2(Mandatory)
SET
GCELLHOFDDBA2(Mandator
y)
SET
GCELLHOTDDBA2(Mandator
y)

SET GCELLREV(Mandatory)

ADD IPPATH(Mandatory)
ADD ADJMAP(Mandatory)
ADD TRMMAP(Mandatory)

ADD BTSIPRT(Mandatory)
IMP BTSIPRT(Mandatory)

SET GTRXIUO(Mandatory)

SET GCELLPSCHM(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

ADD GCELL(Optional)

SET OPT(Optional)

SET OPT(Mandatory)

SET OPT(Optional)

SET OPT(Optional)

SET OPT(Optional)

SET OPT(Optional)

SET OPT(Mandatory)

SET OPT(Optional)

SET OPT(Optional)

SET OPT(Optional)

SET COPTLNK(Optional)

SET COPTLNK(Optional)

SET COPTLNK(Optional)

SET COPTLNK(Optional)

SET COPTLNK(Optional)

SET OPT(Optional)
SET COPTLNK(Optional)

SET BTSJBF(Mandatory)

SET BTSOTHPARA(Optional)

SET OTHSOFTPARA(Optional)

SET MSP(Optional)

SET GCELLHOAD(Optional)

ADD PPPLNK(Optional)
ADD MPLNK(Optional)

ADD GCELL(Mandatory)
ADD
GEXT2GCELL(Mandatory)
ADD
GEXT3GCELL(Mandatory)
SET FHO(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)
SET
BTSAUTOPLANCFG(Optional)
ADD
GCELLQUICKSETUP(Mandato
ry)

SET
BTSAUTOPLANCFG(Optional)

ADD ETHTRK(Mandatory)

SET GCELLLCS(Mandatory)

SET GCELLLCS(Mandatory)

SET GCELLLCS(Mandatory)

SET GCELLLCS(Mandatory)

SET GCELLLCS(Mandatory)

SET GCELLLCS(Mandatory)
ADD GPS(Mandatory)
ADD GPS(Mandatory)

ADD IPLOGICPORT(Optional)

ADD IPLOGICPORT(Optional)

ADD IPLOGICPORT(Optional)

ADD IPLOGICPORT(Optional)

ADD IPLOGICPORT(Optional)
SET
GCELLBASICPARA(Optional)

ADD GEXT2GCELL(Optional)

SET GCELLHOAD(Optional)

ADD GEXTSMLC(Optional)

ADD GEXTSMLC(Optional)

SET LDR(Optional)

SET LDR(Optional)

SET LDR(Optional)
ADD M3LE(Mandatory)
ADD M3DE(Mandatory)
ADD ETHMD(Optional)
SET ALMML(Mandatory)

COL LOG(Optional)

EXP LOG(Optional)

SET
GCELLBASICPARA(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

ADD G2GNCELL(Optional)

ADD G2GNCELL(Optional)

ADD PPPLNK(Mandatory)
ADD MPGRP(Mandatory)

ADD BRD(Optional)

CON PATCH(Optional)
LOD PATCH(Optional)
LOD BRD(Optional)

ADD BRD(Optional)
ADD PBSL(Optional)

SET BTSEXD(Optional)

SET LICALMTHD(Mandatory)

SET LICALMTHD(Mandatory)
LOP LAPDLNK(Mandatory)

EXP
GCELLTEMPLATE(Optional)

ADD MTP3LNK(Optional)
SET
BTSENVALMPORT(Optional)
SET ALMPORT(Optional)

SET E1T1LOP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET OPT(Optional)
ADD SEMILINK(Optional)

ADD M3LNK(Optional)

ADD MTP3LKS(Optional)

ADD M3LKS(Optional)

ADD GEXT2GCELL(Optional)
ADD GEXT3GCELL(Optional)
SET GCELLHOAD(Optional)

ADD
GCNOPERATOR(Optional)

SET
BSCPSSOFTPARA(Optional)

SET BTSPMUBP(Optional)

SET GCELLHOAD(Optional)

SET
GCELLHOBASIC(Optional)

ADD GEXT2GCELL(Optional)

ADD GEXT3GCELL(Optional)

ADD G2GNCELL(Optional)

SET
GCELLHOFITPEN(Optional)

SET
GCELLHOFITPEN(Optional)

SET GCELLHOAD(Optional)

SET GCELLHOAD(Optional)

SET GCELLHOAD(Optional)

SET GCELLHOAD(Optional)

SET BTSDPMUBP(Optional)

SET
GCELLNC2PARA(Optional)
SET
GCELLNC2PARA(Optional)

SET
GCELLNC2PARA(Optional)

SET
GCELLNC2PARA(Optional)
SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)
SET
BSCABISPRIMAP(Optional)
SET
GBSCREDGRP(Mandatory)
ADD BTSPPPLNK(Mandatory)
IMP BTSPPPLNK(Mandatory)

ADD BTSMPGRP(Mandatory)
IMP BTSMPGRP(Mandatory)
ADD PPPLNK(Mandatory)
ADD MPGRP(Mandatory)
ADD NSVLLOCAL(Mandatory)
ADD
SGSNROUTEINFO(Mandatory
)
ADD
BTSLOCGRP(Mandatory)
ADD
BTSRXU2LOCGRP(Mandatory
)
SWP
BTSLOCGRP(Mandatory)
ADD
BTSOBJALMSHLD(Mandatory
)

EXP ALMLOG(Optional)
STA ALMLOG(Optional)

ADD SCTPLNK(Mandatory)

ADD SCTPLNK(Optional)

SET OPLOCK(Mandatory)

ADD SCTPLNK(Mandatory)

SET LODCTRL(Mandatory)
LOD BTSSW(Optional)
LOD BTSPATCH(Optional)
SET FCCPUTHD(Optional)

SET FCMSGQTHD(Optional)

ADD SCTPLNK(Mandatory)

ADD SCTPLNK(Mandatory)

ADD SCTPLNK(Mandatory)

SET FCCPUTHD(Optional)

SET FCMSGQTHD(Optional)

SET FCSW(Optional)

COL LOG(Mandatory)

STR BTSLOG(Mandatory)
ULD BTSLOG(Mandatory)
SET GCELLLCS(Mandatory)

SET GCELLLCS(Mandatory)

SET GCELLLCS(Mandatory)

SET GCELLLCS(Mandatory)

SET GCELLLCS(Mandatory)

SET GCELLLCS(Mandatory)
ADD GPS(Mandatory)
ADD GPS(Mandatory)
STR BTSTST(Optional)

STR
FRPORTLOOP(Mandatory)

SET E1T1(Optional)

LOP LAPDLNK(Mandatory)
SET
GCELLCHMGAD(Optional)
STR
CALLRESLOP(Mandatory)

STR
CALLRESLOP(Mandatory)

SET E1T1LOP(Mandatory)

SET OPTLOP(Mandatory)

STR CALLRESLOP(Optional)

ADD IPLOGICPORT(Optional)

SET GCELLSOFT(Optional)

SET
BTSFLEXABISPARA(Optional)
SET
GCELLOTHBASIC(Optional)

SET
GCELLCHMGAD(Optional)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

STR
TRANSPERFTST(Mandatory)

ADD IPPATH(Mandatory)

ADD IPLOGICPORT(Optional)

SET BTSIP(Mandatory)

ADD IPPATH(Mandatory)

ADD
IPLOGICPORT(Mandatory)

SET
GCELLEGPRSPARA(Optional)

SET BTSAPMUBP(Optional)

SET BTSAPMUBP(Optional)

SET LDR(Optional)

EXP LOG(Optional)

CMP TBLDATA(Optional)

EXP
EXP
EXP
EXP
EXP
EXP
EXP

BTSIPPARA(Optional)
BTSVLAN(Optional)
BTSDEVIP(Optional)
BTSPPPLNK(Optional)
BTSMPGRP(Optional)
BTSMPLNK(Optional)
BTSIPRT(Optional)

LOD BRD(Optional)

SET LOGLIMIT(Mandatory)

EXP LOG(Mandatory)

SET BTSDHEUBP(Optional)

SET BTSEXD(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET
DSPLVDSMODE(Mandatory)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSAPMUBP(Optional)

SET SCTPSRVPORT(Optional)

ADD XPUVLAN(Mandatory)

SET BTSETHPORT(Optional)

SET BTSETHPORT(Optional)

SET GCELLSOFT(Optional)

ADD ETHMA(Mandatory)
ADD ETHMEP(Mandatory)
PING MAC(Mandatory)
TRC MAC(Mandatory)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

ADD
BTSAUTOPLAN(Mandatory)

ADD BTSESN(Mandatory)
ADD
BTSBINDLOCGRP(Mandatory
)
ADD BTS(Optional)
SET
BTSAUTODLDACTINFO(Mand
atory)
SET
GCELLMAIOPLAN(Optional)
SET
GCELLMAIOPLAN(Optional)
SET
GCELLMAIOPLAN(Optional)
SET
GCELLMAIOPLAN(Optional)
SET
GCELLMAIOPLAN(Optional)

SET
GCELLMAIOPLAN(Optional)
SET
GCELLMAIOPLAN(Optional)
SET
GCELLMAIOPLAN(Optional)
SET
GCELLMAIOPLAN(Optional)
SET
GCELLMAIOPLAN(Optional)
SET
GCELLMAIOPLAN(Optional)
SET
GCELLMAIOPLAN(Optional)
SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

ADD BTSETHMA(Mandatory)
ADD
BTSETHLCMEP(Mandatory)
ADD
BTSETHRMMEP(Mandatory)

ADD ETHMA(Mandatory)
PING BTSCFM(Mandatory)
TRC BTSCFM(Mandatory)

ADD BTSPPPLNK(Mandatory)
IMP BTSPPPLNK(Mandatory)

ADD BTSMPGRP(Mandatory)
IMP BTSMPGRP(Mandatory)

ADD MPGRP(Mandatory)
SET BTSETHPORT(Optional)
IMP BTSDEVIP(Optional)
ADD ETHIP(Mandatory)
ADD EMSIP(Mandatory)
ADD PPPLNK(Mandatory)
ADD
ICMPGUARD(Mandatory)
ADD IPRTBIND(Mandatory)
ADD ETHTRKIP(Mandatory)

ADD GCBSADDR(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)
SET
BTSIPCLKPARA(Mandatory)

SET GCELLPWR2(Optional)

ADD SCTPLNK(Optional)

ADD IPLOGICPORT(Optional)

SET GCELLHOAD(Optional)

SET
BSCPSSOFTPARA(Optional)
SET
BSCPSSOFTPARA(Optional)
SET BTSBAKPWR(Optional)

ADD
BTSAUTOPLAN(Mandatory)
SET
BTSAUTOPLANCFG(Optional)

SET
BTSAUTOPLANCFG(Optional)

ADD IPMUX(Optional)

SET OTHSOFTPARA(Optional)

ADD MPGRP(Optional)

ADD PPPLNK(Optional)

SET PWDPOLICY(Optional)

SET ALMCAPACITY(Optional)

SET BTSDPMUBP(Optional)

ADD SCTPLNK(Optional)

SET OTHSOFTPARA(Optional)

SET GTRXBASE(Optional)

SET GCELLPSCHM(Optional)

SET
BSCPSSOFTPARA(Optional)
SET PWDPOLICY(Optional)

SET BTSPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET GCELLHOAD(Optional)

SET GCELLPRACH(Optional)

SET GCELLPRACH(Optional)

SET GCELLPRACH(Optional)

SET GCELLPRACH(Optional)

ADD PPPLNK(Optional)

ADD MPGRP(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET
GCELLBASICPARA(Optional)

SET GCELLCCAD(Optional)

SET GCELLCCAD(Optional)

SET GCELLCCAD(Optional)

STR POSAVE(Optional)

SET GTRXBASE(Optional)
TRC IPADDR(Optional)

SET GCELLPWR2(Optional)

SET PWDPOLICY(Optional)
ADD IPRTBIND(Mandatory)
STR IPCHK(Mandatory)

SET
GCELLCCBASIC(Optional)

SET
GCELLHOFITPEN(Optional)

SET
GCELLHOFITPEN(Optional)

COL SYNCINFO(Mandatory)

COL SYNCINFO(Mandatory)

ADD
GCNOPERATOR(Mandatory)
ADD GCELL(Mandatory)
ADD
GEXT2GCELL(Mandatory)
ADD
GEXT3GCELL(Mandatory)
SET FHO(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)
SET
BTSAUTOPLANCFG(Optional)
ADD
GCELLQUICKSETUP(Mandato
ry)

SET
BTSAUTOPLANCFG(Optional)
ADD BTSMPGRP(Optional)
IMP BTSMPGRP(Optional)

ADD MPGRP(Optional)
ADD NCELL(Mandatory)
COL SYNCINFO(Mandatory)
ADD NCELL(Mandatory)
COL SYNCINFO(Mandatory)

SET
SET
SET
SET
SET

BTSFMUABP(Optional)
BTSAPMUBP(Optional)
BTSDATUBP(Optional)
BTSDEMUBP(Optional)
BTSDHEUBP(Optional)

SET
GCELLCHMGAD(Optional)
SET BTSPSUFP(Optional)
ADD ETHMD(Mandatory)
ADD ETHMA(Mandatory)
ADD BTSETHMD(Optional)
ADD ETHMD(Mandatory)
PING BTSCFM(Mandatory)
TRC BTSCFM(Mandatory)

ADD BTSETHMD(Mandatory)
ADD BTSETHMA(Mandatory)
ADD
BTSETHLCMEP(Mandatory)
ADD
BTSETHRMMEP(Mandatory)

SET GCELLPSI1(Optional)

ADD GNRNC(Mandatory)

SET
GCELLCCUTRANSYS(Optiona
l)

ADD ETHMEP(Mandatory)

ADD
BTSETHLCMEP(Mandatory)
ADD
BTSETHRMMEP(Mandatory)

ADD ETHMEP(Mandatory)

ADD BTSMPGRP(Optional)
IMP BTSMPGRP(Optional)

ADD MPGRP(Optional)

SET
GCELLNC2PARA(Optional)

ADD IPLOGICPORT(Optional)

ADD GEXT3GCELL(Optional)

ADD G2GNCELL(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET GCELLHOCTRL(Optional)

SET
GCELLCHMGBASIC(Optional)

ADD GEXT3GCELL(Optional)

STR IPCHK(Optional)
ADD BTSBFD(Optional)

STR IPCHK(Optional)

ADD BTSBFD(Optional)
STR
ETHMIRRORPORT(Mandatory
)
STR
ETHMIRRORPORT(Mandatory
)
STR
ETHMIRRORPORT(Mandatory
)

ADD
GCNOPERATOR(Mandatory)
ADD GCELL(Mandatory)
ADD
GEXT2GCELL(Mandatory)
ADD
GEXT3GCELL(Mandatory)
SET FHO(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)
SET
BTSAUTOPLANCFG(Optional)
ADD
GCELLQUICKSETUP(Mandato
ry)

SET
BTSAUTOPLANCFG(Optional)
SET BSCFCPARA(Optional)

ADD SCTPLNK(Mandatory)

STR IPCHK(Optional)

SET CLKMODE(Mandatory)

SET QUICKCFG(Mandatory)
SWP
MBSCMODE(Mandatory)
CHK MODEDATA(Mandatory)
SET GCSFILE(Mandatory)

SET MSP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

SET BTSDATUBP(Optional)

STR
BTSRACKTEMPMON(Mandato
ry)
STR
BTSRACKTEMPMON(Mandato
ry)
SET
BTSAUTODLDACTINFO(Mand
atory)
SET GCELLHOFAST(Optional)

ADD BTSMPGRP(Optional)
IMP BTSMPGRP(Optional)

ADD BTSMPGRP(Optional)
IMP BTSMPGRP(Optional)

ADD BTSMPGRP(Mandatory)
ADD BTSMPLNK(Mandatory)
IMP BTSMPGRP(Mandatory)
IMP BTSMPLNK(Mandatory)

ADD MPGRP(Mandatory)
ADD MPLNK(Mandatory)
ADD IPLOGICPORT(Optional)

ADD BTS(Optional)

SET
SET
SET
SET
SET

BTSFMUABP(Optional)
BTSAPMUBP(Optional)
BTSDATUBP(Optional)
BTSDEMUBP(Optional)
BTSDHEUBP(Optional)

ADD BTSMPGRP(Optional)
IMP BTSMPGRP(Optional)

ADD MPGRP(Optional)
SET MPUBIND(Mandatory)
ADD BRD(Mandatory)
SET MPUBIND(Mandatory)
ADD BRD(Mandatory)

SET GCELLPWR2(Optional)

SET
GCELLHOFITPEN(Optional)

SET GCELLPWR3(Optional)

SET GCELLHOCTRL(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET GMRSCOPE(Mandatory)

SET GMRCTRL(Mandatory)

ADD BTSPPPLNK(Optional)
ADD BTSMPLNK(Optional)
IMP BTSPPPLNK(Optional)
IMP BTSMPLNK(Optional)

ADD AISSCFG(Optional)

SET GCELLSOFT(Optional)

ADD GCNNODE(Optional)
ADD
GCNOPERATOR(Mandatory)
ADD
GCNOPERATOR(Optional)

ADD
GCNOPERATOR(Optional)

ADD GCNNODE(Optional)
SET
GCELLCCUTRANSYS(Optiona
l)

SET GCELLTMR(Optional)

CHK INNSPCH(Mandatory)
STR
CALLRESLOP(Mandatory)
ADD
GCSCHRUSER(Mandatory)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET BSSLS(Optional)

SET GCELLHOFAST(Optional)

SET
GCELLCCBASIC(Optional)

SET MSPCMD(Mandatory)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET
SET
SET
SET
SET

BTSFMUABP(Optional)
BTSAPMUBP(Optional)
BTSDATUBP(Optional)
BTSDEMUBP(Optional)
BTSDHEUBP(Optional)

ADD GEXT2GCELL(Optional)

SET
GCELLNC2PARA(Optional)

SET BSSGPPARA(Optional)

SET GBSCREDGRP(Optional)

SET
GCELLSERVPARA(Optional)
SET SLFSLVSW(Optional)

SET BSCFCPARA(Optional)
CHK E1T1CRS(Mandatory)
ADD MTP3LNK(Mandatory)
ADD GPS(Optional)

ADD SCTPLNK(Optional)

SET BTSETHPORT(Optional)

SET ETHPORT(Optional)

SET BTSBAT(Optional)

SET
GCELLSERVPARA(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

ADD PPPLNK(Optional)

ADD MPGRP(Optional)

ADD IPMUX(Mandatory)

SET BTSCABPARA(Optional)
STR IPCHK(Optional)

SET BTSRINGATTR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET
GCELLSTANDARDOPTPARA(O
ptional)

SET
GCELLSTANDARDOPTPARA(O
ptional)

SET
GCELLSTANDARDOPTPARA(O
ptional)

ADD BC(Optional)

ADD BC(Optional)

ADD BC(Optional)

SET GCELLGPRS(Optional)

ADD OPC(Mandatory)

ADD N7DPC(Mandatory)

ADD MTP3RT(Mandatory)

ADD MTP3LKS(Mandatory)

ADD MTP3LNK(Mandatory)

ADD M3LE(Mandatory)

ADD M3DE(Mandatory)

ADD M3RT(Mandatory)

ADD M3LKS(Mandatory)

ADD M3LNK(Mandatory)

ADD PCU(Mandatory)

ADD ADJNODE(Mandatory)
SET
GCELLCHMGAD(Optional)
SET
GCELLPSPWPARA(Optional)

SET
GCELLBASICPARA(Optional)

ADD
GIBCAPNCGRP(Mandatory)
ADD
GIBCAPNCGRP(Mandatory)
ADD
GIBCAPNCGRP(Mandatory)

ADD
GIBCAPNCGRP(Mandatory)
ADD G2GNCELL(Mandatory)

ADD G2GNCELL(Mandatory)

ADD G3GNCELL(Mandatory)

ADD G3GNCELL(Mandatory)
SET
BTSAUTOPLANCFG(Optional)
ADD G2GNCELL(Mandatory)

ADD G2GNCELL(Mandatory)

ADD G2GNCELL(Mandatory)

ADD G2GNCELL(Mandatory)

SET GCELLGPRS(Optional)

SET
BSCPSSOFTPARA(Optional)

SET GCELLGPRS(Optional)

ADD GCELL(Optional)
ADD
GEXT2GCELL(Mandatory)
ADD
GCELLQUICKSETUP(Optional
)

SET
GCELLIDLEBASIC(Optional)

SET
GCELLEXTMSRPARA(Optional
)

SET GCELLHOFAST(Optional)

SET
GCELLHOFITPEN(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET GCELLGSMR(Optional)

SET GCELLGSMR(Optional)

SET GCELLPSBASE(Optional)

ADD N7DPC(Optional)

ADD XPUVLAN(Mandatory)

SET GCELLHOCTRL(Optional)

ADD BTSIPRT(Mandatory)
ADD
BTSIPRTBIND(Mandatory)
IMP BTSIPRT(Mandatory)

ADD OMUIPRT(Mandatory)
ADD IPRT(Mandatory)
ADD IPRTBIND(Mandatory)
ADD OPC(Mandatory)

DLD TCFILE(Mandatory)

SET GCELLPSBASE(Optional)

SET
BTSALMPORT(Mandatory)
SET
BTSALMPORT(Mandatory)
SET
BTSALMPORT(Mandatory)
SET
BTSALMPORT(Mandatory)
SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET PWRPARA(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLHOBASIC(Optional)

ADD ADJNODE(Mandatory)

SET GCELLHOEMG(Optional)

SET GCELLHOEMG(Optional)

SET GCELLHOEMG(Optional)

SET BTSPMUBP(Optional)

SET GCELLPWR3(Optional)
SET
GCELLNWCTRLMSRPARA(Opt
ional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET
GCELLNC2PARA(Optional)

SET BTSCABPARA(Optional)

SET OTHSOFTPARA(Optional)

SET GTRXRLALM(Optional)

SET BTSFALLBACK(Optional)

TRC IPADDR(Optional)

SET
GCELLHOFITPEN(Optional)

SET
GCELLHOFITPEN(Optional)

ADD
NRIMSCMAP(Mandatory)
ADD
NRISGSNMAP(Mandatory)

SET OTHSOFTPARA(Optional)

ADD NSE(Mandatory)
ADD NSVC(Mandatory)
ADD
NSVLLOCAL(Mandatory)
ADD
NSVLREMOTE(Mandatory)
ADD PTPBVC(Mandatory)
BLK PTPBVC(Mandatory)
ADD
GCELLQUICKSETUP(Optional
)

SET
GCELLHOFITPEN(Optional)

SET GCELLLCS(Optional)
ADD NSVC(Mandatory)

ADD NSVC(Mandatory)
BLK NSVC(Mandatory)

SET BTSDHEUBP(Optional)

SET BTSDHEUBP(Optional)

SET GCELLGSMR(Optional)

SET ETHPORT(Optional)

ADD PPPLNK(Optional)

ADD MPGRP(Optional)

ADD IPLOGICPORT(Optional)
ADD ETHTRK(Optional)
SET QUEUEMAP(Mandatory)

SET QUEUEMAP(Optional)
STR
TRXBURSTTST(Mandatory)
SET
BTSANTANGLE(Mandatory)
ADD GPSCHRUSER(Optional)
ADD GCSCHRUSER(Optional)
ADD
OBJALMSHLD(Mandatory)
ADD
BTSOBJALMSHLD(Mandatory
)
SET FHO(Mandatory)

SET
GCELLPSOTHERPARA(Option
al)

SET GCELLHOIUO(Optional)

SET
BTSOMLBACKUP(Optional)

SET
BTSOMLDETECT(Mandatory)

SET OTHSOFTPARA(Optional)

SET
BSCABISPRIMAP(Optional)
SET BTSBWPARA(Mandatory)

SET BTSBWPARA(Mandatory)
SET
BSCABISPRIMAP(Optional)

SET BSCSRVPRI(Optional)

SET
BSCABISPRIMAP(Optional)
SET BTSLAPDWS(Optional)

ADD EMSIP(Optional)

ADD EMSIP(Optional)
EXP LOG(Optional)
ADD OP(Mandatory)
ULK USR(Mandatory)
ADD BTSOP(Mandatory)

ADD
GCELLOSPMAP(Mandatory)
ADD
GCELLQUICKSETUP(Mandato
ry)
BLK ACIC(Mandatory)
ADD AE1T1(Mandatory)
ADD
GCNOPERATOR(Mandatory)
ADD
GCNOPERATOR(Mandatory)
ADD GCBSADDR(Mandatory)

BLK ACIC(Mandatory)

BLK AE1T1(Mandatory)

BLK ATERE1T1(Mandatory)

UPD JTGCPLD(Mandatory)
BLK PBCIC(Mandatory)

ADD GCNNODE(Mandatory)
ADD
GCNOPERATOR(Mandatory)
ADD GCELL(Optional)
ADD GEXTSMLC(Mandatory)
ADD GEXT2GCELL(Optional)
ADD GEXT3GCELL(Optional)
ADD NSE(Mandatory)
ADD SGSNNODE(Mandatory)
ADD
NRISGSNMAP(Mandatory)
ADD PCU(Mandatory)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET GTRXDEV(Optional)

SET OPT(Optional)

SWP BTSBRD(Mandatory)

SET
BTSFORBIDTS(Mandatory)
ADD GNRNC(Mandatory)

ADD
BTSTOPCONFIG(Mandatory)
CON PATCH(Optional)
LOD PATCH(Optional)
ADD
GCELLQUICKSETUP(Optional
)
SET BTSOTHPARA(Optional)

SET GCELLHOIUO(Optional)

SET
GCELLHOEDBPARA(Optional)

SET GCELLTMR(Optional)

SET GCELLTMR(Optional)

SET GCELLHOAD(Optional)

SET
GCELLHOEDBPARA(Optional)

SET GTRXDEV(Optional)

SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)

SET
GCELLHOEDBPARA(Optional)

ADD SEMILINK(Optional)

ADD SEMILINK(Mandatory)
ADD
DXXTSEXGRELATION(Mandat
ory)
ADD
DXXTSEXGRELATION(Mandat
ory)
SET BTSDTMUBP(Optional)

SET BTSDTMUBP(Optional)

SET BTSDTMUBP(Optional)

SET BTSDTMUBP(Optional)

ADD
BTSLOCGRP(Mandatory)

ADD
BTSLOCGRP(Mandatory)
ADD BTSLOCGRP(Optional)

SET
GCELLHOEDBPARA(Optional)

SET GCELLSOFT(Optional)
ADD
ABISLOADSHARE(Mandatory
)
ADD SEMILINK(Mandatory)
ADD SEMILINK(Mandatory)
SET
GCELLHOINTERRATLDB(Opti
onal)
SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

ADD GNRNC(Optional)
ADD SEMILINK(Mandatory)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET GCELLCCCH(Optional)

SET BTSCABPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BTSOTHPARA(Optional)

SET
GCELLPSOTHERPARA(Option
al)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET
GCELLCCBASIC(Optional)

SET GCELLPSBASE(Optional)

SET GCELLPSBASE(Optional)

SET GCELLPSBASE(Optional)

SET GTRXDEV(Optional)

SET
BTSAUTODLDACTINFO(Mand
atory)
SET
BTSAUTODLDACTINFO(Mand
atory)
ADD IPPATH(Optional)

ADD IPPATH(Mandatory)

ADD IPMUX(Mandatory)
ADD
IPPATHBIND(Mandatory)
SET
GCELLPWRBASIC(Optional)
SET
GCELLHOBASIC(Optional)

ADD IPPATH(Optional)

CON PATCH(Optional)
LOD PATCH(Optional)
SET
GCELLPSPWPARA(Optional)

SET
GCELLHOBASIC(Optional)

ADD G2GNCELL(Optional)

ADD G2GNCELL(Optional)

ADD G2GNCELL(Optional)

SET OTHSOFTPARA(Optional)

SET
GCELLPWRBASIC(Optional)
SET
GCELLPSPWPARA(Optional)
BLK PBCIC(Mandatory)

ADD PCU(Mandatory)
SET GCELLGPRS(Mandatory)
ADD PBE1T1(Mandatory)

SET
BTSFLEXABISPARA(Optional)

SET GCELLPSCHM(Optional)

SET GCELLSOFT(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

ADD M3LKS(Optional)

SET BTSIP(Mandatory)
SET
GBSCREDGRP(Mandatory)
SET BTSIP(Mandatory)

SET BTSIP(Mandatory)

SET BTSIP(Mandatory)

ADD BTSPPPLNK(Mandatory)
IMP BTSPPPLNK(Mandatory)

ADD BTSMPGRP(Mandatory)
IMP BTSMPGRP(Mandatory)
ADD PPPLNK(Mandatory)
ADD MPGRP(Mandatory)
STR IPCHK(Mandatory)

ADD SCTPLNK(Mandatory)

ADD SCTPLNK(Optional)

ADD IPPATH(Mandatory)

ADD IPPATH(Optional)

ADD SCTPLNK(Mandatory)

SET
BTSLOADCTRL(Mandatory)

SET GCELLHOCTRL(Optional)

SET
GCELLNC2PARA(Optional)

SET
GCELLNC2PARA(Optional)

SET
GCELLHOFITPEN(Optional)

STR NCS(Mandatory)

ADD IPPATH(Optional)

ADD BTSPPPLNK(Optional)
ADD BTSMPGRP(Optional)
IMP BTSPPPLNK(Optional)
IMP BTSMPGRP(Optional)

ADD PPPLNK(Optional)

ADD MPGRP(Optional)

ADD NSE(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

ADD IPMUX(Mandatory)

SET PHBMAP(Mandatory)

SET
GCELLIDLEBASIC(Optional)

SET CERTFILE(Optional)

STR
ETHOAMLOOPTST(Optional)

STR
ETHOAMLOOPTST(Optional)

STR
FRPORTLOOP(Mandatory)

ADD
BTSABISMUXFLOW(Optional)

SET GCELLGPRS(Optional)

PING MAC(Optional)
PING BTSCFM(Optional)
PING IP(Optional)

SET GCELLPRACH(Optional)

SET GTRXDEV(Optional)

SET GCELLPRACH(Optional)

SET GCELLPRACH(Optional)

SET GTRXDEV(Optional)

SET GCELLPRACH(Optional)

SET GTRXDEV(Optional)

ADD IPLOGICPORT(Optional)

ADD IPLOGICPORT(Optional)

SET TCPLYVOICE(Mandatory)

SET TCPLYVOICE(Mandatory)

SET TCPLYVOICE(Optional)

SET FCCPUTHD(Optional)

SET FCMSGQTHD(Optional)

SET GCELLSOFT(Mandatory)

SET GCELLSOFT(Mandatory)

SET GCELLSOFT(Optional)

SET FCCPUTHD(Optional)

SET FCMSGQTHD(Optional)

SET FCSW(Optional)
ADD AE1T1(Mandatory)
BLK AE1T1(Mandatory)
ADD ATERE1T1(Mandatory)

SWP ETHPORT(Mandatory)

SET SCUPORT(Optional)

SET XPUPORT(Optional)

SET ALMPORT(Mandatory)
ADD
OBJALMSHLD(Mandatory)
SET
BTSENVALMPORT(Mandatory
)
ADD
BTSOBJALMSHLD(Mandatory
)
ADD BC(Mandatory)
STR IPCHK(Optional)
STR
ETHOAMLOOPTST(Mandator
y)

BLK ATERE1T1(Mandatory)

SET MSPCMD(Mandatory)
SET MSP(Mandatory)
SET E1T1LOP(Optional)
LOP E1T1(Optional)
SET E1T1(Optional)
STR E1T1TST(Optional)

SET OPTLOP(Mandatory)

SET OPT(Optional)
SET COPTLNK(Optional)

SET ETHPORT(Optional)
ADD
ETHREDPORT(Mandatory)
ADD ETHIP(Mandatory)
ADD ETHMEP(Mandatory)

ADD IPLOGICPORT(Optional)
STR FRPORTLOOP(Optional)
CHK E1T1CRS(Mandatory)

ADD PBE1T1(Mandatory)
ADD PBSL(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)

SET
BTSFORBIDTS(Mandatory)
ADD BTSPPPLNK(Mandatory)
ADD BTSMPLNK(Mandatory)
IMP BTSPPPLNK(Mandatory)
IMP BTSMPLNK(Mandatory)

SET BTSOMLTS(Mandatory)
ADD
BTSCONNECT(Mandatory)

SET
BTSETHPORT(Mandatory)
IMP BTSDEVIP(Mandatory)

ADD
BTSETHLCMEP(Mandatory)
STR BTSTST(Optional)

SET
GCELLPSOTHERPARA(Option
al)

SET
GCELLPSOTHERPARA(Option
al)

SET
GCELLPSOTHERPARA(Option
al)

SET
GCELLPSOTHERPARA(Option
al)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

ADD
ROLLBACKPOINT(Optional)

BEG ROLLBACK(Mandatory)
BEG FORWARD(Mandatory)
ADD
ROLLBACKPOINT(Mandatory)

ADD
FTPSCLTDPORT(Mandatory)
SWP BTSOMLLINK(Optional)

SWP BTSRING(Optional)
ADD
DXXCONNECT(Mandatory)
ADD DXX(Optional)
ADD
PORTFLOWCTRLPARA(Manda
tory)
SET XPUPORT(Mandatory)

ADD ETHMEP(Mandatory)

ADD
BTSTOPCONFIG(Mandatory)

SET
GCELLCCUTRANSYS(Optiona
l)

LOD BTSPATCH(Mandatory)
CON BTSPATCH(Mandatory)

SET BTSAPMUBP(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

SET BTSPMUBP(Optional)

SET
GCELLBASICPARA(Optional)

SET
GCELLBASICPARA(Optional)

SET BTSPMUBP(Optional)
SET
BTSPOWERTYPE(Optional)

SET GTRXDEV(Optional)

SET GTRXDEV(Optional)

ADD BTSPPPLNK(Optional)
IMP BTSPPPLNK(Optional)

ADD BTSPPPLNK(Optional)
IMP BTSPPPLNK(Optional)

ADD BTSPPPLNK(Mandatory)
ADD BTSMPLNK(Mandatory)
IMP BTSPPPLNK(Mandatory)
IMP BTSMPLNK(Mandatory)

ADD PPPLNK(Optional)
ADD MPLNK(Optional)

ADD IPLOGICPORT(Optional)

ADD PPPLNK(Optional)
ADD MPGRP(Optional)

ADD
PORTFLOWCTRLPARA(Option
al)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET GCELLCCAD(Optional)

SET GMRCTRL(Optional)
ADD BTSIPRT(Optional)
IMP BTSIPRT(Optional)

SET GCELLPSBASE(Optional)

SET BSCFCPARA(Optional)

SET GCELLHOCTRL(Optional)

SET FCCPUTHD(Optional)

SET FCMSGQTHD(Optional)

SET FCCPUTHD(Optional)

SET FCMSGQTHD(Optional)

SET FCSW(Optional)

SET
GCELLBASICPARA(Optional)

ADD GEXT2GCELL(Optional)

SET
BTSFLEXABISPARA(Optional)
SET
GCELLSERVPARA(Optional)
ADD MTP3RT(Optional)
ADD M3RT(Optional)
ADD MTP3LNK(Optional)
ADD M3LNK(Optional)

ADD IPRT(Mandatory)

SET
BTSOTHPARA(Mandatory)
SET
BTSOTHPARA(Mandatory)
SET
BTSOTHPARA(Mandatory)
SET CERTFILE(Optional)

SET BTSOTHPARA(Optional)

ADD N7DPC(Optional)

ADD BC(Optional)

SET BTSABISTROP(Optional)

SET
GCELLDYNTURNOFF(Optiona
l)

SET BSCDSTPA(Optional)

SET E1T1(Optional)
CHK E1T1CRS(Mandatory)
SET OPT(Optional)

SET COPTLNK(Mandatory)

SET GPSCHRCTRL(Optional)

SET GPSCHRCTRL(Optional)

SET GPSCHRCTRL(Optional)

SET GPSCHRCTRL(Optional)

SET GPSCHRCTRL(Optional)

ADD TRMFACTOR(Optional)

ADD TRMFACTOR(Optional)

ADD NSE(Optional)

ADD TRMMAP(Optional)

ADD TRMMAP(Optional)

ADD GCELL(Optional)

SET GCELLPSI1(Optional)

SET GCELLPSI1(Optional)

ADD TRMMAP(Optional)

ADD TRMMAP(Optional)

ADD GCELL(Optional)

SET GCELLHOIUO(Optional)

SET GPSCHRCTRL(Optional)

SET
GCELLCCACCESS(Optional)

ADD BTSLOCGRP(Optional)
SET
GPSCHRCTRL(Mandatory)
SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BTSAPMUBP(Optional)
SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)
SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET GCELLHOIUO(Optional)

SET BTSOTHPARA(Optional)

SET SLFSLVSW(Optional)

SET GCELLIDLEAD(Optional)

SET ALMPORT(Mandatory)
SET
BTSENVALMPORT(Optional)
ADD NSE(Mandatory)

ADD
SNTPSRVINFO(Mandatory)
SET E1T1(Optional)

SET E1T1(Optional)

SET E1T1(Optional)

SET E1T1(Optional)

ADD
BTSABISHDLCPATH(Mandato
ry)
ADD
BTSBIND2HDLCPATH(Mandat
ory)
ADD
GTRXBIND2HDLCPATH(Mand
atory)
SET ETHPORT(Mandatory)

SET BTSAPMUBP(Optional)

SET CERTFILE(Optional)

SET
BTSAUTODLDACTINFO(Optio
nal)

LOD BTSPATCH(Mandatory)
CON BTSPATCH(Mandatory)
SET
BSCPSSOFTPARA(Optional)
ADD OP(Mandatory)
DLD LICENSE(Mandatory)
ULD LICENSE(Mandatory)
DLD RETANTCFG(Mandatory)
ULD
BTSDEVFILE(Mandatory)
DLD BTSPATCH(Mandatory)
ULD BTSLOG(Mandatory)
DLD BTSSW(Mandatory)

SET CERTFILE(Mandatory)

SET PWDPOLICY(Optional)

STR BTSTST(Mandatory)

SET PWRALMSW(Optional)

SET PWRALMSW(Optional)

SET
GCELLPWRBASIC(Optional)

SET GCELLPWR3(Optional)

SET
GCELLPWRBASIC(Optional)
SET
GCELLCCACCESS(Optional)

SET
GCELLCCACCESS(Optional)

SET GCELLSOFT(Optional)

ADD
BTSBRDCAP(Mandatory)
ADD BTSRXUBRD(Optional)

SET BTSBAKPWR(Optional)

SET
GCELLCHMGAD(Optional)

SET GTRXDEV(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET QUEUEMAP(Optional)

SET QUEUEMAP(Optional)

SET QUEUEMAP(Optional)

SET QUEUEMAP(Optional)

SET QUEUEMAP(Optional)
SET
GCELLCCUTRANSYS(Optiona
l)
SET
GCELLHOBASIC(Optional)

SET GCELLHOAD(Optional)

SET GCELLHOAD(Optional)

SET GCELLHOAD(Optional)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLPSOTHERPARA(Option
al)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

SET GCELLSOFT(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET BTSAIRCON(Optional)

SET BTSAIRCON(Optional)

SET GCELLPWR2(Optional)

SET GCELLSOFT(Optional)
SET
GCELLHOBASIC(Optional)

SET BTSAUXEQP(Optional)

SET BTSBAT(Optional)

SET BTSBAT(Mandatory)

SET BTSBAT(Mandatory)

SET BTSBAT(Mandatory)

SET BTSAUXEQP(Optional)

SET BTSBAT(Optional)

SET BTSBAT(Mandatory)

SET BTSBAT(Mandatory)

SET BTSBAT(Mandatory)

SET BTSAUXEQP(Optional)

SET BTSBAT(Optional)

SET BTSBAT(Mandatory)

SET BTSBAT(Mandatory)

SET BTSBAT(Mandatory)
SET
BTSAUTOPLANCFG(Optional)
ADD
GCELLQUICKSETUP(Optional
)
ADD GEXT2GCELL(Optional)

ADD GEXT3GCELL(Optional)

SET GCELLGPRS(Optional)
SET
BTSAUTOPLANCFG(Optional)

SET
GCELLCCACCESS(Optional)

SET
GCELLCCBASIC(Optional)

SET GCELLCCCH(Optional)

ADD BTSLOCGRP(Optional)

SET GCELLPSBASE(Optional)
SET
GCELLRESELECTPARA(Optio
nal)

SET
GCELLCCACCESS(Optional)

SET
GCELLRESELECTPARA(Optio
nal)

SET BTSETHPORT(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GMRCTRL(Optional)

BEG FORWARD(Mandatory)

RUN BATCHFILE(Optional)

ADD
BTSRXUCHAIN(Mandatory)
SET
BTSBREAKPOINT(Mandatory)
SPT
BTSRXUCHAIN(Mandatory)

CBN
BTSRXUCHAIN(Mandatory)
CBN
BTSRXUCHAIN(Mandatory)

SET GTRXDEV(Optional)

ADD IPLOGICPORT(Optional)

SET
GCELLCCBASIC(Optional)

SET GCELLCCAD(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET OTHSOFTPARA(Optional)

ADD IPLOGICPORT(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

ADD BRD(Mandatory)

SET
BSCPSSOFTPARA(Optional)

SET
BSCPSSOFTPARA(Optional)

SET CLK(Optional)

SET CLK(Optional)

SET CLK(Optional)

SET CLK(Optional)

SET CLK(Optional)

SET CLK(Optional)

SET CLK(Optional)

SET BTSLSW(Optional)
SET
GREDGRPPRIMHOSTPOLICY(
Mandatory)

SET
GREDGRPPRIMHOSTPOLICY(
Mandatory)
SET
GREDGRPPRIMHOSTPOLICY(
Mandatory)
ADD AISSCFG(Mandatory)

SET BTSRXUBP(Mandatory)

SET BTSDFCUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Mandatory)

SET BTSRXUBP(Mandatory)

SET BTSDFCUBP(Optional)
ADD TRMMAP(Optional)
ADD
TRMFACTOR(Mandatory)
ADD IPRT(Mandatory)
ADD
NSVLREMOTE(Mandatory)

ADD GSMSCB(Mandatory)

SET
GCELLCCBASIC(Optional)

SET
GCELLCCBASIC(Optional)
SET
GCELLCCBASIC(Optional)
SET
BTSENVALMPORT(Optional)

SET OTHSOFTPARA(Optional)

SET
GCELLNC2PARA(Optional)

SET
GCELLNC2PARA(Optional)
SET
GCELLNC2PARA(Optional)

SET
GCELLNC2PARA(Optional)

SET GCELLPSCHM(Optional)

SET GCELLOTHEXT(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET PWDPOLICY(Optional)

SET BSCNSPARA(Optional)

SET BTSOTHPARA(Optional)

SET BSCNSPARA(Optional)

TST SNDRSI(Mandatory)

SET OTHSOFTPARA(Optional)

DLD LICENSE(Optional)
ULD LICENSE(Optional)
ADD PPPLNK(Optional)

ADD MPLNK(Optional)
EXP ALMLOG(Optional)
STA ALMLOG(Optional)

ADD GNRNC(Optional)

SET
GCELLCHMGBASIC(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLCCCH(Optional)

ADD SUBTSK(Optional)

ADD BTS(Optional)

SET BTSDGPSBP(Optional)

ADD NSE(Optional)

SET E1T1LOP(Optional)

SET
GCELLCCBASIC(Optional)

SET BSCBASIC(Optional)

ADD
GEXT3GCELL(Mandatory)

ADD GEXT3GCELL(Optional)
ADD GNRNC(Mandatory)
ADD
GIURGCONN(Mandatory)
ADD GNRNC(Mandatory)

SET CERTFILE(Optional)

ADD
SGSNROUTEINFO(Mandatory
)
ADD
SGSNROUTEINFO(Mandatory
)
SET GCELLSOFT(Optional)
SET
GCELLNWCTRLMSRPARA(Opt
ional)
SET
GCELLNWCTRLMSRPARA(Opt
ional)
ADD IPLOGICPORT(Optional)

SET
GCELLOTHBASIC(Optional)

SET
GCELLHOFITPEN(Optional)

SET
GCELLHOFITPEN(Optional)

ADD IPPATH(Mandatory)

ADD IPLOGICPORT(Optional)
ADD RSCGRP(Mandatory)

SET
GCELLHOFITPEN(Optional)

ADD G3GNCELL(Optional)

ADD GEXT3GCELL(Optional)

SET OPT(Optional)

SET OPT(Optional)

SET
GCELLNCRESELECTPARA(Opt
ional)

SET BTSBWPARA(Mandatory)
SET
BSCABISPRIMAP(Optional)
SET
BSCABISPRIMAP(Optional)

SET BTSBWPARA(Mandatory)
SET
BSCABISPRIMAP(Optional)
SET BTSLAPDWS(Optional)

LCK CMCTRL(Mandatory)

SET OTHSOFTPARA(Optional)

UPD JTGCPLD(Mandatory)

RUN BATCHFILE(Optional)

ADD OPC(Optional)

ADD BTSPPPLNK(Optional)
ADD BTSMPLNK(Optional)
IMP BTSPPPLNK(Optional)
IMP BTSMPLNK(Optional)

SET
GCELLCHMGBASIC(Optional)
SET
TRANSPATCHPARA(Optional)
SET
TRANSPATCHPARA(Optional)
SET
TRANSPATCHPARA(Optional)
SET
TRANSPATCHPARA(Optional)
SET
TRANSPATCHPARA(Optional)
SET
TRANSPATCHPARA(Optional)
SET
TRANSPATCHPARA(Optional)
SET
TRANSPATCHPARA(Optional)
SET
TRANSPATCHPARA(Optional)
SET
TRANSPATCHPARA(Optional)
SET BSCDSTPA(Optional)

SET MSP(Optional)

ADD M3LE(Optional)
ADD M3DE(Optional)

ADD GCNNODE(Optional)

ADD GCNNODE(Optional)

ADD OMUIPRT(Mandatory)

ADD OMUIPRT(Mandatory)
ADD BTSIPRT(Optional)
IMP BTSIPRT(Mandatory)

ADD SCTPLNK(Optional)

ADD SCTPLNK(Optional)

ADD SCTPLNK(Optional)

ADD SCTPLNK(Optional)

ADD SCTPLNK(Optional)
SET
GCELLBASICPARA(Optional)

SET GCELLPSCHM(Optional)

ADD BTSIPRT(Mandatory)
IMP BTSIPRT(Mandatory)

ADD IPLOGICPORT(Optional)

ADD IPLOGICPORT(Optional)

SET
BTSAUTODLDACTINFO(Mand
atory)
ADD IPPATH(Mandatory)

ADD RSCGRP(Mandatory)

SET
GCELLSERVPARA(Optional)
SET
GCELLAMRQUL(Optional)

SET
GCELLBASICPARA(Optional)

SET
GCELLHOBASIC(Optional)

SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
SET
GCELLAMRQUL(Optional)
ADD
TRXBIND2PHYBRD(Mandator
y)
SET BTSRXUBP(Mandatory)
ADD
BTSRXUBRD(Mandatory)

ADD
TRXBIND2PHYBRD(Mandator
y)
SET BTSRXUBP(Mandatory)
ADD
TRXBIND2PHYBRD(Mandator
y)
SET BTSRXUBP(Mandatory)
ADD
BTSRXUBRD(Mandatory)
ADD
TRXBIND2PHYBRD(Mandator
y)
SET BTSRXUBP(Mandatory)
ADD
BTSRXUBRD(Mandatory)
SET BTSRXUBP(Mandatory)

SET OPT(Optional)

SET OPT(Optional)

SET BTSDEMUBP(Optional)

SET BTSAPMUBP(Optional)

ADD GCNNODE(Optional)

SET
GCELLPWRBASIC(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR3(Optional)

SET BTSDPMUBP(Optional)

SET
GCELLDYNTURNOFF(Mandat
ory)
SET
GCELLDYNTURNOFF(Mandat
ory)

SET
GCELLDYNTURNOFF(Optiona
l)

SET
GCELLDYNTURNOFF(Optiona
l)
SET
GCELLDYNTURNOFF(Mandat
ory)

SET
GCELLCCBASIC(Optional)

SET BTSDPMUBP(Optional)

SET BTSDEMUBP(Optional)

SET BTSDEMUBP(Optional)

SET BTSDOMUBP(Optional)

SET BTSAPMUBP(Optional)

COL SYNCINFO(Mandatory)

COL SYNCINFO(Mandatory)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
BSCPSTCDSCPMAP(Optional)

SET GCELLHOFAST(Optional)

ADD NCELL(Mandatory)
COL SYNCINFO(Mandatory)
ADD NCELL(Mandatory)
COL SYNCINFO(Mandatory)

SET GCELLSBC(Optional)
ADD GSMSCB(Mandatory)

STR BTSTST(Optional)
ADD SUBTSK(Mandatory)
ADD SUBCMD(Mandatory)
SET GMRSCOPE(Mandatory)

ADD SRCONPATH(Optional)

ADD
GEXT3GCELL(Mandatory)
SET
GCELLHOFDDBA2(Mandator
y)

EXP ALMLOG(Optional)
STA ALMLOG(Optional)
ADD SCTPLNK(Mandatory)
ADD M3LNK(Mandatory)
EXP ALMLOG(Optional)

STA ALMLOG(Optional)

SET ALMCAPACITY(Optional)

ADD SUBTSK(Mandatory)

SET MSP(Optional)

STR BTSLOG(Optional)

SET TZ(Mandatory)

ADD
GCELLQUICKSETUP(Optional
)

SET GCELLHOAD(Optional)

SET GCELLHOAD(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET
GCELLBASICPARA(Optional)
SET MSP(Optional)

SET GCELLSOFT(Optional)

SET GTRXDEV(Optional)

SET GCELLHOCTRL(Optional)

SET GCELLPWR3(Optional)

ADD GEXT2GCELL(Optional)

ADD GEXT2GCELL(Optional)

SET
BSCPSTCDSCPMAP(Optional)
SET MSP(Optional)

SET BTSAPMUBP(Optional)

ADD
BTSALMMGMRULE(Mandator
y)
ADD
BTSALMMGMRULE(Mandator
y)

SET BTSAPMUBP(Optional)

SET
GCELLCCUTRANSYS(Optiona
l)
SET
BTSLOADCTRL(Mandatory)

SET OTHSOFTPARA(Optional)

SET
OTHSOFTPARA(Mandatory)

SET GCELLSOFT(Optional)

SET AITFOTHPARA(Optional)

SET OTHSOFTPARA(Optional)

SET GCELLGSMR(Optional)

SET GCELLGSMR(Optional)

SET BTSOTHPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SPT
BTSRXUCHAIN(Mandatory)

ADD BTS(Optional)

SET FTPSSRV(Mandatory)

SET FTPSSRV(Mandatory)

ADD BTSRETANT(Mandatory)
ADD
FTPSCLTDPORT(Mandatory)
SET BSCBASIC(Optional)

ADD BTS(Optional)

ADD
BTSAUTOPLAN(Mandatory)

EXP LOG(Optional)

SET BTSVLAN(Mandatory)
IMP BTSVLAN(Mandatory)

SET BTSAPMUBP(Optional)
SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)
SET BTSDPMUBP(Optional)

ADD
BTSSFPMODE(Mandatory)
ADD SGSNNODE(Optional)
ADD SGSN(Mandatory)
ADD
GCNOPERATOR(Mandatory)
ADD
GCNOPERATOR(Optional)

ADD
GCNOPERATOR(Optional)

SET GCELLPSBASE(Optional)

ADD SGSNNODE(Optional)

SET BSCFCPARA(Optional)
ADD
ABISLOADSHARE(Mandatory
)
SET BTSSHARING(Optional)

SET ALMSHLD(Mandatory)

SET BTSBAKPWR(Optional)

SET OTHSOFTPARA(Optional)

SET
GCELLHOBASIC(Optional)
ADD AISSCFG(Optional)

ADD MTP3RT(Mandatory)
ADD MTP3LKS(Mandatory)
ADD MTP3LNK(Mandatory)

ADD M3RT(Mandatory)
ADD M3LKS(Mandatory)
ADD M3LNK(Mandatory)
ADD M3LNK(Mandatory)

ADD NSVLLOCAL(Optional)

ADD NSVLREMOTE(Optional)

SET BSCSRVPRI(Optional)

ADD AISSCFG(Optional)

SET
GCELLHOFITPEN(Optional)
ADD MTP3LNK(Mandatory)
SET
GCELLHOFITPEN(Optional)
SET
BSCPSSOFTPARA(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

SET BSCBASIC(Optional)

PING IP(Mandatory)

TRC IPADDR(Optional)
COL LOG(Optional)

SET BTSAISS(Mandatory)
SET
BTSIPCLKPARA(Mandatory)
ADD
BTSBINDLOCGRP(Mandatory
)

STR
TRANSPERFTST(Mandatory)

ADD N7DPC(Optional)

SET GBSCREDGRP(Optional)

SET TZ(Mandatory)

ADD GEXTSMLC(Mandatory)

ADD GEXTSMLC(Mandatory)

ADD EMU(Optional)

SET TZ(Mandatory)

SET FCCPUTHD(Optional)
SET FCMSGQTHD(Optional)
ADD M3LNK(Mandatory)

SWP BRD(Mandatory)
STR BKP(Mandatory)
CMP BRDAREA(Optional)
ULD RSTINFO(Mandatory)
SET CLK(Mandatory)
UPD JTGCPLD(Mandatory)
SET XPUPORT(Mandatory)
ADD XPUVLAN(Mandatory)
SET MPUBIND(Mandatory)
SET
DPUBRDTYPE(Mandatory)
SET TCTYPE(Mandatory)
ADD BRD(Mandatory)
LOD BRD(Optional)
SYN BRDAREA(Optional)
CMP TBLDATA(Mandatory)
SET MSPCMD(Mandatory)
SET MSP(Mandatory)
SET
BFDPROTOSW(Mandatory)
STR
FRPORTLOOP(Mandatory)
ADD BC(Mandatory)
ADD NSVC(Mandatory)
ADD
NSVLLOCAL(Mandatory)
SET
PSCELLTODSP(Mandatory)
SET
DSPLVDSMODE(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)
DLD TCFILE(Mandatory)

ADD GCBSADDR(Mandatory)
SET TCPLYVOICE(Mandatory)
SET TCPARA(Mandatory)
ADD NSE(Mandatory)
EXP ALMLOG(Optional)
STA ALMLOG(Optional)
ADD OBJALMSHLD(Optional)

ADD BTSBFD(Optional)
ADD BTSIPRTBIND(Optional)
ADD
GIURGCONN(Mandatory)
ADD MTP3LNK(Optional)
ADD SCTPLNK(Mandatory)

SET PHBMAP(Mandatory)
ADD ATERE1T1(Mandatory)
ADD AE1T1(Mandatory)

BLK ATERE1T1(Mandatory)

SET QUEUEMAP(Mandatory)
SET E1T1(Mandatory)
ADD TSCROSS(Mandatory)
ADD DEVIP(Mandatory)
ADD IPRT(Mandatory)
SET OPT(Mandatory)
SET COPTLNK(Mandatory)
SET ETHPORT(Mandatory)
ADD PPPLNK(Mandatory)
ADD MPGRP(Mandatory)
ADD MPLNK(Mandatory)
ADD ETHIP(Mandatory)
ADD
IPLOGICPORT(Mandatory)
ADD
ICMPGUARD(Mandatory)
STR IPCHK(Mandatory)
ADD VLANID(Mandatory)
ADD
IPPATHBIND(Mandatory)
ADD IPRTBIND(Mandatory)
ADD ETHMD(Mandatory)
ADD ETHMA(Mandatory)
ADD ETHMEP(Mandatory)
PING MAC(Mandatory)
STR
ETHOAMLOOPTST(Mandator
y)
TRC MAC(Mandatory)
ADD ETHTRK(Mandatory)
ADD
ETHTRKLNK(Mandatory)
ADD ETHTRKIP(Mandatory)
SWP ETHPORT(Mandatory)
ADD
ETHREDPORT(Mandatory)
BLK AE1T1(Mandatory)
ADD PBE1T1(Mandatory)
ADD PBSL(Mandatory)

SET BTSDPMUBP(Mandatory)
SET BTSDTMUBP(Mandatory)
SET BTSDGPSBP(Mandatory)
SET BTSDDPUBP(Mandatory)
SET BTSUSCUBP(Mandatory)
SET BTSRXUBP(Mandatory)
ADD
BTSRXU2LOCGRP(Mandatory
)
ADD
BTSBINDLOCGRP(Mandatory
)
ADD
BTSANTFEEDERBRD(Mandat
ory)
ADD BTSBRD(Mandatory)
ADD BTSRXUBRD(Optional)
ADD
BTSTRXBRD(Mandatory)
SET
BTSENVALMPORT(Mandatory
)
SET
BTSANTFEEDERCONNECT(M
andatory)
ADD
BTSOBJALMSHLD(Mandatory
)
LOD RETANTCFG(Mandatory)
SET
BTSANTANGLE(Mandatory)
SET
BTSCLKPARA(Mandatory)

ADD BTSSFPMODE(Optional)
SET BTSFORBIDTS(Optional)
SET BTSOMLTS(Optional)
SET BTSETHPORT(Optional)
ADD BTSPPPLNK(Optional)
ADD BTSMPLNK(Optional)
ADD BTSETHMA(Optional)
ADD
BTSETHLCMEP(Optional)
ADD
BTSTOPCONFIG(Optional)
IMP BTSPPPLNK(Optional)
IMP BTSMPLNK(Optional)

ADD
BTSCONNECT(Mandatory)
OPR
BTSBRDPWR(Mandatory)

SET GTRXDEV(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)
SET
SNTPCLTPARA(Mandatory)

ADD OPC(Optional)

ADD OPC(Mandatory)

ADD OPC(Optional)
ADD PBE1T1(Mandatory)

ADD OPC(Optional)
ADD N7DPC(Optional)

SET
GCELLCCBASIC(Optional)

SET BTSFMUABP(Optional)

SET BTSFMUABP(Optional)

SET BSCBASIC(Optional)

SET
MSGSOFTPARA(Optional)

SET
MSGSOFTPARA(Optional)
SET
MSGSOFTPARA(Optional)
SET
MSGSOFTPARA(Optional)
SET
BTSCHNFALLBACK(Mandator
y)
SET
BTSCHNFALLBACK(Mandator
y)
SET
BTSCHNFALLBACK(Mandator
y)

SET ETHPORT(Optional)

SET GCELLHOAD(Optional)

SET GCELLHOAD(Optional)

SET GCELLPSBASE(Optional)

ADD
GCNOPERATOR(Optional)

ADD GNRNC(Optional)

ADD GNRNC(Optional)

SET GCELLGPRS(Optional)

SET GCELLGPRS(Optional)

SET
BSCPSSOFTPARA(Optional)

ADD GCNNODE(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)

SET BSCBASIC(Optional)

SET GCELLGPRS(Optional)

SET BTSRXUBP(Optional)

SET FTPSCLT(Optional)

ADD OPC(Mandatory)
ADD N7DPC(Mandatory)
ADD M3LE(Mandatory)

ADD BTS(Mandatory)

ADD
BTSAUTOPLAN(Mandatory)

ADD BTSCABINET(Optional)

ADD G2GNCELL(Mandatory)
ADD
GIBCAPNCGRP(Mandatory)

ADD G2GNCELL(Mandatory)
ADD
GIBCAPNCGRP(Mandatory)

ADD G3GNCELL(Mandatory)

ADD G3GNCELL(Mandatory)

ADD G2GNCELL(Mandatory)

RUN BATCHFILE(Mandatory)

SET CLKMODE(Mandatory)

ADD CLKSRC(Mandatory)

ADD G2GNCELL(Optional)

ADD BTSBFD(Mandatory)
ADD G2GNCELL(Mandatory)

ADD G2GNCELL(Mandatory)
PING MAC(Mandatory)
TRC MAC(Mandatory)
ADD G2GNCELL(Mandatory)
ADD TSCROSS(Mandatory)

ADD CLKSRC(Mandatory)

ADD TSCROSS(Mandatory)

ADD M3LNK(Mandatory)
atory)
SET
CFGDATAEFFECTIVE(Optiona
l)
SET MSPCMD(Mandatory)
SET E1T1LOP(Mandatory)
LOP E1T1(Mandatory)
STR E1T1TST(Mandatory)
SET OPTLOP(Mandatory)
PING IP(Mandatory)
TRC IPADDR(Mandatory)
SWP ETHPORT(Mandatory)
SET QUEUEMAP(Mandatory)
SET E1T1(Mandatory)
SET MSP(Mandatory)
ADD TSCROSS(Mandatory)
ADD DEVIP(Mandatory)
ADD IPRT(Mandatory)
SET OPT(Mandatory)
SET COPTLNK(Mandatory)
SET ETHPORT(Mandatory)
ADD
ETHREDPORT(Mandatory)
ADD PPPLNK(Mandatory)
ADD MPGRP(Mandatory)
ADD MPLNK(Mandatory)
ADD ETHIP(Mandatory)
ADD
IPLOGICPORT(Mandatory)
ADD
ICMPGUARD(Mandatory)
STR IPCHK(Mandatory)
ADD SUBRACK(Mandatory)
SET CLK(Mandatory)

ADD GCBSADDR(Mandatory)
SET TCPLYVOICE(Mandatory)
SET TCPARA(Mandatory)
ADD NSE(Mandatory)

EXP ALMLOG(Optional)
STA ALMLOG(Optional)
ADD
OBJALMSHLD(Mandatory)
ADD BTSBFD(Optional)
ADD BTSIPRTBIND(Optional)
ADD
GIURGCONN(Mandatory)
ADD MTP3LNK(Optional)
ADD SCTPLNK(Mandatory)

ADD RSCGRP(Mandatory)
SET PHBMAP(Mandatory)
ADD ATERE1T1(Mandatory)
ADD AE1T1(Mandatory)
BLK AE1T1(Mandatory)
ADD
ABISLOADSHARE(Mandatory
)
ADD PBE1T1(Mandatory)

BLK ATERE1T1(Mandatory)

COL LOG(Optional)

ADD ETHMD(Mandatory)
ADD ETHTRK(Mandatory)
ADD
ETHTRKLNK(Mandatory)
ADD ETHTRKIP(Mandatory)
STR
ETHMIRRORPORT(Mandatory
)
ADD PBSL(Mandatory)

SET BTSDPMUBP(Mandatory)
SET BTSDTMUBP(Mandatory)
SET BTSDGPSBP(Mandatory)
SET BTSDDPUBP(Mandatory)
SET BTSUSCUBP(Mandatory)
SET BTSRXUBP(Mandatory)
ADD
BTSRXU2LOCGRP(Mandatory
)
ADD
BTSBINDLOCGRP(Mandatory
)
ADD
BTSANTFEEDERBRD(Mandat
ory)
ADD BTSBRD(Mandatory)
ADD BTSRXUBRD(Optional)
ADD
BTSTRXBRD(Mandatory)
SET
BTSENVALMPORT(Mandatory
)
SET
BTSANTFEEDERCONNECT(M
andatory)
ADD
BTSOBJALMSHLD(Mandatory
)
LOD RETANTCFG(Mandatory)
SET
BTSANTANGLE(Mandatory)
SET
BTSCLKPARA(Mandatory)

ADD BTSSFPMODE(Optional)
SET BTSFORBIDTS(Optional)
SET BTSOMLTS(Optional)
SET BTSETHPORT(Optional)
ADD BTSPPPLNK(Optional)
ADD BTSMPLNK(Optional)
ADD BTSETHMA(Optional)
ADD
BTSETHLCMEP(Optional)
ADD
BTSTOPCONFIG(Optional)
IMP BTSPPPLNK(Optional)
IMP BTSMPLNK(Optional)

ADD
BTSCONNECT(Mandatory)
OPR
BTSBRDPWR(Mandatory)
ADD
SRCONPATH(Mandatory)
ADD
SRCONPATH(Mandatory)
ADD SUBRACK(Mandatory)

SET BTSTMA(Mandatory)

SET CLK(Mandatory)

EXP ALMLOG(Optional)

ADD NSVLLOCAL(Optional)

ADD NSVLREMOTE(Optional)

SET BTSPSUFP(Optional)
ADD
BTSABISMUXFLOW(Mandato
ry)

SET
GCELLHOFITPEN(Optional)

SET CPUTHD(Optional)

SET CPUTHD(Optional)

SET CPUTHD(Optional)

SET CPUTHD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

STR BKP(Optional)
ULD RSTINFO(Mandatory)
ADD XPUVLAN(Mandatory)
LOD BRD(Optional)
CMP TBLDATA(Mandatory)

ADD
GIURGCONN(Mandatory)
EXP ALMLOG(Optional)

SET
GCELLHOFITPEN(Optional)

EXP ALMLOG(Optional)

STA ALMLOG(Optional)

EXP LOG(Optional)

ADD SUBTSK(Mandatory)

COL LOG(Optional)

ADD GSMSCB(Mandatory)

SET TZ(Mandatory)
EXP ALMLOG(Optional)
STA ALMLOG(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

BLK ACIC(Mandatory)

BLK PBCIC(Mandatory)

ADD
BSCDSTPADATE(Mandatory)

SET BTSDHEUBP(Optional)

ADD
BSCDSTPADATE(Mandatory)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

SET BTSFORBIDTS(Optional)

SET BTSFALLBACK(Optional)

SET BSCDSTPA(Optional)

BLK AE1T1(Mandatory)

BLK ATERE1T1(Mandatory)

SET
BTSFORBIDTS(Mandatory)

SET BTSFMUABP(Optional)

SET BTSNFCBBP(Optional)

ADD AE1T1(Mandatory)

ADD
BTSMONITORTS(Optional)
ADD OP(Mandatory)

STR NCS(Mandatory)

ADD MTP3LNK(Optional)
STR BTSLOG(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET BTSFALLBACK(Optional)
ADD N7DPC(Optional)
ADD
BTSMONITORTS(Mandatory)
SET
GCELLFREQSCAN(Optional)
ADD
BTSMONITORTS(Optional)
ADD
BTSMONITORTS(Optional)

ADD
BTSMONITORTS(Mandatory)

ADD OP(Mandatory)
ADD
BTSMONITORTS(Mandatory)

SET
BTSAUTODLDACTINFO(Optio
nal)

BLK ACIC(Mandatory)

ADD AE1T1(Mandatory)

STR BTSLOG(Optional)

ADD IPMUX(Optional)

ADD
BTSABISMUXFLOW(Optional)

ADD SUBTSK(Mandatory)
ADD SUBCMD(Mandatory)
SET SUBNET(Mandatory)

SET GCELLSOFT(Optional)
SET
BTSFLEXABISPARA(Optional)
SET BTSOMLTS(Mandatory)
SET
BTSAUTODLDACTINFO(Mand
atory)

SET OTHSOFTPARA(Optional)

SET CLK(Optional)

SET CLK(Optional)

SET GCELLSBC(Optional)

SET
BSCPSSOFTPARA(Optional)

SET GCELLGPRS(Optional)

SET
BSCPSSOFTPARA(Optional)

SET GCELLGPRS(Optional)

SET BSSLS(Optional)

SET BSCBASIC(Optional)

ADD GNRNC(Optional)

SET GCELLPRACH(Optional)

ADD NSE(Mandatory)

ADD NSE(Mandatory)

SET ALMPORT(Optional)

SET ASWPARA(Mandatory)

SET OBJAUTHSW(Mandatory)
SET
BTSENVALMPORT(Mandatory
)
OPR
BTSBRDPWR(Mandatory)
SET TZ(Mandatory)

SET SCUPORT(Mandatory)
SET
BFDPROTOSW(Mandatory)

SET
LICENSECTRL(Mandatory)
SET SLFSLVSW(Mandatory)
SET
BTSALMPORT(Mandatory)
SET BTSETHPORT(Optional)

ADD SCTPLNK(Optional)

ADD SCTPLNK(Optional)
SET
SS7PATCHSWITCH(Optional)
SET
SS7PATCHSWITCH(Optional)
SET
SS7PATCHSWITCH(Optional)
SET
SS7PATCHSWITCH(Optional)
SET
SS7PATCHSWITCH(Optional)
SET
SS7PATCHSWITCH(Optional)
SET
SS7PATCHSWITCH(Optional)
SET
SS7PATCHSWITCH(Optional)
SET
SS7PATCHSWITCH(Optional)

SET
SS7PATCHSWITCH(Optional)
ADD BTSSFPMODE(Optional)

SET OPSW(Mandatory)

SET TZ(Mandatory)

SET BTSAISS(Optional)

ADD
GEXT3GCELL(Mandatory)
SET BTSOTHPARA(Optional)
SET
BTSIPCLKPARA(Mandatory)
SET BTSIPCLKPARA(Optional)

SET BTSIPCLKPARA(Optional)

SET BTSIPCLKPARA(Optional)

SET SYS(Optional)

SET SYS(Optional)

SET GCELLHOAD(Optional)

SET SYS(Optional)

SET BSCBASIC(Optional)

SET SYS(Optional)

SET SYS(Optional)
CHG
BTSPTUSHKTM(Optional)
SET BSSGPPARA(Optional)

SET MTP3TMR(Optional)

SET MTP3TMR(Optional)

SET MTP3TMR(Optional)

SET MTP3TMR(Optional)

SET MTP3TMR(Optional)

SET MTP3TMR(Optional)
CHG
BTSPTUSHKTM(Optional)
SET BSSGPPARA(Optional)

SET BTSRINGATTR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET GCELLCCTMR(Optional)

SET BTSRINGATTR(Optional)

SET MTP3TMR(Optional)

SET MTP3TMR(Optional)

SET MTP3TMR(Optional)
CHG
BTSPTUSHKTM(Optional)
SET BSSGPPARA(Optional)

SET GCELLHOAD(Optional)

SET GCELLGSMR(Optional)

SET GCELLPSBASE(Optional)

SET GCELLPSBASE(Optional)

SET
GCELLIDLEBASIC(Optional)

ADD BC(Optional)

SET MTP3TMR(Optional)

SET BSSGPPARA(Optional)

SET MTP3TMR(Optional)

SET BSSGPPARA(Optional)

SET MTP3TMR(Optional)

SET BSSGPPARA(Optional)

SET BSSGPPARA(Optional)

SET MTP3TMR(Optional)

SET
GCELLHOFITPEN(Optional)

SET GCELLHOIUO(Optional)

SET
GCELLHOBASIC(Optional)

SET GCELLHOIUO(Optional)

ADD G2GNCELL(Optional)

SET GCELLHOEMG(Optional)

SET GCELLGSMR(Optional)

SET
GCELLHOFITPEN(Optional)

ADD AISSCFG(Mandatory)
ADD NCELL(Mandatory)
COL SYNCINFO(Mandatory)
SET
BTSEXCURSION(Mandatory)
SET
BSCSYNCOFF(Mandatory)
COL
BSCSYNCINFO(Mandatory)

ADD G2GNCELL(Optional)

SET GCELLHOIUO(Optional)

SET
GCELLPSPWPARA(Optional)

SET
GCELLPSPWPARA(Optional)

EXP DEVFILE(Optional)

EXP BTSDEVFILE(Optional)

SET
BTSOMLBACKUP(Optional)

SET BTSRINGATTR(Optional)

ADD MTP3LNK(Optional)

SET BSSGPPARA(Optional)

SET BTSAPMUBP(Optional)

SET BSCBASIC(Optional)

SET GTRXDEV(Optional)

SET
GCELLCHMGAD(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLOTHEXT(Optional)

SET GCELLHOCTRL(Optional)

SET GCELLPWR3(Optional)

SET OTHSOFTPARA(Optional)

SET GCELLSOFT(Optional)

SET GCELLSOFT(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

ADD MTP3LNK(Optional)

ADD MTP3LNK(Mandatory)

SET GCELLSOFT(Optional)

ADD
BTSRXUCHAIN(Mandatory)
CBN
BTSRXUCHAIN(Mandatory)

ADD
ATERCONPATH(Mandatory)
SET BSCBASIC(Mandatory)
ADD
ATERCONPATH(Mandatory)
ADD
ATERCONPATH(Mandatory)

SET TCTYPE(Mandatory)

SET
GCELLIDLETDDBA1(Mandato
ry)
SET
GCELLHOTDDBA2(Mandator
y)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLIDLETDDBA1(Mandato
ry)
SET
GCELLIDLETDDBA1(Mandato
ry)

SET
GCELLCCUTRANSYS(Optiona
l)

SET
GCELLCCUTRANSYS(Optiona
l)
ADD GEXT3GCELL(Optional)

SET
GCELLHOTDDBA2(Mandator
y)

SET
GCELLIDLETDDBA1(Mandato
ry)

SET
GCELLCCUTRANSYS(Optiona
l)
SET
GCELLIDLETDDBA1(Mandato
ry)
SET
GCELLHOTDDBA2(Mandator
y)
ADD TRMLOADTH(Optional)
ADD TRMLOADTH(Optional)
ADD
SRCONPATH(Mandatory)
ADD
SRCONPATH(Mandatory)

ADD PBSL(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET BTSDPMUBP(Optional)
SAV
GCELLTEMPLATE(Optional)
EXP
GCELLTEMPLATE(Mandatory)
SAV
GCELLTEMPLATE(Optional)

ADD GCELL(Optional)
ADD
BTSAUTOPLAN(Optional)
EXP
GCELLTEMPLATE(Mandatory)
SAV
GCELLTEMPLATE(Mandatory)
ADD
GCELLQUICKSETUP(Optional
)

SET BTSAPMUBP(Optional)

SET BTSAPMUBP(Optional)

SET BTSDPMUBP(Optional)

SET OTHSOFTPARA(Optional)

SET BSCNSPARA(Optional)

ADD GSMSCB(Mandatory)

SET TCPARA(Optional)

STR BTSVSWRTST(Optional)

SET GCELLOTHEXT(Optional)

SWP OMUAREA(Mandatory)

ADD TGWIP(Mandatory)

ADD TGWIP(Mandatory)

ADD TGWIP(Mandatory)

ADD TGWIP(Mandatory)

ADD TGWIP(Mandatory)

SET BSSGPPARA(Optional)

SET BTSAIRCON(Optional)

SET BTSAIRCON(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)

SET GCELLPSCHM(Optional)
ADD
TRMLOADTH(Mandatory)
SET BSCTMR(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLHOBASIC(Optional)

SET GCELLHOAD(Optional)

SET
GCELLHOBASIC(Optional)

SET GCELLHOAD(Optional)

SET
GCELLCHMGBASIC(Optional)

SET
GCELLCHMGAD(Optional)

ADD
GCNOPERATOR(Optional)

SET
GCELLFREQSCAN(Optional)
SET TIME(Optional)

ADD OP(Optional)

SET
GCELLHOFITPEN(Optional)

SET
GCELLHOFITPEN(Optional)

SET GCELLHOIUO(Optional)

ADD
BTSABISMUXFLOW(Optional)

PING IP(Optional)
TRC IPADDR(Optional)
PING MAC(Optional)
PING BTSCFM(Optional)
TRC MAC(Optional)
TRC BTSCFM(Optional)

ADD GEXT2GCELL(Optional)
SET GCELLHOFAST(Optional)

PING IP(Optional)

SET
GCELLBASICPARA(Optional)

SET
GCELLHOFITPEN(Optional)

SET GCELLHOIUO(Optional)

SET GCELLTMR(Optional)

ADD
GCNOPERATOR(Optional)
SET LOGLIMIT(Optional)

SET MSTOCELL(Mandatory)
TST SNDRSI(Mandatory)
TST UPDMSRAC(Mandatory)

SET BTSDHEUBP(Optional)

SET BTSAPMUBP(Optional)

SET BTSDHEUBP(Optional)

ADD SUBTSK(Mandatory)

ADD SUBTSK(Mandatory)

ADD SUBTSK(Optional)

ADD SUBTSK(Optional)

ADD SUBTSK(Optional)

ADD SUBTSK(Optional)
ADD TRMMAP(Mandatory)
ADD ADJMAP(Mandatory)
STR
FRPORTLOOP(Mandatory)
STR BTSVSWRTST(Optional)

SET GCELLSOFT(Optional)

SET ALMBLKPARA(Optional)

CHK INNSPCH(Mandatory)
STR
CALLRESLOP(Mandatory)
ADD
GCSCHRUSER(Mandatory)

SET ALMBLKPARA(Optional)

SET MTP3TMR(Optional)

SET MTP3TMR(Optional)

CMP TBLDATA(Optional)

ADD PBE1T1(Optional)

ADD ATERSL(Optional)
ADD ATERCONSL(Optional)

SET GCELLIDLEAD(Optional)

SET TZ(Mandatory)
ADD
BTSTOPCONFIG(Optional)
ADD
BTSTOPCONFIG(Mandatory)
ADD
BTSTOPCONFIG(Optional)

COL FAMLOG(Mandatory)

ADD
BTSRXUCHAIN(Mandatory)
CBN
BTSRXUCHAIN(Mandatory)

SET GCELLTMR(Optional)

SET FCCPUTHD(Optional)

SET FCMSGQTHD(Optional)

SET FCCPUTHD(Optional)

SET FCMSGQTHD(Optional)

SET FCSW(Optional)

SET
BSCPSSOFTPARA(Optional)

SET
BSCPSSOFTPARA(Optional)

ADD M3LKS(Optional)

SET BTSTRANS(Mandatory)

ADD
ABISLOADSHARE(Mandatory
)
ADD IPPATH(Optional)

ADD TRMMAP(Optional)

ADD
TRMLOADTH(Mandatory)

SET BTSBWPARA(Mandatory)
SET
BSCABISPRIMAP(Mandatory)

SET BTSDOMUBP(Optional)

SET BTSDOMUBP(Optional)

SET BTSDOMUBP(Optional)

SET BTSDOMUBP(Optional)

SET
BTSCLKPARA(Mandatory)
SET
GCELLRESELECTPARA(Optio
nal)
SET GCELLHOAD(Optional)
ADD
ETHTRKLNK(Mandatory)
ADD
ETHTRKLNK(Mandatory)
ADD ETHTRK(Mandatory)
ADD
ETHTRKLNK(Mandatory)
ADD ETHTRKIP(Mandatory)
SET
BSCABISPRIMAP(Mandatory)
ADD PPPLNK(Optional)
ADD MPGRP(Optional)

ADD IPPATH(Optional)
ADD IPLOGICPORT(Optional)
ADD RSCGRP(Optional)
ADD
TRMLOADTH(Mandatory)

SET
BSCABISPRIMAP(Mandatory)

SET
BSCABISPRIMAP(Optional)
ADD ETHMEP(Mandatory)
STR IPCHK(Optional)
ADD IPLOGICPORT(Optional)

SET
GCELLCCACCESS(Optional)

STR BTSTST(Mandatory)

SET
GTRXCHANHOP(Optional)

SET FHO(Mandatory)
SET
GTRXCHANHOP(Mandatory)
SET GTRXHOP(Mandatory)
SET GTRXBASE(Mandatory)
SET GTRXCHAN(Mandatory)
SET GTRXFC(Mandatory)
SET GTRXIUO(Mandatory)
SET
GTRXADMSTAT(Mandatory)
SET
GTRXCHANADMSTAT(Mandat
ory)
ADD GTRX(Mandatory)
ADD
TRXBIND2PHYBRD(Mandator
y)
SET GTRXRLALM(Mandatory)
SET GTRXDEV(Mandatory)
ADD
GTRXBIND2HDLCPATH(Mand
atory)
STR BTSTST(Mandatory)
STR
TRXBURSTTST(Mandatory)

ADD
BTSBINDLOCGRP(Mandatory
)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)

ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)

ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
ADD
GCELLHOPANTGRP(Optional)
STR
TRXPERFTST(Mandatory)
SET
GCELLHOPQUICKSETUP(Opti
onal)
SET
GCELLHOPANTQUICKSETUP(
Optional)
SET
GTRXCHANHOP(Optional)
ADD GTRX(Optional)
ADD
BTSBRDCAP(Mandatory)
ADD BTSRXUBRD(Optional)
ADD
BTSBINDLOCGRP(Mandatory
)
ADD
TRXBIND2PHYBRD(Mandator
y)

SET
GCELLCHMGAD(Optional)

ADD
TRXBIND2PHYBRD(Mandator
y)

BLK AE1T1(Mandatory)

BLK ATERE1T1(Mandatory)

ADD BC(Mandatory)

LOP E1T1(Mandatory)
STR E1T1TST(Optional)

SET BTSOMLTS(Mandatory)

ADD BTSPPPLNK(Mandatory)
ADD BTSMPLNK(Mandatory)
IMP BTSPPPLNK(Mandatory)
IMP BTSMPLNK(Mandatory)

ADD PPPLNK(Mandatory)

ADD MPLNK(Mandatory)

ADD GCELLMAGRP(Optional)

SET BTSIDLETS(Mandatory)

SET GCELLSOFT(Optional)

ADD TSCROSS(Optional)
STR
TRANSPERFTST(Mandatory)
ADD
BTSMONITORTS(Optional)
ADD SCHTSK(Mandatory)
SET SCHTSKSW(Optional)
ADD SUBTSK(Optional)
ADD SUBCMD(Optional)
STR SCHTSK(Optional)

ADD ATEROML(Mandatory)

ADD
BTSABISHDLCPATH(Mandato
ry)
ADD
BTSTOPCONFIG(Mandatory)

ADD
BTSRXUCHAIN(Mandatory)
CBN
BTSRXUCHAIN(Mandatory)

ADD PBSL(Mandatory)

SET GTRXCHAN(Optional)

SET GTRXDEV(Optional)

SET
BSCPSSOFTPARA(Optional)

SET
BSCPSSOFTPARA(Optional)

ADD
BTSMONITORTS(Mandatory)

ADD
BTSRXUCHAIN(Mandatory)
CBN
BTSRXUCHAIN(Mandatory)

STR BTSTST(Mandatory)

STR
TRANSPERFTST(Mandatory)
STR
BTSBATTTST(Mandatory)
STR BTSRFTST(Mandatory)

SET BSCDSTPA(Optional)

ADD
BTSRXUCHAIN(Mandatory)
PING IP(Optional)
TRC MAC(Optional)
TRC BTSCFM(Optional)

SET
GCELLDYNTURNOFF(Optiona
l)
SET
GCELLDYNTURNOFF(Optiona
l)

SET
GCELLDYNTURNOFF(Optiona
l)

SET
GCELLDYNTURNOFF(Mandat
ory)

SET
GCELLDYNTURNOFF(Optiona
l)

SET BTSAPMUBP(Optional)

SET BTSDHEUBP(Optional)

ADD AISSCFG(Optional)

ADD AISSCFG(Optional)

ADD AISSCFG(Optional)

ADD AISSCFG(Optional)

ADD AISSCFG(Optional)

ADD AISSCFG(Optional)

ADD AISSCFG(Optional)

SET
GCELLIDLEBASIC(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

ADD IPPATH(Mandatory)

ADD RSCGRP(Mandatory)

SET GCELLPRACH(Optional)
PING IP(Optional)

ADD
BTSAUTOPLAN(Mandatory)

ADD SUBRACK(Mandatory)

ADD GCELL(Mandatory)

SET
BSCPCUTYPE(Mandatory)

RUN BATCHFILE(Mandatory)

ADD BTSCABINET(Optional)

ADD
GCELLQUICKSETUP(Mandato
ry)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSANTFEEDERCONNECT(O
ptional)

SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
BTSANTFEEDERCONNECT(O
ptional)
SET
CSABISCONGCTRL(Optional)
SET
CSABISCONGCTRL(Optional)
SET
CSABISCONGCTRL(Optional)
SET
CSABISCONGCTRL(Optional)
SET
CSABISCONGCTRL(Optional)
SET
CSABISCONGCTRL(Optional)
SET
CSABISCONGCTRL(Optional)
SET
CSABISCONGCTRL(Optional)
SET
CSABISCONGCTRL(Optional)
SET
CSABISCONGCTRL(Optional)

SET
CSABISCONGCTRL(Optional)
SET
MSGSOFTPARA(Optional)

SET OTHSOFTPARA(Optional)
SET
PSPREFABISCONGCTRL(Opti
onal)
SET
PSPREFABISCONGCTRL(Opti
onal)
SET
PSPREFABISCONGCTRL(Opti
onal)
SET
PSPREFABISCONGCTRL(Opti
onal)
SET
PSPREFABISCONGCTRL(Opti
onal)
SET
PSPREFABISCONGCTRL(Opti
onal)
SET
PSPREFABISCONGCTRL(Opti
onal)
SET
PSPREFABISCONGCTRL(Opti
onal)
SET
PSPREFABISCONGCTRL(Opti
onal)
SET
PSPREFABISCONGCTRL(Opti
onal)
SET
PSPREFABISCONGCTRL(Opti
onal)

SET AITFOTHPARA(Optional)

ADD IPMUX(Mandatory)

ADD IPMUX(Mandatory)

ADD NSVLLOCAL(Mandatory)

ADD
NSVLREMOTE(Mandatory)

ADD OP(Optional)

SET BTSEXD(Optional)

SET GCELLGSMR(Optional)
STR E1T1TST(Optional)
SET ALMPORT(Optional)

SET
BTSENVALMPORT(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

ADD G2GNCELL(Optional)

ADD G2GNCELL(Optional)

SET
BSCPSSOFTPARA(Optional)

SET GCELLTMR(Optional)

SET
BSCPSSOFTPARA(Optional)

SET
GCELLHOBASIC(Optional)

SET
BSCPSSOFTPARA(Optional)
SET
BSCPSSOFTPARA(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET
GCELLHOINTERRATLDB(Opti
onal)

SET GCELLPWR2(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET
GCELLHOINTERRATLDB(Opti
onal)

SET GCELLPWR2(Optional)

SET
GCELLPWRBASIC(Optional)

SET
GCELLPWRBASIC(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLPWR2(Optional)

SET GCELLHOEMG(Optional)

SET
GCELLAMRQUL(Optional)

SET
GCELLAMRQUL(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET GCELLPWR3(Optional)

SET
GCELLPWRBASIC(Optional)

SET
GCELLPWRBASIC(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLCCAMR(Optional)

SET GCELLHOIUO(Optional)

SET
BSCPSSOFTPARA(Optional)

SET GCELLSOFT(Optional)

SET
GCELLHOFITPEN(Optional)

SET BSCBASIC(Optional)

SET E1T1(Optional)

SET BSCNSPARA(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

SET BTSRXUBP(Optional)

ADD
BTSAUTOPLAN(Mandatory)
ADD
BTSCONNECT(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)
ADD
BTSCONNECT(Mandatory)
ADD
BTSAUTOPLAN(Mandatory)
ADD
BTSCONNECT(Mandatory)
ADD GSMSCB(Mandatory)

SET GCELLPSCS(Optional)

SET
GCELLEGPRSPARA(Optional)

SET GCELLPSCHM(Optional)

SET
GCELLEGPRSPARA(Optional)

SET
GCELLEGPRSPARA(Optional)

SET
GCELLPRIVATEOPTPARA(Opti
onal)

SET GCELLPSCS(Optional)

SET
GCELLEGPRSPARA(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET BTSFALLBACK(Optional)

SET BTSLAPDWS(Optional)

SET
GCELLBASICPARA(Optional)

ADD RSCGRP(Mandatory)
ADD IPLOGICPORT(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET
GCELLCHMGAD(Optional)

SET GCELLCCAD(Optional)

SET
GCELLPRIVATEOPTPARA(Opti
onal)

SET GCELLPSCS(Optional)

SET GCELLPSCS(Optional)

SET GCELLPSCS(Optional)

SET GCELLPSCS(Optional)

SET GCELLPSCS(Optional)

SET GCELLPSCS(Optional)

SET
GCELLNC2PARA(Optional)

CHK INNSPCH(Mandatory)
STR
CALLRESLOP(Mandatory)
ADD
GCSCHRUSER(Mandatory)

SET
BSCPSSOFTPARA(Optional)
DLD LICENSE(Mandatory)
ULD LICENSE(Mandatory)

DLD RETANTCFG(Mandatory)
ULD
BTSDEVFILE(Mandatory)
DLD BTSPATCH(Mandatory)
ULD BTSLOG(Mandatory)
DLD BTSSW(Mandatory)

SET
BTSDOMUBP(Mandatory)
SET
BTSDOMUBP(Mandatory)

SET BTSEXD(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

SET GCELLHOIUO(Optional)

ADD
GEXT3GCELL(Mandatory)
ADD BTSRETANT(Mandatory)

SET GCELLGSMR(Optional)

SET GCELLGSMR(Optional)

SET GCELLGSMR(Optional)

SET BSCFCPARA(Optional)

ADD GCELL(Optional)

SET BSCFCPARA(Optional)

SET BSCFCPARA(Optional)

ADD IPPATH(Optional)
SET
BSCABISPRIMAP(Optional)

ADD SCTPLNK(Optional)

ADD SCTPLNK(Optional)

ADD IPPATH(Mandatory)
ADD VLANID(Mandatory)
SET BTSVLAN(Optional)
IMP BTSVLAN(Optional)
ADD ETHMA(Mandatory)
ADD BTSETHMA(Mandatory)

ADD SCTPLNK(Mandatory)

ADD SCTPLNK(Mandatory)

SET BTSVLAN(Optional)
IMP BTSVLAN(Optional)

SET DSCPMAP(Optional)
SET BTSVLAN(Optional)
IMP BTSVLAN(Optional)

SET
GCELLCCACCESS(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

ADD EMU(Optional)

SET BTSDFCUBP(Optional)

SET GCELLOTHEXT(Optional)

SET BTSDFCUBP(Optional)
SET BTSDDPUBP(Optional)

SET BTSDFCUBP(Optional)
SET BTSDDPUBP(Optional)

SET BTSDFCUBP(Optional)
SET BTSDDPUBP(Optional)

SET GCELLOTHEXT(Optional)
SET
BTSAUTODLDACTINFO(Mand
atory)
SET GCELLTMR(Optional)

SET GCELLTMR(Optional)

SET GCELLTMR(Optional)

ADD GEXTSMLC(Optional)

SET GCELLTMR(Optional)

SET
GCELLCHMGAD(Optional)

ADD GEXTSMLC(Optional)

SET BTSOUTPUT(Optional)

ADD EMU(Optional)

ADD OP(Optional)

SET GCELLLCS(Optional)

SET BTSOUTPUT(Optional)

STR IPCHK(Optional)

SET OTHSOFTPARA(Optional)

ADD OP(Mandatory)
ADD M3LKS(Optional)

SET GTRXRLALM(Optional)

SET GTRXRLALM(Optional)

SET GTRXRLALM(Optional)

SET GTRXRLALM(Optional)

SET GTRXRLALM(Mandatory)

FMT DATA(Optional)

SET BTSRXUBP(Optional)

ADD SUBRACK(Mandatory)

SET E1T1(Optional)

ADD BTS(Optional)

ADD ATERSL(Optional)
ADD ATERCONSL(Optional)
SET
BTSOMLBACKUP(Optional)

SET BTSRINGATTR(Optional)

SET MSP(Optional)

SET TZ(Optional)

Meaning
Downlink quality level threshold for the MS to be assigned with a channel of the
better cell.
Uplink quality level threshold for the MS to be assigned with a channel of the
better cell.

The maximum duration for the BSC to select the best cell according to MRs in
the MS assigning procedure. The BSC assigns the channel of the serving cell to
the MS if the best cell is not selected within the duration specified by this
parameter.

Whether to enable the BTS to support bypass function. HDLC BTS and IP BTS do
not support this parameter.
Whether to permit Abis flow control.
The flow control function helps in better call management. If congestion occurs,
the system lightens its load by rejecting some services or prolonging the time
for service requests. The Abis flow control is used to lighten the system load
caused by Abis flows.
Used along with "Abis Flow Control Timer 2" to control the change in cell flow
control levels.When the flow control level in the cell changes, the values of MS
MAX Retrans and Tx-integer in the system information are changed accordingly.
When immediate assignment fails, the BSC6900 starts T1 and T2.
Used along with "Abis Flow Control Timer 1" to control the change in cell flow
control levels.When the flow control level in the cell changes, the values of MS
MAX Retrans and Tx-integer in the system information are changed accordingly.
When immediate assignment fails, the BSC6900 starts T1 and T2.

This parameter controls the strategy for idle timeslot selection and optimization
by the PS channels.

This parameter controls whether the strategy for timeslot configuration and
optimization is started. When this parameter is set to ON, the bundled idle
timeslots for the PS channel should be allocated to the same 64 kbit/s timeslot
as the primary link. When this parameter is set to OFF, the idle channels are
allocated randomly in the transport pool of a site.
Threshold for enabling the BTS local switching. When the congestion rate at the
Abis interface exceeds this threshold, the BTS local switching is enabled.
This parameter specifies whether to enable the Abis resource adjustment TCHH
function.
It specifies whether the TCHH is preferentially allocated to the MS by the
BSC6900, when Abis resources are insufficient.
If the Abis resource load is greater than "Flex Abis Prior Choose Load Thred" or
"Fix Abis Prior Choose Abis Load Thred" when the parameter is set to "YES", the
BSC6900 preferentially allocates the TCHH to the MS.

Interval between detection of the Abis timeslot being in idle state and releasing
of the Abis timeslot. When channels are idle, the timer is started. When the
timer is expires, the Abis timeslot is released. When all the TBFs on the channel
are released, the Abis timeslot is not released at once. Instead, the timer is
started when the channels are idle. Before the timer expires, if new service
request is received and the Abis timeslot is occupied, then the timer is stopped;
otherwise, the timeslot is released after the timer expires.
When "Number of Dynamic Channel Pre-Converted" is greater than 0, the Abis
timeslots are not released after the static PDCH and pre-converted PDCH are
idle.

Phase tag for GSM protocols that the Abis interface supports

Duration available for the BTS to collect the AB after the TRX or channel is
activated.
Mean opinion score (threshold) for judging an abnormal call. The BTS computes
the MOS of a call periodically and reports the call MOS to the BSC in custom
measurement reports. According to the call MOS, the BSC checks whether the
call is normal. If the call MOS is less than this threshold, the BSC considers the
call abnormal and records the abnormity in the call history record (CHR).
To prevent the impact of a decimal fraction, set this parameter to the product of
50 and the actual MOS.

Access pulse type of the PRACH, uplink PTCCH and packet control acknowledge
message of the MS.
8bit: 8 bit pulse access mode; 11bit: 11 bit pulse access mode.
Access control class of the MS
When the cell supports Repeated This parameter specifies whether the access
control function is enabled in a cell. When the function is enabled, the BSC
determines which MSs in the cell to be connected to the network by sending
the ACC classes through system messages according to the specified policy in
Access Control Policy.
This parameter specifies the index of the access control policy that is used in a
cell.
Subcell preferred during the incoming inter-BSC handover to the concentric cell.
In the case of incoming inter-BSC handover to the concentric cell, the channels
in this subcell are preferred.
This parameter specifies the index of an access control (ACC) policy. It is used
to identify an ACC policy.
Whether the initial service is uplink, downlink or neutral
This parameter is used to specify the starting point of the ACC sliding window in
an access control policy.
This parameter is used to specify the ACC sliding window size in an access
control policy. MSs of the ACC access classes that are specified in the sliding
window are not allowed to access the network.
This parameter is used to specify the sliding speed of the ACC sliding window in
an access control policy.

A flag bit indicates Whether to support the compression of the address and
control fields.

Whether to compress the address and control fields. If this parameter is set to
ENABLE, the address and control area compression is enabled. If this parameter
is set to DISABLE, the address and control area compression is disabled.

This parameter specifies whether to receive the CS paging request from A


interface when the MS uses a PS service. This parameter is used to control the
paging collaboration function of A interface of the entire BSC. This parameter
specifies whether to forward the paging message of the A interface from the
circuit domain to the PS domain .

Used for notifying MSs where to retrieve relevant parameters during cell
reselection.
The default value of this parameter is 0 in system message 3 and, has no
special significance.
In system message 4, if the value of this parameter is 0, it means that the MSs
must retrieve the PI parameters and other parameters relevant to cell
reselection and the parameters relevant to C2 calculation from the remaining
bytes of system message 4.If the value is 1, it means that the MS must retrieve
the parameters from the remaining bytes of system message 7 or 8.

Active coding set (ACS)[F], indicates a set of full-rate coding rates currently
available for calls. The AMR is a set of multiple speech coding and decoding
rates.

Active coding set (ACS)[H], indicates set of half-rate coding rates currently
available for calls. The AMR is a set of multiple speech coding and decoding
rates.

Active coding set (ACS)[WB], indicates a set of wide-band coding rates currently
available for calls. The AMR is a set of multiple speech coding and decoding
rates.

Whether to activate the function of L2 re-establishment. If this function is


activated, the BSC starts the attempt of L2 re-establishment when the BSC
receives an ERR IND message reported by the BTS in a conversation of MSs. If
the L2 re-establishment succeeds, the conversation continues; otherwise, a call
drop occurs.

Valid duration of the reserved TRX or timeslot

AC voltage alarm lower threshold. When the input AC voltage is lower than the
value of this parameter, an alarm indicating the abnormal AC is reported.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

The BTS reports an alarm if the AC voltage exceeds the value of this parameter.
The BTS reports an alarm if the AC voltage is lower than the value of this
parameter.
The BTS reports an alarm if the AC voltage exceeds the value of the AC voltage
alarm upper threshold. When the input AC voltage is higher than the value of
this parameter, an alarm indicating the abnormal AC is reported.
In multi-mode scenario, the value of this parameter must be the same as the
value of the parameter in other modes.

Whether to hand over an MS to another channel during an intra-cell handover


through the assignment process

Communication address of the CBUS3 on the bus 485. The configuration of this
parameter must be consistent with the actual physical connection. Otherwise,
the board may not work properly.

Interval for requesting the bandwidth for the secondary link when the system is
not in congestion state
Bandwidth requested each time for the secondary link when the system is not
in congestion state

Whether to enable each AC RRU external alarm port's customer definition


switch.
"0" indicates that the external alarm port's customer definition switch is
disabled and
this port is not defined by customor but by vendor, and "1" indicates that the
external
alarm port's customer definition switch is enabled.
It does not take effect to DC RRU, whose external alarm ports are always
defined by customer.

The destination signaling point (DSP) of the adjacent BSC must be an Iur-g DSP.

Whether to adjust the BTS offset manually or automatically

Mode of dynamically adjusting the EGPRS uplink encoding scheme.


Value 0 indicates dynamic adjustment of EGPRS uplink coding scheme is not
supported;
value 1 indicates that the uplink coding scheme is adjusted according to
downlink quality measurements reported by MS;
value 2 indicates that the uplink coding scheme is adjusted according to uplink
quality measurements reported by BTS.

This parameter specifies whether to enable automatic auto-loading and autoactivation of the BTS software. If this parameter is set to Yes, the BTS software
is automatically loaded and activated when the BTS is initialized or a board is
added; the TMU software is automatically loaded and activated when the BTS is
initialized or BSC starts checking res. If this parameter is set to Yes, the BTS
software fails to be forcibly loaded and activated. If this parameter is set to No,
the BTS software can be successfully forcibly loaded and activated.

This parameter specifies the automatic load mode of the BTS software. If this
parameter is set to common download, common loading is performed on the
OML/EML, and the link is not extended. If this parameter is set to quick
download(without traffic), quick loading can be performed on the dynamically
extended link besides the OML/EML. This may affect the services in the cell. If
this parameter is set to quick download(reserve BCCH Trx traffic), quick loading
can be performed on the dynamically extended link besides the OML/EML. This
should not affect the services on the main BCCH TRX of the cell.

Administrative state of a cell

Administrative state of the TRX

Administrative state of the channel

End time for adjusting the offset time


Cell load threshold for adjusting the offset time. If the load threshold is
exceeded, the offset time is not adjusted.

Offset Time Adjustment Switch

Start time for adjusting the offset time

Advanced alarm management rule type

This parameter specifies the software version 1 that is automatically loaded


and activated. The version of the BTS software stored on the OMU must be
consistent with this version number. Otherwise, a software version
inconsistency alarm is reported. An example of the version format is as follows:
BTS3000V100R008C11SPC003.
This parameter can be set to only a BTS software version or a cold patch
version. You can use either of the following methods to query the version
number of the BTS software or the cold patch.
Method 1: If the BTS software or the cold patch is downloaded to the OMU
through the MML command DLD BTSSW, you can run the MML command LST
BTSSW to obtain the number of the version to be loaded according to the
returned result.
Method 2: If the BTS software version or the cold patch is not downloaded to
the OMU, you can decompress the BTS software package or cold patch
package. Then, check the vercfg.xml file in the level-1 directory of the
compressed package. The value after the label "SoftwareVersion" is the
software version.

This parameter specifies the software version 2 that is automatically loaded


and activated. The BTS software stored on the OMU must be consistent with
this version number. Otherwise, the software version inconsistency alarm may
be reported. An example of the version format is as follows:
BTS3000V100R008C11SPC003.
This parameter can be set to only a BTS software version or a cold patch
version. You can use either of the following methods to query the version
number of the BTS software or the cold patch.
Method 1: If the BTS software or the cold patch is downloaded to the OMU
through the MML command DLD BTSSW, you can run the MML command LST
BTSSW to obtain the number of the version to be loaded according to the
returned result.
Method 2: If the BTS software version or the cold patch is not downloaded to
the OMU, you can decompress the BTS software package or cold patch
package. Then, check the vercfg.xml file in the level-1 directory of the
compressed package. The value after the label "SoftwareVersion" is the
software version.

If the echo path is traced, the echo is judged and controlled according to the
trace result of the echo path parameters. Otherwise, the echo is judged and
controlled according to the recommended value.
This parameter is used for echo judgment and control when the echo
parameters are not traced.
If the local input voltage is lower than the value of this parameter and the
remote end transmits the voice signal, the AEC function uses the comfort noise
to replace the minor echo. In this case, the speech signals at low level may also
be cut.
Extra delay due to the transmission line. This parameter should be set
according to the actual conditions and is applicable to satellite transmission.
This parameter is used to determine whether there are speech signals at the
local end. If the local SNR is lower than the value of this parameter, echo
control is not performed.
This parameter indicates whether the acoustic echo cancellation (AEC)
functional switch is on or off.

Threshold for detecting the AEC performance

Time for detecting the AEC performance

Counter for radio link failures during an AMR full rate call. See the description of
"Radio Link Timeout" in "SET GCELLCCBASIC".

Number of SACCH multiframes during an AMR full rate call. See the description
of "SACCH Multi-Frames" in "SET GCELLCCBASIC".
GPS receiver ID
GPS receiver type.

Counter for radio link failures during an AMR half rate call. See the description
of "Radio Link Timeout" in "SET GCELLCCBASIC".

Number of SACCH multiframes during an AMR half rate call. See the description
of "SACCH Multi-Frames" in "SET GCELLCCBASIC".

Alarm ID

Alarm ID

Identifier of the alarm. This parameter uniquely identifies an alarm.

Identifier of the alarm. This parameter uniquely identifies an alarm.

Identifier of the alarm. This parameter uniquely identifies an alarm.

Alarm ID

Alarm ID

Delay time for mutual-aid detection on a cell after the cell is initialized. When
the cell initialization has just finished, the cell is in an unstable state. Mutualaid detection at this time may cause a wrong decision. Therefore, this
parameter is used for specifying proper delay.

Type of alarm selection

Alarm selection mode


Whether to trace A-interface messages during end-to-end user tracing. The
end-to-end tracing is conducted throughout the network. The A-interface
tracing results can be obtained from the MSC or BSC.

Whether to allow flow control for the location update services during the A
interface flow control
whether to allow flow control for the mobile-originated services during the A
interface flow control
Whether to allow flow control for the mobile-terminated services during the A
interface flow control
Whether to allow flow control for the other services including emergency call,
call re-establish, and LMU services during the A interface flow control
Whether to enable the A interface flow control mechanism in the BSC6900

Flow control method used by the BSC6900. Flow control method at the Abis
interface: When receiving a channel request message, the BSC6900 begins flow
control on the call according to the flow control level of the A interface. Flow
control method at the A interface: When establishing an SCCP connection, the
BSC6900 begins flow control according to the flow control level of the A
interface and releases part of the call.

Rate of discarded services in level 1 of the A interface flow control

Rate of discarded services in level 2 of the A interface flow control

Rate of discarded services in level 3 of the A interface flow control

Rate of discarded services in level 4 of the A interface flow control

Rate of discarded services in level 5 of the A interface flow control

Rate of discarded services in level 6 of the A interface flow control


CSD(Circuit Switched Data) service redundancy level, which is configured to
decrease the data loss rate during transmission in A over IP mode.

Fixed gain value in fixed gain mode

Target level in fixed level mode


This parameter restrains the maximum gain to the input signal. It is valid only
when "ALC Mode" is "FIXEDLEVEL" or "ADAPTIVE". If the parameter is set to a
small value, it may affect the conformance to the target level.
Maximum target level in adaptive ALC mode

Mimumum target level in adaptive ALC mode

ALC level control mode

Whether to enable the adaptive level control (ALC) function


Retry times after the timer for the reply from the peer expires during the NSVC
live test. If the reply is not received after the system resends the message
according to retry times, the NSVC is regarded as faulty.
Duration of the timer to wait for the reply from the peer during the NSVC live
test

Specifies the bandwidth occupied when the " transmission resource group type
" is IP and the " bandwidth mode " is HALF_DUPLEX.

Whether to reassign the TBF for a different Trx


When this parameter is set to ON, the GMM/SM signaling service is assigned
only one PDCH; otherwise, the GMM/SM signaling service is assigned one or
more PDCHs as required.
Maximum ratio of the number of AMR half rate channels to the total number of
channels in a cell. When the resource allocation principle is determined by the
BSC, no AMR half rate channel can be further assigned if the ratio of the
number of AMR half rate channels to the total number of channels in the cell is
greater than or equal to the value of this parameter. When the resource
allocation principle is not determined by the BSC, radio resource allocation does
not depend on the setting of this parameter.
Total number of channels = number of half rate channels + number of full rate
channels x 2
Whether to allow EDA multiplex. "Not Allow": the TBF of the EDA cannot be
multiplexed with other TBR; "Allow": the TBF of the EDA can be multiplexed
with other TBF.
Number of allowed measure report missed. If the number of allowed measure
report missed exceeds this value, the previous measure report is invalid.
Maximum ratio of the number of half rate channels to the total number of
channels in a cell. When the resource allocation principle is determined by the
BSC, no half rate channel can be further assigned if the ratio of the number of
half rate channels to the total number of channels in the cell is greater than or
equal to the value of this parameter. When the resource allocation principle is
not determined by the BSC, radio resource allocation does not depend on the
setting of this parameter.
Total number of channels = number of half rate channels + number of full rate
channels x 2
Value ALLCIC indicates that all E1/T1 timeslots on the A interface must be set
with the start CIC. Value ALLNULL indicates that all E1/T1 timeslots on the A
interface can be set with the value NULL.
Value ALLCIC indicates that all E1/T1 timeslots on the PB interface must be set
with the start CIC. Value ALLNULL indicates that all E1/T1 timeslots on the PB
interface can be set with the value NULL.
If the feed current of the TMA on tributary 0 is smaller than the value of this
parameter, the TMA Low Temperature alarm is triggered.
If the feed current of the TMA on tributary 1 is smaller than the value of this
parameter, the TMA Low Temperature alarm is triggered.

If the feed current of the TMA on tributary 2 is smaller than the value of this
parameter, the TMA Low Temperature alarm is triggered.
If the feed current of the TMA on tributary 3 is smaller than the value of this
parameter, the TMA Low Temperature alarm is triggered.
If the feed current of the TMA on tributary 4 is smaller than the value of this
parameter, the TMA Low Temperature alarm is triggered.
If the feed current of the TMA on tributary 5 is smaller than the value of this
parameter, the TMA Low Temperature alarm is triggered.
Accumulated alarm clearance failure duration.Threshold for the accumulated
duration in which the alarm persists. If the accumulated duration exceeds this
threshold, an alarm is cleared. Otherwise, the alarm persists.
Whether the configuration of alarm parameters is allowed.
In multi-mode scenario, the value of this parameter must be the same as the
value of the parameter in other modes.
ID of the intermittent alarm.

Alarm ID
If the input current of the antenna feeder is smaller than the value of this
parameter, an alarm related to the GPS antenna is reported.
If the input current of the antenna feeder is greater than the value of this
parameter and "GPS or RGPS" is set to "GPS", an alarm related to the GPS
antenna is reported.
If the input current of the antenna feeder is greater than the value of this
parameter and "GPS or RGPS" is set to "RGPS", an alarm related to the RGPS
antenna is reported.
Accumulated alarm occurrence duration.Threshold for the accumulated
duration in which the alarm persists. If the accumulated duration exceeds this
threshold, an alarm is generated. Otherwise, no alarm is generated.

Alarm Occur Accumulative Time refers to the percentage of the alarm


occurrence accumulative time to "Flash Statis Alarm Raise Time Window". If the
alarm occurrence accumulative duration is greater than the parameter value,
the BTS fault statistical alarm is reported. For example, if the parameter value
is 60, it indicates that Alarm Occur Accumulative Time = "Flash Statis Alarm
Raise Time Window" x 60%. If the parameter value is 0, no statistics is
collected.
Alarm Clear Accumulative Time refers to the percentage of the alarm clearance
accumulative time to "Flash Statis Alarm Clear Time Window". If the alarm
clearance accumulative duration is greater than this threshold, the BTS fault
statistical alarm is cleared. For example, if the parameter value is 30, it
indicates that Alarm Clear Accumulative Time = "Flash Statis Alarm Clear Time
Window" x 30%. If the parameter value is 0, no statistics is collected.
If the number of alarm flashes exceeds the value of this parameter within the
time specified by "Flash Statis Alarm Raise Time Window", the BTS Statistical
Alarm is generated. If this parameter is set to 0, the statistics of the BTS alarm
flashes is not collected.
If the number of alarm flashes is smaller than the value of this parameter within
the time specified by "Flash Statis Alarm Clear Time Window", the BTS
Statistical Alarm is cleared. If this parameter is set to 0, the statistics of the BTS
alarm flashes is not collected.
Whether the configuration of alarm parameters is allowed. The value "YES"
indicates that the configuration is allowed, and the value "NO" indicates that
the configuration is not allowed.
Type of the alarm. The alarm can be a fault alarm or an event alarm.

It is used to perform open loop power control. Alpha parameter is used by the
MS to calculate the output power PCH of the uplink PDCH. This parameter is
used to set the reduced class of the Tx power of the MS, in correspondence
with the path loss, when the GPRS dynamic power control is enabled.

Decimal part of the antenna altitude


Height of the specified GSP receiver antenna
Integer part of the antenna altitude
Height of the specified GSP receiver antenna

Alarm severity. One or more severities can be selected. By default, all severities
are selected.

Alarm severity. One or more severities can be selected. By default, all severities
are selected.

Whether to supply power to the TMA on tributary 0

Whether to supply power to the TMA on tributary 1

Whether to supply power to the TMA on tributary 2

Whether to supply power to the TMA on tributary 3

Whether to supply power to the TMA on tributary 4

Whether to supply power to the TMA on tributary 5

Maximum degree by which the BSC can control the power of the AMR BTS
dynamically

Whether to enable the III power control algorithm for AMR calls. If enabled,
power control is performed on AMR calls.

Whether to enable the adaptive adjustment function of AMR downlink


threshold. After this function is enabled, the BTS estimates the long-term voice
quality (indicated by the long-term FER(frame erase ratio)) and compares the
estimated result with the specified target voice quality. If the estimated result
does not conform to the target voice quality, it indicates that the current AMR
handover threshold may not be the best for the current radio conditions. In this
case, the BSC6900 adjust threshold adaptively according to the relation
between the estimated voice quality and the target voice quality.

Number of measurement reports sampled for averaging downlink AMR signal


strength. A single measurement report may not reflect the actual network
situations accurately. Therefore, the BSC needs to average the measured values
in several successive measurement reports to reflect the radio environment.

Number of downlink AMR measurement reports that the BSC predicts. The BSC
takes a while to confirm the power control effect of a power control command.
Thus, the BSC makes a power control decision based on a measurement report
that lags behind the changes in the receive level and quality instead of
reflecting the real-time radio environment. As a result, the power control is late.
To prevent late power control to a certain degree, the power control algorithm
involves a measurement report prediction filter. The BSC can sample several
downlink measurement reports in a short time and filter them according to a
specific weight to predict future N measurement reports.
This parameter specifies the number N.

Quality level threshold for decreasing downlink AMR signal power. If the BTS
transmits AMR signals at a quality level less than "AMR DL Qual. Upper
Threshold", the BSC decreases the power of the BTS. If (downlink receive level "AMR MAX Down Adj. PC Value by Qual.") < "AMR DL RX_LEV Lower Threshold",
the BSC does not adjust the transmit power.

Quality level threshold for increasing downlink AMR signal power. If the BTS
transmits AMR signals at a quality level greater than "AMR DL Qual. Lower
Threshold", the BSC increases the power of the BTS. If (downlink receive level +
"AMR MAX Up Adj. PC Value by Qual.") > "AMR DL RX_LEV Upper Threshold",
the BSC does not adjust the transmit power.

Number of measurement reports sampled for averaging downlink AMR signal


quality. A single measurement report may not reflect the actual network
situations accurately. Therefore, the BSC needs to average the measured values
in several successive measurement reports to reflect the radio environment.
During downlink power control, if the downlink receive quality level is equal to
or greater than this threshold, "AMR DL RX_LEV Upper Threshold" is increased
by "AMR DL Qual Bad UpLEVDiff" to further increase the expected downlink
power level.

During downlink power control, if the downlink receive quality level is equal to
or greater than "AMR DL Qual Bad Trig Threshold", "AMR DL RX_LEV Upper
Threshold" is increased by "AMR DL Qual Bad UpLEVDiff" to further increase the
expected downlink power level.
Upper threshold for downlink AMR signal strength.
If the downlink received AMR signal level is greater than this threshold, a power
decrease is computed. Then, the power is decreased by the least of the power
decrease, maximum power adjustment step allowed by the quality zone to
which the received signal quality belongs, and "AMR MAX Down Adj. PC Value
by Qual.".
Power decrease = downlink received signal level - ("AMR DL RX_LEV Upper
Threshold" + "AMR DL RX_LEV Lower Threshold")/2
The maximum power adjustment step allowed by the quality zone is chosen
from "AMR MAX Down Adj. Value Qual. Zone 0", "AMR MAX Down Adj. Value
Qual. Zone 1", and "AMR MAX Down Adj. Value Qual. Zone 2" according to the
quality zone.

Lower threshold for downlink AMR signal strength.


If the downlink received AMR signal level is less than this threshold, a power
increase is computed. Then, the power is increased by the least of the power
increase, "AMR MAX Up Adj. PC Value by RX_LEV", and "AMR MAX Up Adj. PC
Value by Qual.".
Power increase = ("AMR DL RX_LEV Upper Threshold" + "AMR DL RX_LEV Lower
Threshold")/2 - downlink received signal level.

Whether to enable the algorithm for the load-based AMR handover between full
rate and half rate

With "F-H Ho Period" and the duration for triggering handover from full rate to
half rate, this parameter determines the current ATCB offset by which to choose
the MSs to undergo handover from full rate to half rate.
ATCB offset = (duration for triggering handover from full rate to half rate/"F-H
Ho Period" + 1) x "AMR F-H Ho ATCB Adjust Step"

ATCB threshold for the AMR handover from full rate to half rate. If the ATCB of
an AMR full rate call is equal to or greater than this threshold, the AMR call is
handed over from full rate to half rate.

With "F-H Ho Period" and the duration for triggering handover from full rate to
half rate, this parameter determines the current path loss offset by which to
choose the MSs to undergo handover from full rate to half rate.
Path loss offset = (duration for triggering handover from full rate to half rate/"FH Ho Period" + 1) x "AMR F-H Ho Pathloss Adjust Step"

Path loss threshold for the AMR handover from full rate to half rate. If the path
loss of an AMR full rate call is equal to or less than this threshold, the AMR call
is handed over from full rate to half rate.

Quality threshold for the AMR handover from full rate to half rate. If the uplink
and downlink receive quality levels of an AMR full rate call are equal to or less
than this threshold, the AMR call is handed over from full rate to half rate.

Load threshold for the AMR handover from full rate to half rate. If the cell load
is greater than this threshold, the AMR full rate calls are handed over to half
rate.

ATCB threshold for the AMR handover from half rate to full rate. If the ATCB of
an AMR half rate call is less than this threshold, the AMR call is handed over
from half rate to full rate.

Path loss threshold for the AMR handover from half rate to full rate. If the path
loss of an AMR half rate call is greater than this threshold, the AMR call is
handed over from half rate to full rate.

Whether to enable the algorithm for the uplink and downlink receive quality
based AMR handover from half rate to full rate

Quality threshold for the AMR handover from half rate to full rate. If the receive
quality level of an AMR half rate call is greater than this threshold, the AMR call
is handed over from half rate to full rate.

Load threshold for the AMR handover from half rate to full rate. If the cell load
is less than this threshold, the AMR half rate calls are handed over to full rate.

Maximum step by which the power can be increased according to received


signal quality

Maximum step by which the power can be decreased when the received signal
quality belongs to quality zone 0.
Huawei power control algorithm generation II classifies the received signal
quality into three quality zones. The maximum step by which the power can be
decreased according to signal level varies according to the quality zones.
Maximum step by which the power can be decreased when the received signal
quality belongs to quality zone 1.
Huawei power control algorithm generation II classifies the received signal
quality into three quality zones. The maximum step by which the power can be
decreased according to signal level varies according to the quality zones.
Maximum step by which the power can be decreased when the received signal
quality belongs to quality zone 2.
Huawei power control algorithm generation II classifies the received signal
quality into three quality zones. The maximum step by which the power can be
decreased according to signal level varies according to the quality zones.

Maximum step by which the power can be increased according to received


signal level

Whether to enable the compensation of AMR measurement reports in Huawei


power control algorithm generation II
If this parameter is set to YES, Huawei power control algorithm generation II
puts a currently received measurement report into the measurement report
compensation queue. Then, the algorithm records the change in the transmit
power based on the MS/BTS power in the measurement report. According to the
power change, the algorithm compensates the received signal level in a history
measurement report after measurement report interpolation.
Before making a power control decision, the BSC samples and weights the
received signal level and quality in several history measurement reports. The
MS/BTS transmit power may vary over these measurement reports. To ensure
the accuracy of the received signal level and quality to be weighted, the power
control algorithm needs to compensate the received signal level and quality in
the history measurement reports where the transmit power differs from the
current transmit power.

Minimum interval between two consecutive AMR power control commands

Maximum step by which the power can be decreased according to received


signal quality
Number of levels by which the BTS increases the power of an SACCH frame.
This parameter is used for SACCH power control. When sending an SACCH
frame, the BTS increases the power of the SACCH frame by this specified
number of levels.
Whether to enable the BSC to assign AMR half rate channels preferentially
according to the channel types allowed by the MSC and the current TCH seizure
ratio of the cell
Load threshold for assigning half rate channels preferentially. If the current TCH
seizure ratio of the cell is greater than this threshold, AMR half rate channels
are assigned preferentially.

Whether to enable the adaptive adjustment function of AMR uplink threshold.


After this function is enabled, the BTS estimates the long-term voice quality
(indicated by the long-term FER(frame erase rate)) and compares the
estimated result with the specified target voice quality. If the estimated result
does not conform to the target voice quality, it indicates that the current AMR
handover threshold may not be the best for the current radio conditions. In this
case, the BSC uses the relevant algorithm to adjust the adaptive threshold
according to the relation between the estimated voice quality and the target
voice quality.

Number of measurement reports sampled for averaging uplink AMR signal


strength. A single measurement report may not reflect the actual network
situations accurately. Therefore, the BSC needs to average the measured values
in several successive measurement reports to reflect the radio environment.

Number of uplink AMR measurement reports that the BSC predicts. The BSC
takes a while to confirm the power control effect of a power control command.
Thus, the BSC makes a power control decision based on a measurement report
that lags behind the changes in the receive level and quality instead of
reflecting the real-time radio environment. As a result, the power control is late.
To prevent late power control to a certain degree, the power control algorithm
involves a measurement report prediction filter. The BSC can sample several
downlink measurement reports in a short time and then weigh them to predict
future N measurement reports.
This parameter specifies the number N.

Quality level threshold for decreasing the power of an uplink AMR call. If the MS
transmits AMR signals at a quality level less than "AMR ULQual. Upper
Threshold", the BTS decreases the power of the MS. If (uplink receive level "AMR MAX Down Adj. PC Value by Qual.") < "AMR UL RX_LEV Lower Threshold",
the BTS does not adjust the transmit power.

Quality level threshold for increasing the power of an uplink AMR call. If the MS
transmits AMR signals at a quality level greater than "AMR UL Qual. Lower
Threshold", the BTS increases the power of the MS. If (uplink receive level +
"AMR MAX Up Adj. PC Value by Qual.") > "AMR UL RX_LEV Upper Threshold",
the BTS does not adjust the transmit power.

Number of measurement reports sampled for averaging uplink AMR signal


quality. A single measurement report may not reflect the actual network
situations accurately. Therefore, the BSC needs to average the measured values
in several successive measurement reports to reflect the radio environment.
During uplink power control, if the uplink receive quality level is equal to or
greater than this threshold, "AMR UL RX_LEV Upper Threshold" is increased by
"AMR UL Qual. Bad UpLEVDiff" to further increase the expected uplink power
level.
During uplink power control, if the uplink receive quality level is equal to or
greater than "AMR UL Qual. Bad Trig Threshold", "AMR UL RX_LEV Upper
Threshold" is increased by "AMR UL Qual. Bad UpLEVDiff" to further increase
the expected uplink power level.

Upper threshold for uplink AMR signal strength


If the uplink received AMR signal level is greater than this threshold, a power
decrease is computed. Then, the power is decreased by the least of the power
decrease, maximum power adjustment step allowed by the quality zone to
which the received signal quality belongs, and "AMR MAX Down Adj. PC Value
by Qual.".
Power decrease = uplink received signal level - ("AMR UL RX_LEV Upper
Threshold" + "AMR UL RX_LEV Lower Threshold")/2
The maximum power adjustment step allowed by the quality zone is chosen
from "AMR MAX Down Adj. Value Qual. Zone 0", "AMR MAX Down Adj. Value
Qual. Zone 1", and "AMR MAX Down Adj. Value Qual. Zone 2" according to the
quality zone.

Lower threshold for uplink AMR signal strength.


If the uplink received AMR signal level is less than this threshold, a power
increase is computed. Then, the power is increased by the least of the power
increase, "AMR MAX Up Adj. PC Value by RX_LEV", and "AMR MAX Up Adj. PC
Value by Qual.".
Power increase = ("AMR UL RX_LEV Upper Threshold" + "AMR UL RX_LEV Lower
Threshold")/2 - uplink received signal level.
Maximum number of retransmissions of the A-interface circuit reset message.
When an A-interface circuit of the BSC is reset, the BSC sends the reset
message to the MSC and starts a timer. If the BSC fails to receive the Ainterface circuit reset response message from the MSC before the timer expires,
the BSC retransmits the A-interface circuit reset message. This parameter
specifies the maximum number of retransmissions of the A-interface circuit
reset message.
Maximum number of times of resending a reset message at the A interface.
When the BSC6900 is reset, the BSC6900 sends a reset message to the MSC
and starts a timer. If the timer expires when the BSC6900 waits for a response
message, the BSC6900 resends the reset message and restarts a timer. If the
timer expires again and the times of resending the reset message are less than
the value of this parameter, the BSC6900 continues resending the reset
message.
Maximum gain to the signals from the remote end. If the parameter is set to a
small value, the target SNR may be restrained when the signal arrives at the
local end.
Whether to enable the adaptive noise cancel (ANC) function
The system adjusts the remote input so that the ratio of the remote signal to
the local noise is above the value of this parameter.

Tilt angle of the RET antenna, it is accurate to one place of decimal, for
example, the tilt can be 7.7 degree.

Uniquely identifies an adjacent node

Adjacent node identifier of this IP path

New name of the alarm

ANR mode
This parameter determines the noise depression degree. A large absolute value
of this parameter corresponds to a strong depression.
ANR target noise level

Whether to enable the adaptive noise restrain (ANR) function

Size of the azimuth angle of the cell antenna


Length of the feeder cable. The GPS satellite card is connected to the antenna
through feeder cables. The transmission delay on the feeder cable can be
calculated on the basis of the length of the feeder cable, thus increasing the
timing accuracy of the satellite card.

Power supply switch of the GPS antenna feeder

E1T1 anti-error switch.

Whether to enable the BTS to clear the burglar alarm automatically

Number of the antenna

Antenna pass No. of the RXU of a sub-location group. The parameter is


configured only when the MRRU or GRRU is used in the sub-location group.
Number of the antenna feeder channel mapped to the RXU

Antenna pass number of the downlink tributary

Number of a port on the A interface board


Upper layer application type of the SCTP link. The upper layer application type
of A and LB interface is M3UA. In the BSC disaster tolerance, the application
type is BBAP in the case of the communication between the primary and
secondary BSC.
Application type of the semi-permanent link
Update frequency of the value N (packet drop interval), indicating that the
packet drop interval is updated after N packets are transmitted.
Upper length threshold of the TBF buffer queue. If the length of the TBF buffer
queue exceeds this threshold, whether the packets are discarded is determined
according to the packet discarding policy.
Congestion threshold of the TBF buffer queue. If the congestion level in the TBF
buffer queue exceeds this threshold, whether the packets are discarded
actively is determined according to the packet discarding policy.
Initial value of the interval (indicated by N) at which the packets in the TBF
buffer queue are discarded. The value N indicates the frequency of discarding
the packets in the TBF buffer queue. The greater the value N, the lower the
frequency of discarding packets, and the smaller the number of discarded
packets within a certain period. The smaller the value N, the greater the
number of discarded packets.

Lower threshold of the interval for discarding the packets in the TBF buffer
queue, that is, the minimum value of N (packet drop interval).
Upper threshold of the interval for discarding the packets in the TBF buffer
queue, that is, the maximum value of N (packet drop interval).
AQM switch

Target threshold of the TBF buffer queue

Local area code, for example, 021 for Shanghai

Area flag

Area flag

Threshold for reporting the recovery alarm for the abnormal release alarm. If
the percentage of the abnormal channel releases is equal to or less than this
threshold, the recovery alarm for the abnormal release alarm is reported. That
is, the abnormal release alarm is cleared.

Release statistics base for subchannels. This parameter indicates the number of
times that a subchannel is activated. In a timeslot, the release statistics base,
B, multiplied by the number of channels, N, is the channel release sum, S.
If the percentage of the abnormal channel releases in the latest S channel
releases exceeds the Abnormal Warn Threshold, the abnormal release alarm is
reported.
If the percentage of the abnormal channel releases in the latest S channel
releases is equal to or less than the Abnormal Release Threshold, the recovery
alarm for the abnormal release alarm is reported. That is, the abnormal release
alarm is cleared.
Threshold for reporting the abnormal release alarm. In a timeslot, the release
statistics base, B, multiplied by the number of channels, N, is the channel
release sum, S. If the percentage of the abnormal channel releases in the latest
S channel releases exceeds this threshold, the abnormal release alarm is
reported.

Retransmission times upon ARP timeout. When the ARP request times exceeds
the retransmission time without a response, the ARP/BFD detection failure
alarm is reported. This may trigger the port or board switchover.

ARP packet timeout time


Number of the slot where the A interface board is located
Number of the slot where the A interface board is located
Number of the subrack where the A interface board is located
Network management type of the alarm. By default, all network management
types are selected.

Network management type of the alarm. By default, all network management


types are selected.

Switch for assigning the channel of a better cell to the MS during MS access.

When this parameter is set to ENABLE, if the cell supports direct retry and the
current cell load is equal to or larger than the value of "Cell direct retry
forbidden threshold" in "SET GCELLOTHEXT" during the assignment, the
BSC6900 continues with the direct retry procedure. When this parameter is set
to DISABLE, the current call applies for channels in its own cells. If the
application fails, it continues with the direct retry procedure.

Offset relative to the level threshold for determining whether to assign a


channel in the overlaid subcell

Number of the cabinet where the associated RXU board is installed. This
parameter is valid for DRRU, MRRU, GRRU, or BTS3900E board in the remote
monitoring subrack of the DBS3036, DBS3900 GSM, or BTS3900E GSM. The
associated RXU board cannot be associated with other boards such as DEMU,
APMU, or DTCU.
Number of the cabinet where the associated RXU board is installed. This
parameter is valid for DRRU, MRRU, GRRU, or BTS3900E board in the remote
monitoring subrack of the DBS3036, DBS3900 GSM, or BTS3900E GSM. The
associated RXU board cannot be associated with other boards such as DEMU,
APMU, or DTCU.

Number of the slot where the associated RXU board is installed.

Number of the slot where the associated RXU board is installed.

Number of the subrack where the associated RXU board is installed.

Number of the subrack where the associated RXU board is installed.

Absolute level threshold for automatic optimization of neighbor cells and


frequencies. The measurement results in measurement reports are screened
and counted according to this threshold. If the signal strength of a neighbor cell
in a measurement report is greater than this threshold, the relevant traffic
statistics counter is incremented by one.
After the BSC6900 delivers an assignment command, the T3107 timer starts. If
the BSC6900 receives an assignment complete message within the scheduled
time, the T3107 timer stops. If the timer expires, the BSC6900 sends an
assignment failure message.

Timer for waiting for a single A-interface circuit blocking or unblocking answer.
The BSC6900 starts this T1 timer after sending a single A-interface circuit
blocking or unblocking message. If the BSC6900 does not receive a blocking or
unblocking answer from the MSC before this timer expires for the first time, the
BSC6900 resends the single A-interface circuit blocking or unblocking message
to the MSC. If the timer expires for the second time, the BSC6900 reports an
alarm for BSC circuit blocking or unblocking failure.
MSC reset protection timer, that is, interval between the time when the
BSC6900 receives an MSC reset message and the time when the BSC6900
answer to the MSC.
T17 timer. When receiving an MSC overload message or a single point
congestion message for the first time, the BSC6900 increases the level of the A
interface flow control and starts the T17 and T18 timers at the same time.
Timers T17 and T18 are set for adjusting the flow control level over the A
interface.
T18 timer. When receiving an MSC overload message or a single point
congestion message for the first time, the BSC6900 increases the level of the A
interface flow control and starts the T17 and T18 timers at the same time.
Timers T17 and T18 are set for adjusting the flow control level over the A
interface.

Timer for waiting for an A-interface circuit reset answer.


The BSC6900 starts this timer after sending an A-interface circuit reset
message. When this timer expires for the first time, the BSC6900 resends the
circuit reset message to the MSC. If this timer expires for the second time, the
BSC6900 reports an alarm for BSC circuit resetting failure.

Timer for waiting for an A-interface circuit group blocking or unblocking answer.
After sending a CIC group blocking/unblocking message over the A interface,
the BSC6900 starts the timer T20. If the BSC6900 fails to receive a response
from the MSC before the first expiry of T20, the BSC6900 resends the CIC group
blocking/unblocking message. If no response is received before the second
expiry of T20, the system reports the BSC Unable to Block Group Circuits or BSC
Unable to Unblock Group Circuits alarm.

Timer for waiting for an A-interface reset answer

Whether to enable the ATCB handover algorithm for the concentric cell.
According to the neighbor cell signal, the ATCB handover algorithm determines
the coverage of the overlaid subcell and balances the load between the
overlaid subcell, underlaid subcell, and neighbor cell. Therefore, the algorithm
helps to decrease the interference, to improve the conversation quality, and to
achieve aggressive frequency reuse in the overlaid subcell.

Hysteresis in the distance between the boundary of the overlaid subcell and the
boundary of the underlaid subcell. This parameter helps to adjust "Distance
Between Boudaries of Subcells" and thus to prevent ping-pong handover
between the overlaid and underlaid subcells. Assume that the signal strength of
the serving cell is SS(s) and that the signal strength of the neighbor cell is
SS(n). If SS(s) - SS(n) < "Distance Between Boudaries of Subcells" - "Distance
Hysteresis Between Boudaries", the MS is handed over from the overlaid
subcell to the underlaid subcell.

Distance between the boundary of the overlaid subcell and the boundary of the
underlaid subcell. This parameter specifies the difference between the
coverage of the overlaid subcell and the coverage of the underlaid subcell in
the concentric cell or dual-frequency network scenario. The boundaries of the
overlaid and underlaid subcells are determined according to the relative value
between the signal strength of the serving cell and the signal strength of the
neighbor cell. Assume that the signal strength of the serving cell is SS(s) and
that the signal strength of the neighbor cell is SS(n). If SS(s) = SS(n), the MS is
on the boundary of the underlaid subcell. If SS(s) - SS(n) > "Distance Between
Boudaries of Subcells", the MS is in the coverage of the overlaid subcell.
In the tight BCCH handover algorithm, this parameter specifies the difference
between the coverage of the TRX that carries the BCCH and the coverage of
the TRX that does not carry the BCCH. The relevant computation is the same as
the preceding computation.

Whether to enable the BSC to use a 8 kbit/s timeslot to transmit 8 kbit/s data at
the Ater interface

Whether to enable the BSC to assign half rate channels preferentially when the
Ater interface is congested

Threshold for considering the Ater interface, if congested, the BSC determines
whether to assign full or half rate channels preferentially according to the
congestion situations at the Ater interface. If the Ater resource usage exceeds
this parameter, the Ater interface is considered congested.

Index of an Ater connection path

Threshold for enabling the BSC local switching. When the congestion rate at the
Ater interface exceeds this threshold, the function is enabled.

Ater interface timeslot mask

Whether to configure the Ater OML link used for the TC subrack for the port. If it
is actually configured and you specify that it is not configured, the TC subrack
fails to start. If it is not configured and you specify that it is already configured,
crosstalk occurs on the timeslot over the port.

Ater maintenance link index


Ater connection path index,The index is set through the ADD ATERCONPATH
command.
Indentifies an Ater signaling channel
Transport mode of the Ater interface. The Ater interface can be in TDM or in IP
transport mode.
Number of the RF port on the RF front-end board of the BTS. The number is
unique in a board.

A interface timeslot mask

Attach-detach Allowed (ATT). If this parameter is set to YES, when an MS is


powered off, the network does not process any call connection for the MS as a
called party. In this way, the network processing time and resources are saved.
TMA attenuation factor of antenna tributary 1

TMA attenuation factor of antenna tributary 2

It specifies the loopback duration.

It specifies the test duration.

Validation mode of the PPP or MLPPP link negotiation

Validation mode of the PPP or MP link negotiation

Validation mode of the PPP or MP link negotiation

SSL authentication mode of the peer certificate

Username to validate, for the PPP or MLPPP link negotiation

Username to validate, for the PPP or MP link negotiation

Username to validate, for the PPP or MP link negotiation

Password to validate, upon PPP or MLPPP link negotiation

Password to validate, upon PPP or MP link negotiation

Password to validate, upon PPP or MP link negotiation

Type of the validation protocol for the PPP or MLPPP link negotiation

Type of validation protocol for the PPP or MP link negotiation

Type of validation protocol for the PPP or MP link negotiation

Whether the self-negotiation mode is adopted


1. When the FG2 board is used and the port type is GE, the self-negotiation
mode must be adopted.
2. If the self-negotiation mode is adopted, the FE port rate, working mode and
flow control mode must be in accordance with the negotiation result. If the selfnegotiation mode is not adopted, the FE port rate, working mode and flow
control mode must be specified. Make sure that the specified attributes are the
same as that of the peer. Otherwise, transmission failure must be incurred.
3. If the self-negotiation mode is adopted on the local system, the peer must
use the self-negotiation mode.

Whether inter-subrack path can be added automatically

Whether to allow automatic adjustment for the uplink threshold and hysteresis
of full rate AMR call rates
Whether to allow automatic adjustment for the uplink threshold and hysteresis
of half rate AMR call rates
Whether to enable the BSC to obtain BTS logs automatically

Whether to enable the auto-negotiation mode

The parameter specifies the work mode for the automatic download and
activation of the BTS software. BTS Software Auto DL and ACT indicates that the
BTS boards are downloaded and activated as required. TMU Software Auto ACT
indicates that only the TMU/DTMU/GTMU software is activated.

Auto unlock switch

Duration of time after which the locked user is unlocked automatically

optical adaptation type between high-order path and multiplex section.

Phase tag for GSM protocols supported by the A interface. The value of this
parameter is chosen according to the A interface phase tag provided by the
MSC.

Alarm level for a digital port

Alarm level. It is valid for the digital port.

Threshold of B1 and B2 signal degrade. This parameter specifies the generation


threshold and the recovery threshold of the B1B2 signal degradation threshold
in SDH frames at the optical port.

Threshold of B1 and B2 signal failure. This parameter specifies the generation


threshold and the recovery threshold of the B1B2 signal failure threshold in
SDH frames at the optical port.

Threshold of B3 signal degrade. This parameter specifies the generation


threshold and the recovery threshold of the B3 signal degradation threshold in
SDH frames at the optical port.

Threshold of B3 signal failure. This parameter specifies the generation


threshold and the recovery threshold of the B3 signal failure threshold in SDH
frames at the optical port.

Switch of backplane LINE1

Switch of backplane LINE2

Path (complete path) of the backup file

Directory for saving the backup file

Quality threshold for determining that a call is disconnected because of poor


quality. If the uplink quality or downlink quality in the measurement reports
during the period of "Timer for Bad Quality DISC Statistic" is higher than the
value of this parameter before the call is disconnected, you can infer that the
call disconnection is due to poor quality. This parameter can be used to
calculate the number of call disconnections due to poor quality.
Whether the downlink TBF can be established in advance. Downlink TBF
establishment in advance indicates that the downlink TBF is established
immediately after the MS establishes the uplink TBF rather than establishing
the downlink TBF after the SGSN sends the data block.
Bar code 2 of the interface board of the BTS. This parameter is the electronic
serial number of the standby PTU board. An electronic serial number uniquely
identifies an PTU board. This parameter is set before delivery.
IP address of the backup port

Mask of the backup port

This parameter specifies the method of saving the BTS backup power.
When this parameter is set to "Turn off TRX", the BSC preferentially shuts down
some TRXs when the BTS experiences a power failure. When this parameter is
set to "Reduce Backup Power", the BSC saves the power according to the
configured "Backup Power Saving Policy" when the BTS experiences a power
failure.

This parameter specifies the backup power saving policy of the BTS.
When this parameter is set to "Cover Priority", the BTS shuts down some TRXs,
waits for a certain period of time, and then decreases the power of the BCCH
TRX. When this parameter is set to "Capability Priority", the BTS decreases the
power of the BCCH TRX, waits for a certain period of time, and then shuts down
some TRXs. When this parameter is set to "Saving Priority", the BTS shuts down
some TRXs and meanwhile decreases the power of the BCCH TRX.

Whether the cells at the 1900 frequency support high frequency 1900

Whether the cells at the 850 frequency support high frequency 1900

Whether the cells at the 900 frequency support high frequency 1900
Duration in which intra-cell handover is forbidden after the number of
consecutive intra-cell handovers reaches the maximum. Intra-cell handover can
be conducted again only after this duration.
List of bar codes of all the cabinets in the BTS

The reference BTS must support the Um interface software synchronization.

Number of the temperature sensor corresponding to a battery group. You can


choose sensor 1 (Battery1Temp) or sensor 2 (Battery2Temp).
If you choose sensor 1, the system automatically uses sensor 1 to control the
temperature of the battery group and performs temperature compensation,
high temperature protection, and overtemperature alarm accordingly.
The system handling principles are the same if you choose sensor 2.
For the EPS4815 boards, this parameter can only be configured as
"Battery1Temp".
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Number of the temperature sensor corresponding to a battery group.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Battery capacity.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether the configuration of external battery is allowed. The value "YES"
indicates that the external battery can be configured, and the value "NO"
indicates that the external battery cannot be configured.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Allowed percentage of the battery discharging. After the AC power supply is cut
and the power of the battery is discharged by the value of this parameter, the
diesel engine is started to supply the power.

Battery type.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Number of the BBAP service listening port

Reference difference between uplink and downlink levels. This parameter works
with "Up Down Balance Floating Range" to count uplink-downlink imbalances.

Battery capacity. The battery capacity should be set according to the vendor
specification. If it is improperly configured, the battery life may be shortened.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Base station color code (BCC) of a cell, provided by the network planning
department. It is used for differentiating the neighboring cells using the same
BCCH frequency. A BCC and a network color code (NCC) compose a base station
identity code (BSIC).
Base station color code (BCC) of a cell, provided by the network planning
department. It is used for differentiating the neighboring cells using the same
BCCH frequency. A BCC and a network color code (NCC) compose a base station
identity code (BSIC).
BTS color code. It uniquely identifies different BTSs that are adjacent and use
the same TRX.
BCCH frequency of the cell

Frequency of the BCCH TRX

Frequency hopping mode of the TRX that carries the BCCH


Threshold for reporting the BC congestion alarm. When the BC congestion level
exceeds the threshold, the BC congestion alarm is reported.
Threshold for clearing the BC congestion alarm. When the BC congestion level
is below the threshold, the BC congestion alarm is cleared.

DSCP corresponding to the background service

Identifies one BC at the Gb interface board. The BCID's value range of PEUa
board is 0~255 and that of POUc board is 0~511.

Current limit coefficient of the battery. The maximum charging current equals
the value of "Battery Current Limiting Coefficient" multiplexed by "Battery
Capacity". If the charging current is 5 A higher than the maximum charging
current, the overcharge alarm is reported.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Boost-Charging Voltage. See the vendor specification for the setting of this
parameter.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether the configuration of external battery is allowed.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
ARP1 priority in the BE service. ARP1 priority weight determines the number of
the budget blocks and the block scheduling priority.
ARP2 priority in the BE service. ARP2 priority weight determines the number of
the budget blocks and the block scheduling priority.
ARP3 priority in the BE service. ARP3 priority weight determines the number of
the budget blocks and the block scheduling priority.
DSP bearer type.
MTP3: indicates that the lower layer bearer is the MTP3 used in ATM/TDM
scenario;
M3UA: indicates that the lower layer bearer is the M3UA used in IP scenario;
MTP3_M3UA: indicates that the lower layer bearer is the MTP3 and M3UA used
in ATM/TDM/IP scenario.
Time interval for sending a handshake message between BSC6900s. The
parameter checks whether the communication among BSCs in a redundancy
group is normal.

Average period for sending the measurement report over the EGPRS channel

Number of UTRAN TDD cells that should be included in measurement report

This parameter specifies whether to allow 3G better cell handover algorithm.

Whether to enable the algorithm for the handover to a better cell

According to the P/N rule, if the conditions for the handover to a better cell due
to interference are met for P seconds within N seconds, the handover is
triggered.
This parameter specifies the number P.

According to the P/N rule, if the conditions for the handover to a better cell due
to interference are met for P seconds within N seconds, the handover is
triggered.
This parameter specifies the number N.

Timeout times of the BFD packet. If several consecutive BFD packets are not
received, the BFD session is set to the DOWN state.
BFD Session No.

Allowed fluctuation of the difference between uplink and downlink levels


relative to the reference difference. If the difference between uplink and
downlink levels is outside the fluctuation range, the uplink and downlink are
considered imbalanced.
For example, assume that the Up Down Balance Basic Difference is set to 8 and
that the Up Down Balance Floating Range is set to 30. If the difference between
uplink and downlink levels is greater than 38 (= 8 + 30) or less than -22 (= 8 30), the uplink and downlink are considered imbalanced. If the difference
between uplink and downlink levels is between -22 and 38, the uplink and
downlink are considered balanced.

Mutual-aid changeback policy of baseband frequency hopping (FH). If multiple


TRXs in a baseband FH group are faulty and changeback is needed after mutual
aid of the baseband FH TRXs occurs: If you choose ALL, mutual-aid changeback
is implemented after all the TRXs in the FH group recover; if you choose PART,
as long as any of the faulty TRXs recovers, it is changed back at once and
added to the FH group.

Bit offset in the frame of the BTS clock

ARP1 priority in the Background service. ARP1 priority weight determines the
number of the budget blocks and the block scheduling priority.
ARP2 priority in the Background service. ARP2 priority weight determines the
number of the budget blocks and the block scheduling priority.
ARP3 priority in the Background service. ARP3 priority weight determines the
number of the budget blocks and the block scheduling priority.

Base Station Controller alarm blink filter switch

Alarm blink filter threshold. When the interval between the generation and
clearance of an alarm is equal to or smaller than the alarm blink filter threshold,
the alarm is filtered and not reported to the NMS.
Measurement period of filtered Base Station Controller alarms

Switch controlling whether to perform statistics of Base Station Controller


alarms

Retry times after the peer response timer expires during NSVC blocking

Duration of the peer response timer during NSVC blocking


Number of the port in the BM subrack where one end of the ATER connection
channel is located
Number of the slot in the BM subrack where one end of the ATER connection
channel is located
Number of the BM subrack where one end of the ATER connection channel is
located
Duration of the flow control protection timer enabled during the flow control
between the TCS and the MPS/EPS subracks

Whether to use the device IP address as the local IP address. When this
parameter is set to "YES", the device IP address is used as the local IP address
of the PPP link. When this parameter is set to "NO", the device IP address is not
used as the local IP address of the PPP link. In this case, you need to
reconfigure the local IP address of the PPP link.

Whether to report the alarm to the alarm box


Position of break point 1 in an RXU chain. The number of break points must not
be greater than the number of RXU boards in the RXU chain.
Position of break point 2 in an RXU chain. The number of break points must not
be greater than the number of RXU boards in the RXU chain.
Whether to enable the bad quality (BQ) handover algorithm. Whether to trigger
BQ handover depends on the uplink and downlink transmit quality (measured
by using BER). If the uplink or downlink BQ exceeds the BQ handover threshold,
emergency BQ handover is triggered. The possible causes of BER increase (or
quality degradation) include too low signal power and channel interference.

According to the P/N rule, if the conditions for emergency BQ handover are met
in P of N measurement reports, the handover is triggered.
This parameter specifies the number P.

If ("downlink level of the neighbor cell after filtering" - "downlink level of the
serving cell (after power control compensation)") > ("Inter-cell HO Hysteresis" "BQ HO Margin" + 64), the BQ handover to the neighbor cell is triggered.

According to the P/N rule, if the conditions for emergency BQ handover are met
in P of N measurement reports, the handover is triggered.
This parameter specifies the number N.

Classes of boards classified according to function modules

Classes of boards classified according to function modules

Classes of boards classified according to function modules

Classes of boards classified according to function modules

Number of the board

Number of the RF front-end board in the BTS


The upper threshold of the total receive bandwidth of all the TRXs bound to the
board, for example, when this value is 250, it means the the total receive
bandwidth should be no more than 25Mbits/s.

Software type of the BTS board

The upper threshold of the total send bandwidth of all the TRXs bound to send
pass of board, for example, when this value is 150, it means the the total send
bandwidth should be no more than 15Mbits/s.
Type of the board

Type of the board


Board type
Board type

Board type

Board type

Type of the new RXU board.

Type of the board. The type can be TMU/DTMU, DTRU, DPTU, QTRU, MRRU,
GRRU, BTS3900B, MRFU, GRFU, BTS3900E, DRFU, DRRU, UBRI or UTRP.

To avoid intermittent blinking, the switchover cannot be performed over a


certain period of time when the OML is disconnected. That period of time is
specified as ring II wait time before switch.

Contents of a cell broadcast message

Time interval for a cell broadcast message


Backup mode of the log. If "ENTIRE" is selected, all logs in the current database
are backed up. If "INCREMENTAL" is selected, the logs generated after last
backup are backed up.
BS-AG-BLKS-RES, indicating the number of the CCCH message blocks reserved
for the AGCH. After the CCCHs are configured, the value of this parameter
indicates the actual seizure rates of the AGCHs and the PCHs over the CCCHs.

DPC of the external BSC, which is used for inter-BSC communication. This
parameter can be represented in decimal, hexadecimal, and binary. By default,
this parameter is represented in decimal. To represent this parameter in
hexadecimal, precede this parameter value with H'. To represent this parameter
in binary, precede this parameter value with B'.
This parameter specifies whether to enable the TRX Intelligent Shutdown
feature.
It indicates whether the A interface E1/T1 is the primary BSC6900 or secondary
BSC6900.
Gateway IP address of the BSC6900. When the BSC provides the function of
simple cell broadcast, the BSC6900 sends cell broadcast messages through this
IP address defined by this parameter.
End time for collecting the inter-BSC offset information

Start time for collecting the inter-BSC offset information

Uniquely identifies a BSC in the TC pool

ID of the BSC that controls the external 2G neighbor cell

Period for fine tuning the BTS clock between BSCs

IP address of an interface board on the BSC6900 side

IP address of the BSC6900. If the connection mode of the BSC6900 and the CBC
is to lead cables out of the PIU, the value of this parameter must be the same
as the preset IP address of the PIU port.
If the connection mode is to lead cables out of the XPU panel, the value of this
parameter must be the same as the preset IP address of the XPU panel.
Conditions for enabling the function of BSC local switching.
UNCONDITIONALSTART: The function of BSC local switching is enabled without
restriction.
ATERCONGESTS: The function of BSC local switching is enabled when the
congestion rate of the Ater interface exceeds the value of "Ater Cong Thres for
BSC LocalSwitch".
PREFIXNUMBER: The function of BSC local switching is enabled when the
leading digits of the calling or called MSISDN are the preset value of "Prefix
Number for BSC (1-10)".
Unique name of the external BSC
Whether to allow high-priority calls to preempt the radio resources of lowpriority calls when radio resources are insufficient.
Whether to allow the call during an intra-BSC emergency handover to preempt
the radio resources of low-priority calls in the target cell.
In-BSC6900 port No. of the monitoring timeslot

Port number used for the communication between the BSC6900 and the CBC
Whether to allow the eMLPP priorities to be classified into two types: high
priority and normal priority.
If this parameter is set to YES, then during the resource preemption, the
priorities of all the services are compared, and the resources are assigned to
the services with a higher priority.
If this parameter is set to NO, then during the resource preemption, all the
services with an eMLPP priority greater than 2 are considered to have the same
priority, and the resources are assigned equally.

Whether to allow calls to queue for radio resources when radio resources are
insufficient.

Whether to allow the service during an intra-BSC emergency handover to


queue for radio resources in the target cell.
Reserved parameter 1 that is effective at the BSC level

Reserved parameter 10 that is effective at the BSC level

Reserved parameter 11 that is effective at the BSC level

Reserved parameter 12 that is effective at the BSC level

Reserved parameter 13 that is effective at the BSC level

Reserved parameter 14 that is effective at the BSC level

Reserved parameter 15 that is effective at the BSC level

Reserved parameter 16 that is effective at the BSC level

Reserved parameter 17 that is effective at the BSC level

Reserved parameter 18 that is effective at the BSC level

Reserved parameter 19 that is effective at the BSC level

Reserved parameter 2 that is effective at the BSC level

Reserved parameter 20 that is effective at the BSC level

Reserved parameter 21 that is effective at the BSC level

Reserved parameter 22 that is effective at the BSC level

Reserved parameter 23 that is effective at the BSC level

Reserved parameter 24 that is effective at the BSC level

Reserved parameter 25 that is effective at the BSC level

Reserved parameter 26 that is effective at the BSC level

Reserved parameter 27 that is effective at the BSC level

Reserved parameter 28 that is effective at the BSC level

Reserved parameter 29 that is effective at the BSC level

Reserved parameter 3 that is effective at the BSC level

Reserved parameter 4 that is effective at the BSC level

Reserved parameter 5 that is effective at the BSC level

Reserved parameter 6 that is effective at the BSC level

Reserved parameter 7 that is effective at the BSC level

Reserved parameter 8 that is effective at the BSC level

Reserved parameter 9 that is effective at the BSC level

In-BSC6900 slot No. of the monitoring timeslot

In-BSC6900 subrack No. of the monitoring timeslot

In-BSC6900 sub-timeslot No. of the monitoring timeslot. If the added monitoring


timeslot works at 64 kbit/s, the sub-timeslots are numbered from 0. If the
added monitoring timeslot works at 32 kbit/s, the sub-timeslots are numbered
from 0 or 4. If the added monitoring timeslot works at 16 kbit/s, the subtimeslots are numbered from 0, 2, 4, or 6. If the added monitoring timeslot
works at 8 kbit/s, the sub-timeslots are numbered from any value among 0 to 7.

When the BTS clock is adjusted, the offset is added to obtain better network
performance.

ID of the BSC at the other end of the link. In non-TC pool scenario, this
parameter specifies the ID of the primary BSC. In TC pool scenario, this
parameter specifies the ID of the BSC that is at the other end of the link.

ID of slave BSC in TC Pool

In-BSC6900 timeslot No. of the monitoring timeslot

This parameter is used to set the parameter BS_CV_MAX for MS countdown.


This parameter is used for the MS to calculate the CV. This parameter also
determines the duration of the timer T3198. When the MS sends one uplink RLC
data block, the receiving state of this data block is set to Pending and the timer
T3198 is started. If the MS receives the packet uplink acknowledge before the
timer T3198 expires, the MS updates the receiving state of each uplink RLC
data block according to the bit map in the message. If the timer T3198 of the
RLC data block in the Pending state expires, the MS sets the receiving state of
this data block to Nack and retransmits the data bloc.

Whether to enable the BTS to transfer BTS/MS power class to the BSC

Number of PAGCH blocks

Number of multiframes in a cycle on a paging sub-channel. In fact, this


parameter specifies the number of paging sub-channels that a paging channel
in a cell is divided into.
In an actual network, an MS does not listen to other paging sub-channels but its
belonging paging sub-channel only. Refer to GSM Rec. 05.02 and GSM Rec.
05.08. The larger the value of this parameter, the more the number of the
paging sub-channels in a cell, and the fewer the number of the users belonging
to each paging sub-channel. In this case, the mean uptime of the MS battery
can be prolonged. Refer to the computing mode of paging group in GSM 05.02
of GSM Standards. The larger the value of this parameter, however, the larger
the time delay of a paging message in a space segment. Thus, the average
service performance of the system lowers. Based on the principle of ensuring
that overload does not occur to paging channels, you must set this parameter
to a value as small as possible. You must regularly measure the overload
conditions of the paging channels in a running network and accordingly adjust
the value of this parameter properly. A paging message in a location area must
be sent in all the cells within this location area at the same time. Therefore, the
capacity of a paging channel of each cell in a location area must be the same or
nearly the same. The capacity refers to the calculated number of paging subchannels of each cell.

Number of PBCCH blocks

Number of PRACH blocks


General strategy of the BSS local switching, which includes the BSC local
switching and the BTS local switching. The two functions cannot be enabled at
the same time.

Type of the BSS local switching with the cooperation of the MSC.
NONSUPPORT: When performing local switching, the BSS need not determine
whether the MSC allows an MS to be involved in local switching.
BASIC: Assignment request messages and handover request messages sent by
the MSC contain a flag indicating whether to allow an MS for local switching.
The BSS must identify this flag when performing local switching.
ENHANCED: Assignment request messages and handover request messages
sent by the MSC contain a flag indicating whether to allow an MS for local
switching. The BSS must identify this flag when performing local switching. In
addition, when the BSS enables or stops local switching, the BSS sends a local
switching enabled or stopped message to the MSC.

Whether to support the paging function of the CS domain of the A interface.


Yes: the MS can be called upon paging request on the A interface when
handling the PS service; No: the MS cannot be called upon paging request on
the A interface when handling the PS service. This parameter is valid only when
the "A Interface Paging Co-ordination Switch" in "SET BSCPSSOFTPARA" is set to
"Open".
Type of the board

Type of the board

Type of the board

Board type

Board type
Board type
Board type
Board type
Board type

Board type

Type of the newly added antenna board

Type of the newly added board

Type of the newly added RXU board

Type of the board

Type of the board

Type of the board that controls the RET antenna.


1. DATU: It may represent the DATU or the DATM and is applicable to the
BTS3012, BTS3012AE, BTS3012_II, BTS3006C, and BTS3002E.
2. GATM: It is applicable to the BTS3900 GSM, BTS3900A GSM, BTS3036, and
BTS3036A.
3. RXU:DRRU,MRRU,MRFU,GRRU,GRFU,BTS3900E support the RET antenna
connect directly.
Identifies the BM subrack or TC subrack of the BSC.
When this parameter is set to "CFGBM", a BM signaling link is added.
When this parameter is set to "GFGTC", a TC signaling link is added.
The configuration flag specifies the operation is on the BM or TC.

This parameter specifies whether to enable the TRX Working Voltage


Adjustment feature. When this parameter is set to YES, the BSC6900 supports
the feature where the power amplifier can use different working voltages in
different TRX modulation modes.

Bard code of BTS BBU board.

