The current optical fiber communication system operates in two low loss
window: 1.55 mu m band and 1.31 mu m band. Select a different doping
elements, can make the amplifier working in different window.
the lifetime of the excited state is much longer, which is called the metastable
state. When the Er3+ return from the transition of metastable excited state to
ground state, the extra energy into fluorescence radiation, the wavelength of
light radiation is determined by the metastable and energy level difference of
base stations. In the 1550nm band, under the constant action of the pumping
source, the metastable excited state of Er3+ is accumulated, and the number
of the ions can exceed the number of ions in the ground state. When the
number of particles in the high-energy state exceeds the number of particles,
the inversion state of the particle number is reached.Only in this state can
there be light amplification.Such as the photon energy of incident light signal is
equal to the energy difference between the ground state and metastable,
namely the light wavelength and the wavelength of the radiation of light are the
same, it will also cause by the absorption of ground state and metastable leaps
and metastable - the launch of the ground state transition, transition to absorb
light energy absorption, launch transition energy, the size of the absorption
and emission light energy from the ground state and metastable is proportional
to the particle density.Because of the inversion of the number of particles, the
total effect is that the emission of the light exceeds the absorbed light, which
makes the incident light enhanced and the optical amplification is obtained.
Usage Tips
Troubleshooting
Fiber amplifier, the panel displays and the actual output is
synchronized, if panel display is normal, then optical amplifier output
is normal, if the amplifier power down or not when testing in this
case,there are several possibilities:
1. PM not allowed, domestic power meter can only test the equipment of
smaller output , can not test EDFA of higher output, the power meter of
testing optical amplifier must be imported, can't use the inaccurate
instrument as the standard.
2. The output port of flange is damaged, the possibility is small.
3. Improper use, plug when machine is working, burn the output fiber tip of
amplifier, cause the amplifier output power down, as this happens, just
re-welded to the optical amplifier output connector.
4. The pigtail of users is of poor quality,the core is too long, abrade the
output connector of amplifier after inserting pigtail, the phenomenon is
that the first test is good, the second time power is declined after
inserted into test again, the solution to this problem is as long as to
re-welding optical amplifier output connector.
5. The wavelength of light source is wrong, if the wavelength of 1550 nm
light transmitter has a deviation, can cause amplifier output power is not
enough, also can cause small panel displays.
6. Smaller light power of input optical amplifier, if it's lower than the
standard values may lead to smaller light power, and panel display will
be smaller.
Notes
1. Do not point the fiber output to the human body, especially the eyes, so
as to avoid damage.
2. Do not route connections in an energized state, so as to avoid improper
operation of output pigtail end face burns.
3. As the output power of the product is large, please pay attention to the
workshop temperature of the machine, keep good ventilation