1. What is PUE, and why is it an important place to start when
considering how to reduce data center power consumption?
What value of PUE should data center managers strive for?
PUE = Power Use Effectiveness
It is the measure how effective you deliver power in cooling the IT equipment. And
also it is the ratio between the total facility energy and the IT equipment energy.
The place is important because the climate and weather factors help to the data
center to reduce power, for example some data centers that are in Belgium or in
other cold countries. They have to value the less amount, they explain that they
have a value of 2 and in a year they reach 1.16. Less is better.

2. Describe the five methods recommended by Google for reducing


power consumption.

Measure Pue
To manage the efficiency of a data center must have the tools to measure the
efficiency of energy use or PUE. It is a value that calculates the efficiency of the
power supply and cooling IT equipment
Manage Airflow
Once you can measure the PUE to reduce the energy load of the data center must
study the airflow. It is vital to remove the mixture of cold and hot air. Through
analysis of CFD (Computational Fluid Dynamics) the location of hot spots and the
direction of airflow in the data center is checked.
Model seeks to address better airflow.
Adjust Thermostat
Managed good airflow, you have to increase the temperature of the cold aisle.
Google increases the room temperature 22 to 27 degrees Celsius. This allows
significant savings in energy and that employees can go in shorts.
Utilize free cooling
When possible use the "free-cooling" system.

Andrea Altamirano
Gabriel Barragn J

Ambient temperature outside the data center is used to cool the room without using
equipment (chillers) energy intensive.
Optimize power distribution
To optimize the power distribution, power supplies Google uses high efficiency,
minimizes the number of times the power is converted from one to another type of
electrical power and maintaining power sources as close to the load. With UPS
losses. The normal are large battery rooms. But Google placed a battery on the
motherboard and conversion steps are eliminated and the CC goes directly to server
components.

3. Where do you suspect that data center power consumption will


be greatest: developing and emerging economies or alreadydeveloped economies. Why? (QUESTION 4)
The companies with the aim of reducing consumption, distributed data centers
around the world, in developed countries already and want to locate in areas with
low temperatures, cooling savings.
They are located in developed countries such as Iceland, Norway, Sweden, using
hydroelectric power and not coal or nuclear power.Also in the North American data
centers are located.