Communication type of a BTS

Communication type of a BTS


Peer equipment type of the BTS. This parameter indicates whether to connect
the BTS to the BSC6900 or cascade the BTS to another BTS.
BTS detection switch. If the parameter is set to "CLOSE", the function of
detecting the BTS is disabled. If the parameter is set to "OPEN", the function of
detecting the BTS is enabled. When the function of detecting the BTS is
enabled, the BSC6900 performs addressing according to the BTS IP address and
sends the UDP packet carrying the VLANID to the BTS.
BTS index of the adjacent node to be added. The parameter is valid only when
Adjacent node type is set to Abis.

Index of the BTS, uniquely identifying a BTS in a BSC6900.

Index of the BTS running the command

Number of the BTS connected to the BSC. The number is unique in a BSC

List of BTS indexes. You can specify multiple BTSs,separated by "&" and "&&".
For example, "1&2&3&4&5" or "1&&5".

Index type of the BTS. BYNAME: query by BTS name; BYID: query by BTS index.

Whether to collect offset information by BTS index or BTS name

Base station index, 65535 indicate all base stations.

IP address of a BTS. When "BTS Com Type" is set to "LOGICIP", the value of the
parameter is the IP address of the BTS. When "BTS Com Type" is set to
"PORTIP", the value of the parameter is the IP address of the BTS ethernet port.
When "BTS Com Type" is set to "PPPLNK" or "MPGRP", the value of the
parameter is the local IP address of the BTS PPP link or BTS MLPPP group.
Conditions for enabling the function of BTS local switching.
UNCONDITIONALSTART: The function of BTS local switching is enabled without
restriction.
ABISCONGESTS: The function of BTS local switching is enabled when the
congestion rate of the Abis interface exceeds the value of "Abis Cong Thres for
BTS LocalSwitch".
PREFIXNUMBER: The function of BTS local switching is enabled when the
leading digits of the calling or called MSISDN are the preset value of "Prefix
Number for BTS (1-10)".
Subnet mask of BTS.

Whether to enable the BTS to preprocess measurement reports. This parameter


determines where to conduct power control.

Name of the BTS, uniquely identifying a BTS in a BSC6900. This parameter


cannot contain , ; = " ' more than two (include two) %, more than two (include
two) space, more than three (include three) +.

Connect BSC BTS Name.It is unique in one BSC.This parameter cannot contain ?
| : < > " @ # ! % ^ & * . [ ] / \ \\ '.

List of BTS names. You can specify multiple BTSs, separated by "&". For
example, "Name1&Name2".

If the parameter is set to "ON", all the Ping packets are sent.
If the parameter is set to "OFF", all the Ping packets are discarded.

This parameter specifies whether the BSC is allowed to shut down the BCCH
TRX that is configured as "Shut Down Enabled" to save power after the BSC
receives a power failure message from the BTS.
When this parameter is set to Yes, the BSC shuts down all the TRXs that are
configured as "Shut Down Enabled", including the BCCH TRX, after receiving a
power failure message from the BTS. When this parameter is set to No, the BSC
shuts down only the non-BCCH TRXs that are configured as "Shut Down
Enabled" after receiving a power failure message from the BTS.

Maximum degree by which the BSC can control the power of the BTS
dynamically
Whether to specify "Power Control threshold Adjust for SAIC" in the MML
command "SET GCELLPWR3"
Software version number of the BTS

Transmission compression ratio of a BTS. 1. Modifying the settings of "Transfers


Compress Rate" may change the bandwidth required by the BTS. That is, the
current bandwidth may be excessive or insufficient. If the bandwidth is
insufficient, more secondary links should be added or timeslots should be
rearranged. 2. The greater the "Transfers Compress Rate" is, the smaller the
compression rate is and the greater the required bandwidth is. 3. The user can
get the actual value through multiplying the value of this parameter by 0.01.
The default value of this parameter is 100, which means no compression.

Type of the BTS

Type of the BTS

Type of the BTS

Time for which the BTS waits to restore a BFD session

Type of TRX loopback test


Battery type.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

If the OML is not established at one port after a period of time, the OML
switches to another port and tries to connect to this port. That period of time is
called ring II rotating duration time.

Whether to enable the data binding function

Identifies a unique PTP BVC with NSE


The BSSGP virtual connection identifier. It is used to identify multiple BVCs that
multiplexes the NS-VC.
Duration of BVC flow control timer F. A cell sends the flow control message at
the interval specified by this timer.

Switch for adjusting the dynamical bandwidth of the logical port. If this switch is
turned on, the system adjusts the dynamical bandwidth of the logical port
according to the transmission quality of the link monitored by the IPPM. After
this switch is turned on, the IPPM function must be activated on the IPPATH of
this logical port. For details about the IPPM, see the description of the command
"ACT IPPM".
If the available backward bandwidth is less than or equal to this value, the
backward congestion alarm is emitted and backward congestion control is
striggered.
If the available backward bandwidth is greater than this value, the backward
congestion alarm is cleared and backward congestion control is stopped.
If the ratio of available backward bandwidth is greater than this value, the
backward congestion alarm is cleared and backward congestion control is
stopped.
If the ratio of available backward bandwidth is less than or equal to this value,
the backward congestion alarm is emitted and backward congestion control is
triggered.
If the available backward bandwidth is greater than this value, the backward
overload congestion alarm is cleared and backward overload control is stopped.
If the ratio of available backward bandwidth is greater than this value, the
backward overload congestion alarm is cleared and backward overload control
is stopped.
If the available backward bandwidth is less than or equal to this value, the
backward overload congestion alarm is emitted and backward overload control
is triggerd.
If the ratio of available backward bandwidth is less than or equal to this value,
the backward overload congestion alarm is emitted and backward overload
control is triggered.
Ratio of reserved backward bandwidth for handover user
Reserved backward bandwidth for handover user
Maximum ratio of the estimated bottleneck bandwidth

Bandwidth mode
Threshold of bandwidth change based on the load control algorithm. When the
system detects that the change of the available bandwidth exceeds this
threshold through the IPPM, the system starts adjusting the bandwidth of the
logical port.

Threshold for reporting the uplink-downlink imbalance alarm. If the percentage


of the uplink-downlink imbalance measurement reports in the total valid
measurement reports is equal to or greater than this threshold, the uplinkdownlink imbalance alarm is reported.
Index type. The value can be BYIDX or BYNAME.

Whether the reselection hysteresis parameter is applied to the C31 criterion


Whether GPRS cell reselection offset is used for C32 calculation during cell
reselection. If this parameter is set to 1, then only the positive hysteresis of the
neighoring cell is used in C32 calculation.
Descriptive information of the BTS cabinet

List of all the cabinet numbers in the BTS


Whether the added cabinet is a remote cabinet

Whether to allow call re-establishment. Burst interference or blind spots due to


high buildings may lead to a radio link failure. If a call drop is caused by such a
failure, the MS can start call re-establishment to resume the conversation.

Calibration value of the clock

Whether an MS uses the calculated value as the final receive level value. The
calculated receive level value is the measured receive level value minus the
receive level value obtained from the BCCH TRX timeslots. This parameter is a
cell option in system messages 3 and 6.
Whether to enable the capacity and coverage of the BTS to be automatically
optimized according to the actual situation of the incumbent network.

Card Frequency Attribute


Whether to indicate that the IP Path is carried on the IP logic port or resource
group. NULL indicate the IP Path is carried on the physics port.
Bearer type of the logical port
Port type of the SBFD/ARP bearer

Used together with "Cell Bar Qualify" to decide the priority status of a cell.
Refer to GSM Rec. 04.08.
Cell Bar Qualify Cell Bar Access Cell selection priority Cell reselection priority
NO
NO
Normal
Normal
NO
YES
Prohibited
Prohibited
YES
NO
Low
Normal
YES
YES
Low
Normal

Uniquely identifying a cell broadcast center (CBC)


IP address of a CBC

CBC interface parameter. The value of this parameter must be translated into a
binary numeral. The following describe each bit of the value:
Bit 0: phase flag
Bit 1: message type flag
Bit 2: cell list flag
Bit 3: whether to carry a recovery indication
Bit 4: whether to carry a cell ID
Bit 5: whether to carry a recovery indication during resetting

Port number at the CBC side in the communication with the BSC6900

Duration of no cell broadcast message at the Cb interface. If the BSC6900 does


not receive any message from the CBC during the preset value of this
parameter, the BSC6900 considers that the connection with the CBC has been
broken and reestablishes a connection.

Used together with "Cell Bar Access" to decide the priority status of a cell. See
GSM Rec. 0408. This parameter does not affect cell reselection but cell
selection only.
Cell Bar Qualify Cell Bar Access Cell selection priority Cell reselection priority
NO
NO
Normal
Normal
NO
YES
Prohibited
Prohibited
YES
NO
Low
Normal
YES
YES
Low
Normal

Maximum burst size (MBS)


Timer interval for sending handshake messages. According to the value of this
parameter, the BSC6900 regularly sends the CBC a handshake message to
decide whether the communication between the BSC6900 and the CBC is
normal.
Number of enhanced measurement reports (EMRs) sampled for averaging the
CV_BEP on the SDCCH. Averaging the CV_BEP in multiple EMRs helps to prevent
the incomprehensiveness of a single EMR.
Number of enhanced measurement reports (EMRs) sampled for averaging the
CV_BEP on the TCH. Averaging the CV_BEP in multiple EMRs helps to prevent
the incomprehensiveness of a single EMR.
Country code, for example, 86 for China
Whether to enable the certificate chain
DISABLE: indicating that the certificate chain is disabled
ENABLE: indicating that the certificate chain is enabled

Time interval for sending overload messages, used for the BTS to notify the
BSC6900 of the load over a specific CCCH timeslot. See GSM Rec. 0508.

This parameter is used by the BTS to inform the BSC of the load on a CCCH
timeslot, that is, the load of the access requests on the RACH and the load of all
the messages (such as paging messages and packet immediate assignment
messages) on the PCH. For details, see GSM Rec. 08.58. If the load on a CCCH
timeslot exceeds the value of this parameter, the BTS periodically sends the
CCCH overload message to the BSC. The interval for sending the CCCH
overload message is "CCCH Load Indication Period".

DSCP corresponding to the session service


Transmission period of the CCM packet in the MA
Threshold of forbidding directed retry for cells. When the value of "Assignment
Cell Load Judge Enable" in "SET GCELLCCBASIC" is ENABLE, if cells support
directed retry and the current cell load is greater than or equal to the value of
this parameter, the BSC allocates a channel to an MS through the process of
directed retry.

Offset of the measurement report of the cells at the 1800 MHz frequency.
Before cells are sequenced by priority, according to frequencies, the value of
this parameter must be added to the receive level value in the measurement
report of the cells at the 1800 MHz frequency.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
7: 42 dB

Threshold of the measurement report of the cells at the 1800 MHz frequency.
When the receive level value in the measurement report of the cells at the
1800 MHz frequency exceeds the value of this parameter, the report takes
effect. After being filtered, the measurement report is used for priority
sequencing of cells.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
6: 36 dB
7: positive infinity

BCCH frequency of a 2G neighbor cell that MSs can measure in idle mode.
Recording the BCCH frequencies of 2G neighbor cells that MSs can measure in
idle mode, the BA1 table is sent in System Information 2, 2bis, and 2ter.

Whether to generate the 2G BA1 table automatically according to neighbor cell


relations or to input the 2G BA1 table manually. Recording the BCCH
frequencies of 2G neighbor cells that MSs can measure in idle mode, the BA1
table is sent in System Information 2, 2bis, and 2ter.
BCCH frequency of a 2G neighbor cell that MSs can measure in dedicated
mode. Recording the BCCH frequencies of 2G neighbor cells that MSs can
measure in dedicated mode, the BA2 table is sent in System Information 5,
5bis, and 5ter.
This parameter indicate whether to generate the 2G BA2 table automatically
according to neighbor cell relations or to input the 2G BA2 table manually.
Recording the BCCH frequencies of 2G neighbor cells that MSs can measure in
dedicated mode, the BA2 table is sent in System Information 5, 5bis, and 5ter.
Timeslot power attenuation level of the EDGE TRX in 8PSK. The attenuation
level ranges from 0 to 50, each of which corresponds to an attenuation of 0.2
dB.
When the EDGE TRX sends signals in 8PSK, the transmit power must be lower
than the mean power in GMSK.
Offset applied to the receive level of a GSM900 cell in the measurement report
before prioritizing cells by frequency bands. Before cells are sequenced by
priority, according to frequencies, the value of this parameter must be added to
the receive level value in the measurement report of the cells at the 900 MHz
frequency.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
7: 42 dB

Threshold of the measurement report of the cells at the 900 MHz frequency.
The measurement report is valid only when the receive level in the
measurement report of the GSM900 cell exceeds this threshold. After being
filtered, the measurement report is used for prioritizing the cells. The value 7
means infinite:
0: 0 dB
1: 6 dB
...
6: 36 dB
7: positive infinity
Whether the cell can be added to the reselected candidate cell list. If this
parameter is set to "NoPermit", the cell cannot be reselected as the candidate
cell for handover. If this parameter is set to "Permit", the cell can be reselected
as the candidate cell for handover.

If the coverage type of a cell is outdoor coverage, the BTS detects whether the
standing wave alarm is generated only when the forward power is greater than
35 dBm.
If the coverage type of a cell is indoor coverage, the BTS detects whether the
standing wave radio alarm is generated only when the forward power is greater
than 30 dBm.

Even charging voltage of the battery. The battery is charged at the voltage as
specified by this parameter.

Even charging voltage of the battery. The battery is charged at the voltage as
specified by this parameter.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Float charging voltage of the battery. The battery is charged at the voltage as
specified by this parameter.
Float charging voltage of the battery. The battery is charged at the voltage as
specified by this parameter.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Index of a cell, uniquely identifying a cell in a BSC6900

ID of the cell. The cell ID cannot conflict with other cell IDs in the BSC.

Index of a cell, uniquely identifying a cell in a BSC6900

Index of a cell, uniquely identifying a cell in a BSC6900

Index of a cell, uniquely identifying a cell in a BSC

Cell Index

List of the user-defined neighbor cells to be measured. This parameter is


represented as a character string where the IDs of the cells to be measured are
separated by &, such as 1&2&5.
The BSC supports up to 50 cells.
Index type of a cell when this command is executed

Index type of the cell

Index type of the cell. BYNAME: query by cell name; BYID: query by cell index.
This parameter specifies whether a cell is the OL subcell or the UL subcell. This
parameter is applied to the enhanced dualband cell.
Layer of the cell. If the layer of the cell is lower, it is more likely that a handover
to the cell will be triggered.
List of cell indexes. All cell indexes are combined as a character string,
separated by "&". For example, 1&2&5.
Whether an assignment complete message contains a cell list.
According to GSM Rec. 08.08, during a channel assignment, an assignment
complete message contains a cell list only when the cell of the MS changes.
For the MSCs of some vendors, however, assignment complete messages must
contain cell lists. To meet such a requirement, the value of this parameter must
be YES.
Maximum number of SDCCHs in the cell. Before converting a TCH into an
SDCCH, the BSC compares the number of SDCCHs after the conversion in the
cell with "Cell SDCCH Channel Maximum". If the number of SDCCHs after the
conversion in the cell exceeds this parameter, the BSC does not convert the
TCH into an SDCCH.

Name of a cell, uniquely identifying a cell in a BSC6900

Name of a cell, uniquely identifying a cell in a BSC

Name of a cell, uniquely identifying a cell in a BSC6900

List of cell names. All cell names are combined as a character string, separated
by "&". For example, cell1&cell2&cell5. The cell name should not contain the
following characters:
? | : < > " @ # ! % ^ & * . [ ] / \ \\ '

Power of each passage on the MRRU in the cell. When multiple operators are
configured on an MRRU, the parameter specifies the power of each operator on
the MRRU.

Threshold of the downlink receive level of an over-coverage cell. If the downlink


level of a cell is higher than the value of this parameter and the timing advance
(TA) is greater than the value of "Cell Over Coverage TA Threshold" in more
than 20% measurement reports, the cell is defined as an over-coverage cell.
Threshold of the TA of an over-coverage cell. If the downlink level of a cell is
higher than the value of this parameter and the timing advance (TA) is greater
than the value of "Cell Over Coverage TA Threshold" in more than 20%
measurement reports, the cell is defined as an over-coverage cell.
Maximum number of reported paging overload messages in the cell. If the BSC
allows the flow control on the re-paging messages, and the number of the
reported paging overload messages exceeds the value of this parameter, the
BSC determines that the cell is in PCH overload state.
Whether to allow the power-off of the battery.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Battery power-off voltage.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
This parameter specifies whether a 2G cell or 3G cell is selected in the inter-RAT
cell reselection procedure.
The number of times that the downlink transmission quality of the MS is lower
than the transmission quality threshold of the MS ("EDGE GMSK Quality
Threshold", "EDGE 8PSK Quality Threshold", or "GPRS Quality Threshold" by TBF
type) is calculated accumulatively. When the rate of the accumulated value to
the number of received measurement reports on the downlink transmission
quality (Packet Downlink Ack/Nack message) is greater than or equal to the
value of this parameter, the emergency reselection is triggered.
Information about the cell scenario. It needs to be sent to the BTS. Based on
the information, the BTS optimizes the allocation of resources.

This parameter specifies whether to allow a mobile phone to preferentially


camp on a 3G cell after a call is terminated in the areas covered by both the
GSM network and the UMTS network.

The BTS reports an alarm if the temperature of battery group 1 exceeds the
value of this parameter.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
The BTS reports an alarm if the temperature of battery group 1 is lower than
the value of this parameter.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Upper limit of the temperature measured by the temperature sensor of the
battery group 1. If the measured value is greater than the value of this
parameter, the value of this parameter is reported.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Lower limit of the temperature measured by the temperature sensor of the
battery group 1. If the measured value is smaller than the value of this
parameter, the value of this parameter is reported.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to allow the configuration of parameters related to the temperature
compensation of the battery group
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Threshold of the downlink receive level of an weak-coverage cell. If the
downlink level of a cell is lower than the value of this parameter and the timing
advance (TA) is smaller than the value of "Cell Weak Coverage TA Threshold" in
more than 30% measurement reports, the cell is defined as an weak-coverage
cell.

Threshold of the TA of an weak-coverage cell. If the downlink level of a cell is


lower than the value of this parameter and the timing advance (TA) is smaller
than the value of "Cell Weak Coverage TA Threshold" in more than 30%
measurement reports, the cell is defined as an weak-coverage cell.

Threshold for stopping LAPD link congestion control. This parameter cannot be
set too small. If this parameter is set too small, the congestion control duration
is too long, and thus the transmission capability of signaling links cannot be
fully used. The difference between the congestion start and end thresholds
cannot be too small. If the difference is too small, congestion control may be
started frequently on signaling links.

Name of the certificate chain file


Indicates whether the IP path is carried on the IP logic port or the resource
group.

Whether to allow the configuration of alarm parameters. The value "YES"


indicates that the configuration is allowed, and the value "NO" indicates that
the configuration is not allowed. If the parameter is set to "YES", all the other
parameters are reset to the default values in this command.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

BTS configuration modes include auto plan mode and normal mode.
In auto plan mode, the user can enable the auto planning algorithms and auto
optimization algorithms according to the BTS type. In normal mode, the auto
planning algorithms and auto optimization algorithms are disabled.

Configure switch.

Whether to enable the board parameters to be configured. If this parameter is


set to "YES", the user can set board parameters of the BTS cabinet. Otherwise,
the user cannot set the board parameters.
Whether to enable the board parameters to be configured. If this parameter is
set to "YES", the user can set the cabinet power type. Otherwise, the user
cannot set the cabinet power type.
Confirm password. The confirm password is required to ensure that a correct
password is entered.
Customized command group to be processed

This parameter is valid only when the operator belongs to the custom level.

Congestion end threshold. If the congestion end threshold is large, the


congestion control ends earlier. As a result, the congestion control effect is
poor. The work of the Ater signaling link is deteriorated.
Congestion end threshold. If the congestion end threshold is large, the
congestion control ends earlier. As a result, the congestion control effect is
poor. The work status of the Ater signaling link is deteriorated.
If the parameter is set to 1, it indicates that the CGI and RAC data is generated
through automatic planning. If the parameter is set to 0, it indicates that the
data needs to be manually entered.
Number of the cabinet group where the idle timeslot is located.

Name of the command group. You can define the name.

Congestion start threshold. If congestion start threshold is set to a large value,


there will be a time lag in the congestion control and the work of the signaling
link gets deteriorated. The interval between congestion start threshold and
congestion end threshold should not be too small. Otherwise, the work of the
signaling link is unstable. The congestion control will start frequently.

Congestion start threshold. If congestion start threshold is set to a large value,


there will be a time lag in the congestion control and the work of the signaling
link gets deteriorated. The interval between congestion start threshold and
congestion end threshold should not be too small. Otherwise, the work of the
signaling link is unstable. The congestion control will start frequently.
Congestion start threshold. If congestion start threshold is set to a large value,
there will be a time lag in the congestion control and, the work of the signaling
link gets deteriorated. The interval between congestion start threshold and
congestion end threshold should not be too small. Otherwise, the work of the
signaling link is unstable. The congestion control would start frequently.
This parameter indicates the geographical relationship between the
neighboring cell and the serving cell. In the BSC6900, if direction A is selected,
then the reverse direction is B.
Combination type of chains. "CHAINTORING" indicates that one chain changes
to a ring, and "COMBINECHAINS" indicates that two chains are combined into
one ring.
Channel assignment priority of the cell
If this parameter is set to CAPABILITY, the factors are listed as follows in a
descending order of priority: capacity factors, quality factors, PS cooperation
factors, and management factors.
If this parameter is set to QUALITY, the factors are listed as follows in a
descending order of priority: quality factors, capacity factors, PS cooperation
factors, and management factors.
If this parameter is set to PSRELATIVELY, the factors are listed as follows in a
descending order of priority: capacity factors, PS cooperation factors, quality
factors, and management factors.
If this parameter is set to PSABSOLUTELY, the factors are listed as follows in a
descending order of priority: PS cooperation factors, capacity factors, quality
factors, and management factors.
This parameter specifies the proportion of available PDCHs in a cell. When the
proportion of available PDCHs in the cell is lower than this threshold, the BSC
generates an alarm. When the proportion of available PDCHs in the cell is
higher than or equal to this threshold, the BSC generates a recovery alarm.
This parameter determines whether to activate the function of monitoring the
failure of logical channels in a cell. When this function is activated and the
proportion of faulty logical channels in the cell exceeds a predefined threshold,
the BSC generates an alarm.

This parameter specifies the proportion of available TCHs in a cell. When the
proportion of available TCHs in the cell is lower than this threshold, the BSC
generates an alarm. When the proportion of available TCHs in the cell is higher
than or equal to this threshold, the BSC generates a recovery alarm.
Channel number of a simple cell broadcast message. This is a key parameter
for adding a simple cell broadcast message. You can use "DSP GSMSCB" to
query and obtain the value of this parameter.
Whether to measure the channel interference during channel assignment. If
this parameter is set to NO, the BSC does not measure the channel interference
or send an interference indication during channel assignment. If this parameter
is set to YES, the BSC measures the channel interference during channel
assignment.
When the value of this parameter is YES, if the assignment request message
sent by the MSC contains the channel rate type indicating the support of both
full and half rates, and contains the speech version indicating the selection of
full rate speech version only or half rate speech version only, the BSC decodes
the channel rate type into the selection of full rate only or half rate only when
decoding the assignment request message.
This parameter is used to check whether the Abis timeslot for the PDCH is
faulty. When the out-of-synchronization period of the PDCH primary link
exceeds the value of this parameter, the Abis timeslot for the PDCH is regarded
as faulty.
Number of ping check timeouts. The parameter indicates the number of
timeout record failures.

Whether to enable the BSC to check automatically whether a BTS is connected


to a proper E1 port in the EIUa. If a BTS is connected to an E1 port configured
for another BTS in the EIUa, the BTS cannot be reset automatically after the
BTS is initialized. Thus, the data configurations on the BTS side differ from the
data configurations on the BSC side.

Alarm mode of the ANT_A tributary of an RXU board. There are three alarm
modes. Alarm mode 1 has only one type of alarms. The alarm current is fixed
and greater than the normal working current.
Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The
alarm current is fixed and greater than the normal working current.
Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The
warning alarm current is periodical pulse current, while the critical alarm
current is fixed.
When the parameter is set to 1, "ANT_A ALD Current Minor Alarm Occur Th",
"ANT_A ALD Current Minor Alarm Clear Th", "A ALD Cur-Minor Alarm Over-Cur
Duration", and "A ALD Cur-Minor Alarm N-Cur Duration" cannot be configured.
When the parameter is set to 2, "A ALD Cur-Minor Alarm Over-Cur Duration",
and "A ALD Cur-Minor Alarm N-Cur Duration" cannot be configured. When the
parameter is set to 3, "ANT_A ALD Current Minor Alarm Occur Th", and "ANT_A
ALD Current Minor Alarm Clear Th" cannot be configured.

Alarm mode of the ANT_B tributary of an RXU board. There are three alarm
modes. Alarm mode 1 has only one type of alarms. The alarm current is fixed
and greater than the normal working current.
Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The
alarm current is fixed and greater than the normal working current.
Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The
warning alarm current is periodical pulse current, while the critical alarm
current is fixed.
When the parameter is set to 1, "ANT_B ALD Current Minor Alarm Occur Th",
"ANT_B ALD Current Minor Alarm Clear Th", "B ALD Cur-Minor Alarm Over-Cur
Duration", and "B ALD Cur-Minor Alarm N-Cur Duration" cannot be configured.
When the parameter is set to 2, "B ALD Cur-Minor Alarm Over-Cur Duration",
and "B ALD Cur-Minor Alarm N-Cur Duration" cannot be configured. When the
parameter is set to 3, "ANT_B ALD Current Minor Alarm Occur Th", and "ANT_B
ALD Current Minor Alarm Clear Th" cannot be configured.

Detection index. The index is a unique value ranging from 0 to 511 if it is not
specified.
Detection index
Total number of times that the BTS checks whether to switch off the air
conditioner
Total number of times that the BTS checks whether to switch on the air
conditioner

Whether to perform checksum when receiving message

Whether to perform checksum when sending message

Checksum arithmetic type. According to the RFC4960, the ALDER32 algorithm


is not applicable to the SCTP checksum. The CRC32 is recommended.
Type of the detection that is performed between the BSC and the gateway.
Duration

Number of the channel in the TRX

Timeslot for playing sound

Number of the channel in the TRX

Type of channel loopback test

Channel type of the timeslot on the TRX. The channel type of timeslot 0 must
not be set, because the combined BCCH is configured by default. The channel
type of other timeslots can be set to full-rate TCH or half-rate TCH.

Whether an assignment complete message contains the information element of


Chosen Channel

Whether a handover perform message contains the information element of


Chosen Channel

Whether an HO REQ ACK message contains the information element of Chosen


Channel

Whether an encryption complete message contains the information element of


Chosen Encryption Algorithm
Whether a handover performed message contains the information element of
Chosen Encryption Algorithm

Whether an assignment complete message contains the information element of


Chosen Encryption Algorithm

Whether an HO REQ ACK message contains the information element of Chosen


Encryption Algorithm

Whether to allow a multi-density TRX board, that uses the dynamic power
sharing algorithm to assign channels, to assign a channel to an MS when the
remaining power on the multi-density TRX board is less than the power required
by the MS. If this parameter is set to YES, a multi-density TRX board that uses
the dynamic power sharing algorithm to assign channels cannot assign a
channel to an MS when the remaining power on the multi-density TRX board is
less than the power required by the MS.If this parameter is set to NO, a multidensity TRX board that uses the dynamic power sharing algorithm to assign
channels can assign a channel to an MS when the remaining power on the
multi-density TRX board is less than the power required by the MS.

This parameter indicates whether to collect CHR logs for a specified object.
Maximum number of allowable CS domain channel request messages within
the value of "CHAN REQ Statistical Period"
Average number of allowable PS domain channel request messages within the
value of "CHAN REQ Statistical Period"
Statistic period of the arrival rate of channel request messages. Within the
preset value of this parameter, the BSC6900 counts the number of channel
request messages. Once the current total number of times exceeds the value of
the allowable number of channel request messages of CPU0 within the statistic
period, the BSC begins to discard subsequent channel request messages until
the current time reaches a new "CHAN REQ Statistical Period".

Main BCCH+SDCCH/8+6TCH
Main BCCH+2SDCCH/8+5TCH
Main BCCH+SDCCH/8+extended BCCH (BCH)+5TCH
Main BCCH+SDCCH/8+extended BCCH (BCH)+TCH+extended BCCH (BCH)
+3TCH
The BCCHs in a cell need to be configured according to the number of channels
in the cell and the paging capacity in the location area.
The main and combined BCCHs shall always be configured in timeslot 0. An
extended BCCH can be configured only in timeslot 2, 4, or 6. If an extended
BCCH is configured, the CCCH parameter in the system message data needs to
be configured accordingly. For example, if an extended BCCH is configured in
timeslot 2, the CCCH parameter in the system message data needs to be
configured as two uncombined CCCHs.
To enable cell broadcast in a cell, add a CBCH to the cell during the radio
channel configuration. In the case of SDCCH/8 cell broadcast, set this
parameter to SDCCH_CBCH. You can change a TCH into SDCCH+CBCH or the
original SDCCH into SDCCH+CBCH. In the case of SDCCH/4 cell broadcast, set
this parameter to BCCH_CBCH. With the same effect, the SDCCH/8 and
SDCCH/4 cell broadcast services serve different network planning
requirements.
The data configurations for half-rate networking differ from the data
configurations for other networking.
In the case of half-rate networking, each TRX maintains high RSL traffic.
Therefore, the LAPD signaling link multiplexing ratio at the Abis interface is up

Identity code of a cell, A cell is a wireless coverage area identified by a base


station identity code and a global cell identification.
Can be input in hexadecimal format. The hexadecimal format is H'****, for
example, H'1214.

Cell identity code. The cell is a radio coverage area that is identified by the BTS
identity code and global cell identity code.

Indicates the A interface CIC. When operation mode is set to OPC index, DPC
group index, BSC ID, or CIC, the parameter is mandatory. The parameter
supports multiple values.
Indicates the Pb interface CIC. If the search object mode is set to search by the
specified No., the parameter is mandatory.
The parameter supports multiple values.
The TC DSP compares neighboring speech frame samples after the CIC
downlink one-way mute detection is enabled. When the number of times with
different results exceeds the value of this parameter, it is regarded that no oneway mute event occurs for the current call. Otherwise, it is regarded that a oneway mute event occurs for the current call.
This parameter indicates the period of completing a CIC downlink one-way
mute detection of each port.
This parameter determines whether the CIC downlink one-way mute detection
is enabled.
This parameter indicates the proportion of one-way mute CICs in all available
CICs over a port.
If one-way mute frames occur for the duration greater than "CIC Downlink OneWay Mute Detection Duration", then it is regarded that a one-way mute event
occurs for the current call.
Whether an assignment failure message contains the information element of
Circuit Pool
Whether an HO FAIL message contains the the information element of Circuit
Pool

Whether an assignment failure message contains the the information element


of Circuit Pool List

Whether an HO FAIL message contains the the information element of Circuit


Pool List

Whether an assignment complete message contains the information element of


Circuit Pool

Whether an HO REQ ACK message contains the information element of Circuit


Pool

Bandwidth of the logical port


This parameter specifies the estimated carrier-to-interference ratio of a new
call. It is used for the Huawei power control algorithm III to calculate the power
of the call.
Slot number of the BSC6900 board that is connecteds to the BTS

Subrack number of the BSC6900 board that is connected to the DXX

Whether the cell supports the MS with the DTM multi-timeslot capability of
class 11

Whether to enable the BSC to include the 3G classmark information element in


the Classmark Request message that the BSC forwards from the MSC to an MS

Error clear threshold.

Clock mode

Type of the clock protocol for the IP clock server

Type of the clock board

Clock mode of the BTS.


If this parameter is set to INT_CLK, the BTS does not track any external clock.
The internal high precision clock works in free-run mode.
If this parameter is set to TRCBSC_CLK, the BTS tracks the clock signals
received from the BSC.
If this parameter is set to EXCLK, the BTS tracks the clock signals received from
the external input clock.
If this parameter is set to IP_TIME, the BTS shakes hands through the IP network
with the IP clock server for synchronization.
If this parameter is set to IP_TRANSFER, the BTS extracts the clock from an E1
when there is not an IP clock after the BTS upgrades the transmission mode
from E1 transmission to IP transmission.
If this parameter is set to TRCGPS_CLK, the BTS extracts the clock through the
DGPS from the GPS.
If this parameter is set to UM_CLK, the BTS keeps pace with the signals
broadcast on the downlink main BCCH of a neighboring BTS.
If this parameter is set to PEER_CLK, the multimode BTS(GSM) keeps pace with
the signals that the other mode offer.

Delay for which the BTS waits to run the burglar alarm clearance command
after reporting the burglar alarm
Whether the alarm to be queried is cleared. You can select "cleared" or
"uncleared", or both of them. By default, both of them are selected.
Interval at which the BTS runs the burglar alarm clearance command
automatically
Name of the command to be queried. You can select one or more commands.

You can select one or more commands.

Sequence number of the command string of the scheduled subtask.


Number of the cabinet

Number of the cabinet

Number of the cabinet

Number of the cabinet where the port is located

Number of the cabinet

Number of the cabinet.


Time delay in the detection of core network interface failure. Within the preset
value of this parameter, the BSC6900 continuously detects core network
interface failures and then releases the management right of service objects.
Used to uniquely identify an MSC

Uniquely identifies a node of SGSN, with the specified operator name

Index of an MSC. It is used in storing and querying the MSC attributes

Index of the operator

Policy of the BSC6900 for judging whether the interface status of the core
network is normal. If the value is NONE, the BSC6900 does not change the
service management right. If the value is AINTFBLOCK, the BSC6900 releases
the service management right when detecting disconnection at the A interface.
Number of returned alarm records. By default, all records can be returned in
each query.
Type of the cabinet. The slot and subrack arrangements in a cabinet vary
according to the cabinet type.

Type of the BTS cabinet where the DMPU is installed

Maximum number of records allowed in the operation log

Assume that this threshold is not 0. When the accumulated number of alarm
blink times exceeds the threshold, the alarm is reported. For querying the alarm
blink measurement period, see "LST ALMBLKSW". For setting the alarm blink
measurement period, see "SET ALMBLKSW".

Assume that this threshold is not 0. When the number of alarm blink times is
smaller than the threshold, the alarm is reported. For querying the alarm blink
measurement period, see "LST ALMBLKSW". For setting the alarm blink
measurement period, see "SET ALMBLKSW".

Whether to adjust the candidate cell queue to give priority to intra-BSC/MSC


handover
Number of a simple cell broadcast message. You can run "DSP GSMSCB" to
query and obtain the information.
The value of this parameter cannot be 0.
This parameter, "Geography Scope", and "Update" uniquely decide a cell
broadcast message.
Whether to start the refrigeration equipment of the BTS.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to collect offset information by the BTS or cell

Combined loss used to estimate the downlink power during assignment

Level of common access control, used for load control, allowing or forbidding
the access of some users of common access levels

Complexity of the password

BTS compress rate.


Whether the BSC that controls the external cell and the local BSC belong to the
same MSC
Index type of the BTS connected to BSC
If the duration for buffering the data in queue 0 is less than or equals to the
value of this parameter, flow control is canceled.
If the duration for buffering the data in queue 1 is less than or equals to the
value of this parameter, flow control is canceled.
If the duration for buffering the data in queue 2 is less than or equals to the
value of this parameter, flow control is canceled.
If the duration for buffering the data in queue 3 is less than or equals to the
value of this parameter, flow control is canceled.
If the duration for buffering the data in queue 4 is less than or equals to the
value of this parameter, flow control is canceled.
If the duration for buffering the data in queue 5 is less than or equals to the
value of this parameter, flow control is canceled.
If the duration for buffering the data in queue 0 is more than or equals to the
value of this parameter, flow control is triggered.
If the duration for buffering the data in queue 1 is more than or equals to the
value of this parameter, flow control is triggered.
If the duration for buffering the data in queue 2 is more than or equals to the
value of this parameter, flow control is triggered.
If the duration for buffering the data in queue 3 is more than or equals to or
equals to the value of this parameter, flow control is triggered.
If the duration for buffering the data in queue 4 is more than or equals to the
value of this parameter, flow control is triggered.

If the duration for buffering the data in queue 5 is more than or equals to the
value of this parameter, flow control is triggered.
Whether to enable the concentric cell handover algorithm. The concentric cell
handover helps to achieve wide coverage in the underlaid subcell and
aggressive frequency reuse in the overlaid subcell and to improve the system
capacity and conversation quality. The concentric cell handover can be
classified into two types: handover from the underlaid subcell to the overlaid
subcell and handover from the overlaid subcell to the underlaid subcell.

Number of the port through which the DXX is connected to the BSC6900

Whether to connect the power monitoring board


Whether the Iur-g common connection is established between the BSC and a
co-BSC6900 RNC or an external RNC.
Type of the connection between the NE and EMS or LMT. The connection can be
a plain connection or SSL encryption connection.
Minimum interval between the two consecutive handover decisions of an MS.
The BSC cannot make a handover decision during the minimum interval.
To avoid frequent handover events in the cell, the BSC starts a timer after
delivering a handover command to an MS. The BSC allows the MS to make a
second handover decision only after the timer expires. This parameter specifies
the duration of the timer.

The twice intra-cell handover events during this interval are considered
consecutive handover events.

Whether to perform the PING operation continuously. When the continuous


PING operation is performed, the system sends the PING packets to the
specified IP address. You can stop the PING operation by using CTRL + Q.
Transmitted packets

Duration for starting the CPRI Loop test

This parameter specifies whether to allow the BSC6900 to enable or disable the
power amplifier of a TRX based on the traffic volume.

CPU number on a board

Whether to enable the BTS to support CRC4 check

Cell reselection hysteresis. This is one of the parameters used for deciding
whether to reselect cells in different location areas. This parameter can avoid
the increase of network signaling traffic due to frequent location update and
reduce the risk of losing paging messages.

Name of the certificate revocation list file


Whether to enable the certificate revocation list
DISABLE: indicating that the certificate revocation list is disabled
ENABLE: indicating that the certificate revocation list is enabled
Time interval for the BTS resending a channel release message

Number of times the BTS resends a channel release message

Cell Reselect Offset (CRO), indicating a correction of the C2.


Proper setting of this parameter can reduce the number of handover times,
helpful for assigning an MS to a better cell. In a special case that the PT is 31,
the larger the CRO value is, the lower the possibility of handing over an MS to
the cell.
Generally, do not set the CRO to a value larger than 25 dB. The CRO with a too
large value will cause uncertain states in a network. The CRO values of the cells
with different priorities in a network are almost the same. Refer to GSM Rec.
05.08 and GSM Rec. 04.08. The setting of this parameter affects only the MSs
supporting the protocol of GSM Phase 2 or a later version.

Threshold of the time for crosstalk detection. Within the threshold, if the call
flag continuously appearing in the code stream is different from the one saved
in a transcoder (TC) or a BTS, the TC or the BTS considers that a crosstalk
occurs and sends a message to the BSC6900. Upon receiving such a message,
the BSC6900 host board records in a log the information about the current call,
including the information about the Abis interface, Ater interface, BTS, cell,
TRX, channel, and TC. The crosstalk detection function helps locate the cause of
a crosstalk.

The field indicates whether the cross-connect path is available. When the crosspath is available, a maximum of four IP paths exists. The four IP paths are the IP
path between the first local IP address and the first peer IP address, the IP path
between the first local IP address and the second peer IP address, the IP path
between the second local IP address and the first peer IP address, and the IP
path between the second local IP address and the second peer IP address.
When the cross-path is unavailable, a maximum of two IP paths exists. The two
IP paths are the IP path between the first local IP address and the first peer IP
address and the IP path between the second local IP address and the second
peer IP address.

Output range of the supplementary information contained in the CHR in


common user mode. Multiple options can be selected at the same time.
Rate threshold of bad speech quality in common user mode.

Whether MR is contained in the CHRs in specified user mode


Whether the information about the specified abnormal call end is contained in
the CHRs in common user mode.

GSM CS data service downlink factor

CS data path

CS data priority

GSM CS data service uplink factor

Priority of the CS data service. The parameter is used for BSC6900 flow control.
The smaller the value of this parameter, the higher the priority.
Whether handover information is contained in the CHRs in common user mode
Whether the MR before call release is contained in the CHRs in common user
mode.
Whether the MR before handover is contained in the CHRs in common user
mode.
CHR output mode. In common user mode, the CHRs of all the MSs specified by
"CHR Output Range" are output. In specified user mode, the CHR of a specific
MS, which is specified by running the ADD GCSCHRUSER command, is output.
These two modes can co-exist and they do not affect each other.
Area in which CHRs need to be output in common user mode. If this parameter
is set to "Output All Records "in Cells, you need to run the SET GCSCHRSCOPE
command to specify the cells whose CHRs are to be output
Whether to output the call history record (CHR)

Type of signaling contained in CHRs

Threshold for starting LAPD link congestion control. This parameter cannot be
set too high. If this parameter is set too high, the signaling link may be
congested before congestion control is started. The congestion start and end
thresholds cannot be set too low. If they are set too low, congestion control may
be started frequently on the signaling link.

Type of the service whose CHR need to be output

GSM CS voice service downlink factor

Whether speech information is contained in the CHRs in specified user mode.

CS voice path

CS voice priority

GSM CS voice service uplink factor

Priority of a speech service in the CS domain. The parameter is used for


BSC6900 flow control.
The smaller the value of this parameter, the higher the priority.
Self-healing switch for the Ethernet adapter traffic monitoring

Timer alignment ready. Timer T1 is started after the MTP2 link enters the
Aligned Ready state. If one end of the MTP2 link receives an FISU or MSU
message from the peer end within the period of time defined by T1, the MTP2
link enters the In-service state. In other cases, T1 expires, and the MTP2 link is
considered as broken. This parameter only applies to the 64 kbit/s links. For the
2 Mbit/s links, the value of this timer is always 150000.

Timer not aligned. Timer T2 is started at the time that the MTP2 link is set up
and begins to transmit the SIO message. If one end of the MTP2 link receives
an SIO, SIN, or SIE message from the peer end with the period of time defined
by T2, the MTP2 link enters the next state. In other cases, T2 expires, and the
MTP2 link setup fails. This parameter only applies to the 64 kbit/s links. For the
2 Mbit/s links, the value of this timer is always 130000.

Timer aligned. Timer T3 is started at the time that the MTP2 link enters the
aligned state and starts to transmit SIN (normal alignment) or SIE (emergency
alignment) message. If one end of the MTP2 link receives an SIN or SIE
message from the peer end with the period of time defined by T3, the MTP2
link enters the next state. In other cases, T3 expires, and the MTP2 link setup
fails. This parameter only applies to the 64 kbit/s links. For the 2 Mbit/s links,
the value of this timer is always 1000.

Timer emergency proving. The two ends of the MTP2 link exchange messages
after entering the emergency verification state. Each end verifies the
correctness of the messages sent from the peer end. If the error rate of the
messages reaches the threshold specified by the protocol, the MTP2 link is
considered unavailable. The link verification can be performed for five times to
prevent the possibility of accidentally high error rate. If the error rate reaches
the specified threshold in all five verifications, the MTP2 link setup fails. This
parameter only applies to the 64 kbit/s links. For the 2 Mbit/s links, the value of
this timer is always 500.

Timer normal proving. The two ends of the MTP2 link exchange messages after
entering the normal verification state. Each end verifies the correctness of the
messages sent from the peer end. If the error rate of the messages reaches the
threshold specified by the protocol, the MTP2 link is considered unavailable.
The link verification can be performed for five times to prevent the possibility of
accidentally high error rate. If the error rate reaches the specified threshold in
all five verifications, the MTP2 link setup fails. This parameter only applies to
the 64 kbit/s links. For the 2 Mbit/s links, the value of this timer is always
30000.
Timer sending SIB. If one end of the MTP2 link detects congestion, it sends SIB
indications to the peer end at an interval specified by timer T5. This parameter
only applies to the 64 kbit/s links. For the 2 Mbit/s links, the value of this timer
is always 100.
Timer remote congestion. A link is considered broken when the remote
congestion duration exceeds the value specified by timer T6. This parameter
only applies to the 64 kbit/s links. For the 2 Mbit/s links, the value of this timer
is always 5000.
Timer excessive delay acknowledgement. A link is considered broken if one end
of the link does not receive a verification message from the peer end within the
period of time defined by timer T7 after sending a message. This parameter
only applies to the 64 kbit/s links. For the 2 Mbit/s links, the value of this timer
is always 2000.

Timer interval of resending FISU. Timer T9 specifies the interval at which the
BSC sends the FISU frames. That is, the BSC sends an FISU frame every N (N
indicates the period of time defined by T9) when the MTP2 link is idle. This
parameter only applies to the 64 kbit/s links. For the 2 Mbit/s links, the value of
this timer is always 10.
Critical threshold of CPU usage. When the CPU usage in "Fast judgement
window" reaches or exceeds the threshold, all active flow control functions are
implemented. Otherwise, the corresponding flow control mechanism is used.
Critical threshold of packet queue usage. When the packet queue usage
reaches or exceeds the threshold, all active flow control functions are
implemented.
DPC of the control BSC
Format of the control acknowledge message of the MS. Four access bursts are
used to obtain timing advance without sending polling message; RLC/MAC
control block is used to obtain timing advance after sending polling message.
Control Flag

Number of the cabinet which controls RET antenna.

ControlPort No. of RET antenna. The number of RET antenna which connect to
same feed tributary cannot be more than 6.For GATM boards, the valid value
ranges from 0 to 5. For RXU boards, the valid value ranges from 0 to 2.
Number of the slot where the board controlling the RET antenna is located. For
SingleRAN BTSs, the valid value ranges from 0 to 5. For non-SingleRAN BTSs,
the valid value ranges from 0 to 23.
Number of the subrack where the BTS board is located
Slot number of the MPU Subsystem for the centralized management of the
resources
Number of the BSC6900 slot where the XPU of the control plane is located

Number of the BSC6900 subrack where the XPU of the control plane is located

Configuration rollback control switch that is used to specify whether to support


the configuration rollback function
Whether an HO_RQD message contains the Current Channel

C-version number of the BTS software


Period of new file generation.
This is the data file for upgrading board. The data file names of different boards
are different.
Number of measurement reports sampled for averaging the signal quality on a
speech/data channel. Averaging the signal quality in multiple measurement
reports helps to avoid a sharp signal quality drop due to Rayleigh fading and to
ensure the comprehensiveness of a handover decision.
Number of measurement reports sampled for averaging the signal strength on
a speech/data channel. Averaging the signal strength in multiple measurement
reports helps to avoid a sharp signal level drop due to Rayleigh fading and to
ensure the comprehensiveness of a handover decision.

Data service supported by the BSC6900. You can set this parameter according
to actual requirements.

Date

Whether to limit the operation date of the operator


Unique number of the date range during which to disable the BSC from shutting
down the TRX dynamically
Date when the TMU board software is released

Temperature error allowed when the temperature control system adjusts the
temperature.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Whether the primary BCCH is configured on the inner or extra part of an


intelligent underlay-overlay (IUO) cell

Index of a same group cell in an enhanced dual band network

Name of a same group cell in an enhanced dual band network

Index type of a same group cell in an enhanced dual band network

DC Lowvoltage Alarm Cabinet No.

DC Lowvoltage Alarm Port No.

DC Lowvoltage Alarm Slot No.

DC Lowvoltage Alarm Subrack No.

DC voltage alarm lower threshold. When the busbar output voltage is lower
than the value of this parameter, an alarm indicating the abnormal busbar
voltage is reported.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

The BTS reports an alarm if the DC voltage exceeds the value of this parameter.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

The BTS reports an alarm if the DC voltage is lower than the value of this
parameter.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

DC voltage alarm upper threshold. When the busbar output voltage is higher
than the value of this parameter, an alarm indicating the abnormal busbar
voltage is reported.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
This parameter specifies the default pre-converted PDCHs in the dynamic
transferable channel pool.
When this parameter is greater than 0, three sub-links are bound to the static
PDCH and pre-converted PDCH in a cell by default.
The pre-converted PDCH can be preempted. You can set "Number of Reserved
Dynamic Channel" as required when you expect the pre-converted PDCH not to
be preempted.
Timer for delaying a connection release. This parameter is used for delaying the
channel deactivation after the active signaling link is broken. The purpose is to
reserve some time for the disconnection that may be repeated. After receiving
a REL IND message sent by the BTS, the BSC6900 starts the timer. When the
timer expires, the BSC6900 stops the timer and sends the BTS an RF CHAN REL
message.
The destination entity number uniquely identifies a destination entity.

Description of the operator account


Whether to start the anti-theft equipment of the BTS.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Destination IP address
Destination IP address
Destination IP address

Identifies a maintenance point in the maintenance group

Type of the object the BTS is connected to


Type of the object the BTS is connected to. Value range: BTS, BSC6900, and
DXX
Slot No. of the subsystem where the Iur-g common connection is established to
the co-BSC6900 RNC
Subrack No. of the subsystem where the Iur-g common connection is
established to the co-BSC6900 RNC
No. of the subsystem where the Iur-g common connection is established to the
co-BSC6900 RNC
ID of the TRX that carries the destination main BCCH
Interval for sending test TRAU frames in the period of class-2 mute
detection.Test TRAU frame is sent at the specified interval till the peer end
responds or the timer of "Period of Mute Detection Class 2" expires.
Maximum number of periods in which the local end does not receive BFD
packets from the peer end. If the number of periods in which the local end does
not receive BFD packets from the peer end reaches this parameter, the BTS
reports a BFD session fail.
Switch for Abis Timeslot Detection

Name of the RET antenna


Number of the RET antenna.
Device IP address of the interface board used by the PPP link.
Device IP Address Type

Downlink frequency of the external 3G cell

Number of the slot where the DFCB is installed

Number of the subrack where the DFCB is installed

The default DPC corresponds to the CN of the primary operator.


When only one DPC is configured, this parameter must be set to "YES",
indicating that all the calls for the operator are accessed through the CN
identified by the DPC.
When multiple DPCs are configured, this parameter also determines the DPC
that allows the generation of ESN. In this case, the parameter is set to "YES" for
this DPC while the value for other DPCs is "NO".
For the CN of a secondary operator, this parameter must be set to "YES" when
only one DPC is configured. This indicates that all the calls for the secondary
operator are accessed through the CN. When multiple DPCs are configured, this
parameter is invalid.
Whether to use the customized port
DEFAULTPORT: indicating that the FTP server uses the default port 21 as a
command port and port 20 as a data port to provide FTP services
CUSTOMPORT: indicating that the FTP server uses the customized port to
provide FTP services
Period for reporting differential GPS data

This parameter indicates the IP Address of DHCP Relay Gateway.


DHCP Relay ID
Whether to enable the diesel engine save switch

Whether to allow an MS to report the classmark and whether to hand over the
MS from the SDCCH in the frequency band for the main BCCH to the SDCCH in
a different frequency band according to the classmark

Day in the month on which the command can be executed.

Day in the week on which the command can be executed.

The relative path in the working path of the FTP user in the FTP server

Directory of the software to be downloaded

Whether the BSC sends an Assignment Fail message with the cause value of
directed retry to the MSC before the BSC initiates a directed retry procedure

Whether to enable a directed retry. The directed retry is to hand over an MS to


a neighboring cell in the same procedure as the handover. The directed retry is
an emergency measure applicable to abnormal traffic peaks in some areas of a
radio network. You should not use the directed retry as a major means of
solving traffic congestion. If the directed retry always occurs in some areas of a
network, consider adjusting the sector and TRX configuration and the network
layout.

Whether a cell is a repeater. With simpler functions than a BTS, a repeater is a


coverage extension device of a BTS. It is applied to widely-stretched areas or
indoor areas to solve the dead zone problem of BTS coverage. Using repeaters
cannot increase the traffic capacity of a network but improve the coverage only.
Because the BTS coverage increases, however, the total traffic improves
accordingly.
The setting of this parameter has effects on handovers. Repeaters use the
asynchronous transfer mode (ATM) due to a greater distance between them.
Therefore, handovers between repeaters are asynchronous. Synchronous
handovers will fail.

Timer to control the duration in which the BSC prevents the handover of an MS
from which the BSC receives the Disconnect message. If the MS is handed over
to a new cell after the MS sends the Disconnect message, the MS cannot
receive the Release Acknowledgement message from the original cell. Thus, the
MS cannot be disconnected. To protect from such a disconnection failure, the
BSC does not hand over the MS within the duration of this timer after the BSC
receives the Disconnect message from the MS.

Whether to activate transmit diversity on the common channel of a 3G cell

Delay of transmit diversity when 16QAM is used. Generally, the parameter is


applicable to general fading environments. The transmit diversity can generally
bring a gain of 3 dB to 5 dB. The fading conditions vary with the MS location;
therefore, MSs in a fixed time delay obtain different gains. In addition, the EDGE
service coding may be adversely affected. To avoid the preceding cases, the
delay of transmit diversity must be configurable and can be set for GMSK and
16QAM respectively. Only the double-transceiver BTSs and the distributed BTSs
can be configured with this parameter. For the BTSs of other types, this
parameter is set to an invalid value 255.

Delay of transmit diversity when 32QAM is used. Generally, the parameter is


applicable to general fading environments. The transmit diversity can generally
bring a gain of 3 dB to 5 dB. The fading conditions vary with the MS location;
therefore, MSs in a fixed time delay obtain different gains. In addition, the EDGE
service coding may be adversely affected. To avoid the preceding cases, the
delay of transmit diversity must be configurable and can be set for GMSK and
32QAM respectively. Only the double-transceiver BTSs and the distributed BTSs
can be configured with this parameter. For the BTSs of other types, this
parameter is set to an invalid value 255.

Delay of transmit diversity when 8PSK is used. Generally, the parameter is


applicable to general fading environments. The transmit diversity can generally
bring a gain of 3 dB to 5 dB. The fading conditions vary with the MS location;
therefore, MSs in a fixed time delay obtain different gains. In addition, the EDGE
service coding may be adversely affected. Therefore, the time delay of transmit
diversity must be configurable and can be separately set for GMSK and 8PSK.
Only the double-transceiver BTSs and the distributed BTSs can be configured
with this parameter. For the BTSs of other types, this parameter is set to an
invalid value 255.

Whether to support transmitting diversity or four diversity receiving

Minimum interval between two consecutive downlink power control commands

If the downlink receive quality level of an AMR full rate call is greater than this
parameter, the call needs to undergo Huawei power control generation III.

If the downlink receive quality level of an AMR full rate call is smaller than this
parameter, the call needs to undergo Huawei power control generation III.

If the downlink receive quality level of an AMR half rate call is greater than this
parameter, the call needs to undergo Huawei power control generation III.

If the downlink receive quality level of an AMR half rate call is smaller than this
parameter, the call needs to undergo Huawei power control generation III.

ID of the data link connection of the NSVC. It is an interworking parameter


which must be consistent on the BSC and the peer.
If the ratio of downlink flux to uplink flux is greater than or equal to the
threshold during the fast flux measurement, the downlink services takes
priority.
Whether the cell supports DLDC

Threshold for downlink edge handover. If the downlink receive level remains
less than this threshold for a period of time, the edge handover is triggered. If
the PBGT handover algorithm is enabled, this threshold can be decreased
accordingly. If the PBGT handover algorithm is disabled, over-coverage, cochannel interference, and adjacent channel interference may occur when this
threshold is set improperly. In addition, to ensure uplink-downlink balance, this
threshold needs to be adjusted according to the handover performance
statistics and actual network performance.
Filter adjustment factor for downlink power control. Setting this parameter high
helps to smooth the filtered values and to reduce the impact of poor
measurement reports on the filtered values. Setting this parameter low helps to
draw the filtered values close to the actual values and to heighten the power
control effect.

Upper quality threshold for Huawei power control generation III on a full rate
call. If the downlink receive quality level of a full rate call is greater than this
threshold, the call needs to undergo Huawei power control generation III.

Lower quality threshold for Huawei power control generation III on a full rate
call. If the downlink receive quality level of a full rate call is smaller than this
threshold, the call needs to undergo Huawei power control generation III.

Expanded size of the GPRS RLC window. This parameter is used to expand the
size of the GRPS RLC window. The expanded window size breaks the restrictions
of 64 defined in the protocol and reduces the probability of GRPS RLC window
stopping.

Upper quality threshold for Huawei power control generation III on a half rate
call. If the downlink receive quality level of a half rate call is greater than this
threshold, the call needs to undergo Huawei power control generation III.

Lower quality threshold for Huawei power control generation III on a half rate
call. If the downlink receive quality level of a half rate call is smallter than this
threshold, the call needs to undergo Huawei power control generation III.

Adjustment hysteresis 1 of AMR downlink coding rate (full rate). According to a


certain algorithm and the radio quality indication (RQI) in the call measurement
report, the MS and the BTS automatically adjust the current speech coding and
decoding rate. The adjustment threshold of coding rate is the threshold of the
RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means
0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy.
There may be multiple coding rates in the active coding set (ACS). Therefore,
there is an adjustment threshold and an adjustment hysteresis between every
two adjacent coding rates.

Adjustment hysteresis 2 of AMR downlink coding rate (full rate). According to a


certain algorithm and the radio quality indication (RQI) in the call measurement
report, the MS and the BTS automatically adjust the current speech coding and
decoding rate. The adjustment threshold of coding rate is the threshold of the
RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means
0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy.
There may be multiple coding rates in the active coding set (ACS). Therefore,
there is an adjustment threshold and an adjustment hysteresis between every
two adjacent coding rates.

Adjustment hysteresis 3 of AMR downlink coding rate (full rate). According to a


certain algorithm and the radio quality indication (RQI) in the call measurement
report, the MS and the BTS automatically adjust the current speech coding and
decoding rate. The adjustment threshold of coding rate is the threshold of the
RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means
0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy.
There may be multiple coding rates in the active coding set (ACS). Therefore,
there is an adjustment threshold and an adjustment hysteresis between every
two adjacent coding rates.

Adjustment hysteresis 1 of AMR downlink coding rate (half rate). According to a


certain algorithm and the radio quality indication (RQI) in the call measurement
report, the MS and the BTS automatically adjust the current speech coding and
decoding rate. The adjustment threshold of coding rate is the threshold of the
RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means
0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy.
There may be multiple coding rates in the active coding set (ACS). Therefore,
there is an adjustment threshold and an adjustment hysteresis between every
two adjacent coding rates.

Adjustment hysteresis 2 of AMR downlink coding rate (half rate). According to a


certain algorithm and the radio quality indication (RQI) in the call measurement
report, the MS and the BTS automatically adjust the current speech coding and
decoding rate. The adjustment threshold of coding rate is the threshold of the
RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means
0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy.
There may be multiple coding rates in the active coding set (ACS). Therefore,
there is an adjustment threshold and an adjustment hysteresis between every
two adjacent coding rates.

Adjustment hysteresis 3 of AMR downlink coding rate (half rate). According to a


certain algorithm and the radio quality indication (RQI) in the call measurement
report, the MS and the BTS automatically adjust the current speech coding and
decoding rate. The adjustment threshold of coding rate is the threshold of the
RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means
0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy.
There may be multiple coding rates in the active coding set (ACS). Therefore,
there is an adjustment threshold and an adjustment hysteresis between every
two adjacent coding rates.

Adjustment hysteresis 1 of AMR downlink coding rate (wide band). According to


a certain algorithm and the radio quality indication (RQI) in the call
measurement report, the MS and the BTS automatically adjust the current
speech coding and decoding rate. The adjustment threshold of coding rate is
the threshold of the RQI, which is the carrier-to-interference ratio of a call. The
RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be
deducted by analogy. There may be multiple coding rates in the active coding
set (ACS). Therefore, there is an adjustment threshold and an adjustment
hysteresis between every two adjacent coding rates.

Adjustment hysteresis 2 of AMR downlink coding rate (wide band). According to


a certain algorithm and the radio quality indication (RQI) in the call
measurement report, the MS and the BTS automatically adjust the current
speech coding and decoding rate. The adjustment threshold of coding rate is
the threshold of the RQI, which is the carrier-to-interference ratio of a call. The
RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be
deducted by analogy. There may be multiple coding rates in the active coding
set (ACS). Therefore, there is an adjustment threshold and an adjustment
hysteresis between every two adjacent coding rates.
Threshold for determining whether downlink interference exists. If the downlink
level is equal to or greater than "Interf.of DL Level Threshold" and the downlink
quality level is equal to or greater than "Interf.of DL Qual.Threshold", downlink
interference exists. The value range 0 to 63 is mapped to the range -110 dBm
to -47 dBm.

Threshold for determining whether downlink interference exists. If the downlink


level is equal to or greater than "Interf.of DL Level Threshold" and the downlink
quality level is equal to or greater than "Interf.of DL Qual.Threshold", downlink
interference exists.
When the downlink load of a cell is larger than the value of this parameter and
is smaller than "2G Cell DL Overload Congest Thred", the downlink of the cell is
in the basic congestion status.
Number of measurement reports sampled for averaging downlink signal
strength. A single measurement report may not reflect the actual network
situations accurately. Therefore, the BSC needs to average the measured values
in several successive measurement reports to reflect the radio environment.

Lower voice quality threshold associated with the automatic adjustment of the
AMR downlink handover threshold. The value of this parameter must be smaller
than or equal to the value of Downlink Long-term FER Target.

Target value of the voice quality automatically adjusted through the downlink
threshold of AMR handover

Upper voice quality threshold associated with the automatic adjustment of the
AMR handover downlink threshold.

Factor of downlink threshold adjustment. It indicates the linear relation between


the threshold adjustment value and the logarithmic FER.

Maximum step by which to decrease downlink power according to signal


strength

Maximum step by which to increase downlink power according to signal


strength

When the downlink load of a cell is greater than the value, the downlink of the
cell is in the overload congestion status.

Number of downlink measurement reports that the BSC predicts. The BSC takes
a while to confirm the power control effect of a power control command. Thus,
the BSC makes a power control decision based on a measurement report that
lags behind the changes in the receive level and quality instead of reflecting
the real-time radio environment. As a result, the power control is late.
To prevent late power control to a certain degree, the power control algorithm
involves a measurement report prediction filter. The BSC can sample several
downlink measurement reports in a short time and then weigh them to predict
future N measurement reports.
This parameter specifies the number N.

Quality level threshold for decreasing downlink signal power. If the BTS
transmits signals at a quality level less than this threshold, the BSC decreases
the power of the BTS. If (downlink receive level - "MAX Down Adj. PC Value by
Qual.") < "DL RX_LEV Lower Threshold", the BSC does not adjust the transmit
power.

Quality level threshold for increasing downlink signal power. If the BTS
transmits signals at a quality level greater than this threshold, the BSC
increases the power of the BTS. If (downlink receive level + "MAX Up Adj. PC
Value by Qual.") > "DL RX_LEV Upper Threshold", the BSC does not adjust the
transmit power.

Number of measurement reports sampled for averaging downlink signal quality.


A single measurement report may not reflect the actual network situations
accurately. Therefore, the BSC needs to average the measured values in
several successive measurement reports to reflect the radio environment.
During downlink power control, if the downlink receive quality level is equal to
or greater than "DL Qual, bad Trig Threshold", "DL RX_LEV Upper Threshold" is
increased by "DL Qual. Bad UpLEVDiff" to further increase the expected
downlink power level.
During downlink power control, if the downlink receive quality level is equal to
or greater than "DL Qual, bad Trig Threshold", "DL RX_LEV Upper Threshold" is
increased by "DL Qual. Bad UpLEVDiff" to further increase the expected
downlink power level.

Downlink quality threshold for emergency handover. This parameter is


represented as the product of 10 and a quality level that ranges from 0 to 7.
The emergency handover can be triggered only when the downlink receive
quality of an MS is greater(indicate bad quality) than this threshold.

Downlink quality limit for emergency handover in an AMR full rate call. The
value of this parameter corresponds to the quality levels (0 to 7) multiplied by
10. An emergency handover can be triggered only when the downlink reception
quality of an MS is higher than the value of this parameter, which indicates a
poor quality.

Downlink quality limit for emergency handover in an AMR half rate call. The
value of this parameter corresponds to the quality levels (0 to 7) multiplied by
10. An emergency handover can be triggered only when the downlink reception
quality of an MS is higher than the value of this parameter, which indicates a
poor quality.

This parameter specifies the downlink signal strength factor multiplied by 10


during the calculation of the downlink power control step. The downlink signal
strength factor is a coefficient indicating how much the signal strength is
considered during the calculation of the downlink power control step.
Length of the exponential filter for downlink signal strength. A single
measurement report may not reflect the actual network situations accurately.
Therefore, the BSC needs to filter the measured values in several successive
measurement reports to reflect the radio environment.

Upper receive level threshold for downlink power control. If the downlink
receive level is greater than this threshold, the power of the downlink signal
needs to be decreased.

Lower receive level threshold for downlink power control. If the downlink
receive level is smaller than this threshold, the power of the uplink signal needs
to be increased.

Length of the slide window filter for downlink signal strength. A single
measurement report may not reflect the actual network situations accurately.
Therefore, the BSC needs to filter the measured values in several successive
measurement reports to reflect the radio environment.
This parameter specifies the downlink quality level factor multiplied by 10
during the calculation of the downlink power control step. The downlink quality
level factor is a coefficient indicating how much the quality level is considered
during the calculation of the downlink power control step.
Length of the exponential filter for downlink signal quality. A single
measurement report may not reflect the actual network situations accurately.
Therefore, the BSC needs to filter the measured values in several successive
measurement reports to reflect the radio environment.
Length of the slide window filter for downlink signal quality. A single
measurement report may not reflect the actual network situations accurately.
Therefore, the BSC needs to filter the measured values in several successive
measurement reports to reflect the radio environment.
A power control step cannot exceed the step computed according to "III DL
RexLev Protect Factor" and "III DL RexQual Protect Factor".
A power control step cannot exceed the step computed according to "III DL
RexLev Protect Factor" and "III DL RexQual Protect Factor".

Upper threshold for downlink signal strength


If the downlink received signal level is greater than this threshold, a power
decrease is computed. Then, the power is decreased by the least of the power
decrease, maximum power adjustment step allowed by the quality zone to
which the received signal quality belongs, and "MAX Down Adj. PC Value by
Qual.".
Power decrease = downlink received signal level - ("DL RX_LEV Upper
Threshold" + "AMR DL RX_LEV Lower Threshold")/2
The maximum power adjustment step allowed by the quality zone is chosen
from "MAX Down Adj.Value Qual.Zone 0", "MAX Down Adj.Value Qual.Zone 1",
and "MAX Down Adj.Value Qual.Zone 2" according to the quality zone.

Lower threshold for downlink signal strength


If the downlink received signal level is less than this threshold, a power
increase is computed. Then, the power is increased by the least of the power
increase, "MAX Up Adj. PC Value by RX_LEV", and "MAX Up Adj. PC Value by
Qual.".
Power increase = ("DL RX_LEV Upper Threshold" + "AMR DL RX_LEV Lower
Threshold")/2 - downlink received signal level

Time interval between sending of the Packet Uplink Ack/Nack message and
setup of the DL TBF. After receiving the Packet Uplink Ack/Nack message (FAI =
1), the MS releases the UL TBF and starts to monitor CCCH. In this case, if the
MS receives the downlink assignment message before being handed over to
the CCCH, the MS fails to respond to the downlink assignment message.
Therefore, a delay is required for establishing DL TBF, to avoid such a situation.
That is, the DL TBF will not be set up immediately after the Packet Uplink
Ack/Nack message (FAI = 1) is sent. In this way, the MS can respond to the
downlink assignment message properly.

Interval for resending downlink test messages

Number of times of the BSC6900 resending downlink test messages after the
downlink test function is enabled. If the BSC6900 does not receive any
response message from the MS at the preset interval, the BSC6900 releases the
relevant voice group call service (VGCS) channel.

Adjustment threshold 1 of AMR downlink coding rate (full rate). According to a


certain algorithm and the RQI in the call measurement report, the MS and the
BTS automatically adjust the current speech coding and decoding rate. The
adjustment threshold of coding rate is the threshold of the RQI, which is the
carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI
value 2 means 1 dB, and others can be deducted by analogy. There may be
multiple coding rates in the ACS. Therefore, there is an adjustment threshold
and an adjustment hysteresis between every two adjacent coding rates.

Adjustment threshold 2 of AMR downlink coding rate (full rate). According to a


certain algorithm and the RQI in the call measurement report, the MS and the
BTS automatically adjust the current speech coding and decoding rate. The
adjustment threshold of coding rate is the threshold of the RQI, which is the
carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI
value 2 means 1 dB, and others can be deducted by analogy. There may be
multiple coding rates in the ACS. Therefore, there is an adjustment threshold
and an adjustment hysteresis between every two adjacent coding rates.

Adjustment threshold 3 of AMR downlink coding rate (full rate). The adjustment
thresholds and the hysteresis of coding rate must meet the following
conditions: AMR Coding Rate adj.th (n) < AMR Coding Rate adj.th (n + 1), n = 1
or 2; [AMR Coding Rate adj.th (n) + AMR Coding Rate adj.hyst (n)] < [AMR
Coding Rate adj.th (n + 1) + AMR Coding Rate adj.hyst (n + 1)], n = 1 or 2.

Adjustment threshold 1 of AMR downlink coding rate (half rate). According to a


certain algorithm and the RQI in the call measurement report, the MS and the
BTS automatically adjust the current speech coding and decoding rate. The
adjustment threshold of coding rate is the threshold of the RQI, which is the
carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI
value 2 means 1 dB, and others can be deducted by analogy. There may be
multiple coding rates in the ACS. Therefore, there is an adjustment threshold
and an adjustment hysteresis between every two adjacent coding rates.

Adjustment threshold 2 of AMR downlink coding rate (half rate). According to a


certain algorithm and the RQI in the call measurement report, the MS and the
BTS automatically adjust the current speech coding and decoding rate. The
adjustment threshold of coding rate is the threshold of the RQI, which is the
carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI
value 2 means 1 dB, and others can be deducted by analogy. There may be
multiple coding rates in the ACS. Therefore, there is an adjustment threshold
and an adjustment hysteresis between every two adjacent coding rates.

Adjustment threshold 3 of AMR downlink coding rate (half rate). According to a


certain algorithm and the RQI in the call measurement report, the MS and the
BTS automatically adjust the current speech coding and decoding rate. The
adjustment threshold of coding rate is the threshold of the RQI, which is the
carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI
value 2 means 1 dB, and others can be deducted by analogy. There may be
multiple coding rates in the ACS. Therefore, there is an adjustment threshold
and an adjustment hysteresis between every two adjacent coding rates.

Adjustment threshold 1 of AMR downlink coding rate (wide band). According to


a certain algorithm and the RQI in the call measurement report, the MS and the
BTS automatically adjust the current speech coding and decoding rate. The
adjustment threshold of coding rate is the threshold of the RQI, which is the
carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI
value 2 means 1 dB, and others can be deducted by analogy. There may be
multiple coding rates in the ACS. Therefore, there is an adjustment threshold
and an adjustment hysteresis between every two adjacent coding rates.

Adjustment threshold 2 of AMR downlink coding rate (wide band). According to


a certain algorithm and the RQI in the call measurement report, the MS and the
BTS automatically adjust the current speech coding and decoding rate. The
adjustment threshold of coding rate is the threshold of the RQI, which is the
carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI
value 2 means 1 dB, and others can be deducted by analogy. There may be
multiple coding rates in the ACS. Therefore, there is an adjustment threshold
and an adjustment hysteresis between every two adjacent coding rates.

MDU board number when the antenna pass of downlink tributary A is selected

MDU board number when the antenna pass of downlink tributary B is selected

Clock domain required by the slave side in the 1588V2 protocol. This parameter
is valid when the 1588CLK type is configured.

Coding scheme of the default GPRS downlink. Dynamic adjustment coding: the
coding scheme used during initial access transmission. If the downlink uses the
fixed coding scheme, the TBF uses the fixed coding scheme.
Default coding scheme of the downlink EDGE link. If the downlink adopts the
dynamic adjustment coding scheme, this parameter can be used to set the
coding scheme for transmission during initial access. If the downlink uses the
fixed coding scheme, the TBF uses the fixed coding scheme.
Default coding scheme used on the downlink EGPRS2-A link. If the downlink
uses the dynamic coding scheme, this parameter specifies the coding scheme
that is used for the transmission in initial access. If the downlink uses the fixed
coding scheme, the TBF uses the fixed coding scheme.
Fixed coding scheme that is used on the downlink EGPRS2-A link. If the
downlink uses the fixed coding scheme, this parameter can be set MSC1-4,
MSC7-8 or DAS5-12.. If the downlink uses the dynamic coding scheme, this
parameter is set to UNFIXED.
Adjustment mode of the downlink GPRS link coding scheme. If the fixed coding
scheme is used, this parameter is set to a value ranging from CS1 to CS4. If the
dynamic coding scheme is used, this parameter is set to UNFIXED.
Coding scheme of the downlink EDGE link. If the downlink uses the fixed coding
scheme, this parameter is set to a value ranging from MCS1 to MCS9. If the
downlink uses the dynamic adjustment coding scheme, this parameter is set to
UNFIXED.

Whether to allow BTS power control

Whether to prohibit sending point-to-point short messages. If necessary, this


parameter is used for controlling whether to send downlink short messages
from a specific cell so as to ensure sufficient radio channel resources for normal
calls.

Delay of releasing the downlink TBF. After the last downlink RLC data block is
transmitted on the network side and all the transmitted downlink data blocks
are received, the MS is not informed to stop this downlink TBF. Instead, the
state of the last data block is forcibly set to "not received" and the RRBP flag of
the last data block is retransmitted continuously so that the downlink TBF is not
released. During the downlink delay release, if the upper layer of the network
side needs to transmit downlink data, the downlink RLC block for unpacking can
be transmitted in the downlink TBF for delay release. The state of the downlink
TBF is changed from delay releasing to downlink transmitting. In addition, the
MS must respond to the Packet Downlink Ack/Nack message through the uplink
data block of the RRBP to exchange messages with the network side. When the
MS needs to send data, the MS can send the uplink request to the network
sides through the Packet Downlink Ack/Nack with the channel request
description. If this parameter is set to 0, the release delay of downlink TBF is
disabled.

Retransmission threshold when the coding mode of the downlink TBF is


changed from CS2 to CS1. When the downlink TBF retransmission rate is
greater than or equals to this value, the coding mode of the TBF is changed
from CS2 to CS1.
Retransmission threshold when the coding mode of the TBF is changed from
CS3 to CS2. When the TBF retransmission rate is greater than or equals to this
value, the coding mode of the TBF is changed from CS3 to CS2.
Retransmission threshold when the coding mode of the downlink TBF is
changed from CS4 to CS3. When the downlink TBF Retransmission rate is
greater than or equals to this value, the coding mode of the TBF is changed
from CS4 to CS3.
Retransmission threshold when the coding mode of the downlink TBF is
changed from CS1 to CS2. When the TBF retransmission rate is less than or
equals to this value, the coding mode of the TBF is changed from CS1 to CS2.
Retransmission threshold when the coding mode of the TBF is changed from
CS2 to CS3. When the downlink TBF retransmission rate is less than or equals
to CS2 to CS1, the coding mode of the TBF is changed from CS2 to CS3.
Retransmission threshold when the coding mode of the downlink TBF is
changed from CS3 to CS4. When the downlink TBF retransmission rate is less
than or equals to this value, the coding mode of the downlink TBF is changed
from CS3 to CS4.
Door status alarm switch

Dual-antenna gain used to estimate the downlink power during assignment


As an integer, the DSP code can be expressed by a decimal digit or a
hexadecimal digit. If the DSP code is expressed by a hexadecimal digit, H' is
added before the number.
DSP code expressed in the format of segments 8-8-8
As a key field for identifying the block of A interface CIC status, it indicates the
DPC group index of the circuit ID of the A interface to be blocked.
Index of the DPC group. see "ADD GCNNODE" command.
Index of a DPC group.
When multiple DPCs or one DPC serves as a logical entity, this logical entity is
called a DPC group.
When the MSC pool function is activated, the user plane resources on the A
interface are shared among the MSCs in the pool, and thus load balancing is
achieved.
DSP type.
STP: indicates the signaling transfer point.
A: indicates the signaling point of the A interface control signaling plane.
IUR_G: indicates the signaling point of the base station controller that is
connected to the BSC.
LB: indicates the signaling point of the LB interface.

The DSP index uniquely identifies a DSP.

Iur-g DPC index of a neighboring RNC


Maximum signal level difference between the neighbor cell and the serving cell
for triggering directed retry

Whether to optimize the call drops resulting from Abis territorial link fault. The
value 0 means "optimize" and 1 means "not optimize". If the value of this
parameter is 0, the call drops resulting from this cause are not brought into the
statistics of call drops.
Whether to optimize the call drops resulting from connection failure (handover
access failure). The value 0 means "optimize" and 1 means "not optimize". If
the value of this parameter is 0, the call drops resulting from this cause are not
brought into the statistics of call drops.
Whether to optimize the call drops resulting from connection failure, operation
and maintenance (OM) intervention. The value 0 means "optimize" and 1
means "not optimize". If the value of this parameter is 0, the call drops
resulting from this cause are not brought into the statistics of call drops.
Whether to optimize the call drops resulting from a connection failure except
for handover access failure, OM intervention, radio link failure, and
unavailability of radio resources. The value 0 means "optimize" and 1 means
"not optimize". If the value of this parameter is 0, the call drops resulting from
this cause are not brought into the statistics of call drops.
Whether to optimize the call drops resulting from connection failure (radio link
failure). The value 0 means "optimize" and 1 means "not optimize". If the value
of this parameter is 0, the call drops resulting from this cause are not brought
into the statistics of call drops.
Whether to optimize the call drops resulting from connection failure
(unavailability of radio resources). The value 0 means "optimize" and 1 means
"not optimize". If the value of this parameter is 0, the call drops resulting from
this cause are not brought into the statistics of call drops.
Whether to optimize the call drops resulting from equipment fault. The value 0
means "optimize" and 1 means "not optimize". If the value of this parameter is
0, the call drops resulting from this cause are not brought into the statistics of
call drops.
Whether to optimize the call drops resulting from error indication (unsolicited
DM response). The value 0 means "optimize" and 1 means "not optimize". If the
value of this parameter is 0, the call drops resulting from this cause are not
brought into the statistics of call drops.
Whether to optimize the call drops resulting from error indication (sequence
error). The value 0 means "optimize" and 1 means "not optimize". If the value
of this parameter is 0, the call drops resulting from this cause are not brought
into the statistics of call drops.

Whether to optimize the call drops resulting from error indication (T200
timeout). The value 0 means "optimize" and 1 means "not optimize". If the
value of this parameter is 0, the call drops resulting from this cause are not
brought into the statistics of call drops.
Whether to optimize the call drops resulting from forced handover failure. The
value 0 means "optimize" and 1 means "not optimize". If the value of this
parameter is 0, the call drops resulting from this cause are not brought into the
statistics of call drops.
Whether to optimize the call drops resulting from incoming-BSC handover
timeout. The value 0 means "optimize" and 1 means "not optimize". If the
value of this parameter is 0, the call drops resulting from this cause are not
brought into the statistics of call drops.
Whether to optimize the call drops resulting from outgoing internal inter-cell
handover timeout. The value 0 means "optimize" and 1 means "not optimize".
If the value of this parameter is 0, the call drops resulting from this cause are
not brought into the statistics of call drops.
Whether to optimize the call drops resulting from intra-cell handover timeout.
The value 0 means "optimize" and 1 means "not optimize". If the value of this
parameter is 0, the call drops resulting from this cause are not brought into the
statistics of call drops.
Whether to optimize the call drops resulting from no MS measurement reports
for a long time. The value 0 means "optimize" and 1 means "not optimize". If
the value of this parameter is 0, the call drops resulting from this cause are not
brought into the statistics of call drops.
Whether to optimize the call drops resulting from outgoing-BSC handover
timeout. The value 0 means "optimize" and 1 means "not optimize". If the
value of this parameter is 0, the call drops resulting from this cause are not
brought into the statistics of call drops.
Whether to optimize the call drops resulting from release indications. The value
0 means "optimize" and 1 means "not optimize". If the value of this parameter
is 0, the call drops resulting from this cause are not brought into the statistics
of call drops.
Whether to optimize the call drops resulting from resource check. The value 0
means "optimize" and 1 means "not optimize". If the value of this parameter is
0, the call drops resulting from this cause are not brought into the statistics of
call drops.
If the duration for buffering the data in queue 0 is more than or equals to the
value of this parameter, the subsequent packets added to queue 0 are
discarded.
If the duration for buffering the data in queue 1 is more than or equals to the
value of this parameter, the subsequent packets added to queue 1 are
discarded.

If the duration for buffering the data in queue 2 is more than or equals to the
value of this parameter, the subsequent packets added to queue 2 are
discarded.
If the duration for buffering the data in queue 3 is more than or equals to the
value of this parameter, the subsequent packets added to queue 3 are
discarded.
If the duration for buffering the data in queue 4 is more than or equals to the
value of this parameter, the subsequent packets added to queue 4 are
discarded.
If the duration for buffering the data in queue 5 is more than or equals to the
value of this parameter, the subsequent packets added to queue 5 are
discarded.
This parameter specifies the interval at which the power of a TRX is continually
decreased.
This parameter specifies the delay time before decreasing the power of the
TRXs.
This parameter specifies the step by which the power of a TRX is decreased at
a time.

Whether to support the discontinuous reception mechanism (DRX). To reduce


the power consumption, the DRX is introduced into the GSM Specification. MSs
supporting the DRX can consume less power to receive interested broadcast
messages. This prolongs the service time of MS batteries.
BSCs supporting the DRX must send scheduling messages to MSs so that the
MSs can use the DRX function. The period occupied by broadcast messages
that are contained in a scheduling message is called a scheduling period. In the
sending sequence, a scheduling message contain the description of each short
message to be broadcasted and the position of each broadcast message in the
scheduling period.

Duration of the timer for entering the DRX mode. DRX is the parameter in the
cell broadcast message. It indicates non-continuous receiving mode. When the
MS is switched from the packet transmission mode to the idle mode, the MS
needs to maintain the none DRX mode for a moment. After the TBF is released,
in the period when the MS is in non-DRX mode, the MS monitors all the CCCH
blocks and the BSC stores the context of the MS. The reservation duration is
determined by the minimum value of DRX_Timer_Max and NON_DRX_TIMER.
The parameter NON_DRX_TIMER is negotiated with the SGSN during GPRS
attaching of the MS. Normally, this value is greater than that of
DRX_TIMER_MAX. Therefore, the value of DRX_TIMER_MAX is used.
0: switch to the DRX mode immediately;
1: switch to the DRX mode in one second.
Value n indicates that the MS enters the DRX mode n seconds later.

Whether to start the dehumidification equipment of the BTS.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Number of the E1T1 port for bearing the PPP link
Number of the E1T1 port for bearing the PPP link
The DSCP is a field of the IP data packet. It is used to assign the differentiated
service to the communication networks. The DSCP code is used to label each
data packet on the network and allocate the corresponding service levels. In
the same network environment, the larger the DSCP is, the higher the priority
is.
Service code of the PING command, used to identify the PING command
Differentiated service code is used to identify the service priority of the user.
DSCP to be contained in the header of an IP packet. According to this
parameter, the router provides differentiated services for packet streams. If this
parameter is greater, the service level is higher. This parameter is valid only
when the transport type is set to IP.
Duration for recovering all the DSPs. This timer is started when the first DSP is
recovered. When all the DSPs of the local subrack are recovered or the timer
expires, the timer is stopped. The cells are distributed on the recovered DSPs.
Number of the DSP. If you do not specify this parameter, all DSPs are specified.

Meanings:DSP No.
Value range:0~21
Content:none
Recommended value(default value):none
Number of the DSP in the DPU board

Number of the DSP where the alarm is generated

Target DSP number


This parameter specifies the value of the timer set to wait the fault recovery
before the cell redistribution on the DSP. When a fault is detected on a DSP, this
timer starts. If the fault is recovered before the timer expires, the cells on the
DSP are not be redistributed. Otherwise, the cell redistribution is triggered after
the timer expires.
Whether daylight saving time has to be used

Name of the destination file

Destination IP address

Destination IP address of BFD Session.


Destination IP address

Subnet mask of BTS Route.

Subnet mask
Destination of timeslot cross

Target timeslot mask

Threshold of the load in the target cell for the directed retry. Only a cell whose
load is lower than or equal to this threshold can be selected as a candicate
target cell.
Type of the DRX supporting the VGCS service. An MS reads the NCH only when
a new notification message of group call arrives. This helps save power of the
MS. This parameter is mandatory for a SAGEM MS.
Downlink TRX index number of the newly added board

Index number of the downlink tributary

TRX board pass number connected with the downlink tributary

TRX board pass number connected with the downlink tributary


Number of the slot where the TRX board that connects to downlink tributary is
located
Number of the slot where the TRX board that connects to downlink tributary is
located
Number of the subrack where the TRX board that connects to downlink
tributary is located
Number of the subrack where the TRX board that connects to downlink
tributary is located
Whether a BTS randomizes the dummy bits in all the signaling messages that
the BTS sends to an MS. That is, dummy bits are randomized rather than filled
on the basis of 0x2B.
The duplex mode of FE port is duplex or half-duplex.

Duration for starting the BTS test

Duration for starting the TRX idle timeslot test

Duration for starting the BTS test

Duration for starting the TRX idle timeslot test

Downlink multiplex threshold of dynamic channel conversion. When the


subscriber number on the channel reaches the value (threshold/10), the
dynamic channel conversion is triggered. We recommand that the value of
"Downlink Multiplex Threshold of Dynamic Channel Conversion" should be less
than "PDCH Downlink Multiplex Threshold" for triggering converting dynamic
channel in time and reducing PDCH multiplex.

An MS can be used to test the Um interface software synchronization only when


the DL signal strength after the power control compensation in the test cell and
the observed cell is higher than this limit.

Number of a DXX. It is unique in one BSC6900 and uniquely identifies a DXX.

Number of a DXX. It is unique in one BSC6900 and uniquely identifies a DXX.

Number of the upper DXX port

Time to wait for releasing the dynamic channel after the TBF on the dynamic
channel is released. When all the TBFs on the channel are released, the
dynamic channel is not released at once. Instead, the timer is started when the
channels are idle. Before the timer expires, if new service request is received,
the dynamic channel is still occupied and timer is stopped; otherwise, the
dynamic channel is released after the timer expired.

Mode of preempting the dynamic channel for the CS domain and PS domain.
Only the channel configured in the TCH/F mode can be preempted.
"Preempt all dynamic TCHFs" indicates the circuit domain can preempt all the
dynamic channels.
"No preempt of CCHs" indicates the circuit domain can preempt all the dynamic
channels except the CCHs.
"No preempt of service TCHF" indicates the circuit domain cannot preempt all
the dynamic channels of bearer services.

Number of full-rate TCHs reserved for the CS domain. This parameter is valid
only when "Level of Preempting Dynamic Channel" is set to LEVEL1 or LEVEL2.
This parameter specifies whether to allow the BSC6900 to enable the TRX
Intelligent Shutdown feature on a cell.
Whether to enable the cell to support dynamic transmit diversity or dynamic
PBT
Duration for the test in E1 mode
Number of the E1 port. For the BTS3012, BTS3012AE, BTS3012 II and the UTRP
board in SingleRAN BTSs, the number can be a value from 0 to 7. For other
BTSs, the number can be a value from 0 to 3.
Number of the E1 port on the BTS connected to the BSC.

Type of the transmission board

Number of the E1/T1 port from which the BTS extracts the transport clock. This
parameter is valid only when the clock type is set to IP_TRANSFER.
E1/T1 port number

Number of the port extended by the backboard TOP communication mechanism


of the BTS. The TOP relation can be configured between the port on the BTS
board panel and the port on the BTS backplane, thus extending the ports. This
function is used for the configuration of the multi-mode base station. The range
16-19 indicates the number of the E1/T1 port on the backplane of the primary
BBU and the range 24-27 indicates the number of the E1/T1 port on the
backplane of the secondary BBU. A BBU supports only the E1 port numbered
from 16 to 19 on the backplane.
Type of the E1/T1 from which the BTS extracts the transport clock. This
parameter is valid only when the clock type is set to IP_TRANSFER.
Peer IP address to be checked. The input address (CHKIPADDR) must be the
address (regardless of the network segment address or host address of the
peer address) in the network segment specified by the (PEERIPADDR,
PEERMASK).

As a performance counter for 3G cells, Ec/No indicates the ratio of the energy
per received chip to the spectral noise power density.
If the Ec/No of a 3G neighbor cell is greater than "HOECNOTH3G" plus this
parameter, the neighbor cell is listed in the candidate cell queue.

Threshold for determining the layer of the 3G neighbor cell. If the Ec/No of the
3G neighbor cell is less than this threshold, the neighbor cell is set to the
lowest layer (layer 5).

The early classmark sending control (ECSC) parameter specifies whether the
MSs in a cell use early classmark sending. After a successful immediate
assignment, the MS sends additional classmark information to the network as
early as possible. The additional classmark information mainly contains the
CM3 (classmark 3) information. The CM3 (classmark 3) information contains
the frequency band support capability of the MS (used for the future channel
assignment), power information about each frequency band supported by the
MS (used for the handover between different frequency bands), and encryption
capability of the MS.

End serial number of the alarm record

End date of the alarm record. By default, the end date is 2037-12-31.

End date of the alarm record. By default, the end date is 2037-12-31.

Date when the scheduled task is stopped

End date

End date of the daylight saving time

According to the P/N rule, if the conditions for the handover between the
subcells of an enhanced dual-frequency network are met during P of N
measurements, the handover is triggered.
This parameter specifies the number P.

According to the P/N rule, if the conditions for the handover between the
subcells of an enhanced dual-frequency network are met during P of N
measurements, the handover is triggered.
This parameter specifies the number N.

If the current system flow control level is greater than this parameter, the
handover between the underlaid and overlaid subcells due to low or high load
in the underlaid subcell is not allowed. System flux thresholds correspond to
the system flux obtained based on message packets, CPU load, and FID
queuing load. The system flux level is the current flux control level of the
system.
0-11: There are 12 flow control levels. Where, 0 indicates the lowest level and
11 indicates the highest level.
The handover performed over the maximum threshold may have tremendous
impacts on the system. Thus, this parameter should not be set to a higher
value. 1) The flow control level algorithm for the assigned system messages:
[(Average Message Usage - Inner Flow Control Discard Begin Threshold)/(Inner
Flow Control Discard All Threshold - Inner Flow Control Discard Begin Threshold)
x 100]/10+1 (round-down for division operation). If the value is smaller than
Inner Flow Control Discard Begin Threshold, Level 0 is used. If the value is equal
to or greater than Inner Flow Control Discard Begin Threshold, the level is
calculated. The value range is from 0 to 11.
2) Flow control threshold for the CPU to start to discard the channel access
messages and paging messages: 80%
. Flow control threshold for the CPU to discard all channel access messages and
paging messages: 100%
. CPU usage smaller than 80% corresponds to level 0. CPU usage equal to or
greater than CPU flow control threshold 80% corresponds to level 2. An increase
of 5% means an increase of 2 levels. Level 10 is the highest. The level value
can be 0, 2, 4, 6, 8, and 10.

Whether the current cell supports EDGE

According to the P/N rule, if a neighbor cell meets the conditions for selecting
the neighbor cell for edge handover in P of N measurement reports, the edge
handover to the neighbor cell is triggered.
This parameter specifies the number P.

According to the P/N rule, if a neighbor cell meets the conditions for selecting
the neighbor cell for edge handover in P of N measurement reports, the edge
handover to the neighbor cell is triggered.
This parameter specifies the number N.

According to the P/N rule, if the conditions for edge handover are met in P of N
measurement reports, the handover is triggered.
This parameter specifies the number P.

According to the P/N rule, if the conditions for edge handover are met for P
seconds within N seconds, the handover is triggered.
This parameter specifies the number P.

According to the P/N rule, if the conditions for edge handover are met in P of N
measurement reports, the handover is triggered.
This parameter specifies the number N.

According to the P/N rule, if the conditions for edge handover are met for P
seconds within N seconds, the handover is triggered.
This parameter specifies the number N.

Effect Immediately Flag(reserve)

Whether to support the 11-bit EGPRS access request

Whether the current cell supports EGPRS2-A


Used for EDGE 8PSK transmission quality statistics. If MEAN_BEP is less than or
equals to this threshold, the transmission quality is regarded to be deteriorated.
MEAN_BEP indicates the average error code rate in one measurement report
period.
Used for EDGE GMSK transmission quality statistics. If MEAN_BEP is less than or
equals to this threshold, the transmission quality is regarded deteriorated.
MEAN_BEP indicates the average error code rate in one measurement report
period.

Type of the end date. "WEEK" indicates that the end date is a weekday. "DATE"
indicates that the end date is a month day. "DATEWEEK" indicates the end date
is expressed by a combination of weekday and month day.
Priority level of an emergency call. If this parameter is set to 15, the functions
of reserving TCHs for emergency calls and preempting TCHs are not enabled. If
the two functions need to be enabled, set this parameter to a value from 1 to
14. If the value of "Emergency Call Preemption Permitted" is ON, this parameter
can also be used for TCH preemption. The value 1 means the highest priority
and 14 means the lowest.
Whether to verify the centralized signaling link in the case of the link
establishment. ON: emergency verification, that is, the verification is not
required. OFF: non emergency verification, that is, the verification is required
during the establishment of a signaling link in a link set. Through verification,
the stable operation state of a signaling link can be ensured. You are advised to
use the normal verification. That is, the emergency verification switch is set to
OFF.

Error emit threshold.

Differentiated service code of the specified EML

Whether to allow the function of enhanced multi-level precedence and


preemption (eMLPP). With the eMLPP function enabled, the network can use
different policies such as queuing, preemption, or directed retry based on the
priorities of different calls when network resources are occupied. If this
parameter is set to YES, when preemption occurs, the MS with the lowest
priority initiates a handover, and the MS with a higher priority seizes the idle
channel after a handover. If this parameter is set to NO, an MS with a lower
priority releases the channel, the MS with a higher priority seizes the idle
channel after the release.
The eMLPP has up to seven priorities: A, B, 0, 1, 2, 3, and 4. The two highest
priorities A and B are internally reserved for local use only. Priorities 0 to 4 can
be subscribed by MSs for global use.
With the support of the MSC, HLR, and mobile terminal (containing a SIM card),
the eMLPP function can be perfectly implemented.
Whether to include the eMLPP Priority information element in the Paging
Command message over the Abis interface when "Allow eMLPP" is set to YES
and the eMLPP flag in the Bitmap information element of the Paging message
received from the MSC is 1

Indicating whether the eMLPP function is enabled in a cell and indicating the
eMLPP priority of the cell. From high to low, the priorities are A, B, 0, 1, 2, 3, 4
and No Priority. No Priority is the lowest.
Service priority of the specified EML
Service priority of the extension maintenance link (EML).0 is the highest
priority.
Specified EML Vlan Id

Month on which DST ends

IP address of the NE management system

Whether to enable the fallback function for the BTS

Whether to enable the power supply of the TMA

Encryption algorithm supported by the BSS side

Encryption mode used when the NE serves as the FTP client


AUTO: indicating that the FTP client automatically selects the encryption mode
PLAINTEXT: indicating that the plain text mode is used forcibly.
ENCRYPTED: indicating that the encrypted mode is used forcibly.
Encryption mode supported when the NE serves as the FTP server
AUTO: indicating that the FTP client automatically selects the encryption mode
PLAINTEXT: indicating that the plain text mode is used forcibly.
ENCRYPTED: indicating that the encrypted mode is used forcibly.

Whether to enable end-to-end user tracing for the BSC. If this parameter is set
to YES, the BSC starts end-to-end user tracing after the BSC receives the MSC
Invoke Trace or BSS Invoke Trace message from the MSC.
End number of the alarm record
It indicates the end CIC of the A interface CIC segment. When operation mode
is set to OPC index, DPC group index, BSC ID, or CIC, the parameter is
mandatory.
It indicates the end CIC of the Pb interface CIC segment. If the search object
mode is set to search by the specified range, the parameter is mandatory.

This parameter specifies the end date of a period during which the TRX
Intelligent Shutdown feature is disabled.

If the ambient temperature reaches the value of this parameter, the heater is
shut down.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

This parameter specifies the end month of a period during which the TRX
Intelligent Shutdown feature is disabled.

Number of the end sub-timeslot

This parameter specifies the time for dynamically disabling the TRX Intelligent
Shutdown feature each day.

It indicates the end CIC of the A interface CIC segment. When Operation mode
is set to subrack No., slot No., port No., or CIC, the parameter is mandatory.

It indicates the end CIC of the Ater interface CIC segment.

Number of the end timeslot


Status of the scheduled task. This parameter determines whether to start the
scheduled task.
Status of the scheduled subtask to be added

If the load of the underlaid subcell is greater than this threshold, certain calls in
the underlaid subcell are handed over to the overlaid subcell to balance the
traffic between the overlaid and underlaid subcells.

Whether to support PS downlink MAC back pressures in GSM. When the buffer is
overflowed, the L2 transmission rate is limited if "User Plane DL Flow Ctrl
Switch" is "ON". Thus, the data blocks are not lost. If "User Plane DL Flow Ctrl
Switch" is "OFF", the L2 transmission rate is not limited. In this case, the loss of
data blocks may occur. When "User Plane DL Flow Ctrl Switch" is set to "ON",
the LDR needs to be disabled through the "SET LDR" command.

Whether to enable the enhanced concentric cell algorithm in a concentric cell.


If a cell supports the enhanced concentric cell function, when an overlaid-tounderlaid handover or an underlaid-to-overlaid handover is decided, the MS
compares the receive level value respectively with the values of "OtoU HO
Received Level Threshold" and "UtoO HO Received Level Threshold" in "SET
GCELLHOIUO" to decide whether to trigger an enhanced concentric cell
handover.
If the cell does not support the enhanced concentric cell function, the MS
compares the actual receive level value with the threshold of receive level to
decide whether to trigger a concentric cell handover. In addition, when an
underlaid-to-overlaid handover is decided, the underlay cell load is considered.

If all the calls in the overlaid subcell are handed over to the underlaid subcell
when the channel seizure ratio of the underlaid subcell is less than "En Iuo Out
Cell Low Load Thred", the BSC load increases sharply. In this case, the target
subcell may be congested and drop calls. To avoid such a problem, the
hierarchical load-based handover algorithm is used to hand over the calls from
the overlaid subcell to the underlaid cell level by level.
This parameter specifies the period of the handover at each hierarchy level.

Signal level step for the hierarchical load-based handover from the overlaid
subcell to the underlaid subcell

If the load of the underlaid subcell is less than this threshold, certain calls in the
overlaid subcell are handed over to the underlaid subcell to balance the traffic
between the overlaid and underlaid subcells.

When this parameter is set to "ON", if there are no available Abis transmission
resources, a high-priority user can preempt the transmission resources of a lowpriority user. If the preemption succeeds, a call drop occurs at the low-priority
user.
When this parameter is set to "ON", if there are no available Abis transmission
resources, the BSC6900 starts the queuing procedure for the services to wait
for available transmission resources.

If the load of the underlaid subcell is greater than this threshold, the period of
the load-based handover from the underlaid subcell to the overlaid subcell, "UL
Subcell Load Hierarchical HO Periods", is decreased by "MOD Step LEN of UL
Load HO Period" every second to accelerate the handover.

Whether to enable the cell to centralize two busy half rate TCHs in different
timeslots into one timeslot through handover and then to combine the two idle
half rate TCHs in the other timeslot into one full rate TCH dynamically

Type of the destination entity. For details, see RFC4666.


M3UA_ASP: suggested to use when there is a signaling transfer point (STP)
between the local entity and the destination entity
M3UA_IPSP: suggested to use when there is no signaling transfer point (STP)
between the local entity and the destination entity
M3UA_SS7SP: suggested to use when the destination entity is a narrowband
signaling point
M3UA_SP: represents all types of the destination entity
Type of the M3UA local entity. For details about the ASP and IPSP, see RFC4666.
M3UA_ASP: suggested to use when there is a signaling transfer point (STP)
between the local entity and the destination entity
M3UA_IPSP: suggested to use when there is no signaling transfer point (STP)
between the local entity and the destination entity

Initial signal level used to compute the handover zone for an MS during the
hierarchical load-based handover from the underlaid subcell to the overlaid
subcell of the enhanced concentric cell

Whether to enable the enhanced packet loss concealment (EPLC) function


Return code of the command. If this parameter is specified, only the
corresponding record is displayed. If this parameter is not specified, the return
code is not considered.

Whether to disable emergency calls. For the MSs of access levels 0 to 9, if the
value of this parameter is NO, emergency calls are enabled. For the MSs of
access levels 11 to 15, emergency calls are disabled only when the relevant
access control bit is set to 0 and this parameter is set to YES.

Error-frame alarm threshold

Error-frame detect switch

Differentiated service code of the specified ESL

Service priority of the ESL


Priority of a service running over an extended signaling link (ESL). ESLs are
used for more reliably transmitting important signaling messages.0 is the
highest priority.
Specified ESL Vlan Id

End synchronization number of the alarm record

Timer for the BSC waiting for an Establish Indication message after sending an
Immediate Assignment message. If T3101 expires before the BSC receives an
Establish Indication message, the BSS releases the seized SDCCH.

Whether to add the TA value to a complete layer-3 message to provide the LCS
function on the A interface
When the OML is switched to a port where the connection is successfully
established, the switchover cannot be performed over a certain period of time,
which is specified as ring II rotating penalty time. In this manner, frequent
switchover between the ports due to intermittent blinking can be avoided.

End time of the alarm record. By default, the end time is 23:59:59.

End time of the alarm record. By default, the end time is 23:59:59.
The operation time of the log record is prior to this time. If this parameter is not
specified, the end time is not limited.
Time when the scheduled subtask is stopped. If the time mode is set to
"DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should set this parameter.
Execution mode of the commands
1. ONE_BY_ONE: indicating that the commands are executed one by one
according to the execution sequence. Only one command can be executed
once.
2. PARALLEL: indicating that multiple commands are executed in parallel.
Multiple commands can be executed once.
The operation time of the log record is prior to this time. If this parameter is not
specified, the end time is not limited.
End date and time of a broadcast message. This is a key parameter for
identifying a simple cell broadcast message. You can use "DSP GSMSCB" to
query and obtain the value of this parameter.
End time of DST

End date of the user operation. Input format: YYYY&MM&DD

End time

Type of the log to be queried. The result is displayed by the specified type.

End time of the user operation. The input format of this parameter is
HH&MM&SS.
Weekday on which DST ends

Sequence of the end week of DST

Upper limit of extended output analog signal 1. If "Sensor Type of External


Analog 1" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of
External Analog 1" is set to CURRENT, the unit of this parameter is A.

Lower limit of extended output analog signal 1. If "Sensor Type of External


Analog 1" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of
External Analog 1" is set to CURRENT, the unit of this parameter is A.

Sensor type of extended analog signal 1

Maximum measurement range of extended analog signal 1. If "Sensor Type of


External Analog 1" is set to VOLTAGE, the unit of this parameter is V; if "Sensor
Type of External Analog 1" is set to CURRENT, the unit of this parameter is A.

Minimum measurement range of extended analog signal 1. If "Sensor Type of


External Analog 1" is set to VOLTAGE, the unit of this parameter is V; if "Sensor
Type of External Analog 1" is set to CURRENT, the unit of this parameter is A.

Upper limit of extended output analog signal 2. If "Sensor Type of External


Analog 2" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of
External Analog 2" is set to CURRENT, the unit of this parameter is A.

Lower limit of extended output analog signal 2. If "Sensor Type of External


Analog 2" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of
External Analog 2" is set to CURRENT, the unit of this parameter is A.

Sensor type of extended analog signal 2

Maximum measurement range of extended analog signal 2. If "Sensor Type of


External Analog 2" is set to VOLTAGE, the unit of this parameter is V; if "Sensor
Type of External Analog 2" is set to CURRENT, the unit of this parameter is A.

Minimum measurement range of extended analog signal 2. If "Sensor Type of


External Analog 2" is set to VOLTAGE, the unit of this parameter is V; if "Sensor
Type of External Analog 2" is set to CURRENT, the unit of this parameter is A.

Upper limit of extended output analog signal 3. If "Sensor Type of External


Analog 3" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of
External Analog 3" is set to CURRENT, the unit of this parameter is A.

Lower limit of extended output analog signal 3. If "Sensor Type of External


Analog 3" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of
External Analog 3" is set to CURRENT, the unit of this parameter is A.

Sensor type of extended analog signal 3

Maximum measurement range of extended analog signal 3. If "Sensor Type of


External Analog 3" is set to VOLTAGE, the unit of this parameter is V; if "Sensor
Type of External Analog 3" is set to CURRENT, the unit of this parameter is A.

Minimum measurement range of extended analog signal 3. If "Sensor Type of


External Analog 3" is set to VOLTAGE, the unit of this parameter is V; if "Sensor
Type of External Analog 3" is set to CURRENT, the unit of this parameter is A.

Upper limit of extended output analog signal 4. If "Sensor Type of External


Analog 4" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of
External Analog 4" is set to CURRENT, the unit of this parameter is A.

Lower limit of extended output analog signal 4. If "Sensor Type of External


Analog 4" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of
External Analog 4" is set to CURRENT, the unit of this parameter is A.

Sensor type of extended analog signal 4

Maximum measurement range of extended analog signal 4. If "Sensor Type of


External Analog 4" is set to VOLTAGE, the unit of this parameter is V; if "Sensor
Type of External Analog 4" is set to CURRENT, the unit of this parameter is A.

Minimum measurement range of extended analog signal 4. If "Sensor Type of


External Analog 4" is set to VOLTAGE, the unit of this parameter is V; if "Sensor
Type of External Analog 4" is set to CURRENT, the unit of this parameter is A.

Whether it is a SoLSA exclusive access cell. If it is a SoLSA exclusive access cell,


only the MS subscribing the Localised Service Area (LSA) can access this cell.

Threshold for the rate of the number of bad frames to the total number of TRAU
frames. If the bad frame rate exceeds this threshold within the "Period of Mute
Detection Class1", mute speech may be detected. The setting of "Mute
Detection Class 2 Switch" determines whether to perform the class-2 mute
detection.

Received signal strength at an MS expected in power forecast, which helps to


compute the initial transmit power of the BTS

Received signal strength at the BTS expected in power forecast, which helps to
compute the initial transmit power of an MS

ID of the cell. The cell ID cannot conflict with other cell IDs in the BSC6900. The
cells in the BSC are numbered sequentially.
Name of the cell
ID of the cell. The cell ID cannot conflict with other cell IDs in the BSC. The cells
in the BSC are numbered sequentially.
Name of the cell

Index of the cell in the adjacent BSC

Name of the cell in the adjacent BSC


Whether to support the downlink throughput enhancement function of the dual
timeslot cell. When this switch is turned on, the system can allocate the packet
downlink channel of the odd number timeslot of dual timeslot bearer of the
dual timeslot cell.
Whether to enable alarm extension input for the BTS

Whether the network requires an MS to send an extension measurement report

Time interval between two extension measurement reports

Type of an extension measurement report.


There are three types of extension measurement reports: type 1, type 2, and
type 3.
Type 1: No matter whether the BSIC was decoded, the MS sends the network a
measurement report on the six strongest TRXs. The measurement report
contains the received signal level and the decoded BSIC.
Type 2: The MS sends the network a measurement report on the six strongest
TRXs. For the six carriers, the BSIC must be decoded successfully and the NCC
specified by NCC_PERMITTED is carried. The measurement report contains the
received signal level and the decoded BSIC.
Type 3: The MS does not need to decode the BSIC for the TRXs that the
measurement report concerns. The measurement report contains the received
signal level and the interference measurement of one of the concerned TRXs.

Whether a cell is an extension cell.


A double-timeslot extension cell regards an additional TDMA frame as access
delay extension. In theory, the supported TA value is 219, that is, a time delay
of about 120 kilometers.

Whether to send the Dummy message during the deactivated period of the
extended uplink TBF

Interval of sending a paging message or notification message on the FACCH.


Messages on the FACCH are sent in the mode of speech frame stealing. A large
number of consecutive stolen speech frames may affect the voice quality and
even lead to no voice. Therefore, the BTS must control the time interval of
sending a paging or notification message on the FACCH for the purpose of
reducing the impact on the voice quality.

Whether to allow sending notification messages on the FACCH. If the value of


this parameter is YES, an MS engaged in a point-to-point call can receive a
notification message for a group call. You can interrupt the existing call and join
the group call.
Whether to allow sending paging messages on the FACCH. If the value of this
parameter is YES, an MS can receive a paging message on the group call
channel. You can leave the group call and respond to the paging message.
Activation factor switch
If this parameter is set to ON, the BSC assigns the channels in the TRXs of the
cell in a polling manner. Therefore, each TRX has an even chance to be used. In
this way, the connection between the TRX and the RF can be checked without
manual dialing tests.
Penalty signal level imposed on a target cell to which the handover fails due to
congestion or poor radio quality. This penalty helps to prevent the MS from
making a second handover attempt to the target cell.

Continuous speed adjustment

Discrete speed adjustment

Duty ratio-based speed adjustment

Fan adjustment mode

Type of the fan

Fan adjustment mode

Type of the fan box

After a channel request message is received, the type of the channel needs to
be specified. In this case, if the threshold of the load on the TCH in the current
cell is smaller than the Fast Call Setup TCH Usage Threshold and the request
message is not issued during location update or paging, a TCH is preferentially
assigned.

Ring II function switch. The parameter should be set to "YES" when the ring II
function is enabled.

Whether to enable the memory self-check and self-healing function


If the parameter is set to "YES", it indicates that some data packets are
discarded to ensure the basic functions of the BTS are not affected when the FE
port is overloaded. After the port is not overloaded, the flow control is stopped.
Whether to send and process the flow control frame on the physical layer. The
setting of this parameter must be negotiated with that on the interconnected
side.
Threshold for stopping RSL flow control. If the occupancy of the LAPD queue is
less than this threshold, the BSC6900 stops flow control.
Flow control parameter index

Flow control parameter index


Flow control parameter index
Flow control parameter index

Flow control parameter index

Flow control parameter index

Flow control parameter index

Cabinet No. of the parent BTS

Cabinet No. for the port of the father BTS


Threshold for starting RSL flow control. If the occupancy of the LAPD queue is
greater than this threshold, the BSC6900 starts flow control.
CRC verification mode of PPP link.

CRC verification mode of MP link.


Flow control switch. Other switches are valid only when "Flow control switch" is
"ON".

Float charging voltage. Float charging compensates the discharged capacity of


the battery so that the battery can be charged to full voltage indefinitely. The
value of this parameter is slightly lower than the even charging voltage. See
the vendor specification for the setting of this parameter.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Input mode of the BA lists.


AUTO: In this mode, the system fills in the BA1 and BA2 lists according to
neighboring relations of cells.
MANU: In this mode, you can maintain the BA tables by yourself. If the
neighboring relations of cells are changed, for example, after a neighboring cell
is added or deleted, you must maintain the BA1 and BA2 lists by yourself.
This parameter indicate whether to generate the FDD BA2 table automatically
according to neighbor cell relations or to input the FDD BA2 table manually

Offset of a FDD cell report.


When the priority of a 3G cell is sequenced, the value of this parameter be
added to the receive level of the 3G cell in the measurement report.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
7: 42 dB

Threshold of a FDD cell report.


When the receive level value in the measurement report of a 3G cell exceeds
the value of this parameter, the measurement report takes effect. After the
valid measurement report is filtered, the 3G cell joins the cell priority sequence.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
6: 36 dB
7: positive infinity

Diversity indication of a 3G cell. This parameter indicates whether the transmit


diversity mode on the common channel in a cell is activated.0 means No,1
means Yes.
Downlink frequency number that an MS in the connected mode retrieves from
the 3G neighboring cell list. The numbers are sent through system message
2QUATER/MI. The value ranges of frequency numbers vary with corresponding
band reporting.
Minimum Ec/No of the 3G FDD cell candidate

Number of UTRAN FDD cells that should be included in measurement report

This parameter specifies one of the parameters for FDD cell reselection.
A FDD cell becomes a candidate cell if all the following conditions are met for
five consecutive seconds:
1.Receive level of the FDD cell > Average receive level of the current serving
cell + "FDD Q offset";
The FDD cell meets the following condition in the case of any neighboring 2G
cell: Receive level of the FDD cell > Receive level of any neighboring 2G cell +
"FDD Q offset";
2. Ec/No of the FDD cell > "FDD Qmin" - "FDD Qmin Offset";
3. Receive level of the FDD cell > "RSCP Threshold";
If multiple FDD cells meet the preceding conditions, the MS reselects the cell
with the strongest receive level.
See 3GPP TSs 45.008 and 25.304.
The values of this parameter correspond to the following decibel values:
0: -20 dB,
1: -6 dB,
2: -18 dB,
3: -8 dB,
4: -16 dB,
5: -10 dB,
6: -14 dB,
7: -12 dB.

Offset of the minimum threshold for Ec/No during a FDD cell reselection.
A FDD cell becomes a candidate cell if all the following conditions are met for
five consecutive seconds:
1.Receive level of the FDD cell > Average receive level of the current serving
cell + "FDD Q offset";
The FDD cell meets the following condition in the case of any neighboring 2G
cell: Receive level of the FDD cell > Receive level of any neighboring 2G cell +
"FDD Q offset";
2. Ec/No of the FDD cell > "FDD Qmin" - "FDD Qmin Offset";
3. Receive level of the FDD cell > "RSCP Threshold";
If multiple FDD cells meet the preceding conditions, the MS reselects the cell
with the strongest receive level.
See 3GPP TSs 45.008 and 25.304.

This parameter specifies one of the thresholds of the signal level for 3G cell
reselection.
A FDD cell becomes a candidate cell if all the following conditions are met for
five consecutive seconds:
1.Receive level of the FDD cell > Average receive level of the current serving
cell + "FDD Q offset";
The FDD cell meets the following condition in the case of any neighboring 2G
cell: Receive level of the FDD cell > Receive level of any neighboring 2G cell +
"FDD Q offset";
2. Ec/No of the FDD cell > "FDD Qmin" - "FDD Qmin Offset";
3. Receive level of the FDD cell > "RSCP Threshold";
If multiple FDD cells meet the preceding conditions, the MS reselects the cell
with the strongest receive level.
See 3GPP TSs 45.008 and 25.304.
The values of this parameter correspond to the following decibel values:
0: - (always select a cell if acceptable)
1: -28 dB,
2: -24 dB,
...
15: 28 dB.

This parameter specifies whether Ec/No or RSCP is used for the measurement
report on a FDD cell. Ec/No stands for the signal-to-noise ratio. RSCP stands
for the received signal code power.

Minimum level threshold of UTRAN cell reselection. During the cell reselection
decision from a GSM cell to a FDD cell, this parameter is used to calculate the
RSCP threshold of the target cell.
A FDD cell becomes a candidate cell if all the
following conditions are met for five consecutive seconds:
1.Receive level of the FDD cell > Average receive level of the current serving
cell + "FDD Q offset";
The FDD cell meets the following condition in the case of any neighboring 2G
cell: Receive level of the FDD cell > Receive level of any neighboring 2G cell +
"FDD Q offset";
2. Ec/No of the FDD cell > "FDD Qmin" - "FDD Qmin Offset";
3. Receive level of the FDD cell > "RSCP Threshold";
If multiple FDD cells meet the preceding conditions, the MS reselects the cell
with the strongest receive level.
See 3GPP TSs 45.008 and 25.304.
The values of this parameter correspond to the following decibel values:
0 = -114 dBm,
1 = -112 dBm,
2 = -110 dBm,
...
14 = -86 dBm,
15 = -84 dBm.

Minimum RSCP of the 3G FDD cell candidate

Scrambling code of a 3G cell, used for distinguishing MSs or cells. Scrambling


codes are used after spreading. Therefore, the bandwidth of a signal is not
changed. Instead, signals from different sources are differentiated. Scrambling
prevents multiple transmitters from using the same code word for spreading.
On the uplink, the scrambling function is used for differentiating MSs. On the
downlink, the function is used for differentiating cells.
Number of CPU usage sampling times for fast judgment. The value of this
parameter must be of half size of "Filter window" or smaller.
Whether the BTS reports the frame erase ratio in a measurement report or
preprocessed measurement report

If the FER carried in the measurement report (MR) received is lower than or
equal to "FER threshold 1", the value of "FER 0 and Quality Level N" is
incremented by one. If the FER in the MR received is greater than "FER
threshold 1" but meanwhile lower than or equal to "FER threshold 2", the value
of "FER 1 and Quality Level N" is incremented by one.
If the FER carried in the MR received is greater than "FER threshold 2" but
meanwhile lower than "FER threshold 3", the value of "FER 2 and Quality Level
N" is incremented by one.
If the FER carried in the MR received is greater than "FER threshold 3" but
meanwhile lower than "FER threshold 4", the value of "FER 3 and Quality Level
N" is incremented by one.
If the FER carried in the MR received is greater than "FER threshold 4" but
meanwhile lower than "FER threshold 5", the value of "FER 4 and Quality Level
N" is incremented by one.
If the FER carried in the MR received is greater than "FER threshold 5" but
meanwhile lower than "FER threshold 6", the value of "FER 5 and Quality Level
N" is incremented by one.
If the FER carried in the MR received is greater than "FER threshold 6" but
meanwhile lower than "FER threshold 7", the value of "FER 6 and Quality Level
N" is incremented by one.
If the FER carried in the MR received is greater than "FER threshold 7", the
value of "FER 7 and Quality Level N" is incremented by one.

This parameter specifies the frequency hopping mode of a cell. When this
parameter is set to "NO_FH", all the TRXs of the cell do not join in frequency
hopping. When this parameter is set to "BaseBand_FH", the cell is in baseband
frequency hopping mode. In this case, there can be TRXs that do not join in
frequency hopping on the cell. When this parameter is set to "RF_FH", the cell
is in RF frequency hopping mode. In this case, there can be TRXs that do not
join in frequency hopping on the cell. When this parameter is set to
"Hybrid_FH", the cell is in hybrid frequency hopping. In this case, some TRXs on
the cell must join in baseband frequency hopping, some cells on the cell must
join in RF frequency hopping, and some cells on the cell must not join in
frequency hopping.

Path of the target file


The name of the file cannot contain the path and suffix. The suffix is
automatically added. The name of the file is composed of English letters,
numerals, and common symbols, and the characters (@, #, !, %, ^, &, *,
[, ], /, \, ', and ") cannot appear in the name of the file.

Name of the backup file. The file name is composed of English letters,
numerals, and common symbols, and the characters (@, #, !, %, ^, &, *,
[, ], /, \, ', and ") cannot appear in the file name.
Path to save the exported file. The path must be a valid path on the OMU
server. If the OMU runs the LINUX system, the input path must start with the
symbol "/" or "\", for example, "/mml". If the OMU runs the WINDOWS system,
the input path can be a full path (for example, "D:\mml") or a relative path (for
example, "/mml"). If the relative path is used, the root directory is same as that
of the OMU installation directory. That is, if the OMU software is installed in disk
D, the exported file is saved in "D:/mml".

Type of the alarm log file to be exported


Maximum number of former values when the receive level of the serving cell or
the receive level of the neighbor cell is filtered. The greater the value, the
greater the weight of the former receive levels; otherwise, the greater the
weight of the later receive levels.
Execution result.
If you select "FALSE", only the records of failed operations are displayed. If you
select "TRUE", only the records of successful operations are displayed. If this
parameter is not specified, all the records are displayed.

Whether to enable 0.2 dB downlink power control. This power control function
improves the power control precision.

Whether to start the fire-extinguishing equipment of the BTS.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
This parameter specifies the static Abis resource load threshold. If the static
Abis resource load is less than the static Abis resource load threshold, the TCHF
is preferentially allocated. Otherwise, whether the TCHF or the TCHH should be
preferentially allocated is determined by the dynamic Abis resource load.
Time threshold for delaying the report of a clear alarm. If the alarm recurs
within the time specified by this parameter after it is cleared, the clear alarm is
not reported. Otherwise, the clear alarm is reported. If this parameter is set to
0, the clear alarm is reported immediately when the alarm is cleared.
Time threshold for delaying the report of an alarm. If the alarm is cleared within
the time specified by this parameter, the alarm is not reported. Otherwise, the
alarm is reported. If this parameter is set to 0, the alarm is reported
immediately when the alarm occurs.

Whether to enable the filtering of the intermittent alarms. If the value of this
parameter is "DISABLE", "Flash Statis Alarm Raise Time Window" and "Flash
Statis Alarm Clear Time" are invalid.
Time window for observing the clearance of the intermittent alarms. In this time
window, the BTS statistical alarm is cleared if the occurrence of the intermittent
alarm meets the related threshold.
Time window for observing the intermittent alarms generated during the
statistical period. In this time window, the BTS statistical alarm is reported if the
occurrence of the intermittent alarm meets the related threshold.

Service timeslot assignment mode for the BTS. If this parameter is set to
FIX_16K_ABIS, the BSC6900 assigns a fixed Abis transmission timeslot to a TCH.
If this parameter is set to FLEX_ABIS, the BSC6900 assigns an Abis transmission
timeslot dynamically to a TCH (except the static PDCH) to increase the resource
utilization. If this parameter is set to SEMI_ABIS, the BTS to which a TCH
belongs assigns a fixed Abis transmission timeslot to the TCH while the upperlevel BTS set to FLEX_ABIS assigns an Abis transmission timeslot dynamically to
the TCH. This mode applies where old and new BTSs are cascaded. HDLC and IP
BTS is not support this parameter.
Whether to enable the function of Flex mobile allocation index offset (MAIO). In
the tight frequency reuse case of the GSM system, adjacent-channel
interference and co-channel interference easily occur between channels. If the
frequency hopping function and the Flex MAIO function are enabled in a cell,
adjacent-channel or co-channel interference between channels can be reduced
partially.
Whether to enable the function of the Flex training sequence code (TSC). If the
value of this parameter is ON and the BTS supports the Flex TSC function, the
BSS dynamically allocates TSCs to hopping frequencies for improving the
security of calls.
Period of collecting the traffic statistics
Fast flux measurement period. The ratio of the uplink flux to the downlink flux is
calculated at the interval specified by this parameter to determine the current
service priority type.
Logical port flow control switch

Specified port flow control switch

Port flow control switch

Link flow control switch

Link flow control switch


Port flow control switch

One of the nine parameters (filter parameters A1 to A8 and filter parameter B)


used to configure the filter for determining whether the received signal level
drops rapidly. The computation formula is as follows:
C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)
If C1(nt) is less than B and C(nt) is less than the threshold for edge handover,
the signal level is considered dropping rapidly.
In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the
negative of filter parameter B. C(nt) indicates the received signal level in the
uplink measurement report of the serving cell received at time nt.
Setting the filter helps to configure the maximum allowed signal level drop
degree.

One of the nine parameters (filter parameters A1 to A8 and filter parameter B)


used to configure the filter for determining whether the received signal level
drops rapidly. The computation formula is as follows:
C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)
If C1(nt) is less than B and C(nt) is less than the threshold for edge handover,
the signal level is considered dropping rapidly.
In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the
negative of filter parameter B. C(nt) indicates the received signal level in the
uplink measurement report of the serving cell received at time nt.
Setting the filter helps to configure the maximum allowed signal level drop
degree.

One of the nine parameters (filter parameters A1 to A8 and filter parameter B)


used to configure the filter for determining whether the received signal level
drops rapidly. The computation formula is as follows:
C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)
If C1(nt) is less than B and C(nt) is less than the threshold for edge handover,
the signal level is considered dropping rapidly.
In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the
negative of filter parameter B. C(nt) indicates the received signal level in the
uplink measurement report of the serving cell received at time nt.
Setting the filter helps to configure the maximum allowed signal level drop
degree.

One of the nine parameters (filter parameters A1 to A8 and filter parameter B)


used to configure the filter for determining whether the received signal level
drops rapidly. The computation formula is as follows:
C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)
If C1(nt) is less than B and C(nt) is less than the threshold for edge handover,
the signal level is considered dropping rapidly.
In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the
negative of filter parameter B. C(nt) indicates the received signal level in the
uplink measurement report of the serving cell received at time nt.
Setting the filter helps to configure the maximum allowed signal level drop
degree.

One of the nine parameters (filter parameters A1 to A8 and filter parameter B)


used to configure the filter for determining whether the received signal level
drops rapidly. The computation formula is as follows:
C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)
If C1(nt) is less than B and C(nt) is less than the threshold for edge handover,
the signal level is considered dropping rapidly.
In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the
negative of filter parameter B. C(nt) indicates the received signal level in the
uplink measurement report of the serving cell received at time nt.
Setting the filter helps to configure the maximum allowed signal level drop
degree.

One of the nine parameters (filter parameters A1 to A8 and filter parameter B)


used to configure the filter for determining whether the received signal level
drops rapidly. The computation formula is as follows:
C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)
If C1(nt) is less than B and C(nt) is less than the threshold for edge handover,
the signal level is considered dropping rapidly.
In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the
negative of filter parameter B. C(nt) indicates the received signal level in the
uplink measurement report of the serving cell received at time nt.
Setting the filter helps to configure the maximum allowed signal level drop
degree.

One of the nine parameters (filter parameters A1 to A8 and filter parameter B)


used to configure the filter for determining whether the received signal level
drops rapidly. The computation formula is as follows:
C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)
If C1(nt) is less than B and C(nt) is less than the threshold for edge handover,
the signal level is considered dropping rapidly.
In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the
negative of filter parameter B. C(nt) indicates the received signal level in the
uplink measurement report of the serving cell received at time nt.
Setting the filter helps to configure the maximum allowed signal level drop
degree.

One of the nine parameters (filter parameters A1 to A8 and filter parameter B)


used to configure the filter for determining whether the received signal level
drops rapidly. The computation formula is as follows:
C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)
If C1(nt) is less than B and C(nt) is less than the threshold for edge handover,
the signal level is considered dropping rapidly.
In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the
negative of filter parameter B. C(nt) indicates the received signal level in the
uplink measurement report of the serving cell received at time nt.
Setting the filter helps to configure the maximum allowed signal level drop
degree.

Trend of the received signal level of the cell during a period. This parameter
helps to configure the filter for determining whether the received signal level
drops rapidly. If this parameter is higher, a more rapid signal level drop is
required to trigger the handover due to rapid signal level drop.

This parameter determines whether the BSC transfers the LLC PDUs in the
buffer to the target cell or discards these LLC PDUs in the buffer when receiving
the FLUSH-LL message from the SGSN.

Maximum transmit power level of MSs. As one of the cell reselection


parameters in system message 3, this parameter is used to control the transmit
power of MSs. For details, see GSM Rec. 05.05.
In a GSM900 cell, the maximum power control level of an MS ranges from 0 to
19, corresponding respectively to the following values (unit: dBm): 43, 41, 39,
37, 35, 33, 31, 29, 27, 25, 23, 21, 19, 17, 15, 13, 11, 9, 7, and 5.Generally, the
maximum transmit power supported by an MS is level 5 (corresponding to 33
dBm). The minimum transmit power supported by an MS is level 19
(corresponding to 5 dBm). Other transmit power levels are reserved for highpower MSs.
In a GSM1800 or GSM1900 cell, the maximum power control level of an MS
ranges from 0 to 31, corresponding respectively to the following values (unit:
dBm): 30, 28, 26, 24, 22, 20, 18, 16, 14, 12, 10, 8, 6, 4, 2, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0, 0, 0, 0, 36, 34, and 32. Generally, the maximum transmit power
supported by an MS is level 0 (corresponding to 30 dBm). The minimum
transmit power supported by an MS is level 15 (corresponding to 0 dBm). Other
transmit power levels are reserved for high-power MSs.

Type of the FMUA board

Name of the file. The following special characters are not allowed in the file
name: \, /, :, *, ?, ", <, >, |, (, ), &, and $.

Name of the electronic label file


Name of the specified file. By default, the file is in the OMU active-area path
\ftp\license folder.
Name of the file

Name of the file

File name of the software to be downloaded

File name of the software to be downloaded.The file name must be with the
extension of *.zip.If you do not enter the file name, all the valid files in the
directory are downloaded. These valid files are extracted from the patch
package.
Switch specifying whether to allow the downlink EGPRS TBF and the uplink
GPRS TBF to share the same channel. On: allow the downlink EGPRS TBF and
the uplink GPRS TBF to share the same channel; Off: prohibit the downlink
EGPRS TBF and the uplink GPRS TBF sharing the same channel.
Length of the timer for determining the intermittent disconnection of the SS7
link to the DPC. When the time of SS7 link disconnection exceeds the period
specified by the timer, the BSC performs corresponding operations, including
clearing the calls carried on the disconnected link. Otherwise, the system does
not perform any operation.

Time limit for restraining the noise level

Whether the forced phase-2 access is allowed for the MSs

Whether to forcibly enable the EFR function. When this parameter is set to YES,
if both the MS and the BSC6900 support the enhanced full rate (EFR), the
BSC6900 forcibly enables the EFR function even if the MSC does not support
the function.

Whether an MS is forced to send a Handover Access message, which is


indicated by an information element in the handover command.
Port No. of the father BTS connected with the BTS

Number of the port for the destination father BTS

Maximum time of delay for multiplexing. This parameter is used for the system
to send the multiplexed data. If the time for buffering the data exceeds this
value, the system does not wait for the multiplexing of other packets. In this
way, the overlong delay can be prevented.
Whether to generate the frequency and BSIC by using the automatic
optimization algorithm
If this switch is on, it indicates that the frequency and BSIC are generated
automatically. If this switch is off, it indicates that the data must be configured
manually.
If this switch is on, it indicates that the frequency and BSIC are generated
automatically. If this switch is off, it indicates that the data must be configured
manually.
MP segment size,the length of packet should be bigger or equel with it.

Frame offset. The frame offset technology arranges the frame numbers of
different cells under the same BTS to be different from one another by one
frame offset. Thus, the FCH and SCH signals of neighboring cells do not appear
in the same frame, which is helpful for the coding of an MS. If the value of this
parameter is 0, the cell is not offset. If the value is 255, this parameter is not
sent. If the parameter is set to a value except for 0 and 255, the handover of
the cell must be changed from the synchronous mode to the asynchronous
mode. For BTS3001C, BTS3X, BTS3002C, and double-transceiver BTSs, the
frame offset can be predicted according to the value of this parameter.

Frame offset of the BTS clock

Whether the downlink discontinuous transmission (DTX) function is enabled for


full rate (FR) calls. This function is also restricted by the DTX switch in the MSC.
If the MSC allows the downlink DTX for calls and the value of this
parameter(FRDLDTX) is YES, the downlink DTX is enabled for FR calls of cells.

Frequency of the TRX


Based on different requirements, you can set different time points for the
scheduled task.
Seven time modes are available:
1. ONTIME: When this parameter is set to "ONTIME", the command is executed
once only at the specified time point.
2. DAILY_T: When this parameter is set to "DAILY_T", the command is executed
every day. You can also set up to five time points for executing the command in
the day. The default execution interval is one day.
3. DAILY_C: When this parameter is set to "DAILY_C", the command is executed
every day. You can set the start time and end time in the day in which the
command is executed. You can also set the time interval for executing the
command in the day. The default execution interval is one day and the default
time interval is 30 minutes.
4. WEEKLY_T: When this parameter is set to "WEEKLY_T", the command is
executed every week. You can set the day in which the command is executed.
You can also set up to five time points for executing the command in the day.
The default execution interval is one week.
5. WEEKLY_C: When this parameter is set to "WEEKLY_C", the command is
executed every week. You can set the day in which the command is executed.
You can also set the start time and end time in the day in which the command
is executed, and set the time interval for executing the command in the day.
The default execution interval is one week and the default time interval is 30
minutes.
6. MONTHLY_T: When this parameter is set to "MONTHLY_T", the command is
executed every month. You can set the day in which the command is executed.
You can also set up to five time points for executing the command in the day.
The default execution interval is one month.
7. MONTHLY_C: When this parameter is set to "MONTHLY_C", the command is
executed every month. You can set the day in which the command is executed.
You can also set the start time and end time in the day in which the command
is executed, and set the time interval for executing the command in the day.
The default execution interval is one month and the default time interval is 30
minutes.

Time mode used when the log is exported. "ONTIME" indicates the time
between two exact time. "RELATIVE_T" indicates the time before the current
time.
Frequency 1

Frequency 10

Frequency 11

Frequency 12

Frequency 13

Frequency 14

Frequency 15

Frequency 16

Frequency 17

Frequency 18

Frequency 19

Frequency 2

Frequency 20

Frequency 21

Frequency 22

Frequency 23

Frequency 24

Frequency 25

Frequency 26

Frequency 27

Frequency 28

Frequency 29

Frequency 3

Frequency 30

Frequency 31

Frequency 32

Frequency 33

Frequency 34

Frequency 35

Frequency 36

Frequency 37

Frequency 38

Frequency 39

Frequency 4

Frequency 40

Frequency 41

Frequency 42

Frequency 43

Frequency 44

Frequency 45

Frequency 46

Frequency 47

Frequency 48

Frequency 49

Frequency 5

Frequency 50

Frequency 51

Frequency 52

Frequency 53

Frequency 54

Frequency 55

Frequency 56

Frequency 57

Frequency 58

Frequency 59

Frequency 6

Frequency 60

Frequency 61

Frequency 62

Frequency 63

Frequency 64

Frequency 7

Frequency 8

Frequency 9

Whether to enable the automatic frequency correction algorithm. This


parameter is used for the fast-moving handover algorithm. If the parameter is
set to YES, the BTS calculates the speed at which an MS leaves or approaches
it, and sends the BSC6900 the calculated speed in an uplink measurement
report.

Frequency correction parameter. Used for the fast-moving handover algorithm,


the value of this parameter must be translated into a binary number. The value
consists of 16 bit. The most significant bit indicates whether the parameter is
valid. Bits 14 to 8 indicate the level threshold. Bits 7 to 0 indicate the threshold
of the bit error ratio (BER).
The BSC6900 sends this parameter to the BTS, which adjusts the frequency of
an MS according to the value of this parameter.

Frequency band types of the board This parameter is only applicable to the
DDPU/DFCU/DFCB/DCOM/DDPM/DCBM.
The frequency band types for the DTRU, QTRU, DRRU, DRFU, GRRU, MRRU,
GRFU, and MRFU cannot be configured and thus are calculated based on the
selected frequencies such as GSM900, DSC1800, PCS1900,and GSM850. The
parameter value for the other board types is set to 0xFF.

Threshold for load sharing in the 900 MHz frequency band. Assume that an MS
supports multiple sub-bands in the 900 MHz frequency band. If the cell load is
equal to or less than this threshold, the BSC does not consider the priority
levels of the P-GSM, E-GSM, and R-GSM sub-bands during channel assignment.
If the cell load is greater than this threshold, the BSC assigns channels
according to the priority levels of the P-GSM, E-GSM, and R-GSM sub-bands.
That is, if the MS supports the P-GSM, E-GSM, and R-GSM sub-bands and the
cell is configured with the TRXs in the P-GSM, E-GSM, and R-GSM sub-bands,
the BSC assigns the channels in the TRXs of the R-GSM sub-band preferentially.

List of frequency bands


Frequency multiplexing mode in the TRX. To enable a loose frequency
multiplexing mode such as 4x3 multiplexing, set this parameter to LOOSE. To
enable a tight frequency multiplexing mode such as 1x3 or 1x1, set this
parameter to TIGHT.
List of the frequencies to be measured. This parameter is represented as a
character string where the IDs of the TRXs to be measured are separated by &,
such as 1&124&956.
Type of a scanning result in the period from the start of a frequency scanning
task to the reporting of the scanning result.
Frequency scanning refers to the scanning of an uplink receive level of a cell
frequency. The scanning result reflects the strength of frequency signals
received by the cell.

Whether to enable the edge handover algorithm. When an MS makes a call at


the edge of a cell, the call may drop if the received signal level is too low. To
avoid such a call drop, the edge handover algorithm is involved. When the
uplink signal level of the serving cell is less than "Edge HO UL RX_LEV
Threshold" or the downlink signal level of the serving cell is less than "Edge HO
DL RX_LEV Threshold", the edge handover is triggered.

Whether the uplink DTX function is enabled for FR calls. For details, see GSM
Rec. 05.08. Uplink DTX is not restricted by the MSC. If this parameter is set to
May_Use, the MS can use DTX. If this parameter is set to Shall_Use or
Shall_Not_Use, the MS cannot use DTX.

Slot No. of the father BTS

Slot No. for the port of the father BTS

Subrack No. of the father BTS

Subrack No. for the port of the father BTS

Type of the file used for saving exported logs

Activation factor table index


Activation factor table index
Activation factor table index

ATCB difference between the overlaid and underlaid subcells

Duration of the handover from full rate to half rate. If the cell load is greater
than the preset threshold, the calls that meet the conditions for the handover
from full rate to half rate are handed over from full rate to half rate in this
duration.

According to the P/N rule, if the conditions for the handover from full rate to
half rate are met for P seconds within N seconds, the handover is triggered.
This parameter specifies the number P.

Path loss difference between the overlaid and underlaid subcells

Period of the handover from full rate to half rate. If the cell load is greater than
the preset threshold, the calls that meet the conditions for the handover from
full rate to half rate are handed over in "H-F Ho Duration". This parameter
specifies the bandwidth to be handed over at each hierarchy level.

According to the P/N rule, if the conditions for the handover from full rate to
half rate are met for P seconds within N seconds, the handover is triggered.
This parameter specifies the number N.

If the available forward bandwidth is less than or equal to this value, the
forward congestion alarm is emitted and forward congestion control is
striggered.
If the available forward bandwidth is greater than this value, the forward
congestion alarm is cleared and forward congestion control is stopped.
If the ratio of available forward bandwidth is greater than this value, the
forward congestion alarm is cleared and forward congestion control is stopped.
If the ratio of available forward bandwidth is less than or equal to this value,
the forward congestion alarm is emitted and forward congestion control is
triggered.
If the available forward bandwidth is greater than this value, the forward
overload congestion alarm is cleared and forward overload control is stopped.
If the ratio of available forward bandwidth is greater than this value, the
forward overload congestion alarm is cleared and forward overload control is
stopped.
If the available forward bandwidth is less than or equal to this value, the
forward overload congestion alarm is emitted and forward overload control is
triggered.
If the ratio of available forward bandwidth is less than or equal to this value,
the forward overload congestion alarm is emitted and forward overload control
is triggered.
Ratio of reserved forward bandwidth for handover user
Reserved forward bandwidth for handover user
If the load balance between a 2G cell and a 3G cell is greater than the
threshold, load balance is triggered.
Coefficient used to modulate the load level of a 2G system so that the load
level of the 2G system can be compared with that of a 3G system.
G711 Mode. A/U law configuration, 0-A law (default), 1-U law
Expected signal receiving strength on the BTS side when GPRS dynamic power
control is implemented
End time for collecting the offset information

Cell load threshold for collecting the offset information. If the load threshold is
exceeded, the offset information is not collected.
Whether to collect the offset information

Start time for collecting the offset information

Obtains the QoS parameter from the Aggregate BSS QoS Profile (ABQP) of
packet flow context (PFC) when the MS and the network support the PFC;
obtains the QoS parameter from the uplink request originated by the MS or the
DL UNITDATA of the SGSN. GBR: guaranteed bit rate.
This parameter specifies whether to enable the VGCS/VBS check function. If the
BSS works abnormally, the BTS may periodically send notification messages
even if VGCS/VBS is over. In this case, an MS responds continuously but cannot
access this VGCS/VBS TCH.
Format of the geographic coordinates. The values include "DEG" and "SEC".
Whether the assignment of channels in overlaid subcells is enabled for the
VGCS service in the case of underlaid subcell congestion. Generally, only the
channels in underlaid subcells can be assigned to the VGCS service.
Whether direct preemption of the channels of other services is enabled for the
VGCS service. If the value of this parameter is NO, a handover is performed for
the call whose channel is preempted. If the value is YES, calls on the
preempted channel are directly released.
Global routing management switch. If this switch is turned on, the IP addresses
in the controlled range cannot be in the same network segment.
Delay of transmit diversity when GMSK is used. Generally, the parameter is
applicable to general fading environments. In this case, the transmit diversity
can obtain the gain of 3 dB to 5 dB. The fading degrees, however, vary with
environments. For a fixed delay, different UEs may obtain different gains. In
addition, a fixed delay may have negative impacts on some codes of the EDGE
service. Therefore, the delay of transmit diversity must be configurable and can
be set for GMSK and 8PSK respectively.

Whether the currently cell supports the GPRS

Whether the current cell supports GPRS

Hysteresis value of the cell in the same routing area. When the MS in the ready
state reselects a cell, if the original cell and the target cell are in the same
routing area, the C2 values of the two cells at the border of the cell are quite
different due to radio channel fading. As a result, the MS frequently reselects
cells. Frequent cell reselection can lead to increase of signaling traffic,
inefficient use of radio resources, decrease of MS data transmission rate, and
thus reducing the network service quality. The cell reselection hysteresis
parameter is introduced. The signal level of the adjacent cell in the same area
must be greater than that of the local cell. The difference of the signal level
must be greater than the value of the cell reselection hysteresis parameter.
Otherwise, the MS cannot reselect a cell. The greater the GPRS cell
reselection hysteresis value, the harder to start cell reselection.

EGPRS priority type of the channel


If this parameter is set to GPRS, the EDGE MSs cannot use this channel.
If this parameter is set to EGPRSNORCH, the GPRS and EDGE MSs can use this
channel at the same priority.
If this parameter is set to EGPRSPRICH, the EDGE MSs have the priority to use
this channel.
If this parameter is set to EGPRSSPECH, only the EDGE MSs can use this
channel.
If this parameter is set to NONGPRS, this parameter becomes invalid.

Threshold of hierarchical cell structure (HCS) signal strength. The MS calculates


the C31 according to the signal strength and its threshold and selects the
adjacent cell during cell reselection.

Timer used when the MS calculates the C2 (used to evaluate the channel
quality during cell reselection). The time information is transmitted in the
system message of each cell.

Used for the GPRS transmission quality statistics. When the transmission
quality threshold is exceeded, the transmission quality is regarded
deteriorated.
This parameter is used to prevent repeated cell reselection of a fast moving MS.
The MS does not select this cell when the duration of maintaining the BCCH
signal channel strength does not reach the penalty time.
Synchronization clock adopted when two satellite cards are used together.
GPS:Trace GPS only. GLONASS:Trace GLONASS only. GPSGlonass:Trace GPS and
GLONASS.
Period for reporting GPS data
Whether to allow hierarchical access and to reserve resources for high-priority
MSs
Number of the VGCS call that the BTS originates in the timeslot in the TRX in
fallback mode. This parameter is represented in decimal, such as 10000569. If
this parameter is set to 100000000, the channel is not configured with any
fixed group call.
Number of the VGCS call that the BTS originates in the timeslot in the TRX in
fallback mode. This parameter is represented in decimal, such as 10000569. If
this parameter is set to 100000000, the channel is not configured with any
fixed group call.
Index of the BSC Node Redundancy Group. It identifies a BSC redundancy
group. The BSC node redundancy is a function through which two BSCs form a
redundancy group. The two BSCs in a redundancy group work in 1+1 load
sharing mode. When one BSC in a redundancy group is faulty or all the
signaling links on the A interface are faulty, the other BSC in this group takes
over the voice and data services. In this manner, the reliability and robustness
of the network are improved, the service disruption time due to BSC failure is
reduced, and the quality of service (QoS) is improved.

Name of the BSC Node Redundancy Group


Maximum number of secondary links that are released in batches when the
Abis resource preemption occurs on the Abis interface
Transport resource group number
Type of the transport resource group
Geographical coverage of a simple cell broadcast message. You can run "DSP
GSMSCB" to query and obtain the information.
This parameter, "Code", and "Update" uniquely specify a cell broadcast
message.
Ratio of bandwidth occupied by the CS service in the GSM
Standard priority for GSM CS(Circuit Switched) high-priprity MSs. 15 is the
highest priority.
Number of neighboring cells that meet the following conditions: If "MBR" is
indicated in a system message, the MS reports the number of neighboring cells
at each frequency band. If the MS reports the number of neighboring cells at
the same frequency band of the serving cell, it can report a maximum of the
value of this parameter.
These neighboring cells must meet the following requirements:
1. The receive levels of the neighboring cells must be higher than "900
Reporting Threshold" or "1800 Reporting Threshold".
2. The BSIC of a neighboring cell must be valid.
3. The signals of the neighboring cells must be the strongest among all the
neighboring cells at the same frequency band.
Whether to support the cell reselection from the GSM network to the TD
network in the packet transmission mode

Packet type against the ICMP attack

When the BTS is accessed from the public network, the BTS security network IP
address must be configured.
IP address of the BTS security gateway. This parameter needs to be configured
when the BTS connects to the BSC6900 through the public network.

Whether to support CS half rate data services

ATCB difference between the overlaid and underlaid subcells

Duration of the handover from half rate to full rate. If the cell load is less than
the preset threshold, the calls that meet the conditions for the handover from
half rate to full rate are handed over from half rate to full rate in this duration.

According to the P/N rule, if the conditions for the handover from half rate to
full rate are met for P seconds within N seconds, the handover is triggered.
This parameter specifies the number P.

Path loss difference between the overlaid and underlaid subcells

According to the P/N rule, if the conditions for the handover from half rate to
full rate are met for P seconds within N seconds, the handover is triggered.
This parameter specifies the number N.

Whether the tower-top amplifier is installed on antenna tributary 1.

Whether the tower-top amplifier is installed on antenna tributary 2.

Heartbeat interval when the SCTP server is idle


Number of the cabinet where the main board of the RXU chain or ring is
located.

According to the P/N rule, if the conditions for the handover to a different micro
cell due to fast movement are met in P of N measurement reports, the
handover is triggered.
This parameter specifies the number P.

According to the P/N rule, if the conditions for the handover to a different micro
cell due to fast movement are met in P of N measurement reports, the
handover is triggered.
This parameter specifies the number N.
Threshold for interrupting the power supply to the TRXs. If the BTS works with
the battery power supply, when the battery voltage is less than this threshold,
the BTS interrupts the power supply to the TRXs to protect the lower-level BTSs
from being affected.
Threshold for interrupting the power supply to the TMU. If the BTS works with
the battery power supply, when the battery voltage is less than this threshold,
the BTS interrupts the power supply to the TMU.
Type of a high frequency type supported by the BSC6900,
Frequencies on DCS1800: 512-885
Frequencies on PCS1900: 512-810
Full rate TCHs are assigned preferentially to the MSs with priority levels equal to
or less than this threshold, except when the MSs request only half or full rate
TCHs.
This parameter specifies whether the MS with priority level 1 directly releases
the preempted call. When this parameter is set to Yes, the access delay of MSs
with high priorities is ensured and the access rate of MSs with high priorities is
increased, but the preempted call drops.

Whether to enable the priority-based channel assignment algorithm

Whether to enable load power-off against high temperature

Whether to consider history priority records during channel assignment.


If this parameter is set to YES, the history priority records are considered. If this
parameter is set to NO, the history priority records are not considered.

Maximum History Password Numbers.

Whether the cell supports the MS with the DTM multi-timeslot capability

Whether to assign a channel in the overlaid or underlaid subcell in the case of


the intra-BSC incoming handover to the concentric cell.
If this parameter is set to SysOpt, the measured BCCH of the target cell is
included in the intra-BSC inter-cell handover request message. Then, the BSC
compares the measured value with "RX_LEV Threshold" to choose the preferred
subcell. During this course, the BSC does not consider "RX_LEV Hysteresis".
If this parameter is set to OSubcell, a channel in the overlaid subcell is assigned
preferentially.
If this parameter is set to USubcell, a channel in the underlaid subcell is
assigned preferentially.
If this parameter is set to NoPrefer, a channel is assigned simply according to
channel assignment algorithms.
Whether to allow handover between different operators. If the BSC6900
supports RAN sharing, MSs in a cell of this operator can be handed over to a
cell of other operators, or vice versa.

If the downlink received signal level of a neighbor cell is greater than "Min DL
Level on Candidate Cell" plus "Min Access Level Offset", the neighbor cell can
be listed in the candidate cell queue for handover.

If the uplink received signal level of a neighbor cell is greater than "Min UL
Level on Candidate Cell" plus "Min Access Level Offset", the neighbor cell can
be listed in the candidate cell queue for handover.

Type of indexing the target cell

Unique name of the target cell

Whether to use handover algorithm generation 1 or 2 currently

Handover direction forcast switch. When this parameter is set to YES, the
BSC6900 can forecast the handover direction of the call in fast handover so
that the best target cell can be selected for handover.

This parameter indicates P in the P/N rule for MS handover direction forcast.
P/N rule: Among N handovers, the MS is handed over to Class B chain
neighboring cell for successively P times, then the BSC6900 determines that
the MS is moving to the Class B chain neighboring cell.

This parameter indicates N in the P/N rule for MS handover direction forcast.
P/N rule: Among N handovers, the MS is handed over to Class B chain
neighboring cell for successively P times, then the BSC6900 determines that
the MS is moving to the Class B chain neighboring cell.

Fast handover can be triggered only when the downlink level of the serving cell
is less than this parameter.

According to the P/N rule, if the conditions for the handover to a better 3G cell
are met for P seconds within N seconds, the handover is triggered.
This parameter specifies the number P.

According to the P/N rule, if the conditions for the handover to a better 3G cell
are met for P seconds within N seconds, the handover is triggered.
This parameter specifies the number P.

The 3G better cell handover can be triggered only when the Ec/No of a
neighboring 3G cell is greater than this threshold for a period of time.

According to the P/N rule, if the conditions for fast handover are met in P of N
measurement reports, the handover is triggered.
This parameter specifies the number P.

Type of handover in terms of connection transfer between channels or between


cells

Fast handover can be triggered only when the path loss difference between the
serving cell and a neighbor cell on the chain is equal to or greater than this
parameter.

If the cell is an enhanced concentric cell, this parameter with the current
downlink received signal level and "UtoO HO Received Level Threshold"
determines whether to assign a channel in the underlaid subcell to the intraBSC incoming handover to the concentric cell or intra-BSC inter-cell handover.
If the cell is an ordinary concentric cell, this parameter with the current
downlink received signal level, "RX_LEV Threshold", and "RX_LEV Hysteresis"
determines whether to assign a channel in the underlaid subcell to the intraBSC incoming handover to the concentric cell or intra-BSC inter-cell handover.

This parameter specifies whether a 2G cell or to a 3G cell is preferentially


selected as the target cell for handover.
When this parameter is set to Pre_2G_Cell, the BSC
preferentially selects a 2G candidate cell as the target cell for handover.
When this parameter is set to Pre_3G_Cell, the BSC preferentially selects a 3G
candidate cell as the target cell for handover.
When this parameter is set to Pre_2G_CellThres, the BSC
preferentially selects a neighboring 3G cell as the handover target cell if the
receive level of the neighboring 2G cell that ranks the first in the candidate cell
list is equal to or smaller than "HO Preference Threshold for 2G Cell".
Otherwise, the BSC preferentially selects a neighboring 2G cell as the handover
target cell.
An MS cannot be handed over from the underlaid subcell to the overlaid subcell
in this duration after the MS is handed over from the overlaid subcell to the
underlaid subcell successfully.

Index of the frequency hopping data, used for a TRX to locate the frequency
hopping sequence
Logical number of the MA group

Implementation mode of frequency hopping

Whether to enable power boost before handover.


When the receive level of an MS drops rapidly, a handover occurs. In this case,
the BSC6900 cannot adjust the transmit power of the MS and the BTS in time.
The MS may fail to receive a handover command, thus leading to a call drop. If
the value of this parameter is YES (StartUp), the transmit power of the BTS is
adjusted to the maximum before the BSC6900 sends a handover command to
the MS. In addition, the transmit power of the BTS is not adjusted during the
handover for the purpose of ensuring the success of the handover.

If the receive level of the neighboring 2G cell that ranks the first in the
candidate cell list is equal to or smaller than this threshold, the BSC
preferentially selects a neighboring 3G cell as the handover target cell.
Otherwise, the BSC preferentially selects a neighboring 2G cell as the
handover target cell.
If this parameter is set to ON, the channel on a single frequency of an MA group
is allocated to an MS with the non-FH attribute.
Hoping sequence number (HSN) of a hopping antenna group. If the value of this
parameter is 0, the services over a TRX are adjusted to other TRXs in the
hopping antenna group in sequence. If this parameter is set to a value from 1
to 63, the services over a TRX are adjusted to other TRXs in the hopping
antenna group in a pseudo-random manner, that is a disciplinary random
manner.
TRX index that a hopping antenna index corresponds to. A hopping antenna
enables signals of multiple TRXs to switch between several antennas instead of
fixing an antenna for a TRX. This reduces the effect of Rayleigh fading on
signals of some frequencies.
Frequency hopping mode of the TRX. Frequency hopping assists in interference
averaging and frequency diversity.
If this parameter is set to RF_FH, the TX and RX parts of the TRX take part in
the frequency hopping. In this case, the number of hopping frequencies can
exceed the number of TRXs in the cell. If this parameter is set to BaseBand_FH,
each transmitter works at a fixed frequency. That is, the TX part does not take
part in the frequency hopping. The baseband signals are switched for the
frequency-hopping transmission. The RX part, however, takes part in the
frequency hopping.

To avoid ping-pong handover, the received signal of the original serving cell is
decreased by "Quick handover punish value" in "Quick handover punish time"
after fast handover succeeds.

Time for reserving the handover reference for one of the two BSCs that collect
the offset information

The 3G better cell handover is triggered only when the RSCP of a neighboring
3G cell is greater than this threshold for a period of time.

Whether an HO REQ ACK message contains the information element Speech


Version during an SDCCH handover. If a signaling channel handover between
BSCs fails, the value of this parameter may need to be adjusted.

According to the P/N rule, if the conditions for the handover to a better 3G cell
are met in P of N measurement reports, the handover is triggered.
This parameter specifies the number N.

According to the P/N rule, if the conditions for the handover to a better 3G cell
are met in P of N measurement reports, the handover is triggered.
This parameter specifies the number N.

According to the P/N rule, if the conditions for fast handover are met in P of N
measurement reports, the handover is triggered.
This parameter specifies the number N.

Indicates the host type of the signalling point.


When the BSC node redundancy feature is enabled, the primary BSC and the
secondary BSC each must be configured with a signaling point coded in the
same mode. The host type of the signaling point of the primary BSC is set to
"PRIMHOST", and the host type of the signaling point of the secondary BSC is
set to "SLAVEHOST". When the BSC node redundancy feature is disabled, the
host type of the signaling point of the BSC is set to "SINGLEHOST".

Host type of an IP BTS

Handover threshold during the handovers between cells on different layers or


of different priorities. This value is used to suppress inter-layer ping-pong
handovers.
Inter-layer handover threshold of the serving cell = "Inter-layer HO threshold" "Inter-layer HO Hysteresis";
Inter-layer handover threshold of a neighboring cell = "Inter-layer HO
Threshold" + "Adjacent Cell Inter-layer HO Hysteresis" - 64.

Fast handover can be triggered only when the uplink signal level of the serving
cell is less than this parameter.

Whether to enable the TRX to support antenna hopping


In a GSM cell, the BCCH broadcasts the frequency, frame number, system
information, and paging group. If an MS is in an unfavorable position or the
antenna of the main TRX that carries the BCCH fails, the MS receives poor
broadcast control signals or even cannot receive any broadcast control
message from the BCCH. To avoid such a problem, the antenna hopping
function is involved. With this function, the messages transmitted in the main
TRX that carries the BCCH are also transmitted on the antennas of all the other
TRXs in the cell in turn. This helps the MSs receive quality broadcast control
data. This function can be configured only for dual-frequency BTSs. If this
parameter is set to NONE, the BTS does not support antenna hopping.

Whether to enable the TRX to support antenna hopping


In a GSM cell, the BCCH broadcasts the frequency, frame number, system
information, and paging group. If an MS is in an unfavorable position or the
antenna of the main TRX that carries the BCCH fails, the MS receives poor
broadcast control signals or even cannot receive any broadcast control
message from the BCCH. To avoid such as problem, the antenna hopping
function is involved. With this function, the messages transmitted in the main
TRX that carries the BCCH are also transmitted on the antennas of all the other
TRXs in the cell in turn. This helps the MSs receive quality broadcast control
data. This function can be configured only for dual-frequency BTSs.

The number of the optical port of the main board in the RXU chain or ring.

Maximum priority level of an MS that can use reserved channel resources. If the
priority level of an MS is greater than this parameter, the MS is considered a
low-priority MS. If the priority of an MS is equal to or less than this threshold,
the MS is considered a high-priority MS.
Whether to enable the configuration of power system parameters.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Load power-off voltage threshold.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
This parameter determines whether the BSC6900 supports new establishment
causes of an MS in the initial access request. This parameter does not affect the
half-rate function of cells.

