QUICK GUIDE

Wiring for analogue extensions module


With the optional analogue extension module added, the XDi now has 2
analogue inputs which can be configured as voltage and current inputs. The
wiring must be done according to the table below.
Voltage and current connection
Teminal no
Signal
+
11
1
Voltage input +/-30 V
Voltage input +/- 2 V
9
10
Current input +/- 2 mA
9
8
Current input +/- 20 mA
7

Voltage input +/-30 V


Voltage input +/- 2 V
Current input +/- 2 mA
Current input +/- 20 mA
Dimmer input 030 V (can be used as extra input
+/-30 V)
REF out

Input
Analogue port 1

XDi, FleXible Display indicator

DEIFs XDi series is a compact, easy-to-install,


versatile and user-friendly revolution
in illuminated bridge instrumentation

Analogue port 2

(Analogue port 3)

Note 1: Terminal 1, common, is used for input DIMM, REF, HV1+ and HV2+.
Note 2: Only one measurement (voltage or current) range from each analog port can
be selected.

Document no.: 4189350046C

Power up the First Time


When power is applied to the XDi, it can take 45 seconds before the indicator has been fully initialised and the unit is operational. When the XDi has not
been configured, a start-up wizard will guide you through the settings of the
indicator to ensure a correct setup of the XDi.

The menu is divided into 2 panes. The left pane shows information for the
selected menu or settings. In the right pane, the current menu is shown with
a highlighted blue arrow.
To navigate through the menus, the two physical buttons up and down is
used. Press the OK physical button to select a menu or value.

Configuration of the XDi


The start-up wizard ensures an easy configuration of the XDi and gives the
ability to select virtual indicator and setup profiles from the built-in library.
You can choose to configure the XDi before the installation or after the XDi
is placed in the system.
If an already configured XDi has to be reconfigured, e.g. with a new virtual
indicator or CAN ID, the Restart Setup Wizard must be selected in the
install menu. From the install menu, it is also possible to make adjustment
to the indicator and input. This is described in details in the User Reference
Manual.

CANopen

Accessing the menus


The 4 buttons used for control are placed under the front frame. To remove
the front frame, insert the tip of your finger in the lower right corner and lift
up the front frame. The different menus can be accessed by pushing 2 of
the buttons in the combination below.
Menu/Function
Surveyor Info
Master Reset
User Menu
Install menu1

Button 1

Button 2

Button 3

Button 4

2 buttons must be pressed simultaneously for 5 seconds to activate the


functions.
Note: Button 1 is placed to the left.

Only to be accessed from User Menu

For more information on the addresses used to set up data to and from the
XDi, please refer to the User Reference Manual or the XDi-Net/CANopen
Reference Manual.
Wiring of XDi
Type
Connector 1

Dill switch 1
Dill switch 2
Connector 2

Terminal
no.
1
2
3
4
5
6
7
8
9
10

Signal

Marking

Remark

CAN 1

CAN 1 GND
CAN 1 LOW
CAN 1 HIGH
+24V DC
0V
CAN 1 Term.
CAN 2 Term.
CAN 2 GND
CAN 2 LOW
CAN 2 HIGH
+24 V DC
0V

Common (dont connect)

Supply
Voltage
ON/OFF
On/OFF
CAN 2
Supply
Voltage

Standard power input 1


120 termination
120 termination
Common (dont connect)
Standard power input 2

By default, the termination is set to OFF. Both ends of the CANbus cable
should be terminated,
Please note, that only 2 terminations must be activated (set ON) at a
time on a CANbus network.

When the cables and connectors are mounted on the XDi, the cables should
be relieved using a cable tie which is easily inserted in the two small slots
above the connectors.
Picture can be seen on next page.