Vous êtes sur la page 1sur 4

PROPOSED TWO-STOREY JAIME HILARIO INTEGRATED SCHOOL - LA

SALLE
DIVISION
6 - WOOD, PLASTICS AND COMPOSITES
SECTION 06 40 00
- Architectural Woodwork
June 2013

Project
:
Location :
DIVISION

Proposed Two-Storey Jaime Hilario Integrated School - La Salle


Banawang, Bagac, Bataan
6

SECTION 06 40 00
PART 1
1.1

1.2

WOOD, PLASTICS AND COMPOSITES


-

Architectural Woodwork

GENERAL

PROJECT INCLUDES:
A

Standing and running trim

Casework

Door frames and jambs (see section 08 14 00)

QUALITY ASSURANCE
A.

Conform to Architectural Woodwork Institute (AWI) - Architectural Woodwork


Quality Standards.

B.

Conform to Woodwork Institute of California (WIC) Manual of Millwork.

C.

Fire-retardant Treatment

Lumber: AWPA C20, non-corrosive interior type

Plywood: AWPA C27, non-corrosive interior type

Particleboard: ASTM E 84, flame spread 20 or less.

Fire retardant chemical shall provide protection against termites and fungal
decay, shall be registered for use as a wood preservative

Formaldehyde Emission Levels:

Particleboard:

Architectural Woodwork
06 40 00

NPA 8 compliance

Page 1 of 4

PROPOSED TWO-STOREY JAIME HILARIO INTEGRATED SCHOOL - LA


SALLE
DIVISION
6 - WOOD, PLASTICS AND COMPOSITES
SECTION 06 40 00
- Architectural Woodwork
June 2013

PART 2
2.1

High Density Fiberboard: NPA 9 compliance

Hardwood Plywood: HPMA FE Compliance

MATERIALS

PRODUCTS
A

Interior Standing and Running Trim


1

2
3
1
B

Interior Wood Casework

1
2
3
4
5
C

Tanguile / Narra
Grade: Premium

Auxiliary Materials

1
2
3
4
F

Hardware Standard: NSI / BHMA A 156.9


Hardware finish and base metal: Satin stainless steel
Glass: Clear float glass, ASTM C 1036

Interior frames and Jambs

1
2
E

Tanguile / Narra for transparent and opaque finish


Grade: Premium
Face Style: Flush
Frame Fabrication: Face Frame
Grain Matching: Vertical

Casework Hardware and Auxiliary Materials

1
2
3
D

Tanguile / Narra for Transparent / Opaque Finish


Grade: Premium
Baseboard: Provide for all floor and wall intersections as indicated on the
Drawings or as determined by the Project Manager. Tanguile baseboard.
Tanguile Cornices:

Screws: FS FF-S-111
Nails: FS FF-N-105
Anchors: Type required for secured anchorage
Provide all necessary hardware and fittings.

Factory Finishing
1

Transparent finish: Premium grade with dull-rubbed flat sheen

Architectural Woodwork
06 40 00

Page 2 of 4

PROPOSED TWO-STOREY JAIME HILARIO INTEGRATED SCHOOL - LA


SALLE
DIVISION
6 - WOOD, PLASTICS AND COMPOSITES
SECTION 06 40 00
- Architectural Woodwork
June 2013

EXECUTION

3.1

QUALITY LUMBER

3.2

Lumber shall be of approved quality of the respective kinds required for the various
parts of the work, well-seasoned, thoroughly dry and free from large, loose or
unsound knots, saps, shakes or other imperfections impairing its strength durability
or appearance.

Framing lumber shall be of rough dimensions shown on Drawings.

All exposed woodwork shall be smoothly dressed and well sand- papered.

SCHEDULE OF LUMBER
Use the following wood as required in the Drawings:
A

Yacal (kiln-dried)
1

Guijo (kiln-dried)
1

All frame work for double plywood partitions vertical and horizontal studs 50
mm x 76 mm, etc, where required.

Tanguile/Narra (Kiln-Dried)
1

All interior frame work for counters, cabinets, closets, and shelvings.

Doors, etc. (Verify door details)

4
3.3

For all door jambs and other wall openings with wood frames.

Apitong (pressure-treated with Copper Chromate Arsenic Salt Solution - CCA-C)


1

Wood plate and other lumber embedded or in contact with concrete, masonry or
plaster work, except those specified as pressure-treated with copper Chromate
Arsenic Salt Solution type-C.

All base board and other moulding requirements.

TREATMENT OF LUMBER
A

Lumber shall be well seasoned and kiln-dried to maximum moisture content of 15%
except Yacal which shall not be more than 12%.

Architectural Woodwork
06 40 00

Page 3 of 4

PROPOSED TWO-STOREY JAIME HILARIO INTEGRATED SCHOOL - LA


SALLE
DIVISION
6 - WOOD, PLASTICS AND COMPOSITES
SECTION 06 40 00
- Architectural Woodwork
June 2013

3.4

Lumber shall be pressure-treated with Copper Chromate Arsenic Salt Solution or


approved equal.
Accompany lumber with certificate from lumber company,
certifying treatment amount, moisture percentage after kiln-drying.

Surface in contact with masonry and concrete shall be coated with creosote.

PLYWOOD
A

3.5

3.6

Plywood Materials
1

All plywood shall be free from knots, splits and other open defects, with smooth
surface suitable to receive finish.

Marine, veneer plywood, 19 mm thick, three-ply Class C waterproofed for all


bathrooms flushed door. Refer to Section 08 14 00 Wood Door & Frames.

WORKMANSHIP
A.

Rough carpentry shall be executed in best, substantial, workmanlike manner.


Framing shall be erected true to line, levels and dimensions, squared, aligned,
plumbed, well spiked and nailed, adequately braced and fitted, using mortise and
tendon joints where practical.

B.

Millwork shall be accurately milled to details as approved in manner to allow free


play of panels, avoid swelling, shrinkage, insure work remaining in place without
warping, splitting, or opening of joints. Millwork shall not be installed until concrete
and masonry work have been cured and will not release moisture harmful to
woodwork.

HARDWARE INSTALLATION

Provide all necessary hardwares and fittings. Hardware shall be carefully fitted
and securely attached. Apply hardware in neat, workmanlike manner. Locks
shall be tested, knobs tightened, and necessary adjustments be made to put
entire job in good working order.

End of Section 06 40 00

Architectural Woodwork
06 40 00

Page 4 of 4