Whether the downlink DTX function is enabled for half rate (HR) calls. This
function is also restricted by the DTX switch in the MSC. If the MSC allows the
downlink DTX for calls and the value of this parameter(HRDLDTX) is YES, the
downlink DTX is enabled for HR calls of cells.

Whether to enable the BSC to assign half or full rate channels to MSs according
to the channel seizure ratio in the overlaid and underlaid subcells

Whether the uplink DTX function is enabled for HR calls. For details, see GSM
Rec. 05.08. Uplink DTX is not restricted by the MSC. If this parameter is set to
May_Use, the MS can use DTX. If this parameter is set to Shall_Use or
Shall_Not_Use, the MS cannot use DTX.

Hopping sequence number (HSN), indicating 64 types of frequency hopping


sequences. If this parameter is set to 0, the frequency hopping is performed in
sequence.
If this parameter is set to a value from 1 to 63, the frequency hopping is
performed in a pseudo-random manner, that is a disciplinary random manner.
Number of the slot where the main board of the RXU chain or ring is located.
The slot No. is unique in the same BTS.
Whether dynamic use of HSNs is enabled. If the functions of frequency hopping
and Flex MAIO are enabled in a cell and the value of this parameter is ON,
adjacent-channel interference between channels can be reduced.

Number of the subrack where the main board of the RXU chain or ring is
located. The subrack No. is unique in the same BTS.
Bidirectional Forwarding Detection Hop Type.

If the ambient temperature is higher than "High Temperature Critical Point", the
temperature control system controls the difference between the inlet and outlet
temperatures.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

If the outlet temperature is higher than "High Temperature Critical Point" and
the difference between the outlet temperature and ambient temperature
reaches the value of this parameter, the temperature control system controls
the difference between the inlet and outlet temperatures.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Whether to enable battery power-off against high temperature.

Humidity alarm switch


Upper limit of humidity. When the humidity exceeds the upper limit, a humidity
alarm is reported.
Lower limit of humidity. When the humidity is lower than the lower limit, a
humidity alarm is reported.
When the ambient humidity of the APMU is greater than the value of this
parameter, the BTS reports an overhigh ambient humidity alarm.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
When the ambient humidity is greater than the value of this parameter, the
BTS reports an overhigh ambient humidity alarm.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

When the ambient humidity of the APMU is less than the value of this
parameter, the BTS reports an overlow ambient humidity alarm.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
When the ambient humidity is less than the value of this parameter, the BTS
reports an overlow ambient humidity alarm.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Delay for which the BTS waits to switch on the air conditioner
This timer is started after a connection is established successfully. If a detection
message is not received when this timer expires, the connection will be
released.
Duration in IASU mode
Port number in IASU mode. For the BTS3002C, the port number cannot be set to
"E1PORT3".
Type of the transmission board in IASU mode
This timer is started after a connection is established successfully. When this
timer expires, a detection message will be sent to the peer end.
Minimum C/I ratio that IBCA AMR FR services allow. An idle channel can be
assigned to such a service only when the C/I ratio of the idle channel is greater
than this threshold. In addition, a new call associated with such a service can
be established only when the call does not decrease the C/I ratio of the
established calls to a value less than this threshold.
Minimum C/I ratio that IBCA AMR HR services allow. An idle channel can be
assigned to such a service only when the C/I ratio of the idle channel is greater
than this threshold. In addition, a new call associated with such a service can
be established only when the call does not decrease the C/I ratio of the
established calls to a value less than this threshold.

Whether to enable the IBCA algorithm

Length of the timer for a new call to wait for the measurement report (MR) on
the signaling channel when dynamic measurement of the BA2 list is enabled
during assignment. If this parameter is set to 0, dynamic measurement of the
BA2 list is not enabled during assignment.
Number of measurement reports sampled for averaging path loss. A single
measurement report may not reflect the actual network situations accurately.
Therefore, the BSC needs to average the measured values in several successive
measurement reports to reflect the radio environment.
When the IBCA algorithm is enabled, this parameter is used to calculate the
actual soft blocking threshold of an existing call. The formula is as follows:
Actual soft blocking threshold of an existing call = Configured soft blocking
threshold of an existing call - IBCA Set-up Call Soft Block Threshold Offset.
When the IBCA algorithm is enabled, this parameter is used to calculate the
target CIR of an existing call. The formula is as follows: Target CIR of an existing
call = Target CIR in use + Target CIR Offset of IBCA Set-Up Call.
Difference between uplink and downlink path losses, which is used to estimate
the downlink path loss of a call when the downlink path loss cannot be
computed directly according to a measurement report. This parameter is
configured according to the combined loss and hierarchical dual-antenna gain
(3 dB) of the BTS.
"IBCA Downlink Path Loss Offset" = combined loss of BTS + hierarchical dualantenna gain of BTS (3 dB)
Whether to measure the IBCA neighbor cells of the serving cell dynamically. If
the dynamic measurement is enabled, when a call uses a channel, the BSC
sends the SACCH Modify message to modify the frequencies in the BA2 table in
System Information 5, 5bis, and 5ter to the frequencies at which the IBCA
neighbor cells operate. Thus, the call measures and reports only these
frequencies to the BSC6900.

Length of the timer for a call to measure the path loss in the neighboring cell
with strong interference of the target cell. The call to be handed over needs to
measure the path loss before initiating the handover to the target cell when
dynamic measurement of the BA2 list is enabled during the emergency
handover. When this parameter is set to 0, dynamic measurement of the BA2
list is not enabled in the emergency handover, and the parameter "Wait Time
for Valid MRs in IBCA HO" is invalid.
Whether the IBCA flexible TSC function is enabled. When this parameter is set
to NO, the flexible TSC function is disabled and the configured TSC is used.
When the BTS supports Flex TSC and this parameter is set to YES, the flexible
TSC function is enabled.

Whether the IBCA forced BTS synchronization is allowed. When this parameter
is set to YES, the synchronization procedure is performed even though the BTSs
are insynchronous. When this parameter is set to NO, the existing procedure,
either the synchronization procedure or the out-of-synchronization procedure, is
performed as required. Note that the synchronization status of the IBCA
neighboring cells is determined by the internal software parameters of the IBCA
neighboring cells, that is, if this parameter in IBCA neighboring cells is set to
YES, the IBCA neighboring cells are considered to be always synchronous;
otherwise, the IBCA neighboring cells are considered to be out of
synchronization.

Minimum C/I ratio that IBCA FR/EFR services allow. An idle channel can be
assigned to such a service only when the C/I ratio of the idle channel is greater
than this threshold. In addition, a new call associated with such a service can
be established only when the call does not decrease the C/I ratio of the
established calls to a value less than this threshold.
Length of the timer for a call to wait for other valid MRs after receiving the first
valid MR of the target cell if dynamic measurement of the BA2 list is enabled
during handover. When this parameter is set to 0, the call does not wait for
other MRs after receiving the first MR of the target cell.
Minimum C/I ratio that IBCA HR services allow. An idle channel can be assigned
to such a service only when the C/I ratio of the idle channel is greater than this
threshold. In addition, a new call associated with such a service can be
established only when the call does not decrease the C/I ratio of the established
calls to a value less than this threshold.
In the ICDM matrix algorithm, the signal strength (0-63) is divided into 10
levels. The signal strength that is smaller than or equal to the value of this
parameter is at the initial level.
Whether to enable the ICDM algorithm for the cell. The ICDM algorithm helps to
improve the precision in estimating the path loss of an IBCA neighbor cell and
to increase the efficiency of the IBCA algorithm.

Period of information exchange between the BSC boards. The information helps
to estimate the C/I ratio for the IBCA algorithm.

Adds a specified offset to the downlink target receive level when power control
algorithm III is used to calculate the initial transmit power of a BTS in the IBCA
function

Adds a specified offset to the uplink target receive level when power control
algorithm III is used to calculate the initial transmit power of an MS in the IBCA
function
Adds a specified offset to the downlink target receive quality when power
control algorithm III is used to calculate the initial transmit power of a BTS in
the IBCA function
Adds a specified offset to the uplink target receive quality when power control
algorithm III is used to calculate the initial transmit power of an MS in the IBCA
function
In an IUO cell (or a CoBCCH cell), the path loss of an MS to the serving cell or a
neighboring cell measured on the underlay is used together with this
parameter to estimate the path loss on the overlay. IUO path loss compensation
= Combiner insert loss difference + Path loss difference due to the use of
different antennas + Path loss difference due to different frequency selectivity.
This value is calculated based on the IUO level values measured by field
engineers. When different antennas are used by the overlay and underlay, the
level must be measured at multiple locations.
Determines the MAIO selection method for each timeslot. The Optimal MAIO
policy selects the optimal MAIO being evaluated, while the Random MAIO policy
randomly selects a MAIO out of qualified MAIOs.
The IBCA interference evaluation process only considers the interference of the
strongest N existing calls on the newly-established call being evaluated. This
parameter corresponds to the above-mentioned N.
Indicates whether this neighboring cell is the IBCA neighboring cell of the
serving cell. That is, when a cell is configured as the neighboring cell of the
serving cell, whether the IBCA algorithm considers the interference between
the serving cell and the neighboring cell.

Estimates the receive level of the unmeasured IBCA neighboring cells. When a
consecutive "IBCA Non Measurement Ncell Stat. Num" measurement reports
cover less than six neighboring cells (or the number of the reported
neighboring cells is smaller than that of the actually configured neighboring
cells), this parameter is used to estimate the receive level of the unmeasured
IBCA neighboring cells. The estimated value is "IBCA Pathloss Est of Non. MR
Ncell". Otherwise, the signal strength of the unmeasured IBCA neighboring cells
is the signal strength of the measured neighboring cells (including non-IBCA
neighboring cells) subtracted by "IBCA RxLev Offset".

When the IBCA algorithm is enabled, this parameter is used to calculate the
target CIR of a new call. The formula is as follows: Target CIR of a new call =
Target CIR in use + Target CIR Offset of IBCA New Call
Length of the timer for a call to measure the path loss in the neighboring cell
with strong interference of the target cell. The call to be handed over needs to
measure the path loss before initiating the handover to the target cell when
dynamic measurement of the BA2 list is enabled during the normal handover.
When this parameter is set to 0, dynamic measurement of the BA2 list is not
enabled in the normal handover, and the parameter "Wait Time for Valid MRs in
IBCA HO" is invalid.

Estimates the receive level of the unmeasured IBCA neighboring cells. When a
consecutive "IBCA Non Measurement Ncell Stat. Num" measurement reports
cover less than six neighboring cells (or the number of the reported
neighboring cells is smaller than that of the actually configured neighboring
cells), this parameter is used to estimate the receive level of the unmeasured
IBCA neighboring cells. The estimated value is "IBCA Pathloss Est of Non. MR
Ncell". Otherwise, the signal strength of the unmeasured IBCA neighboring cells
is the signal strength of the measured neighboring cells (including non-IBCA
neighboring cells) subtracted by "IBCA RxLev Offset".

When the IBCA algorithm is enabled and the HSN is not 0, the IBCA priority and
the SDCCH/PDCH priority are divided by this corrected factor respectively to
reduce the weight of IBCA priority. In addition, the priority of the interference
band is considered.

Specifies a period during which the inter-BSC information exchange must be


completed. The information is mainly used by IBCA for C/I ratio estimation.

When the path loss of an MS to a neighboring cell cannot be measured based


on the existing measurement results, it is estimated based on the path loss of
the MS to the serving cell plus the IBCA path loss offset.

Considers the influence of history path loss information during the calculation
of the ICDM algorithm path loss. The smaller the filtering coefficient, the
smaller the influence of history path loss; on the other hand, the larger the
filtering coefficient, the larger the influence of history path loss.

Estimates the receive level of the unmeasured IBCA neighboring cells. When a
consecutive "IBCA Non Measurement Ncell Stat. Num" measurement reports
cover less than six neighboring cells (or the number of the reported
neighboring cells is smaller than that of the actually configured neighboring
cells), this parameter is used to estimate the receive level of the unmeasured
IBCA neighboring cells. The estimated value is "IBCA Pathloss Est of Non. MR
Ncell". Otherwise, the signal strength of the unmeasured IBCA neighboring cells
is the signal strength of the measured neighboring cells (including non-IBCA
neighboring cells) subtracted by "IBCA RxLev Offset".

Use this parameter when the path loss of an MS to serving cells cannot be
measured based on the existing measurement results
MSs that support SAIC can tolerate a lower carrier-to-interference ratio. This
variable indicates the downward adjustment step of the soft blocking threshold
of SAIC MSs.
Whether to deny the access of a call when none of the MAIO evaluation results
meets the C/I ratio requirement of the call during channel assignment
Whether the handover of the calls on the single channels is allowed (single
channels are the two half-rate sub-channels on a timeslot, in which only one is
in the occupied state) when single channels are to be adjusted to a full-rate
channel. When this parameter is set to ON, the handover of the calls on the
single channels is allowed; if this parameter is set to OFF, the handover of the
calls on the single channels is not allowed. This parameter is valid only when
the IBCA algorithm is enabled and full rate is preferred for the newly
established call.
Whether a MAIO meets the access requirement. When the C/I ratio of a MAIO is
higher than this threshold, the MAIO can be assigned to the call being
processed.
Whether to enable the IBCA algorithm for the overlay and underlay of an IUO
cell
Whether a single IBCA MS can dynamically measure the neighboring cells.
When this parameter is set to YES, the neighboring cells where "IBCA Dynamic
Measure Neighbor Cell Flag" is set to YES are dynamically measured. Dynamic
measurement on neighboring cells is mutually exclusive to directed retry. When
this parameter is set to YES, it is recommended that "Direct Retry" be set to
NO.

The lowest C/I ratio that can be tolerated by IBCA WAMR FR. The C/I ratio of an
idle channel must be larger than this parameter. Otherwise, it cannot be
assigned. In addition, the system does not allow a newly-established call
causing the C/I ratio of existing calls to be lower than this parameter.
This parameter is used to enable the Intelligent Combiner Bypass (ICB) function
on the BCCH TRX of a cell.
This parameter specifies whether to allow the cell to enable the ICB function.
When this parameter is set to YES, the TCHs on the non-BCCH TRX are
preferentially assigned. In this way, the largest possible number of idle TCHs is
reserved on the BCCH TRX, and thus the BCCH TRX enters the ICB mode.
Whether to enable the intelligent control of the diesel engine. If this parameter
is set to ENABLE, the PMU will control the diesel engine automatically according
to the settings of the parameters to save the energy. This parameter is set to
ENABLE by default.

ICMP packet length. It is the total length of the ICMP packet containing the IP
header.

DSCP corresponding to the interaction service with the THP level of PRIORITY1

DSCP corresponding to the interaction service with the THP level of PRIORITY2

DSCP corresponding to the interaction service with the THP level of PRIORITY3

Number of the scheduled task

Number of the scheduled task

Index
This parameter indicates the idle code of the A interface. It is used for the
interconnection of the A interfaces.

IDLE code

When the number of idle SDCCH channels in a cell is smaller than this
parameter, the system searches for available TCHs and transforms them into
SDCCH channels.

Type of an index

Index type

Subscribers can specify the cell according to the index or the name.

Type of an index

BTS index type

Index type

Index type of the BTS. BYNAME: query by BTS name; BYID: query by BTS index.

Index type. BYNAME: query by name; BYID: query by index.

Index of the semipermanent link

Support the index based on the TLLI and IMSI mode

Index type, supporting the index based on the cell and BSC mode.
Whether the handshake mechanism is enabled at the Cb interface. Currently,
the BSC6900 and the CBC communications through the TCP/IP protocol. Thus,
the BSC6900 may not detect communication link disconnection in some cases.
The handshake mechanism is used for checking whether a communication link
is normal.
Number of the outgoing interface of a link

Whether to set the middle frequency offset to positive offset or minus offset

Indication offset in the middle frequency offset configuration


Whether to report the progress. "NO" indicates that the progress is not
reported. "YES" indicates that the progress is reported.
Number of invalid measurement reports allowed when the BSC6900 filters the
measurement reports. When the number of received measurement reports is
no larger than this parameter, the BSC does not perform filtering or make quick
handover judgment.

Value of an IMEI

Timer for the BSC6900 waiting for a CC message after sending a CR message. If
the timer expires, the seized SDCCH is released.
The channel activation and immediate assignment messages are sent at the
same time to accelerate the signaling processing, thus increasing the response
speed of the network.
This parameter specifies whether to support the takeover of the packet
immediate assignment by the BTS. It is relative to the uplink immediate
assignment. To improve the access rate of the MS, the BSS allocates the uplink
TBF resources to the BTS in advance. The BTS sends the immediate assignment
message to the MS through the resources allocated by the BSC. When receiving
the immediate assignment message, the MS can send the data block. The BTS
needs to send the assistant channel request to the BSC. When receiving the
request, the BSC sends the immediate assignment request to the BTS to
complete the TDF setup flow.

Whether to allow immediate TCH assignment. If this parameter is set to YES,


the BSC can assign a TCH immediately when there is no available SDCCH for a
channel request. If this parameter is set to NO, the BSC can assign only an
SDCCH when processing a channel access request.

Maximum time delay in resending an immediate assignment message. Within


the period specified by this parameter, an immediate assignment message can
be dispatched and retransmitted. Otherwise, the message is not dispatched or
retransmitted.

Maximum number of retransmissions of an immediate assignment message.


When the value of this parameter is reached, the immediate assignment
message is not retransmitted even if the value of "Max Delay of Imm_Ass
Retransmit" is not exceeded.

Whether the BSC6900 sends immediate assignment retransmission parameters


to the BTS
Whether to assign channels according to the access_delay value in channel
request messages during immediate channel assignment
When the access_delay value in the channel request message is smaller than
this parameter, the overlay channels are assigned preferentially; otherwise, the
underlay channels are assigned preferentially.
Whether to adjust the offset time immediately after the BTS is reset
Timer carried by the Wait Indication information element when the BSC6900
sends an immediate assignment reject message to an MS.
After the MS receives the immediate assignment reject message, the MS
reattempts to access the network after the timer expires.

International mobile subscriber identity of the MS. IMSI containing the number
0 to 9.

Value of an IMSI

Timer for the BSC6900 waiting for a handover complete message after sending
a handover request acknowledgment message in 2G/3G handover or inter-BSC
handover. If the timer expires, a Clear REQ message is reported.

Threshold for fine tuning the BTS clock. If the offset of the BTS clock is smaller
than the threshold, no fine tuning is performed.
Fine tuning period in the BSC
Included angle formed by the major lobe azimuths of the antennas in two cells
under one BTS. A major lobe azimuth is measured from the due north to the
direction of the cell antenna in a clockwise rotation.
Number of the in-port cabinet on a BTS
Whether to separate E1 from other optical fibers for the use of other devices. If
this parameter is set to YES, other BTSs can connect to the BSC6900 through
the independent E1 port 3 of the BTS3006C/BTS3002E.

The triggering of intra-cell F-H handovers must meet the P/N criteria, that is,
when the condition for intra-cell F-H handovers is met for P seconds during N
seconds, an intra-cell F-H handover is triggered. This parameter corresponds to
the P in the P/N criteria.

The triggering of intra-cell F-H handovers must meet the P/N criteria, that is,
when the condition for intra-cell F-H handovers is met for P seconds during N
seconds, an intra-cell F-H handover is triggered. This parameter corresponds to
the N in the P/N criteria.

Information exchange content to be supported

Infrared alarm switch

For an AMR call, if the currently occupied channel is a full rate channel and the
Radio Quality Indication (RQI) is always higher than the threshold set by this
parameter, an intra-cell F-H handover is triggered.

For an AMR call, if the currently occupied channel is a half rate channel and the
Radio Quality Indication (RQI) is always lower than the threshold set by this
parameter, an intra-cell H-F handover is triggered.
Power overload threshold for triggering incoming handover to the TRX under
the prerequisite that the power amplifier of the TRX provides the maximum
output power.
Initial coding mode used for full rate AMR calls. The four values 0, 1, 2, and 3 of
this parameter respectively represent the lowest, low, high, and highest coding
rates in the ACS.

Initial coding mode used for half rate AMR calls. The four values 0, 1, 2, and 3
of this parameter respectively represent the lowest, low, high, and highest
coding rates in the ACS.

Initial coding mode used for broadband AMR calls. The three values 0, 1 and 2
of this parameter respectively represent the lowest, low and highest coding
rates in the ACS.

Specifies the timeslot mask in BSC6900

Whether to assign channel requests in the overlay subcell to the underlay


subcell according to "UL Subcell Lower Load Threshold". If the load of the
underlay subcell is lower than "UL Subcell Lower Load Threshold", incoming
calls in the overlay subcell will be preferentially assigned to the underlay
subcell.
Whether to allow underlay-to-overlay edge handovers

Index of the cell in the BSC

Name of the cell in the BSC

Whether to allow underlay-to-overlay load handovers


Overlay-to-underlay load handovers are performed by levels. This parameter
indicates the duration of each level.

Level step during overlay-to-underlay hierarchical load handovers

In an enhanced dual-band network, if the load of the overlay subcell is higher


than this parameter, the system cannot initiate an underlay-to-overlay
handover.
Number of a BTS port
Incoming BSC6900 port number
In-port number of a DXX

Mode of inputting the latitude and longitude of a cell location

Whether to allow inter-BSC SDCCH handovers

Number of the in-port slot on a BTS


Incoming BSC6900 slot number
Number of the in-port subrack on a BTS
Incoming BSC6900 subrack number
Time interval for sending a simple cell broadcast message

Hysteresis value during the handovers between cells on different layers or of


different priorities. This value is used to suppress inter-layer ping-pong
handovers.

Type of an interference band statistics algorithm used when the frequency


scanning function is enabled. The interference band statistics algorithm I uses
pair average, and the interference band statistics algorithm II uses linear
average.

Reduces ping-pong handovers between cells on a same layer. This parameter is


invalid when cells are on different layers.

Specifies an interval between two consecutive interference handovers

The triggering of interference handovers must meet the P/N criteria, that is,
when P out of N measurement reports meet the condition for interference
handovers, a concentric circle handover is triggered. This parameter
corresponds to the P in the P/N criteria.

The triggering of interference handovers must meet the P/N criteria, that is,
when P out of N measurement reports meet the condition for interference
handovers, a concentric circle handover is triggered. This parameter
corresponds to the N in the P/N criteria.

Whether to allow the interference handover algorithm. Interference handovers


are triggered when the receive level is higher than the receive threshold while
the transmit quality is lower than the interference handover quality threshold,
that is, when the MSs are subject to all kinds of radio interferences.

Whether to consider interference priorities during channel assignment

Threshold used for interference measurement.


The BSS measures the uplink quality of the radio channels occupied by MSs,
and calculates and reports the interference on each of the idle channels. This
helps the BSC6900 to assign channels. According to the strength of interference
signals, the interference signals are classified into five interference levels. The
values of these levels are called interference band thresholds. The BTS
determines the current interference level based on these thresholds, and then
reports a radio resource indication message to the BSC6900. The BSC6900
compares the busy and idle channels reported in the measurement report and
in the radio resource indication message to determine whether to perform a
handover. The interference band statistics result provides reference for
threshold setting and interference analysis. For details, see GSM Rec. 08.08 and
GSM Rec. 08.58.

Threshold used for interference measurement.


The BSS measures the uplink quality of the radio channels occupied by MSs,
and calculates and reports the interference on each of the idle channels. This
helps the BSC6900 to assign channels. According to the strength of interference
signals, the interference signals are classified into five interference levels. The
values of these levels are called interference band thresholds. The BTS
determines the current interference level based on these thresholds, and then
reports a radio resource indication message to the BSC6900. The BSC6900
compares the busy and idle channels reported in the measurement report and
in the radio resource indication message to determine whether to perform a
handover. The interference band statistics result provides reference for
threshold setting and interference analysis. For details, see GSM Rec. 08.08 and
GSM Rec. 08.58.

Threshold used for interference measurement.


The BSS measures the uplink quality of the radio channels occupied by MSs,
and calculates and reports the interference on each of the idle channels. This
helps the BSC6900 to assign channels. According to the strength of interference
signals, the interference signals are classified into five interference levels. The
values of these levels are called interference band thresholds. The BTS
determines the current interference level based on these thresholds, and then
reports a radio resource indication message to the BSC6900. The BSC6900
compares the busy and idle channels reported in the measurement report and
in the radio resource indication message to determine whether to perform a
handover. The interference band statistics result provides reference for
threshold setting and interference analysis. For details, see GSM Rec. 08.08 and
GSM Rec. 08.58.

Threshold used for interference measurement.


The BSS measures the uplink quality of the radio channels occupied by MSs,
and calculates and reports the interference on each of the idle channels. This
helps the BSC6900 to assign channels. According to the strength of interference
signals, the interference signals are classified into five interference levels. The
values of these levels are called interference band thresholds. The BTS
determines the current interference level based on these thresholds, and then
reports a radio resource indication message to the BSC6900. The BSC6900
compares the busy and idle channels reported in the measurement report and
in the radio resource indication message to determine whether to perform a
handover. The interference band statistics result provides reference for
threshold setting and interference analysis. For details, see GSM Rec. 08.08 and
GSM Rec. 08.58.

Threshold used for interference measurement.


The BSS measures the uplink quality of the radio channels occupied by MSs,
and calculates and reports the interference on each of the idle channels. This
helps the BSC6900 to assign channels. According to the strength of interference
signals, the interference signals are classified into five interference levels. The
values of these levels are called interference band thresholds. The BTS
determines the current interference level based on these thresholds, and then
reports a radio resource indication message to the BSC6900. The BSC6900
compares the busy and idle channels reported in the measurement report and
in the radio resource indication message to determine whether to perform a
handover. The interference band statistics result provides reference for
threshold setting and interference analysis. For details, see GSM Rec. 08.08 and
GSM Rec. 08.58.

Threshold used for interference measurement.


The BSS measures the uplink quality of the radio channels occupied by MSs,
and calculates and reports the interference on each of the idle channels. This
helps the BSC6900 to assign channels. According to the strength of interference
signals, the interference signals are classified into five interference levels. The
values of these levels are called interference band thresholds. The BTS
determines the current interference level based on these thresholds, and then
reports a radio resource indication message to the BSC6900. The BSC6900
compares the busy and idle channels reported in the measurement report and
in the radio resource indication message to determine whether to perform a
handover. The interference band statistics result provides reference for
threshold setting and interference analysis. For details, see GSM Rec. 08.08 and
GSM Rec. 08.58.
Value of the timer for synchronization between BSCs. If a BSC fails to
synchronize with the control BSC before the timer expires, the BSC starts to
synchronize the BTSs under its control.

Period during which interference levels are averaged. The interference levels on
idle channels are averaged before the BTS sends a radio resource indication
message to the BSC6900. The averaging result is used for classifying the
interference levels on idle channels into five interference bands. For details, see
GSM Rec. 08.08, 08.58, and 12.21.

This parameter specifies whether the reselection from 2G cells to 3G cells is


allowed.
Threshold for setting the flag of accepting inter-RAT CS service handover of a
2G cell
This parameter specifies whether the handover from 3G cells to 2G cells is
allowed.
Whether to reserve resources for the incoming BSC handover on the Iur-g
interface
Width of load band [EcNo] during the inter-RAT hierarchical load-based
handover

Initial EcNo value of the inter-RAT load-based handover band

Step of changing the EcNo value during the inter-RAT hierarchical load-based
handover

Width of load band [RSCP] during the inter-RAT hierarchical load-based


handover

Initial RSCP value of the inter-RAT load-based handover band

Step of changing the RSCP value during the inter-RAT hierarchical load-based
handover
This parameter specifies whether the handover from 2G cells to 3G cells is
allowed.

When this parameter is set to Service-based, the inter-RAT handover is


triggered on the basis of the service distribution. In this case, the target cell is
selected according to the traffic load.
When this parameter is set to Load-based, the inter-RAT handover is
triggered on the basis of the load balance. In this case, the target cell is
selected according to the traffic load on the target cell and the load difference
between 2G and 3G cells.
When this parameter is set to Dynamic Service/Load based, the target cell is
dynamically selected by using the service-based algorithm or the load-based
algorithm according to the traffic load on the cell.
When this parameter is set to CN
Service-based, the inter-RAT handover decision is made on the basis of the
service attribute of the core network.
When
this parameter is set to OFF, no inter-RAT service handover or inter-RAT load
handover in the access state is performed.

Interval for sending packets to test Ethernet OAM loop

Time span before the command is executed. The logs generated within the time
span are to be exported.
Frequency index of the interference measurement in type 3 of an extension
measurement report

Lower threshold of the overlay level during underlay-to-overlay handovers.


When the receive level of an MS is higher than this threshold, the MS can be
switched to the overlay subcell.
The timer is used to set the time when the BSC6900 waits for an Internal
Handover Command message after a Internal Handover Required message is
reported in an internal BSC handover when A interface is IP. If the timer expires,
the internal BSC handover fails.
Timer started after the BSC6900 delivers a handover command in an intra-BSC
inter-cell handover. If the BSC6900 receives a handover complete message
before this timer expires, the timer stops. If this timer expires, the BSC6900
considers the handover as failed.

Whether to allow AMR handovers. This parameter has no impact on dynamic


non-AMR F-H handovers.

This parameter specifies whether the intra-cell handover is enabled. Note: A


forced intra-cell handover is not subject to this parameter.

Timer started after the BSC6900 delivers a handover command in an intra-BSC


intra-cell handover. If the BSC6900 receives a handover complete message
before this timer expires, the timer stops. If this timer expires, the BSC6900
considers the handover as failed.

Whether it is an RNC under the same MBIC in GU mode

Minimum Ec/No value of a 3G cell during the load-based GSM-to-UMTS


handover

When the load of a cell is greater than or equal to Load HO Threshold, all the
calls in the serving cell send handover requests simultaneously. Thus, the load
on the CPU increases rapidly. In some cases, the cell is congested and call drops
might occur. Therefore, the BSC adopts the hierarchical load handover
algorithm to control the number of calls to be handed over at each level. This
parameter specifies the duration for performing the load-based handover at
each level.

Minimum RSCP value of a 3G cell during the load-based GSM-to-UMTS handover

Incoming BSC6900 start timeslot number

Number of a DXX In-timeslot


Interval for executing the scheduled subtask. If the time mode is set to
"DAILY_C", "WEEKLY_C", or "MONTHLY_C", you should set this parameter.
Automatic switchover interval. This parameter needs to be set only when "OMU
automatic switchover switch" is set to "ON". The minimum automatic
switchover interval is 30 days and the maximum automatic switchover interval
is 1024 days.
Whether a measurement report can contain the information about a cell with an
invalid BSIC. The cell with an invalid BSIC is an unconfigured neighboring cell.
IP address of a BTS port. It cannot be the same as any IP address configured in
the BSC6900.
IP address
IP address of the local NSVL

IP address of the remote NSVL

IP address of the server

IP address of the FTP server. When the FTPServer.exe file is downloaded


through the FTP Tool button on the LMT, the address of the FTP server is the
same as that of the LMT client.

IP address of the board

IP address of the router

The local IP address must be the configured IP address (including the IP address
and port address of the interface board).

Local IP address of the Ethernet port


Source IP address of the packet for preventing the ICMP attack

IP address of the next hop


Local IP address of the aggregation group
It must be the valid address of the A, B, or C type and cannot be the broadcast
address or network address.
First IP address of the SGSN
It must be the valid address of the A, B, or C type and cannot be the broadcast
address or network address.
Second IP address of the SGSN

Third IP address of the SGSN

Fourth IP address of the SGSN

When the number of error frames on the IP layer reaches the value of this
parameter, the frame error alarm is generated.

When the number of error frames on the IP layer decreases to the value of this
parameter, the frame error alarm is cleared.

Whether to compress the packet headers

Whether to compress the IP header of a MP group


IP address index of the Ethernet port
IP address index of the aggregation group
IP packet multiplex index

Type of the physical IP transmission medium

Type of IP physical transmission cable medium, E1 or FE/GE.

Whether to enable the heater.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether the BSC is a reference BSC

Whether the cell is a chain neighboring cell. The parameter is used in the quick
handover algorithm. Quick handover aims to increase the handover success
rate of an MS moving at a high speed and to ensure the call continuity and low
call drop rate. Quick handover applies to the scenario where an MS moves fast
along an urban backbone road, a selected route, or a high-speed railroad. The
target cell must be a chain neighboring cell.

Whether to support clock server redundancy configuration

Whether to support clock server redundancy configuration

Whether to enable the BTS to support ring networking. IP BTS does not support
this parameter.

If this parameter is set to "YES", the check threshold for a specific board is
used. In this case, the following paramters are involved: Forward Bandwidth,
Receive Bandwidth, Power Class, TRX Number. If this parameter is set to "NO",
the check threshold for a certain class of boards is used.
A service support attribute of a cell, that is, whether an external GSM cell
supports EDGE
Whether to indicate the first class transport resource group
A service support attribute of a cell, that is, whether an external GSM cell
supports GPRS
Whether to enable the TRX to carry the main BCCH in the cell

Whether a BSC in the TC pool is the primary BSC


Whether this location group is the main location group. If the value is Yes, this
location group is the main location group. If the value is No, this location group
is the slave location group.
A service support attribute of a cell, that is, whether an external GSM cell
supports NC2
Configuration mode of the IP subnetwork. Static configuration: fixed local NSVL
and remote NSVL parameters through manual configuration; Dynamic
configuration: the NSVL parameter obtained through negotiation between the
BSC and the SGSN after the local NSVL and SGSN service point are configured
manually.
Whether it is QOSPATH

Whether the Um interface software synchronization between BSCs is supported

Whether multiple DEMUs are configured

ISSUPERBTS

Whether to enable the BTS to support local switching


If the BTS supports local switching, when the calling and called MSs are both
within the BTS or BTS group, the voice signals are looped back to the MSs
within the BTS or BTS group instead of being sent over the Abis interface to the
BSC and MSC. In this way, the Abis resources between the convergence BTS
and the BSC are released and saved.

Whether to support the TC pool function. The TC Pool feature is implemented by


connecting the maim processing subracks (MPSs) and extended processing
subracks (EPSs) in multiple BSC6900s to the transcoder subracks (TCSs) of one
BSC6900. In this manner, all the involved BSC6900s share the TC resources,
and the shared TC resources form a TC Pool. The TC Pool feature is applicable to
only the BSC6900s whose "Service mode " is set to SEPARATE.
Whether it is a TC board.If the board is for the TC subrack, set the parameter to
YES.
If the board is not for the TC subrack, set the parameter to NO.
Whether the subrack is a remote main TC subrack

Whether to control the temperature difference between the air inlet and air
outlet and that between the air outlet and ambient by the temperature control
system.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to configure the transmission cabinet. The BTS uses this parameter to
calculate the number of TRXs to be shut down.

Number of a row to be changed in a BA list

Reserved parameter for cells. There are 30 parameters of this type, which can
be used as new parameters in later versions.

Used for parameter control

Value of a reserved parameter for cells

Type of the adjacent node

Type of the interface. This is determined by the type of the protocol currently
used by the BTS. Point-to-Point Protocol (PPP) is a data link protocol. Multilink
PPP (MP) is a bandwidth-on-demand protocol that binds multiple links together
according to PPP (also called link aggregation).
Concentric cell attributes of TRX. If the cell where a TRX is located is configured
as a concentric cell, set this parameter to OVERLAID or UNDERLAID as required.
If the cell where a TRX is located is not configured as a concentric cell, the
default value of this parameter is NONE.

Conversion policy of the dynamic channel of the concentric cell

The triggering of concentric circle handovers must meet the P/N criteria, that is,
when P out of N measurement reports meet the condition for concentric circle
handovers, a concentric circle handover is triggered. This parameter
corresponds to the P in the P/N criteria.
The triggering of concentric circle handovers must meet the P/N criteria, that is,
when P out of N measurement reports meet the condition for concentric circle
handovers, a concentric circle handover is triggered. This parameter
corresponds to the N in the P/N criteria.

Whether a cell is a normal cell, concentric cell, or enhanced dual band network
cell.
In a concentric cell, the coverage areas of different TRXs form concentric circles
of different radiuses.
Owing to different coverage areas of the overlaid and underlaid parts, the two
parts can be logically regarded as two cells. With many channels, the overlaid
part is the major traffic bearer layer, recruiting most MSs in its coverage area.
The underlaid part is used for coverage, providing services for the areas that
the overlaid part cannot cover. The underlaid part covers the overlaid part, and
thus the underlaid part can also share some traffic.
An enhanced dual band network is amelioration to the existing dual band
network. In such a network, two cells physically with a collocation site but
different coverage areas form a cell group logically, namely, an inner cell and
an extra cell. Channel resource sharing and cell load balancing is realized in the
two cells through the algorithm of enhanced dual band network.

Switch for the J0 tracing mark mismatching alarm

Byte display format of J0


Expected receiving value of J0. J0 byte, also called the trace byte of the
regenerator section on the optical port (RTIM), is one of the optical port
interconnection parameters. The BSC receives the peer J0 byte continuously.
Sending value of J0. J0 byte, also called the trace byte of the regenerator
section on the optical port (RTIM), is one of the optical port interconnection
parameters that is continuously transmitted to the peer end. This parameter
enables the peer end to check whether it is connected to the local end
continuously.

J0 type

Switch for the J1 tracing mark mismatching alarm

Byte display format of J1


Expected receiving value of J1. J1 byte, also called the trace byte of the highorder path on the optical port, is one of the optical port interconnection
parameters. The local end continuously receives the peer J1 byte.
Sending value of J1. J1 byte, also called the trace byte of the high-order path on
the optical port, is one of the optical port interconnection parameters
transmitted to the peer end continuously. This parameter enables the peer end
to check whether it is connected to the local end continuously.

J1 type

Switch for the J2 tracing mark mismatching alarm

Byte display format of J2

Byte length of J2

Expected receiving value of J2

Sending value of J2

A zero or a space used to fill in the J byte of the optical port based on the J byte
of the peer equipment. If the J bytes are inconsistent, an alarm related to J byte
mismatch will be reported and the negotiation of the optical port may fail, thus
leading to deterioration of the services.
Whether to enable the LAPD Jitter Buffer algorithm. This algorithm adds a
buffering adaptation layer under the LAPD layer at the receiving end. The
function at this layer is to delay the I frame (first received, last sent) currently
received. If an I frame is received within the delayed duration, the frame is sent
to the LAPD layer. In this way, the frame disorder is avoided.
Default receive delay of the PS Jitter Buffer on the BTS. A greater value of this
parameter indicates a longer end-to-end delay for the PS service.

Whether the LAPD Jitter Buffer is enabled on the BSC side

Determines whether the last three bits of K2 indicates the single end and the
dual end
K offset used in K sequencing. To reduce ping-pong handovers, the system
performs K sorting based on the downlink receive level of the candidate cells.
But before doing that, the system subtracts "K Bias" from the actual downlink
receive level of the candidate cells.
Duration of the PPP/MP link keep-alive timer

Location area code (LAC). MSs can freely move in the local location area with no
need of location update. Reasonable local allocation can effectively lighten the
signaling load and improve the call completion rate.
Can be input in hexadecimal format. The hexadecimal format is H'****, for
example, H'1214.

Location area code (LAC). The MS can move within the local location area
without location update. The reasonable classification of the location area is
very important for reducing the signaling load and improving the put-through
rate.
Aggregation mode. When this parameter is set to static aggregation, the LACP
protocol is activated; otherwise, the LACP protocol is deactivated.
Decimal value when the latitude where a cell is located is indicated in the
format of degree
Decimal value when the longitude where a cell is located is indicated in the
format of degree
Integer value when the latitude where a cell is located is indicated in the format
of degree
Value of the minute part when the latitude is indicated in the format of
degree_minute_second
Decimal value of the second part when the latitude is indicated in the format of
degree_minute_second
Integer value of the second part when the latitude is indicated in the format of
degree_minute_second
Longitude of the GPS receiver antenna
Longitude of the GPS receiver antenna

Delay statistics period. This parameter indicates the period to collect the
statistics information about the link transmission delay. Note that the unit of
this parameter is 100 milliseconds. The actual delay statistics period is the
value of this parameter multiplied by 100 milliseconds.
Number of delay adjustment suspension periods. This parameter specifies the
delay statistics periods in which the bandwidth is not adjusted when the
bandwidth adjustment function of the logical port is triggered due to the
change of the link transmission delay. This parameter can be used to control
the rate of the bandwidth adjustment at the logical port.
Bandwidth reduction delay threshold. This parameter is used to trigger the
function of bandwidth reduction at the logical port when the link delay exceeds
the value of this parameter.
Average delay reduction filtering index

Average delay increase filtering index


Layer where a cell is located. The network designed by Huawei has four layers:
Umbrella (layer 4), Macro (layer 3), Micro (layer 2), and Pico(layer 1). Each layer
can be set with 16 priorities.
A network basically consists of four layers, namely, Umbrella, Macro, Micro, and
Pico. Cell priorities influence the sorting of neighboring cells during handovers
as well as handover algorithms including PBGT and inter-layer handovers. For
example, PBGT handovers can only occur among cells on a same layer and of a
same priority level. If you assign different layers and priorities to a 1800-M cell
and a 900-M cell, PBGT handovers from the 1800-M cell to the 900-M cell will
not occur. This causes slow handovers even when the receive quality is good.

When the load of the serving cell reaches the threshold, the inter-layer
handover algorithm takes effect. Through configuration of the parameter, the
handover to a lower-layer cell for load-sharing is performed only when the load
of the serving cell reaches a certain level.
Timer of increasing the Lb flow control level when the BSC receives an SMLC
congestion indication. If the BSC receives another SMLC congestion indication
before the timer expires, the flow control level remains unchanged.
Timer of decreasing the Lb flow control level. If no SMLC congestion indication
is received within the valid period of the timer, the BSC decreases the flow
control level by one until the flow control level is decreased to 0.

Fourth action taken for load control

First action taken for load control

Second action taken for load control

The local entity number uniquely identifies a local entity.


Class of the maintenance domain
Alarm mask switch

Log level to be collected.

Level of the log

Whether to support the reporting of the main diversity level

Whether to allow inter-layer and inter-level handovers. The inter-layer and interlevel handover algorithm is achieved through the setting of different layers and
priorities for cells, which switches traffic to cells of a higher precedence
(decided by "Layer of the cell" and "Cell priority" together).
Hysteresis value during the handovers between cells on different layers or of
different priorities. This value is used to suppress inter-layer ping-pong
handovers.
Inter-layer handover threshold of the serving cell = "Inter-layer HO threshold" "Inter-layer HO Hysteresis";
Inter-layer handover threshold of a neighboring cell = "Inter-layer HO threshold"
+ "Adjacent Cell Inter-layer HO Hysteresis" - 64.

The triggering of inter-layer handovers must meet the P/N criteria, that is, when
the condition for inter-layer handovers is met for a consecutive P seconds
during N seconds, an inter-layer handover is triggered. This parameter
corresponds to the P in the P/N criteria.

The triggering of inter-layer handovers must meet the P/N criteria, that is, when
the condition for inter-layer handovers is met for a consecutive P seconds
during N seconds, an inter-layer handover is triggered. This parameter
corresponds to the N in the P/N criteria.

Logical function type

Logical function type of the board


OAM:Operation And Maintenance Process
TDM_Switching:TDM switching process
GCP:All the GCP subsystems are configured as CPUS to act as the control plane
processing subsystems for GSM BSC
RGCP:Subsystem 0 of RGCP is configured as the MPU subsystem to act as the
resource management subsystem. The other seven subsystems are configured
as CPUS to act as the control plane processing subsystems for GSM BSC
MCP: Mathematics Computing Process, which includes Interference Based
Channel Allocation (IBCA)
GTC:GSM BSC TC Process
GPCU:GSM BSC PCU Process
IP:GOUc/IP IP over GE Optical interface,GOUa/IP IP over GE Optical
interface,PEUa/IP IP over E1/T1/J1 interface,FG2c/IP IP over FE/GE
interface,FG2a/IP IP over FE/GE interface(not support GbIP),POUc/IP IP over
channelized Optical STM-1/OC-3 interface
FR:PEUa/FR Frame Relay over E1/T1/J1 interface
HDLC:PEUa/HDLC Packet over E1/T1/J1 interface
TDM:POUc/TDM channelized Optical STM-1/OC-3 interface
GbIP:FG2a/GbIP GSM BSC Gb IP interface
Abis_TDM:EIUa/Abis_TDM E1/T1 circuit Interface for Abis,OIUa/Abis_TDM
channelized Optical STM-1 Interface for Abis
Ater_TDM:EIUa/Ater_TDM E1/T1 circuit Interface for Ater,OIUa/Ater_TDM
channelized Optical STM-1 Interface for Ater Pb_TDM:EIUa/Pb_TDM E1/T1
circuit Interface for Pb,OIUa/Pb_TDM channelized Optical STM-1 Interface for Pb
A_TDM:EIUa/A_TDM E1/T1 circuit Interface for A OIUa/A_TDM channelized
Optical STM-1 Interface for A
SAU:Service Aware Uint

Logical function type of the board

Application type of the POUc_TDM board


The Logical Index of PB signaling link

Lower humidity threshold for the environment alarm box to report an alarm
indicating that the ambient humidity is too low. If the ambient humidity of the
BTS is lower than this threshold, the environment alarm box reports the alarm.
In multi-mode scenario, the value of this parameter in this mode must be the
same as the value of the corresponding parameter in another mode.

The occur threshold of 20258 alarm,you can set it from 90% to 99%

The recover threshold of 20258 alarm,you can set it from 90% to 99%
Key field used to identify one LAPD link
Type of the parameters to be displayed when a cell template is queried. The
value "DIFFERENCE" indicates that the parameters in the cell template that are
different from those in the default template are displayed. The value "ALL"
indicates that all the parameters in the cell template are displayed.
Rate type of the designated link
Lower limit of an alarm. It is valid for the analog port.

Lower limit for triggering an alarm

The loopback channel number when the port loopback mode is set to single
channel local loopback

Upper threshold of the low noise amplifier. When the working voltage of the low
noise amplifier attenuator in the RXU board is smaller than this value, an alarm
is reported by the BTS.
Lower threshold of the low noise amplifier. When the working voltage of the low
noise amplifier attenuator in the RXU board is greater than this value, an alarm
is reported by the BTS.
Optical interface tributary numbering method. This parameter indicates the
sequence of tributaries in an SDH frame.
Rate of the semipermanent link
Initial bearing tag of the M3UA link. This parameter can be set to either active
mode or standby mode. For details about the relevant bearer tag, see the the
parameter "Traffic mode" of the "ADD M3LKS".
Link load sharing. In the value, the number of 1s (represented by n) determines
the maximum number (2^n) of links for the load sharing. For example, B0000
indicates that up to one link is used for the load sharing, B0001 and B1000
indicate that up to two links are used for the load sharing. The additional links
are not used for the load sharing. The AND operation between this value and "
signaling route mask " in the N7DPC is equal to 0.
Signaling link mask corresponding to the M3UA link set. It is used for the M3UA
link load sharing. It is valid only when the working mode of the signaling link
set is set to load sharing. In the value, the number of 1s (represented by n)
determines the maximum number (2^n) of links for the load sharing. For
example, B0000 indicates that up to one link is used for the load sharing,
B0001 and B1000 indicate that up to two links are used for the load sharing.
The additional links are not used for the load sharing. The AND operation
between this value and " signaling route mask " in the "ADD N7DPC" is equal to
0.

If the load of a cell is lower than the value of this parameter, the cell can admit
the users handed over from other cells with higher load. Otherwise, the cell
rejects such users.

Type of load balancing algorithm of the MSC Pool. Generally, the BSC6900
chooses an MSC according to the obtained network resource indication (NRI). In
some cases, however, the BSC6900 cannot do so. Instead, the BSC6900
chooses a target MSC according to a load balancing algorithm.
Intervals that the BSC broadcasts a cell's traffic load to its neighbor cells. The
uplink load and downlink load indicate the traffic situation of a cell. The uplink
load = number of uplink TBFs carried on all PDCHs in a cell / total number of
PDCHs in a cell x ("PDCH Uplink Multiplex Threshold"/10) x 100%. The downlink
load = number of downlink TBFs carried on all PDCHs in a cell / total number of
PDCHs in a cell x ("PDCH Downlink Multiplex Threshold"/10) x 100%.

Load current shunt coefficient


This parameter specifies whether to use the load handover or the enhanced
load handover.

This parameter specifies whether a traffic load-sharing handover is enabled.


The load handover helps to reduce cell congestion, improve success rate of
channel assignment, and balance the traffic load among cells, thus improving
the network performance. The load handover is used as an emergency measure
instead of a primary measure to adjust abnormal traffic burst in partial areas. If
load handovers occur frequently in a partial area, the cell and TRX configuration
of BTSs and the network layout should be adjusted.
Indicates that if a 2G neighboring cell supports load handovers, the BSC adds
the load information of the local cells in the signaling procedures related to this
neighboring cell.
Indicates that if a 3G neighboring cell supports load handovers, the BSC adds
the load information of the local cells in the signaling procedures related to this
neighboring cell.
If the path loss in the serving cell minus that in a handover candidate cell is not
smaller than the parameter value, the handover to the candidate cell is
allowed. The parameter loosens the requirement of the PBGT handover
threshold when the load of the serving cell reaches a certain level. Some traffic
that could not be handed over to a neighboring cell through the PBGT handover
can be handed over now. The value "0" indicates that the enhanced load
handover to the neighboring cell is not allowed.

After a load handover succeeds, the BSC punishes the former serving cell
during "Penalty Time on Load HO" by subtracting "Penalty Value on Load HO"
from the receive level of the former serving cell, thus avoiding ping-pong
handovers.

After a load handover succeeds, the BSC punishes the former serving cell
during "Penalty Time on Load HO" by subtracting "Penalty Value on Load HO"
from the receive level of the former serving cell, thus avoiding ping-pong
handovers.

When the load of a cell reaches or exceeds "Load HO Threshold", all the calls
that are using this cell as the serving cell generate handover requests at the
same time, which will suddenly increase the load of the processor. Under some
circumstances, congestion occurs in the cell, which will result in call drop. To
solve this problem, the BSC uses the hierarchical load handover algorithm to
control the number of users included in each level of handovers.
This parameter indicates the duration of each handover level.

In hierarchical load handovers, starting from "Edge HO DL RX_LEV Threshold", a


"Load HO Step Level" is added to the upper handover threshold after every
"Load HO Step Period". In this way, all the calls in the current serving cell
whose receive level is in the range "Edge HO DL RX_LEV Threshold" to "Edge
HO DL RX_LEV Threshold" + "Load HO Bandwidth" are switched to other cells.
This parameter specifies the ratio of the MSs that simultaneously perform a
load handover. You can enlarge the ratio to accelerate the handover to a
neighboring cell for load sharing. Too large a ratio, however, causes the
neighboring cell to be congested. When a neighboring cell is congested, you
need to reduce the ratio to a reasonable value.
In the handover algorithm of the first generation, load handovers can be
performed only when the receive level of the current serving cell is in the range
"Edge HO DL RX_LEV Threshold" to "Edge HO DL RX_LEV Threshold" + "Load
HO Bandwidth".
In the handover algorithm of the second generation, load handovers can be
performed only when the level difference between the neighboring cell and the
serving cell is between "Inter-cell HO Hysteresis" - "Load HO Bandwidth" and
"Inter-cell HO Hysteresis".
Whether to enable load power-off.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to allow the cell load reselection. If this parameter is set to PERMIT
and "NC2 Load Reselection Switch" is set to Support, the load of the target cell
is involved in the algorithm for NC2 cell reselection.
Threshold for allowing the MS to reselect a cell during load reelection. When the
receive level of the serving cell is lower than this threshold, the load reselection
is triggered.

When the uplink load or downlink load of the target cell is lower than this
threshold, it can accept the MSs from the serving cell due to load reselection.

When the uplink load or downlink load of the cell exceeds this threshold, the
load reselection decision is made.
If this parameter is set to YES, the channel assignment algorithm II randomly
selects the start range for channel traversal; otherwise, the algorithm selects
the channel next to the channel assigned last time as the start point of channel
traversal.
This parameter specifies whether the dynamic PDCHs that have been
converted into the PDCHs are considered during the calculation of the current
cell load.
TRM load threshold switch

Local BSC identity. It identifies a BSC.

Local IP address of BTS PPP Link.

Local IP address of BTS MLPPP Group.

Local IP address of PPP link. The IP address of the PPP link on the BSC side.
Local IP address of the MP group
Identifies a local NSVL
Identifies the local port of the router. The setting of this parameter must be
consistent with the setting at the SGSN side.

Number of the location group under the BTS. It is unique for each BTS.

Number of a location group

The value of this parameter can include one or two conditions.


"&" is used to concatenate the conditions, and the records are obtained when
the two conditions are matched.
Conditions are written in the format of "name : value".
"name" is the key of location information, "value" is the value of location
information.
Both "name" and "value" are case sensitive.
For example: 1. If you need to obtain all the alarms regarding the subrack 0, set
lockeyinfo to "Subrack No : 0".
For example: 2. If you need to obtain all the alarms regarding the slot 8 in
subrack 0, set lockeyinfo to "Subrack No : 0&Slot No : 8".
Identifies the first local IP address that communicates with the peer end. When
it is set to 0, it is invalid. This IP address must be first configured on the
corresponding interface board.
Identifies the second local IP address that communicates with the peer end.
When it is set to 0, it is invalid. This IP address must be first configured on the
corresponding interface board.
Whether to lock all the non-default local accounts

Local SCTP port number

Board start load control

Mode of software loading


CPU usage threshold for log flow control. When the average CPU usage of
sliding windows reaches or exceeds the threshold, log flow control is triggered.
Packet queue usage threshold for log flow control. When the average packet
queue usage of sliding windows reaches or exceeds the threshold, log flow
control is triggered.
Whether the SCTP is bound to a logical port. For details, see "ADD
IPLOGICPORT".

Logical port No. bound by the SCTP. For details, see the parameter "Logic port
No." of the "ADD IPLOGICPORT".

Logical port slot No. bound by the SCTP. For details, see the parameter "Slot
No." of the "ADD IPLOGICPORT".
CPU usage threshold for recovery from log flow control. When the average CPU
usage of sliding windows is lower than the threshold, log flow control is
triggered.
Packet queue usage threshold for recovery from log flow control. When the
average packet queue usage of smooth windows is lower than the threshold,
log flow control is triggered.
Whether to control the log flow

The log type to be collected.

Type of the log. "COMLOG" indicates a common log. "CMPLOG" indicates a


compressed log.
Decimal value when the longitude where a cell is located is indicated in the
format of degree
Value of the degree part when the latitude is indicated in the format of
degree_minute_second
Integer value when the longitude where a cell is located is indicated in the
format of degree
Value of the minute part when the longitude is indicated in the format of
degree_minute_second

Decimal value of the second part when the longitude is indicated in the format
of degree_minute_second
Integer value of the second part when the longitude is indicated in the format
of degree_minute_second
Latitude of the GP receiver antenna
Latitude of the GPS receiver antenna
Loop level
Loop type
1. Local loop:Make loop test on the local board at system side, while the system
platform will send test frames.
2. Remote loop:The remote-loop will be made by the device on the other side of
the local board. In this case, the local board don't need to make loop opertation
except sending test frames.

Loop Detect Switch

Loopback type of LAPD link


When the load of an SDCCH on the TRX that is in loose frequency reuse and is
in the compatible band of the BCCH is lower than this threshold, the SDCCH is
preferably allocated.
Direction of an external voice loop

subrack on the Abis interface side. The loopback point is available only in
BM/TC separated configuration mode.
NSS TC(Near A Interface): indicates the TX/RX point on the DSP in the TC
subrack on the A interface side. The loopback point is available only in BM/TC
separated configuration mode.
NSS TNU(Near Abis Interface): indicates the data switching point on the TNUa
board in the TC subrack on the Abis interface. The loopback point is available
only when the Ater interface uses the TDM transmission in BM/TC separated
configuration mode.
NSS TNU(Near A Interface): indicates the data switching point on the TNUa
board in the TC subrack on the A interface side. The loopback point is available
only in BM/TC separated configuration mode.
NSS Ater Interface Unit: indicates the Ater interface board in the TC subrack. It
is available only in BM/TC separated configuration mode.
BSS Ater Interface Unit: indicates the Ater interface board in the BM subrack. It
is available only in BM/TC separated configuration mode.
BSS TC(Near Abis Interface): indicates the TX/RX point on the DSP in the BM
subrack on the Abis interface side. In BM/TC combined or A over IP
configuration mode, the loopback point is available. In BM/TC separated
configuration mode, the loopback point is available only in Abis over IP/HDLC
and Ater over TDM transmission mode, or in Abis over TDM transmission and
Ater over IP transmission mode.
BSS TC(Near A Interface): indicates the TX/RX point on the DSP in the BM
subrack on the A interface side. In BM/TC combined or A over IP configuration
mode, the loopback point is available. In BM/TC separated configuration mode,
the loopback point is available only in Abis over IP/HDLC and Ater over TDM
transmission mode, or in Abis over TDM and Ater over IP transmission mode.
BSS TNU(Near Abis Interface): indicates the data switching point on the TNUa
board in the BM subrack on the Abis interface side. The loopback point is
available only in Abis over TDM transmission mode regardless of the
configuration mode of BM/TC separated, BM/TC combined, or A over IP..
BSS TNU(Near A Interface): indicates the data switching point on the TNUa
board in the BM subrack on the A interface side. In BM/TC combined
Loopback type

Loopback type

Time of an external voice loop

Number of suspension periods after the bandwidth adjustment is performed


based on the packet drop ratio. This parameter specifies the delay statistics
periods in which the bandwidth is not adjusted when the bandwidth adjustment
function of the logical port is triggered due to the change of the packet drop
ratio. This parameter can be used to control the rate of the bandwidth
adjustment at the logical port.
Whether to permit the preemption of lower-level sublink resources. If the value
of this parameter is YES, a CS domain service can preempt the sublink
resources of the PS domain services on the lower-level BTS of the cascaded
BTSs when the CS domain service fails to preempt the sublink of the
corresponding level.
The CS services are preferred. This parameter indicates that the CS services are
permitted to preempt the dynamic Abis resources on the sublink of the current
level site.
Whether to permit the low noise amplifier (LNA) bypass

Whether to assign overlay channels in an IUO cell based on the receive level
conditions

Whether to power off the TRX in the case of overlow temperature of the BTS
cabinet.
If this parameter is set to "Yes", the BTS powers off the TRX and reports a "Load
Power Off Alarm" to protect the TRX in the case of overlow temperature of the
BTS cabinet. When the cabinet temperature returns to 0 celsius degree, the
BTS powers on the TRX, and the alarm disappears.
Whether to power off the TRX of a BTS when the temperature of the BTS
cabinet is too low.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Loopback mode

Number of the IP logical port that carries the IP path

Logical port number

Logical port number

Number of the IP logical port that carries the IP path

Type of logical port

It is applicable to the radio transmission environment to improve the link


quality. Link adaptation (LA) indicates adjusting the coding mode of the channel
dynamically according to the transmission quality of the link. The link
transmission quality is measured by the 8PSK MEAN BEP and 8PSK CV BEP in
the Packet EGPRS Downlink Ack/Nack message sent by the MS. The network
side determines the coding mode for data transmission according to the radio
measurement report sent by the MS. The cell with the good transmission
quality on the air interface is set to the LA mode. Increment redundancy (IR)
mode requires the network side retransmit the data block with different
punching codes and the MS store the historical error information. The data
block is retransmitted through cooperated error correction function. With the IR
mode, the transmission quality on the air interface of the cell can be improved.
However, the MS must support this IR mode. The cell with the dissatisfied
transmission quality on the air interface is set to the LR mode.

Whether to enable power shutdown upon low voltage of the battery.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Load power-off voltage threshold. If "Load Shutdown Flag" is set to "Enable"
and the load voltage is lower than the value of this parameter, the load is
automatically powered off.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Third action taken for load control

Whether to include the list command

Query results can be displayed vertically or horizontally

Format of the result list

Loading type

Type of the log

Type of the log

Temperature control threshold for low temperature. When the ambient


temperature is less than "Low Temperature Critical Point", the temperature
control system needs to control the temperature difference between the air
inlet and air outlet, and that between the air inlet and ambient temperature.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Lower temperature threshold for the environment alarm box to report an alarm
indicating that the ambient temperature is too low. If the ambient temperature
of the BTS is lower than this threshold, the environment alarm box reports the
alarm.
In multi-mode scenario, the value of this parameter in this mode must be the
same as the value of the corresponding parameter in another mode.

Lower voice quality threshold associated with the automatic adjustment of the
AMR handover uplink threshold;The value of this parameter must be smaller
than or equal to the value of Uplink Long-term FER Target.

Target voice quality value associated with the automatic adjustment of the
uplink threshold of AMR handover

Upper voice quality threshold associated with the automatic adjustment of the
AMR handover uplink threshold

Factor of uplink threshold adjustment. It indicates the linear relation between


the threshold adjustment value and the logarithmic FER.

Number of DSPs, each of which carries 252 LVDS links on the DPUd or DPUb
board. If this parameter is set to 0, every DSP carries 192 LVDS links by default.

The level 1 Voltage Standing Wave Ratio (VSWR) threshold. When the VSWR is
higher than this parameter, the TRX will report a level-1 VSWR alarm. At this
time, the BTS can provide services but its coverage rate decreases.
The level 2 Voltage Standing Wave Ratio (VSWR) threshold. When the VSWR is
higher than this parameter, the TRX will report a level-2 VSWR alarm. At this
time, the BTS disables power amplification and fails to provide services.

Whether "Shutdown Voltage" is valid.


In multi-mode base station scenario, the value of this parameter in different
modes must be the same for the same multi-mode base station.

Number of the M3UA service listening port

MAC address of the VLAN


When the number of error frames on the MAC layer reaches the value of this
parameter, the frame error alarm is generated.
When the number of error frames on the MAC layer decreases to the value of
this parameter, the frame error alarm is cleared.
Coding mode in which an ARFCN is sent to an MS during an assignment or
handover. If the parameter is set to CA_MA, an ARFCN is indicated through the
CA and MA information contained in an assignment or handover command. If
the parameter is set to Frequency_List, an ARFCN is indicated through the
Frequency List information contained in an assignment or handover command.
If this parameter is set to OPTIMIZED_CA_MA, the assignment command carries
only the MA but not the CA when a cell works on only one frequency band, and
the assignment command carries both the MA and CA if the cell works on more
than one frequency band.

Identifies a maintenance group.


Maintenance group: maintenance alliance (MA), which is a component of the
maintenance domain (MD). Maintenance domain is an Ethernet or a component
of an Ethernet in which the connectivity failure management is performed. The
maintenance domain is uniformly managed by one ISP. One MD can be divided
into one or more maintenance group.

When this parameter is set to YES, the BSC6900 is allowed to reduce the
transmit power of the non-BCCH timeslots on the BCCH TRX.
This parameter specifies whether to enable the Enhanced BCCH Power
Consumption Optimization feature. Generally, the BCCH TRX transmits signals
at the maximum transmit power. When this parameter is set to YES, the
BSC6900 is allowed to reduce the transmit power of the non-BCCH idle
timeslots on the BCCH TRX.

This parameter specifies the end time of the period during which the power of
the non-BCCH timeslots on the BCCH TRX is derated.

This parameter specifies the range of power derating over the non-BCCH
timeslots on the BCCH TRX.

This parameter specifies the start time of the period during which the power of
the non-BCCH timeslots on the BCCH TRX is derated.

Bar code 1 of the BTS interface board


Bar code 1 of the interface board of the BTS. This parameter is the electronic
serial number of the active PTU board. An electronic serial number uniquely
identifies an PTU board. This parameter is set before delivery.
Number of main location group. Each cell contains only one main location
group.
Number of the port to which the active OML of the BTS is connected
Main version No. of the TMU board software. It is configured according to the
actual situation.
Mobile allocation index offset 1. Start frequency number, which is the number
of the frequency where frequency hopping starts
Mobile allocation index offset 10. Start frequency number, which is the number
of the frequency where frequency hopping starts
Mobile allocation index offset 11. Start frequency number, which is the number
of the frequency where frequency hopping starts
Mobile allocation index offset 12. Start frequency number, which is the number
of the frequency where frequency hopping starts
Mobile allocation index offset 2. Start frequency number, which is the number
of the frequency where frequency hopping starts

Mobile allocation index offset 3. Start frequency number, which is the number
of the frequency where frequency hopping starts
Mobile allocation index offset 4. Start frequency number, which is the number
of the frequency where frequency hopping starts
Mobile allocation index offset 5. Start frequency number, which is the number
of the frequency where frequency hopping starts
Mobile allocation index offset 6. Start frequency number, which is the number
of the frequency where frequency hopping starts
Mobile allocation index offset 7. Start frequency number, which is the number
of the frequency where frequency hopping starts
Mobile allocation index offset 8. Start frequency number, which is the number
of the frequency where frequency hopping starts
Mobile allocation index offset 9. Start frequency number, which is the number
of the frequency where frequency hopping starts
Critical alarm threshold against excessive TMA feed current of feed tributary 0.
When the actual current is greater than the specified value, a TMA feed current
critical alarm is generated.
Critical alarm threshold against excessive TMA feed current of feed tributary 1.
When the actual current is greater than the specified value, the TMA feed
current critical alarm is generated.
Critical alarm threshold against excessive TMA feed current of feed tributary 2.
When the actual current is greater than the specified value, the TMA feed
current critical alarm is generated.
Critical alarm threshold against excessive TMA feed current of feed tributary 3.
When the actual current is greater than the specified value, the TMA feed
current critical alarm is generated.
Critical alarm threshold against excessive TMA feed current of feed tributary 4.
When the actual current is greater than the specified value, the TMA feed
current critical alarm is generated.
Critical alarm threshold against excessive TMA feed current of feed tributary 5.
When the actual current is greater than the specified value, the TMA feed
current critical alarm is generated.

Name of the maintenance association.

Name of the MA

Subnet mask of BTS PPP link.

Subnet mask of BTS MLPPP Group.

Subnet mask of the MP group in BSC.

IP subnet mask of a BTS port


Subnet mask of the board
Subnet mask corresponding to the local IP address of the PPP link
Mask of the source IP network segment of the packet against the ICMP attack

Subnet mask

Subnet mask of the CBC


IP address of the main clock server. It must be a legal A/B/C type address but
not a broadcast address or network address.
It must be the valid address of the A, B, or C type and cannot be the broadcast
address or network address.

Step of upward power adjustment according to the quality of the received


signals

If the number of the association retransmissions exceeds this value, the


parameter is deleted automatically. The value must be greater than Path max
retrans.
Maximum bandwidth for dynamic adjustment at the logical port

Number of consecutive intra-cell handovers allowed in a cell. When the interval


between two intra-cell handovers is lower than a certain time threshold, these
two intra-cell handovers are considered consecutive. When a certain number of
intra-cell handovers occur consecutively, intra-cell handovers will be disallowed
in the cell for a certain period of time.

Maximum number of attempts to resend the downlink assignment messages

Number of attempts to re-establish the downlink TBF

This parameter specifies the largest step of each TRX power reduction.

Maximum number of TRXs that can be configured for one cell. For the
BTS3900B GSM, when the "Frequency and BSIC Plan Switch" is ON, the
"Maximum TRX Number" (one or two, one by default) can be selected. For the
BTS3900E GSM, when the "Capacity and Coverage Optimize Switch" is OFF, the
"Maximum TRX Number" (one or two, one by default) can be selected.
Maximum number of TRXs that can be configured for one cell. For the
BTS3900B GSM, when the "Frequency and BSIC Plan Switch" is ON, the
"Maximum TRX Number" (one or two, one by default) can be selected. For the
BTS3900E GSM, when the "Capacity and Coverage Optimize Switch" is OFF, the
"Maximum TRX Number" (one or two, one by default) can be selected.

Maximum multiplexing frame length.

Maximum number of BTSs that are allowed to concurrently download software


under a BSC

Maximum length of the PPP multiplexing frame


The value of this parameter cannot be less than the maximum PPPMUX subframe length (MUXMAXSFL). This parameter can be associated with the
maximum segment length of the MP to control whether to segment the
multiplexed MP. To enable the PPPMUX, the number of sub-frames must be
more than or equal to 2. The following condition must be met: wMuxMaxSfL <=
( wMuxMfl-8 )/2.
Maximum number of retries when the user logs in

Maximum capacity for storing the alarm log

Maximum output power of the diesel


If the number of the path retransmissions exceeds this value, the parameter is
deleted automatically. The value must be smaller than Association max retrans.
Retransmission times of Pb link check (LapdCheck) messages. When a BSC
sends a Pb link check message to an external PCU and fails to receive a
response from the external PCU, it retransmits the message. This parameter
indicates the maximum times for the PB link check message to be transmitted.

Maximum number of PDCHs that can be assigned in the TRX

Maximum value of the PDCH ratio in a cell. The number of available TCHs and
PDCHs in a cell is set to a fixed value. The PDCH ratio is: Number of available
PDCHs/(Number of available TCHFs + Number of available static PDCHs). This
parameter is used to restrict the PDCH ratio.

Maximum number of attempts to resend the polling messages

Expire Prompt Dates.

Maximum current coefficient when the battery is charged. When the battery is
charged, the maximum current can be 0.01 to 0.99 times of the capacity of the
battery cabinet. That is, the charge coefficient is 0.01-0.99. For example, if the
capacity of the battery cabinet is 200 A and the charge coefficient is 0.15, the
maximum charge current for the battery cabinet is 30 A.

Maximum current coefficient when the battery is charged. When the battery is
charged, the maximum current can be 0.05 to 0.25 times of the capacity of the
battery cabinet. That is, the charge coefficient is 0.05-0.25. For example, if the
capacity of the battery cabinet is 200 A and the charge coefficient is 0.15, the
maximum charge current for the battery cabinet is 30 A.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Maximum times for a Physical Information message to be transmitted. When


the retransmission times exceeds this parameter and the BTS still cannot
receive any correct SAMB frame from the MS, the BTS sends a connection
failure message (including the handover failure information) to the BSC, which
releases the assigned channel and stops timer T3105 after receiving this
message.
In a non-synchronized handover, an MS keeps sending Handover Access Burst
messages (usually, the value of timer T3124 is 320 ms) to the network. When
detecting these messages, the BTS returns a Physical Information message to
the MS through the main DCCH (FACCH) channel, starts timer T3105, and sends
a MSG_ABIS_HO_DETECT message to the BSC.
The BTS includes the information of different physical layers in the Physical
Information message, thus ensuring correct traffic transmission for the MS. If
the timer timeouts before a SAMB frame is received from the MS, the BTS
retransmits the Physical Information message to the MS.
For details, see protocols 08.58 and 04.08.

Maximum retransmission for radio priority 1. The 2bit Radio Priority message
carried by the MS in the Packet Channel Request message has four levels of
priorities. Level 1 is the highest priority, and level 4 is the lowest priority.
Maximum retransmission for radio priority 2. The 2bit Radio Priority message
carried by the MS in the Packet Channel Request message has four levels of
priorities. Level 1 is the highest priority, and level 4 is the lowest priority.
Maximum retransmission for radio priority 3. The 2bit Radio Priority message
carried by the MS in the Packet Channel Request message has four levels of
priorities. Level 1 is the highest priority, and level 4 is the lowest priority.
Maximum retransmission for radio priority 4. The 2bit Radio Priority message
carried by the MS in the Packet Channel Request message has four levels of
priorities. Level 1 is the highest priority, and level 4 is the lowest priority.

Maximum PPPMUX sub-frame length. If the PPP frame length is larger than this
value, the PPPMUX multiplexing is performed. The value of this parameter
cannot be larger than the maximum multiplexed frame length wMuxMfl. To
enable the PPPMUX, the number of sub-frames must be more than or equal to
2. The following condition must be met: wMuxMaxSfL <= ( wMuxMfl-8 )/2

Maximum length of the PPP multiplexing frame

Huawei power control algorithm II divides three quality zones according to the
quality of the receive signals. When the power is downwardly adjusted
according to the level, the maximum downward adjustment step can vary
according to the quality of the received signals. This parameter specifies the
maximum step of downward power adjustment when the quality of the
received signals falls into quality zone 0.

Huawei power control algorithm II divides three quality zones according to the
quality of the receive signals. When the power is downwardly adjusted
according to the level, the maximum downward adjustment step can vary
according to the quality of the received signals. This parameter specifies the
maximum step of downward power adjustment when the quality of the
received signals falls into quality zone 1.

Huawei power control algorithm II divides three quality zones according to the
quality of the receive signals. When the power is downwardly adjusted
according to the level, the maximum downward adjustment step can vary
according to the quality of the received signals. This parameter specifies the
maximum step of downward power adjustment when the quality of the
received signals falls into quality zone 2.
This parameter specifies the actual coverage area of a cell. After receiving the
channel request message or handover access message, the BTS determines
whether the channel assignment or handover is performed in the cell by
comparing the TA and the value of this parameter. The value of this parameter
is determined by that of "Cell Extension Type" in the "ADD GCELL" command.
Number of measurement reports (MRs) used for averaging the time advance
before the call drops
Whether to initiate a forcible call drop when the time advance exceeds "MAX TA
Drop Call Threshold"

Whether the time advance after filtering exceeds the threshold. If the threshold
is exceeded, a forcible call drop is initiated.

Maximum positioning time.


Maximum number of (16 kbit/s) Abis timeslots that the PDCHs can use in the
TRX
Maximum TTL value of the sent TRACERT packet

Step of upward power adjustment according to the quality of the received


signals

Maximum Valid Dates.


Detection index. The index is a unique value ranging from 0 to 31 if it is not
specified.
Local IP address for multi-hop BFD

Used for requesting the MS to report the measurement information of


neighboring cells in multiple frequency bands. This parameter is carried in the
system information 2ter and 5ter.

For the purpose of accurately reflecting the radio environment of a network,


filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of enhanced
measurement reports received on a signaling channel used to measure the
MEAN_BEP value.
For the purpose of accurately reflecting the radio environment of a network,
filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of enhanced
measurement reports received on a voice channel used to measure the
MEAN_BEP value.
Number of the BTS. The BTS is numbered uniquely in a BSC.

Name of the BTS. The BTS is named uniquely in a BSC.

Mobile country code. This parameter identifies the country where a mobile
subscriber is located, for example, the Chinese MCC is 460.

Local mobile country code (MCC). It is used to identify the country that the
mobile subscriber belongs to. For example, the MCC of China is 460.

Number of MC prioritie levels.

Number of MC priorities. This parameter is valid when the MP group type is MC.

Number of the cell. The cell is numbered uniquely in a BSC.

Name of cell 2

Cabinet No. of the management board. The management board refers to the
TMU or RXU that directly communicates with the board. The configuration of
this parameter must be consistent with the actual physical connection.
Otherwise, the board may not work properly.

If the MCPA Optimization Switch is turned on, the MCPA priority update mode is
adjusted.
Standard for the GSM multi-carrier BTS
Identifies a maintenance domain
Level of the maintenance domain.The priority of the maintenance domain ranks
from 0 to 7 from low to high.
name of the MD

Name of the maintenance domain.

Whether to allow the MS to the send the PS measurement report to the network
side
Common measurement period

Type of the measurement report (MR) reported by the MS

Identifies a maintenance point in the maintenance alliance


A maintenance point is an edge node of the MA.

Identifies a maintenance end point (MEP) of a maintenance association.

The type of the maintenance point added to the maintenance group. LocalMep
indicates a local maintenance point and RemoteMep indicates a remote
maintenance point.
Frame encapsulation format supported by MP/MC.

MP/MC sequence header option

Minimum receive level for a neighbor cell to become a candidate cell during cell
reselection. When the receive level of the serving cell is lower than the value of
this parameter, it indicates that the normal cell reselection level is bad. In this
case, the parameter value is used for the calculation of the times of the
occurrence of bad normal cell reselection level.

Minimum bandwidth for dynamic adjustment at the logical port

Selects 3G candidate cells. If the measured value of a 3G neighboring cell is


lower than this threshold, the 3G neighboring cell will be removed from among
the 3G candidate cells.

Minimum receive level offset.


An MS can be handed over to a neighboring cell only when the downlink level
of the neighboring cell is greater than the sum of "Min DL level on candidate
Cell" and the value of this parameter.

Threshold for triggering prompt alarm clearance when the ANT_A tributary
antenna current is too heavy. When the actual current is higher than the
configured value, the ALD Current Prompt Alarm clearance is triggered.
Threshold for triggering prompt alarm clearance when the ANT_B tributary
antenna current is too heavy. When the actual current is higher than the
configured value, the ALD Current Prompt Alarm clearance is triggered.
Warning alarm threshold against excessive TMA feed current of feed tributary 0.
When the actual current is greater than the specified value, a TMA feed current
warning alarm is generated.
Warning alarm threshold against excessive TMA feed current of feed tributary 1.
When the actual current is greater than the specified value, the TMA feed
current warning alarm is generated.
Warning alarm threshold against excessive TMA feed current of feed tributary 2.
When the actual current is greater than the specified value, the TMA feed
current warning alarm is generated.
Warning alarm threshold against excessive TMA feed current of feed tributary 3.
When the actual current is greater than the specified value, the TMA feed
current warning alarm is generated.
Warning alarm threshold against excessive TMA feed current of feed tributary 4.
When the actual current is greater than the specified value, the TMA feed
current warning alarm is generated.
Warning alarm threshold against excessive TMA feed current of feed tributary 5.
When the actual current is greater than the specified value, the TMA feed
current warning alarm is generated.
Threshold for triggering prompt alarm clearance when the ANT_A tributary
antenna current is too heavy. When the actual current is lower than the
configured value, the ALD Current Prompt Alarm clearance is triggered.
Threshold for triggering prompt alarm clearance when the ANT_B tributary
antenna current is too heavy. When the actual current is lower than the
configured value, the ALD Current Prompt Alarm clearance is triggered.
In a direct retry, when the receive level of a neighboring cell is no smaller than
this parameter, the neighboring cell can be a candidate cell for the direct retry.
The parameter is invalid in handover algorithm II.

Minimum time required for a TCH to transform to a SDCCH and then transform
back to a TCH

Selects 3G candidate cells. If the measured value of a 3G neighboring cell is


lower than this threshold, the 3G neighboring cell will be removed from among
the 3G candidate cells.

Minimum interval at which two BFD packets are received.


Minimum interval at which the BTS receives BFD packets

Minimum interval between sent BFD packets

Minimum interval at which the BTS sends BFD packets

Mirror destination Ethernet port number

Mirror Ethernet port number

Mirror type

Mobile network code. This parameter identifies the public land mobile network
(PLMN) to which a mobile subscriber belongs.

Mobile network code (MNC). It is used to identify the PLMN that the mobile
subscriber belongs to.
Usage threshold of the CPU for calling access. If the usage of the CPU exceeds
the threshold, the calling access request is transferred to other CPU for
processing.
SCTP link work mode. Server mode: BSC6900 starts the listening and waits for
the peer to send the SCTP-INIT message. Client mode: BSC6900 actively sends
the SCTP-INIT message.
Working mode of a port. When this parameter is set to
CHECK_ON_STANDBY_PORT, the connectivity check is performed on the standby
port. When this parameter is set to CHECK_ON_INDEPENDENT_PORT, the
connectivity check is performed on the independent port. When this parameter
is set to CHECK_ON_PRIMARY_PORT, the connectivity check is performed on the
active port.

Working mode of the system clock. Working modes of the system clock are as
follows:
(1) MANUAL: In this mode, you must specify a clock source and prevent the
switching of the clock source.
(2) AUTO: In this mode, you do not need to specify a clock source and the
system automatically selects the clock source with the highest priority.
(3) FREE: In this mode, the crystal oscillator of board is used.

Configuration mode

Working mode after switchover

Mode of file output.

Backup mode of the switch protection group

Alarm mode of feed tributary 0. There are three alarm modes.


Alarm mode 1 has only one type of alarms. The alarm current is fixed and
greater than the normal working current.
Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The
alarm current is fixed and greater than the normal working current.
Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The
warning alarm current is periodical pulse current, while the critical alarm
current is fixed.

Alarm mode of feed tributary 1. There are three alarm modes.


Alarm mode 1 has only one type of alarms. The alarm current is fixed and
greater than the normal working current.
Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The
alarm current is fixed and greater than the normal working current.
Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The
warning alarm current is periodical pulse current, while the critical alarm
current is fixed.

Alarm mode of feed tributary 2. There are three alarm modes.


Alarm mode 1 has only one type of alarms. The alarm current is fixed and
greater than the normal working current.
Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The
alarm current is fixed and greater than the normal working current.
Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The
warning alarm current is periodical pulse current, while the critical alarm
current is fixed.

Alarm mode of feed tributary 3. There are three alarm modes.


Alarm mode 1 has only one type of alarms. The alarm current is fixed and
greater than the normal working current.
Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The
alarm current is fixed and greater than the normal working current.
Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The
warning alarm current is periodical pulse current, while the critical alarm
current is fixed.

Alarm mode of feed tributary 4. There are three alarm modes.


Alarm mode 1 has only one type of alarms. The alarm current is fixed and
greater than the normal working current.
Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The
alarm current is fixed and greater than the normal working current.
Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The
warning alarm current is periodical pulse current, while the critical alarm
current is fixed.

Alarm mode of feed tributary 5. There are three alarm modes.


Alarm mode 1 has only one type of alarms. The alarm current is fixed and
greater than the normal working current.
Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The
alarm current is fixed and greater than the normal working current.
Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The
warning alarm current is periodical pulse current, while the critical alarm
current is fixed.

Monitoring period

Monitoring duration

Month when the TMU board software is released


A quick handover can be initiated only if the rate of an MS is higher than this
parameter during a certain period of time.
When the number of error frames on the MP group reaches the value of this
parameter, the frame error alarm is generated.

When the number of error frames on the MP group decreases to the value of
this parameter, the frame error alarm is cleared.

Number of an MLPPP group on a BTS. It is unique in a BTS. The scope of the


number of th MLPPP group in the BTS3900 series is 0~1.

MP group number

MP group number
A BTS supports the following six types of timeslot objects:
OML: operation and maintenance link of the BTS. Each BTS has only one OML.
In the case of statistical multiplexing on a 64 kbit/s timeslot, the OML works at
64 kbit/s. In this case, the OML can be multiplexed only with the signaling links
in the same cabinet group of the BTS. In the case of physical multiplexing on a
16 kbit/s timeslot, the OML works at 16 kbit/s. In this case, the OML uses a 16
kbit/s timeslot.
ESL: extended signaling link of the BTS. If the BTS supports Flex Abis, in the
case of statistical multiplexing on a 64 kbit/s timeslot, a 64 kbit/s timeslot
needs to be assigned to the ESL. In this case, the ESL is always multiplexed
with the OML in the 64 kbit/s timeslot. In the case of physical multiplexing on a
16 kbit/s timeslot, no timeslot is assigned to the ESL. In this case, the ESL
shares the same timeslot with the OML.
RSL: radio signaling layer link in each TRX. Each TRX has one RSL link. In the
case of statistical multiplexing on a 64 kbit/s timeslot, the RSL link works at
64kbit/s. In this case, the RSL link can be multiplexed only with the signaling
links in the same cabinet group of the BTS. In the case of physical multiplexing
on a 16 kbit/s timeslot, the RSL link works at 16 kbit/s. In this case, the RSL link
uses a 16 kbit/s timeslot exclusively.
TCH: traffic channels in each TRX. The TCH works at 16 kbit/s.
Idle: idle timeslots of the BTS. An idle timeslot works at 16 kbit/s. In the case of
statistical multiplexing on a 64 kibt/s timeslot, the idle timeslots can be
multiplexed only with the TCHs in the same cabinet group onto one 64 kbit/s
timeslot.
Semi: monitoring timeslots of the BTS. The monitoring timeslots work at 8
kbit/s, 16 kbit/s, 32 kbit/s, and 64 kbit/s. The monitoring timeslots can be
multiplexed only with semi-permanent links.
A 2048 Mbit/s E1 contains thirty-two 64 kbit/s timeslots. Timeslot 0 is reserved
for synchronization and cannot be assigned.
Statistical multiplexing means that signaling timeslots are time-division
multiplexed in an E1 timeslot, such as the OML and RSL timeslots or the RSL
timeslots. For example, in the case of 4:1 multiplexing, one 64 kbit/s timeslot

Number of the serial port where the board is located. The management board
refers to the TMU or RXU that directly communicates with the board. The
configuration of this parameter must be consistent with the actual physical
connection. Otherwise, the board may not work properly.

Is Support MCPPP.

MP type

Number of the slot where the MPU subsystem is located

Number of the subrack where the MPU subsystem is located

Whether power control algorithm II allows measurement report compensation.


When making a power control decision, the BSC retrieves a certain number of
history measurement reports and performs weighted filtering on the receive
level values and receive quality values in these reports, which may be obtained
when different transmit powers were used by BTSs or MSs. To ensure that
correct receive level values and receive quality values are used in filtering, you
must compensate the receive level values and receive quality values in history
measurement reports obtained when transmit powers different than the current
one were used.

If the number of measurement reports lost consecutively is no larger than this


value, linear interpolation is performed for the values in the lost measurement
reports based on the values in the two measurement reports preceding and
following the lost measurement reports. Otherwise, the lost measurement
reports will be discarded, and the value will be recalculated when new
measurement reports arrive.

When the number of the lost measurement reports exceeds this parameter
during a power control period, the power control stops.

Frequency at which the BTSs submit pre-processed measurement reports to the


BSC
Attenuation factor for the TMA of antenna tributary 1

Attenuation factor for the TMA of antenna tributary 2


Switch of measurement report collection within a specified scope. If the
specified scope is a site, the switch applies to all the cells at the site; if the
specified scope is a cell, the switch applies to the cell only. The switch of
measurement report collection within a specified scope last configured takes
effect.
The control switch of measurement report collection includes OFF (do not
collect), ON_WITH_SDCCH (collect measurement reports for SDCCHs and TCHs),
and ON_WITHOUT_SDCCH (collect measurement reports for TCHs only).

Maximum length of a received packet. The value of this parameter is


negotiated at both ends of a communication.

Number of MSs used when the offset information is collected


Whether to collect the information about the MSs of different capabilities in a
cell. This parameter has no impact on services.
Available capacity of the MSC. This parameter is valid only when the MSC pool
function is enabled. It is set according to the actual capacity of the MSC.
Number of bits occupied by the Network Resource Identifier in the TMSI. NRI
specifies a CN node in the MSC pool.
Special NRI(Network Resource Identifier) that is coded together with common
NRIs. This parameter is used to indicate that the BSC routes the service
initiated by the MS to the MSC in non OFFLOAD state.

Whether to enable the MSC pool function on the BSC6900.


The MSC pool function enables up to 32 MSCs to provide services for mobile
subscribers in a BSC6900. With the MSC pool function, one BSC6900 can be
connected to multiple MSCs and the services in the BSC6900 are shared to
each MSC in all MSC pools.
Administrative state of the MSC. This parameter is valid only when the MSC
pool function is enabled. It is set according to the actual operating state of the
MSC. A call accesses the MSC only when this parameter is set to NORMAL.
Protocol version of the MSC that is connected to the BSC6900. The supported
signaling varies with the protocol versions.

Call reestablishment timer

MSISDN value

MSISDN prefix 1. When matching the call specified by the mobile number, the
BSC6900 adds the MSISDN prefix 1 according to the value of this parameter.
For example, when the value of this parameter is 123 and the mobile number
to be matched is 456, the call matching is considered successful if the
corresponding MSISDN is 123456.
MSISDN prefix 2. When matching the call specified by the mobile number, the
BSC6900 adds the MSISDN prefix 2 according to the value of this parameter.
For example, when the value of this parameter is 123 and the mobile number
to be matched is 456, the call matching is considered successful if the
corresponding MSISDN is 123456.
MSISDN prefix 3. When matching the call specified by the mobile number, the
BSC6900 adds the MSISDN prefix 3 according to the value of this parameter.
For example, when the value of this parameter is 123 and the mobile number
to be matched is 456, the call matching is considered successful if the
corresponding MSISDN is 123456.

MSISDN prefix 4. When matching the call specified by the mobile number, the
BSC6900 adds the MSISDN prefix 4 according to the value of this parameter.
For example, when the value of this parameter is 123 and the mobile number
to be matched is 456, the call matching is considered successful if the
corresponding MSISDN is 123456.
MSISDN prefix 5. When matching the call specified by the mobile number, the
BSC6900 adds the MSISDN prefix 5 according to the value of this parameter.
For example, when the value of this parameter is 123 and the mobile number
to be matched is 456, the call matching is considered successful if the
corresponding MSISDN is 123456.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.

If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.

If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.

If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in
the MSISDN of the called or calling are the same as the value of this parameter,
the BSC local switching function is enabled. For example, if two numbers 135
and 139 are set in the list, and the first three digits in the MSISDN of the called
or calling are 135 or 139, the BSC local switching function is enabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BSC local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BSC local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BSC local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BSC local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BSC local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BSC local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BSC local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BSC local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BSC local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BSC local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BTS local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BTS local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BTS local switching function is disabled.

If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BTS local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BTS local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BTS local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BTS local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BTS local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BTS local switching function is disabled.
If the first digits in the MSISDN of the called or calling are the same as the value
of this parameter, the BTS local switching function is disabled.
Whether to enable "Triggering the quick PBGT algorithm only when an MS is far
from the BTS"
Maximum number of Channel Request messages that can be sent by an MS in
an immediate assignment procedure.
After the MS initiates the immediate assignment procedure, it always listens to
the messages on the BCCH and all the common control channels (CCCHs) in the
CCCH group to which the MS belongs. If the MS does not receive Immediate
Assignment or Immediate Assignment Extend messages, it retransmits Channel
Request messages at a specified interval.
If the downlink quality is poor, the MS may send SABM frames to the BTS
multiple times.

Control command of the MSP switchover protection group

Threshold of the MS Receiver Diversity (MSRD) mode

PDCH Downlink multiplex threshold in the Mobile Station Receiver Diversity


(MSRD) mode. When this parameter is set to "80", the MS does not adopt the
MSRD mode. When the number of the TBF on the PDCH that is assigned to the
MS exceeds this parameter or the coding rate of the PDCH is smaller than the
threshold of the coding rate in MSRD mode, the MS is required to adopt the
MSRD mode.

Number of the subrack where the board is located. The management board
refers to the TMU or RXU that directly communicates with the board. The
configuration of this parameter must be consistent with the actual physical
connection. Otherwise, the board may not work properly.

The M criteria supports setting minimum values for the downlink receive level
of neighboring cells.
The M criteria is met only when ,
Estimated downlink level of neighboring cells >= ("Min DL level on candidate
Cell" + "Min Access Level Offset")
Estimated uplink level of neighboring cells >= ("Min UL level on candidate Cell"
+ "Min Access Level Offset")
When the number of received measurement reports on the downlink
transmission quality (Packet Downlink Ack/Nack message) is greater than or
equal to this threshold, emergency reselection decision is made.
Duration of the flow control timer F of the MS. The MS sends the flow control
message according to this duration.
If no handshake message is received from the peer within the delay, the master
service is activated. A master service object provides services at the local BSC
and its configuration data is backed up at the peer BSC. A master service object
provides services at the peer BSC only when the local BSC is faulty or when all
the signaling links on the A interface of the local BSC are faulty.

Maximum TX power for the MS to access the PCH


Switch for the self-healing of the OMU when the OMU process memory is
overloaded

Usage threshold of the CPU for called access. If the usage of the CPU exceeds
the threshold, the called access request is transferred to other CPU for
processing.
Detection method
Identify an MTP2 link
Metric system. The values of this parameter include "MET" and "IMP".

Maximum transport unit

Maximum size of a packet that can be transmitted or received on a FE port.

Maximum transmission unit

Bus voltage of the battery rack of the BTS


Multi-band point report value, including "report six cells with the strongest
signal at each frequency point", "report one cell with the strongest signal at
each frequency point","report two cells with the strongest signal at each
frequency point", and "report three cells with the strongest signal at each
frequency point".
Period of performing class-1 mute detection. If the bad frame rate reaches "Bad
Frame Threshold of Mute Detection Class 1" within the period specified by this
parameter, mute speech may be detected. The setting of "Mute Detection Class
2 Switch" determines whether to perform the class-2 mute detection.
Whether the one-way audio problem is checked in class-2 detection. In this
manner, the one-way audio problems found in class-1 are checked to ensure
the accuracy.

Period of performing the class-2 mute detection. After the BTS or TC initiates a
class-2 mute detection request, the class-2 mute detection fails if there is no
response and no test TRAU frame is received by the end of the period specified
by this parameter; if the class-2 mute detection response is received but no
correct test TRAU frame is received, mute speech is detected; if the class-2
mute detection response and the expected test TRAU frame are received, the
speech channel is considered to be normal.
Time for prohibiting the call from accessing the corresponding channel where
one-way audio is detected on the Abis interface.
Whether to forcibly release a call after the forced handover fails in the case of
one-way audio on the Abis interface

Maximum time waiting for multiplexing

Frame timeout duration of the PPP multiplexing group

IP packet multiplexing type

Minimum number of reserved working status TRXs of the cabinet


BFD local description mark

System parameter in the LAPD protocol. The value of this parameter specifies
the maximum number of times when a frame is retransmitted.

Error control is performed on the I frame sent over the LAPDm layer between
the BTS and MS. If the MS detects errors in an I frame, the BTS should resend
the I frame. This parameter indicates the maximum number of retransmissions
of the I frame.
For the function of N200 and the effect of the parameter, see the description of
"T200 SDCCH".
Error control is performed on the I frame sent over the LAPDm layer between
the BTS and MS. If the MS detects errors in an I frame, the BTS should resend
the I frame. This parameter indicates the maximum number of retransmissions
of the I frame on the FACCH (a full-rate channel).
For the function of N200 and the effect of the parameter, see the description of
"T200 SDCCH".

Error control is performed on the I frame sent over the LAPDm layer between
the BTS and MS. If the MS detects errors in an I frame, the BTS should resend
the I frame. This parameter indicates the maximum number of retransmissions
of the I frame on the FACCH (a half-rate channel).
For the function of N200 and the effect of the parameter, see the description of
"T200 SDCCH".

Whether the BSC6900 sends the LAPDm N200 parameter to the BTS.
If this parameter is set to YES, the BSC sends the LAPDm N200 parameter. If
this parameter is set to NO, the BSC6900 does not send the LAPDm N200
parameter.

Error control is performed on the I frame sent over the LAPDm layer between
the BTS and MS. If the MS detects errors in an I frame, the BTS should resend
the I frame. This parameter indicates the maximum number of retransmissions
of the I frame during the multi-frame release.
For the function of N200 and the effect of the parameter, see the description of
"T200 SDCCH".
Error control is performed on the I frame sent over the LAPDm layer between
the BTS and MS. If the MS detects errors in an I frame, the BTS should resend
the I frame. This parameter indicates the maximum number of retransmissions
of the I frame on the SACCH.
For the function of N200 and the effect of the parameter, see the description of
"T200 SDCCH".

Error control is performed on the I frame sent over the LAPDm layer between
the BTS and MS. If the MS detects errors in an I frame, the BTS should resend
the I frame. This parameter indicates the maximum number of retransmissions
of the I frame on the SDCCH.
For the function of N200 and the effect of the parameter, see the description of
"T200 SDCCH".
Maximum value of the N3101 counter. In the dynamic uplink allocation mode,
the network side enables multiple MSs to share the same uplink channel
through the USF value in the downlink data block. After the network side
allocates the USF to the uplink TBF (the uplink TBF is set up successfully),
N3101 is started. The network side waits for the RLC uplink data block sent by
the MS. If the RLC uplink data block sent by the MS is valid, N3101 is reset.
Otherwise, the value of N3101 is increased on the network side. When this
counter is overflowed, the current uplink TBF is released abnormally.

Maximum value of the N3101 counter. When the uplink transmission ends, if
the network side receives the last RLC data block, the network side sends an
FAI=1 uplink packet acknowledged/unacknowledged message and starts
N3103. If the packet control acknowledgement message is not received in the
specified time, N3103 is increased on the network side and the uplink packet
acknowledged/unacknowledged message is retransmitted. When this counter is
overflowed, the timer T3169 is started. After this timer expires, the current TBF
is released abnormally.

Maximum value of the N3105 counter. After the downlink TBF is set up
successfully, the N3105 is started on the network side. After the downlink RLC
data block is added with the RRBP domain on the network side, the valid packet
acknowledged message responded by the MS is received in the uplink RLC data
block in the RRBP domain. In this case, N3105 is reset. Otherwise, the value of
N3105 is increased and the downlink data block of the RRBP is retransmitted.
When N3105 is overflowed, T3195 is started. After the timer T3195 expires, the
current TBF is released abnormally.
Counter on the DTE side. After BC link integrity is verified according to
"Parameter of DTE [N391]", the global state query request is originated on the
DTE side.

Counter on the DTE side, recording the checking times "Parameter of DTE
[N393]". After BC link integrity is verified according to "Parameter of DTE
[N392]", the BC link state is restored. That is: if the BC link state on the DTE
side is failure, and the system is found normal in the checking times "Parameter
of DTE [N392]" out of the checking times "Parameter of DTE [N393]", the BC
link state is switched to the normal state. If the BC link state operates normally
on the DTE side, and the system is found faulty in the checking times
"Parameter of DTE [N392]" out of the checking times "Parameter of DTE
[N393]", the BC link state is switched to the faulty state. "Parameter of DTE
[N392]" must be smaller than "Parameter of DTE [N393]".

Counter on the DTE side, recording the checking times "Parameter of DTE
[N393]". After BC link integrity is verified according to "Parameter of DTE
[N392]", the BC link state is restored. That is: if the BC link state on the DTE
side is failure, and the system is found normal in the checking times "Parameter
of DTE [N392]" out of the checking times "Parameter of DTE [N393]", the BC
link state is switched to the normal state. If the BC link state operates normally
on the DTE side, and the system is found faulty in the checking times
"Parameter of DTE [N392]" out of the checking times "Parameter of DTE
[N393]", the BC link state is switched to the faulty state. "Parameter of DTE
[N393]" must be greater than "Parameter of DTE [N392]".

Whether to support the network assisted cell change (NACC). The NACC is used
in the network control modes NC0, NC1 or NC2. The NACC enables the network
to notify the MS of the system information of the neighboring cell when the MS
is in the packet transmission state. In this way, the MS can reselect a cell in a
shorter time.

Name of the OSP

Name of the DSP

Name of an MTP3 route

Name of the signalling link set

Name of the MTP3 link

Local entity name. The local entity name must be unique.

Name of the destination entity


The M3UA route names and the M3UA routes are in the one-to-one matching
relation.
Name of the M3UA link set. The name of the M3UA signalling link set must be
unique.
M3UA signaling link name. The M3UA link names and the M3UA links are in the
one-to-one matching relation.
Name of the PCU

Name of the adjacent node


Whether to preferentially allocate loose multiplexing frequencies to non-AMR
users
Filter consistent of the collision signal strength of power control. When sampling
must be performed (NAVGI) times before the MS obtains the efficient
measurement signal.
Whether to enable the Tandem Free Operation (TFO) function on the BTS
through a CHANNEL ACTIVATION or MODE MODIFY message. This parameter
specifies whether to enable the Tandem Free Operation (TFO) function. If the
voice quality of an ongoing MS-to-MS call is bad, the TFO function can be
enabled to improve end-to-end voice quality. The TFO function cannot be used
to improve the voice quality of an MS-to-PSTN call.
Uniform number of neighboring cell 1 index within a BSC6900, which uniquely
identifies a cell and is in the range 0 to 5047.
Name of neighboring GSM cell 1
Index of neighboring GSM cell 2. Uniform number of a cell index within a
BSC6900, which uniquely identifies a cell and is in the range 0 to 5047.

Name of neighboring GSM cell 2


Uniform number of a cell index within a BSC6900
, which uniquely identifies a cell.
Name of a cell
Uniform number of a neighboring cell index within a BSC, which uniquely
identifies a cell.
The value range of the index of a 3G external cell is 5048 to 8047.
Name of a neighboring cell
When this switch is on, it indicates that the data of the adjacent cell is
generated automatically. When this switch is off, it indicates that these data
must be configured manually.
Cell ID of a neighboring cell

Local Area Code (LAC) of a neighboring cell

Mobile Country Code (MCC) of a neighboring cell

Mobile Network Code (MNC) of a neighboring cell


Whether the PCU of the cell supports the 64 neighboring cells.
This parameter determines the capability of reporting the number of the
neighboring cells of the BSC in the NACC and NC2 function.
Whether to involve the load of the target cell in the algorithm for NC2 cell
reselection. If this parameter is set to Support, the load of the target cell is
involved in the algorithm for NC2 cell reselection.
Whether to support the network control 2 (NC2). The NC2 enables the network
side to control the cell reselection for the MS when the MS reports the
measurement report of the local cell and the neighboring cell.When this
parameter is set to "YES" and "Network Control Mode" in "SET GCELLPSBASE" is
set to "NC2", the network side can control the cell reselection for the MS.

Network color code that is provided by the telecom operator. The NCC is used
to identify networks from area to area. The NCC is unique nationwide.
The BCC and the NCC form the BSIC.
Network color code. It is used to uniquely identify different public land mobile
network (PLMN) of the adjacent country.

A set of NCCs of the cells to be measured by the MS. This parameter is an


information element (IE) in the system information type 2 and 6 messages.
If a bit of the value of this parameter is set to 1, the MS reports the
corresponding measurement report to the BTS. The value of this parameter has
a byte (eight bits). Each bit maps with an NCC (0~7) and the most significant
bit corresponds to NCC 7. If bit N is 0, the MS does not measure the cell level of
NCC N.

NCC bitmap of the measurement report sent by the MS. The MS reports only
the NCC bitmap of the BSIC and the cell measurement report that matches the
bitmap.
For the purpose of accurately reflecting the radio environment of a network,
filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of measurement
reports used for the filtering of neighboring cell information.

For the purpose of accurately reflecting the radio environment of a network,


filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of measurement
reports used for the filtering of neighboring cell signal strength.

Neighboring cell interference level threshold 0

Neighboring cell interference level threshold 1

Neighboring cell interference level threshold 2

Neighboring cell interference level threshold 3

Neighboring cell interference level threshold 4

Neighboring cell interference level threshold 5

Neighboring cell interference level threshold 6

Neighboring cell interference level threshold 7

Number of blocks occupied by the NCH in the group call service

Number of the start block occupied by the NCH in the group call service

Network control mode for cell reselection of the MS. There are three modes.
NC0: normal MS control. The MS shall perform autonomous cell re-selection.
NC1: MS control with measurement reports. The MS shall send measurement
reports to the network and the MS shall perform autonomous cell re-selection.
NC2: network control. The MS shall send measurement reports to the network .
The MS shall only perform autonomous cell re-selection when the reselection is
triggered by a downlink signaling failure or a random access failure.When this
parameter is set to NC2 and "Support NC2" in "SET GCELLGPRS" is set to "YES",
the network side can control the cell reselection for the MS.

The DSP and OSP are in the associated mode or non associated mode.

IP address mask of the VLAN

Minimum interval between two consecutive emergency handovers performed


by an MS. During this interval, no emergency handover is allowed.

IP address of the next hop

IP address of the next hop


Next hop
Next hop
Network ID

Name of the file to be downloaded. The file name must be complete and does
not contain a wildcard.
This parameter is related to the paging channel of the system. There are three
network operation modes: network operation mode I, network operation mode
II, and network operation mode III. Network operation mode I is used when the
system is configured with the Gs interface. Network operation mode II is used
when the system is not configured with the Gs interface and the PCCCH is not
configured. Network operation mode III is used when the system is not
configured with the Gs interface and the PCCCH is configured.

No Mains Supply Alarm Cabinet No.

No Mains Supply Alarm Port No.

No Mains Supply Alarm Slot No.

No Mains Supply Alarm Subrack No.

Lower limit of input voltage 1

Upper limit of input voltage 1

Lower limit of input voltage 2

Upper limit of input voltage 2

Lower limit of input voltage 3

Upper limit of input voltage 3

Lower limit of input voltage 4

Upper limit of input voltage 4

Lower limit of input voltage 5

Upper limit of input voltage 5

Lower limit of input voltage 6

Upper limit of input voltage 6

Whether to allow non-AMR voice F-H handover

Decides the offset of the current ATCB together with other two parameters: "F-H
Ho Period" and period of triggering a F-H handover, thus selecting target users
for F-H handovers. ATCB offset = (Period of triggering a F-H handover / "F-H Ho
Period" + 1) * "Non-AMR F-H Ho ATCB Adjust Step".

When the ATCB value of non-AMR full rate voice is no smaller than this
parameter, the condition for non-AMR F-H handovers is met.

Decides the current path cost offset together with other two parameters: "F-H
Ho Period" and period of triggering a F-H handover, thus selecting target users
for F-H handovers.
Path cost offset = (Period of triggering a F-H handover / "F-H Ho Period" + 1) *
"Non-AMR F-H Ho Pathloss Adjust Step".

When the path loss value of non-AMR full rate voice is no larger than this
parameter, the condition for non-AMR F-H handovers is met.

Quality threshold for non-AMR F-H handovers. When the uplink receive quality
and downlink receive quality of a user are both smaller than this parameter, a
F-H handover is triggered for the user.

When the load of a cell is no smaller than this threshold, non-AMR F-H
handovers are triggered in the cell.

When the ATCB value of non-AMR half rate voice is no larger than this
threshold, the condition for non-AMR H-F handovers is met.

When the path loss value of non-AMR half rate voice is no smaller than this
threshold, the condition for non-AMR H-F handovers is met.

Whether to trigger non-AMR H-F handovers according to the uplink and


downlink receive quality

Quality threshold for non-AMR H-F handovers. When the receive quality of a
user is no smaller than this parameter, the user meets the condition for H-F
handovers.

When the load of a cell is no larger than this threshold, non-AMR H-F handovers
are triggered in the cell.

Type of the adjacent node


Decisions of no-downlink measurement report handovers can be made only
when the number of consecutive no-downlink measurement reports in the
current call is no larger than this parameter.
Whether to enable the no-downlink measurement report handover algorithm

When a certain number of no-downlink measurement reports are received


consecutively and the uplink receive quality is no smaller than this parameter,
no-downlink measurement report emergency handovers are triggered. Nodownlink measurement report emergency handovers choose the inter-cell
handover mode preferentially; however, if no candidate cells are available and
intra-cell handover is enabled in the current cell, intra-cell handovers are
triggered.

Normal output capacity of the battery group in specific discharging conditions


(such as discharge rate, temperature, and final voltage). Generally, the
parameter is based on 10-hour discharge rate.
Whether to enable the III power control algorithm for Non-AMR calls. If enabled,
power control is performed on Non-AMR calls.

Period when the cell is in the non-DRX state


When the ANT_A tributary antenna current abnormally check mode is set to
Mode 3, the parameter ALD Current Prompt Alarm is checked by periodical
pulse. The periodical pulse consists of antenna over-current duration and
normal current duration. This parameter is the ANT_A tributary antenna normal
current duration.
When the ANT_B tributary antenna current abnormally check mode is set to
Mode 3, the parameter ALD Current Prompt Alarm is checked by periodical
pulse. The periodical pulse consists of antenna over-current duration and
normal current duration. This parameter is the ANT_B tributary antenna normal
current duration.
Whether to allow the cell normal reselection. If this parameter is set to PERMIT
and "NC2 Load Reselection Switch" is set to Support, the load of the target cell
is involved in the algorithm for NC2 cell reselection.
Normal work temperature threshold of the cabinet
Whether to discard paging messages without TMSIs and all-cell paging
messages that considerably increase the load on the BSC system
Maximum number of measurement periods in which there is no traffic. If the
number of measurement periods in which there is no traffic reaches this
parameter, the BTS reports an alarm indicating that there is no traffic.
If the BTS works in fallback mode and uplink VGCS connection is idle for a
period specified by this parameter, the BTS disables the VGCS connection
automatically. This parameter is valid only for user-originated VGCS calls and is
invalid for fixed VGCS calls.
Number of TRACERT packets sent to each TTL
For the purpose of accurately reflecting the radio environment of a network,
filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of enhanced
measurement reports received on a signaling channel used to filter the
NBR_RCVD_BLOCKS value.

For the purpose of accurately reflecting the radio environment of a network,


filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of enhanced
measurement reports received on a service channel used to filter the
NBR_RCVD_BLOCKS value.
Network resource indication that specifies a CN node in the MSC pool
Identifies the mapping relation from the NRI to the SGSN uniquely with the
operator name
Controls the values of the FDD_Indic0 field, the NR_OF_FDD_CELLS field, and
the FDD_Cellinformation field in 2quater and MI when 3G neighboring cells with
scrambling code 0 are present.
When this parameter is set to YES, FDD_Indic0 is set to 1, the
NR_OF_FDD_CELLS count does not include cells with scrambling code 0, and
FDD_Cellinformation also does not include cells with scrambling code 0;
When this parameter is set to NO, FDD_Indic0 is set to 1, the
NR_OF_FDD_CELLS count includes cells with scrambling code 0, and
FDD_Cellinformation also includes cells with scrambling code 0.

Identifies a unique NSE

The identifier of a network service entity (NSE).An NSE manages a group of


NSVCs.
For the purpose of accurately reflecting the radio environment of a network,
filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of measurement
reports received on signaling channels used for the filtering of neighboring cell
signal strength.
Whether the cell is located in the south latitude or north latitude
NSVC ID, identifies a unique NSVC. This ID must be negotiated with the peer
SGSN.

NSVC index, identifies a unique NSVC.

If the inlet temperature is between "High Temperature Critical Point" and "Low
Temperature Critical Point" and the difference between the inlet temperature
and the ambient temperature reaches the value of this parameter, the
temperature control system controls the difference between the inlet and outlet
temperatures as well as the difference between the inlet temperature and the
ambient temperature.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

If the outlet temperature is between "High Temperature Critical Point" and "Low
Temperature Critical Point" and the difference between the outlet temperature
and the inlet temperature reaches the value of this parameter, the temperature
control system controls the difference between the inlet and outlet
temperatures as well as the difference between the inlet temperature and the
ambient temperature.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Number of retransmissions of the VGCS UPLINK GRANT message

Ratio of the minimum guarantee bandwidth of the OAM stream to the port
bandwidth

Minimum guarantee bandwidth of the OAM stream

Minimum guarantee bandwidth of the OAM stream

Minimum guarantee bandwidth of the OAM stream


Ratio of the minimum guarantee bandwidth of the OAM stream to the port
bandwidth
DSCP value of the OAM stream. The data of the OAM stream are not added to
queues 0 to 5 for transmission. Instead, the data of the OAM stream is added to
the dedicated queue.

Minimum guarantee bandwidth switch of the OAM stream

Type of the object

Operation object
This parameter indicates the object index.
Index of object

Shield type of the alarm. "ALL" indicates one shield type instead of all types.

Type of the alarm shield object

Object index types used when commands are executed

When the PDCHs are insufficient, the streaming service with high priority can
preempt the PDCHs that are seized by the streaming service with low priority.
After the PDCH resource preemption, the streaming service with low priority
initiates the QoS negotiation with the SGSN. If the QoS negotiation fails, or if all
the PDCHs are preempted, then the streaming service with low priority is
disrupted.

Whether to allow overlay-to-underlay handovers

This parameter specifies whether to configure the backup OML. When YES is
configured in the BTS, an OML is configured in timeslot 31 of port 0 and port 1
respectively. The links are established on the two ports in turn after the BTS is
reset. Once the OML is established on a port, it is always used unless the BTS is
reset or the OML is disconnected. If the established OML is disconnected, the
BTS automatically switches the OML over to another port to re-establish the
OML.

If OML Detection Switch is set to OFF, then the OML timeslot automatic
detection is not supported. In this case, the OML is carried on the default
timeslots. If OML Detection Switch is set to ON, then the OML timeslot
automatic detection is supported. In this case, you can run the "SET BTSOMLTS"
command to allocate the OML to the specified timeslots.

This parameter specifies the detecting time of Abis-Bypass site OML when it is
broken.

Differentiated service code of the specified OML

The summation of average down-bandwidth of OML&ESL link in BTS.

The summation of average up-bandwidth of OML&ESL link in BTS.

Service priority of the specified OML


Priority of services on the OML. The operation and maintenance link (OML) is
used to transfer the OM information between the BSC6900 and BTS. This
parameter indicates the priority of services on the OML.0 is the highest priority.
Specified OML Vlan Id

Size of the OML/ESL/EML Downlink LAPD window

External virtual IP address of the OMU

Subnet mask of the OMU in the external network

Account of the operator

Code of the original signaling point (OSP) in the signaling network. In the
signaling network, each signaling point is identified by a signaling point code.
Code of the signaling point of the local office in the signaling network. In the
signaling network, each signaling point has a corresponding signaling point
code.
Uniquely identifies an OSP. see "ADD OPC" command.
Primary operator or secondary operator.
Primary operator is an operator that provides equipment, whereas secondary
operator is an operator that leases equipment.
Index of the operator. This parameter uniquely identifies an operator.

Operator index set to which the CBC belongs


It is one key filed of identifying A interface CIC status and indicates the
alignment mode of A interface circuit.

It is one key filed of identifying A interface timeslot status and indicates the
alignment mode of A interface circuit.

It is one key filed of identifying Ater interface timeslot status and indicates the
alignment mode of Ater interface circuit.

In the normal mode, if the board cannot be reset, no operation is performed. In


the force mode, if the board cannot be reset, the operation is performed by
force.
It is one key filed of identifying Pb interface CIC status and indicates the Pb
interface CIC.

Name of the operator. This parameter uniquely identifies an operator

Channel assignment policies used when TCHs are assigned in an IUO cell:
SysOpt: The system selects the preferentially-assigned service layer and
assigns channels according to the measurement reports on SDCCHs; USubcell:
preferentially assigns the TCHs on the underlay; OSubcell: preferentially assigns
the TCHs on the overlay; NoPrefer: use the normal channel assignment
algorithm to assign channels.
Preferentially assigns channels on the overlay when the uplink receive level on
the SDCCH is no smaller than "Assign-optimum-level Threshold" and the TA is
smaller than "TA Threshold of Assignment Pref"; otherwise, assigns channels on
the underlay to ensure successful channel assignment.
Preferentially assigns channels on the overlay when the uplink receive level on
the SDCCH is no smaller than "Assign-optimum-level Threshold" and the TA is
smaller than "TA Threshold of Assignment Pref"; otherwise, assigns channels on
the underlay to ensure successful channel assignment.
This parameter specifies the TRX priority in channel assignment. The smaller
this parameter is, the higher the TRX priority is. For two TRXs with other
conditions identical, channels on the TRX with higher priority are preferentially
assigned.
Optical interface standard

Type of the operation

The operation type can be "FORBID" or "RESTORE".

Iur-g signaling point index of an internal RNC in GU mode


If "Port Type" is set to "TOPEXTOUTPORT", this parameter determines the
extended E1/T1 port through which the timeslots on the source E1/T1 port are
used by other boards. If "Port Type" is set to "TOPEXTINPORT", this parameter
is set 255.
Operation type of the command.
Ordinary frequency. Multiple frequencies are separated by "&". For example,
"22&33&44&55" are allocated to TRXs in ascending order.
This parameter indicates the total number of hardware modules, excluding
those of GSM.
One of the parameters that decide the underlay and overlay areas in an
enhanced IUO cell. The underlay and overlay areas are decided by "OtoU HO
Received Level Threshold", "UtoO HO Received Level Threshold", "RX_QUAL
Threshold", "TA Threshold", and "TA Hysteresis" together.
Whether to assign channel requests initiated in the underlay subcell to the
overlay or underlay subcells according to "UL Subcell General Overload
Threshold". If the load of the underlay is higher than "UL Subcell General
Overload Threshold", incoming calls in the underlay subcell will be
preferentially assigned to the overlay subcell.
The timer is used to set the time when the BSC6900 waits for a handover
success message after a handover command is sent in an outgoing BSC
handover. If the timer expires, the outgoing BSC handover fails.
The timer is used to set the time when the BSC6900 waits for an HO REQ ACK
message after a Handover Request message is reported in an outgoing BSC
handover. If the timer expires, the outgoing BSC handover fails.
Whether to use external 2G neighboring cells as the target cells of load
handovers

When the load of the underlay subcell is higher than this parameter, some of
the calls in the underlay subcell will be switched to the overlay subcell, and
channels in the overlay subcell will be preferentially assigned to calls initiated
in the underlay subcell as well.

Power overload threshold for triggering outgoing handover from the TRX under
the prerequisite that the power amplifier of the TRX provides the maximum
output power. If the power overload exceeds this threshold, the TRX triggers
outgoing handover for lack of power.
Lower threshold of the overlay level during overlay-to-underlay handovers.
When the receive level of an MS is higher than this threshold, the MS can be
switched to the underlay subcell.

Whether to switch some of the calls in the underlay subcell to the overlay when
the load of the underlay is higher than this parameter

If the underlay load is higher than "UL Subcell Serious Overload Threshold", the
underlay-to-overlay handover period subtracts a value that equals this
threshold from "UL Subcell Load Hierarchical HO Periods" every second.

When the load of the underlay subcell exceeds "UL Subcell General Overload
Threshold", all the calls that are using this cell as the serving cell generate
handover requests at the same time, which will suddenly increase the load of
the BSC and possibly cause congestion in the overlay subcell, thus causing the
handovers to fail. To solve this problem, the BSC uses the hierarchical load
handover algorithm to gradually switch some of the calls in the underlay
subcell to the overlay subcell. This parameter indicates the duration of each
handover level.

Level step during underlay-to-overlay hierarchical load handovers

When the load of the underlay subcell is lower than this parameter, some of the
calls in the overlay subcell will be switched to the underlay subcell, and
channels in the underlay subcell will be preferentially assigned to channel
requests initiated in the overlay subcell as well.

Specifies the timeslot mask out BSC6900

Outgoing BSC6900 port number


Number of the outgoing port of the DXX

Number of the outgoing timeslot of the DXX


Level of the accessed alarm signal. If the alarm signal has high level, this
parameter should be set to 0. Otherwise, it should be set to 1.
Level of the accessed alarm signal. If the alarm signal has high level, this
parameter should be set to 0. Otherwise, it should be set to 1.
Level of the accessed alarm signal. If the alarm signal has high level, this
parameter should be set to 0. Otherwise, it should be set to 1.
Level of the accessed alarm signal. If the alarm signal has high level, this
parameter should be set to 0. Otherwise, it should be set to 1.
Output power of the location group. For a location group that consists of MRRU
or GRRU boards, the default output power is 15W. For a location group that
consists of DRRU boards, the default output power varies with frequency bands.
That is, when the frequency band is 850M/900M, the default output power is
18W; when the frequency band is 1800M/1900M, the default output power is
15W.
Output power of the location group

Output power unit of the location group

When the load of the underlay subcell is higher than this parameter, the
underlay-to-overlay load handover period subtracts a period that equals "Step
Length of UL Subcell Load HO" from "UL Subcell Load Hierarchical HO Periods"
every second, thus increasing the load handover speed.

Whether to report a cell out-of-service alarm after a cell is out of service

Slot number of the load outlet interface board


Outgoing BSC6900 slot number
Outgoing BSC6900 subrack number
This parameter specifies whether to allow the inter-RAT load handover in
connection mode (after the assignment is complete).
When the Service Handover field in an ASS REQ message is 0, a direct retry
process targeted at a 3G network is initiated. If the direct retry fails, the system
decides whether to re-assign channels for the current call based on this
parameter.
When this parameter is set to Open, the BSS decides whether to hand over the
current service to the 3G network according to the contents of the "Service
Handover" information element in the ASS REQ and HO REQ messages.
Validity period for the BSC to keep the load information about a 3G neighboring
cell on the RNC
Outgoing BSC6900 start timeslot number
Abnormally alarm raise threshold triggered by too heavy current of the ANT_A
tributary antenna. When the actual current is higher than the configured value,
the ALD Current Abnormally Alarm is triggered with the corresponding alarm
tributary No. of 0.
Abnormally alarm raise threshold triggered by too heavy current of the ANT_B
tributary antenna. When the actual current is higher than the configured value,
the ALD Current Abnormally Alarm is triggered with the corresponding alarm
tributary No. of 0.
Abnormally alarm raise threshold triggered by too heavy current of the RET
tributary antenna. When the actual current is higher than the configured value,
the ALD Current Abnormally Alarm is triggered with the corresponding alarm
tributary No. of 0.
Clearance threshold for the alarm triggered when the ANT_A tributary antenna
is over current. When the actual current is below this threshold, the ALD
Current Abnormal Alarm is cleared.

Abnormally alarm clearance threshold triggered by too heavy current of the


ANT_B tributary antenna. When the actual current is lower than the configured
value, the ALD Current Abnormally Alarm clearance is triggered with the
corresponding alarm tributary No. of 0.
Clearance threshold for the alarm triggered when the RET tributary antenna is
over current. When the actual current is below this threshold, the ALD Current
Abnormally Alarm is cleared.
When the ANT_A tributary antenna current abnormally check mode is set to
Mode 3, the parameter ALD Current Prompt Alarm is checked by periodical
pulse. The periodical pulse consists of antenna over-current duration and
normal current duration. This parameter is the ANT_A tributary antenna overcurrent duration.
When the ANT_B tributary antenna current abnormally check mode is set to
Mode 3, the parameter ALD Current Prompt Alarm is checked by periodical
pulse. The periodical pulse consists of antenna over-current duration and
normal current duration. This parameter is the ANT_B tributary antenna overcurrent duration.

Interval for the BTS transmitting overload messages to the BSC6900. This
parameter is used to control the reporting frequency of overload messages by
the channel and TRX.
The overload can be the TRX processor overload, downlink CCCH overload, or
AGCH overload. For details, see GSM Rec. 08.58.

Temperature threshold of the derating function of the cabinet

Threshold for critical flow control. When the usage of the CPU exceeds the
threshold, the CPUS performs critical flow control for paging messages.
Threshold for major flow control. When the usage of the CPU exceeds the
threshold, the CPUS performs major flow control for paging messages.
Threshold for minor flow control. When the usage of the CPU exceeds the
threshold, the CPUS performs minor flow control for paging messages.

Threshold for slight flow control. When the usage of the CPU exceeds the
threshold, the CPUS performs slight flow control for paging messages.
This parameter specifies whether the multi-carrier transceiver unit supports the
Multi-Carrier Intelligent Voltage Regulation feature.
When this parameter is set to YES, the multi-carrier transceiver unit
automatically regulates its working voltage according to the power
requirements of a service. When this parameter is set to NO, the multi-carrier
transceiver unit works at a fixed working voltage.This parameter applies only to
BTS3036, BTS3036A, DBS3036, BTS3900 GSM, BTS3900L GSM, BTS3900A GSM,
DBS3900 GSM, BTS3900E base stations. For other base stations, this parameter
is not displayed and cannot be configured (the fixed value is Null).

Whether to support the function of moving the packet assignment down to the
BTS. To improve the access speed of the MS, after the packet assignment is
moved down to the BTS, the BSC reserves the uplink resources for the BTS. The
BTS obtains the channel request of the MB by analyzing the downlink
acknowledgement message sent by the MS. Then the BTS allocates the
reserved uplink resources to the MS to move the packet assignment to the BTS.

Average number of paging messages allowed in a cell in a period

Lifetime of a paging message in the queue of the BTS. The setting of this
parameter must be consistent with the setting of timer T3113 in the core
network; otherwise, the efficiency of paging scheduling over the Um interface is
reduced. It is recommended that this parameter be set to a value one to two
seconds shorter than timer T3113. The units of this parameter is 250ms.

Maximum number of paging messages allowed in a cell in a period

For the BTS, this parameter is used to determine paging retransmissions. This
parameter and the number of paging times configured in the MSC determine
the number of paging retransmissions. The total number of paging times is
approximately equal to the value of this parameter multiplied by the number of
paging times configured in the MSC.
This parameter sets the PAN_DEC value used by the counter N3102 of the MS.
When the timer T3182 of the MS expires, the N3102 reduces the value of
PAN_DEC. 0: the value of PAN_DEC is 0; 7: the value of PAN_DEC is 7; Value N
indicates that PAN_DEC is N; Not use: this parameter is not used.

This parameter sets the PAN_INC value used by the counter N3102 of the MS.
When receiving the packet uplink acknowledged or unacknowledged message
sent by the network (V(S) or V(A) increases), the MS increases the count
(PAN_INC) of the counter N3102. 0: the value of PAN_INC is 0; 7: the value of
PAN_INC is 7; Value N indicates that PAN_DEC is N; Not use: this parameter is
not used.
RAN_MAX value, the maximum value of the N3102. 4: the value of PAN_MAX is
4; 32: the value of PAN_MAX is 32. Value N indicates that PAN_DEC is N; Not
use: this parameter is not used.

Priority level at which the BSC shuts down the power amplifier of the TRX when
the intelligent shutdown function is enabled. If this parameter is set smaller,
the priority level is higher, the power amplifier of the TRX is shut down later.

Patch number of the TMU board software

Patch number of the TMU board software


IP path check flag

Uniquely identifies an IP path

IP path ID,Identifying an IP path.

Transmission loss difference between radio frequencies on different bands

Whether to perform path loss-based sorting in a better cell handover algorithm

Type of the IP path

Patch type

BTS power attenuation on the measured PBCCH

Whether to use the PBGT handover algorithm. PBGT handovers are based on
path loss. The PBGT handover algorithm searches in real time for cells that
have lower path loss and meet certain system requirements, and decides
whether to perform the handovers. To avoid ping-pong handovers, PBGT
handovers can occur only on TCHs and among cells on a same layer and a
same priority level.

The triggering of PBGT handovers must meet the P/N criteria, that is, when the
condition for PBGT handovers is met for a consecutive P seconds during N
seconds, a PBGT handover is triggered. This parameter corresponds to the P in
the P/N criteria.

PBGT handovers to a neighboring cell are allowed only when the downlink level
difference between the neighboring cell and the serving cell is larger than this
parameter. When the value of this parameter is smaller than 64, handovers to a
neighboring cell with a lower level than the current serving cell are allowed.

The triggering of PBGT handovers must meet the P/N criteria, that is, when the
condition for PBGT handovers is met for a consecutive P seconds during N
seconds, a PBGT handover is triggered. This parameter corresponds to the N in
the P/N criteria.

Maximum times for an external PCU to retransmit a PB interface maintenance


message. When the PCU fails to receive a response to a PB interface
maintenance message before the timer timeouts, it retransmits the PB
interface maintenance message to the BSC.

Minimum interval between two consecutive power control commands

Channel used for the measured receiving power. It is used to set the measured
receiving power level of the channel and control the power of the uplink.
It is one key filed of identifying Pb interface CIC status and indicates the PCU
No. corresponding to the Pb interface CIC.

PCU number, identifying a unique PCU.


Number of the PCU to which the current cell belongs
Port number of the E1/T1 of the Pb interface
Whether the PCU supports the PREEMPT_ABIS_LINK message. If the BTS
supports the FLEXABIS function, the CS service can preempt the timeslots on
the Abis interface used by the PS service. After the preemption occurs, the
BSC6900 sends a PREEMPT_ABIS_LINK message to the PCU if the PCU can
process the message.

PDCH downlink multiplex threshold, Indicating the maximum TBFs on the


downlink PDCH (parameter value/10).We recommand that the value of
"Downlink Multiplex Threshold of Dynamic Channel Conversion" should be less
than "PDCH Downlink Multiplex Threshold" for triggering converting dynamic
channel in time and reducing PDCH multiplex.

This parameter specifies whether to enable the Power Optimization Based on


Channel Type feature. The working voltage of the TRX varies with the
modulation mode of the channel. When this parameter is set to YES, the TRX
adopts the working voltage according to the modulation mode of the dynamic
PDCH.
This parameter must be used together with "Level of Preempting Dynamic
Channel" in the following conditions:
1. When "Level of Preempting Dynamic Channel" is set to "No preempt of
service TCHF" and "PDCH Reforming" is set to "Yes", the channels for the CS
service is released if the CS service fails to be switched to another channel.
2: When "Level of Preempting Dynamic Channel" is set to "Preempt all dynamic
TCHFs" or "No preempt of CCHs" and "PDCH Reforming" is set to "Yes", the CS
service is switched to the original channel if the CS service fails to be switched
to another channel.

PDCH uplink multiplex threshold, indicating the maximum TBFs on the uplink
PDCH (parameter value/10). We recommand that the value of "Uplink Multiplex
Threshold of Dynamic Channel Conversion" should be less than "PDCH Uplink
Multiplex Threshold" for triggering converting dynamic channel in time and
reducing PDCH multiplex.

Pending timer of the M3UA link set

ID of the peer BSC6900

Peer BSC ID. It identifies a BSC.

IP address of the peer BSC6900 on the homing BSC6900 side

Subnet mask of the port IP address at the peer BSC6900.

Identifier of the peer BTS on the homing BSC6900 side

IP address of the peer end of BTS PPP Link.

IP address of the peer end of BTS MLPPP Group.


Peer IP address of the PPP link. The IP address of the PPP link on the peer side
of the BSC.
Peer IP address of the MP group.
Detects the IP address of the gateway

First destination IP address. The invalid value is 0.

Second destination IP address. The invalid value is 0.

The peer IP address should not be the same as the local address.

Subnet mask of the peer IP

Destination SCTP port number

Peer Software Version

Whether to punish the target cell when a handover fails or to punish the current
serving cell when a handover is of more TA or bad quality.
After a handover fails due to congestion of the target cell, the system needs to
punish the target cell to prevent the MS from attempting to switch to the target
cell again.
Ping-pong handovers can easily occur when handovers are of more TA or bad
quality. In these cases, the system needs to punish the current serving cells.

Penalty duration for cell reselection. Cell penalty can be performed only in this
duration. When this parameter is set to a greater value, the MS cannot reselect
a cell for a longer time in the case of reselection failure or reselection due to
load. The penalty timer is shorter when this parameter is set to a smaller value.

When the cell reselection failure message is received or the load cell
reselection is initiated, the "Cell Penalty Level" is subtracted from the receive
level of the target cell to avoid that cell reselection failure occurs repeatedly or
that multiple MSs are reselected to the same target cell. This parameter is valid
only within "Cell Penalty Duration".

Timer of penalty on a neighboring cell when a handover fails due to faults of


data configuration.

Measurement period for each frequency group

Ping check period of IP Path

Whether to compress the protocol field of the PPP link.

Compression flag of the PPP link protocol domain

Compression flag of the PPP link protocol domain

Whether to support packet flow context (PFC). The PFC flow is used to control
the QoS of the packet service of the MS.

Whether to support the paging message classification function:


0,close;
1,paging message classification flow control;
2,re-paging flow control.

Maximum number of paging messages that the BSC6900 can process over the
A interface within a measurement period

Maximum number of PS paging messages that the BSC6900 can process within
a "Paging Statistical Period".

Measurement period for calculating the arrival rate of paging messages

PHB type of the IPMUX to be enabled

Value of the per-hop behavior (PHB)

Cell Reselect Parameters Indication (PI), sent on the broadcast channel,


indicates whether "Cell Reselect Offset", "Cell Reselect Temporary Offset" in the
"SET GCELLIDLEAD" command, and "Cell Reselect Penalty Time" are used.

Whether to enable the private key password


DISABLE: indicating that the private key password is disabled
ENABLE: indicating that the private key password is enabled

Indicates the number of the packets for remote loopback test of the OAM in the
Ethernet

Indicates the length of the packets for the remote loopback test of the OAM in
the Ethernet

Loopback packet length

Maximum multiplexing frame length. The length of the multiplexed packet must
not exceed the maximum multiplexing frame length. If the length of the
multiplexed packet exceeds the maximum multiplexing frame length, the
packet is transferred without being added with new subframes. The frame
length refers to the payload, excluding the IP/UDP header.
Whether the cell supports the PACKET SI STATUS flow. In the PACKET SI STATUS
flow, the MS sends the Packet PSI/SI Status message to indicate that the MS has
stored the system message. The network side sends the Packet Serving Cell
Data message to notify the MS of the system message not stored.

Sent packet size


Indicates the size of the PING packet, neither IP header nor ICMP header is
included.
Persistence level 1 of the radio access priority.
During MS access, the access priority of the MS is set. If the priority of the MS is
higher than the access priority of the MS, the cell allows the access of the MS.
Otherwise, the cell rejects the access of the MS. The value "no use" indicates
this parameter is not used.
Power attenuation level of all the other timeslots of the BCCH except for
timeslot 7 in 16QAM. The attenuation level ranges from 0 to 50, with the step of
0.2 dB. When the EDGE TRX sends signals in 16QAM, the transmit power must
be lower than the mean power in GMSK.
Persistence level 2 of the radio access priority.
During MS access, the access priority of the MS is set. If the priority of the MS is
higher than the access priority of the MS, the cell allows the access of the MS.
Otherwise, the cell rejects the access of the MS. The value "no use" indicates
this parameter is not used.
Persistence level 3 of the radio access priority.
During MS access, the access priority of the MS is set. If the priority of the MS is
higher than the access priority of the MS, the cell allows the access of the MS.
Otherwise, the cell rejects the access of the MS. The value "no use" indicates
this parameter is not used.
Power attenuation level of all the other timeslots of the BCCH except for
timeslot 7 in 32QAM. The attenuation level ranges from 0 to 50, with the step of
0.2 dB. When the EDGE TRX sends signals in 32QAM, the transmit power must
be lower than the mean power in GMSK.

Persistence level 4 of the radio access priority.


During MS access, the access priority of the MS is set. If the priority of the MS is
higher than the access priority of the MS, the cell allows the access of the MS.
Otherwise, the cell rejects the access of the MS. The value "no use" indicates
this parameter is not used.
Power attenuation level of the EDGE TRX. There are 50 power attenuation
levels. At each level, the power is attenuated by 0.2 dB. The spectrum
requirements are met only when the power of an EDGE transceiver for
transmitting 8PSK signals is lower than the average power for GMSK
modulation.
Statistics period of the packet drop ratio. This parameter indicates the period
for collecting the statistics information about the packet drop ratio. Note that
the unit of this parameter is 100 milliseconds. The actual delay statistics period
is the value of this parameter multiplied by 100 milliseconds.
Packet drop ratio threshold for speed reduction. When the packet drop ratio
exceeds the value of this parameter, the rate of the logical port is reduced.
Note that the unit of this parameter is a thousand to one.
Point at which to play sound

Whether to enable sound playing


Duration of sound playing. If this parameter is set to 0, the sound is played
repeatedly. If this parameter exceeds the duration of the record file, the void
sound is played for the exceeding part.
CPU usage threshold for performance monitoring. When the average CPU usage
of sliding windows reaches or exceeds the threshold, performance monitoring is
triggered.
Packet queue usage threshold for performance monitoring. When the average
packet queue usage of sliding windows reaches or exceeds the threshold,
performance monitoring is triggered.
Interval for sending cell paging group packets when Paging Messages Optimize
at Abis Interface is enabled
Number of cell paging group packets when Paging Messages Optimize at Abis
Interface is enabled
Whether to enable Paging Messages Optimize at Abis Interface. The BSC6900
combines multiple paging messages to a cell paging package and then sends
the package to the BTS. The package reduces header overhead and thus
reducing the load on the Abis link.

CPU usage threshold for recovery from performance monitoring. When the
average CPU usage of sliding windows is lower than the threshold, performance
monitoring is stopped.
Packet queue usage threshold for recovery from performance monitoring. When
the packet queue usage of sliding windows is lower than the threshold,
performance monitoring is stopped.
Whether to monitor the RRM performance
Port number
Number of the E1/T1 port on the Ater interface board. E1 mode: 0~31 (EIU),
0~62(OIU), 0~251(POUc). T1 mode: 0~31(EIU), 0~83(OIU), 0~335(POUc).
Port number

Number of the port


Port No. of the XPU board. If you do not specify this parameter, all ports of the
XPU board are queried.
Port No. of environment alarm
Number of the port where the alarm is generated, only the ports for data
transmission are supported, such as E1/T1 port, channelized optical port
tributary, optical port, and Ethernet port

Alarm port number

Port number

Ethernet port

It is one key field of identifying the block of the Ater timeslot and indicates the
port No. of the Ater interface timeslot.

Indicates the port number for running this command.

E1/T1 port number

E1/T1 port number

E1/T1 port number

Indicates the port number for running this command.

Port number
Port number

Ethernet port

FE/GE port number


Port number
E1/T1 port number

Port number of the E1/T1 of the Pb interface


Port number of Pb signaling link

Port No. of the BSC6900 board connected with the BTS

Number of the port on the BTS side

Number of the port on the BTS side

Number of the port through which the BTS is connected to the BSC6900

Number of the FE or GE port

Number of the Ethernet port. The number must be consistent with that of the
port carrying the FE connection of the IP BTS.
Port number

Maximum transmission delay of the POC service (push to talk over cellular).
The transmission delay of the POC service must be relatively small. The
network side must support the function of detecting the POC service type and
reduce the delay through related processing to meet the POC service
requirement. For the POC service received by the network side, Transfer Delay
in the ABQP must be lower than the transmission threshold of the POC service.

Maximum bandwidth of the POC service (push to talk over cellular). The
transmission delay of the POC service must be relatively small. The network
side must support the function of detecting the POC service type and reduce
the delay through related processing to meet the POC service requirement. For
the POC service received by the network side, GbrValue in the ABQP must be
lower than the maximum bandwidth of the POC service.

Minimum bandwidth of the POC service (push to talk over cellular). The
transmission delay of the POC service must be relatively small. The network
side must support the function of detecting the POC service type and reduce
the delay through related processing to meet the POC service requirement. For
the POC service received by the network side, GbrValue in the ABQP must be
larger than the minimum bandwidth of the POC service.

Whether to support the push to talk over cellular (POC) service

This parameter specifies a condition for generating a BTS alarm. When the
output power of a TRX of a transmitter is lower than a fixed level, an error is
generated. This parameter and "Power output error threshold" indicate the two
thresholds of the error. If this parameter is set to a large value, the error is
small. The value range is 0 to 9, indicating -10 dB to -1 dB.
This parameter specifies a condition for generating a BTS alarm. When the
output power of a TRX of a transmitter is lower than a fixed level, an error is
generated. This parameter and "Power output reduction threshold" indicate the
two thresholds of the error. If this parameter is set to a large value, the error is
small. The value range is 0 to 9, indicating -10 dB to -1 dB.

Description of the rollback point

Name of the rollback point

This port is provided by the FTP server to be visited by the FTP client.
Number of the port where to set up the link after the main and backup OMLs of
the BTS are swapped

Number of the port where to set up the link after the BTS ring is swapped. If
this parameter is set to 0, the BTS works on a forward ring. If this parameter is
set to 1, the BTS works on a backward ring.
Number of the DXX port

Maximum number of ports on the DXX

Port protocol type

Whether to enable the panel port of the XPU board


Indicates the type of the physical port used by the local maintenance point in
the maintenance group. FE indicates the FE port and TRUNK indicates the
aggregation group.
Type of the port. If this parameter is set to "TOPEXTOUTPORT", the local E1/T1
ports are used to extend the transmission of other boards. That is, the timeslots
on the source E1/T1 port are used by other boards through the extended E1/T1
port. If this parameter is set to "TOPEXTINPORT", the local E1/T1 ports are used
to extend the transmission of local boards. That is, the local boards can obtain
the timeslots from other boards through the extended E1/T1 port.

Whether to transmit the 2Quater message on the BCCH Norm channel or the
BCCH Ext channel

Type of the patch operation

Rated maximum output power of the diesel engine. Refer to the rated output
power described on the diesel engine label.
Relay switch 1

Relay switch 2

Relay switch 3

Relay switch 4

Relay switch 5

Relay switch 6

Battery current shunt coefficient


Power attenuation level of timeslot 7 of the BCCH in 16QAM. The attenuation
level ranges from 0 to 50, with the step of 0.2 dB. When the EDGE TRX sends
signals in 16QAM, the transmit power must be lower than the mean power in
GMSK.
Power attenuation level of timeslot 7 of the BCCH in 32QAM. The attenuation
level ranges from 0 to 50, with the step of 0.2 dB. When the EDGE TRX sends
signals in 32QAM, the transmit power must be lower than the mean power in
GMSK.
Power type managed by the PMU

Type of the power supply system of the cabinet

This parameter specifies the transmit power level of the TRX. The greater this
parameter is, the smaller the transmit power is. When this parameter is set to
"0", the transmit power level of the TRX is the greatest. Each time this
parameter increases by one level, the transmit power reduces by 2 dB.
For different types of BTSs, the value range of this parameter is different.
BTS3X: 0-10
BTS3001C: 0-13
BTS3002C: 0-10
Double-transceiver BTSs (BTS3012,BTS3012AE,BTS3006C): 0-10
DBS3900 GSM, BTS3900 GSM, BTS3900A GSM: 0-10.

This parameter specifies the maximum transmit power supported by the power
amplifier of the TRX. The macro BTS and the mini BTS support different power
levels.

When the number of error frames on the PPP layer reaches the value of this
parameter, the frame error alarm is generated.

When the number of error frames on the PPP layer decreases to the value of
this parameter, the frame error alarm is cleared.

Number of a BTS PPP link.

PPP link number of BSC.


PPP link number

PPP link number


Whether to enable the PPP frame multiplexing function. If this parameter is set
to ENABLE, the PPP frame multiplexing function is enabled. If this parameter is
set to DISABLE, the PPP frame multiplexing function is disabled.

This parameter applies to the FG2a and GOUa boards. For the FG2c, GOUc, or
POUc board, this parameter is always set to 2.

This parameter specifies whether the preempted call is released after the
handover failure. If this parameter is set to No, MSs with high priorities can
access the network preferentially, but the preempted call drops; if this
parameter is set to Yes, the preempted call is not released. In this case, the
access requests from MSs with high priorities initiate the queuing procedure or
the calls fail. Therefore, the access rate of MS with high priorities is decreased.
This parameter specifies whether to preempt PDCHs when no TCH is available
during the handover of the preempted call. When this parameter is set to Yes,
the call drop rate of the preempted call is decreased, but the rate of PS services
is affected.
If this parameter is set to ON, the BSC initiates a TCHF preemption when
receiving a link establishment indication from an MS in an emergency call.
Sampling rate of pre-processed measurement reports.
Priority of a route. A smaller value of this parameter indicates a higher priority.
The BTS preferentially selects the route with a high priority to transfer
information.
Access priority of the MS that is allowed to access the cell. The MS sends the
packet channel request containing the 2-bit radio priority message. The priority
of the 2-bit radio priority message ranges from 1 to 4 in descending order.
During the MS access, the BSC compares the radio priority in the channel
request with the parameter setting of the cell. If the radio priority equals to the
parameter setting of the cell, the BSC sets up the TBF for the channel request.
This parameter specifies whether to support flow control based on priority.
When this parameter is set to on, the system preferentially admits the calls
initiated by VIP users.

Whether the BTSs send the original measurement reports to the BSC after preprocessing them. When this parameter is set to YES, the BTSs sends the
original and pre-processed measurement reports to the BSC.

Printing control threshold. If the CPU usage of sliding windows reaches or


exceeds the threshold, printing flow control is triggered on the serial port.
Printing control threshold. When the packet queue usage of sliding windows
reaches or exceeds the threshold, printing flow control is triggered on the serial
port.

Printing control threshold. If the CPU usage of sliding windows is lower than the
threshold, printing flow control on the serial port is stopped.
Printing control threshold. When the packet queue usage of sliding windows is
lower than the threshold, printing flow control on the serial port is stopped.
Whether to control the printing flow on the serial port

This parameter controls handover between cells at the same layer. Generally,
the cells at the same layer are set with the same priority. If the cells at the
same layer have different priorities, a cell with a smaller priority value has a
higher priority.

This parameter controls the handovers among cells on a same layer. A smaller
priority value indicates a higher priority. Cells with higher priorities are
preferentially selected as the handover target cells.
If the static Abis resource load is greater than the value of "Fix Abis Prior
Choose Abis Load Thred" and the dynamic Abis resource load is greater than
the value of this parameter, the half-rate channel is preferred. Otherwise, the
full-rate channel is preferred.
Priority of the hierarchical cell structure (HCS).
0: indicates the lowest priority;
7: indicates the highest priority.
Route priority. The highest priority is represented by 0.
Priority of the signaling link. 0 indicates the highest priority. A low-priority link
carries services only when the high-priority link is faulty.
Route priority. The boards FG2a, GOUa, UOIa(IP), FG2c, and GOUc support the
configuration of routes with different priorities. Suppose two or more routes are
configured and their addresses and masks are the same, and the addresses of
the next hops and priorities. These routes can be configured in the active and
standby mode. When the route with higher priority is available and only this
route is valid, the system switches to the route with lower priority once the
route with higher priority fails.

Preferential customized detection type when the customized sequence is used


for port detection.
Number of customized detection types involved when the customized sequence
is used for port detection.
Subsidiary customized detection type when the customized sequence is used
for port detection. This parameter is valid only when Number of Customized
Detection Types is set to 2.
Name of the private key file

Port detection sequence used during BTS startup.


Identifies the DSP protocol type, including ITUT(International
Telecommunication Union - Telecommunication Standardization Sector),
ANSI(American National Standards Institute), and TTC(Telecommunication
Technology Committee (Japan)).

Protocol type of the trunk frame. The setting of this parameter must be
consistent with the setting at the SGSN side.

The transmission resource in the Abis timeslot is considered as faulty only when
the BTS detects that the Abis timeslot is faulty in the delay. The transmission
resource in the Abis timeslot is considered as normal when the BTS detects the
Abis timeslot is normal.
This parameter specifies a period of time during which a cell cannot be enabled
or disabled to prevent frequent cell enabling or disabling operations. That is,
after a cell is enabled, it cannot be disabled within the period of time specified
by this parameter; after a cell is disabled, it cannot be enabled within the
period of time specified by this parameter.
This parameter is set to prevent the BSC from frequently enabling or disabling
the TRX. After a TRX is powered on, the BSC is not allowed to disable the TRX
within the period of time specified by this parameter.
Port selection
Port selection

Port selection
This parameter indicates whether to include Abis interface messages in PS CHR
logs.

This parameter indicates whether to include Gb interface messages in PS CHR


logs.

This parameter indicates whether to include internal information in PS CHR


logs. The internal information is the basic user information, including user type,
MS mulitple timeslot capability, cause for TBF abnormal release, and service
type.
This parameter indicates whether to include internal messages in PS CHR logs.
The messages are generated in service data flow and transmitted between
internal moudles, including uplink/downlink resource request, uplink/downlink
resource indication, uplink/downlink resource rejection, TS indication, TS
rejection, and PDU removal indication.
This parameter indicates whether to include Um interface messages in PS CHR
logs.

GSM PS data service downlink factor

GSM PS data service uplink factor

Whether to support PS Handover(PS HO). The PS HO is used to reduce the


interval of the cell reselection of the MS.

PS high PRI data path

PS high PRI data priority

Priority for PS services over the Abis interface in IP, IP over E1, or HDLC mode
when PS preferred. When "Level of Preempting Dynamic Channel" is set to "No
preempt of service TCHF" through the "SET GCELLPSCHM" command, PS
services are assigned with a high priority. If "PS High PRI Service PRI" is set to a
great value, the priority for PS services becomes low.
Period for sending the packet message PSI. If the period is too long, the
message PSI cannot be obtained in realtime. If the period is too short, the
message PSI is broadcast frequently, which occupies too much system
resources.
Whether the BSC supports the state message PSI. The state message PSI refers
to PSI STATUS.

PS low PRI data path

PS low PRI data priority

Priority for PS services over the Abis interface in IP, IP over E1, or HDLC mode
when CS preferred. When "Level of Preempting Dynamic Channel" is set to
"Preempt all dynamic TCHFs" or "No preempt of CCHs" through the "SET
GCELLPSCHM" command, CS services are assigned with a high priority. If "PS
Low PRI Service PRI" is set to a great value, the priority for PS services becomes
low.
Threshold of the receive level for triggering the handover of the PS services
from the overlaid subcell to the underlaid subcell
This parameter indicates the mode of exporting PS CHR logs. When the
parameter is set to &quot;Common User Mode&quot;, the PS CHR logs of a
specified cell are exported (the command is "SET GPSCHRSCOPE"); when the
parameter is set to &quot;Specified User Mode&quot;, the PS CHR logs of a
specified MS are exported (the command is "ADD GPSCHRUSER"). The two
modes can coexist without affecting each other.

This parameter specifies the level threshold for the random access of the MS. If
the receive level of the RACH burst in the PS domain is smaller than the value
of PS RACH Min.Access Level, the BTS regards this access as an invalid one and
no decoding is performed. If the receive level of the RACH burst is greater than
the value of PS RACH Min. Access Level, the BTS considers that an access
request exists on this timeslot, and determines together with the value of
"Random Access Error Threshold" whether the RACH access is valid.

Minimum voltage level for accessing PS services of the location group

This parameter indicates whether to record PS CHR logs.


Maximum number of messages in the statistical period for the arrival of PS
resource requests
Statistical period for the arrival of PS resource requests
Whether to enable the DPSU0 to supply power for the BTS.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to enable the DPSU1 to supply power for the BTS.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Whether to enable the DPSU2 to supply power for the BTS.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Whether to enable the DPSU2 to supply power for the BTS.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to enable the DPSU3 to supply power for the BTS.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Whether to enable the DPSU4 to supply power for the BTS.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to enable the DPSU5 to supply power for the BTS.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to enable the DPSU6 to supply power for the BTS.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to enable the DPSU7 to supply power for the BTS.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Threshold of the receive level for triggering the handover of the PS services
from the underlaid subcell to the overlaid subcell
This parameter specifies whether the BTS is allowed to enable the PSU Smart
Control feature.
When this parameter is set to YES, the BTS automatically enables or disables
the PSU according to the traffic volume to improve the efficiency of the PSU.
When this parameter is set to NO, the PSUs of the BTS are all working.
The following types of BTS support the PSU Smart Control feature:
BTS3012AE
BTS3900A, BTS3900, DBS3900, and BTS3900L: support the PSU Smart Control
feature through the matching APM30.

Switch for the self-healing of the OMU processes


Cell Reselect Penalty Time (PT) is used to ensure the safety and validity of cell
reselection because it helps to avoid frequent cell reselection. For details, see
GSM Rec. 05.08 and 04.08.
Port type of environment alarm

Alarm port type


Subnet protocol type

Number of the port that provides the time information on the SNTP server

Line coding method

Receiving frame structure

Sending frame structure

Frame structure

Number of a BTS HDLC path. It is unique in one [BTS].

Ethernet port type

Power system type. When the PMU is installed on the rack, you can select the
custom power system type.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Name of the certificate file

This parameter specifies the patch version loaded to the BTS.


This parameter can be set to only a hot patch version. You can use either of the
following methods to query the version number of the BTS hot patch.
Method 1: If the BTS hot patch is downloaded to the OMU through the MML
command DLD BTSPATCH, you can run the MML command LST BTSPATCH to
obtain the number of the hot patch package and the hot patch version
according to the returned result.
Method 2: If the BTS hot patch is not downloaded to the OMU, you can
decompress the BTS hot patch package. Then, check the patchcfg.xml file in
the level-1 directory of the compressed package. The value after the label
"PatchVersion" is the software version.

Number of the patch version

Period timer of PVC utilization report. This timer is started during initialization.
When the timer expires, the PVC utilization information is reported.
Password

User password for the FTP server. When the FTPServer.exe file downloaded
through the LMT is installed, the user password is admin.

Private key password

Minimum length of the user password

Power level

First alarm switch of power distribution monitoring board

Second alarm switch of power distribution monitoring board

Whether to allow active power control. If this parameter is set to YES, the
system performs power forecast in the process of initial access assignment or
service channel activation during intra-BSC handovers, and sends the forecast
initial power information to the BTSs through channel activation messages. In
this way, the MSs and BTSs can adjust the transmit power. If this parameter is
set to NO, the system does not perform power forecast, and the MSs and BTSs
choose the maximum transmit power.

Whether to enable the optimized power control algorithm III

Whether to enable power control algorithm II or power control algorithm III


If a class 3 MS on the DCS1800 band does not receive the original power
command after random access, the power that the MS uses is the MS maximum
transmit power level plus the power calculated from the power deviation. For
details, see GSM Rec. 05.08.
The MS does not receive the original power command after random access.
This parameter indicates whether the power deviation is added to the class 3
MS on the DCS1800 band on the basis of the maximum MS transmit power.
Whether to enable the power amplifier for all location groups. 0x01 indicates
that the TRX power amplifier is enabled for all location groups. 0x00 indicates
that the TRX power amplifier is enabled for the current location group.

Power mode.

Time interval between the time when the BTS detects that the external power
supply is shut down and the time when the backup power decrease function is
started. This parameter is valid in the BTSs that supports the backup power
decrease function.
When this parameter is set to YES, The BSC6900 preferentially uses the TRX
with good power-saving performance according to the TRX power priority
reported by the BTS. Smaller priority value indicates better power saving
quality. If the priority is of a great value, the BTS closes TRXs late.

Finetune of the TRX power. During the static finetune of the TRX power, the BSC
adjusts the TRX power at a step of 0.2 dB. In some scenarios, the losses vary
depending on the tributaries where the power is combined, and the power
difference before and after the power output is not an integral multiple of 2 dB.
As a result, the cabinet-top output power cannot be adjusted at a step of 2 dB,
and the TRX output power cannot be consistent with the cabinet-top output
power. Therefore, this parameter provides a smaller step that can adjust the
cabinet-top output power.
When the ANT_A tributary antenna power switch is ON, it is allowed to
configure related parameters of the ANT_A tributary.
When the ANT_B tributary antenna power switch is ON, it is allowed to
configure related parameters of the ANT_B tributary.
When the RET tributary antenna power switch is ON, it is allowed to configure
related parameters of the RET tributary.
Minimum DSCP of queue 0. The IP packets with DSCP in a relation that "Min
DSCP of queue 0" <= DSCP <= 63 is added to queue 0.
Minimum DSCP of queue 1. The IP packets with DSCP in a relation that "Min
DSCP of queue 1" <= DSCP < "Min DSCP of queue 0" is added to queue 1.
Minimum DSCP of queue 2. The IP packets with DSCP in a relation that "Min
DSCP of queue 2" <= DSCP < "Min DSCP of queue 1" is added to queue 2.
Minimum DSCP of queue 3. The IP packets with DSCP in a relation that "Min
DSCP of queue 3" <= DSCP < "Min DSCP of queue 2" is added to queue 3.
Minimum DSCP of queue 4. The IP packets with DSCP in a relation that "Min
DSCP of queue 4" <= DSCP < "Min DSCP of queue 3" is added to queue 4. The
IP packets with DSCP in a relation that 0 <= DSCP < "Min DSCP of queue 4" is
added to queue 5.
This parameter specifies the threshold of the signal level for cell reselection in
connection mode before ""Qsearch C"" is obtained.
Whether to enable the fast moving micro-cell handover algorithm. The fast
moving micro-cell handover algorithm enables fast moving MSs to switch over
to macro-cells, thus reducing the handover times.

This parameter is used in the P/N criteria decision: If an MS quickly passes


through N out of P micro-cells lately, the BSC enables the fast moving micro-cell
handover algorithm. This parameter corresponds to the N in the P/N criteria.

A time threshold determined based on the radius of a cell and the moving
speed of an MS. If the MS crosses the cell in a time period shorter than this
threshold, the BSC concludes that the MS quickly passes through the cell.
Otherwise, it concludes that the MS slowly passes the cell.

This parameter is used in the P/N criteria decision: If an MS quickly passes


through N out of P micro-cells lately, the BSC enables the fast moving micro-cell
handover algorithm. This parameter corresponds to the P in the P/N criteria.

This parameter specifies the level threshold for cell reselection in idle mode.
In idle mode,
if the signal level of the serving cell is below [0, 7] or above [8, 15], the MS
starts to search for 3G cells. For example, if this parameter is set to 5 and if the
signal level of the serving cell is lower than 5, the MS starts to search for 3G
cells; if this parameter is set to 10 and if the signal level of the serving cell is
above 10, then the MS starts to search for 3G cells.
The values of this parameter
correspond to the following decibel values:
0: -98 dBm
1: -94 dBm
2: -90 dBm
3: -86 dBm
4:
-82 dBm
5: -78 dBm
6: -74 dBm
7: (always), that is, the MS keeps searching for 3G cells
8: -78 dBm
9: -74 dBm
10: -70 dBm
11: -66 dBm
12: -62 dBm
13: -58 dBm
14: -54 dBm
15: Positive infinity(never), that is, the MS does not search for 3G cells

For the purpose of accurately reflecting the radio environment of a network,


filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of measurement
reports used for the filtering of the signal quality on service or data channels.
This parameter is used to determine whether interferences exist on channels.
For the purpose of accurately reflecting the radio environment of a network,
filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of measurement
reports used for the filtering of the signal quality on signaling channels. This
parameter is used to determine whether interferences exist on channels.

