A) The CLARiiON storage system is based on a modular architecture. The first building block of
the architecture is the Disk Processor Enclosure, or DPE. The DPE houses the storage
Processor(s) and the first Fibre Channel Arbitrated Loop (FC-AL) disks. Disk Array Enclosures
(DAEs) are interconnected using Link Control Cards (LCCs).The module architecture allows the
customer to add drives as needed to meet capacity requirements. When more capacity is
required, additional disk array enclosures (DAE or DAE2) containing disk modules can be
easily added. LCC or Link Control Cards are used to connect shelves of disks. In addition, the
LCC monitors the FRUs within the shelf and reports status information to the storage
processor. The LCC contains bypass circuitry that allows continued operation of the loop in the
event of port failure.
Newer CLARiiON arrays have two processors per Storage Processor, and do not use
a DPE. Instead, it utilizes an SPE or Storage Processor Enclosure. The SPE does not contain
any disk modules, so it must have at least one DAE2 and a maximum of 16 DAE2s. CLARiiON
Architecture is based on intelligent Storage Processors that manage physical drives on the
back end and service host requests on the front end, be it Fibre Channel or iSCSI protocols.
Storage Processors communicate to each other over the CLARiiON Messaging Interface (CMI).
Both the front-end connection to the host and the back-end connection to the physical
storage is 2Gb Fibre channel.
2) What are the different types of Clariion?
A) CX-200,300,300i, 400,500,500i, 600 and 700.
17) How do you troubleshoot if the Hosts are not registering issue?
A) 1. Right click on clariion array and check the connectivity status whether the initiators are
showing. If it is showing check whether the initiators are logged in.
2. If it is showing under connectivity status and registered status showing "NO" then you need
to install Agent or else you need to register it manually.
3. If it is Registered and not logged in then you need to check the Zoning side and physical
connectivity.
4. if the host initiators are not showing under connectivity status at all then you need check the
zoning and physical connectivity. If possible remove the zone and create it back. Once you
create the zone dont forget to Enable and Save the config. After this just refresh it.
5. Once all these tasks are fine then you can login to Navisphere and update the array once.
Update is over then you can go to connectivity status and check.
CX____________________:0-4______________:6.22 GB
CX3___________________:0-4______________:33 GB
CX4___________________:0-4______________:62 GB
AX4-5_________________:0-3______________:17.4 GB
Vault Drives:
All Clariions have Vault Drives. They are the first five (5) disks in all Clariions. Disks 0_0_0
through 0_0_4. The Vault drives on the Clariion are going to contain some internal information
that is pre-configured before you start putting data on the Clariion. Vault Drives contains Vault
area, PSM Lun, Flare database Lun and Operating System.
The Vault:
The vault is a save area across the first five disks to store write cache from the Storage
Processors in the event of a Power Failure to the Clariion, or a Storage Processor Failure.
Operating System:
The Operating System of the Storage Processors is stored to the first five drives of the Clariion.