Whether to support QoC optimization. The GSN equipment for the GPRS
provides flexible QoS mechanisms for different subscribers. The QoS level is
also set during subscription. The QoS control parameters include: service
priority, reliability level, delay level, and data throughput level. During QoS
negotiation, the MS can apply for one value for each QoS attribute. When
receiving the request from the MS, the network must allocate a QoS level to
each attribute for each QoS document. The network provides related resources
for the negotiated QoS document.
This parameter specifies one threshold of the signal level for cell reselection in
packet transfer mode.
In packet transfer mode, if the signal level of the
serving cell is below [0, 7] or above [8, 15], the MS starts to search for 3G
cells. For example, if this parameter is set to 5 and if the signal level of the
serving cell is lower than 5, the MS starts to search for 3G cells; if this
parameter is set to 10 and if the signal level of the serving cell is above 10,
then the MS starts to search for 3G cells.
The values of this parameter correspond to the
following decibel values:
0: -98 dBm
1: -94 dBm
...
6: -74 dBm
7: (always)
8: -78 dBm
9: -74 dBm
...
14: -54 dBm

In connection mode, if the signal level is below [0-7] or above [8-15], the MS
starts to search for 3G cells. For example, if this parameter is set to 5 and if the
signal level of the serving cell is lower than 5, the MS starts to search for 3G
cells; if this parameter is set to 10 and if the signal level of the serving cell is
above 10, then the MS starts to search for 3G cells.
0: -98 dBm
1: -94 dBm
...
6: -74 dBm
7: (always)
8: -78 dBm
9: -74 dBm
...
14: -54 dBm
15: Positive infinity (never)

This parameter is used to avoid allocating the calls whose signal strengths
differ greatly to the same timeslot.
The BSC measures the signal merge conditions on each timeslot every 0.5
seconds. If the difference between the highest signal strength and the lowest
signal strength on a timeslot is greater than the value of "UL Signal Strength
Difference Threshold", it regards it as a signal merge event.
If N signal merge events are consecutively detected among P times of
measurements, the forcible intra-cell handover is triggered to switch the call
with the highest signal strength to another timeslot in the cell.
Here, N indicates "UL Signal Strength Difference Detections", P indicates "UL
Signal Strength Difference Maintains".

The P/N criteria is used to determine low downlink power for multi-density
carriers. If the downlink power of a multi-density carrier remains low during a
consecutive P seconds out of N seconds, the downlink power of the multidensity carrier is considered low. This parameter corresponds to the P in the P/N
criteria.
The P/N criteria is used to determine low downlink power for multi-density
carriers. If the downlink power of a multi-density carrier remains low during a
consecutive P seconds out of N seconds, the downlink power of the multidensity carrier is considered low. This parameter corresponds to the N in the
P/N criteria.

Whether to use the statistical multiplexing algorithm for multi-density power

Maximum number of times that the BTS finds that the air conditioner needs to
be switched off. If the number of times that the BTS finds that the air
conditioner needs to be switched off in the "CHKOFFTIMES" checks reaches this
parameter, the BTS switches off the air conditioner.
Maximum number of times that the BTS finds that the air conditioner needs to
be switched on. If the number of times that the BTS finds that the air
conditioner needs to be switched on in the "CHKONTIMES" checks reaches this
parameter, the BTS switches on the air conditioner.

Step of downward power adjustment according to the quality of the received


signals

Whether to query the classmark of the call in an incoming BSC handover

Whether to allow the fast handover algorithm

Auxiliary devices of rack 0. This parameter contains eight bits.


The eight bits, from the most significant bit to the least significant bit, indicate
whether to install a voltage stabilizer, internal battery, transmission power
supply, temperature control unit, auxiliary device 5, auxiliary device 6, auxiliary
device 7, and auxiliary device 8. When a bit is set to 1, the relevant auxiliary
device is installed. When a bit is set to 0, the relevant auxiliary device is not
installed. For example, if this parameter is set to 10000000, rack 0 is
configured with an auxiliary voltage stabilizer.

Whether to configure a battery rack for rack 0

Capacity of the battery rack configured for rack 0

Ratio of the maximum charging current of the battery pack configured for rack
0 to the capacity of the battery pack. For example, assume that the battery
pack has a capacity of 200 AH. If this parameter is set to 0.15C, the maximum
charging current of the battery pack is 30 A (= 0.15 x 200).

Type of the battery rack configured for rack 0

Auxiliary devices of rack 1. This parameter contains eight bits.


The eight bits, from the most significant bit to the least significant bit, indicate
whether to install a voltage stabilizer, internal battery, transmission power
supply, temperature control unit, auxiliary device 5, auxiliary device 6, auxiliary
device 7, and auxiliary device 8. When a bit is set to 1, the relevant auxiliary
device is installed. When a bit is set to 0, the relevant auxiliary device is not
installed. For example, if this parameter is set to 10000000, rack 1 is
configured with an auxiliary voltage stabilizer.

Whether to configure a battery rack for rack 1

Capacity of the battery rack configured for rack 1

Ratio of the maximum charging current of the battery pack configured for rack
1 to the capacity of the battery pack. For example, assume that the battery
pack has a capacity of 200 AH. If this parameter is set to 0.15C, the maximum
charging current of the battery pack is 30 A (= 0.15 x 200).

Type of the battery rack configured for rack 1

Auxiliary devices of rack 2. This parameter contains eight bits.


The eight bits, from the most significant bit to the least significant bit, indicate
whether to install a voltage stabilizer, internal battery, transmission power
supply, temperature control unit, auxiliary device 5, auxiliary device 6, auxiliary
device 7, and auxiliary device 8. When a bit is set to 1, the relevant auxiliary
device is installed. When a bit is set to 0, the relevant auxiliary device is not
installed. For example, if this parameter is set to 10000000, rack 2 is
configured with an auxiliary voltage stabilizer.

Whether to configure a battery rack for rack 2

Capacity of the battery rack configured for rack 2

Ratio of the maximum charging current of the battery pack configured for rack
2 to the capacity of the battery pack. For example, assume that the battery
pack has a capacity of 200 AH. If this parameter is set to 0.15C, the maximum
charging current of the battery pack is 30 A (= 0.15 x 200).

Type of the battery rack configured for rack 2

Route area of the current cell

Route area of the current cell


The NS performs location management based on routing areas during GPRS
packet services. Each routing area has a routing area identifier, which is
broadcast as a system message.
The NS performs location management based on routing areas during GPRS
packet services. Each routing area has a routing area identifier.
Identifies the routing area of the current cell

Route area of the current cell

This parameter specifies the level threshold for the random access of the MS. If
the receive level of the RACH burst in the CS domain is smaller than the value
of CS RACH Min.Access Level, the BTS regards this access as an invalid one and
no decoding is performed. If the receive level of the RACH burst is greater than
the value of CS RACH Min. Access Level, the BTS considers that an access
request exists on this timeslot, and determines together with the value of
"Random Access Error Threshold" whether the RACH access is valid.

Level threshold of the MS random access for the BTS to determine the RACH
busy state. When the receive level of the random access burst timeslot is
greater than this threshold, the BTS considers that the timeslot is busy.

Number of RACH burst timeslots in a RACH load measurement.


The value of this parameter indicates the interval during which the BSC6900
determines whether an RACH timeslot is busy. For details, see GSM Rec. 08.58.

Minimum voltage level for accessing CS services of the location group

Routing area color code of the GPRS cell

Whether to allow the MS to access another cell

Correlation threshold of the training sequence for the random access.


As defined in the GSM recommendation, the system can determine whether the
received signals are random access signals of the MS and calculate the TA
value by checking the correlation of the 41-bit training sequence.
Random Access Error Threshold
Number of Correct Bits in the 41-Bit Training
Sequence
90-100
33
101-120
34
121-140
35
141-160
36
161-175
37
176-195
38
196-221
39
222-243
40
244-250
41
0-89 or 251-255
38.

Hysteresis of cell selection in different routing area. When a standby or ready


MS starts cell reselection, if the original cell and the target cell are in the
different routing area, the signal level of the neighboring cell must be greater
that of the current cell. Their difference must be larger than the specified
hysteresis. Otherwise the MS cannot start cell reselection. The larger the
hysteresis of GPRS cell selection, the harder to start cell reselection.

Port rate of the IP interface board

Switch for controlling the AMR rate. Value 0 indicates that C/I is used to control
the AMR rate. Value 1 indicates that BER is used to control the AMR rate.

This parameter specifies whether the RATSCCH function is enabled during the
call establishment procedure. RATSCCH is used to dynamically reconfigure the
rate set of AMR while on a call. This parameter maps the versions of base
stations.
Original measurement report sampling rate (for each call, one out of four
measurement reports is collected)

LASTRBP indicates the last rollback point. The system automatically takes the
position where the current configuration command is executed as the rollback
point, and the user does not need to specify a rollback point. APPOINTRBP
indicates the rollback point specified by the user.

Type of recording the execution result


1. REC_ALL: indicating that the execution results of all the commands are
recorded no matter whether the commands are executed successfully.
2. REC_ERR: indicating that only the execution results of failed commands are
recorded.
3. REC_NON: indicating that the execution results of all the commands are not
recorded no matter whether the commands are executed successfully.

Number of the RXU chain or ring. The value scope is 0~11 for Non-SingleRAN
BTS and 0~249 for SingleRAN BTS. The RXU chain No. is unique in the same
BTS. A maximum of 12 RXU chains can be configured in one BTS.

The first RXU chain number when combining two RXU chains to be one RXU
ring.
The second RXU chain number when combining two RXU chains to be one RXU
ring.
RF receive mode of the TRX.
The BTS3012, BTS3012AE, BTS3012II, BTS3006C, and BTS3002E do not support
Main Diversity.
The DBS3900 GSM and BTS3900 GSM support Four Diversity Receiver and Main
Diversity.
Speed reduction efficient of the logical port. When detecting link congestion
through IPPM, the system reduces the bandwidth rate of the logical port by
using the value of the bandwidth multiplied by this parameter.

Whether to allow the reassignment function

Whether to re-assign the radio channels on a different band or on the same


band. This can help minimize the decrease in service quality due to
interference, faulty TRX paths, or faulty project constructions.
IUO cell receive quality threshold (AMRFR), which is used for IUO handover
decision
IUO cell receive quality threshold (AMRHR), which is used for IUO handover
decision
One of the parameters that decide the underlay and overlay areas. The
underlay and overlay areas are determined by "RX_QUAL Threshold", "RX_LEV
Threshold", "RX_LEV Hysteresis", "TA Threshold", and "TA Hysteresis" together.
One of the parameters that decide the underlay and overlay areas. The
underlay and overlay areas are determined by "RX_QUAL Threshold", "RX_LEV
Threshold", "RX_LEV Hysteresis", "TA Threshold", and "TA Hysteresis" together.
Whether to use the downlink receive level as a condition in IUO handover
decision
With traffic control enabled, the BSC discards some paging messages. This
parameter specifies whether to record detailed information of paging messages
discarded by the BSC in the commissioning logs.
Speed reduction alarm recovery threshold
One of the parameters that decide the underlay and overlay areas.
If "Enhanced Concentric Allowed" is set to OFF, the underlay and overlay areas
are determined by "RX_QUAL Threshold", "RX_LEV Threshold", "RX_LEV
Hysteresis", "TA Threshold", and "TA Hysteresis" together; if "Enhanced
Concentric Allowed" is set to ON, the underlay and overlay areas are
determined by "RX_QUAL Threshold", "UtoO HO Received Level Threshold",
"OtoU HO Received Level Threshold", "TA Threshold", and "TA Hysteresis"
together.

Whether to use the downlink receive quality as a condition in IUO handover


decision
Whether to back up the data of the board

Interval for releasing the secondary links in the congestion state

Secondary link bandwidth that is released each time in the congestion state

Port for output LINE2(The actual value range may differ on the LMT )

Back-up port for output LINE2(The actual value range may differ on the LMT )

Port for output LINE1(The actual value range may differ on the LMT )

Back-up port for output LINE(The actual value range may differ on the LMT )

Switch of panel BITS1(2M)

Switch of panel BITS2(2M)

Whether to use SGSN clock source.Only the Gb interface board needs to set
this parameter. If the SGSN clock and the MSC clock have different clock
sources, the MSC clock must use the clock source of the SGSN clock. If the two
clocks use the same clock source, this parameter does not need to be set.
Region information of the IP BTS configured with local switching. Local
switching can be performed between only the BTSs that have the same region
information.
Absolute time of re-homing

Delay time of re-homing

Policy type of re-homing

Whether to re-initialize the neighboring cell pair for software synchronization


Cabinet number of the associated module. The associated two MRFUs or GRFUs
must be in the same cell.
Whether to enable the configuration of the "Extend Connection" attribute. The
"Extend Connection" attribute describes the cascading relationship of the
DFCB, which helps the DFCU perform the six-in-one function.
Function to be performed by two associated modules

Slot number of the associated module

Subrack number of the associated module


Tributary Number of the DFCB that is cascaded to the DFCU. The "Extend
Connection" attribute describes the cascading relationship of the DFCB, which
helps the DFCU perform the six-in-one function.
Remark

Purpose description of the route record

Remote NSVL ID of the Gb IP route


A key parameter that indicates how many times the BSC6900 broadcasts cell
messages. You can obtain the cell broadcast times by running the "DSP
GSMSCB" command.
The value 0 indicates no repeat.
When the cell supports Repeated Downlink FACCH, the BTS enables the
repeated transmission of FACCH frames if the measured downlink quality is
higher than "Repeated Downlink FACCH Threshold".

If the cell supports the Repeated Downlink FACCH function and the measured
downlink quality is lower than the downlink quality threshold, the BTS enables
the repeated transmission of FACCH frames.
When the cell supports Repeated Downlink SACCH, the BTS enables the
repeated transmission of SACCH frames if the measured downlink quality is
higher than the downlink quality threshold.
Whether to reserve the binding of the alarm ID and the alarm port
Whether to perform resource checks on the resource usage system and
resource management system. Resource checks can prevent resource hanging
in case of anomalies. Resource checks cover channel resources, transmit
resources, and BSC resources.
Indicating that during cell reselection, the level of the target cell should meet
the following condition: Level of target cell > [MAX (level of serving cell, "Cell
Reselection Level Threshold") + "Cell Reselection Hysteresis"]. In this way,
ping-pong handovers do not occur.

NC2 cell reselection interval in the same cell


The number of received Packet Measurement Report messages on the receive
level of the serving cell is measured continuously. When the statistical value is
greater than or equal to the value of this parameter, the normal reselection
decision is made.
If the number of times when the receive level of the serving cell within "Normal
Cell Reselection Watch Period" is lower than "Cell Reselection Level Threshold"
is greater than the value of this parameter, the normal cell reselection is
triggered.
This parameter specifies the number of the reserved PDCHs that are not used
for channel converstion in the dynamic transferable channel pool.
This parameter specifies the number of idle channels that should be reserved
on a cell after the TRX is shut down. When the number of idle channels on a cell
is smaller than this threshold, the BSC6900 enables a TRX. This parameter is
used to prevent the impact enabling or disabling delay on the efficiency of
channel assignment on the cell that is enabled with the TRX Intelligent
Shutdown feature.
Whether to withhold link breakdown alarms in case of BTS resets due to data
configurations

If OML links break down after BTS resets caused by data configurations and
recover within the period specified by this parameter, configuration reset
alarms are reported;
If OML links fail to recover within the period specified by this parameter, OML
link breakdown alarms are reported.
Interval for resetting the counter when the user fails to log in

Retry times after the peer response timer expires during NSVC reset

The waiting time from BTS detect OML disconnect to BTS reset.

Duration of the peer response timer during NSVC reset

Reason for activating the radio status procedure


Whether the HO RQD messages sent by the BSC to an MSC carry response
request cells. Response request cells are optional. They are used to inform the
MSC whether it needs to return HO REJECT messages when HO RQD messages
fail to trigger handovers.
Whether to resume broken download

Duration of the PPP/MP link restart timer

Duration of the PPP/MP link restart timer

Restoration type of the alarm

Time for the BSC to initiate the common measurement or information exchange
procedure after this procedure fails

While assigning channels, the BSC ensures that the sum of the number of
channels occupied by high-priority users and the number of idle channels
reserved for high-priority users is no smaller than this parameter. Every time
the BSC assigns channels to a user whose priority is lower than "Highest
Priority", it checks whether the sum of the number of channels occupied by
users of "Highest Priority" and the number of idle channels is larger than the
number of the reserved channels. If yes, the BSC normally assigns channels for
the user; if not, the BSC does not assign a TCHF.

Maximum number of levels that the BTS RF power decreases. This parameter is
used to control the decrease in the BTS RF power. If the value is too large, the
BTS power decreases too much. If the value is too small, the BTS power
decreases less and the power decrease effect is not good.

Interval for sending the radio resource indication messages. The TRX reports
the interference level for each of the channels that have been idle for the whole
measurement period.
This parameter is used by a BTS to inform the BSC6900 of the interference
levels on idle channels of a TRX. For details, see GSM Rec. 08.58 and 08.08.

Interval for executing the scheduled subtask


The unit is determined according to the time mode.
1. If the time mode is set to "DAILY_T" or "DAILY_C", the unit is day.
2. If the time mode is set to "WEEKLY_T" or "WEEKLY_C", the unit is week.
3. If the time mode is set to "MONTHLY_T" or "MONTHLY_C", the unit is month.

1. This parameter specifies whether to configure the DRFU, MRFU, GRFU, or


XRFU by slot or link.
2. When setting the BTS to support the configuration of the RFU by slot, set this
parameter to "YES". When setting the BTS not to support the configuration of
the RFU by slot, set this parameter to "NO".
3. If this parameter is set to "YES", you must enter the numbers of the subrack
and slot where the new board is located.
If you need to specify the CPRI connection relations (SFP port number and
cascading level) based on a rule that is different from the cabinet mapping rule
specified by the system, the parameters "RXU Chain Head Port No." and "Insert
RXU Position" must be specified.
4. If this parameter is set to "NO", you must set "TRX Board No.", "RFU Link No."
and "RXU Chain Head Port No.".

Satellite card protocol that is enabled to communicate with the satellite card
connecting to the DGPS. If "RGPS" is specified, it indicates that the RGPS
satellite card protocol is enabled to communicate with the satellite card
connecting to the DGPS. If "GPS" is specified, it indicates that the GPS satellite
card protocol is enabled to communicate with the satellite card connecting to
the DGPS.
Whether to support RAN information management (RIM). IN the RIM procedure,
RANs(Radio Access Network) can exchange messages through the core
network.
The loopback channel number when the port loopback mode is set to TDM
remote loopback

Time for disconnecting a call when the MS fails to decode the SACCH. Once a
dedicated channel is assigned to the MS, the counter S is enabled and the
initial value is set to this parameter value.
Each time an SACCH message is not decoded, the counter S decreases by 1.
Each time an SACCH message is correctly decoded, the counter S increases by
2. When the counter S is equal to 0, the downlink radio link is considered as
failed. Therefore, when the voice or data quality is degraded to an
unacceptable situation and it cannot be improved through power control or
channel handover, the connection is to be re-established or released.
Transmission mode on the Ater interface of the remote TC subrack. The
meaning of values is as follows:
STANDALONETC: not converged
MASTERINPOOLTC: control subrack for TC convergence
SLAVEINPOOLTC: non-control subrack for TC convergence
RNC ID of a 3G external cell. The value of this parameter must be consistent
with the data configuration at the RNC.
Internal index of a neighboring RNC. This parameter is set to 255 when the
neighboring RNC that serves the 3G external neighbor is not configured. You
can use the "LST GNRNC" command to check whether the neighboring RNC is
configured.
Internal index of a neighboring RNC
Name of a neighboring RNC. The name is used to uniquely identify a
neighboring RNC.
Name of the root certificate file

Identifies a router uniquely


Router port number. The setting of this parameter must be consistent with the
setting at the SGSN side.
Whether to allow the BTS to report the downlink voice quality index (VQI). The
VQI is used to indicate voice quality. It is calculated on the basis of BER, FER,
and frame stealing.
Cell reselection measurement report period in packet idle mode

Cell reselection measurement report period in packet transmission mode

Speed reduction alarm report threshold

Whether to allow the BTS to report the voice quality index (VQI). If this
parameter is set to Report, the BTS reports the VQI. The BSC6900 collects the
traffic statistics on a per VQI basis. There are 11 levels of speech quality. If the
level is lower, the speech quality is better. The traffic related to AMR and nonAMR is measured separately, and thus the speech quality is monitored.
For the purpose of accurately reflecting the radio environment of a network,
filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of enhanced
measurement reports received on signaling channels used to filter the
REP_QUANT value.
For the purpose of accurately reflecting the radio environment of a network,
filtering is performed on the measured values in several consecutive
measurement reports. This parameter indicates the number of enhanced
measurement reports received on voice channels used to filter the REP_QUANT
value.

Resource group number of the PATH


Resource management mode. The logical port working in the SHARE mode can
be shared by multiple carriers. The logical port working in the EXCLUSIVE mode
can be used by only one carrier.
The parameter indicates whether the resource group is shared or is used by a
specific telecom carrier.

Timer for punishing the neighboring cells when handover failures occur due to
resource-related causes, such as resources being insufficient

This parameter adjusts "Min RSCP threshold" to enable the selection of 3G


candidate cells based on cell priorities

This parameter determines the layers of 3G neighboring cells. If the measured


value of a 3G neighboring cell is lower than this threshold, the 3G neighboring
cell is positioned at the bottom layer, that is, layer 4.
RSD alarm triggering source

RSF alarm triggering source

Used for calculating C2. The MS with a large value can be assigned with high
access priority.

Average down-bandwidth of RSL link in BTS.

Differentiated service code of the specified RSL

RSL service priority

Average up-bandwidth of RSL link in BTS.

Specified RSL Vlan Id

Size of the RSL LAPD window

Reason for locking the configuration and management control rights

Threshold of the level difference between a neighboring cell and the serving
cell, based on which the BSC filters the measured values in the measurement
reports and collects traffic statistics during automatic neighboring cell
optimization and automatic frequency optimization. The filtering results and
collected traffic statistics are later submitted to NaStar for analysis. When a
measurement report shows that the signal strength difference between a
neighboring cell and the serving cell is larger than ("Relative Signal Strength
Threshold" - 64), related traffic statistics will be collected.
This is the description file for resetting the board. The reset file names of
different boards are different.
Name of the result file generated after the command is executed. If this
parameter is not specified, the name of the result file is automatically
generated in the format of BATCH_RST_YYYYMMDDHHNNSSmmm. The result file
is located in the ftp directory in the main area of the OMU, and you should not
add the path when entering the name. The flag of the main area can be queried
through the "LST OMUAREA" command. The characters (@, #, !, %, ^, &, *, [, ],
/, \, ', and ") cannot appear in the file name.

Whether to enable the restart function

Timer

Maximum number of TCH channels reserved for emergency call users

Parameter 1 reserved for future use.

Parameter 10 reserved for future use.

Parameter 2 reserved for future use.

Parameter 3 reserved for future use.

Parameter 4 reserved for future use.

Parameter 5 reserved for future use.

Parameter 6 reserved for future use.

Parameter 7 reserved for future use.

Parameter 8 reserved for future use.

Parameter 9 reserved for future use.


Number of reserved idle channels. If this parameter is set too small, the TRX
may be frequently enabled/disabled; if this parameter is set too large, idle TRX
will not be timely closed.
Recovery mode of the MSP protection group

Routing context. The routing context identifies a specified route. If the routing
context is to be configured, its value must be negotiated between the two ends.

Ratio of the RTCP path bandwidth to the A interface bandwidth. According to


the Real-time Transport Control Protocol (RTCP), the BSC6900 and the MSC
negotiate the bandwidth occupation rate of the user plane on the A interface,
that is, the bandwidth occupied by the data packets generated during the
negotiation.
Whether to enable the real-time transport control protocol (RTCP) function. The
BSC6900 and the MSC negotiate whether and how to compress the data over
the A interface according to the RTCP. The setting of this parameter on the
BSC6900 side must be consistent with that on the MSC side. This parameter is
valid only when IP transmission is used over the A interface.

Destination IP address

Routing mask

Index of a route. The index is unique in a BTS.


It is used to calculate the round-trip time of the protocol stack and the RTO
value. The value must be smaller than "RTOBETA". In the case of the fixed
value of the "RTOBETA", the larger the value is, the less the link delay
sensitivity is.
It is used to calculate the round-trip time of the protocol stack and the RTO
value. The value must be greater than "RTOALPHA". In the case of the fixed
value of the "RTOALPHA", the larger the value is, the less the link delay
sensitivity is.

When the "RTOMIN" and "RTPMAX" parameters are set to fixed values, the
larger the value is, the longer the check of the link is.

When the "RTOMIN" parameter is set to a fixed value, the larger the value is,
the longer the check of the link is.
When the "RTOMAX" parameter is set to a fixed value, the larger the value is,
the longer the check of the link is.
Whether to measure the delay on the link between the BTSs that serve the
calling MS and the called MS respectively

Maximum number of RTTI TBFs that can be multiplexed on the PDCH. A PDCH
can be assigned when the number of RTTI TBFs on it is smaller than the value
of this parameter. This parameter is valid only when its value is smaller than or
equal to "MSRD PDCH DL Multiplexing Threshold".

Type of the route. When the BTS does not support IP over E1, the parameter
Route Type needs to be set to NEXTHOP(Next Hop). When the BTS supports IP
over E1, the parameter Route Type needs to be set to OUTIF(Out Interface)
because the packets at the data link layer are encapsulated according to Pointto-Point Protocol (PPP) and the peer IP address is unknown. The benefit of
setting Route Type to OUTIF(Out Interface) is that the configuration of the route
needs not to be changed after the peer IP address is changed.
Logical port speed increase step. When detecting the available bandwidth
increase through IPPM, the system increases the bandwidth of the logical port
by using this parameter.
Bandwidth increase step adjustment period. This parameter indicates the
period to increase the bandwidth of the logical port. Note that the actual
bandwidth increase step adjustment period is the packet drop ratio Statistics
period multiplied by this parameter value.

R-version number of the BTS software

Receive bandwidth of IP path

Receive bandwidth

Minimum receiving power level for the MS in the cell to access the system
For AMR FR voice services, a fixed amount of offset is added to the
corresponding grade of the received signal quality for the interference
handover of non-AMR FR voice services.
Minimum received signal level of the MS. This level is reported in the system
information. This parameter specifies the minimum receive level of an MS to
access the BSS. For details. see GSM Rec. 05.08. The value of this parameter
ranges from 0 to 63 (corresponding to -110 dBm to -47 dBm).

Whether to use the emergency handover algorithm in case the receive level of
the MSs drops rapidly, thus preventing call drops.

Threshold for the interference handover of Non-AMR FR voice services. AMRFR


refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Threshold for the interference handover of Non-AMR FR voice services. AMRFR
refers to Adaptive Multi-Rate Full Rate.
Number of the RXU chain to which the RXU belongs

Number of the RXU chain. The RXU chain No. is unique in one BTS.

Number of the RXU chain where the board is located

Index type of the RXU

Type of the RXU board index

Name of the RXU

Name of the RXU board. The RXU name is unique in one BTS.

Name of an RXU

Position number of the RXU on the RXU chain

Position No. of the RXU board on the RXU chain

Position of the RXU board on an RXU chain

Type of the RXU board


Whether to enable the switch to set the S1 value. S1 byte, also called the
synchronization status byte, is one of the optical connection parameters.
S1 sending value. It is a synchronization status byte used by the local end to
examine the quality of the received clock signals before the local end switches
to a clock source with higher quality. The smaller the value of S1 is, the lower
the clock quality is.

Whether to enable the special analog alarm.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

The value of this parameter consists of 32 bits, each of which determines


whether to enable the corresponding special analog alarm. "0" indicates that
the alarm is enabled, and "1" indicates that the alarm is disabled. When an
item is selected, the corresponding analog alarm switch is disabled. The
available items are BT1_DISABLE, AH_DISABLE, AT1_DISABLE, AT2_DISABLE,
and BT2_DISABLE.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether the MSC independently processes the trunking services. When this
parameter is set to YES, the MSC independently processes the trunking
services, that is, the trunking services are processed only by this MSC.
Whether an MS supports the SAIC function. Single Antenna Interference
Cancellation (SAIC) is used to reduce the impact of interference on the
reception of downlink signals through a signal processing technology. An MS
enabled with SAIC has improved ability of anti-interference. After SAIC is
enabled, the thresholds for BTS/MS Power Control are adjusted to improve the
radio performance of the BSS.
Adjustment step of the downlink signal quality threshold in power control
algorithm II for MSs that support SAIC. The network side uses a lower downlink
signal quality threshold for SAIC-supported MSs in power control, thus lowering
the transmit power of the corresponding BTS and reducing the interferences in
the whole network.
Adjustment step of the downlink signal quality threshold in power control
algorithm III for MSs that support SAIC. The network side uses a lower downlink
signal quality threshold for SAIC-supported MSs in power control, thus lowering
the transmit power of the corresponding BTS and reducing the interferences in
the whole network.
The value of this parameter consists of five bits, which determines whether to
enable the alarms. "0" indicates that the analog alarm is enabled, and "1"
indicates that the analog alarm is disabled.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Index of a cell with the same coverage as the current cell

Index type used when the command is executed

The BSC6900 checks the load of the same coverage cell of the target cell once
a minute. When the number of times in which the load of the same coverage
cell is lower than "Same Coverage Cell Load Threshold" is equal to the value of
this parameter, the target cell is disabled.

A cell that can be disabled is allowed to be disabled only when the load of the
same coverage cell is lower than this threshold for a period.
Name of the same coverage cell

This parameter is used by the BTS to inform the BSC6900 of radio link
connection failure.
When the BTS receives the SACCH measurement report from the MS, the
counter for determining whether a radio link is faulty is set to the value of this
parameter. Each time the BTS fails to decode the SACCH measurement report
sent by the MS, the counter decreases by 1. If the BTS successfully decodes the
SACCH measurement report, the counter increases by 2.
When the value of this parameter is 0, the BTS regards the radio link as faulty.
The BTS sends a connection failure indication message to the BSC6900. The
number of SACCH multi-frames and the radio link failure counter in the system
message specify the radio link failure time on the uplink and that on the
downlink respectively. The judgment standard is whether the measurement
report in SACCH is correctly decoded.

The value of this parameter consists of three bits, which determines whether to
enable the alarms. "0" indicates that the alarm is enabled, and "1" indicates
that the alarm is disabled.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to enable the special alarm switch.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Level specifications of special Boolean value alarms. Two specifications are


available: high level and low level. By default, only alarms of the door status
sensor are low level, and alarms of the water sensor, smoke sensor, and
infrared sensor are high level.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Whether to enable the energy saving function of the TRX for the BTS3002E.

Whether to enable the special Boolean alarms, that is, water sensor alarm (bit
0), smog sensor alarm (bit 1), and door sensor alarm (bit 2). All the Boolean
alarms are enabled by default. "0" indicates that the alarm is enabled, and "1"
indicates that the alarm is disabled.The available items are WS_DISABLE,
SS_DISABLE, and GS_DISABLE~2.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Number of the BTS. The BTS is numbered uniquely in a BSC.

Name of the BTS. The BTS is named uniquely in a BSC.

This parameter indicates that when the MS reports the EMR, it adds the value
of this parameter to the received signal level, and then converts the result into
the RXLEV value. For details, see GSM Rec. 05.08.
If the SCALE_Order reported by the MS is 10 dBm, level values 0-63 map with
-100 dBm to -37 dBm.
If the SCALE_Order reported by the MS is 0 dBm, level values 0-63 map with
-110 dBm to -47 dBm.
If the SCALE_Order reported by the MS is Automatic, the MS chooses the least
SCALE while ensuring that the MS can report the most strong level.

DSCP corresponding to the streaming service

When the network receives measurement reports, in consideration of the


accuracy of a single measurement report, the measurement values in certain
measurement reports are filtered to represent the radio operating environment.
The parameter specifies the number of measurement reports used for filtering
measurement information of the serving cell.

Number of the cell where the TRX reside. The cell is numbered uniquely in a
BSC.
Name of cell 1

A key parameter that indicates the coding scheme of a simple cell broadcast
message

Number of the sub-channel


Command string of the scheduled subtask. This command can be only a service
command, and the system command cannot be added to the scheduled
subtask.
Type of querying used to set the measurement report collection scope.

Indicates the index of the inter-subrack connection path

Scrambling code of a 3G cell. The scrambling code is used to differentiate


terminals or cells. It is used after spread spectrum. Therefore, it does not
change the bandwidth of signals, but only distinguishes the signals from
different sources. Through scrambling, multiple transceivers can use the same
codes for spread spectrum. Scrambling is used to distinguish terminals on the
uplink and to distinguish cells on the downlink.

Start serial number of the alarm record

SCTP link number of XPU board. This number identifies an SCTP link uniquely.

Start date of the alarm record. By default, the start date is 2000-01-01.

Start date of the alarm record. By default, the start date is 2000-01-01.

Maximum number of days for storing history alarms

Date when the scheduled task is started

SD alarm triggering threshold

Start date

Start date of the daylight saving time (DST)

Number of SDCCH channels. Rules for SDCCH channel allocation: 1. Allocate


channels 1 and 3 of main frequency B preferentially. 2. Allocate channels 1, 3,
5, and 7 according to the physical position order of the frequencies. Thus, the
maximum number of SDCCH channels is (actual number of frequencies - 1)
*4+2.
Whether a call must camp on the SDCCH for a specific duration before being
assigned with a traffic channel.

Duration for a call camping on the SDCCH before being assigned with a traffic
channel.

Level threshold for measuring the number of call drops on SDCCH. When call
drop occurs on the SDCCH, the BSC6900 determines whether the downlink
receive level is lower than this threshold. If the downlink receive level is lower
than this threshold and the TA is smaller than the TA threshold of the serving
cell, the number of call drops on SDCCH (receive level) is incremented by one.

Quality threshold for measuring the number of call drops on SDCCH. When call
drop occurs on the SDCCH, the BSC6900 determines whether the downlink
quality level multiplied by 10 is higher than this threshold. If all the following
four conditions are met, the number of call drops on SDCCH (receive quality) is
incremented by one. First, the downlink quality level multiplied by 10 is higher
than this threshold. Second, the TA is smaller than the TA threshold of the
serving cell. Third, the uplink level is higher than "UL Level Threshold for
SDCCH Call Drop". Finally, the downlink level is lower than "DL Level Threshold
for SDCCH Call Drop".

Level threshold for measuring the number of call drops on SDCCH. When call
drop occurs on the SDCCH, the BSC6900 determines whether the uplink receive
level is lower than this threshold. If the uplink receive level is lower than this
threshold and the TA is smaller than the TA threshold of the serving cell, the
number of call drops on SDCCH (receive level) is incremented by one.

Quality threshold for measuring the number of call drops on SDCCH. When call
drop occurs on the SDCCH, the BSC6900 determines whether the uplink quality
level multiplied by 10 is higher than this threshold. If all the following four
conditions are met, the number of call drops on SDCCH (receive quality) is
incremented by one. First, the uplink quality level multiplied by 10 is higher
than this threshold. Second, the TA is smaller than the TA threshold of the
serving cell. Third, the uplink level is higher than "UL Level Threshold for
SDCCH Call Drop". Finally, the downlink level is lower than "DL Level Threshold
for SDCCH Call Drop".
Whether to allow SDCCH dynamic allocation, that is, whether to allow dynamic
conversion between TCHs and SDCCHs.
Enable SD

Whether to enable the SDCCH quick handover test function. If this parameter is
set to Yes, the BSC6900 initiates intra-cell SDCCH handover as soon as the MSC
issues an encrypted command to the MS. Thus, the forwarding encrypted
signaling can be transmitted and received on a new signaling channel. In this
way, the network security is improved.
This parameter specifies whether the BSC6900 automatically shuts down the
power amplifier of the TRX to save power when the BTS is powered by batteries
after a power failure.

After a new SDCCH is assigned to an MS, the MS can be handed over to another
channel only if the time during which the MS occupies the SDCCH is longer than
the period specified by this parameter.

Maximum number of discarded MRs allowed on the SDCCH in a power control


period

Period in which level penalty is performed on the neighboring cells of the cell
where a fast-moving MS is located. The neighboring cells must be located at
the Macro, Micro, or Pico layer other than the Umbrella layer.

Level value of the penalty that is performed on the neighboring cells of the cell
where a fast-moving MS is located. The neighboring cells must be located at
the Macro, Micro, or Pico layer other than the Umbrella layer.

DSCP corresponding to the signaling


Specifies the SF and SD event priority
High temperature threshold for triggering power shutdown of the battery. If the
power shutdown upon battery high temperature is enabled and the battery
temperature is higher than the value of this parameter, the battery is
automatically powered off.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Sliding time window for collecting statistics on the alarms that disappear in a
specified period of time.Sampling time window. In the period specified by this
parameter, the duration in which the alarm persists is accumulated.
Sliding time window for collecting statistics on the alarms that occur in a
specified period of time.This parameter is similar to the sampling time window.
In the period specified by this parameter, the duration in which the alarm
persists is accumulated.
Low voltage threshold for triggering power shutdown of the battery. If the
power shutdown upon low voltage is enabled and the load voltage is lower than
the value of this parameter, the battery is automatically powered off.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Whether to allow the MS to search for a 3G cell when the BSIC must be
decoded
Self Software Version

This parameter specifies whether the SI Type 3 message contains the 2QUATER
indicator.

Whether to report BSS INVOKE TRACE message. When the parameter is set to
YES, the BSC sends a BSS INVOKE TRACE message to the MSC if receiving an
MSC INVOKE TRACE or BSS INVOKE TRACE message from MSC in the case of an
outgoing BSC handover. If the BSC does not receive the message, the BSC does
not send a BSS INVOKE TRACE message to the MSC.

Whether to report the classmark queried by the BSC6900 to the MSC


Whether to send a CONFUSION message to the MSC. This parameter specifies
whether to send a message carrying fault location information to the MSC if the
BSC receives a message that cannot be decoded over the A interface.
If this parameter is set to No, the BSC responds with an SAPI N'Reject message
against the DL short message after hangup.
Priority of the notification message transmission on the FACCH. From high to
low, the priorities are A, B, 0, 1, 2, 3, 4 and No Priority. No Priority is the lowest.
When the priority of the group call is higher than or equal to the value specified
by this parameter, the notification message is sent on the FACCH.
Priority of the paging message transmission on the FACCH. From high to low,
the priorities are A, B, 0, 1, 2, 3, 4 and No Priority. No Priority is the lowest.
When the priority of the group call is higher than the value specified by this
parameter, the paging message is sent on the FACCH.

The time for BTS reset.

Whether the BSC sends the System Information Type 2ter message.

Whether the BSC sends the System Information Type 5ter message.
Whether the SI Type 3 message contains the 3G Early Classmark Sending
Restriction field. The 3G Early Classmark Sending Restriction field is used to
notify the MS of whether the early classmark message contains the 3G
classmark message. This parameter is valid for dual-mode MSs and is invalid
for single-mode MSs.
Split position on the RXU chain

Whether to enable the BTS to support the separation between the physical and
logical. Whether the BTS supports the separate mode. When a BTS is in
separate mode, the physical boards are separate from the logical TRXs, that is,
a physical board may exist without being configured with any logical TRX. When
a BTS is in non-separate mode, a one-to-one mapping exists between the
physical board and the logical TRX.
Number of the command listening port of the server. You should not use any
port number occupied by other applications.
Number of the data port of the server in active mode. You should not use any
port number occupied by other applications.
Delivery serial number of the RET antenna

IP address of the FTP server to be visited by the FTP client


Service mode of the BSC6900. This parameter specifies configuration mode of
subracks.
Service bearer mode of the BTS

Service bearer mode of the BTS

Name of the command function

Service type of the BTS. The QoS processing depends on the DSCP, VLAN ID,
and VLAN priority that vary according to the service type.

Whether to enable the diesel engine parameters to be configured

Whether to enable the environment temperature alarm parameters of the


APMU to be configured. The APMU of the APM30 type does not support this
parameter.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Whether to enable the environment temperature parameters to be configured.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Whether to enable the environment humidity alarm parameters of the board to


be configured.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Number of the SFP port. If the switching relation is added on the SFP port, it
indicates that the SFP port is used to connect the BBU and no RXU chain or ring
can be configured on the port.
Available capacity of the SGSN
Name of the SGSN
Length of the NRI(Network Resource Identifier) or NULL-NRI. The length
determines the maximum value of the NRI and NULL-NRI.
Special NRI(Network Resource Identifier). Each SGSN pool has one NULL-NRI.
When the NRI value in the TLLI of the MS uplink/downlink service data equals
NULL-NRI, the BSC6900 reselects an SGSN for the MS.
Whether to enable the SGSN pool function. With SGSN pool, a BSC6900 is
connected to multiple SGSNs in the pool, and load balancing and resource
sharing between these SGSNs are allowed. In this manner, the PS services are
processed by the SGSNs in the SGSN pool in the most efficient way. This
reduces inter-MSC handovers and node redundancy backup.

Protocol version supported by the SGSN

Administrative state of the SGSN. The value "ALLOW" indicates that the SGSN
can handle the PS services normally. The value "UNISTALL" indicates that the
SGSN does not permit new PS services to access the network and the ongoing
PS services are not affected. The value "DENY" indicates that the SGSN denies
all PS services.
Usage threshold of the CPU for call access from other CPU. If the usage of the
CPU exceeds the threshold, the call access request is discarded.
Slot number of the load sharing interface board

Whether to allow sharing

Shield flag of the alarm

This parameter specifies the delay time before shutting down the TRXs when
the BTS experiences a power failure.

Whether the BSC sends a System Information Type 2ter message to a nondualband cell. When the parameter is set to YES, the cell does not send the
System Information Type 2ter message if the cell is not configured with interfrequency neighboring cells. If the cell is configured with inter-frequency
neighboring cells, the cell sends the System Information Type 2ter message.
When the parameter is set to NO and "Send System Information 2ter " is set to
YES, the cell sends the System Information Type 2ter message. Otherwise, the
cell does not send the message.

Whether to enable a handover between signaling channels

Number of times that the downlink signal strength exceeds the threshold

Uniquely identifies a signaling link set

Uniquely identifies a signaling link set


ID of an M3UA link in the specified link set
Signaling local weight over the local NSVL. When this parameter is set to a
larger value, the NS is more likely to select this IP point according to the load
sharing function of the NSVC link of the IP network, if the NS sends a signaling
message.
Signaling local weight over the remote NSVL. When this parameter is set to a
larger value, the NS is more likely to select this IP point according to the load
sharing function of the NSVC link of the IP network, if the NS sends a signaling
message.
Priority of the signaling service.0 is the highest priority.

Number of times that the downlink signal is measured


Number of measurement reports used for averaging the signal quality of
signaling channels. This parameter helps avoid sharp drop of signal levels
caused by Raileigh fading and to ensure correct handover decisions.
ID of an MTP3 link in a specified link set
Number of measurement reports used for averaging the signal strength of
signaling channels. This parameter helps avoid sharp drop of signal levels
caused by Raileigh fading and to ensure correct handover decisions.
Minimum interval between the successful TBF establishment and the first
initiation of the Packet Timeslot Reconfiguration procedure
Single pass exclude MSISDN number 1. One-way audio means that only one
party in a call can hear the voice. Certain numbers, such as the premium rate
number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 10. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 11. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 12. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.

Single pass exclude MSISDN number 13. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 14. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 15. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 16. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 17. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 18. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 19. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 2. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 20. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 3. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 4. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 5. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 6. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 7. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Single pass exclude MSISDN number 8. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.

Single pass exclude MSISDN number 9. Certain numbers, such as the premium
rate number, are not used for the single pass check. The number is stored in
character string.
Source IP address

Source IP address
Log of which site need to be collected.
Zone where the BTS synchronizes with other BTSs. Only two BTSs with the
same synchronization zone can be synchronized in a synchronization task.
The IP address must be a valid class A, B, or C address, and it cannot be a
broadcast address or network address.
No. of the location group under the BTS. The location group No. is unique for
each BTS.

Self-loop type. The precautions are as follows:


1. If the self-loop type is set to "E1SELFLOOP" and the BTS type is BTS3002C,
BTS3001C, or BTS3001CP, the transmission board type can be set to only
"Active TMU/MMU/IOMU/DOMU". If the BTS type is BTS3006C or BTS3002E, the
transmission board type cannot be set to "Active/Standby TMU".
2. If the self-loop type is set to "IASUSELFLOOP", only 3002C, 3006C, 3002E
support IASU self loop type, and when the BTS type is BTS3002C, the
transmission board type can be set to only "Active DOMU".

Signaling route load sharing. In the value, the number of 1s (represented by n)


determines the maximum number (2) of routes for the load sharing. For
example, B0000 indicates that up to one route is used for the load sharing,
B0001 and B1000 indicate that up to two routes are used for the load sharing.
The additional routes are not used for the load sharing. The AND operation
between this value and " signaling link mask " in the link set is equal to 0.
If no handshake message is received from the peer within the delay, the slave
service is activated. A slave service object provides services at the peer BSC
and its configuration data is backed up at the local BSC. A slave service object
provides services at the local BSC only when the peer BSC is faulty or when all
the signaling links on the A interface of the peer BSC are faulty.

Type of the start date. "WEEK" indicates that the start date is a weekday.
"DATE" indicates that the start date is a month day. "DATEWEEK" indicates the
start date is expressed by a combination of weekday and month day.
Index of the SMLC

Whether the built-in SMLC or external SMLC is used in the BSS.

Smog alarm switch

Month in which DST starts

Number of CPU usage samples involved in the calculation of the average CPU
usage in the sliding window
Number of the slot where the XPU board is located

Number of the slot

Number of the slot

Number of the slot. The subrack number and slot number uniquely identify a
board.

Slot number of the XPU board bound to the NSE


Number of the slot where the alarm is generated
Number of the slot where the alarm is generated, the number of the slot where
the OMU board is positioned is not supported

Number of the slot where the BTS board is located

Slot No. of the subsystem where the Iur-g common connection is established

Number of the slot where the XPU board is located

Number of the slot

A key field used to identify the Ater timeslot and indicate the number of the
Ater interface timeslot

Indicates the slot number for running this command

Slot number for running this command

Number of the slot


Slot number of board to which Pb signaling link belongs

Number of the slot where the BTS board is located

Number of the slot where the port is located

Slot number of the BSC6900 board that is connected to the BTS

Number of the slot where the BTS board is located.

RF send mode of the TRX.


The BTS3006C and BTS3002E do not support Wide Band Combining, Power
Booster Technology, DPBT, or Transmitter Independent or Combining.
The DBS3900 GSM GRRU does not support Wide Band Combining, Transmitter
Independent or Combining, Power Booster Technology, or DPBT.
The BTS3900 GSM and BTS3900A GSM do not support Transmitter Independent
or Wide Band Combining.

The connection mode between the DRRU and the antenna.

The connection mode between the DRFU and the antenna.

The connection mode between the MRRU/GRRU and the antenna.

The connection mode between the MRFU/GRFU and the antenna.

The connection mode between the BTS3900E and the antenna.

Synchronization period of the SNTP client service


As an integer, the OSP code can be expressed by a decimal digit or a
hexadecimal digit. If the OSP code is expressed by a hexadecimal digit, H' is
added before the number.

Number of bits contained in the signaling point code


OSP code expressed in the form of segments 8-8-8, see the parameter "Signal
point data format" of the "ADD OPC"
Start CIC of the E1/T1 of the Pb interface

Data format of the specified signaling point.


When this parameter is set to "WNF", the SPC is expressed in the form of an
integer number.
When this parameter is set to "NDF", the SPC is expressed in three segments.
The number of bits included in each segment depends on the setting of the
signaling point code bits parameter.
When the signaling point code bits parameter is set to "BIT14", the number of
bits included in each segment is 3, 8, and 3.
When the signaling point code bits parameter is set to "BIT16", the number of
bits included in each segment is 4, 8, and 4.
When the signaling point code bits parameter is set to "BIT24", the number of
bits included in each segment is 8, 8, and 8.
Assume that the signaling point code bits parameter is set to "BIT14" and the
SPC is expressed in three segments 5-7-2. You can perform the following steps
to convert this SPC to an integer:
1. Convert the value in each segment to a binary number and fill 0s into a
segment if the number of bits included in that segment does not meet the
requirements. The binary number of value 5 in the first segment is 101, which
is of three bits. Thus, you need not to fill 0s into the first segment. The binary
number of value 7 in the second segment is 111. As previously stated, when
the signaling point code bits parameter is set to "BIT14", eight bits must be
included in the second segment. Thus, the second segment is put as 00000111.
Accordingly, you can calcuate the binary number of the value in the third
segment. The binary number of 5-7-2 is 101 00000111 010.
2. Convert this binary number to a decimal number. The decimal form of this
binary number is 10,298.

This parameter is used for load control. It determines whether the users of
special access class are allowed to access the network. Value 1 indicates that
access is not allowed. Value 0 indicates that access is allowed.

The value of this parameter consists of seven bits. Each bit determines whether
to enable the one-way Boolean alarm. "0" indicates that the one-way Boolean
alarm is enabled, and "1" indicates that the one-way Boolean alarm is disabled.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

The value of this parameter consists of five bits. Each bit determines whether
the one-way Boolean alarm is triggered by low level or high level. "0" indicates
that the alarm is triggered by high level, and "1" indicates that the alarm is
triggered by low level.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
If the number of one-way mute events exceeds the value of "Speech Channel
Alarm Threshold" within this period, then the BSC reports the Speech Channel
alarm.

Whether to contain the information element of Speech_Ver in the Assignment


Complete message

Whether to contain the information element of Speech_Ver in the Handover


Perform message
Whether to contain the information element of Speech_Ver in the HO_REQ_ACK
message
Whether to contain the information element of Speech Ver in the HO_RQD
message
Speech version mode that the BTS uses for the VGCS call number in the
timeslot in the TRX in fallback mode
Speech version mode that the BTS uses for the VGCS call number in the
timeslot in the TRX in fallback mode
Speech version configured on the TRX timeslot when the BTS works in fallback
mode. When "CHNTYPE" of the TRX timeslot is set to "FULLTCH", value 0 of this
parameter indicates FR and value 1 indicates EFR; when "CHNTYPE" of the TRX
timeslot is set to "HALFRCH", this parameter is invalid.
Rate over the GE electrical port. When this parameter is set to 1000M, the GE
electrical port performs negotiation at the rate of 1000 Mbit/s. If, however, the
negotiation result is not 1000 Mbit/s, the negotiation fails. When this parameter
is set to AUTO, the GE electrical port performs auto negotiation, and the
negotiation result can be either 100 Mbit/s or 1000 Mbit/s.

Level value of the penalty that is performed on the neighboring cells of the cell
where a fast-moving MS is located. The neighboring cells must be located at
the Macro, Micro, or Pico layer other than the Umbrella layer.

Period in which penalty is performed on the neighboring cells of the cell where
a fast-moving MS is located. The neighboring cells must be located at the
Macro, Micro, or Pico layer but not the Umbrella layer.

Whether to support SPLIT_PG_CYCLE on CCCH. The parameter SPLIT_PG_CYCLE


is used to define the DRX period. You can specify whether the paging group
based on SPLIT_PG_CYCLE is supported on CCCH for the BTS and the MS. Yes:
the paging group based on SPLIT_PG_CYCLE is supported on CCCH. No: the
paging group based on SPLIT_PG_CYCLE is not supported on CCCH.
This parameter specifies whether the BSC6900 supports the cell broadcast
function and whether the BSC6900 supports simple cell broadcast or standard
cell broadcast.
If the BSC6900 supports standard cell broadcast, the BSC6900 should be
connected to the CBC.
Whether to support the common bidirectional measurement procedure on the
Iur-g interface.
Whether to support the bidirectional information exchange procedure on the
Iur-g interface.
Whether to support In Inter-RAT Inter-cell PS Handover. The MS in the UMTS cell
can be handed over to the BSC local cell through PS handover algorithm.
Whether support Out Inter-RAT Inter-Cell PS Handover. The MS in the BSC local
cell can be handed over to the UMTS cell through PS handover algorithm.
Whether the function of Network Assisted Cell Change (NACC) resource
guarantee is allowed. In NC2 or NACC cell reselection, if this parameter is set to
YES, dynamic channels are requested in the target cell.
Whether the BSC forwards the paging message from the trunking MSC to the
MS. When this parameter is set to YES, the BSC forwards the paging message
from the trunking MSC to the MS and forwards the corresponding paging
response from the MS to the trunking MSC.

Whether to enable the layer 3 check mechanism on the LAPD links. If the
PCU_BSC_LAPD_CHECK_ACK message cannot be received on one Pb link, the Pb
link is in single pass mode. Send another two PCU_BSC_LAPD_CHECK_ACK
messages. If the PCU_BSC_LAPD_CHECK_ACK message is still not received on
the Pb link, set the Pb link to fault state and report the ONE PBSL Link.

Whether to enable the enhanced resource check on the Pb interface.


The introduction of enhanced resource check is to improve the efficiency of
resource checking and define the dependencies of resource status.
The external PCU initiates the enhanced resource check. The resources to be
checked, consisting of the cell resources, channel resources, and PCIC
resources, are provided in list form in the check message, thus reducing the
number of messages on the Pb interface and improving the efficiency of
checking.
The external PCU sends the check message to the BSC. The BSC divides the
check message into three independent check messages, each containing one
type of resource to be checked, and sends the check message to the
corresponding module for resource checking.

Whether to enable the single pass check function on the Pb links between the
BSC and the external PCU. When the Pb link is in single pass mode, a
corresponding alarm is reported to the maintenance terminal, and the Pb link is
set to broken link state or the priority of the Pb link is lowered.
Whether to enable the PCIC check function on the Pb links between the BSC
and the external PCU. When the configuration of the PCIC of the BSC is
inconsistent with that of the external PCU, a corresponding alarm is reported to
the maintenance terminal, the Pb interface circuit with inconsistent
configurations at two ends are blocked, and the priority of the Pb link is
lowered.
Whether to support RAN Sharing.RAN sharing refers to the technique that the
GBSS equipment is categorized into multiple logical GBSS equipment, thus
operators can share the GBSS equipment to cover the same area.
Cell supports reduced latency capability. This parameter is used to reduce the
latency during the transmission, thus improving the user experience for
conversational services.
whether the main operator enables the RanSharing function. If the RanSharing
function is enabled, one to three co-operators can be configured to share the
BSS.
Whether the FTP client supports the state firewall

Uniquely identifies an OSP

Whether a base station supports normalized data configuration. Normalized


data configuration means that the cabinets, subracks, slots, transmission ports,
and user-defined alarm ports of a base station under a multi-mode BSC use the
same numbering schemes, and that the boards of the base station are
uniformly named.

Whether the data configuration of the SingleRAN BTS supports normalized


SingleRAN mode. Normalized SingleRAN mode means that the rules of defining
cabinet number, subrack number, and slot number of the SingleRAN BTS are
normalized.

Whether the data configuration of the SingleRAN BTS supports normalized


SingleRAN mode. Normalized SingleRAN mode means that the rules of defining
cabinet number, subrack number, and slot number of the SingleRAN BTS are
normalized.

A cell Index must be unique in one BSC6900


. It is used to uniquely identify a cell.

Name of a cell

A source cell index must be unique in one BSC. It is used to uniquely identify a
source cell.
The value of this parameter ranges from 0 to 2047.
Name of a source cell

Source cell ID

The batch file to be executed: The content of the batch file consists of service
commands to be executed in batches. The source file is located in the FTP
subdirectory of the OMU installation directory, and you should not add the path
when entering the name. The characters (@, #, !, %, ^, &, *, /, ., [, ], \, :, ?, ', ",
<, >, and |) cannot appear in the file name.

Priority of the clock source


Priority of the clock source. There are four priorities (in descending order): 1, 2,
3, 4.
Whether the currently used handover algorithm in the source cell is HO
Algorithm I or HO Algorithm II
Source IP address of BFD Session.
Local area code (LAC) of the source cell

Mobile country code (MCC) of the source cell


Identifies a maintenance point in the maintenance group
Mobile network code (MNC) of the source cell
Source of timeslot cross

Type of the clock source.

Source timeslot mask

Number of the subrack

Number of the subrack

Number of the subrack

The subrack number uniquely identifies a subrack.

Subrack number of the XPU board bound to the NSE

Number of the subrack where the indicator alarm to be queried is generated

Number of the subrack where the BTS board is located


Subrack No. of the subsystem where the Iur-g common connection is
established
Number of the subrack where the XPU board is located

Number of the subrack

It is one key field of identifying the Ater timeslot and indicates the subrack No.
of the Ater interface timeslot.

Number of the subrack

The subrack number for running this command

Subrack number of board to which Pb signaling link belongs

Number of the subrack where the BTS board is located

Number of the subrack where the port is located

Subrack number of the BSC6900 board that is connected to the BTS

Number of the subrack where the BTS board is located

Number of the subrack at one end of the inter-subrack connection channel

Number of the subrack at the other end of the inter-subrack connection channel

Name of the subrack to be added

Number of the tributary

Type of the subrack

Sequence of alarm records


Traffic local weight over the local NSVL. When this parameter is set to a large
value, the NS is more likely to select this IP point according to the load sharing
function of the NSVC link of the IP network, if the NS sends a data message.
Traffic local weight over the remote NSVL. When this parameter is set to a
larger value, the NS is more likely to select this IP point according to the load
sharing function of the NSVC link of the IP network, if the NS sends a data
message.
The parameter specifies which type of service TRXs should be preferentially
processed when the PSU is faulty.
Service type of the IP interface board. The service type can be CS speech, CS
data, PS high priority, or PS low priority.

After a handover due to bad quality is successful, the penalty on the original
serving cell is performed within the "Penalty Time after BQ HO": the receive
level of the original serving cell is decreased by "Penalty Level after BQ HO", to
prevent ping-pong handovers.

CPU usage alarm clearance threshold


CPU usage alarm threshold. When the CPU usage exceeds the threshold, a CPU
usage alarm is reported. "CPU occupancy alarm clearance threshold" is smaller
than "CPU occupancy alarm threshold".
DSP usage alarm clearance threshold. When the DSP usage is lower than the
threshold, the DSP usage alarm is cleared.
DSP usage alarm threshold. When the DSP usage exceeds the threshold, a DSP
usage alarm is reported. "DSP occupancy alarm clearance threshold" is smaller
than "DSP occupancy alarm threshold".
When the network receives measurement reports, the measurement values in
several straight measurement reports are filtered to reflect the radio operating
environment for the sake of accuracy. This parameter specifies the number of
successive measurement reports that are used to determine the signal strength
on traffic/data channels.

When the network receives measurement reports, the measurement values in


several straight measurement reports are filtered to reflect the radio operating
environment for the sake of accuracy. The parameter specifies the number of
successive measurement reports that are used to determine the signal strength
on signaling channel.

Number of the subsystem

No. of the subsystem where the Iur-g common connection is established

Start synchronization number of the alarm record

After the time advancing handover is successful, the penalty on the original
serving cell is performed within the "Penalty Time after TA HO": the receive
level of the original serving cell is decreased by "Penalty Level after TA HO", to
prevent ping-pong handovers.

Start time of the alarm record. By default, the start time is 00:00:00.

Start time of the alarm record. By default, the start time is 00:00:00.
The operation time of the log record should be after this time. If this parameter
is not specified, the start time is not limited.
If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should
set this parameter.
The operation time of the log record should be after this time. If this parameter
is not specified, the start time is not limited.
A key parameter that indicates the date and time when the BSC6900
broadcasts cell messages

Start of DST

Start number of the alarm record

Whether to preferentially use the variable bitmap code when encoding the
frequency in the System Information and encoding the FH frequency in the
assignment or handover command

This parameter indicates whether the arrival of channel request messages is


controlled.
It indicates the start CIC of the A interface CIC segment. When operation mode
is set to OPC index, DPC group index, BSC ID, or CIC, the parameter is
mandatory.
It indicates the start CIC of the Pb interface CIC segment. If the search object
mode is set to search by the specified range, the parameter is mandatory.

This parameter specifies the start date of a period during which the TRX
Intelligent Shutdown feature is disabled.

When the environment temperature reaches the specified value of this


parameter, the heater is started.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

This parameter specifies the start month of a period during which the TRX
Intelligent Shutdown feature is disabled.

This parameter indicates whether the arrival of paging messages are


controlled.

This parameter indicates whether the arrival of PS resource request messages


is controlled.
Number of the start sub-timeslot
Time for which the BTS waits to start the fallback function after the OML is
interrupted. With this parameter, the BTS does not start the fallback function
when the OML is interrupted transiently.
This parameter specifies the start time for dynamically enabling the TRX
Intelligent Shutdown feature each day.

It indicates the start CIC of the A interface CIC segment. When Operation mode
is set to subrack number, slot number, port number, or CIC, the parameter is
mandatory.

It indicates the start CIC of the Ater interface CIC segment.

Number of the start timeslot

Whether to enable the smart temperature control mechanism of the FMUA.


Smart temperature control refers to the mechanism adopted by the FMUA to
adjust the fan speed, and thus to regulate the temperature according to the
environment temperature.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to enable the smart temperature control mechanism of the NFCB.
Smart temperature control refers to the mechanism adopted by the NFCB to
adjust the fan speed, and thus to regulate the temperature according to the
environment temperature.
Number of the start CIC. The C/C of each E1/T1 timeslot can be calculated on
the basis of this parameter. Assume that the start CIC is 100, the CIC of the E1
timeslots on the A interface will automatically be set to 100, 101, 102, 103, and
so on. Assume that the CIC of an E1 timeslot is 65535, the CICs of all
successive E1 timeslots are all 65535.

Number of the cabinet where the outgoing port of the BTS is located

Start date. The input format is YYYY&MM&DD.

Number of frequencies measured in each group (excluding the frequencies in


the original BA table).

Satellite flag
Start time
Whether to enable the EICC algorithm. Enhanced Interference Rejection
Combining combines the signals received by multiple antennas to obtain better
signals. EICC is mainly used in high traffic network where tight frequency reuse
is in place.
This parameter specifies whether the sending of system information 5, 5bis,
and 5ter can be stopped on the SACCH on the SDCCH after the BTS issues a
ciphering command.
Time for which the BTS waits to stop the fallback function after the OML is set
up. With this parameter, the BTS does not stop the fallback function when the
OML is set up transiently.
Whether to enable the signaling point with the signaling transfer function
Number of the outgoing port of the BTS where the monitoring timeslot is
located
Start time of frequency scanning

Number of the slot where the outgoing port of the BTS is located

Number of the subrack where the outgoing port of the BTS is located

Number of the sub-timeslot on the outgoing port of the BTS

Start time. The input format is HH&MM&SS.

Number of the timeslot on the outgoing port of the BTS

Type of the BTS.

ID of the BSC in the TC pool where an A interface circuit is blocked or unblocked

ID of the BSC in the TC pool to which an A interface E1/T1 is added

Command string that is transparently transmitted to the BTS


Maximum sub-frame length. This parameter indicates the maximum sub-frame
length for multiplexing. If the length of a sub-frame exceeds this value, the subframe is not multiplexed.

Maximum sub-frame length. The data stream to be multiplexed on the same


multiplexing channel must be of the same type, and the length of the packet
before multiplexing cannot exceed the maximum subframe length. If the length
of a packet exceeds the maximum subframe length, the packet is transmitted
without being multiplexed.

Number of the scheduled subtask

Subnet Number in a BSC


This parameter specifies whether the CS services preempt the sublink
resources of PS services.
Whether to allow the CS services to preempt the sublink resources of PS
services when the Abis resources are congested
Number of the sub-timeslot on the port
Sub-version No. of the TMU board. It is configured according to the actual
situation.
Whether the CIC circuits in use on the A interface can be assigned. When this
parameter is set to YES and the MSC assigns new calls to an ongoing A
interface circuit, the original calls (that are occupying the circuit) are released,
and the circuit is used by the new calls. When this parameter is set to NO and
the MSC assigns new calls to the ongoing A interface circuit, the new calls are
rejected, and the original calls are not affected.

Whether to use Back-up port for LINE2

Whether to use Back-up port for LINE1

Whether to support the broadcast of the cell name

Whether to support the high multislot class. High multislot class function
enables a single MS to be allocated with a maximum of five timeslots on the
uplink or downlink, thus improving the uplink or downlink throughput of a single
MS. The BSS supports the MS with high multislot classes from 30 to 34. A
maximum of five timeslots on the downlink can be assigned to an MS. If an MS
is of the high multislot class 34, a maximum of five timeslots on the uplink can
be allocated to the MS. Thus, the uplink and downlink throughput is increased
by 25%.The total number of timeslots on the uplink and downlink cannot
exceed six. That is, if five timeslots on the downlink are allocated to the MS,
then only one timeslot on the uplink can be allocated to the MS.

Whether to support dual transfer mode (DTM). The DTM allows an MS to use
the circuit switching service and the packet switching service at the same time.
This function must be supported by the network side.

Whether to support EDA. Extended dynamic allocation (EDA) enables the MS to


be allocated with more timeslots on the uplink, thus improving the uplink rate
and helping to transmit large amounts of data on the uplink.

Whether to support the enhanced DTM function. Comparing to the DTM, the
enhanced DTM improves the CS setup and release. During the CS service
setup, the PS service is not interrupted.

Whether the FE/GE BTS supports inter-BTS local switching

Support intracell handover to change the active speech version, then can
increase the usage of TFO(Tandem Free Operation) to improve the speech
quality.

Whether to support the cell list in the common measurement messages over
the Iur-g interface. When this parameter is set to YES, the local BSC can handle
the load information of the cells in the cell list carried in the received common
measurement messages. In addition, the BSC can carry the load information of
the cells in the cell list in the sent common measurement messages, such as
the common measurement report, common measurement initialization
response, common measurement initialization failure, and common
measurement failure indication.
Minimum timeslots between two successive channel requests. After sending the
access request, if the MS does not receive the response message after waiting
for the minimum timeslots between two successive channel requests, the MS
resends the access request.
Server IP address used on the SGSN side in the IP subnet dynamic configuration
procedure
Server UDP port number used on the SGSN side in the IP subnet dynamic
configuration procedure
Operating state of the environment alarm port
If this parameter is set to "ON", you must set "OMU automatic switchover
interval". Otherwise, "OMU automatic switchover interval" is not displayed.
Switch for authenticating objects. When the switch is enabled, the BSC system
authenticates the BTS objects of the user; when the switch is disabled, the BSC
system does not authenticate the BTS objects.
Whether to enable the alarm port

Power switch state.

Weekday on which DST starts

State of the panel port switch

Turn on or turn off the BFD protocol switch

Grace Protection Period Switch determines whether to enter the grace


protection period.
Switch for the OMU self-healing
Whether to enable the board parameters to be configured. If this parameter is
set to "YES", the user can set board parameters of the BTS. Otherwise, the user
cannot set the board parameters.
Whether to enable the 3ah function on the BTS port.
The field indicates whether the primary path can be switched back when it is
available.
The association is smoothly switched over to the primary path after the number
of heartbeat responses is received.
Set patch switch parameter1

Set patch switch parameter10

Set patch switch parameter2

Set patch switch parameter3

Set patch switch parameter4

Set patch switch parameter5

Set patch switch parameter6

Set patch switch parameter7

Set patch switch parameter8

Set patch switch parameter9


Number of the switching port. If "Link Attribute" is set to "BBU", the switching
port must be configured. The value ranges from 3 to 5.
Whether to enable the local user management function

Sequence of the start week of DST


Symbol offset of the BTS set manually. After the offset information of the BTS is
collected, the symbol offset is adjusted. Adjustment value = Collected symbol
offset relative to the reference BTS - (BTS symbol offset + BSC symbol offset).
Synchronization status. This parameter is used to identify different 3G cells.
This parameter should be same with the configuration of 3G cells.
Site synchronization method. AISS stands for the air-interface soft
synchronization method, and GPS stands for the GPS synchronization method.
Synchronization mode of the IP clock
Interim synchronization period (in days). The BTS can re-initiate the
synchronization only after the period.
Interim synchronization period (in hours). The BTS can re-initiate the
synchronization only after the period.
Interim synchronization period (in minutes). The BTS can re-initiate the
synchronization only after the period.
Contact way of the Base Station Controller supplier

Description of the Base Station Controller

System flux thresholds correspond to the system flux obtained based on


message packets, CPU load, and FID queuing load. The system flux level is the
current flux control level of the system.
0-11: There are 12 flow control levels. Where, 0 indicates the lowest level and
11 indicates the highest level.
A load handover is allowed only when the system flux is lower than the value of
this parameter. The handover performed over the maximum threshold may
have tremendous impacts on the system. Thus, this parameter should not be
set to a higher value. 1) The flow control level algorithm for the assigned
system messages: [(Average Message Usage - Inner Flow Control Discard Begin
Threshold)/(Inner Flow Control Discard All Threshold - Inner Flow Control Discard
Begin Threshold) x 100]/10+1 (round-down for division operation). If the value
is smaller than Inner Flow Control Discard Begin Threshold, Level 0 is used. If
the value is equal to or greater than Inner Flow Control Discard Begin
Threshold, the level is calculated. The value range is from 0 to 11.
2) Flow control threshold for the CPU to start to discard the channel access
messages and paging messages: 80%
. Flow control threshold for the CPU to discard all channel access messages and
paging messages: 100%
. CPU usage smaller than 80% corresponds to level 0. CPU usage equal to or
greater than CPU flow control threshold 80% corresponds to level 2. An increase
of 5% means an increase of 2 levels. Level 10 is the highest. The level value
can be 0, 2, 4, 6, 8, and 10.

Location of the Base Station Controller


Whether sending the system information type 10 message on the VGCS/VBS
TCH is allowed. For detailed information, see the 3GPP TS 44.018 9.1.50.
Name of the Base Station Controller of Network Element

Services provided by the Base Station Controller

Value of the first timer for the PTU handshake


Timer T1, specifying the duration of monitoring the BVC blocking (unblocking)
procedure.

When the reception of a TFP causes unavailability of a route, this timer is


started to regularly check whether the route is recovered.
This timer is a protection timer waiting for an uninhibit acknowledgement
message (LUA) from the peer end after an uninhibit message (LUN) is sent to
the peer end.
This timer is a protection timer waiting for a force uninhibit acknowledgement
message (LUA) from the peer end after a force uninhibit message (LFU) is sent
to the peer end.
This timer is a protection timer waiting for an inhibition acknowledgement
message (LIA) from the peer end after an inhibition message (LIN) is sent to the
peer end.
This timer is started when a link fails to be started. The restart of the link is
initiated after this timer expires.
When a normal changeover cannot be initiated, services will be changed over
to an alternative link after this timer expires to avoid disorder of data.
Value of the second timer for the PTU handshake
Timer T2, specifying the duration of monitoring the procedure of resetting SIG
BVC and PTP BVC.

Timer in the LAPD protocol. The value of the timer indicates the time when the
LAPD link waits for the response or acknowledgement frame after sending the
command frame.

This parameter specifies the expiry value of timer T200 used for the
FACCH/TCHF over the Um interface. For the function of timer T200 and the
effect of the parameter, see the description of "T200 SDCCH".

This parameter specifies the expiry value of timer T200 used for the
FACCH/TCHH over the Um interface. For the function of timer T200 and the
effect of the parameter, see the description of "T200 SDCCH".

This parameter specifies the expiry value of timer T200 used for the SACCH
over the Um interface when the TCH supports SAPI3 services. For the function
of timer T200 and the effect of the parameter, see the description of "T200
SDCCH".

This parameter specifies the expiry value of timer T200 used for the SACCH on
the SDCCH.
For the function of timer T200 and the effect of the parameter, see the
description of "T200 SDCCH".

This parameter specifies the expiry value of timer T200 used for the SACCH
over the Um interface when the TCH supports SAPI0 services. For the function
of timer T200 and the effect of the parameter, see the description of "T200
SDCCH".

This parameter specifies the timeout value of timer T200 used for the SDCCH
over the Um interface.
T200 prevents the data link layer from deadlock during data transmission. The
data link layer transforms the physical link that is vulnerable to errors into a
sequential non-error data link. The entities at the two ends of this data link use
the acknowledgement retransmission mechanism.
Each message must be confirmed by the peer end. In unknown cases, both
ends are waiting if a message is lost. At this time, the deadlock of the system
occurs. Therefore, the transmit end must establish a timer. When the timer
expires, the transmit end regards that the receive end does not receive the
message and then the transmit end retransmits the message. The number of
retransmissions is determined by N200. T200 and the N200 ensure that the
data link layer sequentially transmits data and that the transmission is free
from errors.

This parameter specifies the expiry value of timer T200 when the SDCCH
supports SAPI3 services.
For the function of timer T200 and the effect of the parameter, see the
description of "T200 SDCCH".

Timer in the LAPD protocol. The value of the timer indicates the maximum
duration for no frame exchange in the LAPD link.

After a local link is inhibited, this timer is started to regularly check the
management states at both ends of the link.
After a remote link is inhibited, this timer is started to regularly check the
management states at both ends of the link.
This timer is a protection timer waiting for an extended changeover
acknowledgement message (XCA) from the peer end after an extended
changeover order message (XCO) is sent to the peer end.
Value of the third timer for the PTU handshake
Timer T3. T3 is started after the message SUSPEND is received on the BSC side.
T3 is stopped after the message SUSPEND ACK is received.
When the BTS sends physical information to the MS, the BTS starts the timer
T3105.If the timer T3105 expires before the BTS receives the SAMB frame from
MS, the BTS resends physical information to the MS and restarts the timer
T3105. The maximum times for resending physical information is "Max Resend
Times of Phy.Info.". For details, see GSM Rec. 04.08 and 08.58.

Timer for retransmitting the VGCS UPLINK GRANT message

T3168 is used to set the maximum duration for the MS to wait for the uplink
assignment message. After the MS originates the uplink TBF setup request by
sending the packet resource request or the channel request in the packet
uplink acknowledge message, the timer T3168 is started to wait for the packet
uplink assignment message on the network side. If the MS receives the packet
uplink assignment message before T3168 expires, T3168 is reset. Otherwise,
the MS originates the packet access request for four times. Then the MS
regards this as the TBF setup failure.

Duration of releasing the TBF after the MS receives the last data block. When
the MS receives the RLC data block containing the flag identifying the last data
block and confirms that all the RLC data blocks in the TBF are received, the MS
sends the packet downlink acknowledge message containing the last flag
acknowledgement and the timer T3192 is started. If the timer T3192 expires,
the MS releases the TBF related resources and starts monitoring the paging
channel. During TBF releasing, if the MS is the half duplex mode and receives
the packet uplink assignment, the MS responds this command. During TBF
releasing, if the MS is the half duplex mode and receives no packet uplink
assignment message, the MS enters the packet idle mode. If the MS is in the
dual transmission mode, the MS enters the special mode.

This parameter specifies the length of the timer for periodic location update.

Timer on the DTE side, specifying the duration of acknowledging the sending
BC link integrity.

When a normal changeback cannot be initiated, services will be changed back


to a normal link only after this timer expires to avoid disorder of data.
Timer T4. T3 is started after the message v is received on the BSC side. T4 is
stopped after the message RESUME ACK is received.
This timer is a protection timer waiting for a changeback acknowledgement
message (CBA) from the peer end after the first changeback declaration (CBD)
is sent to the peer end.
Timer T5. When the downlink TBF is set up, if the BSC side does not receive the
valid RACAP, the BSC originates the radio access capability update flow and the
timer T5 is started. After receiving the core network response, the timer is
stopped.
This timer is a protection timer waiting for a changeback acknowledgement
message (CBA) from the peer end after the second changeback declaration
(CBD) is sent to the peer end.
Timer T6. The BSC sends the SGSN request to download the BSS PFC. When the
QoS parameter is obtained, the timer is started. After the message
CREATE_BSS_PFC is received, the timer is stopped. After the timer expires, the
request is sent to start the procedure of downloading the BSS PFC.
Timer T8. The BSC sends the SGSN request to download the BSS PFC. When the
QoS parameter is obtained, the timer is started. After the message
MODIFY_BSS_PFC_ACK is received, the timer is stopped. After the timer expires,
the request is sent to start the procedure of downloading the BSS PFC.
This timer is started when a transmission prohibited message (TFP) is sent. The
TFP will not be sent any more during the running of this timer.
When the network receives measurement reports, the measurement values in
several straight measurement reports are filtered to reflect the radio operating
environment for the sake of accuracy. This parameter specifies the number of
measurement reports sampled for filtering the TA.

Whether the TA is used as a decisive condition for the concentric cell handover

Whether to enable the time advance (TA) handover. The TA handover


determines whether the timing advance (TA) is higher than the predefined TA
threshold. When the TA is higher than the predefined TA threshold, a TA
handover is triggered. The TA is calculated based on the distance between the
MS and the BTS. The longer the distance is, the greater the TA value is.

One of the parameters that determine the coverage of the OL subcell and UL
subcell.
When "Enhanced Concentric Allowed" is set to OFF, "TA Hysteresis", "RX_LEV
Threshold", "RX_LEV Hysteresis", "RX_QUAL Threshold", and "TA Threshold"
determine the coverage of the OL subcell and UL subcell.
When "Enhanced Concentric Allowed" is set to ON, "TA Hysteresis", "UtoO HO
Received Level Threshold", "OtoU HO Received Level Threshold", "RX_QUAL
Threshold", and "TA Threshold" determine the coverage of the OL subcell and
UL subcell.

The P/N criterion must be met for triggering a TA handover. That is, the TA
handover can be triggered only if P measurement reports among N
measurement reports meet the triggering conditions. This parameter
corresponds to P in the P/N criterion.

An emergency handover is triggered when TA is greater than or equal to the


value of this parameter.

This parameter specifies the interval of broadcasting the speech data of the
talker on the downlink group call channel that is controlled by the BTS. When
the parameter is set to 0, the BTS (instead of the BSC6900) performs the
broadcasting with the default interval 5s.
When the network receives measurement reports, the measurement values in
several straight measurement reports are filtered to reflect the radio operating
environment for the sake of accuracy. This parameter specifies the number of
measurement reports sampled for filtering the TA on the signaling channel.

Unique identifier of the Um interface software synchronization task

The P/N criterion must be met for triggering a TA handover. That is, the TA
handover can be triggered only if P measurement reports among N
measurement reports meet the triggering conditions. This parameter
corresponds to N in the P/N criterion.

One of the parameters that determine the coverage of the OL subcell and UL
subcell.
When "Enhanced Concentric Allowed" is set to OFF, "TA Hysteresis", "RX_LEV
Threshold", "RX_LEV Hysteresis", "RX_QUAL Threshold", and "TA Threshold"
determine the coverage of the OL subcell and UL subcell.
When "Enhanced Concentric Allowed" is set to ON, "TA Hysteresis", "UtoO HO
Received Level Threshold", "OtoU HO Received Level Threshold", "RX_QUAL
Threshold", and "TA Threshold" determine the coverage of the OL subcell and
UL subcell.

Filter period of the signal strength in the packet transmission mode of the MS.
The MS in the packet transmission mode measures the downlink signal
strength. This parameter is used to calculate the Cn value of the MS output
power. This parameter specifies the relation between Cn and Cn-1.
Filter period of the signal strength in the packet idle mode of the MS. The MS in
the packet idle mode measures the downlink signal strength. This parameter is
used to calculate the Cn value of the MS output power. This parameter specifies
the relation between Cn and Cn-1.

Number of the output segment


1: Segment 1 describes the basic information of the equipment.
2: Segment 2 describes the connection information.
3: Segment 3 describes the module information.
4: Segment 4 describes the configuration information.
5: Segment 5 describes the information of the peer equipment.
6: Segment 6 describes the version information of the host.
7: Segment 7 describes the cabinet information.
8: Segment 8 describes the subrack information.
9: Segment 9 describes the board information and electronic label information
of the Flash.
10: Segment 10 describes the slot information.
11: Segment 11 describes the port information.
12: Segment 12 describes the antenna information.

Output Segment No.


1: Segment 1 describes the basic information of the equipment.
2: Segment 2 describes the connection information.
3: Segment 3 describes the module information.
4: Segment 4 describes the configuration information.
5: Segment 5 describes the information of the peer equipment.
6: Segment 6 describes the version information of the host.
7: Segment 7 describes the cabinet information.
8: Segment 8 describes the subrack information.
9: Segment 9 describes the board information and electronic label information
of the Flash.
10: Segment 10 describes the slot information.
11: Segment 11 describes the port information.
12: Segment 12 describes the antenna information.
Maximum time in which the BTS attempts to set up the OML after swapping the
main and backup OMLs. If the BTS fails to set up the OML within this time, the
BTS swaps the main and backup OMLs again.

The BTS repeatedly attempts to connect to port 0 or port 1 after the switchover.
If the connection on one port fails within the time specified by this parameter,
the BTS tries to connect to another port.

Test code for the MTP3 link. After the successful test, the link can be used for
carrying signaling services. If the test fails, the MTP3 periodically sends the
fault locating command until the operation is successful. When the link is
deleted or deactivated, the system stops to send the fault locating command.
The default value is 170.

Timer Tc, specifying the interval for the BVC and MS to send flow control
messages. When this parameter is set to a smaller value, the BVC and the MS
send flow control messages in a shorter time, which allows the SGSN can use
the latest flow control parameter to improve the transmission performance.
When the BVC and MS send flow control messages, certain bandwidth is
required. If this parameter is set to a too small value, the transmission
performance is reduced. If this parameter is set to a greater value, the realtime
flow control mechanism of the Gb interface cannot handle the current situation
properly. This can reduce the transmission performance and provide more
bandwidth.

Temperature compensation coefficient. This parameter defines the charging


voltage increase or decrease unit of each battery when the ambient
temperature of the battery varies with the reference temperature regulated by
the vendor by 1 degree Celsius. See the vendor specification for the setting of
this parameter.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

This parameter specifies the cyclic redundancy check (CRC) switch, which can
be set to On or Off. The value of this parameter determines whether check is
performed on the TRAU frame between the BSC6900 and the BTS.

Whether to allow the cell to dynamically change a channel from full rate to half
rate or from half rate to full rate. If this parameter is set to YES, the conversion
is allowed; if the parameter is set to NO, the conversion is not allowed and the
changed channel is restored to the previous rate mode. In addition, this
parameter helps to determine the channel assignment priority. The channels in
a TRX that does not allow dynamic adjustment take priority.

If the current channel seizure ratio reaches or exceeds this value, the half-rate
TCH is assigned preferentially; otherwise, the full-rate TCH is assigned
preferentially.

When a call drops on the TCH, the corresponding TCH call drop counter is
incremented by one if the DL FER carried in the last MR is greater than the
value of this parameter.

When a call drops on the TCH, the corresponding TCH call drop counter is
incremented by one if the downlink level carried in the last MR is lower than the
value of this parameter.

When a call drops on the TCH, the corresponding TCH call drop counter is
incremented by one if the downlink quality carried in the last MR is greater than
the value of this parameter.

When a call drops on the TCH, the corresponding TCH call drop counter is
incremented by one if the UL FER carried in the last MR is greater than the
value of this parameter.

When a call drops on the TCH, the corresponding TCH call drop counter is
incremented by one if the uplink level carried in the last MR is lower than the
value of this parameter.

When a call drops on the TCH, the corresponding TCH call drop counter is
incremented by one if the uplink quality carried in the last MR is greater than
the value of this parameter.

After a new TCH is assigned to an MS, the MS can be handed over to another
channel only if the time during which the MS occupies the TCH is longer than
the period specified by this parameter.

Maximum number of discarded MRs allowed on the TCH in a power control


period

Whether the TCH rate type uses the MSC strategy or BSC strategy. When this
parameter is set to NO and the MSC policy is used, the BSC preferentially
selects full-rate or half-rate channels based on the rate type carried by the MSC
in the assignment or incoming BSC handover request. When this parameter is
set to YES and the BSC policy is used, the BSC preferentially selects full-rate or
half-rate channels based on the internal load.
This parameter specifies the interval at which the speech service on a TCH is
handed over.
This parameter specifies whether to perform periodic intra-cell handover for
speech services on TCH.

Threshold for determining that the underlaid subcell is busy. The BSC assigns
channels in the underlaid subcell to the MS in a concentric cell. When "Allow
Rate Selection Based on Overlaid/Underlaid Subcell Load" is set to YES, halfrate channels are assigned if the channel seizure ratio in the underlaid subcell
exceeds the value of this parameter, and full-rate channels are assigned if the
channel seizure ratio in the underlaid subcell does not exceed the value of this
parameter.

The BSC assigns channels in the overlaid subcell to the MS in a concentric cell.
If the channel seizure ratio of overlaid subcell is greater than the value of this
parameter, half-rate channels are assigned. Otherwise, full-rate channels are
assigned.
Channel seizure ratio = (Num. of busy TCHF + Num. of busy TCHH/2)/(Num. of
available TCHF + Num. of available TCHH /2) x 100%. This parameter is valid
for the concentric cell. When the "Allow Rate Selection Based on
Overlaid/Underlaid Subcell Load" is set to Yes, the "TCH Traffic Busy Threshold
(%)" is invalid for the concentric cell.

Test code length of the signaling link. By default, the value is 10.
Mode of TC.
SEPERATE_PRINCIPAL: Specifies that the MTP3 link is configured for the primary
BSC in the case of BM/TC separated configuration mode.
SEPERATE_SUBORDINATE: Specifies that the MTP3 link is configured for the
slave BSC in the case of BM/TC separated configuration mode.
TOGETHER: Specifies that the MTP3 link is configured in the case of BM/TC
combined configuration mode.
SEPERATE_BSC_INTERFACE: Specifies that the MTP3 link is configured for the
primary BSC in the case of BM/TC separated configuration mode and that the
MTP3 link is carried on the Ater interface board.
Whether to enable the class-1 mute detection.

Number of the cabinet where the main board of the RXU ring is located

Number of the TC port where one end of the ATER connection channel is
located
If you enable the TC pool function when configuring the basic information of the
BSC6900, you need to enter the TC Pool ID. The ID must be unique in the entire
network.
Number of the TC slot where one end of the ATER connection channel is located
Number of the TC subrack where one end of the ATER connection channel is
located
The type of TC resource
GTC: TC resources that support normal voice coding/decoding and packet
conversion
UTC: TC resources that support only the optimized handover on the Iur-g
interface
ITC: TC resources that support only the dual-stack function on the A interface
Input mode of the BA table. In auto mode, the system fills in the BA1 and BA2
tables based on the adjacent relation of cells. In manual mode, the user
maintains the BA table. If the adjacent relation of cells is modified, for example,
a neighboring cell is added or a cell is deleted, the user needs to maintain the
BA1 and BA2 tables.
Whether the FDD BA2 table is generated automatically according to the
neighboring relation or typed manually.

When the priority of a TDD cell is ranked, the value of this parameter is added
to the receive level of the TDD cell in the measurement report.
The values of this parameter correspond to the following decibel values:
0: 0 dB
1: 6 dB
...
7: 42 dB

A TDD cell can become a candidate cell only when the average receive level of
the TDD cell is greater than the TDD Cell Reselect Diversity of the serving cell.
The value of this parameter corresponds to the following decibel value:
0: negative infinity
1: -28 dB
2: -24 dB
...
15: 28 dB

Threshold for determining whether the MR about a TDD cell is valid.


The measurement report is valid if the receive level of the TDD cell in the
measurement report is greater than the value of this parameter. After the valid
measurement report is filtered, the TDD cell joins in the cell prioritization.
The value of this parameter corresponds to the following decibel value:
0: 0 dB
1: 6 dB
...
6: 36 dB
7: positive infinity

This parameter specifies whether to activate the diversity mode on the


common channel of a 3G cell.
Downlink frequency of frequency 1 in table 3GBA2. This parameter indicates
the detected downlink frequency in the 3G adjacent cell list in speech. The
parameter is delivered in the system information 2QUTER/MI.
This parameter specifies whether the TDD MI system information optimized
function is enabled. When this parameter is set to NO and "TDD System
Information Optimized Allowed" is set to YES, the MI system information issued
in the TDD scenario does not carry neighboring cell scrambling codes. In other
scenarios, the MI system information carries neighboring cell scrambling codes.
This parameter specifies whether to send the system information MI which
contains the 3G neighboring cell information in the TDD neighboring cell. The
value YES(YES) indicates that the MI is sent, and the value NO(NO) indicates
that the MI is not sent.
Minimum RSCP quality threshold that the TDD 3G candidate cell must reach

Cell parameter ID of a TDD cell. The cell parameter ID distinguishes between


MSs or cells. It is used after spread spectrum. Therefore, it distinguishes
between the signals from different sources, but not the changes in the
bandwidth of signals. Through scrambling, multiple transceivers can use the
same codes for spread spectrum.
TDD cell parameter ID. The ID is used to distinguish terminals or cells. This
parameter is used after spread spectrum. Therefore, it does not change the
bandwidth of signals, but only distinguishes the signals from different sources.
Through scrambling, multiple transceivers can use the same codes for spread
spectrum.
This parameter specifies whether to optimize the system information 2Quater
and MI of the TDD neighboring cell. That is, to add an FDD neighboring cell
information before the TDD neighboring cell information to solve the
compatibility problem of some dual-mode MSs.

SyncCase in the TDDBA1 table. This parameter determines the synchronization


status. Value 0 indicates Sync case 1 and value 1 indicates Sync case 2. This
parameter is used to identify different 3G cells.

If the ratio of available TDM bandwidth is greater than this value, congestion
control is stopped.
If the ratio of available TDM bandwidth is less than or equal to this value,
congestion control is triggered.
Each subrack has six TDM port numbers, ranging from 0 to 5. Subrack 1 TDM
Port No. refers to the TDM port number on subrack 1 of the inter-subrack
connection..
Each subrack has six TDM numbers, ranging from 0 to 5. Subrack 2 TDM Port
No. refers to the TDM number on subrack 2 of the inter-subrack connection.

Terminal endpoint ID of the Pb signaling link

Temperature alarm switch

Upper limit of temperature

Lower limit of temperature

When the environment temperature of the APMU is greater than the value of
this parameter, the BTS reports an alarm. For the APMU of the non-EPS4815
type, the minimum value of the parameter is -490.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
When the environment temperature is greater than the value of this parameter,
the BTS reports an alarm.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
When the environment temperature of the APMU is less than the value of this
parameter, the BTS reports an alarm. For the APMU of the non-EPS4815 type,
the maximum value of the parameter is 990.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
When the environment temperature is less than the value of this parameter,
the BTS reports an alarm.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Change value of the floating charge voltage of the storage battery when the
temperature of the storage battery changes by 1 degree Celsius.
Description of a cell template.
This parameter specifies the index number of a cell template. Each template is
numbered uniquely in a BSC6900.
This parameter specifies the index number of a cell template. Each template is
numbered uniquely in a BSC6900.

Name of a cell template, uniquely identifying a cell template in a BSC6900.

When the temperature of the BTS cabinet is greater than the value of this
parameter, the TRX is powered off.

TRX power-off temperature threshold. If the temperature of the BTS cabinet is


less than the value of this parameter while "Low Temperature Startup Allowed"
is set to "Yes", the TRX is powered off.

TRX power-off temperature threshold. If the temperature of the BTS cabinet is


less than the value of this parameter while "Low Temperature Startup Allowed"
is set to "Yes", the TRX is powered off.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Whether the System Information Type 3 message carries TER indication.

Duration of the timer for starting the IP path status test on the Gb interface

Content of the cell broadcast message

AEC is an important measure to improve the speech quality. If the AEC works
for a consecutive time that is longer than the value of this parameter, the TFO
function is closed to provide a better speech quality.

In the VSWR test, the TRX transmits signals at a default frequency. You can
specify the frequency used for the test.
This parameter indicates start frame number of the BTS. It is used to keep
synchronization between the BTS and MS after the BTS is re-initialized.
Target OMU

TGW ID

This parameter indicates the address of the operation and maintenance console
for TGW.

This parameter indicates the mask of the operation and maintenance console
for TGW.

Slot number of the BSC6900 interface board interworking with TGW.

Subrack number of the BSC6900 interface board interworking with TGW.

Timer Th. After receiving the MS flow control message, the SGSN uses the
values of the updated Bmax and R based on the interval set by this timer.
When this parameter is set to a smaller value, the SGSN can use the flow
control parameter in a shorter time. In this way, the data can be transferred
according to the most suitable flow control parameters, which can improve the
transmission performance. When this parameter is set to a greater value, the
SGSN uses the flow control parameter in a longer time.
Voltage threshold for switching off the air conditioner. If the power supply
voltage is less than this threshold, the air conditioner needs to be switched off
to decrease the impact on the BTS.
Voltage threshold for switching on the air conditioner. This parameter assumes
that the air conditioner is switched off. If the power supply voltage is greater
than this threshold, the air conditioner needs to be switched on to ensure that
the BTS runs properly.

Combination of the THP1 and ARP1 priority in the Interactive service. THP1ARP1 priority weight determines the number of the budget blocks and the block
scheduling priority.
Combination of the THP1 and ARP2 priority in the Interactive service. THP1ARP2 priority weight determines the number of the budget blocks and the block
scheduling priority.
Combination of the THP1 and ARP3 priority in the Interactive service. THP1ARP3 priority weight determines the number of the budget blocks and the block
scheduling priority.
Combination of the THP2 and ARP1 priority in the Interactive service. THP2ARP1 priority weight determines the number of the budget blocks and the block
scheduling priority.
Combination of the THP2 and ARP2 priority in the Interactive service. THP2ARP2 priority weight determines the number of the budget blocks and the block
scheduling priority.
Combination of the THP2 and ARP3 priority in the Interactive service. THP2ARP3 priority weight determines the number of the budget blocks and the block
scheduling priority.
Combination of the THP3 and ARP1 priority in the Interactive service. THP3ARP1 priority weight determines the number of the budget blocks and the block
scheduling priority.
Combination of the THP3 and ARP2 priority in the Interactive service. THP3ARP2 priority weight determines the number of the budget blocks and the block
scheduling priority.
Combination of the THP3 and ARP3 priority in the Interactive service. THP3ARP3 priority weight determines the number of the budget blocks and the block
scheduling priority.
Load balance threshold type. It indicates the threshold calculation mode.
This parameter specifies the timer set to wait for a private message from the
SGSN.

During channel assignment, the assignment of channels on the BCCH TRXs


depends on the uplink receive level, quality, and non-BCCH load. The TCHs are
preferentially assigned on the BCCH TRXs if the following conditions are met:
1. The uplink receive level after filtering is higher than "Level Thresh. for
Assigning Main BCCH Carrier Channel Under TIGHT BCCH".
2. The uplink receive quality level after filtering is lower than "Quality Thresh.
for Assigning Main BCCH Carrier Channel Under TIGHT BCCH".
3. The non-BCCH load is higher than "Intracell Non Main BCCH Load Threshold
of TIGHT BCCH".

During channel assignment, the assignment of channels on the BCCH TRXs


depends on the uplink receive level, quality, and non-BCCH load. The TCHs are
preferentially assigned on the BCCH TRXs if the following conditions are met:
1. The uplink receive level after filtering is higher than "Level Thresh. for
Assigning Main BCCH Carrier Channel Under TIGHT BCCH".
2. The uplink receive quality level after filtering is lower than "Quality Thresh.
for Assigning Main BCCH Carrier Channel Under TIGHT BCCH".
3. The non-BCCH load is higher than "Intracell Non Main BCCH Load Threshold
of TIGHT BCCH".

The P/N criterion must be met for triggering a TIGHT BCCH handover. That is,
the TIGHT BCCH handover can be triggered only if P seconds among N seconds
meet the triggering conditions. This parameter corresponds to P in the P/N
criterion.

During channel assignment, the assignment of channels on the BCCH TRXs


depends on the uplink receive level, quality, and non-BCCH load. The TCHs are
preferentially assigned on the BCCH TRXs if the following conditions are met:
1. The uplink receive level after filtering is higher than "Level Thresh. for
Assigning Main BCCH Carrier Channel Under TIGHT BCCH".
2. The uplink receive quality level after filtering is lower than "Quality Thresh.
for Assigning Main BCCH Carrier Channel Under TIGHT BCCH".
3. The non-BCCH load is higher than "Intracell Non Main BCCH Load Threshold
of TIGHT BCCH".

The P/N criterion must be met for triggering a TIGHTBCCH handover. That is,
the TIGHTBCCH handover can be triggered only if P seconds among N seconds
meet the triggering conditions. This parameter corresponds to N in the P/N
criterion.

When an intra-cell TIGHT BCCH handover needs to be performed (handover


from the non-BCCH to BCCH), the downlink receive quality must be smaller
than the value of this parameter.
Whether to enable the BCCH aggressive frequency reuse algorithm

If the SDCCH load on the TRXs of the compatible BCCH in loose frequency reuse
pattern is greater than the "IBCA Loose Trx SDCCH Load Threshold", and when
the uplink receive level from the MS to the BTS is greater than the threshold,
the SDCCHs on the TRXs of the compatible non-BCCH are preferentially
assigned. Otherwise, the SDCCHs on the TRXs of the compatible BCCH are
preferentially assigned.

IMSI paging timer. After enabling the MSC pool function, the BSC6900 receives
from the MSC the paging message attached with the IMSI. Then, the BSC6900
records the relation between the IMSI and the MSC SP and starts the timer with
predefined length.
If the BSC6900 receives a response message with the IMSI before the timer
expires, the BSC6900 locates the destination MSC based on the IMSI and MSC
SP, and routes the current paging to the MSC.
If the BSC does not receive a response when the timer expires, the BSC6900
clears the relation information between the IMSI and MSC SP.

Duration of frequency scanning

Time

Whether to limit the operation time of the operator

Within the preset time, no AMR FR-to-HR handover is allowed if the previous FRto-HR handover fails due to channel unavailability or channel mismatch.

After a handover due to bad quality is successful, the penalty on the original
serving cell is performed within the "Penalty Time after BQ HO": the receive
level of the original serving cell is decreased by "Penalty Level after BQ HO", to
prevent ping-pong handovers.

After an OL subcell to UL subcell handover of an MS fails, the MS does not


perform OL subell-UL subcell handovers within the value of the parameter.

Longest waiting time for multiplexing


When the multiplexed packet is no longer added with new data and the timer
expires, the multiplexed packet is transmitted directly.
This parameter is determined by the number of multiplexed packets. When the
number of multiplexed packets increases, the value of this parameter
increases.
Indicates the timeout time of the PING packet
Timeout time for waiting for the TRACERT packet response
Timeout time
Indicates the timeout time of the CFM link tracing detection

After the fast handover is successful, the penalty on the original serving cell is
performed within the "Quick handover punish time": the receive level of the
original serving cell is decreased by "Quick handover punish value", to prevent
ping-pong handovers.

Indicates the times of sending PING packets


This parameter determines whether the dynamic voltage adjustment function is
enabled on the basis of the number of timeslots. If this parameter is set to YES,
the power consumption of base stations is reduced. This parameter maps the
versions of base stations. If the parameter is set to NULL, base stations do not
support this function.

After the time advancing handover is successful, the penalty on the original
serving cell is performed within the "Penalty Time after TA HO": the receive
level of the original serving cell is decreased by "Penalty Level after TA HO", to
prevent ping-pong handovers.

After an UL subcell to OL subcell handover of an MS fails, the MS does not


perform UL subcell to OL subcell handovers within the value of the parameter.

This parameter indicates the queue timer for assignment.


When the BSC6900 receives an assignment request and no channel is available
for assignment, the BSC6900 starts the queuing procedure and the timer. If the
channel request is successful before the timer expires, the timer stops. If the
timer expires, the channel assignment fails.
If the BSC6900 receives the configuration data about all the connected MSCs
before the timer expires, the BSC6900 concludes that the configuration data is
valid.
When the operation time of the OMU exceeds the value specified by this
parameter, some records are deleted from the operation log.

Temporary logical link ID in the decimal format

Lowest expected value of the air outlet temperature.


In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Temperature alarm lower threshold. If the temperature of the battery is lower
than the value of this parameter, an alarm indicating the abnormal temperature
is reported.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
When the internal temperature of the BTS reaches the Temperature Alarm
Lower Threshold, it reports a low temperature alarm.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

When the time mode is set to "ONTIME", you should set this parameter.
If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should
set this parameter. This parameter specifies the first execution time in the day
in which the scheduled task is executed.
If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should
set this parameter. This parameter specifies the second execution time in the
day in which the scheduled task is executed.
If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should
set this parameter. This parameter specifies the third execution time in the day
in which the scheduled task is executed.

If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should


set this parameter. This parameter specifies the fourth execution time in the
day in which the scheduled task is executed.
If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should
set this parameter. This parameter specifies the fifth execution time in the day
in which the scheduled task is executed.
TRMMAP index
Index of the traffic mapping used by the current adjacent node's gold user.

Loopback time length

Test mode

Duration time for determining that a call is hung up because of poor quality. If
the uplink quality or downlink quality in the measurement reports during the
period of Timer for "Bad Quality DISC Statistic" is higher than the value of "Bad
Quality Disconnection Threshold" before the call is disconnected, you can infer
that the call disconnection is due to poor quality. This parameter can be used to
calculate the number of call disconnections due to poor quality.

Maximum rate of the accumulated alarm blink duration to the alarm blink
measurement period. Assume this threshold is not 0. When the rate of
accumulated alarm blink duration exceeds the threshold, an alarm is reported.
For querying the alarm blink measurement period, see "LST ALMBLKSW". For
setting the alarm blink measurement period, see "SET ALMBLKSW".

TMSI of the MS

Minimum rate of the accumulated alarm blink duration to the alarm blink
measurement period. Assume this threshold is not 0. When the rate of
accumulated alarm blink duration is lower than the threshold, an alarm is
reported. For querying the alarm blink measurement period, see "LST
ALMBLKSW". For setting the alarm blink measurement period, see "SET
ALMBLKSW".

This timer is a protection timer waiting for a signalling link test


acknowledgement message (SLTA) from the peer end after a signalling link test
message (SLTM) is sent to the peer end.
This timer is used to send the signalling link test messages (SLTM) to the peer
end regularly.

Name of the data table distributed on the board.

E1 transmission type of the Pb interface. The terrestrial transmission or satellite


transmission can be selected. In the areas such as desert and lake where the
terrestrial transmission is difficult, the satellite transmission can be used.
The Ater signaling link operates in the terrestrial transmission or satellite
transmission mode. In the areas such as desert and lake where the terrestrial
transmission is difficult, the satellite transmission can be used.
Cell Reselect Temporary Offset (TO) indicates the temporary correction of C2.
This parameter is valid only within the value specified by "Cell Reselect Penalty
Time". For details, see GSM Rec. 05.08 and 04.08. This parameter applies to
only GSM Phase II MSs.
Offset to DST, namely, the adjustment to time.

Number of the cabinet where the board is located

Number of the slot where the board is located

Number of the subrack where the board is located

Type of the host log to be collected.


If this parameter is set to NORMAL, the text log in the \common\fam\famlog
directory of the OMU installation path is collected and saved in the
\common\fam\famlog directory of the OMU installation path.
If this parameter is set to FORMAT, the binary log in the
\common\fam\famlogfmt directory of the OMU installation path is collected and
saved in the \common\fam\famlogfmt directory of the OMU installation path.

Number of the optical port where the main board of the RXU ring is located.

Length of the timer that is started to wait for a channel requested by an


incoming BSC handover request message.
When the MSC allows the queuing of incoming BSC handover requests, the
BSC6900 starts the queuing procedure and the timer if no channel is available
for assignment. If the channel request is successful before the timer expires,
the timer stops. If the timer expires, the incoming BSC handover fails.
CPU usage threshold for debugging tracing flow control. When the average CPU
usage of sliding windows reaches or exceeds the threshold, debugging tracing
flow control is triggered.
Packet queue usage threshold for debugging tracing flow control. When the
average packet queue usage of sliding windows reaches or exceeds the
threshold, debugging tracing flow control is triggered.
CPU usage threshold for recovery from debugging tracing flow control. When
the average CPU usage of smooth windows is lower than the threshold,
debugging tracing flow control is stopped.
Packet queue usage threshold for recovery from debugging tracing flow control.
When the average packet queue usage of smooth windows is lower than the
threshold, debugging tracing flow control is stopped.
Whether to control the debugging tracing flow
Threshold for determining whether the uplink service is preferred. Within the
"Flux Measurement Period", if the ratio of the downlink LLC PDU flux and uplink
LLC PDU flux is higher than the threshold, the service type of the MS is uplink
preferred.
Threshold for determining whether the uplink service is preferred. Within the
"Flux Measurement Period", if the ratio of the uplink LLC PDU flux and downlink
LLC PDU flux is higher than the threshold, the service type of the MS is uplink
preferred.
Traffic mode of the M3UA link set. At present, only the active/standby and load
sharing mode is available.
If the M3UA links in the link set work in overriding mode, only one link in the
link set works in the active mode, and all other links work in the standby mode.
In this case, only the active link carries traffic, and the standby links do not
carry any traffic. When the active link is faulty, the standby link with the
highest priority is automatically activated to take over as the active link.
If the M3UA links in the link set work in load-sharing mode, all the M3UA links in
the link set work in active mode and carry traffic.

This parameter specifies the data transmission mode between the BTS and the
BSC6900. The license control modes are different in different transmission
modes.
Terrestrial Transmission: The data between the BTS and the BSC6900 is
transmitted through the E1 or fiber. This transmission mode has a short delay
and is not controlled by the license.
Satellite Transmission: The data between the BTS and the BSC6900 is
transmitted through the satellite. This transmission mode has a long delay and
is controlled by the license.
Terrestrial and Satellite: In normal cases, the terrestrial transmission mode is
used. When the terrestrial transmission is faulty, the satellite transmission
mode is used. This transmission mode is controlled by the license.

Slot number of the transparently transmitting interface board


Transport type of the adjacent node to which the path belongs.

Transport type

Transport type

Transmission Type

Transmission type of the BTS


Whether to configure the optical transmission mode for E1 port 0 of the
BTS3006C/BTS3002E. If the optical transmission mode is configured, the
BSC6900 can connect to the BTS through optical fibers.
Whether to configure the optical transmission mode for E1 port 1 of the
BTS3006C/BTS3002E. If the optical transmission mode is configured, the
BSC6900 can connect to the BTS through optical fibers.
Whether to configure the optical transmission mode for E1 port 2 of the
BTS3006C/BTS3002E . If the optical transmission mode is configured, the
BSC6900 can connect to the BTS through optical fibers.

Whether to configure the optical transmission mode for E1 port 3 of the


BTS3006C/BTS3002E. If the optical transmission mode is configured, the
BSC6900 can connect to the BTS through optical fibers.
Whether to enable the limit of the tracing range

Forbidden time of cell reselection


The load handover is triggered when the traffic load in a cell is greater than the
value of this parameter.
Port number of the aggregation member
Slot number of the aggregation member

aggregation group number

Specified TRMMAP index of the user panel


TRM load threshold index
TRM load threshold index

TRM load threshold index. The TRM load threshold must be configured.
TRM load threshold index
TRM load threshold index

TRM load threshold index. It is the unique ID of the load threshold.

TRM load threshold index

Transmission resources mapping switch


TRUNK group number
TRUNK group number
Trunk group number of the logical port

Whether to enable the TRX aiding function. Four aiding modes are available.
BCCH aiding: The main BCCH is aided to another normal TRX in this cell. BCCH
aiding switchback: BCCH aiding switchback functions after the originally
configured BCCH TRX is recovered. Baseband FH aiding: When the TRX involved
in baseband FH in the cell is faulty or BCCH aiding is performed in the cell,
baseband FH aiding occurs and the cell is initialized as a non-hopping cell.
Baseband FH aiding switchback: When all the TRXs involved in baseband
hopping in the cell are recovered and the originally configured BCCH TRX is
normal, baseband FH aiding switchback can be performed and the cell is
restored to the baseband FH mode.

Duration

Frequency hopping index of the channel in the TRX

Index of a TRX, uniquely identifying a TRX in a BSC6900.

The ID of TRX added in the main location group, the TRX ID must be globally
unique. The same TRX cannot be bound by the TRX boards in a same location
group for multiple times.
Index of TRX 1

Index of TRX 10

Index of TRX 11

Index of TRX 12

Index of TRX 13

Index of TRX 14

Index of TRX 15

Index of TRX 16

Index of TRX 17

Index of TRX 18

Index of TRX 19

Index of TRX 2

Index of TRX 20

Index of TRX 21

Index of TRX 22

Index of TRX 23

Index of TRX 24

Index of TRX 3

Index of TRX 4

Index of TRX 5

Index of TRX 6

Index of TRX 7

Index of TRX 8

Index of TRX 9
List of TRX indexes. You can specify one TRX index or more TRX indexes, for
example, 1 or 0&1&2&&5 in the same BTS.

List of IDs of carriers for frequency hopping.

Mobile allocation index offset (MAIO) of the channel in the TRX

Number of a TRX in a BTS. The number of a TRX is unique in a BTS.

Allowed number of carriers bound to a board.

TRX board pass number in the sub-location group to which the TRX of the main
location group is bound
Number of the channel bound to the TRX on the TRX board. TRX Pass No. of the
DTRU/DRRU/BTS3900B of the BTS in separate mode must be 0 or 1; TRX Pass
No. of the QTRU/MRFU/GRFU/BTS3900E of the BTS in separate mode must be 0
to 5; TRX Pass No. of the GRRU/MRRU of the BTS in separate mode should in 0
to 7.
This parameter specifies whether the TRX priority is considered during channel
assignment. When the parameter is set to YES, the smaller the parameter
"TRX Priority" in the command "SET GTRXDEV" is, the higher priority the TRX is.
Under other conditions, channels are preferentially allocated from high-priority
TRXs.

Type of the TRX board bound to the TRX

It indicates the A interface timeslot number. The parameter supports multiple


values.

It indicates the Ater interface timeslot number

Timesolt of bearing channels

Timeslot number

Number of the timeslot on the port

Timeslot of the E1/T1 link carrying the PPP link. The timeslot of an E1 port
cannot be used by different PPP links.

Bearer E1/T1 port timeslot of PPP link.

Bearer E1/T1 port timeslot of MP link.

The TSC is short for the Training Sequence Code.


The TSC must be the same as the BCC. The delay equalization is performed by
using the specified TSC when the MS or BTS receives the signal. The
demodulation cannot be received because the delay equalization cannot be
performed for the signals with same frequency using different TSCs. This can
effectively prevent incorrectly invalid reception, and prevent the co-channel
interference.
Number of idle timeslots. You can configure up to 128 idle timeslots for the BTS
at a time. A BTS can be configured with up to 512 idle timeslots.
Whether to allow TSC planning. If this parameter is set to No, the TSC values in
all MA groups of the cell cannot be modified. In this case, the TSC values are
automatically refreshed to the BCC values of the cell.
Timeslot cross index

Duration in timeslot mode

Index of the monitoring timeslot. The index is unique in a BTS.

Name of the scheduled task.

Time slots for Ater operation and maintenance. These time slots are provided
by the ports connected to the Ater connection path.

The 64 kbit/s timeslots on the port are numbered from 1 to 31.

Number of the slot where the main board of the RXU ring is located. The slot
No. is unique in the same BTS.

Timeslot number of Pb signaling link

Assignment priority level of the channel. If this parameter is less, the


assignment priority level of the channel is higher.

Maximum degree by which the output power of the multi-density TRX board
can exceed the maximum output power within a short time

Fast flux measurement duration. Normal flux measurement is performed after


the fast flux measurement lasts over the period specified by this parameter.

Whether to enable fast flux detection. When this parameter is set to Open, fast
timeslot adjustment is possible after the TBF is set up.

Rate of the monitoring timeslot

Number of the subrack where the main board of the RXU ring is located. The
subrack No. is unique in the same BTS.

Test mode

Test timeslot

Type of battery test

Test Type. PIM:passive intermodulation test.

This parameter specifies whether to allow the BTS to enable the TRX Intelligent
Shutdown on Timeslot Level feature. When this parameter is set to YES and the
BTS supports this feature, the BTS will periodically report the number of times
that the TRX is shut down on the timeslot level.
RXU topology type, that is, RXU ring topology or RXU chain topology. In the
case of the ring topology, the optical ports of the head and tail boards must be
specified. In the case of the chain topology, only the optical port of the head
board must be specified.
TTL(Time to Live) of the PING packet
Indicates the live time of the packet for CFM link tracing detection

If the number of channels (including PDCH and TCH) occupied on a cell that can
be disabled is lower than this threshold, the procedure for disabling the cell can
be triggered.

This parameter specifies the end time of a period during which the cell is
disabled.

This parameter specifies the start time of a period during which the cell is
disabled.

This parameter specifies whether to enable the Dynamic Cell Power Off feature.
When this parameter is set to ENABLE, the BSC can disable the cell within the
period of time specified by "TURNOFFCELLSTRTIME" and
"TURNOFFCELLSTPTIME";
When this parameter is set to DISABLE, the BSC will never disable the cell;
When this parameter is set to SLEEP, the BSC will disable the cell
unconditionally within "TURNOFFCELLSTRTIME" and
"TURNOFFCELLSTPTIME",and enable the cell unconditionally within the other
time.Currently, this parameter can be set to SLEEPING only for the BTS3900E.
For other base stations, this parameter cannot be set to SLEEPING.

When the load of the same coverage cell is higher than this threshold for a
period, the disabled cell is enabled.
Temperature alarm upper threshold. If the temperature of the battery is higher
than the value of this parameter, an alarm indicating the abnormal temperature
is reported.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Temperature upper threshold of the cabinet. When the cabinet temperature is
higher than this parameter, an alarm indicating the abnormal cabinet
temperature is reported.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Value of the timer for reserving the channels in the observed cell

Value of the timer for reserving the TRXs in the observed cell

Value of the timer for reserving the TCHFs in the serving cell

Value of the timer for waiting for the response to information collection

Value of the timer for searching for the MS

Value of the timer for activating the reserved resources of the BTS

Value of the timer for waiting for the synchronization report from the BTS
(RET), and S related to channel combination.
This parameter works with the configuration of the CCCH to determine the
parameter S. The relations between this parameter and the configuration of the
CCCH are as follows:
When this parameter is set to 3, 8, 14, or 50, S is 55 if the CCCH and SDCCH do
not share a physical channel.
When this parameter is set to 3, 8, 14, or 50, S is 41 if the CCCH and SDCCH
share a physical channel.
When this parameter is set to 4, 9, or 6, S is 76 if the CCCH and SDCCH do not
share a physical channel.
When this parameter is set to 4, 9, or 6, S is 52 if the CCCH and SDCCH share a
physical channel.
When this parameter is set to 5, 10, or 20, S is 109 if the CCCH and SDCCH do
not share a physical channel.
When this parameter is set to 5, 10, or 20, S is 58 if the CCCH and SDCCH share
a physical channel.
When this parameter is set to 6, 11, or 25, S is 163 if the CCCH and SDCCH do
not share a physical channel.
When this parameter is set to 6, 11, or 25, S is 86 if the CCCH and SDCCH share
a physical channel.
When this parameter is set to 7, 12, or 32, S is 217 if the CCCH and SDCCH do
not share a physical channel.
When this parameter is set to 7, 12, or 32, S is 115 if the CCCH and SDCCH
share a physical channel.
The timeslot for sending messages is a random value from the collection of {0,
1..., MAX(T, 8)-1}.
The number of timeslots (excluding the timeslot used to send messages)
between two adjacent channel request messages is a random value from the
collection of {S, S+1, ..., S+T-1}.
When T increases, the interval between two adjacent channel requests
increases, and RACH conflicts decrease.
When S increases, the interval between two adjacent channel request

The maximum power that operators 1 can use on pass A of MRRU board.

The maximum power that operators 2 can use on pass A of MRRU board.

The maximum power that operators 3 can use on pass A of MRRU board.

The maximum power that operators 4 can use on pass A of MRRU board.

The maximum power that operators 1 can use on pass B of MRRU board.

The maximum power that operators 2 can use on pass B of MRRU board.

The maximum power that operators 3 can use on pass B of MRRU board.

The maximum power that operators 4 can use on pass B of MRRU board.

Transmit bandwidth of IP path

Transmit bandwidth

Extension transmission timeslots of random access. This parameter determines


the interval of sending another channel request after the MS fails to request a
channel.
Indicates the interval between the two sent PING packets
Frequency band to which the newly added cell belongs. Only one frequency
band can be selected as the frequency band of each new cell and it cannot be
changed after the selection. To modify the frequency band of the new cell, you
must delete the cell and then add it again.

Type of the subrack

This parameter specifies the frequency band of new cells. Each new cell can be
allocated frequencies of only one frequency band. Once the frequency band is
selected, it cannot be changed.
GSM900: The cell supports GSM900 frequency band.
DCS1800: The cell supports DCS1800 frequency band.
GSM900_DCS1800: The cell supports GSM900 and DCS1800 frequency bands.
GSM850: The cell supports GSM850 frequency band.
GSM850_DCS1800: The cell supports GSM850 and DCS1800 frequency bands.
PCS1900: The cell supports PCS1900 frequency band.
GSM850_PCS1900: The cell supports GSM850 and PCS1900 frequency bands.

Type of the PCU

Explanation of the finish type of the batch commands


1. ANY_ERR_RETURN: If there is a command whose execution fails, the
execution of the batch commands is stopped and the execution of the file fails.
2. ALL_END_RETURN: If all commands in the batch file are executed in one
operation, the execution of the file is successful no matter whether there is
execution failure in the process.

Type of a cabinet

Cell type. Currently, the fast BTS construction is available for only GSM900 and
DCS1800 cells.
Power attenuation factor of uplink tributary 0

Whether there is a TMA on uplink tributary 0


Index of uplink tributary 0. Each uplink tributary can be configured with a
maximum of 12 TRXs. This parameter indicates the serial number of a TRX on
the uplink tributary.
TRX board pass number connected to uplink tributary 0
Number of the slot where the TRX board that connects to uplink tributary 0 is
located
Number of the subrack where the TRX board that connects to uplink tributary 0
is located
Power attenuation factor of uplink tributary 1

Whether there is a TMA on uplink tributary 1


Index of uplink tributary 1. Each uplink tributary can connect to a maximum of
12 TRXs. This parameter indicates the serial number of a TRX on the uplink
tributary.
TRX board pass number connected to uplink tributary 1
Number of the slot where the TRX board that connects to uplink tributary 1 is
located
Number of the subrack where the TRX board that connects to uplink tributary 1
is located
Service priority of call reestablishment when CS services are preferred. This
parameter is used for the flow control in the case of Abis over IP/HDLC.
Service priority of the CS emergency call when CS services are preferred. This
parameter is used for the flow control in the case of Abis over IP/HDLC.
Service priority of the CS MS-originated call when CS services are preferred.
This parameter is used for the flow control in the case of Abis over IP/HDLC.
Service priority of the CS MS-terminated call when CS services are preferred.
This parameter is used for the flow control in the case of Abis over IP/HDLC.
Service priority of the incoming BSC handover when CS services are preferred.
This parameter is used for the flow control in the case of Abis over IP/HDLC.
Service priority of the intra-BSC handover when CS services are preferred. This
parameter is used for the flow control in the case of Abis over IP/HDLC.
Priority of other services when CS services are preferred. This parameter is
used for the flow control in the case of Abis over IP/HDLC.
PS service priority when CS services are preferred. This parameter is used for
the flow control in the case of Abis over IP/HDLC.
Priority of supplementary services when CS services are preferred. This
parameter is used for the flow control in the case of Abis over IP/HDLC.
VBS service priority when CS services are preferred. This parameter is used for
the flow control in the case of Abis over IP/HDLC.

VGCS service priority when CS services are preferred. This parameter is used
for the flow control in the case of Abis over IP/HDLC.
In A over IP, if the parameter is set to ON, the circuit IE in the A interface
extended signaling must be processed in the same way as that in A over non-IP.
Otherwise, the A interface extended signaling cannot carry circuit-type IE.
Whether the BSC selects the TCHs on the link that reports an RAI alarm.

Reestablish service priority of a PS preferred call

CS emergency call service priority of a PS preferred call

CS original call service priority of a PS preferred call

CS terminated call service priority of a PS preferred call

BSC handover service priority of a PS preferred call

BSC intra handover service priority of a PS preferred call

Other service priority of a PS preferred call

PS service priority of a PS preferred call

Supplement service priority of a PS preferred call

VBS service priority of a PS preferred call

VGCS service priority of a PS preferred call

In case of intra-BSC, if this parameter is set to ON, the same channel type and
voice version as those of the original channel are selected.
UDP multiplexing mode of the receiving party. The mode that does not support
the function of compressing the RTP header indicates that the receiving party
supports the UDP MUX RTP header but not the function of compressing the RTP
header. The mode that supports the function of compressing the RTP header
indicates that the receiving party supports both the UDP MUX RTP header and
the function of compressing the RTP header.

UDP multiplexing mode of the sending party. If the mode that does not support
the function of compressing the RTP header indicates that the sending party
supports the UDP MUX RTP header but not the function of compressing the RTP
header. The mode that supports the function of compressing the RTP header
indicates that the sending party supports both the UDP MUX RTP header and
the function of compressing the RTP header.
UDP port number of the local NSVL. The setting of this parameter must be
consistent with the setting at the SGSN side.

UDP port number of the remote NSVL. The setting of this parameter must be
consistent with the setting at the SGSN side.

Group to which the operator belongs. This parameter is used to limit the right
of the operator.

Upper humidity threshold for the environment alarm box to report an alarm
indicating that the ambient humidity is too high. If the ambient humidity of the
BTS is higher than this threshold, the environment alarm box reports the alarm.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.

Used to identify the uplink access message from the MS. The value 64 is
invalid.
Unit time for the error code ratio test
Upper limit for triggering an alarm

Upper limit of the alarm. This parameter is valid for the analog port.

Minimum interval between two consecutive uplink power control commands

Current call is an AMR full-rate call, and when the uplink receive quality is
greater than the threshold, Huawei III power control is performed.

Current call is an AMR full-rate call, and when the uplink receive quality is lower
than the threshold, Huawei III power control is performed.

Current call is an AMR half-rate call, and when the uplink receive quality is
greater than the threshold, Huawei III power control is performed.

Current call is an AMR half-rate call, and when the uplink receive quality is
lower than the threshold, Huawei III power control is performed.

The P/N criterion must be met for triggering a UL BQ handover. That is, the UL
BQ handover can be triggered only if P measurement reports among N
measurement reports meet the triggering conditions. This parameter
corresponds to P in the P/N criterion.

The P/N criterion must be met for triggering a UL BQ handover. That is, the UL
BQ handover can be triggered only if P measurement reports among N
measurement reports meet the triggering conditions. This parameter
corresponds to N in the P/N criterion.

If the ratio of uplink flux to downlink flux is greater than or equal to the
threshold during the fast flux measurement, the uplink services takes priority.
Duration for uplink data transmission on the original channel if the TC resources
are changed before and after the handover

Number of downlink GRPS TBF RLC blocks sent before RRBP field is sent

If the UL receive level remains lower than the "Edge HO UL RX_LEV Threshold"
for a period, the edge handover is triggered.

Number of downlink GRPS TBF RLC blocks sent before RRBP field is sent

Period of acknowledging the EGPRS TBF RLC uplink data block

Filter adjustment factor for uplink power control. If this parameter is set to a
large value, the filtered values become smooth, thus reducing the impact of
poor measurement reports on the filtered values. If this parameter is set to a
small value, the filter values are close to the actual ones and thus the power
control speed is increased.

Current call is a full-rate call, and when the uplink receive quality is greater
than the threshold, Huawei III power control is performed.

Current call is a full-rate call, and when the uplink receive quality is lower than
the threshold, Huawei III power control is performed.

Current call is a half-rate call, and when the uplink receive quality is greater
than the threshold, Huawei III power control is performed.

Current call is a half-rate call, and when the uplink receive quality is lower than
the threshold, Huawei III power control is performed.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.
When the uplink load of a cell is larger than the value of this parameter and is
smaller than "2G Cell UL Overload Congest Thred", the uplink of the cell is in
the basic congestion status.
When the network receives measurement reports, in consideration of the
accuracy of a single measurement report, the measurement values in certain
measurement reports are filtered to represent the radio operating environment.
This parameter specifies the number of measurement reports sampled for
filtering the uplink signal strength.

Maximum permissible adjustment step when the BSC decreases the uplink
transmit power

Maximum permissible adjustment step when the BSC increases the uplink
transmit power

When the uplink load of a cell is greater than the value, the uplink of the cell is
in the overload congestion status.

After the BSC delivers the power control command, it should wait for a certain
period before affirming the effect of the power control. Therefore, the MR that
power control decision is based on cannot accurately reflect the radio
environment during the power adjustment, but misses the latest changes of the
receive level and receive quality of the MS. Thus, the power adjustment is
delayed.
To compensate the delay of power adjustment, the power control algorithm
implements the prediction and filtering function. In other words, the BSC
samples several uplink measurement reports, performs weighted filtering, and
predicts N measurement reports from the current time onwards in a short
period.
This parameter determines the number of uplink measurement reports
predicted by the BSC. In other words, the value of this parameter equals to the
previous number N.

The MS transmit power is decreased only when the quality level of the MS
transmit signal is smaller than the value of the parameter. If (the uplink receive
level - MAX Up Adj. PC Value by Qual) is smaller than "UL RX_LEV Lower
Threshold", the MS transmit power is not adjusted.

The MS transmit power is increased only when the quality level of the MS
transmit signal is greater than the value of the parameter. If (the uplink receive
level + MAX Up Adj. PC Value by Qual) is greater than "UL RX_LEV Upper
Threshold", the MS transmit power is not adjusted.

When the network receives measurement reports, the measurement values in


several straight measurement reports are filtered to reflect the radio operating
environment for the sake of accuracy. This parameter specifies the number of
measurement reports sampled for filtering the uplink signal quality.
In the case of power control, when the uplink receive quality is not smaller than
"UL Qual. Bad Trig Threshold", the actual "UL RX_LEV Upper Threshold" is
increased by "UL Qual. Bad UpLEVDiff".
In the case of power control, when the uplink receive quality is not smaller than
"UL Qual. Bad Trig Threshold", the actual "UL RX_LEV Upper Threshold" is
increased by "UL Qual. Bad UpLEVDiff".

An emergency handover due to bad quality is triggered when the uplink receive
quality is not smaller than "UL Qual. Threshold".

The value of this parameter corresponds to multiplying quality level 0 to 7 by


10. An emergency handover can be triggered only when the uplink receive
quality of the MS is greater than the value of this parameter.

The value of this parameter corresponds to multiplying quality level 0 to 7 by


10. An emergency handover can be triggered only when the uplink receive
quality of the MS is greater than the value of this parameter.

This parameter specifies the uplink signal strength factor multiplied by 10


during the calculation of the uplink power control step. The uplink signal
strength factor is a coefficient indicating how much the signal strength is
considered during the calculation of the uplink power control step.
When the network receives measurement reports, the measurement values in
several straight measurement reports are filtered to reflect the radio operating
environment for the sake of accuracy. This parameter specifies the number of
measurement reports sampled for exponent filtering of the uplink signal
strength.

When the uplink receive level reaches the threshold, Huawei III power control is
performed.

When the uplink receive level is lower than the threshold, Huawei III power
control is performed.

When the network receives measurement reports, the measurement values in


several straight measurement reports are filtered to reflect the radio operating
environment for the sake of accuracy. This parameter specifies the number of
measurement reports sampled for slide-window filtering of the uplink signal
strength.
This parameter specifies the uplink quality level factor multiplied by 10 during
the calculation of the uplink power control step. The uplink quality level factor
is a coefficient indicating how much the quality level is considered during the
calculation of the uplink power control step.
When the network receives measurement reports, the measurement values in
several straight measurement reports are filtered to reflect the radio operating
environment for the sake of accuracy. This parameter specifies the number of
measurement reports sampled for exponent filtering of the uplink signal quality.
When the network receives measurement reports, the measurement values in
several straight measurement reports are filtered to reflect the radio operating
environment for the sake of accuracy. This parameter specifies the number of
measurement reports sampled for slide-window filtering of the uplink signal
quality.
Signal strength factor for the protective limitation on calculating the uplink
power control adjustment step. The calculated step value cannot exceed the
step value that is obtained on the basis of the signal strength protection factor
and the signal quality protection factor.
Signal strength factor for the protective limitation on calculating the uplink
power control adjustment step. The calculated step value cannot exceed the
step value that is obtained on the basis of the signal strength protection factor
and the signal quality protection factor.

When the uplink receive level reaches the threshold, Huawei II power control is
performed.

When the uplink receive level is below the threshold, Huawei II power control is
performed.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Based on the RQI in the call measurement report, the BTS and MS automatically
adjust the current speech coding rate according to the related algorithm. The
coding rate adjustment threshold is the threshold of RQI. The RQI indicates the
carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if
RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates
in the ACS, there is an adjustment threshold and an adjustment hysteresis
between the neighboring coding rates.

Whether a UL subcell to OL subcell handover is allowed

Number of uplink GRPS TBF RLC blocks sent before an acknowledgement is


required
Whether the crosstalk optimization function over the Um interface is allowed. If
this parameter is set to YES when call drops occur on the Um interface, this
function can avoid crosstalk due to very early assignment of the channel that is
not released.
If this parameter is set to YES and the ongoing service is speech service, the
BSC also sends the Channel Release message to the MS and starts the timer
T3109 when a call drop occurs upon the reception of the Conn Fail or Err Ind
message reported by the MS.

Timer of penalty on a neighboring cell when a handover fails due to faults of air
interface connection.

Phase tag for GSM protocols that the Um interface supports

Whether to support the balanced mode or the unbalanced mode. When this
parameter is set to YES, you can set the DIP switches on the interface boards.
You do not need to set the DIP switches by turning them inwards or outwards. In
this case, an interface board can be made to work in E1_UNBA, E1_BA, or T1
mode. When this parameter is set to NO, you cannot set the DIP switches on
the interface boards. You must set the DIP switches by turning them inwards or
outwards. In this case, an interface board can be made to work in E1 or T1
mode.

Retry times after the peer response timer expires during NSVC unblocking
Abnormally alarm triggering threshold when the ANT_A tributary antenna
current is too light. When the actual current is lower than the configured value,
the ALD Current Abnormally Alarm is triggered with the corresponding alarm
tributary No. of 1.
Abnormally alarm triggering threshold when the ANT_B tributary antenna
current is too light. When the actual current is lower than the configured value,
the ALD Current Abnormally Alarm is triggered with the corresponding alarm
tributary No. of 1.
Abnormally alarm triggering threshold when the RET tributary antenna current
is too light. When the actual current is lower than the configured value, the ALD
Current Abnormally Alarm is triggered with the corresponding alarm tributary
No. of 1.

Abnormally alarm clearance triggering threshold when the ANT_A tributary


antenna current is too light. When the actual current is higher than the
configured value, the ALD Current Abnormally Alarm disappears with the
corresponding alarm tributary No. of 1.
Abnormally alarm clearance triggering threshold when the ANT_B tributary
antenna current is too light. When the actual current is higher than the
configured value, the ALD Current Abnormally Alarm disappears with the
corresponding alarm tributary No. of 1.
Abnormally alarm clearance triggering threshold when the RET tributary
antenna current is too light. When the actual current is higher than the
configured value, the ALD Current Abnormally Alarm disappears with the
corresponding alarm tributary No. of 1.
Index of upper-level BTS connected to the BTS

Number of the upper-level BTS. The number is unique in a BSC6900.

Index type of upper-level BTS connected to the BTS

Index type of the upper-level BTS


Name of the upper-level BTS connected to the BTS. The BTS name is unique
within a same BSC6900. This parameter cannot contain , ; = " ' more than two
(include two) %, more than two (include two) space, more than three (include
three) +.
Name of the upper-level BTS. The name is unique in a BSC6900. The invalid
characters (\, /, :, *, ?, ", <, >, |, and #) cannot appear in the name.
Update code for a simple cell broadcast message.
This parameter together with "Code" uniquely identifies a cell broadcast
message.
Default coding scheme of the uplink GPRS link. If the uplink adopts the dynamic
adjustment coding scheme, this parameter can be used to set the coding
scheme for transmission during initial access. If the uplink uses the fixed coding
scheme, the TBF uses the fixed coding scheme.
Default coding scheme of the uplink EDGE link. If the uplink adopts the
dynamic adjustment coding scheme, this parameter can be used to set the
coding scheme for transmission during initial access. If the uplink uses the fixed
coding scheme, the TBF uses the fixed coding scheme.

Uplink multiplex threshold of dynamic channel conversion. When the subscriber


number on the channel reaches the value (threshold/10), the dynamic channel
conversion application is triggered. We recommand that the value of "Uplink
Multiplex Threshold of Dynamic Channel Conversion" should be less than
"PDCH Uplink Multiplex Threshold" for triggering converting dynamic channel in
time and reducing PDCH multiplex.

Default coding scheme used on the uplink EGPRS2-A link. If the uplink uses the
dynamic coding scheme, this parameter specifies the coding scheme that is
used for the transmission in initial access. If the uplink uses the fixed coding
scheme, the TBF uses the fixed coding scheme.
Fixed coding scheme that is used on the uplink EGPRS2-A link. If the uplink uses
the fixed coding scheme, this parameter can be set to any one in MCS1-6 and
UAS7-11. If the uplink uses the dynamic coding scheme, this parameter can be
set to UNFIXED.

Inactive period of extended uplink TBF. After the network side receives the last
uplink RLC data block (CountValue=0) of the MS supporting the extended
uplink TBF, the uplink TBF is not released immediately. Instead, the uplink TBF
is set to the inactive state. In the inactive period, if the MS needs to transmit
the uplink RLC data block, the MS can use the inactive uplink TBF without
rebuilding a new uplink TBF. This inactive uplink TBF is switched to the active
state automatically. At the end of the inactive period, if the MS does not
transmit the uplink RLC data block, the network side sends the message Packet
Uplink Ack/Nack to notify the MS of releasing the uplink TBF. When the uplink
TBF is inactive, the downlink TBF can be established according to this uplink
TBF. 0: disable the function of the extended uplink TBF (this function can be
disabled on the BSC side).

Adjustment mode of the uplink GPRS link coding scheme. If the fixed coding
scheme is used, this parameter is a value ranging from CS1 to CS4. If the
dynamic coding scheme is used, this parameter is set to UNFIXED.
Coding scheme of the uplink EDGE link. If the uplink uses the fixed coding
scheme, this parameter is set to a value ranging from MCS1 to MCS9. If the
uplink uses the dynamic adjustment coding scheme, this parameter is set to
UNFIXED.
One of the thresholds to determine whether the uplink interference exists. If
the uplink level is not smaller than "Interf.of UL Level Threshold" and the uplink
quality of the channel is not less than "Interf.of UL Qual. Threshold", the uplink
interference exists.

One of the thresholds to determine whether the uplink interference exists. If


the uplink level is not smaller than "Interf.of UL Level Threshold" and the uplink
quality of the channel is not less than "Interf.of UL Qual. Threshold", the uplink
interference exists.
Maximum time in which a user uses the uplink of its VGCS call continuously
when the BTS works in fallback mode
Size of the OML/ESL/EML Uplink LAPD Window

Whether to allow MS power control

Upper class transport resource group No. It is valid only when " Is First Class
Transport Resource Group " is set to NO.
Upper number of the logical port
If the difference between uplink receive levels of calls within the same timeslot
is greater than "Offset of the difference between uplink received levels" for P
seconds among N seconds, the call with weak uplink receive level within the
timeslot will be handed over to another timeslot. This parameter corresponds to
P in the P/N criterion.
After the existing uplink receive level, uplink receive level after the previous
optimization, and the value of this parameter are weight-averaged, the uplink
receive level after the optimization at this time is obtained and used for
determing the difference between the uplink receive levels.
If the difference between uplink receive levels of calls within the same timeslot
is greater than "Offset of the difference between uplink received levels" for P
seconds among N seconds, the call with weak uplink receive level within the
timeslot will be handed over to another timeslot. This parameter corresponds to
N in the P/N criterion.

This parameter specifies whether the transmission of point-to-point short


messages is disabled. If necessary, the transmission of the uplink short
messages in a specific cell can be disabled so that sufficient radio channels can
be seized by normal calls.
Delay of releasing the non-extended uplink TBF. After receiving the last uplink
RLC data block (CountValue=0), the network side sends the message Packet
Uplink Ack/Nack with FAI=1 to notify the MS of releasing the uplink TBF. After
this parameter is set, the network side notifies the MS of releasing this TBF
after specified delay. In this way, the downlink TBF can be established on the
unreleased uplink TBF. This uplink TBF is automatically released when the
downlink TBF is established or when the delay duration exceeds the time set by
the uplink non-extended TBF. If this parameter is set to 0, the release delay of
non-extended TBF is disabled.
Retransmission threshold when the coding mode of the uplink TBF is changed
from CS2 to CS1. When the retransmission rate of the uplink TBF is greater than
or equal to this threshold, the coding mode of the uplink TBF is changed from
CS2 to CS1.
Retransmission threshold when the coding mode of the uplink TBF is changed
from CS3 to CS2. When the retransmission rate of the uplink TBF is greater than
or equal to this threshold, the coding mode of the uplink TBF is changed from
CS3 to CS2.
Retransmission threshold when the coding mode of the uplink TBF is changed
from CS4 to CS3. When the retransmission rate of the uplink TBF is greater than
or equal to this threshold, the coding mode of the uplink TBF is changed from
CS4 to CS3.
Retransmission threshold when the coding mode of the uplink TBF is changed
from CS1 to CS2. When the retransmission rate of the uplink TBF is less than or
equal to this threshold, the coding mode of the uplink TBF is changed from CS1
to CS2.
Retransmission threshold when the coding mode of the uplink TBF is changed
from CS2 to CS3. When the retransmission rate of the uplink TBF is less than or
equal to this threshold, the coding mode of the uplink TBF is changed from CS2
to CS3.
Retransmission threshold when the coding mode of the uplink TBF is changed
from CS3 to CS4. When the retransmission rate of the uplink TBF is less than or
equal to this threshold, the coding mode of the uplink TBF is changed from CS3
to CS4.
Whether to allow cell urgent reselection. If this parameter is set to PERMIT and
[NC2 Load Reselection Switch is set to Support, the load of the target cell is
involved in the algorithm for NC2 cell reselection.

Mode of querying the information on an MS

Whether to support USF granularity 4

User name of the FTP server

User name for the FTP server. When the FTPServer.exe file downloaded through
the LMT is installed, the user name is admin.

Start time when the TRX energy saving function is enabled for the BTS3002E.

End time when the TRX energy saving function is enabled for the BTS3002E.

Upper temperature threshold for the environment alarm box to report an alarm
indicating that the ambient temperature is too high. If the ambient temperature
of the BTS is higher than this threshold, the environment alarm box reports the
alarm.
In multi-mode scenario, the value of this parameter in this mode must be the
same as the value of the corresponding parameter in another mode.
When a UL subcell-OL subcel handover decision is performed to a call, the BSC
determines whether the number of handover failures reaches the "MaxRetry
Time after UtoO Fail". If the number reaches the threshold, the UL subcell to OL
subcell handover is prohibited. Otherwise, the UL subcell to OL subcell
handover is allowed.
After an MS performs a OL subcell to UL subcell handover successfully, the MS
cannot be handed over to the OL subcell again within the value of the
parameter.

One of the parameters that determine the coverage of the OL subcell and of
the UL subcell. "UtoO HO Received Level Threshold", "OtoU HO Received Level
Threshold", "ReceiveQualThrshAMRFR", "TA Threshold", and "TA Hysteresis"
determine the coverage of the OL subcell and UL subcell.

When this parameter is set to YES, the existing call is performed in the OL
subcell, and "OL to UL HO Allowed" is set to YES, an OL subcell to UL subcell
handover is triggered if the traffic volume in the UL subcell is smaller than "En
Iuo Out Cell Low Load Thred".
If the existing call is performed in the UL subcell, a UL subcell to OL subcell
handover is triggered, and "UL to OL HO Allowed" is set to YES, the timer is
started and the calls in the UL subcell are hierarchically handed over to the OL
subcell if the traffic volume in the UL subcell reaches "En Iuo Out Cell General
OverLoad Thred". Otherwise, if the traffic volume in the UL subcell is smaller
than "En Iuo Out Cell General OverLoad Thred", the timer stops, and
hierarchical handovers are not performed.
If this parameter is set to NO, the traffic volume in the UL subcell is not taken
into account for triggering the UL subcell to OL subcell handover or the OL
subcell to UL subcell handover in an enhanced concentric cell.

Hierarchical handover period of the load handover from the UL subcell to the
OL subcell. If the channel seizure ratio of the UL subcell is greater than the UL
subcell general overload threshold, all the calls in the cell send handover
requests at the same time and the load on the BSC increases in a short time.
Thus, congestion may occur in the target cell and call drops may be caused.
Through the hierarchical load handover algorithm, the calls in the cell are
handed over to the OL subcell by level. This parameter indicates the duration
for which each each level of handover lasts.

Hierarchical level step of the load handover from the UL subcell to the OL
subcell

This parameter specifies the type of a 3G cell. A cell type can be Frequency
Division Duplex (FDD) or Time Division Duplex (TDD).
Vendor code of the RET antenna

This parameter is used to limit the maximum number of channels that can be
used by the VGCS in a cell. This prevents too many channels in the cell from
being occupied by the VGCS and thus prevents public network services from
being affected. When this parameter is set to 255, the maximum number is not
limited.

This parameter specifies whether the preemption of channels between public


network services and the VGCS is allowed when preemption conditions are met.

This parameter is used to reserve a certain number of channels in a cell for the
Voice Group Call Service (VGCS) to use directly. The specified channels are
unavailable to public network services.

This parameter specifies the usage threshold of the CPU for VIP user calls that
can be admitted. When the usage of a CPU is greater than this threshold, the
new service requests from VIP users are transferred to another CPU for
processing. When the usage of all CPUs is greater than this threshold, all new
service requests are rejected.

Is VIP Cell.The parameter is used for BSC6900 flow control.


This parameter specifies the eMLPP priority value corresponding to the VIP call.
When the eMLPP(Enhanced Multi-Level Precedence and Pre-emption service)
priority value of a user is greater than or equal to the value of this parameter,
the user is a VIP user.
This parameter specifies the usage threshold of the CPU for VIP user calls that
are transferred from other CPUs. When the usage of a CPU is greater than this
threshold, the VIP service requests transferred from other CPUs are directly
discarded.
If the parameter is set to Disable, the added IP path is not configured with the
VLAN ID. If the parameter is set to Enable, the added IP path is configured with
the VLAN ID.
Specified Vlan enabling flag

VLANID flag of first local IP address

VLANID Flag of second Local IP address

VLANID of the IP address of the specified next hop

VLAN ID of the service type


VLAN of the MA in the MD
VLAN to which the maintenance association belongs in the maintenance
domain.
VLAN ID of first Local IP address

VLAN ID of second Local IP address

VLAN priority level of the service type. This parameter helps to determine the
packet service priority level at the data link layer on the Ethernet. If this
parameter is set to 0, the service type has the highest VLAN priority level. If
this parameter is set to 7, the service type has the lowest VLAN priority level.

VLAN priority

VLAN switch for the service type

Speech version supported by a cell

24V voltage alarm switch

Upper limit for triggering a 24 V voltage sensor alarm

Lower limit for triggering a 24 V voltage sensor alarm

48V voltage alarm switch

Upper limit for triggering a 48V voltage sensor alarm

Lower limit for triggering a 48V voltage sensor alarm

Whether to enable the standing wave alarm parameters to be configured


This parameter specifies a condition for generating a BTS alarm. This
parameter together with "VSWR TRX error threshold" is used to detect whether
the antenna system connected to the TRX is faulty.
Filtering times of serious standing wave alarms

Standing wave alarm threshold. When the VSWR is greater than the value of
this parameter, the TRX reports a standing wave alarm.

Serious standing wave alarm threshold. When the VSWR is greater than the
value of this parameter, the TRX reports a serious standing wave alarm.

This parameter specifies a condition for generating a BTS alarm. This


parameter together with "VSWR TRX unadjusted threshold" are used to check
whether the antenna system connecting to the TRX is faulty. If the value of this
parameter is smaller, the error is smaller.
V-version number of the BTS software
This timer is used to set the time of waiting for a ReleaseIndication message
after a ChannelRelease message is sent. If the timer expires, the channel is
deactivated.
When the BSC6900 sends a ChannelRelease message and the current call uses
the AMRFR encoding mode, the timer T3109 (AMRFR) is started. If the BSC6900
receives the ReleaseIndication message before the T3109 (AMRFR) timer
expires, the timer T3109 (AMRFR) is stopped. If the timer T3109 (AMRFR)
expires, the BSC6900 deactivates the channel.
When the BSC sends a ChannelRelease message and the current call uses the
AMRHR encoding mode, the timer T3109 (AMRHR) is started. If the BSC
receives the ReleaseIndication message before the T3109 (AMRHR) timer
expires, the timer T3109 (AMRHR) is stopped. If the timer T3109 (AMRHR)
expires, the BSC deactivates the channel.
Timer of waiting for the MS's response to the location measurement request
sent from the BSC. If the BSC does not receive the measurement information
reported by the MS before the timer expires, then the MS location fails.

The TCHs reserved for the emergency call are assigned to the user during the
service assignment. If the TCHs are not assigned to the emergency call within a
period, the TCHs are released from the reservation queue.

When the dynamic PDCH needs to use MAIO of the SDCCH, the SDCCH is not
allowed to be assigned to new calls within the value of the parameter. After the
timer expires, check whether the SDCCH is idle. If the SDCCH is idle, MAIO of
the SDCCH is allowed to be preempted. If the channel is not idle, the MAIO is
not allowed to be preempted.
Timer of waiting for the SMLC's response to the MS location request sent from
the MSC. If the SMLC does not send any response to the MS location request
before the timer expires, then the MS location fails. In this case, the BSC sends
a Perform Location Abort message to the SMLC for stopping the MS location and
sends an MS location failure indication to the MSC.
Whether to start the heating equipment of the BTS.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Water sensor alarm switch
Whether to limit the operation weekday of the operator. If the weekday needs
to be limited, see the description of "Week".
This parameter is used to select the location of a cell, east or west longitude.
Whether to start the humidification equipment of the BTS.
In multi-mode scenario, the value of this parameter in one mode must be the
same as the value of the corresponding parameter in another mode.
Whether to trigger an active/standby port switchover. If this parameter is set to
YES, an active/standby port switchover is triggered when a fault is detected on
the active port. If this parameter is set to NO, an active/standby port switchover
is not triggered when a fault is detected on the active port.
Whether to start the dynamic adjustment of the LAPD window. If this parameter
is set to ALLOW, the LAPD transmit and receive window is enlarged when the
delay is increased, which improves the transmission efficiency of LAPD but
consuming more buffer resources in the memory of the LAPD.

You can select multiple weekdays.


Working mode of the M3UA link set, including M3UA_ASP and M3UA_IPSP. For
details about the ASP and IPSP, see the RFC4666.

Time when the BTS stops checking for a radio link alarm. If this time is up, the
BTS stops checking for or reporting a radio link alarm until the next alarm
detection start time is up.
Whether to enable the BTS to report a major radio link alarm. If this parameter
is set to YES, the BTS reports a major radio link alarm when a radio link warning
is not cleared within "WLARP". If this parameter is set to NO, the BTS does not
report any major radio link alarm.
Period for clearing a radio link warning. If a radio link warning is cleared within
this period, the BTS reports the recovery alarm for the warning. If a radio link
warning is not cleared within this period, the BTS determines whether to report
a major radio link alarm according to "WLAFLAG".
Time when the BTS starts to check for a radio link alarm. If this time is up, the
BTS starts to check for and report a radio link alarm.
Whether to enable the BSC to deliver radio link alarm parameters to the BTS. If
this parameter is set to YES, the BSC delivers the radio link alarm parameters
to the BTS. If this parameter is set to NO, the BSC does not deliver the radio
link alarm parameters to the BTS.
Flag of the work area to be formatted

Working mode of the RXU board

Work mode of subrack

Working mode. E1: The E1 system is recommended by the IUT-T. E1 carries


signals at 2.048 Mbit/s. G.703 defines the electrical specification and G.704
defines the frame format for E1 telecommunication lines. The E1 system is
used in Europe and China.
T1: The T1 system is recommended by the ANSI and widely used in the North
America. T1 carries signals at 1.544 Mbit/s.
E1_BA: A circuit that uses two wires to transmit the same but contra-directional
signals. The 120-ohm E1 line and 100-ohm T1 line are typical balanced circuits.
The balanced circuit must use the balanced cable, that is, twisted-pair cable
consisting of two wires.
E1_UNBA: A circuit that uses one transmission signal cable and one common
grounding cable to transmit signals. The 75-ohm E1 line is a typical unbalanced
circuit. The unbalanced circuit must use the unbalanced cable, that is, coaxial
cable.

BTS port working mode. This parameter must be consistent with that of the
peer. Work mode of a BTS. A BTS can work in the following modes:
E1: The E1 system is recommended by the ITU-T. E1 carries signals at 2.048
Mbit/s. G.703 defines the electrical specification and G.704 defines the frame
format for E1 telecommunication lines. The E1 system is used in Europe and
China.
T1: The T1 system is recommended by the ANSI and widely used in the North
America. T1 carries signals at 1.544 Mbit/s.
If "DESTNODE" of the BTS is set to BSC, BTS, or DXX, the setting of
"WORKMODE" of the BTS port must be the same as that of the BSC interface
board. The operator needn't set "WORKMODE" of the BTS port, it is
automatically set to the same value as that of the BSC interface board.
If "DESTNODE" of the BTS is set to OTHER, for example, TGW(Transmission
Gateway), "WORKMODE" of the BTS port must be set to E1(E1) or T1(T1),
according to the physical connection.
The setting of the E1/T1 DIP switch of the BTS must match the setting of
"WORKMODE" of the BTS port.

Window size of the Ater signaling link


Time for which the BTS waits to swap the OML after the OML is interrupted.
With this parameter, the BTS does not swap the OML when the OML is
interrupted transiently.

Waiting time before establishing a link in the reverse direction after the
transmission of a BTS is disrupted

Wait to restore time

Time zone

Feature ID

Feature Name

Value Type

GBFD-110502

Assignment and Immediate


Assignment

Interval Type

GBFD-110502

Assignment and Immediate


Assignment

Interval Type

GBFD-110502

Assignment and Immediate


Assignment

Interval Type

GBFD-116601

Abis Bypass

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-114201

EGPRS

Enumeration Type

GBFD-114201

EGPRS

Enumeration Type

GBFD-117702

BTS Local Switch

Interval Type

GBFD-117301

Flex Abis

Enumeration Type

GBFD-113101

PDCH Dynamic Adjustment

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Interval Type

GBFD-119110

Access

Enumeration Type

GBFD-119110

Access

Interval Type

GBFD-511002

Access Control Class(ACC)

Enumeration Type

GBFD-511002

Access Control Class(ACC)

Interval Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-511002

Access Control Class(ACC)

Interval Type

GBFD-119501

Adaptive Adjustment of Uplink and


Downlink Channels

Enumeration Type

GBFD-511002

Access Control Class(ACC)

Interval Type

GBFD-511002

Access Control Class(ACC)

Interval Type

GBFD-511002

Access Control Class(ACC)

Interval Type

GBFD-118611

Abis IP over E1/T1

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-119305

BSS Paging Coordination

Enumeration Type

GBFD-110402
GBFD-111101

Basic Cell Re-selection


System Information Sending

Enumeration Type

GBFD-115501
GBFD-115701

AMR FR
TFO

Bit Field Type

GBFD-115502
GBFD-115701

AMR HR
TFO

Bit Field Type

GBFD-115507
GBFD-115701

WB AMR
TFO

Bit Field Type

GBFD-110501
GBFD-510502

Call Control
Handover Re-establishment

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111202

O&M of BTS

Bit Field Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-118201

Soft-Synchronized Network

Enumeration Type

GBFD-119204

Dynamically Adjusting the Uplink


MCS Coding

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Compound Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Compound Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-111202

O&M of BTS

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-115602

Acoustic Echo Cancellation(AEC)

Interval Type

GBFD-115602

Acoustic Echo Cancellation(AEC)

Interval Type

GBFD-115602

Acoustic Echo Cancellation(AEC)

Interval Type

GBFD-115602

Acoustic Echo Cancellation(AEC)

Interval Type

GBFD-115602

Acoustic Echo Cancellation(AEC)

Interval Type

GBFD-115602

Acoustic Echo Cancellation(AEC)

Enumeration Type

GBFD-115602

Acoustic Echo Cancellation(AEC)

Interval Type

GBFD-115602

Acoustic Echo Cancellation(AEC)

Interval Type

GBFD-115505

AMR Wireless Link Timer

Enumeration Type

GBFD-115505

AMR Wireless Link Timer

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

GBFD-115505

AMR Wireless Link Timer

Enumeration Type

GBFD-115505

AMR Wireless Link Timer

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

String Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-113801

TRX Cooperation

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-116401

End-to-End MS Signaling Tracing

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-118602

A over IP

Enumeration Type

GBFD-115601

Automatic Level Control (ALC)

Interval Type

GBFD-115601

Automatic Level Control (ALC)

Interval Type

GBFD-115601

Automatic Level Control (ALC)

Interval Type

GBFD-115601

Automatic Level Control (ALC)

Interval Type

GBFD-115601

Automatic Level Control (ALC)

Interval Type

GBFD-115601

Automatic Level Control (ALC)

Enumeration Type

GBFD-115601

Automatic Level Control (ALC)

Enumeration Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-113101

PDCH Dynamic Adjustment

Enumeration Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-119401

EDA(Extended Dynamic Allocation)

Enumeration Type

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-111803

A Interface Circuit Management

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-119115

Power Control

Enumeration Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

MRFD-210304

Faulty Management

Bit Field Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Enumeration Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Enumeration Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-510501

HUAWEI II Handover

Enumeration Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Enumeration Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Enumeration Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-115502

AMR HR

Enumeration Type

GBFD-115502

AMR HR

Interval Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Enumeration Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-115503

AMR Power Control

Interval Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-115703

Automatic Noise Compensation


(ANC)

Interval Type

GBFD-115703

Automatic Noise Compensation


(ANC)

Enumeration Type

GBFD-115703

Automatic Noise Compensation


(ANC)

Interval Type

MRFD-210602

Remote Electrical Tilt

String Type

GBFD-118601
GBFD-118602
GBFD-118605
GBFD-118611
GBFD-118622

Abis over IP
A over IP
IP QOS
Abis IP over E1/T1
A IP over E1/T1

Interval Type

None

None

Interval Type

MRFD-210304

Faulty Management

String Type

GBFD-115603

Automatic Noise Restraint (ANR)

Enumeration Type

GBFD-115603

Automatic Noise Restraint (ANR)

Interval Type

GBFD-115603

Automatic Noise Restraint (ANR)

Interval Type

GBFD-115603

Automatic Noise Restraint (ANR)

Enumeration Type

GBFD-115402
GBFD-118201

BSS-Based LCS (Cell ID + TA)


Soft-Synchronized Network

Interval Type

GBFD-510401
MRFD-210501

BTS GPS Synchronization


BTS/NodeB Clock

Interval Type

GBFD-510401
MRFD-210501

BTS GPS Synchronization


BTS/NodeB Clock

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210602

Remote Electrical Tilt

Interval Type

GBFD-510104

Multi-site Cell

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-118602

A over IP

Enumeration Type

GBFD-114701

Semi-Permanent Connection

Enumeration Type

GBFD-119904

PS Active Package Management

Interval Type

GBFD-119904

PS Active Package Management

Interval Type

GBFD-119904

PS Active Package Management

Interval Type

GBFD-119904

PS Active Package Management

Interval Type

GBFD-119904

PS Active Package Management

Interval Type

GBFD-119904

PS Active Package Management

Interval Type

GBFD-119904

PS Active Package Management

Enumeration Type

GBFD-119904

PS Active Package Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210401

BSC/RNC Software Management

Enumeration Type

MRFD-210401

BSC/RNC Software Management

Enumeration Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

MRFD-210304

Faulty Management

Bit Field Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-110502

Assignment and Immediate


Assignment

Enumeration Type

GBFD-110607

Direct Retry

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-110502

Assignment and Immediate


Assignment

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111203
GBFD-111803

O&M of BSC
A Interface Circuit Management

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-116901

Flex Ater

Enumeration Type

GBFD-116901

Flex Ater

Enumeration Type

GBFD-116901

Flex Ater

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-117701

BSC Local Switch

Interval Type

GBFD-111203

O&M of BSC

Bit Field Type

GBFD-114701

Semi-Permanent Connection

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-116902

Ater Compression Transmission

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111804

A Interface Protocol Process

Bit Field Type

GBFD-110302

IMSI Detach

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-118611

Abis IP over E1/T1

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

MRFD-210305

Security Management

Enumeration Type

GBFD-118611

Abis IP over E1/T1

String Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

String Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

String Type

GBFD-118611

Abis IP over E1/T1

String Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

String Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

String Type

GBFD-118611

Abis IP over E1/T1

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-118609

IP Fault Detection Based on BFD

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-115501

AMR FR

Enumeration Type

GBFD-115502

AMR HR

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210305

Security Management

Enumeration Type

MRFD-210305

Security Management

Interval Type

None

None

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

MRFD-210301

Configuration Management

String Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

String Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-114101

GPRS

Enumeration Type

None

None

String Type

GBFD-118609

IP Fault Detection Based on BFD

IP Address Type

GBFD-118609

IP Fault Detection Based on BFD

IP Address Type

GBFD-111605

Active Backup Power Control

Enumeration Type

GBFD-111605

Active Backup Power Control

Enumeration Type

GBFD-114401

Multi-band Sharing One BSC

Interval Type

GBFD-114401

Multi-band Sharing One BSC

Interval Type

GBFD-114401

Multi-band Sharing One BSC

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-111202

O&M of BTS

String Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-113725

BSC Node Redundancy

Interval Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Enumeration Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-111804
GBFD-111806

A Interface Protocol Process


STPSignaling Transport Point)

Enumeration Type

GBFD-113725

BSC Node Redundancy

Interval Type

GBFD-114201

EGPRS

Interval Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Enumeration Type

GBFD-510501

HUAWEI II Handover

Enumeration Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Interval Type

GBFD-113801

TRX Cooperation

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-510002

Gb Over FR

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-117802

Fast Ring Network Switch

Interval Type

GBFD-113602

Simplified Cell Broadcast

Any Type

GBFD-113602

Simplified Cell Broadcast

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-111003
GBFD-110301
GBFD-110303

Radio Common Channel


Management
Location Updating
Paging

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Enumeration Type

GBFD-111803
GBFD-113726

A Interface Circuit Management


TC Pool

Enumeration Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

IP Address Type

GBFD-118201

Soft-Synchronized Network

Compound Type

GBFD-118201

Soft-Synchronized Network

Compound Type

GBFD-116902
GBFD-118605
GBFD-113726

Ater Compression Transmission


IP QOS
TC Pool

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118601

Abis over IP

IP Address Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

IP Address Type

GBFD-117701

BSC Local Switch

Enumeration Type

GBFD-118621

Connection Inter BSC over IP

String Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

Interval Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-113726

TC Pool

Interval Type

GBFD-113726

TC Pool

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-110802

Pre-processing of Measurement
Report

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

GBFD-110303
GBFD-111003

Paging
Radio Common Channel
Management

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-117701
GBFD-117702

BSC Local Switch


BTS Local Switch

Enumeration Type

GBFD-117701
GBFD-117702

BSC Local Switch


BTS Local Switch

Enumeration Type

GBFD-119305
GBFD-119305

BSS Paging Coordination


BSS Paging Coordination

Enumeration Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

MRFD-210401

BSC/RNC Software Management

Enumeration Type

MRFD-210401

BSC/RNC Software Management

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210602

Remote Electrical Tilt

Enumeration Type

GBFD-111801

Ater Interface 4:1 Multiplexing

Enumeration Type

GBFD-111801
GBFD-113726

Ater Interface 4:1 Multiplexing


TC Pool

Enumeration Type

GBFD-111202
GBFD-111611

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

String Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-111202

O&M of BTS

String Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118401

Abis Transmission Optimization

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210602

Remote Electrical Tilt

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Enumeration Type

MRFD-210305

Security Management

Interval Type

GBFD-118601

Abis over IP

IP Address Type

GBFD-117702

BTS Local Switch

Enumeration Type

GBFD-118601

Abis over IP

IP Address Type

GBFD-110802

Pre-processing of Measurement
Report

Enumeration Type

GBFD-111202

O&M of BTS

String Type

GBFD-118401

Abis Transmission Optimization

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-111605

Active Backup Power Control

Enumeration Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-118103

Network Support SAIC

Enumeration Type

GBFD-111202

O&M of BTS

String Type

GBFD-118401

Abis Transmission Optimization

Interval Type

GBFD-510701

Compact BTS Automatic


Configuration and Planning

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-111207

BTS Test Function

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-117802

Fast Ring Network Switch

Interval Type

GBFD-118602

A over IP

Enumeration Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-114101

GPRS

Interval Type

GBFD-111202

O&M of BTS

String Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-110503

Call Reestablishment

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-113701
GBFD-111101

Frequency Hopping (RF hopping,


baseband hopping)
System Information Sending

Enumeration Type

GBFD-510702

Compact BTS Automatic Capacity


Planning

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118605

IP QOS

Enumeration Type

None

None

Enumeration Type

GBFD-110401
GBFD-110402

Basic Cell Selection


Basic Cell Re-selection

Enumeration Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

Interval Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

IP Address Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

Interval Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

Interval Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

Interval Type

GBFD-110401
GBFD-110301

Basic Cell Selection


Location Updating

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

Interval Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Interval Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210305

Security Management

Enumeration Type

GBFD-111003

Radio Common Channel


Management

Interval Type

GBFD-111003

Radio Common Channel


Management

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-118630

Ethernet OAM

Enumeration Type

GBFD-110607

Direct Retry

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-119115

Power Control

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

GBFD-111101
GBFD-114101

System Information Sending


GPRS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-211402

MBSC Load Balancing

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

String Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210602

Remote Electrical Tilt

Enumeration Type

GBFD-114402

Enhanced Dual-Band Network

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

MRFD-210301

Configuration Management

String Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-113001

SDCCH Dynamic Adjustment

Interval Type

MRFD-210301

Configuration Management

String Type

MRFD-211402

MBSC Load Balancing

String Type

GBFD-111202

O&M of BTS

String Type

MRFD-210301

Configuration Management

String Type

GBFD-118701

RAN Sharing

Enumeration Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Interval Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Interval Type

GBFD-111003

Radio Common Channel


Management

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-116201

Network-Controlled Cell Reselection


Enumeration Type
(NC2)

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-510803
GBFD-510804

Uplink EGPRS2-A
Downlink EGPRS2-A

Enumeration Type

GBFD-114325

Fast 3G Reselection at 2G CS Call


Release

Enumeration Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Interval Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

MRFD-210305

Security Management

String Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-510701

Compact BTS Automatic


Configuration and Planning

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Password Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Bit Field Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-510601

PICO Automatic Configuration and


Planning

Enumeration Type

GBFD-114101

GPRS

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

String Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-510103

Chain Cell Handover

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

None

None

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-113602

Simplified Cell Broadcast

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

None

None

Interval Type

GBFD-118605

IP QOS

Interval Type

MRFD-210206

Tree Topology

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118602

A over IP

Enumeration Type

GBFD-118602

A over IP

Enumeration Type

GBFD-118602

A over IP

Enumeration Type

GBFD-118609

IP Fault Detection Based on BFD

Enumeration Type

GBFD-111207

BTS Test Function

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111203

O&M of BSC

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111207

BTS Test Function

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

None

None

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-119301

Voice Fault Diagnosis

Interval Type

GBFD-119301

Voice Fault Diagnosis

Interval Type

GBFD-119301

Voice Fault Diagnosis

Enumeration Type

GBFD-119301

Voice Fault Diagnosis

Interval Type

GBFD-119301

Voice Fault Diagnosis

Interval Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-119403

Class11 DTM

Enumeration Type

GBFD-110501

Call Control

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

MRFD-210501

BTS/NodeB Clock

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210304

Faulty Management

Bit Field Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

String Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

String Type

GBFD-111203

O&M of BSC

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-113725

BSC Node Redundancy

Interval Type

GBFD-117401

MSC Pool

Interval Type

GBFD-119701

SGSN Pool

Interval Type

GBFD-117401

MSC Pool

Interval Type

MRFD-210403

License Management

Interval Type

GBFD-113725

BSC Node Redundancy

Enumeration Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-113602

Simplified Cell Broadcast

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Enumeration Type

GBFD-117602

Active Power Control

Interval Type

GBFD-111003
GBFD-110301
GBFD-110302

Radio Common Channel


Management
Location Updating
IMSI Detach

Bit Field Type

MRFD-210305

Security Management

Bit Field Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

MRFD-210206

Tree Topology

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-211402

MBSC Load Balancing

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Enumeration Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

GBFD-111207

BTS Test Function

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-110402
GBFD-110301
GBFD-110303

Basic Cell Re-selection


Location Updating
Paging

Enumeration Type

MRFD-210305

Security Management

String Type

MRFD-210305

Security Management

Enumeration Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Interval Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Interval Type

GBFD-110402

Basic Cell Re-selection

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Enumeration Type

GBFD-111203

O&M of BSC

Bit Field Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Bit Field Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111203

O&M of BSC

Bit Field Type

GBFD-118605

IP QOS

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

None

None

Enumeration Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210602

Remote Electrical Tilt

Interval Type

MRFD-210602

Remote Electrical Tilt

Interval Type

MRFD-210602

Remote Electrical Tilt

Interval Type

MRFD-210602

Remote Electrical Tilt

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

None

None

Interval Type

MRFD-210401

BSC/RNC Software Management

String Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110204
GBFD-119405
GBFD-110205

G3 Fax (TS61, TS62)


14.4kbit/s Circuit Switched Data
Bearer Service

Bit Field Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-114501

Co-BCCH Cell

Enumeration Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114402

Enhanced Dual-Band Network

String Type

GBFD-114402

Enhanced Dual-Band Network

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-113101

PDCH Dynamic Adjustment

Interval Type

GBFD-110501

Call Control

Interval Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

String Type

GBFD-111202

O&M of BTS

Enumeration Type

None

None

IP Address Type

None

None

IP Address Type

None

None

IP Address Type

None

None

Interval Type

GBFD-510701

Compact BTS Automatic


Configuration and Planning

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-211402

MBSC Load Balancing

Interval Type

MRFD-211402

MBSC Load Balancing

Interval Type

MRFD-211402

MBSC Load Balancing

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210602

Remote Electrical Tilt

String Type

MRFD-210602

Remote Electrical Tilt

Interval Type

None

None

IP Address Type

None

None

Enumeration Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-117401

MSC Pool

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

MRFD-210502

BSC/RNC Clock

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

IP Address Type

None

None

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-110608
GBFD-111005

SDCCH Handover
Enhanced Channel Assignment
Algorithm

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203
MRFD-210403

O&M of BSC
License Management

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-110607

Direct Retry

Enumeration Type

GBFD-110607

Direct Retry

Enumeration Type

GBFD-110601

HUAWEI I Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Enumeration Type

GBFD-510804

Downlink EGPRS2-A

Interval Type

GBFD-510804

Downlink EGPRS2-A

Interval Type

GBFD-114201

EGPRS

Interval Type

GBFD-115902

Transmit Diversity

Enumeration Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-119501

Adaptive Adjustment of Uplink and


Downlink Channels

Interval Type

GBFD-510802

Dual Carriers in Downlink

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115507

WB AMR

Interval Type

GBFD-115507

WB AMR

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Interval Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Interval Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Interval Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-115501
GBFD-510501
GBFD-110601

AMR FR
HUAWEI II Handover
HUAWEI I Handover

Interval Type

GBFD-115502
GBFD-510501
GBFD-110601

AMR HR
HUAWEI II Handover
HUAWEI I Handover

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-119203

Extended Uplink TBF

Interval Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Interval Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115507

WB AMR

Interval Type

GBFD-115507

WB AMR

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118620

Clock over IP support 1588V2

Interval Type

GBFD-119106

Coding Scheme

Enumeration Type

GBFD-114201
GBFD-119106
GBFD-114201
GBFD-119106

EGPRS
Coding Scheme
EGPRS
Coding Scheme

Enumeration Type

GBFD-510804

Downlink EGPRS2-A

Enumeration Type

GBFD-510804

Downlink EGPRS2-A

Enumeration Type

GBFD-114101
GBFD-119106
GBFD-114101
GBFD-119106

GPRS
Coding Scheme
GPRS
Coding Scheme

Enumeration Type

GBFD-114201
GBFD-119106
GBFD-114201
GBFD-119106

EGPRS
Coding Scheme
EGPRS
Coding Scheme

Enumeration Type

GBFD-110703
GBFD-117601

Enhanced Power Control Algorithm


HUAWEI III Power Control Algorithm

Enumeration Type

GBFD-110203

Point To Point Short Message Service


Enumeration Type
(TS21, TS22)

GBFD-114101

GPRS

Interval Type

GBFD-119106

Coding Scheme

Interval Type

GBFD-118901
GBFD-119106
GBFD-118901
GBFD-119106

CS-3/CS-4
Coding Scheme
CS-3/CS-4
Coding Scheme

Interval Type

GBFD-118901
GBFD-119106
GBFD-118901
GBFD-119106

CS-3/CS-4
Coding Scheme
CS-3/CS-4
Coding Scheme

Interval Type

GBFD-119106

Coding Scheme

Interval Type

GBFD-118901
GBFD-119106
GBFD-118901
GBFD-119106

CS-3/CS-4
Coding Scheme
CS-3/CS-4
Coding Scheme

Interval Type

GBFD-118901
GBFD-119106
GBFD-118901
GBFD-119106

CS-3/CS-4
Coding Scheme
CS-3/CS-4
Coding Scheme

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-117602

Active Power Control

Interval Type

GBFD-111804
GBFD-111806

A Interface Protocol Process


STPSignaling Transport Point)

Interval Type

GBFD-111804

A Interface Protocol Process

String Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-117401

MSC Pool

Interval Type

GBFD-111804
GBFD-111806

A Interface Protocol Process


STPSignaling Transport Point)

Enumeration Type

GBFD-111804
GBFD-118602
GBFD-118622

A Interface Protocol Process


A over IP
A IP over E1/T1

Interval Type

MRFD-211402

MBSC Load Balancing

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

None

None

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

GBFD-111605

Active Backup Power Control

Interval Type

GBFD-111605

Active Backup Power Control

Interval Type

GBFD-111605

Active Backup Power Control

Interval Type

GBFD-113602

Simplified Cell Broadcast

Enumeration Type

GBFD-114802

Discontinuous Reception (DRX)

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

None

None

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-114101

GPRS

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Enumeration Type

GBFD-111202

O&M of BTS

String Type

GBFD-118601

Abis over IP

IP Address Type

GBFD-118609

IP Fault Detection Based on BFD

IP Address Type

None

None

IP Address Type

GBFD-118601

Abis over IP

IP Address Type

None

None

IP Address Type

None

None

Interval Type

None

None

Bit Field Type

GBFD-110607

Direct Retry

Interval Type

GBFD-510301

Public Voice Group Call Service

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-113521

A5/1 Encryption Flow Optimization

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-111207

BTS Test Function

Interval Type

GBFD-111207

BTS Test Function

Interval Type

GBFD-111207

BTS Test Function

Interval Type

GBFD-111207

BTS Test Function

Interval Type

GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501
GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501

GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels
GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-113101

PDCH Dynamic Adjustment

Interval Type

GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501
GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501

GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels
GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Enumeration Type

GBFD-114101
GBFD-113101
GBFD-114101
GBFD-113101

GPRS
PDCH Dynamic Adjustment
GPRS
PDCH Dynamic Adjustment

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Enumeration Type

GBFD-118101

Dynamic Transmit Diversity

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118401

Abis Transmission Optimization

Interval Type

GBFD-111207

BTS Test Function

Enumeration Type

MRFD-210501

BTS/NodeB Clock

Interval Type

None

None

Interval Type

MRFD-211501

IP-Based 2G/3G Co-Transmission on


Base Station Side

Interval Type

MRFD-210501

BTS/NodeB Clock

Enumeration Type

GBFD-118605

IP QOS

IP Address Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-111101

System Information Sending

Enumeration Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Compound Type

MRFD-210304

Faulty Management

Compound Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111202

O&M of BTS

Compound Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114201

EGPRS

Enumeration Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-119201

11-Bit EGPRS Access

Enumeration Type

GBFD-510803
GBFD-510804

Uplink EGPRS2-A
Downlink EGPRS2-A

Enumeration Type

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Enumeration Type

GBFD-110202
GBFD-110521

Emergency Call Service (TS12)


Guaranteed Emergency Call

Interval Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

None

None

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

GBFD-510307

Group Call EMLPP

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Enumeration Type

GBFD-111202

O&M of BTS

IP Address Type

GBFD-510309

Group Call Reliability Enhancing

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-113501
GBFD-113503

A5/1 and A5/2 Ciphering Algorithm


A5/3 Ciphering Algorithm

Bit Field Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-116401

End-to-End MS Signaling Tracing

Enumeration Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Compound Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111801

Ater Interface 4:1 Multiplexing

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Enumeration Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113402

Dynamic Adjustment Between FR


and HR

Enumeration Type

GBFD-118602

A over IP

Enumeration Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-115704

Enhancement Packet Loss


Concealment(EPLC)

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Interval Type

GBFD-110202

Emergency Call Service (TS12)

Enumeration Type

GBFD-118630

Ethernet OAM

Enumeration Type

GBFD-118630

Ethernet OAM

Enumeration Type

None

None

Interval Type

None

None

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-110502

Assignment and Immediate


Assignment

Interval Type

GBFD-115403

Simple Mode LCS(Cell ID + TA)

Enumeration Type

GBFD-117802

Fast Ring Network Switch

Interval Type

MRFD-210304

Faulty Management

Compound Type

MRFD-210304

Faulty Management

Compound Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Compound Type

GBFD-113602

Simplified Cell Broadcast

Compound Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Compound Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Compound Type

GBFD-111202

O&M of BTS

Compound Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Compound Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Enumeration Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Enumeration Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-117602

Active Power Control

Interval Type

GBFD-117602

Active Power Control

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111202

O&M of BTS

String Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111202

O&M of BTS

String Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

String Type

GBFD-114001

Extended Cell

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Enumeration Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Enumeration Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Enumeration Type

GBFD-114001

Extended Cell

Enumeration Type

GBFD-119203

Extended Uplink TBF

Enumeration Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Interval Type

GBFD-510307

Group Call EMLPP

Enumeration Type

GBFD-510307

Group Call EMLPP

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-110502

Assignment and Immediate


Assignment

Interval Type

GBFD-117802

Fast Ring Network Switch

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

None

None

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

MRFD-211503

2G/3G Co-Transmission Resources


Management on MBSC

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-510701

Compact BTS Automatic


Configuration and Planning

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

MRFD-210103

Link aggregation

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301
GBFD-110801
GBFD-110802

GSM/WCDMA Interoperability
Processing of Measurement Report
Pre-processing of Measurement
Report

Enumeration Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Enumeration Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Interval Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Interval Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Interval Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Interval Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Interval Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Interval Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Interval Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Enumeration Type

GBFD-111203
MRFD-210401

O&M of BSC
BSC/RNC Software Management

String Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

String Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

String Type

MRFD-210301

Configuration Management

String Type

GBFD-111203
MRFD-210304

O&M of BSC
Faulty Management

Enumeration Type

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-117601

HUAWEI III Power Control Algorithm

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-117301

Flex Abis

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-117301

Flex Abis

Enumeration Type

GBFD-117001

Flex MAIO

Enumeration Type

GBFD-113521
GBFD-118201
GBFD-117001

A5/1 Encryption Flow Optimization


Soft-Synchronized Network
Flex MAIO

Enumeration Type

GBFD-119501

Adaptive Adjustment of Uplink and


Downlink Channels

Interval Type

GBFD-119501

Adaptive Adjustment of Uplink and


Downlink Channels

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-118605
MRFD-211503

IP QOS
2G/3G Co-Transmission Resources
Management on MBSC

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111003
GBFD-111101

Radio Common Channel


Management
System Information Sending

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210301

Configuration Management

String Type

MRFD-210303

Inventory Management

String Type

MRFD-210403

License Management

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203
MRFD-210401

O&M of BSC
BSC/RNC Software Management

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-113101
GBFD-114201
GBFD-119303
GBFD-119501

PDCH Dynamic Adjustment


EGPRS
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Enumeration Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-115601

Automatic Level Control (ALC)

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-110501
GBFD-113301

Call Control
Enhanced Full Rate

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

None

None

Interval Type

GBFD-510702
GBFD-510607

Compact BTS Automatic Capacity


Planning

Enumeration Type

GBFD-510601

PICO Automatic Configuration and


Planning

Enumeration Type

GBFD-510701

Compact BTS Automatic


Configuration and Planning

Enumeration Type

GBFD-118604
GBFD-118610

Abis MUX
UDP MUX for A Transmission

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-114801
GBFD-115501

Discontinuous Transmission (DTX)


Downlink
AMR FR

Enumeration Type

GBFD-110101

Frequency Band

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-110101

Frequency Band

Interval Type

GBFD-510101

AFC(Automatic Frequency
Correction)

Enumeration Type

GBFD-510101

AFC(Automatic Frequency
Correction)

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-112401

Cell Frequency Scan

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

String Type

GBFD-112401

Cell Frequency Scan

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-114803
GBFD-115501

Discontinuous Transmission (DTX)


Uplink
AMR FR

Enumeration Type

GBFD-510701

Compact BTS Automatic


Configuration and Planning

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-510701

Compact BTS Automatic


Configuration and Planning

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

None

None

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-118602

A over IP

Enumeration Type

GBFD-119115

Power Control

Interval Type

GBFD-118201

Soft-Synchronized Network

Compound Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Compound Type

GBFD-119901

Streaming QoS(GBR)

Enumeration Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Enumeration Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Enumeration Type

GBFD-510307

Group Call EMLPP

Enumeration Type

None

None

Enumeration Type

GBFD-114101

GPRS

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111101
GBFD-114101

System Information Sending


GPRS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-114201

EGPRS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-114101

GPRS

Enumeration Type

GBFD-510401
MRFD-210501

BTS GPS Synchronization


BTS/NodeB Clock

Enumeration Type

MRFD-210502

BSC/RNC Clock

Interval Type

GBFD-116001

Resource Reservation

Enumeration Type

GBFD-510309

Group Call Reliability Enhancing

Interval Type

GBFD-510309

Group Call Reliability Enhancing

Interval Type

GBFD-113725

BSC Node Redundancy

Interval Type

GBFD-113725

BSC Node Redundancy

String Type

GBFD-117301

Flex Abis

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-113602

Simplified Cell Broadcast

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-114401

Multi-band Sharing One BSC

Interval Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Enumeration Type

GBFD-111202

O&M of BTS

Bit Field Type

GBFD-118601

Abis over IP

IP Address Type

GBFD-118601

Abis over IP

IP Address Type

GBFD-113401

Half Rate Speech

Enumeration Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-118602

A over IP

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-110101

Frequency Band

Enumeration Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Interval Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

MRFD-210305

Security Management

Interval Type

GBFD-119404

HMC DTM

Enumeration Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-118701

RAN Sharing

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

String Type

GBFD-110601

HUAWEI I Handover

Enumeration Type

GBFD-510103

Chain Cell Handover

Enumeration Type

GBFD-510103

Chain Cell Handover

Interval Type

GBFD-510103

Chain Cell Handover

Interval Type

GBFD-510102

Fast Move Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

GBFD-510102

Fast Move Handover

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Enumeration Type

GBFD-117101

BTS power lift for handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Enumeration Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-510102

Fast Move Handover

Interval Type

GBFD-113725

BSC Node Redundancy

Enumeration Type

GBFD-113725

BSC Node Redundancy

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-510102

Fast Move Handover

Interval Type

GBFD-113703

Antenna Frequency Hopping

Enumeration Type

GBFD-113703

Antenna Frequency Hopping

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-116001

Resource Reservation

Interval Type

GBFD-111202
GBFD-111601

O&M of BTS
BTS Power Management

Enumeration Type

GBFD-111202
GBFD-111601

O&M of BTS
BTS Power Management

Interval Type

GBFD-113401
GBFD-111101

Half Rate Speech


System Information Sending

Enumeration Type

GBFD-114801
GBFD-113401
GBFD-115502

Discontinuous Transmission (DTX)


Downlink
Half Rate Speech
AMR HR

Enumeration Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-114803
GBFD-113401
GBFD-115502

Discontinuous Transmission (DTX)


Uplink
Half Rate Speech
AMR HR

Enumeration Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-117001

Flex MAIO

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Enumeration Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111207

BTS Test Function

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-111604

Intelligent Combiner Bypass

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118602

A over IP

Interval Type

None

None

Interval Type

GBFD-113001

SDCCH Dynamic Adjustment

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-211402

MBSC Load Balancing

Enumeration Type

None

None

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-114701

Semi-Permanent Connection

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-510102

Fast Move Handover

Interval Type

GBFD-111203

O&M of BSC

String Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-110502

Assignment and Immediate


Assignment

Enumeration Type

GBFD-119202

Packet Assignment Taken Over by


the BTS

Enumeration Type

GBFD-110502

Assignment and Immediate


Assignment

Enumeration Type

GBFD-110502

Assignment and Immediate


Assignment

Interval Type

GBFD-110502

Assignment and Immediate


Assignment

Interval Type

GBFD-110502

Assignment and Immediate


Assignment

Enumeration Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-118201

Soft-Synchronized Network

Enumeration Type

GBFD-110502

Assignment and Immediate


Assignment

Interval Type

GBFD-114101

GPRS

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-115504

AMR FR/HR Dynamic Adjustment

Interval Type

GBFD-115504

AMR FR/HR Dynamic Adjustment

Interval Type

MRFD-211402

MBSC Load Balancing

Bit Field Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-115504

AMR FR/HR Dynamic Adjustment

Interval Type

GBFD-115504

AMR FR/HR Dynamic Adjustment

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115507

WB AMR

Interval Type

GBFD-114701

Semi-Permanent Connection

Bit Field Type

GBFD-114402

Enhanced Dual-Band Network

Enumeration Type

GBFD-114402

Enhanced Dual-Band Network

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

String Type

GBFD-114402

Enhanced Dual-Band Network

Enumeration Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Enumeration Type

GBFD-110608

SDCCH Handover

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-113602

Simplified Cell Broadcast

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-112401

Cell Frequency Scan

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-111001
GBFD-111005

TRX Management
Enhanced Channel Assignment
Algorithm

Interval Type

GBFD-111001
GBFD-111005

TRX Management
Enhanced Channel Assignment
Algorithm

Interval Type

GBFD-111001
GBFD-111005

TRX Management
Enhanced Channel Assignment
Algorithm

Interval Type

GBFD-111001
GBFD-111005

TRX Management
Enhanced Channel Assignment
Algorithm

Interval Type

GBFD-111001
GBFD-111005

TRX Management
Enhanced Channel Assignment
Algorithm

Interval Type

GBFD-111001
GBFD-111005

TRX Management
Enhanced Channel Assignment
Algorithm

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-511104

GSM and UMTS Traffic Steering


Based on Iur-g

Enumeration Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Enumeration Type

MRFD-211404

MBSC Handover based on Load


Enhancement

Enumeration Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Enumeration Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Enumeration Type

None

None

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Interval Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-115504

AMR FR/HR Dynamic Adjustment

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-211402

MBSC Load Balancing

Enumeration Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Enumeration Type

GBFD-118601

Abis over IP

IP Address Type

MRFD-210301

Configuration Management

IP Address Type

GBFD-118603

Gb over IP

IP Address Type

GBFD-118603

Gb over IP

IP Address Type

GBFD-111203
MRFD-210403

O&M of BSC
License Management

IP Address Type

GBFD-111202

O&M of BTS

IP Address Type

GBFD-118611
GBFD-118622
MRFD-211502

Abis IP over E1/T1


A IP over E1/T1
IP-Based 2G/3G Co-Transmission on
MBSC Side

IP Address Type

GBFD-118603

Gb over IP

IP Address Type

GBFD-118605

IP QOS

IP Address Type

MRFD-211502

IP-Based 2G/3G Co-Transmission on


MBSC Side

IP Address Type

None

None

IP Address Type

None

None

IP Address Type

None

None

IP Address Type

GBFD-118606

Clock over IP

IP Address Type

GBFD-118603

Gb over IP

IP Address Type

GBFD-118606

Clock over IP

IP Address Type

GBFD-118603

Gb over IP

IP Address Type

GBFD-118603

Gb over IP

IP Address Type

GBFD-118603

Gb over IP

IP Address Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

MRFD-210103

Link aggregation

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

None

None

Interval Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Enumeration Type

GBFD-510103

Chain Cell Handover

Enumeration Type

GBFD-118606

Clock over IP

Enumeration Type

GBFD-118606

Clock over IP

Enumeration Type

GBFD-117801

Ring Topology

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-114201

EGPRS

Enumeration Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-113726

TC Pool

Enumeration Type

GBFD-510104

Multi-site Cell

Enumeration Type

GBFD-116201

Network-Controlled Cell Reselection


Enumeration Type
(NC2)

GBFD-118603

Gb over IP

Enumeration Type

None

None

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-117803

Abis Transmission Backup

Enumeration Type

GBFD-117702

BTS Local Switch

Enumeration Type

GBFD-113726

TC Pool

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202
GBFD-117804

O&M of BTS
Intelligent Shutdown of TRX Due to
PSU Failure

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-113101
GBFD-113201
GBFD-119303
GBFD-119501

PDCH Dynamic Adjustment


Concentric Cell
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201
GBFD-114402

Concentric Cell
Enhanced Dual-Band Network

Enumeration Type

GBFD-118630

Ethernet OAM

Enumeration Type

GBFD-118604
GBFD-118610

Abis MUX
UDP MUX for A Transmission

Enumeration Type

None

None

String Type

None

None

String Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

String Type

None

None

String Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

String Type

None

None

String Type

None

None

Enumeration Type

GBFD-118401

Abis Transmission Optimization

Enumeration Type

GBFD-111612

Multi-Carrier Intelligent Voltage


Regulation

Interval Type

GBFD-118601

Abis over IP

Enumeration Type

None

None

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

None

None

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-510702

Compact BTS Automatic Capacity


Planning

Interval Type

GBFD-111701

Board Switchover

Enumeration Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

String Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

MRFD-210502

BSC/RNC Clock

String Type

MRFD-210103

Link aggregation

Interval Type

None

None

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601

HUAWEI I Handover

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-118601
GBFD-117301

Abis over IP
Flex Abis

Enumeration Type

GBFD-118601
GBFD-117301

Abis over IP
Flex Abis

Enumeration Type

GBFD-118601
GBFD-117301

Abis over IP
Flex Abis

Enumeration Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Interval Type

GBFD-118605

IP QOS

Interval Type

None

None

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111203

O&M of BSC

Interval Type

None

None

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

MRFD-210301

Configuration Management

String Type

MRFD-210304

Faulty Management

String Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

None

None

Enumeration Type

GBFD-114701

Semi-Permanent Connection

Enumeration Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-118602

A over IP

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-117401

MSC Pool

Enumeration Type

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-111202

O&M of BTS

Interval Type

GBFD-110601

HUAWEI I Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-116201

Network-Controlled Cell Reselection


Enumeration Type
(NC2)

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-116201
GBFD-114301
GBFD-114322

Network-Controlled Cell Reselection


(NC2)
Interval Type
GSM/WCDMA Interoperability
GSM/WCDMA Load Based Handover

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-110601

HUAWEI I Handover

Enumeration Type

None

None

Enumeration Type

GBFD-113725

BSC Node Redundancy

Interval Type

GBFD-118611

Abis IP over E1/T1

IP Address Type

GBFD-118611

Abis IP over E1/T1

IP Address Type

None

None

IP Address Type

GBFD-111202

O&M of BTS

IP Address Type

GBFD-118603

Gb over IP

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-510104

Multi-site Cell

Interval Type

GBFD-510104

Multi-site Cell

Interval Type

MRFD-210304

Faulty Management

String Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

IP Address Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

IP Address Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

None

None

Enumeration Type

None

None

Interval Type

None

None

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111203

O&M of BSC

Bit Field Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

String Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

GBFD-115402

BSS-Based LCS (Cell ID + TA)

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

MRFD-210502

BSC/RNC Clock

String Type

MRFD-210301

Configuration Management

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

None

None

Interval Type

GBFD-117301

Flex Abis

Enumeration Type

GBFD-117301

Flex Abis

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118605

IP QOS

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-118605

IP QOS

Interval Type

None

None

Enumeration Type

GBFD-114201

EGPRS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118601
GBFD-117301

Abis over IP
Flex Abis

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210401

BSC/RNC Software Management

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Interval Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Interval Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Interval Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Interval Type

GBFD-119301

Voice Fault Diagnosis

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202
GBFD-111601

O&M of BTS
BTS Power Management

Enumeration Type

GBFD-118602

A over IP

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Enumeration Type

None

None

Interval Type

GBFD-111609

Enhanced BCCH Power Consumption


Enumeration Type
Optimization

GBFD-111609

Enhanced BCCH Power Consumption


Enumeration Type
Optimization

GBFD-111609

Enhanced BCCH Power Consumption


Compound Type
Optimization

GBFD-111609

Enhanced BCCH Power Consumption


Interval Type
Optimization

GBFD-111609

Enhanced BCCH Power Consumption


Compound Type
Optimization

GBFD-118601

Abis over IP

String Type

GBFD-118630

Ethernet OAM

String Type

GBFD-510104

Multi-site Cell

Interval Type

MRFD-210206

Tree Topology

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

GBFD-118630
MRFD-210301

Ethernet OAM
Configuration Management

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-118611

Abis IP over E1/T1

IP Address Type

GBFD-118611

Abis IP over E1/T1

IP Address Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

IP Address Type

GBFD-118601

Abis over IP

IP Address Type

GBFD-118630

Ethernet OAM

IP Address Type

None

None

IP Address Type

None

None

IP Address Type

None

None

IP Address Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

IP Address Type

GBFD-118606

Clock over IP

IP Address Type

GBFD-118606

Clock over IP

IP Address Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-118609
MRFD-210103

IP Fault Detection Based on BFD


Link aggregation

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-111605

Active Backup Power Control

Interval Type

GBFD-510701
GBFD-510601

Compact BTS Automatic


Configuration and Planning
PICO Automatic Configuration and
Planning

Interval Type

GBFD-510702

Compact BTS Automatic Capacity


Planning

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118604
GBFD-118610

Abis MUX
UDP MUX for A Transmission

Interval Type

MRFD-210305

Security Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-113101

PDCH Dynamic Adjustment

Interval Type

GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501
GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501

GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels
GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Interval Type

GBFD-114101

GPRS

Interval Type

MRFD-210305

Security Management

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-119110

Access

Enumeration Type

GBFD-119110

Access

Enumeration Type

GBFD-119110

Access

Enumeration Type

GBFD-119110

Access

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110901
GBFD-114001

Adjustment of Adaptive Timing


Advance
Extended Cell

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Enumeration Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

GBFD-117301

Flex Abis

Interval Type

None

None

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

MRFD-210305

Security Management

Interval Type

None

None

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

IP Address Type

GBFD-114401
GBFD-111101

Multi-band Sharing One BSC


System Information Sending

Interval Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Interval Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

String Type

MRFD-210301

Configuration Management

String Type

GBFD-510702

Compact BTS Automatic Capacity


Planning

String Type

GBFD-118611

Abis IP over E1/T1

Interval Type

None

None

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111202

O&M of BTS

String Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

None

None

Interval Type

GBFD-118630
MRFD-210301

Ethernet OAM
Configuration Management

Interval Type

GBFD-118630

Ethernet OAM

String Type

GBFD-118630
MRFD-210301

Ethernet OAM
Configuration Management

String Type

GBFD-119102

Packet System Information

Enumeration Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-117501
GBFD-110801
GBFD-110802

Enhanced Measurement
Report(EMR)
Processing of Measurement Report
Pre-processing of Measurement
Report

Enumeration Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-118630
MRFD-210301

Ethernet OAM
Configuration Management

Interval Type

GBFD-118630

Ethernet OAM

Enumeration Type

GBFD-118611

Abis IP over E1/T1

Enumeration Type

GBFD-118630

Ethernet OAM

Enumeration Type

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-114301

GSM/WCDMA Interoperability

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

GBFD-110607

Direct Retry

Interval Type

GBFD-113001

SDCCH Dynamic Adjustment

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

None

None

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

None

None

Interval Type

None

None

Enumeration Type

MRFD-210301

Configuration Management

String Type

GBFD-510702

Compact BTS Automatic Capacity


Planning

String Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Enumeration Type

GBFD-111701

Board Switchover

Enumeration Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-111202
GBFD-111211

O&M of BTS
Reporting the Temperature List of
the BTS Equipment Room

Enumeration Type

GBFD-111202
GBFD-111211

O&M of BTS
Reporting the Temperature List of
the BTS Equipment Room

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-510102

Fast Move Handover

Interval Type

GBFD-118611

Abis IP over E1/T1

Interval Type

GBFD-118611

Abis IP over E1/T1

Interval Type

GBFD-118611

Abis IP over E1/T1

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

None

None

Interval Type

GBFD-111301

LAPD Multiplexing at Abis Interface

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118611

Abis IP over E1/T1

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-110802

Pre-processing of Measurement
Report

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-110501

Call Control

Enumeration Type

GBFD-117401

MSC Pool

Interval Type

GBFD-117401

MSC Pool

Interval Type

GBFD-117401

MSC Pool

Interval Type

GBFD-117401

MSC Pool

Enumeration Type

GBFD-117401

MSC Pool

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-110503

Call Reestablishment

Interval Type

GBFD-111203

O&M of BSC

String Type

GBFD-117701
GBFD-117702

BSC Local Switch


BTS Local Switch

String Type

GBFD-117701
GBFD-117702

BSC Local Switch


BTS Local Switch

String Type

GBFD-117701
GBFD-117702

BSC Local Switch


BTS Local Switch

String Type

GBFD-117701
GBFD-117702

BSC Local Switch


BTS Local Switch

String Type

GBFD-117701
GBFD-117702

BSC Local Switch


BTS Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117701

BSC Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-117702

BTS Local Switch

String Type

GBFD-510102

Fast Move Handover

Enumeration Type

GBFD-111003
GBFD-110301
GBFD-110303
GBFD-110502

Radio Common Channel


Management
Location Updating
Paging
Assignment and Immediate
Assignment

Enumeration Type

GBFD-111701

Board Switchover

Enumeration Type

GBFD-510801

MSRD

Enumeration Type

GBFD-510801

MSRD

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-119001

Gb Interface Function

Interval Type

GBFD-113725

BSC Node Redundancy

Interval Type

GBFD-114101

GPRS

Interval Type

None

None

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

None

None

Enumeration Type

GBFD-111804

A Interface Protocol Process

Interval Type

None

None

Enumeration Type

GBFD-118602

A over IP

Interval Type

GBFD-118611

Abis IP over E1/T1

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

None

None

Interval Type

GBFD-118604
GBFD-118610

Abis MUX
UDP MUX for A Transmission

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118604
GBFD-118610

Abis MUX
UDP MUX for A Transmission

Interval Type

GBFD-117801

Ring Topology

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Enumeration Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-114101
GBFD-119205

GPRS
Dynamically Adjusting the RRBP
Frequency

Interval Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-116301
GBFD-119502

Network Assisted Cell Change


(NACC)
PS Handover

Enumeration Type

GBFD-111804

A Interface Protocol Process

String Type

GBFD-111804

A Interface Protocol Process

String Type

GBFD-111804

A Interface Protocol Process

String Type

GBFD-111804

A Interface Protocol Process

String Type

GBFD-111804

A Interface Protocol Process

String Type

GBFD-118602

A over IP

String Type

GBFD-118602

A over IP

String Type

GBFD-118602

A over IP

String Type

GBFD-118602

A over IP

String Type

GBFD-118602

A over IP

String Type

GBFD-114101

GPRS

String Type

GBFD-118605

IP QOS

String Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-119115

Power Control

Interval Type

GBFD-115501
GBFD-115502
GBFD-115701
GBFD-113301
GBFD-113726

AMR FR
AMR HR
TFO
Enhanced Full Rate
TC Pool

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

String Type

MRFD-210301

Configuration Management

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

String Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

String Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

String Type

GBFD-510704
GBFD-510601

PICO Automatic Configuration and


Planning

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

String Type

MRFD-210301

Configuration Management

String Type

GBFD-116201
GBFD-116301

Network-Controlled Cell Reselection


(NC2)
Enumeration Type
Network Assisted Cell Change
(NACC)

GBFD-116201

Network-Controlled Cell Reselection


Enumeration Type
(NC2)

GBFD-116201
GBFD-119502

Network-Controlled Cell Reselection


(NC2)
Enumeration Type
PS Handover

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-110401
GBFD-110402
GBFD-111101

Basic Cell Selection


Basic Cell Re-selection
System Information Sending

Bit Field Type

GBFD-110801
GBFD-110802

Processing of Measurement Report


Pre-processing of Measurement
Report

Interval Type

GBFD-510102

Fast Move Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Interval Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Interval Type

GBFD-119107
GBFD-114302
GBFD-119502
GBFD-111101

Networking Control Mode


GSM/TD-SCDMA Interoperability
PS Handover
System Information Sending

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

MRFD-210301

Configuration Management

IP Address Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-118611

Abis IP over E1/T1

IP Address Type

None

None

IP Address Type

None

None

IP Address Type

None

None

IP Address Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

MRFD-210401

BSC/RNC Software Management

String Type

GBFD-119108
GBFD-114151

Network Operation Mode Support


DTM

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-510501

HUAWEI II Handover

Enumeration Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Enumeration Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-116902
GBFD-118605
GBFD-113726

Ater Compression Transmission


IP QOS
TC Pool

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Enumeration Type

GBFD-119107

Networking Control Mode

Enumeration Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

GBFD-116201

Network-Controlled Cell Reselection


Enumeration Type
(NC2)

GBFD-111202

O&M of BTS

Interval Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-510309

Group Call Reliability Enhancing

Interval Type

None

None

Interval Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Interval Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Interval Type

GBFD-117401
GBFD-119701

MSC Pool
SGSN Pool

Interval Type

GBFD-119701

SGSN Pool

Interval Type

GBFD-111101

System Information Sending

Enumeration Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-115402
GBFD-118201

BSS-Based LCS (Cell ID + TA)


Soft-Synchronized Network

Enumeration Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-510301

Public Voice Group Call Service

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118611
GBFD-118622
GBFD-111202

Abis IP over E1/T1


A IP over E1/T1
O&M of BTS

Interval Type

GBFD-118611
GBFD-118622
GBFD-111202

Abis IP over E1/T1


A IP over E1/T1
O&M of BTS

Interval Type

GBFD-118605
GBFD-111202

IP QOS
O&M of BTS

Interval Type

GBFD-111202
MRFD-210103

O&M of BTS
Link aggregation

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202
MRFD-210103

O&M of BTS
Link aggregation

Enumeration Type

GBFD-111207

BTS Test Function

Enumeration Type

MRFD-210602

Remote Electrical Tilt

Enumeration Type

None

None

Interval Type

GBFD-111203

O&M of BSC

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-119901

Streaming QoS(GBR)

Enumeration Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-113728

OML Backup

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-116601

Abis Bypass

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

None

None

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-111202

O&M of BTS

IP Address Type

GBFD-111202

O&M of BTS

IP Address Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

String Type

MRFD-210301
GBFD-118701

Configuration Management
RAN Sharing

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-118701

RAN Sharing

Enumeration Type

GBFD-118701

RAN Sharing

Interval Type

GBFD-118701

RAN Sharing

Bit Field Type

GBFD-111803

A Interface Circuit Management

Enumeration Type

GBFD-111803

A Interface Circuit Management

Enumeration Type

GBFD-111801

Ater Interface 4:1 Multiplexing

Enumeration Type

MRFD-210401

BSC/RNC Software Management

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-118701

RAN Sharing

String Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-211402

MBSC Load Balancing

Interval Type

MRFD-211501

IP-Based 2G/3G Co-Transmission on


Base Station Side

Interval Type

MRFD-210401

BSC/RNC Software Management

Enumeration Type

GBFD-110101

Frequency Band

String Type

GBFD-114201

EGPRS

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Enumeration Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-114701

Semi-Permanent Connection

Bit Field Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-510104

Multi-site Cell

Interval Type

GBFD-510104

Multi-site Cell

Interval Type

GBFD-510104

Multi-site Cell

Enumeration Type

GBFD-114402

Enhanced Dual-Band Network

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Enumeration Type

GBFD-114321

GSM/WCDMA Service Based


Handover

Enumeration Type

GBFD-114321

GSM/WCDMA Service Based


Handover

Enumeration Type

MRFD-211402

MBSC Load Balancing

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

GBFD-111003

Radio Common Channel


Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111612

Multi-Carrier Intelligent Voltage


Regulation

Enumeration Type

GBFD-119202

Packet Assignment Taken Over by


the BTS

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-110303

Paging

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-110303

Paging

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118601
GBFD-118602
GBFD-118605
GBFD-118611
GBFD-118622

Abis over IP
A over IP
IP QOS
Abis IP over E1/T1
A IP over E1/T1

Interval Type

None

None

Interval Type

GBFD-117602

Active Power Control

Interval Type

GBFD-510501

HUAWEI II Handover

Enumeration Type

GBFD-118601
GBFD-118602
GBFD-118605
GBFD-118611
GBFD-118622

Abis over IP
A over IP
IP QOS
Abis IP over E1/T1
A IP over E1/T1

Enumeration Type

MRFD-210401

BSC/RNC Software Management

Enumeration Type

GBFD-119115

Power Control

Enumeration Type

GBFD-110601

HUAWEI I Handover

Enumeration Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-110601

HUAWEI I Handover

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-119115

Power Control

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111202
GBFD-117301

O&M of BTS
Flex Abis

Enumeration Type

GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501
GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501

GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels
GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Interval Type

GBFD-111606

Power Optimization Based on


Channel Type

Enumeration Type

GBFD-113101
GBFD-119303
GBFD-119501

PDCH Dynamic Adjustment


Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Enumeration Type

GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501
GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501

GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels
GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Interval Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-113725

BSC Node Redundancy

Interval Type

GBFD-118601
GBFD-113725

Abis over IP
BSC Node Redundancy

IP Address Type

GBFD-118601
GBFD-113725

Abis over IP
BSC Node Redundancy

IP Address Type

GBFD-118601
GBFD-113725

Abis over IP
BSC Node Redundancy

Interval Type

GBFD-118611

Abis IP over E1/T1

IP Address Type

GBFD-118611

Abis IP over E1/T1

IP Address Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

IP Address Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

IP Address Type

GBFD-118609

IP Fault Detection Based on BFD

IP Address Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

IP Address Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

IP Address Type

GBFD-118605

IP QOS

IP Address Type

GBFD-118601
GBFD-118602
GBFD-118605
GBFD-118611
GBFD-118622

Abis over IP
A over IP
IP QOS
Abis IP over E1/T1
A IP over E1/T1

IP Address Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Interval Type

GBFD-111202

O&M of BTS

String Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118611

Abis IP over E1/T1

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

GBFD-119901

Streaming QoS(GBR)

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-118604
GBFD-118610

Abis MUX
UDP MUX for A Transmission

Bit Field Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-110402
GBFD-111101

Basic Cell Re-selection


System Information Sending

Enumeration Type

MRFD-210305

Security Management

Enumeration Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-118630

Ethernet OAM

Interval Type

None

None

Interval Type

GBFD-118604

Abis MUX

Interval Type

GBFD-119801

Packet SI Status

Enumeration Type

GBFD-118630

Ethernet OAM

Interval Type

None

None

Interval Type

GBFD-119110

Access

Enumeration Type

GBFD-114201

EGPRS

Interval Type

GBFD-119110

Access

Enumeration Type

GBFD-119110

Access

Enumeration Type

GBFD-114201

EGPRS

Interval Type

GBFD-119110

Access

Enumeration Type

GBFD-114201

EGPRS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-110303

Paging

Interval Type

GBFD-110303

Paging

Interval Type

GBFD-110303

Paging

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111801

Ater Interface 4:1 Multiplexing

Interval Type

GBFD-111701

Board Switchover

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-119905

PoC QoS

Interval Type

GBFD-119905

PoC QoS

Interval Type

GBFD-119905

PoC QoS

Interval Type

GBFD-119905

PoC QoS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210301

Configuration Management

String Type

MRFD-210301

Configuration Management

String Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-113728

OML Backup

Interval Type

GBFD-117801

Ring Topology

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

None

None

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-118630

Ethernet OAM

Enumeration Type

MRFD-211501

IP-Based 2G/3G Co-Transmission on


Base Station Side

Enumeration Type

GBFD-114323

2G/3G Cell Reselection Based on MS


Enumeration Type
State

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-510804

Downlink EGPRS2-A

Interval Type

GBFD-510804

Downlink EGPRS2-A

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-118611

Abis IP over E1/T1

Interval Type

GBFD-118611

Abis IP over E1/T1

Interval Type

GBFD-118611

Abis IP over E1/T1

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

None

None

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Enumeration Type

None

None

Interval Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

GBFD-115001

Enhanced Multi Level Precedence


and Preemption(EMLPP)

Enumeration Type

GBFD-110202
GBFD-110521

Emergency Call Service (TS12)


Guaranteed Emergency Call

Enumeration Type

GBFD-110802

Pre-processing of Measurement
Report

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-111101
GBFD-114101

System Information Sending


GPRS

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-110802

Pre-processing of Measurement
Report

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-117301

Flex Abis

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111804
GBFD-118602
GBFD-118622

A Interface Protocol Process


A over IP
A IP over E1/T1

Interval Type

GBFD-111804
GBFD-118602
GBFD-118622

A Interface Protocol Process


A over IP
A IP over E1/T1

Interval Type

None

None

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

MRFD-210305

Security Management

String Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-510002

Gb Over FR

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111610

Dynamic Cell Power Off

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Interval Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-119502

PS Handover

Enumeration Type

None

None

Enumeration Type

None

None

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111101
GBFD-119102

System Information Sending


Packet System Information

Interval Type

GBFD-119102

Packet System Information

Enumeration Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-113201

Concentric Cell

Interval Type

None

None

Enumeration Type

GBFD-111003

Radio Common Channel


Management

Interval Type

GBFD-510104

Multi-site Cell

Interval Type

None

None

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-111608

PSU Smart Control

Enumeration Type

None

None

Enumeration Type

GBFD-110402

Basic Cell Re-selection

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-119001

Gb Interface Function

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

GBFD-118401

Abis Transmission Optimization

Interval Type

None

None

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210305

Security Management

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Password Type

GBFD-111202

O&M of BTS

Password Type

MRFD-210305

Security Management

Password Type

MRFD-210305

Security Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210304

Faulty Management

Bit Field Type

MRFD-210304

Faulty Management

Bit Field Type

GBFD-117602

Active Power Control

Enumeration Type

GBFD-117601

HUAWEI III Power Control Algorithm

Enumeration Type

GBFD-110703

Enhanced Power Control Algorithm

Enumeration Type

GBFD-111003

Radio Common Channel


Management

Interval Type

GBFD-111003

Radio Common Channel


Management

Enumeration Type

GBFD-510104

Multi-site Cell

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111605

Active Backup Power Control

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-111202
MRFD-210601

O&M of BTS
Connection with TMA (Tower
Mounted Amplifier)

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-119902

QoS ARP&THP

Enumeration Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-510102

Fast Move Handover

Enumeration Type

GBFD-111202

O&M of BTS

Bit Field Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Bit Field Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Bit Field Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-510701

Compact BTS Automatic


Configuration and Planning

Interval Type

GBFD-510701

Compact BTS Automatic


Configuration and Planning

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-510702

Compact BTS Automatic Capacity


Planning

Interval Type

GBFD-111003

Radio Common Channel


Management

Interval Type

GBFD-111003

Radio Common Channel


Management

Interval Type

GBFD-111003

Radio Common Channel


Management

Interval Type

GBFD-510104

Multi-site Cell

Interval Type

GBFD-111101
GBFD-114101

System Information Sending


GPRS

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111003

Radio Common Channel


Management

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-115506
GBFD-115507

AMR Coding Rate Threshold


Adaptive Adjustment
WB AMR

Enumeration Type

GBFD-115506
GBFD-115701

AMR Coding Rate Threshold


Adaptive Adjustment
TFO

Enumeration Type

GBFD-110801

Processing of Measurement Report

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-112501

TCH Re-assignment

Enumeration Type

GBFD-112501

TCH Re-assignment

Enumeration Type

GBFD-113201
GBFD-115501

Concentric Cell
AMR FR

Interval Type

GBFD-113201
GBFD-115502

Concentric Cell
AMR HR

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

GBFD-117702

BTS Local Switch

Interval Type

GBFD-113725

BSC Node Redundancy

Compound Type

GBFD-113725

BSC Node Redundancy

Interval Type

GBFD-113725

BSC Node Redundancy

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118605

IP QOS

String Type

None

None

String Type

GBFD-118603

Gb over IP

Interval Type

GBFD-113602

Simplified Cell Broadcast

Interval Type

GBFD-113721

Robust Air Interface Signalling

Enumeration Type

GBFD-113721

Robust Air Interface Signalling

Interval Type

GBFD-113721

Robust Air Interface Signalling

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-116201

Network-Controlled Cell Reselection


Interval Type
(NC2)

GBFD-113101

PDCH Dynamic Adjustment

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210305

Security Management

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-111612

Multi-Carrier Intelligent Voltage


Regulation

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-119001

Gb Interface Function

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111203
MRFD-210403

O&M of BSC
License Management

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

MRFD-210304

Faulty Management

Bit Field Type

MRFD-211402

MBSC Load Balancing

Interval Type

GBFD-116001

Resource Reservation

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111004
GBFD-111101

Radio Dedicated Channel


Management
System Information Sending

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-119301

Voice Fault Diagnosis

Enumeration Type

GBFD-510401

BTS GPS Synchronization

Enumeration Type

GBFD-116301

Network Assisted Cell Change


(NACC)

Enumeration Type

None

None

Bit Field Type

GBFD-111004

Radio Dedicated Channel


Management

Enumeration Type

GBFD-116902

Ater Compression Transmission

Enumeration Type

MRFD-210301

Configuration Management

Interval Type

MRFD-211402

MBSC Load Balancing

Interval Type

MRFD-211402

MBSC Load Balancing

Interval Type

MRFD-211402

MBSC Load Balancing

String Type

MRFD-210305

Security Management

String Type

GBFD-118603

Gb over IP

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Enumeration Type

GBFD-119107

Networking Control Mode

Enumeration Type

GBFD-119107
GBFD-114302

Networking Control Mode


GSM/TD-SCDMA Interoperability

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-116801

Voice Quality Index (Uplink VQI)

Enumeration Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Interval Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Enumeration Type

None

None

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

None

None

Enumeration Type

None

None

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118601

Abis over IP

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

MRFD-210401

BSC/RNC Software Management

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-118611

Abis IP over E1/T1

Interval Type

GBFD-110202

Emergency Call Service (TS12)

Interval Type

None

None

Enumeration Type

None

None

Interval Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Interval Type

GBFD-111701

Board Switchover

Enumeration Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-118602

A over IP

Enumeration Type

None

None

IP Address Type

None

None

IP Address Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-115506

AMR Coding Rate Threshold


Adaptive Adjustment

Enumeration Type

GBFD-510805
GBFD-119901
GBFD-119902
GBFD-119905
GBFD-119906
GBFD-111003
GBFD-510805
GBFD-119901
GBFD-119902
GBFD-119905
GBFD-119906
GBFD-111003

Latency Reduction
Streaming QoS(GBR)
QoS ARP&THP
PoC QoS
Conversational QoS
Radio Common Channel
Management
Latency Reduction
Streaming QoS(GBR)
QoS ARP&THP
PoC QoS
Conversational QoS
Radio Common Channel
Management

Interval Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-115501
GBFD-510501
GBFD-110601

AMR FR
HUAWEI II Handover
HUAWEI I Handover

Interval Type

GBFD-111101

System Information Sending

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

None

None

Enumeration Type

None

None

Interval Type

GBFD-112301
MRFD-210304

Remote EAC Maintenance


Faulty Management

Bit Field Type

GBFD-111202

O&M of BTS

Bit Field Type

GBFD-510301

Public Voice Group Call Service

Enumeration Type

GBFD-118103

Network Support SAIC

Enumeration Type

GBFD-118103

Network Support SAIC

Interval Type

GBFD-118103

Network Support SAIC

Interval Type

MRFD-210304

Faulty Management

Bit Field Type

GBFD-111610

Dynamic Cell Power Off

Interval Type

GBFD-111610

Dynamic Cell Power Off

Enumeration Type

GBFD-111610

Dynamic Cell Power Off

Interval Type

GBFD-111610

Dynamic Cell Power Off

Interval Type

GBFD-111610

Dynamic Cell Power Off

String Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

MRFD-210304

Faulty Management

Bit Field Type

GBFD-112301
MRFD-210304

Remote EAC Maintenance


Faulty Management

Bit Field Type

GBFD-112301
MRFD-210304

Remote EAC Maintenance


Faulty Management

Bit Field Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Bit Field Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

String Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Enumeration Type

GBFD-118603

Gb over IP

Interval Type

GBFD-510102

Fast Move Handover

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111202

O&M of BTS

String Type

GBFD-113602

Simplified Cell Broadcast

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203

O&M of BSC

Any Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-118602
GBFD-118622

A over IP
A IP over E1/T1

Interval Type

MRFD-210304

Faulty Management

Compound Type

MRFD-210304

Faulty Management

Compound Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111701

Board Switchover

Enumeration Type

GBFD-111202

O&M of BTS

Compound Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-110502

Assignment and Immediate


Assignment

Enumeration Type

GBFD-110502

Assignment and Immediate


Assignment

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-113001

SDCCH Dynamic Adjustment

Enumeration Type

GBFD-111701

Board Switchover

Enumeration Type

GBFD-113503

A5/3 Ciphering Algorithm

Enumeration Type

GBFD-111605

Active Backup Power Control

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-111701

Board Switchover

Enumeration Type

GBFD-111202
GBFD-111601

O&M of BTS
BTS Power Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-117501

Enhanced Measurement
Report(EMR)

Enumeration Type

GBFD-111202

O&M of BTS

String Type

GBFD-111101

System Information Sending

Enumeration Type

GBFD-116401

End-to-End MS Signaling Tracing

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-110203

Point To Point Short Message Service


Enumeration Type
(TS21, TS22)

GBFD-510307

Group Call EMLPP

Enumeration Type

GBFD-510307

Group Call EMLPP

Enumeration Type

GBFD-111612

Multi-Carrier Intelligent Voltage


Regulation

Enumeration Type

GBFD-111101

System Information Sending

Enumeration Type

GBFD-111101

System Information Sending

Enumeration Type

GBFD-111101

System Information Sending

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

MRFD-210602

Remote Electrical Tilt

String Type

GBFD-111203

O&M of BSC

IP Address Type

GBFD-118602
GBFD-113726

A over IP
TC Pool

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-510601

PICO Automatic Configuration and


Planning

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-119701

SGSN Pool

Interval Type

MRFD-210301

Configuration Management

String Type

GBFD-119701

SGSN Pool

Interval Type

GBFD-119701

SGSN Pool

Interval Type

GBFD-119701

SGSN Pool

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-119701

SGSN Pool

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-118701

RAN Sharing

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-111605

Active Backup Power Control

Interval Type

GBFD-111101

System Information Sending

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-118602

A over IP

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-111804
GBFD-115301

A Interface Protocol Process


Local Multiple Signaling Points

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-119303

Load Sharing

Interval Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

GBFD-111203

O&M of BSC

String Type

None

None

IP Address Type

None

None

IP Address Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118606

Clock over IP

IP Address Type

GBFD-510104

Multi-site Cell

Interval Type

GBFD-111207

BTS Test Function

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-113725

BSC Node Redundancy

Interval Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Enumeration Type

None

None

Interval Type

None

None

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Enumeration Type

WRFD-040100

Flow Control

Interval Type

GBFD-118602

A over IP

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

MRFD-211402

MBSC Load Balancing

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111802
GBFD-111804

14-Digit Signaling Point Code


A Interface Protocol Process

Interval Type

GBFD-111802
GBFD-111804

14-Digit Signaling Point Code


A Interface Protocol Process

Enumeration Type

GBFD-111802
GBFD-111804

14-Digit Signaling Point Code


A Interface Protocol Process

String Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111003
GBFD-110301
GBFD-110302

Radio Common Channel


Management
Location Updating
IMSI Detach

Bit Field Type

MRFD-210304

Faulty Management

Bit Field Type

MRFD-210304

Faulty Management

Bit Field Type

GBFD-119301

Voice Fault Diagnosis

Interval Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-510309

Group Call Reliability Enhancing

Enumeration Type

GBFD-510309

Group Call Reliability Enhancing

Enumeration Type

GBFD-510309

Group Call Reliability Enhancing

Enumeration Type

None

None

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-111101
GBFD-114802

System Information Sending


Discontinuous Reception (DRX)

Enumeration Type

GBFD-113601

Short Message Service Cell


Broadcast (TS23)

Enumeration Type

MRFD-211402

MBSC Load Balancing

Enumeration Type

MRFD-211402

MBSC Load Balancing

Enumeration Type

GBFD-119502

PS Handover

Enumeration Type

GBFD-119502

PS Handover

Enumeration Type

GBFD-116301

Network Assisted Cell Change


(NACC)

Enumeration Type

GBFD-510301

Public Voice Group Call Service

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-118701

RAN Sharing

Enumeration Type

GBFD-510805

Latency Reduction

Enumeration Type

GBFD-118701

RAN Sharing

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-210301

Configuration Management

String Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

String Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111203

O&M of BSC

String Type

MRFD-210502

BSC/RNC Clock

Interval Type

MRFD-210502

BSC/RNC Clock

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-118609

IP Fault Detection Based on BFD

IP Address Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

String Type

None

None

Interval Type

MRFD-210301

Configuration Management

String Type

None

None

Interval Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

None

None

Bit Field Type

GBFD-118602

A over IP

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

MRFD-211402

MBSC Load Balancing

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

MRFD-210301

Configuration Management

String Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-118603

Gb over IP

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-111202
GBFD-117804

O&M of BTS
Intelligent Shutdown of TRX Due to
PSU Failure

Enumeration Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-211402

MBSC Load Balancing

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-210304

Faulty Management

Compound Type

MRFD-210304

Faulty Management

Compound Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Compound Type

GBFD-113602

Simplified Cell Broadcast

Compound Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Compound Type

MRFD-210304

Faulty Management

Interval Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-510309

Group Call Reliability Enhancing

Interval Type

GBFD-111602

TRX Power Amplifier Intelligent


Shutdown

Compound Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111801

Ater Interface 4:1 Multiplexing

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Compound Type

GBFD-510901

2G/3G Neighboring Cell Automatic


Optimization

Interval Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111202

O&M of BTS

Compound Type

GBFD-115821

EICC

Enumeration Type

GBFD-113521

A5/1 Encryption Flow Optimization

Enumeration Type

GBFD-510309

Group Call Reliability Enhancing

Interval Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-112401

Cell Frequency Scan

Compound Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Compound Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-113726

TC Pool

Interval Type

GBFD-113726

TC Pool

Interval Type

GBFD-111202

O&M of BTS

String Type

GBFD-118604
GBFD-118610

Abis MUX
UDP MUX for A Transmission

Interval Type

GBFD-118604

Abis MUX

Interval Type

GBFD-111203

O&M of BSC

Interval Type

None

None

Interval Type

GBFD-117301

Flex Abis

Enumeration Type

GBFD-117301

Flex Abis

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111803

A Interface Circuit Management

Enumeration Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

MRFD-210502

BSC/RNC Clock

Enumeration Type

GBFD-113602

Simplified Cell Broadcast

Enumeration Type

GBFD-113101
GBFD-119402
GBFD-119303
GBFD-119501

PDCH Dynamic Adjustment


MS High multislot classes
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Enumeration Type

GBFD-114151

DTM

Enumeration Type

GBFD-113101
GBFD-119401
GBFD-119303
GBFD-119501

PDCH Dynamic Adjustment


EDA(Extended Dynamic Allocation)
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Enumeration Type

GBFD-114151

DTM

Enumeration Type

GBFD-117702

BTS Local Switch

Enumeration Type

GBFD-115701

TFO

Enumeration Type

MRFD-211404

MBSC Handover based on Load


Enhancement

Enumeration Type

GBFD-119110

Access

Enumeration Type

GBFD-118603

Gb over IP

IP Address Type

GBFD-118603

Gb over IP

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-118609

IP Fault Detection Based on BFD

Enumeration Type

MRFD-210403

License Management

Enumeration Type

None

None

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-115501
GBFD-115502
GBFD-115701

AMR FR
AMR HR
TFO

Enumeration Type

GBFD-118602

A over IP

Enumeration Type

GBFD-118602

A over IP

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Enumeration Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Enumeration Type

GBFD-117002
GBFD-118201

IBCA (Interference Based Channel


Allocation)
Soft-Synchronized Network

Enumeration Type

GBFD-118606

Clock over IP

Enumeration Type

GBFD-118606

Clock over IP

Interval Type

GBFD-118606

Clock over IP

Interval Type

GBFD-118606

Clock over IP

Interval Type

MRFD-210301

Configuration Management

String Type

MRFD-210301

Configuration Management

String Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-210301

Configuration Management

String Type

GBFD-510301

Public Voice Group Call Service

Enumeration Type

MRFD-210301

Configuration Management

String Type

MRFD-210301

Configuration Management

String Type

GBFD-118601

Abis over IP

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-117801

Ring Topology

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-111002

Radio Link Management

Interval Type

GBFD-117802

Fast Ring Network Switch

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-510302

Public Voice Broadcast Service

Interval Type

GBFD-114101

GPRS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-110301

Location Updating

Interval Type

GBFD-510002

Gb Over FR

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-510306

Talker Identification

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-119115

Power Control

Interval Type

GBFD-119115

Power Control

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-113728

OML Backup

Interval Type

GBFD-117801

Ring Topology

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203
GBFD-113726

O&M of BSC
TC Pool

Enumeration Type

GBFD-113402

Dynamic Adjustment Between FR


and HR

Enumeration Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-111004

Radio Dedicated Channel


Management

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-113521

A5/1 Encryption Flow Optimization

Interval Type

GBFD-113521

A5/1 Encryption Flow Optimization

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

None

None

Interval Type

GBFD-113726

TC Pool

Interval Type

None

None

Interval Type

None

None

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Enumeration Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Enumeration Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Interval Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Enumeration Type

GBFD-114302

GSM/TD-SCDMA Interoperability

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111203

O&M of BSC

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210301

Configuration Management

String Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

Interval Type

MRFD-210301

Configuration Management

String Type

GBFD-111202
GBFD-111601

O&M of BTS
BTS Power Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111101

System Information Sending

Enumeration Type

GBFD-119001

Gb Interface Function

Interval Type

GBFD-113602

Simplified Cell Broadcast

Any Type

GBFD-115701

TFO

Enumeration Type

GBFD-111207

BTS Test Function

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

None

None

Interval Type

None

None

IP Address Type

None

None

IP Address Type

None

None

Interval Type

None

None

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-119902

QoS ARP&THP

Interval Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-119701

SGSN Pool

Interval Type

GBFD-118001

BCCH Dense Frequency Multiplexing Interval Type

GBFD-118001

BCCH Dense Frequency Multiplexing Interval Type

GBFD-118001

BCCH Dense Frequency Multiplexing Interval Type

GBFD-118001

BCCH Dense Frequency Multiplexing Interval Type

GBFD-118001

BCCH Dense Frequency Multiplexing Interval Type

GBFD-118001

BCCH Dense Frequency Multiplexing Interval Type

GBFD-118001

BCCH Dense Frequency Multiplexing Enumeration Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

GBFD-117401

MSC Pool

Interval Type

GBFD-112401

Cell Frequency Scan

Interval Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-118604

Abis MUX

Interval Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

None

None

Interval Type

GBFD-111606

Power Optimization Based on


Channel Type

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-117401

MSC Pool

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Interval Type

GBFD-114101

GPRS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-111203

O&M of BSC

Compound Type

GBFD-118605

IP QOS

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-111207

BTS Test Function

Enumeration Type

GBFD-110501

Call Control

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111203

O&M of BSC

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

GBFD-111804

A Interface Protocol Process

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-113903

Satellite Transmission over Ater


Interface

Enumeration Type

GBFD-110402

Basic Cell Re-selection

Interval Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Interval Type

MRFD-211501

IP-Based 2G/3G Co-Transmission on


Base Station Side

Interval Type

MRFD-211501

IP-Based 2G/3G Co-Transmission on


Base Station Side

Interval Type

MRFD-211501

IP-Based 2G/3G Co-Transmission on


Base Station Side

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-119501

Adaptive Adjustment of Uplink and


Downlink Channels

Interval Type

GBFD-119501

Adaptive Adjustment of Uplink and


Downlink Channels

Interval Type

GBFD-118602

A over IP

Enumeration Type

GBFD-113901

Satellite Transmission over Abis


Interface

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118605

IP QOS

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-210103

Link aggregation

Interval Type

MRFD-210103

Link aggregation

Interval Type

MRFD-210103

Link aggregation

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

None

None

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-118609

IP Fault Detection Based on BFD

Interval Type

None

None

Interval Type

GBFD-113801

TRX Cooperation

Enumeration Type

GBFD-111207

BTS Test Function

Interval Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-510104

Multi-site Cell

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-113703

Antenna Frequency Hopping

Interval Type

GBFD-111207

BTS Test Function

Interval Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

String Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Interval Type

MRFD-210301

Configuration Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-510104

Multi-site Cell

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111803

A Interface Circuit Management

Interval Type

GBFD-111801

Ater Interface 4:1 Multiplexing

Interval Type

GBFD-510002

Gb Over FR

Bit Field Type

None

None

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-118611

Abis IP over E1/T1

Bit Field Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Bit Field Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Bit Field Type

GBFD-113701

Frequency Hopping (RF hopping,


baseband hopping)

Interval Type

GBFD-114101
GBFD-117301

GPRS
Flex Abis

Interval Type

GBFD-118201

Soft-Synchronized Network

Enumeration Type

None

None

Interval Type

GBFD-111207

BTS Test Function

Interval Type

GBFD-114701

Semi-Permanent Connection

Interval Type

GBFD-111203

O&M of BSC

String Type

MRFD-210301

Configuration Management

Bit Field Type

MRFD-211501

IP-Based 2G/3G Co-Transmission on


Base Station Side

Bit Field Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Interval Type

GBFD-119501

Adaptive Adjustment of Uplink and


Downlink Channels

Interval Type

GBFD-119501

Adaptive Adjustment of Uplink and


Downlink Channels

Enumeration Type

GBFD-114701

Semi-Permanent Connection

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111207

BTS Test Function

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111207

BTS Test Function

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111603

TRX Power Amplifier Intelligent


Shutdown on Timeslot Level

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

None

None

Interval Type

None

None

Interval Type

GBFD-111610

Dynamic Cell Power Off

Interval Type

GBFD-111610

Dynamic Cell Power Off

Compound Type

GBFD-111610

Dynamic Cell Power Off

Compound Type

GBFD-111610

Dynamic Cell Power Off

Enumeration Type

GBFD-111610

Dynamic Cell Power Off

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-118201

Soft-Synchronized Network

Interval Type

GBFD-111003
GBFD-110301

Radio Common Channel


Management
Location Updating

Enumeration Type

GBFD-118701

RAN Sharing

Interval Type

GBFD-118701

RAN Sharing

Interval Type

GBFD-118701

RAN Sharing

Interval Type

GBFD-118701

RAN Sharing

Interval Type

GBFD-118701

RAN Sharing

Interval Type

GBFD-118701

RAN Sharing

Interval Type

GBFD-118701

RAN Sharing

Interval Type

GBFD-118701

RAN Sharing

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-118605

IP QOS

Interval Type

GBFD-119110

Access

Enumeration Type

None

None

Interval Type

GBFD-510701

Compact BTS Automatic


Configuration and Planning

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-110101

Frequency Band

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118602

A over IP

Enumeration Type

GBFD-111005

Enhanced Channel Assignment


Algorithm

Enumeration Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118602

A over IP

Enumeration Type

GBFD-118604
GBFD-118610

Abis MUX
UDP MUX for A Transmission

Enumeration Type

GBFD-118604
GBFD-118610

Abis MUX
UDP MUX for A Transmission

Enumeration Type

GBFD-118603

Gb over IP

Interval Type

GBFD-118603

Gb over IP

Interval Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Interval Type

None

None

Interval Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-510501

HUAWEI II Handover

Interval Type

GBFD-119501

Adaptive Adjustment of Uplink and


Downlink Channels

Interval Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-119105

RLC Mode

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-119105

RLC Mode

Interval Type

GBFD-119105

RLC Mode

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115507

WB AMR

Interval Type

GBFD-115507

WB AMR

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-511103

GSM and UMTS Load Balancing


Based on Iur-g

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-115501
GBFD-510501
GBFD-110601

AMR FR
HUAWEI II Handover
HUAWEI I Handover

Interval Type

GBFD-115502
GBFD-510501
GBFD-110601

AMR HR
HUAWEI II Handover
HUAWEI I Handover

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-117601

HUAWEI III Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-110703

Enhanced Power Control Algorithm

Interval Type

GBFD-115501
GBFD-115507

AMR FR
WB AMR

Interval Type

GBFD-115501
GBFD-115507

AMR FR
WB AMR

Interval Type

GBFD-115501
GBFD-115507

AMR FR
WB AMR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115502

AMR HR

Interval Type

GBFD-115507

WB AMR

Interval Type

GBFD-115507

WB AMR

Interval Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-119105

RLC Mode

Interval Type

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

MRFD-210301

Configuration Management

Enumeration Type

None

None

Enumeration Type

GBFD-510002

Gb Over FR

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304
MRFD-210601

Faulty Management
Connection with TMA (Tower
Mounted Amplifier)

Interval Type

MRFD-210304

Faulty Management

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-113602

Simplified Cell Broadcast

Interval Type

GBFD-114101
GBFD-119106
GBFD-114101
GBFD-119106

GPRS
Coding Scheme
GPRS
Coding Scheme

Enumeration Type

GBFD-114201
GBFD-119106
GBFD-114201
GBFD-119106

EGPRS
Coding Scheme
EGPRS
Coding Scheme

Enumeration Type

GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501
GBFD-114101
GBFD-113101
GBFD-119303
GBFD-119501

GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels
GPRS
PDCH Dynamic Adjustment
Load Sharing
Adaptive Adjustment of Uplink and
Downlink Channels

Interval Type

GBFD-510803

Uplink EGPRS2-A

Enumeration Type

GBFD-510803

Uplink EGPRS2-A

Enumeration Type

GBFD-119203

Extended Uplink TBF

Interval Type

GBFD-114101
GBFD-119106
GBFD-114101
GBFD-119106

GPRS
Coding Scheme
GPRS
Coding Scheme

Enumeration Type

GBFD-114201
GBFD-119106
GBFD-114201
GBFD-119106

EGPRS
Coding Scheme
EGPRS
Coding Scheme

Enumeration Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-510309

Group Call Reliability Enhancing

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-110703
GBFD-117601

Enhanced Power Control Algorithm


HUAWEI III Power Control Algorithm

Enumeration Type

GBFD-118605

IP QOS

Interval Type

None

None

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110601
GBFD-510501

HUAWEI I Handover
HUAWEI II Handover

Interval Type

GBFD-110203

Point To Point Short Message Service


Enumeration Type
(TS21, TS22)

GBFD-119203

Extended Uplink TBF

Interval Type

GBFD-119106

Coding Scheme

Interval Type

GBFD-118901
GBFD-119106
GBFD-118901
GBFD-119106

CS-3/CS-4
Coding Scheme
CS-3/CS-4
Coding Scheme

Interval Type

GBFD-118901
GBFD-119106
GBFD-118901
GBFD-119106

CS-3/CS-4
Coding Scheme
CS-3/CS-4
Coding Scheme

Interval Type

GBFD-119106

Coding Scheme

Interval Type

GBFD-118901
GBFD-119106
GBFD-118901
GBFD-119106

CS-3/CS-4
Coding Scheme
CS-3/CS-4
Coding Scheme

Interval Type

GBFD-118901
GBFD-119106
GBFD-118901
GBFD-119106

CS-3/CS-4
Coding Scheme
CS-3/CS-4
Coding Scheme

Interval Type

GBFD-116201

Network-Controlled Cell Reselection


Enumeration Type
(NC2)

GBFD-111203

O&M of BSC

Enumeration Type

GBFD-114101

GPRS

Enumeration Type

GBFD-111203
MRFD-210403

O&M of BSC
License Management

String Type

GBFD-111202

O&M of BTS

String Type

GBFD-111202

O&M of BTS

Compound Type

GBFD-111202

O&M of BTS

Compound Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Enumeration Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-113201

Concentric Cell

Interval Type

GBFD-114301
GBFD-114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA Interoperability

Enumeration Type

GBFD-111202

O&M of BTS

String Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Interval Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Enumeration Type

GBFD-510301
GBFD-510302

Public Voice Group Call Service


Public Voice Broadcast Service

Interval Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111705

GSM Flow Control

Enumeration Type

GBFD-111705

GSM Flow Control

Interval Type

GBFD-118605

IP QOS

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

None

None

Enumeration Type

GBFD-118611
GBFD-118622

Abis IP over E1/T1


A IP over E1/T1

Interval Type

GBFD-118601

Abis over IP

Interval Type

GBFD-118630

Ethernet OAM

Interval Type

GBFD-118630
MRFD-210301

Ethernet OAM
Configuration Management

Interval Type

None

None

Interval Type

None

None

Interval Type

GBFD-118601

Abis over IP

Interval Type

None

None

Interval Type

GBFD-118601

Abis over IP

Enumeration Type

MRFD-210301

Configuration Management

Bit Field Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

String Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

MRFD-210304

Faulty Management

Interval Type

MRFD-210304

Faulty Management

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-110501

Call Control

Interval Type

GBFD-115501

AMR FR

Interval Type

GBFD-115502

AMR HR

Interval Type

None

None

Interval Type

GBFD-110202
GBFD-110521

Emergency Call Service (TS12)


Guaranteed Emergency Call

Interval Type

GBFD-117002

IBCA (Interference Based Channel


Allocation)

Interval Type

None

None

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210304

Faulty Management

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-115402
GBFD-118201

BSS-Based LCS (Cell ID + TA)


Soft-Synchronized Network

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-118609

IP Fault Detection Based on BFD

Enumeration Type

GBFD-118601

Abis over IP

Enumeration Type

GBFD-111203
MRFD-210305

O&M of BSC
Security Management

Enumeration Type

GBFD-118602

A over IP

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Interval Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

MRFD-210301

Configuration Management

Enumeration Type

None

None

Enumeration Type

GBFD-111202

O&M of BTS

Enumeration Type

GBFD-111203

O&M of BSC

Interval Type

GBFD-113728

OML Backup

Interval Type

GBFD-117801

Ring Topology

Interval Type

GBFD-111701

Board Switchover

Interval Type

GBFD-116101
MRFD-210301

Support of Daylight Saving Time


Configuration Management

Enumeration Type

GUI Value Range


0~70

0~70

10~80

TRUE(Support), FALSE(Not Support)

NO(No), YES(Yes)

10~255

10~255

IDLETSALLOC_0(Any idle timeslots under the same site),


IDLETSALLOC_1(Idle timeslots on same E1 primary link
preferred), IDLETSALLOC_2(Idle timeslots on same E1 primary
link only), IDLETSALLOC_3(Idle timeslots on same 64K primary
link only)

CLOSE(CLOSE), OPEN(OPEN)

0~100

NO(NO), YES(YES)

10~3600

GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus

1~255

0~250

8BIT(8BIT), 11BIT(11BIT)

0~65535

NO(No), YES(Yes)

0~31
OSubcell(Overlaid subcell), USubcell(Underlaid subcell),
NoPrefer(No preference)
0~31
ULPRIORITY(Uplink Priority), NEUTRAL(Neutral Priority),
DLPRIORITY(Downlink Priority)
0~9

1~10

15~7200

NO(No), YES(Yes)

Disable(Disable), Enable(Enable)

CLOSE(Close), OPEN(Open)

COMPUL0(Compulsory 0), COMPUL1(Compulsory 1),


FLEX(Flexible)

4_75KBIT/S~0 5_15KBIT/S~1 5_90KBIT/S~2 6_70KBIT/S~3


7_40KBIT/S~4 7_95KBIT/S~5 10_2KBIT/S~6 12_2KBIT/S

4_75KBIT/S~0 5_15KBIT/S~1 5_90KBIT/S~2 6_70KBIT/S~3


7_40KBIT/S~4 7_95KBIT/S

6_60KBIT/S, 8_85KBIT/S, 12_65KBIT/S

NO(No), YES(Yes)

1~255

60~300

610~3000

600~2990

60~300

NO(No), YES(Yes)

0~254

0~50

0~768

PORT0_CDEF, PORT1_CDEF

1~16777215

BYMANUAL(By Manual), BYAUTO(By Auto)

0(Not support dynamic adjustment), 1(According to downlink


quality measurements reported by MS), 2(According to uplink
quality measurements reported by BTS)

OFF(OFF), ON(ON)

COMMON_DLD(Common Download), QUICK_DLD1(Quick


Download No Traffic), QUICK_DLD2(Quick Download Reserve
BCCH)

LOCK(Lock), UNLOCK(Unlock), SHUTDOWN(Shutdown)

Lock(Lock), Unlock(Unlock), Shutdown(Shutdown)

Lock(Lock), Unlock(Unlock), Shutdown(Shutdown)

hour, min

0~100

OFF(OFF), ON(ON)

hour, min

RATIORULE(Ratio Rule)

None

None

0~600

0~60

-60~-35,0

0~1000

0~15

CLOSE(Close), OPEN(Open)

10~100

1~10

4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times,


28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times,
52_Times, 56_Times, 60_Times, 64_Times

0~63

0~65534
BSC(BSC)

4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times,


28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times,
52_Times, 56_Times, 60_Times, 64_Times

0~63

65334~65383

1~65535

1~65535

1~65535

1~65535

None

65033~65533

1~60

ALL(All), ONEBYONE(One by One)

ALL(all), ONEBYONE(one by one)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

ABIS(Abis), A(A)

0~100

0~100

0~100

0~100

0~100

0~100
NO(Not Supported), R3(Only R3 Supported), R2(Only R2
Supported), R2ANDR3(R2 And R3 Supported)

-12~12

-23~-4

3~12

-23~-4

-23~-4
FIXEDLEVEL(Fixed level mode), ADAPTIVE(Adaptive mode),
FIXEDGAIN(Fixed gain mode)
CLOSE(Close), OPEN(Open)

5~15

1~255

0~4000000

NOTALLOW(Not Allow), ALLOW(Allow)

OFF(OFF), ON(ON)

0~100

NOTALLOW(Not Allow), ALLOW(Allow)

0~16

0~100

ALLCIC(Set all Timeslots CIC), ALLNULL(Set all Timeslots Null)

ALLCIC(Set all Timeslots CIC), ALLNULL(Set all Timeslots Null)

0~2000

0~2000

0~2000

0~2000

0~2000

0~2000

0~65535

NO(NO), YES(YES)

0~65534

0~65535

0~15

45~155

125~175

0~65535

0~100

0~100

0~250

0~250

NO(NO), YES(YES)

flt(Fault), evt(Event), all(All)

0(0.0), 1(0.1), 2(0.2), 3(0.3), 4(0.4), 5(0.5), 6(0.6), 7(0.7), 8(0.8),


9(0.9), 10(1.0)

0~9
-1000~10000
0~6553
-3281~32810

Critical, Major, Minor, Warning

Critical(Critical), Major(Major), Minor(Minor), Warning(Warning)

DISABLED(Disabled), ENABLED(Enabled)

DISABLED(Disabled), ENABLED(Enabled)

DISABLED(Disabled), ENABLED(Enabled)

DISABLED(Disabled), ENABLED(Enabled)

DISABLED(Disabled), ENABLED(Enabled)

DISABLED(Disabled), ENABLED(Enabled)

1~16

OFF(Not Allowed), ON(Allowed)

NO(No), YES(Yes)

1~20

0~3

0~7

0~7

1~20

0~7

0~63

0~63

0~63

NO(No), YES(Yes)

0~255

0~255

0~255

0~255

0~7

0~100

0~255

0~255

NO(No), YES(Yes)

0~7

0~100

0~32

0~30

0~30

0~30

0~32

NO(No), YES(Yes)

1~15

0~4

0~15

OFF(Off), ON(On)

0~99

NO(No), YES(Yes)

1~20

0~3

0~7

0~7

1~20

0~7

0~63

0~63

0~63

0~65535

0~65535

3~30

CLOSE(Close), OPEN(Open)

10~30

None

0~4599

0~4599

None

MODE0(Mode 0), MODE1(Mode 1), MODE2(Mode 2)

-32~0

-64~0

CLOSE(Close), OPEN(Open)

0~360

0~1000

SENDPOWER(Send Power), NOPOWER(No Power)

OFF(OFF), ON(ON)

NO(No), YES(Yes)

0~35

A(A), B(B)

A(A), B(B)

A(A), B(B), NULL(NULL)

0~335

M3UA(M3UA), BBAP(BBAP)

MTP2(MTP2), OTHER(OTHER), TCSTM1(TCSTM1)


1~65535

1~65535

1~65535

1~65535

1~65535

1~65535

CLOSE(Close), OPEN(Open)

1~65535

0~65535
PRIMARY(Primary Area), STANDBY(Standby Area), ALL(Primary
and Standby Area)
PRIMARY(Primary), STANDBY(Standby)

0~80

5~126

5~100

3~10

3~10
0~27
0~27
0~11
power, env, sig, trunk, hardware, software, run, comm, service,
handle
power(Power System), env(Environment System), sig(Signaling
System), trunk(Trunk System), hardware(Hardware System),
software(Software System), run(Running System),
comm(Communication System), service(QoS), handle(Processing
Error)

OFF(Off), ON(On)

DISABLE(Disable), ENABLE(Enable)

0~61

0~62,255

0~62

0~23,255

0~23

0~255

0~254

0~63

500~60000

1~300

1~300

1~300

1~300

1~300

1~300

1~300

NO(Close), YES(Open)

0~63

0~63

NO(No), YES(Yes)

Close(Close), Open(Open)

80~100

0~254

0~100

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

NO, YES

0~1

0~254

0~2047

TDM(TDM), IP(IP)

A(Tributary A), B(Tributary B), ALL(All Tributary)


TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

NO(No), YES(Yes)

0~15

0~15

1~65535

1~60

SERVER(Server), CLIENT(Client)

SERVER(SERVER), CLIENT(CLIENT)

SERVER(SERVER), CLIENT(CLIENT)

NONE(Verify None), PEER(Verify Peer Certificate)

None

None

None

None

None

None

NO_V(No Validate), PAP_V(PAP Validate), CHAP_V(CHAP Validate)

NO_V(NO_V), PAP_V(PAP_V), CHAP_V(CHAP_V)

NO_V(NO_V), PAP_V(PAP_V), CHAP_V(CHAP_V)

ENABLE, DISABLE

NO(NO), YES(YES)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

DISABLED(Disabled), ENABLED(Enabled)

BTSAUTODLDACT(BTS Software Auto DL and ACT),


TMUAUTOACT(TMU Software Auto ACT)

OFF(Off), ON(On)

1~65535

AU4(AU4), AU3(AU3)

GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus

LOW(LOW), HIGH(HIGH)

LOW(LOW), HIGH(HIGH)

O1E3_R1E4(OCCUR:1E-3, RECOVERY:1E-4),
O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5),
O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6),
O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7),
O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8),
O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9),
O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10),
O1E10_R1E11(OCCUR:1E-10, RECOVERY:1E-11),
O1E11_R1E12(OCCUR:1E-11, RECOVERY:1E-12)
O1E3_R1E4(OCCUR:1E-3, RECOVERY:1E-4),
O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5),
O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6),
O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7),
O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8),
O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9),
O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10),
O1E10_R1E11(OCCUR:1E-10, RECOVERY:1E-11),
O1E11_R1E12(OCCUR:1E-11, RECOVERY:1E-12)
O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5),
O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6),
O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7),
O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8),
O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9),
O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10),
O1E10_R1E11(OCCUR:1E-10, RECOVERY:1E-11)
O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5),
O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6),
O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7),
O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8),
O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9),
O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10),
O1E10_R1E11(OCCUR:1E-10, RECOVERY:1E-11)
OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

None

None

0~70

CLOSE(Close), LOCALTLLI(Local TLLI Opt), ALLTLLI(All TLLI Opt)

None

None

None

BYTRX(Turn off TRX), BYPWR(Reduce Backup Power)

BYCOVER(Cover Priority), BYCAP(Capability Priority),


BYSAVING(Saving Priority)

0~1

0~1

0~1

1~200

None

0~2047

Battery1Temp(Battery 1 Temperature), Battery2Temp(Battery 2


Temperature)

Battery1Temp(Battery 1 Temperature), Battery2Temp(Battery 2


Temperature)

30~1000

NO(NO), YES(YES)

0~90

NO_BAT(No Storage Battery), INSIDE_BAT(Inside Storage


Battery), OUTSIDE_BAT(Outside Storage Battery)

1024~65535

0~254

0~5000

0~7

0~7

0~7

0~1023

0~1023

NO_Hop(No hop), Hop(Hop)

0~100

0~100

0~63

0~511

5~25

433~576

NO(NO), YES(YES)

1~10

1~10

1~10

MTP3(MTP3), M3UA(M3UA), MTP3_M3UA(MTP3 and M3UA)

1~60

0~10

0~3

NO(No), YES(Yes)

NO(No), YES(Yes)

1~32

1~32

3~10

1~2

10~254

ALL(All), PART(Part)

-10000~10000

1~10

1~10

1~10

DISABLE(Disable), ENABLE(Enable)

0~65534

60~65534

DISABLE(Disable), ENABLE(Enable)

1~6

1~120

0~335

0~5,8~27

0~11

0~5000

NO(NO), YES(YES)

nonrpt(Not Report), rpt(Report)

0(0), 1(1), 2(2), 3(3), 4(4), 5(5), 6(6), NULL(NULL)

0(0), 1(1), 2(2), 3(3), 4(4), 5(5), 6(6), NULL(NULL)

NO(No), YES(Yes)

1~16

0~127

1~16

SCU, GCU, XPU, INT, TNU

SCU, GCU, XPU, DPU, INT, TNU

SCU, GCU, MPU, GCP, DPU, INT, TNU

INT, DPU, XPU, TNU, OMU, SAU

0~72

0~47

0~1000

DATM_MAIN, DATU_MAIN, DDPM_MAIN, DDPU_MAIN, DDRM_MAIN,


DEMU_MAIN, DFCU_MAIN, DGPS_MAIN, DHEU_MAIN,
DOMU_MAIN, DPMU_MAIN, DPTU_MAIN, DRFU_MAIN,
DRFUBOOT_MAIN, DRRU_MAIN, DRRUBOOT_MAIN, DRU_MAIN,
DTCU_MAIN, DTMU_MAIN, DTRU_MAIN, ETR_MAIN, FMU_MAIN,
FMUA_MAIN, GATM_MAIN, GTMU_MAIN, IASU_MAIN, IOMU_MAIN,
MFU_3001C, MMU_3001C, MRRU_MAIN, MTR_MAIN, NFCB_MAIN,
PBU_MAIN, QTRU_MAIN, TMU_MAIN, TRX_MAIN, GRRU_MAIN,
BTS3900B_MAIN, BTS3900BBOOT_MAIN, MRFU_MAIN,
GRFU_MAIN, MRRUBOOT_MAIN, MRFUBOOT_MAIN, USCU_MAIN,
BTS3900E_MAIN, BTS3900EBOOT_MAIN, BOOTROM_PCK,
UBRI_MAIN, UTRP_MAIN

0~1000

DPUa, DPUc
PEUa, FG2a, GOUa, EIUa, OIUa, POUc, FG2c, GOUc, XPUa, XPUb,
DPUa, DPUb, DPUc, DPUd, TNUa, OMUa, OMUb, SAUa
FG2a, GOUa, FG2c, GOUc
PEUa, POUc

PEUa, POUc

PEUa, POUc

MRRU, GRRU, MRFU, GRFU, BTS3900E

TMU(TMU/DTMU), DTRU(DTRU), DPTU(DPTU), QTRU(QTRU),


MRRU(MRRU), GRRU(GRRU), BTS3900B(BTS3900B),
MRFU(MRFU), GRFU(GRFU), BTS3900E(BTS3900E), DRFU(DRFU),
DRRU(DRRU), UBRI(UBRI), UTRP(UTRP)

0~255

None

2~3600

ENTIRE(Entire Backup), INCREMENTAL(Incremental Backup)

0~7

1~16777215

NO(No), YES(Yes)

MAINBSC(MAIN BSC), SUBBSC(SUB BSC)

None

hour, min

hour, min

0~15

0~15

5~60

None

None

UNCONDITIONALSTART(Unconditional Start),
ATERCONGESTS(Start When Ater Congests),
PREFIXNUMBER(Start by Prefix Number)

None

NO(No), YES(Yes)

NO(No), YES(Yes)

0~335

0~65535

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

0~65535

0~65535

0~65535

0~4294967295

0~65535

0~65535

0~65535

0~65535

0~65535

0~65535

0~65535

0~65535

0~4294967295

0~4294967295

0~4294967295

0~4294967295

0~4294967295

0~4294967295

0~4294967295

0~4294967295

0~4294967295

0~4294967295

0~65535

0~65535

0~65535

0~4294967295

0~4294967295

0~4294967295

0~65535

0~27

0~11

0~7

0~2500

0~15

1~15

1~31

0~15

NO(No), YES(Yes)

0~12

2_M_PERIOD(2 Multiframe Period),


Period), 4_M_PERIOD(4 Multiframe
Multiframe Period), 6_M_PERIOD(6
7_M_PERIOD(7 Multiframe Period),
Period), 9_M_PERIOD(9 Multiframe

3_M_PERIOD(3 Multiframe
Period), 5_M_PERIOD(5
Multiframe Period),
8_M_PERIOD(8 Multiframe
Period)

1~4

0~12
NEITHERSTART(Neither Start), BTSPRIORITY(BTS Priority),
BSCPRIORITY(BSC Priority), BTSONLY(BTS Only), BSCONLY(BSC
Only)

NONSUPPORT(Not Support), BASIC(Basic Fun),


ENHANCED(Enhanced Fun)

NO(NO), YES(YES)

PEUa, EIUa, OIUa, POUc


SCUa, GCUa, GCGa, PEUa, FG2a, GOUa, EIUa, OIUa, POUc, FG2c,
GOUc, XPUa, XPUb, DPUa, DPUb, DPUc, DPUd, TNUa
SCUa, GCUa, GCGa, PEUa, FG2a, GOUa, EIUa, OIUa, POUc, FG2c,
GOUc, XPUa, XPUb, DPUa, DPUb, DPUc, DPUd, TNUa, ALL
PEUa, POUc, EIUa, OIUa

PEUa, POUc, EIUa


PEUa, POUc, EIUa, OIUa
POUc, OIUa
POUc, OIUa
FG2a, GOUa, FG2c, GOUc, POUc

EIUa
CDU(CDU), PCDU(PCDU), DCDU(DCDU), CDUC(CDUC),
CDUP(CDUP), RCDU(RCDU), CDUR(CDUR), CDUE(CDUE),
EDU(EDU), PEDU(PEDU), REDU(REDU), DEDU(DEDU),
EDUC(EDUC), EDUP(EDUP), EDUR(EDUR), EDUE(EDUE),
DDPM_DDPU(DDPM_DDPU), DFCU(DFCU), DFCB(DFCB)

PWC(PWC), EAC_EMUA(EAC_EMUA), DTMU(DTMU),


DATM_DATU(DATM_DATU), NFCB(NFCB), EMU_DEMU(EMU_DEMU),
DPMU(DPMU), DCBM_DCOM(DCBM_DCOM), DHEU(DHEU),
ECOM(ECOM), MFU(MFU), MPW(MPW), MCD(MCD), IASU(IASU),
PTU(PTU), TMU(TMU), PSU_APSU(PSU_APSU),
PMU_APMU(PMU_APMU), 3001C_MFU(3001C_MFU), TEU(TEU),
TES(TES), PBU(PBU), DPBU(DPBU), RPBU(RPBU), PPBU(PPBU),
SCU(SCU), MDU(MDU), UPEU(UPEU), UEIU(UEIU), FMU(FMU),
FMUA(FMUA), DTCU(DTCU), GATM(GATM), DGPS(DGPS),
USCU(USCU), UBRI(UBRI), FAN(FAN), EMU(EMU), PMU(PMU),
TCU(TCU), PSU(PSU), UTRP(UTRP)

DRRU(DRRU), DRFU(DRFU), MRRU(MRRU), XRRU(XRRU),


MRFU(MRFU), GRFU(GRFU), GRRU(GRRU), XRFU(XRFU),
BTS3900E(BTS3900E)
TRX(TRX_DEFAULT), TRX_GPRS(TRX_GPRS), DRU(TRX_30),
PTRX(PTRX), ETRX(ETRX), RTRX(RTRX), DTRX(DTRX),
RETR(RETR), DETR(DETR), EETR(EETR), PETR(PETR), MTR(MTR),
TRU(TRU/DTRU), QTRU(QTRU)
CDU(CDU), CDUC(CDUC), CDUP(CDUP), CDUR(CDUR),
CDUE(CDUE), PCDU(PCDU), RCDU(RCDU), DCDU(DCDU),
EDU(EDU), EDUC(EDUC), EDUP(EDUP), EDUR(EDUR),
EDUE(EDUE), PEDU(PEDU), REDU(REDU), DEDU(DEDU),
DDPM_DDPU(DDPM_DDPU), DFCU(DFCU), DFCB(DFCB)

DATU(DATU), GATM(GATM), DRRU(DRRU), MRRU(MRRU),


MRFU(MRFU), GRFU(GRFU), GRRU(GRRU), BTS3900E(BTS3900E)

CFGBM(BM), CFGTC(TC)

CFGBM(BM), CFGTC(TC)

NO(No), YES(Yes)

None

LOGICIP(Logic IP), PORTIP(Port IP), PPP/MP(PPP/MP)

LOGICIP(Logic IP), PORTIP(Port IP), PPP/MP(PPP/MP)

None

CLOSE(CLOSE), OPEN(OPEN)

0~2047

0~2047

0~2047

0~2047

0~2047

BYNAME(By Name), BYID(By Index)

BYIDX(By BTS Index), BYNAME(By BTS Name)

0~2047,65535

None

UNCONDITIONALSTART(Unconditional Start),
ABISCONGESTS(Start When Abis Congests),
PREFIXNUMBER(Start by Prefix Number)

None

BSC_Preprocessing(BSC preprocessing), BTS_Preprocessing(BTS


preprocessing)

None

None

None

OFF(Off), ON(On)

NO(No), YES(Yes)

1~16

OFF(Off), ON(On)

None

1~250

BTS3900B_GSM(BTS3900B GSM), BTS3900E_GSM(BTS3900E


GSM)

BTS30, BTS312, BTS3001C, BTS3001CP, BTS3002C, BTS3012A,


BTS3006A, BTS3012, BTS3006C, BTS3002E, BTS3012AE,
BTS3012_II, DBS3900_GSM, BTS3900_GSM, BTS3900A_GSM,
DBS3036, BTS3036, BTS3036A, BTS3900B_GSM,
BTS3900E_GSM, BTS3900L_GSM

BTS3012(BTS3012), BTS3006C(BTS3006C),
BTS3002E(BTS3002E), BTS3012AE(BTS3012AE),
BTS3012_II(BTS3012_II), DBS3900_GSM(DBS3900 GSM),
BTS3900_GSM(BTS3900 GSM), BTS3900A_GSM(BTS3900A GSM),
DBS3036(DBS3036), BTS3036(BTS3036), BTS3036A(BTS3036A),
BTS3900L_GSM(BTS3900L GSM), BTS3900B_GSM(BTS3900B
GSM), BTS3900E_GSM(BTS3900E GSM)

0~1000000
BIULOOP(BIU Loopback Test), TRXSELFTEST(TRX Self Loopback
Test)
NO_BAT(No Storage Battery), INSIDE_BAT(Inside Storage
Battery), OUTSIDE_BAT(Outside Storage Battery)

10~255

NO(NO), YES(YES)

2~65534

2~65534

1000~3000

OFF(OFF), ON(ON)

0~200000

0~200000

0~100

0~100

0~200000

0~100

0~200000

0~100
0~100
0~200000
100~1000

FULL_DUPLEX(Full Duplex), HALF_DUPLEX(Half Duplex)

0~100

20~100

BYIDX(By Cell Index), BYNAME(By Cell Name)


C31NOTUSE(Not Use c31 standard), C31STANDARD(Use c31
standard)
0~1

None

0~8
NO(NO), YES(YES)

NO(No), YES(Yes)

0~4095

NO(No), YES(Yes)

OFF(OFF), ON(ON)

GSM900(GSM900), DCS1800(DCS1800), GSM850(GSM850),


PCS1900(PCS1900)
NULL(NULL), IPLGCPORT(IP Logic Port), RSCGRP(Resource Group)
ETHER, IPLOGICPORT, TRUNK, PPP, MP
ETHPORT, TRUNK

NO(NO), YES(YES)

0~3
None

0~63

0~65535

5~180

NO(No), YES(Yes)

4500~32767

1~5

0~31

0~31

0~65535

DISABLE(Disabled), ENABLE(Enabled)

0~255

20~100

0~63
10, 100, 1000

0~100

0~7

0~7

0~1023

AUTO(Auto), MANU(Manu)

0~1023

AUTO(Auto), MANU(Manu)

0~50

0~7

0~7

Permit(Permit Cell Access), NoPermit(Prohibit Cell Access)

OUTDOOR_CELL(Outdoor Cell), INDOOR_CELL(Indoor Cell)

240~289

433~576

240~289

432~575

0~2047

0~2047

0~2047,65535

0~2047

0~2047

0~2047

None

BYNAME(By name), BYID(By index)

BYNAME(By Name), BYID(By Index)

BYNAME(By Name), BYID(By Index)

Inner(Inner), Extra(Extra)

1, 2, 3, 4

None

NO(No), YES(Yes)

0~255

None

None

None

None

OP1(Operator 1), OP2(Operator 2), OP3(Operator 3),


OP4(Operator 4), NONE(Not Shared)

0~63

0~63

1~20

NO(NO), YES(YES)

350~553

2G(Preference for 2G Cell), 3G(Preference for 3G Cell)

0~100

COMMON(COMMON), MULTIPATH(MULTIPATH), INDOOR(INDOOR),


HIGHWAY(HIGHWAY)

NO(No), YES(Yes)

400~790

-190~50

0~1000

-500~0

NO(NO), YES(YES)

0~63

0~63

20~90

None

NULL(NULL), IPLGCPORT(IP Logic Port), RSCGRP(Resource Group)

NO(NO), YES(YES)

AUTO(AUTOPLAN), NORMAL(NORMAL)

ENABLE(Enable), DISABLE(Disable)

NO(NO), YES(YES)

NO(NO), YES(YES)

None
G_15, G_16, G_17, G_18, G_19, G_20, G_21, G_22, G_23, G_24,
G_25, G_26, G_27, G_28, G_29, G_30, G_31
G_0~0 G_1~1 G_2~2 G_3~3 G_4~4 G_5~5 G_6~6 G_7~7
G_8~8 G_9~9 G_10~10 G_11~11 G_12~12 G_13~13 G_14~14
G_15~15 G_16~16 G_17~17 G_18~18 G_19~19 G_20~20
G_21~21 G_22~22 G_23~23 G_24~24 G_25~25 G_26~26
G_27~27 G_28~28 G_29~29 G_30~30 G_31

20~90

20~90

OFF(OFF), ON(ON)

0~2

None

30~100

30~100

30~100

QUICK_HO_NCELL_TYPE_A(QUICK_HO_NCELL_TYPE_A),
QUICK_HO_NCELL_TYPE_B(QUICK_HO_NCELL_TYPE_B)

CHAINTORING(ChainToRing), COMBINECHAINS(CombineChains)

CAPABILITY(Capability preferred), QUALITY(Quality preferred),


PSRELATIVELY(PS relatively preferred), PSABSOLUTELY(PS
absolutely preferred)

0~100

OFF(Off), ON(On)

0~100

0~65535

NO(No), YES(Yes)

NO(No), YES(Yes)

1~64

1~5

NO(No), YES(Yes)

MODE1(Mode 1), MODE2(Mode 2), MODE3(Mode 3)

MODE1(Mode 1), MODE2(Mode 2), MODE3(Mode 3)

0~511
0~511

5~20

5~20

NO(NO), YES(YES)

NO(NO), YES(YES)

ALDER32(ALDER32), CRC32(CRC32)

SBFD, ARP, MBFD


0~12

1~7

0~169

0~7

TRXRFSELFLOOP(TRX RF Self Loopback Test), BIULOOP(BIU


Loopback Test), BTSSPEECHLOOP(BTS Speech Loopback Test),
TRXSPEECHLOOP(TRX Speech Loopback Test)

FULLTCH(FULLTCH), HALFTCH(HALFTCH)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NOSENDING(Force NO Sending), SYSTEMOPT(System


Optimization), SENDING(Force Sending)

NO(No), YES(Yes)

OFF(OFF), ON(ON)

10~800

10~800

100~600000

TCHFR(TCH Full Rate), TCHHR(TCH Half Rate), SDCCH8(SDCCH8),


MBCCH(Main BCCH), CBCCH(Combined BCCH), BCH(BCH),
BCCH_CBCH(BCCH+CBCH), SDCCH_CBCH(SDCCH+CBCH),
PBCCH_PDTCH(PBCCH+PDTCH), PCCCH_PDTCH(PCCCH+PDTCH),
PDTCH(PDTCH), DPDCH(Dynamic PDCH)

0~65535

0~65535

0~65535

0~65535

0~160

1~12

OFF(Off), ON(On)

1~100

1~60

NO(No), YES(Yes)

NO(No), YES(Yes)

NOTSENDING(Not sending), SENDINGPRO(sending according to


protocol), SENDING(unconditionally sending)

NOTSENDING(Not sending), SENDINGPRO(sending according to


protocol), SENDING(unconditionally sending)

NO(No), YES(Yes)

NO(No), YES(Yes)

1~1562

0~22

0~27

0~11

UNSUPPORT(Not Support), SUPPORT(Support)

NO(No), YES(Yes)

ERR_PFM_1E6(RECOVERY:1E-6), ERR_PFM_5E6(RECOVERY:5E-6),
ERR_PFM_1E5(RECOVERY:1E-5), ERR_PFM_5E5(RECOVERY:5E-5),
ERR_PFM_1E4(RECOVERY:1E-4), ERR_PFM_5E4(RECOVERY:5E-4),
ERR_PFM_1E3(RECOVERY:1E-3)

INCLK(Internal Clock), BSCCLK(Trace BSC Clock), EXCLK(External


Synchro Clock), IPCLK(IP Clock), TRANSCLK(Trace Trans Clock),
GPSCLK(Trace GPS Clock), UMCLK(Um Clock), PEERCLK(PEER
Clock)
HW_DEFINED(Huawei User-defined), PTP(PTP Protocol)

GCUa, GCGa

INT_CLK(Internal Clock), TRCBSC_CLK(Trace BSC Clock),


EXTSYN_CLK(External Sync clock), IP_TIME(IP Clock),
IP_TRANSFER(Trace Transport Clock), TRCGPS_CLK(Trace GPS
Clock), UM_CLK(Um Clock), PEER_CLK(Peer Clock)

0~255

cleared, uncleared

0~255

None

None

0~19
1~3

0~62

0~62

0~62

0~62

1~60

0~4095

0~4095

0~31

0~3

NONE(None), AINTFBLOCK(AInterf Block)

1~150000

BTS3002C, BTS3012A, BTS3006A


BTS3012(BTS3012), BTS3012AE(BTS3012AE),
BTS3006C(BTS3006C), BTS3012_II(BTS3012 II),
BTS3002E(BTS3002E), DBS3900_GSM(DBS3900 GSM),
BTS3900_GSM(BTS3900 GSM), BTS3900A_GSM(BTS3900A GSM),
DBS3036(DBS3036), BTS3036(BTS3036), BTS3036A(BTS3036A),
BTS3900_GSM_6RFC(BTS3900 GSM 6RFC),
BTS3900A_GSM_6RFC(BTS3900A GSM 6RFC),
BTS3036_6RFC(BTS3036 6RFC), BTS3036A_6RFC(BTS3036A
6RFC)
10000~50000

0~250

0~250

NO(No), YES(Yes)

1~1023

INACTIVE(Inactive), ACTIVE(Active)

BYSITE(By Site), BYCELL(By Cell)

0~100

L0_FORBID, L1_FORBID, L2_FORBID, L3_FORBID, L4_FORBID,


L5_FORBID, L6_FORBID, L7_FORBID, L8_FORBID, L9_FORBID

LOWERCASE, UPPERCASE, DIGIT, SPECIALCHARACTER

1~100

NO(No), YES(Yes)

BYNAME(By Name), BYID(By Index)

10~150

10~150

10~150

10~150

10~150

10~150

10~150

10~150

10~150

10~150

10~150

10~150

NO(No), YES(Yes)

0~335

NO(NO), YES(YES)

INNER(Internal RNC), EXTERNAL(External RNC)

ALL(ALL Type), ONLY_SSL(Only SSL Connection)

0~60

1~200

NO(NO), YES(YES)

1~28

1~60

NO(No), YES(Yes)

0~7

OFF(Off), ON(On), NOTSUPPORT(Not Support)

0dB, 2dB, 4dB, 6dB, 8dB, 10dB, 12dB, 14dB

None

DISABLE(Disable), ENABLE(Enable)

1~255

1~255

0~63

1~255

UNAVAILABLE(UNAVAILABLE), AVAILABLE(AVAILABLE)

VOICEINF, MR, CALLAPPENDINF, CALLINNERINF

0~100

OFF(Not Output), ON(Output)


RESINSUFF, UMABNORM, TRAFFREJECT, MSCREL, MSCDISCON,
BADQUALITY

0~100

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33,
AF41, AF42, AF43, EF

0~7

0~100

0~7

OFF(Not Output), ON(Output)

OFF(Not Output), ON(Output)


OFF(Not Output), MRHOFAIL(Preferentially Output MR of HO
Failure), MRHOLATEST(Preferentially Output MR of Latest HO)

COMMONUSRM(Common User Mode), SPECUSRM(Specified User


Mode)

ABNORMREC(Output Abnormal Records in BSC),


ALLBSCREC(Output All Records in BSC), ALLCELLREC(Output All
Records in Cells)
OFF(OFF), ON(ON)
OFF(Not Output), ALL(Output All), AINTF(Output A Interface
Signaling), ABISINTF(Output Abis Interface Signaling)

30~100

LU, SMS, CALL

0~100

OFF(Not Output), ON(Output)

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33,
AF41, AF42, AF43, EF

0~7

0~100

0~7

ON(ON), OFF(OFF)

40000~50000

5000~150000

1000~2000

400~600

7500~9500

80~120

3000~6000

500~2000

1~100

30~100

30~100

1~16777215

4BURST(4Burst), RLC/MAC(RLC/MAC)

NO(Cancel Control Flag), YES(Set Control Flag)

0~62

0~5

0~23

0~254
0,2,4,8,10,12,14,16,18,20,22,24,26
0~27,255

0~11,255

ON(ON), OFF(OFF)

NO(No), YES(Yes)

0~99
10~255
None

1~31

1~31

NT14_5K~0 NT12K~1 NT6K~2 T14_4K~3 T9_6K~4 T4_8K~5


T2_4K~6 T1_2K~7 T600_BITS~8 T1200_75

YEAR, MONTH, DAY

NOLIMIT(No Limit), LIMIT(Limit)

1~12

0~31

0~30

Inner(Inner), Extra(Extra)

0~2047

None

BYNAME(By Name), BYID(By Index)

0~255

0~255

0~255

0~255

350~556

580~600

433~555

580~600

0~32

500~60000

0~186

None

INACTIVE(Inactive), ACTIVE(Active)

None
None
None

1~1000

BSC, BTS

BTS, BSC, DXX, OTHER

0~27

0~11

0~7

0~3071

0~255

3~10

OFF(OFF), ON(ON)

None
0~35
None
LOGIC_IP(Logical IP Address)

0~16383

0~23

0~254

NO(Not Default DPC), YES(Default DPC)

DEFAULTPORT(Default 21 Port), CUSTOMPORT(Custom Port)

1~60

None
0~63
DISABLE(DISABLE), ENABLE(ENABLE)

NO(No), YES(Yes)

MON_1(No.1), MON_2(No.2), MON_3(No.3), MON_4(No.4),


MON_5(No.5), MON_6(No.6), MON_7(No.7), MON_8(No.8),
MON_9(No.9), MON_10(No.10), MON_11(No.11), MON_12(No.12),
MON_13(No.13), MON_14(No.14), MON_15(No.15),
MON_16(No.16), MON_17(No.17), MON_18(No.18),
MON_19(No.19), MON_20(No.20), MON_21(No.21),
MON_22(No.22), MON_23(No.23), MON_24(No.24),
MON_25(No.25), MON_26(No.26), MON_27(No.27),
MON_28(No.28), MON_29(No.29), MON_30(No.30),
MON_31(No.31)

SUN(Sunday), MON(Monday), TUE(Tuesday), WED(Wednesday),


THU(Thursday), FRI(Friday), SAT(Saturday)
None

None

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

0~15

NO(No), YES(Yes)

4~32

4~32

4~32

N0(No), YES(Yes)

0~255

1~30

1~30

1~30

1~30

16~1007

1~255

UNSUPPORT(Not Support), SUPPORT(Support)

0~63

1~10

1~30

1~30

0~127

1~30

1~30

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~63

0~70

1~100

1~20

2~255

2~255

2~255

2~255

1~30

1~30

1~100

0~3

0~7

0~7

1~20

0~7

0~63

0~70

0~70

0~70

0~10

0~19

0~63

0~63

1~20

0~10

0~19

1~20

0~100

0~100

0~63

0~63

0~300

0~255

1~255

0~63

0~63

0~63

0~63

0~63

0~63

0~63

0~63

0~255

0~255

0~255

CS1(CS1), CS2(CS2), CS3(CS3), CS4(CS4)

MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4),


MCS5(MCS5), MCS6(MCS6), MCS7(MCS7), MCS8(MCS8),
MCS9(MCS9)

MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4),


MCS7(MCS7), MCS8(MCS8), DAS5(DAS5), DAS6(DAS6),
DAS7(DAS7), DAS8(DAS8), DAS9(DAS9), DAS10(DAS10),
DAS11(DAS11), DAS12(DAS12)
MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4),
MCS7(MCS7), MCS8(MCS8), DAS5(DAS5), DAS6(DAS6),
DAS7(DAS7), DAS8(DAS8), DAS9(DAS9), DAS10(DAS10),
DAS11(DAS11), DAS12(DAS12), UNFIXED(UNFIXED)

CS1(CS1), CS2(CS2), CS3(CS3), CS4(CS4), UNFIXED(UNFIXED)

MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4),


MCS5(MCS5), MCS6(MCS6), MCS7(MCS7), MCS8(MCS8),
MCS9(MCS9), UNFIXED(UNFIXED)

NO(No), YES(Yes)

NO(No), YES(Yes)

0~5000

0~64

0~64

0~64

0~64

0~64

0~64

CLOSE(Close), OPEN(Open)

0~255

1~16777215
None
0~31

0~31

0~31

STP(STP), A(A), IUR_G(IUR_G), LB(LB)

0~186

0~182

0~128

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

0~1

10~150

10~150

10~150

10~150

10~150

10~150

1~60

0~12

2~10

NO(No), YES(Yes)

0(0), 1(1), 2(2), 4(4), 8(8), 16(16), 32(32), 64(64)

INACTIVE(Inactive), ACTIVE(Active)

0~335
0~335

0~63

0~63
0~63

0~63

1~3600

0~27

0~21

0~21

0~27

0~21

0~30

NO(NO), YES(YES)

None

None

None
None

None

None
0~335

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

0~100

NO(No), YES(Yes)

1~12
1(1), 2(2), 3(3), 4(4), 5(5), 6(6), 7(7), 8(8), 9(9), 10(10), 11(11),
12(12)
0~1

0~1,255

0~23

0~23,255

0~53

0~53,255

OFF(Off), ON(On)

FULL(FULL), HALF(HALF)

0~12

1~24

0~59

0~59

10~80

0~63

0~2047

0~2047

0~15

10~3600

LEVEL0(Preempt all dynamic TCHFs), LEVEL1(No preempt of


CCHs), LEVEL2(No preempt of service TCHF)

0~8

NO(No), YES(Yes)
NOTSUPPORT(Not Support), DDIVERSITY(DDIVERSITY),
DPBT(DPBT)
1~60

0~7

0~31
ACTIVE(ACTIVE TMU/MMU/IOMU/DOMU),
ACTIVESTANDBY(ACTIVE/STANDBY TMU), SLAVE1(SLAVE
TMU1/DOMU1), SLAVE2(SLAVE TMU2/DOMU2), UTRP(UTRP)
0~7

0~83

16~19

E1(E1), T1(T1)

None

0~49

0~49

NO(No), YES(Yes)

1~2147483646

year, month, day

year, month, day

year, month, date

year, month, day

1~31

1~255

1~255

0~11

NO(No), YES(Yes)

1~32

1~32

1~32

1~32

1~32

1~32

NO(Effect Later), YES(Effect Immediately)

NO(NO), YES(YES)

NO(No), YES(Yes)

0~31

0~31

DATE(Input with date), WEEK(Input with week), DATEWEEK(Input


with date and week)

1~15

OFF(OFF), ON(ON)

ERR_PFM_5E6(OCCUR:5E-6), ERR_PFM_1E5(OCCUR:1E-5),
ERR_PFM_5E5(OCCUR:5E-5), ERR_PFM_1E4(OCCUR:1E-4),
ERR_PFM_5E4(OCCUR:5E-4), ERR_PFM_1E3(OCCUR:1E-3),
ERR_PFM_5E3(OCCUR:5E-3)
0~63

NO(No), YES(Yes)

NO(No), YES(Yes)

NoPriority(No Priority), Priority4(Priority 4), Priority3(Priority3),


Priority2(Priority 2), Priority1(Priority 1), Priority0(Priority 0),
PriorityB(Priority B), PriorityA(Priority A)
0~7

0~7

2~4094
JAN(January), FEB(February), MAR(March), APR(April), MAY(May),
JUN(June), JUL(July), AUG(August), SEP(September),
OCT(October), NOV(November), DEC(December)
None

NO(No), YES(Yes)

ENABLED(Enabled), DISABLED(Disabled)

A5/0~0 A5/1~1 A5/2~2 A5/3~3 A5/4~4 A5/5~5 A5/6~6 A5/7

AUTO(Automatic), PLAINTEXT(Plain Text), ENCRYPTED(SSL


Encrypted)

AUTO(Auto), PLAINTEXT(Plain Text), ENCRYPTED(SSL Encrypte)

NO(No), YES(Yes)

1~65535

0~65535

0~65535

1~31

-990~400

JAN(Jan.), FEB(Feb.), MAR(Mar.), APR(Apr.), MAY(May), JUN(Jun.),


JUL(Jul.), AUG(Aug.), SEP(Sep), OCT(Oct.), NOV(Nov.), DEC(Dec)

0(0), 2(2), 4(4), 6(6)

hour, min

1~31

8~255

1~31

DISABLED(Prohibit to Use), ENABLED(Available)

DISABLED(Prohibit to Use), ENABLED(Available)

0~100

OFF(OFF), ON(ON)

OFF(Off), ON(On)

1~255

0~63

0~100

OFF(Off), ON(On)

OFF(Off), ON(On)

0~100

NO(No), YES(Yes)

M3UA_SGP(M3UA SGP), M3UA_IPSP(M3UA IPSP),


M3UA_SS7SP(M3UA SS7SP), M3UA_SP(M3UA SP)

M3UA_ASP~0||(M3UA_ASP)$$(M3UA_ASP)**
M3UA_IPSP(M3UA_ASP)** M3UA_IPSP~2||(M3UA_IPSP)$$
(M3UA_IPSP)

0~63

OFF(Off), ON(On)

1~4294967295

NO(No), YES(Yes)

O1E3_R5E4(OCCUR:1E-3,
O5E4_R1E4(OCCUR:5E-4,
O1E4_R5E5(OCCUR:1E-4,
O5E5_R1E5(OCCUR:5E-5,
O1E5_R5E6(OCCUR:1E-5,
O5E6_R1E6(OCCUR:5E-6,

RECOVERY:5E-4),
RECOVERY:1E-4),
RECOVERY:5E-5),
RECOVERY:1E-5),
RECOVERY:5E-6),
RECOVERY:1E-6)

OFF(OFF), ON(ON)

0~63

0~7

0~7

2~4094

1~2147483646

500~60000

CLOSE(Close), OPEN(Open)

0~255

hour, min, sec

hour, min, sec

year, month, date, hour, min, sec

hour, min

ONE_BY_ONE(Execute One by One), PARALLEL(Parallel Execute)

year, month, date, hour, min, sec

year, month, day, hour, min, sec

HOUR, MIN, SEC

year, month, day

hour, min, sec

LOGINEVENT(Login Event), MANAGEEVENT(Management Event),


AUTHEVENT(Authentication Event), OTHEREVENT(Other Event)

hour, min, sec


SUN(Sunday), MON(Monday), TUE(Tuesday), WED(Wednesday),
THU(Thursday), FRI(Friday), SAT(Saturday)

FIRST(First), SECOND(Second), THIRD(Third), FOURTH(Fourth),


LAST(Last)

None

None

VOLTAGE(Voltage), CURRENT(Current)

None

None

None

None

VOLTAGE(Voltage), CURRENT(Current)

None

None

None

None

VOLTAGE(Voltage), CURRENT(Current)

None

None

None

None

VOLTAGE(Voltage), CURRENT(Current)

None

None

NoExclusive(NoExclusive), Exclusive(Exclusive)

0~100

0~63

0~63

2048~5047

None

5048~8047

None

2048~5047

None

CLOSE(Close), OPEN(Open)

NO(No), YES(Yes)

EM0(EM0), EM1(EM1)

60sec(60sec), 120sec(120sec), 240sec(240sec), 480sec(480sec),


960sec(960sec), 1920sec(1920sec), 3840sec(3840sec),
7680sec(7680sec)

TYPE1(TYPE1), TYPE2(TYPE2), TYPE3(TYPE3)

Normal_cell(Normal cell), DualTS_ExtCell(Double Timeslot


Extension Cell)

SEND(SEND), NOTSEND(NOTSEND)

0~255

NO(No), YES(Yes)

NO(No), YES(Yes)

OFF(OFF), ON(ON)

OFF(Off), ON(On)

0~63

PLUS_1(Current FanSpeed Plus 1), MINUS_1(Current FanSpeed


Minus 1)
HIGH_SPEED, LOW_SPEED

55~100
CONTINUOUS(Continuous), DISCRETE(Discrete),
DUTY_RATIO(Duty Ratio)
NORMAL_FAN(Normal Fan), IND_FAN(Independent Fan)
NO_SPEED_ADJUSTMENT(No Speed Adjustment),
HW_AUTO_TEMPERATURE_CONTROL(Auto Temperature Control),
SPECIFY_RATE(Specify Rate), SOFTWARE_CONTROL(Software
Control)
IND_FAN(Independent Fan), NORMAL_FAN(Normal Fan)

0~100

NO(No), YES(Yes)

OFF(Off), ON(On)

CLOSE(Close), OPEN(Open)

OFF(OFF), ON(ON)

0~100

0~1999

0~1999
0~1999
0~1999

0~1999

10~1999

2~1999

0~62

0~62

0~100

None(None), 16bit(16bit), 32bit(32bit)

None(None), 16bit(16bit), 32bit(32bit)

ON, OFF

432~575

AUTO(Auto), MANU(Manu)

AUTO(Auto), MANU(Manu)

0~7

0~7

0~1

0~16383

0~49

0~3

0~7

0~7

0~15

RSCP(RSCP), EcN0(Ec/N0)

0~15

0~63

0~511

1~1000

NO(No), YES(Yes)

0~1000

0~1000

0~1000

0~1000

0~1000

0~1000

0~1000

NO_FH(No frequency hopping), BaseBand_FH(Baseband


frequency hopping), RF_FH(RF frequency hopping),
Hybrid_FH(Hybrid frequency hopping)

None

None

None

None

txt(.txt File), csv(.csv File)

0~32

FALSE(Failed), TRUE(Succeeded)

NO(No), YES(Yes)

INACTIVE(Inactive), ACTIVE(Active)

0~100

0~65534

0~65534

DISABLE(DISABLE), ENABLE(ENABLE)

60~65534

60~65534

FIX_16K_ABIS(Fix Abis), FLEX_ABIS(Flex Abis),


SEMI_ABIS(Semisolid Abis)

OFF(Off), ON(On)

OFF(Off), ON(On)

0~65535

0~65535

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)
OFF(OFF), ON(ON)

0~20

0~20

0~20

0~20

0~20

0~20

0~20

0~20

0~200

CLOSE(Close), OPEN(Open)

0~19

INDOOR(Indoor), OUTDOOR(Outdoor)

None

None

None

None

None

None

None

OPEN(Open), CLOSE(Close)

1~300

0~30

Close(Close), Open(Open)

NO(No), YES(Yes)

NO(No), YES(Yes)

0~31

0~23

1~30

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

128~1024

0~255

-2715647~2715647

NO(No), YES(Yes)

0~1023

ONTIME(Fixed Time), DAILY_T(Day Based Scheduling),


DAILY_C(Day Based Duration), WEEKLY_T(Week Based
Scheduling), WEEKLY_C(Week Based Duration),
MONTHLY_T(Month Based Scheduling), MONTHLY_C(Month Based
Duration)

ONTIME(Fixed Time), RELATIVE_T(Relative Time)

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

0~1023

NO(No), YES(Yes)

0~65535

PGSM900(PGSM900), EGSML25(EGSM<L25>),
EGSM35M(EGSM<35M>), RGSML25(RGSM<L25>),
GSM900_RGSM39M(GSM900_RGSM<39M>),
DCS1800(DCS1800), PCS1900(PCS1900), GSM850(GSM850),
EGSM24M(EGSM<24M>), DCS1800_L(DCS1800<L50M>),
DCS1800_H(DCS1800<H50M>)

0~100

0~1023

LOOSE(Loose), TIGHT(Tight)

None

MainDiversity(MainDiversity),
MaximumMeanValue(MaximumMeanValue)

NO(No), YES(Yes)

May_Use(May Use), Shall_Use(Shall Use), Shall_NOT_Use(Shall


not Use)

0~23

0~23

0~255

0~254

TXT(Plain Text Type), CSV(CSV Type)

0~33
1~33
0~33

0~255

0~600

1~32

0~255

0~600

1~32

0~200000

0~200000

0~100

0~100

0~200000

0~100

0~200000

0~100
0~100
0~200000
0~200

0~100

A0, U1

0~31

hour, min

0~100

OFF(OFF), ON(ON)

hour, min

NO(Not Support), YES(Support)

OFF(Off), ON(On)

DEG(DEG), SEC(SEC)

NO(No), YES(Yes)

NO(No), YES(Yes)

OFF(Disable the golbal route management), ON(Enable the


golbal route management)

4~32

NO(Not Support), SupportAsInnPcu(Support As Inner Pcu),


SupportAsExtPcu(Support As Outer Pcu)

NO(Not support), SupportAsInnPcu(Support as built-in PCU),


SupportAsExtPcu(Support as external Pcu)

0dB(0dB), 2dB(2dB), 4dB(4dB), 6dB(6dB), 8dB(8dB),


10dB(10dB), 12dB(12dB), 14dB(14dB)

GPRS(GPRS Channel), EGPRSNORCH(EGPRS Normal Channel),


EGPRSPRICH(EGPRS Priority Channel), EGPRSSPECH(EGPRS
Special Channel), NONGPRS(Non-GPRS Channel)

DB110(-110dB), DB108(-108dB), DB106(-106dB), DB104(104dB), DB102(-102dB), DB100(-100dB), DB98(-98dB), DB96(96dB), DB94(-94dB), DB92(-92dB), DB90(-90dB), DB88(-88dB),
DB86(-86dB), DB84(-84dB), DB82(-82dB), DB80(-80dB), DB78(78dB), DB76(-76dB), DB74(-74dB), DB72(-72dB), DB70(-70dB),
DB68(-68dB), DB66(-66dB), DB64(-64dB), DB62(-62dB), DB60(60dB), DB58(-58dB), DB56(-56dB), DB54(-54dB), DB52(-52dB),
DB50(-50dB), DB48(-48dB), nouse(no use)

10sec(10sec), 20sec(20sec), 30sec(30sec), 40sec(40sec),


50sec(50sec), 60sec(60sec), 70sec(70sec), 80sec(80sec),
90sec(90sec), 100sec(100sec), 110sec(110sec), 120sec(120sec),
130sec(130sec), 140sec(140sec), 150sec(150sec),
160sec(160sec), 170sec(170sec), 180sec(180sec),
190sec(190sec), 200sec(200sec), 210sec(210sec),
220sec(220sec), 230sec(230sec), 240sec(240sec),
250sec(250sec), 260sec(260sec), 270sec(270sec),
280sec(280sec), 290sec(290sec), 300sec(300sec),
310sec(310sec), 320sec(320sec), nouse(no use)

0~7

0db(0db), 10db(10db), 20db(20db), 30db(30db), 40db(40db),


50db(50db), 60db(60db), infinity(infinity), nouse(no use)

GPS(GPS), GLONASS(Glonass), GPSGlonass(GPSGlonass)

1~60

NO(No), YES(Yes)

0~100000000

0~100000000

0~65534

None

0~512

0~2047
IP(IP)

LAC_CI(CELL IMME), PLMN(ALL), LAC(LAC), CI(CELL)

0~100
1~15

0~3

UNSUPPORT(Not Support), SUPPORT(Support)

ECHOREPLY, UNREACH, SOURCEQUENCH, REDIRECT, ECHO,


ROUTERADVERT, ROUTERSOLICIT, TIMXCEED, PARAMPROB,
TSTAMP, TSTAMPREPLY, IREQ, IREQREPLY, MASKREQ, MASKREPLY

None

None

NO(No), YES(Yes)

0~255

0~600

1~32

0~255

1~32

NO(NO), YES(YES)

NO(NO), YES(YES)

1000~600000

0~62

1~16

1~16

0~65535

0~65535

DCS1800, PCS1900

1~14

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(NO), YES(YES)

NO(No), YES(Yes)

1~10

UNSUPPORT(Not Support), SUPPORT(Support)

SysOpt(System optimization), OSubcell(Overlaid subcell),


USubcell(Underlaid subcell), NoPrefer(No preference)

NO(No), YES(Yes)

0~63

0~63

BYCELLNAME(By cell name), BYCGI(By CGI)

None

HOALGORITHM1(Handover algorithm I),


HOALGORITHM2(Handover algorithm II)

NO(No), YES(Yes)

0~16

0~16

0~63

1~32

1~32

0~49

1~32

FREE(Free), INCELL(Intra-cell), OUTCELL(Outgoing cell),


OUTST(Outgoing site), OUTBSC(Outgoing BSC),
OUTSYS(Outgoing system), SPCELL(Specified cell)

0~127

0~61

Pre_2G_Cell(Preference for 2G cell), Pre_3G_Cell(Preference for


3G cell), Pre_2G_CellThres(Preference 2G cell by thresh)

0~255

0~63

0~63

BaseBand_FH(BaseBand FH), RF_FH(RF FH)

NO(Not StartUp), YES(StartUp), NONE(None)

0~63

OFF(Off), ON(On)

0~63

0~23

NO_FH(No Frequency Hopping), BaseBand_FH(Baseband


Frequency Hopping), RF_FH(RF Frequency Hopping)

0~63

1~60

0~63

NO(No), YES(Yes)

1~32

1~32

1~32

SINGLEHOST(SINGLEHOST), PRIMHOST(PRIMHOST),
SLAVEHOST(SLAVEHOST)

SINGLEHOST(Single Host), PRIMHOST(Primary Host),


SLAVEHOST(Slave Host)

0~63

0~63

NO_HPANT(No), YES_HPANT(Yes), NONE(None)

NO_HPANT(No), YES_HPANT(Yes)

0~5

1~14

NO(NO), YES(YES)

350~556

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

May_Use(May Use), Shall_Use(Shall Use), Shall_NOT_Use(Shall


not Use)

0~63

0~23

OFF(Off), ON(On)

0~254

SBFD(SINGLE_HOP), MBFD(MULTI_HOP)

-99~70

0~30

DISABLE(DISABLE), ENABLE(ENABLE)

CLOSE(Close), OPEN(Open)

None

None

0~1000

0~1000

0~1000

0~1000

1~30

180~1260

1~60
E1PORT0(E1 PORT0), E1PORT1(E1 PORT1), E1PORT2(E1 PORT2),
E1PORT3(E1 PORT3), OPTICALPORT0(OPTICAL PORT0),
OPTICALPORT1(OPTICAL PORT1)
MAINDOMU(MAIN DOMU), SLAVEDOMU1(SLAVE DOMU1),
SLAVEDOMU2(SLAVE DOMU2)
60~600

0~23

0~23

NO(No), YES(Yes)

0~20

1~4

0~14

0~14

0~63

NO(No), YES(Yes)

0~20

OFF(Not Allowed), ON(Allowed)

OFF(Not Allowed), ON(Allowed)

0~23

0~20

0~23

0~31

NO(No), YES(Yes)

2~600

0~63

0~63

0~22

0~22

0~63

0(Max. optimized MAIO), 1(Randomization MAIO)

5~40

NO(No), YES(Yes)

0~63

0~30

0~20

0~16

0~63

2~600

0~50

0~10

0~63

0~160

0~23

NO(No), YES(Yes)

OFF(Not Allowed), ON(Allowed)

0~63
NO(Disabled in OL and UL subcell), UNDER(Enabled in UL
subcell), INNER( Enabled in OL subcell), YES(Enabled in OL and
UL subcell)

NO(No), YES(Yes)

0~23

NO(NO), YES(YES), NULL(NULL)

DISABLE(DISABLE), ENABLE(ENABLE)

44~1024

0~63

0~63

0~63

1~30

1~30,100~32767

0~65535

0~255

0~255

0~63

BYNAME(By Name), BYID(By Index)

BYNAME(By name), BYID(By index), BYCGI(By CGI)

BYNAME(By Name), BYID(By Index)

BYNAME(By Name), BYID(By Index)

BYNAME(By Name), BYID(By Index)

BYIDX(By Index), BYNAME(By Name)

BYNAME(By Name), BYID(By Index)

BYNAME(By Name), BYID(By Index)

0~255

BYTLLI(By TLLI), BYIMSI(By IMSI)

BYCELL(By Cell), BYBSC(By BSC)

YES(Yes), NO(No)

0~15

Positive(Positive), Minus(Minus)

0~125

NO(Not Report), YES(Need Report)

0~32

None

1000~30000

NO(NO), YES(YES)

NO(Not Support), YES(Support)

NO(No), YES(Yes)

0~254

1~5

NO(No), YES(Yes)

NO(No), YES(Yes)

0~255

NO(NO), YES(YES)

0~255

None

None

500~60000

0~8

1~30

0~360

0~62

NO(NO), YES(YES)

1~32

1~32

CELLCAPCLASS, NACCRELATED

CLOSE(Close), OPEN(Open)

0~39

0~39

0~50

0~3

0~3

0~2

TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11,
TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21,
TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

NO(No), YES(Yes)

NO(No), YES(Yes)

0~2047

None

NO(No), YES(Yes)

1~255

0~63

0~100

0~23
0~335
0~15

Degree(Degree), D_min_sec(Degree Minute Second)

NO(No), YES(Yes)

0~23
0~27
0~254
0~11
2~3600

0~127

INTBANI(INTBANI), INTBANII(INTBANII)

0~127

0~255

1~16

1~16

NO(No), YES(Yes)

NO(No), YES(Yes)

48~115

48~115

48~115

48~115

48~115

48~115

0~60

1~31

NO(No), YES(Yes)

1~100

NO(No), YES(Yes)

NO(No), YES(Yes)

1~49

0~49

1~49

1~91

0~91

1~91

NO(No), YES(Yes)

Service-based(Service-based), Load-based(Load-based),
Dynamic-based(Dynamic Service/Load-based), CnServicebased(CN Service-based), OFF(OFF)

1~10

1~240

0~31

0~63

500~60000

500~60000

NO(No), YES(Yes)

NO(No), YES(Yes)

500~60000

NO(No), YES(Yes)

0~49

1~255

0~91

0~255

0~31

1~1440

30~1024

NO(No), YES(Yes)

None

None
None

None

None

None

None

None

None

None
None

None
None
None

None

None

None

None

None

0~100

0~100

No_HC(No_HC), UDP/IP_HC(UDP/IP_HC),
RTP/UDP/IP_HC(RTP/UDP/IP_HC)

No_HC(No_HC), UDP/IP_HC(UDP/IP_HC),
RTP/UDP/IP_HC(RTP/UDP/IP_HC)
0~5
0~5
0~12999

IP_OVER_FE/GE, IP_OVER_E1

IP_OVER_FE/GE(IP_OVER_FE/GE), IP_OVER_E1(IP_OVER_E1)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(No), YES(Yes)

UNSUPPORT(Not Support Reducy), SUPPORT(Support Reducy)

UNSUPPORT(Not Support Reducy), SUPPORT(Support Reducy)

NO(No), YES(Yes)

NO(NO), YES(YES)

NO(Not support), YES(Support)


NO(NO), YES(YES)
NO(Not support), YES(Support)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(NO), YES(YES)

NO(Not support), YES(Support)

STATIC(Static), DYNAMIC(Dynamic)

NO(NO), YES(YES)

NO(NO), YES(YES)

YES(Configure), NO(Not Configure)

NO(NO), YES(YES)

NO(No), YES(Yes)

NO(No), YES(Yes)

YES(YES), NO(NO)

NO(NO), YES(YES)

NO(NO), YES(YES)

NOT_CONFIG(NOT CONFIGURED), CONFIG(CONFIGURED)

1~64

1~30

TRUE(Support), FALSE(Not Support)

0~65535

ABIS(Abis Interface), A(A Interface), ATER(ATER Interface),


IUR_G(IUR_G Interface)

PPP(PPP), MP(MP)

OVERLAID(Overlaid Subcell), UNDERLAID(Underlaid Subcell),


NONE(None)

CONVERT0(Only convert at UL), CONVERT1(Only convert at OL),


CONVERT2(UL first and convert allowed), CONVERT3(OL first and
convert allowed)

1~32

1~32

Normal_cell(Normal Cell), Concentric_cell(Concentric Cell),


EDB_cell(Enhanced Double Frequency Cell)

OFF(OFF), ON(ON)

Hexadecimal(Hex decimal), Character_String(Character String)

None

None

NULL, 1byte, 16byte, 64byte

OFF(OFF), ON(ON)

Hexadecimal(Hex decimal), Character_String(Character String)

None

None

NULL, 1byte, 16byte, 64byte

OFF(OFF), ON(ON)

Hexadecimal(Hex decimal), Character_String(Character String)

NULL, 1BYTE, 16BYTE, 64BYTE

None

None

ZERO(zero), SPACE(space)

DISABLE(Disable), ENABLE(Enable)

1~255

DENY(Deny), ALLOW(Allow)

NOT-INDICATE-END(NOT-INDICATE-END), INDICATEEND(INDICATE-END)

0~63

1~30

1~65533,65535

1~65533,65535

STATIC_LACP, MANUAL_AGGREGATION

None

0~90

0~90

0~59

0~9

0~59
-90000000~90000000
None

1~100

0~100

0~10000

0~15

0~15

1, 2, 3, 4

1, 2, 3, 4

0~100

0~300

0~300

CLOSE(Close), PSDOWN(PS Downspeeding), AMRC(AMRC),


CSPH(CS Preference TCHH), CSFHHO(CS TCHF-TCHH HO)

CLOSE(Close), PSDOWN(PS Downspeeding), AMRC(AMRC),


CSPH(CS Preference TCHH), CSFHHO(CS TCHF-TCHH HO)

CLOSE(Close), PSDOWN(PS Downspeeding), AMRC(AMRC),


CSPH(CS Preference TCHH), CSFHHO(CS TCHF-TCHH HO)
0~186
0~7
ON(ON), OFF(OFF)
INFO(Information Level), WARN(Warn Level), ERR(Error Level),
AST(Assert Level)
CRITICAL(Critical), MAJOR(Major), MINOR(Minor)

NO(Not Support), YES(Support), NONE(Invalid)

NO(No), YES(Yes)

0~63

1~32

1~32

IP, Abis_IP

OAM, TDM_Switching, GCP, RGCP, MCP, GTC, GPCU, IP, FR, HDLC,
TDM, GbIP, Abis_TDM, Ater_TDM, Pb_TDM, A_TDM, Abis_IP, SAU

TDM_Switching, GCP, RGCP, MCP, GTC, GPCU, IP, FR, HDLC, TDM,
GbIP, Abis_TDM, Ater_TDM, Pb_TDM, A_TDM, Abis_IP

A/Gb, Abis/Ater/Pb/Gb
5120~5375

0~99

90~99

70~95
0~17407

DIFFERENCE, ALL

64K(64Kbit/s), 2M(2Mbit/s)
None

None

TS1(Time_slot_1), TS2(Time_slot_2), TS3(Time_slot_3),


TS4(Time_slot_4), TS5(Time_slot_5), TS6(Time_slot_6),
TS7(Time_slot_7), TS8(Time_slot_8), TS9(Time_slot_9),
TS10(Time_slot_10), TS11(Time_slot_11), TS12(Time_slot_12),
TS13(Time_slot_13), TS14(Time_slot_14), TS15(Time_slot_15),
TS16(Time_slot_16), TS17(Time_slot_17), TS18(Time_slot_18),
TS19(Time_slot_19), TS20(Time_slot_20), TS21(Time_slot_21),
TS22(Time_slot_22), TS23(Time_slot_23), TS24(Time_slot_24),
TS25(Time_slot_25), TS26(Time_slot_26), TS27(Time_slot_27),
TS28(Time_slot_28), TS29(Time_slot_29), TS30(Time_slot_30),
TS31(Time_slot_31)

0~40

40~80

LUCENT_MODE, HUAWEI_MODE, ALCATEL_MODE


8K(8Kbit/s), 16K(16Kbit/s), 32K(32Kbit/s), 64K(64Kbit/s),
2M(2Mbit/s)
M3UA_MASTER_MOD(M3UA_MASTER_MOD),
M3UA_SLAVE_MOD(M3UA_SLAVE_MOD)

B0000(B0000),
B0100(B0100),
B1000(B1000),
B1100(B1100),

B0001(B0001),
B0101(B0101),
B1001(B1001),
B1101(B1101),

B0010(B0010),
B0110(B0110),
B1010(B1010),
B1110(B1110),

B0011(B0011),
B0111(B0111),
B1011(B1011),
B1111(B1111)

B0000(B0000),
B0100(B0100),
B1000(B1000),
B1100(B1100),

B0001(B0001),
B0101(B0101),
B1001(B1001),
B1101(B1101),

B0010(B0010),
B0110(B0110),
B1010(B1010),
B1110(B1110),

B0011(B0011),
B0111(B0111),
B1011(B1011),
B1111(B1111)

0~100

RANDOMALG(Random Algorithm), OTHERALG(MS ID Algorithm)

1~10

0~1000

NO(NO), YES(YES)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

0~127

0~255

0~63

1~255

1~63

1~16

0~63

NO(NO), YES(YES)

FORBID(Forbid), PERMIT(Permit)

0~63

0~100

0~100

NO(No), YES(Yes)

NOTSTADYNPDCH(Not count dynamic PDCH),


DYNPDCHASOCCUPY(Count dynamic PDCH(Occupy)),
DYNPDCHASIDLE(Count dynamic PDCH(Idle))
OFF(OFF), ON(ON)

0~65534

None

None

None
None
0~1023
0~1

0~35

0~35

None

None

None

OFF(Unlock), ON(Lock)

1024~65535

LFB(Load from OMU and write flash), CL(Consult Load)


NORMMODE(Normal Mode), RAPMODENOSERV(Rapid Mode<No
service>), RAPMODERESSERV(Rapid Mode<Reserve BCCH trx>)
30~100

30~100

NO(NO), YES(YES)

0~988

0~5,8~27

30~100

30~100

ON, OFF

PFM_RESULT, HOST_PFM_RESULT, ACTIVE_DEF_MEAS_FILE,


STANDBY_DEF_MEAS_FILE, PFM_SWITCHS, HISTORY_ALARM,
HISTORY_FAULT, ALM_SYSTEM_CFG, SECURITY_LOG, OPT_LOG,
OMU_LOG, BSC_CFG_MML, CELL_BASIC_INFO, BSC_SERIES_NO,
DB_BAK, MEM_DB_BAK, BTS_BASIC_INFO, BTS_CHECK_LOG,
BTS_DEBUG_LOG, BTS_CHR_LOG, TRX_LOG, BTS_NET_TABLE,
DEBUG_LOG, LAST_WORD, DSP_DEBUG_LOG, HOST_LOG,
2G_CHR_LOG, 2G_UNILATERAL_CONNECT, BSC_INFO, GCSR_LOG,
GPSR_LOG, AIDG_LOG, BIOS_LOG

COMLOG(Common Log), CMPLOG(Compress Log)

None

0~180

0~180

0~59

0~9

0~59
-180000000~180000000
None
1~3

BYLOCAL(By Local Loop), BYREMOTE(By Remote Loop)

OFF(OFF), ON(ON)

LOOPTYPE_TDM(Line Loop), LOOP_TYPE_LVDS(LVDS Loop),


LOOPTYPE_MCC(MCC Loop)
0~100

MSC(MSC Direction), MS(MS Direction)

NSSAINTF(NSS Interface Unit), NSSTCTOABIS(NSS TC(Near Abis


Interface)), NSSTCTOA(NSS TC(Near A Interface)),
NSSTNUTOABIS(NSS TNU(Near Abis Interface)), NSSTNUTOA(NSS
TNU(Near A Interface)), NSSATERINTF(NSS Ater Interface Unit),
BSSATERINTF(BSS Ater Interface Unit), BSSTCTOABIS(BSS
TC(Near Abis Interface)), BSSTCTOA(BSS TC(Near A Interface)),
BSSTNUTOABIS(BSS TNU(Near Abis Interface)), BSSTNUTOA(BSS
TNU(Near A Interface)), BSSABISINTF(BSS Interface Unit),
BTSTMU(TMU/PTU), BTSTRUDSP(TRU DSP)

NO_LOOP(No loop), REMOTE_LOOP(Remote loop),


LINE_REM_LOOP(Line remote loop), LOCAL_LOOP(Local loop),
PAYLOAD_LOOP(payload loop), SIN_CHN_LOC(single channel local
loop), SIN_CHN_REM(single channel remote loop)

NO_LOOP(NO_LOOP), LOCAL_LOOP(LOCAL_LOOP),
REMOTE_LOOP(REMOTE_LOOP)

60~600

1~100

NO(No), YES(Yes)

NO(NO), YES(YES)

OFF(Off), ON(On)

OFF(Off), ON(On)

NO(NO), YES(YES)

NO(NO), YES(YES)

E1(E1 Loopback), TIMESLOT(Timeslot Loopback)

0~988

0~988,1024~1535

0~988,1024~1535

0~5,8~27

Hub(Hub), Leaf(Leaf)

IR(IR), LA(LA)

DISABLE(DISABLE), ENABLE(ENABLE)

350~556

CLOSE(Close), PSDOWN(PS Downspeeding), AMRC(AMRC),


CSPH(CS Preference TCHH), CSFHHO(CS TCHF-TCHH HO)
EXCLUDE(Exclude List Command), INCLUDE(Include List
Command)
HORIZONTAL(HORIZONTAL), VERTICAL(VERTICAL)

HORIZONTAL(HORIZONTAL), VERTICAL(VERTICAL)

APPLICATION(Application Program), SCNDCPU_PROG(Secondary


Thread Program), BOOTROM(BOOTROM Program), DATA(Data
file), DSP(DSP Program), FAN(Fan Program)
OPTLOG(Operation Log), SECLOG(Security Log)

OPTLOG(Operation Log), SECLOG(Security Log)

-99~70

-99~99

2~255

2~255

2~255

2~255

0~12

14(1.4), 15(1.5), 16(1.6), 18(1.8), 20(2.0), 22(2.2), 24(2.4),


26(2.6), 28(2.8), 30(3.0), 33(3.3), 36(3.6), 88(8.8)

18(1.8), 20(2.0), 22(2.2), 24(2.4), 26(2.6), 28(2.8), 30(3.0),


32(3.2), 35(3.5), 38(3.8), 41(4.1), 45(4.5), 88(8.8)

DISABLE(DISABLE), ENABLE(ENABLE)

1024~65535

0~8191

0~100

0~100

CA_MA(CA+MA), Frequency_List(Frequency List),


OPTIMIZED_CA_MA(Optimized CA+MA)

0~499

NO(No), YES(Yes)

NO(No), YES(Yes)

hour, min

0~15

hour, min

None

None

0~35

0~1

0~9999

0~11

0~11

0~11

0~11

0~11

0~11

0~11

0~11

0~11

0~11

0~11

0~11

0~2000

0~2000

0~2000

0~2000

0~2000

0~2000

None

None

None

None

None

None
None
None
None

None

None

None

None

0~32

0~254

1~1562

1~20

0~5

0~5

0~20

1~2

1~2

24~1031

50~200

1~1500

1~1500

1~255

10000~150000

1~1000

0~254

0~100

0~8

0~100

0~5

1~255

1C(0.01C), 2C(0.02C), 3C(0.03C), 4C(0.04C), 5C(0.05C),


6C(0.06C), 7C(0.07C), 8C(0.08C), 9C(0.09C), 10C(0.10C),
11C(0.11C), 12C(0.12C), 13C(0.13C), 14C(0.14C), 15C(0.15C),
16C(0.16C), 17C(0.17C), 18C(0.18C), 19C(0.19C), 20C(0.20C),
21C(0.21C), 22C(0.22C), 23C(0.23C), 24C(0.24C), 25C(0.25C),
26C(0.26C), 27C(0.27C), 28C(0.28C), 29C(0.29C), 30C(0.30C),
31C(0.31C), 32C(0.32C), 33C(0.33C), 34C(0.34C), 35C(0.35C),
36C(0.36C), 37C(0.37C), 38C(0.38C), 39C(0.39C), 40C(0.40C),
41C(0.41C), 42C(0.42C), 43C(0.43C), 44C(0.44C), 45C(0.45C),
46C(0.46C), 47C(0.47C), 48C(0.48C), 49C(0.49C), 50C(0.50C),
51C(0.51C), 52C(0.52C), 53C(0.53C), 54C(0.54C), 55C(0.55C),
56C(0.56C), 57C(0.57C), 58C(0.58C), 59C(0.59C), 60C(0.60C),
61C(0.61C), 62C(0.62C), 63C(0.63C), 64C(0.64C), 65C(0.65C),
66C(0.66C), 67C(0.67C), 68C(0.68C), 69C(0.69C), 70C(0.70C),
71C(0.71C), 72C(0.72C), 73C(0.73C), 74C(0.74C), 75C(0.75C),
76C(0.76C), 77C(0.77C), 78C(0.78C), 79C(0.79C), 80C(0.80C),
81C(0.81C), 82C(0.82C), 83C(0.83C), 84C(0.84C), 85C(0.85C),
86C(0.86C), 87C(0.87C), 88C(0.88C), 89C(0.89C), 90C(0.90C),
91C(0.91C), 92C(0.92C), 93C(0.93C), 94C(0.94C), 95C(0.95C),
96C(0.96C), 97C(0.97C), 98C(0.98C), 99C(0.99C)

5C(0.05C), 7C(0.07C), 10C(0.10C), 12C(0.12C), 15C(0.15C),


18C(0.18C), 20C(0.2C), 22C(0.22C), 25C(0.25C)

1~255

1_Times(1_Times), 2_Times(2_Times), 4_Times(4_Times),


7_Times(7_Times)

1_Times(1_Times), 2_Times(2_Times), 4_Times(4_Times),


7_Times(7_Times)

1_Times(1_Times), 2_Times(2_Times), 4_Times(4_Times),


7_Times(7_Times)

1_Times(1_Times), 2_Times(2_Times), 4_Times(4_Times),


7_Times(7_Times)

1~746

1~746

0~30

0~30

0~30

0~255

0~31

OFF(Off), ON(On)

0~255

1~24

0~32
2~255

0~32

1~999
0~511
None

0~3

0~31

0~31

0~2047

None

None

None

4,8

4,8

0~2047

None

0~62

OFF(Off), ON(On)

CLASS0(Class0), CLASS1(Class1), CLASS2(Class2)


0~7
0~7

None

None

NO(No), YES(Yes)

1~5

EnhMeasReport(Enhanced Measurement Report),


ComMeasReport(Common Measurement Report)

1~1000

1~8191

LocalMep(LocalMep), RemoteMep(RemoteMep)

LONG(Long List Head), SHORT(Short List Head)

LONG(LONG), SHORT(SHORT)

0~63

1~1562

0~49

0~63

10~3500

10~3500

0~2000

0~2000

0~2000

0~2000

0~2000

0~2000

10~3500

10~3500

0~63

60~3600

0~63

10~1000
10~1000

10~1000

10~1000

0~11

0~11

UP(upstream mirror), DOWN(downstream mirror)

None

None

50~95

SERVER(SERVER MOD), CLIENT(CLIENT MOD)

CHECK_ON_INDEPENDENT_PORT, CHECK_ON_PRIMARY_PORT,
CHECK_ON_STANDBY_PORT

MANUAL(Manual Handover), AUTO(Auto Handover), FREE(Freerun)

OFF(OFF), ON(ON)

GO(GSM), UO(UMTS), GU(GSM and UMTS)


FIXED(File of a Fixed Size), CYCLE(Periodical Generation of New
File)
MODE1(1:1 Protection Switching), MODE2(1+1 Unidirectional
Protection Switching), MODE3(1+1 Bidirectional Protection
Switching), MODE4(Y Line)

MODE1(Mode1), MODE2(Mode2), MODE3(Mode3)

MODE1(Mode1), MODE2(Mode2), MODE3(Mode3)

MODE1(Mode1), MODE2(Mode2), MODE3(Mode3)

MODE1(Mode1), MODE2(Mode2), MODE3(Mode3)

MODE1(Mode1), MODE2(Mode2), MODE3(Mode3)

MODE1(Mode1), MODE2(Mode2), MODE3(Mode3)

30MINS(30 Minutes), 60MINS(60 Minutes), 120MINS(120


Minutes), 240MINS(240 Minutes)
1~1440

0~12

0~600

0~100

0~100

0~3

0~167

0~167

MODE1_1, MODE2_1, MODE3_1, MODE4_1, MODE5_1, MODE6_1,


MODE16K

0~1

DISABLE(Disable), ENABLE(Enable)

MLPPP, MCPPP

0~27

0~11

NO(No), YES(Yes)

0~31

1~255

NOreport(Do not report), Twice_ps(Twice every second),


Once_ps(Once every second), Once_2s(Once every two second),
Once_4s(Once every four second)
4~30

4~30

OFF(Off), ON(On)

OFF(Off), ON_WITH_SDCCH(On with SDCCH),


ON_WITHOUT_SDCCH(On without SDCCH)

128~1500

1~16

OFF(Off), ON(On)

0~65535

1~10

0~1023

NO(No), YES(Yes)

OFFLOAD(Offload), NORMAL(Normal), UNAVAIL(Unavailable)

R98_or_below(R98 or below), R99_or_above(R99 or above)

5000~40000

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO(No), YES(Yes)

1_Times(1_Times), 2_Times(2_Times), 4_Times(4_Times),


7_Times(7_Times)

CLEAR(Cleared), LOP(Lockout of Protection), FS(Forcibly


switchover working link to protection link), MS(Manual
switchover from working link to protection link),
EXERS(Exercisely switch working link to protection link)
MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4),
MCS5(MCS5), MCS6(MCS6), MCS7(MCS7), MCS8(MCS8),
MCS9(MCS9)

10~80

0~254

0~63

0~255

1000~3000

1~600

0~31

ON(ON), OFF(OFF)

50~95
ALARM_METHOD(Alarm method), LOOP_METHOD(Loop method)
0~63
MET(Metric), IMP(Imperial)

500~1500

0~1500

256~1650

190~240

REPORT6(Report six), REPORT1(Report one), REPORT2(Report


two), REPORT3(Report three)

0~255

DISABLE(DISABLE), ENABLE(ENABLE)

0~10

0~15

NO(No), YES(Yes)

1~1500

1~1500

UDPMUX, ABISMUX, ATERMUX

0~12
1~512

1~3

5~254

34~254

29~254

OFF(Off), ON(On)

5~254

5~254

23~254

8~30

2~5

3~10

1~255

1~10

1~10

NO(No), YES(Yes)

None

None

None

None

None

None

None

None

None

None

None

None

NO(No), YES(Yes)

0~15

DISABLE(Disable), ENABLE(Enable)

0~5047

None

0~5047

None

0~5047

None

5048~8047

None

OFF(OFF), ON(ON)

0~65535

1~65533,65535

None

None

NO(No), YES(Yes)

NotSupport(Not Support), Support(Support)

NO(No), YES(Yes)

0~7

0~7

SELECTION0_PERM, SELECTION1_PERM, SELECTION2_PERM,


SELECTION3_PERM, SELECTION4_PERM, SELECTION5_PERM,
SELECTION6_PERM, SELECTION7_PERM

0~255

1~20

1~31

0~127

0~127

0~127

0~127

0~127

0~127

0~127

0~127

0~7

0~7

NC0(NC0), NC1(NC1), NC2(NC2)

NO(NO_DIRECT_CONNECT), YES(DIRECT_CONNECT)

None

0~60

None

None
None
None
INT(INT), INTB(INTB), NAT(NAT), NATB(NATB)

None

NMOI(Network Operation Mode I), NMOII(Network Operation


Mode II), NMOIII(Network Operation Mode III)

0~255

0~255

0~255

0~255

40~45

55~59

40~45

55~59

40~45

55~59

40~45

55~59

40~45

55~59

40~45

55~59

NO(No), YES(Yes)

0~255

0~255

0~255

0~255

0~7

0~100

0~255

0~255

NO(No), YES(Yes)

0~7

0~100

ABIS(Abis Interface), A(A Interface), BSC(Ater Interface on BSC),


TC(Ater Interface on TC), IUR_G(IUR_G Interface)

0~64

NO(No), YES(Yes)

0~70

1~1000

OFF(Not Allowed), ON(Allowed)


NODRX(NODRX), 0.24sec(0.24sec), 0.48sec(0.48sec),
0.72sec(0.72sec), 0.96sec(0.96sec), 1.20sec(1.20sec),
1.44sec(1.44sec), 1.92sec(1.92sec)

100~10000

100~10000

FORBID(Forbid), PERMIT(Permit)

400~700

CLOSE(Close), OPEN(Open)

1~255

10~255

1~10

0~31

0~31

0~1023

0~1023

NO(No), YES(Yes)

0~65534

0~65534

1~31

North_latitude(North latitude), South_latitude(South latitude)


0~65534

0~1023

0~30

0~30

1~255

0~100

0~100

0~100

0~100
0~100
0~63

OFF(OFF), ON(ON)

BYCELL(By CELL), BYTRX(By TRX)

SITE(SITE), CELL(CELL), BOARD(BOARD)


0~499
0~499
ALL(Shield by Alarm ID), BOARD(Shield by Board), PORT(Shield
by Port), DSP(Shield by DSP)
BTS(BTS), CELL(CELL), LOC(LOC), BOARD(BOARD), PORT(PORT)

CELL(Cell), TRX(TRX), CHN(Channel)

OFF(OFF), ON(ON)

NO(No), YES(Yes)

NO(No), YES(Yes)

OFF(OFF), ON(ON)

4~255

0~63

0~256

0~256

0~7

0~7

2~4094

0~96

None

None

None

1~16777215

1~16777215
0~4
PRIM(Primary Operator), SEC(Secondary Operator)

0~3

OPINDEX0, OPINDEX1, OPINDEX2, OPINDEX3

BYCICRANGE(BY CIC RANGE), BYCICVALUE(BY CIC VALUE)

BYTSRANGE(BY TS RANGE), BYTSVALUE(BY TS VALUE)

BYTSRANGE(BY TS RANGE), BYTSVALUE(BY TS VALUE)

NORMAL(Normal), FORCE(Force)
BYCICRANGE(BY CIC RANGE), BYCICVALUE(BY CIC VALUE)

None

SysOpt(System optimization), OSubcell(Overlaid subcell),


USubcell(Underlaid subcell), NoPrefer(No preference)

0~63

0~255

L0(Level0), L1(Level1), L2(Level2), L3(Level3), L4(Level4),


L5(Level5), L6(Level6), L7(Level7)

SDH, SONET
MANUAL(MANUAL), FORCED(FORCED),
CLEARALARMA(CLEARALARMA)

FORBID(Forbid), RESTORE(Restore)

0~4

0~7

One_touch(execute on all boards in all subracks), Step_by_Step

None

0~36

0~63

NO(No), YES(Yes)

500~60000

500~60000

NO(No), YES(Yes)

0~100

0~50

0~63

NO(No), YES(Yes)

1~255

1~255

0~63

0~100

TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11,
TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21,
TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31
0~335
0~15

0~31

HIGH(High), LOW(Low)

HIGH(High), LOW(Low)

HIGH(High), LOW(Low)

HIGH(High), LOW(Low)

10~2000

300~530

0_1dB(0.1dB), 0_1W(0.1W)

0~100

NO(No), YES(Yes)

0~27
0~27
0~11
NO(No), YES(Yes)

NO(No), YES(Yes)

CLOSE(Close), OPEN(Open)

1~60
0~255

10~3500

10~3500

10~3500

10~3500

10~3500

10~3500

100~10000

100~10000

1~255

400~700

50~95

50~95

50~95

50~95

NO(NO), YES(YES)

NO(Not Support), YES(Support)

10~65535

0~255

10~65535

1~8

Pan_0(0), Pan_1(1), Pan_2(2), Pan_3(3), Pan_4(4), Pan_5(5),


Pan_6(6), Pan_7(7), 255(not use)

Pan_0(0), Pan_1(1), Pan_2(2), Pan_3(3), Pan_4(4), Pan_5(5),


Pan_6(6), Pan_7(7), 255(not use)

Pan_4(4), Pan_8(8), Pan_12(12), Pan_16(16), Pan_20(20),


Pan_24(24), Pan_28(28), Pan_32(32), 255(not use)

L0(Level0), L1(Level1), L2(Level2), L3(Level3), L4(Level4),


L5(Level5), L6(Level6), L7(Level7)

0~9999

0~99
ENABLED(Enabled), DISABLED(Disabled)

0~65535

0~65535

0~255

NO(No), YES(Yes)

QoS(QoS), BE(BE), AF11(AF11), AF12(AF12), AF13(AF13),


AF21(AF21), AF22(AF22), AF23(AF23), AF31(AF31), AF32(AF32),
AF33(AF33), AF41(AF41), AF42(AF42), AF43(AF43), EF(EF)

MAINCPU_PATCH(Main programme patch), DSP_PATCH(DSP


programme patch), UCODE_PATCH(Marcrocode patch)
DB0(0dB), DB2(-2dB), DB4(-4dB), DB6(-6dB), DB8(-8dB), DB10(10dB), DB12(-12dB), DB14(-14dB), DB16(-16dB), DB18(-18dB),
DB20(-20dB), DB22(-22dB), DB24(-24dB), DB26(-26dB), DB28(28dB), DB30(-30dB)

NO(No), YES(Yes)

1~32

0~127

1~32

0~65535

1~15

BCCH(BCCH), PDCH(PDCH)
0~31

0~31
0~31
0~31

NO(NO), YES(YES)

10~160

NO(No), YES(Yes)

NO(NO), YES(YES)

10~70

1~10

0~65534

0~65534

None

None

0~2047

None

None

None
None
None

None

None

None

None

1024~65535

None

NO(No), YES(Yes)

0~255

0~63

0~255

1~48

1~60

NO(No), YES(Yes)

Disable(Disable), Enable(Enable)

Disable(Disable), Enable(Enable)

NO(No Support), YES(Support)

0~2

10~1000

10~2000

100~600000
BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33,
AF41, AF42, AF43, EF

BE(BE), AF11(AF11), AF12(AF12), AF13(AF13), AF21(AF21),


AF22(AF22), AF23(AF23), AF31(AF31), AF32(AF32), AF33(AF33),
AF41(AF41), AF42(AF42), AF43(AF43), EF(EF)

NO(No), YES(Yes)

DISABLE(Disabled), ENABLE(Enabled)

5~64

64~1024

2~1500

24~1031

NO(No), YES(Yes)

95~512
20~1500
0_level(0_level), 1_level(1_level), 2_level(2_level),
3_level(3_level), 4_level(4_level), 5_level(5_level),
6_level(6_level), 7_level(7_level), 8_level(8_level),
9_level(9_level), 10_level(10_level), 11_level(11_level),
12_level(12_level), 13_level(13_level), 14_level(14_level),
16_level(16_level), nouse(no use)

0~50

0_level(0_level), 1_level(1_level), 2_level(2_level),


3_level(3_level), 4_level(4_level), 5_level(5_level),
6_level(6_level), 7_level(7_level), 8_level(8_level),
9_level(9_level), 10_level(10_level), 11_level(11_level),
12_level(12_level), 13_level(13_level), 14_level(14_level),
16_level(16_level), nouse(no use)
0_level(0_level), 1_level(1_level), 2_level(2_level),
3_level(3_level), 4_level(4_level), 5_level(5_level),
6_level(6_level), 7_level(7_level), 8_level(8_level),
9_level(9_level), 10_level(10_level), 11_level(11_level),
12_level(12_level), 13_level(13_level), 14_level(14_level),
16_level(16_level), nouse(no use)

0~50

0_level(0_level), 1_level(1_level), 2_level(2_level),


3_level(3_level), 4_level(4_level), 5_level(5_level),
6_level(6_level), 7_level(7_level), 8_level(8_level),
9_level(9_level), 10_level(10_level), 11_level(11_level),
12_level(12_level), 13_level(13_level), 14_level(14_level),
16_level(16_level), nouse(no use)

0~50

1~100

0~1000

A(A Interface), ABIS(Abis Interface)

OFF(Off), ON(On)

0~600

30~100

30~100

1~8

2~15

CLOSE(Forced turn-off), OPEN(Forced turn-on), AUTO(Selfadaptive)

30~100

30~100

ON, OFF
0~335
0~335

0~11

0~11

0~3

1~32

0~335

0~255

0~335

0~11

0~335

0~7

0~335

0~335

0~335

0~7

0~7
0~7

0~11

0~11
0~335
0~31

0~335
0~335

0~355

0~23

0~23

0~335

0~1

0~1

0~255

250~650

6~120

6~120

NotSupport(Not Support), Support(Support)

0~9

0~9

None

None

21~65535
0~1

0~1

0~15

1~16

IP, HDLC

CLOSE(Close), OPEN(Open)

ETHER, TRUNK

TOPEXTOUTPORT(TOP Extended Out Port), TOPEXTINPORT(TOP


Extended In Port)

BCCHNorm(BCCHNorm), BCCHExt(BCCHExt)

BYBTSTYPE(By BTS Type), BYBTS(By BTS)

1~1000

CLOSE(Close), OPEN(Open)

CLOSE(Close), OPEN(Open)

CLOSE(Close), OPEN(Open)

CLOSE(Close), OPEN(Open)

CLOSE(Close), OPEN(Open)

CLOSE(Close), OPEN(Open)

0~1000

0~50

0~50

POWER_48_24(48/24 Power Module), POWER_240_24(240/24


Power Module)
220VAC(220V AC), N48VDC(-48V DC), P24VDC(+24V DC)

0~13

80W(80W), 63W(63W), 60W(60W), 55W(55W), 50W(50W),


45W(45W), 40W(40W), 31W(31W), 30W(30W), 27W(27W),
26W(26W), 25W(25W), 24W(24W), 21W(21W), 20W(20W),
19W(19W), 18W(18W), 17W(17W), 16W(16W), 15W(15W),
14W(14W), 13_3W(13.3W), 13W(13W), 12_5W(12.5W),
12W(12W), 11_5W(11.5W), 11W(11W), 10W(10W), 9_5W(9.5W),
9W(9W), 8_5W(8.5W), 8W(8W), 7_5W(7.5W), 7W(7W),
6_5W(6.5W), 6W(6W), 5_5W(5.5W), 5W(5W), 4_5W(4.5W),
4W(4W), 3_7W(3.7W), 3_1W(3.1W), 3W(3W), 2_5W(2.5W),
2W(2W), 200mW(200mW), DEFAULT(Default)

0~100

0~100

0~15

0~499
0~499

0~499

Disable(Disable), Enable(Enable)

0~5

NO(No), YES(Yes)

NOT_ALLOWED(Not Allowed), ALLOWED(Allowed)

OFF(Off), ON(On)

1~255

0~255

0(No packet access), 3(Packet access of level 1), 4(Packet access


of levels 1-2), 5(Packet access of levels 1-3), 6(Packet access of
level 1-4)

NO(No), YES(Yes)

NO(No), YES(Yes)

30~100

30~100

30~100

30~100

ON, OFF

PRIOR-1(Priority-1), PRIOR-2(Priority-2), PRIOR-3(Priority-3),


PRIOR-4(Priority-4), PRIOR-5(Priority-5), PRIOR-6(Priority-6),
PRIOR-7(Priority-7), PRIOR-8(Priority-8), PRIOR-9(Priority-9),
PRIOR-10(Priority-10), PRIOR-11(Priority-11), PRIOR-12(Priority12), PRIOR-13(Priority-13), PRIOR-14(Priority-14), PRIOR15(Priority-15), PRIOR-16(Priority-16)

Prior-1, Prior-2, Prior-3, Prior-4, Prior-5, Prior-6, Prior-7, Prior-8,


Prior-9, Prior-10, Prior-11, Prior-12, Prior-13, Prior-14, Prior-15,
Prior-16
0~100

0(0), 1(1), 2(2), 3(3), 4(4), 5(5), 6(6), 7(7), nouse(no use)

0~99

0~99

HIGH, LOW

TDME1_O(TDM E1 0 Port), TDME1_1(TDM E1 1 Port), FE_E(FE


Electric Port), FE_O(FE Optical Port), IPOE(IP over E1)
1(1), 2(2)
TDME1_O(TDM E1 0 Port), TDME1_1(TDM E1 1 Port), FE_E(FE
Electric Port), FE_O(FE Optical Port), IPOE(IP over E1)
None
DEFAULT(Default Sequence), CUSTOMIZDE(Customized
Sequence), DISABLE(DISABLE)

ITUT(ITUT), ANSI(ANSI), TTC(TTC)

Q933(Q933), ANSI(Ansi)

5~300

0~255

60~3600

ALL(Select all ports), SINGLE(Select one port)


ALL(Select all ports), SINGLE(Select one port)

ALL(Select all E1/T1 ports), PORT(Select all E1/T1 ports of one


channelized optical port), SINGLE(Select one E1/T1 port)
OFF(Not Output), ON(Output)

OFF(Not Output), ON(Output)

OFF(Not Output), ON(Output)

OFF(Not Output), ON(Output)

OFF(Not Output), ON(Output)

0~100

0~100

NO(No Support), YES(Support)

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33,
AF41, AF42, AF43, EF

0~7

0~7

1~16

NO(No), YES(Yes)

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33,
AF41, AF42, AF43, EF

0~7

0~7

0~63

COMMONUSRM(Common User Mode), SPECUSRM(Specified User


Mode)

-121~-104

-121~-104

OFF(OFF), ON(ON)

10~10000

100~600000

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

0~63

NO(NO), YES(YES)

ON(ON), OFF(OFF)

0~31

BOOL(BOOL), VALUE(VALUE)

BOOL(BOOL), VALUE(VALUE)
GB_OVER_FR(Gb over FR), GB_OVER_IP(Gb over IP)

123~65534

B8ZS(B8ZS), HDB3(HDB3), AMI(AMI), AMI_ZCS(AMI_ZCS)

E1_DOUBLE_FRAME(E1_DOUBLE_FRAME),
E1_CRC4_MULTI_FRAME(E1_CRC4_MULTI_FRAME),
T1_SUPER_FRAME(T1_SUPER_FRAME),
T1_EXTENDED_SUPER_FRAME(T1_EXTENDED_SUPER_FRAME)
E1_DOUBLE_FRAME(E1_DOUBLE_FRAME),
E1_CRC4_MULTI_FRAME(E1_CRC4_MULTI_FRAME),
T1_SUPER_FRAME(T1_SUPER_FRAME),
T1_EXTENDED_SUPER_FRAME(T1_EXTENDED_SUPER_FRAME)
E1_DOUBLE_FRAME(E1_DOUBLE_FRAME),
E1_CRC4_MULTI_FRAME(E1_CRC4_MULTI_FRAME),
T1_SUPER_FRAME(T1_SUPER_FRAME),
T1_EXTENDED_SUPER_FRAME(T1_EXTENDED_SUPER_FRAME)

0~15

FE, GE
APM100(APM100), APM200(APM200), APM30(APM30),
EPS4890(EPS4890), EPS4815(EPS4815), SC48200~5||
(SC48200)$$(SC48200)** CUSTOM(SC48200)** CUSTOM~100||
()$$(CUSTOM)
None

None

None

1~65535

None

None

None

6~32

0~31
BIT0, BIT1, BIT6, BIT7, BIT8, BIT9, BIT14, BIT15, BIT16, BIT17,
BIT22, BIT23, BIT24, BIT25, BIT29, BIT30, BIT31
BIT0, BIT1, BIT2, BIT3, BIT4, BIT5, BIT6, BIT7, BIT8, BIT9, BIT10,
BIT11, BIT12

NO(No), YES(Yes)

NO(No), YES(Yes)

PWR2(Power control II), PWR3(Power controlIII)

0~3

NO(No), YES(Yes)

OnlyCurPwrLoc(Only Current Working Location TRXes be Turned


On), ALLPwrLoc(All Location TRXes be Turned On)

CLASS0(Class0), CLASS1(Class1), CLASS2(Class2)

0~720

NO(No), YES(Yes)

DB0(0.0dB), DB2(-0.2dB), DB4(-0.4dB), DB6(-0.6dB), DB8(0.8dB), DB10(-1.0dB), DB12(-1.2dB), DB14(-1.4dB), DB16(1.6dB), DB18(-1.8dB), Default(Default)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

0~63

0~63

0~63

0~63

0~63

Use_Qsearch_I(Use Qsearch_I), Always(Always)

NO(No), YES(Yes)

1~10

0~255

1~10

0~15

1~32

1~32

NO(Not Support), YES(Support)

0~15

0~15

NO(Close), YES(Open)

1~16

1~16

NONE(None), DYNAMIC(Dynamic power sharing)

3~20

3~20

0~4

NO(No), YES(Yes)

NO(No), YES(Yes)

AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7

NO(No), YES(Yes)
INSIDE_100AH(100AH Inside Storage Battery),
INSIDE_50AH(50AH Inside Storage Battery),
OUTSIDE_300AH(300AH Outside Storage Battery),
OUTSIDE_400AH(400AH Outside Storage Battery),
OUTSIDE_500AH(500AH Outside Storage Battery),
OUTSIDE_650AH(650AH Outside Storage Battery),
OUTSIDE_200AH(200AH Outside Storage Battery)

007C(0.07C), 010C(0.10C), 015C(0.15C)

INSIDE_BATTERY(Inside Storage Battery),


OUTSIDE_BATTERY(Outside Storage Battery)

AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7

NO(No), YES(Yes)
INSIDE_100AH(100AH Inside Storage Battery),
INSIDE_50AH(50AH Inside Storage Battery),
OUTSIDE_300AH(300AH Outside Storage Battery),
OUTSIDE_400AH(400AH Outside Storage Battery),
OUTSIDE_500AH(500AH Outside Storage Battery),
OUTSIDE_650AH(650AH Outside Storage Battery),
OUTSIDE_200AH(200AH Outside Storage Battery)

007C(0.07C), 010C(0.10C), 015C(0.15C)

INSIDE_BATTERY(Inside Storage Battery),


OUTSIDE_BATTERY(Outside Storage Battery)

AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7

NO(No), YES(Yes)
INSIDE_100AH(100AH Inside Storage Battery),
INSIDE_50AH(50AH Inside Storage Battery),
OUTSIDE_300AH(300AH Outside Storage Battery),
OUTSIDE_400AH(400AH Outside Storage Battery),
OUTSIDE_500AH(500AH Outside Storage Battery),
OUTSIDE_650AH(650AH Outside Storage Battery),
OUTSIDE_200AH(200AH Outside Storage Battery)

007C(0.07C), 010C(0.10C), 015C(0.15C)

INSIDE_BATTERY(Inside Storage Battery),


OUTSIDE_BATTERY(Outside Storage Battery)
0~255

0~255

0~255

0~255

0~255

0~255

-121~-104

0~63

0~65535

-121~-104

0~7

NO(No), YES(Yes)

0~255

0dB(0dB), 2dB(2dB), 4dB(4dB), 6dB(6dB), 8dB(8dB),


10dB(10dB), 12dB(12dB), 14dB(14dB), nouse(no use)

10M(10M), 100M(100M), AUTO(Auto)

ALG1(Algorithm I), ALG2(Algorithm II), NONE(None)

DISABLE(Disable), ENABLE(Enable)

1~255

LASTRBP(last rollbackpoint), APPOINTRBP(appointed


rollbackpoint)

REC_ALL(Record All), REC_ERR(Record Errors), REC_NON(Record


None)

0~249

0~249

0~249

INDEPENDENT(Independent Receiver), DIVIDING(Dividing


Receiver), FOURDIVERSITY(Four Diversity Receiver),
MAINDIVERSITY(Main Diversity), NONE(None)

0~100

NO(No), YES(Yes)

Same_Band(Same Band), Diff_Band(Different Band)

0~70

0~70

0~63

0~63

NO(No), YES(Yes)

NO(No), YES(Yes)

20~99

0~70

NO(No), YES(Yes)

YES(YES), NO(NO)

0~50

0~768

0~31

0~31

0~31

0~31

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

NO(NO), YES(YES)

0~95

hour, min, sec

1~3600
REHOSTRIGHTNOW(ReHostRightNow),
REHOSTDELAY(ReHostDelay), REHOSTWHEN(ReHostWhen)
NO(NO), YES(YES)

0~62

NO(NO), YES(YES)

OFF(OFF), POWERSHARING(Power Sharing Between Boards),


RF_FH(RF Frequency Hopping Between Boards)
0~23

0~255

A(A), B(B), NONE(NONE)

None

None

0~1023

0~65535

NO(No), YES(Yes)

0~7

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

0~63

1~10

1~32

1~32

0~8

0~16

NO(No), YES(Yes)

0~65535

1~60

1~255

1~15

1~120
MSLOST(RADIO_STS_MS_LOST),
QUALITYBAD(RADIO_STS_QUALITY_BAD),
CELLRESELECT(RADIO_STS_CELL_RESELECT)
NO(No), YES(Yes)

NO(No), YES(Yes)

2~5

2~5
Noneed, Manually, Reset, Normally, Correlative, Configuration,
Expired

0~86400

0~190

0~21

0~255

1~100

NO(No), YES(Yes)

RGPS(RGPS), GPS(GPS)

NO(No Support), YES(Support)


TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times,


28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times,
52_Times, 56_Times, 60_Times, 64_Times

STANDALONETC(Stand Alone TC ), MASTERINPOOLTC(Master in


Pool TC), SLAVEINPOOLTC(Slave in Pool TC)

0~4095

0~16,255

0~16

None

None

1~100

1~100

DISABLE(Disable), ENABLE(Enable), UNSUPPORT(Unsupport)


0.48sec(0.48sec), 0.96sec(0.96sec), 1.92sec(1.92sec),
3.84sec(3.84sec), 7.68sec(7.68sec), 15.36sec(15.36sec),
30.72sec(30.72sec), 61.44sec(61.44sec)
0.48sec(0.48sec), 0.96sec(0.96sec), 1.92sec(1.92sec),
3.84sec(3.84sec), 7.68sec(7.68sec), 15.36sec(15.36sec),
30.72sec(30.72sec), 61.44sec(61.44sec)
20~99

NO(Not report), YES(Report), NONE(None)

0~31

0~31

0~2047

SHARE, EXCLUSIVE
SHARE(SHARE)

0~255

0~63

0~63

BASIS_OF_B1, BASIS_OF_B2

BASIS_OF_B1, BASIS_OF_B2

MINUS_52db(-52db), MINUS_48db(-48db), MINUS_44db(-44db),


MINUS_40db(-40db), MINUS_36db(-36db), MINUS_32db(-32db),
MINUS_28db(-28db), MINUS_24db(-24db), MINUS_20db(-20db),
MINUS_16db(-16db), MINUS_12db(-12db), MINUS_10db(-10db),
MINUS_8db(-8db), MINUS_6db(-6db), MINUS_4db(-4db),
MINUS_2db(-2db), Zerodb(0db), 2db(2db), 4db(4db), 6db(6db),
8db(8db), 10db(10db), 12db(12db), 16db(16db), 20db(20db),
24db(24db), 28db(28db), 32db(32db), 36db(36db), 40db(40db),
44db(44db), 48db(48db), nouse(no use)

0~64

0~63

0~7

0~64

2~4094

0~96
COMMISSIONING(Commissioning), UPGRADE(Upgrade),
RESTORE(Restore)

0~127

None

None

OFF(OFF), ON(ON)

1~65535

0~190

OFF(OFF), ON(ON)

0~4294967295

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

0~4294967295

0~4294967295

0~4294967295

0~3

NON-REVERTIVE(NON-REVERTIVE), REVERTIVE(REVERTIVE)

0~4294967295

1~5

OFF(Close), ON(Open)

None

None

0~15

0~100

0~100

500~60000

500~60000

500~60000

DISABLE(Disable), ENABLE(Enable)

10~80

NEXTHOP(Next Hop), OUTIF(Out Interface)

0~1000

1~100

0~999

1~3000000

0~4000000

0~63

0~70

0~63

NO(No), YES(Yes)

0~70

0~70

0~70

0~70

0~70

0~70

0~70

0~70

0~70

0~70

0~70

0~70

0~249

0~249

0~249

RXUNAME(By RXU Name), RXUPOS(By RXU Position No),


SRNSN(By Subrack No)
RXUNAME(RXUName), RXUPOS(RXUPOS), SRNSN(SRNSN)

None

None

None

1~6

1~6

1~6
DRRU(DRRU), DRFU(DRFU), MRRU(MRRU), MRFU(MRFU),
GRFU(GRFU), GRRU(GRRU), BTS3900E(BTS3900E)
OFF(OFF), ON(ON)

0~15

48VDISABLE, RES0, RES1, RES2, TSDISABLED, HSDISABLED,


RES3, RES4

BT1_DISABLE, AH_DISABLE, AT1_DISABLE, AT2_DISABLE,


BT2_DISABLE

NO(No), YES(Yes)

NO(No), YES(Yes)

0~2

0~4

T1_DISABLE, ET_DISABLE, ET1_DISABLE, ET2_DISABLE,


T2_DISABLE

0~2047

BYNAME(By name), BYID(By index)

1~16

0~100

None

0~63

WATER_IMMERSED, SMOG, GM_DISABLE

WIDISABLE, SMDISABLE, IMDISABLE, GMDISABLE

WILOW, SMLOW, IMLOW, GMLOW

NO(NO), YES(YES)

WS_DISABLE, SS_DISABLE, GS_DISABLE

0~2047

None

ADD0dB(+0dB), ADD10dB(+10dB), Automatic(Automatic)

0~63

1~20

0~2047

None

GERMAN(GERMAN), ENGLISH(ENGLISH), ITALIAN(ITALIAN),


FRENCH(FRENCH), SPANISH(SPANISH), DUTCH(DUTCH),
SWEDISH(SWEDISH), DANISH(DANISH),
PORTUGUESE(PORTUGUESE), FINNISH(FINNISH),
NORWEGIAN(NORWEGIAN), GREEK(GREEK), TURKISH(TURKISH),
HUNGARIAN(HUNGARIAN), POLISH(POLISH), GB2312(GB2312),
KOI8-R(Cyrillic KOI8-R), KOI8-U(Cyrillic KOI8-U), KOI8(Cyrillic
KOI8), WINDOWS-1251(Cyrillic Windows), ASMO_449(Arabic
ASMO), WINDOWS-1256(Arabic Windows), WINDOWS-874(Thai
Windows), WINDOWS-1253(Greek Windows), WINDOWS1254(Turkish Windows), WINDOWS-1255(Hebrew Windows),
WINDOWS-1257(Baltic Windows), WINDOWS-1250(Eastern
European Windows), WINDOWS-1252(Western European
Windows), BINARY(BINARY), UCS2(UCS2), RCS-1(Reserved Code
Scheme 1), RCS-2(Reserved Code Scheme 2), RCS-3(Reserved
Code Scheme 3), RCS-4(Reserved Code Scheme 4), RCS5(Reserved Code Scheme 5)

0~1

None

BYBTSID(By BTS ID), BYCELLID(By Cell ID)

0~23

0~511

1~2147483646

0~1199

year, month, day

year, month, day

7~90

year, month, date

1E-3, 1E-4, 1E-5, 1E-6, 1E-7, 1E-8, 1E-9

year, month, day

1~31

1~191

OFF(Off), ON(On)

0~100

0~63

0~70

0~63

0~70

NO(No), YES(Yes)

DISABLE, ENABLE

OFF(Off), ON(On)

DISABLE(Disable), ENABLE(Enable)

0~60

0~5

0~255

0~63

0~63
HIGH(HIGH), LOW(LOW)

40~70

0~65535

0~65535

350~556

NO(No), YES(Yes)

None

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NoPriority(No Priority), Priority4(Priority 4), Priority3(Priority3),


Priority2(Priority 2), Priority1(Priority 1), Priority0(Priority 0),
PriorityB(Priority B), PriorityA(Priority A)

NoPriority(No Priority), Priority4(Priority 4), Priority3(Priority3),


Priority2(Priority 2), Priority1(Priority 1), Priority0(Priority 0),
PriorityB(Priority B), PriorityA(Priority A)

NO(NO), YES(YES)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

0~6

SUPPORT(Support), UNSUPPORT(Not Support)

1024~65535

1024~65535

None

None

SEPARATE(Separate), TOGETHER(Together), AIP(AIP)

TDM, HDLC, HDLC_HubBTS, IP

TDM, HDLC, IP

SYSTEM(System Command), CONFIG(Configuration


Management), MAINTAIN(Maintenance Management),
STAT(Statistic Measurement), ALARM(Alarm Management)
OML(OML), RSL(RSL), EML(EML), ESL(ESL), CSVOICE(CS Voice),
CSDATA(CS Data), PSHIGHPRI(PS High PRI), PSLOWPRI(PS Low
PRI), OTHERDATA(Other Data)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

0~5

0~65535
None
1~10

0~1023

NO(No), YES(Yes)

0( Release 98 or older), 1(Release 99 onwards)

UNISTALL(Uninstall), ALLOW(Allow), DENY(Deny)

50~95

0~27

NO(NO), YES(YES)

unshielded(Unshielded), shielded(Shielded)

0~12

NO(No), YES(Yes)

NO(No), YES(Yes)

1~10

0~186

0~186
0~15

0~255

0~255

0~7

1~10

1~31

0~15

1~31

0~65535

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
0~65535

0~255

None

0~35

E1SELFLOOP(E1 Self Loopback), IASUSELFLOOP(IASU Self


Loopback)

B0000(B0000),
B0100(B0100),
B1000(B1000),
B1100(B1100),

1~600

B0001(B0001),
B0101(B0101),
B1001(B1001),
B1101(B1101),

B0010(B0010),
B0110(B0110),
B1010(B1010),
B1110(B1110),

B0011(B0011),
B0111(B0111),
B1011(B1011),
B1111(B1111)

DATE(Input with date), WEEK(Input with week), DATEWEEK(Input


with date and week)

0~3

NOTSUPPORT(Not Support), INNER(Inner), OUTER(Outer)

CLOSE(Close), OPEN(Open)
JAN(January), FEB(February), MAR(March), APR(April), MAY(May),
JUN(June), JUL(July), AUG(August), SEP(September),
OCT(October), NOV(November), DEC(December)

2~2000

0,2,4,8,10,12,14,16,18,20,22,24,26

0~27

0~3,8~27

0~27

0,2,4,8,10,12,14,16,18,20,22,24,26
0~27

0~27

0~23

0~27

0,2,4,8,10,12,14,16,18,20,22,24,26

0~5,8~27

0~5,8~27

0~5,8~27

0,2,4,8,10,12,14,16,18,20,22,24,26

0~27
0~27

0~23

0~23

0~27

0~7

NOCOMB(No Combination), PBT(PBT), WBANDCOMB(Wideband


Combination), DIVERSITY(Transmit Diversity),
DDIVERSITY(Dynamic Transmit Diversity), DPBT(DPBT),
DTIC(Transmit Independency or Combination), NONE(none)

SGL_ANTENNA(Single Feeder[1TX + 1RX]),


SGLDOUBLE_ANTENNA(Single Feeder[1TX + 2RX]),
DOUBLE_ANTENNA(Double Feeder[2TX + 2RX]),
DOUBLEFOUR_ANTENNA(Double Feeder[2TX + 4RX]),
DOUBLESINGLE_ANTENNA(Double Feeder[1TX + 1RX]),
DOUBLEDOUBLE_ANTENNA(Double Feeder[1TX + 2RX])

SGL_ANTENNA(Single Feeder[1TX + 1RX]),


SGLDOUBLE_ANTENNA(Single Feeder[1TX + 2RX]),
DOUBLE_ANTENNA(Double Feeder[2TX + 2RX]),
DOUBLEFOUR_ANTENNA(Double Feeder[2TX + 4RX]),
DOUBLESINGLE_ANTENNA(Double Feeder[1TX + 1RX]),
DOUBLEDOUBLE_ANTENNA(Double Feeder[1TX + 2RX])
SGL_ANTENNA(Single Feeder[1TX + 1RX]),
SGLDOUBLE_ANTENNA(Single Feeder[1TX + 2RX]),
DOUBLE_ANTENNA(Double Feeder[2TX + 2RX]),
DOUBLEFOUR_ANTENNA(Double Feeder[2TX + 4RX]),
DOUBLESINGLE_ANTENNA(Double Feeder[1TX + 1RX]),
DOUBLEDOUBLE_ANTENNA(Double Feeder[1TX + 2RX])
SGL_ANTENNA(Single Feeder[1TX + 1RX]),
SGLDOUBLE_ANTENNA(Single Feeder[1TX + 2RX]),
DOUBLE_ANTENNA(Double Feeder[2TX + 2RX]),
DOUBLEFOUR_ANTENNA(Double Feeder[2TX + 4RX]),
DOUBLESINGLE_ANTENNA(Double Feeder[1TX + 1RX]),
DOUBLEDOUBLE_ANTENNA(Double Feeder[1TX + 2RX])
SGL_ANTENNA(Single Feeder[1TX + 1RX]),
DOUBLESINGLE_ANTENNA(Double Feeder[1TX + 1RX]),
DOUBLEDOUBLE_ANTENNA(Double Feeder[1TX + 2RX])
1~60

1~16777215

BIT14(BIT14), BIT16(BIT16), BIT24(BIT24)

None
0~65535

WNF(Whole Number Format), DNF(Divided Number Format)

L11_FORBID, L12_FORBID, L13_FORBID, L14_FORBID,


L15_FORBID

ET_DISABLE0, ET_DISABLE1, SMDISABLE, WIDISABLE,


GMDISABLE, ARRESTER1, ARRESTER2

SMDISABLE, WIDISABLE, GMDISABLE, ARRESTER1, ARRESTER2

1~12

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

PSMODE(Protocol Standard Mode), VGCSMODE(VGCS Mode)

PSMODE(Protocol Standard Mode), VGCSMODE(VGCS Mode)

FR(FR), EFR(EFR)

1000M(1000M), AUTO(AUTO)

0~63

0~255

NO(NO), YES(YES)

NOTSPPRTBC(NotSupport CB), SPPRTSTANDARD(SupportStandard


CB), SPPRTSIMPLE(SupportSimple CB)

NO(No Support), YES(Support)

NO(No Support), YES(Support)

UNSUPPORT(Not Support), SUPPORT(Support)

UNSUPPORT(Not Support), SUPPORT(Support)

NO(NO), YES(YES)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

NO(No), YES(Yes)

UNSUPPORT(Not Support), SUPPORT(Support)

NO(NO), YES(YES)

YES(Support), NO(Not Support)

0~4

SUPPORT(Support), NOT_SUPPORT(Not Support)

SUPPORT(Support), NOT_SUPPORT(Not Support)

SUPPORT~1||(SRAN)$$(Support SRAN)**
NOT_SUPPORT(Support SRAN)** NOT_SUPPORT~0||()$$(Not
Support)

0~2047

None

0~2047

None

0~65535

None

1~4

1~4

HOALGORITHM1(Handover algorithm I),


HOALGORITHM2(Handover algorithm II)
None
1~65533,65535

None
1~1000
None
0~335

BITS1-2MHZ(2MHZ Building Integrated Timing Supply system 1),


BITS2-2MHZ(2MHZ Building Integrated Timing Supply system 2),
BITS1-2MBPS(2MBPS Building Integrated Timing Supply system
1), BITS2-2MBPS(2MBPS Building Integrated Timing Supply
system 2), 8KHZ(8KHZ), GPS(Globe Positioning System),
LINE1_8KHZ(8KHZ line1), LINE2_8KHZ(8KHZ line2), BITS1T1BPS(T1BPS Building Integrated Timing Supply system 1),
BITS2-T1BPS(T1BPS Building Integrated Timing Supply system 2)

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31
0~11

0~11

1~11

0~11

0~11

0~11

0~254

0~11

0~11

0~11

0~11

0~11

0~11

0~11

0~254

0~254

0~11

0~11

0~11

None

0~5

MPS, EPS, TCS

DES(Descent), ASC(Ascent)

0~255

0~255

GSM_PRIOR(GSM Traffic Prior), UMTS_PRIOR(UMTS Traffic Prior)


CSVOICE(CS Voice), CSDATA(CS Data), PSHIGHPRI(PS High PRI),
PSLOWPRI(PS Low PRI)

0~63

20~99

30~100

20~99

30~100

1~32

1~32

0~7

0~7

1~2147483646

0~63

hour, min, sec

hour, min, sec

year, month, date, hour, min, sec

hour, min

year, month, date, hour, min, sec

year, month, day, hour, min, sec

HOUR, MIN, SEC

1~65535

NO(No), YES(Yes)

NO(No), YES(Yes)

0~65535

0~65535

1~31

-990~400

JAN(Jan.), FEB(Feb.), MAR(Mar.), APR(Apr.), MAY(May), JUN(Jun.),


JUL(Jul.), AUG(Aug.), SEP(Sep), OCT(Oct.), NOV(Nov.), DEC(Dec)

NO(No), YES(Yes)

NO(No), YES(Yes)

0(0), 2(2), 4(4), 6(6)

60~600

hour, min

1~31

8~255

1~31

DISABLED(Disabled), ENABLED(Enabled)

DISABLED(Disabled), ENABLED(Enabled)

0~65535

0~62

year, month, day

1~32

NO(NO), YES(YES)
hour, min, sec

NO(No), YES(Yes)

OFF(Off), ON(On)

60~300
OFF(OFF), ON(ON)
0~23

hour, min, sec

0~23

0~254

0~7

hour, min, sec

1~31

BTS30(BTS30), BTS312(BTS312), BTS3001C(BTS3001C),


BTS3001CP(BTS3001CP), BTS3002C(BTS3002C),
BTS3012A(BTS3012A), BTS3006A(BTS3006A),
BTS3012(BTS3012), BTS3006C(BTS3006C),
BTS3002E(BTS3002E), BTS3012AE(BTS3012AE),
BTS3012_II(BTS3012 II), DBS3900_GSM(DBS3900 GSM),
BTS3900_GSM(BTS3900 GSM), BTS3900A_GSM(BTS3900A GSM),
DBS3036(DBS3036), BTS3036(BTS3036), BTS3036A(BTS3036A),
BTS3900L_GSM(BTS3900L GSM), BTS3900B_GSM(BTS3900B
GSM), BTS3900E_GSM(BTS3900E GSM)

1~15

1~15

None

16~1023

16~1023

1~50

1~124,128~189

NO(No), YES(Yes)

NO(NO), YES(YES)

0(0), 2(2), 4(4), 6(6)

0~65535

NO(No), YES(Yes)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(No), YES(Yes)

NOTSUPPORT(Not Support), SUPPORT(Support)

UNSUPPORT(Not Support), SUPPORT(Support)

NOTSUPPORT(Not Support), SUPPORT(Support)

UNSUPPORT(Not Support), SUPPORT(Support)

NO(No), YES(Yes)

NO(Not Support), YES(Support)

NO(No Support), YES(Support)

T_12(12), T_15(15), T_20(20), T_30(30), T_41(41), T_55(55),


T_76(76), T_109(109), T_163(163), T_217(217)

None

0~65535

CLOSE(CLOSE), OPEN(OPEN)

ON, OFF

OFF(OFF), ON(ON)

CLOSE(Close), OPEN(Open)

ON(ON), OFF(OFF)
SUN(Sunday), MON(Monday), TUE(Tuesday), WED(Wednesday),
THU(Thursday), FRI(Friday), SAT(Saturday)
CLOSE, OPEN

BFD_OFF(OFF), BFD_ON(ON)

ON(ON), OFF(OFF)

ON(ON), OFF(OFF)

NO(NO), YES(YES)

CLOSE(Close), OPEN(Open)

NO(NO), YES(YES)

1~254

OFF(OFF), ON(ON)

0~4294967295

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

OFF(OFF), ON(ON)

0~4294967295

0~4294967295

0~4294967295

3~5

OFF(Off), ON(On)
FIRST(First), SECOND(Second), THIRD(Third), FOURTH(Fourth),
LAST(Last)

0~2500

SyncCase1(Sync case 1), SyncCase2(Sync case 2)

AISS(Air Interface Software Sync), GPS(GPS Synchronization)


CONSYN(Consecutive Synchronizing), INTERSYN(Intermittent
Synchronizing)
1~7

0~23

0~59

None

None

0,8~11

None

NO(No), YES(Yes)

None

None

1~60

1000~30000

30000~60000

800~1500

800~1500

2000~3000

800~1500

800~1200

1~60

1000~120000

6~240

1~255

1~255

1~255

1~255

1~255

1~255

1~255

1~10

180000~360000

180000~360000

1400~2000

1~60

1000~10000

0~255

1~255

500ms(500ms), 1000ms(1000ms), 1500ms(1500ms),


2000ms(2000ms), 2500ms(2500ms), 3000ms(3000ms),
3500ms(3500ms), 4000ms(4000ms)

0ms(0ms), 80ms(80ms), 120ms(120ms), 160ms(160ms),


200ms(200ms), 500ms(500ms), 1000ms(1000ms),
1500ms(1500ms)

0~255

5~30

800~1200

1000~10000

800~1200

1000~30000

800~1200

1000~10000

1000~10000

800~1200

1~31

NO(No), YES(Yes)

NO(No), YES(Yes)

0~255

1~16

0~255

0~255

1~31

0~7

1~16

0~255

0~25

0~25

1~12

1~12

30~300

60~300

1~254

1000~10000

0~500

OFF(Off), ON(On)

NO(No), YES(Yes)

0~100

0~1000

0~63

0~70

0~1000

0~63

0~70

0~60

0~10

NO(No), YES(Yes)

1~600

OFF(Off), ON(On)

0~100

0~100

1~15

SEPERATE_PRINCIPAL(Principal BSC),
SEPERATE_SUBORDINATE(Subordinate BSC), TOGETHER(BSC/TC
Together), SEPERATE_BSC_INTERFACE(BSC Interface)

DISABLE(DISABLE), ENABLE(ENABLE)

0~62

0~335

0~4095

0~5,8~27

0~11

GTC(GTC), UTC(UTC), ITC(ITC)

AUTO(Auto), Manual(Manual)

AUTO(Auto), Manual(Manual)

0~7

0~15

0~7

0~1

0~16383

NO(No), YES(Yes)

NO(No), YES(Yes)

0~63

0~127

0~127

NO(No), YES(Yes)

0~1

0~100
0~100
0~5

0~5

0~127

CLOSE(Close), OPEN(Open)

None

None

-500~1000

-490~1000

-500~1000

-500~990

0~5000

None

1~65535

32768~65535

None

50~70

-400~0

-400~0

NO(No), YES(Yes)

1~255

None

OFF(Off), ON(On)

0~1023

0~65535

ACTIVE(Active OMU), STANDBY(Standby OMU)

0~255

None

None

0~5,8~27

0~11

5000~60000

220~280

220~280

1~10

1~10

1~10

1~10

1~10

1~10

1~10

1~10

1~10
PERCENTAGE(Percentage), BANDWIDTH(Band Width)
1~15

0~63

0~7

1~32

0~100

1~32

0~7

OFF(Off), ON(On)

0~63

3~15

0,5~1440

HOUR, MIN, SEC

NOLIMIT(No Limit), LIMIT(Limit)

0~255

0~255

0~255

1~20

200~10000
1~65535
1~3
1~10

0~255

1~1024

NO(No), YES(Yes), NULL(Null)

0~255

10~255

1~30

1~15

7~365

0~4294967295

-99~70

-19~5

-99~99

hour, min

hour, min

hour, min

hour, min

hour, min

hour, min
14~163
0~163

1~120

NON_FDR(NON_FDR), FDR(FDR)

2~4

0~100

0~4294967294

0~100

8000~12000

30000~90000
PRACHTFCSGAINFACTORREFTFCNUM,
PRACHTFCSSIGNALLEDGAINFACTOR, PSCH, PSDOMAINSYSINFO,
QOSACTPARAS, QUEUREEMPTALGOPARA, RACH,
RACHINTRAFREQRPTQUANTITY, RACHTFSDYNPART,
RACHTFSTBNUMBER, RATCELLBASICINFO, RATQOFFSET1SN,
RATQRXLEVMIN, RNC10NRNCURA, RNC11NRNCURA,
RNC12NRNCURA, RNC13NRNCURA, RNC14NRNCURA,
RNC15NRNCURA, RNC1NRNCURA, RNC2NRNCURA,
RNC3NRNCURA, RNC4NRNCURA, RNC5NRNCURA,
RNC6NRNCURA, RNC7NRNCURA, RNC8NRNCURA,
RNC9NRNCURA, RNCAMRCPARAS, RNCAMRCWBPARAS,
RNCBASICINFO, RNCCBCPUID, RNCCBPARA, RNCCMCFPARAS,
RNCCOUNTERCHKPARA, RNCCTRLSHAREPARA, RNCDCCCPARAS,
RNCDPBPARAS, RNCDRDPARAS, RNCFPDCHRLPWRPARA,
RNCHCSHOPARAS, RNCHOCOMMAPB, RNCHONCOVALGPRIOAPB,
RNCHSDPCCHPOPARAS, RNCINTERFREQHOCOVAPB,
RNCINTERFREQHONCOVAPB, RNCINTERRATHOCOVAPB,
RNCINTERRATHONCOVAPB, RNCINTRAFREQHOAPB,
RNCLDMPARAS, RNCMBMSALARMSERVICE, RNCMBMSCFGPARA,
RNCMBMSFACH, RNCMBMSINACTTMR, RNCOLPCPARAS,
RNCPSINACTTIMER, RNCQOSHOAPB, RNCQUALITYMEASPARAS,
RNCREFTIMEAPB, RNCSECURITYINFO, RNCTGPSCP,
RNCUSERPLANSHAREPARA, ROUTEAREAINFO, RRALGOSWITCH,
RRCESTCAUSE, RRINNERTIMER, RRMCDLCFG, RRSTATETIMER,
RRTIMERRESERVED, RRTSTSWITCH, SAMBMSCFGPARA, SCCPCH,
SCCPCHNOSPLITTFCS0, SCCPCHNOSPLITTFCS1,
SCCPCHNOSPLITTFCS2, SCCPCHNOSPLITTFCS3,
SCCPCHNOSPLITTFCS4, SCCPCHPILOTSYMBOLEXIST,
SCCPCHSCRAMBCODE, SCCPCHTFCIPRESENCE,
SCHEDULEPRIOMAPINFO, SEG0CELLURA, SEG0GSMNCELL,
SEG0INTERFREQNCELL, SEG0INTRAFREQNCELL, SEG10CELLURA,
SEG10GSMNCELL, SEG10INTERFREQNCELL,

TRRS(Terrestrial Transmission), SATEL(Satellite Transmission)

TRRS(Terrestrial Transmission), SATEL(Satellite Transmission)

0~7

-120~-1,1~120

0~62

0~23

0~254

NORMAL(TXT FORMAT), FORMAT(BIN FORMAT)

0~5

1~30

30~100

30~100

30~100

30~100

ON, OFF

1~255

1~255

M3UA_OVERRIDE_MOD(Active/Standby Mode),
M3UA_LOADSHARE_MOD(Load Sharing Mode)

TER_TRANS(Terrestrial Transmission), SAT_TRANS(Satellite


Transmission), TER_AND_SAT_TRANS(Terrestrial and Satellite)

0~27
IP(IP)

IP(IP), HDLC(HDLC)

IP(IP), HDLC(HDLC), TDM(TDM)

HDLC, IP

IP, HDLC, TDM

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

NO(NO), YES(YES)

ENABLE(Enable Trace Range Limit), DISABLE(Disable Trace Range


Limit)
5sec(5sec), 10sec(10sec), 15sec(15sec), 20sec(20sec),
30sec(30sec), 60sec(60sec), 120sec(120sec), 300sec(300sec),
nouse(no use)
0~100
0~11
0~5,8~27

0~11

0~163
0~199
0~199

0~199
0~199
0~199

10~199

0~199

OFF(OFF), ON(ON)
0~11
0~11
0~11

TRXAid_NotAllow(TRX Aiding Not Allowed),


AllowReForbid(Allowed & Recover Forbidden),
AllowReImmed(Allowed & Recover Immediately),
AllowReCheckRes(Allowed & Recover When Chk Res)

5~10

0~63,255

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

0~3071

None

0~63

0~71

0~8

0~7

0~7

NO(No), YES(Yes)

TRX(TRX), TRU(TRU/DTRU), QTRU(QTRU), DRRU(DRRU),


DRFU(DRFU), MRRU(MRRU), MRFU(MRFU), GRFU(GRFU),
GRRU(GRRU), BTS3900B(BTS3900B), BTS3900E(BTS3900E)

1~31

8~255

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

TS1(Time_slot_1), TS2(Time_slot_2), TS3(Time_slot_3),


TS4(Time_slot_4), TS5(Time_slot_5), TS6(Time_slot_6),
TS7(Time_slot_7), TS8(Time_slot_8), TS9(Time_slot_9),
TS10(Time_slot_10), TS11(Time_slot_11), TS12(Time_slot_12),
TS13(Time_slot_13), TS14(Time_slot_14), TS15(Time_slot_15),
TS16(Time_slot_16), TS17(Time_slot_17), TS18(Time_slot_18),
TS19(Time_slot_19), TS20(Time_slot_20), TS21(Time_slot_21),
TS22(Time_slot_22), TS23(Time_slot_23), TS24(Time_slot_24),
TS25(Time_slot_25), TS26(Time_slot_26), TS27(Time_slot_27),
TS28(Time_slot_28), TS29(Time_slot_29), TS30(Time_slot_30),
TS31(Time_slot_31)

1~31

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31
TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

0~7

0~512

NO(No), YES(Yes)

0~65535

1~144

0~127

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12,
TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22,
TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31

0~23

1~31

0~7

0~50

0~65535

Close(Close), Open(Open)

8K(8K), 16K(16K), 32K(32K), 64K(64K)

0~254

TRXLOOPBACK(TRX Loopback Test), CHLLOOPBACK(Channel


Loopback Test), CHLCODEC(Speech codec Test),
CPRILOOPBACK(CPRI Loopback Test)
0~31

SIMPLETEST(Simple Test), MANUALTEST(Manual Test)

PIM(Passive Intermodulation Test)

NO(No), YES(Yes)

CHAIN(Chain), RING(Ring)

1~255
1~128

0~8

HOUR, MINUTE

HOUR, MINUTE

DISABLE(Disable), ENABLE(Enable), SLEEPING(Sleeping)

0~100

40~79

-99~99

1~60

1~60

1~60

1~60

1~60

1~60

1~60

TX_3(3), TX_4(4), TX_5(5), TX_6(6), TX_7(7), TX_8(8), TX_9(9),


TX_10(10), TX_11(11), TX_12(12), TX_14(14), TX_16(16),
TX_20(20), TX_25(25), TX_32(32), TX_50(50)

0~10000

0~10000

0~10000

0~10000

0~10000

0~10000

0~10000

0~10000

1~3000000

0~4000000

T_2(2), T_3(3), T_4(4), T_5(5), T_6(6), T_7(7), T_8(8), T_9(9),


T_10(10), T_12(12), T_14(14), T_16(16), T_20(20), T_25(25),
T_32(32), T_50(50)
200~10000

GSM900, DCS1800, GSM850, PCS1900

EPS, TCS

GSM900, DCS1800, GSM900_DCS1800, GSM850, PCS1900,


GSM850_1800, GSM850_1900

OUTER(External PCU), INNER(Built-in PCU)

ANY_ERR_RETURN(Stop at Error), ALL_END_RETURN(Stop at End)

BTS30(BTS30), BTS312(BTS312), BTS3001C(BTS3001C),


BTS3001CP(BTS3001CP), BTS3002C(BTS3002C),
BTS3012A(BTS3012A), BTS3006A(BTS3006A),
BTS3012(BTS3012), BTS3006C(BTS3006C),
BTS3002E(BTS3002E), BTS3012AE(BTS3012AE),
BTS3012_II(BTS3012 II), DBS3900_GSM(DBS3900 GSM),
BTS3900_GSM(BTS3900 GSM), BTS3900A_GSM(BTS3900A GSM),
DBS3036(DBS3036), BTS3036(BTS3036), BTS3036A(BTS3036A),
BTS3900B_GSM(BTS3900B GSM), BTS3900E_GSM(BTS3900E
GSM), BTS3900_GSM_6RFC(BTS3900 GSM 6RFC),
BTS3900A_GSM_6RFC(BTS3900A GSM 6RFC),
BTS3036_6RFC(BTS3036 6RFC), BTS3036A_6RFC(BTS3036A
6RFC), APM30(APM30), TMC(TMC), BBC(BBC), APM100(APM100),
APM200(APM200), PS4890(PS4890), OMB(OMB), RFC-6(RFC-6),
BTS3900(BTS3900), BTS3900L(BTS3900L),
BTS3900AL(BTS3900AL), BTS3900AS(BTS3900AS),
BTS3900B(BTS3900B), BTS3900E(BTS3900E), VIRTUAL(VIRTUAL)

GSM900(GSM900), DCS1800(DCS1800)

0~15

NO(NO), YES(YES)
1(1), 2(2), 3(3), 4(4), 5(5), 6(6), 7(7), 8(8), 9(9), 10(10), 11(11),
12(12)
0~1,255

0~23,255

0~53,255

0~15

NO(NO), YES(YES)
1(1), 2(2), 3(3), 4(4), 5(5), 6(6), 7(7), 8(8), 9(9), 10(10), 11(11),
12(12)
0~1,255

0~23,255

0~53,255

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~15

OFF(Off), ON(On)

NO(No), YES(Yes)

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~15

OFF(Off), ON(On)

NORTPCOMP, RTPCOMP

NORTPCOMP, RTPCOMP

1214~2001,2005~3783,3786~4783,4785~65000

0~65535

Administrators(Administrator), Operators(Operator), Users(User),


Guests(Guest), Customs(Custom)

0~99

0~64
300~1000
None

None

0~255

1~30

1~30

1~30

1~30

1~8

1~8

1~255

0~240

1~64

0~63

1~64

1~64

1~10

1~30

1~30

1~30

1~30

0~15

0~15

0~15

0~15

0~15

0~15

0~15

0~15

1~100

1~20

1~30

1~30

1~100

0~3

0~7

0~7

1~20

0~7

0~63

0~70

0~70

0~70

0~10

0~19

0~63

0~63

1~20

0~10

0~19

1~20

0~100

0~100

0~63

0~63

0~63

0~63

0~63

0~63

0~63

0~63

0~63

0~63

NO(No), YES(Yes)

1~64

NO(Not Allowed), YES(Allowed)

0~255

GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus

NO(NO), YES(YES)

1~6

10~3500

10~3500

10~3500

10~3500

10~3500

10~3500

0~2047

0~2047

BYNAME(By Name), BYID(By Index)

BYNAME(By Name), BYID(By Index)

None

None

0~15

CS1(CS1), CS2(CS2), CS3(CS3), CS4(CS4)

MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4),


MCS5(MCS5), MCS6(MCS6), MCS7(MCS7), MCS8(MCS8),
MCS9(MCS9)

10~70

MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4),


MCS5(MCS5), MCS6(MCS6), UAS7(UAS7), UAS8(UAS8),
UAS9(UAS9), UAS10(UAS10), UAS11(UAS11)

MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4),


MCS5(MCS5), MCS6(MCS6), UAS7(UAS7), UAS8(UAS8),
UAS9(UAS9), UAS10(UAS10), UAS11(UAS11), UNFIXED(UNFIXED)

0~5000

CS1(CS1), CS2(CS2), CS3(CS3), CS4(CS4), UNFIXED(UNFIXED)

MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4),


MCS5(MCS5), MCS6(MCS6), MCS7(MCS7), MCS8(MCS8),
MCS9(MCS9), UNFIXED(UNFIXED)

0~70

0~63

10~255

0~96

NO(No), YES(Yes)

0~2047
512~1535

1~16

1~10

1~16

NO(No), YES(Yes)

0~300

0~64

0~64

0~64

0~64

0~64

0~64

FORBID(Forbid), PERMIT(Permit)

BYTMSI(By TMSI), BYIMSI(By IMSI), BYMSISDN(By MSISDN),


BYIMEI(By IMEI)

NOTSUPPORT(Not Support), SUPPORT(Support)

None

None

HOUR, MINUTE

HOUR, MINUTE

-99~99

0~8

0~255

0~63

NO(No), YES(Yes)

1~255

1~63

FDD(FDD), TDD(TDD)

None

0~190,255

No_Priority~0||()$$(No Priority)**
Public_Network_First~1||()$$(Public Network First)**
VGCS_First(No Priority)** Public_Network_First~1||()$$
(Public Network First)** VGCS_First~2||()$$(VGCS First)

0~190

50~95

NO(No), YES(Yes)
NONE(None), LEVEL4(User Level 4), LEVEL3(User Level 3),
LEVEL2(User Level 2), LEVEL1(User Level 1), LEVEL0(User Level
0), LEVELB(User Level B), LEVELA(User Level A)

50~95

DISABLE(Disable), ENABLE(Enable)

DISABLE, ENABLE

DISABLE(DISABLE), ENABLE(ENABLE)

DISABLE(DISABLE), ENABLE(ENABLE)

2~4094

2~4094
2~4094
2~4094

2~4094

2~4094

0~7

0~7

NO(N0), YES(Yes)

FULL_RATE_VER1, FULL_RATE_VER2, FULL_RATE_VER3,


HALF_RATE_VER1, HALF_RATE_VER2, HALF_RATE_VER3,
FULL_RATE_VER5

CLOSE(Close), OPEN(Open)

None

None

CLOSE(Close), OPEN(Open)

None

None

NO(NO), YES(YES)

0~12

1~30

14(1.4), 15(1.5), 16(1.6), 18(1.8), 20(2.0), 22(2.2), 24(2.4),


26(2.6), 28(2.8), 30(3.0), 33(3.3), 36(3.6), 88(8.8)

18(1.8), 20(2.0), 22(2.2), 24(2.4), 26(2.6), 28(2.8), 30(3.0),


32(3.2), 35(3.5), 38(3.8), 41(4.1), 45(4.5), 88(8.8)

0~12

0~999

4000~33000

3000~34000

3000~34000

0~1000

1~30

0~60

0~1000

INACTIVE(Inactive), ACTIVE(Active)

CLOSE(Close), OPEN(Open)

NOLIMIT(No Limit), LIMIT(Limit)


East_Longitude(East Longitude), West_Longitude(West
Longitude)

INACTIVE(Inactive), ACTIVE(Active)

NO(NO), YES(YES)

DENY(Deny), ALLOW(Allow)

SUN(Sunday), MON(Monday), TUE(Tuesday), WED(Wednesday),


THU(Thursday), FRI(Friday), SAT(Saturday)
M3UA_ASP(M3UA_ASP), M3UA_IPSP(M3UA_IPSP)

0~24

NO(No), YES(Yes)

1~255

0~24

NO(No), YES(Yes)

Active(Format active area), Standby(Format standby area)

GSM_AND_UMTS(GSM AND UMTS), UMTS(UMTS), GSM(GSM)

GO(GSM Only)

E1_UNBA(E1 Unbalance), E1_BA(E1 Balance), T1(T1), E1(E1)

E1(E1), T1(T1)

1~127

30~300

60~300

30~60000

GMT-1200(GMT-12:00), GMT-1100(GMT-11:00), GMT-1000(GMT10:00), GMT-0930(GMT-09:30), GMT-0900(GMT-09:00), GMT0800(GMT-08:00), GMT-0700(GMT-07:00), GMT-0600(GMT-06:00),


GMT-0500(GMT-05:00), GMT-0430(GMT-04:30), GMT-0400(GMT04:00), GMT-0330(GMT-03:30), GMT-0300(GMT-03:00), GMT0200(GMT-02:00), GMT-0100(GMT-01:00), GMT(GMT),
GMT+0100(GMT+01:00), GMT+0200(GMT+02:00),
GMT+0300(GMT+03:00), GMT+0330(GMT+03:30),
GMT+0400(GMT+04:00), GMT+0430(GMT+04:30),
GMT+0500(GMT+05:00), GMT+0530(GMT+05:30),
GMT+0545(GMT+05:45), GMT+0600(GMT+06:00),
GMT+0630(GMT+06:30), GMT+0700(GMT+07:00),
GMT+0800(GMT+08:00), GMT+0845(GMT+08:45),
GMT+0900(GMT+09:00), GMT+0930(GMT+09:30),
GMT+1000(GMT+10:00), GMT+1030(GMT+10:30),
GMT+1100(GMT+11:00), GMT+1130(GMT+11:30),
GMT+1200(GMT+12:00), GMT+1245(GMT+12:45),
GMT+1300(GMT+13:00), GMT+1400(GMT+14:00)

Actual Value Range

Unit

0~70

None

0~70

None

1~8, step:0.1

TRUE, FALSE

None

NO, YES

None

10~255

10~255

IDLETSALLOC_0, IDLETSALLOC_1, IDLETSALLOC_2,


IDLETSALLOC_3

None

CLOSE, OPEN

None

0~100

per cent

NO, YES

None

10~3600

GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus

None

1~255

None

0~250

None

8BIT, 11BIT

None

0~65535

None

NO, YES

None

0~31

None

OSubcell, USubcell, NoPrefer

None

0~31

None

ULPRIORITY, NEUTRAL, DLPRIORITY

None

0~9

None

1~10

None

15~7200

NO, YES

None

Disable, Enable

None

CLOSE, OPEN

None

COMPUL0, COMPUL1, FLEX

None

4_75KBIT/S, 5_15KBIT/S, 5_90KBIT/S, 6_70KBIT/S,


7_40KBIT/S, 7_95KBIT/S, 10_2KBIT/S, 12_2KBIT/S

None

4_75KBIT/S, 5_15KBIT/S, 5_90KBIT/S, 6_70KBIT/S,


7_40KBIT/S, 7_95KBIT/S

None

0~7

None

NO, YES

None

1~255

min

60~300

61.0~300.0 (step: 0.1)

60.0~299.0 (step: 0.1)

60~300

NO, YES

None

0~254

None

0~50

ms

0~768

None

PORT0_CDEF, PORT1_CDEF

None

1~16777215

None

BYMANUAL, BYAUTO

None

0, 1, 2

None

OFF, ON

None

COMMON_DLD, QUICK_DLD1, QUICK_DLD2

None

Lock, Unlock, Shutdown

None

Lock, Unlock, Shutdown

None

Lock, Unlock, Shutdown

None

hour{0~23}
min{0~59}

None

0~100

None

OFF, ON

None

hour{0~23}
min{0~59}

None

RATIORULE

None

1~51 characters

None

1~51 characters

None

0~600

ms

0~60

dB

-60~-35, 0

dBm

0~1000

ms

0~15

dB

CLOSE, OPEN

None

10~100

None

1~10

1920~30720, step:480

ms

0~30240, step:480

ms

0~65534

None

BSC

None

1920~30720, step:480

ms

0~30240, step:480

ms

65334~65383

None

1~65535

None

1~65535

None

1~65535

None

1~65535

None

1~1024 characters

None

65033~65533

None

1~60

min

ALL, ONEBYONE

None

ALL, ONEBYONE

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

ABIS, A

None

0~100

per cent

0~100

per cent

0~100

per cent

0~100

per cent

0~100

per cent

0~100

per cent

NO, R3, R2, R2ANDR3

None

-12~12

dB

-23~-4

dBm

3~12

dB

-23~-4

dBm

-23~-4

dBm

FIXEDLEVEL, ADAPTIVE, FIXEDGAIN

None

CLOSE, OPEN

None

5~15

None

1~255

0~4000000

kbit/s

NOTALLOW, ALLOW

None

OFF, ON

None

0~100

per cent

NOTALLOW, ALLOW

None

0~16

None

0~100

per cent

ALLCIC, ALLNULL

None

ALLCIC,
ALLNULL

None

0~2000

mA

0~2000

mA

0~2000

mA

0~2000

mA

0~2000

mA

0~2000

mA

0~65535

NO, YES

None

0~65534

None

0~65535

None

0~15

mA

45~155

mA

125~175

mA

0~65535

0~100

per cent

0~100

per cent

0~250

None

0~250

None

NO, YES

None

flt, evt, all

None

0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10

None

0~0.9, step:0.1

-1000~10000

0~6553

-3281~32810

feet

Critical, Major, Minor, Warning

None

Critical, Major, Minor, Warning

None

DISABLED,
ENABLED

None

DISABLED,
ENABLED

None

DISABLED,
ENABLED

None

DISABLED,
ENABLED

None

DISABLED,
ENABLED

None

DISABLED,
ENABLED

None

2~32, step:2

dB

OFF, ON

None

NO, YES

None

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

0~3

None

0~7

None

0~7

None

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

0~7

None

0~63

dB

0~63

dB

0~63

dB

NO, YES

None

0~255

dB

0~255

dB

0~255

dB

0~255

dB

0~7

None

0~100

per cent

0~255

dB

0~255

dB

NO, YES

None

0~7

None

0~100

per cent

0~32

dB

0~30

dB

0~30

dB

0~30

dB

0~32

dB

NO, YES

None

480~7200, step:480

ms

0~4

dB

0~15

None

OFF, ON

None

0~99

per cent

NO, YES

None

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

0~3

None

0~7

None

0~7

None

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

0~7

None

0~63

dB

0~63

dB

0~63

dB

0~65535

None

0~65535

None

3~30

dB

CLOSE, OPEN

None

10~30

dB

1~5 characters

None

0~4599

None

0~4599

None

1~100 characters

None

MODE0, MODE1, MODE2

None

-32~0

dB

-64~0

dB

CLOSE, OPEN

None

0~360

degree

0~1000

SENDPOWER, NOPOWER

None

OFF, ON

None

NO, YES

None

0~35

None

A, B

None

A, B

None

A, B, NULL

None

0~335

None

M3UA, BBAP

None

MTP2, OTHER, TCSTM1

None

1~65535

packet

1~65535

bit

1~65535

bit

1~65535

packet

1~65535

packet

1~65535

packet

CLOSE, OPEN

None

1~65535

bit

0~65535

None

PRIMARY, STANDBY, ALL

None

PRIMARY, STANDBY

None

0~80

per cent

5~126

None

5~100

per cent

3~10

None

3~10

ms

0~27

None

0~27

None

0~11

None

power, env, sig, trunk, hardware, software, run,


comm, service, handle

None

power, env, sig, trunk, hardware, software, run,


comm, service, handle

None

OFF, ON

None

DISABLE, ENABLE

None

0~61

dB

0~62, 255

None

0~62

None

0~23, 255

None

0~23

None

0~255

None

0~254

None

0~63

dB

500~60000

ms

1~300

1~300

1~300

1~300

1~300

1~300

1~300

NO, YES

None

0~63

dB

0~63

dB

NO, YES

None

Close, Open

None

80~100

per cent

0~254

None

0~100

per cent

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

NO, YES

None

0~1

None

0~254

None

0~2047

None

TDM, IP

None

A, B, ALL

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

NO, YES

None

0~15

dB

0~15

dB

1~65535

min

1~60

min

SERVER, CLIENT

None

SERVER, CLIENT

None

SERVER, CLIENT

None

NONE, PEER

None

1~64 characters

None

1~63 characters

None

1~63 characters

None

1~16 characters

None

1~15 characters

None

1~15 characters

None

NO_V, PAP_V, CHAP_V

None

NO_V, PAP_V, CHAP_V

None

NO_V, PAP_V, CHAP_V

None

ENABLE, DISABLE

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

DISABLED, ENABLED

None

BTSAUTODLDACT, TMUAUTOACT

None

OFF, ON

None

1~65535

min

AU4, AU3

None

GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus

None

LOW, HIGH

None

LOW, HIGH

None

O1E3_R1E4, O1E4_R1E5, O1E5_R1E6, O1E6_R1E7,


O1E7_R1E8, O1E8_R1E9, O1E9_R1E10, O1E10_R1E11, None
O1E11_R1E12

O1E3_R1E4, O1E4_R1E5, O1E5_R1E6, O1E6_R1E7,


O1E7_R1E8, O1E8_R1E9, O1E9_R1E10, O1E10_R1E11, None
O1E11_R1E12

O1E4_R1E5, O1E5_R1E6, O1E6_R1E7, O1E7_R1E8,


O1E8_R1E9, O1E9_R1E10, O1E10_R1E11

None

O1E4_R1E5, O1E5_R1E6, O1E6_R1E7, O1E7_R1E8,


O1E8_R1E9, O1E9_R1E10, O1E10_R1E11

None

OFF, ON

None

OFF, ON

None

0~128 characters

None

0~200 characters

None

0~70

None

CLOSE, LOCALTLLI, ALLTLLI

None

1~64 characters

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

BYTRX, BYPWR

None

BYCOVER, BYCAP, BYSAVING

None

0~1

None

0~1

None

0~1

None

1~200

1~80 characters

None

0~2047

None

Battery1Temp, Battery2Temp

None

Battery1Temp, Battery2Temp

None

30~1000

Ah

NO, YES

None

0~90

per cent

NO_BAT, INSIDE_BAT, OUTSIDE_BAT

None

1024~65535

None

0~254

None

0~5000

Ah

0~7

None

0~7

None

0~7

None

0~1023

None

0~1023

None

NO_Hop, Hop

None

0~100

per cent

0~100

per cent

0~63

None

0~511

None

5~25

per cent

43.3~57.6 (step: 0.1)

NO, YES

None

1~10

None

1~10

None

1~10

None

MTP3, M3UA, MTP3_M3UA

None

1~60

0~10

None

0~3

None

NO, YES

None

NO, YES

None

0.5~16, step:0.5

0.5~16, step:0.5

3~10

None

1~2

None

10~254

None

ALL, PART

None

-10000~10000

None

1~10

None

1~10

None

1~10

None

DISABLE, ENABLE

None

0~65534

60~65534

DISABLE, ENABLE

None

1~6

None

1~120

0~335

None

0~5, 8~27

None

0~11

None

0~5000

NO, YES

None

nonrpt, rpt

None

0, 1, 2, 3, 4, 5, 6, NULL

None

0, 1, 2, 3, 4, 5, 6, NULL

None

NO, YES

None

0.5~8, step:0.5

0~127

dB

0.5~8, step:0.5

SCU, GCU, XPU, INT, TNU

None

SCU, GCU, XPU, DPU, INT, TNU

None

SCU, GCU, MPU, GCP, DPU, INT, TNU

None

INT, DPU, XPU, TNU, OMU, SAU

None

0~72

None

0~47

None

0~100000 (step: 100)

kbit/s

DATM_MAIN, DATU_MAIN, DDPM_MAIN, DDPU_MAIN,


DDRM_MAIN, DEMU_MAIN, DFCU_MAIN, DGPS_MAIN,
DHEU_MAIN, DOMU_MAIN, DPMU_MAIN, DPTU_MAIN,
DRFU_MAIN, DRFUBOOT_MAIN, DRRU_MAIN,
DRRUBOOT_MAIN, DRU_MAIN, DTCU_MAIN,
DTMU_MAIN, DTRU_MAIN, ETR_MAIN, FMU_MAIN,
FMUA_MAIN, GATM_MAIN, GTMU_MAIN, IASU_MAIN,
IOMU_MAIN, MFU_3001C, MMU_3001C, MRRU_MAIN,
MTR_MAIN, NFCB_MAIN, PBU_MAIN, QTRU_MAIN,
TMU_MAIN, TRX_MAIN, GRRU_MAIN, BTS3900B_MAIN,
BTS3900BBOOT_MAIN, MRFU_MAIN, GRFU_MAIN,
MRRUBOOT_MAIN, MRFUBOOT_MAIN, USCU_MAIN,
BTS3900E_MAIN, BTS3900EBOOT_MAIN,
BOOTROM_PCK, UBRI_MAIN, UTRP_MAIN

None

0~100000 (step: 100)

kbit/s

DPUa, DPUc

None

PEUa, FG2a, GOUa, EIUa, OIUa, POUc, FG2c, GOUc,


XPUa, XPUb, DPUa, DPUb, DPUc, DPUd, TNUa, OMUa,
OMUb, SAUa

None

FG2a, GOUa, FG2c, GOUc

None

PEUa, POUc

None

PEUa, POUc

None

PEUa, POUc

None

MRRU, GRRU, MRFU, GRFU, BTS3900E

None

TMU, DTRU, DPTU, QTRU, MRRU, GRRU, BTS3900B,


MRFU, GRFU, BTS3900E, DRFU, DRRU, UBRI, UTRP

None

0~255

1~80 characters

None

2~3600

ENTIRE, INCREMENTAL

None

0~7

None

1~16777215

None

NO, YES

None

MAINBSC, SUBBSC

None

0.0.0.0~255.255.255.255

None

hour{0~23}
min{0~59}

None

hour{0~23}
min{0~59}

None

0~15

None

0~15

None

5~60

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

UNCONDITIONALSTART, ATERCONGESTS,
PREFIXNUMBER

None

1~64 characters

None

NO, YES

None

NO, YES

None

0~335

None

0~65535

None

NO, YES

None

NO, YES

None

NO, YES

None

0~65535

None

0~65535

None

0~65535

None

0~4294967295

None

0~65535

None

0~65535

None

0~65535

None

0~65535

None

0~65535

None

0~65535

None

0~65535

None

0~65535

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

0~65535

None

0~65535

None

0~65535

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

0~65535

None

0~27

None

0~11

None

0~7

None

0~2500

None

0~15

None

1~15

None

1~31

None

0~15

None

NO, YES

None

0~12

None

940~4230, step: 470

ms

1~4

None

0~12

None

NEITHERSTART, BTSPRIORITY, BSCPRIORITY, BTSONLY,


None
BSCONLY

NONSUPPORT, BASIC, ENHANCED

None

NO, YES

None

PEUa, EIUa, OIUa, POUc

None

SCUa, GCUa, GCGa, PEUa, FG2a, GOUa, EIUa, OIUa,


POUc, FG2c, GOUc, XPUa, XPUb, DPUa, DPUb, DPUc,
DPUd, TNUa

None

SCUa, GCUa, GCGa, PEUa, FG2a, GOUa, EIUa, OIUa,


POUc, FG2c, GOUc, XPUa, XPUb, DPUa, DPUb, DPUc,
DPUd, TNUa, ALL

None

PEUa, POUc, EIUa, OIUa

None

PEUa, POUc, EIUa

None

PEUa, POUc, EIUa, OIUa

None

POUc, OIUa

None

POUc, OIUa

None

FG2a, GOUa, FG2c, GOUc, POUc

None

EIUa

None

CDU, PCDU, DCDU, CDUC, CDUP, RCDU, CDUR, CDUE,


EDU, PEDU, REDU, DEDU, EDUC, EDUP, EDUR, EDUE, None
DDPM_DDPU, DFCU, DFCB

BIE, PWC, EAC, EMUA, MCK, DTMU, DATM_DATU,


NFCB, EMU_DEMU, DPMU, DCBM_DCOM, DHEU,
ECOM, MFU, MPW, MCD, IASU, PTU, TMU, PSU, PMU,
APMU, 3001C_MFU, TEU, TES, PBU, DPBU, RPBU,
PPBU, SCU, MDU, UPEU, UEIU, FMU, FMUA, DTCU,
GATM, DGPS, USCU, UBRI, FAN, EMU, PMU, TCU, PSU,
UTRP

None

DRRU, DRFU, MRRU, XRRU, MRFU, GRFU, GRRU, XRFU,


None
BTS3900E
TRX_30_OR_DRU, TRX_GPRS, PTRX, ETRX, RTRX,
DTRX, RETR, DETR, EETR, PETR, MTR, TRU, QTRU

None

CDU, CDUC, CDUP, CDUR, CDUE, PCDU, RCDU, DCDU,


EDU, EDUC, EDUP, EDUR, EDUE, PEDU, REDU, DEDU, None
DDPM_DDPU, DFCU, DFCB

DATU, GATM, DRRU, MRRU, MRFU, GRFU, GRRU,


BTS3900E

None

CFGBM, CFGTC

None

CFGBM, CFGTC

None

NO, YES

None

1~64 characters

None

LOGICIP, PORTIP, PPP/MP

None

LOGICIP, PORTIP, PPP/MP

None

0~64 characters

None

CLOSE, OPEN

None

0~2047

None

0~2047

None

0~2047

None

0~2047

None

0~2047

None

BYNAME, BYID

None

BYIDX, BYNAME

None

0~2047, 65535

None

0.0.0.0~255.255.255.255

None

UNCONDITIONALSTART, ABISCONGESTS,
PREFIXNUMBER

None

0.0.0.0~255.255.255.255

None

BSC_Preprocessing, BTS_Preprocessing

None

1~64 characters

None

1~64 characters

None

1~2048 characters

None

OFF, ON

None

NO, YES

None

2~32, step:2

dB

OFF, ON

None

1~256 characters

None

1~250

None

BTS3900B_GSM, BTS3900E_GSM

None

BTS30, BTS312, BTS3001C, BTS3001CP, BTS3002C,


BTS3012A, BTS3006A, BTS3012, BTS3006C,
BTS3002E, BTS3012AE, BTS3012_II, DBS3900_GSM,
BTS3900_GSM, BTS3900A_GSM, DBS3036, BTS3036,
BTS3036A, BTS3900B_GSM, BTS3900E_GSM,
BTS3900L_GSM

None

BTS3012, BTS3006C, BTS3002E, BTS3012AE,


BTS3012_II, DBS3900_GSM, BTS3900_GSM,
BTS3900A_GSM, DBS3036, BTS3036, BTS3036A,
BTS3900L_GSM, BTS3900B_GSM, BTS3900E_GSM

None

0~1000000

BIULOOP, TRXSELFTEST

None

NO_BAT, INSIDE_BAT, OUTSIDE_BAT

None

10~255

YES, NO

None

2~65534

None

2~65534

None

1000~3000

ms

OFF, ON

None

0~200000

kbit/s

0~200000

kbit/s

0~100

per cent

0~100

per cent

0~200000

kbit/s

0~100

per cent

0~200000

kbit/s

0~100

per cent

0~100

per cent

0~200000

kbit/s

100~1000

per cent

FULL_DUPLEX, HALF_DUPLEX

None

0~100

per cent

20~100

per cent

BYIDX, BYNAME

None

C31NOTUSE, C31STANDARD

None

0~1

None

1~200 characters

None

0~8

None

NO, YES

None

NO, YES

None

0~4095

None

NO, YES

None

OFF, ON

None

GSM900, DCS1800, GSM850, PCS1900

None

NULL, IPLGCPORT, RSCGRP

None

ETHER, IPLOGICPORT, TRUNK, PPP, MP

None

ETHPORT, TRUNK

None

NO, YES

None

0~3

None

0.0.0.0~255.255.255.255

None

0~63

None

0~65535

None

5~180

NO, YES

None

4500~32767

byte

1~5

TCH:0~14880, step:480; SDCCH:0~14570, step:470

ms

TCH:0~14880, step:480; SDCCH:0~14570, step:470

ms

0~65535

None

DISABLE, ENABLE

None

0~255

20~100

per cent

0~63

None

10, 100, 1000

ms

0~100

per cent

0~42, step: 6

dB

0~36, Positive infinity, step: 6

dB

0~1023

None

AUTO, MANU

None

0~1023

None

AUTO, MANU

None

0~50

None

0~42, step: 6

dB

0~36, Positive infinity, step: 6

dB

Permit, NoPermit

None

OUTDOOR_CELL, INDOOR_CELL

None

24.0~28.9 (step: 0.1)

43.3~57.6 (step: 0.1)

24.0~28.9 (step: 0.1)

43.2~57.5 (step: 0.1)

0~2047

None

0~2047

None

0~2047, 65535

None

0~2047

None

0~2047

None

0~2047

None

1~400 characters

None

BYNAME, BYID

None

BYNAME, BYID

None

BYNAME, BYID

None

Inner, Extra

None

1, 2, 3, 4

None

0~5000 characters

None

NO, YES

None

0~255

None

1~64 characters

None

1~64 characters

None

1~64 characters

None

0~5000 characters

None

OP1, OP2, OP3, OP4, NONE

None

0~63

dB

0~63

None

1~20

None

NO, YES

None

35.0~55.3 (step: 0.1)

2G, 3G

None

0~100

per cent

COMMON, MULTIPATH, INDOOR, HIGHWAY

None

NO, YES

None

40.0~79.0 (step: 0.1)

degree Celsius

-19.0~5.0 (step: 0.1)

degree Celsius

0.0~100.0 (step: 0.1)

degree Celsius

-50.0~0.0 (step: 0.1)

degree Celsius

NO, YES

None

0~63

dB

0~63

None

20~90

per cent

0~200 characters

None

NULL, IPLGCPORT, RSCGRP

None

NO, YES

None

AUTO, NORMAL

None

DISABLE, ENABLE

None

NO, YES

None

NO, YES

None

1~32 characters

None

G_15, G_16, G_17, G_18, G_19, G_20, G_21, G_22,


G_23, G_24, G_25, G_26, G_27, G_28, G_29, G_30,
G_31

None

G_0, G_1, G_2, G_3, G_4,


G_10, G_11, G_12, G_13,
G_18, G_19, G_20, G_21,
G_26, G_27, G_28, G_29,

None

G_5, G_6, G_7, G_8, G_9,


G_14, G_15, G_16, G_17,
G_22, G_23, G_24, G_25,
G_30, G_31

20~90

None

20~90

None

OFF, ON

None

0~2

None

1~32 characters

None

30~100

None

30~100

None

30~100

None

QUICK_HO_NCELL_TYPE_A, QUICK_HO_NCELL_TYPE_B

None

CHAINTORING, COMBINECHAINS

None

CAPABILITY, QUALITY, PSRELATIVELY, PSABSOLUTELY

None

0~100

per cent

OFF, ON

None

0~100

per cent

0~65535

None

NO, YES

None

NO, YES

None

1~64

1~5

None

NO, YES

None

MODE1, MODE2, MODE3

None

MODE1, MODE2, MODE3

None

0~511

None

0~511

None

5~20

None

5~20

None

NO, YES

None

NO, YES

None

ALDER32, CRC32

None

SBFD, ARP, MBFD

None

0~12

1~7

None

0~169

None

0~7

None

TRXRFSELFLOOP, BIULOOP, BTSSPEECHLOOP,


TRXSPEECHLOOP

None

FULLTCH, HALFTCH

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NOSENDING, SYSTEMOPT, SENDING

None

NO, YES

None

OFF, ON

None

10~800

None

10~800

None

100~600000

ms

TCHFR, TCHHR, SDCCH8, MBCCH, CBCCH, BCH,


BCCH_CBCH, SDCCH_CBCH, PBCCH_PDTCH,
PCCCH_PDTCH, PDTCH, DPDCH

None

0~65535

None

0~65535

None

0~65535

None

0~65535

None

0~160

frame

1~12, step: 5

min

OFF, ON

None

1~100

per cent

1~60

NO, YES

None

NO, YES

None

NOTSENDING, SENDINGPRO, SENDING

None

NOTSENDING, SENDINGPRO, SENDING

None

NO, YES

None

NO, YES

None

64~100000, step:64

kbit/s

0~22

dB

0~27

None

0~11

None

UNSUPPORT, SUPPORT

None

NO, YES

None

ERR_PFM_1E6, ERR_PFM_5E6, ERR_PFM_1E5,


ERR_PFM_5E5, ERR_PFM_1E4, ERR_PFM_5E4,
ERR_PFM_1E3

None

INCLK, BSCCLK, EXCLK, IPCLK, TRANSCLK, GPSCLK,


UMCLK, PEERCLK

None

HW_DEFINED, PTP

None

GCUa, GCGa

None

INT_CLK, TRCBSC_CLK, EXTSYN_CLK, IP_TIME,


IP_TRANSFER, TRCGPS_CLK, UM_CLK, PEER_CLK

None

0~255

cleared, uncleared

None

0~255

1~200 characters

None

0~128 characters

None

0~19

None

1~3

None

0~62

None

0~62

None

0~62

None

0~62

None

None

1~60

0~4095

None

0~4095

None

0~31

None

0~3

None

NONE, AINTFBLOCK

None

1~150000

None

BTS3002C, BTS3012A, BTS3006A

None

BTS3012, BTS3012AE, BTS3006C, BTS3012_II,


BTS3002E, DBS3900_GSM, BTS3900_GSM,
BTS3900A_GSM, DBS3036, BTS3036, BTS3036A,
BTS3900_GSM_6RFC, BTS3900A_GSM_6RFC,
BTS3036_6RFC, BTS3036A_6RFC

None

10000~50000

None

0~250

None

0~250

None

NO, YES

None

1~1023

None

INACTIVE, ACTIVE

None

BYSITE, BYCELL

None

0~10, step:0.1

dB

L0_FORBID, L1_FORBID, L2_FORBID, L3_FORBID,


L4_FORBID, L5_FORBID, L6_FORBID, L7_FORBID,
L8_FORBID, L9_FORBID

None

LOWERCASE, UPPERCASE, DIGIT, SPECIALCHARACTER None

1~100

None

NO, YES

None

BYNAME, BYID

None

10~150

ms

10~150

ms

10~150

ms

10~150

ms

10~150

ms

10~150

ms

10~150

ms

10~150

ms

10~150

ms

10~150

ms

10~150

ms

10~150

ms

NO, YES

None

0~335

None

NO, YES

None

INNER, EXTERNAL

None

ALL, ONLY_SSL

None

0~60

1~200

NO, YES

None

1~28

None

1~60

NO, YES

None

0~7

None

OFF, ON, NOTSUPPORT

None

0dB, 2dB, 4dB, 6dB, 8dB, 10dB, 12dB, 14dB

dB

0~200 characters

None

DISABLE, ENABLE

None

10~2550, step: 10

ms

1~255

None

0~126, step: 2

dB

1~255

None

UNAVAILABLE, AVAILABLE

None

VOICEINF, MR, CALLAPPENDINF, CALLINNERINF

None

0~100

None

OFF, ON

None

RESINSUFF, UMABNORM, TRAFFREJECT, MSCREL,


MSCDISCON, BADQUALITY

None

0~100

per cent

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32,


None
AF33, AF41, AF42, AF43, EF

0~7

None

0~100

per cent

0~7

None

OFF, ON

None

OFF, ON

None

OFF, MRHOFAIL, MRHOLATEST

None

COMMONUSRM, SPECUSRM

None

ABNORMREC, ALLBSCREC, ALLCELLREC

None

OFF, ON

None

OFF, ALL, AINTF, ABISINTF

None

30~100

per cent

LU, SMS, CALL

None

0~100

per cent

OFF, ON

None

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32,


None
AF33, AF41, AF42, AF43, EF

0~7

None

0~100

per cent

0~7

None

ON, OFF

None

40000~50000

ms

5000~150000

ms

1000~2000

ms

400~600

ms

7500~9500

ms

80~120

ms

3000~6000

ms

500~2000

ms

1~100

ms

30~100

per cent

30~100

per cent

1~16777215

None

4BURST, RLC/MAC

None

YES, NO

None

0~62

None

0~5

None

0~23

None

0~254

None

0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26

None

0~27, 255

None

0~11, 255

None

ON, OFF

None

NO, YES

None

0~99

None

10~255

min

1~63 character

None

TCH:480~14880, step:480; SDCCH:470~14570,


step:470

ms

TCH:480~14880, step:480; SDCCH:470~14570,


step:470

ms

NT14_5K, NT12K, NT6K, T14_4K, T9_6K, T4_8K, T2_4K,


None
T1_2K, T600_BITS, T1200_75

2000-1-1~2099-12-31

None

NOLIMIT, LIMIT

None

1~12

None

0~31

None

0~30

degree Celsius

Inner, Extra

None

0~2047

None

1~64 characters

None

BYNAME, BYID

None

0~255

None

0~255

None

0~255

None

0~255

None

35.0~55.6 (step: 0.1)

58.0~60.0 (step: 0.1)

43.3~55.5 (step: 0.1)

58.0~60.0 (step: 0.1)

0~32

None

500~60000

ms

0~186

None

1~110 characters

None

INACTIVE, ACTIVE

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

1~1000

None

BSC, BTS

None

BTS, BSC, DXX, OTHER

None

0~27

None

{0~11}

None

0~7

None

0~3071

None

0~255

3~10

None

OFF, ON

None

0~50 characters

None

0~35

None

0.0.0.0~255.255.255.255

None

LOGIC_IP

None

0~16383

None

0~23

None

0~254

None

NO, YES

None

DEFAULTPORT, CUSTOMPORT

None

1~60

min

0.0.0.0~255.255.255.255

None

0~63

None

DISABLE, ENABLE

None

NO, YES

None

MON_1~MON_31

None

SUN, MON, TUE, WED, THU, FRI, SAT

None

1~128 characters

None

1~256 characters

None

NO, YES

None

NO, YES

None

NO, YES

None

0~15

NO, YES

None

0.5~4, step: 1/8

bit

0.5~4, step: 1/8

bit

0.5~4, step: 1/8

bit

N0, YES

None

TCH:480~122400, step:480; SDCCH:470~119850,


step:470

ms

1~30

dB

1~30

dB

1~30

dB

1~30

dB

16~1007

None

1~255

None

UNSUPPORT, SUPPORT

None

0~63

dB

1~10

None

1~30

dB

1~30

dB

0~127

None

1~30

dB

1~30

dB

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~63

dB

0~70

None

1~100

None

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

2~255

None

2~255

None

2~255

None

2~255

None

1~30

dB

1~30

dB

1~100

None

0~3

None

0~7

None

0~7

None

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

0~7

None

0~63

dB

0~70

None

0~70

None

0~70

None

0~10

None

TCH:0~9120, step:480; SDCCH:0~8930, step:470

ms

0~63

dB

0~63

dB

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

0~10

None

TCH:0~9120, step:480; SDCCH:0~8930, step:470

ms

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

0~100

None

0~100

None

0~63

dB

0~63

dB

0~300

ms

0~255

1~255

None

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~255

None

0~255

None

0~255

None

CS1, CS2, CS3, CS4

None

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7,


MCS8, MCS9

None

MCS1, MCS2, MCS3, MCS4, MCS7, MCS8, DAS5, ,


DAS6, DAS7, DAS8, DAS9, DAS10, DAS11, DAS12

None

MCS1, MCS2, MCS3, MCS4, MCS7, MCS8, DAS5, ,


DAS6, DAS7, DAS8, DAS9, DAS10, DAS11, DAS12,
UNFIXED

None

CS1, CS2, CS3, CS4, UNFIXED

None

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7,


MCS8, MCS9, UNFIXED

None

NO, YES

None

NO, YES

None

0~5000

ms

0~64

per cent

0~64

per cent

0~64

per cent

0~64

per cent

0~64

per cent

0~64

per cent

CLOSE, OPEN

None

0~25.5, step:0.1

dB

1~16383(BIT14), 1~65535(BIT16),
1~16777215(BIT24)

None

1~11 characters

None

0~31

None

0~31

None

0~31

None

STP, A, IUR_G, LB

None

0~186

None

0~182

None

0~128

dB

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

0~1

None

10~150

ms

10~150

ms

10~150

ms

10~150

ms

10~150

ms

10~150

ms

1~60

min

0~12

2~10

dB

NO, YES

None

0, 1, 2, 4, 8, 16, 32, 64

INACTIVE, ACTIVE

None

0~31(PEUa), 0~251(E1 of POUc), 0~335(T1 of POUc)

None

0~335

None

0~63

None

0~63

None

0~63

None

0~63

None

1~3600

0~27

None

0 to 21

None

0~21

None

0~27

None

0~21

None

0~30

YES, NO

None

1~128 characters

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0~335

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

0~100

per cent

NO, YES

None

1~12

None

1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12

None

0, 1

None

0~1, 255

None

0~23

None

0~23, 255

None

0~53

None

0~53, 255

None

OFF, ON

None

FULL, HALF

None

0~12

1~24

0~59

min

0~59

10~80

None

0~63

None

0~2047

None

0~2047

None

0~15

None

10~3600

LEVEL0, LEVEL1, LEVEL2

None

0~8

None

NO, YES

None

NOTSUPPORT, DDIVERSITY, DPBT

None

1~60

min

0~7

None

0~31

None

ACTIVE, ACTIVESTANDBY, SLAVE1, SLAVE2, UTRP

None

0~7

None

0~83

None

16~19

None

E1, T1

None

0.0.0.0~255.255.255.255

None

0~49

dB

0~49

dB

NO, YES

None

1~2147483646

None

2000-1-1~2037-12-31

None

2000-1-1~2037-12-31

None

2000-1-1~2037-12-31

None

2000-01-01~2050-12-31

None

1~31

1~255

1~255

0~11

None

NO, YES

None

0.5~16, step:0.5

0.5~16, step:0.5

0.5~16, step:0.5

0.5~16, step:0.5

0.5~16, step:0.5

0.5~16, step:0.5

YES, NO

None

NO, YES

None

NO, YES

None

0~31

None

0~31

None

DATE, WEEK, DATEWEEK

None

1~15

None

OFF, ON

None

ERR_PFM_5E6, ERR_PFM_1E5, ERR_PFM_5E5,


ERR_PFM_1E4, ERR_PFM_5E4, ERR_PFM_1E3,
ERR_PFM_5E3

None

0~63

None

NO, YES

None

NO, YES

None

NoPriority, Priority4, Priority3, Priority2, Priority1,


Priority0, PriorityB, PriorityA

None

0~7

None

0~7

None

2~4094

None

JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT,
NOV, DEC

None

0.0.0.0~255.255.255.255

None

NO, YES

None

ENABLED, DISABLED

None

A5/0, A5/1, A5/2, A5/3, A5/4, A5/5, A5/6, A5/7

None

AUTO, PLAINTEXT, ENCRYPTED

None

AUTO, PLAINTEXT, ENCRYPTED

None

NO, YES

None

1~65535

None

0~65535

None

0~65535

None

1~31

None

-99.0~40.0 (step: 0.1)

degree Celsius

JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT,
NOV, DEC

None

0, 2, 4, 6

None

00:00~23:59

None

1~31, step:8

None

8~255

None

1~31

None

DISABLED, ENABLED

None

DISABLED, ENABLED

None

0~100

per cent

OFF, ON

None

OFF, ON

None

1~255

0~63

dB

0~100

per cent

OFF, ON

None

OFF, ON

None

0~100

per cent

NO, YES

None

M3UA_SGP, M3UA_IPSP, M3UA_SS7SP, M3UA_SP

None

M3UA_ASP, M3UA_IPSP

None

0~63

dB

OFF, ON

None

1~4294967295

None

NO, YES

None

O1E3_R5E4, O5E4_R1E4, O1E4_R5E5, O5E5_R1E5,


O1E5_R5E6, O5E6_R1E6

None

OFF, ON

None

0~63

None

0~7

None

0~7

None

2~4094

None

1~2147483646

None

500~60000

ms

CLOSE, OPEN

None

0~255

00:00:00~23:59:59

None

00:00:00~23:59:59

None

2000-1-1 00:00:00~2037-12-31 23:59:59

None

00:00~23:59

None

ONE_BY_ONE, PARALLEL

None

2000-1-1 00:00:00~2037-12-31 23:59:59

None

1970-1-1 00:00:00~2538-12-31 23:59:59

None

HOUR, MIN, SEC

None

2000-1-1~2037-12-31

None

00:00:00~23:59:59

None

LOGINEVENT, MANAGEEVENT, AUTHEVENT,


OTHEREVENT

None

00:00:00~23:59:59

None

SUN, MON, TUE, WED, THU, FRI, SAT

None

FIRST, SECOND, THIRD, FOURTH, LAST

None

1~9 characters

V or A

1~9 characters

V or A

VOLTAGE, CURRENT

None

1~9 characters

V or A

1~9 characters

V or A

1~9 characters

V or A

1~9 characters

V or A

VOLTAGE, CURRENT

None

1~9 characters

V or A

1~9 characters

V or A

1~9 characters

V or A

1~9 characters

V or A

VOLTAGE, CURRENT

None

1~9 characters

V or A

1~9 characters

V or A

1~9 characters

V or A

1~9 characters

V or A

VOLTAGE, CURRENT

None

1~9 characters

V or A

1~9 characters

V or A

NoExclusive, Exclusive

None

0~100

per cent

0~63

dB

0~63

dB

2048~5047

None

1~64 characters

None

5048~8047

None

1~64 characters

None

2048~5047

None

1~64 characters

None

CLOSE, OPEN

None

NO, YES

None

EM0, EM1

None

60sec, 120sec, 240sec, 480sec, 960sec, 1920sec,


3840sec, 7680sec

TYPE1, TYPE2, TYPE3

None

Normal_cell, DualTst_ExtCell

None

SEND, NOTSEND

None

0~12750, step: 50

ms

NO, YES

None

NO, YES

None

OFF, ON

None

OFF, ON

None

0~63

dB

PLUS_1, MINUS_1

None

HIGH_SPEED, LOW_SPEED

None

55~100

None

CONTINUOUS, DISCRETE, DUTY_RATIO

None

NORMAL_FAN, IND_FAN

None

NO_SPEED_ADJUSTMENT,
HW_AUTO_TEMPERATURE_CONTROL, SPECIFY_RATE,
SOFTWARE_CONTROL

None

IND_FAN, NORMAL_FAN

None

0~100

per cent

NO, YES

None

OFF, ON

None

CLOSE, OPEN

None

OFF, ON

None

0~100

per cent

0~1999

None

0~1999

None

0~1999

None

0~1999

None

0~1999

None

10~1999

None

2~1999

None

0~62

None

0~62

None

0~100

per cent

None, 16bit, 32bit

None

None, 16bit, 32bit

None

ON, OFF

None

43.2~57.5 (step: 0.1)

AUTO, MANU

None

AUTO, MANU

None

0~42, step: 6

dB

0~36, Positive infinity, step: 6

dB

0~1

None

0~16383

None

0~49

dB

0~3

None

-20, -6, -18, -8, -16, -10, -14, -12

dB

0~7

dB

Negative infinity, -28~28, step: 4

dB

RSCP, EcN0

None

-114~-84, step: 2

dBm

0~63

None

0~511

None

1~1000

None

NO, YES

None

0~1000

per mill

0~1000

per mill

0~1000

per mill

0~1000

per mill

0~1000

per mill

0~1000

per mill

0~1000

per mill

NO_FH, BaseBand_FH, RF_FH, Hybrid_FH

None

1~200 characters

None

1~128 characters

None

0~200 characters

None

0~128 characters

None

txt, csv

None

0~32

None

FALSE, TRUE

None

NO, YES

None

INACTIVE, ACTIVE

None

0~100

per cent

0~65534

0~65534

DISABLE, ENABLE

None

60~65534

60~65534

FIX_16K_ABIS, FLEX_ABIS, SEMI_ABIS

None

OFF, ON

None

OFF, ON

None

0~65535

ms

0~65535

ms

OFF, ON

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

0~20

None

0~20

None

0~20

None

0~20

None

0~20

None

0~20

None

0~20

None

0~20

None

0~200

None

CLOSE, OPEN

None

0~19

None

INDOOR, OUTDOOR

None

0~128 characters

None

0~128 characters

None

0~100 characters

None

1~128 characters

None

1~100 characters

None

1~256 characters

None

1~256 characters

None

OPEN, CLOSE

None

1~300

0~30

Close, Open

None

NO, YES

None

NO, YES

None

0~31

None

0~23

None

1~30

ms

OFF, ON

None

OFF, ON

None

OFF, ON

None

128~1024

byte

0~255

None

-2715647~2715647

None

NO, YES

None

0~1023

None

ONTIME, DAILY_T, DAILY_C, WEEKLY_T, WEEKLY_C,


MONTHLY_T, MONTHLY_C

None

ONTIME, RELATIVE

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

0~1023

None

NO, YES

None

0~65535

None

PGSM900, EGSML25, EGSM35M, RGSML25,


GSM900_RGSM39M, DCS1800, PCS1900, GSM850,
EGSM24M, DCS1800_L, DCS1800_H

None

0~100

per cent

0~1023

None

LOOSE, TIGHT

None

1~800 characters

None

MainDiversity, MaximumMeanValue

None

NO, YES

None

May_Use, Shall_Use, Shall_NOT_Use

None

0~23

None

0~23

None

0~255

None

0~254

None

TXT, CSV

None

0~33

None

1~33

None

0~33

None

0~255

dB

0~600

0.5~16, step:0.5

0~255

dB

0~600

0.5~16, step:0.5

0~200000

kbit/s

0~200000

kbit/s

0~100

per cent

0~100

per cent

0~200000

kbit/s

0~100

per cent

0~200000

kbit/s

0~100

per cent

0~100

per cent

0~200000

kbit/s

-100~100

per cent

0~100

None

A0, U1

None

0~31

None

hour{0~23}
min{0~59}

None

0~100

None

OFF, ON

None

hour{0~23}
min{0~59}

None

NO, YES

None

OFF, ON

None

DEG, SEC

None

NO, YES

None

NO, YES

None

OFF, ON

None

0.5~4, step: 1/8

bit

NO, SupportAsInnPcu, SupportAsExtPcu

None

NO, SupportAsInnPcu, SupportAsExtPcu

None

0dB, 2dB, 4dB, 6dB, 8dB, 10dB, 12dB, 14dB

dB

GPRS, EGPRSNORCH, EGPRSPRICH, EGPRSSPECH,


NONGPRS

None

DB110, DB108, DB106, DB104, DB102, DB100, DB98,


DB96, DB94, DB92, DB90, DB88, DB86, DB84, DB82,
DB80, DB78, DB76, DB74, DB72, DB70, DB68, DB66, dB
DB64, DB62, DB60, DB58, DB56, DB54, DB52, DB50,
DB48, no use

10sec, 20sec, 30sec, 40sec, 50sec, 60sec, 70sec,


80sec, 90sec, 100sec, 110sec, 120sec, 130sec,
140sec, 150sec, 160sec, 170sec, 180sec, 190sec,
200sec, 210sec, 220sec, 230sec, 240sec, 250sec,
260sec, 270sec, 280sec, 290sec, 300sec, 310sec,
320sec, no use

0~7

None

0db, 10db, 20db, 30db, 40db, 50db, 60db, infinity, no


dB
use

GPS, GLONASS, GPSGlonass

None

1~60

min

NO, YES

None

0~100000000

None

0~100000000

None

0~65534

None

1~20 characters

None

0~512

None

0~2047

None

IP

None

LAC_CI, PLMN, LAC, CI

None

0~100

per cent

1~15

None

0~3

None

UNSUPPORT, SUPPORT

None

ECHOREPLY, UNREACH, SOURCEQUENCH, REDIRECT,


ECHO, ROUTERADVERT, ROUTERSOLICIT, TIMXCEED,
PARAMPROB, TSTAMP, TSTAMPREPLY, IREQ,
IREQREPLY, MASKREQ, MASKREPLY

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

NO, YES

None

0~255

dB

0~600

0.5~16, step:0.5

0~255

dB

0.5~16, step:0.5

NO, YES

None

NO, YES

dB

1000~600000

None

0~62

None

0.5~8, step:0.5

0.5~8, step:0.5

0~65535

None

0~65535

None

DCS1800, PCS1900

None

1~14

None

YES, NO

None

NO, YES

None

NO, YES

None

NO, YES

None

1~10

UNSUPPORT, SUPPORT

None

SysOpt, OSubcell, USubcell, NoPrefer

None

NO, YES

None

0~63

dB

0~63

dB

BYCELLNAME, BYCGI

None

1~64 characters

None

HOALGORITHM1, HOALGORITHM2

None

NO, YES

None

0~16

None

0~16

None

0~63

dB

0.5~16, step:0.5

0.5~16, step:0.5

0~49

dB

0.5~16, step:0.5

FREE, INCELL, OUTCELL, OUTST, OUTBSC, OUTSYS,


SPCELL

None

0~127

dB

0~61

dB

Pre_2G_Cell, Pre_3G_Cell, Pre_2G_CellThres

None

0~255

0~63

None

0~63

None

BaseBand_FH, RF_FH

None

NO, YES, NONE

None

0~63

dB

OFF, ON

None

0~63

None

0~23

None

NO_FH, BaseBand_FH, RF_FH

None

0~63

dB

1~60

min

0~63

dB

NO, YES

None

0.5~16, step:0.5

0.5~16, step:0.5

0.5~16, step:0.5

SINGLEHOST, PRIMHOST, SLAVEHOST

None

SINGLEHOST, PRIMHOST, SLAVEHOST

None

0~63

dB

0~63

dB

NO_HPANT, YES_HPANT, NONE

None

NO_HPANT, YES_HPANT

None

0~5

None

1~14

None

NO, YES

None

35.0~55.6 (step: 0.1)

NO, YES

None

NO, YES

None

NO, YES

None

May_Use, Shall_Use, Shall_NOT_Use

None

0~63

None

0~23

None

OFF, ON

None

0~254

None

SBFD, MBFD

None

-99~70

degree Celsius

0~30

degree Celsius

DISABLE, ENABLE

None

CLOSE, OPEN

None

1~9 characters

per cent

1~9 characters

per cent

0.0~100.0 (step: 0.1)

None

0.0~100.0 (step: 0.1)

None

0.0~100.0 (step: 0.1)

None

0.0~100.0 (step: 0.1)

None

1~30

min

180~1260

1~60

min

E1PORT0, E1PORT1, E1PORT2, E1PORT3,


OPTICALPORT0, OPTICALPORT1

None

MAINDOMU, SLAVEDOMU1, SLAVEDOMU2

None

60~600

0~23

dB

0~23

dB

NO, YES

None

0~10, Step: 0.5

TCH:480~1920, step:480; SDCCH:470~1880,


step:470

ms

0~14

dB

0~14

dB

0~63

dB

NO, YES

None

0~10, Step: 0.5

OFF, ON

None

OFF, ON

None

0~23

dB

0~10, Step: 0.5

0~23

dB

0~31

dB

NO, YES

None

2~600

0~63

dB

0~63

dB

0~22

dB

0~22

dB

0~63

dB

0, 1

None

5~40

None

NO, YES

None

0~63

dB

0~30

dB

0~10, Step: 0.5

0~16

None

0~63

None

2~600

0~50

dB

0~10

None

0~63

dB

0~160

dB

0~23

dB

NO, YES

None

OFF, ON

None

0~63

None

NO, UNDER, INNER, YES

None

NO, YES

None

0~23

dB

NO, YES, NULL

None

DISABLE, ENABLE

None

44~1024

byte

0~63

None

0~63

None

0~63

None

1~30

None

1~30, 100~32767

None

0~65535

None

0~255

None

0~255

None

0~63

None

BYNAME, BYID

None

BYNAME, BYID, BYCGI

None

BYNAME, BYID

None

BYNAME, BYID

None

BYNAME, BYID

None

BYIDX, BYNAME

None

BYNAME, BYID

None

BYNAME, BYID

None

0~255

None

BYTLLI, BYIMSI

None

BYCELL, BYBSC

None

YES, NO

None

0~3071

None

Positive, Minus

None

0~125

None

NO, YES

None

0~32

None

1~15 characters

None

1000~30000

ms

NO, YES

None

NO, YES

None

NO, YES

None

0~254

ms

1~5

None

NO, YES

None

NO, YES

None

0~255

bit

NO, YES

None

0~255

1~15 characters

None

1~15 characters

None

500~60000

ms

0~8

bit

1~30

0~360

degree

0~62

None

NO, YES

None

0.5~16, step:0.5

0.5~16, step:0.5

CELLCAPCLASS, NACCRELATED

None

CLOSE, OPEN

None

0~39

None

0~39

None

0~50

0~3

None

0~3

None

0~2

None

TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9,
TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17,
TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25,
TS26, TS27, TS28, TS29, TS30, TS31

None

NO, YES

None

NO, YES

None

0~2047

None

1~64 characters

None

NO, YES

None

1~255

0~63

dB

0~100

per cent

0~23

None

0~335

None

0~15

None

Degree, D_min_sec

None

NO, YES

None

0~23

None

0~27

None

0~254

None

0~11

None

2~3600

0~127

dB

INTBANI, INTBANII

None

0~127

dB

0~255

0.5~8, step:0.5

0.5~8, step:0.5

NO, YES

None

NO, YES

None

48~115

None

48~115

None

48~115

None

48~115

None

48~115

None

48~115

None

0~60

480~14880, step: 480

ms

NO, YES

None

1~100

None

NO, YES

None

NO, YES

None

1~49

dB

0~49

dB

1~49

dB

1~91

dB

0~91

dB

1~91

dB

NO, YES

None

{0~4}

None

1~10

1~240

0~31

None

0~63

dB

500~60000

ms

500~60000

ms

NO, YES

None

NO, YES

None

500~60000

ms

NO, YES

None

0~49

dB

1~255

0~91

dB

0~255

None

0~31

None

1~1440

min

30~1024

NO, YES

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0~100

per cent

0~100

per cent

No_HC, UDP/IP_HC, RTP/UDP/IP_HC

None

No_HC, UDP/IP_HC, RTP/UDP/IP_HC

None

0~5

None

0~5

None

0~12999

None

IP_OVER_FE/GE, IP_OVER_E1

None

IP_OVER_FE/GE, IP_OVER_E1

None

NO, YES

None

NO, YES

None

NO, YES

None

UNSUPPORT, SUPPORT

None

UNSUPPORT, SUPPORT

None

NO, YES

None

YES, NO

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

STATIC, DYNAMIC

None

NO, YES

None

NO, YES

None

YES, NO

None

NO, YES

None

NO, YES

None

NO, YES

None

YES, NO

None

NO, YES

None

NO, YES

None

NOT_CONFIG, CONFIG

None

1~64

None

1~30

None

TRUE, FALSE

None

0~65535

None

ABIS, A, ATER, IUR_G

None

PPP, MP

None

OVERLAID, UNDERLAID, NONE

None

CONVERT0, CONVERT1, CONVERT2, CONVERT3

None

0.5~16, step:0.5

0.5~16, step:0.5

Normal_cell, Concentric_cell, EDB_cell

None

OFF, ON

None

Hexadecimal, Character_String

None

0~124 characters

None

0~124 characters

None

NULL, 1byte, 16byte, 64byte

None

OFF, ON

None

Hexadecimal, Character_String

none

0~124 characters

None

0~124 characters

None

NULL, 1byte, 16byte, 64byte

None

OFF, ON

None

Hexadecimal, Character_String

None

NULL, 1BYTE, 16BYTE, 64BYTE

None

0~64 characters

None

0~64 characters

None

ZERO, SPACE

None

DISABLE, ENABLE

None

1~255, (step: 20)

ms

DENY, ALLOW

None

NOT-INDICATE-END, INDICATE-END

None

0~63

dB

1~30

1~65533, 65535

None

1~65533, 65535

None

STATIC_LACP, MANUAL_AGGREGATION

None

1~5 characters

degree

0~90

degree

0~90

degree

0~59

minute

0~9

second

0~59

second

-90~90, step: 0.000001

degree

-90:00:00.000~90:00:00.000

SEC

100~10000, step:100

ms

0~100

None

0~10000

ms

0~15

None

0~15

None

1, 2, 3, 4

None

1, 2, 3, 4

None

0~100

None

0~300

0~300

CLOSE, PSDOWN, AMRC, CSPH, CSFHHO

None

CLOSE, PSDOWN, AMRC, CSPH, CSFHHO

None

CLOSE, PSDOWN, AMRC, CSPH, CSFHHO

None

0~186

None

0~7

None

ON, OFF

None

INFO, WARN, ERR, AST

None

CRITICAL, MAJOR, MINOR

None

NO, YES, NONE

None

NO, YES

None

0~63

dB

0.5~16, step:0.5

0.5~16, step:0.5

IP, Abis_IP

None

OAM, TDM_Switching, GCP, RGCP, MCP, GTC, GPCU, IP,


FR, HDLC, TDM, GbIP, Abis_TDM, Ater_TDM, Pb_TDM, None
A_TDM, Abis_IP, SAU

TDM_Switching, GCP, RGCP, MCP, GTC, GPCU, IP, FR,


HDLC, TDM, GbIP, Abis_TDM, Ater_TDM, Pb_TDM,
A_TDM, Abis_IP

None

A/Gb, Abis/Ater/Pb/Gb

None

5120~5375

None

0~99

None

90~99

per cent

70~95

per cent

0~17407

None

DIFFERENCE, ALL

None

64K, 2M

bit/s

1~8 characters

None

0~9 characters

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

0~40

40~80

LUCENT_MODE, HUAWEI_MODE, ALCATEL_MODE

None

8K, 16K, 32K, 64K, 2M

None

M3UA_MASTER_MOD, M3UA_SLAVE_MOD

None

B0000, B0001, B0010, B0011, B0100, B0101, B0110,


B0111, B1000, B1001, B1010, B1011, B1100, B1101,
B1110, B1111

None

B0000, B0001, B0010, B0011, B0100, B0101, B0110,


B0111, B1000, B1001, B1010, B1011, B1100, B1101,
B1110, B1111

None

0~100

per cent

RANDOMALG, OTHERALG

None

1~10

0~1000

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

-64dB ~ 63dB

None

0~255

0~63

dB

1~255

1~63

dB

1~16

None

0~63

dB

NO, YES

None

FORBID, PERMIT

None

0~63

None

0~100

per cent

0~100

per cent

NO, YES

None

NOTSTADYNPDCH, DYNPDCHASOCCUPY,
DYNPDCHASIDLE

None

OFF, ON

None

0~65534

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0~1023

None

0~1

None

0~35

None

0~35

None

1~200 characters

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

OFF, ON

None

1024~65535

None

LFB, CL

None

NORMMODE, RAPMODENOSERV, RAPMODERESSERV

None

30~100

per cent

30~100

per cent

NO, YES

None

0~988

None

0~5, 8~27

None

30~100

per cent

30~100

per cent

ON, OFF

None

PFM_RESULT, HOST_PFM_RESULT,
ACTIVE_DEF_MEAS_FILE, STANDBY_DEF_MEAS_FILE,
PFM_SWITCHS, HISTORY_ALARM, HISTORY_FAULT,
ALM_SYSTEM_CFG, SECURITY_LOG, OPT_LOG,
OMU_LOG, BSC_CFG_MML, CELL_BASIC_INFO,
BSC_SERIES_NO, DB_BAK, MEM_DB_BAK,
None
BTS_BASIC_INFO, BTS_CHECK_LOG, BTS_DEBUG_LOG,
BTS_CHR_LOG, TRX_LOG, BTS_NET_TABLE,
DEBUG_LOG, LAST_WORD, DSP_DEBUG_LOG,
HOST_LOG, 2G_CHR_LOG, 2G_UNILATERAL_CONNECT,
BSC_INFO, GCSR_LOG, GPSR_LOG, AIDG_LOG,
BIOS_LOG

COMLOG, CMPLOG

None

1~5 characters

degree

0~180

degree

0~180

degree

0~59

minute

0~9

second

0~59

second

-180~180, step: 0.000001

degree

-180:00:00.000~180:00:00.000

SEC

1~3

None

BYLOCAL, BYREMOTE

None

OFF, ON

None

LOOPTYPE_TDM, LOOP_TYPE_LVDS, LOOPTYPE_MCC

None

0~100

per cent

MSC, MS

None

NSSAINTF, NSSTCTOABIS, NSSTCTOA, NSSTNUTOABIS,


NSSTNUTOA, NSSATERINTF, BSSATERINTF,
None
BSSTCTOABIS, BSSTCTOA, BSSTNUTOABIS,
BSSTNUTOA, BSSABISINTF, BTSTMU, BTSTRUDSP

NO_LOOP, REMOTE_LOOP, LINE_REMOTE_LOOP,


LOCAL_LOOP, PAYLOAD_LOOP, SIN_CHN_LOC,
CIN_CHN_REM

None

NO_LOOP, REMOTE_LOOP, LOCAL_LOOP

None

60~600

1~100

None

NO, YES

None

NO, YES

None

OFF, ON

None

OFF, ON

None

NO, YES

None

NO, YES

None

E1, TIMESLOT

None

0~988

None

FG2a/GOUa board:0~119;FG2c board:0~489,


512~767;GOUc board:0~499,
512~767;POUc(IP)board:0~988, 1024~1535

None

FG2a/GOUa/UOIa(IP) board:0~119;FG2c board:0~489,


512~767;GOUc board:0~499, 512~767;POUc(IP)
None
board:0~988, 1024~1535
0~5, 8~27

None

Hub, Leaf

None

IR, LA

None

DISABLE, ENABLE

None

35.0~55.6 (step: 0.1)

CLOSE, PSDOWN, AMRC, CSPH, CSFHHO

None

EXCLUDE, INCLUDE

None

HORIZONTAL, VERTICAL

None

HORIZONTAL, VERTICAL

None

APPLICATION, SCNDCPU_PROG, BOOTROM, DATA, DSP,


None
FAN

OPTLOG, SECLOG

None

OPTLOG, SECLOG

None

-99~70

degree Celsius

-99~99

degree Celsius

2~255

None

2~255

None

2~255

None

2~255

None

0~12

None

14, 15, 16, 18, 20, 22, 24, 26, 28, 30, 33, 36, 88

None

18, 20, 22, 24, 26, 28, 30, 32, 35, 38, 41, 45, 88

None

DISABLE, ENABLE

None

1024~65535

None

0~8191

None

0~100

per cent

0~100

per cent

CA_MA, Frequency_List, OPTIMIZED_CA_MA

None

0~499

None

NO, YES

None

NO, YES

None

00:00~23:59

None

0~3, Step:0.2

dB

00:00~23:59

None

1~64 characters

None

1~64 characters

None

0~35

None

0~1

None

0~9999

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~2000

mA

0~2000

mA

0~2000

mA

0~2000

mA

0~2000

mA

0~2000

mA

1~20 characters

None

1~20 characters

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0~32

dB

0~254

None

64~100000, step:64

kbit/s

1~20

None

0~5

None

0~5

None

0~20

dB

1~2

None

1~2

None

24~1031

byte

50~200

None

1~1500

None

1~1500

byte

1~255

None

10000~150000

None

100~100000 (step: 100)

0~254

None

0~100

None

0~8

None

0~100

per cent

0~5

None

1~255

1C, 2C, 3C, 4C, 5C, 6C, 7C, 8C, 9C, 10C, 11C, 12C,
13C, 14C, 15C, 16C, 17C, 18C, 19C, 20C, 21C, 22C,
23C, 24C, 25C, 26C, 27C, 28C, 29C, 30C, 31C, 32C,
33C, 34C, 35C, 36C, 37C, 38C, 39C, 40C, 41C, 42C,
43C, 44C, 45C, 46C, 47C, 48C, 49C, 50C, 51C, 52C,
53C, 54C, 55C, 56C, 57C, 58C, 59C, 60C, 61C, 62C,
63C, 64C, 65C, 66C, 67C, 68C, 69C, 70C, 71C, 72C,
73C, 74C, 75C, 76C, 77C, 78C, 79C, 80C, 81C, 82C,
83C, 84C, 85C, 86C, 87C, 88C, 89C, 90C, 91C, 92C,
93C, 94C, 95C, 96C, 97C, 98C, 99C

None

5C, 7C, 10C, 12C, 15C, 18C, 20C, 22C, 25C

None

1~255

None

1_Times, 2_Times, 4_Times, 7_Times

None

1_Times, 2_Times, 4_Times, 7_Times

None

1_Times, 2_Times, 4_Times, 7_Times

None

1_Times, 2_Times, 4_Times, 7_Times

None

1~746

byte

1~746

None

0~30

dB

0~30

dB

0~30

dB

0~255

None

0~31

None

OFF, ON

None

0~255

None

1~24

0~32

None

2~255

None

0~32

dB

1~999

0~511

None

0.0.0.0~255.255.255.255

None

0~3

None

TCH:0~14880, step:480; SDCCH:0~14570, step:470

ms

TCH:0~14880, step:480; SDCCH:0~14570, step:470

ms

0~2047

None

1~64 characters

None

3 digit

None

1~3 characters

None

4(Use two bytes to present MC priority number, 4


classes), 8(Use four bytes to present MC priority
number, 8 classes)

None

4, 8

None

0~2047

None

1~64 characters

None

0~62

None

ON, OFF

None

CLASS0, CLASS1, CLASS2

None

0~7

None

0~7

None

1~20 characters

None

1~20 characters

None

NO, YES

None

1~5

EnhMeasReport, ComMeasReport

None

1~1000

None

1~8191

None

LocalMep,
RemoteMep

None

LONG, SHORT

None

LONG, SHORT

None

0~63

None

64~100000, step:64

kbit/s

0~49

dB

0~63

dB

10~3500

mA

10~3500

mA

0~2000

mA

0~2000

mA

0~2000

mA

0~2000

mA

0~2000

mA

0~2000

mA

10~3500

mA

10~3500

mA

0~63

dB

60~3600

0~63

dB

10~1000

ms

10~1000

ms

10~1000

ms

10~1000

ms

0~11

None

0~11

None

UP, DOWN

None

2~3 digit

None

1~64 characters

None

50~95

per cent

SERVER, CLIENT

None

CHECK_ON_INDEPENDENT_PORT,
CHECK_ON_PRIMARY_PORT,
CHECK_ON_STANDBY_PORT

None

MANUAL, AUTO, FREE

None

OFF, ON

None

GO, UO, GU

None

FIXED, CYCLE

None

MODE1, MODE2, MODE3, MODE4

None

MODE1,
MODE2,
MODE3

None

MODE1,
MODE2,
MODE3

None

MODE1,
MODE2,
MODE3

None

MODE1,
MODE2,
MODE3

None

MODE1,
MODE2,
MODE3

None

MODE1,
MODE2,
MODE3

None

30MINS, 60MINS, 120MINS, 240MINS

None

1~1440

0~12

None

0~600

m/s

0~100

per cent

0~100

per cent

0~3

None

0~31(PEUa), 0~167(POUc)

None

0~167

None

MODE1_1, MODE2_1, MODE3_1, MODE4_1, MODE5_1,


None
MODE6_1, MODE16K

0~1

None

DISABLE, ENABLE

None

MLPPP, MCPPP

None

0~27

None

0~11

None

NO, YES

None

0~31

None

1~255

None

NOreport, Twice_ps, Once_ps, Once_2s, Once_4s

None

4~30

dB

4~30

dB

OFF, ON

None

OFF, ON_WITH_SDCCH, ON_WITHOUT_SDCCH

None

128~1500

None

1~16

None

OFF, ON

None

0~65535

None

1~10

None

0~1023

None

NO, YES

None

OFFLOAD, NORMAL, UNAVAIL

None

R98_or_below, R99_or_above

None

5000~40000

ms

1~32 characters

None

1~10 characters

None

1~10 characters

None

1~10 characters

None

1~10 characters

None

1~10 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

NO, YES

None

1_Times, 2_Times, 4_Times, 7_Times

None

CLEAR, LOP, FS, MS, EXERS,

None

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7,


MCS8, MCS9

None

10~80

None

0~254

None

0~63

dB

0~255

None

1000~3000

ms

1~600

0~31

None

ON, OFF

None

50~95

per cent

ALARM_METHOD, LOOP_METHOD

None

0~31(EIUa/OIUa), 0~63(POUc)

None

MET, IMP

None

500~1500

None

0~1500

None

256~1650

byte

19.0~24.0, step:0.1

REPORT6, REPORT1, REPORT2, REPORT3

None

0~255

DISABLE, ENABLE

None

0~10

0~15

min

NO, YES

None

1~1500

ls

1~1500

ls

UDPMUX, ABISMUX, ATERMUX

None

0~12

None

1~16(FG2a/GOUa), 1~512(FG2c/GOUc)

None

1~3

None

5~254

None

34~254

None

29~254

None

OFF, ON

None

5~254

None

5~254

None

23~254

None

8~30

None

2~5

None

3~10

None

1~255

None

1~10

None

1~10

None

NO, YES

None

1~49 characters

None

1~49 characters

None

1~31 characters

None

1~31 characters

None

1~31 characters

None

1~49 characters

None

1~49 characters

None

1~31 characters

None

1~49 characters

None

1~31 characters

None

1~50 characters

None

1~31 characters

None

NO, YES

None

0~15

None

DISABLE, ENABLE

None

0~5047

None

1~64 characters

None

0~5047

None

1~64 characters

None

0~5047

None

1~64 characters

None

5048~8047

None

1~64 characters

None

OFF, ON

None

0~65535

None

1~65533, 65535

None

1~3 characters

None

1~3 characters

None

NO, YES

None

NOTSUPPORT, SUPPORT

None

NO, YES

None

0~7

None

0~7

None

SELECTION0_PERM,
SELECTION2_PERM,
SELECTION4_PERM,
SELECTION6_PERM,

SELECTION1_PERM,
SELECTION3_PERM,
SELECTION5_PERM,
SELECTION7_PERM

None

0~255

None

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

TCH:480~14880, step:480; SDCCH:470~14570,


step:470

ms

0~127

dB

0~127

dB

0~127

dB

0~127

dB

0~127

dB

0~127

dB

0~127

dB

0~127

dB

0~7

None

0~7

None

NC0, NC1, NC2

None

NO, YES

None

0.0.0.0~255.255.255.255

None

0~60

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

INT, INTB, NAT, NATB

None

1~62 characters

None

NMOI, NMOII, NMOIII

None

0~255

None

0~255

None

0~255

None

0~255

None

40~45

55~59

40~45

55~59

40~45

55~59

40~45

55~59

40~45

55~59

40~45

55~59

NO, YES

None

0~255

dB

0~255

dB

0~255

dB

0~255

dB

0~7

None

0~100

per cent

0~255

dB

0~255

dB

NO, YES

None

0~7

None

0~100

per cent

ABIS, A, BSC, TC, IUR_G

None

0~64

None

NO, YES

None

0~70

None

1~1000

Ah

OFF, ON

None

NODRX, 0.24sec, 0.48sec, 0.72sec, 0.96sec, 1.20sec,


1.44sec, 1.92sec

100~10000

ms

100~10000

ms

FORBID, PERMIT

None

40.0~70.0 (step: 0.1)

degree Celsius

CLOSE, OPEN

None

5~1275, step:5

min

10~255

1~10

None

TCH:0~14880, step:480; SDCCH:0~14570, step:470

ms

TCH:0~14880, step:480; SDCCH:0~14570, step:470

ms

0~1023

None

0~1023

None

NO, YES

None

0~65534

None

0~65534

None

TCH:480~14880, step:480; SDCCH:470~14570,


step:470

ms

North_latitude, South_latitude

None

0~65534

None

0~1023

None

0~30

degree Celsius

0~30

degree Celsius

1~255

None

0~100

per cent

0~100

per cent

0~100

per cent

0~100

per cent

0~100

per cent

0~63

None

OFF, ON

None

BYCELL, BYTRX

None

SITE, CELL, BOARD

None

0~499

None

0~499

None

ALL, BOARD, PORT, DSP

None

BTS, CELL, LOC, BOARD, PORT

None

CELL, TRX, CHN

None

OFF, ON

None

NO, YES

None

NO, YES

None

OFF, ON

None

4~255

0~63

None

0~256

kbit/s

0~256

kbit/s

0~7

None

0~7

None

2~4094

None

0~96

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

1~32 characters

None

1~16777215

None

1~16777215

None

0~4

None

PRIM, SEC

None

0~3

None

OPINDEX0, OPINDEX1, OPINDEX2, OPINDEX3

None

BYCICRANGE, BYCICVALUE

None

BYTSRANGE, BYTSVALUE

None

BYTSRANGE, BYTSVALUE

None

NORMAL, FORCE

None

BYCICRANGE, BYCICVALUE

None

0~255 characters

None

SysOpt, OSubcell, USubcell, NoPrefer

None

0~63

dB

0~255

bit

L0, L1, L2, L3, L4, L5, L6, L7

None

SDH, SONET

None

MANUAL, FORCED, CLEARALARMA

None

FORBID, RESTORE

None

0~4

None

0~7

None

One_touch, Step_by_Step

None

1~200 characters

None

0~36

None

0~63

dB

NO, YES

None

500~60000

ms

500~60000

ms

NO, YES

None

0~100

per cent

0~50

0~63

dB

NO, YES

None

1~255

1~255

0~63

dB

0~100

per cent

TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9,
TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17,
TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25,
TS26, TS27, TS28, TS29, TS30, TS31

None

0~335

None

0~15

None

0~31

None

HIGH, LOW

None

HIGH, LOW

None

HIGH, LOW

None

HIGH, LOW

None

1.0~200.0 (step: 0.1)

30.0~53.0 (step: 0.1)

dB

0.1dB, 0.1W

None

0~100

per cent

NO, YES

None

0~27

None

0~27

None

0~11

None

NO, YES

None

NO, YES

None

CLOSE, OPEN

None

1~60

0~255

None

10~3500

mA

10~3500

mA

10~3500

mA

10~3500

mA

10~3500

mA

10~3500

mA

100~10000

ms

100~10000

ms

1~255

40.0~70.0 (step: 0.1)

degree Celsius

50~95

per cent

50~95

per cent

50~95

per cent

50~95

per cent

NO, YES

None

NO, YES

None

10~65535

None

0~255

ms

10~65535

None

1~8

None

Pan_0, Pan_1, Pan_2, Pan_3, Pan_4, Pan_5, Pan_6,


Pan_7, 255

None

Pan_0, Pan_1, Pan_2, Pan_3, Pan_4, Pan_5, Pan_6,


Pan_7, 255

None

Pan_4, Pan_8, Pan_12, Pan_16, Pan_20, Pan_24,


Pan_28, Pan_32, 255

None

L0, L1, L2, L3, L4, L5, L6, L7

None

0~9999

None

0~99

None

ENABLED, DISABLED

None

0~65535

None

0~65535

None

0~25.5, step:0.01

dB

NO, YES

None

QoS, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31,


AF32, AF33, AF41, AF42, AF43, EF

None

MAINCPU_PATCH, DSP_PATCH, UCODE_PATCH

None

DB0, DB2, DB4, DB6, DB8, DB10, DB12, DB14, DB16,


DB18, DB20, DB22, DB24, DB26, DB28, DB30

dB

NO, YES

None

0.5~16, step:0.5

0~127

dB

0.5~16, step:0.5

0~65535

None

TCH:480~7200, step:480; SDCCH:470~7050,


step:470

ms

BCCH, PDCH

None

0~31

None

0~31

None

0~31

None

0~31

None

NO, YES

None

10~160

None

NO, YES

None

NO, YES

None

10~70

None

1~10

0~65534

None

0~65534

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0~2047

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

1024~65535

None

1~63 characters

None

NO, YES

None

0~255

0~63

None

0~255

15~720, step:15

min

1~60

NO, YES

None

Disable, Enable

None

Disable, Enable

None

NO, YES

None

0~2

None

10~1000

None

10~2000

None

100~600000

ms

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32,


None
AF33, AF41, AF42, , AF43, EF

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32,


None
AF33, AF41, AF42, AF43, EF

NO, YES

None

DISABLE, ENABLE

None

5~64

None

64~1024

byte

2~1500

byte

24~1031

byte

NO, YES

None

95~512

byte

20~1500

byte

0_level, 1_level, 2_level, 3_level, 4_level, 5_level,


6_level, 7_level, 8_level, 9_level, 10_level, 11_level,
12_level, 13_level, 14_level, 16_level, no use

None

0~10, step:0.2

dB

0_level, 1_level, 2_level, 3_level, 4_level, 5_level,


6_level, 7_level, 8_level, 9_level, 10_level, 11_level,
12_level, 13_level, 14_level, 16_level, no use

None

0_level, 1_level, 2_level, 3_level, 4_level, 5_level,


6_level, 7_level, 8_level, 9_level, 10_level, 11_level,
12_level, 13_level, 14_level, 16_level, no use

None

0~10, step:0.2

dB

0_level, 1_level, 2_level, 3_level, 4_level, 5_level,


6_level, 7_level, 8_level, 9_level, 10_level, 11_level,
12_level, 13_level, 14_level, 16_level, no use

None

0~10, step:0.2

dB

100~10000, step:100

ms

0~1, step:0.001

None

A, ABIS

None

OFF, ON

None

0~600

30~100

per cent

30~100

per cent

50~400, step: 50

ms

2~15

None

CLOSE, OPEN, AUTO

None

30~100

per cent

30~100

per cent

ON, OFF

None

0~335

None

0~335

None

0~11

None

0~11

None

0~3

None

1~32

None

0~335

None

0~255

None

0~335

None

0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc)

None

0~335

None

0~7

None

0~31(PEUa/EIUa), 0~62(E1 of OIUa), 0~83(T1 of


OIUa), 0~251(E1 of POUc), 0~335(T1 of POUc)

None

0~31(PEUa/EIUa), 0~62(E1 of OIUa), 0~83(T1 of


OIUa), 0~251(E1 of POUc), 0~335(T1 of POUc)

None

0~31(PEUa/EIUa), 0~62(E1 of OIUa), 0~83(T1 of


OIUa), 0~251(E1 of POUc), 0~335(T1 of POUc)

None

0~7

None

0(OIUa), 0~3(POUc)

None

0~7

None

0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc)

None

0~11

None

0~335

None

0~31

None

0~335

None

0~335

None

0~355

None

0~23

None

0~23

None

0~335

None

0~1

None

0~1

None

0~255

None

250~650

None

6~120

None

6~120

None

NotSupport, Support

None

0~9

None

0~9

None

0~250 characters

None

1~250 characters

None

21~65535

None

0~1

None

0~1

None

0~15

None

1~16

None

IP, HDLC

None

CLOSE, OPEN

None

ETHER, TRUNK

None

TOPEXTOUTPORT, TOPEXTINPORT

None

BCCHNorm, BCCHExt

None

BYBTSTYPE, BYBTS

None

0.1~100.0 (step: 0.1)

kVA

CLOSE, OPEN

None

CLOSE, OPEN

None

CLOSE, OPEN

None

CLOSE, OPEN

None

CLOSE, OPEN

None

CLOSE, OPEN

None

0~1000

None

0~10, step: 0.2

dB

0~10, step: 0.2

dB

POWER_48_24, POWER_240_24

None

220VAC, N48VDC, P24VDC

None

0~13

None

80W, 63W, 60W, 55W, 50W, 45W, 40W, 31W, 30W,


27W, 26W, 25W, 24W, 21W, 20W, 19W, 18W, 17W,
16W, 15W, 14W, 13_3W, 13W, 12_5W, 12W, 11_5W,
11W, 10W, 9_5W, 9W, 8_5W, 8W, 7_5W, 7W, 6_5W,
6W, 5_5W, 5W, 4_5W, 4W, 3_7W, 3_1W, 3W, 2_5W,
2W, 200mW, DEFAULT

None

0~100

per cent

0~100

per cent

0~15

None

0~499

None

0~499

None

0~499

None

Disable, Enable

None

0~5

None

YES, NO

None

ALLOWED, NOT_ALLOWED

None

OFF, ON

None

1~255

None

0~255

None

0, 3, 4, 5, 6

None

NO, YES

None

NO, YES

None

30~100

per cent

30~100

per cent

30~100

per cent

30~100

per cent

ON, OFF

None

PRIOR-1, PRIOR-2, PRIOR-3, PRIOR-4, PRIOR-5, PRIOR6, PRIOR-7, PRIOR-8, PRIOR-9, PRIOR-10, PRIOR-11,
PRIOR-12, PRIOR-13, PRIOR-14, PRIOR-15, PRIOR-16

None

Prior-1, Prior-2, Prior-3, Prior-4, Prior-5, Prior-6, Prior-7,


Prior-8, Prior-9, Prior-10, Prior-11, Prior-12, Prior-13,
Prior-14, Prior-15, Prior-16

None

0~100

per cent

0, 1, 2, 3, 4, 5, 6, 7, no use

None

0~99

None

0~99

None

HIGH, LOW

None

TDME1_O, TDME1_1, FE_E, FE_O, IPOE

None

1, 2

None

TDME1_O, TDME1_1, FE_E, FE_O, IPOE

None

0~200 characters

None

DEFAULT, CUSTOMIZDE, DISABLE

None

ITUT, ANSI, TTC

None

Q933, ANSI

None

5~300

0~255

min

60~3600

ALL, SINGLE

None

ALL, SINGLE

None

ALL, PORT, SINGLE

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

0~100

per cent

0~100

per cent

NO, YES

None

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32,


None
AF33, AF41, AF42, AF43, EF

0~7

None

0~7

None

1~16

None

NO, YES

None

BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32,


None
AF33, AF41, AF42, AF43, EF

0~7

None

0~7

None

0~63

None

COMMONUSRM, SPECUSRM

None

-121~-104

dBm

-121~-104

dBm

OFF, ON

None

10~10000

None

100~600000

ms

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

0~63

None

NO, YES

None

ON, OFF

None

0~31

BOOL, VALUE

None

BOOL, VALUE

None

GB_OVER_FR, GB_OVER_IP

None

123~65534

None

B8ZS, HDB3, AMI, AMI_ZCS

None

E1_DOUBLE_FRAME, E1_CRC4_MULTI_FRAME,
T1_SUPER_FRAME, T1_EXTENDED_SUPER_FRAME

None

E1_DOUBLE_FRAME, E1_CRC4_MULTI_FRAME,
T1_SUPER_FRAME, T1_EXTENDED_SUPER_FRAME

None

E1_DOUBLE_FRAME, E1_CRC4_MULTI_FRAME,
T1_SUPER_FRAME, T1_EXTENDED_SUPER_FRAME

None

0~15

None

FE, GE

None

APM100, APM200, APM30, EPS4890, EPS4815,


SC48200, CUSTOM

None

0~200 characters

None

1~50 characters

None

1~50 characters

None

1~65535

ms

1~32 characters

None

1~32 characters

None

0~64 characters

None

6~32 characters

None

0~31

None

BIT0, BIT1, BIT6, BIT7, BIT8, BIT9, BIT14, BIT15, BIT16,


None
BIT17, BIT22, BIT23, BIT24, BIT25, BIT29, BIT30, BIT31
BIT0, BIT1, BIT2, BIT3, BIT4, BIT5, BI16, BIT7, BIT8,
BIT9, BIT10, BIT11, BIT12

None

NO, YES

None

NO, YES

None

PWR2, PWR3

None

0~3

None

NO, YES

None

OnlyCurPwrLoc, ALLPwrLoc

None

CLASS0, CLASS1, CLASS2

None

0~720

min

NO, YES

None

DB0, DB2, DB4, DB6, DB8, DB10, DB12, DB14, DB16,


DB18, Default

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

0~63

None

0~63

None

0~63

None

0~63

None

0~63

None

Use_Qsearch_I, Always

None

NO, YES

None

1~10

None

0~255

1~10

None

-98, -94, -90, -86, -82, -78, -74, (always), -78, -74, -70,
None
-66, -62, -58, -54, Positive infinity(never)

TCH:480~15360, step:480; SDCCH:470~15040,


step:470

ms

TCH:480~15360, step:480; SDCCH:470~15040,


step:470

ms

NO, YES

None

-98, -94, -90, -86, -82, -78, -74, (always), -78, -74, -70,
None
-66, -62, -58, -54, Positive infinity(never)

-98, -94, -90, -86, -82, -78, -74, (always), -78, -74, -70,
None
-66, -62, -58, -54, Positive infinity(never)

NO, YES

None

1~16

1~16

NONE, DYNAMIC

None

3~20

None

3~20

None

0~4

dB

NO, YES

None

NO, YES

None

AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7

None

NO, YES

None

INSIDE_100AH, INSIDE_50AH, OUTSIDE_300AH,


OUTSIDE_400AH, OUTSIDE_500AH, OUTSIDE_650AH,
OUTSIDE_200AH

None

007C, 010C, 015C

None

INSIDE_BATTERY, OUTSIDE_BATTERY

None

AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7

None

NO, YES

None

INSIDE_100AH, INSIDE_50AH, OUTSIDE_300AH,


OUTSIDE_400AH, OUTSIDE_500AH, OUTSIDE_650AH,
OUTSIDE_200AH

None

007C, 010C, 015C

None

INSIDE_BATTERY, OUTSIDE_BATTERY

None

AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7

None

NO, YES

None

INSIDE_100AH, INSIDE_50AH, OUTSIDE_300AH,


OUTSIDE_400AH, OUTSIDE_500AH, OUTSIDE_650AH,
OUTSIDE_200AH

None

007C, 010C, 015C

None

INSIDE_BATTERY, OUTSIDE_BATTERY

None

0~255

None

0~255

None

0~255

None

0~255

None

0~255

None

0~255

None

-121~-104

dBm

0~63

dB

0~65535

None

-121~-104

dBm

0~7

None

NO, YES

None

0~255

None

0dB, 2dB, 4dB, 6dB, 8dB, 10dB, 12dB, 14dB, no use

dB

10M, 100M, AUTO

None

ALG1, ALG2, NONE

None

DISABLE, ENABLE

None

1~255

None

LASTRBP, APPOINTRBP

None

REC_ALL, REC_ERR, REC_NON

None

0~249

None

0~249

None

0~249

None

INDEPENDENT, DIVIDING, FOURDIVERSITY,


MAINDIVERSITY, NONE

None

0~100

None

NO, YES

None

Same_Band, Diff_Band

None

0~70

None

0~70

None

0~63

dB

0~63

dB

NO, YES

None

NO, YES

None

20~99

None

0~70

None

NO, YES

None

YES, NO

None

0~50

ms

0~768

None

0~31

None

0~31

None

0~31

None

0~31

None

OFF, ON

None

OFF, ON

None

NO, YES

None

0~95

None

00:00:00~23:59:59

None

1~3600

REHOSTRIGHTNOW, REHOSTDELAY, REHOSTWHEN

None

NO, YES

None

0~62

None

NO, YES

None

OFF, POWERSHARING, RF_FH

None

0~23

None

0~255

None

A, B, NONE

None

1~31 characters

None

1~250 characters

None

0~1023

None

0~65535

None

NO, YES

None

0~7

None

NO, YES

None

NO, YES

None

NO, YES

None

0~63

None

1~10

1~32

None

1~32

None

0~8

None

0~16

None

NO, YES

None

0~65535

min

1~60

min

1~255

None

1~15

min

1~120

MSLOST, QUALITYBAD, CELLRESELECT

None

NO, YES

None

NO, YES

None

2~5

2~5

Noneed, Manually, Reset, Normally, Correlative,


Configuration, Expired

None

0~86400

0~190

None

0~21

None

0~255

1~100

None

NO, YES

None

RGPS, GPS

None

NO, YES

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

1920~30720, step: 480

ms

STANDALONETC, MASTERINPOOLTC, SLAVEINPOOLTC

None

0~4095

None

0~16, 255

None

0~16

None

1~64 characters

None

0~200 characters

None

1~100

None

1~100

None

DISABLE, ENABLE, UNSUPPORT

None

0.48sec, 0.96sec, 1.92sec, 3.84sec, 7.68sec,


15.36sec, 30.72sec, 61.44sec

0.48sec, 0.96sec, 1.92sec, 3.84sec, 7.68sec,


15.36sec, 30.72sec, 61.44sec

20~99

None

NO, YES, NONE

None

TCH:0~14880, step:480; SDCCH:0~14570, step:470

ms

TCH:0~14880, step:480; SDCCH:0~14570, step:470

ms

0~2047

None

SHARE, EXCLUSIVE

None

SHARE

None

0~255

0~63

dB

0~63

dB

BASIS_OF_B1, BASIS_OF_B2

None

BASIS_OF_B1, BASIS_OF_B2

None

MINUS_52db, MINUS_48db, MINUS_44db,


MINUS_40db, MINUS_36db, MINUS_32db,
MINUS_28db, MINUS_24db, MINUS_20db,
MINUS_16db, MINUS_12db, MINUS_10db, MINUS_8db, dB
MINUS_6db, MINUS_4db, MINUS_2db, Zerodb, 2db,
4db, 6db, 8db, 10db, 12db, 16db, 20db, 24db, 28db,
32db, 36db, 40db, 44db, 48db, no use

0~64

kbit/s

0~63

None

0~7

None

0~64

kbit/s

2~4094

None

0~96

None

COMMISSIONING, UPGRADE, RESTORE

None

0~127

dB

1~63 character

None

1~50 characters

None

OFF, ON

None

1~65535

ms

0~190

None

OFF, ON

None

0~4294967295

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

0~3

None

NON-REVERTIVE, REVERTIVE

None

0~4294967295

None

1~5

per cent

OFF, ON

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0~15

None

0~100

per cent

0~100

per cent

500~60000

ms

500~60000

ms

500~60000

ms

DISABLE, ENABLE

None

10~80

None

NEXTHOP, OUTIF

None

0~1000

None

1~100

None

0~999

None

1~3000000

kbit/s

0~4000000

kbit/s

0~63

None

0~70

None

0~63

dB

NO, YES

None

0~70

None

0~70

None

0~70

None

0~70

None

0~70

None

0~70

None

0~70

None

0~70

None

0~70

None

0~70

None

0~70

None

0~70

None

0~249

None

0~249

None

0~249

None

RXUNAME, RXUPOS, SRNSN

None

RXUNAME, RXUPOS, SRNSN

None

1~64 characters

None

1~64 characters

None

1~64 characters

None

1~6

None

1~6

None

1~6

None

DRRU, DRFU, MRRU, MRFU, GRRU, GRFU, BTS3900E

None

OFF, ON

None

0~15

None

48VDISABLE,
RES0,
RES1,
RES2,
TSDISABLED,
HSDISABLED,
RES3,
RES4

None

BT1_DISABLE(0), AH_DISABLE(1), AT1_DISABLE(2),


AT2_DISABLE(3), BT2_DISABLE(4)

None

NO, YES

None

NO, YES

None

0~2

None

0~4

None

T1_DISABLE, ET_DISABLE, ET1_DISABLE,


ET2_DISABLE, T2_DISABLE

None

0~2047

None

BYNAME, BYID

None

1~16

None

0~100

per cent

1~64 characters

None

0~30240, step: 480

ms

WATER_IMMERSED, SMOG, GM_DISABLE

None

WIDISABLE,
SMDISABLE,
IMDISABLE,
GMDISABLE

None

WILOW,
SMLOW,
IMLOW,
GMLOW,

None

NO, YES

None

WS_DISABLE(0), SS_DISABLE(1), GS_DISABLE(2)

None

0~2047

None

1~64 characters

None

ADD0dB, ADD10dB, Automatic

None

0~63

None

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

0~2047

None

1~64 characters

None

GERMAN, ENGLISH, ITALIAN, FRENCH, SPANISH,


DUTCH, SWEDISH, DANISH, PORTUGUESE, FINNISH,
NORWEGIAN, GREEK, TURKISH, HUNGARIAN, POLISH,
GB2312, KOI8-R, KOI8-U, KOI8, WINDOWS-1251,
ASMO_449, WINDOWS-1256, WINDOWS-874,
WINDOWS-1253, WINDOWS-1254, WINDOWS-1255,
WINDOWS-1257, WINDOWS-1250, WINDOWS-1252,
BINARY, UCS2, RCS-1, RCS-2, RCS-3, RCS-4, RCS-5

None

0~1

None

Valid command string, without the ';'at the end of the


None
string.
BYBTSID, BYCELLID

None

0~23

None

0~511

None

1~2147483646

None

0~1199

None

2000-1-1~2037-12-31

None

2000-1-1~2037-12-31

None

7~90

2000-1-1~2037-12-31

None

1E-3, 1E-4, 1E-5, 1E-6, 1E-7, 1E-8, 1E-9

None

2000-01-01~2050-12-31

None

1~31

1~191

None

OFF, ON

None

0~10, step:0.1

0~63

dB

0~70

None

0~63

dB

0~70

None

NO, YES

None

DISABLE, ENABLE

None

OFF, ON

None

DISABLE, ENABLE

None

0~60

0~5

None

0~255

0~63

dB

0~63

None

HIGH, LOW

None

40~70

degree Celsius

0~65535

0~65535

35.0~55.6 (step: 0.1)

NO, YES

None

1~63 characters

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NoPriority, Priority4, Priority3, Priority2, Priority1,


Priority0, PriorityB, PriorityA

None

NoPriority, Priority4, Priority3, Priority2, Priority1,


Priority0, PriorityB, PriorityA

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

0~6

None

SUPPORT, UNSUPPORT

None

1000~65535

None

1000~65535

None

1~17 characters

None

0.0.0.0~255.255.255.255

None

SEPARATE, TOGETHER, AIP

None

TDM, HDLC, HubBTS, IP

None

TDM, HDLC, IP

None

SYSTEM, CONFIG, MAINTAIN, STAT, ALARM

None

OML, RSL, EML, ESL, CSVOICE, CSDATA, PSHIGHPRI,


PSLOWPRI, OTHERDATA

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

0~5

None

0~65535

None

1~20 characters

None

1~10

None

0~1023

None

NO, YES

None

Release 98 or older, Release 99 onwards

None

UNISTALL, ALLOW, DENY

None

50~95

per cent

0~27

None

NO, YES

None

unshielded, shielded

None

0~12

NO, YES

None

NO, YES

None

1~10

None

0~186

None

0~186

None

0~15

None

0~255

None

0~255

None

0~7

None

1~10

None

TCH:480~14880, step:480; SDCCH:470~14570,


step:470

ms

0~15

None

TCH:480~14880, step:480; SDCCH:470~14570,


step:470

ms

0~65535

ms

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

1~32 characters

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0~65535

None

0~255

None

0.0.0.0~255.255.255.255

None

0~35

None

E1SELFLOOP, IASUSELFLOOP

None

B0000, B0001, B0010, B0011, B0100, B0101, B0110,


B0111, B1000, B1001, B1010, B1011, B1100, B1101,
B1110, B1111

None

1~600

DATE, WEEK, DATEWEEK

None

0~3

None

NOTSUPPORT, INNER, OUTER

None

CLOSE, OPEN

None

JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT,
NOV, DEC

None

2~2000

None

0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26

None

0~27

None

0~3, 8~27

None

0~27

None

0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26

None

0~27

None

0~27

None

0~23

None

{0~27}

None

0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26

None

0~5, 8~27

None

0~5, 8~27

None

0~5, 8~27

None

0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26

None

0~27

None

0~27

None

0~23

None

0~23

None

0~27

None

0~7

None

NOCOMB, PBT, WBANDCOMB, DIVERSITY, DDIVERSITY,


None
DPBT, DTIC, NONE

SGL_ANTENNA, SGLDOUBLE_ANTENNA,
DOUBLE_ANTENNA, DOUBLEFOUR_ANTENNA,
DOUBLESINGLE_ANTENNA,
DOUBLEDOUBLE_ANTENNA

None

SGL_ANTENNA, SGLDOUBLE_ANTENNA,
DOUBLE_ANTENNA, DOUBLEFOUR_ANTENNA,
DOUBLESINGLE_ANTENNA,
DOUBLEDOUBLE_ANTENNA

None

SGL_ANTENNA, SGLDOUBLE_ANTENNA,
DOUBLE_ANTENNA, DOUBLEFOUR_ANTENNA,
DOUBLESINGLE_ANTENNA,
DOUBLEDOUBLE_ANTENNA

None

SGL_ANTENNA, SGLDOUBLE_ANTENNA,
DOUBLE_ANTENNA, DOUBLEFOUR_ANTENNA,
DOUBLESINGLE_ANTENNA,
DOUBLEDOUBLE_ANTENNA

None

SGL_ANTENNA, DOUBLESINGLE_ANTENNA,
DOUBLEDOUBLE_ANTENNA

None

1~60

min

1~16383(BIT14), 1~65535(BIT16),
1~16777215(BIT24)

None

BIT14, BIT16, BIT24

None

1~11 characters

None

0~65535

None

WNF, DNF

None

L11_FORBID, L12_FORBID, L13_FORBID, L14_FORBID,


L15_FORBID

None

ET_DISABLE0, ET_DISABLE1, SMDISABLE, WIDISABLE,


None
GMDISABLE, ARRESTER1, ARRESTER2

SMDISABLE, WIDISABLE, GMDISABLE, ARRESTER1,


ARRESTER2

None

1~12, step: 5

min

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

PSMODE, VGCSMODE

None

PSMODE, VGCSMODE

None

FR, EFR

None

1000M, AUTO

None

0~63

dB

0~255

NO, YES

None

NOTSPPRTBC, SPPRTSTANDARD, SPPRTSIMPLE

None

NO, YES

None

NO, YES

None

UNSUPPORT, SUPPORT

None

UNSUPPORT, SUPPORT

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

UNSUPPORT, SUPPORT

None

NO, YES

None

YES, NO

None

0~4

None

SUPPORT, NOT_SUPPORT

None

SUPPORT, NOT_SUPPORT

None

SUPPORT, NOT_SUPPORT

None

0~2047

None

1~64 characters

None

0~2047

None

1~64 characters

None

0~65535

None

1~100 characters

None

1~4

None

1~4

None

HOALGORITHM1, HOALGORITHM2

None

0.0.0.0~255.255.255.255

None

1~65533, 65535

None

1~3 characters

None

1~1000

None

1~3 characters

None

0~335

None

BITS1-2MHZ, BITS2-2MHZ, BITS1-2MBPS, BITS22MBPS, GPS, 8KHZ, LINE1_8KHZ, LINE2_8KHZ, BITS1T1BPS, BITS2-T1BPS

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

0~11

None

0~11

None

1~11

None

0~11

None

0~11

None

0~11

None

0~254

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~11

None

0~254

None

0~254

None

0~11

None

None

0~11

None

0~11

None

1~249 characters

None

0~5

None

MPS, EPS, TCS

None

DES, ASC

None

0~255

None

0~255

None

GSM_PRIOR, UMTS_PRIOR

None

CSVOICE, CSDATA, PSHIGHPRI, PSLOWPRI

None

0~63

dB

20~99

per cent

30~100

per cent

20~99

per cent

30~100

per cent

TCH:480~15360, step:480; SDCCH:470~15040,


step:470

ms

TCH:480~15360, step:480; SDCCH:470~15040,


step:470

ms

0~7

None

0~7

None

1~2147483646

None

0~63

dB

00:00:00~23:59:59

None

00:00:00~23:59:59

None

2000-1-1 00:00:00~2037-12-31 23:59:59

None

00:00~23:59

None

2000-1-1 00:00:00~2037-12-31 23:59:59

None

1970-1-1 00:00:00~2538-12-31 23:59:59

None

HOUR, MIN, SEC

None

1~65535

None

NO, YES

None

NO, YES

None

0~65535

None

0~65535

None

1~31

None

-99.0~40.0 (step: 0.1)

degree Celsius

JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT,
NOV, DEC

None

NO, YES

None

NO, YES

None

0, 2, 4, 6

None

60~600

00:00~23:59

None

1~31, step:8

None

8~255

None

1~31

None

DISABLED, ENABLED

None

DISABLED, ENABLED

None

0~65535

None

0~62

None

2000-1-1~2037-12-31

None

1~32

None

NO, YES

None

00:00:00~23:59:59

None

NO, YES

None

OFF, ON

None

60~300

OFF, ON

None

0~23

None

HOUR{0~23}, MIN{0~59}, SEC{0~59}

None

0~23

None

0~254

None

0~7

None

00:00:00~23:59:59

None

1~31

None

BTS30, BTS312, BTS3001C, BTS3001CP, BTS3002C,


BTS3012A, BTS3006A, BTS3012, BTS3006C,
BTS3002E, BTS3012AE, BTS3012_II, BTS3900_GSM,
BTS3900A_GSM, BTS3036, BTS3036A,
BTS3900L_GSM, BTS3900B_GSM, BTS3900E_GSM

None

1~15

None

1~15

None

1~64 characters

None

16~1023

byte

16~1023

byte

1~50

None

1~124, 128~189

None

NO, YES

None

NO, YES

None

0, 2, 4, 6

None

0~65535

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

NOTSUPPORT, SUPPORT

None

UNSUPPORT, SUPPORT

None

NOTSUPPORT, SUPPORT

None

UNSUPPORT, SUPPORT

None

NO, YES

None

NO, YES

None

NO, YES

None

T_12, T_15, T_20, T_30, T_41, T_55, T_76, T_109,


T_163, T_217

None

0.0.0.0~255.255.255.255

None

0~65535

None

CLOSE, OPEN

None

ON, OFF

None

OFF, ON

None

CLOSE, OPEN

None

ON, OFF

None

SUN, MON, TUE, WED, THU, FRI, SAT

None

CLOSE, OPEN

None

BFD_OFF, BFD_ON

None

ON, OFF

None

ON, OFF

None

NO, YES

None

CLOSE, OPEN

None

NO, YES

None

1~254

None

OFF, ON

None

0~4294967295

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

OFF, ON

None

0~4294967295

None

0~4294967295

None

0~4294967295

None

3~5

None

OFF, ON

None

FIRST, SECOND, THIRD, FOURTH, LAST

None

0~2500

None

SyncCase1, SyncCase2

None

AISS, GPS

None

CONSYN, INTERSYN

None

1~7

0~23

0~59

min

1~250 characters

None

1~250 characters

None

0, 8~11

None

1~250 characters

None

NO, YES

None

1~250 characters

None

1~250 characters

None

1~60

1000~30000

ms

30000~60000

ms

800~1500

ms

800~1500

ms

2000~3000

ms

800~1500

ms

800~1200

ms

1~60

1000~120000

ms

60~2400 (step: 10)

ms

5~1275, step: 5

ms

5~1275, step: 5

ms

10~2550, step: 10

ms

10~2550, step: 10

ms

10~2550, step: 10

ms

5~1275, step: 5

ms

5~1275, step: 5

ms

1~10

180000~360000

ms

180000~360000

ms

1400~2000

ms

1~60

1000~10000

ms

0~2550, step:10

ms

1~255

500ms, 1000ms, 1500ms, 2000ms, 2500ms, 3000ms,


ms
3500ms, 4000ms

0ms, 80ms, 120ms, 160ms, 200ms, 500ms, 1000ms,


1500ms

ms

0~1530, step: 6

min

5~30

800~1200

ms

1000~10000

ms

800~1200

ms

1000~30000

ms

800~1200

ms

1000~10000

ms

1000~10000

ms

800~1200

ms

TCH:480~14880, step:480; SDCCH:470~14570,


step:470

ms

NO, YES

None

NO, YES

None

0~255

bit

0.5~8, step:0.5

0~255

bit

0~255

TCH:480~14880, step:480; SDCCH:470~14570,


step:470

ms

0~7

None

0.5~0.8, step:0.5

0~255

bit

0~25

None

0~25

None

1~12

None

1~12

None

30~300

60~300

1~254

None

1000~10000

ms

0~500

mV

OFF, ON

None

NO, YES

None

0~100

per cent

0~1000

per mill

0~63

dB

0~70

None

0~1000

per mill

0~63

dB

0~70

None

0~60

0~10

None

NO, YES

None

1~600

OFF, ON

None

0~100

per cent

0~100

per cent

1~15

None

SEPERATE_PRINCIPAL, SEPERATE_SUBORDINATE,
TOGETHER, SEPERATE_BSC_INTERFACE

None

DISABLE, ENABLE

None

0~62

None

0~335

None

0~4095

None

0~5, 8~27

None

0~11

None

GTC, UTC, ITC

None

AUTO, Manual

None

AUTO, Manual

None

0~42, step: 6

dB

Negative infinity, -28~28, step: 4

dB

0~36, Positive infinity, step: 6

dB

0~1

None

0~16383

None

NO, YES

None

NO, YES

None

0~63

None

0~127

None

0~127

None

NO, YES

None

0~1

None

0~100

per cent

0~100

per cent

0~5

None

0~5

None

0~127

None

CLOSE, OPEN

None

1~9 characters

degree Celsius

1~9 characters

degree Celsius

-50.0~100.0 (step: 0.1)

degree Celsius

-49.0~100.0 (step: 0.1)

degree Celsius

-50.0~100.0 (step: 0.1)

degree Celsius

-50.0~99.0 (step: 0.1)

degree Celsius

0.0~500.0 (step: 0.1)

mV

1~64 characters

None

1~65535

None

32768~65535

None

1~64 characters

None

50~70

degree Celsius

-40.0~0.0 (step: 0.1)

degree Celsius

-40.0~0.0 (step: 0.1)

degree Celsius

NO, YES

None

1~255

1~615 characters(GB2312, KOI8-R, KOI8-U, KOI8,


WINDOWS-1251, ASMO_449, WINDOWS-1256,
WINDOWS-874, WINDOWS-1253, WINDOWS-1254,
None
WINDOWS-1255, WINDOWS-1257, WINDOWS-1250,
WINDOWS-1252, UCS2), 1~2462 characters(BINARY),
1~1395 characters(others)

OFF, ON

None

0~1023

0~65535

None

ACTIVE, STANDBY

None

0~255

None

0.0.0.0~255.255.255.255

None

0.0.0.0~255.255.255.255

None

0~5, 8~27

None

0~11

None

5000~60000

ms

220~280

220~280

1~10

None

1~10

None

1~10

None

1~10

None

1~10

None

1~10

None

1~10

None

1~10

None

1~10

None

PERCENTAGE, BANDWIDTH

None

1~15

min

0~63

dB

0~7

None

0.5~16, step:0.5

0~100

per cent

0.5~16, step:0.5

0~7

None

OFF, ON

None

0~63

dB

3~15

0, 5~1440

min

00:00:00~23:59:59

None

NOLIMIT, LIMIT

None

0~255

0~255

0~255

1~20 (step: 1)

ms

200~10000

ms

1~65535

ms

1~3

1~10

0~255

1~1024

None

NO, YES, NULL

None

0~255

10~255

1~30

1~15

min

7~365

0~4294967295

None

-99~70

degree Celsius

-19~5

degree Celsius

-99~99

degree Celsius

00:00~23:59

None

00:00~23:59

None

00:00~23:59

None

00:00~23:59

None

00:00~23:59

None

00:00~23:59

None

14~163

None

0~163

None

1~120

min

NON_FDR, FDR

None

2~4

0~100

per cent

0~4294967294

None

0~100

per cent

8000~12000

ms

30000~90000

ms

0~276

None

TRRS,
SATEL

None

TRRS, SATEL

None

0~7

None

-120~-1, 1~120

min

0~62

None

0~23

None

0~254

None

NORMAL, FORMAT

None

0~5

None

1~30

30~100

per cent

30~100

per cent

30~100

per cent

30~100

per cent

ON, OFF

None

1~255

None

1~255

None

M3UA_OVERRIDE_MOD, M3UA_LOADSHARE_MOD

None

TER_TRANS, SAT_TRANS, TER_AND_SAT_TRANS

None

0~27

None

IP

None

IP, HDLC

None

IP, HDLC, TDM

None

HDLC IP

None

IP, HDLC, TDM

None

NO, YES

None

NO, YES

None

NO, YES

None

NO, YES

None

ENABLE, DISABLE

5sec, 10sec, 15sec, 20sec, 30sec, 60sec, 120sec,


300sec, no use

0~100

None

0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc)

None

0~5, 8~27

None

0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc)

None

0~163

None

0~199

None

0~199

None

0~199

None

0~199

None

0~199

None

10~199

None

0~199

None

OFF, ON

None

0~11

None

0~11

None

0~11

None

TRXAid_NotAllow, AllowReForbid, AllowReImmed,


AllowReCheckRes

None

5~10

0~63, 255

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

0~3071

None

1~120 characters

None

0~63

None

0~71

None

0~8

None

0~7

None

0~7

None

NO, YES

None

TRX, TRU, QTRU, DRRU, DRFU, MRRU, MRFU, GRFU,


GRRU, BTS3900B, BTS3900E

None

1~31, step:8

None

8~255

None

2~4294967294

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

1~31

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

0~7

None

0~512

None

NO, YES

None

0~65535

None

10~1440 (step: 10)

min

0~127

None

1~50 characters

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10,
TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18,
TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26,
TS27, TS28, TS29, TS30, TS31

None

0~23

None

1~31

None

0~7

None

0~50

0~65535

ms

Close, Open

None

8K, 16K, 32K, 64K

kbit/s

0~254

None

TRXLOOPBACK, CHLLOOPBACK, CHLCODEC,


CPRILOOPBACK

None

0~31

None

SIMPLETEST, MANUALTEST

None

PIM

None

NO, YES

None

CHAIN, RING

None

1~255

None

1~128

0~8

None

00:00~23:59

None

00:00~23:59

None

DISABLE, ENABLE, SLEEPING

None

0~100

per cent

40~79

degree Celsius

-99~99

degree Celsius

1~60

1~60

1~60

1~60

min

1~60

min

1~60

1~60

TX_3, TX_4, TX_5, TX_6, TX_7, TX_8, TX_9, TX_10,


TX_11, TX_12, TX_14, TX_16, TX_20, TX_25, TX_32,
TX_50

None

0~100 (step: 0.01)

0~100 (step: 0.01)

0~100 (step: 0.01)

0~100 (step: 0.01)

0~100 (step: 0.01)

0~100 (step: 0.01)

0~100 (step: 0.01)

0~100 (step: 0.01)

1~3000000

kbit/s

0~4000000

kbit/s

T_2, T_3, T_4, T_5, T_6, T_7, T_8, T_9, T_10, T_12,
T_14, T_16, T_20, T_25, T_32, T_50

None

200~10000

ms

GSM900, DCS1800, GSM850, PCS1900

None

EPS, TCS

None

GSM900, DCS1800, GSM900_DCS1800, GSM850,


PCS1900, GSM850_1800, GSM850_1900

None

OUTER, INNER

None

ANY_ERR_RETURN, ALL_END_RETURN

None

BTS30, BTS312, BTS3001C, BTS3001CP, BTS3002C,


BTS3012A, BTS3006A, BTS3012, BTS3006C,
BTS3002E, BTS3012AE, BTS3012_II, DBS3900_GSM,
BTS3900_GSM, BTS3900A_GSM, DBS3036, BTS3036,
BTS3036A, BTS3900B_GSM, BTS3900E_GSM,
BTS3900_GSM_6RFC, BTS3900A_GSM_6RFC,
BTS3036_6RFC, BTS3036A_6RFC, APM30, TMC, BBC,
APM100, APM200, PS4890, OMB, RFC-6, BTS3900,
BTS3900L, BTS3900AL, BTS3900AS, BTS3900B,
BTS3900E, VIRTUAL

None

GSM900, DCS1800

None

0~15

None

NO, YES

None

1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12

None

0~1, 255

None

0~23, 255

None

0~53, 255

None

0~15

None

NO, YES

None

1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12

None

0~1, 255

None

0~23, 255

None

0~53, 255

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

OFF, ON

None

NO, YES

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

OFF, ON

None

NORTPCOMP, RTPCOMP

None

NORTPCOMP, RTPCOMP

None

1214~2001, 2005~3783, 3786~4783, 4785~65000

None

0~65535

None

Administrators, Operators, Users, Guests, Customs

None

0~99

None

0~64

None

300~1000

ms

0~9 Characters

None

1~8 characters

None

TCH:480~122400, step:480; SDCCH:470~119850,


step:470

ms

1~30

dB

1~30

dB

1~30

dB

1~30

dB

0.5~4, step:0.5

0.5~4, step:0.5

1~255

None

0~240

ms

1~64

None

0~63

dB

1~64

None

1~64

None

1~10

None

1~30

dB

1~30

dB

1~30

dB

1~30

dB

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

0~15

None

1~100

None

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

1~30

dB

1~30

dB

1~100

None

0~3

None

0~7

None

0~7

None

TCH:480~9600, step:480; SDCCH:470~9400,


step:470

ms

0~7

None

0~63

dB

0~70

None

0~70

None

0~70

None

0~10

None

TCH:0~9120, step:480; SDCCH:0~8930, step:470

ms

0~63

dB

0~63

dB

TCH:0~9120, step:480; SDCCH:0~8930, step:470

ms

0~10

None

TCH:0~9120, step:480; SDCCH:0~8930, step:470

ms

TCH:0~9120, step:480; SDCCH:0~8930, step:470

ms

0~100

None

0~100

None

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~63

dB

0~63

dB

NO, YES

None

1~64

None

NO, YES

None

0~255

GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus

None

NO, YES

None

1~6

None

10~3500

mA

10~3500

mA

10~3500

mA

10~3500

mA

10~3500

mA

10~3500

mA

0~2047

None

0~2047

None

BYNAME, BYID

None

BYNAME, BYID

None

1~64 characters

None

1~64 characters

None

0~15

None

CS1, CS2, CS3, CS4

None

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7,


MCS8, MCS9

None

10~70

None

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, UAS7, UAS8,


None
UAS9, UAS10, UAS11

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, UAS7, UAS8,


None
UAS9, UAS10, UAS11, UNFIXED

0~5000

ms

CS1, CS2, CS3, CS4, UNFIXED

None

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7,


MCS8, MCS9, UNFIXED

None

0~70

None

0~63

dB

10~255

0~96

None

NO, YES

None

0~2047

None

512~1535

None

1~16

0.1~1, step:0.1

None

1~16

NO, YES

None

0~300

ms

0~64

per cent

0~64

per cent

0~64

per cent

0~64

per cent

0~64

per cent

0~64

per cent

FORBID, PERMIT

None

BYTMSI, BYIMSI, BYMSISDN, BYIMEI

None

NOTSUPPORT, SUPPORT

None

1~32 characters

None

1~32 characters

None

HOUR 0~23
MINUTE 0~59

None

HOUR 0~23
MINUTE 0~59

None

-99~99

degree Celsius

0~8

None

0~255

0~63

dB

NO, YES

None

1~255

1~63

dB

FDD, TDD

None

2 characters

None

0~190, 255

None

No_Priority, Public_Network_First, VGCS_First

None

0~190

None

50~95

per cent

NO, YES

None

NONE, LEVEL4, LEVEL3, LEVEL2, LEVEL1, LEVEL0,


LEVELB, LEVELA

None

50~95

per cent

DISABLE, ENABLE

None

DISABLE, ENABLE

None

DISABLE, ENABLE

None

DISABLE, ENABLE

None

2~4094

None

2~4094

None

2~4094

None

2~4094

None

2~4094

None

2~4094

None

0~7

None

0~7

None

NO, YES

None

Full_rate_Ver1, Full_rate_Ver2, Full_rate_Ver3,


Half_rate_Ver1, Half_rate_Ver2, Half_rate_Ver3,
Full_rate_Ver5

None

CLOSE, OPEN

None

1~9 characters

1~9 characters

CLOSE, OPEN

None

1~9 characters

1~9 characters

NO, YES

None

0~12

None

1~30

None

14,
15,
16,
18,
20,
22,
24,
26,
28,
30,
33,
36,
88

None

18,
20,
22,
24,
26,
28,
30,
32,
35,
38,
41,
45,
88

None

0~12

None

0~999

None

4000~33000

ms

3000~34000

ms

3000~34000

ms

0~1000

1~30

0~60

0~1000

INACTIVE, ACTIVE

None

CLOSE, OPEN

None

NOLIMIT, LIMIT

None

East_Longitude, West_Longitude

None

INACTIVE, ACTIVE

None

NO, YES

None

DENY, ALLOW

None

SUN, MON, TUE, WED, THU, FRI, SAT

None

M3UA_ASP, M3UA_IPSP

None

0~24

NO, YES

None

5~1275, step:5

min

0~24

NO, YES

None

Active, Standby

None

GSM_AND_UMTS, UMTS, GSM

None

GO

None

E1_UNBA, E1_BA, T1, E1

None

E1, T1

None

1~127

None

30~300

60~300

30~60000

GMT-1200(GMT-12:00), GMT-1100(GMT-11:00), GMT1000(GMT-10:00), GMT-0930(GMT-09:30), GMT0900(GMT-09:00), GMT-0800(GMT-08:00), GMT0700(GMT-07:00), GMT-0600(GMT-06:00), GMT0500(GMT-05:00), GMT-0430(GMT-04:30), GMT0400(GMT-04:00), GMT-0330(GMT-03:30), GMT0300(GMT-03:00), GMT-0200(GMT-02:00), GMT0100(GMT-01:00), GMT(GMT),
GMT+0100(GMT+01:00), GMT+0200(GMT+02:00),
GMT+0300(GMT+03:00), GMT+0330(GMT+03:30),
GMT+0400(GMT+04:00), GMT+0430(GMT+04:30),
GMT+0500(GMT+05:00), GMT+0530(GMT+05:30),
GMT+0545(GMT+05:45), GMT+0600(GMT+06:00),
GMT+0630(GMT+06:30), GMT+0700(GMT+07:00),
GMT+0800(GMT+08:00), GMT+0845(GMT+08:45),
GMT+0900(GMT+09:00), GMT+0930(GMT+09:30),
GMT+1000(GMT+10:00), GMT+1030(GMT+10:30),
GMT+1100(GMT+11:00), GMT+1130(GMT+11:30),
GMT+1200(GMT+12:00), GMT+1245(GMT+12:45),
GMT+1300(GMT+13:00), GMT+1400(GMT+14:00)

None

Default Value

Recommended Value

50

50

50

50

40

40

YES

YES

30

30

60

60

IDLETSALLOC_0

IDLETSALLOC_0

CLOSE

CLOSE

90

90

NO

NO

15

15

GSM_PHASE_2

It is recommended that the value of


this parameter is the same as that
for "A Interface Tag".

40

40

100

100

8BIT

8BIT

NO

NO

None

None

Usubcell

Usubcell

None

None

NEUTRAL

NEUTRAL

120

120

YES

YES

Enable

Enable

CLOSE

CLOSE

FLEX

FLEX

4_75KBIT/S-1&5_15KBIT/S0&5_90KBIT/S-1&6_70KBIT/S0&7_40KBIT/S-1&7_95KBIT/S0&10_2KBIT/S-0&12_2KBIT/S-1

4_75KBIT/S-1&5_15KBIT/S0&5_90KBIT/S-1&6_70KBIT/S0&7_40KBIT/S-1&7_95KBIT/S0&10_2KBIT/S-0&12_2KBIT/S-1

4_75KBIT/S-1&5_15KBIT/S0&5_90KBIT/S-1&6_70KBIT/S0&7_40KBIT/S-1&7_95KBIT/S-0

4_75KBIT/S-1&5_15KBIT/S0&5_90KBIT/S-1&6_70KBIT/S0&7_40KBIT/S-1&7_95KBIT/S-0

6_60KBIT/S-1&8_85KBIT/S1&12_65KBIT/S-1

6_60KBIT/S-1&8_85KBIT/S1&12_65KBIT/S-1

NO

NO

10

10

180

180

2800

2800

1800

1800

280

280

NO

NO

None

None

None

None

None

BYAUTO

None

OFF

OFF

None

None

UNLOCK

UNLOCK

Unlock

Unlock

Unlock

Unlock

None

None

10

10

OFF

OFF

None

None

None

None

None

None

None

None

400

400

20

20

-50

-50

CLOSE

CLOSE

20

20

64_Times

64_Times

48

48

None

None

None

None

52_Times

52_Times

32

32

None

None

None

None

None

None

None

None

None

None

None

None

None

None

15

15

None

None

None

None

NO

NO

YES

YES

YES

YES

YES

YES

YES

YES

NO

NO

ABIS

ABIS

10

10

10

10

10

10

NO

NO

-18

-18

-4

-4

-23

-23

FIXEDGAIN

FIXEDGAIN

CLOSE

CLOSE

None

None

ALLOW

ALLOW

OFF

OFF

100

100

NOTALLOW

NOTALLOW

100

100

None

ALLCIC

ALLCIC

ALLCIC

30

30

30

30

30

30

30

30

30

30

30

30

None

None

YES

YES

None

None

None

None

10

10

100

100

150

150

None

None

NO

NO

all

all

None

None

40

40

None

None

None

None

None

None

DISABLED

DISABLED

DISABLED

DISABLED

DISABLED

DISABLED

DISABLED

DISABLED

DISABLED

DISABLED

DISABLED

DISABLED

16

16

ON

ON

NO

NO

33

33

25

25

NO

NO

20

20

100

100

75

75

108

108

NO

NO

15

15

YES

YES

ON

ON

55

55

NO

NO

30

30

18

18

CLOSE

CLOSE

12

12

None

None

None

None

None

None

None

None

MODE0

MODE0

-13

-13

-48

-48

CLOSE

CLOSE

360

None

NOPOWER

NOPOWER

OFF

OFF

NO

NO

None

None

None

None

None

None

NULL

NULL

None

None

None

None

None

None

20

20

1024

1024

256

256

20

20

10

10

20

20

CLOSE

CLOSE

384

384

None

PRIMARY

None

PRIMARY

PRIMARY

50

50

100

100

100

100

None

None

None

None

None

None

None

None

None

None

OFF

OFF

DISABLE

DISABLE

35

35

None

None

None

None

None

None

None

None

None

None

None

None

30

30

10000

10000

30

30

60

60

30

30

60

60

30

30

30

30

20

20

NO

NO

10

10

YES

YES

Open

Open

85

85

None

None

90

90

None

None

None

None

None

None

None

None

None

None

TDM

TDM

None

None

None

None

YES

YES

None

60

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO_V

NO_V

NO_V

NO_V

NO_V

NO_V

None

ENABLE

YES

None

YES

YES

YES

YES

NO

NO

ENABLED

ENABLED

None

None

ON

None

None

None

None

AU4

GSM_PHASE_2

GSM_PHASE_2 is recommended in
common scenarios. If AMR services,
inter-RAT handover, eMLPP, or A
over IP mode needs to be
supported, "GSM_PHASE_2Plus" is
recommended.

HIGH

None

LOW

LOW

None

None

None

None

None

None

None

None

OFF

None

OFF

None

None

None

None

None

55

55

ALLTLLI

ALLTLLI

None

None

None

None

None

None

BYTRX

BYTRX

BYCOVER

BYCOVER

20

20

None

None

None

None

Battery1Temp

For EPS4815 boards, the value of


this parameter is always
"Battery1Temp".

Battery1Temp

Battery1Temp

50

50

NO

NO

50

50

NO_BAT

NO_BAT

58000

58000

36

36

None

None

None

None

None

None

None

None

None

None

None

None

80

80

60

60

14

14

None

None

15

If "Power System Type" is "APM30",


the recommended value is "7". For
other Power System Type, the
recommended value is "15".

565

565

NO

NO

None

None

NO

NO

YES

YES

None

None

30

30

ALL

ALL

None

None

ENABLE

None

None

900

None

ENABLE

None

10

10

None

None

None

None

None

None

1000

1000

None

NO

None

None

NULL

NULL

NULL

NULL

YES

YES

69

69

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

Cell name

None

60

60

INCREMENTAL

None

None

None

NO

NO

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

UNCONDITIONALSTART

UNCONDITIONALSTART

None

None

YES

YES

NO

NO

None

None

None

None

YES

YES

YES

YES

NO

NO

65535

65535

65535

65535

65535

65535

65535

65535

65535

65535

65535

65535

65535

65535

65535

65535

None

None

None

None

None

None

None

None

None

None

None

None

None

None

10

10

YES

YES

2_M_PERIOD

2_M_PERIOD

NEITHERSTART

NEITHERSTART

NONSUPPORT

NONSUPPORT

YES

YES

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

YES

YES

None

None

LOGICIP

LOGICIP

None

None

None

None

CLOSE

CLOSE

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

UNCONDITIONALSTART

UNCONDITIONALSTART

None

None

BTS_Preprocessing

BTS_Preprocessing

None

None

None

None

None

None

ON

ON

NO

NO

16

16

OFF

OFF

None

None

None

None

None

None

None

None

None

None

None

None

NO_BAT

NO_BAT

60

60

NO

NO

None

None

None

None

1000

1000

None

None

20

20

15

15

120

120

None

None

25

25

80

80

None

None

C31STANDARD

C31STANDARD

None

None

None

None

None

None

YES

If this parameter is set to NO, the


average call drop rate decreases.
This setting is applicable in suburbs
or urban areas with poor coverage.
Call reestablishment, however, may
take a long time. Therefore, the
subscriber may hang up the phone
before the call is re-established.
Generally, the recommended value
is YES.

None

None

YES

YES

None

None

GSM900

GSM900

NULL

NULL

None

None

None

None

NO

The CBA function applies to special


scenarios. If this parameter is set to
YES and "Cell Bar Qualify" is set to
no, only handovers are allowed in a
cell, and direct access of an MS is
not allowed. This condition applies
to a dual-network coverage cell. For
a common cell, this parameter
should be set to NO.

None

None

None

None

30

30

None

None

15

15

NO

NO

4500

4500

86

None

None

None

15

15

80

80

46

46

1000

1000

90

90

None

None

None

None

None

None

None

None

Permit

Permit

OUTDOOR_CELL

OUTDOOR_CELL

283

283

565

565

268

268

535

535

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO

NO

80

80

None

None

None

None

None

None

None

None

255

255

30

30

YES

YES

430

430

2G

2G

30

30

COMMON

COMMON

NO

NO

500

500

-100

-100

800

800

-200

-200

NO

NO

20

20

80

80

None

None

NULL

NULL

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

80

80

80

80

None

None

None

None

None

None

90

90

90

90

90

90

QUICK_HO_NCELL_TYPE_A

QUICK_HO_NCELL_TYPE_A

None

None

CAPABILITY

CAPABILITY

OFF

OFF

100

100

None

None

YES

YES

NO

NO

10

10

YES

YES

MODE2

MODE2

MODE2

MODE2

None

None

None

None

10

10

10

10

NO

NO

NO

NO

CRC32

CRC32

None

None

None

None

None

None

None

None

None

None

None

None

None

None

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

SYSTEMOPT

SYSTEMOPT

NO

NO

OFF

OFF

100

100

200

200

1000

1000

TCHFR

TCHFR

None

None

None

None

None

None

None

None

OFF

OFF

80

80

YES

YES

YES

YES

NOTSENDING

NOTSENDING

NOTSENDING

NOTSENDING

YES

YES

YES

YES

None

None

22

22

None

None

None

None

UNSUPPORT

None

NO

NO

None

ERR_PFM_5E6

None

None

PTP

PTP

GCUa

None

None

None

255

255

None

None

255

255

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

30

30

None

None

None

None

None

None

None

None

NONE

NONE

None

None

None

None

None

None

None

None

None

None

YES

YES

None

None

INACTIVE

INACTIVE

None

None

45

45

L0_FORBID-0&L1_FORBID0&L2_FORBID-0&L3_FORBID0&L4_FORBID-0&L5_FORBID0&L6_FORBID-0&L7_FORBID0&L8_FORBID-0&L9_FORBID-0

L0_FORBID-0&L1_FORBID0&L2_FORBID-0&L3_FORBID0&L4_FORBID-0&L5_FORBID0&L6_FORBID-0&L7_FORBID0&L8_FORBID-0&L9_FORBID-0

None

None

100

100

NO

NO

None

None

15

IP/HDLC:15

15

IP/HDLC:15

15

IP/HDLC:15

15

IP/HDLC:15

25

25

25

25

25

IP/HDLC:25

25

IP/HDLC:25

25

IP/HDLC:25

25

IP/HDLC:25

50

50

50

50

NO

NO

None

None

NO

NO

None

None

None

None

NO

NO

None

None

NO

NO

None

None

NOTSUPPORT

NOTSUPPORT

6dB

6dB

None

None

None

None

10

10

255

255

UNAVAILABLE

UNAVAILABLE

None

None

OFF

OFF

RESINSUFF,UMABNORM,TRAFFREJEC RESINSUFF,UMABNORM,TRAFFREJEC
T,MSCREL
T,MSCREL

100

100

None

When the interface type is Abis,


transmission type is IP, the
parameter is AF43; When the
interface type is A, Ater or Iur-g, the
parameter is AF43.

None

When the interface type is Abis and


transmission type is HDLC, the
parameter is 1.

100

100

OFF

OFF

OFF

OFF

OFF

OFF

None

None

ABNORMREC

ABNORMREC

None

ON

OFF

OFF

90

90

CALL

CALL

50

50

OFF

OFF

None

When the interface type is Abis,


transmission type is IP, the
parameter is EF; When the interface
type is A, Ater or Iur-g, the
parameter is EF.

None

When the interface type is Abis and


transmission type is HDLC, the
parameter is 1.

50

50

None

ON

45000

45000

30000

30000

1300

1300

500

500

8200

8200

100

100

5000

5000

1500

1500

100

100

95

95

95

85

None

None

4BURST

4BURST

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

OFF

NO

NO

None

None

30

None

None

None

NT14_5K-0&NT12K-1&NT6K1&T14_4K-0&T9_6K-1&T4_8K1&T2_4K-1&T1_2K-0&T600_BITS0&T1200_75-0

NT14_5K-0&NT12K-1&NT6K1&T14_4K-0&T9_6K-1&T4_8K1&T2_4K-1&T1_2K-0&T600_BITS0&T1200_75-0

None

None

NOLIMIT

NOLIMIT

None

None

None

None

None

If the coverage area in the underlaid


subcell is large and tight frequency
reuse is used in the overlaid subcell,
the recommended value is Inner.
If the coverage areas in the overlaid
and underlaid subcells are similar
and tight frequency reuse is used on
the BCCH, the recommended value
is Extra.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

If "Power System Type" is


"SC48200", the recommended value
is "470". For Power System Type, the
recommended value is "450".

580

580

450

450

580

580

1000

1000

None

None

None

None

INACTIVE

INACTIVE

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

OFF

None

None

None

None

None

None

None

None

None

None

None

None

None

None

YES

YES

None

DEFAULTPORT

None

None

None

None

DISABLE

DISABLE

NO

NO

None

None

None

None

None

None

None

None

NO

NO

YES

YES

NO

NO

None

None

N0

N0

14

14

14

14

16

16

16

16

None

None

UNSUPPORT

None

20

The recommended value is 20 when


HUAWEI I Handover is used;
The recommended value is 15 when
HUAWEI II Handover is used.

16

16

16

16

18

18

18

18

15

15

35

35

40

40

90

90

The recommended value is 8 when


DTX is disabled.
The recommended value is 14 when
DTX is enabled.

60

60

100

100

10

10

55

55

60

60

55

55

20

20

20

20

55

55

45

45

28

28

140

140

12

12

17

17

25

25

23

23

31

31

63

63

12

12

18

18

None

None

None

None

None

None

CS2

CS2

MCS6

MCS6

DAS6

DAS6

UNFIXED

UNFIXED

UNFIXED

UNFIXED

UNFIXED

UNFIXED

YES

YES

NO

NO

2400

2400

10

10

OPEN

None

30

30

None

None

None

None

None

None

None

None

None

None

None

None

None

None

72

72

60

IP/HDLC:60

60

IP/HDLC:60

60

IP/HDLC:60

60

IP/HDLC:60

80

80

80

80

10

10

YES

YES

INACTIVE

INACTIVE

None

None

None

None

48

48

None

None

180

180

None

None

None

None

None

None

None

None

None

None

15

15

NO

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

85

85

YES

YES

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

OFF

OFF

FULL

FULL

None

None

None

None

None

None

None

None

20

20

20

20

None

None

None

None

None

None

20

20

LEVEL0

LEVEL0

YES

YES

NOTSUPPORT

NOTSUPPORT

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

30

30

YES

1. For a 900/1800 MHz Co-BCCH cell,


it is recommended that this
parameter be set to Yes.
2.
For a 1800 MHz cell in the dualband network, it is recommended
that this parameter be set to Yes.
For other cells in the dual-band
network, it is recommended that
this parameter be set to No.
3. When the A5/4-7
encryption algorithm is used, it is
recommended that this parameter
be set to Yes.
4. When frequencies of the
extended frequency band exist on a
900 MHz cell, it is recommended
that this parameter be set to Yes.

2147483646

2147483646

None

None

None

None

None

None

None

None

None

None

10

10

NO

None

None

None

YES

YES

NO

None

16

16

None

None

15

15

OFF

OFF

None

ERR_PFM_1E5

None

None

NO

NO

NO

NO

Priority4

Priority4

None

None

None

None

None

None

None

None

NO

NO

None

None

A5/0-1&A5/1-0&A5/2-0&A5/30&A5/4-0&A5/5-0&A5/6-0&A5/7-0

A5/0-1&A5/1-0&A5/2-0&A5/30&A5/4-0&A5/5-0&A5/6-0&A5/7-0

AUTO

AUTO

None

None

NO

NO

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

ENABLED

ENABLED

70

70

OFF

OFF

ON

ON

20

20

ON

ON

ON

ON

80

80

YES

None

None

None

None

None

63

63

OFF

OFF

None

None

NO

NO

O5E4_R1E4

O5E4_R1E4

OFF

OFF

None

None

None

None

None

None

2147483646

2147483646

3000

3000

CLOSE

CLOSE

None

None

None

None

None

None

None

None

None

ONE_BY_ONE

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

0.02

None

0.004

None

CURRENT

None

100

None

None

0.02

None

0.004

None

CURRENT

None

100

None

None

0.02

None

0.004

None

CURRENT

None

100

None

None

0.02

None

0.004

None

CURRENT

None

100

None

None

NoExclusive

NoExclusive

None

25

30

30

30

30

None

None

None

None

None

None

None

None

None

None

None

None

CLOSE

CLOSE

YES

YES

EM0

EM0

60sec

60sec

TYPE1

TYPE1

Normal_cell

Normal_cell

SEND

SEND

NO

NO

NO

NO

None

None

OFF

None

30

30

None

None

None

None

None

None

None

None

None

None

SOFTWARE_CONTROL

SOFTWARE_CONTROL

None

None

NO

NO

OFF

OFF

CLOSE

CLOSE

None

None

55

75

None

None

None

None

None

None

None

None

None

None

85

85

16bit

16bit

16bit

16bit

ON

None

535

535

None

None

None

None

None

None

None

None

10

10

RSCP

RSCP

10

10

None

None

NO

For the double-transceiver BTS and


NGBTS, the default value is NO; for
other BTS, this parameter is invalid.

16

16

32

32

64

64

128

128

NO_FH

NO_FH

None

None

None

None

None

None

None

None

csv

csv

None

None

NO

NO

INACTIVE

INACTIVE

80

80

ENABLE

ENABLE

900

900

900

900

FIX_16K_ABIS

FIX_16K_ABIS

OFF

When tight frequency reuse is used,


the recommended value is ON.

OFF

OFF

4500

4500

1000

1000

ON

ON

None

None

None

ON

ON

ON

ON

ON

ON

ON

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

OPEN

OPEN

None

None

None

None

None

None

None

none

None

None

None

None

None

None

None

None

OPEN

OPEN

15

15

Close

Close

NO

NO

YES

YES

None

None

None

None

None

None

None

None

None

None

256

None

None

None

YES

YES

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO

NO

36671

36671

None

None

25

25

None

None

LOOSE

LOOSE

None

None

MaximumMeanValue

MaximumMeanValue

YES

YES

Shall_Use

Shall_Use

None

None

None

None

None

None

None

None

TXT

TXT

None

None

None

None

None

None

20

20

10

10

20

20

15

15

110

110

10

10

A0

A0

12

12

None

None

40

40

None

ON

None

None

NO

NO

OFF

OFF

DEG

DEG

YES

YES

YES

YES

None

None

20

20

NO

NO

NO

None

2dB

2dB

NONGPRS

NONGPRS

DB110

DB110

10sec

10sec

10db

10db

GPS

GPS

10

10

NO

NO

None

None

None

None

None

None

None

None

None

None

None

None

None

LAC_CI

80

80

10

10

SUPPORT

SUPPORT

None

None

None

None

255.255.255.255

255.255.255.255

NO

NO

20

20

10

10

NO

NO

NO

NO

None

1000(application type is M3UA),


5000(application type is BBAP)

None

None

65535

None

65535

None

DCS1800

DCS1800

NO

NO

NO

NO

YES

YES

YES

YES

None

None

UNSUPPORT

None

SysOpt

SysOpt

NO

NO

10

10

None

None

None

None

HOALGORITHM1

HOALGORITHM1

NO

NO

50

50

35

35

None

None

68

68

32

32

Pre_2G_CellThres

Pre_2G_CellThres

None

None

None

None

None

None

YES

YES

25

25

OFF

OFF

None

None

NO_FH

NO_FH

63

63

15

15

50

50

YES

YES

10

10

10

10

SINGLEHOST

SINGLEHOST

SINGLEHOST

SINGLEHOST

25

25

50

50

NONE

NONE

None

None

None

None

NO

NO

440

440

NO

NO

YES

YES

YES

YES

Shall_Use

Shall_Use

None

None

OFF

OFF

None

None

None

None

40

40

None

None

ENABLE

ENABLE

OPEN

None

80

None

10

None

1000

If "Power System Type" is


"SC48200", the recommended value
is "900". For other types of Power
System, the recommended value is
"1000".

800

800

If "Power System Type" is


"SC48200", the recommended value
is "100". For other types of Power
System, the recommended value is
"0".

100

100

15

15

720

720

None

None

None

None

None

None

90

90

10

10

NO

NO

NO

Set this parameter to YES for the


neighboring cell with co-channel
interference and the neighboring
cell that may cause interference; set
this parameter to NO for other
neighboring cells.

OFF

OFF

OFF

OFF

10

10

13

13

10

10

YES

YES

20

20

NO

NO

15

It is recommended that you set the


path loss offset of layer 1
neighboring cells of the serving cell
to 15 dB and that of other
neighboring cells to 25 dB.

110

110

NO

NO

OFF

OFF

20

20

UNDER

UNDER

NO

NO

NO

NO

ENABLE

For SingleRAN BTS, the


recommended value is "ENABLE".
For other types of BTS, the
recommended value is "DISABLE".

64

64

22

22

20

20

18

18

None

None

None

None

None

None

84

84

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

YES

YES

None

None

Positive

Positive

YES

YES

None

None

5000

5000

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

10

10

None

None

None

None

10000

10000

360

360

None

None

NO

NO

10

10

CELLCAPCLASS

CELLCAPCLASS

OPEN

None

25

25

12

12

None

None

NO

NO

YES

YES

None

None

None

None

NO

NO

10

10

90

90

None

None

None

None

None

None

Degree

Degree

NO

NO

None

None

None

None

None

None

None

None

None

60

67

67

INTBANII

INTBANII

68

In densely populated urban areas,


the recommended value is 68; in the
suburbs, the recommended value is
72.

15

15

YES

YES

YES

YES

110

110

105

105

98

98

92

92

87

87

85

85

20

20

NO

NO

80

80

NO

NO

NO

NO

20

20

49

49

60

60

91

91

10

10

NO

NO

OFF

OFF

72

72

30

30

None

None

10000

10000

YES

YES

NO

In the hot-spot areas, densely


populated urban areas, urban areas,
suburbs, and rural areas, the
recommended value is YES; in the
high-speed circumstances, the
recommended value is NO.

10000

10000

None

None

25

25

10

10

30

30

None

None

None

None

30

None

None

None

NO

NO

255.255.255.255

255.255.255.255

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

10

10

UDP/IP_HC

UDP/IP_HC

UDP/IP_HC

UDP/IP_HC

None

None

None

None

None

None

IP_OVER_FE/GE

IP_OVER_FE/GE

None

None

NO

NO

None

NO

NO

NO

None

None

None

None

NO

NO

NO

NO

YES

YES

None

None

YES

YES

NO

NO

None

None

None

None

NO

NO

None

None

None

None

NO

NO

None

None

NO

NO

NO

NO

NO

NO

None

None

NO

NO

NO

NO

NOT_CONFIG

NOT_CONFIG

None

None

None

None

None

None

65535

65535

None

None

None

None

NONE

NONE

CONVERT0

CONVERT0

10

10

Normal_cell

Normal_cell

None

OFF

Character_String

Character_String

None

SBS 155

None

SBS 155

None

16byte

None

OFF

Character_String

Character_String

None

SBS 155

None

SBS 155

None

16byte

None

OFF

None

None

None

None

None

None

None

None

None

SPACE

None

None

None

None

DENY

When the disorder phenomenon is


severe in the IP network, the
recommended value is ALLOW;
when there is no or little disordered
packets, you are recommended to
set this parameter to DENY to avoid
extra transmission delay.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

25

25

20

20

30

30

CSFHHO

CSFHHO

PSDOWN

PSDOWN

AMRC

AMRC

None

None

None

ON

None

None

None

None

YES

None

YES

YES

None

None

None

None

None

None

None

None

None

None

10

10

90

90

70

70

None

None

DIFFERENCE

DIFFERENCE

64K

64K

None

None

10

None

None

None

35

35

45

45

None

None

None

None

M3UA_MASTER_MOD

M3UA_MASTER_MOD

B1111

B1111

B1111

B1111

80

80

RANDOMALG

RANDOMALG

100

100

NO

NO

NO

NO

NO

NO

NO

NO

10

10

63

63

10

10

25

25

NO

NO

PERMIT

PERMIT

40

40

60

60

85

85

YES

YES

DYNPDCHASIDLE

DYNPDCHASIDLE

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

ON

OFF

None

None

None

None

NORMMODE

NORMMODE

90

95

90

80

None

None

None

None

None

None

80

85

80

70

ON

ON

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

ON

None

None

80

80

None

None

None

None

None

None

None

None

180

180

NO

NO

NO

NO

ON

ON

OFF

You are advised to disable this


function in the co-BCCH cell with the
inter-site distance not more than
1500m.

NO

For EPS4815 boards, the value of


this parameter is set to "NO".

NO

NO

None

None

None

None

None

None

None

None

None

None

None

None

IR

IR

DISABLE

DISABLE

None

If "Power System Type" is


"SC48200", the recommended value
is "475". For other Power System
Type of APMU boards, the
recommended value is "440".

CSPH

CSPH

None

INCLUDE

HORIZONTAL

None

HORIZONTAL

HORIZONTAL

APPLICATION

APPLICATION

OPTLOG

None

None

OPTLOG

-1

-1

60

60

20

20

30

30

ENABLE

For EPS4815, the recommended


value is "DISABLE". For other types
of APMU boards, the recommended
value is "ENABLE".

2905

2905

None

None

None

10

None

CA_MA

CA_MA

None

None

YES

YES

NO

NO

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

170

170

170

170

170

170

170

170

170

170

170

170

None

None

None

None

None

None

None

None

None

None

255.255.255.255

255.255.255.255

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

4(application type is M3UA),


10(application type is BBAP)

None

None

10

10

1031

1031

100

100

None

None

256

256

None

None

None

None

125

125

None

2(application type is M3UA),


5(application type is BBAP)

30

30

None

None

15C

15C

15C

15C

30

30

7_Times

7_Times

7_Times

7_Times

7_Times

7_Times

7_Times

7_Times

64

64

None

None

62

In Normal cell,the recommended


value is 62;in Double Timeslot
Extension Cell,the recommended
value is 219.

20

20

OFF

OFF

255

255

12

12

32

32

16

16

None

None

None

None

None

None

If the traffic volume on each


frequency band is even and there is
no special requirements for the
frequency band, the recommended
value is 0; if the traffic volume on
each frequency band is significantly
uneven and a frequency band is
preferred for an MS, the
recommended value is 3; if traffic
volume on each frequency band is
not extremely uneven, the
recommended value is 1 or 2. For
details, see the GSM Rec. 05. 08.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

OFF

OFF

CLASS0

CLASS0

None

None

None

None

None

None

NO

NO

ComMeasReport

ComMeasReport

None

None

None

None

None

None

LONG

LONG

LONG

LONG

15

15

None

None

10

10

170

170

170

170

170

170

170

170

170

170

170

170

170

170

170

170

140

140

140

140

16

16

60

60

10

10

100

100

100

100

100

100

100

100

None

None

None

None

None

None

None

None

None

None

80

80

None

None

None

None

AUTO

AUTO

None

OFF

None

None

None

None

None

None

MODE1

MODE1

MODE1

MODE1

MODE1

MODE1

MODE1

MODE1

MODE1

MODE1

MODE1

MODE1

None

None

None

None

None

None

35

35

10

10

None

None

None

None

None

None

MODE4_1

MODE4_1

None

If "BTS Type" is "BTS3900E_GSM",


the recommended value is "0".

ENABLE

ENABLE

MCPPP

MCPPP

None

None

None

None

YES

YES

Once_ps

Once_ps

OFF

OFF

None

None

1500

1500

OFF

OFF

1800

1800

NO

NO

NORMAL

NORMAL

R98_or_below

R98_or_below

15000

15000

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO

NO

4_Times

4_Times

None

None

MCS5

MCS5

40

40

None

None

10

10

200

200

1000

1000

45

45

None

ON

85

85

None

None

None

None

MET

MET

800

800

1500

If "MTU" is set to a value smaller


than 576, the DHCP procedure may
fail when the BTS tries to retrieve
the IP address, and thus the BTS
cannot work. The recommended
value of this parameter is 1500. Do
not modify it unless in special
scenarios, for example, at the
bottom layer where the number of
MTU is limited.

None

1500

225

225

REPORT6

REPORT6

None

None

DISABLE

None

NO

NO

1000

1000

None

None

None

None

None

None

When the transmission quality is


good, the recommended settings
are as follows: "Ring II Wait Time
Before Switch" = 0; "Ring II Try
Rotating Duration Time" = 60; "Ring
II Rotating Penalty Time" = 0;
"T200" = 12; "T203" = 1; and
"N200" = 3.
When the transmission quality is
bad, the recommended settings are
as follows: "Ring II Wait Time Before
Switch" = 30; "Ring II Try Rotating
Duration Time" = 60; "Ring II
Rotating Penalty Time" = 0; "T200"
= 24; "T203" = 3; and "N200" = 3.

34

34

29

29

OFF

OFF

23

23

20

20

10

10

NO

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO

NO

DISABLE

DISABLE

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO

None

NOTSUPPORT

NOTSUPPORT

NO

None

None

None

None

None

SELECTION0_PERM1&SELECTION1_PERM1&SELECTION2_PERM1&SELECTION3_PERM1&SELECTION4_PERM1&SELECTION5_PERM1&SELECTION6_PERM1&SELECTION7_PERM-1

SELECTION0_PERM1&SELECTION1_PERM1&SELECTION2_PERM1&SELECTION3_PERM1&SELECTION4_PERM1&SELECTION5_PERM1&SELECTION6_PERM1&SELECTION7_PERM-1

60

60

64

64

68

68

72

72

74

74

76

76

80

80

NC0

NC0

YES

YES

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NMOII

NMOII

None

None

None

None

None

None

None

None

43

None

57

None

43

None

57

None

43

None

57

None

43

None

57

None

43

None

57

None

43

None

57

None

NO

NO

30

30

95

95

85

85

14

14

103

103

NO

NO

25

25

None

None

NO

NO

50

50

100

100

ON

ON

0.24sec

0.24sec

2500

2500

2500

2500

PERMIT

PERMIT

500

500

CLOSE

CLOSE

48

48

30

30

None

None

None

None

YES

YES

None

None

None

None

None

None

None

None

None

None

16

16

10

10

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

OFF

OFF

YES

YES

NO

NO

None

OFF

10

10

None

None

64

64

64

64

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

SysOpt

SysOpt

35

35

63

63

L0

L0

None

None

None

None

None

None

None

None

None

None

Step_by_Step

Step_by_Step

None

None

20

20

YES

YES

10000

10000

10000

10000

NO

NO

80

80

15

15

25

25

YES

YES

50

50

None

None

None

None

None

None

None

None

HIGH

HIGH

HIGH

HIGH

HIGH

HIGH

HIGH

HIGH

None

None

None

None

None

None

90

90

YES

YES

None

None

None

None

None

None

NO

NO

NO

NO

CLOSE

CLOSE

15

15

None

None

320

320

320

320

185

185

280

280

280

280

155

155

1500

1500

1500

1500

15

15

580

580

90

90

85

85

80

80

75

75

NO

NO

NO

NO

180

180

255

255

220

220

Pan_1

Pan_1

Pan_2

Pan_2

Pan_20

Pan_20

L0

L0

None

None

None

None

DISABLED

DISABLED

None

None

None

None

79

79

NO

NO

None

QoS

None

None

DB2

DB2

YES

YES

68

In densely populated urban areas,


the recommended value is 68; in the
suburbs, the recommended value is
72.

PDCH

PDCH

None

None

None

None

None

None

None

None

NO

NO

80

80

NO

NO

NO

NO

70

70

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

255.255.255.255

255.255.255.255

None

None

None

None

YES

YES

10

10

30

30

255

255

None

YES

YES

Enable

Enable

Enable

Enable

NO

NO

660

660

660

660

1000

1000

None

None

None

None

YES

YES

None

None

10

10

128

128

None

None

1031

1031

NO

None

128

128

56

56

12_level

12_level

13_level

13_level

14_level

14_level

16_level

16_level

10

10

30

30

None

None

None

None

None

None

60

60

60

67

OPEN

OPEN

50

50

50

62

ON

ON

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

650

650

16

16

Support

Support

None

None

None

None

None

None

None

None

None

None

None

None

16

16

None

None

CLOSE

None

None

None

None

None

BCCHNorm

BCCHNorm

None

None

125

125

CLOSE

None

CLOSE

None

CLOSE

None

CLOSE

None

CLOSE

None

CLOSE

None

100

100

POWER_48_24

POWER_48_24

220VAC

220VAC

DEFAULT

None

10

10

None

None

None

None

None

None

None

None

Disable

Disable

NO

NO

NOT_ALLOWED

NOT_ALLOWED

OFF

OFF

60

60

NO

NO

NO

NO

60

60

60

72

50

50

50

65

ON

ON

None

None

Prior-1

Prior-1

80

80

None

None

None

None

None

None

None

None

None

None

None

None

ITUT

ITUT

Q933

Q933

15

15

300

300

None

ALL

None

None

None

ALL

OFF

OFF

OFF

When "Mode Control" is set to


"Common User Mode", the
recommended value is OFF; when
"Mode Control" is set to "Specified
User Mode", the recommended
value is ON.

ON

ON

OFF

When "Mode Control" is set to


"Common User Mode", the
recommended value is OFF; when
"Mode Control" is set to "Specified
User Mode", the recommended
value is ON.

ON

ON

100

100

100

100

NO

NO

None

When the interface type is Abis, the


parameter is AF43.

None

When the interface type is Abis and


transmission type is HDLC, the
parameter is 1.

NO

NO

None

When the interface type is Abis,


transmission type is IP, the
parameter is AF33.

None

When the interface type is Abis and


transmission type is HDLC, the
parameter is 2.

25

25

None

None

-109

-109

-109

-109

ON

ON

500

500

1000

1000

YES

YES

YES

YES

YES

For "Power System Type" is "APM30"


or "EPS4815", the recommended
value is "NO". For other types of
Power System, the recommended
value is "YES".

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

35

35

None

None

None

None

None

None

BOOL

BOOL

None

None

None

None

None

None

None

None

None

None

None

E1_CRC4_MULTI_FRAME

None

None

None

None

None

None

None

None

None

None

None

None

500

500

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO

NO

NO

NO

PWR3

PWR3

YES

YES

ALLPwrLoc

ALLPwrLoc

None

None

YES

YES

Default

Default

OFF

OFF

OFF

OFF

OFF

OFF

None

None

None

None

None

None

None

None

None

None

Use_Qsearch_I

Use_Qsearch_I

NO

Set this parameter to YES only in


special scenarios such as highways.

15

15

15

15

NO

NO

15

15

15

15

NO

NO

NONE

NONE

NO

NO

NO

NO

AU0-0&AU1-0&AU2-0&AU3-0&AU4- AU0-0&AU1-0&AU2-0&AU3-0&AU40&AU5-0&AU6-0&AU7-0
0&AU5-0&AU6-0&AU7-0

NO

NO

INSIDE_50AH

INSIDE_50AH

015C

015C

INSIDE_BATTERY

INSIDE_BATTERY

AU0-0&AU1-0&AU2-0&AU3-0&AU4- AU0-0&AU1-0&AU2-0&AU3-0&AU40&AU5-0&AU6-0&AU7-0
0&AU5-0&AU6-0&AU7-0

NO

NO

INSIDE_50AH

INSIDE_50AH

015C

015C

INSIDE_BATTERY

INSIDE_BATTERY

AU0-0&AU1-0&AU2-0&AU3-0&AU4- AU0-0&AU1-0&AU2-0&AU3-0&AU40&AU5-0&AU6-0&AU7-0
0&AU5-0&AU6-0&AU7-0

NO

NO

INSIDE_50AH

INSIDE_50AH

015C

015C

INSIDE_BATTERY

INSIDE_BATTERY

None

None

None

None

None

None

None

-109

-109

16

16

5000

5000

-109

-109

YES

YES

225

225

2dB

2dB

100M

100M

ALG1

ALG1

DISABLE

DISABLE

None

None

None

REC_ALL

None

None

None

None

None

None

NONE

NONE

96

96

YES

YES

Diff_Band

Diff_Band

50

50

40

40

30

30

YES

YES

NO

NO

30

30

60

60

NO

NO

None

None

10

10

None

None

None

None

None

OFF

None

OFF

None

NO

NO

None

None

None

None

600

None

REHOSTDELAY

REHOSTDELAY

None

NO

None

None

NO

NO

OFF

OFF

None

None

None

None

NONE

NONE

None

None

None

None

None

None

None

None

NO

NO

NO

NO

NO

NO

YES

YES

10

10

NO

NO

None

None

None

None

10

10

None

None

YES

YES

NO

None

None

None

30

30

10

10

None

NO

NO

GPS

GPS

NO

NO

None

None

52_Times

52_Times

STANDALONETC

STANDALONETC

None

None

255

255

None

None

None

None

None

None

None

None

None

None

DISABLE

DISABLE

15.36sec

15.36sec

0.96sec

0.96sec

20

20

NO

NO

None

None

None

None

None

None

30

30

None

None

None

None

MINUS_2db

MINUS_2db

None

None

None

None

None

None

None

None

None

None

None

None

68

Set this parameter to about 68 in


densely populated urban areas and
about 72 in suburban areas.

None

None

None

None

OFF

OFF

3000

3000

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

4294967295

4294967295

ON

ON

None

None

None

None

None

None

12

12

25

25

1000

1000

3000

3000

1000

1000

DISABLE

DISABLE

30

30

None

None

None

None

None

None

None

None

NO

In dual-band networking mode for


densely populated urban areas, the
level drops rapidly due to multiple
barriers. The propagation loss of the
1800 MHz frequency band is greater
than the propagation loss of the 900
MHz frequency band. Considering
the preceding factors, you can set
this parameter to YES for the
DCS1800 cell. Under normal
conditions, set this parameter to No.

60

60

42

42

41

41

40

40

50

50

49

49

48

48

47

47

46

46

45

45

44

44

43

43

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

OFF

OFF

None

None

None

None

None

None

NO

NO

NO

NO

None

None

None

None

BYNAME

BYNAME

50

50

None

None

32

32

None

None

None

None

None

None

None

None

None

None

None

None

None

None

ADD0dB

ADD0dB

38

38

None

None

None

None

None

ENGLISH

None

None

None

None

None

BYCELLID

None

None

None

None

None

None

None

None

None

None

None

None

None

0.000001

0.000001

None

None

None

None

OFF

OFF

10

10

55

55

55

55

YES

YES

None

DISABLE

OFF

OFF

ENABLE

ENABLE

40

40

30

30

48

48

None

None

53

53

None

None

None

None

None

If "Power System Type" is


"SC48200", the recommended value
is "460". Otherwise, the
recommended value is "430".

YES

YES

None

None

YES

YES

NO

NO

NO

NO

NO

NO

YES

YES

NoPriority

NoPriority

NoPriority

NoPriority

None

None

NO

NO

YES

YES

YES

YES

None

None

UNSUPPORT

None

None

None

None

None

None

None

None

None

SEPARATE

SEPARATE

TDM

TDM

None

None

None

None

None

None

NO

NO

NO

NO

NO

NO

NO

NO

None

None

1800

1800

None

None

NO

NO

Release 99 onwards

Release 99 onwards

ALLOW

ALLOW

75

75

None

None

NO

NO

None

None

YES

YES

NO

NO

None

None

None

None

None

None

100

100

100

100

None

None

3000

3000

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

255

None

None

None

None

None

None

None

B0000

B0000

300

300

None

None

None

None

None

NOTSUPPORT

OPEN

None

None

None

10

10

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NONE

NONE

DOUBLE_ANTENNA

DOUBLE_ANTENNA

DOUBLE_ANTENNA

DOUBLE_ANTENNA

DOUBLE_ANTENNA

DOUBLE_ANTENNA

DOUBLE_ANTENNA

DOUBLE_ANTENNA

SGL_ANTENNA

SGL_ANTENNA

None

None

None

None

None

None

None

None

None

None

WNF

WNF

L11_FORBID-0&L12_FORBID0&L13_FORBID-0&L14_FORBID0&L15_FORBID-0

L11_FORBID-0&L12_FORBID0&L13_FORBID-0&L14_FORBID0&L15_FORBID-0

None

None

None

None

12

12

YES

YES

YES

YES

YES

YES

NO

NO

PSMODE

PSMODE

PSMODE

PSMODE

FR

FR

None

AUTO

30

30

40

40

NO

NO

NOTSPPRTBC

NOTSPPRTBC

NO

NO

NO

NO

UNSUPPORT

None

UNSUPPORT

None

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

UNSUPPORT

None

NO

NO

None

None

None

None

NOT_SUPPORT

If the version of a GSM base station


is BTS3000V100R009 or later, or if
the version of a multi-mode 3900
series base station is V100R002 or
later, the recommended value of
this parameter is SUPPORT.
Otherwise, the recommended value
of this parameter is NOT_SUPPORT.

None

If the software version of the


SingleRAN BTS is SRAN3.0 or later,
the parameter Is support SRAN
mode needs to be set to
SUPPORT(Support). If the software
version of the SingleRAN BTS is
earlier than SRAN3.0, the parameter
Is support SRAN mode needs to be
set to NOT_SUPPORT(Not Support).

NOT_SUPPORT

NOT_SUPPORT

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

HOALGORITHM1

HOALGORITHM1

None

None

None

None

None

None

None

None

None

None

None

None

None

LINE1_8K and LINE2_8K are most


commonly used.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

DES

None

100

100

100

100

GSM_PRIOR

GSM_PRIOR

None

None

63

63

75

75

85

85

80

80

85

80

None

None

None

None

None

None

63

63

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

YES

YES

YES

YES

None

None

None

None

None

None

-100

-100

None

None

YES

YES

YES

YES

None

None

240

240

None

None

None

None

None

None

None

None

ENABLED

ENABLED

DISABLED

DISABLED

None

None

None

None

None

None

None

None

NO

NO

None

None

NO

NO

OFF

OFF

120

120

OFF

OFF

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

352

352

352

352

None

None

None

None

NO

NO

NO

NO

None

None

None

None

YES

YES

NO

None

NO

None

NO

NO

NOTSUPPORT

NOTSUPPORT

UNSUPPORT

None

NOTSUPPORT

NOTSUPPORT

UNSUPPORT

None

NO

NO

NO

NO

NO

NO

T_20

T_20

None

None

None

None

CLOSE

None

None

None

ON

ON

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

CLOSE

YES

YES

10

10

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

None

None

ON

None

None

None

None

None

None

AISS

AISS

None

None

None

None

MBSC

None

10

10

None

None

YES

YES

BSC

None

None

None

3000

3000

60000

60000

1500

1500

1500

1500

3000

3000

1500

1500

1200

1200

3000

3000

12

When the transmission quality is


good, the recommended settings
are as follows: "Ring II Wait Time
Before Switch" = 0; "Ring II Try
Rotating Duration Time" = 60; "Ring
II Rotating Penalty Time" = 0;
"T200" = 12; "T203" = 1; and
"N200" = 3.
When the transmission quality is
bad, the recommended settings are
as follows: "Ring II Wait Time Before
Switch" = 30; "Ring II Try Rotating
Duration Time" = 60; "Ring II
Rotating Penalty Time" = 0; "T200"
= 24; "T203" = 3; and "N200" = 3.

50

50

50

50

200

200

60

60

150

150

60

60

60

60

When the transmission quality is


good, the recommended settings
are as follows: "Ring II Wait Time
Before Switch" = 0; "Ring II Try
Rotating Duration Time" = 60; "Ring
II Rotating Penalty Time" = 0;
"T200" = 12; "T203" = 1; and
"N200" = 3.
When the transmission quality is
bad, the recommended settings are
as follows: "Ring II Wait Time Before
Switch" = 30; "Ring II Try Rotating
Duration Time" = 60; "Ring II
Rotating Penalty Time" = 0; "T200"
= 24; "T203" = 3; and "N200" = 3.

360000

360000

360000

360000

2000

2000

10000

10000

10

10

500ms

500ms

500ms

500ms

20

20

10

10

1200

1200

5000

5000

1200

1200

1000

1000

1200

1200

3000

3000

3000

3000

1200

1200

NO

NO

YES

YES

255

255

None

None

63

63

10

10

10

10

None

None

None

None

90

90

90

90

170

170

4000

4000

80

80

ON

ON

NO

NO

60

60

40

40

55

55

40

40

55

55

YES

YES

60

60

OFF

OFF

60

60

70

70

10

10

None

None

None

DISABLE

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO

NO

NO

NO

10

10

None

None

None

None

NO

NO

None

None

20

20

15

15

None

None

None

None

63

63

OPEN

None

45

None

None

500

500

500

500

800

800

None

None

None

None

None

None

None

None

65

65

-100

For EPS4815 boards, the value of


this parameter is always "-1". For
other types of APMU boards, the
recommended value is "-100".

-100

-100

YES

YES

30

30

None

None

OFF

OFF

None

None

65535

65535

None

None

None

None

None

None

None

None

None

None

None

None

5000

5000

264

264

264

264

10

10

None

None

30

30

80

80

OFF

OFF

40

40

None

None

None

None

NOLIMIT

NOLIMIT

10

10

10

10

10

10

2000

2000

3000

3000

10

10

NO

NO

30

30

40

40

None

None

None

None

45

45

-19

If "Power System Type" is


"EPS4815", the recommended value
is "0". For other types of Power
System, the recommended value is
"-19".

-20

-20

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

12000

12000

60000

60000

None

None

None

None

TRRS

TRRS

None

None

None

None

None

None

None

None

None

None

None

None

60

60

60

67

50

50

50

62

ON

ON

M3UA_LOADSHARE_MOD

M3UA_LOADSHARE_MOD

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO

NO

NO

NO

NO

NO

NO

NO

None

None

10sec

10sec

90

90

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

AllowReCheckRes

AllowReCheckRes

None

None

255

255

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

YES

YES

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

NO

NO

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

20

If the board is configured with two to


four TRXs, the recommended value
of this parameter is 20.
If the board is configured with five
TRXs, the recommended value of
this parameter is 50.
If the board is configured with six
TRXs, the recommended value of
this parameter is 48.

5000

5000

Open

Open

None

None

None

None

None

None

None

None

None

None

None

None

NO

NO

None

None

64

64

64

64

None

None

None

DISABLE

80

80

50

50

68

68

10

10

10

10

TX_32

TX_32

None

None

None

None

T_20

T_20

500

500

None

None

None

None

None

None

INNER

None

None

ANY_ERR_RETURN

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

10

10

15

15

15

15

13

13

13

13

OFF

OFF

NO

NO

10

10

15

15

15

15

13

13

13

13

OFF

OFF

None

None

None

None

None

None

None

None

Guests

Guests

80

80

64

64

1000

1000

90

None

None

None

14

14

14

14

16

16

16

16

180

In Abis over TDM transmission, the


recommended value is 180; in Abis
over IP transmission, the
recommended value is 200.

15

15

10

10

20

20

32

32

16

16

16

16

18

18

18

18

15

15

90

90

100

100

55

55

60

60

55

55

18

18

18

18

75

75

30

30

18

18

15

15

19

19

28

28

23

23

31

31

63

63

21

21

25

25

YES

YES

32

32

NO

NO

10

10

GSM_PHASE_2

It is recommended that the value of


this parameter is the same as that
for "A Interface Tag".

None

None

40

40

40

40

40

40

60

60

60

60

60

60

None

None

None

None

None

None

None

None

None

None

None

None

None

None

CS1

CS1

MCS2

MCS2

20

20

MCS6

MCS6

UNFIXED

UNFIXED

2000

2000

UNFIXED

UNFIXED

UNFIXED

UNFIXED

40

40

30

30

30

30

None

None

YES

YES

None

None

None

None

NO

NO

120

120

10

10

PERMIT

PERMIT

None

None

NOTSUPPORT

NOTSUPPORT

None

None

None

None

None

None

None

None

50

50

10

10

35

35

NO

NO

None

None

None

None

255

255

No_Priority

No_Priority

95

95

NO

NO

LEVEL0

LEVEL0

90

90

DISABLE

DISABLE

None

None

DISABLE

DISABLE

DISABLE

DISABLE

None

None

None

None

None

None

None

None

None

None

None

None

NO

NO

FULL_RATE_VER11&FULL_RATE_VER21&FULL_RATE_VER30&HALF_RATE_VER11&HALF_RATE_VER20&HALF_RATE_VER30&FULL_RATE_VER5-0

FULL_RATE_VER11&FULL_RATE_VER21&FULL_RATE_VER30&HALF_RATE_VER11&HALF_RATE_VER20&HALF_RATE_VER30&FULL_RATE_VER5-0

OPEN

None

28

None

20

None

OPEN

None

57

None

42

None

YES

YES

20

20

30

30

None

None

27000

27000

34000

34000

26000

26000

280

280

15

15

300

300

INACTIVE

INACTIVE

OPEN

None

NOLIMIT

NOLIMIT

None

None

INACTIVE

INACTIVE

None

None

DENY

None

None

None

M3UA_ASP

M3UA_ASP

22

22

NO

NO

12

12

NO

NO

Active

Active

GSM

GSM

None

None

None

None

E1

E1

None

16

90

90

90

90

None

600

GMT+0800

None

Impact

Parameter Relationship

Access

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BSC

The value of this parameter should


be smaller than "AbisFCTimer2".

Read & Write

BSC

The value of this parameter should


be greater than "AbisFCTimer1".

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BSC

The value of this parameter is the


same as those of "Um Interface Tag" Read & Write
and "A Interface Tag".

BSC6900

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

PPP link

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BTS

The value of this parameter must be


smaller than "AC Voltage Upper
Read & Write
Threshold".

BTS

The value of this parameter must be


greater than "AC undervoltage
Read & Write
alarm threshold".

BTS

The value of this parameter must be


smaller than "AC overvoltage alarm Read & Write
threshold".

BTS

The value of this parameter must be


greater than "AC Voltage Lower
Read & Write
Threshold".

Cell

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

Current BFD session

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

This parameter can be configured


only when "BTS Software Version 1" Read & Write
is configured.

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

If the number of echo cancellations


performed by AEC exceeds "AEC
Detect Threshold" within the time
Read & Write
specified by "AEC Detect Time", the
TFO is closed forcibly.

Board

If the number of echo cancellations


performed by AEC exceeds "AEC
Detect Threshold" within the time
Read & Write
specified by "AEC Detect Time", the
TFO is closed forcibly.

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

Board

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Transmission resource group

When "BWMODE" in "ADD RSCGRP"


is set to HALF_DUPLEX, this
parameter is valid;if the "BWMODE"
in "ADD RSCGRP" of upper class and
lower class RSCGRP is set to
HALF_DUPLEX, the "AllBw" in "ADD
RSCGRP" of upper class RSCGRP can Read & Write
not less than the "AllBwE" in "ADD
RSCGRP" of lower class RSCGRP;The
"AllBw" in "ADD RSCGRP" of upper
class RSCGRP can not less than the
sum of "TxBw" and "RxBw" in "ADD
RSCGRP" of lower class RSCGRP.

BSC

None

Read & Write

Cell

None

Read & Write

Cell

The following condition must be


met:
"ALLOWAMRHALFRATEUSERPERC"
<= "ALLOWHALFRATEUSERPERC".

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

The following condition must be


met: "ALLOWHALFRATEUSERPERC"
>=
"ALLOWAMRHALFRATEUSERPERC".

Read & Write

E1/T1 link

None

Read & Write

PBE1T1

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

The recommended value of this


parameter is greater than twice
"Alarm Clear Accumulative Time
Threshold" and greater than twice
"Flash Alarm Occur Threshold".

Read & Write

BTS

None

Read & Write

BTS

The recommended value of this


parameter is greater than twice
"Alarm Clear Times Threshold".

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
GCELLPWRBASIC" command is set to
Read & Write
PWR2 and "DNPCEN" in the "SET
GCELLBASICPARA" command is set
to YES.

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "AMRDLQLTHRED" >=
"AMRDLQHTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "AMRDLQLTHRED" >=
"AMRDLQHTHRED".

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "AMRDLSSHTHRED" >=
"AMRDLSSLTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "AMRDLSSHTHRED" >=
"AMRDLSSLTHRED".

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"AMRFULLTOHALFHOALLOW" is set
to YES.

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
GCELLPWRBASIC" command is set to
Read & Write
PWR2 and "DNPCEN" in the "SET
GCELLBASICPARA" command is set
to YES.

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "AMRULQLOWTHRED" >=
"AMRULQHTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "AMRULQLOWTHRED" >=
"AMRULQHTHRED".

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "AMRULSSHTHRED" >=
"AMRULSSLTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "AMRULSSHTHRED" >=
"AMRULSSLTHRED".

Read & Write

BSC

None

Read & Write

MSC

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

None

None

Read & Write

None

None

Read & Write

IP path

None

Read & Write

BSC6900

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Board

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

TRX

None

Read & Write

TRX

None

Read & Write

BTS

The setting of this parameter


depends on "Board Type".

Read & Write

MTP3 link

None

Read & Write

SCTP link

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

None

None

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

MTP3 link

None

Read & Write

ATERCONSL

None

Read & Write

MTP3 link

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

In an enhanced concentric cell, if


"LOWRXLEVOLFORBIDSWITCH" is set
to ON, this parameter and
"OTOURECEIVETH" determine
whether the current uplink receive
level meets the condition for
assigning channels of the overlaid
subcell during the assignment of the
underlaid subcell channels and
overlaid subcell channels.
In a normal concentric cell, if
Read & Write
"LOWRXLEVOLFORBIDSWITCH" is set
to ON, this parameter, together with
"RECLEVTHRES" and "RECLEVHYST",
determines whether the current
uplink receive level meets the
condition for assigning channels of
the overlaid subcell during the
assignment of the underlaid subcell
channels and overlaid subcell
channels.

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

MSC

None

Read & Write

BSC

This parameter is used with "T18 -s"


in flow control over the A interface.
Read & Write
The value of this parameter should
be smaller than "T18 -s".

MSC

This parameter is used with "T17 -s"


in flow control over the A interface.
Read & Write
The value of this parameter should
be greater than "T17 -s".

BSC

None

Read & Write

BSC

None

Read & Write

MSC

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" is set to Concentric_cell.

Read & Write

Cell

This parameter is valid only when


"ATCBHoSwitch" is set to OPEN,
"IUOTP" is set to EDB_cell, or
"TIGHTBCCHSWITCH" is set to ON.

Read & Write

Cell

This parameter is valid only when


"ATCBHoSwitch" is set to OPEN,
"IUOTP" is set to EDB_cell, or
"TIGHTBCCHSWITCH" is set to ON.

Read & Write

BSC

None

Read & Write

BSC

If the resource usage on the Ater


interface exceeds the value of
"AterCongstRatio" and this
parameter is set to Open, the BSC
preferentially selects TCHF when
assigning traffic channels.

Read & Write

BSC

This parameter is valid only when


"AterCongHRFlag" is set to OPEN.

Read & Write

MTP3 link

None

Read & Write

BSC

None

Read & Write

E1/T1 link

None

Read & Write

BSC

None

Read & Write

E1/T1 link

None

Read & Write

E1/T1 link

None

Read & Write

ATERCONSL

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

MTP3 link

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

E1/T1 port

None

Read & Write

BTS

None

Read & Write

PPP link

None

Read & Write

MP group

None

Read & Write

BSC6900

None

Read & Write

BTS

This parameter is required only


when "Validate protocol type" is set
to "PAP_V" or "CHAP_V" with the
"ADD PPPLNK" command.

Read & Write

PPP link

None

Read & Write

MP group

None

Read & Write

BTS

This parameter is required only


when "Validate protocol type" is set
Read & Write
to "PAP_V" or "CHAP_V" in the "ADD
PPPLNK" command.

PPP link

None

Read & Write

MP group

None

Read & Write

BTS

None

Read & Write

PPP link

None

Read & Write

MP group

None

Read & Write

Ethernet port

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Channelized optical port

None

Read & Write

BSC

Generally, the value of this


parameter is equal to "Um Interface Read & Write
Tag" and "Um Interface Tag".

None

None

Read & Write

BTS

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

Ethernet port

None

Read & Write

BTS

This parameter can work with


"BTSPOWEROFFLOCKBCCH" in "SET
BTSLOCKBCCH" to determine
whether to shut down the TRX that
carries the main BCCH.

Read & Write

BTS

This parameter is valid only when


"BAKPWRSAVMETHOD" is set to
BYPWR.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

SCTP link

None

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BC

None

Read & Write

BTS

None

Read & Write

BTS

The value of this parameter must be


greater than "Float charging
Read & Write
voltage" and at least two volts lower
than "DC Voltage Upper Threshold".

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

SCCP

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


the ""INTERRATOUTBSCHOEN""
parameter regarding the "SET
GCELLHOBASIC" command is set to
YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"BETTERCELLHOEN" is set to YES
and "HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"BETTERCELLSTATTIME" >=
"BETTERCELLLASTTIME".

Read & Write

Cell

This parameter is valid only when


"BETTERCELLHOEN" is set to YES
and "HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"BETTERCELLSTATTIME" >=
"BETTERCELLLASTTIME".

Read & Write

Current BFD session

None

Read & Write

Current BFD session

None

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

If you set "Switch of stat blinking


alarm" to "ENABLE", you need to set
Read & Write
"Alarm switch of blinking filter" to
"ENABLE".

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

If you set "Switch of stat blinking


alarm" to "ENABLE", you need to set
Read & Write
"Alarm switch of blinking filter" to
"ENABLE".

BSC

None

Read & Write

BSC

None

Read & Write

Transport channel

None

Read & Write

Transport channel

None

Read & Write

Transport channel

None

Read & Write

BSC

This parameter is valid when


"BMTCFFLAG" in the "SET
Read & Write
BSCFCPARA" command is set to ON.

MP group

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

The value of this parameter must be


greater than or equal to "Position of Read & Write
Break Point 1".

Cell

None

Read & Write

Cell

This parameter is valid only when


"BQHOEN" is set to YES and
"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"BQSTATTIME" >= "BQLASTTIME".

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"BQHOEN" is set to YES and
"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"BQSTATTIME" >= "BQLASTTIME".

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

Board

None

Read & Write

None

None

Read & Write

Ethernet port

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

BTS

The setting of this parameter must


meet the following condition:
"FallBack Start Time" > "Ring II Wait Read & Write
Time Before Switch" + "Ring II Try
Rotating Duration Time".

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

E1/T1 link

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Adjacent node

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BTS

The IP address must have been


configured.

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

This parameter is valid only when


"BSCPMA" is set to YES.

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

When "BSCPMA" is set to YES and


"BSCQAD" is also set to Yes, highpriority calls try to preempt radio
resources of low-priority calls firstly
if radio resources are insufficient. If
no radio resources of low-priority
calls can be preempted, then the
Read & Write
high-priority calls are put into the
queue.
When "BSCPMA" is set to NO and
"BSCQAD" is set to Yes, high-priority
calls are directly put into the queue
if the radio resources are
insufficient.

BSC

This parameter is valid only when


"BSCQAD" is set to YES.

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

E1/T1 link

When configure TC data, for


example, select TC for "BM/TC config
Read & Write
Flag", or MTP2 for "Application
Type", the parameter should be set.

BSC

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

This parameter must be set when


"BTSMESRPTPREPROC" is set to
BTS_PreprocessingN.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

MSC

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

E1/T1 port

None

Read & Write

Cell

None

Read & Write

E1/T1 port

None

Read & Write

Board

None

Read & Write

Channelized optical port

None

Read & Write

IP logical port

None

Read & Write

E1/T1 port

None

Read & Write

BTS

None

Read & Write

BTS

The value range of this parameter


varies with BTS type. Different types
Read & Write
of BTSs support different type of
boards.

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

ATERCONSL

None

Read & Write

E1/T1 link

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Adjacent node

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BSC

The value of BtsLsStartMode should


be set when "BssLsGenMode" is set
Read & Write
to BTSPRIORITY, BSCPRIORITY, or
BTSONLY.

BTS

None

Cell

If the value of this parameter is


BSC_Preprocessing, the preprocessing is performed on the BSC.
In this case, the following
Read & Write
parameters are invalid:
"PRIMMESPPT", "BSMSPWRLEV", and
"MRPREPROCFREQ".

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

None

Read & Write

None

None

Read & Write

BTS

This parameter is used to caculate


BindWidth of BTSAbisHDLCPath:
1. When Transmission compression
ratio is within range of [1, 200],
BindWidth=16K*(amount of TRXs) +
64K*(amount of TRXs)*(Transmission
compression ratio)/100;
Read & Write
2. When Transmission compression
ratio is within range of [200, 250],
BindWidth=16K*(amount of TRXs) +
64K*(amount of TRXs)*(200 +
(Transmission compression ratio 200)*12)/100.

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

Current BFD session

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BTS

The setting of this parameter must


meet the following condition:
"FallBack Start Time" > "Ring II Wait Read & Write
Time Before Switch" + "Ring II Try
Rotating Duration Time".

SCTP link

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

IP logical port

The dynamic bandwidth switch is


turned only when the IPPM function
is activated through "ACT IPPM".

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

IP logical port

None

Read & Write

Transmission resource group

When "GRPT" in "ADD RSCGRP" is


set to IP, this parameter is valid.

Read & Write

IP logical port

None

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

This parameter has relations with


DCOMDCBM board

Read & Write

IP path

None

Read & Write

IP logical port

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

IP logical port

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"MEASURETYPE" in "SET
GCELLCCUTRANSYS" is set to
EnhMeasReport.

Read & Write

Cell

This parameter is valid only when


"MEASURETYPE" in "SET
GCELLCCUTRANSYS" is set to
EnhMeasReport.

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Ethernet port

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"EDGE" in "SET GCELLGPRS" is set
to YES.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

The value of this parameter must be


greater than "Float charging
voltage" and at least one volt lower Read & Write
than "DC overvoltage alarm
threshold".

BTS

The value of this parameter must be


greater than "Float charging
voltage" and at least three volts
Read & Write
lower than "DC overvoltage alarm
threshold".

BTS

The value of this parameter must be


smaller than "Even Charging
Read & Write
Voltage".

BTS

The value of this parameter must be


smaller than "Even Charging
Read & Write
Voltage".

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

MSC

None

Read & Write

Cell

This parameter is valid only when


"SDDYN" in "SET GCELLBASICPARA"
is set to YES.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

The parameter value corresponds to


the power of each passage on the
MRRU. If the cell is configured only
on one passage of the MRRU, then
Read & Write
the power assigned to another
passage of the operator must be set
to 0.

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

The value of this parameter must be


smaller than "DC undervoltage
Read & Write
alarm threshold".

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

The value of this parameter must be


smaller than "Low Temp Alarm
Read & Write
Assembled Bat2".

BTS

None

BTS

The value of this parameter must be


greater than "Lower Assembled Bat1 Read & Write
TEMP Measure".

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

BSC6900

None

Read & Write

IP path

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

ATERCONSL

None

Read & Write

ATERCONSL

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

ATERCONSL

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

MSC

None

Read & Write

Cell

None

Read & Write

IP path

When the value of "PATHCHK" in


"ADD IPPATH" is set to ENABLED,
this parameter is valid.

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

SCTP link

None

Read & Write

SCTP link

None

Read & Write

SCTP link

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

Board

None

Read & Write

Physical channel

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

Cell

This parameter is valid only when


"QTRUPWRSHARE" is not set to
NONE.

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Physical channel

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

E1/T1 link

When the value of "OPMODE" of


"BLK ACIC" is BYCICVALUE, the value Read & Write
of CIC needs to be set.

None

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

IP logical port

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu
and "SUPPORTDTM" is set to
SUPPORT.

Read & Write

BSC

None

Read & Write

Board

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

This parameter is valid only when


"AntiTheftAllow" is set to YES.

Read & Write

BSC6900

None

Read & Write

BTS

This parameter is valid only when


"AntiTheftAllow" is set to YES.

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BTS

The value range of this parameter


varies with BTS type. Different types
Read & Write
of BTSs support a different number
of cabinets.

BTS

The value range of this parameter


varies with BTS type. Different types
Read & Write
of BTSs support a different number
of cabinets.

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

MSC

None

Read & Write

NSE

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


"PWRBCDALLOWD" is set to YES.

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

This parameter, together with


"BANTIME", limits the handover
frequency in the cell.

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

None

None

Read & Write

TRX

This parameter is valid only when


"BSCDynSwitchTrxPAAllow" in "SET
BSCDSTPA" and "DYNOpenTrxPower" Read & Write
in "SET GCELLBASICPARA" are set to
YES.

BSC

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

SCTP link

None

Read & Write

BSC

This parameter is valid only when


"CHR Output Mode" is set to
"Common User Mode".

Read & Write

BSC

This parameter is valid only when


"CHR Output Mode" is set to
"Common User Mode".

Read & Write

BSC

This parameter is valid only when


"CHR Output Mode" is set to
"Specified User Mode".

Read & Write

BSC

This parameter is valid only when


"CHR Output Mode" is set to
"Common User Mode".

Read & Write

BSC6900

None

Read & Write

BSC6900

When the value of "ITFT" in "ADD


TRMMAP" is set to A or ABIS, this
parameter is valid.

Read & Write

BSC6900

When the value of "ITFT" in "ADD


TRMMAP" is set to ABIS, this
parameter is valid.

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC

This parameter is valid only when


"CHR Output Mode" is set to
"Common User Mode".

Read & Write

BSC

This parameter is valid only when


"CHR Output Mode" is set to
"Common User Mode".

Read & Write

BSC

This parameter is valid only when


"CHR Output Mode" is set to
"Common User Mode".

Read & Write

BSC

None

Read & Write

BSC

This parameter is valid only when


"CHR Output Mode" is set to
"Common User Mode".

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

TRX

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BSC

This parameter is valid only when


"CHR Output Mode" is set to
"Specified User Mode".

Read & Write

BSC6900

When the value of "ITFT" in "ADD


TRMMAP" is set to A or ABIS, this
parameter is valid.

Read & Write

BSC6900

When the value of "ITFT" in "ADD


TRMMAP" is set to ABIS, this
parameter is valid.

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC6900

none

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

BTS

The value range of this parameter


varies with BTS type. Different types
Read & Write
of BTSs support a different number
of cabinets.

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Transmission resource group

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

MSC

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

The value range of this parameter


varies with BTS type. Different types
Read & Write
of BTSs support a different number
of cabinets.

BTS

The value range of this parameter


varies with BTS type.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

The value of this parameter must be


greater than "Battery power-off
voltage", lower than "DC
Read & Write
overvoltage alarm threshold", and at
least two volts lower than "Float
charging voltage".

BTS

The value of this parameter must be


greater than "DC undervoltage
alarm threshold" and at least two
Read & Write
volts greater than "Even charging
voltage".

BTS

The value of this parameter must be


greater than "Battery power-off
voltage", lower than "DC
Read & Write
overvoltage alarm threshold", and at
least three volts lower than "Float
charging voltage".

BTS

The value of this parameter must be


greater than "DC Voltage Lower
Threshold" and at least one volt
Read & Write
greater than "Even charging
voltage".

Cell

None

Read & Write

Cell

None

Read & Write

SCCP

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

Ethernet port

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

Ethernet port

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

This parameter is required when the


Read & Write
Connection Type is Internal RNC.

BSC

This parameter is required when the


Read & Write
Connection Type is Internal RNC.

BSC

This parameter is required when the


Read & Write
Connection Type is Internal RNC.

Cell

None

Read & Write

Cell

None

Read & Write

Current BFD session

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

MSC

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

MSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "DLAFSREXQUALHIGHTHRED"
>= "DLAFSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "DLAFSREXQUALHIGHTHRED"
>= "DLAFSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "DLAHSREXQUALHIGHTHRED"
>= "DLAFSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "DLAHSREXQUALHIGHTHRED"
>= "DLAFSREXQUALLOWTHRED".

Read & Write

NSVC

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu.

Read & Write

Cell

This parameter is valid when


"FRINGEHOEN" is set to YES or
"LOADHOEN" is set to YES.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLOPTIMIZEDEN" is set to
YES.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "DLFSREXQUALHIGHTHRED"
>= "DLFSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "DLFSREXQUALHIGHTHRED"
>= "DLFSREXQUALLOWTHRED".

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "DLHSREXQUALHIGHTHRED"
>= "DLHSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "DLHSREXQUALHIGHTHRED"
>= "DLHSREXQUALLOWTHRED".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
Read & Write
"DLTHF1" + "DLHYSTF1" < "DLTHF2"
+ "DLHYSTF2".

Cell

The setting of this parameter must


meet the following condition:
Read & Write
"DLTHF2" + "DLHYSTF2" < "DLTHF3"
+ "DLHYSTF3".

Cell

The setting of this parameter must


meet the following condition:
Read & Write
"DLTHF2" + "DLHYSTF2" < "DLTHF3"
+ "DLHYSTF3".

Cell

The setting of this parameter must


meet the following condition:
"DLTHH1" + "DLHYSTH1" <
"DLTHH2" + "DLHYSTH2".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"DLTHH2" + "DLHYSTH2" <
"DLTHH3" + "DLHYSTH3".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"DLTHH2" + "DLHYSTH2" <
"DLTHH3" + "DLHYSTH3".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"DLTHWB1" + "DLHYSTWB1" <
"DLTHWB2" + "DLHYSTWB2".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"DLTHWB1" + "DLHYSTWB1" <
"DLTHWB2" + "DLHYSTWB2".

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
GCELLPWRBASIC" command is set to
Read & Write
PWR2 and "DNPCEN" in the "SET
GCELLBASICPARA" command is set
to YES.

Cell

The setting of this parameter must


meet the following conditions:
Read & Write
"DLLTFERLOWTH" < "DLLTFERTGT";
"DLLTFERLOWTH" < "DLLTFERUPTH".

Cell

The setting of this parameter must


meet the following condition:
"LTFERLOWTH" < "DLLTFERTGT" <
"LTFERUPTH".

Cell

The setting of this parameter must


meet the following conditions:
Read & Write
"DLLTFERUPTH" > "DLLTFERTGT";
"DLLTFERUPTH" > "DLLTFERLOWTH".

Cell

None

Read & Write

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
GCELLPWRBASIC" command is set to
Read & Write
PWR2 and "DNPCEN" in the "SET
GCELLBASICPARA" command is set
to YES.

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "DLQLOWTHRED" >=
"DLQHIGHTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "DLQLOWTHRED" >=
"DLQHIGHTHRED".

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
GCELLPWRBASIC" command is set to
Read & Write
PWR2 and "DNPCEN" in the "SET
GCELLBASICPARA" command is set
to YES.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid only when


"BQHOEN" in "SET GCELLHOBASIC"
is set to YES.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "DLREXLEVHIGHTHRED" >=
"DLREXLEVLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "DLREXLEVHIGHTHRED" >=
"DLREXLEVLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLOPTIMIZEDEN" is set to
YES.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLOPTIMIZEDEN" is set to
YES.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "DLSSHIGHTHRED" >=
"DLSSLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "DLSSHIGHTHRED" >=
"DLSSLOWTHRED".

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

The setting of this parameter must


meet the following conditions:
"DLTHF1" < "DLTHF2";
Read & Write
"DLTHF1" + "DLHYSTF1" < "DLTHF2"
+ "DLHYSTF2".

Cell

The setting of this parameter must


meet the following conditions:
"DLTHF2" < "DLTHF3";
Read & Write
"DLTHF2" + "DLHYSTF2" < "DLTHF3"
+ "DLHYSTF3".

Cell

The setting of this parameter must


meet the following conditions:
"DLTHF2" < "DLTHF3";

Read & Write

"DLTHF2" + "DLHYSTF2" < "DLTHF3"


+ "DLHYSTF3".

Cell

The setting of this parameter must


meet the following conditions:
"DLTHH1" < "DLTHH2";

Read & Write

"DLTHH1" + "DLHYSTH1" <


"DLTHH2" + "DLHYSTH2".

Cell

The setting of this parameter must


meet the following conditions:
"DLTHH2" < "DLTHH3";
"DLTHH2" + "DLHYSTH2" <
"DLTHH3" + "DLHYSTH3".

Read & Write

Cell

The setting of this parameter must


meet the following conditions:
"DLTHH2" < "DLTHH3";

Read & Write

"DLTHH2" + "DLHYSTH2" <


"DLTHH3" + "DLHYSTH3".

Cell

The setting of this parameter must


meet the following conditions:
"DLTHWB1" < "DLTHWB2";

Read & Write

["DLTHWB1" + "DLHYSTWB1" <


"DLTHWB2" + "DLHYSTWB2".

Cell

The setting of this parameter must


meet the following conditions:
"DLTHWB1" < "DLTHWB2";

Read & Write

["DLTHWB1" + "DLHYSTWB1" <


"DLTHWB2" + "DLHYSTWB2".

BTS

The setting of this parameter


depends on "Board Type".

Read & Write

BTS

The setting of this parameter


depends on "Board Type".

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"EGPRS2A" is set to YES.

Read & Write

Cell

This parameter is valid only when


"EGPRS2A" is set to YES.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

Cell

This parameter is valid only when


"PWRBCDALLOWD" is set to YES.

Read & Write

SCCP

When the value of "SPDF" in "ADD


N7DPC" is set to DNF, this
parameter is valid.

Read & Write

SCCP

None

Read & Write

E1/T1 link

None

Read & Write

E1/T1 link

None

Read & Write

BSC

None

Read & Write

SCCP

None

Read & Write

SCCP

None

Read & Write

BSC

DPX of Iur-g type

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

This parameter is valid only when


"BAKPWRSAVMETHOD" is set to
BYPWR.

Read & Write

BTS

This parameter is valid only when


"BAKPWRSAVMETHOD" is set to
BYPWR.

Read & Write

BTS

This parameter is valid only when


"BAKPWRSAVMETHOD" is set to
BYPWR.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

MP link

None

Read & Write

PPP link

None

Read & Write

SCTP link

None

Read & Write

Ethernet port

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Board

None

Read & Write

BSC6900

None

Read & Write

BSC

This parameter is valid only when


"IDXTYPE" is set to BYCELL.

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

IP route

None

Read & Write

Current BFD session

None

Read & Write

IP route

None

Read & Write

IP route

None

Read & Write

IP route

None

Read & Write

E1/T1 port

None

Read & Write

E1/T1 port

None

Read & Write

Cell

The value of DTLOADTHRED must be


set when "REASSEN" in the "SET
Read & Write
GCELLBASICPARA" command is set
to DIRECTRYEN.

Cell

None

Read & Write

BTS

The setting of this parameter


depends on "Board Type".

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

Channelized optical port

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

IP path

When the value of "PATHCHK" in


"ADD IPPATH" is set to ENABLED,
this parameter is valid.

Read & Write

Cell

A 3G neighboring cell can be added


into the candidate cell queue when
the following conditions are met:
"INTERRATOUTBSCHOEN" is set to
YES; "BET3GHOEN" is set to YES; the Read & Write
Ec/No of the 3G neighboring cell for
a period of time is greater than the
sun of "HOECNOTH3G" and
"ECNOOFF".

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell. The following condition
must be met: "EDBSTATTIME" >=
"EDBLASTTIME".

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell. The following condition
must be met: "EDBSTATTIME" >=
"EDBLASTTIME".

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu or Read & Write
SupportAsExtPcu.

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and "FRINGEHOEN"
Read & Write
is set to YES. The following condition
must be met: "EDGEADJSTATTIME"
>= "EDGEADJLASTTIME".

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and "FRINGEHOEN"
Read & Write
is set to YES. The following condition
must be met: "EDGEADJSTATTIME"
>= "EDGEADJLASTTIME".

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and "FRINGEHOEN"
Read & Write
is set to YES. The following condition
must be met: "EDGESTAT" >=
"EDGELAST".

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and "FRINGEHOEN"
Read & Write
is set to YES. The following condition
must be met: "EDGESTAT1" >=
"EDGELAST1".

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and "FRINGEHOEN"
Read & Write
is set to YES. The following condition
must be met: "EDGESTAT" >=
"EDGELAST".

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and "FRINGEHOEN"
Read & Write
is set to YES. The following condition
must be met: "EDGESTAT1" >=
"EDGELAST1".

None

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

MTP3 link

None

Read & Write

Board

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

E1/T1 link

When the value of "OPMODE" of


"BLK ACIC" is BYCICRANGE, the
value of ENDCIC needs to be set.

Read & Write

PBCIC

None

Read & Write

BSC

The setting of this parameter must


meet the following condition: When
"EndMonthDSTPA" and
"StartMonthDSTPA" are set to the
same value, "EndDayDSTPA" must
be later than "StartDayDSTPA".

Read & Write

BTS

The value of this parameter must be


greater than "Heater Startup
Read & Write
Temperature".

BSC

The setting of this parameter must


meet the following condition:
Read & Write
"EndMonthDSTPA" is the same as or
is later than "StartMonthDSTPA".

BTS

None

BSC

When "BSCDynSwitchTrxPAAllow" is
set to YES, the value of
Read & Write
"EndTimeTACloseTrxPA" must be set.

Read & Write

E1/T1 link

When the value of "OPMODE" of


"BLK AE1T1" is BYCICRANGE, the
value of ENDTS needs to be set.

E1/T1 link

When the value of "OPMODE" of


"BLK ATERE1T1" is BYCICRANGE, the Read & Write
value of ENDTS needs to be set.

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


"UTOOTRAFHOALLOW" is set to YES.
The following condition must be
Read & Write
met: "ENSOVERLDTHRSH" >
"ENGOVERLDTHRSH" >
"ENLOWLDTHRSH".

Cell

None

Read & Write

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


"UTOOTRAFHOALLOW" is set to YES.
The following condition must be
Read & Write
met: "ENSOVERLDTHRSH" >
"ENGOVERLDTHRSH" >
"ENLOWLDTHRSH".

BSC

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"UTOOTRAFHOALLOW" is set to YES.
The following condition must be
Read & Write
met: "ENSOVERLDTHRSH" >
"ENGOVERLDTHRSH" >
"ENLOWLDTHRSH".

Cell

None

Read & Write

SCCP

Negotiation with the peer network


element is required.

Read & Write

SCCP

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell and
"HOCTRLSWITCH" in "SET
GCELLHOBASIC" is set to
HOALGORITHM2.

Read & Write

Board

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

MSC

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

If "Sensor Type of External Analog 1"


is set to VOLTAGE, the unit of "Upper
Limit of Signal Output of External
Analog 1" is V; if "Sensor Type of
Read & Write
External Analog 1" is set to
CURRENT, the unit of "Upper Limit of
Signal Output of External Analog 1"
is A.

None

If "Sensor Type of External Analog 1"


is set to VOLTAGE, the unit of "Lower
Limit of Signal Output of External
Analog 1" is V; if "Sensor Type of
Read & Write
External Analog 1" is set to
CURRENT, the unit of "Lower Limit of
Signal Output of External Analog 1"
is A.

None

None

None

If "Sensor Type of External Analog 1"


is set to VOLTAGE, the unit of "Upper
Limit of Measurement Range of
External Analog 1" is V; if "Sensor
Read & Write
Type of External Analog 1" is set to
CURRENT, the unit of "Upper Limit of
Measurement Range of External
Analog 1" is A.

None

If "Sensor Type of External Analog 1"


is set to VOLTAGE, the unit of "Lower
Limit of Measurement Range of
External Analog 1" is V; if "Sensor
Read & Write
Type of External Analog 1" is set to
CURRENT, the unit of "Lower Limit of
Measurement Range of External
Analog 1" is A.

Read & Write

None

If "Sensor Type of External Analog 2"


is set to VOLTAGE, the unit of "Upper
Limit of Signal Output of External
Analog 2" is V; if "Sensor Type of
Read & Write
External Analog 2" is set to
CURRENT, the unit of "Upper Limit of
Signal Output of External Analog 2"
is A.

None

If "Sensor Type of External Analog 2"


is set to VOLTAGE, the unit of "Lower
Limit of Signal Output of External
Analog 2" is V; if "Sensor Type of
Read & Write
External Analog 2" is set to
CURRENT, the unit of "Lower Limit of
Signal Output of External Analog 2"
is A.

None

None

None

If "Sensor Type of External Analog 2"


is set to VOLTAGE, the unit of "Upper
Limit of Measurement Range of
External Analog 2" is V; if "Sensor
Read & Write
Type of External Analog 2" is set to
CURRENT, the unit of "Upper Limit of
Measurement Range of External
Analog 2" is A.

None

If "Sensor Type of External Analog 2"


is set to VOLTAGE, the unit of "Lower
Limit of Measurement Range of
External Analog 2" is V; if "Sensor
Read & Write
Type of External Analog 2" is set to
CURRENT, the unit of "Lower Limit of
Measurement Range of External
Analog 2" is A.

Read & Write

None

If "Sensor Type of External Analog 3"


is set to VOLTAGE, the unit of "Upper
Limit of Signal Output of External
Analog 3" is V; if "Sensor Type of
Read & Write
External Analog 3" is set to
CURRENT, the unit of "Upper Limit of
Signal Output of External Analog 3"
is A.

None

If "Sensor Type of External Analog 3"


is set to VOLTAGE, the unit of "Lower
Limit of Signal Output of External
Analog 3" is V; if "Sensor Type of
Read & Write
External Analog 3" is set to
CURRENT, the unit of "Lower Limit of
Signal Output of External Analog 3"
is A.

None

None

None

If "Sensor Type of External Analog 3"


is set to VOLTAGE, the unit of "Upper
Limit of Measurement Range of
External Analog 3" is V; if "Sensor
Read & Write
Type of External Analog 3" is set to
CURRENT, the unit of "Upper Limit of
Measurement Range of External
Analog 3" is A.

None

If "Sensor Type of External Analog 3"


is set to VOLTAGE, the unit of "Lower
Limit of Measurement Range of
External Analog 3" is V; if "Sensor
Read & Write
Type of External Analog 3" is set to
CURRENT, the unit of "Lower Limit of
Measurement Range of External
Analog 3" is A.

Read & Write

None

If "Sensor Type of External Analog 4"


is set to VOLTAGE, the unit of "Upper
Limit of Signal Output of External
Analog 4" is V; if "Sensor Type of
Read & Write
External Analog 4" is set to
CURRENT, the unit of "Upper Limit of
Signal Output of External Analog 4"
is A.

None

If "Sensor Type of External Analog 4"


is set to VOLTAGE, the unit of "Lower
Limit of Signal Output of External
Analog 4" is V; if "Sensor Type of
Read & Write
External Analog 4" is set to
CURRENT, the unit of "Lower Limit of
Signal Output of External Analog 4"
is A.

None

None

None

If "Sensor Type of External Analog 4"


is set to VOLTAGE, the unit of "Upper
Limit of Measurement Range of
External Analog 4" is V; if "Sensor
Read & Write
Type of External Analog 4" is set to
CURRENT, the unit of "Upper Limit of
Measurement Range of External
Analog 4" is A.

None

If "Sensor Type of External Analog 4"


is set to VOLTAGE, the unit of "Lower
Limit of Measurement Range of
External Analog 4" is V; if "Sensor
Read & Write
Type of External Analog 4" is set to
CURRENT, the unit of "Lower Limit of
Measurement Range of External
Analog 4" is A.

Cell

None

Read & Write

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"PWRBCDALLOWD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"PWRBCDALLOWD" is set to YES.

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

If "UPEXTTBFINACTDELAY" in the
"SET GCELLPRIVATEOPTPARA"
command is set to 0,
Read & Write
"EXTUTBFNODATA" must be 0. If
"UPEXTTBFINACTDELAY" is not set to
0, "EXTUTBFNODATA" can be 0 or 1.

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BTS

If this parameter is set to "YES", the


following condition must be met:
The setting of this parameter must
meet the following condition:
"FallBack Start Time" > "Ring II Wait
Time Before Switch" + "Ring II Try
Read & Write
Rotating Duration Time". If this
parameter is set to "NO", the
following condition must be met:
"FallBack Start Time" > "Ring I Wait
Time Before Switch" + "Ring I Try
Rotating Duration Time".

Board

None

Read & Write

BTS

None

Read & Write

Ethernet port

None

Read & Write

TRX

None

Read & Write

Ethernet port

None

Read & Write

MP group

None

Read & Write

Ethernet port

None

Read & Write

PPP link

None

Read & Write

IP logical port

This index can correspond with any


threshold (maximum value of 80) in
the six queues. The following
Read & Write
condition must be met: threshold x
64 x 1024 x logical port bandwidth
< 4294967295(0xFFFFFFFF).

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

TRX

None

Read & Write

PPP link

None

Read & Write

MP link

None

Read & Write

None

None

Read & Write

BTS

The value of this parameter must be


smaller than "Even charging
voltage" and at least two volts
Read & Write
higher than "DC undervoltage alarm
threshold".

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


the ""INTERRATCELLRESELEN""
parameter regarding the "SET
GCELLHOBASIC" command is set to
YES.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid when


"FHMODE" in the "SET GCELLHOPTP" Read & Write
command is not set to NO_FH.

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

IP logical port

None

Read & Write

BTS

None

Read & Write

Ethernet port

None

Read & Write

PPP link

None

Read & Write

MP group

None

Read & Write

Ethernet port

None

Read & Write

Cell

This parameter is valid only when


"RXQCKFALLHOEN" in "SET
GCELLHOBASIC" is set to YES. The
following condition must be met:
"FLTPARAA1" + "FLTPARAA2" +
"FLTPARAA3" + "FLTPARAA4" +
"FLTPARAA5" + "FLTPARAA6" +
"FLTPARAA7" + "FLTPARAA8" = 80.

Read & Write

Cell

This parameter is valid only when


"RXQCKFALLHOEN" in "SET
GCELLHOBASIC" is set to YES. The
following condition must be met:
"FLTPARAA1" + "FLTPARAA2" +
"FLTPARAA3" + "FLTPARAA4" +
"FLTPARAA5" + "FLTPARAA6" +
"FLTPARAA7" + "FLTPARAA8" = 80.

Read & Write

Cell

This parameter is valid only when


"RXQCKFALLHOEN" in "SET
GCELLHOBASIC" is set to YES. The
following condition must be met:
"FLTPARAA1" + "FLTPARAA2" +
"FLTPARAA3" + "FLTPARAA4" +
"FLTPARAA5" + "FLTPARAA6" +
"FLTPARAA7" + "FLTPARAA8" = 80.

Read & Write

Cell

This parameter is valid only when


"RXQCKFALLHOEN" in "SET
GCELLHOBASIC" is set to YES. The
following condition must be met:
"FLTPARAA1" + "FLTPARAA2" +
"FLTPARAA3" + "FLTPARAA4" +
"FLTPARAA5" + "FLTPARAA6" +
"FLTPARAA7" + "FLTPARAA8" = 80.

Read & Write

Cell

This parameter is valid only when


"RXQCKFALLHOEN" in "SET
GCELLHOBASIC" is set to YES. The
following condition must be met:
"FLTPARAA1" + "FLTPARAA2" +
"FLTPARAA3" + "FLTPARAA4" +
"FLTPARAA5" + "FLTPARAA6" +
"FLTPARAA7" + "FLTPARAA8" = 80.

Read & Write

Cell

This parameter is valid only when


"RXQCKFALLHOEN" in "SET
GCELLHOBASIC" is set to YES. The
following condition must be met:
"FLTPARAA1" + "FLTPARAA2" +
"FLTPARAA3" + "FLTPARAA4" +
"FLTPARAA5" + "FLTPARAA6" +
"FLTPARAA7" + "FLTPARAA8" = 80.

Read & Write

Cell

This parameter is valid only when


"RXQCKFALLHOEN" in "SET
GCELLHOBASIC" is set to YES. The
following condition must be met:
"FLTPARAA1" + "FLTPARAA2" +
"FLTPARAA3" + "FLTPARAA4" +
"FLTPARAA5" + "FLTPARAA6" +
"FLTPARAA7" + "FLTPARAA8" = 80.

Read & Write

Cell

This parameter is valid only when


"RXQCKFALLHOEN" in "SET
GCELLHOBASIC" is set to YES. The
following condition must be met:
"FLTPARAA1" + "FLTPARAA2" +
"FLTPARAA3" + "FLTPARAA4" +
"FLTPARAA5" + "FLTPARAA6" +
"FLTPARAA7" + "FLTPARAA8" = 80.

Read & Write

Cell

This parameter is valid only when


"RXQCKFALLHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

MSC

None

Read & Write

Board

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

MP group

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

None

The factor table index is configured


by setting the value of "FTI" in "ADD Read & Write
FACTORTABLE".

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"FULLTOHALFHODURATION" >=
"FULLTOHALFHOPERIOD".

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"FULLTOHALFHOSTATTIME" >=
"FULLTOHALFHOLASTTIME".

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Board

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Physical channel

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

Transmission resource group

None

Read & Write

Transmission resource group

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid when


"MEASURETYPE" is set to
EnhMeasReport.

Read & Write

Cell

None

Read & Write

Ethernet port

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"HALFTOFULLHOSTATTIME" >=
"HALFTOFULLHOLASTTIME".

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"HALFTOFULLHOSTATTIME" >=
"HALFTOFULLHOLASTTIME".

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

SCTP link

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
Read & Write
condition must be met:
"HCSSTATTIME" >= "HCSLASTTIME".

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
Read & Write
condition must be met:
"HCSSTATTIME" >= "HCSLASTTIME".

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"HIGHPRIUSERQUALFIRST" is set to
YES.

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu
and "SUPPORTDTM" is set to
SUPPORT.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

The value of this parameter must be


the same as that of
Read & Write
"HOCTRLSWITCH" in "SET
GCELLHOBASIC".

Cell

When parameter ""Quick handover


enable"" is configured to "YES",then
parameter ""Handover Direction
Forecast Enable"" can be configured
to "YES".Furthermore,before open
Read & Write
"Handover Direction Forecast
Enable", parameter ""Chain
Neighbour Cell Type"" of cell should
be configured correctly.

Cell

"Handover Direction Forecast


Statistic Times" >= "Handover
Direction Forecast Last Times"

Read & Write

Cell

"Handover Direction Forecast


Statistic Times" >= "Handover
Direction Forecast Last Times"

Read & Write

Cell

This parameter is valid only when


"QUICKHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

Cell

This parameter is valid only when


"BET3GHOEN" is set to YES. The
following condition must be met:
"HOSTAT3G" >= "HODURT3G".

Read & Write

Cell

This parameter is valid only when


"BET3GHOEN" is set to YES. The
following condition must be met:
"HOSTAT3GTDD" >=
"HODURT3GTDD".

Read & Write

This parameter is valid only when


the following conditions are met:

Cell

Cell

1. The
""INTERRATOUTBSCHOEN ""
regarding the "SET GCELLHOBASIC"
command is set to YES.
Read & Write
2. The
""BET3GHOEN"" parameter is set to
YES.
3. The ""FDDREP""
parameter regarding the "SET
GCELLCCUTRANSYS" command is
set to EcNo.

This parameter is valid only when


"QUICKHOEN" in "SET
GCELLHOBASIC" is set to YES. The
Read & Write
following condition must be met:
"HOSTATICTIME" >= "HOLASTTIME".

Cell

None

Read & Write

Cell

This parameter is valid only when


"QUICKHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

Cell

This parameter is valid only when


"LOWRXLEVOLFORBIDSWITCH" is set Read & Write
to ON.

Cell

This parameter is valid only when


the ""INTERRATOUTBSCHOEN""
parameter regarding the "SET
GCELLHOBASIC" command is set to
YES.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"HOOPTSEL" is set to
Pre_2G_CellThres.

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

TRX

This parameter depends on


"FHMODE" in "SET GCELLHOPTP".
This parameter can be set to
BaseBand_FH only when "FHMODE"
Read & Write
is set to BaseBand_FH or Hybrid_FH.
This parameter can be set to RF_FH
only when "FHMODE" is set to RF_FH
or Hybrid_FH.

Cell

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


the following conditions are met:
1. The ""INTERRATOUTBSCHOEN""
regarding the "SET GCELLHOBASIC"
command is set to YES.
2. The ""BET3GHOEN"" parameter is Read & Write
set to YES.
3. The ""FDDREP"" parameter
regarding the "SET
GCELLCCUTRANSYS" command is
set to RSCP.

MSC

None

Cell

This parameter is valid only when


"INTERRATOUTBSCHOEN" is set to
YES and "BET3GHOEN" is set to YES. Read & Write
The following condition must be
met: "HOSTAT3G" >= "HODURT3G".

Cell

This parameter is valid only when


"INTERRATOUTBSCHOEN" is set to
YES and "BET3GHOEN" is set to YES.
Read & Write
The following condition must be
met: "HOSTAT3GTDD" >=
"HODURT3GTDD".

Read & Write

Cell

This parameter is valid only when


"QUICKHOEN" in "SET
GCELLHOBASIC" is set to YES. The
Read & Write
following condition must be met:
"HOSTATICTIME" >= "HOLASTTIME".

SCCP

None

BTS

When the BTS or cell is


activated,the host type of OPC must
be single or primary if the host type
of BTS is single.
Read & Write
Otherwise, the host type of OPC
must be consistent with that of the
BTS.

Cell

None

Read & Write

Cell

This parameter is valid only when


"QUICKHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"GRADEACCALLOW" is set to YES.

Read & Write

BTS

None

Read & Write

BTS

The value of this parameter must be


smaller than "DC Undervoltage
Read & Write
Alarm Threshold".

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid when


"FHMODE" in the "SET GCELLHOPTP" Read & Write
command is not set to NO_FH.

BTS

None

Read & Write

Current BFD session

None

Read & Write

BTS

The value of this parameter must be


greater than "Low Temperature
Read & Write
Critical Point".

BTS

None

Read & Write

BTS

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

BTS

The value of this parameter must be


greater than "Lower Threshold of
Read & Write
Humidity Alarm".

BTS

The value of this parameter must be


greater than "Lower Threshold of
Read & Write
Humidity Alarm".

BTS

The value of this parameter must be


smaller than "Upper Threshold of
Read & Write
Humidity Alarm".

BTS

The value of this parameter must be


smaller than "Upper Threshold of
Read & Write
Humidity Alarm".

BTS

None

Read & Write

SCCP

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

SCCP

None

Read & Write

Cell

This parameter is valid only when


Read & Write
"IBCASOFTBLKSWITCH" is set to YES.

Cell

This parameter is valid only when


Read & Write
"IBCASOFTBLKSWITCH" is set to YES.

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

IP path

When the value of "PATHCHK" in


"ADD IPPATH" is set to ENABLED,
this parameter is valid.

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

Board

None

Read & Write

None

None

Read & Write

Cell

This parameter is one of the


conditions for the dynamic
conversion of the TCHF to the
SDCCH.
In addition to the condition that the
number of idle SDCCHs should be
smaller than or equal to
"IDLESDTHRES", the following three
conditions must be met to trigger
the conversion from the TCHF to the
Read & Write
SDCCH:
1. "SDDYN" in "SET
GCELLBASICPARA" is set to YES.
2. In the cell, the value of (number
of idle TCHFs + number of idle
TCHHs/2) is greater than four and is
greater than the number of TRXs.
Idle TCHFs exist in the cell.
3. Number of SDCCHs + 8 <
"CELLMAXSD".

Cell

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

Subsystem

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

IP route

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

Cell

This parameter is valid only when


"QUICKHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Cell

This parameter is valid only when


"IMMASSTAALLOW" is set to YES.

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Subsystem

This parameter is valid only when


"IDXTYPE" is set to BYIMSI.

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and
"INTRACELLFHHOEN" is set to YES.
The following condition must be
met: "INFHHOSTAT" >=
"INFHHOLAST".

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and
"INTRACELLFHHOEN" is set to YES.
The following condition must be
met: "INFHHOSTAT" >=
"INFHHOLAST".

Read & Write

BSC

Set when Allow Info Exchange at IurRead & Write


g is set to Yes

Board

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and
"INTRACELLFHHOEN" is set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and
"INTRACELLFHHOEN" is set to YES.

Read & Write

TRX

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


"INNLOADHOEN" is set to YES.

Read & Write

Cell

This parameter is valid only when


"INNLOADHOEN" is set to YES.

Read & Write

Cell

This parameter is valid only when


Read & Write
"OUTLOADHOENABLE" is set to YES.

BTS

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"SIGCHANHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

Inter-layer HO threshold of the


serving cell = "Inter-layer HO
threshold" - "Inter-layer HO
Hysteresis".
Inter-layer HO threshold of the
neighboring cell = "Inter-layer HO
threshold" + "Adjacent Cell Interlayer HO Hysteresis" - 64.
The value of "Inter-layer HO
threshold" can be set through "SET
GCELLHOBASIC".

Read & Write

Cell

None

Read & Write

Cell

When "Current HO Control


Algorithm" in "SET GCELLHOBASIC"
is set to HOALGORITHM1(Handover
algorithm I), "Inter-cell HO
Hysteresis" should be set within the
range of 64-127. When "Current HO
Read & Write
Control Algorithm" in "SET
GCELLHOBASIC" is set to
HOALGORITHM2(Handover
algorithm II), "Inter-cell HO
Hysteresis" should be set within the
range of 0-127.

Cell

This parameter is valid only when


"HOCTRLSWITCH" in "SET
GCELLHOBASIC" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"INTERFHOEN" is set to YES and
"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"INTERFERESTATTIME" >=
"INTERFERELASTTIME".

Read & Write

Cell

This parameter is valid only when


"INTERFHOEN" is set to YES and
"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"INTERFERESTATTIME" >=
"INTERFERELASTTIME".

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"INTERFTHRES0" >
"INTERFTHRES1".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"INTERFTHRES1" >
"INTERFTHRES2".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"INTERFTHRES2" >
"INTERFTHRES3".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"INTERFTHRES3" >
"INTERFTHRES4".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"INTERFTHRES4" >
"INTERFTHRES5".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"INTERFTHRES4" >
"INTERFTHRES5".

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

When "Inter-RAT In BSC Handover


Enable" is set to NO, this parameter Read & Write
must be set to NO.

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BSC

This parameter is valid only when


the ""INTERRATOUTBSCHOEN""
parameter regarding the "SET
GCELLHOBASIC" command is set to
YES.

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and
"INTRACELLHOEN" is set to YES.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

NSE

None

Read & Write

NSE

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

IP path

The "IPADDR" in "ADD IPPATH" can


not be at one network segment with
the peer IP address of SCTPLNK or
IPPATH whose local IP address is
device IP address of FG2/GOU in this
subrack;"IPADDR" and
Read & Write
"PEERIPADDR" in "ADD IPPATH" must
be at one network segment;
("IPADDR","PEERIPADDR","PEERMAS
K" in "ADD IPPATH") conflicts with
other IPPATH whose type is IUPS.

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

BSC6900

None

Read & Write

Ethernet port

None

Read & Write

BTS

The setting of this parameter cannot


be duplicate with "Slave Clock
Read & Write
Server IP Address".

BSC

None

BTS

The value of this parameter cannot


be the same as "Master Clock Server Read & Write
IP Address".

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

PPP link

None

Read & Write

Read & Write

MP group

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

None

None

Read & Write

BTS

This parameter is valid only when


"SERVICEMODE" in "MOD BTS" is set Read & Write
to IP.

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BTS

If the redundancy configuration


mode is not supported, only one
clock server can be configured.
Read & Write
Otherwise, two clock servers can be
configured.

BTS

If the redundancy configuration


mode is not supported, only one
clock server can be configured.
Read & Write
Otherwise, two clock servers can be
configured.

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Transmission resource group

None

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

NSE

None

Read & Write

IP Path

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BTS

This parameter can be set to YES


only when "BssLsGenMode" in "SET
BSSLS" is set to BTSPRIORITY,
BSCPRIORITY, or BTSONLY.

Read & Write

BSC

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

IP route

None

Read & Write

TRX

This parameter is valid only when


"IUOTP" in "MOD GCELL" is set to
Concentric_cell.

Read & Write

Cell

None

Read & Write

Cell

The following condition must be


met: "IUOHOSTATIME" >=
"IUOHODURATIME".

Read & Write

Cell

The following condition must be


met: "IUOHOSTATIME" >=
"IUOHODURATIME".

Read & Write

Cell

None

Read & Write

Board

None

Read & Write

None

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

None

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Channelized optical port

None

Read & Write

None

None

Read & Write

Channelized optical port

None

Read & Write

None

None

Read & Write

Channelized optical port

None

Read & Write

Board

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

MSP protect group

None

Read & Write

Cell

None

Read & Write

PPP link

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Ethernet port

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

None

None

Read & Write

IP logical port

None

Read & Write

IP logical port

None

Read & Write

IP logical port

None

Read & Write

IP logical port

None

Read & Write

IP logical port

None

Read & Write

Cell

None

Read & Write

Cell

There are four network layers, that


is, layer 1 to layer 4. A lower layer
No. indicates a higher priority. The
cell priority is determined by both
the network layer and the "PRIOR"
parameter.

Read & Write

Cell

The parameter is independent of


"Load Handover Support" and "
Enhanced Load HO Allowed".

Read & Write

BSC

Lb Congestion Protection Timer


Read & Write
1<Lb Congestion Protection Timer 2

BSC

Lb Congestion Protection Timer


Read & Write
1<Lb Congestion Protection Timer 2

BSC

If this parameter is not set to CLOSE,


it value must not be the same as
Read & Write
"LDRSND", "LDRTRD", or "LDRFST".

BSC

If this parameter is not set to CLOSE,


it value must not be the same as
Read & Write
"LDRSND", "LDRTRD", or
"LDRFOUH".

BSC

If this parameter is not set to CLOSE,


it value must not be the same as
Read & Write
"LDRFST", "LDRTRD", or "LDRFOUH".

SCCP

None

Read & Write

Ethernet port

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1.

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and "LEVHOEN" is
set to YES. The following condition
must be met: "LEVSTAT" >=
"LEVLAST".

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and "LEVHOEN" is
set to YES. The following condition
must be met: "LEVSTAT" >=
"LEVLAST".

Read & Write

Board

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

LAPDLNK

None

Read & Write

None

None

Read & Write

MTP3 link

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Board

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

SCCP

None

Read & Write

SCCP

None

Read & Write

When the cell is a 2G external cell,


this parameter is valid only when
the "" OutBscLoadHoEn"" parameter
regarding the "SET GCELLHOAD"
command is set to YES.
When the cell is a 3G external
cell, this parameter is valid only
when either of the following
conditions is met:

Cell

1. The
""INTERRATOUTBSCHOEN""
parameter regarding the "SET
GCELLHOBASIC" is set to YES and
Read & Write
the ""OutSysLoadHoEn "" parameter
regarding the "SET
GCELLHOINTERRATLDB" command is
set to YES.
2. The
""InterRatServiceLoadHoSwitch""
parameter is not set to OFF.
When the cell is under the
BSC, this parameter is valid only
when the ""LoadHoEn"" parameter
regarding the "SET GCELLHOBASIC"
command is set to YES.

MSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

Cell

This parameter can be set only


when "Load Handover Support" is
set to Yes.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

The parameter value cannot be


larger than the value of "PBGT HO
Threshold". The parameter takes
effect only when "Enhanced Load
HO Allowed" is enabled.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" in "SET
GCELLHOBASIC" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" in "SET
GCELLHOBASIC" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"LOADHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

Cell

This parameter is valid only when


"LOADHOEN" in "SET
GCELLHOBASIC" is set to YES. The
value of this parameter must be
smaller than "LOADOFFSET".

Read & Write

Cell

The parameter takes effect only


when the enhanced load handover
algorithm is enabled.

Read & Write

Cell

This parameter is valid only when


"LOADHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

The parameter is independent of


"Load Handover Support" and
"Enhanced Load HO Allowed".

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BTS

The IP address must be in the same


network segment as "Peer IP
Read & Write
address".

BTS

The IP address must be in the same


network segment as "Peer IP
Read & Write
address".

BSC6900

None

Read & Write

MP group

None

Read & Write

NSE

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

SCTP link

None

Read & Write

SCTP link

None

Read & Write

BSC6900

None

Read & Write

SCTP link

When the value of "MODE" in "ADD


SCTPLNK" is set to Client, this
parameter can be modified.

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

SCTP link

This parameter determines whether


"LOGPORTSN" and "LOGPORTNO" in Read & Write
"ADD SCTPLNK" are valid.

SCTP link

When the value of "LOGPORTFLAG"


in "ADD SCTPLNK" is set to ON, this
parameter is valid.

Read & Write

SCTP link

When the value of "LOGPORTFLAG"


in "ADD SCTPLNK" is set to ON, this
parameter is valid.

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BC

None

Read & Write

E1/T1 port

None

Read & Write

LAPDLNK

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

E1/T1 port

None

Read & Write

Loopback optical port

None

Read & Write

BSC

None

Read & Write

IP logical port

None

Read & Write

Cell

This parameter is valid when


"FLEXABISMODE" in the "MOD BTS"
command is set to YES.

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

IP path

When the value of "CARRYFLAG" in


"ADD IPPATH" is set to IP LGCPORT,
this parameter is valid.

Read & Write

IP logical port

None

Read & Write

IP logical port

None

Read & Write

IP path

When the value of "CARRYFLAG" in


"ADD IPPATH" is set to IP LGCPORT,
this parameter is valid.

Read & Write

ATM logical port

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

The value of this parameter must be


smaller than "DC Undervoltage
Read & Write
Alarm Threshold".

BSC

If this parameter is not set to CLOSE,


it value must not be the same as
Read & Write
"LDRSND", "LDRFST", or
"LDRFOUH".

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

The value of this parameter must be


smaller than "High Temperature
Read & Write
Critical Point".

BTS

None

Read & Write

Cell

The setting of this parameter must


meet the following conditions:
"LTFERLOWTH" < "LTFERTGT";
"LTFERLOWTH" < "LTFERUPTH".

Read & Write

Cell

The setting of this parameter must


meet the following conditions:
"LTFERLOWTH" < "LTFERTGT";
"LTFERTGT" < "LTFERUPTH".

Read & Write

Cell

The setting of this parameter must


meet the following conditions:
"LTFERUPTH" > "LTFERTGT";
"LTFERUPTH" > "LTFERLOWTH".

Read & Write

Cell

None

Read & Write

Board

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

SCTP link

None

Read & Write

None

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

Cell

None

Read & Write

Board

None

Read & Write

Cell

This parameter is valid when "


MAINBCCHPWRDTEN " in the " SET
GCELLOTHEXT " command is set to
YES.

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid when "


MAINBCCHPWRDTEN " in the " SET
GCELLOTHEXT " command is set to
YES.

Read & Write

Cell

This parameter is valid when "


MAINBCCHPWRDTEN " in the " SET
GCELLOTHEXT " command is set to
YES.

Read & Write

Cell

This parameter is valid when "


MAINBCCHPWRDTEN " in the " SET
GCELLOTHEXT " command is set to
YES.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IBCAALLOWED" in "SET
GCELLCHMGAD" is set to YES.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

MP group

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

PPP link

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

SCTP link

None

Read & Write

IP logical port

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

This parameter is valid only when


"BAKPWRSAVMETHOD" is set to
BYPWR.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

MP group

None

Read & Write

PPP link

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

SCTP link

None

Read & Write

BSC

This parameter is valid only when


"TYPE" in "SET BSCPCUTYPE" is set
to OUTER.

Read & Write

TRX

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

PPP link

None

Read & Write

MP group

None

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

TRX

None

Read & Write

None

None

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"MEASURETYPE" in "SET
GCELLCCUTRANSYS" is set to
EnhMeasReport.

Read & Write

Cell

This parameter is valid only when


"MEASURETYPE" in "SET
GCELLCCUTRANSYS" is set to
EnhMeasReport.

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

This parameter is required when


"MLPPP type" is set to "MCPPP" with Read & Write
the "ADD BTSMPGRP".

MP group

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

"BTSTYPE" identifies the value range


of this parameter. The number of
cabinets supported by the BTS
Read & Write
depends on the type of the BTS. For
details, see the parameter
description of the command.

Cell

None

Read & Write

BTS

None

Read & Write

Board

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

Cell

None

Read & Write

BSC

Set when Allow Common


Measurement at Iur-g is set to Yes

Read & Write

Cell

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

BTS

None

Read & Write

MP group

None

Read & Write

Cell

None

Read & Write

IP logical port

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is based on


"HOCDCMINDWPWR" and
"HOCDCMINUPPWR". Different offset
can be set for different neighboring
cells. The following condition must
be met for a neighboring cell to be
added into the candidate cell queue: Read & Write
Neighboring cell uplink level >=
("HOCDCMINUPPWR" +
"MINOFFSET"); Neighboring cell
downlink level >=
("HOCDCMINDWPWR" +
"MINOFFSET").

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1.

Read & Write

Cell

This parameter is valid only when


"SDDYN" in "SET GCELLBASICPARA"
is set to YES.

Cell

A 3G cell can be added into the


candidate cell queue when the
following conditions are met:
"INTERRATOUTBSCHOEN" is set to
Read & Write
YES; "BET3GHOEN" is set to YES; the
RSCP of the 3G cell for a period of
time is greater than the sum of
"HORSCPTH3G" and "RSCPOFF".

Ethernet port

None

Read & Write

Current BFD session

None

Read & Write

Ethernet port

None

Read & Write

Current BFD session

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

SCTP link

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

MSP protect group

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"QUICKHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

BTS

None

Read & Write

MP group

None

Read & Write

None

None

Read & Write

BTS

This parameter can be set to


MODE5_1 or MODE6_1 only when
"FLEXABISMODE" is set to
FLEX_ABIS.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

MP group

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter must be set when


"BTSMESRPTPREPROC" is set to
BTS_PreprocessingN.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

MSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

MSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"QUICKHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

Cell

None

Read & Write

MSP protect group

None

Read & Write

Cell

None

Read & Write

Cell

The value of this parameter must be


smaller than or equal to "PDCH
Read & Write
Downlink Multiplex Threshold".

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

E1/T1 port

None

Read & Write

MTP3 link

None

Read & Write

None

None

Read & Write

SCTP link

None

Read & Write

BTS

None

Read & Write

Ethernet port

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid when


Read & Write
"TCMUTEDETECTFLAG" is set to YES.

Cell

This parameter is valid when


Read & Write
"TCMUTEDETECTFLAG" is set to YES.

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

MP group

None

Read & Write

MP group

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

Cell

N200ESTAB must be set when


"N200PARASWITCH" is set to YES.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BC

None

Read & Write

BC

None

Read & Write

BC

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu or Read & Write
SupportAsExtPcu.

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu or Read & Write
SupportAsExtPcu.

BSC

None

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu or Read & Write
SupportAsExtPcu.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"QUICKHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

Cell

None

Read & Write

BSC

The following condition must be


met: "NcellInterFLevelThres1" >
"NcellInterFLevelThres0".

Read & Write

BSC

The following condition must be


met: "NcellInterFLevelThres2" >
"NcellInterFLevelThres1" >
"NcellInterFLevelThres0".

Read & Write

BSC

The following condition must be


met: "NcellInterFLevelThres3" >
"NcellInterFLevelThres2" >
"NcellInterFLevelThres1".

Read & Write

BSC

The following condition must be


met: "NcellInterFLevelThres4" >
"NcellInterFLevelThres3" >
"NcellInterFLevelThres2".

Read & Write

BSC

The following condition must be


met: "NcellInterFLevelThres5" >
"NcellInterFLevelThres4" >
"NcellInterFLevelThres3".

Read & Write

BSC

The following condition must be


met: "NcellInterFLevelThres6" >
"NcellInterFLevelThres5" >
"NcellInterFLevelThres4".

Read & Write

BSC

The following condition must be


met: "NcellInterFLevelThres7" >
"NcellInterFLevelThres6" >
"NcellInterFLevelThres5".

Read & Write

BSC

The following condition must be


met: "NcellInterFLevelThres7" >
"NcellInterFLevelThres6".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"NCHSTARTBLOCK"" <=
"NCHOCBLOCKNUM".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"NCHSTARTBLOCK"" <=
"NCHOCBLOCKNUM".

Read & Write

Cell

None

Read & Write

SCCP

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

IP route

None

Read & Write

None

None

Read & Write

SCCP

This parameter depends on network


Read & Write
planning.

None

None

Read & Write

Cell

None

Read & Write

BTS

The value range of this parameter


varies with BTS type. Different types
Read & Write
of BTSs support a different number
of cabinets.

BTS

The value range of this parameter


varies with BTS type.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and
"NOAMRFULLTOHALFHOALLOW" is
set to YES.

Read & Write

Adjacent node

None

Read & Write

Cell

This parameter is valid only when


"NODLMRHOEN" in "SET
GCELLHOEMG" is set to YES.

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"NODLMRHOEN" in "SET
GCELLHOEMG" is set to YES.

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BTS

The value of this parameter must be


8C smaller than "Derating TEMP
Read & Write
Threshold".

BSC

None

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

BTS

This parameter is valid only when


"ENABLE" is set to YES.

Read & Write

None

None

Read & Write

Cell

This parameter is valid only when


"MEASURETYPE" in "SET
GCELLCCUTRANSYS" is set to
EnhMeasReport.

Read & Write

Cell

This parameter is valid only when


"MEASURETYPE" in "SET
GCELLCCUTRANSYS" is set to
EnhMeasReport.

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

NSE

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" in "SET
GCELLHOBASIC" is set to
HOALGORITHM2.

Read & Write

Cell

None

Read & Write

NSVC

None

Read & Write

NSVC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Ethernet port

None

Read & Write

PPP link

None

Read & Write

MP group

None

Read & Write

IP logical port

None

Read & Write

Ethernet port

None

Read & Write

Port queue

None

Read & Write

Port queue

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

Transport channel

None

Read & Write

Transport channel

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

E1/T1 link

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

E1/T1 link

None

Read & Write

E1/T1 link

None

Read & Write

E1/T1 link

None

Read & Write

None

None

Read & Write

PBCIC

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell and "OPTILAYER" is
set to SysOpt.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell and "OPTILAYER" is
set to SysOpt.

Read & Write

TRX

This parameter is valid only when


"TRXPRIALLOW" is set to YES.

Read & Write

Board

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"LOADHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell. The following condition
must be met:
"OUTSERIOVERLDTHRED" >
"OUTGENOVERLDTHRED" >
"OUTLOWLOADTHRED".

Read & Write

TRX

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


Read & Write
"OUTLOADHOENABLE" is set to YES.

Cell

This parameter is valid only when


Read & Write
"OUTLOADHOENABLE" is set to YES.

Cell

This parameter is valid only when


"OUTLOADHOENABLE" is set to YES
and "IUOTP" in "ADD GCELL" is set
to EDB_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell. The following condition
must be met:
"OUTGENOVERLDTHRED" >
"OUTLOWLOADTHRED".

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell. The following condition
must be met:
"OUTSERIOVERLDTHRED" >
"OUTGENOVERLDTHRED" >
"OUTLOWLOADTHRED".

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BSC

This parameter is valid only when


"OUTSYSSERVICEHOEN" is set to
YES.

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BTS

The value of this parameter must be


8C greater than "Normal Work TEMP Read & Write
Threshold".

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid when


"ALLOWG2FLOWCTRALGL" in the
Read & Write
"SET BSCFCPARA" command is set to
YES.

Cell

None

Cell

This parameter is valid when


"ALLOWG2FLOWCTRALGL" in the
Read & Write
"SET BSCFCPARA" command is set to
YES.

Cell

None

Read & Write

Cell

None

Read & Write

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

TRX

This parameter is valid only when


"BSCDynSwitchTrxPAAllow" in "SET
BSCDSTPA","DYNOpenTrxPower" in
"SET GCELLBASICPARA" and "CPS"
are set to YES.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

IP path

None

Read & Write

IP path

None

Read & Write

IP path

None

Read & Write

Cell

This parameter is valid only when


"PWRBCDALLOWD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2.

Read & Write

IP path

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and "PBGTHOEN" is
Read & Write
set to YES. The following condition
must be met: "PBGTSTAT" >=
"PBGTLAST".

Cell

None

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1 and "PBGTHOEN" is
Read & Write
set to YES. The following condition
must be met: "PBGTSTAT" >=
"PBGTLAST".

BSC

This parameter is valid only when


"TYPE" in "SET BSCPCUTYPE" is set
to OUTER.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

None

Read & Write

PBCIC

None

Read & Write

Read & Write

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsExtPcu.

Read & Write

PBE1T1

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

SCCP

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

The peer IP address and the local IP


address specified by "Local IP
address" must be on the same
network segment.

Read & Write

BTS

The peer IP address and the local IP


address specified by "Local IP
address" must be on the same
network segment.

Read & Write

BSC6900

None

Read & Write

MP group

None

Read & Write

None

None

Read & Write

SCTP link

None

Read & Write

SCTP link

None

Read & Write

IP path

"IPADDR" and "PEERIPADDR" in


"ADD IPPATH" must be at one
network segment;
Read & Write
("IPADDR","PEERIPADDR","PEERMAS
K" in "ADD IPPATH") conflicts with
other IPPATH whose type is IUPS.

IP path

("IPADDR","PEERIPADDR","PEERMAS
K" in "ADD IPPATH") conflicts with
Read & Write
other IPPATH whose type is IUPS.

SCTP link

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

IP path

When the value of "PATHCHK" in


"ADD IPPATH" is set to ENABLED,
this parameter is valid.

Read & Write

BTS

None

Read & Write

PPP link

None

Read & Write

MP link

None

Read & Write

NSE

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

IP Path

None

Read & Write

Board

The phb of the traffic's transmission


path is determined like this: if the
phb of this transmission path is
QOS, use the traffic's phb from
TRMMAP; if the phb of this
Read & Write
transmission path is
BE,AF11,AF12,AF13,AF21,AF22,AF23
,AF31,AF32,AF33,AF41,AF42,AF43,E
F, use the phb of transmission path.

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BC

None

Read & Write

BTS

This parameter must meet the


following requirements: The sum of
the value of "Max subframe length"
and 8 must be smaller than the
value of this parameter.

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu or Read & Write
SupportAsExtPcu.

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

IP logical port

None

Read & Write

IP logical port

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

E1/T1 link

None

Read & Write

E1/T1 link

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

E1/T1 port

None

Read & Write

None

None

Read & Write

E1/T1 link

None

Read & Write

Board

None

Read & Write

E1/T1 port

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Loopback optical port

None

Read & Write

Board

None

Read & Write

Channelized optical port

None

Read & Write

Ethernet port

If port 0 or port 4 of the FG2a board


is set to the GE port, the port
number can only be 0 or 4.
Otherwise, the port number ranges
Read & Write
from 0 to 7. If only port 0 is set to
the GE port, ports 1-3 are
unavailable. If port 4 is set to the GE
port, ports 5-7 are unavailable.

IP logical port

None

Read & Write

E1/T1 port

None

Read & Write

E1/T1 port

None

Read & Write

PBE1T1

None

Read & Write

PBSL

None

Read & Write

BTS

None

Read & Write

PPP link

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

Ethernet port

None

Read & Write

BTS

None

Read & Write

Cell

If this parameter is BCCHExt,"CCCH


Blocks Reserved for AGCH" must be Read & Write
more than 0.

None

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

TRX

None

Read & Write

TRX

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

PPP link

None

Read & Write

PPP link

None

Read & Write

MP link

None

Read & Write

IP logical port

None

Read & Write

MP group

None

Read & Write

BSC6900

When the value of "PORTPROTYPE"


in "ADD PORTFLOWCTRLPARA" is set Read & Write
to IP, this parameter should be set.

BSC

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

This parameter must be set when


"BTSMESRPTPREPROC" is set to
BTS_Preprocessing. This parameter
must be set to NO when "MPMODE" Read & Write
of the BTS that serving this cell is
set to MODE4_1 and there are more
than two SDCCHs.

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Cell

None

Read & Write

Cell

This parameter, together with


"LAYER", determines the priority of
the cell.

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

SCCP

None

Read & Write

None

None

Read & Write

IP route

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

SCCP

None

Read & Write

BC

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"TURNOFFENABLE" is set to YES.

Read & Write

BSC

None

Read & Write

E1/T1 port

None

Read & Write

Board

None

Read & Write

Channelized optical port

None

Read & Write

BSC

This parameter is valid only when


Read & Write
"PS CHR Record Switch" is set to on.

BSC

This parameter is valid only when


Read & Write
"PS CHR Record Switch" is set to on.

BSC

This parameter is valid only when


Read & Write
"PS CHR Record Switch" is set to on.

BSC

This parameter is valid only when


Read & Write
"PS CHR Record Switch" is set to on.

BSC

This parameter is valid only when


Read & Write
"PS CHR Record Switch" is set to on.

BSC6900

None

Read & Write

BSC6900

None

Read & Write

NSE

None

Read & Write

BSC6900

When the value of "ITFT" in "ADD


TRMMAP" is set to ABIS, this
parameter is valid.

Read & Write

BSC6900

When the value of "ITFT" in "ADD


TRMMAP" is set to ABIS, this
parameter is valid.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

When the value of "ITFT" in "ADD


TRMMAP" is set to ABIS, this
parameter is valid.

Read & Write

BSC6900

When the value of "ITFT" in "ADD


TRMMAP" is set to ABIS, this
parameter is valid.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

This parameter is valid only when


"PSRCDSW" is set to on.

Read & Write

Cell

The value of this parameter must be


smaller than "RACH Busy Threshold"
Read & Write
in the "SET GCELLCCBASIC"
command.

BTS

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

NSE

None

Read & Write

BSC6900

None

Read & Write

E1/T1 port

None

Read & Write

E1/T1 port

None

Read & Write

E1/T1 port

None

Read & Write

E1/T1 port

None

Read & Write

BTS

None

Read & Write

Ethernet port

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

This parameter is valid only when


"BAKPWRSAVMETHOD" is set to
BYPWR.

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Port queue

None

Read & Write

Port queue

None

Read & Write

Port queue

None

Read & Write

Port queue

None

Read & Write

Port queue

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"QCKMVHOEN" in "SET
GCELLHOBASIC" is set to YES. The
following condition must be met:
"QCKSTATCNT" >= "QCKTRUECNT".

Read & Write

Cell

This parameter is valid only when


"QCKMVHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

Cell

This parameter is valid only when


"QCKMVHOEN" in "SET
GCELLHOBASIC" is set to YES. The
following condition must be met:
"QCKSTATCNT" >= "QCKTRUECNT".

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"QTRUPWRSHARE" is not set to
NONE. The following condition must Read & Write
be met: "QTRUDNPWRSTATTIME" >=
"QTRUDNPWRLASTTIME".

Cell

This parameter is valid only when


"QTRUPWRSHARE" is not set to
NONE. The following condition must Read & Write
be met: "QTRUDNPWRSTATTIME" >=
"QTRUDNPWRLASTTIME".

Cell

None

Read & Write

BTS

This parameter must be equal to or


greater than 0.6x"CHKOFFTIMES"
and equal to or less than
"CHKOFFTIMES".

BTS

This parameter must be equal to or


greater than 0.6x"CHKONTIMES" and Read & Write
equal to or less than "CHKONTIMES".

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

This parameter is valid only when


"R0BatAllow" is set to YES.

Read & Write

Read & Write

BTS

This parameter is valid only when


"R0BatAllow" is set to YES.

Read & Write

BTS

This parameter is valid only when


"R0BatAllow" is set to YES.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

This parameter is valid only when


"R1BatAllow" is set to YES.

Read & Write

BTS

This parameter is valid only when


"R1BatAllow" is set to YES.

Read & Write

BTS

This parameter is valid only when


"R1BatAllow" is set to YES.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

This parameter is valid only when


"R2BatAllow" is set to YES.

Read & Write

BTS

This parameter is valid only when


"R2BatAllow" is set to YES.

Read & Write

BTS

This parameter is valid only when


"R2BatAllow" is set to YES.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu.

Read & Write

Cell

None

Read & Write

Cell

The value of this parameter must be


smaller than "RACH Busy Threshold"
Read & Write
in the "SET GCELLCCBASIC"
command.

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

TRX

None

Read & Write

IP logical port

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid when


"REASSEN" in the "SET
GCELLCCBASIC" command is set to
YES.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Read & Write
Concentric_cell and "ENIUO" is set to
OFF.

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Read & Write
Concentric_cell and "ENIUO" is set to
OFF.

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

BSC

None

Read & Write

IP logical port

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Board

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

IP route

None

Read & Write

NSE

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid when


"REPEATDLFASET" is set to YES.

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid when


"DYNOpenTrxPower" in the "SET
GCELLBASICPARA" command is set
to YES.

Read & Write

BSC

None

Read & Write

BSC

This parameter is valid only when


"ResetAlmDelaySwitch" is set to
YES.

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

PPP link

None

Read & Write

MP link

None

Read & Write

BSC6900

None

Read & Write

BSC

Set when Allow Common


Measurement at Iur-g is set to Yes or
Read & Write
Allow Info Exchange at Iur-g is set to
Yes

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

NSE

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BSC

RMTTCATERTRANSMODE must be set


when "ISTCCENTRAL" in the "ADD
Read & Write
SUBRACK" command is set to YES.

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

IP logical port

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"MEASURETYPE" in "SET
GCELLCCUTRANSYS" is set to
EnhMeasReport.

Read & Write

Cell

This parameter is valid only when


"MEASURETYPE" in "SET
GCELLCCUTRANSYS" is set to
EnhMeasReport.

Read & Write

AAL2 path

When the value of "ADDTORSCGRP"


in "ADD AAL2PATH" is set to YES,
Read & Write
this parameter is valid.

IP logical port

None

Read & Write

Transmission resource group

None

Read & Write

Cell

None

Read & Write

Cell

A 3G cell can be added into the


candidate cell queue when the
following conditions are met:
"INTERRATOUTBSCHOEN" is set to
Read & Write
YES; "BET3GHOEN" is set to YES; the
RSCP of the 3G cell for a period of
time is greater than the sun of
"HORSCPTH3G" and "RSCPOFF".

Cell

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Cell

None

Read & Write

Transport channel

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Transport channel

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

SCCP

When the value of "SPCBITS" is set


to BIT14 or BIT24, this parameter is
valid.

Read & Write

PPP link

None

Read & Write

Cell

This parameter is valid only when


"EMCPRILV" in "SET GCELLCCAD" is
not set to 15.

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

MSP protect group

None

Read & Write

SCCP

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

SCTP link

None

Read & Write

SCTP link

None

Read & Write

SCTP link

The value to be set should be larger


than the value of "RTOMIN" in "ADD
Read & Write
SCTPLNK" but smaller than the
value of "RTOMAX".

SCTP link

The value to be set should be larger


than the value of "RTOMIN" in "ADD Read & Write
SCTPLNK".

SCTP link

The value to be set should be


smaller than the value of "RTOMAX" Read & Write
in "ADD SCTPLNK".

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

IP logical port

None

Read & Write

IP logical port

None

Read & Write

BTS

None

Read & Write

IP path

None

Read & Write

Transmission resource group

When "GRPT" in "ADD RSCGRP" is


set to ATM or "BWMODE" is set to
FULL_DUPLEX, this parameter is
valid;The sum of "TxBw" and "RxBw"
in "ADD RSCGRP" of upper class
RSCGRP can not less than the
"TxBw" and "AllBw" in "ADD
RSCGRP"of lower class RSCGRP;The
Read & Write
"TxBw" in "ADD RSCGRP" of upper
class RSCGRP can not less than the
"TxBw" in "ADD RSCGRP" of lower
class RSCGRP, and the "RxBw" in
"ADD RSCGRP" of upper class
RSCGRP can not less than the
"RxBw" in "ADD RSCGRP" of lower
class RSCGRP.

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM1.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

TRX

None

Read & Write

BTS

None

Read & Write

TRX

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

TRX

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

This parameter is required when


"Default DPC" is set to NO.

Read & Write

Cell

This parameter is valid only when


"PWRBCDALLOWD" is set to YES.

Read & Write

Cell

This parameter is valid only when


"SAICALLOWED" in "SET
GCELLPWRBASIC" is set to YES.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"TURNOFFENABLE" is set to YES.

Read & Write

Cell

This parameter is valid only when


"TURNOFFENABLE" is set to YES.

Read & Write

Cell

1. This parameter is valid only when


"TURNOFFENABLE" is set to ENABLE.
2. The setting of
this parameter must meet the
Read & Write
following condition:
"SAMECVGCELLLOADSTATTM" >=
"SAMECVGCELLLOADLASTTM".

Cell

This parameter is valid only when


"TURNOFFENABLE" is set to YES.

Read & Write

Cell

This parameter is valid only when


"TURNOFFENABLE" is set to YES.

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"QUICKHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

SCTP link

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

MSP protect group

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

MSP protect group

None

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

MSP protect group

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

The value of this parameter must be


smaller than "DC Voltage Lower
Read & Write
Threshold".

Cell

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

MSC

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

The value range of this parameter


varies with "BTS Type". Different
types of BTSs support different
types of services.

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

This parameter is valid when


"SGSNPOOLALLOW" is set to YES.

Read & Write

BSC

This parameter is valid when


"SGSNPOOLALLOW" is set to YES.

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BTS

This parameter is valid only when


the cell parameter
"BAKPWRSAVMETHOD" is set to
BYPWR and "SDFALG" in "SET
GTRXDEV" is set to ENABLE.

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

SCCP

None

Read & Write

SCCP

None

Read & Write

BSC6900

None

Read & Write

NSE

None

Read & Write

NSE

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Ethernet port

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

SCCP

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

None

The number of CPU usage sampling


times is at least twice the size of
Read & Write
"Fast judgement window".

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Board

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

Transmission resource group

None

Read & Write

E1/T1 link

None

Read & Write

E1/T1 link

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

Transmission resource group

None

Read & Write

Transmission resource group

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

TRX

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

SCCP

When the value of "SPDF" is set to


WNF, this parameter is valid.

Read & Write

SCCP

This parameter depends on network


Read & Write
planning.

SCCP

When the value of "SPDF" is set to


DNF, this parameter is valid.

Read & Write

PBE1T1

None

Read & Write

SCCP

When the value of "SPDF" in "ADD


N7DPC" is set to WNF, this
parameter is valid.

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

MSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Ethernet port

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu.

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu.

Read & Write

BSC

None

Read & Write

BSC6900

This parameter is required when


"Trunking MSC" is set to YES.

Read & Write

BSC

This parameter is valid only when


"TYPE" in "SET BSCPCUTYPE" is set
to OUTER.

Read & Write

BSC

This parameter is valid only when


"TYPE" in "SET BSCPCUTYPE" is set
to OUTER.

Read & Write

BSC

This parameter is valid only when


"TYPE" in "SET BSCPCUTYPE" is set
to OUTER.

Read & Write

BSC

This parameter is valid only when


"TYPE" in "SET BSCPCUTYPE" is set
to OUTER.

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu.

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

SCCP

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

The value of this parameter must be


the same as that of
Read & Write
"HOCTRLSWITCH" in "SET
GCELLHOBASIC".

Current BFD session

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Ethernet port

None

Read & Write

Cell

None

Read & Write

E1/T1 port

None

Read & Write

None

None

Read & Write

E1/T1 port

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

E1/T1 link

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Control plane link

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

NSE

None

Read & Write

NSE

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

E1/T1 link

When the value of "OPMODE" of


"BLK ACIC" is BYCICRANGE, the
value of STARTTS needs to be set.

Read & Write

PBCIC

None

Read & Write

BSC

The setting of this parameter must


meet the following condition: When
"EndMonthDSTPA" and
"StartMonthDSTPA" are set to the
same value, "EndDayDSTPA" must
be later than "StartDayDSTPA".

Read & Write

BTS

The value of this parameter must be


smaller than "Heater shutdown
Read & Write
Temperature".

BSC

The setting of this parameter must


meet the following condition:
Read & Write
"EndMonthDSTPA" is the same as or
is later than "StartMonthDSTPA".

BSC

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

This parameter is valid only when


"ENABLE" is set to YES.

Read & Write

BSC

This parameter is set only when


"BSCDynSwitchTrxPAAllow" is set to
YES.

Read & Write

E1/T1 link

When the value of "OPMODE" of


"BLK AE1T1" is BYCICRANGE, the
value of STARTTS needs to be set.

Read & Write

E1/T1 link

When the value of "OPMODE" of


"BLK ATERE1T1" is BYCICRANGE, the Read & Write
value of STARTTS needs to be set.

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

E1/T1 link

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC

To ensure that all the frequencies


can be measured within 24 hours,
the following condition must be met:
Read & Write
("PERIOD" x 15) x (total number of
frequencies to be measured/"STEP")
< (24 x 60).

MTP3 link

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

This parameter is valid only when


"ENABLE" is set to YES.

Read & Write

SCCP

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

If the added monitoring timeslot


works at 64 kbit/s, the sub-timeslots
are numbered from 0. If the added
monitoring timeslot works at 32
kbit/s, the sub-timeslots are
numbered from 0 or 4. If the added
monitoring timeslot works at 16
Read & Write
kbit/s, the sub-timeslots are
numbered from 0, 2, 4, or 6. If the
added monitoring timeslot works at
8 kbit/s, the sub-timeslots are
numbered from any value among 0
to 7.

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

If "Work Mode for Auto Download


Activation" is "TMUAUTOACT", the
BTS type must be consistent with
the actual BTS type.

Read & Write

E1/T1 link

When SUBBSC is selected for "BSC


flag", this parameter should be set.

Read & Write

E1/T1 link

When SUBBSC is selected for "BSC


flag", this parameter should be set.

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

This parameter must meet the


following requirements: The sum of
the value of "Max Subframe Length" Read & Write
and 8 must be smaller than the
value of "Maximum Frame Length".

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid when


"FLEXABISMODE" in the "MOD BTS"
command is set to YES.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu.

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"GPRS" is set to SupportAsInnPcu
and "SUPPORTDTM" is set to
SUPPORT.

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

NSE

None

Read & Write

NSE

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

SCTP link

None

Read & Write

SCTP link

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


"UTRANCELLTYPE" is set to TDD.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

Cell

This parameter is valid only when


"LOADHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

None

None

Read & Write

BSC

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

MTP3 link

None

Read & Write

MTP3 link

None

Read & Write

MTP3 link

None

Read & Write

MTP3 link

None

Read & Write

MTP3 link

None

Read & Write

MTP3 link

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BTS

The value of this parameter must be


Read & Write
smaller than "T203".

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

The value of this parameter must be


Read & Write
greater than "T200".

MTP3 link

None

Read & Write

MTP3 link

None

Read & Write

MTP3 link

None

Read & Write

None

The value of this parameter must be


Read & Write
smaller than or equal to "Time2[S]".

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BC

None

Read & Write

MTP3 link

None

Read & Write

BSC

None

Read & Write

MTP3 link

None

Read & Write

BSC

None

Read & Write

MTP3 link

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

MTP3 link

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" is set to
HOALGORITHM2 and "TAHOEN" is
set to YES. The following condition
must be met: "TASTATTIME" >=
"TALASTTIME".

Read & Write

Cell

This parameter is valid only when


"TAHOEN" in "SET GCELLHOBASIC"
is set to YES.

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"HOCTRLSWITCH" in "SET
GCELLHOBASIC" is set to
HOALGORITHM2.

Read & Write

BSC6900

None

Read & Write

Cell

This parameter is valid only when


"TAHOEN" is set to YES and
"HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"TASTATTIME" >= "TALASTTIME".

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell. The following
condition must be met: "TALIMIT" >
"TATHRES".

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BTS

This parameter is valid only when


"OMLBKUP" is set to YES.

Read & Write

BTS

This parameter must meet the


following requirements: "FallBack
Start Time" > "Ring I Wait Time
Read & Write
Before Switch" + "Ring I Try Rotating
Duration Time".

MTP3 link

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

TRX

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

"TCHTRICBUSYOVERLAYTHR" and
"TCHTRIBUSYUNDERLAYTHR" can be
set only when
Read & Write
"HRIUOLDRATESELALLOW" is set to
YES.

Cell

"TCHTRICBUSYOVERLAYTHR" and
"TCHTRIBUSYUNDERLAYTHR" can be
set only when
Read & Write
"HRIUOLDRATESELALLOW" is set to
YES.

MTP3 link

None

Read & Write

MTP3 link

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Control plane link

None

Read & Write

Cell

None

Read & Write

Control plane link

None

Read & Write

Control plane link

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Control plane link

None

Read & Write

Control plane link

None

Read & Write

PBSL

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

This parameter must be at least 3C


greater than "Lower ENV TEMP
Alarm".

Read & Write

BTS

This parameter must be at least 4C


greater than "Lower ENV TEMP
Alarm".

Read & Write

BTS

This parameter must be at least 3C


lower than "Upper ENV TEMP
Alarm".

Read & Write

BTS

This parameter must be at least 4C


lower than "Upper ENV TEMP
Alarm".

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

The maximum length of this


parameter is decided by "SCHEME":
When "SCHEME" is set to BINARY,
the length of this parameter should Read & Write
not extend 2462 bytes; otherwise,
the length should not extend 1395
bytes.

Board

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"TIGHTBCCHSWITCH" in "SET
GCELLCHMGBASIC" is set to ON.

Read & Write

Cell

This parameter is valid only when


"TIGHTBCCHSWITCH" in "SET
GCELLCHMGBASIC" is set to ON.

Cell

This parameter is valid only when


"TIGHTBCCHSWITCH" in "SET
GCELLCHMGBASIC" is set to ON. The
Read & Write
following condition must be met:
"TIGHTBCCHHOSTATTIME" >=
"TIGHTBCCHHOLASTTIME".

Cell

This parameter is valid only when


"TIGHTBCCHSWITCH" in "SET
GCELLCHMGBASIC" is set to ON.

Cell

This parameter is valid only when


"TIGHTBCCHSWITCH" in "SET
GCELLCHMGBASIC" is set to ON. The
Read & Write
following condition must be met:
"TIGHTBCCHHOSTATTIME" >=
"TIGHTBCCHHOLASTTIME".

Cell

This parameter is valid only when


"TIGHTBCCHSWITCH" in "SET
GCELLCHMGBASIC" is set to ON.

Read & Write

Cell

None

Read & Write

Read & Write

Read & Write

Cell

None

Read & Write

BSC

This parameter is valid when


"MSCPOOLALLOW" is set to YES.

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

BTS

None

Read & Write

Ethernet port

None

Read & Write

None

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

Cell

None

Read & Write

Ethernet port

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Cell

None

Read & Write

BSC

This parameter is valid when


"MSCPOOLALLOW" is set to YES.

Read & Write

BSC6900

None

Read & Write

Subsystem

This parameter is valid only when


"IDXTYPE" is set to BYTLLI.

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

The value of this parameter must be


at least two degrees smaller than
Read & Write
"Temperature Alarm Upper
Threshold".

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

The TRMMAP index is configured by


setting the value of "TMI" in "ADD
TRMMAP".

Read & Write

BC

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

MTP3 link

None

Read & Write

MTP3 link

None

Read & Write

BSC6900

None

Read & Write

PBE1T1

None

Read & Write

ATERCONSL

None

Read & Write

Cell

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

SCCP

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

IP path

None

Read & Write

BSC6900

When the value of "ITFT" in "ADD


TRMMAP" is set to IUB, IUR or IUCS,
this parameter is valid.

Read & Write

BSC6900

When the value of "ITFT" in "ADD


TRMMAP" is set to IUB, IUR or IUCS,
this parameter is valid.

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"LOADHOEN" in "SET
GCELLHOBASIC" is set to YES.

Read & Write

Ethernet port

None

Read & Write

BSC6900

None

Read & Write

Ethernet port

None

Read & Write

BSC6900

None

Read & Write

PPP link

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

IP logical port

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

None

The TRM load threshold parameter


must meet the following conditions:
forward congestion recovery
Read & Write
threshold < logical port bandwidth,
backward congestion recovery
threshold < logical port bandwidth.

BTS

None

Read & Write

Ethernet port

None

Read & Write

None

None

Read & Write

IP logical port

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

Physical channel

None

Read & Write

TRX

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

Physical channel

None

Read & Write

TRX

None

Read & Write

BTS

None

Read & Write

TRX

None

Read & Write

TRX

None

Read & Write

Cell

None

Read & Write

TRX

None

Read & Write

E1/T1 link

When the value of "OPMODE" of


"BLK AE1T1" is BYCICVALUE, the
value of TS needs to be set.

Read & Write

E1/T1 link

When the value of "OPMODE" of


"BLK ATERE1T1" is BYCICVALUE, the
value of TS needs to be set.

Read & Write

BC

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

PPP link

None

Read & Write

MP link

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

E1/T1 port

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

PBSL

None

Read & Write

Physical channel

None

Read & Write

TRX

None

Read & Write

BSC

The value of "Fast Flux


Measurement Period" cannot be
greater than that of "Fast Flux
Measurement TBF Time".

Read & Write

BSC

None

Read & Write

BTS

If this parameter is set to 16K, "InBSC Sub Timeslot No." and "Out-BTS
Sub Timeslot No." must be 0, 2, 4, or
6. If this parameter is set to 32K,
"In-BSC Sub Timeslot No." and "Out- Read & Write
BTS Sub Timeslot No." must be 0 or
4. If this parameter is set to 64K,
"In-BSC Sub Timeslot No." and "OutBTS Sub Timeslot No." must be 0.

BTS

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

Cell

This parameter is valid only when


Read & Write
"TURNOFFENABLE" is set to ENABLE.

Cell

When "TURNOFFCELLSTPTIME" <


"TURNOFFCELLSTRTIME", it indicates
that the Dynamic Cell Power Off
Read & Write
feature can be enabled for more
than a day.

Cell

This parameter is valid only when


"TURNOFFENABLE" is set to ENABLE
or SLEEPING. The following condition
Read & Write
must be met:
"TURNOFFCELLSTPTIME" <
"TURNOFFCELLSTRTIME"..

Cell

None

Cell

This parameter is valid only when


Read & Write
"TURNOFFENABLE" is set to ENABLE.

BTS

The value of this parameter must be


smaller than "Temperature Alarm
Read & Write
Lower Threshold".

BTS

The value of this parameter must be


at least two degrees greater than
Read & Write
"Temperature Alarm Lower
Threshold".

BSC6900

None

Read & Write

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

Board

None

Read & Write

IP path

None

Read & Write

Transmission resource group

When "GRPT" in "ADD RSCGRP" is


set to ATM or "BWMODE" is set to
FULL_DUPLEX, this parameter is
valid;The sum of "TxBw" and "RxBw"
in "ADD RSCGRP" of upper class
RSCGRP can not less than the
"TxBw" and "AllBw" in "ADD
RSCGRP"of lower class RSCGRP;The
Read & Write
"TxBw" in "ADD RSCGRP" of upper
class RSCGRP can not less than the
"TxBw" in "ADD RSCGRP" of lower
class RSCGRP, and the "RxBw" in
"ADD RSCGRP" of upper class
RSCGRP can not less than the
"RxBw" in "ADD RSCGRP" of lower
class RSCGRP.

Cell

None

Read & Write

Ethernet port

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

BTS

The value range of this parameter


varies with BTS type. Different types
Read & Write
of BTSs support different types of
cabinets.

Cell

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

MSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

MSC

None

Read & Write

None

None

Read & Write

None

None

Read & Write

NSE

None

Read & Write

NSE

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

E1/T1 port

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "ULAFSREXQUALHIGHTHRED"
>= "ULAFSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "ULAFSREXQUALHIGHTHRED"
>= "ULAFSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "ULAHSREXQUALHIGHTHRED"
>= "ULAHSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "ULAHSREXQUALHIGHTHRED"
>= "ULAHSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"BETTERCELLHOEN" is set to YES
and "HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"ULBQSTATTIME" >=
"ULBQLASTTIME".

Read & Write

Cell

This parameter is valid only when


"BETTERCELLHOEN" is set to YES
and "HOCTRLSWITCH" is set to
HOALGORITHM2. The following
condition must be met:
"ULBQSTATTIME" >=
"ULBQLASTTIME".

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid when


"FRINGEHOEN" is set to YES or
"RXQCKFALLHOEN" is set to YES.

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLOPTIMIZEDEN" is set to
YES.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "ULFSREXQUALHIGHTHRED"
>= "ULFSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "ULFSREXQUALHIGHTHRED"
>= "ULFSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "ULHSREXQUALHIGHTHRED"
>= "ULHSREXQUALLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "ULHSREXQUALHIGHTHRED"
>= "ULHSREXQUALLOWTHRED".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
Read & Write
"ULTHF1" + "ULHYSTF1" < "ULTHF2"
+ "ULHYSTF2".

Cell

The setting of this parameter must


meet the following condition:
Read & Write
"ULTHF2" + "ULHYSTF2" < "ULTHF3"
+ "ULHYSTF3".

Cell

None

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"ULTHH1" + "ULHYSTH1" <
"ULTHH2" + "ULHYSTH2".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"ULTHH2" + "ULHYSTH2" <
"ULTHH3" + "ULHYSTH3".

Read & Write

Cell

None

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"ULTHWB1" + "ULHYSTWB1" <
"ULTHWB2" + "ULHYSTWB2".

Read & Write

Cell

The setting of this parameter must


meet the following condition:
"ULTHWB1" + "ULHYSTWB1" <
"ULTHWB2" + "ULHYSTWB2".

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2
and "UPPCEN" in "SET
GCELLBASICPARA" is set to YES.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

BSC

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2
and "UPPCEN" in "SET
GCELLBASICPARA" is set to YES.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "ULQLOWTHRED" >=
"ULQHIGHTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "ULQLOWTHRED" >=
"ULQHIGHTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2
and "UPPCEN" in "SET
GCELLBASICPARA" is set to YES.

Read & Write

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid when


"PWRCTRLSW" in the "SET
Read & Write
GCELLPWRBASIC" command is set to
PWR2.

Cell

This parameter is valid only when


"BQHOEN" in "SET GCELLHOBASIC"
Read & Write
is set to YES and "NODLMRHOEN" in
"SET GCELLHOEMG" is set to YES.

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "ULREXLEVHIGHTHRED" >=
"ULREXLEVLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.
The following condition must be
met: "ULREXLEVHIGHTHRED" >=
"ULREXLEVLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR3.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLOPTIMIZEDEN" is set to
YES.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLOPTIMIZEDEN" is set to
YES.

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "ULSSHIGHTHRED" >=
"ULSSLOWTHRED".

Read & Write

Cell

This parameter is valid only when


"PWRCTRLSW" in "SET
GCELLPWRBASIC" is set to PWR2.
The following condition must be
met: "ULSSHIGHTHRED" >=
"ULSSLOWTHRED".

Read & Write

Cell

The setting of this parameter must


meet the following conditions:
"ULTHF1" < "ULTHF2";

Read & Write

"ULTHF1" + "ULHYSTF1" < "ULTHF2"


+ "ULHYSTF2".

Cell

The setting of this parameter must


meet the following conditions:
"ULTHF2" < "ULTHF3";

Read & Write

"ULTHF2" + "ULHYSTF2" < "ULTHF3"


+ "ULHYSTF3".

Cell

The setting of this parameter must


meet the following conditions:
"ULTHF2" < "ULTHF3";
"ULTHF2" + "ULHYSTF2" < "ULTHF3"
+ "ULHYSTF3".

Read & Write

Cell

The setting of this parameter must


meet the following conditions:
"ULTHH1" < "ULTHH2";

Read & Write

"ULTHH1" + "ULHYSTH1" <


"ULTHH2" + "ULHYSTH2".

Cell

The setting of this parameter must


meet the following conditions:
"ULTHH2" < "ULTHH3";

Read & Write

"ULTHH2" + "ULHYSTH2" <


"ULTHH3" + "ULHYSTH3".

Cell

The setting of this parameter must


meet the following conditions:
"ULTHH2" < "ULTHH3";

Read & Write

"ULTHH2" + "ULHYSTH2" <


"ULTHH3" + "ULHYSTH3".

Cell

The setting of this parameter must


meet the following conditions:
"ULTHWB1" < "ULTHWB2";

Read & Write

"ULTHWB1" + "ULHYSTWB1" <


"ULTHWB2" + "ULHYSTWB2".

Cell

The setting of this parameter must


meet the following conditions:
"ULTHWB1" < "ULTHWB2";

Read & Write

"ULTHWB1" + "ULHYSTWB1" <


"ULTHWB2" + "ULHYSTWB2".

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

BSC

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

Generally, the value of this


parameter is equal to "A Interface
Tag" and "Abis Interface Tag".

Read & Write

E1/T1 port

None

Read & Write

BSC

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

This parameter is valid only when


"EGPRS2A" is set to YES.

Read & Write

Cell

This parameter is valid only when


"EGPRS2A" is set to YES.

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BTS

This parameter is valid only when


"ENABLE" is set to YES.

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Transmission resource group

When "ISFIRSTCLASSE" in "ADD


RSCGRP" is set to NO, this
parameter is valid.

Read & Write

None

None

Read & Write

Cell

The following condition must be


met: "UPRXLEVSTATICTIME" >=
"UPRXLEVLASTTIME".

Read & Write

Cell

None

Read & Write

Cell

The following condition must be


met: "UPRXLEVSTATICTIME" >=
"UPRXLEVLASTTIME".

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

BTS

None

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
Concentric_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

This parameter is valid only when


"IUOTP" in "ADD GCELL" is set to
EDB_cell.

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

Cell

"VGCSRSRVNUM"" <=
"VGCSMAXNUM"

Read & Write

Cell

None

Read & Write

Cell

"VGCSRSRVNUM"" + PDTCH Number


Read & Write
<= Cell total service Channels

BSC

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

IP path

None

Read & Write

BSC6900

None

Read & Write

SCTP link

None

Read & Write

SCTP link

None

Read & Write

BSC6900

None

Read & Write

BTS

This parameter is valid only when


"VLANSWITCH" is set to YES.

Read & Write

Ethernet port

None

Read & Write

Ethernet port

None

Read & Write

BSC6900

None

Read & Write

BSC6900

None

Read & Write

BTS

This parameter is valid only when


"VLANSWITCH" is set to YES.

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

None

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

BTS

This parameter must be at least 0.2


smaller than "Serious VSW Alarm
Read & Write
TH".

BTS

This parameter must be at least 0.2


greater than "Standing Wave Radio Read & Write
Alarm Threshold".

Cell

None

Read & Write

BTS

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

Cell

None

Read & Write

BSC

Timer of MS Location Response from


MS<Timer of MS Location Response Read & Write
from SMLC

Cell

None

Read & Write

Cell

None

Read & Write

BSC

Timer of MS Location Response from


MS<Timer of MS Location Response Read & Write
from SMLC

BTS

None

Read & Write

None

None

Read & Write

BSC6900

None

Read & Write

Cell

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

BSC

None

Read & Write

BSC6900

None

Read & Write

SCCP

None

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

TRX

This parameter is valid only when


"WLNKALMFLAG" is set to YES.

Read & Write

TRX

None

Read & Write

BSC6900

None

Read & Write

BTS

None

Read & Write

None

None

Read & Write

E1/T1 port

None

Read & Write

BTS

None

Read & Write

ATERCONSL

None

Read & Write

BTS

This parameter is valid only when


"OMLBKUP" is set to YES.

Read & Write

BTS

This parameter must meet the


following requirements: "FallBack
Start Time" > "Ring I Wait Time
Read & Write
Before Switch" + "Ring I Try Rotating
Duration Time".

MSP protect group

None

Read & Write

BSC6900

None

Read & Write

Service Interrupted After


Modification

Interruption Scope

Interruption
Duration(Min)

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

The services are


disrupted until this
parameter is set to
Unlock.

If the value of this parameter is


modified to "Lock", forced handover
is triggered to hand the ongoing
services on the corresponding TRX
to another TRX. Services will be
disrupted if the handover fails. If
TRX
the value of this parameter is
modified to "Shutdown", the
ongoing services are not affected
but new service accesses are not
allowed.

Services will be
disrupted until the
value of this parameter
is changed to "Unlock".

If the value of this parameter is


modified to "Lock", forced handover
is triggered to hand the ongoing
services on the corresponding
channel to another channel.
Services will be disrupted if the
Channel
handover fails. If the value of this
parameter is modified to
"Shutdown", the ongoing services
are not affected but new service
accesses are not allowed.

Services will be
disrupted until the
value of this parameter
is changed to "Unlock".

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Ethernet port

Interrupt the service


until the correct
gateway is set or the
port swapping or the
changing of IP route is
finished.

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BSC6900

Less than 10 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Less than 5 minutes

PPP link

Interrupt the service


until negotiate
successfully again.

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Less than 5 minutes

BSC6900

Interrupt the service


until negotiate
successfully again.

BSC6900

Interrupt the service


until negotiate
successfully again.

PPP link

Less than 5 minutes

PPP link

Interrupt the service


until negotiate
successfully again.

BSC6900

Interrupt the service


until negotiate
successfully again.

PPP link

Less than 5 minutes

PPP link

Interrupt the service


until negotiate
successfully again.

BSC6900

Interrupt the service


until negotiate
successfully again.

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Optical port

If the mode is not


consistent, will
interrupt service until it
is consistent.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not Involved

IP path

Less than 5 minutes

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

IP path

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Channel

Less than 1 minute

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Less than 10 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (Impact on the UE in idle mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (Impact on the UE in idle mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Less than 5 minutes

BSC6900

Less than 5 minutes

BSC6900

Less than 5 minutes

BSC6900

Less than 5 minutes

BSC6900

Less than 5 minutes

BSC6900

Less than 5 minutes

BSC6900

Less than 5 minutes

BSC6900

Less than 5 minutes

BSC6900

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Less than 10 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not Involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 1 minute

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

NSVC

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Less than 10 minutes

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 10 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 1 minute

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Interrupt the service


until negotiate
successfully again.

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 1 minute

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

Services are disrupted when the


BCCH frequency of a cell is
changed.

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

PS service of the cell


will be interrupt until
this parameter is set to
"SupportAsInnPcu" or
"SupportAsExtPcu.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 10 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 1 minute

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 1 minute

Not involved

Not involved

Not involved

If traffic handover fails after the


modification of the parameter, the
service is interrupted.

Cell

Less than 1 minute

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

The services are


interrupted until the
signaling point is
available.

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 1 minute

Cell

Less than 1 minute

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 1 minute

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not Involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Ethernet port

The loopback keeps


interrupting the
services until the
loopback is cancelled.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

NSE

Services are
interrupted unless the
NSVL configuration is
the same as the SGSN
configuration at the
BSC.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 1 minute

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

If the mode is not


consistent, will
interrupt service until it
is consistent.

BSC6900

If the mode is not


consistent, will
interrupt service until it
is consistent.

BSC6900

If the mode is not


consistent, will
interrupt service until it
is consistent.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

If the mode is not


consistent, will
interrupt service until it
is consistent.

BSC6900

If the mode is not


consistent, will
interrupt service until it
is consistent.

BSC6900

If the mode is not


consistent, will
interrupt service until it
is consistent.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Optical port

If the mode is not


consistent, will
interrupt service until it
is consistent.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

N (No impact on the UE in idle


mode)

Not involved

Not involved

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

E1/T1 port

When the peer end


unconditionally
changes the bits in the
check message, the
services will not
resume unless the
switch is set to OFF.

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

E1/T1 port

The loopback keeps


interrupting the
services until it is
cancelled.

BSC6900

The loopback keeps


interrupting the
services until it is
cancelled.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

IP path

Less than 5 minutes

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

IP path

Less than 5 minutes

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Services are disrupted


until the cells are redistributed successfully.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

PPP link

Less than 5 minutes

PPP link

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BSC6900

If the mode is not


consistent, will
interrupt service until it
is consistent.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

If the mode is not


consistent, will
interrupt service until it
is consistent.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Less than 10 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Ethernet port

If the value is too big,


will interrupt service
until it is set to the
normal value.

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 15 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

BTS

Less than 5 minutes

PPP link

Less than 5 minutes

PPP link

Less than 5 minutes

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

PPP link

Less than 5 minutes

PPP link

Interrupt the service


until negotiate
successfully again.

BSC6900

Interrupt the service


until negotiate
successfully again.

NSE

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (Impact on the UE in idle mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Ethernet port

The loopback keeps


interrupting the
services until the
loopback is cancelled.

Ethernet port

The loopback keeps


interrupting the
services until the
loopback is cancelled.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

BSC6900

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

BTS

Less than 5 minutes

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BC

Services are
interrupted until the
parameter is consistent
with the SGSN at the
peer end.

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

NSE

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

BSC6900

Interrupt the service


until negotiate
successfully again.

BSC6900

Interrupt the service


until negotiate
successfully again.

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

NSE

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

The services are


interrupted until the
signaling point is
available.

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

If the mode is not


consistent, will
interrupt service until it
is consistent.

BSC6900

The services are


interrupted until the
M3DE is available.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Less than 10 minutes

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC

Services are
interrupted until the
parameter is set to
ALLOW or the cell is
configured with a new
SGSN.

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

NSE

Services are
interrupted until
"SIGLW" is not set to 0.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

The services are


interrupted until the
signaling point is
available.

BSC6900

The services are


interrupted until the
signaling point is
available.

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Interrupt the service


until negotiate
successfully again.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Subrack connection path

Less than 5 minutes

Subrack connection path

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

NSE

Services are
interrupted until
"SRVLW" is not set to 0.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC6900

Less than 5 minutes

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Subrack connection path

Less than 5 minutes

Subrack connection path

Less than 5 minutes

BSC

The services are


interrupted until the
PBSL is working
normally.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not Involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

If traffic handover fails after the


modification of the parameter, the
service is interrupted.

Cell

Less than 1 minute

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

N (No impact on the UE in idle


mode)

Cell

Less than 1 minute

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 5 minutes

BTS

Less than 5 minutes

PPP link

Less than 5 minutes

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Cell

Less than 1 minute

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

BSC

The services are


interrupted until the
PBSL is working
normally.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BSC

Less than 30 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

NSE

Services are
interrupted unless the
NSVL configuration is
the same as the SGSN
configuration at the
BSC.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BTS

Less than 5 minutes

BTS

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

IP path

Less than 5 minutes

Not involved

Not involved

Not involved

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

SCTP link

The services are


interrupted until the
SCTP link is working
normally.

BSC6900

If the mode is not set


back, will interrupt
service until it is set
back.

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

Not involved

BSC6900

If the mode is not set


back, will interrupt
service until it is set
back.

BSC6900

If the mode is not set


back, will interrupt
service until it is set
back.

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

BSC6900

Less than 5 minutes

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Not involved

Not involved

Not involved

N (No impact on the UE in idle


mode)

Not involved

Not involved

Caution
None

None

The value of this parameter must be greater than five times the maximum value of the
following parameter: "Filter Length for SDCCH Level", "Filter Length for SDCCH Qual",
"Filter Length for TCH Level", "Filter Length for TCH Qual", "Filter Length for TA", "TA
filter length for SDCCH level". If the parameter "IBCA Allowed" is set to YES, then the
value of this parameter must be greater than five times the value of "IBCA Assign
Waiting Mr Time". If the parameter Waiting for "MR on SDCCH Switch" is set to YES,
then the value of this parameter must be greater than the value of "Duration for
Waiting MR on SDCCH".

None

None

None

None

None

This parameter should be set to ON when the transmission delays of different 64 kbit/s
timeslots are different over the Abis interface in TDM transmission mode. Different
transmission delays usually occur in the DXX network mode or when the transmission
paths of multiple E1 links are different under the same site.

None

None

None

None

None

If this parameter is set too high, a normal voice may be considered abnormal. If this
parameter is set too low, an abnormal voice may not be considered.

None

None

None

None

None

None

None

None

None

None

None

None

This parameter is valid only when "BSSPAGINGCOORDINATION" in "SET GCELLPSBASE"


is set to YES.

ACS is usually set to 0 because system information 7 and 8 messages are seldom used
in common cells. ACS should be set to 1 if system information 7 and 8 messages are
used in a cell and C2 is used for cell reselection.

The number of the chosen data rates must be from one to four. If this parameter
involves only one full rate coding rate, the value of "AMR Starting Mode[F]" can be 0
only; all the adjustable thresholds and hysteresis of AMR coding rate make no sense.
If this parameter involves two coding rates, the value of "AMR Starting Mode[F]" can be
0 or 1; the values of the following parameters make sense while the other adjustable
thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[F]",
"AMR UL Coding Rate adj.hyst1[F]", "AMR DL Coding Rate adj.th1[F]", and "AMR DL
Coding Rate adj.hyst1[F]".
If this parameter involves three coding rates, the value of "AMR Starting Mode[F]" can
be 0, 1, or 2; the values of the following parameters make sense while the other
adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate
adj.th1[F]", "AMR UL Coding Rate adj.hyst1[F]", "AMR DL Coding Rate adj.th1[F]", "AMR
DL Coding Rate adj.hyst1[F]", "AMR UL Coding Rate adj.th2[F]", "AMR UL Coding Rate
adj.hyst2[F]", "AMR DL Coding Rate adj.th2[F]", and "AMR DL Coding Rate
adj.hyst2[F]".
If this parameter involves four full rate coding rates, the value of "AMR Starting
Mode[F]" can be 0, 1, 2, and 3; all the adjustable thresholds and hysteresis of AMR
coding rate make sense.

The number of the chosen data rates must be from one to four. If this parameter
involves only one half rate coding rate, the value of "AMR Starting Mode[H]" can be 0
only; all the adjustable thresholds and hysteresis of AMR coding rate make no sense.
If this parameter involves two coding rates, the value of "AMR Starting Mode[H]" can
be 0 or 1; the values of the following parameters make sense while the other
adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate
adj.th1[H]", "AMR UL Coding Rate adj.hyst1[H]", "AMR DL Coding Rate adj.th1[H]", and
"AMR DL Coding Rate adj.hyst1[H]".
If this parameter involves three coding rates, the value of "AMR Starting Mode[H]" can
be 0, 1, or 2; the values of the following parameters make sense while the other
adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate
adj.th1[H]", "AMR UL Coding Rate adj.hyst1[H]", "AMR DL Coding Rate adj.th1[H]",
"AMR DL Coding Rate adj.hyst1[H]", "AMR UL Coding Rate adj.th2[H]", "AMR UL Coding
Rate adj.hyst2[H]", "AMR DL Coding Rate adj.th2[H]", and "AMR DL Coding Rate
adj.hyst2[H]".
If this parameter involves four half rate coding rates, the value of "AMR Starting
Mode[H]" can be 0, 1, 2, and 3; all the adjustable thresholds and hysteresis of AMR
coding rate make sense.

The number of the chosen data rates must be from one to three. If this parameter
involves only one coding rate, the value of "AMR Starting Mode[WB]" can be 0 only; all
the adjustable thresholds and hysteresis of AMR coding rate make no sense.
If this parameter involves two coding rates, the value of "AMR Starting Mode[WB]" can
be 0 or 1; the values of the following parameters make sense while the other
adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate
adj.th1[WB]", "AMR UL Coding Rate adj.hyst1[WB]", "AMR DL Coding Rate
adj.th1[WB]", and "AMR DL Coding Rate adj.hyst1[WB]".
If this parameter involves three coding rates, the value of "AMR Starting Mode[WB]"
can be 0, 1, or 2; the values of the following parameters make sense while the other
adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate
adj.th1[WB]", "AMR UL Coding Rate adj.hyst1[WB]", "AMR DL Coding Rate
adj.th1[WB]", "AMR DL Coding Rate adj.hyst1[WB]", "AMR UL Coding Rate
adj.th2[WB]", "AMR UL Coding Rate adj.hyst2[WB]", "AMR DL Coding Rate
adj.th2[WB]", and "AMR DL Coding Rate adj.hyst2[WB]".

None

None

None

None

None

None

None

None

None

None

None.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

With a good anti-interference capability, AMR codes can support a lower carrier-tointerference ratio than non-AMR codes in a same FER. When the AMR is enabled, the
voice quality improves. In this case, the value of this parameter can be a little larger
than that of "Radio Link Timeout".
With a good anti-interference capability, AMR codes can support a lower carrier-tointerference ratio than non-AMR codes in a same FER. When the AMR is enabled, the
voice quality improves. In this case, the value of this parameter can be a little larger
than that of "SACCH Multi-Frames".
The parameter cannot be modified.
None

With a good anti-interference capability, AMR codes can support a lower carrier-tointerference ratio than non-AMR codes in a same FER. When the AMR is enabled, the
voice quality improves. In this case, the value of this parameter can be a little larger
than that of "Radio Link Timeout".
With a good anti-interference capability, AMR codes can support a lower carrier-tointerference ratio than non-AMR codes in a same FER. When the AMR is enabled, the
voice quality improves. In this case, the value of this parameter can be a little larger
than that of "SACCH Multi-Frames".
None

None

None

None

None

None

None

If this parameter is set to a greater value, TRX mutual aid may not be triggered
promptly in the case of BCCH TRX failure after a cell has just been initialized. If this
parameter is set to smaller value, mutual aid may be decided mistakenly.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

This parameter is valid only when "SUPPORTEDA" is set to SUPPORT.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.
None
The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

The adjacent node ID must be configured.

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.


This parameter is valid only when "AqmSwitch" is set to OPEN.

This parameter is valid only when "AqmSwitch" is set to OPEN.

This parameter is valid only when "AqmSwitch" is set to OPEN.

This parameter is valid only when "AqmSwitch" is set to OPEN.

This parameter is valid only when "AqmSwitch" is set to OPEN.

This parameter is valid only when "AqmSwitch" is set to OPEN.

None

This parameter is valid only when "AqmSwitch" is set to OPEN.

None

None

None

None

None

None

To modify this parameter, run "STP GATEWAYCHK" first and then "STR GATEWAYCHK".

To modify this parameter, run "STP GATEWAYCHK" first and then "STR GATEWAYCHK".
The parameter cannot be modified.
None
The parameter cannot be modified.
None

None

Before enabling this function, ensure that the parameter "Directed Retry" of the cell is
set to YES. To obtain MRs on the SDCCH as many as possible, set the parameters
"Waiting for MR on SDCCH Switch" and "IBCA Allowed" to YES.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

The parameter cannot be modified.

The parameter cannot be modified.

None

None

The parameter cannot be modified.

None

None

The parameter cannot be modified.

The ATT must be set to the same value for different cells in a same location area. If not,
some MSs after power-on may not act as a called party until they have waited for the
period specified by "T3212".
None

None

None

None

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
None

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
Negotiation can succeed only when the configuration is consistent on the local and
peer ends.

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
Negotiation can succeed only when the configuration is consistent on the local and
peer ends.

The port can be set to the DOWN or UP state when this parameter is modified. If the
negotiation modes on the local and peer end are not consistent, the service can be
interrupted.

None

None

None

If this parameter is set to YES, the BSC load is increased early in every morning.
The auto negotiation mode of FE port on the IP-based interface board should be
consistent with that of the port on the peer end. Otherwise, this may cause the packet
loss and link disconnection.

None

None

None

If the mode is not consistent, will interrupt service until it is consistent.

None

None

None

None

None

None

None

Each backplane board 8K clock has only one clock source. You are not allowed to turn
on the same backplane board 8K clock switch for multiple interface boards.
Each backplane board 8K clock has only one clock source. You are not allowed to turn
on the same backplane board 8K clock switch for multiple interface boards.
None

None

None

None

None

To modify this parameter, run "STP GATEWAYCHK" first and then "STR GATEWAYCHK".

To modify this parameter, run "STP GATEWAYCHK" first and then "STR GATEWAYCHK".

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter modification should be negotiated with the peer end, and the BSC6900
should be reset after the modification. It is recommended that this parameter should
not be modified when the system is running.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

To disable the alarm blink filter function, set this parameter to "0". To enable the alarm
blink filter function, set this parameter to a value greater than 0 and turn on the alarm
blink filter switch. See "SET ALMBLKSW" for setting the alarm blink filter switch.
To enable the alarm blink filter function, set "Alarm switch of blinking filter" and "Switch
of stat blinking alarm" to "ENABLE".

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.


If the value of this parameter is too small, the SCUs of the TC subrack may remain
congested. If the value is too large, the call failure rate may retain a higher value for a
longer time.

The parameter cannot be modified.

None

None

None

None

None

When the M900/M1800 BSC is upgraded to BSC6000, this parameter needs to be set to
69. If this parameter is not set to 69 in this case, the handover algorithm supported by
this parameter is invalid.

None

None

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.
None

None

None

None

None

None

None

None

None
As defined in the protocol, the value of this parameter cannot be 0 in the following
cases:
The BSC needs to send system messages over the extended BCHs.
CBCHs are configured.
When the GSMR is enabled, NCHs are configured.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

If "MR.Preprocessing" is set to BTS_Preprocessing and this parameter is set to NO, the


uplink-downlink balance associated traffic statistics is improper. In addition, the
handover algorithms that require power compensation are improper, such as PBGT
handover, load handover, and concentric cell handover.

None

A paging block (four continuous CCCH timeslots) can bear two IMSI paging messages,
four TMSI paging messages, or two AGCH immediate assignment message. If the
signaling downlink is faulty when an MS is idle, the rule of downlink failure is based on
the signaling downlink failure counter DSC. When an MS stays in a cell, the DSC is
initialized as an integer the closest to 90/N ("N" is BS_PA_MFRMS, number of
multiframes in a cycle on a paging sub-channel, whose value range is 2 to 9.) When
the MS tries to encode the messages over its paging sub-channels: Every time the MS
succeeds in encoding a message, the DSC increases by 1 but cannot exceed the
initially set value; if the MS fails in encoding a message, the DSC decreases by 4. If the
DSC is smaller than or equal to 0, a signaling downlink failure occurs, which causes cell
reselection. The value of this parameter varies with the BTS types.

None

None

None

None

This parameter is valid on a per cell basis and is valid only when
"ACOOPERATPAGINGSWITCH" in the "SET BSCPSSOFTPARA" command is set to YES.

None

None

None
If certain link is occupied, conversion from E1 to T1 or from T1 to E1 cannot be
performed.
None
The parameter cannot be modified.
The parameter cannot be modified.
The parameter cannot be modified.
None

The parameter cannot be modified.

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

None

None

If BTS Bar Code is incorrect, the OML between the BTS and the BSC cannot be
established. In this case, no alarm or status is displayed. When the BBU or BTS3900E
module of a BTS is replaced, you need to set a new BTS bar code for the BTS on the
BSC.
None

None

This parameter cannot contain #.

None

None

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

None

None

None

None

This parameter can be set to BTS_Preprocessing only when the BTS supports the
configured power control algorithm.

None

The parameter cannot be modified.

None

This parameter is required only by BTSs in IP transmission mode.

None

None

For a double-transceiver BTS or an NGBTS, the initial value is ON. For a BTS of any
other type, the initial value is OFF and unconfigurable.
None

None

The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

None

None

None

The parameter cannot be modified.

None

None

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.


The parameter cannot be modified.
The parameter cannot be modified.
None

None

None

None

None

None

None

None

None
The parameter cannot be modified.

None

None

None

None

None

None
The parameter cannot be modified.
The parameter cannot be modified.

If the value of "Cell Bar Access" is YES and the value of "Cell Bar Qualify" is NO, new
call access is prohibited but handover access is allowed.

The parameter cannot be modified.


None

None

None

None

If the value of "Cell Bar Access" is YES and the value of "Cell Bar Qualify" is NO, new
call access is prohibited but handover access is allowed.

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.

None

None

None

None

None

None

None

This parameter applies to only the EDGE trx.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The setting of this parameter needs negotiation with the opposite network element
MSC.
If the MSC supports processing assignment complete messages containing cell lists, set
this parameter to YES; otherwise, set this parameter to NO.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The congestion start threshold must be greater than the congestion end threshold.

The congestion start threshold must be greater than the congestion end threshold.

None

None

None

The congestion start threshold must be greater than the congestion end threshold.

The congestion start threshold must be greater than the congestion end threshold.

The congestion start threshold must be greater than the congestion end threshold.

None

None

None

None

This function can be activated only when the "Switch for Abis Timeslot Detection" is
"ON".

None

None

None

The purpose of setting this parameter is to avoid call connection failure when an MS
supporting the full rate channel only requests a half rate channel or an MS supporting
the half rate channel only requests a full rate channel. In this way, the BSC can easily
interconnect with an MSC of another vendor.

None

When the network status is poor, the check count should not be too small. Otherwise,
the path state is affected.

None

None

None

The parameter cannot be modified.


None

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

The checksum mode need the negotiation with the peer. According to the RFC4960, the
value should be set to CRC32.

The checksum mode need the negotiation with the peer. According to the RFC4960, the
value should be set to CRC32.

None

The parameter cannot be modified.


None
This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.
None

None

None

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.

The setting of this parameter needs negotiation with the opposite network element
MSC.
If the MSC supports processing assignment complete messages containing the Chosen
Channel, set this parameter to YES; otherwise, set this parameter to NO.
The setting of this parameter needs negotiation with the opposite network element
MSC.
If the MSC supports processing handover performed messages containing the Chosen
Channel, set this parameter to YES; otherwise, set this parameter to NO.
The setting of this parameter needs negotiation with the opposite network element
MSC.
If the MSC supports processing HO REQ ACK messages containing the Chosen Channel,
set this parameter to YES; otherwise, set this parameter to NO.
The setting of this parameter needs negotiation with the opposite network element
MSC. In this way, the MSC can process encryption complete messages correctly.
The setting of this parameter needs negotiation with the opposite network element
MSC. In this way, the MSC can process handover performed messages correctly.
The setting of this parameter needs negotiation with the opposite network element
MSC. In this way, the MSC can process assignment complete messages correctly. An
assignment complete message contains the Chosen Encryption Algorithm only when
the encryption algorithm used by an MS in two cells changes before and after a direct
retry and the value of this parameter is YES.

The setting of this parameter needs negotiation with the opposite network element
MSC.
SENDING: The HO REQ ACK message contains the Chosen Encryption Algorithm.
NOSENDING: The HO REQ ACK message does not contain the Chosen Encryption
Algorithm.
SYSTEMOPT: If the encryption algorithm used by an MS in two cells changes before and
after a handover, the HO REQ ACK message contains the Chosen Encryption Algorithm;
otherwise, the message does not.

None

None

None

None

The smaller the value of this parameter is, the more sensitively the BSC controls the
arrival rate of channel request messages, and vice versa.

None

None

The CI can be input in hexadecimal format. The hexadecimal format is H'****, for
example, H'1214.

1. The block of A interface must be configured.


2. If A over IP is configured, the configuration does not support the operation.

The parameter cannot be modified.

None

None

None

None

None
The setting of this parameter needs negotiation with the opposite network element
MSC. In this way, the MSC can process assignment complete messages correctly.
The setting of this parameter needs negotiation with the opposite network element
MSC. In this way, the MSC can process HO FAIL messages correctly.

The setting of this parameter needs negotiation with the opposite network element
MSC. In this way, the MSC can process assignment failure messages correctly.
NOSENDING: The assignment failure message does not contain the Circuit Pool List.
SENDINGPRO: If the cause value of assignment failure is "Circuit pool mismatch" or
"Switch circuit pool", the assignment failure message contains the Circuit Pool List;
otherwise, the message does not.
SENDING: The assignment failure message contains the Circuit Pool List without
restriction.

The setting of this parameter needs negotiation with the opposite network element
MSC. In this way, the MSC can process HO FAIL messages correctly.

The setting of this parameter needs negotiation with the opposite network element
MSC.
If the MSC does not support process assignment complete messages containing the
Circuit Pool, the value YES of this parameter makes no sense.
The setting of this parameter needs negotiation with the opposite network element
MSC.
If the MSC does not support process assignment complete messages containing the
Circuit Pool, the value YES of this parameter makes no sense.
None

None

None

None

None

None

None

None

None
If you want to modify the value of "Clock board type" from "GCGa" to "GCUa", the
board must not be configured with GPS.

None

None

None

None

None

None

None
The parameter cannot be modified.

None

None

None

None

None

None

None

None

The value of this parameter cannot be changed.

None

None

None

None

None

None

1. If you set "Upper count threshold of raised fault" and "Lower count threshold of
raised fault" to "0", the accumulated number of blink times for the alarm is counted but
not reported.
2. If "Upper count threshold of raised fault" is not "0", the value of "Lower count
threshold of raised fault" cannot be "0" and you must ensure that "Upper count
threshold of raised fault" is greater than "Lower count threshold of raised fault".
3. When "Upper count threshold of raised fault" is not "0" and "Alarm switch of blinking
filter" and "Switch of stat blinking alarm" are "ENABLE", you cannot set "Alarm blink
threshold" to "0". Otherwise, blink statistics of the alarm is not performed.

1. If you set "Upper count threshold of raised fault" and "Lower count threshold of
raised fault" to "0", the accumulated number of blink times for the alarm is counted but
not reported.
2. If "Lower count threshold of raised fault" is not 0, the value of "Upper count
threshold of raised fault" cannot be 0 and you must ensure that "Lower count threshold
of raised fault" is smaller than "Upper count threshold of raised fault".
3. When "Upper count threshold of raised fault" is not "0" and "Alarm switch of blinking
filter" and "Switch of stat blinking alarm" are "ENABLE", you cannot set "Alarm blink
threshold" to "0". Otherwise, blink statistics of the alarm is not performed.

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

None

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

None

This parameter cannot be set to YES for the TRX that carries the main BCCH.

None

This parameter is not supported by the BTS3001C and BTS3001CP.

None

None

None

None

None

The settings of RXLEV-ACCESS-MIN and CRO should guarantee that cells with same
priority have the same cell reselect offset.

None

The parameter is related to practical networking.

None

None

None

None
The modification of the parameter affects the adjacent node that is configured with the
factor table. After the successful modification, the parameter takes effect in the
following two cases:
1. New access subscriber.
2. Bandwidth modification of the existing subscriber
The modification of the parameter affects the adjacent node configured with the
TRMMAP. After the successful modification, it is valid in the case of the new access of a
subscriber and the bandwidth modification of an existing subscriber.

The modification of the parameter affects the adjacent node configured with the
TRMMAP. After the successful modification, it is valid in the case of the new access of a
subscriber and the bandwidth modification of an existing subscriber.
The modification of the parameter affects the adjacent node that is configured with the
factor table. After the successful modification, the parameter takes effect in the
following two cases:
1. New access subscriber.
2. Bandwidth modification of the existing subscriber
The larger the value of this parameter, the higher the proportion of discarded
messages during congestion. Therefore, the priority value of a more important service
must be less than that of a less important service.
None

None

None

None

None

None

None

None

None
The modification of the parameter affects the adjacent node that is configured with the
factor table. After the successful modification, the parameter takes effect in the
following two cases:
1. New access subscriber.
2. Bandwidth modification of the existing subscriber
None

The modification of the parameter affects the adjacent node configured with the
TRMMAP. After the successful modification, it is valid in the case of the new access of a
subscriber and the bandwidth modification of an existing subscriber.

The modification of the parameter affects the adjacent node configured with the
TRMMAP. After the successful modification, it is valid in the case of the new access of a
subscriber and the bandwidth modification of an existing subscriber.
The modification of the parameter affects the adjacent node that is configured with the
factor table. After the successful modification, the parameter takes effect in the
following two cases:
1. New access subscriber.
2. Bandwidth modification of the existing subscriber
The larger the value of this parameter, the higher the proportion of discarded
messages during congestion. Therefore, the priority value of a more important service
must be less than that of a less important service.
None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.
If this parameter of an activated BTS is modified, the entire BTS chain is reset.

If this parameter of an activated BTS is modified, the entire BTS chain is reset.

None
The setting of this parameter needs negotiation with the opposite network element
MSC. In this way, the MSC can process HO RQD messages correctly.
None
None
None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

When running this command, the source IP address and the destination IP address
cannot be the local IP address and the peer IP address configured for the IPPATH.
The parameter cannot be modified.
The parameter cannot be modified.

The parameter cannot be modified.

None

This parameter can be modified only when the BTS is deactivated.

None

None

None

None

None.

None

None

None
The parameter cannot be modified.
The parameter cannot be modified.
The parameter cannot be modified.

None

None

None

None

None

None

None
The parameter cannot be modified.
None

This parameter takes effect only when the SDCCH exists on the TRXs on different
frequency bands.

None

None

None

None

The setting of this parameter needs negotiation with the MSC of the opposite network
element.
If the MSC supports processing assignment failure messages containing the cause
value of direct retry, set this parameter to YES; otherwise, set this parameter to NO.

None

If the value of this parameter is YES, the intra-BSC handovers (including intra-cell
handovers) in which the cell is the source or destination cell are processed as
asynchronous handovers.

If this parameter is set to 15, this protection is disabled.

None

This parameter applies to only the double-transceiver BTS and the corresponding
distributed BTS.

This parameter applies to only the double-transceiver BTS and the corresponding
distributed BTS.

None

None

None

None

None

None

None

This parameter is related to the actual physical connection of the BC. This parameter is
modified only when the NSVC service is faulty.
If this parameter is set to a small value, the detection of service type is sensitive and
may lead to ping-pong handover between different services.
None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

Generally, the value of this parameter does not need adjustment. It is the lower limit
for adjusting the value of DLLongTermFERTarget.

This parameter is used for the adaptive adjustment function of AMR downlink
threshold. When the voice is in poor performance not being affected by the channel
quality: If the low rate mode is more used in the adaptation, you can increase the value
of this parameter; if the high rate mode is more used in the adaptation, you can
decrease the value of this parameter. The adjustment range is from 4 to 20 and the
adjustment step is 2.
The target FER with the discontinuous transmission (DTX) enabled is a little higher than
the one without the DTX enabled. It is recommended that you set the value of this
parameter to 14 when the DTX is enabled. Based on this value, you can make
adjustments in the above mentioned principle according to actual test results.

Generally, the value of this parameter does not need adjustment. It is the upper limit
for adjusting the value of DLLongTermFERTarget.

Generally, the value of this parameter is fixed to 2, with no need of adjustment. The
value of this parameter decides only the adjustment value or the adjusting frequency
of the threshold. That is, the greater the value of this parameter is, the more frequently
the threshold is adjusted. The setting of this parameter, however, does not affect the
up or down adjustment of the threshold.

None

None

None

None

None

None

None

None

None

None

The setting of this parameter affects the triggering of a handover for poor quality in an
AMR full rate call. The smaller the value of this parameter is, the easier a downlink
handover due to a poor quality occurs.

The setting of this parameter affects the triggering of a handover for poor quality in an
AMR half rate call. The smaller the value of this parameter is, the easier a downlink
handover due to a poor quality occurs.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The downlink power control (at the BTS side) can support up to 15 levels, in each of
which the power of 2 dB is dynamically controlled.

During upgrade, pay more attention to the setting of this parameter. Be sure to check
it. If an area is allowed for receiving short messages, set this parameter to NO.
If the value of this parameter is YES, the MS in either idle or connected mode cannot
occupy radio channel resources to send short messages.

None

None

None

None

None

None

None

None

If you do not use a dual-antenna to receive signals, set this parameter to 0.

None
The parameter cannot be modified.
1. The block of A interface must be configured.
2. If A over IP is configured, the configuration does not support the operation.
None

None

The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

This parameter can be added and modified. It cannot be deleted.

None

None

None

None

None

None

None
The parameter cannot be modified.

The priority of the signaling link should be the highest.

The parameter cannot be modified.


The existing networking can be affected when the relation between the VLAN and the
DSCP are reset.

None

None

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.

None

The parameter cannot be modified.


None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

This parameter can be modified only when the BTS is deactivated.

This parameter can be modified only when the BTS is deactivated.

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

It is used for interworking with products of other manufacturers.

None

None

The address must exist and respond to the PING request.

None

None

It is recommended that this parameter be set to Yes on a multiband cell.

None

None

None

None

None

1. If you set the start date or end date of daylight saving time (DST) to a day of the
week after a specific date, the specific date must be six days or more days prior to the
last day of the month. For example, the last day of October is the 31st day. Then, the
specific date cannot be later than the 25th (31 6) day. If you set the specific date to
Tuesday after 26 October, this date is not included in the November of 2005. Therefore,
the specific date is invalid. This date in 2006, however, is October 31, which is valid. As
a result, you must follow this principle to ensure that a specific data is always valid.
2. You are not allowed to set the start date or end date of DST to February 29. This is
because that the local time changes between the start date and end date of DST. In a
non-leap year, February 29 does not exist. Therefore, the local time cannot change
between DST and non-DST.
3. The start month and end month of DST cannot be the same.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

For the modification of the parameter, See the ITU-T Q704.

None

The parameter cannot be modified.

None

None

None

The parameter cannot be modified.

None

The parameter cannot be modified.

None

None
This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.
None

The value of this parameter must be the same at both the BSS side and the NSS side.
Whether the BSC6900 is encrypted and the chosen encryption algorithm type must be
described in the MAP function process of the MSC. When setting the encryption
algorithm type of the BSC6900, you must refer to the data configuration function of the
BSC6900 and the functions of the MS.

None

None

None

None
1. The block of A interface must be configured.
2. If A over IP is configured, the configuration does not support the operation.
3. The difference between the end CIC and the start CIC is smaller than 256.
None

None

None

None

None

None

1. The block of A interface must be configured.


2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.
1. The block of Ater interface must be configured.
2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.
None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None.

None

None

None

None

None

None

None

None

None

None

None

If the value of this parameter is too small, extension measurement reports are sent
frequently. If the value is too large, feedback information may not be sent promptly in
fewer extension measurement reports.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.


Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
The parameter cannot be modified.
Negotiation can succeed only when the configuration is consistent on the local and
peer ends.

None

None

The parameter cannot be modified.

None

This parameter can be modified only when the BTS is deactivated.

None

Negotiation fails if this parameter is modified.

Negotiation fails if this parameter is modified.

None

None

None

None

None

None

None

The value ranges of frequency numbers vary with corresponding band reporting.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

You must deactivate the cell before modifying this parameter and activate the cell after
modifying this parameter.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
If this parameter is set to a small value, error is likely to occur during the detection of
the burst packets.
None

The parameter cannot be modified.

None
Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

The default value of "MS_TXPWR_MAX_CCH" in the GSM900 and GSM850 cells is 5; the
default value of "MS_TXPWR_MAX_CCH" in the DCS1800 and PCS1900 cells is 0.

None

None

In "EXP ELABEL", the "FN" parameter cannot be a space or any of the following
characters: '@', '#', '!', '%', '^', '&', '*', '[', ']', '\'', '\\'.
None

None

None

None

None

None

None

None

None

When this parameter is set to YES, during the channel activation of the BSC6900, if the
allocated channel speech version is full rate speech version 1 whereas the MS supports
full rate speech version 2, the BSC6900 changes the speech version to full rate speech
version 2 and sends it to the BTS. For the MSC, however, this change is shielded. The
speech version viewed at the MSC side is still full rate speech version 1.

None

None

This parameter can be modified only when the BTS is deactivated.

The adjacent node ID must be configured.

None

None

None
No_HC: disable the header compression function; RTP/UDP/IP_HC: enable the
RTP/UDP/IP/PPP function

For a BTS of the BTS3X series, the value of this parameter is invalid.

None

None

The value range of this parameter depends on the frequency range of the cell band.

None

None

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

If the BCCH frequency of a cell is changed, the BSC6900 forcibly hands over the calls in
this cell to another cell and then resets this cell.

None

None

None

None

None

None

None

This parameter is valid in only the cells in the coverage area of the BTS3X.

None

None

None

This parameter can be modified only when the BTS is deactivated.

None

This parameter can be modified only when the BTS is deactivated.

None

The FACTORTABLE must be configured.


The parameter cannot be modified.
The parameter cannot be modified.

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.


The parameter cannot be modified.
The parameter cannot be modified.
None

None

None

None

None

None

None

None

None

None

None

None

None

This parameter determines whether to load data from the OMU or the FLASH when the
BSC6900 or the board is restarted. The equipment is affected.

The value of this parameter is valid only for the BTSs of the double-transceiver series
and the distributed BTSs.

None

None

None

None

None

None

None

None

None

None

None

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.

None

None

None

The parameter cannot be modified.


The parameter cannot be modified.

None

The parameter cannot be modified.


None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

This parameter is supported only by the BTS3002C.

This parameter is supported only by the BTS3002C.

If the TRXs in a cell under this BSC6900 are at a frequency on DCS1800, this parameter
cannot be set to PCS1900, and vice versa.

None

None

When this parameter is set to No, Highest Priority cannot be configured.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The value of this parameter cannot be changed.

None
The value of this parameter must be the same as the attribute value of the TRX
frequency hopping of this frequency hopping group.

None

None

None

None

The parameter cannot be modified.

After this parameter is modified, the services in the cell are handed over forcedly. The
cell is reset after all the handover succeeds or after ten seconds.

None

None

None

None

None

None

None

Before the modification, the cell mapping table bound to the signaling point must be
deleted.

None

Set this parameter properly to ensure that hierarchical handover and load-based
handover can function properly. During hierarchical handover and load-based
handover, the downlink received level of the target cell must be greater than this
threshold.

None

None

None

None

None

None

None

None

None

None

None

HSNs are optional for the cells with frequency hopping enabled. The cells in the same
frequency group must use different HSNs. The HSNs of all the channels in a cell must
be the same.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

This parameter is supported only by the BTS3012A and BTS3006A.

For details of the timer, see ITU-T Q.714. The modification is not recommended.

None

None

None

For details of the timer, see ITU-T Q.714. The modification is not recommended.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter IBCA Allowed of the serving cell and the neighbor cell should be set to
Yes before the configuration of this parameter.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

When the network status is poor, the packet length should not be too large. Otherwise,
the path state is affected.

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

The parameter cannot be modified.

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

This parameter can be modified only when the BTS is deactivated.

None

None

None

None

None

None

None

This parameter must be equal to or less than "OUTHOPWROVERLOADTHRESHOLD" to


protect the other timeslots/cells from overload and underpower.

None

None

None

None

None

None

None

None

None

None

None

None

This parameter can be modified only when the BTS is deactivated.


The parameter cannot be modified.
None

None

None

This parameter can be modified only when the BTS is deactivated.


The parameter cannot be modified.
This parameter can be modified only when the BTS is deactivated.
The parameter cannot be modified.
None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

1. Interference band 0 is not counted in the traffic statistics.


2. In the following BTSs, the value range of this parameter is 115 to 85: BTS2X of all
the versions, BTS3X 03.1130 of the earlier versions, 3001C07.0301 of the earlier
versions, and 3002C02.0820 of the earlier versions. If this parameter is set to a value
beyond the range, the concerned cells cannot work.
3. In the following BTSs, the value range is 115 to 48: BTS3X 03.1130 and its later
versions, 3001c 07.0301 and its later versions, 3002c 02.0820 and its later versions,
and double-transceiver BTSs.
4. If the value of this parameter is too great, the averaging result cannot accurately
reflect changes. If the value is too small, frequent averaging of interference levels
causes a waste of resources.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.

None

None

None

The parameter cannot be modified.

None

The parameter cannot be modified.

The parameter cannot be modified.


The parameter cannot be modified.

The parameter cannot be modified.


The parameter cannot be modified.
None

None

None

None

None

None

None

None

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.

No_HC: disable the header compression function; RTP/UDP/IP_HC: enable the


RTP/UDP/IP/PPP function
The parameter cannot be modified.
The parameter cannot be modified.
None
This parameter depends on the type of the actual physical IP transport cable of the
BTS.
This parameter must be set according to the medium type of the actual IP transmission
cable used by the BTS.

None

None

None

None

None

None

None

None
The parameter cannot be modified.
None

Each cell can be configured with only one TRX that carries the main BCCH.

None

None

None

The parameter cannot be modified.

The parameter IPPATH must be configured in advance.

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

The setting of this parameter must be consistent with that on the peer.

The setting of this parameter must be consistent with that on the peer.

The setting of this parameter must be consistent with that on the peer.

None

None

The setting of this parameter must be consistent with that on the peer.

The setting of this parameter must be consistent with that on the peer.

The setting of this parameter must be consistent with that on the peer.

It is used for interworking with products of other manufacturers.

None
1. This command is applicable to the boards AOUa, POUa, AOUc, POUc, and OIUa.
2. It is used for interworking with products of other manufacturers.

None
1. This command is applicable to the boards AOUa and POUa.
2. It is used for interworking with products of other manufacturers.

The setting of this parameter must be negotiated with that on the interconnected side.

None

None

None

The setting of this parameter must be negotiated with that on the interconnected side.

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None
The parameter cannot be modified.
The parameter cannot be modified.

None

None

None

None

None

None

None

None.

None

None

None

None

None

The parameter cannot be modified.


The parameter cannot be modified.
None

None

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.

This parameter must be less than "UHUMTHD".

None

None
The parameter cannot be modified.

None

The parameter cannot be modified.


None

None

None

None

None

The setting of this parameter must be consistent with that on the peer.
The parameter cannot be modified.

The parameter cannot be modified.

According to the MTP3 load sharing principle, the link selection mask must be set
properly. If the value is not set properly, the load sharing between MTP3 links may fail.

The mask is calculated according to the link set to a destination entity.

None

None

This parameter is valid only when "NC2LoadResel" is set to SUPPORT.

None

None.

None

None

None

None.

None

None

None

None

The reciprocal of the parameter value is the ratio of the MSs to perform a load
handover.

None

None

The function of cell load reselection is valid only when "NC2LoadResel" in "SET
BSCPSSOFTPARA" is set to Support and "LOADRESELALLOW"is set to Permit.

None

None

None

None

None.

None

None

None

None

The parameter cannot be modified.


The local IP address and peer IP must be configured in the same network segment. The
peer IP address cannot be the same with the local IP address of the BSC6900.
The parameter cannot be modified.
None

The parameter cannot be modified.

None

None

The both end address of the SCTP is the parameter for the interconnection. The value
can be modified after the negotiation with the peer system.

The both end address of the SCTP is the parameter for the interconnection. The value
can be modified after the negotiation with the peer system.

None

The parameter can be modified when "MODE" in the command "ADD SCTPLNK" is set
to Client.

None

None

None

None

None

It is valid when "LOGPORTFLAG[/PARA in the command "ADD SCTPLNK" is ON.

It is valid when "LOGPORTFLAG[/PARA in the command "ADD SCTPLNK" is ON.

None

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.
The parameter cannot be modified.
None

None

1. When the peer end unconditionally changes the bits in the check message, the
services are disrupted if the switch is set to ON.
2. When the switch is set to OFF, the alarm "Inconsistent Configurations at the Two
Ends of the Link over the Ater Interface" will not be reported.

The parameter cannot be modified.


None

None

None

If this parameter is set to REMOTE_LOOP and LOCAL_LOOP, the service on this link is
affected until the loopback is cancelled.
When the upper layer bearer is IMAGRP, IMAGRP is reset after the loopback is canceled.
Otherwise, the state of the IMAGRP is abnormal and upper layer service cannot be
established.
When the loopback type is changed to REMOTE_LOOP or LOCAL_LOOP, the service is
affected. The service becomes normal when the loopback test is canceled. When the
loopback type is set to LOCAL_LOOP, you cannot directly change it to REMOTE_LOOP.
You must change it to NO_LOOP first and then to REMOTE_LOOP. You can change the
loopback type from REMOTE_LOOP to LOCAL_LOOP in the similar way.

None

None

None

None
For the BTS3002C, if each cell is configured with two TRXs (O2 or S2) and the value of
this parameter is YES, the radio frequency (RF) connection supports the configuration
of the main diversity antennas. Only the BTS3002C has this parameter.

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

This parameter must be less than "UTEMTHD".

Generally, the value of this parameter does not need adjustment. It is the lower limit
for adjusting the value of LongTermFERTarget.

The value of this parameter decides whether the threshold is adjusted upwards or
downwards. When the voice is in poor performance (excluding the cause of poor
channel quality: If the low rate mode is more used in the adaptation, you can increase
the value of this parameter; if the high rate mode is more used in the adaptation
(excluding the cause of good channel quality), you can decrease the value of this
parameter. If the DTX function is enabled, the value of this parameter must be a little
greater than the value when the DTX function is disabled.

Generally, the value of this parameter does not need adjustment. It is the upper limit
for adjusting the value of LongTermFERTarget.

Generally, the value of this parameter is fixed to 2, with no need of adjustment. The
value of this parameter decides only the adjustment value or the adjusting frequency
of the threshold. That is, the greater the value of this parameter is, the more frequently
the threshold is adjusted. The setting of this parameter, however, does not affect the
up or down adjustment of the threshold.

The adjustment of the parameter setting changes the service distribution on the DSPs.
The DSPs without LVDS links do not carry services.

None

None

None

The parameter modification should be negotiated with the peer end, and the BSC6900
should be reset after the modification. It is recommended that this parameter should
not be modified when the system is running.
None

None

None

If there are fewer frequencies in a frequency hopping group, the mode of Frequency
List can decrease the length of an assignment or handover command to facilitate the
access of an MS.

The parameter cannot be modified.

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

None
The parameter cannot be modified.
The parameter cannot be modified.
The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

None

The modification of the parameter affects the sensitivity of the SCTP link detection. The
larger the value is, the longer the link detection time is.
None

None

None

None

None

None

None

The adjacent node ID must be configured.

1. In the earlier versions of BSC6000V900R008C01B060SP06 and


BSC6000V900R0086C01B060SP06, a maximum of 50 BTSs can be downloaded
simultaneously on one BSC through the M2000 client. In
BSC6000V900R008C01B060SP06 and BSC6000V900R0086C01B060SP06 and its later
versions, a maximum of 100 BTSs can be downloaded simultaneously on one BSC
through the M2000 client. Therefore, the number of BTSs to be downloaded should
take the intersection of the value of this parameter and the number of BTSs supported
by the M2000 client.
2. If the BTS software versions downloaded simultaneously are excessive, the CPU
usage of the OMU increases. In this case, the services are likely to be affected.

The value of this parameter cannot be smaller than the maximum PPPMUX sub-frame
length. The number sub-frame must be larger than 2 to enable the PPPMUX.

None

None

None

None
The modification of the parameter affects the sensitivity of the SCTP link detection. The
larger the value is, the longer the link detection time is.

None

None

None

None

None

None

None

You can increase this value when the handovers are slow or the handover success ratio
is low due to bad clock or transmission quality. For the handovers of an MS to succeed,
the following condition must be met: "Physical information MAX Retrans" x "Radio link
invalid count" > Interval between the EST IND message and the HO DETECT message
(120 to 180 ms); otherwise the handovers will fail for sure.

None

None

None

None

None

If the PPP frame length is larger than this value, PPPMUX multiplexing cannot be
performed. The value of this parameter cannot be larger than the maximum
multiplexing frame length wMuxMfl and the number sub-frame must be larger than 2
as the enabling condition of PPPMUX (the relation between the maximum sub-frame
length and the maximum multiplexing frame length is: MuxMaxSfL<=(wMuxMfl-8)/2 ).

None

None

None

If this parameter is set to a smaller value, the handover success rate may be affected.

None

None

None

Before performing single-point positioning, you need to remove GPS configuration


history records.
None
The parameter cannot be modified.

None

None
The parameter cannot be modified.
The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

This parameter is valid only when the MCPA algorithm is enabled.

None
The parameter cannot be modified.
The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

None

None

The Enhanced Measurement Report supports the measurement of 3G neighboring cells


to implement the interoperability between the 2G system and 3G system, and thus
ensures the service continuity.

The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.


None

To modify this parameter, run "STP GATEWAYCHK" first and then "STR GATEWAYCHK".

None

The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

None
The local end of the SCTP link is the server and the application type is NBAP, the
working mode should not be modified as the client.
For the SCTP link of the M3UA application, the working mode can be modified only
when the upper layer application is deleted.

The parameter cannot be modified.

None

None

None

None

The setting of this parameter must be negotiated with that on the interconnected side.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

Because the measurement reports may not always be correctly decoded when the
quality of a serving cell is poor, handovers may fail when the number of the lost
measurement reports exceeds the value set by this parameter. You can set a relatively
larger value for this parameter, thus enabling emergency handovers.

None

When this parameter is set to Noreport, the BTSs do not submit measurement reports
to the BSC, which disables handovers and power control, and greatly impacts on the
speech quality.
None

None

None

None

None

None

None

None

None

None

None

If the MSC pool function is enabled, and the value of this parameter is not NORMAL, the
DPC is not selected for call access.
If the GSM BSC is connected to the GSM MSC, it is recommended that you set this
parameter to R98_or_below. If the GSM BSC is connected to the UMTS MSC, it is
recommended that you set this parameter to R99_or_above.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.
The parameter cannot be modified.
None

None

None

The interconnection may be affected if this parameter is modified.

This parameter is supported only by the BTS3012A and BTS3006A.

None

None.

None.

None.

If the value of this parameter is increased, the cell congestion rate increases. If the
value of this parameter is decreased, one-way audio may persist after the handover.

If this parameter is set to YES, the call drop rate may increase.

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
The adjacent node ID must be configured.

None
The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

This parameter is valid only when "NC2SPT" in "SET GCELLGPRS" is set to YES and
"NCO" in "SET GCELLPSBASE" is set to NC2.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.
The parameter cannot be modified.
The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

This parameter is supported only by the following dual-density BTSs: BTS3012,


BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
The parameter cannot be modified.

None

None

None

None

None

The parameter cannot be modified.

None

None

None
The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

If this parameter is set to a larger value, the bandwidth of the service is smaller.

Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
None
The parameter cannot be modified.
The transmission priority of the service is affected if the queue DSCP value of the port
is modified.

The transmission priority of the service is affected if the queue DSCP value of the port
is modified.
None

None
The parameter cannot be modified.
None

None

None

None

None

None

None

None

If the parameter value is set relatively small, the sensitivity for detecting the OML
when it is broken is improved. When the parameter value is set too small and if the link
is intermittently disconnected, misjudgements may occur to the testing results.
If the parameter value is set relatively large, the sensitivity for detecting the OML when
it is broken is reduced. The testing results are reliable, though.

The parameter cannot be modified.

None

None

The parameter cannot be modified.

None

The parameter cannot be modified.

None

None

None

None

Before modifying this parameter, you must deactivate the cells bound to the OPC.

None
The parameter cannot be modified.
The parameter cannot be modified.

Primary operator index must be 0.

None
1. The block of A interface must be configured.
2. If A over IP is configured, the configuration does not support the operation.
1. The block of A interface must be configured.
2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.
1. The block of Ater interface must be configured.
2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.
None
The parameter cannot be modified.

None

None

None

None

None

The setting of this parameter must be consistent with that on the peer.

None

None

None

None

None

None

None

None

None

If this parameter is set to a greater value, too many channel resources are occupied
and the congestion occurs.
If this parameter is set to a smaller value, the handover success rate may fall.
If this parameter is set to a greater value, too many channel resources are occupied
and the congestion occurs.
If this parameter is set to a smaller value, the handover success rate may fall.
None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.


None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.


The parameter cannot be modified.
The parameter cannot be modified.
None

None

None

None
The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

If this parameter is set to a greater value, the CPU may be overloaded.


If this parameter is set to a smaller value, the call loss rate is high.
If this parameter is set to a greater value, the CPU may be overloaded.
If this parameter is set to a smaller value, the call loss rate is high.
If this parameter is set to a greater value, the CPU may be overloaded.
If this parameter is set to a smaller value, the call loss rate is high.

If this parameter is set to a greater value, the CPU may be overloaded.


If this parameter is set to a smaller value, the call loss rate is high.

None

None

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.

The parameter cannot be modified.


None
The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.


The local IP address and peer IP must be configured in the same network segment. The
peer IP address cannot be the same with the local IP address of the BSC6900.
The parameter cannot be modified.

The both end address of the SCTP is the parameter for the interconnection. The value
can be modified after the negotiation with the peer system.

The both end address of the SCTP is the parameter for the interconnection. The value
can be modified after the negotiation with the peer system.

The parameter cannot be modified.

The parameter cannot be modified.

The SCTP port number is the parameter for the negotiation. The value can be modified
after the negotiation with the peer system.

None

None

None

None

None

None

When the network status is poor, the check period should not be too small. Otherwise,
the path state is affected.

None

Negotiation fails if this parameter is modified.

Negotiation fails if this parameter is modified.

The SIGBVC must be reset after this switch is turned on. The BSC supports the PFC
when the SGSN supports the PFC.

None

If this parameter is set to a greater value, more paging messages are processed. When
the BSC6900 is overloaded, the control on the arrival rate of paging messages does not
take effect.
If this parameter is set to a smaller value, some paging messages that can be
processed by the BSC6900 are discarded, thus affecting the call success rate.
If the value of Pg State Period(ms) is changed, you need to change the value of this
parameter accordingly.
If this parameter is set to a higher value, more PS paging messages can be processed,
thus increasing the BSC load. As a result, the control on the message arrival rate may
fail to protect the BSC. If this parameter is set to a lower value, more PS paging
messages are discarded, thus affecting the paging success rate. It is recommended
that this parameter be set according to the actual PS paging volume and the CPU
usage of the BSC.
The setting of this parameter is closely related to that of "Paging Statistical Period".
When the value of "Paging Statistical Period" is changed, the value of this parameter
must be adjusted accordingly.
If this parameter is set to a smaller value, the control of the arrival rate of paging
messages is sensitive.
If this parameter is set to a greater value, the control is insensitive.
The adjacent node ID must be configured.

The parameter cannot be modified.

None

None

None

None

None

None

None

None
The parameter cannot be modified.

None

This parameter is valid for the EDGE TRX only.

None

None

This parameter is valid for the EDGE TRX only.

None

This parameter is valid only for EDGE TRXs and is invalid for ordinary TRXs.

None

None

None

If "Play switch" is set, the normal calls may be affected.

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.
The parameter cannot be modified.

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

1. The block of Ater interface must be configured.


2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.
The parameter cannot be modified.

None

None

None

When the loopback type is changed to REMOTE_LOOP or LOCAL_LOOP, the service is


affected. The service becomes normal when the loopback test is canceled. When the
loopback type is set to LOCAL_LOOP, you cannot directly change it to REMOTE_LOOP.
You must change it to NO_LOOP first and then to REMOTE_LOOP. You can change the
loopback type from REMOTE_LOOP to LOCAL_LOOP in the similar way.
The parameter cannot be modified.
1. This command is applicable to the boards AOUa and POUa.
2. It is used for interworking with products of other manufacturers.

The parameter cannot be modified.

The parameter cannot be modified.


The parameter cannot be modified.
The parameter cannot be modified.

The parameter cannot be modified.


None

None

None

None

This parameter can be modified only when the BTS is deactivated.

None

None

None

None

None

None

None

None

If this parameter is set to a greater value, the error is small.

None

None

None
The parameter cannot be modified.

The parameter cannot be modified.

None

None

This parameter can be added and modified. It cannot be deleted.

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.


None

None

ENABLE: the multiplexing frame function of the PPP link is enabled. DISABLE: the
multiplexing frame function of the PPP link is disabled.

This parameter can be added or modified but cannot be removed.

None

None

None
When the sampling rate of pre-processed measurement reports is set to 1, the
frequency of submitting pre-processed measurement reports should be set to one
report per two seconds or one report per four seconds.
None

None

None

None

None

None

None

None

None

Each layer has 16 priorities, numbered 1-16 respectively. If the number of the priority is
small, the priority is high. This parameter along with Layer of the Cell determines the
priority of a cell. The priority affects the sequence of neighboring cells for handover. It
also affects handover algorithms, such as PBGT handover algorithm and inter-layer
handover algorithm. For example, PBGT handovers can be performed only between the
cells at the same layer and hierarchy. If a 1800 MHz cell and a 900 MHz cell are at
different layers, a PBGT handover cannot be performed from the 1800 MHz cell to the
900 MHz cell. Consequently, handovers are performed slowly even if the speech quality
is good.

None

None

None
The routing priority is modified. In the case of multiple routes to the same signaling
point, the route priority is affected.
None

The parameter cannot be modified.

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

The parameter cannot be modified.


The parameter cannot be modified.

1. This command is applicable to the boards AOUa and POUa.


2. It is used for interworking with products of other manufacturers.
None

None

None

None

None
The modification of the parameter affects the adjacent node that is configured with the
factor table. After the successful modification, the parameter takes effect in the
following two cases:
1. New access subscriber.
2. Bandwidth modification of the existing subscriber
The modification of the parameter affects the adjacent node that is configured with the
factor table. After the successful modification, the parameter takes effect in the
following two cases:
1. New access subscriber.
2. Bandwidth modification of the existing subscriber
The SIGBVC must be reset after this switch is turned on. The BSC supports the PS HO
when the SGSN supports the PS HO.
The modification of the parameter affects the adjacent node configured with the
TRMMAP. After the successful modification, it is valid in the case of the new access of a
subscriber and the bandwidth modification of an existing subscriber.

The modification of the parameter affects the adjacent node configured with the
TRMMAP. After the successful modification, it is valid in the case of the new access of a
subscriber and the bandwidth modification of an existing subscriber.

If this parameter is set to a larger value, more packets are discarded when the
congestion occurs. Thus, the priority value of the major service should be smaller than
that of the minor service.

None

None
The modification of the parameter affects the adjacent node configured with the
TRMMAP. After the successful modification, it is valid in the case of the new access of a
subscriber and the bandwidth modification of an existing subscriber.
The modification of the parameter affects the adjacent node configured with the
TRMMAP. After the successful modification, it is valid in the case of the new access of a
subscriber and the bandwidth modification of an existing subscriber.

If this parameter is set to a larger value, more packets are discarded when the
congestion occurs. Thus, the priority value of the major service should be smaller than
that of the minor service.

None

None

This parameter should be set on the basis of the actual receiver sensitivity of the BTS
and the minimum access level of the MS to avoid the situation where a call cannot be
made even though there are signals detected.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.

None
The line code must be consistent with that on the interconnected side. HDB3 (HDB3
code) and AMI (AMI code) are used for E1 ports. B8ZS (B8ZS code) and AMI_ZCS (AMI
code) are used for T1 ports.

The frame structure must be consistent with that on the interconnected side.

The frame structure must be consistent with that on the interconnected side.

The frame structure must be consistent with that on the interconnected side.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
The transmission priority of the service is affected if the queue DSCP value of the port
is modified.
The transmission priority of the service is affected if the queue DSCP value of the port
is modified.
The transmission priority of the service is affected if the queue DSCP value of the port
is modified.
The transmission priority of the service is affected if the queue DSCP value of the port
is modified.
The transmission priority of the service is affected if the queue DSCP value of the port
is modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

None

None

None

This parameter is supported only by the BTS3012A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

None

None

None

None

None

None

This parameter should be set on the basis of the actual receiver sensitivity of the BTS
and the minimum access level of the MS to avoid the situation where a call cannot be
made even though there are signals detected.

For the BTS3X series and double-transceiver BTSs, this parameter does not affect MS
access but affects the reporting of CCCH_LOAD_IND. If the level received by the BCCH
on the network side is greater than the RACH Busy Threshold, the CCCH_LOAD_IND is
counted once whether the decoding is successful. The RACH whose level is lower than
the RACH Busy Threshold and whose decoding is successful is also counted. The
measurement period is the Average RACH Load Timeslot Number.
If the value of this parameter is too low, the BTS easily considers that the RACH
timeslot is busy and reports overload messages to the BSC6900. If the value is too
high, the BTS cannot determine the status of the RACH timeslot correctly.
The settings of the BTS312, BTS3001C, BTS3001CP, BTS3002C, and double-transceiver
BTS must be consistent with the meaning and requirement of the BTS30.

None

None

None

None

None

None

None
If this parameter is set to Algorithm I, the BTS performs AMR rate adaptation according
to the C/I value.
If this parameter is set to Algorithm II, the BTS performs AMR rate adaptation according
to the BER value. Algorithm II is valid only for the EMR.
If this parameter is set to None, the AMR rate adaptation algorithm is not enabled, and
a fixed coding rate is used.

None

None

None

None

None

None

None

None

None

None

To improve the success rate of reassignment, it is recommended that you use the
default value Different Band. That is, the frequency band of the preferentially
reassigned channel is different from what is used in the original assignment.
None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

The parameter must be set to a value smaller than the number of TCHs available on
the BCCH TRX to prevent the frequent enabling and disabling of the power amplifier of
a TRX.

None

None

None

None

None

None

The parameter cannot be modified.

The setting of this parameter requires negotiation with the MSC, so that the MSC can
correctly process HO RQD messages.

None
Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
Negotiation can succeed only when the configuration is consistent on the local and
peer ends.
None

None

The range of this parameter is determined by the cell configuration. The lower limit is
0, and the upper limit is sum of TCHF, TCHH and Dynamic PDCH configured in the cell.

If this parameter is set to a greater value, the BTS power decreases too much. If this
parameter is set to a smaller value, the BTS power decreases insignificantly and thus
the power decrease effect is unsatisfactory.

None

None

None

None

The SIGBVC must be reset after this switch is turned on. The BSC supports the RIM
when the SGSN supports the RIM.

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

The resource group must exist.

The parameter cannot be modified.


The parameter cannot be modified.

None

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

None

The parameter cannot be modified.

None

None

None

None

None

The switch is off in the case of a signaling point to the single link. After the link to a
signaling point is disconnected, the restart procedure is performed. See the ITU-T
Q704.

None

None

Change this parameter will impact the function interrelated with Parameter 1.

Change this parameter will impact the function interrelated with Parameter 10.

Change this parameter will impact the function interrelated with Parameter 2.

Change this parameter will impact the function interrelated with Parameter 3.

Change this parameter will impact the function interrelated with Parameter 4.

Change this parameter will impact the function interrelated with Parameter 5.

Change this parameter will impact the function interrelated with Parameter 6.

Change this parameter will impact the function interrelated with Parameter 7.

Change this parameter will impact the function interrelated with Parameter 8.

Change this parameter will impact the function interrelated with Parameter 9.

None

The setting of this parameter must be negotiated with that on the interconnected side.

The routing context must be unique and needs to be negotiated with the peer.

None

None

None

None

None

None

None

The value should be greater than "RTOMIN" and smaller than "RTOMAX" in the
command "ADD SCTPLNK".

The value should be greater than "RTOMIN" in the command "ADD SCTPLNK".

The value should be smaller than "RTOMAX" in the command "ADD SCTPLNK".

None

None

None

None

None

None

None

None

None
For AMR calls, this parameter, together with "Interfere HO Qual Thresh n for Non-AMR
FR", is used in interference handover decision. An uplink interference handover is
easily triggered if this parameter is set to a smaller value.
If the value of this parameter is too small, the required level of received signals is low.
Therefore, many MSs attempt to camp on the cell, thus increasing the load of the cell
and the risk of call drops. In such a case, you must set the parameter based on the
balance conditions of the uplink and downlink levels.

None

This parameter is used in handover decision. An uplink interference handover is easily


triggered if this parameter is set to a smaller value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a smaller value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a smaller value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a smaller value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a smaller value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a too small value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a smaller value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a smaller value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a too small value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a smaller value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a too small value.
This parameter is used in handover decision. An uplink interference handover is easily
triggered if this parameter is set to a smaller value.
The parameter cannot be modified.

None

None

The parameter cannot be modified.

None

The parameter cannot be modified.

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

When the same coverage cell allows the load handover, this parameter should be set
to a value lower than "Load HO Threshold" of the same coverage cell.
None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

The setting of this parameter must be negotiated with that on the interconnected side.

None

1. If you set the start date or end date of DST to a day of the week after a specific date,
the specific date must be six days or more days prior to the last day of the month. For
example, the last day of October is the 31st day. Then, the specific date cannot be later
than the 25th (31 6) day. If you set the specific date to Tuesday after 26 October, this
date is not included in the November of 2005. Therefore, the specific date is invalid.
This date in 2006, however, is October 31, which is valid. As a result, you must follow
this principle to ensure that a specific data is always valid.
2. You are not allowed to set the start date or end date of DST to February 29. This is
because that the local time changes between DST and non-DST. In a non-leap year,
February 29 does not exist. Therefore, the local time cannot change between the start
date and the end date.
3. The start month and end month of DST cannot be the same.

None

If the parameter "IBCA Allowed" is set to YES, the BSC waits for MRs on the SDCCH for
the duration specified by the parameter "IBCA Assign Waiting Mr Time". This parameter
takes effect when the parameter "IBCA Allowed" is set to NO.

None

The level values 0 through 63 map to -110 dBm to -47 dBm. A smaller value indicates a
lower receive level.

The parameter value corresponds to RQ (quality level: 0 to 7) multiplied by 10. A


greater value indicates a poorer receive quality.

The level values 0 through 63 map to -110 dBm to -47 dBm. A smaller value indicates a
lower receive level.

The parameter value corresponds to RQ (quality level: 0 to 7) multiplied by 10. A


greater value indicates a poorer receive quality.

The SDCCH dynamic adjustment converts the TCHs to the SDCCHs, this reduces the
available TCHs and decreases the TCH traffic bearing capability.
The setting of this parameter must be negotiated with that on the interconnected side.

None

None

None

None

None

None

None
The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

This parameter should be set on the basis of the negotiation with the MSC at the peer
end.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None
The ratio of the subscribers accessing this SGSN is affected when this parameter is
modified.
The parameter cannot be modified.
None

None

None

None

If this SGSN is the last SGSN connecting this cell:


1. When the parameter is set to DENY, the services of all the online subscribers are
interrupted and new subscribers cannot access the network.
2. When the parameter is set to UNINSTALL, the services of all the online subscribers
are not interrupted and new subscribers cannot access the network.

None

The parameter cannot be modified.

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.


The parameter cannot be modified.
The ratio of Gb interface signaling messages sent through NSVLs is affected when this
parameter is modified. When this NSVL is the last NSVL of the normal state in the NSE,
if "SIGLW" is set to 0, the signaling exchange between the NSE and SGSN is
interrupted.

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
The source IP address can be: local IP address of the PPP link (PEUa/POUa/POS), local IP
address of the MP group ((PEUa/POUa), IP address of the Ethernet port of the local port
(FG2a/GOUa), and IP address of the local board.
The parameter cannot be modified.
None

None

None

The parameter cannot be modified.

None

The modified parameter takes effect after the BSC6900 is reset.

None

None

The value of this parameter cannot be changed.

None

None

None

None

The parameter cannot be modified.

None

None

None

The parameter cannot be modified.


None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

1. The block of Ater interface must be configured.


2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.

The parameter cannot be modified.

None

The parameter cannot be modified.


The parameter cannot be modified.

None

None

This parameter can be modified only when the BTS is deactivated.

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.


None

None

None

None

None

None
This parameter should be set on the basis of the negotiation with the MSC at the peer
end so that the MSC can process the assignment complete message properly. In the
assignment request, if the speech/data indicator in the channel type is data, the
assignment complete message does not carry SPEECH_VER regardless of the setting of
this parameter.
This parameter should be set on the basis of the negotiation with the MSC at the peer
end so that the MSC can process the Handover Perform message properly. For SDCCH
handovers, the Handover Perform message does not carry speech_ver even if this
parameter is set to Yes.
This parameter should be set on the basis of the negotiation with the MSC at the peer
end so that the MSC can process the HO REQ ACK message properly.
This parameter should be set on the basis of the negotiation with the MSC at the peer
end.
This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.
This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.

The port can be set to the DOWN or UP state when this parameter is modified. If the
speed modes on the local and peer end are not consistent, the service can be
interrupted.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

Clock sources and priorities are in one-to-one mapping.

Clock sources and priorities are in one-to-one mapping.

None

None
None

None
The parameter cannot be modified.
None
The parameter cannot be modified.

Clock sources and priorities are in one-to-one mapping. Each backplane board 8K clock
has only one clock source.

None

The parameter cannot be modified.

None

The parameter cannot be modified.

None

The parameter cannot be modified.

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.

1. The block of Ater interface must be configured.


2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.
None

The parameter cannot be modified.

The parameter cannot be modified.

None

None

This parameter can be modified only when the BTS is deactivated.

None
1. The command is used for the configuration when the TDM resources exist between
two subracks.
2. Each subrack must be the BM subrack or TC subrack.
1. The command is used for the configuration when the TDM resources exist between
two subracks.
2. Each subrack must be the BM subrack or TC subrack.
None

None
If the interface board clock source of the MPS/TCS subrack is set, you can set the 8 kHz
output clock source. For the MPS and TCS, you can set the backplane board 8K output
clock as the clock source of the interface board. For the EPS, you cannot perform the
setting.

None
The ratio of Gb interface signaling messages sent through local NSVLs is affected when
this parameter is modified. When this NSVL is the last NSVL of the normal state in the
NSE, if "SRVLW" is set to 0, all the packet services of the local NSE are interrupted.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
In principle, you should not configure the frequencies on the P frequency band and on
the E frequency band in one MA group.
If the frequencies on the P frequency band and on the E frequency band are configured
in one MA group, some MSs may not process calls.
In this case, you can set this parameter to No.
After that, if some other MSs cannot process calls, set this parameter to Yes and divide
the MA group.
None

1. The block of A interface must be configured.


2. If A over IP is configured, the configuration does not support the operation.

None

None

None

None

None

None

None
This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.
None
1. The block of A interface must be configured.
2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.
1. The block of Ater interface must be configured.
2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.
None

None

None

None

None

None

None

The parameter cannot be modified.


None

None

None
This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.
The parameter cannot be modified.
None

None

None

None

None

None

None

None

None

None

None

The adjacent node ID must be configured.

None

None

None

None

None

None

None

None

None

None

When the simple cell broadcast function is enabled, the BSC6900 provides the simple
cell broadcast service if the CBC is not provided. The simple cell broadcast function is
used to broadcast the messages that are not changed frequently.
The simple cell broadcast function and the cell broadcast function provided by the CBC
cannot be enabled simultaneously.

The high multislot class function requires the support from the MS. For an MS of a high
multislot class 32, 33, or34, the extended dynamic allocation (EDA) function must be
used if more than three timeslots are required on the uplink.

None

The EDA requires the support from the MS.

None

None

This parameter should be set according to the requirements of the existing network.
If this parameter is set to Yes, the voice signals are encoded only once at the
originating MS and decoded only once at the terminating MS. This improves the QoS of
the MS-to-MS call.
The TFO function is performed only between an MS and another MS, not between a
fixed-line phone and an MS. If the TFO function is enabled, a lot of GDPUC resources
are occupied.

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

Change this parameter will impact the patch function controlled by switch 1.

Change this parameter will impact the patch function controlled by switch 10.

Change this parameter will impact the patch function controlled by switch 2.

Change this parameter will impact the patch function controlled by switch 3.

Change this parameter will impact the patch function controlled by switch 4.

Change this parameter will impact the patch function controlled by switch 5.

Change this parameter will impact the patch function controlled by switch 6.

Change this parameter will impact the patch function controlled by switch 7.

Change this parameter will impact the patch function controlled by switch 8.

Change this parameter will impact the patch function controlled by switch 9.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The physical information is sent over the FACCH. Every four TDMA frames are sent once
over the FACCH, which takes 18 ms. If the T3105 timer is set to less than 18 ms, when
the T3105 timer expires for the first time, the physical information needs to be
retransmitted. But at this time, the previous physical information has not sent over the
FACCH (the FACCH period is not reached).

None

None

None

It is recommended that you select a greater value, such as 16, 20, or 25, in the area
with heavy traffic,
but a smaller value, such as 2 or 3, in the area with light traffic.
To properly specify the value of this parameter, it is necessary to perform overall and
long-term measurement on the entities involved regarding their processing capability
and traffic, such as the processing capability of the MSC and BSC, and the load on the
A interface, Abis interface, Um interface, HLR, and VLR.
The location update period in the MSC must be greater than that in the BSC.
In the GSM system, it is possible that a powered-on MS is identified as implicit off-line if
the MS sends no location update request within a long period.
When the MS reselects another cell (in the same LAC), the MS is restarted through
T3212 timeout if the T3212 of the new cell differs from that of the original cell.
When this parameter differs in the cells of the same LAC, it is possible that the MS is
identified as implicit off-line if the MS sends no location update request for a long
period. In this case, system plays "The subscriber you dial is power off." even though
the called MS is on.
In an LAC, the value of this parameter should be the same in all cells.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

According to the GSM protocols, the BSC6900 performs CRC on each TRAU frame. If the
CRC of a certain TRAU frame fails, the TRAU frame is regarded as an invalid one. Then,
the BSC6900 performs smoothing on the invalid frame, thus eliminating the noise
caused by the errors in parameter transmission. The CRC should be performed on the
TRAU frames of all speech services except the FR service.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

The parameter cannot be modified.

None

The parameter cannot be modified.

The parameter cannot be modified.

None

None

None

None

None

None

None

None

Before switched on, please insure that all the TRXs in this cell are suitable version.

None

None

None

None

None

None

The parameter cannot be modified.


The parameter cannot be modified.
1. The command is used for the configuration when the TDM resources exist between
two subracks.
2. Each subrack must be the BM subrack or TC subrack.
1. The command is used for the configuration when the TDM resources exist between
two subracks.
2. Each subrack must be the BM subrack or TC subrack.
None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None
For the BTS3001C, BTS3001CP, and BTS3002C, this parameter is invalid. For other
BTSs, this parameter is valid.
None

None
The IP address of the TGW cannot use the configured IP address of another TGW . The
IP address of TGW cannot be the same as the IP address configured in the BSC6900.
Otherwise, operation and maintenance channel for TGW fails.
The IP address of the TGW cannot use the configured IP address of another TGW. The IP
address of TGW cannot be the same as the IP address configured in the BSC6900.
Otherwise, operation and maintenance channel for TGW fails.
None
The IP address of the TGW cannot use the configured IP address of another TGW . The
IP address of TGW cannot be the same as the IP address configured in the BSC6900.
Otherwise, operation and maintenance channel for TGW fails.

None

This parameter is supported only by the BTS3012A and BTS3006A.

This parameter is supported only by the BTS3012A and BTS3006A.

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.
None

None

None

None

None

None

None

Multi-band networks cannot use the TIGHT BCCH algorithm.

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.


The parameter cannot be modified.
The parameter cannot be modified.
The parameter cannot be modified.

None

The parameter cannot be modified.

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None
The parameter cannot be modified.
The TRMMAP must be configured.

None

None

None

1. If you set "Upper time threshold of raised fault" and "Lower time threshold of raised
fault" to "0", the accumulated alarm blink duration is counted but not reported.
2. If "Upper time threshold of raised fault" is not "0", the value of "Lower time threshold
of raised fault" cannot be "0" and you must ensure that "Upper time threshold of raised
fault" is greater than "Lower time threshold of raised fault".
3. When "Upper time threshold of raised fault" is not "0" and "Alarm switch of blinking
filter" and "Switch of stat blinking alarm" are "ENABLE", you cannot set "Alarm blink
threshold" to "0". Otherwise, blink statistics of the alarm is not performed.

None

1. If you set "Upper time threshold of raised fault" and "Lower time threshold of raised
fault" to "0", the accumulated alarm blink duration is counted but not reported.
2. If "Upper time threshold of raised fault" is not "0", the value of "Lower time threshold
of raised fault" cannot be "0" and you must ensure that "Lower time threshold of raised
fault" is smaller than or equal to "Upper time threshold of raised fault".
3. When "Lower time threshold of raised fault" is not "0" and "Alarm switch of blinking
filter" and "Switch of stat blinking alarm" are "ENABLE", you cannot set "Alarm blink
threshold" to "0". Otherwise, blink statistics of the alarm is not performed.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

The parameter cannot be modified.


The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.

None

The parameter cannot be modified.

None

None

None

None

None

None

None
The parameter cannot be modified.
The parameter cannot be modified.

The parameter cannot be modified.

The parameter cannot be modified.


The parameter cannot be modified.
None

The TRM load threshold must be configured already.


The parameter cannot be modified.
The TRM load threshold must be configured already.

The TRM load threshold must be configured already.

None

None
The parameter cannot be modified.
The parameter cannot be modified.
The parameter cannot be modified.

This parameter specifies whether to enable the TRX aiding function.


BCCH aiding: The main BCCH is aided to another normal TRX in this cell.
BCCH aiding switchback: BCCH aiding switchback functions after the originally
configured BCCH TRX is recovered.
Baseband FH aiding: When the TRX involved in baseband FH in the cell is faulty or
BCCH aiding is performed in the cell, baseband FH aiding occurs and the cell is
initialized as a non-hopping cell.
Baseband FH aiding switchback: When all the TRXs involved in baseband hopping in
the cell are recovered and the originally configured BCCH TRX is normal, baseband FH
aiding switchback can be performed and the cell is restored to the baseband FH mode.
After TRX aiding (BCCH aiding or baseband FH aiding) or switchback occurs, the cell is
re-initialized.
For any types of BTS, no aiding is performed within 15 minutes after the cell is
initialized.

None

After this parameter is modified, the services in the cell are handed over forcedly. The
cell is reset after all the handover succeeds or after ten seconds.

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

After this parameter is modified, the services in the cell are handed over forcedly. The
cell is reset after all the handover succeeds or after ten seconds.
None

None

The parameter cannot be modified.

The parameter cannot be modified.

None

The parameter cannot be modified.


1. The block of A interface must be configured.
2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.
1. The block of Ater interface must be configured.
2. If the BSC is configured to the integrated BMTC or A over IP is configured, the
configuration does not support the operation.
3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not
allowed to perform the block operation from the primary BM subrack to the secondary
BM subrack.
None

Loopback test, which cause the service interruption on this link

None

The modification of the PPP link that is between the BTS and the BSC will affect the
services.
The modification of the PPP link that is between the BTS and the lower-level BTSs will
lead to intermittent services carried by the lower-level BTSs.

The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

If this parameter is set to a great value, the PS DSP load will be heavy.

None

None

None

None

None

None

None

None

The parameter cannot be modified.

The parameter cannot be modified.


The parameter cannot be modified.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None.

None.

None.

None.

None.

None.

None.

None.

None

None

None
The parameter cannot be modified.

None

None

The value of this parameter cannot be changed.

The modified parameter takes effect after the BSC is reset.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

If this parameter is set to 0, the emergency call may be affected.

None

None

None

None
When RAI alarms occur on the E1 link, services cannot be assigned again by default.
After the switch is enabled, services can be assigned, but single-pass may occur on the
ongoing services.
None

None

None

None

None

None

None

None

None

None

None

None

The adjacent node ID must be configured.

None

The parameter cannot be modified.

None

None

The setting of this parameter must be greater than "LHUMTHD".

None
The parameter cannot be modified.
None

None

None

None

None

None

None

None

None

If this parameter is set to a small value, the detection of service type is sensitive and
may lead to ping-pong switching between different services.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The setting of this parameter affects the triggering of BQ(Bad Quality) handover of
AMR FR calls. If it is set to a smaller value, the uplink BQ handover is easily triggered.

The setting of this parameter affects the triggering of BQ handover of AMR HR calls. If
it is set to a smaller value, the uplink BQ handover is easily triggered.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

None

None

None

None

None

None

This parameter can be modified only when the BTS is deactivated.

None

The parameter cannot be modified.

None

This parameter can be modified only when the BTS is deactivated.

None

None

None

None

None

None

None

None

None

None

None

This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C,
BTS3012AE, BTS3012 II, and BTS3002E.
None

In a GSM900 cell, the power control level of the MS ranges from 0 to 19. Generally, the
maximum transmit power supported by an MS is level 5 (mapping to 33 dBm). The
minimum transmit power supported by an MS is level 19 (mapping to 5 dBm). Other
transmit power levels are reserved for high-power MSs.
In a GSM1800 or GSM1900 cell, the power control level of the MS ranges from 0 to 31.
Generally, the maximum transmit power supported by an MS is level 0 (mapping to 30
dBm). The minimum transmit power supported by an MS is level 15 (mapping to 2
dBm). Other transmit power levels are reserved for high-power MSs.

The parameter cannot be modified.


The parameter cannot be modified.

None

None

None

Pay special attention to the setting of this parameter during an upgrade. If sending
short messages is allowed, this parameter must be set to No.
If this parameter is set to Yes, radio channels cannot be used to send short messages
regardless of whether an MS is busy or not.

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The setting of this parameter must be greater than "LTEMTHD".

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None

Incorrect setting of this parameter can lead to access failure to the target IP address.

None
The parameter cannot be modified.
The parameter cannot be modified.

Incorrect setting of this parameter can lead to access failure to the target IP address.

Incorrect setting of this parameter can lead to access failure to the target IP address.

None

The existing networking can be affected when the relation between the VLAN and the
DSCP are reset.
None

None

None

None

None

None

None

None

None

If this parameter is set to a smaller value, the error is smaller.

None

None

None

None

None

None

None

None

None

If the timer is set to a greater value, the time of reserving channel resources for an
emergency call is long. In this case, the channel usage for ordinary calls is affected.
If the timer is set to a smaller value, reserved channel resources may not be assigned
to an emergency call. In this case, the call fails.

None

None

None

None

None

None

None

The parameter cannot be modified.

None

None
The parameter cannot be modified.

None

None

None

None

None

None

None

None

The conversion from E1 to T1 or from T1 to E1 takes effect after the board is reset.

None

None

None

None

The parameter cannot be modified.

None

Validation of Modification

Impact on Radio Network Performance

The parameter modification has no


impact on the equipment.

The smaller the value of this parameter is, the more


MSs select a neighboring cell in directed retry.

The parameter modification has no


impact on the equipment.

The smaller the value of this parameter is, the more


MSs select a neighboring cell in directed retry.

The parameter modification has no


impact on the equipment.

The setting of this parameter affects the access


delay of parts of MSs.

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

When the access control function is enabled, some


MSs are caused to be inaccessible to the network
for some time.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The throughput is affected.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The ACS may affect the MOS.

The parameter modification has no


impact on the equipment.

The ACS may affect the MOS.

The parameter modification has no


impact on the equipment.

The ACS may affect the MOS.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The switching from an intra-cell handover


procedure to an assignment procedure shortens the
duration of the intra-cell handover.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be reestablished after the parameter


modification.

None

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be reestablished after the parameter


modification.

None

The radio link should be reestablished after the parameter


modification.

If this parameter is set to OPEN, the acoustic echo


can be cancelled to improve the speech quality.

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be


reestablished after the parameter
modification.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to higher value, channel


resources may be wasted; if this parameter is set to
lower value, the call drop rate may increase.

The parameter modification has no


impact on the equipment.

If this parameter is set to higher value, channel


resources may be wasted; if this parameter is set to
lower value, the call drop rate may increase.

Not involved

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

If this parameter is set to higher value, channel


resources may be wasted; if this parameter is set to
lower value, the call drop rate may increase.

The parameter modification has no


impact on the equipment.

If this parameter is set to higher value, channel


resources may be wasted; if this parameter is set to
lower value, the call drop rate may increase.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The radio link should be reestablished after the parameter


modification.

None

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be


reestablished after the parameter
modification.

If this parameter is set to OPEN, the voltage level


can be adjusted automatically to improve the
speech quality.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


dynamic power adjustment range for the BTS is
decreased. This may cause power waste and
increase network interference when the downlink
quality is good.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

When this parameter is set to YES and the value of


the downlink threshold is not reasonable, the
algorithm can be used to dynamically adjust the
AMR downlink rate to increase the downlink speech
MOS.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, downlink


power control may not be performed when the
voice quality is good, thus causing the power waste
and increasing the interference. If this parameter is
set to a greater value, downlink power control may
be performed when the voice quality is bad, thus
affecting the voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, uplink


power control may not be performed when the
voice quality is bad, thus affecting the voice quality.
If this parameter is set to a smaller value, uplink
power control may be performed when the voice
quality is good, thus causing the power waste and
increasing the interference.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, downlink


power control may not be performed when the
downlink level is high, thus causing the power
waste and increasing the interference. If this
parameter is set to a smaller value, downlink power
control may be performed when the downlink
power is low, in this way, call drops may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, uplink


power control may be performed when the
downlink level is high, thus causing the power
waste and increasing the interference. If this
parameter is set to a smaller value, power control
may not be performed when the downlink power is
low, in this way, call drops may occur.

The parameter modification has no


impact on the equipment.

If this switch is turned on, AMR FR calls can be


switched into AMR HR calls to relieve the network
congestion, but the voice quality is decreased; if
this switch is turned off, AMR FR calls cannot be
switched into AMR HR calls, that is, network
congestion cannot be relieved through the
handover from TCHF to TCHH.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover margin is increased in a short period and
many MSs are handed over from TCHF to TCHH,
thus affecting the voice quality.
If this parameter is set to a smaller value, the
handover margin is enlarged slowly and it takes a
long time to initiate a TCHF-TCHH handover. Thus,
network congestion cannot be relieved in time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, only MSs


in the center of the cell can meet the handover
condition. Thus, the network congestion cannot be
relieved in time.
If this parameter is set to a smaller value, MSs at
the edge of the cell can also meet the handover
condition, thus affecting the voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover margin is increased in a short period and
many MSs are handed over from TCHF to TCHH,
thus affecting the voice quality.
If this parameter is set to a smaller value, the
handover margin is enlarged slowly and it takes a
long time to initiate a TCHF-TCHH handover. Thus,
network congestion cannot be relieved in time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, MSs at


the edge of the cell can also meet the handover
condition, thus affecting the voice quality.
If this parameter is set to a smaller value, only MSs
in the center of the cell can meet the handover
condition. Thus, the network congestion cannot be
relieved in time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, MSs with


poor quality can also meet the handover condition,
thus affecting the voice quality.
If this parameter is set to a smaller value, little MSs
can meet the handover condition. Thus, the
network congestion cannot be relieved in time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the calls


cannot be handed over to TCHH in a short period
when the traffic volume is increased greatly. Thus,
the network congestion cannot be relieved in time.
If this parameter is set to a smaller value, calls are
handed over to TCHH unnecessarily, thus causing
MOS loss of the customer.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, only MSs


in the center of the cell use the TCHH, thus leading
to timeslot waste and the network congestion
cannot be relieved in time. If this parameter is set
to a smaller value, MSs at the edge of the cell and
with poor quality also cannot be handed over to the
TCHF, thus affecting the voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, MSs at


the edge of the cell and with poor quality also
cannot be handed over to the TCHF, thus affecting
the voice quality. If this parameter is set to a
smaller value, only MSs in the center of the cell use
the TCHH, thus leading to timeslot waste and the
network congestion cannot be relieved in time.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, handover


cannot be triggered even when the quality is poor,
thus affecting the voice quality; if this parameter is
set to a smaller value, handover is triggered even
when the quality is good, thus the network
congestion cannot be relieved in time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, calls are


handed over to TCHH unnecessarily, thus causing
MOS loss of the customer; if this parameter is set to
a greater value, TCHF-TCHH handover is performed
only when the traffic volume is high, and thus
network congestion may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, call drops


may occur due to delayed power control; if this
parameter is set to a greater value, power waste
may occur and network interference may be
increased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, fast


power control cannot be realized. If this parameter
is set to a greater value, the power control may be
performed excessively, thus leading to call drops.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, fast


power control cannot be realized. If this parameter
is set to a greater value, the power control may be
performed excessively, thus leading to call drops.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, fast


power control cannot be realized. If this parameter
is set to a greater value, the power control may be
performed excessively, thus leading to call drops.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, call drops


may occur due to delayed power control; if this
parameter is set to a greater value, power waste
may occur and network interference may be
increased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, power


control may not be performed in time. If this
parameter is set to a smaller value, power control
may be performed frequently, thus increasing the
signaling load.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


algorithm cannot realize fast power control. If this
parameter is set to a greater value, call drops may
occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, cell


congestion may not be relieved. If this parameter is
set to a smaller value, TCHFs may be assigned
unnecessarily, thus affecting the voice quality.

The parameter modification has no


impact on the equipment.

When this parameter is set to YES and the value of


the uplink threshold is not reasonable, the
algorithm can be used to dynamically adjust the
AMR uplink rate to increase the uplink speech MOS.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, downlink


power control may not be performed when the
voice quality is good, thus causing the power waste
and increasing the interference. If this parameter is
set to a greater value, downlink power control may
be performed when the voice quality is bad, thus
affecting the voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, uplink


power control may not be performed when the
voice quality is bad, thus affecting the voice quality.
If this parameter is set to a smaller value, uplink
power control may be performed when the voice
quality is good, thus causing the power waste and
increasing the interference.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, power


control may not be performed when the uplink level
is high, thus causing the power waste and
increasing the interference. If this parameter is set
to a smaller value, downlink power control may be
performed when the uplink power is low, in this
way, call drops may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, uplink


power control may be performed when the uplink
level is high, thus causing the power waste and
increasing the interference. If this parameter is set
to a smaller value, power control may not be
performed when the uplink power is low, in this
way, call drops may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The radio link should be reestablished after the parameter


modification.

None

The radio link should be reestablished after the parameter


modification.

If this parameter is set to OPEN, the noise can be


compensated automatically to improve the speech
quality.

The radio link should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be reestablished after the parameter


modification.

None

The radio link should be


reestablished after the parameter
modification.

None

The radio link should be


reestablished after the parameter
modification.

If this parameter is set to OPEN, the noise can be


depressed automatically to improve the speech
quality.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to YES, the voice quality is


enhanced and the handover times is reduced, but
the call access delay is prolonged. The call access
delay is affected by both the setting of "Maximum
Assigning Duration" and the duration for waiting
MRs on the SDCCH. The maximum delay is the
value of "Maximum Assigning Duration". Enabling
this function may cause SDCCH congestion.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a higher value, channel


resources may be wasted and congestion occurs; if
this parameter is set to a lower value, the
assignment success rate may decrease.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


overlaid subcell range in the algorithm is smaller
than the actual range, thus leading to the
unbalance between the traffic volume on the
overlaid subcell and that on the underlaid subcell.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, TCHFs


are preferentially selected even when congestion
occur on the Ater interface, thus decreasing the
system capacity.
If this parameter is set to a lower value, TCHHs are
selected when no congestion occur on the Ater
interface, thus decreasing the voice quality.

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The BSC should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BSC6900 should be reset to


None
validate the parameter modification.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time, thus the
voice quality is decreased and call drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a smaller value,
handovers cannot be performed in time. Thus the
voice quality is decreased and call drops may occur.

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a smaller value, the
handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The setting of this parameter may affect the MS


paging response and performance of the system. A
greater value may decrease the number of paging
blocks, paging capacity, and paging success rate.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


number of paging subchannels in a cell increases
and the number of MSs on each paging subchannel
decreases. This can prolong the average service life
of MS batteries but increase the delay of paging
messages and degrade the system performance.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

Not involved

Not involved

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to BTS_Preprocessing,


signaling on the Abis interface and BSC load are
decreased, thus enhancing the response speed and
the network performance.

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the range


of BTS dynamic power adjustment is decreased,
and thus network interference is difficult to be
reduced.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

Call reestablishment can decrease the call drop rate


but waste channel resources.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


status of RF resources is reported too frequently,
thus burdening the BSC6900. If this parameter is
set to a greater value, the status of RF resources
cannot be updated in time; therefore, the BSC6900
cannot handle the interference to the BTS, thus
causing unreasonable channel allocation.

The parameter modification has no


impact on the equipment.

If this parameter is set to smaller value, the


signaling flow over the Abis interface increases,
thus burdening the BSC6900. If this parameter is
set to a greater value, the BSC6900 cannot handle
the exceptions on the BTS in time, thus causing
network congestion.

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, dynamic


adjustment may not be triggered when there are
insufficient SDCCHs in the cell, this affects the
access success rate. If this parameter is set to a
greater value, traffic volume on the TCH is
decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This feature only applies to the areas covered by


both the GSM network and the UMTS network. The
UMTS network is preferentially used to perform the
data services, and the GSM network is
preferentially used to perform the speech services.
When a user is handed over to the GSM network
during a call, the user must return to the UMTS
network immediately after the call is complete.
Thus, a location update is avoided.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set too small, the congestion


control duration is too long, and thus the
transmission capability of signaling links cannot be
fully used. If the difference between the values of
"CSTARTTHD" and "CENDTHD" is small, the
signaling link is unstable and congestion control is
performed frequently. In this case, the paging
messages may be abandoned.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The setting of this parameter depends on the actual


physical location of the chain neighboring cell.
Otherwise, fast PBGT handover may fail.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The board should be reset to


None
validate the parameter modification.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter can be used to limit the user access


type to control the network load; however, some
users may be adversely affected. Therefore, it is
recommended that this parameter be disabled.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value,


handovers may be performed frequently; if this
parameter is set to a greater value, handovers may
not be performed in time and call drops may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value,


handovers may be performed frequently; if this
parameter is set to a greater value, handovers may
not be performed in time and call drops may occur.

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The MS cannot respond to the paging during the


location update, thus decreasing the call
completion rate in the system.
If this parameter is set to a smaller value, pingpong
location update may occur, thus increasing the
signaling load on the SDCCH.
If this parameter is set to a greater value, the MS
may not camp on an optimum cell for a long time
after entering a new location area.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If the value of this parameter is too high, the


congestion control is delayed, which leads to
deteriorated performance on the signaling link and
certain messages may be lost.
If the difference between the values of
"CSTARTTHD" and "CENDTHD" is small, the
signaling link is unstable and congestion control is
performed frequently. In this case, the paging
messages may be abandoned.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this timer is set to a greater value, channel


resources may be wasted, thus causing congestion.

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

If this timer is set to a greater value, channel


resources may be wasted, thus causing congestion.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this function is enabled, number of signaling


channel handovers is increased and the access
speed is decreased, but the congestion on the
BCCH-compatible SDCCH can be relieved and the
access success rate is enhanced.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, call drops


may occur due to delayed handover; if this
parameter is set to a greater value, unnecessary
handover may be performed, thus affecting the
voice quality.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


down power adjustment may not be performed
when the downlink quality is good, thus causing
power waste and increasing the interference. If this
parameter is set to a relatively small value, down
power adjustment may be performed when the
downlink quality is poor. In this case, call drops may
occur.

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


up power adjustment may be performed when the
downlink quality is good, thus causing power waste
and increasing the interference. If this parameter is
set to a relatively small value, up power adjustment
may not be performed when the downlink quality is
poor. In this case, call drops may occur.

The parameter modification has no


impact on the equipment.

The throughput of the GPRS service is affected.

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


down power adjustment may not be performed
when the downlink quality is good, thus causing
power waste and increasing the interference. If this
parameter is set to a relatively small value, down
power adjustment may be performed when the
downlink quality is poor. In this case, call drops may
occur.

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


up power adjustment may be performed when the
downlink quality is good, thus causing power waste
and increasing the interference. If this parameter is
set to a relatively small value, up power adjustment
may not be performed when the downlink quality is
poor. In this case, call drops may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a relatively small value,


the fast power control on the downlink cannot be
implemented. If this parameter is set to a relatively
great value, the power control may be performed
excessively on the downlink, thus leading to poor
quality, low level, and ping-pong power control.

The parameter modification has no


impact on the equipment.

If this parameter is set to a relatively small value,


call drops may occur due to delayed power control
in the downlink. If this parameter is set to a
relatively great value, the power control may be
performed excessively on the downlink, thus
leading to ping-pong power control.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, downlink


power control may not be performed when the
voice quality is good, thus causing the power waste
and increasing the interference. If this parameter is
set to a greater value, downlink power control may
be performed when the voice quality is bad, thus
affecting the voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, uplink


power control may not be performed when the
voice quality is bad, thus affecting the voice quality.
If this parameter is set to a smaller value, uplink
power control may be performed when the voice
quality is good, thus causing the power waste and
increasing the interference.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, handover


may not be performed when the downlink voice
quality is bad, thus leading to call drops. If this
parameter is set to a smaller value, unnecessary
handovers may be performed, thus decreasing the
user experience and network traffic load.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


handovers due to bad downlink quality may
increase, thus decreasing the handover success
rate. If this parameter is set to a greater value,
handovers due to bad downlink quality are less
possible to occur, thus increasing the call drop rate.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


handovers due to bad downlink quality may
increase, thus decreasing the handover success
rate. If this parameter is set to a greater value,
handovers due to bad downlink quality are less
possible to occur, thus increasing the call drop rate.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, decrease


power control may not be performed when the
downlink level is high, thus causing the power
waste and increasing the interference. If this
parameter is set to a smaller value, decrease power
control may be performed when the downlink
power is low, in this way, call drops may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, increase


power control may be performed when the
downlink level is high, thus causing the power
waste and increasing the interference. If this
parameter is set to a smaller value, increase power
control may not be performed when the downlink
power is low, in this way, call drops may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, decrease


power control may not be performed when the
downlink level is high, thus causing the power
waste and increasing the interference. If this
parameter is set to a smaller value, decrease power
control may be performed when the downlink
power is low, in this way, call drops may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, increase


power control may be performed when the
downlink level is high, thus causing the power
waste and increasing the interference. If this
parameter is set to a smaller value, increase power
control may not be performed when the downlink
power is low, in this way, call drops may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set improperly to a small value,


the downlink assignment procedure may fail.
Therefore, it is recommended that this parameter
be greater than 80 ms.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The coding rate and MOS are affected.

The parameter modification has no


impact on the equipment.

The coding rate and MOS are affected.

The parameter modification has no


impact on the equipment.

The coding rate and MOS are affected.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

As the double antenna gain increases, the downlink


power increases; as the double antenna gain
decreases, the downlink power decreases.

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification does


not impact the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


corresponding neighboring 3G cell may be difficult
to become the candidate neighboring cell of the
serving cell. In this way, call drops may occur
because the handovers may not be performed
timely. If this parameter is set to a smaller value, a
call may be handed over to a neighboring 3G cell
with low signal strength, thus affecting voice
quality.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater or a smaller


value, the balance between the traffic volume on
the overlaid subcell and that on the underlaid
subcell may not be achieved.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a smaller value, the
handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a smaller value, the
handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the underlaid subcell; if
this parameter is set to a smaller value, congestion
may occur in the overlaid subcell.

The parameter modification has no


impact on the equipment.

The number of block retransmissions is decreased


and the throughput is increased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value,


congestion may occur in the underlaid subcell in a
short time; if this parameter is set to a greater
value, congestion in the overlaid subcell is difficult
to be relieved.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the underlaid subcell in a
short time; if this parameter is set to a smaller
value, congestion in the overlaid subcell is difficult
to be relieved.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, traffic


load on the underlaid subcell is increased, and thus
congestion may occur in the underlaid subcell. If
this parameter is set to a smaller value, traffic load
on the overlaid subcell is increased, and thus
congestion may occur in the overlaid subcell.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


congestion relieving speed in the underlaid subcell
is decreased. If this parameter is set to a smaller
value, traffic load on the overlaid subcell is
increased, and thus congestion may occur in the
overlaid subcell.

The parameter modification has no


impact on the equipment.

If this parameter is set to NO, the forced handover


and call delay caused by timeslot arrangement can
be avoided, but this may cause some TCHF-only
calls to fail.
If this parameter is set to Yes, calls may fail when
the timeslot arrangement fails and when the MS
does not select the TCHF in the concentric cell.

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion in the underlaid subcell may not be
relieved in time. If this parameter is set to a smaller
value, many calls may be handed over from the
underlaid subcell to the overlaid subcell in a shot
period, thus causing network congestion in the
overlaid subcell and handover failure.

The radio link should be reestablished after the parameter


modification.

If this parameter is set to OPEN, the speech quality


can be improved when the signal strength is low on
the air interface.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this timer is set to a greater value, channel


resources may be wasted, thus causing congestion.
If this timer is set to a smaller value, the success
rate of immediate assignment may decrease.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


effectiveness of power control is reduced, and thus
the network interference can not be reduced
effectively. If this parameter is set to a smaller
value, call drops may occur due to excessive power
control.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


effectiveness of power control is reduced, and thus
the network interference can not be reduced
effectively. If this parameter is set to a smaller
value, call drops may occur due to excessive power
control.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, call drops


may occur due to no suitable neighboring cell for
handover. If this parameter is set to a smaller value,
handover success rate may be decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The board should be reset to


None
validate the parameter modification.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter affects only the statistical result of


the counter "FER I (I = 0-7) Quality Level N".

The parameter modification has no


impact on the equipment.

This parameter affects only the statistical result of


the counter "FER I (I = 0-7) Quality Level N".

The parameter modification has no


impact on the equipment.

This parameter affects only the statistical result of


the counter "FER I (I = 0-7) Quality Level N".

The parameter modification has no


impact on the equipment.

This parameter affects only the statistical result of


the counter "FER I (I = 0-7) Quality Level N".

The parameter modification has no


impact on the equipment.

This parameter affects only the statistical result of


the counter "FER I (I = 0-7) Quality Level N".

The parameter modification has no


impact on the equipment.

This parameter affects only the statistical result of


the counter "FER I (I = 0-7) Quality Level N".

The parameter modification has no


impact on the equipment.

This parameter affects only the statistical result of


the counter "FER I (I = 0-7) Quality Level N".

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The radio link should be


reestablished after the parameter
modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to YES, the speech quality is


improved.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This technology prevents the loss of measurement


reports caused by the BSIC that cannot be decoded,
improves the system performance, and ensures the
radio handover success rate of the BSC6900.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The discontinuous transmission (DTX) function


allows a transmitter to stop power transmission in
the case of no voice transfer. This function has the
following benefits:
In the uplink: decreasing the power consumption of
the MS and reducing system interference
In the downlink: decreasing power consumption of
the BTS, reducing system interference, and
reducing intermodulation inside the BTS
From the network perspective, the inter-frequency
interference is reduced and the network quality is
improved.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The setting of this parameter must be consistent


with the actual frequency reuse pattern of the TRX.
Otherwise, the speech quality will be bad.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The discontinuous transmission (DTX) function


allows a transmitter to stop power transmission in
the case of no voice transfer. This function has the
following benefits:
In the uplink: decreasing the power consumption of
the MS and reducing system interference
In the downlink: decreasing power consumption of
the BTS, reducing system interference, and
reducing intermodulation inside the BTS
From the network perspective, the inter-frequency
interference is reduced and the network quality is
improved.

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the voice


quality may be decreased.
If this parameter is set to a smaller value, the
congestion relieving capability may be decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


duration of an AMR TCHF-TCHH handover is short
after the handover is triggered. Thus, few MSs can
be handed over from TCHF to TCHH, and the
congestion relieving capability is decreased.
If this parameter is set to a greater value, the
duration of an AMR TCHF-TCHH handover is long
after the handover is triggered. Thus, even the MSs
on the edge of the cell are handed over from TCHF
to TCHH, and the voice quality deteriorates.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time and network
congestion may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, network


congestion may occur because the handover may
not be performed timely.
If this parameter is set to a smaller value, the voice
quality may be decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


handover zone is enlarged in a short time, and thus
many MSs are handed over from TCHF to TCHH.
If this parameter is set to a greater value, the
handover zone is enlarged slowly and it takes a
long time to initiate a TCHF-TCHH handover. Thus,
and the congestion relieving capability is
decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a smaller value, network
congestion may occur because the handover may
not be performed timely.

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, only an


MS close to the overlaid subcell can be assigned
TCHHs. Thus, timeslots are wasted.
If this parameter is set to a smaller value, an MS of
bad quality on the edge of the overlaid subcell
cannot be handed over from TCHH to TCHF. Thus,
the voice quality of the call is decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


TCHH-to-TCHF handover cannot be performed in
time, thus the voice quality is decreased.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, only MSs


in the center area of the overlaid subcell can be
assigned TCHHs. Thus, timeslots are wasted and
the congestion relieving capability is decreased.
If this parameter is set to a smaller value, MSs on
the edge of the overlaid subcell also use the TCHH.
Thus, the voice quality of the call is decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a greater value, the
handover cannot be performed in time, and thus
the voice quality is decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the MS


takes a longer time to meet the conditions for
triggering the handover and the handover cannot
be performed in time. Thus, call drops may occur or
more handovers are triggered.
If this parameter is set to a smaller value, the MS
takes a shorter time to meet the conditions for
triggering the handover, and thus network
congestion may occur on the macro cell.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the macro cell.
If this parameter is set to a smaller value, the
handover cannot be performed in time. Thus, call
drops may occur or more handovers are triggered.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter limits the number of candidate


cells. If this parameter is set to a greater value,
some desired cells may be excluded from the
candidate cells and call drops may occur. If this
parameter is set to a smaller value, an unwanted
cell may become the candidate cell, thus leading to
handover failures or call drops.

The parameter modification has no


impact on the equipment.

This parameter limits the number of candidate


cells. If this parameter is set to a greater value,
some desired cells may be excluded from the
candidate cells and call drops may occur. If this
parameter is set to a smaller value, an unwanted
cell may become the candidate cell, thus leading to
handover failures or call drops.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to YES, the probability of MS


handover to the cell in the direction opposite to the
moving direction during fast handover is reduced.

The parameter modification has no


impact on the equipment.

If this parameter is set to a great value, there are


strict restrictions on the judgement of the MS
moving direction.

The parameter modification has no


impact on the equipment.

If this parameter is set to a great value, there are


strict restrictions on the judgement of the MS
moving direction.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value,


unnecessary handovers may be performed.
If this parameter is set to a greater value, call drops
may occur because the handover may not be
performed timely.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a too great value, the


handover cannot be performed timely, and the
speech quality is deteriorated or call drop occurs. If
this parameter is set to a too small value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time and call
drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, call drops


may occur because the handover may not be
performed timely.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, call drops


may occur because the handover may not be
performed timely.
If this parameter is set to a greater value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the underlaid subcell.
If this parameter is set to a smaller value, pingpong handovers may occur.

Not involved

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to YES, the probability that


the BTS transmits at full power increases. This
increases the interference but the handover
success rate also increases.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

Not involved

None

The cell should be activated after


the parameter modification.

If this parameter is set to "NO_FH", the antiinterference capability of the TRX is decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, it is


difficult for the MS to be handed over to the original
cell, thus leading to call drop when there is no
suitable neighboring cell.
If this parameter is set to a smaller value, the MS is
likely to be handed over to the original cell again,
thus leading to ping-pong handovers.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a too great value, the


handover cannot be performed timely, and the
speech quality is deteriorated or call drop occurs.
If this
parameter is set to a too small value, unnecessary
handovers may be performed.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a smaller value, the
handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a smaller value, the
handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a smaller value, call drops
may occur because the handover may not be
performed timely.

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value,


unnecessary handovers may be performed.
If this parameter is set to a greater value, call drops
may occur because the handover may not be
performed timely.

The cell should be activated after


the parameter modification.

None

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The discontinuous transmission (DTX) function


allows a transmitter to stop power transmission in
the case of no voice transfer. This function has the
following benefits:
In the uplink: decreasing the power consumption of
the MS and reducing system interference
In the downlink: decreasing power consumption of
the BTS, reducing system interference, and
reducing intermodulation inside the BTS
From the network perspective, the inter-frequency
interference is reduced and the network quality is
improved.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The discontinuous transmission (DTX) function


allows a transmitter to stop power transmission in
the case of no voice transfer. This function has the
following benefits:
In the uplink: decreasing the power consumption of
the MS and reducing system interference
In the downlink: decreasing power consumption of
the BTS, reducing system interference, and
reducing intermodulation inside the BTS
From the network perspective, the inter-frequency
interference is reduced and the network quality is
improved.

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


network interference is increased; if this parameter
is set to a greater value, congestion may occur in
the cell.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


network interference is increased; if this parameter
is set to a greater value, congestion may occur in
the cell.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the call


duration is prolonged; if this parameter is set to a
smaller value, the IBCA estimation accuracy is
reduced.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover duration is prolonged and thus the
handover cannot be performed in time; if this
parameter is set to a smaller value, the IBCA
estimation accuracy is reduced.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


network interference is increased; if this parameter
is set to a greater value, congestion may occur in
the cell.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover duration is prolonged and thus the
handover cannot be performed in time; if this
parameter is set to a smaller value, the IBCA
estimation accuracy is reduced.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


network interference is increased; if this parameter
is set to a greater value, congestion may occur in
the cell.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


accuracy of interference assessment in the IBCA
algorithm may be reduced; if this parameter is set
to a smaller value, the CPU occupancy for IBCA
algorithm is increased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover duration is prolonged and thus the
handover cannot be performed in time; if this
parameter is set to a smaller value, the IBCA
estimation accuracy is reduced.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


accuracy of interference assessment in the IBCA
algorithm may be reduced; if this parameter is set
to a smaller value, the CPU occupancy for IBCA
algorithm is increased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to YES, cell congestion may


occur when the interference is strong.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


network interference is increased; if this parameter
is set to a greater value, congestion may occur in
the cell.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value and


consequently there is a small number of requests
for SDCCHs, the SDCCHs of a cell are in idle state
and the TCH traffic volume during busy time is
decreased.
if this parameter is set to a smaller value and
consequently there is a large number of requests
for SDCCHs, the requests cannot be met and the
access success rate is decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this timer is set to a greater value, channel


resources may be wasted, thus causing congestion.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the callcompletion rate of MS increases but the BSC6900
load may also increase.
If this parameter is set to a smaller value, the
increase of the call completion rate is not obvious.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the callcompletion rate of MS increases but the BSC6900
load may also increase.
If this parameter is set to a smaller value, the
increase of the call completion rate is not obvious.

The parameter modification has no


impact on the equipment.

If this parameter is set to YES, the call completion


rate of the MS increases but the BSC6900 load also
increases.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


channel load may increase and the access success
rate may decrease.

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, channel


resources may be wasted, thus causing congestion.
If this parameter is set to a smaller value, the
handover success rate may decrease.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the traffic


volume during busy time may be decreased.
If this parameter is set to a smaller value, the voice
quality may be decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the traffic


volume during busy time may be decreased.
If this parameter is set to a smaller value, the voice
quality may be decreased.

The parameter modification has no


impact on the equipment.

If the value of this parameter is set too high, the


power load of other timeslots or cells is burdened.

The parameter modification has no


impact on the equipment.

The setting of this parameter affects the MOS.


When the C/I ratio is satisfactory, the coding
scheme of higher rate is recommended; otherwise,
the coding scheme of lower rate is recommended.

The parameter modification has no


impact on the equipment.

The setting of this parameter affects the MOS.


When the C/I ratio is satisfactory, the coding
scheme of higher rate is recommended; otherwise,
the coding scheme of lower rate is recommended.

The parameter modification has no


impact on the equipment.

The setting of this parameter affects the MOS.


When the C/I ratio is satisfactory, the coding
scheme of higher rate is recommended; otherwise,
the coding scheme of lower rate is recommended.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the underlaid subcell in a
short time; if this parameter is set to a smaller
value, congestion in the overlaid subcell is difficult
to be relieved.

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

Not involved

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

Not involved

None

The BTS should be reset to validate


the parameter modification.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, call drops


may occur.
If this parameter is set to a smaller value, handover
may be performed frequently and the signaling load
in the cell is increased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time. Thus, the
voice quality is decreased and call drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a smaller value, the
handover cannot be performed in time, thus the
voice quality is decreased or call drops may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a relatively small value,


the calls with low receive level are handed over to
other cells. Thus, the handover success rate is
decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a relatively great value,


congestion occurs to inter-RAT neighboring cells in a
short time. If this parameter is set to a relatively
small value, the congestion in the current cell
cannot be solved.

The parameter modification has no


impact on the equipment.

If this parameter is set to a relatively great value,


congestion occurs to inter-RAT neighboring cells in a
short time. If this parameter is set to a relatively
small value, the congestion in the current cell
cannot be solved.

The parameter modification has no


impact on the equipment.

If this parameter is set to a relatively small value,


the calls with low receive level are handed over to
other cells. Thus, the handover success rate is
decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the underlaid subcell;
If this parameter is set to a smaller value, handover
success rate may be decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this timer is set to a greater value, channel


resources may be wasted, thus causing congestion.
If this timer is set to a smaller value, the handover
success rate may decrease.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this timer is set to a greater value, channel


resources may be wasted, thus causing congestion.
If this timer is set to a smaller value, the handover
success rate may decrease.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a relatively great value,


the congestion in the current cell cannot be solved.
If this parameter is set to a relatively small value,
the calls with low receive level are handed over to
other cells. Thus, the handover success rate is
decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter adjusts traffic distribution.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the macro subcell;
If this parameter is set to a smaller value,
unnecessary handovers may be performed, thus
the voice quality is decreased and ping-pong
handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed, thus
the voice quality is decreased and ping-pong
handover may occur.
If this parameter is set to a smaller value,
congestion may occur in the macro subcell.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a too small value, the


corresponding cell may reject some handover
requests; thus the traffic congestion on the
neighboring cells with heavy traffic cannot be
relieved.
If this parameter is set to a
too great value, the corresponding cell may be
overloaded.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter adjusts traffic distribution.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter adjusts traffic distribution.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, it is


difficult for the MS to be handed over to the serving
cell, thus leading to call drop when there is no
suitable neighboring cell.
If this parameter is set to a smaller value, the MS is
likely to be handed over to the serving cell again,
thus leading to ping-pong handovers.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, it is


difficult for the MS to be handed over to the serving
cell, thus leading to call drop when there is no
suitable neighboring cell.
If this parameter is set to a smaller value, the MS is
likely to be handed over to the serving cell again,
thus leading to ping-pong handovers.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the neighboring cells in a
short time; if this parameter is set to a smaller
value, congestion in the serving cell is difficult to be
relieved.

The parameter modification has no


impact on the equipment.

This parameter adjusts traffic distribution.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter adjusts traffic distribution.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

When this parameter is set to "ON" and the level of


the channel request received by the BSC6900 is
low, the BSC6900 assigns only an underlaid channel
to the MS. In the case of heavy traffic, this may lead
to congestion in the underlaid subcell but can
prevent call drops due to the excessively low level
when the MS accesses an overlaid channel.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BSC6900 should be reset to


None
validate the parameter modification.
The parameter modification has no
impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

When this parameter is set to YES, the network KPIs


may be deteriorated.

The parameter modification has no


impact on the equipment.

When this parameter is set to YES, the network KPIs


may be deteriorated.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

Not involved

None

The transport path should be reestablished after the parameter


modification.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, call drops


may occur due to delayed power control; if this
parameter is set to a greater value, the power
control may be performed excessively, thus leading
to ping-pong power control.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, call drops


may occur or voice quality may be decreased due
to delayed handover; if this parameter is set to a
greater value, unnecessary handover may be
performed.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


algorithm cannot realize fast power control. If this
parameter is set to a greater value, the power
control may be performed excessively, thus leading
to poor quality, low level, and ping-pong power
control..

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


algorithm cannot realize fast power control. If this
parameter is set to a greater value, the power
control may be performed excessively, thus leading
to poor quality, low level, and ping-pong power
control..

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


algorithm cannot realize fast power control. If this
parameter is set to a greater value, the power
control may be performed excessively, thus leading
to poor quality, low level, and ping-pong power
control..

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the call


drop rate may increase; if this parameter is set to a
greater value, the speech quality may be affected.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, call drops


may occur due to delayed power control; if this
parameter is set to a greater value, the power
control may be performed excessively, thus leading
to ping-pong power control.

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

measurement results of six neighboring cells known


and permitted by the NCC at the bands with the
best signal regardless of the band at which the
neighboring cell is located.
If this parameter is set to 1, the MS reports the
measurement result of a neighboring cell known
and permitted by the NCC at each band with the
best signal (the band serving the current cell not
included). The MS reports the measurement result
of the neighboring cell at the band serving the
current cell in the redundant position. If the
redundant position is still available, the MS reports
the measurement results of other neighboring cells
regardless of the bands at which the neighboring
cells are located.
If this parameter is set to 2, the MS reports the
measurement results of two neighboring cell known
and permitted by the NCC at each band with the
best signal (the band serving the current cell not
included). The MS reports the measurement result
of the neighbor cell at the band serving the current
cell in the redundant position. If the redundant
position is still available, the MS reports the
measurement results of other neighboring cells
regardless of the bands at which the neighboring
cells are located.
If this parameter is set to 3, the MS reports the
measurement results of three neighboring cells
known and permitted by the NCC at each band with
the best signal (the band serving the current cell
not included). The MS reports the measurement
result of the neighboring cell at the band serving
the current cell in the redundant position. If the

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

In scenarios with heavy traffic, the network


performance can be improved if this switch is
turned on.

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

Not involved

Not involved

None

Not involved

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

Not involved

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter is used to limit the number of


candidate cells for handovers.
If this parameter is set to a greater value, some
desired cells may be excluded from the candidate
cells, thus leading to call drops.
If this parameter is set to a smaller value, an
unwanted cell may become a candidate cell, thus
leading to handover failures.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the idle


state of the current SDCCHs cannot be indicated
correctly and consequently the rollback of SDCCHs
immediately triggers adjustment and affects the
access success rate.
If this parameter is set to a larger value, the
channel allocation algorithm becomes less sensitive
and consequently the SDCCHs stay in idle state and
cannot be rolled back for a long period of time, thus
affecting the TCH traffic volume.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, some


desired cells may be excluded from the candidate
cells, thus leading to call drops.
If this parameter is set to a smaller value, an
unwanted cell may become a candidate cell, thus
leading to handover failures.

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

Not involved

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

If the value of this parameter is set too high, the


RSL congestion is likely to occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this timer is set to a greater value, the radio


resources are occupied for a too long time, thus
affecting the channel resource usage.
If this timer is set to a smaller value, the call
reestablishment success rate decreases.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter should be set as required: In the


areas where the traffic volume is low, this
parameter can be set to 4 or 7 to improve the
success rate of MS access. In the areas where
congestion occurs or in the micro cells where the
traffic volume is high, it is recommended this
parameter be set to 1.

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter limits the number of candidate


cells. If this parameter is set to a greater value,
some desired cells may be excluded from the
candidate cells and call drops may occur. If this
parameter is set to a smaller value, an unwanted
cell may become the candidate cell, thus leading to
handover failures or call drops.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Only the BTS3X in G3BTS32.30000.04.1130 or later


and the double-transceiver BTSs support the
LAPDm N200 parameter.
If this parameter is set to Yes, the BSC6900 sends
the LAPDm N200 parameter. If this parameter is set
to OFF, the BSC6900 does not send the LAPDm
N200 parameter.
If a BTS does not support this parameter, the
parameter should be set to No. Otherwise, the BTS
cannot be initialized.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

When this parameter is set to ENABLE, the MOS can


be increased in a call between MSs.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The most significant three bits of BSIC for all cells


map with the NCC. NCC Permitted should be set
properly to avoid too many call drops. The MS does
not report the information on the neighboring cells
in the network whose corresponding NCC bit is set
to 0. Thus, this parameter should be set properly.
Otherwise, an MS during an ongoing call cannot
perform normal handover and a cross-coverage call
drop occurs. For details, see GSM Rec. 05. 08.
During an ongoing call, the MS reports to the BTS
the signal information on neighboring cells. A report
covers a maximum of six cells. Thus, the MS should
report those possible target cells, rather than
selecting cells only based on the signal level.
Generally, the MS does not report the information
on the cells belonging to other GSM PLMNs.
This function enables the MS to measure only those
specified cells. This parameter specifies the codes
of the NCCs to be measured by the MS.
On the SCH, the system constantly transmits the
BSIC, the first three bits of which indicate the NCC.
Thus, the MS needs to compare only this parameter
with the adjacent NCCs measured. Then, the MS
reports the matched NCCs to the BTS and discards
others.
The setting of this parameter affects only those MSs
during conversation, as well as boundary
handovers.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value,


handovers are performed frequently; if this
parameter is set to a greater value, handovers
cannot be performed timely, thus leading to call
drops.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to YES, FR calls can be


switched into HR calls to relieve the network
congestion, but the voice quality is decreased; if
this parameter is set to NO, FR calls cannot be
switched into HR calls, that is, network congestion
cannot be relieved through the handover from TCHF
to TCHH.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover margin is increased in a short period and
many MSs are handed over from TCHF to TCHH,
thus affecting the voice quality.
If this parameter is set to a smaller value, the
handover margin is enlarged slowly and it takes a
long time to initiate a TCHF-TCHH handover. Thus,
the network congestion cannot be relieved in time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, only MSs


in the center of the cell can meet the handover
condition. Thus, the network congestion cannot be
relieved in time.
If this parameter is set to a smaller value, MSs at
the edge of the cell can also meet the handover
condition, thus affecting the voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover margin is increased in a short period and
many MSs are handed over from TCHF to TCHH,
thus affecting the voice quality.
If this parameter is set to a smaller value, the
handover margin is enlarged slowly and it takes a
long time to initiate a TCHF-TCHH handover. Thus,
network congestion cannot be relieved in time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, MSs at


the edge of the cell can also meet the handover
condition, thus affecting the voice quality.
If this parameter is set to a smaller value, only MSs
in the center of the cell can meet the handover
condition. Thus, the network congestion cannot be
relieved in time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, MSs with


poor quality can also meet the handover condition,
thus affecting the voice quality.
If this parameter is set to a smaller value, little MSs
can meet the handover condition. Thus, the
network congestion cannot be relieved in time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the calls


cannot be handed over to TCHH in a short period
when the traffic volume is increased greatly. Thus,
the network congestion cannot be relieved in time.
If this parameter is set to a smaller value, calls are
handed over to TCHH unnecessarily, thus causing
MOS loss of the customer.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, only MSs


in the center of the cell use the TCHH, thus leading
to timeslot waste and the network congestion
cannot be relieved in time. If this parameter is set
to a smaller value, MSs at the edge of the cell and
with poor quality also cannot be handed over to the
TCHF, thus affecting the voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, MSs at


the edge of the cell and with poor quality also
cannot be handed over to the TCHF, thus affecting
the voice quality. If this parameter is set to a
smaller value, only MSs in the center of the cell use
the TCHH, thus leading to timeslot waste and the
network congestion cannot be relieved in time.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, handover


cannot be triggered even when the quality is poor,
thus affecting the voice quality; if this parameter is
set to a smaller value, handover is triggered even
when the quality is good, thus the network
congestion cannot be relieved in time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, calls are


handed over to TCHH unnecessarily, thus causing
MOS loss of the customer; if this parameter is set to
a greater value, TCHF-TCHH handover is performed
only when the traffic volume is high, thus network
congestion may occur.

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The handover decision is allowed only when the


uplink receive quality is greater than or equal to the
value of this parameter. Therefore, if this parameter
is set to a greater value, the handovers due to nodownlink measurement report cannot be triggered.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter should be set to a small value


because the signaling channel seizure duration is
shorter than the traffic channel seizure duration for
the MS.

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the underlaid subcell; if
this parameter is set to a smaller value, assignment
success rate may be decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


assignment success rate may be decreased; if this
parameter is set to a smaller value, congestion may
occur in the underlaid subcell.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the overlaid subcell; if this
parameter is set to a smaller value, congestion may
occur in the underlaid subcell.

The parameter modification has no


impact on the equipment.

If the value of this parameter is set too small,


frequent handovers are likely to occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the overlaid subcell; if this
parameter is set to a smaller value, congestion may
occur in the underlaid subcell.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the overlaid subcell in a
short time; if this parameter is set to a smaller
value, congestion in the underlaid subcell is difficult
to be relieved.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion in the underlaid subcell is difficult to be
relieved; if this parameter is set to a smaller value,
congestion may occur in the overlaid subcell in a
short time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the overlaid subcell in a
short time; if this parameter is set to a smaller
value, congestion in the underlaid subcell is difficult
to be relieved.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the underlaid subcell; if
this parameter is set to a smaller value, congestion
may occur in the overlaid subcell.

Not involved

None

Not involved

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the underlaid subcell; if
this parameter is set to a smaller value, congestion
may occur in the overlaid subcell.

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the BTS


frequently reports overload indication messages to
the BSC6900. As a result, the BSC6900 frequently
reports overload indication messages to the MSC
and thus the MSC may initiate flow control. If this
parameter is set to a greater value, the BTS sends
overload indication messages to the BSC6900 only
when a large number of MSs access the network
and when the system resources are insufficient.
Therefore, the access requests on the RACH and all
the messages on the PCH are discarded.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Properly setting this parameter can increase the


paging success rate. If this parameter is set to a
greater value, paging overload may occur and the
paging success rate may decrease.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time and call
drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed; if this
parameter is set to a smaller value, handovers may
not be performed in time and call drops may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The transport path should be reestablished after the parameter


modification.

None

The transport path should be reestablished after the parameter


modification.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the target


cell for the previous handover will not be selected
for the next handover, but the probability of call
drop increases. If this parameter is set to a smaller
value, the probability of handover failure increases.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

If this parameter is set to "YES", the user with high


QoS requirement may occupy a great number of PS
resources. In this case, the remaining resources for
other users reduce. As a result, the KPIs for these
users become bad.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a lower value, the paging


success rate may decrease.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

The MS calculates C1 and C2 of the serving cell at a


minimum interval of 5s. When necessary, the MS
re-calculates C1 and C2 of all non-serving cells
(neighboring cells). The MS constantly checks
whether a cell reselection is required by checking
following conditions:
Whether the path loss (C1) of the current serving
cell drops below 0 within 5s. If yes, the path loss is
too large.
C2 of an appropriate non-serving cell exceeds that
of the serving cell in 5s and the following conditions
are met:
The C2 of a new cell in another LAC minus CRH
(broadcast in the system information 3 and 4 of the
serving cell) exceeds C2 of the serving cell in 5s.
A cell reselection is performed in the last 15s, and
the C2 of the new cell minus 5 dB constantly
exceeds the C2 of the serving cell in 5s.
A better cell exists if the above conditions are met.
If a better cell exists, the MS reselects a cell, and
does not select the previous cell within 5s.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The transport path should be reestablished after the parameter


modification.

None

The transport path should be reestablished after the parameter


modification.

None

The BTS should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The BTS should be reset to validate


the parameter modification.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

Not involved

Not involved

Not involved

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

If this parameter is set to "YES", the delay caused


by cell reselection decreases.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the call


drop rate decreases but the traffic volume and
paging success rate are affected.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

The setting of this parameter affects the GSM Phase


II MS.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification does


not impact the equipment.

None

The parameter modification does


not impact the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If the value of this parameter is set inappropriately


high or small, the BTS cabinet top output power is
inconsistent with the TRX output power.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers between micro cells are
performed, thus affecting the voice quality. If this
parameter is set to a smaller value, congestion may
occur in macro cells.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in macro cells. If this
parameter is set to a smaller value, unnecessary
handovers between micro cells are performed, thus
affecting the voice quality.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, downlink


power insufficiency may not be solved in time, thus
leading to call drops.
If this parameter is set to a smaller value,
unnecessary handovers may be performed, thus
the voice quality is decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed, thus
the voice quality is decreased.
If this parameter is set to a smaller value, downlink
power insufficiency may not be solved in time, thus
leading to call drops.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


algorithm cannot realize fast power control. If this
parameter is set to a greater value, the power
control may be performed excessively, thus leading
to poor quality, low level, and ping-pong power
control.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the call


drop rate decreases but the traffic volume and
paging success rate are affected.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


random access success rate may decrease.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the BTS


frequently sends the overload messages to the
BSC6900. Thus, the system resource usage
decreases and MSs are difficult to access the
network.
If this parameter is set to a greater value, the BTS
sends an overload message to the BSC6900 at a
long interval. Thus, system faults may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


allowable error rate for the random access signal is
high and an MS can easily access the network;
however, the error report rate is high. If this
parameter is set to a greater value, the error report
rate of the MS is low but the MS cannot easily
access the network.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

When this parameter is set to on, the MOS of a MSinitiated and MS-terminated call is improved.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to YES, the BSC6900


initiates a reassignment when receiving an
assignment failure message over the Um interface.
This helps increase the call completion rate and
improve the QoS of the network. The successful
reassignment, however, results in an increase in the
access delay of MSs and the load of the BSC6900.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, too many


channels may be reserved for the users with high
priority, and the users with low priority may be
failed to access channels. If this parameter is set to
a smaller value, channels reserved for the users
with high priority may be insufficient.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the radio


resource status is reported too frequently, thus
increasing the load of the BSC6900.
If this parameter is set to a greater value, the radio
resource status is not immediately reported and
thus the BSC6900 cannot handle the interference to
the BTS in time.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the radio


link is vulnerable to failure, thus call drops are likely
to occur.
If this parameter is set to a greater value, the MS
may not release the connection for a long time,
thus decreasing the resource usage. The parameter
is valid in the downlink.

The BSC should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, call drops


may occur due to no suitable neighboring cell for
handover. If this parameter is set to a smaller value,
handover success rate may be decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, some


desired cells may be excluded from the candidate
cells, thus leading to call drops.
If this parameter is set to a smaller value, an
unwanted cell may become a candidate cell, thus
leading to handover failures.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

When this parameter is set to on, the MOS of a MSinitiated and MS-terminated call is improved.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the call


drop rate decreases but the traffic volume and
paging success rate are affected.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this switch is set to ON, the call access delay may


be prolonged, but the performance of the
algorithms in which the SDCCH MRs are used are
enhanced.

The parameter modification has no


impact on the equipment.

The greater the value of this parameter is, the


longer the call access duration is, the MRs are
filtered more completely. Generally, you are advised
to set this parameter to a value smaller than 20.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this function is enabled after encryption is


enabled, the network security can be improved.

The parameter modification has no


impact on the equipment.

The TRX is shut down automatically, and the


capacity of the cell is decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time and call
drops may occur. If this parameter is set to a
smaller value, unexpected handovers may be
performed due to incorrect MR when the call is
initially set up, thus affecting handover success
rate.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover to micro cells becomes difficult, and
congestion may occur in macro cells. If this
parameter is set to a smaller value, unnecessary
handovers are performed, thus affecting the voice
quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover to micro cells becomes difficult, and
congestion may occur in macro cells. If this
parameter is set to a smaller value, unnecessary
handovers are performed, thus affecting the voice
quality.

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

When the neighboring 3G cell is configured and the


inter-system cell reselection is enabled, the MS
cannot receive the 2Quater message and thus
cannot be reselected to the neighboring 3G cell if
this parameter is set to NO.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BSC should be reset to validate


the parameter modification.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

This parameter can be used to control network load


based on the MS access classes, thus preventing
some MSs from accessing the network. It is
recommended that this parameter be not used.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover to micro cells becomes difficult, and
congestion may occur in macro cells.
If this parameter is set to a smaller value, more
handovers may be performed, thus the voice
quality is decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover to micro cells becomes difficult, and
congestion may occur in macro cells.
If this parameter is set to a smaller value, more
handovers may be performed, thus the voice
quality is decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The BTS should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification does


not impact the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, it is


difficult for the MS to be handed over to the original
cell, thus leading to call drop when there is no
suitable neighboring cell. If this parameter is set to
a smaller value, the MS is likely to be handed over
to the original cell again, thus leading to ping-pong
handovers.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, it is


difficult for the MS to be handed over to the original
cell, thus leading to call drop when there is no
suitable neighboring cell. If this parameter is set to
a smaller value, the MS is likely to be handed over
to the original cell again, thus leading to ping-pong
handovers.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If timer T200 is set to a smaller value, the transmit


end may mistakenly regard that the link is faulty
and the data transmission fails before the transmit
end receives a response from the peer end. If timer
N200 is set to a smaller value, the number of data
retransmissions is reduced and the success rate of
transmission is reduced. If timers T200 and N200
are set to greater values, the channels are seized
all along when the link is faulty. Thus, resources are
wasted.

The parameter modification has no


impact on the equipment.

If timer T200 is set to a smaller value, the transmit


end may mistakenly regard that the link is faulty
and the data transmission fails before the transmit
end receives a response from the peer end. If timer
N200 is set to a smaller value, the number of data
retransmissions is reduced and the success rate of
transmission is reduced. If timers T200 and N200
are set to greater values, the channels are seized
all along when the link is faulty. Thus, resources are
wasted.

The parameter modification has no


impact on the equipment.

If timer T200 is set to a smaller value, the transmit


end may mistakenly regard that the link is faulty
and the data transmission fails before the transmit
end receives a response from the peer end. If timer
N200 is set to a smaller value, the number of data
retransmissions is reduced and the success rate of
transmission is reduced. If timers T200 and N200
are set to greater values, the channels are seized
all along when the link is faulty. Thus, resources are
wasted.

The parameter modification has no


impact on the equipment.

If timer T200 is set to a smaller value, the transmit


end may mistakenly regard that the link is faulty
and the data transmission fails before the transmit
end receives a response from the peer end. If timer
N200 is set to a smaller value, the number of data
retransmissions is reduced and the success rate of
transmission is reduced. If timers T200 and N200
are set to greater values, the channels are seized
all along when the link is faulty. Thus, resources are
wasted.

The parameter modification has no


impact on the equipment.

If timer T200 is set to a smaller value, the transmit


end may mistakenly regard that the link is faulty
and the data transmission fails before the transmit
end receives a response from the peer end. If timer
N200 is set to a smaller value, the number of data
retransmissions is reduced and the success rate of
transmission is reduced. If timers T200 and N200
are set to greater values, the channels are seized
all along when the link is faulty. Thus, resources are
wasted.

The parameter modification has no


impact on the equipment.

If timer T200 is set to a smaller value, the transmit


end may mistakenly regard that the link is faulty
and the data transmission fails before the transmit
end receives a response from the peer end. If timer
N200 is set to a smaller value, the number of data
retransmissions is reduced and the success rate of
transmission is reduced. If timers T200 and N200
are set to greater values, the channels are seized
all along when the link is faulty. Thus, resources are
wasted.

The parameter modification has no


impact on the equipment.

If timer T200 is set to a smaller value, the transmit


end may mistakenly regard that the link is faulty
and the data transmission fails before the transmit
end receives a response from the peer end. If timer
N200 is set to a smaller value, the number of data
retransmissions is reduced and the success rate of
transmission is reduced. If timers T200 and N200
are set to greater values, the channels are seized
all along when the link is faulty. Thus, resources are
wasted.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


paging success rate increases but the load on the
SDCCH also increases, thus causing congestion on
the SDCCH.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time and call
drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time and call
drops may occur. If this parameter is set to a
smaller value, the coverage area of the cell is
reduced, and the traffic volume on the cell may be
decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, network


congestion may occur in the cell; if this parameter
is set to a smaller value, TCHHs are allocated even
when the traffic volume on the cell is light, this
affects the voice quality.

The parameter modification has no


impact on the equipment.

When this parameter is set to a large value, the


values of the new counters TCH call drops (DL FER)
and TCH call drops (UL FER and DL FER) are
reduced. When this parameter is set to a small
value, the values of the two counters are increased.
The overall number of call drops, however, remains
unchanged and the performance of other counters
is not affected.

The parameter modification has no


impact on the equipment.

When this parameter is set to a large value, the


values of the new counters TCH call drops (DL
receive level) and TCH call drops (UL receive level)
are increased. When this parameter is set to a small
value, the values of the two counters are reduced.
The overall number of call drops, however, remains
unchanged and the performance of other counters
is not affected.

The parameter modification has no


impact on the equipment.

When this parameter is set to a large value, the


values of the new counters TCH call drops (DL
receive quality) and TCH call drops (UL receive
quality and DL receive quality) are reduced. When
this parameter is set to a small value, the values of
the two counters are increased. The overall number
of call drops, however, remains unchanged and the
performance of other counters is not affected.

The parameter modification has no


impact on the equipment.

When this parameter is set to a large value, the


values of the new counters TCH call drops (UL FER)
and TCH call drops (UL FER and DL FER) are
reduced. When this parameter is set to a small
value, the values of the two counters are increased.
The overall number of call drops, however, remains
unchanged and the performance of other counters
is not affected.

The parameter modification has no


impact on the equipment.

When this parameter is set to a large value, the


values of the new counters TCH call drops (UL
receive level) and TCH call drops (UL receive level
and DL receive level) are increased. When this
parameter is set to a small value, the values of the
two counters are reduced. The overall number of
call drops, however, remains unchanged and the
performance of other counters is not affected.

The parameter modification has no


impact on the equipment.

When this parameter is set to a large value, the


values of the new counters TCH call drops (UL
receive quality) and TCH call drops (UL receive
quality and DL receive quality) are reduced. When
this parameter is set to a small value, the values of
the two counters are increased. The overall number
of call drops, however, remains unchanged and the
performance of other counters is not affected.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time and call
drops may occur. If this parameter is set to a
smaller value, unexpected handovers may be
performed due to incorrect MR when the call is
initially set up, thus affecting handover success
rate.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


handover frequency is higher.

The parameter modification has no


impact on the equipment.

If this parameter is set to ON, the calls are handed


over on schedule. This increases the load of the
BSC6900 but improves the network security.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the halfrate channels are assigned to the MS only when the
channel seizure ratio of underlaid subcell is very
high. Insufficient half-rate channels can be assigned
to the MS. Thus, the capacity of the BSC is reduced.
If this parameter is set to a smaller value, the halfrate channels are assigned to the MS only when the
channel seizure ratio of underlaid subcell is very
low. The calls use the half-rate channel even if there
are enough full-rate channels, which influences the
voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the halfrate channels are assigned to the MS only when the
channel seizure ratio of overlaid subcell is very
high. Insufficient half-rate channels can be assigned
to the MS. Thus, the capacity of the BSC is reduced.
If this parameter is set to a smaller value, the halfrate channels are assigned to the MS only when the
channel seizure ratio of overlaid subcell is very low.
The calls use the half-rate channel even if there are
enough full-rate channels, which influences the
voice quality.

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The radio link should be


reestablished after the parameter
modification.

If both TFO and AEC functions are enabled and the


acoustic echo is detected, the TFO is disabled to
cancel the echo so that the speech quality can be
improved.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the BCCH


may idle while non-BCCHs are congested, thus
affecting the traffic volume during busy times.
If this parameter is set to a smaller value, the
assignment of the BCCH may fail, and thus the
access success rate may be decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


assignment of the BCCH may fail, and thus the
handover success rate may be decreased.
If this parameter is set to a smaller value, the BCCH
may idle while non-BCCHs are congested, thus
affecting the traffic volume during busy times.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the BCCH


may idle while non-BCCHs are congested, thus
affecting the traffic volume during busy times and
the access success rate.
If this parameter is set to a smaller value,
unnecessary handovers may be performed, thus
the voice quality is decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, cell


congestion may be difficult to be relieved, thus
affecting the traffic volume during busy times and
the access success rate. If this parameter is set to a
smaller value, handover success rate may be
decreased.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, it is


difficult for the MS to be handed over to the original
cell, thus leading to call drop when there is no
suitable neighboring cell. If this parameter is set to
a smaller value, the MS is likely to be handed over
to the original cell again, thus leading to ping-pong
handovers.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, call drop


rate may be increased and congestion may occur in
the overlaid subcell; if this parameter is set to a
smaller value, handover success rate may be
decreased.

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, it is


difficult for the MS to be handed over to the original
cell, thus leading to call drop when there is no
suitable neighboring cell. If this parameter is set to
a smaller value, the MS is likely to be handed over
to the original cell again, thus leading to ping-pong
handovers.

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, it is


difficult for the MS to be handed over to the original
cell, thus leading to call drop when there is no
suitable neighboring cell. If this parameter is set to
a smaller value, the MS is likely to be handed over
to the original cell again, thus leading to ping-pong
handovers.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the underlaid subcell; if
this parameter is set to a smaller value, handover
success rate may be decreased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The BTS should be reset to validate


the parameter modification.

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

Not involved

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The transport path should be reestablished after the parameter


modification.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

When this parameter is enabled, the fast flux


monitoing frequency is increased, and the channel
allocation can be adjusted more quickly to adapt to
the service type. Thus, the terminal throughput and
BSC PS resource usage can be increased.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If the number of RACH conflicts in a cell is small, T


should be set to a great value. If the number of
RACH conflicts in a cell is large, T should be set to a
small value. The increase in T and S prolongs the
access time of an MS, thus affecting the access
performance of the whole network. Therefore,
appropriate values should be selected for T and S.
When the network traffic is heavy, the success rate
of immediate assignment is low if the sum of S and
T is low. Thus, the value of T should be properly
adjusted to make the sum of S and T great.

The parameter modification has no


impact on the equipment.

The parameter modification impacts the covered


range of cell.

The parameter modification has no


impact on the equipment.

The parameter modification impacts the covered


range of cell.

The parameter modification has no


impact on the equipment.

The parameter modification impacts the covered


range of cell.

The parameter modification has no


impact on the equipment.

The parameter modification impacts the covered


range of cell.

The parameter modification has no


impact on the equipment.

The parameter modification impacts the covered


range of cell.

The parameter modification has no


impact on the equipment.

The parameter modification impacts the covered


range of cell.

The parameter modification has no


impact on the equipment.

The parameter modification impacts the covered


range of cell.

The parameter modification has no


impact on the equipment.

The parameter modification impacts the covered


range of cell.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The cell should be activated after


the parameter modification.

None

The BSC should be reset to validate


the parameter modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


down power adjustment may not be performed
when the uplink quality is good, thus causing power
waste and increasing the interference. If this
parameter is set to a relatively small value, down
power adjustment may be performed when the
uplink quality is poor. In this case, call drops may
occur.

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


up power adjustment may be performed when the
uplink quality is good, thus causing power waste
and increasing the interference. If this parameter is
set to a relatively small value, up power adjustment
may not be performed when the uplink quality is
poor. In this case, call drops may occur.

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


down power adjustment may not be performed
when the uplink quality is good, thus causing power
waste and increasing the interference. If this
parameter is set to a relatively small value, down
power adjustment may be performed when the
uplink quality is poor. In this case, call drops may
occur.

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


up power adjustment may be performed when the
uplink quality is good, thus causing power waste
and increasing the interference. If this parameter is
set to a relatively small value, up power adjustment
may not be performed when the uplink quality is
poor. In this case, call drops may occur.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time and call
drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed.
If this parameter is set to a smaller value, the
handover cannot be performed in time and call
drops may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, call drops


may occur due to delayed handover; if this
parameter is set to a greater value, unnecessary
handover may be performed, thus affecting the
voice quality.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


down power adjustment may not be performed
when the uplink quality is good, thus causing power
waste and increasing the interference. If this
parameter is set to a relatively small value, down
power adjustment may be performed when the
uplink quality is poor. In this case, call drops may
occur.

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


up power adjustment may be performed when the
uplink quality is good, thus causing power waste
and increasing the interference. If this parameter is
set to a relatively small value, up power adjustment
may not be performed when the uplink quality is
poor. In this case, call drops may occur.

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


down power adjustment may not be performed
when the uplink quality is good, thus causing power
waste and increasing the interference. If this
parameter is set to a relatively small value, down
power adjustment may be performed when the
uplink quality is poor. In this case, call drops may
occur.

The parameter modification has no


impact on the equipment.

If the parameter is set to a relatively great value,


up power adjustment may be performed when the
uplink quality is good, thus causing power waste
and increasing the interference. If this parameter is
set to a relatively small value, up power adjustment
may not be performed when the uplink quality is
poor. In this case, call drops may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a relatively small value,


the fast power control on the uplink cannot be
implemented. If this parameter is set to a relatively
great value, the power control may be performed
excessively on the uplink, thus leading to poor
quality, low level, and ping-pong power control.

The parameter modification has no


impact on the equipment.

If this parameter is set to a relatively small value,


call drops may occur due to delayed power control
in the uplink. If this parameter is set to a relatively
great value, the power control may be performed
excessively on the uplink, thus leading to ping-pong
power control.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value,


downward power control is not performed when the
signal quality is good, thus causing power waste
and increasing the interference. If this parameter is
set to a greater value, downward power control is
performed even though the signal quality is bad,
thus affecting the speech quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, upward


power control may not be performed when the
voice quality is bad, thus affecting the voice quality.
If this parameter is set to a smaller value, upward
power control may be performed when the voice
quality is good, thus causing the power waste and
increasing the interference.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, handover


may not be performed when the uplink voice
quality is bad, thus leading to call drops. If this
parameter is set to a smaller value, unnecessary
handovers may be performed, thus affecting the
voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


handovers due to bad uplink quality may increase,
thus decreasing the handover success rate. If this
parameter is set to a greater value, handovers due
to bad uplink quality are less possible to occur, thus
increasing the call drop rate.

The parameter modification has no


impact on the equipment.

If this parameter is set to a smaller value, the


handovers due to bad uplink quality may increase,
thus decreasing the handover success rate. If this
parameter is set to a greater value, handovers due
to bad uplink quality are less possible to occur, thus
increasing the call drop rate.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


downward power control may not be performed
when the voice quality is good, thus causing the
power waste and increasing the interference. If this
parameter is set to a smaller value, downward
power control may be performed when the voice
quality is bad, thus affecting the voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, upward


power control may be performed when the voice
quality is good, thus causing the power waste and
increasing the interference. If this parameter is set
to a smaller value, upward power control may not
be performed when the voice quality is bad, thus
affecting the voice quality.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


downward power control may not be performed
when the voice quality is good, thus causing the
power waste and increasing the interference. If this
parameter is set to a smaller value, downward
power control may be performed when the voice
quality is bad, thus affecting the voice quality.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, upward


power control may be performed when the voice
quality is good, thus causing the power waste and
increasing the interference. If this parameter is set
to a smaller value, upward power control may not
be performed when the voice quality is bad, thus
affecting the voice quality.

The parameter modification has no


impact on the equipment.

The coding rate and MOS are affected.

The parameter modification has no


impact on the equipment.

The coding rate and MOS are affected.

The parameter modification has no


impact on the equipment.

The coding rate and MOS are affected.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, call drops


may occur due to no suitable neighboring cell for
handover. If this parameter is set to a smaller value,
handover success rate may be decreased.

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

Not involved

Not involved

The parameter modification has no


impact on the equipment.

None

The transport path should be reestablished after the parameter


modification.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, the


handover cannot be performed in time and call
drops may occur.
If this parameter is set to a smaller value,
unnecessary handovers may be performed, thus
affecting the voice quality.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


unnecessary handovers may be performed, thus
affecting the voice quality.
If this parameter is set to a smaller value, the
handover cannot be performed in time and call
drops may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the underlaid subcell.
If this parameter is set to a smaller value, pingpong handovers may occur.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion in the underlaid subcell is difficult to be
relieved; if this parameter is set to a smaller value,
congestion may occur in the overlaid subcell in a
short time.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value,


congestion may occur in the overlaid subcell in a
short time; if this parameter is set to a smaller
value, congestion in the underlaid subcell is difficult
to be relieved.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a high value and the


VGCS has priority, public network services are likely
to suffer from insufficient channels. Thus, this
parameter needs to be set according to the actual
service requirements.

The parameter modification has no


impact on the equipment.

When preemption conditions are met, public


network services can preempt channels of the
VGCS if this parameter is set to Public Network
First; the VGCS can preempt channels of public
network services if this parameter is set to VGCS
First.

The parameter modification has no


impact on the equipment.

If this parameter is set to a high value and the


VGCS has priority, public network services are likely
to suffer from insufficient channels. Thus, this
parameter needs to be set according to the actual
service requirements.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

Not involved

Not involved

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, channel


resources may be wasted, thus causing congestion.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, channel


resources may be wasted, thus causing congestion.

The parameter modification has no


impact on the equipment.

If this parameter is set to a greater value, channel


resources may be wasted, thus causing congestion.

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

The parameter modification has no


impact on the equipment.

None

Not involved

None

The parameter modification has no


impact on the equipment.

None

Introduced in Version

Attribute

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Transport

BSC6900 V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

BSC6900 V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Equipment

BSC6900 V900R011

Equipment

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Versions earlier than BSC6900


V900R011

Radio

Versions earlier than BSC6900


V900R011

Transport

Versions earlier than BSC6900


V900R011

Equipment

Vous aimerez peut-être aussi